{"id":381,"date":"2016-05-12T00:00:00","date_gmt":"2016-05-11T15:00:00","guid":{"rendered":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/digitalpcr6\/"},"modified":"2025-07-01T17:08:10","modified_gmt":"2025-07-01T08:08:10","slug":"digitalpcr6","status":"publish","type":"post","link":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/digitalpcr6\/","title":{"rendered":"\u7d76\u5bfe\u5b9a\u91cf\u3084\u30ec\u30a2\u306a\u914d\u5217\u306e\u691c\u51fa\u304c\u53ef\u80fd\u306a\u30c7\u30b8\u30bf\u30ebPCR\u306e\u5229\u70b9\u3092\u6d3b\u7528\u3057\u305f\u69d8\u3005\u306a\u30a2\u30d7\u30ea\u30b1\u30fc\u30b7\u30e7\u30f3\u306e\u4e8b\u4f8b\u307e\u3068\u3081"},"content":{"rendered":"<p>\u30c7\u30b8\u30bf\u30ebPCR\u306f\u9ad8\u611f\u5ea6\u30fb\u9ad8\u7cbe\u5ea6\u306a\u7d76\u5bfe\u5b9a\u91cf\u3092\u884c\u3046\u3053\u3068\u304c\u3067\u304d\u308b\u306e\u3067\u3001\u69d8\u3005\u306a\u30a2\u30d7\u30ea\u30b1\u30fc\u30b7\u30e7\u30f3\u306b\u304a\u3051\u308b\u30a2\u30c3\u30bb\u30a4\u306e\u30d1\u30d5\u30a9\u30fc\u30de\u30f3\u30b9\u306e\u6700\u9069\u5316\u3092\u6709\u52b9\u306b\u304a\u3053\u306a\u3046\u3053\u3068\u304c\u3067\u304d\u307e\u3059\u3002\u305f\u3068\u3048\u3070\u3001<strong><a href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/life-science\/pcr\/digital-pcr.html?CID=gsd_pcr_sbu_r04_jp_cp0000_pjt0000_gsd00000_0so_blg_op_awa_oc_s00_qpcr41_Social_LAB\" target=\"_blank\" rel=\"noopener noreferrer\">\u5fae\u91cf\u306e\u75c5\u539f\u83cc\u306e\u691c\u51fa\u5b9a\u91cf<\/a>\u3067\u306f\u75c5\u539f\u83cc\u306e\u30b3\u30d4\u30fc\u6570\u3092\u76f4\u63a5\u5f97\u308b\u3053\u3068\u304c\u3067\u304d\u307e\u3059<\/strong>\u3002<strong><a href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/life-science\/pcr\/digital-pcr\/quantstudio-3d-applications\/sensitive-gmo-detection.html?CID=gsd_pcr_sbu_r04_jp_cp0000_pjt0000_gsd00000_0so_blg_op_awa_oc_s00_qpcr41_Social_LAB\" target=\"_blank\" rel=\"noopener noreferrer\">\u907a\u4f1d\u5b50\u7d44\u307f\u63db\u3048\u4f5c\u7269(GMO)\u306e\u691c\u51fa<\/a>\u3067\u306f\u3001\u308f\u305a\u304b1\u500b\u306e\u7a2e\u306e\u6df7\u5165\u3082\u691c\u51fa\u53ef\u80fd\u306a\u611f\u5ea6\u304c\u5f97\u3089\u308c\u307e\u3059<\/strong>\u3002\u307e\u305f\u3001<strong>\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u5b9f\u9a13\u306b\u4f7f\u7528\u3059\u308b<a href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/life-science\/pcr\/digital-pcr\/quantstudio-3d-applications\/absolute-quantification-references-standards.html?CID=gsd_pcr_sbu_r04_jp_cp0000_pjt0000_gsd00000_0so_blg_op_awa_oc_s00_qpcr41_Social_LAB\" target=\"_blank\" rel=\"noopener noreferrer\">\u6a19\u6e96\u30b5\u30f3\u30d7\u30eb\u306e\u7d76\u5bfe\u5b9a\u91cf<\/a>\u3092\u884c\u3046\u3053\u3068\u3082\u3067\u304d\u307e\u3059<\/strong>\u3002<\/p>\n<p><a href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/life-science\/pcr\/digital-pcr.html?CID=gsd_pcr_sbu_r04_jp_cp0000_pjt0000_gsd00000_0so_blg_op_awa_oc_s00_qpcr41_Social_LAB\" target=\"_blank\" rel=\"noopener noreferrer\">QuantStudio 3D \u30c7\u30b8\u30bf\u30ebPCR\u30b7\u30b9\u30c6\u30e0<\/a>\u3068\u76f4\u611f\u7684\u306a\u30e6\u30fc\u30b6\u30fc\u30a4\u30f3\u30bf\u30fc\u30d5\u30a7\u30fc\u30b9\u3092\u5099\u3048\u305f\u30c7\u30fc\u30bf\u89e3\u6790\u30c4\u30fc\u30eb<a href=\"http:\/\/www.thermofisher.com\/jp\/ja\/home\/life-science\/pcr\/digital-pcr\/quantstudio-3d-digital-pcr-system\/quantstudio-3d-software.html?CID=gsd_pcr_sbu_r04_jp_cp0000_pjt0000_gsd00000_0so_blg_op_awa_oc_s00_qpcr41_Social_LAB\" target=\"_blank\" rel=\"noopener noreferrer\">QuantStudio 3D AnalysisSuite Cloud \u30bd\u30d5\u30c8\u30a6\u30a7\u30a2<\/a>\u306f\u3001\u75c5\u539f\u4f53\u3084\u30a6\u30a3\u30eb\u30b9\u30b3\u30d4\u30fc\u6570\u306e\u7d76\u5bfe\u5b9a\u91cf\u306a\u3069\u3001\u3055\u307e\u3056\u307e\u306a\u30a2\u30d7\u30ea\u30b1\u30fc\u30b7\u30e7\u30f3\u3092\u30b5\u30dd\u30fc\u30c8\u3057\u307e\u3059\u3002<\/p>\n<p>QuantStudio 3D \u30c7\u30b8\u30bf\u30ebPCR\u30b7\u30b9\u30c6\u30e0\u306f\u3001TaqMan \u304a\u3088\u3073 SYBR \u30b1\u30df\u30b9\u30c8\u30ea\u306e\u4e21\u65b9\u3092\u691c\u51fa\u3067\u304d\u307e\u3059\u3002TaqMan\u30b1\u30df\u30b9\u30c8\u30ea\u306f\u5b9a\u91cfPCR\u306b\u304a\u3051\u308b\u507d\u967d\u6027\u306e\u30ea\u30b9\u30af\u3092\u6700\u5c0f\u9650\u306b\u6291\u3048\u308b\u3053\u3068\u304c\u3067\u304d\u307e\u3059\u3002QuantStudio 3D \u30c7\u30b8\u30bf\u30ebPCR\u3067\u306f\u3001800\u4e07\u7a2e\u985e\u3092\u8d85\u3048\u308b\u30d7\u30ec\u30c7\u30b6\u30a4\u30f3\u306eTaqMan\u30a2\u30c3\u30bb\u30a4\u304c\u3054\u5229\u7528\u306b\u306a\u308c\u307e\u3059\u3002<\/p>\n<h2>\u308f\u305a\u304b\u306a\u6642\u9593\u3067\u7d76\u5bfe\u5b9a\u91cf\u3092\u53ef\u80fd\u306b\u3059\u308bQuantStudio 3D \u30c7\u30b8\u30bf\u30ebPCR\u30b7\u30b9\u30c6\u30e0<\/h2>\n<p><a href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/life-science\/pcr\/digital-pcr.html?CID=gsd_pcr_sbu_r04_jp_cp0000_pjt0000_gsd00000_0so_blg_op_awa_oc_s00_qpcr41_Social_LAB\" target=\"_blank\" rel=\"noopener noreferrer\">QuantStudio 3D \u30c7\u30b8\u30bf\u30ebPCR\u30b7\u30b9\u30c6\u30e0<\/a>\u306f\u3001\u30b7\u30f3\u30d7\u30eb\u304b\u3064\u304a\u624b\u9803\u306a\u30c7\u30b8\u30bf\u30ebPCR\u30d7\u30e9\u30c3\u30c8\u30d5\u30a9\u30fc\u30e0\u3067\u3059\u3002<strong>\u5358\u4e00\u5206\u5b50\u3092100\u4e07\u500d\u4ee5\u4e0a\u306b\u5897\u5e45\u3067\u304d\u308b\u306e\u3067\u3001\u9ad8\u3044\u7cbe\u5ea6\u3068\u611f\u5ea6\u3067\u6838\u9178\u306e\u691c\u51fa\u3084\u30ec\u30a2\u5909\u7570\u306e\u7d76\u5bfe\u5b9a\u91cf\u304c\u53ef\u80fd<\/strong>\u3067\u3059\u3002<\/p>\n<p>QuantStudio 3D \u30c7\u30b8\u30bf\u30ebPCR\u30b7\u30b9\u30c6\u30e0\u306f\u3001\u30ca\u30ce\u6d41\u4f53\u5de5\u5b66\u306b\u57fa\u3065\u304f\u9ad8\u5bc6\u5ea6\u306e\u30c1\u30c3\u30d7\u30c6\u30af\u30ce\u30ed\u30b8\u30fc\u3092\u63a1\u7528\u3057\u3001\u72ec\u7acb\u3057\u305f20,000\u500b\u306e\u53cd\u5fdc\u30a6\u30a7\u30eb\u306b\u30b5\u30f3\u30d7\u30eb\u3092\u5206\u914d\u3057\u307e\u3059\u3002<a href=\"https:\/\/www.thermofisher.com\/order\/catalog\/product\/A26316?CID=gsd_pcr_sbu_r04_jp_cp0000_pjt0000_gsd00000_0so_blg_op_awa_oc_s00_qpcr41_Social_LAB\" target=\"_blank\" rel=\"noopener noreferrer\">QuantStudio 3D \u30c7\u30b8\u30bf\u30ebPCR \u30c1\u30c3\u30d7<\/a>\u4e0a\u306b\u306f\u56fa\u4f53\u30b7\u30ea\u30b3\u30f3\u57fa\u677f\u306b\u523b\u307f\u8fbc\u307e\u308c\u305f\u5747\u4e00\u30b5\u30a4\u30ba\u306e\u30a6\u30a7\u30eb\u304c\u3042\u308b\u306e\u3067\u3001\u76f4\u63a5\u7684\u304b\u3064\u5b89\u5b9a\u3057\u305f\u30b5\u30f3\u30d7\u30eb\u5206\u914d\u304c\u53ef\u80fd\u3067\u3059\u3002\u9ad8\u5ea6\u306b\u5236\u5fa1\u3055\u308c\u305f\u30b5\u30f3\u30d7\u30eb\u30ed\u30fc\u30c7\u30a3\u30f3\u30b0\u30b7\u30b9\u30c6\u30e0\u3068\u5fae\u7d30\u30a6\u30a7\u30eb\u306e\u30c1\u30c3\u30d7\u306e\u7d44\u307f\u5408\u308f\u305b\u306b\u3088\u308a\u3001\u9ad8\u7cbe\u5ea6\u306a\u7d76\u5bfe\u5b9a\u91cf\u3092\u5b9f\u73fe\u3057\u307e\u3059\u3002<\/p>\n<p>QuantStudio 