{"id":358,"date":"2016-04-14T00:00:00","date_gmt":"2016-04-13T15:00:00","guid":{"rendered":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/digitalpcr4\/"},"modified":"2025-07-01T16:56:11","modified_gmt":"2025-07-01T07:56:11","slug":"digitalpcr4","status":"publish","type":"post","link":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/digitalpcr4\/","title":{"rendered":"\u30c7\u30b8\u30bf\u30ebPCR\u306b\u3088\u308b\u6b21\u4e16\u4ee3\u30b7\u30fc\u30b1\u30f3\u30b5(NGS)\u306e\u30e9\u30a4\u30d6\u30e9\u30ea\u306e\u9ad8\u7cbe\u5ea6\u306a\u5b9a\u91cf"},"content":{"rendered":"<h2>\u30b7\u30f3\u30d7\u30eb\u3001\u6b63\u78ba\u3001\u304a\u624b\u9803\u306a\u30c7\u30b8\u30bf\u30ebPCR\u306b\u3088\u308bNGS\u30e9\u30a4\u30d6\u30e9\u30ea\u5b9a\u91cf<\/h2>\n<p><strong>\u30c7\u30b8\u30bf\u30ebPCR\u306f\u3001<a href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/life-science\/pcr\/digital-pcr\/quantstudio-3d-applications\/next-generation-sequencing-library-quantification.html?CID=gsd_pcr_sbu_r04_jp_cp0000_pjt0000_gsd00000_0so_blg_op_awa_oc_s00_qpcr38_Social_LAB\" target=\"_blank\" rel=\"noopener noreferrer\">NGS\u30e9\u30a4\u30d6\u30e9\u30ea\u5b9a\u91cf<\/a>\u3092\u30b7\u30f3\u30d7\u30eb\u304b\u3064\u6b63\u78ba\u306b\u884c\u3044\u3001\u30de\u30a4\u30af\u30ed\u30c1\u30c3\u30d7\u578b\u96fb\u6c17\u6cf3\u52d5\u3084\u5206\u5149\u5149\u5ea6\u8a08\u3068\u3044\u3063\u305f\u4ed6\u306e\u624b\u6cd5\u3092\u7528\u3044\u305f\u3068\u304d\u306b\u8d77\u3053\u308a\u304c\u3061\u306a\u3001\u30e9\u30a4\u30d6\u30e9\u30ea\u6fc3\u5ea6\u3092\u8aa4\u3063\u3066\u8a55\u4fa1\u3059\u308b\u53ef\u80fd\u6027\u3092\u8efd\u6e1b\u3057\u307e\u3059<\/strong>\u3002\u30c7\u30b8\u30bf\u30ebPCR\u306f\u3001\u3042\u308b\u30e9\u30a4\u30d6\u30e9\u30ea\u306b\u304a\u3044\u3066\u3001\u30d5\u30a9\u30ef\u30fc\u30c9\u3068\u30ea\u30d0\u30fc\u30b9\u30a2\u30c0\u30d7\u30bf\u30fc\u306e\u4e21\u65b9\u3092\u30ab\u30d0\u30fc\u3059\u308b\u3088\u3046\u306b\u30c7\u30b6\u30a4\u30f3\u3055\u308c\u305f\u7279\u7570\u6027\u306e\u9ad8\u3044\u30a2\u30c3\u30bb\u30a4\u3092\u4f7f\u7528\u3057\u3001\u4e21\u65b9\u306e\u30e9\u30a4\u30d6\u30e9\u30ea\u30a2\u30c0\u30d7\u30bf\u30fc\u914d\u5217\u3092\u542b\u3080\u69cb\u9020\u306e\u307f\u3092\u691c\u51fa\u3057\u307e\u3059\u3002<\/p>\n<div id=\"attachment_1109\" style=\"width: 486px\" class=\"wp-caption aligncenter\"><a href=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/digitalpcr4-fig1.jpg\" rel=\"attachment wp-att-1109\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-1109\" class=\"size-full wp-image-1109\" src=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/digitalpcr4-fig1.jpg\" alt=\"digitalpcr4-fig1\" width=\"476\" height=\"88\" \/><\/a><p id=\"caption-attachment-1109\" class=\"wp-caption-text\">\u56f31 NGS\u30e9\u30a4\u30d6\u30e9\u30ea\u5b9a\u91cf\u306b\u4f7f\u7528\u3059\u308b\u30a2\u30c3\u30bb\u30a4\u30c7\u30b6\u30a4\u30f3\u3002\u30d5\u30a9\u30ef\u30fc\u30c9\u30d7\u30e9\u30a4\u30de\u30fc\u3001\u30ea\u30d0\u30fc\u30b9\u30d7\u30e9\u30a4\u30de\u30fc\u3001\u30d7\u30ed\u30fc\u30d6\u3067\u69cb\u6210\u3002<\/p><\/div>\n<p>\u30c7\u30b8\u30bf\u30ebPCR\u306f\u6a19\u6e96\u66f2\u7dda\u3084\u30ea\u30d5\u30a1\u30ec\u30f3\u30b9\u30b5\u30f3\u30d7\u30eb\u3092\u4f7f\u7528\u305b\u305a\u3001NGS\u30e9\u30a4\u30d6\u30e9\u30ea\u3092\u6b63\u78ba\u306b\u5b9a\u91cf\u3067\u304d\u308b\u306e\u3067\u3001\u5b9f\u9a13\u306e\u624b\u9593\u3084\u5931\u6557\u306e\u30ea\u30b9\u30af\u3092\u6700\u5c0f\u9650\u306b\u6291\u3048\u3001\u30b7\u30fc\u30b1\u30f3\u30b7\u30f3\u30b0\u30ef\u30fc\u30af\u30d5\u30ed\u30fc\u306b\u304b\u304b\u308b\u30b3\u30b9\u30c8\u3092\u8efd\u6e1b\u3067\u304d\u307e\u3059\u3002<\/p>\n<p>\u307e\u305f\u3001\u30c7\u30b8\u30bf\u30ebPCR\u306f\u3001\u30b7\u30f3\u30d7\u30eb\u306a\u30ef\u30fc\u30af\u30d5\u30ed\u30fc\u306b\u3088\u308a\u3001\u308f\u305a\u304b\u6570\u6642\u9593\u3067\u30e9\u30a4\u30d6\u30e9\u30ea\u6fc3\u5ea6\u3092\u7cbe\u5bc6\u306b\u6e2c\u5b9a\u3067\u304d\u307e\u3059\u3002\u305d\u306e\u305f\u3081\u3001\u30e9\u30f3\u30cb\u30f3\u30b0\u306e\u3084\u308a\u76f4\u3057\u3084\u30b5\u30f3\u30d7\u30eb\u8abf\u88fd\u306e\u5931\u6557\u306e\u30ea\u30b9\u30af\u3092\u6700\u5c0f\u9650\u306b\u6291\u3048\u307e\u3059\u3002<strong>NGS\u30e9\u30a4\u30d6\u30e9\u30ea\u306e\u6fc3\u5ea6\u306f\u3001\u9ad8\u3059\u304e\u3066\u3082\u4f4e\u3059\u304e\u3066\u3082\u3001\u30c8\u30fc\u30bf\u30eb\u306e\u30ea\u30fc\u30c9\u6570\u306e\u6e1b\u5c11\u3001\u30c7\u30fc\u30bf\u53ce\u7387\u3084\u30b9\u30eb\u30fc\u30d7\u30c3\u30c8\u306e\u4f4e\u4e0b\u306b\u3064\u306a\u304c\u308a\u307e\u3059<\/strong>\u3002<\/p>\n<h2>\u3069\u306e\u3088\u3046\u306a\u3068\u304d\u306b\u30c7\u30b8\u30bf\u30ebPCR\u3092NGS\u30e9\u30a4\u30d6\u30e9\u30ea\u306e\u5b9a\u91cf\u306b\u4f7f\u7528\u3059\u308b\u304b<\/h2>\n<p>\u6a19\u6e96\u7684\u306a\u30e9\u30a4\u30d6\u30e9\u30ea\u306b\u306f\u5897\u5e45\u30b9\u30c6\u30c3\u30d7\u304c\u5fc5\u8981\u3067\u3059\u3002\u3053\u308c\u306b\u3088\u308a\u6b63\u3057\u304f\u4f5c\u88fd\u3055\u308c\u305f\u30e9\u30a4\u30d6\u30e9\u30ea(A\u304a\u3088\u3073B\u30a2\u30c0\u30d7\u30bf\u30fc\u306e\u4e21\u65b9\u306e\u914d\u5217\u3092\u542b\u3080\u30e9\u30a4\u30d6\u30e9\u30ea)\u304c\u6fc3\u7e2e\u3055\u308c\u307e\u3059\u3002\u5897\u5e45\u30b9\u30c6\u30c3\u30d7\u306f\u3001\u7dd1\u306e\u6955\u5186\u3067\u793a\u3059\u3088\u3046\u306aA\u3042\u308b\u3044\u306fB\u30a2\u30c0\u30d7\u30bf\u30fc\u306e\u7247\u65b9\u3057\u304b\u6301\u305f\u306a\u3044\u7121\u52b9\u306a\u30e9\u30a4\u30d6\u30e9\u30ea\u306e\u751f\u6210\u3092\u6700\u5c0f\u9650\u306b\u6291\u3048\u307e\u3059\u3002<strong>\u7121\u52b9\u306a\u30e9\u30a4\u30d6\u30e9\u30ea\u3068\u6709\u52b9\u306a\u30e9\u30a4\u30d6\u30e9\u30ea\u304c\u6df7\u5728\u3059\u308b\u4e2d\u3067\u3001\u5206\u5149\u5149\u5ea6\u8a08\u306a\u3069\u3067\u30e9\u30a4\u30d6\u30e9\u30ea\u6fc3\u5ea6\u306e\u5b9a\u91cf\u3092\u884c\u3046\u3053\u3068\u306f\u4e0d\u5341\u5206\u3068\u3044\u3048\u307e\u3059<\/strong>\u3002<br \/>\n<a href=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/digitalpcr4-fig2.jpg\" rel=\"attachment wp-att-1110\"><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter size-full wp-image-1110\" src=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/digitalpcr4-fig2.jpg\" alt=\"digitalpcr4-fig2\" width=\"542\" height=\"327\" \/><\/a><br \/>\n<strong>\u30c7\u30b8\u30bf\u30ebPCR\u306f\u3001\u7279\u306bPCR\u30b9\u30c6\u30c3\u30d7\u3092\u542b\u307e\u306a\u3044\u30d7\u30ed\u30c8\u30b3\u30fc\u30eb(Non-Standard Library)\u3067\u4f5c\u88fd\u3057\u305f\u30e9\u30a4\u30d6\u30e9\u30ea\u306e\u5b9a\u91cf\u306b\u7279\u306b\u6709\u52b9\u3067\u3059<\/strong>\u3002Non-Standard Library\u3067\u4f5c\u88fd\u3059\u308b\u3068\u3001\u7dd1\u306e\u6955\u5186\u3067\u793a\u3055\u308c\u3066\u3044\u308b\u3088\u3046\u306a\u3001\u7121\u52b9\u306a\u30e9\u30a4\u30d6\u30e9\u30ea\u306e\u5272\u5408\u304c\u3088\u308a\u9ad8\u304f\u306a\u308a\u307e\u3059\u3002<\/p>\n<p>Non-Standard Library\u306e\u30d7\u30ed\u30c8\u30b3\u30fc\u30eb\u3067\u4f5c\u88fd\u3055\u308c\u305f\u30e9\u30a4\u30d6\u30e9\u30ea\u306b\u304a\u3044\u3066\u3001\u5897\u5e45\u30b9\u30c6\u30c3\u30d7\u306f\u3001\u6b63\u3057\u304f\u4f5c\u88fd\u3055\u308c\u305f\u30e9\u30a4\u30d6\u30e9\u30ea\u306e\u6fc3\u7e2e\u306b\u6709\u7528\u3067\u3059\u3002<strong>\u73fe\u5728\u3001NGS\u30e9\u30a4\u30d6\u30e9\u30ea\u306e\u5b9a\u91cf\u306b\u4f7f\u7528\u3055\u308c\u3066\u3044\u308b\u65b9\u6cd5\u3068\u3057\u3066\u306f\u3001\u5206\u5149\u5149\u5ea6\u6cd5\u3084qPCR\u6cd5\u306a\u3069\u304c\u3042\u308a\u307e\u3059<\/strong>\u3002<\/p>\n<p>\u5206\u5149\u5149\u5ea6\u6cd5\u306f\u3001\u9577\u3044\u9593DNA\u3084RNA\u306e\u5b9a\u91cf\u306b\u4f7f\u7528\u3055\u308c\u3066\u304d\u307e\u3057\u305f\u3002\u3057\u304b\u3057\u3001\u7d2b\u5916\u7dda\u5438\u5149\u5ea6\u6cd5\u306b\u3088\u308b\u6e2c\u5b9a\u306f\u7279\u7570\u7684\u3067\u306f\u306a\u304f\u3001DNA\u3001RNA\u3001\u30bf\u30f3\u30d1\u30af\u8cea\u306e\u9593\u306e\u533a\u5225\u304c\u3067\u304d\u307e\u305b\u3093\u3002\u307e\u305f\u6e2c\u5b9a\u5024\u306f\u3001\u904a\u96e2\u30cc\u30af\u30ec\u30aa\u30c1\u30c9\u3001\u5869\u3001\u30a8\u30bf\u30ce\u30fc\u30eb\u3084\u30d5\u30a7\u30ce\u30fc\u30eb\u306a\u3069\u306e\u6709\u6a5f\u7269\u3084\u5869\u57fa\u7d44\u6210\u306e\u3070\u3089\u3064\u304d\u306a\u3069\u306b\u5f71\u97ff\u3092\u53d7\u3051\u3001\u5b9f\u969b\u306e\u6fc3\u5ea6\u3088\u308a\u9ad8\u3044\u6fc3\u5ea6\u304c\u793a\u3055\u308c\u308b\u5834\u5408\u304c\u3042\u308a\u307e\u3059\u3002<strong>\u5206\u5149\u5149\u5ea6\u8a08\u306e\u611f\u5ea6\u306f\u3001\u4f4e\u6fc3\u5ea6\u306eDNA\u3084RNA\u5b9a\u91cf\u306b\u304a\u3044\u3066\u591a\u304f\u306e\u5834\u5408\u4e0d\u5341\u5206\u3067\u3059<\/strong>\u3002<\/p>\n<p><strong>\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR \u306f\u3001NGS\u306e\u30e9\u30a4\u30d6\u30e9\u30ea\u5b9a\u91cf\u3092\u884c\u3046\u6709\u7528\u306a\u65b9\u6cd5\u3067\u3059\u304c\u3001\u30ea\u30d5\u30a1\u30ec\u30f3\u30b9\u30b5\u30f3\u30d7\u30eb\u3084\u6a19\u6e96\u66f2\u7dda\u306e\u4f5c\u6210\u304c\u5fc5\u8981\u3067\u3059<\/strong>\u3002\u30b9\u30eb\u30fc\u30d7\u30c3\u30c8\u304c\u6c42\u3081\u3089\u308c\u308b\u7814\u7a76\u5ba4\u3067\u3001\u7570\u306a\u308b\u7a2e\u985e\u306e\u30e9\u30a4\u30d6\u30e9\u30ea\u3092\u4e26\u884c\u3057\u3066\u30b7\u30fc\u30b1\u30f3\u30b9\u3092\u884c\u3046\u5834\u5408\u3001\u8907\u6570\u306e\u6a19\u6e96\u66f2\u7dda\u3092\u4f5c\u6210\u3059\u308b\u5fc5\u8981\u304c\u3042\u308a\u307e\u3059\u304c\u3001\u4f5c\u696d\u304c\u7169\u96d1\u306b\u306a\u308a\u3001\u30b3\u30b9\u30c8\u3084\u6240\u8981\u6642\u9593\u304c\u5897\u3048\u3001\u30a8\u30e9\u30fc\u306e\u53ef\u80fd\u6027\u3092\u9ad8\u3081\u308b\u53ef\u80fd\u6027\u304c\u3042\u308a\u307e\u3059\u3002<\/p>\n<p><strong>1\u3064\u306e\u5927\u304d\u306a\u6f5c\u5728\u7684\u30a8\u30e9\u30fc\u3068\u3057\u3066\u306f\u3001<a href=\"http:\/\/www.ncbi.nlm.nih.gov\/pmc\/articles\/PMC1317340\/\" target=\"_blank\" rel=\"noopener noreferrer\">PCR\u30d0\u30a4\u30a2\u30b9<\/a>\u304c\u3042\u308a\u307e\u3059<\/strong>\u3002\u3053\u308c\u306f\u3001\u30c6\u30f3\u30d7\u30ec\u30fc\u30c8\u306e\u5897\u5e45\u52b9\u7387\u306e\u5dee\u3084PCR\u306e\u5f8c\u534a\u306b\u751f\u3058\u308b\u5897\u5e45\u7523\u7269\u306b\u3088\u308b\u963b\u5bb3\u3067\u3059\u3002\u591a\u304f\u306e\u30d7\u30ed\u30c8\u30b3\u30fc\u30eb\u3067\u306f\u3001PCR\u30d0\u30a4\u30a2\u30b9\u3092\u907f\u3051\u308b\u305f\u3081\u306b\u5897\u5e45\u3092\u884c\u308f\u306a\u3044\u50be\u5411\u306b\u3042\u308a\u3001\u3053\u308c\u304c\u6b63\u3057\u304f\u4f5c\u88fd\u3055\u308c\u308b\u30e9\u30a4\u30d6\u30e9\u30ea\u306e\u5272\u5408\u306e\u4f4e\u4e0b\u306b\u3064\u306a\u304c\u3063\u3066\u3044\u307e\u3059\u3002<\/p>\n<p>\u7279\u306b\u3001\u5206\u5149\u5149\u5ea6\u8a08\u306f\u3001\u6b63\u3057\u304f\u4f5c\u88fd\u3055\u308c\u305f\u30e9\u30a4\u30d6\u30e9\u30ea\u3068\u6b63\u3057\u304f\u4f5c\u88fd\u3055\u308c\u306a\u304b\u3063\u305f\u30e9\u30a4\u30d6\u30e9\u30ea\u306e\u4e21\u65b9\u3092\u691c\u51fa\u3059\u308b\u305f\u3081\u3001\u30e9\u30a4\u30d6\u30e9\u30ea\u6fc3\u5ea6\u304c\u904e\u5927\u8a55\u4fa1\u3055\u308c\u308b\u53ef\u80fd\u6027\u304c\u3042\u308a\u307e\u3059\u3002<\/p>\n<p><strong><a href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/life-science\/pcr\/digital-pcr.html?CID=gsd_pcr_sbu_r04_jp_cp0000_pjt0000_gsd00000_0so_blg_op_awa_oc_s00_qpcr38_Social_LAB\" target=\"_blank\" rel=\"noopener noreferrer\">Applied biosystems\u2122 QuantStudio\u2122 3D \u30c7\u30b8\u30bf\u30ebPCR\u30b7\u30b9\u30c6\u30e0<\/a>\u3092\u3001Ion Torrent\u2122\u3001\u3042\u308b\u3044\u306fIllumina\u00ae \u30e9\u30a4\u30d6\u30e9\u30ea\u5b9a\u91cf\u7528\u306eTaqMan\u2122 \u30a2\u30c3\u30bb\u30a4\u3068\u3068\u3082\u306b\u3054\u5229\u7528\u3044\u3044\u305f\u3060\u304f\u3068\u3001\u6b63\u3057\u304f\u4f5c\u88fd\u3055\u308c\u305f\u30e9\u30a4\u30d6\u30e9\u30ea\u306e\u307f\u3092\u691c\u51fa\u3067\u304d\u308b\u306e\u3067\u3001\u6fc3\u5ea6\u306e\u904e\u5927\u8a55\u4fa1\u306e\u554f\u984c\u3092\u8efd\u6e1b\u3057\u3001\u7cbe\u5bc6\u306a\u30e9\u30a4\u30d6\u30e9\u30ea\u5b9a\u91cf\u304c\u53ef\u80fd\u3067\u3059<\/strong>\u3002\u6b63\u78ba\u30fb\u7cbe\u5bc6\u306aNGS\u30e9\u30a4\u30d6\u30e9\u30ea\u306e\u5b9a\u91cf\u306f\u3001\u30b7\u30fc\u30b1\u30f3\u30b7\u30f3\u30b0\u30c7\u30fc\u30bf\u306e\u53ce\u7387\u3092\u6700\u5927\u5316\u3059\u308b\u305f\u3081\u306b\u3082\u3001<a href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/life-science\/sequencing\/next-generation-sequencing\/ion-torrent-next-generation-sequencing-workflow\/ion-torrent-next-generation-sequencing-run-sequence\/ion-pgm-system-for-next-generation-sequencing.html#simplest?CID=gsd_pcr_sbu_r04_jp_cp0000_pjt0000_gsd00000_0so_blg_op_awa_oc_s00_qpcr38_Social_LAB\" target=\"_blank\" rel=\"noopener noreferrer\">Ion Torrent\u2122\u3084\u4ed6\u306eNGS\u30ef\u30fc\u30af\u30d5\u30ed\u30fc<\/a>\u306b\u304a\u3044\u3066\u3082\u91cd\u8981\u306a\u30b9\u30c6\u30c3\u30d7\u3067\u3059\u3002<\/p>\n<h2><a href=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-content\/uploads\/2016\/12\/Precise_quantification_of_Ion_Torrent_libraries_on_QS3D.pdf\" target=\"_blank\" rel=\"noopener noreferrer\">QuantStudio\u2122 3D\u3092\u7528\u3044\u305f Ion Torrent\u2122 NGS\u30e9\u30a4\u30d6\u30e9\u30ea\u306e\u7cbe\u5bc6\u306a\u5b9a\u91cf<\/a><\/h2>\n<p><strong>Ion Torrent \u30d7\u30e9\u30c3\u30c8\u30d5\u30a9\u30fc\u30e0\u306a\u3069\u3092\u7528\u3044\u305fNGS\u30ef\u30fc\u30af\u30d5\u30ed\u30fc\u306e\u4e2d\u3067\u3001\u30c6\u30f3\u30d7\u30ec\u30fc\u30c8\u8abf\u88fd\u30b9\u30c6\u30c3\u30d7\u306f\u3001\u30b7\u30fc\u30b1\u30f3\u30b7\u30f3\u30b0\u306e\u53ce\u7387\u3092\u6700\u9069\u5316\u3059\u308b\u305f\u3081\u306b\u91cd\u8981\u3067\u3059<\/strong>\u3002\u3053\u306e\u30b9\u30c6\u30c3\u30d7\u306f\u30e9\u30a4\u30d6\u30e9\u30ea\u306e\u30a4\u30f3\u30d7\u30c3\u30c8\u91cf\u306b\u5927\u304d\u304f\u5de6\u53f3\u3055\u308c\u307e\u3059\u3002\u30e9\u30a4\u30d6\u30e9\u30ea\u6fc3\u5ea6\u304c\u9ad8\u3059\u304e\u3066\u3082\u4f4e\u3059\u304e\u3066\u3082\u3001\u30c8\u30fc\u30bf\u30eb\u306e\u30ea\u30fc\u30c9\u6570\u304a\u3088\u3073\u30b9\u30eb\u30fc\u30d7\u30c3\u30c8\u306b\u30de\u30a4\u30ca\u30b9\u306e\u5f71\u97ff\u3092\u53ca\u307c\u3057\u307e\u3059\u3002<\/p>\n<div id=\"attachment_1112\" style=\"width: 917px\" class=\"wp-caption aligncenter\"><a href=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/digitalpcr4-fig3.jpg\" rel=\"attachment wp-att-1112\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-1112\" class=\"size-full wp-image-1112\" src=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/digitalpcr4-fig3.jpg\" alt=\"digitalpcr4-fig3\" width=\"907\" height=\"296\" \/><\/a><p id=\"caption-attachment-1112\" class=\"wp-caption-text\">\u56f33 Ion OneTouch\u2122 2 \u30b7\u30b9\u30c6\u30e0\u3067\u30c6\u30f3\u30d7\u30ec\u30fc\u30c8\u3092\u8abf\u6574\u3059\u308b\u524d\u306b\u3001QuantStudio 3D\u3067NGS\u30e9\u30a4\u30d6\u30e9\u30ea\u3092\u6b63\u78ba\u306b\u5b9a\u91cf\u3059\u308bNGS\u30ef\u30fc\u30af\u30d5\u30ed\u30fc<\/p><\/div>\n<p>QuantStudio 3D \u30c7\u30b8\u30bf\u30ebPCR\u30b7\u30b9\u30c6\u30e0\u3067\u306f\u3001PCR\u53cd\u5fdc\u6db2(\u5e0c\u91c8\u3057\u305f\u30b5\u30f3\u30d7\u30eb+ QuantStudio 3D dPCR Master Mix + <a href=\"http:\/\/www.thermofisher.com\/jp\/ja\/home\/life-science\/sequencing\/dna-sequencing\/targeted-sequencing\/targeted-sequencing-ion-torrent-next-generation-sequencing.html?CID=gsd_pcr_sbu_r04_jp_cp0000_pjt0000_gsd00000_0so_blg_op_awa_oc_s00_qpcr38_Social_LAB\" target=\"_blank\" rel=\"noopener noreferrer\">TaqMan\u30a2\u30c3\u30bb\u30a4<\/a>)\u3092\u300120,000\u500b\u306e\u30a6\u30a7\u30eb\u3092\u6301\u3064\u30c1\u30c3\u30d7\u306b\u5206\u914d\u3057\u5bc6\u9589\u3057\u307e\u3059\u3002\u30bf\u30fc\u30b2\u30c3\u30c8\u5206\u5b50\u306e1\u30b3\u30d4\u30fc\u304c1\u30a6\u30a7\u30eb\u306b\u542b\u3080\u304b\u542b\u307e\u306a\u3044\u3088\u3046\u306b\u3001\u30b5\u30f3\u30d7\u30eb\u3092\u6700\u521d\u306b\u5e0c\u91c8\u3057\u3001\u30c7\u30e5\u30a2\u30eb\u30d5\u30e9\u30c3\u30c8\u30d6\u30ed\u30c3\u30af\u306e\u30b5\u30fc\u30de\u30eb\u30b5\u30a4\u30af\u30e9\u2015\u3067\u5897\u5e45\u3092\u884c\u3044\u307e\u3059\u3002\u30bf\u30fc\u30b2\u30c3\u30c8\u5206\u5b50\u304c\u542b\u3080\u30a6\u30a7\u30eb\u306f\u30dd\u30b8\u30c6\u30a3\u30d6\u53cd\u5fdc\u3001\u542b\u307e\u306a\u3044\u30a6\u30a7\u30eb\u306f\u30cd\u30ac\u30c6\u30a3\u30d6\u53cd\u5fdc\u3068\u306a\u308a\u3001\u30cd\u30ac\u30c6\u30a3\u30d6\u53cd\u5fdc\u306e\u30a6\u30a7\u30eb\u306e\u5272\u5408\u3092\u7528\u3044\u3066\u30b5\u30f3\u30d7\u30eb\u4e2d\u306e\u30bf\u30fc\u30b2\u30c3\u30c8\u5206\u5b50\u3092\u5b9a\u91cf\u3057\u307e\u3059\u3002<\/p>\n<div id=\"attachment_1114\" style=\"width: 762px\" class=\"wp-caption aligncenter\"><a href=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/digitalpcr4-fig4.jpg\" rel=\"attachment wp-att-1114\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-1114\" class=\"size-full wp-image-1114\" src=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/digitalpcr4-fig4.jpg\" alt=\"digitalpcr4-fig4\" width=\"752\" height=\"199\" \/><\/a><p id=\"caption-attachment-1114\" class=\"wp-caption-text\">\u56f34 QuantStudio 3D\u3068Ion OneTouch 2\u30c7\u30fc\u30bf\u306e\u76f8\u95a2\u95a2\u4fc2\u3002\u3053\u306eQC\u30c7\u30fc\u30bf\u306f\u3001\u6fc3\u7e2e\u524d\u306b4\u7a2e\u985e\u306e Ion Torrent \u30e9\u30a4\u30d6\u30e9\u30ea\u306b\u3064\u3044\u3066\u30d5\u30ed\u30fc\u30b5\u30a4\u30c8\u30e1\u30c8\u30ea\u30fc\u3092\u7528\u3044\u3066\u751f\u6210\u3002<\/p><\/div>\n<p><strong>\u7d76\u5bfe\u5b9a\u91cf<\/strong>: \u6700\u7d42\u7684\u306a\u30e9\u30a4\u30d6\u30e9\u30ea\u6fc3\u5ea6\u3092\u6c42\u3081\u308b\u524d\u306b\u3001\u30e9\u30a4\u30d6\u30e9\u30ea\u30b5\u30f3\u30d7\u30eb\u306e\u5e0c\u91c8\u7387\u3068\u53cd\u5fdc\u6db2\u306e\u8abf\u5408\u6642(\u30c1\u30c3\u30d7\u4e0a\u3067\u306e)\u306e\u5e0c\u91c8\u7387\u306b\u57fa\u3065\u3044\u3066\u30c7\u30fc\u30bf\u3092\u8abf\u6574\u3057\u306a\u3051\u308c\u3070\u306a\u308a\u307e\u305b\u3093\u3002 \u3053\u306e\u30d7\u30ed\u30bb\u30b9\u306f\u3001<a href=\"http:\/\/www.thermofisher.com\/jp\/ja\/home\/life-science\/pcr\/digital-pcr\/quantstudio-3d-digital-pcr-system\/quantstudio-3d-software.html?CID=gsd_pcr_sbu_r04_jp_cp0000_pjt0000_gsd00000_0so_blg_op_awa_oc_s00_qpcr38_Social_LAB\" target=\"_blank\" rel=\"noopener noreferrer\">QuantStudio\u2122 3D AnalysisSuite\u2122 Cloud \u30bd\u30d5\u30c8\u30a6\u30a7\u30a2<\/a>\u3092\u3054\u5229\u7528\u3044\u3044\u305f\u3060\u3051\u307e\u3059\u3002<\/p>\n<p>\u76f8\u95a2: Ion OneTouch 2 \u30b7\u30b9\u30c6\u30e0\u3067\u30c6\u30f3\u30d7\u30ec\u30fc\u30c8\u30d3\u30fc\u30ba\u3092\u8abf\u88fd\u3059\u308b\u305f\u3081\u306b\u306f\u3001\u6fc3\u5ea6\u8a08\u7b97\u5024 (nM) \u306b\u57fa\u3065\u3044\u3066\u30e9\u30a4\u30d6\u30e9\u30ea\u3092\u5e0c\u91c8\u3059\u308b\u5fc5\u8981\u304c\u3042\u308a\u307e\u3059\u3002\u30a8\u30f3\u30ea\u30c3\u30c1\u30e1\u30f3\u30c8\u3092\u884c\u3046\u524d\u306b\u3001<a href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/industrial\/spectroscopy-elemental-isotope-analysis\/molecular-spectroscopy\/fluorometers\/qubit\/models\/qubit-4.html\n?CID=gsd_pcr_sbu_r04_jp_cp0000_pjt0000_gsd00000_0so_blg_op_awa_oc_s00_qpcr38_Social_LAB\" target=\"_blank\" rel=\"noopener noreferrer\">Qubit\u00ae 3.0 Fluorometer<\/a>\u3092\u4f7f\u7528\u3057\u3066\u3001\u30b5\u30f3\u30d7\u30eb\u4e2d\u3067\u751f\u6210\u3055\u308c\u305f\u30c6\u30f3\u30d7\u30ec\u30fc\u30c8\u30d3\u30fc\u30ba\u306e\u54c1\u8cea\u3092\u8a55\u4fa1\u3059\u308b\u305f\u3081\u306b\u54c1\u8cea\u7ba1\u7406\u306e\u30b9\u30c6\u30c3\u30d7\u304c\u5fc5\u8981\u3067\u3059\u3002\u30d3\u30fc\u30ba\u306e10\uff5e30%\u304c\u5897\u5e45\u30c6\u30f3\u30d7\u30ec\u30fc\u30c8\u3068\u7d50\u5408\u3059\u308b\u3088\u3046\u306b\u30e9\u30a4\u30d6\u30e9\u30ea\u3092\u5e0c\u91c8\u3057\u305f\u3068\u304d\u306b\u3001\u6700\u9069\u306a\u30e9\u30a4\u30d6\u30e9\u30ea\u5b9a\u91cf\u304c\u3067\u304d\u307e\u3059\u3002\u3053\u306e\u63a8\u5968\u7bc4\u56f2\u5185\u306b\u5165\u308b\u30b5\u30f3\u30d7\u30eb\u304b\u3089\u306f\u3001\u304a\u304a\u3080\u306d\u8cea\u306e\u9ad8\u3044\u30c7\u30fc\u30bf\u304c\u5f97\u3089\u308c\u307e\u3059\u3002<\/p>\n<h2>\u307e\u3068\u3081<\/h2>\n<p>\u6700\u9069\u306aNGS\u30c7\u30fc\u30bf\u53ce\u7387\u3092\u5f97\u308b\u306b\u306f\u3001\u8cea\u306e\u9ad8\u3044\u30c6\u30f3\u30d7\u30ec\u30fc\u30c8\u8abf\u88fd\u304c\u5fc5\u8981\u3067\u3059\u3002<strong>\u30c7\u30b8\u30bf\u30ebPCR\u3067\u30e9\u30a4\u30d6\u30e9\u30ea\u5b9a\u91cf\u3092\u884c\u3046\u3053\u3068\u3067\u3001\u30b7\u30fc\u30b1\u30f3\u30b7\u30f3\u30b0\u306b\u304b\u304b\u308b\u5168\u4f53\u7684\u306a\u30b3\u30b9\u30c8\u306e\u524a\u6e1b\u306b\u3064\u306a\u304c\u308a\u307e\u3059<\/strong>\u3002\u305d\u308c\u306f\u3001\u30c0\u30a6\u30f3\u30b9\u30c8\u30ea\u30fc\u30e0\u3067\u306e\u8ffd\u52a0\u4f5c\u696d\u3084\u30b9\u30c6\u30c3\u30d7\u306e\u7e70\u308a\u8fd4\u3057\u3092\u56de\u907f\u3057\u3001\u30b7\u30fc\u30b1\u30f3\u30b9\u306e\u54c1\u8cea\u3092\u78ba\u4fdd\u3067\u304d\u308b\u304b\u3089\u3067\u3059\u3002<strong>QuantStudio 3D\u30c7\u30b8\u30bf\u30ebPCR\u30b7\u30b9\u30c6\u30e0\u3068\u30e9\u30a4\u30d6\u30e9\u30ea\u306b\u7279\u7570\u7684\u306aTaqMan\u30a2\u30c3\u30bb\u30a4\u306f\u3001\u30b5\u30f3\u30d7\u30eb\u306e\u53d6\u6271\u3044\u306b\u304b\u304b\u308b\u624b\u9593\u3092\u6700\u5c0f\u9650\u306b\u6291\u3048\u3001\u6a19\u6e96\u66f2\u7dda\u3084\u30ea\u30d5\u30a1\u30ec\u30f3\u30b9\u30b5\u30f3\u30d7\u30eb\u3092\u4f7f\u7528\u3059\u308b\u3053\u3068\u306a\u304f\u3001\u9ad8\u7cbe\u5ea6\u306e\u30c6\u30f3\u30d7\u30ec\u30fc\u30c8\u8abf\u88fd\u3092\u5b9f\u73fe\u3057\u305f\u3001\u304a\u624b\u9803\u3067\u4f7f\u3044\u6613\u3044\u30c7\u30b8\u30bf\u30ebPCR\u6cd5\u3092\u63d0\u4f9b\u3057\u307e\u3059\u3002<\/strong><\/p>\n<h3>\u3010\u7121\u6599\u30c0\u30a6\u30f3\u30ed\u30fc\u30c9\u3011\u30c7\u30b8\u30bf\u30ebPCR\u30a2\u30d7\u30ea\u30b1\u30fc\u30b7\u30e7\u30f3\u30ac\u30a4\u30c9<\/h3>\n<p>\u30c7\u30b8\u30bf\u30ebPCR\u306b\u3088\u308b\u5b9a\u91cf\u304c\u6709\u7528\u306a\u8907\u6570\u306e\u30a2\u30d7\u30ea\u30b1\u30fc\u30b7\u30e7\u30f3\u306b\u3064\u3044\u3066\u7d39\u4ecb\u3057\u3066\u3044\u307e\u3059\u3002\u3053\u308c\u304b\u3089\u30c7\u30b8\u30bf\u30ebPCR\u5b9f\u9a13\u3092\u8003\u3048\u3066\u3044\u308b\u65b9\u306b\u6700\u9069\u3067\u3059\u3002<\/p>\n<p><a class=\"btn btn-red\" href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/global\/forms\/life-science\/dpcr-applications-ebook-jp.html?CID=gsd_pcr_sbu_r04_jp_cp0000_pjt0000_gsd00000_0so_blg_op_awa_oc_s00_qpcr38_Social_LAB\" target=\"_blank\" rel=\"noopener\">\u30c0\u30a6\u30f3\u30ed\u30fc\u30c9\u306f\u3053\u3061\u3089<\/a><br \/>\n&nbsp;<\/p>\n<p>\u7814\u7a76\u7528\u306b\u306e\u307f\u4f7f\u7528\u3067\u304d\u307e\u3059\u3002\u8a3a\u65ad\u7528\u306b\u306f\u4f7f\u7528\u3044\u305f\u3060\u3051\u307e\u305b\u3093\u3002<\/p>\n","protected":false},"excerpt":{"rendered":"<p>\u30c7\u30b8\u30bf\u30ebPCR (dPCR) \u3092\u7d39\u4ecb\u3057\u3066\u3044\u308b6\u90e8\u69cb\u6210\u30b7\u30ea\u30fc\u30ba\u306e\u30d1\u30fc\u30c84\u3068\u3057\u3066\u3001\u4eca\u56de\u306f\u3001\u30c7\u30b8\u30bf\u30ebPCR\u306b\u3088\u308b\u6b21\u4e16\u4ee3\u30b7\u30fc\u30b1\u30f3\u30b5(NGS)\u306e\u30e9\u30a4\u30d6\u30e9\u30ea\u306e\u9ad8\u7cbe\u5ea6\u306a\u5b9a\u91cf\u306b\u3064\u3044\u3066\u3054\u7d39\u4ecb\u3057\u307e\u3059\u3002\u30c7\u30b8\u30bf\u30ebPCR\u306f\u3001NGS\u30e9\u30a4\u30d6\u30e9\u30ea\u5b9a\u91cf\u3092\u30b7\u30f3\u30d7\u30eb\u304b\u3064\u6b63\u78ba\u306b\u884c\u3044\u3001\u30de\u30a4\u30af\u30ed\u30c1\u30c3\u30d7\u578b\u96fb\u6c17\u6cf3\u52d5\u3084\u5206\u5149\u5149\u5ea6\u8a08\u3068\u3044\u3063\u305f\u4ed6\u306e\u624b\u6cd5\u3092\u7528\u3044\u305f\u3068\u304d\u306b\u8d77\u3053\u308a\u304c\u3061\u306a\u3001\u30e9\u30a4\u30d6\u30e9\u30ea\u6fc3\u5ea6\u3092\u8aa4\u3063\u3066\u8a55\u4fa1\u3059\u308b\u53ef\u80fd\u6027\u3092\u8efd\u6e1b\u3057\u307e\u3059\u3002<\/p>\n","protected":false},"author":988,"featured_media":2574,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_monsterinsights_skip_tracking":false,"_genesis_hide_title":false,"_genesis_hide_breadcrumbs":false,"_genesis_hide_singular_image":false,"_genesis_hide_footer_widgets":false,"_genesis_custom_body_class":"","_genesis_custom_post_class":"","_genesis_layout":"","_jetpack_newsletter_access":"","_jetpack_dont_email_post_to_subs":false,"_jetpack_newsletter_tier_id":0,"_jetpack_memberships_contains_paywalled_content":false,"_jetpack_feature_clip_id":0,"_jetpack_memberships_contains_paid_content":false,"footnotes":"","jetpack_post_was_ever_published":false},"categories":[156],"tags":[44],"division":[],"class_list":{"0":"post-358","1":"post","2":"type-post","3":"status-publish","4":"format-standard","5":"has-post-thumbnail","7":"category-mol-bio","8":"tag-digital-pcr","9":"entry"},"_selected_authors":[],"_selected_reviewers":[],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v27.8 (Yoast SEO v27.8) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>\u30c7\u30b8\u30bf\u30ebPCR\u306b\u3088\u308b\u6b21\u4e16\u4ee3\u30b7\u30fc\u30b1\u30f3\u30b5(NGS)\u306e\u30e9\u30a4\u30d6\u30e9\u30ea\u306e\u9ad8\u7cbe\u5ea6\u306a\u5b9a\u91cf - Learning at the Bench<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/digitalpcr4\/\" \/>\n<meta property=\"og:locale\" content=\"ja_JP\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"\u30c7\u30b8\u30bf\u30ebPCR\u306b\u3088\u308b\u6b21\u4e16\u4ee3\u30b7\u30fc\u30b1\u30f3\u30b5(NGS)\u306e\u30e9\u30a4\u30d6\u30e9\u30ea\u306e\u9ad8\u7cbe\u5ea6\u306a\u5b9a\u91cf\" \/>\n<meta property=\"og:description\" content=\"\u30c7\u30b8\u30bf\u30ebPCR (dPCR) \u3092\u7d39\u4ecb\u3057\u3066\u3044\u308b6\u90e8\u69cb\u6210\u30b7\u30ea\u30fc\u30ba\u306e\u30d1\u30fc\u30c84\u3068\u3057\u3066\u3001\u4eca\u56de\u306f\u3001\u30c7\u30b8\u30bf\u30ebPCR\u306b\u3088\u308b\u6b21\u4e16\u4ee3\u30b7\u30fc\u30b1\u30f3\u30b5(NGS)\u306e\u30e9\u30a4\u30d6\u30e9\u30ea\u306e\u9ad8\u7cbe\u5ea6\u306a\u5b9a\u91cf\u306b\u3064\u3044\u3066\u3054\u7d39\u4ecb\u3057\u307e\u3059\u3002\u30c7\u30b8\u30bf\u30ebPCR\u306f\u3001NGS\u30e9\u30a4\u30d6\u30e9\u30ea\u5b9a\u91cf\u3092\u30b7\u30f3\u30d7\u30eb\u304b\u3064\u6b63\u78ba\u306b\u884c\u3044\u3001\u30de\u30a4\u30af\u30ed\u30c1\u30c3\u30d7\u578b\u96fb\u6c17\u6cf3\u52d5\u3084\u5206\u5149\u5149\u5ea6\u8a08\u3068\u3044\u3063\u305f\u4ed6\u306e\u624b\u6cd5\u3092\u7528\u3044\u305f\u3068\u304d\u306b\u8d77\u3053\u308a\u304c\u3061\u306a\u3001\u30e9\u30a4\u30d6\u30e9\u30ea\u6fc3\u5ea6\u3092\u8aa4\u3063\u3066\u8a55\u4fa1\u3059\u308b\u53ef\u80fd\u6027\u3092\u8efd\u6e1b\u3057\u307e\u3059\u3002\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/digitalpcr4\/\" \/>\n<meta property=\"og:site_name\" content=\"Learning at the Bench\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/ThermoFisherJapan\" \/>\n<meta property=\"article:published_time\" content=\"2016-04-13T15:00:00+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2025-07-01T07:56:11+00:00\" \/>\n<meta property=\"og:image\" content=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/digitalpcr-title-3.jpeg\" \/>\n\t<meta property=\"og:image:width\" content=\"600\" \/>\n\t<meta property=\"og:image:height\" content=\"315\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"LATB Staff\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:creator\" content=\"@ThermoFisherJP\" \/>\n<meta name=\"twitter:site\" content=\"@ThermoFisherJP\" \/>\n<meta name=\"twitter:label1\" content=\"\u57f7\u7b46\u8005\" \/>\n\t<meta name=\"twitter:data1\" content=\"LATB Staff\" \/>\n\t<meta name=\"twitter:label2\" content=\"\u63a8\u5b9a\u8aad\u307f\u53d6\u308a\u6642\u9593\" \/>\n\t<meta name=\"twitter:data2\" content=\"11\u5206\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/digitalpcr4\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/digitalpcr4\\\/\"},\"author\":{\"name\":\"LATB Staff\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#\\\/schema\\\/person\\\/00a095a01d54afcdf9457465feb04f7d\"},\"headline\":\"\u30c7\u30b8\u30bf\u30ebPCR\u306b\u3088\u308b\u6b21\u4e16\u4ee3\u30b7\u30fc\u30b1\u30f3\u30b5(NGS)\u306e\u30e9\u30a4\u30d6\u30e9\u30ea\u306e\u9ad8\u7cbe\u5ea6\u306a\u5b9a\u91cf\",\"datePublished\":\"2016-04-13T15:00:00+00:00\",\"dateModified\":\"2025-07-01T07:56:11+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/digitalpcr4\\\/\"},\"wordCount\":124,\"commentCount\":0,\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/digitalpcr4\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2019\\\/07\\\/digitalpcr-title-3.jpeg\",\"keywords\":[\"\u30c7\u30b8\u30bf\u30ebPCR\"],\"articleSection\":[\"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023\"],\"inLanguage\":\"ja\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/digitalpcr4\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/digitalpcr4\\\/\",\"url\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/digitalpcr4\\\/\",\"name\":\"\u30c7\u30b8\u30bf\u30ebPCR\u306b\u3088\u308b\u6b21\u4e16\u4ee3\u30b7\u30fc\u30b1\u30f3\u30b5(NGS)\u306e\u30e9\u30a4\u30d6\u30e9\u30ea\u306e\u9ad8\u7cbe\u5ea6\u306a\u5b9a\u91cf - Learning at the