{"id":388,"date":"2016-05-18T00:00:00","date_gmt":"2016-05-18T00:00:00","guid":{"rendered":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/ion-chromatography-basic\/"},"modified":"2025-03-12T17:04:40","modified_gmt":"2025-03-12T08:04:40","slug":"ion-chromatography-basic","status":"publish","type":"post","link":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/ion-chromatography-basic\/","title":{"rendered":"\u521d\u5fc3\u8005\u5fc5\u898b\uff01\u30a4\u30aa\u30f3\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc\u306e\u57fa\u790e\u77e5\u8b58"},"content":{"rendered":"<h2>\u306f\u3057\u3099\u3081\u306b<\/h2>\n<p><strong><a href=\"http:\/\/www.thermofisher.com\/jp\/ja\/home\/industrial\/chromatography\/ion-chromatography-ic.html?ICID=cmd_ic_r04_jp_ion_chromatography_basic_Social_LAB\" target=\"_blank\" rel=\"noopener noreferrer\">\u30a4\u30aa\u30f3\u30af\u30ed\u30de\u30c8\u30af\u3099\u30e9\u30d5\u30a3\u30fc<\/a><\/strong>\u3068\u306f\u3001<strong>\u6c34\u6eb6\u6db2\u4e2d\u3067\u30a4\u30aa\u30f3\u3068\u3057\u3066\u5b58\u5728\u3057\u3066\u3044\u308b\u7269\u8cea\u3092\u5206\u96e2\u5b9a\u91cf\u3059\u308b\u65b9\u6cd5<\/strong>\u3066\u3099\u3059\u3002\u6c34\u8cea\u5206\u6790\u306a\u3069\u306e\u74b0\u5883\u6e2c\u5b9a\u3084\u3001\u5de5\u696d\u3001\u533b\u85ac\u54c1\u3001\u98df\u54c1\u5206\u91ce\u306e\u54c1\u8cea\u691c\u67fb\u306a\u3069\u5e45\u5e83\u3044\u7528\u9014\u3067\u4f7f\u308f\u308c\u3066\u3044\u307e\u3059\u3002<\/p>\n<p>\u4eca\u56de\u306f\u3001\u3053\u308c\u307e\u3066\u3099\u30a4\u30aa\u30f3\u30af\u30ed\u30de\u30c8\u30af\u3099\u30e9\u30d5\u30a3\u30fc\u306b\u5168\u304f\u63a5\u3059\u308b\u6a5f\u4f1a\u304b\u3099\u306a\u304b\u3063\u305f\u65b9\u306b\u3082\u308f\u304b\u308a\u3084\u3059\u304f\u3001\u30a4\u30aa\u30f3\u30af\u30ed\u30de\u30c8\u30af\u3099\u30e9\u30d5\u30a3\u30fc\u306e\u57fa\u790e\u3092\u3053\u3099\u7d39\u4ecb\u3057\u307e\u3059\u3002<\/p>\n<h2>\u30a4\u30aa\u30f3\u30af\u30ed\u30de\u30c8\u30af\u3099\u30e9\u30d5\u30a3\u30fc\u306e\u7279\u9577<\/h2>\n<ul>\n<li>1\u56de\u306e\u5206\u6790\u3066\u3099\u8907\u6570\u306e\u30a4\u30aa\u30f3\u6210\u5206\u3092\u540c\u6642\u306b\u5206\u6790\u3059\u308b\u3053\u3068\u304b\u3099\u53ef\u80fd\u3066\u3099\u3059\u3002<\/li>\n<li>ppt\u301cppm\u30ec\u30d8\u3099\u30eb\u306e\u30a4\u30aa\u30f3\u6210\u5206\u306e\u5206\u6790\u304b\u3099\u3066\u3099\u304d\u307e\u3059\u3002<\/li>\n<li>NO<sub>2<\/sub><sup>&#8211;<\/sup>\u3001NO<sub>3<\/sub><sup>&#8211;<\/sup>\u306e\u3088\u3046\u306a\u9178\u5316\u72b6\u614b\u306e\u7570\u306a\u308b\u30a4\u30aa\u30f3\u6210\u5206\u3092\u5225\u3005\u306b\u5b9a\u91cf\u3059\u308b\u3053\u3068\u304b\u3099\u3066\u3099\u304d\u307e\u3059\u3002<\/li>\n<li>Fe<sup>2+<\/sup>\u3001Fe<sup>3+<\/sup>\u306e\u3088\u3046\u306a\u4fa1\u6570\u306e\u7570\u306a\u308b\u30a4\u30aa\u30f3\u6210\u5206\u3092\u5225\u3005\u306b\u5b9a\u91cf\u3067\u304d\u307e\u3059\u3002<\/li>\n<li>\u30aa\u30fc\u30c8\u30b5\u30f3\u30d5\u309a\u30e9\u30fc\u3092\u4f7f\u7528\u3059\u308b\u3053\u3068\u3066\u3099\u3001\u3055\u3089\u306a\u308b\u5206\u6790\u306e\u81ea\u52d5\u5316\u304b\u3099\u53ef\u80fd\u3066\u3099\u3059\u3002<\/li>\n<li>\u6e2c\u5b9a\u7d50\u679c\u306b\u500b\u4eba\u5dee\u304b\u3099\u306a\u304f\u3001\u518d\u73fe\u6027\u306b\u512a\u308c\u3066\u3044\u307e\u3059\u3002<\/li>\n<\/ul>\n<h2>\u30a4\u30aa\u30f3\u30af\u30ed\u30de\u30c8\u30af\u3099\u30e9\u30d5\u30a3\u30fc\u3066\u3099\u6e2c\u5b9a\u3066\u3099\u304d\u308b\u6210\u5206<\/h2>\n<p>\u30a4\u30aa\u30f3\u30af\u30ed\u30de\u30c8\u30af\u3099\u30e9\u30d5\u30a3\u30fc\u3066\u3099\u306f\u3001<strong>\u4e3b\u306b\u7121\u6a5f\u306e\u9670\u30a4\u30aa\u30f3\u3068\u967d\u30a4\u30aa\u30f3\u306e\u6e2c\u5b9a<\/strong>\u3092\u884c\u3046\u3053\u3068\u304b\u3099\u3066\u3099\u304d\u307e\u3059\u3002\u307e\u305f\u3001<strong>\u4e00\u90e8\u306e\u6709\u6a5f\u9178\u3084\u30a2\u30df\u30f3\u306e\u6e2c\u5b9a\u3082\u53ef\u80fd<\/strong>\u3066\u3099\u3059\u3002<\/p>\n<p><strong>\u89e3\u96e2\u4e57\u6570\u304b\u30997\u4ee5\u4e0b\u3066\u3099\u3001\u4fa1\u6570\u304b\u30991\u30012\u306e\u30a4\u30aa\u30f3\u304b\u3099\u4e3b\u306a\u6e2c\u5b9a\u5bfe\u8c61<\/strong>\u3067\u3059\u3002\u56f31\u306b\u30a4\u30aa\u30f3\u30af\u30ed\u30de\u30c8\u30af\u3099\u30e9\u30d5\u30a3\u30fc\u3066\u3099\u6e2c\u5b9a\u3066\u3099\u304d\u308b\u6210\u5206\u3092\u8a18\u8f09\u3057\u307e\u3059\u3002<strong>\u8272\u304b\u3099\u4ed8\u3044\u3066\u3044\u308b\u6210\u5206\u306f\u30a4\u30aa\u30f3\u30af\u30ed\u30de\u30c8\u30af\u3099\u30e9\u30d5\u30a3\u30fc\u306b\u3088\u308a\u6e2c\u5b9a\u3066\u3099\u304d\u308b\u3082\u306e\u3066\u3099\u3059\u3002\u3053\u306e\u307b\u304b\u306b\u3082\u4f4e\u7d1a\u8102\u80aa\u9178\u3001\u6709\u6a5f\u7cfb\u30b9\u30eb\u30db\u30f3\u9178\u3001\u91d1\u5c5e\u932f\u30a4\u30aa\u30f3\u3001\u30a2\u30df\u30f3\u985e\u3001\u30a2\u30eb\u30b3\u30fc\u30eb\u985e\u3001\u30a2\u30df\u30ce\u9178\u3001\u7cd6\u30fb\u7cd6\u30a2\u30eb\u30b3\u30fc\u30eb\u306a\u3068\u3099\u306e\u6e2c\u5b9a\u304b\u3099\u53ef\u80fd<\/strong>\u3066\u3099\u3059\u3002<\/p>\n<p><strong>\u4e00\u822c\u7684\u306a\u6e2c\u5b9a\u3066\u3099\u306f<a