3D \u30c7\u30b8\u30bf\u30ebPCR\u30b7\u30b9\u30c6\u30e0\u306f\u3001\u30b3\u30d4\u30fc\u6570\/\u03bcL\u306e\u30c7\u30fc\u30bf\u3092\u7b97\u51fa\u3059\u308b\u3068\u3068\u3082\u306b\u3001\u305d\u306e\u30c7\u30fc\u30bf\u306e\u54c1\u8cea\u3092\u8a55\u4fa1\u3057\u307e\u3059\u3002\u30c7\u30fc\u30bf\u54c1\u8cea\u304c\u60aa\u3044\u5834\u5408\u3084\u4e0d\u5408\u683c\u306e\u5834\u5408\u306f\u3001<a href=\"http:\/\/www.thermofisher.com\/jp\/ja\/home\/life-science\/pcr\/digital-pcr\/quantstudio-3d-digital-pcr-system\/quantstudio-3d-software.html?CID=gsd_pcr_sbu_r04_jp_cp0000_pjt0000_gsd00000_0so_blg_op_awa_oc_s00_qpcr41_Social_LAB\" target=\"_blank\" rel=\"noopener noreferrer\">QuantStudio 3D AnalysisSuite Cloud \u30bd\u30d5\u30c8\u30a6\u30a7\u30a2<\/a>\u30672\u6b21\u89e3\u6790\u3092\u884c\u3046\u969b\u306b\u3001\u78ba\u8a8d\u3092\u4fc3\u3059\u30d5\u30e9\u30b0\u304c\u4ed8\u52a0\u3055\u308c\u307e\u3059\u3002<\/p>\n<h2>\u5fae\u91cf\u306e\u75c5\u539f\u83cc\u306e\u691c\u51fa\u30fb\u5b9a\u91cf<\/h2>\n<p>\u6c5a\u67d3\u98df\u54c1\u3084\u6c5a\u67d3\u6c34\u306b\u542b\u307e\u308c\u308b\u7d30\u83cc\u3084\u30a6\u30a3\u30eb\u30b9\u6027\u75c5\u539f\u83cc\u306e\u30d2\u30c8\u3078\u306e\u5f71\u97ff\u3092\u6e1b\u3089\u3059\u305f\u3081\u306b\u306f\u3001<a href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/life-science\/pcr\/digital-pcr.html?CID=gsd_pcr_sbu_r04_jp_cp0000_pjt0000_gsd00000_0so_blg_op_awa_oc_s00_qpcr41_Social_LAB\" target=\"_blank\" rel=\"noopener noreferrer\">\u5fae\u91cf\u306e\u75c5\u539f\u83cc\u306e\u691c\u51fa\u30fb\u5b9a\u91cf<\/a>\u3092\u3067\u304d\u308b\u3060\u3051\u65e9\u3044\u6bb5\u968e\u3067\u884c\u3046\u5fc5\u8981\u304c\u3042\u308a\u307e\u3059\u3002<\/p>\n<p><strong>\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u306f\u3001\u75c5\u539f\u83cc\u306e\u691c\u51fa\u306b\u304a\u3044\u3066\u6709\u7528\u306a\u30c4\u30fc\u30eb\u3067\u3059\u304c\u3001\u98df\u54c1\u3084\u6c34\u8cea\u691c\u67fb\u3067\u7528\u3044\u3089\u308c\u308b\u30b5\u30f3\u30d7\u30eb\u306b\u306fPCR\u963b\u5bb3\u7269\u8cea\u304c\u542b\u307e\u308c\u3066\u3044\u308b\u3053\u3068\u304c\u3042\u308a\u3001\u305d\u306e\u5f71\u97ff\u3092\u53d7\u3051\u308b\u53ef\u80fd\u6027\u304c\u3042\u308a\u307e\u3059<\/strong>\u3002\u4e00\u65b9\u3001<strong>\u30c7\u30b8\u30bf\u30ebPCR\u306f\u3001\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u3068\u6bd4\u8f03\u3057\u3066\u3001\u963b\u5bb3\u7269\u8cea\u306e\u5f71\u97ff\u3092\u53d7\u3051\u306b\u304f\u3044\u6280\u8853<\/strong>\u3067\u3059\u3002\u30c7\u30b8\u30bf\u30ebPCR\u306f\u3001\u5fae\u7d30\u306a\u30a6\u30a7\u30eb\u306b\u30b5\u30f3\u30d7\u30eb\u3092\u5206\u914d\u3059\u308b\u306e\u3068\u540c\u6642\u306b\u963b\u5bb3\u7269\u8cea\u3092\u5e0c\u91c8\u3057\u307e\u3059\u3002\u3055\u3089\u306b\u5897\u5e45\u91cf\u3067\u306f\u306a\u304f\u3001\u5206\u914d\u3055\u308c\u305f1\u30b3\u30d4\u30fc\u306e\u30b5\u30f3\u30d7\u30eb\u306ePCR\u5897\u5e45\u306e\u6709\u7121\u304b\u3089\u7d76\u5bfe\u5b9a\u91cf\u3092\u884c\u3044\u307e\u3059\u3002\u5f93\u3063\u3066\u3001PCR\u52b9\u7387\u304c\u640d\u306a\u308f\u308c\u308b\u3088\u3046\u306a\u5834\u5408\u306b\u304a\u3044\u3066\u3082\u3001\u305d\u306e\u5f71\u97ff\u3092\u53d7\u3051\u306b\u304f\u3044\u30c7\u30b8\u30bf\u30ebPCR\u306f\u9ad8\u7cbe\u5ea6\u306a\u5b9a\u91cf\u304c\u53ef\u80fd\u3067\u3059\u3002\u307e\u305f\u3001<strong>\u30c7\u30b8\u30bf\u30ebPCR\u306f\u30ea\u30d5\u30a1\u30ec\u30f3\u30b9\u30b5\u30f3\u30d7\u30eb\u3084\u6a19\u6e96\u66f2\u7dda\u304c\u4e0d\u8981\u306a\u306e\u3067\u3001\u30ea\u30d5\u30a1\u30ec\u30f3\u30b9\u30b5\u30f3\u30d7\u30eb\u3092\u5165\u624b\u3057\u306b\u304f\u3044\u75c5\u539f\u83cc\u306e\u7d76\u5bfe\u5b9a\u91cf\u306b\u304a\u3044\u3066\u3082\u6709\u7528<\/strong>\u3067\u3059\u3002<\/p>\n<div id=\"attachment_1158\" style=\"width: 615px\" class=\"wp-caption aligncenter\"><a href=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/digitalpcr6-fig1.jpg\" rel=\"attachment wp-att-1158\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-1158\" class=\"size-full wp-image-1158\" src=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/digitalpcr6-fig1.jpg\" alt=\"digitalpcr6-fig1\" width=\"605\" height=\"549\" \/><\/a><p id=\"caption-attachment-1158\" class=\"wp-caption-text\">X\u8ef8\uff1a\u30d5\u30df\u30f3\u9178\u6fc3\u5ea6, Y\u8ef8\uff1a\u5b9a\u91cf\u3057\u305f\u6fc3\u5ea6<\/p><\/div>\n<p>\u74b0\u5883\u4e2d\u306b\u3088\u304f\u898b\u3089\u308c\u308bPCR\u963b\u5bb3\u7269\u8cea\u3067\u3042\u308b\u30d5\u30df\u30f3\u9178\u3092\u6dfb\u52a0\u3057\u3066\u3001\u3042\u308b\u75c5\u539f\u83cc\u306e\u6fc3\u5ea6\u6e2c\u5b9a\u3092\u884c\u3044\u307e\u3057\u305f\u3002\u30d5\u30df\u30f3\u9178\u306e\u6fc3\u5ea6\u304c\u9ad8\u304f\u306a\u308b\u3068\u3001\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\uff08\u30b0\u30ec\u30fc\u306e\u30e9\u30a4\u30f3\uff09\u306e\u6e2c\u5b9a\u5024\u306f\u3001\u5927\u304d\u304f\u4e0b\u304c\u308a\u307e\u3057\u305f\u3002\u307e\u305f\u3001\u30c7\u30b8\u30bf\u30ebPCR\u306e\u6e2c\u5b9a\u5024\uff08\u9752\u3044\u30e9\u30a4\u30f3\uff09\u306e\u30a8\u30e9\u30fc\u30d0\u30fc\u306f\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u3068\u6bd4\u8f03\u3057\u3066\u975e\u5e38\u306b\u5c0f\u3055\u3044\u3053\u3068\u304c\u308f\u304b\u308a\u307e\u3059\u3002<\/p>\n<h2>GMO\u3092\u9ad8\u611f\u5ea6\u306b\u691c\u51fa<\/h2>\n<p>\u690d\u7269\u306e\u8868\u73fe\u578b\u306e\u907a\u4f1d\u7684\u306a\u8907\u96d1\u3055\u3092\u7406\u89e3\u3059\u308b\u306e\u306f\u81f3\u96e3\u306e\u696d\u3067\u3059\u3002GMO\u4f5c\u7269\u306e\u4e16\u754c\u7684\u306a\u666e\u53ca\u3068\u3068\u3082\u306b\u3001\u98df\u54c1\u306e\u5b89\u5168\u6027\u306e\u305f\u3081\u306b\u6b63\u78ba\u306a\u8868\u793a\u7fa9\u52d9\u304c\u8ab2\u3055\u308c\u3001<a href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/life-science\/pcr\/digital-pcr\/quantstudio-3d-applications\/sensitive-gmo-detection.html?CID=gsd_pcr_sbu_r04_jp_cp0000_pjt0000_gsd00000_0so_blg_op_awa_oc_s00_qpcr41_Social_LAB\" target=\"_blank\" rel=\"noopener noreferrer\">\u9ad8\u7cbe\u5ea6\u306aGMO\u691c\u51fa<\/a>\u306e\u5fc5\u8981\u6027\u304c\u9ad8\u307e\u3063\u3066\u3044\u307e\u3059\u3002<\/p>\n<p>\u5f93\u6765\u3001<strong>\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR \u306f\u690d\u7269\u306e\u907a\u4f1d\u5b50\u767a\u73fe\u5b9a\u91cf\u306b\u5e83\u304f\u4f7f\u7528\u3055\u308c\u3066\u304d\u307e\u3057\u305f\u3002\u3057\u304b\u3057\u3001\u963b\u5bb3\u7269\u8cea\u306e\u5f71\u97ff\u3092\u53d7\u3051\u308b\u3068\u30bf\u30fc\u30b2\u30c3\u30c8\u907a\u4f1d\u5b50\u306e\u6fc3\u5ea6\u304c\u4f4e\u304f\u306a\u308b\u3053\u3068\u304c\u4e88\u60f3\u3055\u308c\u307e\u3059<\/strong>\u3002\u305d\u306e\u305f\u3081\u3001\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u306b\u3088\u308b\u690d\u7269\u306e\u5909\u7570\u306e\u5b9a\u91cf\u3084GMO\u306e\u691c\u51fa\u306f\u56f0\u96e3\u306a\u5834\u5408\u304c\u3042\u308a\u307e\u3057\u305f\u3002<\/p>\n<p>\u4e00\u65b9\u3001\u30c7\u30b8\u30bf\u30ebPCR\u306f\u3001GMO\u306e\u691c\u51fa\u3084\u690d\u7269\u306e\u5909\u7570\u907a\u4f1d\u5b50\u306e\u5b9a\u91cf\u306b\u7406\u60f3\u7684\u306a\u30b7\u30b9\u30c6\u30e0\u3067\u3059\u3002\u306a\u305c\u306a\u3089\u3001<strong>\u30c7\u30b8\u30bf\u30ebPCR\u306b\u3088\u308b\u30b5\u30f3\u30d7\u30eb\u4e2d\u306e\u7279\u5b9a\u306eSNPs\u3084\u30a2\u30ea\u30eb\u306e\u30bf\u30fc\u30b2\u30c3\u30c8\u306e\u7d76\u5bfe\u5b9a\u91cf\u306f\u91ce\u751f\u578b\u3068\u5909\u7570\u578b\u306e\u767a\u73fe\u306e\u9055\u3044\u3092\u89e3\u660e\u3057\u3001\u307e\u305f\u65b0\u898f\u306e\u30ec\u30a2\u306a\u5909\u7570\u306e\u691c\u51fa\u3082\u53ef\u80fd\u306b\u3059\u308b<\/strong>\u304b\u3089\u3067\u3059\u3002\u7e70\u308a\u8fd4\u3057\u306b\u306a\u308a\u307e\u3059\u304c\u3001\u30c7\u30b8\u30bf\u30ebPCR\u306f\u6a19\u6e96\u66f2\u7dda\u3092\u5fc5\u8981\u3068\u3057\u307e\u305b\u3093\u3002\u3055\u3089\u306b\u690d\u7269\u30b5\u30f3\u30d7\u30eb\u3067\u3088\u304f\u898b\u3089\u308c\u308b\u3055\u307e\u3056\u307e\u306aPCR\u963b\u5bb3\u7269\u8cea\u306b\u5bfe\u3057\u3066\u9ad8\u3044\u8010\u6027\u3092\u3082\u3063\u3066\u3044\u307e\u3059\u3002<\/p>\n<h2>\u9ad8\u7cbe\u5ea6\u306a\u907a\u4f1d\u5b50\u767a\u73fe\u89e3\u6790<\/h2>\n<p><strong>\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u306f\u3001\u4e00\u822c\u7684\u306b\u907a\u4f1d\u5b50\u767a\u73fe\u306e\u89e3\u6790\u306b\u4f7f\u308f\u308c\u3066\u3044\u307e\u3059\u304c\u3001\u901a\u5e38\u306f2\u500d\u4ee5\u4e0a\u306e\u767a\u73fe\u91cf\u306e\u9055\u3044\u304c\u306a\u3044\u3068\u8b58\u5225\u304c\u56f0\u96e3\u3067\u3059<\/strong>\u3002\u907a\u4f1d\u5b50\u767a\u73fe\u306e\u9055\u3044\u3092\u89e3\u6790\u3059\u308b\u306b\u306f\u3001\u4e00\u822c\u7684\u306b\u03b2\u30a2\u30af\u30c1\u30f3\u306a\u3069\u306e\u7d44\u7e54\u306b\u3088\u3063\u3066\u767a\u73fe\u91cf\u306b\u5dee\u306e\u306a\u3044\u3068\u8003\u3048\u3089\u308c\u308b\u30cf\u30a6\u30b9\u30ad\u30fc\u30d4\u30f3\u30b0\u907a\u4f1d\u5b50\u3092\u5185\u90e8\u6a19\u6e96\u3068\u3057\u3066\u5229\u7528\u3057\u307e\u3059\u3002<\/p>\n<p><strong>\u30c7\u30b8\u30bf\u30ebPCR\u306f\u3001\u00b110%\u4ee5\u4e0b\u306e\u9ad8\u3044\u7cbe\u5ea6\u3067\u306e\u6e2c\u5b9a\u3092\u53ef\u80fd\u3068\u3057\u3001<a href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/life-science\/pcr\/digital-pcr.html?CID=gsd_pcr_sbu_r04_jp_cp0000_pjt0000_gsd00000_0so_blg_op_awa_oc_s00_qpcr41_Social_LAB\" target=\"_blank\" rel=\"noopener noreferrer\">\u907a\u4f1d\u5b50\u767a\u73fe\u306e\u5dee\u7570\u3092\u89e3\u6790<\/a>\u3059\u308b\u5834\u5408\u306b\u304a\u3044\u3066\u30822\u500d\u4ee5\u4e0b\u306e\u308f\u305a\u304b\u306a\u5dee\u7570\u306e\u8b58\u5225\u3092\u53ef\u80fd\u306b\u3057\u307e\u3059<\/strong>\u3002\u307e\u305f\u3001\u5185\u90e8\u6a19\u6e96\u3092\u4f7f\u308f\u306a\u304f\u3066\u3082\u7d76\u5bfe\u5b9a\u91cf\u3092\u884c\u3046\u3053\u3068\u304c\u3067\u304d\u307e\u3059\u3002<\/p>\n<p>\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u3068\u540c\u69d8\u306b\u3001\u30c7\u30b8\u30bf\u30ebPCR\u3067\u3082RNA\u304b\u3089cDNA\u3078\u9006\u8ee2\u5199\u3092\u884c\u3044\u307e\u3059\u3002\u9ad8\u611f\u5ea6\u3067\u691c\u51fa\u3059\u308b\u305f\u3081\u306b\u306f\u3001\u9006\u8ee2\u5199\u52b9\u7387\u304c\u3068\u3066\u3082\u91cd\u8981\u306a\u30d5\u30a1\u30af\u30bf\u30fc\u3067\u3059\u3002\u5f0a\u793e\u3067\u306f\u30c7\u30b8\u30bf\u30ebPCR\u306e\u907a\u4f1d\u5b50\u767a\u73fe\u30ef\u30fc\u30af\u30d5\u30ed\u30fc\u3092\u5186\u6ed1\u306b\u9032\u3081\u3066\u3044\u305f\u3060\u304f\u305f\u3081\u306e\u52b9\u7387\u7684\u306a\u9006\u8ee2\u5199\u30ad\u30c3\u30c8\u3068\u3057\u3066\u3001<a href=\"http:\/\/www.thermofisher.com\/order\/catalog\/product\/4387406?CID=gsd_pcr_sbu_r04_jp_cp0000_pjt0000_gsd00000_0so_blg_op_awa_oc_s00_qpcr41_Social_LAB\" target=\"_blank\" rel=\"noopener noreferrer\">High-Capacity RNA-to-cDNA Kit<\/a>\u3092\u63d0\u4f9b\u3057\u3066\u3044\u307e\u3059\u3002<\/p>\n<div id=\"attachment_1159\" style=\"width: 690px\" class=\"wp-caption aligncenter\"><a href=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/digitalpcr6-fig2.jpg\" rel=\"attachment wp-att-1159\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-1159\" class=\"size-full wp-image-1159\" src=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/digitalpcr6-fig2.jpg\" alt=\"digitalpcr6-fig2\" width=\"680\" height=\"158\" \/><\/a><p id=\"caption-attachment-1159\" class=\"wp-caption-text\">\u30c7\u30b8\u30bf\u30ebPCR\uff08\u5de6\uff09\u3068\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0 qPCR\uff08\u53f3\uff09\u306e\u5b9a\u91cf\u7cbe\u5ea6\u306e\u6bd4\u8f03\u3002<\/p><\/div>\n<p>\u8aac\u660e: \u30b5\u30f3\u30d7\u30eb1\u304b\u30895\u306f\u3001\u5272\u5408\u306e\u7570\u306a\u308bmiRNA\u6df7\u5408\u30b5\u30f3\u30d7\u30eb\uff08hsa-miR-19b\u304a\u3088\u3073 hsa-miR-92\uff09\u3067\u3059\u3002\u30b5\u30f3\u30d7\u30eb 1: 100%\u3001\u30b5\u30f3\u30d7\u30eb 2: 95%\u3001\u30b5\u30f3\u30d7\u30eb 3: 90%\u3001\u30b5\u30f3\u30d7\u30eb 4: 75%\u3001\u30b5\u30f3\u30d7\u30eb 5: 50%\u3002\u9006\u8ee2\u5199\u3057\u305fcDNA\u3092\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u3001\u304a\u3088\u3073\u30c7\u30b8\u30bf\u30ebPCR \uff08QuantStudio 3D\u30b7\u30b9\u30c6\u30e0\uff09\u3067\u5b9a\u91cf\u3057\u307e\u3057\u305f\u3002\u5404\u56f3\u306e\u53f3\u5074\u306e\u591a\u91cd\u6bd4\u8f03\uff08Tukey-Kramer HSD test\uff09\u304c\u793a\u3059\u3068\u304a\u308a\u3001\u5186\u306e\u91cd\u306a\u308a\u304c\u306a\u3044\u30c7\u30b8\u30bf\u30ebPCR\uff08\u5de6\u56f3\uff09\u306f\u3001\u30b5\u30f3\u30d7\u30eb1\u30682\u306e\u9593\u306e5%\u306e\u9055\u3044\u3092\u8b58\u5225\u3057\u3066\u3044\u308b\u3053\u3068\u304c\u308f\u304b\u308a\u307e\u3059\u3002\u4e00\u65b9\u3067\u3001\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0 qPCR\uff08\u53f3\u56f3\uff09\u306f\u30b5\u30f3\u30d7\u30eb1\u30683\u306e\u9593\u306e10%\u306e\u9055\u3044\u3092\u8b58\u5225\u3067\u304d\u307e\u305b\u3093\u3067\u3057\u305f\u3002<\/p>\n<h2>\u30a6\u30a3\u30eb\u30b9\u306e\u7d76\u5bfe\u5b9a\u91cf<\/h2>\n<p>\u75c5\u539f\u4f53\u30a6\u30a3\u30eb\u30b9\u306e\u529b\u4fa1\u6e2c\u5b9a\u306e\u4ee3\u7528\u3068\u3057\u3066\u3001\u751f\u4f53\u30b5\u30f3\u30d7\u30eb\u4e2d\u306e<a href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/life-science\/pcr\/digital-pcr\/quantstudio-3d-applications\/absolute-quantification-viral-load.html?CID=gsd_pcr_sbu_r04_jp_cp0000_pjt0000_gsd00000_0so_blg_op_awa_oc_s00_qpcr41_Social_LAB\" target=\"_blank\" rel=\"noopener