Bench\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/digitalpcr4\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/digitalpcr4\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2019\\\/07\\\/digitalpcr-title-3.jpeg\",\"datePublished\":\"2016-04-13T15:00:00+00:00\",\"dateModified\":\"2025-07-01T07:56:11+00:00\",\"author\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#\\\/schema\\\/person\\\/00a095a01d54afcdf9457465feb04f7d\"},\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/digitalpcr4\\\/#breadcrumb\"},\"inLanguage\":\"ja\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/digitalpcr4\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"ja\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/digitalpcr4\\\/#primaryimage\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2019\\\/07\\\/digitalpcr-title-3.jpeg\",\"contentUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2019\\\/07\\\/digitalpcr-title-3.jpeg\",\"width\":600,\"height\":315,\"caption\":\"digitalpcr-title\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/digitalpcr4\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"\u30c7\u30b8\u30bf\u30ebPCR\u306b\u3088\u308b\u6b21\u4e16\u4ee3\u30b7\u30fc\u30b1\u30f3\u30b5(NGS)\u306e\u30e9\u30a4\u30d6\u30e9\u30ea\u306e\u9ad8\u7cbe\u5ea6\u306a\u5b9a\u91cf\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#website\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/\",\"name\":\"Learning at the Bench\",\"description\":\"\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"ja\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#\\\/schema\\\/person\\\/00a095a01d54afcdf9457465feb04f7d\",\"name\":\"LATB Staff\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"ja\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/8803277856c8b753feb4217dff0f9953327452df1a615c3c88b2f9864efb2ddd?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/8803277856c8b753feb4217dff0f9953327452df1a615c3c88b2f9864efb2ddd?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/8803277856c8b753feb4217dff0f9953327452df1a615c3c88b2f9864efb2ddd?s=96&d=mm&r=g\",\"caption\":\"LATB Staff\"},\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/author\\\/latbstaff\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"\u30c7\u30b8\u30bf\u30ebPCR\u306b\u3088\u308b\u6b21\u4e16\u4ee3\u30b7\u30fc\u30b1\u30f3\u30b5(NGS)\u306e\u30e9\u30a4\u30d6\u30e9\u30ea\u306e\u9ad8\u7cbe\u5ea6\u306a\u5b9a\u91cf - Learning at the Bench","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/digitalpcr4\/","og_locale":"ja_JP","og_type":"article","og_title":"\u30c7\u30b8\u30bf\u30ebPCR\u306b\u3088\u308b\u6b21\u4e16\u4ee3\u30b7\u30fc\u30b1\u30f3\u30b5(NGS)\u306e\u30e9\u30a4\u30d6\u30e9\u30ea\u306e\u9ad8\u7cbe\u5ea6\u306a\u5b9a\u91cf","og_description":"\u30c7\u30b8\u30bf\u30ebPCR (dPCR) \u3092\u7d39\u4ecb\u3057\u3066\u3044\u308b6\u90e8\u69cb\u6210\u30b7\u30ea\u30fc\u30ba\u306e\u30d1\u30fc\u30c84\u3068\u3057\u3066\u3001\u4eca\u56de\u306f\u3001\u30c7\u30b8\u30bf\u30ebPCR\u306b\u3088\u308b\u6b21\u4e16\u4ee3\u30b7\u30fc\u30b1\u30f3\u30b5(NGS)\u306e\u30e9\u30a4\u30d6\u30e9\u30ea\u306e\u9ad8\u7cbe\u5ea6\u306a\u5b9a\u91cf\u306b\u3064\u3044\u3066\u3054\u7d39\u4ecb\u3057\u307e\u3059\u3002\u30c7\u30b8\u30bf\u30ebPCR\u306f\u3001NGS\u30e9\u30a4\u30d6\u30e9\u30ea\u5b9a\u91cf\u3092\u30b7\u30f3\u30d7\u30eb\u304b\u3064\u6b63\u78ba\u306b\u884c\u3044\u3001\u30de\u30a4\u30af\u30ed\u30c1\u30c3\u30d7\u578b\u96fb\u6c17\u6cf3\u52d5\u3084\u5206\u5149\u5149\u5ea6\u8a08\u3068\u3044\u3063\u305f\u4ed6\u306e\u624b\u6cd5\u3092\u7528\u3044\u305f\u3068\u304d\u306b\u8d77\u3053\u308a\u304c\u3061\u306a\u3001\u30e9\u30a4\u30d6\u30e9\u30ea\u6fc3\u5ea6\u3092\u8aa4\u3063\u3066\u8a55\u4fa1\u3059\u308b\u53ef\u80fd\u6027\u3092\u8efd\u6e1b\u3057\u307e\u3059\u3002","og_url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/digitalpcr4\/","og_site_name":"Learning at the Bench","article_publisher":"https:\/\/www.facebook.com\/ThermoFisherJapan","article_published_time":"2016-04-13T15:00:00+00:00","article_modified_time":"2025-07-01T07:56:11+00:00","og_image":[{"width":600,"height":315,"url":"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/digitalpcr-title-3.jpeg","type":"image\/jpeg"}],"author":"LATB Staff","twitter_card":"summary_large_image","twitter_creator":"@ThermoFisherJP","twitter_site":"@ThermoFisherJP","twitter_misc":{"\u57f7\u7b46\u8005":"LATB Staff","\u63a8\u5b9a\u8aad\u307f\u53d6\u308a\u6642\u9593":"11\u5206"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/digitalpcr4\/#article","isPartOf":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/digitalpcr4\/"},"author":{"name":"LATB Staff","@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#\/schema\/person\/00a095a01d54afcdf9457465feb04f7d"},"headline":"\u30c7\u30b8\u30bf\u30ebPCR\u306b\u3088\u308b\u6b21\u4e16\u4ee3\u30b7\u30fc\u30b1\u30f3\u30b5(NGS)\u306e\u30e9\u30a4\u30d6\u30e9\u30ea\u306e\u9ad8\u7cbe\u5ea6\u306a\u5b9a\u91cf","datePublished":"2016-04-13T15:00:00+00:00","dateModified":"2025-07-01T07:56:11+00:00","mainEntityOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/digitalpcr4\/"},"wordCount":124,"commentCount":0,"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/digitalpcr4\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/digitalpcr-title-3.jpeg","keywords":["\u30c7\u30b8\u30bf\u30ebPCR"],"articleSection":["\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023"],"inLanguage":"ja","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/digitalpcr4\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/digitalpcr4\/","url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/digitalpcr4\/","name":"\u30c7\u30b8\u30bf\u30ebPCR\u306b\u3088\u308b\u6b21\u4e16\u4ee3\u30b7\u30fc\u30b1\u30f3\u30b5(NGS)\u306e\u30e9\u30a4\u30d6\u30e9\u30ea\u306e\u9ad8\u7cbe\u5ea6\u306a\u5b9a\u91cf - Learning at the