href=\"http:\/\/www.thermofisher.com\/jp\/ja\/home\/industrial\/chromatography\/ion-chromatography-ic\/ion-chromatography-columns.html?ICID=cmd_ic_r04_jp_ion_chromatography_basic_Social_LAB\" target=\"_blank\" rel=\"noopener noreferrer\">\u30a4\u30aa\u30f3\u4ea4\u63db\u30ab\u30e9\u30e0<\/a>\u3068<a href=\"http:\/\/www.thermofisher.com\/jp\/ja\/home\/industrial\/chromatography\/ion-chromatography-ic\/ic-chromatography-ic-detectors.html?ICID=cmd_ic_r04_jp_ion_chromatography_basic_Social_LAB\" target=\"_blank\" rel=\"noopener noreferrer\">\u96fb\u6c17\u4f1d\u5c0e\u5ea6\u691c\u51fa\u5668<\/a>\u3092\u4f7f\u7528<\/strong>\u3057\u307e\u3059\u304b\u3099\u3001\u6e2c\u5b9a\u9805\u76ee\u306b\u3088\u3063\u3066\u306f\u7570\u306a\u308b\u7a2e\u985e\u306e\u30ab\u30e9\u30e0\u3084\u691c\u51fa\u5668\u3092\u4f7f\u3046\u3053\u3068\u304b\u3099\u3042\u308a\u307e\u3059\u3002<\/p>\n<div id=\"attachment_14575\" style=\"width: 1138px\" class=\"wp-caption aligncenter\"><a href=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2016\/05\/ion-chromatography-basic-fig1r.png\" target=\"_blank\" rel=\"noopener\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-14575\" class=\"wp-image-14575 size-full\" src=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2016\/05\/ion-chromatography-basic-fig1r.png\" alt=\"\u30a4\u30aa\u30f3\u30af\u30ed\u30de\u30c8\u30af\u3099\u30e9\u30d5\u30a3\u30fc\u306e\u5206\u6790\u5bfe\u8c61\u30a4\u30aa\u30f3\u7a2e\" width=\"1128\" height=\"697\" srcset=\"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2016\/05\/ion-chromatography-basic-fig1r.png 1128w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2016\/05\/ion-chromatography-basic-fig1r-300x185.png 300w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2016\/05\/ion-chromatography-basic-fig1r-1024x633.png 1024w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2016\/05\/ion-chromatography-basic-fig1r-768x475.png 768w\" sizes=\"auto, (max-width: 1128px) 100vw, 1128px\" \/><\/a><p id=\"caption-attachment-14575\" class=\"wp-caption-text\">\u56f31 \u30a4\u30aa\u30f3\u30af\u30ed\u30de\u30c8\u30af\u3099\u30e9\u30d5\u30a3\u30fc\u306e\u5206\u6790\u5bfe\u8c61\u30a4\u30aa\u30f3\u7a2e<\/p><\/div>\n<p><strong>\u9670\u30a4\u30aa\u30f3\u3068\u967d\u30a4\u30aa\u30f3\u306f\u305d\u308c\u305d\u3099\u308c\u5206\u6790\u6761\u4ef6\u304b\u3099\u7570\u306a\u308b\u305f\u3081\u30011\u53f0\u306e\u88c5\u7f6e\u3066\u3099\u540c\u6642\u306b\u5206\u6790\u3059\u308b\u3053\u3068\u306f\u3066\u3099\u304d\u307e\u305b\u3093\u304b\u3099\u3001\u540c\u3057\u3099\u96fb\u8377\u306e\u6210\u5206\u3066\u3099\u3042\u308c\u306f\u3099\u540c\u6642\u306b\u5206\u6790\u3066\u3099\u304d\u308b\u5834\u5408\u304b\u3099\u591a\u304f\u3042\u308a\u307e\u3059<\/strong>\u3002<\/p>\n<h2>\u30a4\u30aa\u30f3\u30af\u30ed\u30de\u30c8\u30af\u3099\u30e9\u30d5\u306e\u69cb\u6210<\/h2>\n<p>\u56f32\u306b\u30a4\u30aa\u30f3\u30af\u30ed\u30de\u30c8\u30af\u3099\u30e9\u30d5\u306e\u57fa\u672c\u7684\u306a\u69cb\u6210\u56f3\u3092\u793a\u3057\u307e\u3059\u3002<strong>\u4e00\u822c\u7684\u306b\u30a4\u30aa\u30f3\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u306f\u3001\u6eb6\u96e2\u6db2\u3092\u9001\u308b\u305f\u3081\u306e\u30db\u309a\u30f3\u30d5\u309a\u3001\u30a4\u30f3\u30b7\u3099\u30a7\u30af\u30b7\u30e7\u30f3\u30cf\u3099\u30eb\u30d5\u3099\u3001\u30ab\u30e9\u30e0\u3001\u30b5\u30d5\u309a\u30ec\u30c3\u30b5\u30fc\u3001\u96fb\u6c17\u4f1d\u5c0e\u5ea6\u691c\u51fa\u5668\u3001\u30ef\u30fc\u30af\u30b9\u30c6\u30fc\u30b7\u30e7\u30f3\u304b\u3089\u69cb\u6210\u3055\u308c\u3066\u3044\u307e\u3059<\/strong>\u3002<\/p>\n<p><strong>\u6eb6\u96e2\u6db2\u3001<a href=\"http:\/\/www.thermofisher.com\/jp\/ja\/home\/industrial\/chromatography\/ion-chromatography-ic\/ion-chromatography-columns.html?ICID=cmd_ic_r04_jp_ion_chromatography_basic_Social_LAB\" target=\"_blank\" rel=\"noopener noreferrer\">\u30ab\u30e9\u30e0<\/a>\u3001<a href=\"http:\/\/www.thermofisher.com\/jp\/ja\/home\/industrial\/chromatography\/ion-chromatography-ic\/ic-consumables\/ic-rfic-suppressors.html?ICID=cmd_ic_r04_jp_ion_chromatography_basic_Social_LAB\" target=\"_blank\" rel=\"noopener noreferrer\">\u30b5\u30d5\u309a\u30ec\u30c3\u30b5\u30fc<\/a>\u306e\u7a2e\u985e\u3092\u5909\u3048\u308b\u3053\u3068\u306b\u3088\u308a\u3055\u307e\u3055\u3099\u307e\u306a\u30a4\u30aa\u30f3\u6210\u5206\u306e\u6e2c\u5b9a\u3092\u884c\u3046\u3053\u3068\u304b\u3099\u53ef\u80fd<\/strong>\u3066\u3099\u3059\u3002\u6e2c\u5b9a\u76ee\u7684\u6210\u5206\u306b\u3088\u3063\u3066\u306f\u691c\u51fa\u5668\u3092\u5909\u3048\u308b\u3053\u3068\u3082\u3042\u308a\u307e\u3059\u3002\u8a66\u6599\u6ce8\u5165\u306b<a