noreferrer\">\u30a6\u30a3\u30eb\u30b9\u30b3\u30d4\u30fc\u6570\u306e\u7d76\u5bfe\u5b9a\u91cf<\/a>\u304c\u884c\u308f\u308c\u3066\u3044\u307e\u3059\u3002\u3057\u304b\u3057\u3001<strong>\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u3092\u7528\u3044\u305f\u30a6\u30a3\u30eb\u30b9\u91cf\u306e\u6e2c\u5b9a\u3067\u306f\u30a2\u30c3\u30bb\u30a4\u306e\u5897\u5e45\u52b9\u7387\u3084\u6a5f\u5668\u306e\u30ad\u30e3\u30ea\u30d6\u30ec\u30fc\u30b7\u30e7\u30f3\u306e\u72b6\u614b\u306e\u5f71\u97ff\u3092\u53d7\u3051\u308b\u3053\u3068\u3084\u3001\u672a\u77e5\u306e\u30b5\u30f3\u30d7\u30eb\u306eCt\u5024\u304b\u3089\u7d76\u5bfe\u5024\u3092\u6c42\u3081\u308b\u306b\u306f\u6a19\u6e96\u30b5\u30f3\u30d7\u30eb\u3068\u306e\u6bd4\u8f03\u304c\u5fc5\u8981\u3001\u3068\u3044\u3063\u305f\u8ab2\u984c\u3092\u30af\u30ea\u30a2\u3059\u308b\u3053\u3068\u304c\u6c42\u3081\u3089\u308c\u307e\u3059<\/strong>\u3002<\/p>\n<p>\u305d\u308c\u306b\u5bfe\u3057\u3001\u30c7\u30b8\u30bf\u30ebPCR\u306f\u5897\u5e45\u9014\u4e2d\u306e\u5dee\u306f\u7d50\u679c\u306b\u5f71\u97ff\u3057\u307e\u305b\u3093\u3002\u4ee3\u308f\u308a\u306b\u3001<strong>\u30c7\u30b8\u30bf\u30ebPCR\u3067\u306f\u3001\u30b5\u30f3\u30d7\u30eb\u3092\u5897\u5e45\u524d\u306b\u4f55\u5343\u3082\u306e\u500b\u3005\u306e\u30a8\u30f3\u30c9\u30dd\u30a4\u30f3\u30c8PCR\u53cd\u5fdc\u30a6\u30a7\u30eb\u306b\u5206\u914d\u3057\u3001\u5bfe\u8c61\u306e\u30a6\u30a3\u30eb\u30b9\u914d\u5217\u306e\u5897\u5e45\u306e\u6709\u7121\u306b\u3088\u3063\u3066\u967d\u6027\u307e\u305f\u306f\u9670\u6027\u304b\u30a6\u30a7\u30eb\u6bce\u306b\u5224\u5b9a\u3057\u307e\u3059\u3002\u9670\u6027\u3068\u306a\u3063\u305f\u30a6\u30a7\u30eb\u306e\u6570\u304b\u3089\u3001\u5143\u306e\u30b5\u30f3\u30d7\u30eb\u4e2d\u306e\u30a6\u30a3\u30eb\u30b9\u6fc3\u5ea6\u3092\u7b97\u51fa\u3057\u307e\u3059<\/strong>\u3002<\/p>\n<p>\u5404\u53cd\u5fdc\u304c\u967d\u6027\u304b\u9670\u6027\u304b\u306e\u307f\u5224\u5b9a\u3059\u308b\u30c7\u30b8\u30bf\u30ebPCR\u306e\u6e2c\u5b9a\u7cfb\u3067\u306f\u3001\u6e2c\u5b9a\u5024\u304c\u30a2\u30c3\u30bb\u30a4\u306e\u52b9\u7387\u3084\u6a5f\u5668\u306e\u30ad\u30e3\u30ea\u30d6\u30ec\u30fc\u30b7\u30e7\u30f3\u72b6\u614b\u306e\u9055\u3044\u306e\u5f71\u97ff\u3092\u6700\u5c0f\u9650\u306b\u6291\u3048\u308b\u3053\u3068\u304c\u3067\u304d\u307e\u3059\u3002\u3053\u306e\u3053\u3068\u306b\u3088\u308a\u3001\u5916\u7684\u8981\u56e0\u306e\u5e72\u6e09\u3092\u53d7\u3051\u306a\u3044\u6a19\u6e96\u5316\u3055\u308c\u305f\u30a6\u30a3\u30eb\u30b9\u30b3\u30d4\u30fc\u6570\u306e\u5b9a\u91cf\u7d50\u679c\u304c\u5f97\u3089\u308c\u308b\u306e\u3067\u3001\u305d\u306e\u307e\u307e\u8907\u6570\u306e\u7814\u7a76\u5ba4\u9593\u3067\u30c7\u30fc\u30bf\u3092\u6bd4\u8f03\u3067\u304d\u307e\u3059\u3002<\/p>\n<h2>\u30ea\u30d5\u30a1\u30ec\u30f3\u30b9\u304a\u3088\u3073\u30b9\u30bf\u30f3\u30c0\u30fc\u30c9\u306e\u7d76\u5bfe\u5b9a\u91cf<\/h2>\n<p>\u6b63\u78ba\u306a\u907a\u4f1d\u5b50\u5b9a\u91cf\u306b\u306f\u3001\u591a\u304f\u306e\u5834\u5408\u3001\u30ea\u30d5\u30a1\u30ec\u30f3\u30b9\u30b5\u30f3\u30d7\u30eb\u3084\u30a2\u30c3\u30bb\u30a4\u30b9\u30bf\u30f3\u30c0\u30fc\u30c9\u3068\u306e\u6bd4\u8f03\u304c\u5fc5\u8981\u3067\u3059\u3002\u305f\u3060\u5b9f\u969b\u306b\u306f\u3001\u9069\u5207\u306a\u30ea\u30d5\u30a1\u30ec\u30f3\u30b9\u30b5\u30f3\u30d7\u30eb\u304c\u7121\u3044\u30b1\u30fc\u30b9\u304c\u591a\u3005\u3042\u308a\u307e\u3059\uff08\u751f\u7269\u7a2e\u306e\u554f\u984c\u3084\u3001\u7279\u5b9a\u75be\u60a3\u306b\u304a\u3044\u3066\u7279\u7570\u7684\u306a\u907a\u4f1d\u5b50\u306a\u3069\u304c\u8a72\u5f53\u3057\u307e\u3059\uff09\u3002<strong>\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u3092\u7528\u3044\u3066\u30ea\u30d5\u30a1\u30ec\u30f3\u30b9\u30b5\u30f3\u30d7\u30eb\u3092\u4f5c\u6210\u3059\u308b\u5834\u5408\u3001\u30ea\u30d5\u30a1\u30ec\u30f3\u30b9\u30b5\u30f3\u30d7\u30eb\u306e\u521d\u3081\u306e\u8f03\u6b63\u65b9\u6cd5\u3084\u3001\u9577\u671f\u5b89\u5b9a\u6027\u306e\u78ba\u8a8d\u3001\u304a\u3088\u3073\u5168\u3066\u306e\u7814\u7a76\u3092\u5b8c\u4e86\u3059\u308b\u306e\u306b\u5341\u5206\u306a\u91cf\u304c\u3042\u308b\u304b\u306a\u3069\u306e\u6761\u4ef6\u691c\u8a0e\u304c\u5fc5\u8981<\/strong>\u3067\u3059\u3002\u3055\u3089\u306b\u3001\u5171\u901a\u306e\u6a19\u6e96\u30b9\u30bf\u30f3\u30c0\u30fc\u30c9\u3092\u4f7f\u7528\u3057\u3066\u3044\u306a\u3051\u308c\u3070\u3001\u7814\u7a76\u5ba4\u9593\u306e\u30c7\u30fc\u30bf\u6bd4\u8f03\u3082\u305d\u306e\u307e\u307e\u884c\u3046\u3053\u3068\u306b\u306f\u652f\u969c\u304c\u751f\u3058\u307e\u3059\u3002<\/p>\n<div id=\"attachment_1160\" style=\"width: 534px\" class=\"wp-caption aligncenter\"><a href=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/digitalpcr6-fig3.jpg\" rel=\"attachment wp-att-1160\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-1160\" class=\"size-full wp-image-1160\" src=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/digitalpcr6-fig3.jpg\" alt=\"digitalpcr6-fig3\" width=\"524\" height=\"167\" \/><\/a><p id=\"caption-attachment-1160\" class=\"wp-caption-text\">\u30c7\u30b8\u30bf\u30eb PCR\u306b\u3088\u308b\u9ad8\u7cbe\u5ea6\u3067\u6b63\u78ba\u306a\u30b9\u30bf\u30f3\u30c0\u30fc\u30c9\u306e\u5b9a\u91cf<\/p><\/div>\n<p>\u8aac\u660e: A: 4\u7a2e\u985e\u306e\u30b9\u30bf\u30f3\u30c0\u30fc\u30c9\u30b5\u30f3\u30d7\u30eb\u3092dPCR\u3067\u6e2c\u5b9a\uff08n=2\uff09\u3002\u3070\u3089\u3064\u304d\u304c\u5c11\u306a\u304f\u3001\u7cbe\u5ea6\u304c\u975e\u5e38\u306b\u9ad8\u3044\u5b9a\u91cf\u5024\u304c\u5f97\u3089\u308c\u307e\u3057\u305f\u3002B: \u30b5\u30f3\u30d7\u30eb600-T\u3092\u7528\u3044\u3066\u30014\u6bb5\u968e\u306e10\u500d\u5e0c\u91c8\u7cfb\u5217\u3092\u4f5c\u6210\u3001\u6e2c\u5b9a\u3057\u305f\u7d50\u679c\u3002\u5e0c\u91c8\u500d\u7387\u3068\u5b9a\u91cf\u5024\u306e\u9593\u306b\u306f\u9ad8\u3044\u76f8\u95a2\u6027\uff080.9991\uff09\u304c\u3042\u308a\u3001\u5404\u5e0c\u91c8\u6bb5\u968e\u306b\u304a\u3044\u3066\u3001\u9ad8\u3044\u7cbe\u5ea6\u306e\u5b9a\u91cf\u5024\u3092\u5f97\u308b\u3053\u3068\u304c\u3067\u304d\u307e\u3057\u305f\u3002<\/p>\n<p><strong>\u30c7\u30b8\u30bf\u30ebPCR\u306f\u3001\u76f4\u63a5<a href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/life-science\/pcr\/digital-pcr\/quantstudio-3d-applications\/absolute-quantification-references-standards.html?CID=gsd_pcr_sbu_r04_jp_cp0000_pjt0000_gsd00000_0so_blg_op_awa_oc_s00_qpcr41_Social_LAB\" target=\"_blank\" rel=\"noopener