Bench","isPartOf":{"@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/digitalpcr4\/#primaryimage"},"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/digitalpcr4\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/digitalpcr-title-3.jpeg","datePublished":"2016-04-13T15:00:00+00:00","dateModified":"2025-07-01T07:56:11+00:00","author":{"@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#\/schema\/person\/00a095a01d54afcdf9457465feb04f7d"},"breadcrumb":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/digitalpcr4\/#breadcrumb"},"inLanguage":"ja","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/digitalpcr4\/"]}]},{"@type":"ImageObject","inLanguage":"ja","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/digitalpcr4\/#primaryimage","url":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/digitalpcr-title-3.jpeg","contentUrl":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/digitalpcr-title-3.jpeg","width":600,"height":315,"caption":"digitalpcr-title"},{"@type":"BreadcrumbList","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/digitalpcr4\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/"},{"@type":"ListItem","position":2,"name":"\u30c7\u30b8\u30bf\u30ebPCR\u306b\u3088\u308b\u6b21\u4e16\u4ee3\u30b7\u30fc\u30b1\u30f3\u30b5(NGS)\u306e\u30e9\u30a4\u30d6\u30e9\u30ea\u306e\u9ad8\u7cbe\u5ea6\u306a\u5b9a\u91cf"}]},{"@type":"WebSite","@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#website","url":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/","name":"Learning at the Bench","description":"","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"ja"},{"@type":"Person","@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#\/schema\/person\/00a095a01d54afcdf9457465feb04f7d","name":"LATB Staff","image":{"@type":"ImageObject","inLanguage":"ja","@id":"https:\/\/secure.gravatar.com\/avatar\/8803277856c8b753feb4217dff0f9953327452df1a615c3c88b2f9864efb2ddd?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/8803277856c8b753feb4217dff0f9953327452df1a615c3c88b2f9864efb2ddd?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/8803277856c8b753feb4217dff0f9953327452df1a615c3c88b2f9864efb2ddd?s=96&d=mm&r=g","caption":"LATB Staff"},"url":"https:\/\/admin.acceleratingscience.com\/author\/latbstaff\/"}]}},"taxonomy_info":{"category":[{"value":156,"label":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023"}],"post_tag":[{"value":44,"label":"\u30c7\u30b8\u30bf\u30ebPCR"}]},"featured_image_src_large":["https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/digitalpcr-title-3.jpeg",600,315,false],"author_info":{"display_name":"LATB Staff","author_link":"https:\/\/admin.acceleratingscience.com\/author\/latbstaff\/"},"comment_info":0,"category_info":[{"term_id":156,"name":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","slug":"mol-bio","term_group":0,"term_taxonomy_id":156,"taxonomy":"category","description":"","parent":0,"count":537,"filter":"raw","meta":[],"cat_ID":156,"category_count":537,"category_description":"","cat_name":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","category_nicename":"mol-bio","category_parent":0}],"tag_info":[{"term_id":44,"name":"\u30c7\u30b8\u30bf\u30ebPCR","slug":"digital-pcr","term_group":0,"term_taxonomy_id":44,"taxonomy":"post_tag","description":"","parent":0,"count":27,"filter":"raw","meta":[]}],"jetpack-related-posts":[{"id":24953,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/ngs-gene-expression-csd-ts-ion-26011\/","url_meta":{"origin":358,"position":0},"title":"\u30e9\u30a4\u30d6\u30e9\u30ea\u30fc\u8abf\u88fd\u306e\u81ea\u52d5\u5316\u3067NGS\u306e\u53ef\u80fd\u6027\u3092\u5e83\u3052\u308b\u2015Ion Chef\u30b7\u30b9\u30c6\u30e0\u304c\u5909\u3048\u308b\u7814\u7a76\u5ba4\u306e\u30ef\u30fc\u30af\u30d5\u30ed\u30fc","author":"LatB Staff","date":"2026\u5e744\u670810\u65e5","format":false,"excerpt":"\u524d\u51e6\u7406\u306e\u81ea\u52d5\u5316\u304c\u3001NGS\u306e\u65b0\u3057\u3044\u6a19\u6e96\u3092\u3064\u304f\u308b\u6b21\u4e16\u4ee3\u30b7\u30fc\u30b1\u30f3\u30b7\u30f3\u30b0\uff08NGS\uff09\u304c\u65e5\u5e38\u7684\u306a\u7814\u7a76\u30c4\u30fc\u30eb\u3068\u306a\u3063\u2026","rel":"","context":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","block_context":{"text":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/mol-bio\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/02\/ngs-gene-expression-csd-ts-ion-26011_eyecatch.jpeg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/02\/ngs-gene-expression-csd-ts-ion-26011_eyecatch.jpeg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/02\/ngs-gene-expression-csd-ts-ion-26011_eyecatch.jpeg?resize=525%2C300&ssl=1 1.5x"},"classes":[]},{"id":24187,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/ngs-gene-expression-csd-ts-ion-25073\/","url_meta":{"origin":358,"position":1},"title":"\u3010\u3084\u3063\u3066\u307f\u305f\u3011\u5fae\u91cf\u30fb\u5206\u89e3RNA\u306b\u3088\u308b\u767a\u73fe\u89e3\u6790\u306e\u6700\u9069\u89e3\u306f\uff1fRNA-Seq\u3068Ion AmpliSeq Transcriptome\u3092\u6bd4\u3079\u3066\u307f\u305f","author":"LatB Staff","date":"2025\u5e7411\u670828\u65e5","format":false,"excerpt":"\u6b21\u4e16\u4ee3\u30b7\u30fc\u30b1\u30f3\u30b5\u3067\u306e\u767a\u73fe\u89e3\u6790\u306b\u53d6\u308a\u7d44\u3080\u969b\u3001RNA\u30b5\u30f3\u30d7\u30eb\u304c\u300c\u5c11\u306a\u3059\u304e\u308b\u300d\u300c\u5206\u89e3\u3057\u3066\u3044\u308b\u300d\u3068\u3044\u3046\u72b6\u6cc1\u306f\u2026","rel":"","context":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","block_context":{"text":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/mol-bio\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/11\/ngs-gene-expression-csd-ts-ion-25073_eyecatch-scaled.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/11\/ngs-gene-expression-csd-ts-ion-25073_eyecatch-scaled.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/11\/ngs-gene-expression-csd-ts-ion-25073_eyecatch-scaled.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/11\/ngs-gene-expression-csd-ts-ion-25073_eyecatch-scaled.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/11\/ngs-gene-expression-csd-ts-ion-25073_eyecatch-scaled.