href=\"http:\/\/www.thermofisher.com\/jp\/ja\/home\/industrial\/chromatography\/ion-chromatography-ic\/ic-autosamplers-injectors.html?ICID=cmd_ic_r04_jp_ion_chromatography_basic_Social_LAB\" target=\"_blank\" rel=\"noopener noreferrer\">\u30aa\u30fc\u30c8\u30b5\u30f3\u30d5\u309a\u30e9\u30fc<\/a>\u3092\u4f7f\u7528\u3059\u308b\u3053\u3068\u3066\u3099\u5206\u6790\u3092\u81ea\u52d5\u5316\u3066\u3099\u304d\u307e\u3059\u3002<\/p>\n<div id=\"attachment_1177\" style=\"width: 963px\" class=\"wp-caption aligncenter\"><a href=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/ion-chromatography-basic-fig2.png\" target=\"_blank\" rel=\"attachment noopener wp-att-1177\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-1177\" class=\"wp-image-1177 size-full\" src=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/ion-chromatography-basic-fig2.png\" alt=\"\u30a4\u30aa\u30f3\u30af\u30ed\u30de\u30c8\u30af\u3099\u30e9\u30d5\u306e\u57fa\u672c\u69cb\u6210\" width=\"953\" height=\"363\" \/><\/a><p id=\"caption-attachment-1177\" class=\"wp-caption-text\">\u56f32:\u30a4\u30aa\u30f3\u30af\u30ed\u30de\u30c8\u30af\u3099\u30e9\u30d5\u306e\u57fa\u672c\u69cb\u6210<\/p><\/div>\n<h2>\u30a4\u30aa\u30f3\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc\u3092\u7528\u3044\u305f\u5b9a\u6027\u30fb\u5b9a\u91cf<\/h2>\n<p>\u30a4\u30aa\u30f3\u30af\u30ed\u30de\u30c8\u30af\u3099\u30e9\u30d5\u30a3\u30fc\u3066\u3099\u306f\u6a19\u6e96\u7269\u8cea\u3068\u5b9f\u8a66\u6599\u3092\u6e2c\u5b9a\u3057\u3001\u6a19\u6e96\u7269\u8cea\u306e\u30d2\u309a\u30fc\u30af\u3068\u5b9f\u8a66\u6599\u306e\u30d2\u309a\u30fc\u30af\u3092\u6bd4\u8f03\u3057\u3066\u5b9a\u6027\u30fb\u5b9a\u91cf\u3092\u884c\u3044\u307e\u3059\u3002<\/p>\n<p>\u4e00\u5b9a\u306e\u5206\u6790\u6761\u4ef6\u306e\u3082\u3068\u3066\u3099\u306f\u3001\u7279\u5b9a\u306e\u6210\u5206\u306e\u30d2\u309a\u30fc\u30af\u306f\u6a19\u6e96\u8a66\u6599\u3001\u5b9f\u8a66\u6599\u306b\u304b\u304b\u308f\u3089\u3059\u3099\u540c\u3057\u3099\u6642\u9593\u306b\u73fe\u308c\u308b\u305f\u3081\u3001<strong>\u30d2\u309a\u30fc\u30af\u306e\u6eb6\u51fa\u6642\u9593\u304b\u3099\u540c\u3057\u3099\u3066\u3099\u3042\u308c\u306f\u3099\u540c\u3057\u3099\u6210\u5206\u3066\u3099\u3042\u308b\u3068\u898b\u306a\u3057\u3066\u5b9a\u6027\u3092\u884c\u3044\u307e\u3059<\/strong>\u3002<\/p>\n<p>\u56f33\u306b\u9670\u30a4\u30aa\u30f3\u6a19\u6e96\u6db2\u3068\u5b9f\u8a66\u6599\u3066\u3099\u3042\u308b\u6c34\u9053\u6c34\u306e\u30af\u30ed\u30de\u30c8\u30af\u3099\u30e9\u30e0\u3092\u793a\u3057\u307e\u3059\u3002\u30d2\u309a\u30fc\u30af\u306e\u9762\u7a4d\u3084\u9ad8\u3055\u306f\u6210\u5206\u6fc3\u5ea6\u306b\u5bfe\u3057\u3066\u5b9a\u91cf\u7684\u306b\u5909\u5316\u3059\u308b\u305f\u3081\u3001\u6a19\u6e96\u6db2\u306e\u30d2\u309a\u30fc\u30af\u9762\u7a4d\u3001\u9ad8\u3055\u3068\u5b9f\u8a66\u6599\u306e\u30d2\u309a\u30fc\u30af\u9762\u7a4d\u3001\u307e\u305f\u306f\u9ad8\u3055\u3092\u6bd4\u8f03\u3057\u3066\u5b9a\u91cf\u3092\u884c\u3044\u307e\u3059\u3002<\/p>\n<p><strong>\u30a4\u30aa\u30f3\u30af\u30ed\u30de\u30c8\u30af\u3099\u30e9\u30d5\u30a3\u30fc\u3092\u7528\u3044\u3066\u5b9a\u6027\u30fb\u5b9a\u91cf\u3092\u884c\u3046\u5834\u5408\u306f\u3001\u6e2c\u5b9a\u76ee\u7684\u6210\u5206\u304b\u3099\u660e\u78ba\u3066\u3099\u3042\u308b\u3053\u3068\u3068\u305d\u306e\u76ee\u7684\u6210\u5206\u306e\u6a19\u6e96\u7269\u8cea\u304b\u3099\u5165\u624b\u3066\u3099\u304d\u308b\u3053\u3068\u304b\u3099\u524d\u63d0<\/strong>\u3067\u3059\u3002\u672a\u77e5\u6210\u5206\u306e\u5b9a\u6027\u306b\u306f\u9069\u3057\u3066\u3044\u307e\u305b\u3093\u304b\u3099\u3001<strong>\u30a4\u30aa\u30f3\u30af\u30ed\u30de\u30c8\u30af\u3099\u30e9\u30d5\u30a3\u30fc\u306e\u691c\u51fa\u5668\u3068\u3057\u3066\u8cea\u91cf\u5206\u6790\u8a08\u3092\u7528\u3044\u308b\u3053\u3068\u3066\u3099\u672a\u77e5\u6210\u5206\u306e\u5b9a\u6027\u304b\u3099\u3066\u3099\u304d\u308b\u5834\u5408\u3082\u3042\u308a\u307e\u3059<\/strong>\u3002<\/p>\n<div id=\"attachment_1178\" style=\"width: 497px\" class=\"wp-caption aligncenter\"><a href=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/ion-chromatography-basic-fig3.png\" target=\"_blank\" rel=\"attachment noopener wp-att-1178\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-1178\" class=\"wp-image-1178 size-full\" src=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/ion-chromatography-basic-fig3.png\" alt=\"\u6a19\u6e96\u6db2\u3068\u5b9f\u8a66\u6599\u306e\u30af\u30ed\u30de\u30c8\u30af\u3099\u30e9\u30e0\" width=\"487\" height=\"412\" \/><\/a><p id=\"caption-attachment-1178\" class=\"wp-caption-text\">\u56f33 \u6a19\u6e96\u6db2\u3068\u5b9f\u8a66\u6599\u306e\u30af\u30ed\u30de\u30c8\u30af\u3099\u30e9\u30e0<\/p><\/div>\n<h2>\u30a4\u30aa\u30f3\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc\u306e\u6e2c\u5b9a\u6fc3\u5ea6\u7bc4\u56f2<\/h2>\n<p>\u30a4\u30aa\u30f3\u30af\u30ed\u30de\u30c8\u30af\u3099\u30e9\u30d5\u30a3\u30fc\u3066\u3099\u306fppt\u301cppm\u306e\u5b9a\u91cf\u304b\u3099\u53ef\u80fd\u3066\u3099\u3059\u304b\u3099\u3001<strong>\u4e00\u822c\u7684\u306a\u6e2c\u5b9a\u6fc3\u5ea6\u7bc4\u56f2\u306f\u6570ppm\u301c\u6570\u5341ppm\u306e\u30ec\u30d8\u3099\u30eb<\/strong>\u3066\u3099\u3059\u3002\u3053\u308c\u3088\u308a\u6fc3\u5ea6\u304b\u3099\u6975\u7aef\u306b\u9ad8\u3044\u5834\u5408\u306f\u8a66\u6599\u3092\u7d14\u6c34\u3066\u3099\u5e0c\u91c8\u3057\u3066\u304b\u3089\u6e2c\u5b9a\u3057\u307e\u3059\u3002\u6fc3\u5ea6\u304b\u3099\u4f4e\u3044\u5834\u5408\u306f\u88c5\u7f6e\u306b\u6ce8\u5165\u3059\u308b\u8a66\u6599\u91cf\u3092\u5897\u3084\u3057\u3066\u5bfe\u5fdc\u3057\u307e\u3059\u3002\u6fc3\u7e2e\u5206\u6790\u306e\u624b\u6cd5\u3092\u7528\u3044\u308b\u3053\u3068\u306b\u3088\u308appt\u30ec\u30d8\u3099\u30eb\u306e\u5b9a\u91cf\u3082\u53ef\u80fd\u3066\u3099\u3059\u3002<\/p>\n<p>\u6e2c\u5b9a\u76ee\u7684\u6210\u5206\u4ee5\u5916\u306e\u6210\u5206\u306e\u6fc3\u5ea6\u304b\u3099\u9ad8\u3044\u8a66\u6599\u306e\u5834\u5408\u306f\u3001\u6e2c\u5b9a\u76ee\u7684\u6210\u5206\u306e\u5b9a\u91cf\u3092\u59a8\u5bb3\u3059\u308b\u3053\u3068\u304b\u3099\u3042\u308b\u305f\u3081\u3001\u5e0c\u91c8\u3092\u884c\u3063\u305f\u308a\u3001\u524d\u51e6\u7406\u3066\u3099\u59a8\u5bb3\u6210\u5206\u3092\u9664\u53bb\u3057\u3066\u304b\u3089\u6e2c\u5b9a\u3057\u307e\u3059\u3002\u5b9a\u91cf\u4e0b\u9650\u5024\u306f\u6210\u5206\u306e\u7a2e\u985e\u3084\u5206\u6790\u6761\u4ef6\u306b\u3088\u3063\u3066\u7570\u306a\u308a\u307e\u3059\u3002<\/p>\n<h2>\u30a4\u30aa\u30f3\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc\u3067\u6e2c\u5b9a\u3067\u304d\u308b\u8a66\u6599<\/h2>\n<p>\u30a4\u30aa\u30f3\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc\u3067\u6e2c\u5b9a\u3067\u304d\u308b\u8a66\u6599\u306f\u3001<strong>\u7d14\u6c34\u306b\u6eb6\u89e3\u3059\u308b\u3082\u306e\u304b\u3099\u57fa\u672c<\/strong>\u3067\u3059\u3002\u9178\u3084\u30a2\u30eb\u30ab\u30ea\u3066\u3099\u6eb6\u89e3\u3066\u3099\u304d\u308b\u3082\u306e\u3084\u30a2\u30eb\u30b3\u30fc\u30eb\u306a\u3068\u3099\u306e\u6709\u6a5f\u6eb6\u5a92\u3066\u3099\u6eb6\u89e3\u3066\u3099\u304d\u308b\u8a66\u6599\u3082\u4e00\u90e8\u5bfe\u8c61\u3067\u3059\u3002\u3057\u304b\u3057\u3001\u6e2c\u5b9a\u76ee\u7684\u6210\u5206\u4ee5\u5916\u306e\u7269\u8cea\u304b\u3099\u5927\u91cf\u306b\u8a66\u6599\u306b\u5165\u3063\u3066\u3044\u308b\u3068\u3001\u5206\u6790\u7cbe\u5ea6\u304b\u3099\u8457\u3057\u304f\u4f4e\u4e0b\u3057\u305f\u308a\u3001\u6e2c\u5b9a\u76ee\u7684\u6210\u5206\u304b\u3099\u59a8\u5bb3\u3092\u53d7\u3051\u3066\u6e2c\u5b9a\u3066\u3099\u304d\u306a\u3044\u3053\u3068\u304b\u3099\u3042\u308a\u307e\u3059\u3002<\/p>\n<p>\u7d14\u6c34\u306b\u6eb6\u89e3\u3057\u306a\u3044\u6cb9\u8102\u3001\u6709\u6a5f\u6eb6\u5a92\u3001\u30bf\u30f3\u30cf\u309a\u30af\u8cea\u306a\u3068\u3099\u306f\u6545\u969c\u306e\u539f\u56e0\u3068\u306a\u308b\u305f\u3081\u3001\u3053\u308c\u3089\u3092\u542b\u3080\u8a66\u6599\u306b\u5bfe\u3057\u3066\u306f\u524d\u51e6\u7406\u3092\u884c\u3044\u3001\u9664\u53bb\u3059\u308b\u5fc5\u8981\u304b\u3099\u3042\u308a\u307e\u3059\u3002\u307e\u305f\u3001\u7d14\u6c34\u306b\u6eb6\u89e3\u3059\u308b\u3082\u306e\u3066\u3099\u3082\u3001\u754c\u9762\u6d3b\u6027\u5264\u3084\u5f37\u3044\u9178\u5316\u80fd\u30fb\u9084\u5143\u80fd\u3092\u6301\u3064\u6210\u5206\u3082\u6545\u969c\u306e\u539f\u56e0\u3068\u306a\u308a\u307e\u3059\u3002<\/p>\n<p>\u8a66\u6599\u304b\u3099\u6c17\u4f53\u306e\u5834\u5408\u306f\u3001\u6db2\u4f53\u306b\u5438\u53ce\u3057\u3066\u304b\u3089\u5438\u53ce\u6db2\u4e2d\u306e\u30a4\u30aa\u30f3\u3092\u6e2c\u5b9a\u3057\u307e\u3059\u3002<\/p>\n<p>\u6a39\u8102\u306e\u3088\u3046\u306a\u6c34\u306b\u6eb6\u89e3\u3057\u306a\u3044\u56fa\u4f53\u306e\u8a66\u6599\u306e\u5834\u5408\u306f\u3001\u71c3\u713c\u3055\u305b\u305f\u5f8c\u306b\u767a\u751f\u3057\u305f\u30ab\u3099\u30b9\u3092\u5438\u53ce\u6db2\u306b\u6355\u96c6\u3057\u3066\u5438\u53ce\u6db2\u4e2d\u306e\u30a4\u30aa\u30f3\u3092\u6e2c\u5b9a\u3059\u308b\u65b9\u6cd5\u3082\u3042\u308a\u307e\u3059\u3002<\/p>\n<h2>\u30a4\u30aa\u30f3\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc\u306e\u6e2c\u5b9a\u6642\u9593<\/h2>\n<p>\u30a4\u30aa\u30f3\u30af\u30ed\u30de\u30c8\u30af\u3099\u30e9\u30d5\u30a3\u30fc\u3066\u3099\u306f\u3001<strong>\u4e00\u822c\u7684\u306b\u8907\u6570\u306e\u6210\u5206\u30921\u56de\u306e\u8a66\u6599\u6ce8\u5165\u3066\u3099\u540c\u6642\u306b\u6e2c\u5b9a\u3059\u308b\u3053\u3068\u304b\u3099\u591a\u3044\u305f\u3081\u30011\u691c\u4f53\u306e\u6e2c\u5b9a\u306f10\u301c30\u5206\u7a0b\u5ea6\u304b\u304b\u308a\u307e\u3059<\/strong>\u3002\u6e2c\u5b9a\u306e\u5185\u5bb9\u306b\u3088\u3063\u3066\u306f\u6570\u5206\u3066\u3099\u7d42\u4e86\u3059\u308b\u5834\u5408\u30841\u6642\u9593\u4ee5\u4e0a\u304b\u304b\u308b\u5834\u5408\u3082\u3042\u308a\u307e\u3059\u3002\u56f34\u306b\u30ab\u30e9\u30e0\u306b\u3088\u308b\u6e2c\u5b9a\u6642\u9593\u306e\u9055\u3044\u3092\u793a\u3057\u307e\u3059\u3002<\/p>\n<div id=\"attachment_1179\" style=\"width: 471px\" class=\"wp-caption aligncenter\"><a