noreferrer\">\u30bf\u30fc\u30b2\u30c3\u30c8\u907a\u4f1d\u5b50\u306e\u30b3\u30d4\u30fc\u6570\u3092\u6c42\u3081\u308b\u7d76\u5bfe\u5b9a\u91cf<\/a>\u3092\u884c\u3046\u3053\u3068\u304c\u3067\u304d\u308b\u306e\u3067\u3001\u65b0\u898f\u306e\u30ea\u30d5\u30a1\u30ec\u30f3\u30b9\u30b5\u30f3\u30d7\u30eb\u3092\u4f5c\u6210\u3059\u308b\u6642\u306e\u8f03\u6b63\u4f5c\u696d\u306b\u6709\u52b9\u6d3b\u7528\u3057\u3066\u3044\u305f\u3060\u304f\u3053\u3068\u304c\u3067\u304d\u307e\u3059<\/strong>\u3002\u30b3\u30d4\u30fc\u6570\u304c\u660e\u78ba\u306a\u30ea\u30d5\u30a1\u30ec\u30f3\u30b9\u30b5\u30f3\u30d7\u30eb\u3092\u5171\u901a\u3067\u7528\u3044\u308b\u3053\u3068\u306b\u3088\u308a\u3001\u76f4\u63a5\u7d50\u679c\u3092\u6bd4\u8f03\u3059\u308b\u3053\u3068\u304c\u53ef\u80fd\u3067\u3059\u3002<\/p>\n<h2>\u307e\u3068\u3081<\/h2>\n<p>6\u56de\u30b7\u30ea\u30fc\u30ba\u306e\u6700\u7d42\u56de\u3067\u304a\u4f1d\u3048\u3057\u305f\u3044\u3053\u3068\u3001\u305d\u308c\u306f\u3001<strong>\u30c7\u30b8\u30bf\u30ebPCR\u306f\u9ad8\u611f\u5ea6\u30fb\u9ad8\u7cbe\u5ea6\u306a\u7d76\u5bfe\u5b9a\u91cf\u3092\u884c\u3046\u3053\u3068\u304c\u3067\u304d\u308b\u306e\u3067\u3001\u69d8\u3005\u306a\u30a2\u30d7\u30ea\u30b1\u30fc\u30b7\u30e7\u30f3\u306b\u304a\u3044\u3066\u30a2\u30c3\u30bb\u30a4\u306e\u30d1\u30d5\u30a9\u30fc\u30de\u30f3\u30b9\u306e\u6700\u9069\u5316\u3092\u6709\u52b9\u306b\u884c\u3046\u3053\u3068\u304c\u3067\u304d\u308b<\/strong>\u3001\u3068\u3044\u3046\u3053\u3068\u3067\u3059\u3002\u305f\u3068\u3048\u3070\u3001<strong>\u5fae\u91cf\u306e\u75c5\u539f\u83cc\u306e\u691c\u51fa\u5b9a\u91cf\u3084\u3001\u907a\u4f1d\u5b50\u7d44\u307f\u63db\u3048\u4f5c\u7269(GMO)\u691c\u51fa\u3001\u304a\u3088\u3073\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u5b9f\u9a13\u306b\u4f7f\u7528\u3059\u308b\u6a19\u6e96\u30b5\u30f3\u30d7\u30eb\u306e\u7d76\u5bfe\u5b9a\u91cf\u7b49\u306b\u6709\u7528\u3067\u3059<\/strong>\u3002<\/p>\n<h3>\u3010\u7121\u6599\u30c0\u30a6\u30f3\u30ed\u30fc\u30c9\u3011\u30c7\u30b8\u30bf\u30ebPCR\u30a2\u30d7\u30ea\u30b1\u30fc\u30b7\u30e7\u30f3\u30ac\u30a4\u30c9<\/h3>\n<p>\u30c7\u30b8\u30bf\u30ebPCR\u306b\u3088\u308b\u5b9a\u91cf\u304c\u6709\u7528\u306a\u8907\u6570\u306e\u30a2\u30d7\u30ea\u30b1\u30fc\u30b7\u30e7\u30f3\u306b\u3064\u3044\u3066\u7d39\u4ecb\u3057\u3066\u3044\u307e\u3059\u3002\u3053\u308c\u304b\u3089\u30c7\u30b8\u30bf\u30ebPCR\u5b9f\u9a13\u3092\u8003\u3048\u3066\u3044\u308b\u65b9\u306b\u6700\u9069\u3067\u3059\u3002<\/p>\n<p><a class=\"btn btn-red\" href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/global\/forms\/life-science\/dpcr-applications-ebook-jp.html?CID=gsd_pcr_sbu_r04_jp_cp0000_pjt0000_gsd00000_0so_blg_op_awa_oc_s00_qpcr41_Social_LAB\" target=\"_blank\" rel=\"noopener\">\u30c0\u30a6\u30f3\u30ed\u30fc\u30c9\u306f\u3053\u3061\u3089<\/a><br \/>\n&nbsp;<\/p>\n<p>\u7814\u7a76\u7528\u306b\u306e\u307f\u4f7f\u7528\u3067\u304d\u307e\u3059\u3002\u8a3a\u65ad\u76ee\u7684\u304a\u3088\u3073\u305d\u306e\u624b\u7d9a\u304d\u4e0a\u3067\u306e\u4f7f\u7528\u306f\u3067\u304d\u307e\u305b\u3093\u3002<\/p>\n","protected":false},"excerpt":{"rendered":"<p>\u30c7\u30b8\u30bf\u30ebPCR (dPCR) \u3092\u7d39\u4ecb\u3057\u3066\u3044\u308b6\u90e8\u69cb\u6210\u30b7\u30ea\u30fc\u30ba\u306e\u6700\u5f8c\u3068\u306a\u308b\u3053\u306e\u30d1\u30fc\u30c8\u3067\u306f\u3001\u7d76\u5bfe\u5b9a\u91cf\u3084\u30ec\u30a2\u306a\u914d\u5217\u306e\u691c\u51fa\u304c\u53ef\u80fd\u306a\u30c7\u30b8\u30bf\u30ebPCR\u306e\u5229\u70b9\u3092\u6d3b\u7528\u3057\u305f\u3001\u69d8\u3005\u306a\u30a2\u30d7\u30ea\u30b1\u30fc\u30b7\u30e7\u30f3\u306e\u4e8b\u4f8b\u306b\u3064\u3044\u3066\u3054\u7d39\u4ecb\u3057\u307e\u3059\u3002<\/p>\n","protected":false},"author":988,"featured_media":2612,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_monsterinsights_skip_tracking":false,"_genesis_hide_title":false,"_genesis_hide_breadcrumbs":false,"_genesis_hide_singular_image":false,"_genesis_hide_footer_widgets":false,"_genesis_custom_body_class":"","_genesis_custom_post_class":"","_genesis_layout":"","_jetpack_newsletter_access":"","_jetpack_dont_email_post_to_subs":false,"_jetpack_newsletter_tier_id":0,"_jetpack_memberships_contains_paywalled_content":false,"_jetpack_hide_featured_image":false,"_jetpack_featured_image_duplicate_dismissed":0,"_jetpack_feature_clip_id":0,"_jetpack_memberships_contains_paid_content":false,"footnotes":"","jetpack_post_was_ever_published":false},"categories":[156],"tags":[44],"division":[],"class_list":["post-381","post","type-post","status-publish","format-standard","has-post-thumbnail","category-mol-bio","tag-digital-pcr","entry"],"_selected_authors":[],"_selected_reviewers":[],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v28.9 (Yoast SEO v28.9) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>\u7d76\u5bfe\u5b9a\u91cf\u3084\u30ec\u30a2\u306a\u914d\u5217\u306e\u691c\u51fa\u304c\u53ef\u80fd\u306a\u30c7\u30b8\u30bf\u30ebPCR\u306e\u5229\u70b9\u3092\u6d3b\u7528\u3057\u305f\u69d8\u3005\u306a\u30a2\u30d7\u30ea\u30b1\u30fc\u30b7\u30e7\u30f3\u306e\u4e8b\u4f8b\u307e\u3068\u3081 - Learning at the Bench<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/digitalpcr6\/\" \/>\n<meta property=\"og:locale\" content=\"ja_JP\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"\u7d76\u5bfe\u5b9a\u91cf\u3084\u30ec\u30a2\u306a\u914d\u5217\u306e\u691c\u51fa\u304c\u53ef\u80fd\u306a\u30c7\u30b8\u30bf\u30ebPCR\u306e\u5229\u70b9\u3092\u6d3b\u7528\u3057\u305f\u69d8\u3005\u306a\u30a2\u30d7\u30ea\u30b1\u30fc\u30b7\u30e7\u30f3\u306e\u4e8b\u4f8b\u307e\u3068\u3081\" \/>\n<meta property=\"og:description\" content=\"\u30c7\u30b8\u30bf\u30ebPCR (dPCR) \u3092\u7d39\u4ecb\u3057\u3066\u3044\u308b6\u90e8\u69cb\u6210\u30b7\u30ea\u30fc\u30ba\u306e\u6700\u5f8c\u3068\u306a\u308b\u3053\u306e\u30d1\u30fc\u30c8\u3067\u306f\u3001\u7d76\u5bfe\u5b9a\u91cf\u3084\u30ec\u30a2\u306a\u914d\u5217\u306e\u691c\u51fa\u304c\u53ef\u80fd\u306a\u30c7\u30b8\u30bf\u30ebPCR\u306e\u5229\u70b9\u3092\u6d3b\u7528\u3057\u305f\u3001\u69d8\u3005\u306a\u30a2\u30d7\u30ea\u30b1\u30fc\u30b7\u30e7\u30f3\u306e\u4e8b\u4f8b\u306b\u3064\u3044\u3066\u3054\u7d39\u4ecb\u3057\u307e\u3059\u3002\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/digitalpcr6\/\" \/>\n<meta property=\"og:site_name\" content=\"Learning at the Bench\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/ThermoFisherJapan\" \/>\n<meta property=\"article:published_time\" content=\"2016-05-11T15:00:00+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2025-07-01T08:08:10+00:00\" \/>\n<meta property=\"og:image\" content=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/digitalpcr-title-5.jpeg\" \/>\n\t<meta property=\"og:image:width\" content=\"600\" \/>\n\t<meta property=\"og:image:height\" content=\"315\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"LATB Staff\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:creator\" content=\"@ThermoFisherJP\" \/>\n<meta name=\"twitter:site\" content=\"@ThermoFisherJP\" \/>\n<meta name=\"twitter:label1\" content=\"\u57f7\u7b46\u8005\" \/>\n\t<meta