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/11\/ngs-gene-expression-csd-ts-ion-25073_eyecatch-scaled.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":24545,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/digital-pcr-gene-expression-gsd-ts-sd-25082\/","url_meta":{"origin":358,"position":2},"title":"\u3010Absolute Q\u30c7\u30b8\u30bf\u30ebPCR\u30b7\u30b9\u30c6\u30e0\u306e\u6d3b\u7528\u4f8b\u3011\u30df\u30c8\u30b3\u30f3\u30c9\u30ea\u30a2DNA\u306e\u5b9a\u91cf","author":"LatB Staff","date":"2026\u5e741\u670816\u65e5","format":false,"excerpt":"Applied Biosystems\u2122 QuantStudio\u2122 Absolute Q\u2122 \u30c7\u30b8\u30bf\u30ebP\u2026","rel":"","context":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","block_context":{"text":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/mol-bio\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/12\/digital-pcr-gene-expression-gsd-ts-sd-25082_eyecatch.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/12\/digital-pcr-gene-expression-gsd-ts-sd-25082_eyecatch.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/12\/digital-pcr-gene-expression-gsd-ts-sd-25082_eyecatch.jpg?resize=525%2C300&ssl=1 1.5x"},"classes":[]},{"id":23370,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/pcr-dna-gsd-ts-tr-25061\/","url_meta":{"origin":358,"position":3},"title":"\u3010\u3084\u3063\u3066\u307f\u305f\u3011PCR\u5f8c\u306e\u4fdd\u5b58\u6e29\u5ea6\u306f4\u2103\u4e00\u629e\u3067\u3059\u304b\uff1f\u4ed6\u306e\u6e29\u5ea6\u3082\u8a66\u3057\u3066\u307f\u305f","author":"LatB Staff","date":"2025\u5e7410\u670816\u65e5","format":false,"excerpt":"PCR\uff08\u30dd\u30ea\u30e1\u30e9\u30fc\u30bc\u9023\u9396\u53cd\u5fdc\uff09\u306f\u3001\u5206\u5b50\u751f\u7269\u5b66\u306e\u5b9f\u9a13\u306e\u6839\u5e79\u3092\u306a\u3059\u975e\u5e38\u306b\u91cd\u8981\u306a\u6280\u8853\u3067\u3059\u3002PCR\u3092\u884c\u3063\u305f\u5f8c\u2026","rel":"","context":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","block_context":{"text":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/mol-bio\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/10\/pcr-dna-gsd-ts-tr-25061_eyecatch.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/10\/pcr-dna-gsd-ts-tr-25061_eyecatch.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/10\/pcr-dna-gsd-ts-tr-25061_eyecatch.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/10\/pcr-dna-gsd-ts-tr-25061_eyecatch.jpg?resize=700%2C400&ssl=1 2x"},"classes":[]},{"id":23239,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/ngs-gene-expression-csd-ts-bfx-25060\/","url_meta":{"origin":358,"position":4},"title":"\u98df\u54c1\u958b\u767a\u306b\u304a\u3051\u308b\u83cc\u53e2\u89e3\u6790\u3068\u907a\u4f1d\u5b50\u767a\u73fe\u89e3\u6790\u306e\u6d3b\u7528","author":"LatB Staff","date":"2025\u5e7410\u67088\u65e5","format":false,"excerpt":"\u907a\u4f1d\u5b50\u95a2\u9023\u306e\u89e3\u6790\u6280\u8853\u304c\u7814\u7a76\u306e\u307f\u306a\u3089\u305a\u7523\u696d\u5206\u91ce\u3067\u6d3b\u7528\u3055\u308c\u308b\u3088\u3046\u306b\u306a\u308a\u3001\u5e74\u6708\u304c\u7d4c\u904e\u3059\u308b\u306b\u3064\u308c\u3066\u5fdc\u7528\u7bc4\u56f2\u3082\u2026","rel":"","context":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","block_context":{"text":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/mol-bio\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/09\/ngs-gene-expression-gsd-ts-tr-25060_eyecatch.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/09\/ngs-gene-expression-gsd-ts-tr-25060_eyecatch.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/09\/ngs-gene-expression-gsd-ts-tr-25060_eyecatch.jpg?resize=525%2C300&ssl=1 1.5x"},"classes":[]},{"id":25325,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/exosome-gene-expression-ts-r-25019\/","url_meta":{"origin":358,"position":5},"title":"\u3010\u7b2c5\u56de\u3011 &#8220;RNA cargo&#8221;\u306e\u7cbe\u88fd\u3068\u5b9a\u91cf\u89e3\u6790\u300d\uff5emRNA\u306e\u5b9a\u91cf\u89e3\u6790\uff5e","author":"LatB Staff","date":"2026\u5e746\u670811\u65e5","format":false,"excerpt":"\u4eca\u56de\u306f\u3001\u30a8\u30af\u30bd\u30bd\u30fc\u30e0\uff08\u30a8\u30ad\u30bd\u30bd\u30fc\u30e0\uff09\u4e2d\u306emRNA\u306e\u5b9a\u91cf\u89e3\u6790\u306b\u3064\u3044\u3066\u8aac\u660e\u3057\u307e\u3059\u3002\u7b2c3\u56de\u3067\u30a8\u30af\u30bd\u30bd\u30fc\u30e0\u304b\u2026","rel":"","context":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","block_context":{"text":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/mol-bio\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25018_eyecatch-1.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25018_eyecatch-1.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25018_eyecatch-1.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25018_eyecatch-1.jpg?resize=700%2C400&ssl=1 2x"},"classes":[]}],"jetpack_sharing_enabled":true,"amp_enabled":true,"jetpack_featured_media_url":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/digitalpcr-title-3.jpeg","_links":{"self":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/posts\/358","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/users\/988"}],"replies":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/comments?post=358"}],"version-history":[{"count":0,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/posts\/358\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/media\/2574"}],"wp:attachment":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/media?parent=358"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/categories?post=358"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/tags?post=358"},{"taxonomy":"division","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/division?post=358"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}