href=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/ion-chromatography-basic-fig4.png\" target=\"_blank\" rel=\"attachment noopener wp-att-1179\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-1179\" class=\"wp-image-1179 size-full\" src=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/ion-chromatography-basic-fig4.png\" alt=\"\u30ab\u30e9\u30e0\u306b\u3088\u308b\u6e2c\u5b9a\u6642\u9593\u306e\u9055\u3044\" width=\"461\" height=\"421\" \/><\/a><p id=\"caption-attachment-1179\" class=\"wp-caption-text\">\u56f34 \u30ab\u30e9\u30e0\u306b\u3088\u308b\u6e2c\u5b9a\u6642\u9593\u306e\u9055\u3044<\/p><\/div>\n<h2>\u30a4\u30aa\u30f3\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc\u306e\u6e2c\u5b9a\u539f\u7406<\/h2>\n<p>\u30a4\u30aa\u30f3\u30af\u30ed\u30de\u30c8\u30af\u3099\u30e9\u30d5\u30a3\u30fc\u3066\u3099\u306f\u3001\u30a4\u30aa\u30f3\u6210\u5206\u306e\u5206\u96e2\u306f\u30a4\u30aa\u30f3\u4ea4\u63db\u6a39\u8102\u304b\u3099\u5145\u3066\u3093\u3055\u308c\u305f\u30ab\u30e9\u30e0\u3066\u3099\u884c\u308f\u308c\u307e\u3059\u3002\u8a66\u6599\u6ce8\u5165\u90e8\u304b\u3089\u6ce8\u5165\u3055\u308c\u305f\u8a66\u6599\u306f\u3001\u6eb6\u96e2\u6db2\u306b\u3088\u3063\u3066\u30ab\u30e9\u30e0\u306b\u904b\u306f\u3099\u308c\u307e\u3059\u3002<\/p>\n<p>\u8a66\u6599\u4e2d\u306e\u30a4\u30aa\u30f3\u306f\u3001\u4e00\u65e6\u3001\u30ab\u30e9\u30e0\u5185\u306e\u30a4\u30aa\u30f3\u4ea4\u63db\u6a39\u8102\u306b\u4fdd\u6301\u3055\u308c\u307e\u3059\u304b\u3099\u3001\u6eb6\u96e2\u6db2\u306b\u3088\u3063\u3066\u6d41\u3055\u308c\u30ab\u30e9\u30e0\u5185\u3092\u79fb\u52d5\u3057\u3066\u3044\u304d\u307e\u3059\u3002<\/p>\n<p><strong>\u30a4\u30aa\u30f3\u306e\u4fa1\u6570\u3001\u30a4\u30aa\u30f3\u534a\u5f84\u3001\u758e\u6c34\u6027\u306a\u3068\u3099\u306e\u6027\u8cea\u306e\u9055\u3044\u306b\u3088\u308a\u30ab\u30e9\u30e0\u5185\u3092\u79fb\u52d5\u3059\u308b\u901f\u5ea6\u304b\u3099\u7570\u306a\u308b\u305f\u3081\u3001\u30ab\u30e9\u30e0\u3092\u901a\u904e\u3059\u308b\u9593\u306b\u30a4\u30aa\u30f3\u6210\u5206\u304b\u3099\u5206\u96e2\u3055\u308c\u3066\u3044\u304d\u307e\u3059<\/strong>\u3002\u56f35\u306b\u30ab\u30e9\u30e0\u5185\u3066\u3099\u306e\u5206\u96e2\u306e\u30a4\u30e1\u30fc\u30b7\u3099\u3092\u793a\u3057\u307e\u3059\u3002<\/p>\n<div id=\"attachment_1180\" style=\"width: 487px\" class=\"wp-caption aligncenter\"><a href=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/ion-chromatography-basic-fig5.png\" target=\"_blank\" rel=\"attachment noopener wp-att-1180\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-1180\" class=\"wp-image-1180 size-full\" src=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/ion-chromatography-basic-fig5.png\" alt=\"\u30ab\u30e9\u30e0\u5185\u3066\u3099\u306e\u5206\u96e2\u30a4\u30e1\u30fc\u30b7\u3099\" width=\"477\" height=\"526\" \/><\/a><p id=\"caption-attachment-1180\" class=\"wp-caption-text\">\u56f35 \u30ab\u30e9\u30e0\u5185\u3066\u3099\u306e\u5206\u96e2\u30a4\u30e1\u30fc\u30b7\u3099<\/p><\/div>\n<p>\u30ab\u30e9\u30e0\u304b\u3089\u6eb6\u51fa\u3057\u305f\u30a4\u30aa\u30f3\u6210\u5206\u3068\u6eb6\u96e2\u6db2\u306f\u30b5\u30d5\u309a\u30ec\u30c3\u30b5\u30fc\u306b\u5165\u308a\u307e\u3059\u3002<strong>\u30b5\u30d5\u309a\u30ec\u30c3\u30b5\u30fc\u306f\u6e2c\u5b9a\u30a4\u30aa\u30f3\u6210\u5206\u306e\u611f\u5ea6\u3092\u9ad8\u3081\u3001\u6eb6\u96e2\u6db2\u306e\u30cf\u3099\u30c3\u30af\u30af\u3099\u30e9\u30a6\u30f3\u30c8\u3099\u3092\u4f4e\u4e0b\u3055\u305b\u3066\u6e2c\u5b9a\u611f\u5ea6\u3092\u5411\u4e0a\u3055\u305b\u307e\u3059<\/strong>\u3002\u30a4\u30aa\u30f3\u6210\u5206\u306f\u30b5\u30d5\u309a\u30ec\u30c3\u30b5\u30fc\u3092\u901a\u904e\u3057\u305f\u5f8c\u3001\u691c\u51fa\u5668\u3066\u3099\u691c\u51fa\u3055\u308c\u307e\u3059\u3002<\/p>\n<p>\u30a4\u30aa\u30f3\u30af\u30ed\u30de\u30c8\u30af\u3099\u30e9\u30d5\u30a3\u30fc\u3066\u3099<strong>\u3082\u3063\u3068\u3082\u591a\u304f\u4f7f\u7528\u3055\u308c\u3066\u3044\u308b\u691c\u51fa\u5668\u306f\u96fb\u6c17\u4f1d\u5c0e\u5ea6\u691c\u51fa\u5668<\/strong>\u3066\u3099\u3059\u3002\u96fb\u6c17\u4f1d\u5c0e\u5ea6\u691c\u51fa\u5668\u3066\u3099\u306f\u3001\u691c\u51fa\u5668\u30bb\u30eb\u5185\u306e\u96fb\u6975\u9593\u3092\u901a\u904e\u3059\u308b\u6db2\u4e2d\u3066\u3099\u30a4\u30aa\u30f3\u5316\u3057\u3066\u3044\u308b\u6210\u5206\u306e\u307f\u3092\u691c\u51fa\u3057\u307e\u3059\u3002\u96fb\u6c17\u4f1d\u5c0e\u5ea6\u306f\u62b5\u6297\u306e\u9006\u6570\u3066\u3099\u3001\u5358\u4f4d\u306fS\/m\u3066\u3099\u8868\u3055\u308c\u307e\u3059\u3002\u96fb\u6c17\u4f1d\u5c0e\u5ea6\u306e\u30b7\u30af\u3099\u30ca\u30eb\u306e\u5f37\u3055\u306f\u6210\u5206\u306e\u7a2e\u985e\u3068\u305d\u306e\u89e3\u96e2\u72b6\u614b\u306b\u4f9d\u5b58\u3057\u307e\u3059\u3002<\/p>\n<p>\u96fb\u6c17\u4f1d\u5c0e\u5ea6\u691c\u51fa\u5668\u306f\u3001\u30a4\u30aa\u30f3\u6210\u5206\u306e\u307f\u3092\u691c\u51fa\u3059\u308b\u305f\u3081\u30a4\u30aa\u30f3\u5206\u6790\u306b\u306f\u975e\u5e38\u306b\u9069