name=\"twitter:data1\" content=\"LATB Staff\" \/>\n\t<meta name=\"twitter:label2\" content=\"\u63a8\u5b9a\u8aad\u307f\u53d6\u308a\u6642\u9593\" \/>\n\t<meta name=\"twitter:data2\" content=\"13\u5206\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/digitalpcr6\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/digitalpcr6\\\/\"},\"author\":{\"name\":\"LATB Staff\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#\\\/schema\\\/person\\\/201e6a5abb838fa34e8ff0174b015d36\"},\"headline\":\"\u7d76\u5bfe\u5b9a\u91cf\u3084\u30ec\u30a2\u306a\u914d\u5217\u306e\u691c\u51fa\u304c\u53ef\u80fd\u306a\u30c7\u30b8\u30bf\u30ebPCR\u306e\u5229\u70b9\u3092\u6d3b\u7528\u3057\u305f\u69d8\u3005\u306a\u30a2\u30d7\u30ea\u30b1\u30fc\u30b7\u30e7\u30f3\u306e\u4e8b\u4f8b\u307e\u3068\u3081\",\"datePublished\":\"2016-05-11T15:00:00+00:00\",\"dateModified\":\"2025-07-01T08:08:10+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/digitalpcr6\\\/\"},\"wordCount\":138,\"commentCount\":0,\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/digitalpcr6\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2019\\\/07\\\/digitalpcr-title-5.jpeg\",\"keywords\":[\"\u30c7\u30b8\u30bf\u30ebPCR\"],\"articleSection\":[\"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023\"],\"inLanguage\":\"ja\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/digitalpcr6\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/digitalpcr6\\\/\",\"url\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/digitalpcr6\\\/\",\"name\":\"\u7d76\u5bfe\u5b9a\u91cf\u3084\u30ec\u30a2\u306a\u914d\u5217\u306e\u691c\u51fa\u304c\u53ef\u80fd\u306a\u30c7\u30b8\u30bf\u30ebPCR\u306e\u5229\u70b9\u3092\u6d3b\u7528\u3057\u305f\u69d8\u3005\u306a\u30a2\u30d7\u30ea\u30b1\u30fc\u30b7\u30e7\u30f3\u306e\u4e8b\u4f8b\u307e\u3068\u3081 - Learning at the Bench\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/digitalpcr6\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/digitalpcr6\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2019\\\/07\\\/digitalpcr-title-5.jpeg\",\"datePublished\":\"2016-05-11T15:00:00+00:00\",\"dateModified\":\"2025-07-01T08:08:10+00:00\",\"author\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#\\\/schema\\\/person\\\/201e6a5abb838fa34e8ff0174b015d36\"},\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/digitalpcr6\\\/#breadcrumb\"},\"inLanguage\":\"ja\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/digitalpcr6\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"ja\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/digitalpcr6\\\/#primaryimage\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2019\\\/07\\\/digitalpcr-title-5.jpeg\",\"contentUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2019\\\/07\\\/digitalpcr-title-5.jpeg\",\"width\":600,\"height\":315,\"caption\":\"digitalpcr-title\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/digitalpcr6\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"\u7d76\u5bfe\u5b9a\u91cf\u3084\u30ec\u30a2\u306a\u914d\u5217\u306e\u691c\u51fa\u304c\u53ef\u80fd\u306a\u30c7\u30b8\u30bf\u30ebPCR\u306e\u5229\u70b9\u3092\u6d3b\u7528\u3057\u305f\u69d8\u3005\u306a\u30a2\u30d7\u30ea\u30b1\u30fc\u30b7\u30e7\u30f3\u306e\u4e8b\u4f8b\u307e\u3068\u3081\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#website\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/\",\"name\":\"Learning at the Bench\",\"description\":\"\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"ja\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#\\\/schema\\\/person\\\/201e6a5abb838fa34e8ff0174b015d36\",\"name\":\"LATB Staff\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"ja\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/8803277856c8b753feb4217dff0f9953327452df1a615c3c88b2f9864efb2ddd?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/8803277856c8b753feb4217dff0f9953327452df1a615c3c88b2f9864efb2ddd?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/8803277856c8b753feb4217dff0f9953327452df1a615c3c88b2f9864efb2ddd?s=96&d=mm&r=g\",\"caption\":\"LATB Staff\"},\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/author\\\/latbstaff\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"\u7d76\u5bfe\u5b9a\u91cf\u3084\u30ec\u30a2\u306a\u914d\u5217\u306e\u691c\u51fa\u304c\u53ef\u80fd\u306a\u30c7\u30b8\u30bf\u30ebPCR\u306e\u5229\u70b9\u3092\u6d3b\u7528\u3057\u305f\u69d8\u3005\u306a\u30a2\u30d7\u30ea\u30b1\u30fc\u30b7\u30e7\u30f3\u306e\u4e8b\u4f8b\u307e\u3068\u3081 - Learning at the Bench","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/digitalpcr6\/","og_locale":"ja_JP","og_type":"article","og_title":"\u7d76\u5bfe\u5b9a\u91cf\u3084\u30ec\u30a2\u306a\u914d\u5217\u306e\u691c\u51fa\u304c\u53ef\u80fd\u306a\u30c7\u30b8\u30bf\u30ebPCR\u306e\u5229\u70b9\u3092\u6d3b\u7528\u3057\u305f\u69d8\u3005\u306a\u30a2\u30d7\u30ea\u30b1\u30fc\u30b7\u30e7\u30f3\u306e\u4e8b\u4f8b\u307e\u3068\u3081","og_description":"\u30c7\u30b8\u30bf\u30ebPCR (dPCR) \u3092\u7d39\u4ecb\u3057\u3066\u3044\u308b6\u90e8\u69cb\u6210\u30b7\u30ea\u30fc\u30ba\u306e\u6700\u5f8c\u3068\u306a\u308b\u3053\u306e\u30d1\u30fc\u30c8\u3067\u306f\u3001\u7d76\u5bfe\u5b9a\u91cf\u3084\u30ec\u30a2\u306a\u914d\u5217\u306e\u691c\u51fa\u304c\u53ef\u80fd\u306a\u30c7\u30b8\u30bf\u30ebPCR\u306e\u5229\u70b9\u3092\u6d3b\u7528\u3057\u305f\u3001\u69d8\u3005\u306a\u30a2\u30d7\u30ea\u30b1\u30fc\u30b7\u30e7\u30f3\u306e\u4e8b\u4f8b\u306b\u3064\u3044\u3066\u3054\u7d39\u4ecb\u3057\u307e\u3059\u3002","og_url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/digitalpcr6\/","og_site_name":"Learning at the Bench","article_publisher":"https:\/\/www.facebook.com\/ThermoFisherJapan","article_published_time":"2016-05-11T15:00:00+00:00","article_modified_time":"2025-07-01T08:08:10+00:00","og_image":[{"width":600,"height":315,"url":"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/digitalpcr-title-5.jpeg","type":"image\/jpeg"}],"author":"LATB Staff","twitter_card":"summary_large_image","twitter_creator":"@ThermoFisherJP","twitter_site":"@ThermoFisherJP","twitter_misc":{"\u57f7\u7b46\u8005":"LATB Staff","\u63a8\u5b9a\u8aad\u307f\u53d6\u308a\u6642\u9593":"13\u5206"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/digitalpcr6\/#article","isPartOf":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/digitalpcr6\/"},"author":{"name":"LATB