\u3057\u305f\u691c\u51fa\u5668\u3066\u3099\u3059\u304b\u3099\u3001\u6e2c\u5b9a\u76ee\u7684\u6210\u5206\u305f\u3099\u3051\u3066\u3099\u306a\u304f\u6eb6\u96e2\u6db2\u81ea\u4f53\u3082\u89e3\u96e2\u3057\u3066\u3044\u308b\u305f\u3081\u3001\u6eb6\u96e2\u6db2\u304b\u3099\u9ad8\u3044\u96fb\u6c17\u4f1d\u5c0e\u5ea6\u3092\u793a\u3057\u307e\u3059\u3002\u6eb6\u96e2\u6db2\u306e\u30cf\u3099\u30c3\u30af\u30af\u3099\u30e9\u30a6\u30f3\u30c8\u3099\u96fb\u6c17\u4f1d\u5c0e\u5ea6\u304b\u3099\u9ad8\u3044\u3068\u30ce\u30a4\u30b9\u3099\u304b\u3099\u9ad8\u304f\u306a\u308a\u3001\u9ad8\u611f\u5ea6\u5206\u6790\u304b\u3099\u96e3\u3057\u304f\u306a\u308a\u307e\u3059\u304b\u3099\u3001\u96fb\u6c17\u4f1d\u5c0e\u5ea6\u691c\u51fa\u5668\u306e\u524d\u306b\u30b5\u30d5\u309a\u30ec\u30c3\u30b5\u30fc\u3092\u53d6\u308a\u4ed8\u3051\u3066\u6eb6\u96e2\u6db2\u306e\u89e3\u96e2\u3092\u6291\u5236\u3059\u308b\u3053\u3068\u3066\u3099\u3001\u6eb6\u96e2\u6db2\u306e\u30cf\u3099\u30c3\u30af\u30af\u3099\u30e9\u30a6\u30f3\u30c8\u3099\u96fb\u6c17\u4f1d\u5c0e\u5ea6\u3092\u4f4e\u4e0b\u3055\u305b\u308b\u3053\u3068\u304b\u3099\u3066\u3099\u304d\u307e\u3059\u3002<\/p>\n<p>\u3053\u306e\u691c\u51fa\u5668\u3066\u3099\u691c\u51fa\u3055\u308c\u308b\u96fb\u6c17\u4f1d\u5c0e\u5ea6\u3068\u306f\u3001\u691c\u51fa\u5668\u306e\u30bb\u30eb\u3092\u901a\u904e\u3059\u308b\u6eb6\u6db2\u4e2d\u306e\u9670\u30a4\u30aa\u30f3\u3068\u967d\u30a4\u30aa\u30f3\u306e\u4f1d\u5c0e\u7387\u306e\u548c\u306a\u306e\u3066\u3099\u3001\u9670\u30a4\u30aa\u30f3\u3092\u6e2c\u5b9a\u3059\u308b\u5834\u5408\u3066\u3099\u3082\u3001\u305d\u306e\u5bfe\u3068\u306a\u308b\u967d\u30a4\u30aa\u30f3\u306e\u4f1d\u5c0e\u7387\u304b\u3099\u9ad8\u3051\u308c\u306f\u3099\u9670\u30a4\u30aa\u30f3\u306e\u6e2c\u5b9a\u611f\u5ea6\u304b\u3099\u4e0a\u304b\u3099\u308a\u307e\u3059\u3002\u88681\u306b\u30a4\u30aa\u30f3\u6210\u5206\u306e\u30e2\u30eb\u4f1d\u5c0e\u7387\u3092\u793a\u3057\u307e\u3059\u3002<\/p>\n<p>\u9670\u30a4\u30aa\u30f3\u5206\u6790\u306e\u5834\u5408\u306f\u3001\u30b5\u30d5\u309a\u30ec\u30c3\u30b5\u30fc\u5185\u3066\u3099\u300c\u967d\u30a4\u30aa\u30f3\u2192\u6c34\u7d20\u30a4\u30aa\u30f3\u300d\u306e\u4ea4\u63db\u304b\u3099\u8d77\u3053\u308a\u307e\u3059\u3002\u88681\u304b\u3089\u308f\u304b\u308b\u3088\u3046\u306b\u6c34\u7d20\u30a4\u30aa\u30f3\u306f\u4f1d\u5c0e\u7387\u304b\u3099\u9ad8\u3044\u305f\u3081\u3001\u6e2c\u5b9a\u76ee\u7684\u9670\u30a4\u30aa\u30f3\u6210\u5206\u306e\u5bfe\u30a4\u30aa\u30f3\u304b\u3099\u6c34\u7d20\u30a4\u30aa\u30f3\u306b\u306a\u308b\u3053\u3068\u3066\u3099\u9670\u30a4\u30aa\u30f3\u6210\u5206\u306e\u611f\u5ea6\u304b\u3099\u4e0a\u304b\u3099\u308a\u307e\u3059\u3002<\/p>\n<table>\n<caption>\u88681 \u30a4\u30aa\u30f3\u6210\u5206\u306e\u30e2\u30eb\u4f1d\u5c0e\u7387<\/caption>\n<tbody>\n<tr>\n<td>\u967d\u30a4\u30aa\u30f3<\/td>\n<td>\u03bb<sup>+<\/sup><\/td>\n<td>\u9670\u30a4\u30aa\u30f3<\/td>\n<td>\u03bb<sup>&#8211;<\/sup><\/td>\n<\/tr>\n<tr>\n<td>H<sup>+<\/sup><\/td>\n<td>350<\/td>\n<td>OH<sup>&#8211;<\/sup><\/td>\n<td>198<\/td>\n<\/tr>\n<tr>\n<td>NH<sub>4<\/sub><sup>+<\/sup><\/td>\n<td>39<\/td>\n<td>F<sup>&#8211;<\/sup><\/td>\n<td>55<\/td>\n<\/tr>\n<tr>\n<td>Na<sup>+<\/sup><\/td>\n<td>50<\/td>\n<td>Cl<sup>&#8211;<\/sup><\/td>\n<td>76<\/td>\n<\/tr>\n<tr>\n<td>K<sup>+<\/sup><\/td>\n<td>74<\/td>\n<td>Br<sup>&#8211;<\/sup><\/td>\n<td>78<\/td>\n<\/tr>\n<tr>\n<td>1\/2 Mg<sup>2+<\/sup><\/td>\n<td>53<\/td>\n<td>NO<sub>3<\/sub><sup>&#8211;<\/sup><\/td>\n<td>71<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>\u03bb: \u30e2\u30eb\u4f1d\u5c0e\u7387\u3001\u5358\u4f4d: Sm<sup>2<\/sup>mol<sup>-1<\/sup>\u3001\u7dcf\u96fb\u6c17\u4f1d\u5c0e\u5ea6: \u03a3(\u03bb<sup>+<\/sup>)+\u03a3(\u03bb<sup>&#8211;<\/sup>)<\/p>\n<h2>\u30a4\u30aa\u30f3\u30af\u30ed\u30de\u30c8\u30af\u3099\u30e9\u30d5\u30a3\u30fc\u306e\u4f7f\u7528\u4f8b<\/h2>\n<p>\u30a4\u30aa\u30f3\u30af\u30ed\u30de\u30c8\u30af\u3099\u30e9\u30d5\u30a3\u30fc\u306f\u3001<strong>\u74b0\u5883\u6e2c\u5b9a\u3001\u54c1\u8cea\u7ba1\u7406\u3001\u7814\u7a76\u958b\u767a\u306a\u3068\u3099\u591a\u5c90\u306b\u308f\u305f\u308b\u5206\u91ce\u3066\u3099\u4f7f\u7528\u3055\u308c\u3066\u3044\u307e\u3059\u3002JIS\u3084\u4e0a\u6c34\u8a66\u9a13\u65b9\u6cd5\u306a\u3068\u3099\u3001\u3055\u307e\u3055\u3099\u307e\u306a\u516c\u5b9a\u6cd5\u306b\u3082\u63a1\u7528\u3055\u308c\u3066\u3044\u307e\u3059<\/strong>\u3002<\/p>\n<p>\u4e0b\u8a18\u306b\u30a4\u30aa\u30f3\u30af\u30ed\u30de\u30c8\u30af\u3099\u30e9\u30d5\u30a3\u30fc\u6cd5\u304b\u3099\u63a1\u7528\u3055\u308c\u3066\u3044\u308b\u516c\u5b9a\u6cd5\u306e\u4e00\u90e8\u3068\u30a2\u30d5\u309a\u30ea\u30b1\u30fc\u30b7\u30e7\u30f3\u3092\u8a18\u8f09\u3044\u305f\u3057\u307e\u3059\u3002<\/p>\n<p>\u3010\u516c\u5b9a\u6cd5\u3011<br \/>\n\u65e5\u672c\u5de5\u696d\u898f\u683c(JIS)\u3001\u4e0a\u6c34\u8a66\u9a13\u65b9\u6cd5\u3001\u4e0b\u6c34\u8a66\u9a13\u65b9\u6cd5\u3001\u885b\u751f\u8a66\u9a13\u6cd5\u3001\u98df\u54c1\u6dfb\u52a0\u7269\u5206\u6790\u6cd5\u3001\u571f\u58cc\u6a19\u6e96\u5206\u6790\u30fb\u6e2c\u5b9a\u6cd5\u3001\u5869\u8a66\u9a13\u65b9\u6cd5\u3001\u5927\u6c17\u6c5a\u67d3\u7269\u8cea\u6e2c\u5b9a\u6cd5\u6307\u91dd\u306a\u3068\u3099<\/p>\n<p>\u3010\u30a2\u30d7\u30ea\u30b1\u30fc\u30b7\u30e7\u30f3\u4f8b\u3011<\/p>\n<ul>\n<li>\u6c34\u9053\u6c34\u4e2d\u306e\u9670\u30a4\u30aa\u30f3\u3001\u967d\u30a4\u30aa\u30f3<\/li>\n<li>\u6392\u30ab\u3099\u30b9\u4e2d\u306e NOx\u3001SOx<\/li>\n<li>\u96e8\u6c34\u4e2d\u306e\u9670\u30a4\u30aa\u30f3\u2028\u30fb\u8d85\u7d14\u6c34\u4e2d\u306e\u5fae\u91cf\u30a4\u30aa\u30f3<\/li>\n<li>\u5de5\u5834\u6392\u6c34\u4e2d\u306e\u30d5\u30c3\u5316\u7269\u30a4\u30aa\u30f3<\/li>\n<li>\u7121\u96fb\u89e3\u30cb\u30c3\u30b1\u30eb\u30e1\u30c3\u30ad\u6db2\u4e2d\u306e\u9670\u30a4\u30aa\u30f3\u3001\u6709\u6a5f\u9178<\/li>\n<li>\u5316\u5b66\u85ac\u54c1\u4e2d\u306e\u4e0d\u7d14\u7269\u30a4\u30aa\u30f3<\/li>\n<li>\u30cf\u3099\u30a4\u30aa\u71c3\u6599\u4e2d\u306e\u9670\u30a4\u30aa\u30f3\u3001\u6709\u6a5f\u9178<\/li>\n<li>\u98df\u54c1\u4e2d\u306e\u30db\u309a\u30ea\u308a\u3093\u9178<\/li>\n<li>\u767a\u96fb\u6240\u30d5\u309a\u30ed\u30bb\u30b9\u6c34\u4e2d\u306e\u30a2\u30df\u30f3<\/li>\n<\/ul>\n<h2>\u3010\u7121\u6599\u30c0\u30a6\u30f3\u30ed\u30fc\u30c9\u3011\u30a4\u30aa\u30f3\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc\u304a\u5f79\u7acb\u3061\u8cc7\u6599\uff08\u57fa\u790e\u7de8\uff09<\/h2>\n<p>\u30a4\u30aa\u30f3\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u3092\u4f7f\u3044\u59cb\u3081\u3088\u3046\u3068\u8003\u3048\u3066\u3044\u308b\u3001\u5206\u96e2\u306e\u539f\u7406\u3084\u5206\u6790\u6642\u306e\u30dd\u30a4\u30f3\u30c8\u3092\u898b\u76f4\u3057\u305f\u3044\u3001\u30bd\u30d5\u30c8\u30a6\u30a7\u30a2\u306e\u6a5f\u80fd\u3092\u4f7f\u3044\u3053\u306a\u3057\u305f\u3044\u3001\u5177\u4f53\u7684\u306a\u5206\u6790\u4e8b\u4f8b\u3092\u77e5\u308a\u305f\u3044\u306a\u3069\u3002\u696d\u52d9\u306b\u3059\u3050\u306b\u5f79\u7acb\u3064\u30ce\u30a6\u30cf\u30a6\u304c\u8a70\u307e\u3063\u305f\u8cc7\u6599\u3092\u305c\u3072\u3001\u3054\u6d3b\u7528\u304f\u3060\u3055\u3044\u3002<\/p>\n<p><a class=\"btn btn-red\" href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/industrial\/chromatography\/ion-chromatography-ic\/dl-doc-basic.html?ICID=cmd_ic_r04_jp_ion_chromatography_basic_Social_LAB\" target=\"_blank\" rel=\"noopener noreferrer\">\u7121\u6599\u30c0\u30a6\u30f3\u30ed\u30fc\u30c9\u306f\u3053\u3061\u3089<\/a><\/p>\n<h2>\u3010\u7121\u6599\u3011 e-learning \u30a4\u30aa\u30f3\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc\u57fa\u790e\u77e5\u8b58<\/h2>\n<p>\u30a4\u30aa\u30f3\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc\u306b\u3064\u3044\u3066\u3001\u3088\u308a\u6df1\u304f\u5b66\u3073\u305f\u3044\u65b9\u306f\u3001e-learning(\u30aa\u30f3\u30e9\u30a4\u30f3\u30bb\u30df\u30ca\u30fc)\u3092\u3054\u5229\u7528\u304f\u3060\u3055\u3044\u3002<\/p>\n<p>\u5206\u96e2\u3084\u691c\u51fa\u6cd5\u306a\u3069\u306e\u539f\u7406\u3092\u4e2d\u5fc3\u3068\u3057\u305f\u57fa\u790e\u306e\u89e3\u8aac\u3084\u3001\u5b9f\u969b\u306e\u5206\u6790\u6642\u306b\u6ce8\u610f\u3059\u308b\u30dd\u30a4\u30f3\u30c8\u307e\u3067\u3001\u696d\u52d9\u306b\u5f79\u7acb\u3064\u30d2\u30f3\u30c8\u304c\u5b66\u3079\u307e\u3059\u3002<\/p>\n<p><a class=\"btn btn-red\" href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/technical-resources\/e-learnings\/ic-dl.html?ICID=cmd_ic_r04_jp_ion_chromatography_basic_Social_LAB\" target=\"_blank\" rel=\"noopener noreferrer\">\u8996\u8074\u306e\u304a\u7533\u3057\u8fbc\u307f\u306f\u3053\u3061\u3089<\/a><\/p>\n<p>&nbsp;<\/p>\n<p>\u7814\u7a76\u7528\u306b\u306e\u307f\u4f7f\u7528\u3067\u304d\u307e\u3059\u3002\u8a3a\u65ad\u7528\u306b\u306f\u4f7f\u7528\u3044\u305f\u3060\u3051\u307e\u305b\u3093\u3002<\/p>\n","protected":false},"excerpt":{"rendered":"<p>\u30a4\u30aa\u30f3\u30af\u30ed\u30de\u30c8\u30af\u3099\u30e9\u30d5\u30a3\u30fc\u306f\u3001\u6db2\u4f53\u30af\u30ed\u30de\u30c8\u30af\u3099\u30e9\u30d5\u306e\u4e00\u7a2e\u3066\u3099\u3042\u308b\u30a4\u30aa\u30f3\u30af\u30ed\u30de\u30c8\u30af\u3099\u30e9\u30d5\u3092\u7528\u3044\u3066\u3001\u4e3b\u306b\u6eb6\u6db2\u4e2d\u306e\u30a4\u30aa\u30f3\u6027\u6210\u5206\u306e\u5b9a\u6027\u30fb\u5b9a\u91cf\u3092\u884c\u3046\u5206\u6790\u624b\u6cd5\u3066\u3099\u3059\u3002\u4eca\u56de\u306f\u3001\u3053\u308c\u307e\u3066\u3099\u30a4\u30aa\u30f3\u30af\u30ed\u30de\u30c8\u30af\u3099\u30e9\u30d5\u30a3\u30fc\u306b\u5168\u304f\u63a5\u3059\u308b\u6a5f\u4f1a\u304b\u3099\u306a\u304b\u3063\u305f\u65b9\u306b\u3082\u308f\u304b\u308a\u3084\u3059\u304f\u3001\u30a4\u30aa\u30f3\u30af\u30ed\u30de\u30c8\u30af\u3099\u30e9\u30d5\u30a3\u30fc\u306e\u57fa\u790e\u3092\u3053\u3099\u7d39\u4ecb\u3057\u307e\u3059\u3002<\/p>\n","protected":false},"author":988,"featured_media":2626,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_monsterinsights_skip_tracking":false,"_genesis_hide_title":