Staff","@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#\/schema\/person\/201e6a5abb838fa34e8ff0174b015d36"},"headline":"\u7d76\u5bfe\u5b9a\u91cf\u3084\u30ec\u30a2\u306a\u914d\u5217\u306e\u691c\u51fa\u304c\u53ef\u80fd\u306a\u30c7\u30b8\u30bf\u30ebPCR\u306e\u5229\u70b9\u3092\u6d3b\u7528\u3057\u305f\u69d8\u3005\u306a\u30a2\u30d7\u30ea\u30b1\u30fc\u30b7\u30e7\u30f3\u306e\u4e8b\u4f8b\u307e\u3068\u3081","datePublished":"2016-05-11T15:00:00+00:00","dateModified":"2025-07-01T08:08:10+00:00","mainEntityOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/digitalpcr6\/"},"wordCount":138,"commentCount":0,"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/digitalpcr6\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/digitalpcr-title-5.jpeg","keywords":["\u30c7\u30b8\u30bf\u30ebPCR"],"articleSection":["\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023"],"inLanguage":"ja","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/digitalpcr6\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/digitalpcr6\/","url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/digitalpcr6\/","name":"\u7d76\u5bfe\u5b9a\u91cf\u3084\u30ec\u30a2\u306a\u914d\u5217\u306e\u691c\u51fa\u304c\u53ef\u80fd\u306a\u30c7\u30b8\u30bf\u30ebPCR\u306e\u5229\u70b9\u3092\u6d3b\u7528\u3057\u305f\u69d8\u3005\u306a\u30a2\u30d7\u30ea\u30b1\u30fc\u30b7\u30e7\u30f3\u306e\u4e8b\u4f8b\u307e\u3068\u3081 - Learning at the Bench","isPartOf":{"@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/digitalpcr6\/#primaryimage"},"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/digitalpcr6\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/digitalpcr-title-5.jpeg","datePublished":"2016-05-11T15:00:00+00:00","dateModified":"2025-07-01T08:08:10+00:00","author":{"@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#\/schema\/person\/201e6a5abb838fa34e8ff0174b015d36"},"breadcrumb":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/digitalpcr6\/#breadcrumb"},"inLanguage":"ja","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/digitalpcr6\/"]}]},{"@type":"ImageObject","inLanguage":"ja","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/digitalpcr6\/#primaryimage","url":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/digitalpcr-title-5.jpeg","contentUrl":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/digitalpcr-title-5.jpeg","width":600,"height":315,"caption":"digitalpcr-title"},{"@type":"BreadcrumbList","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/digitalpcr6\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/"},{"@type":"ListItem","position":2,"name":"\u7d76\u5bfe\u5b9a\u91cf\u3084\u30ec\u30a2\u306a\u914d\u5217\u306e\u691c\u51fa\u304c\u53ef\u80fd\u306a\u30c7\u30b8\u30bf\u30ebPCR\u306e\u5229\u70b9\u3092\u6d3b\u7528\u3057\u305f\u69d8\u3005\u306a\u30a2\u30d7\u30ea\u30b1\u30fc\u30b7\u30e7\u30f3\u306e\u4e8b\u4f8b\u307e\u3068\u3081"}]},{"@type":"WebSite","@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#website","url":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/","name":"Learning at the Bench","description":"","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"ja"},{"@type":"Person","@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#\/schema\/person\/201e6a5abb838fa34e8ff0174b015d36","name":"LATB Staff","image":{"@type":"ImageObject","inLanguage":"ja","@id":"https:\/\/secure.gravatar.com\/avatar\/8803277856c8b753feb4217dff0f9953327452df1a615c3c88b2f9864efb2ddd?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/8803277856c8b753feb4217dff0f9953327452df1a615c3c88b2f9864efb2ddd?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/8803277856c8b753feb4217dff0f9953327452df1a615c3c88b2f9864efb2ddd?s=96&d=mm&r=g","caption":"LATB Staff"},"url":"https:\/\/admin.acceleratingscience.com\/author\/latbstaff\/"}]}},"taxonomy_info":{"category":[{"value":156,"label":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023"}],"post_tag":[{"value":44,"label":"\u30c7\u30b8\u30bf\u30ebPCR"}]},"featured_image_src_large":["https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/digitalpcr-title-5.jpeg",600,315,false],"author_info":{"display_name":"LATB Staff","author_link":"https:\/\/admin.acceleratingscience.com\/author\/latbstaff\/"},"comment_info":0,"category_info":[{"term_id":156,"name":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","slug":"mol-bio","term_group":0,"term_taxonomy_id":156,"taxonomy":"category","description":"","parent":0,"count":540,"filter":"raw","meta":[],"cat_ID":156,"category_count":540,"category_description":"","cat_name":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","category_nicename":"mol-bio","category_parent":0}],"tag_info":[{"term_id":44,"name":"\u30c7\u30b8\u30bf\u30ebPCR","slug":"digital-pcr","term_group":0,"term_taxonomy_id":44,"taxonomy":"post_tag","description":"","parent":0,"count":27,"filter":"raw","meta":[]}],"jetpack-related-posts":[{"id":24545,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/digital-pcr-gene-expression-gsd-ts-sd-25082\/","url_meta":{"origin":381,"position":0},"title":"\u3010Absolute Q\u30c7\u30b8\u30bf\u30ebPCR\u30b7\u30b9\u30c6\u30e0\u306e\u6d3b\u7528\u4f8b\u3011\u30df\u30c8\u30b3\u30f3\u30c9\u30ea\u30a2DNA\u306e\u5b9a\u91cf","author":"LatB Staff","date":"2026\u5e741\u670816\u65e5","format":false,"excerpt":"Applied Biosystems\u2122 QuantStudio\u2122 Absolute Q\u2122 \u30c7\u30b8\u30bf\u30ebP\u2026","rel":"","context":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","block_context":{"text":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/mol-bio\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/12\/digital-pcr-gene-expression-gsd-ts-sd-25082_eyecatch.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/12\/digital-pcr-gene-expression-gsd-ts-sd-25082_eyecatch.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/12\/digital-pcr-gene-expression-gsd-ts-sd-25082_eyecatch.jpg?resize=525%2C300&ssl=1 1.5x"},"classes":[]},{"id":25325,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/exosome-gene-expression-ts-r-25019\/","url_meta":{"origin":381,"position":1},"title":"\u3010\u7b2c5\u56de\u3011 &#8220;RNA cargo&#8221;\u306e\u7cbe\u88fd\u3068\u5b9a\u91cf\u89e3\u6790\u300d\uff5emRNA\u306e\u5b9a\u91cf\u89e3\u6790\uff5e","author":"LatB Staff","date":"2026\u5e746\u670811\u65e5","format":false,"excerpt":"\u4eca\u56de\u306f\u3001\u30a8\u30af\u30bd\u30bd\u30fc\u30e0\uff08\u30a8\u30ad\u30bd\u30bd\u30fc\u30e0\uff09\u4e2d\u306emRNA\u306e\u5b9a\u91cf\u89e3\u6790\u306b\u3064\u3044\u3066\u8aac\u660e\u3057\u307e\u3059\u3002\u7b2c3\u56de\u3067\u30a8\u30af\u30bd\u30bd\u30fc\u30e0\u304b\u2026","rel":"","context":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","block_context":{"text":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/mol-bio\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25018_eyecatch-1.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25018_eyecatch-1.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25018_eyecatch-1.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25018_eyecatch-1.jpg?resize=700%2C400&ssl=1 2x"},"classes":[]},{"id":25247,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/exosome-gene-expression-ts-r-25018\/","url_meta":{"origin":381,"position":2},"title":"\u3010\u7b2c4\u56de\u3011&#8221;RNA cargo&#8221;\u306e\u7cbe\u88fd\u3068\u5b9a\u91cf\u89e3\u6790\uff5emiRNA\u306e\u5b9a\u91cf\u89e3\u6790\uff5e","author":"LatB Staff","date":"2026\u5e745\u670829\u65e5","format":false,"excerpt":"\u524d\u56de\uff08\u3010\u7b2c3\u56de\u3011\u201cRNA cargo\u201d\u306e\u7cbe\u88fd\u3068\u5b9a\u91cf\u89e3\u6790\uff09\u3067\u306f\u3001\u30a8\u30af\u30bd\u30bd\u30fc\u30e0 \uff08\u30a8\u30ad\u30bd\u30bd\u30fc\u30e0\uff09 \u304b\u3089\u306e\u2026","rel":"","context":"\u5206\u6790\u30fb\u6e2c\u5b9a\u95a2\u9023","block_context":{"text":"\u5206\u6790\u30fb\u6e2c\u5b9a\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/analysis\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25018_eyecatch-1.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25018_eyecatch-1.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25018_eyecatch-1.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25018_eyecatch-1.jpg?resize=700%2C400&ssl=1 2x"},"classes":[]},{"id":25565,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/exosome-antibody-ts-r-25068\/","url_meta":{"origin":381,"position":3},"title":"\u3010\u7b2c8\u56de\u3011\u30a8\u30af\u30bd\u30bd\u30fc\u30e0\u30b5\u30d6\u30bf\u30a4\u30d7\u306e\u5206\u753b\u6cd5 \uff1a \u30a6\u30a7\u30b9\u30bf\u30f3\u30d6\u30ed\u30c3\u30c8\uff0fqRT-PCR\uff0f\u30b7\u30fc\u30b1\u30f3\u30b9\u89e3\u6790\u306b\u9069\u3057\u305f\u5206\u753b\u65b9\u6cd5","author":"LatB Staff","date":"2026\u5e749\u670829\u65e5","format":false,"excerpt":"\u672c\u7a3f\u3067\u306f\u3001\u30a8\u30af\u30bd\u30bd\u30fc\u30e0\u819c\u4e0a\u306e\u7279\u5b9a\u306e\u30bf\u30f3\u30d1\u30af\u8cea\u3092\u6a19\u7684\u3068\u3057\u305f\u514d\u75ab\u5438\u7740\u6cd5\u306b\u57fa\u3065\u304f\u5206\u753b\u624b\u6cd5\u3092\u7d39\u4ecb\u3057\u307e\u3059\u3002\u30a8\u30af\u2026","rel":"","context":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","block_context":{"text":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/mol-bio\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25019_eyecatch.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25019_eyecatch.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25019_eyecatch.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25019_eyecatch.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25019_eyecatch.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25019_eyecatch.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":24408,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/elemental-analysis-case-introduction-cmd-25076\/","url_meta":{"origin":381,"position":4},"title":"LA-ICP-MS\u3067\u5b9f\u73fe\u3059\u308b\u7c89\u672b\u8a66\u6599\u306e\u8fc5\u901f\u30fb\u9ad8\u611f\u5ea6\u306a\u5143\u7d20\u5206\u6790","author":"LatB Staff","date":"2025\u5e7412\u670812\u65e5","format":false,"excerpt":"\u5316\u5b66\u54c1\u3084\u5de5\u696d\u6750\u6599\u306e\u539f\u6599\u3001\u304a\u3088\u3073\u4e8c\u6b21\u96fb\u6c60\u5411\u3051\u306e\u6a5f\u80fd\u6027\u6750\u6599\u306a\u3069\u3001\u7c89\u672b\u8a66\u6599\u3084\u30bb\u30e9\u30df\u30c3\u30af\u30b9\u6750\u6599\u4e2d\u306e\u5fae\u91cf\u5143\u7d20\u306e\u2026","rel":"","context":"\u5206\u6790\u30fb\u6e2c\u5b9a\u95a2\u9023","block_context":{"text":"\u5206\u6790\u30fb\u6e2c\u5b9a\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/analysis\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/12\/shutterstock_2249094135-scaled.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/12\/shutterstock_2249094135-scaled.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/12\/shutterstock_2249094135-scaled.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/12\/shutterstock_2249094135-scaled.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/12\/shutterstock_2249094135-scaled.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/12\/shutterstock_2249094135-scaled.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":24187,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/ngs-gene-expression-csd-ts-ion-25073\/","url_meta":{"origin":381,"position":5},"title":"\u3010\u3084\u3063\u3066\u307f\u305f\u3011\u5fae\u91cf\u30fb\u5206\u89e3RNA\u306b\u3088\u308b\u767a\u73fe\u89e3\u6790\u306e\u6700\u9069\u89e3\u306f\uff1fRNA-Seq\u3068Ion AmpliSeq Transcriptome\u3092\u6bd4\u3079\u3066\u307f\u305f","author":"LatB Staff","date":"2025\u5e7411\u670828\u65e5","format":false,"excerpt":"\u6b21\u4e16\u4ee3\u30b7\u30fc\u30b1\u30f3\u30b5\u3067\u306e\u767a\u73fe\u89e3\u6790\u306b\u53d6\u308a\u7d44\u3080\u969b\u3001RNA\u30b5\u30f3\u30d7\u30eb\u304c\u300c\u5c11\u306a\u3059\u304e\u308b\u300d\u300c\u5206\u89e3\u3057\u3066\u3044\u308b\u300d\u3068\u3044\u3046\u72b6\u6cc1\u306f\u2026","rel":"","context":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","block_context":{"text":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/mol-bio\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/11\/ngs-gene-expression-csd-ts-ion-25073_eyecatch-scaled.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/11\/ngs-gene-expression-csd-ts-ion-25073_eyecatch-scaled.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/11\/ngs-gene-expression-csd-ts-ion-25073_eyecatch-scaled.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/11\/ngs-gene-expression-csd-ts-ion-25073_eyecatch-scaled.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/11\/ngs-gene-expression-csd-ts-ion-25073_eyecatch-scaled.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/11\/ngs-gene-expression-csd-ts-ion-25073_eyecatch-scaled.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]}],"jetpack_sharing_enabled":true,"amp_enabled":true,"jetpack_featured_media_url":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/digitalpcr-title-5.jpeg","_links":{"self":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/posts\/381","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/users\/988"}],"replies":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/comments?post=381"}],"version-history":[{"count":0,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/posts\/381\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/media\/2612"}],"wp:attachment":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/media?parent=381"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/categories?post=381"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/tags?post=381"},{"taxonomy":"division","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/division?post=381"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}