false,"_genesis_hide_breadcrumbs":false,"_genesis_hide_singular_image":false,"_genesis_hide_footer_widgets":false,"_genesis_custom_body_class":"","_genesis_custom_post_class":"","_genesis_layout":"","_jetpack_newsletter_access":"","_jetpack_dont_email_post_to_subs":false,"_jetpack_newsletter_tier_id":0,"_jetpack_memberships_contains_paywalled_content":false,"_jetpack_hide_featured_image":false,"_jetpack_featured_image_duplicate_dismissed":0,"_jetpack_feature_clip_id":0,"_jetpack_memberships_contains_paid_content":false,"footnotes":"","jetpack_post_was_ever_published":false},"categories":[157],"tags":[52],"division":[],"class_list":["post-388","post","type-post","status-publish","format-standard","has-post-thumbnail","category-analysis","tag-ion-chromatography","entry"],"_selected_authors":"","_selected_reviewers":"","acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v28.9 (Yoast SEO v28.9) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>\u30a4\u30aa\u30f3\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc\uff08IC\uff09\u3068\u306f? IC\u306e\u57fa\u790e\u77e5\u8b58| Thermo Fisher Scientific - JP<\/title>\n<meta name=\"description\" content=\"\u6db2\u4f53\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u306e\u4e00\u7a2e\u3067\u3042\u308b\u30a4\u30aa\u30f3\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u3092\u7528\u3044\u3066\u3001\u6eb6\u6db2\u4e2d\u306e\u30a4\u30aa\u30f3\u6027\u6210\u5206\u306e\u5b9a\u6027\u30fb\u5b9a\u91cf\u3092\u884c\u3046\u5206\u6790\u624b\u6cd5\u300c\u30a4\u30aa\u30f3\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc\uff08IC\uff09\u300d\u306e\u7279\u2fa7\u3084\u6e2c\u5b9a\u53ef\u80fd\u306a\u6210\u5206\u3001\u5b9f\u969b\u306e\u4f7f\u7528\u4f8b\u306a\u3069\u3092\u308f\u304b\u308a\u3084\u3059\u304f\u8aac\u660e\u3057\u307e\u3059\u3002\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/ion-chromatography-basic\/\" \/>\n<meta property=\"og:locale\" content=\"ja_JP\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"\u521d\u5fc3\u8005\u5fc5\u898b\uff01\u30a4\u30aa\u30f3\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc\u306e\u57fa\u790e\u77e5\u8b58\" \/>\n<meta property=\"og:description\" content=\"\u6db2\u4f53\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u306e\u4e00\u7a2e\u3067\u3042\u308b\u30a4\u30aa\u30f3\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u3092\u7528\u3044\u3066\u3001\u6eb6\u6db2\u4e2d\u306e\u30a4\u30aa\u30f3\u6027\u6210\u5206\u306e\u5b9a\u6027\u30fb\u5b9a\u91cf\u3092\u884c\u3046\u5206\u6790\u624b\u6cd5\u300c\u30a4\u30aa\u30f3\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc\uff08IC\uff09\u300d\u306e\u7279\u2fa7\u3084\u6e2c\u5b9a\u53ef\u80fd\u306a\u6210\u5206\u3001\u5b9f\u969b\u306e\u4f7f\u7528\u4f8b\u306a\u3069\u3092\u308f\u304b\u308a\u3084\u3059\u304f\u8aac\u660e\u3057\u307e\u3059\u3002\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/ion-chromatography-basic\/\" \/>\n<meta property=\"og:site_name\" content=\"Learning at the Bench\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/ThermoFisherJapan\" \/>\n<meta property=\"article:published_time\" content=\"2016-05-18T00:00:00+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2025-03-12T08:04:40+00:00\" \/>\n<meta property=\"og:image\" content=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/ion-chromatography-basic-title.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"1200\" \/>\n\t<meta property=\"og:image:height\" content=\"630\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"LATB Staff\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:creator\" content=\"@ThermoFisherJP\" \/>\n<meta name=\"twitter:site\" content=\"@ThermoFisherJP\" \/>\n<meta name=\"twitter:label1\" content=\"\u57f7\u7b46\u8005\" \/>\n\t<meta name=\"twitter:data1\" content=\"LATB Staff\" \/>\n\t<meta name=\"twitter:label2\" content=\"\u63a8\u5b9a\u8aad\u307f\u53d6\u308a\u6642\u9593\" \/>\n\t<meta name=\"twitter:data2\" content=\"14\u5206\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/ion-chromatography-basic\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/ion-chromatography-basic\\\/\"},\"author\":{\"name\":\"LATB Staff\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#\\\/schema\\\/person\\\/201e6a5abb838fa34e8ff0174b015d36\"},\"headline\":\"\u521d\u5fc3\u8005\u5fc5\u898b\uff01\u30a4\u30aa\u30f3\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc\u306e\u57fa\u790e\u77e5\u8b58\",\"datePublished\":\"2016-05-18T00:00:00+00:00\",\"dateModified\":\"2025-03-12T08:04:40+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/ion-chromatography-basic\\\/\"},\"wordCount\":72,\"commentCount\":0,\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/ion-chromatography-basic\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2019\\\/07\\\/ion-chromatography-basic-title.jpg\",\"keywords\":[\"\u30a4\u30aa\u30f3\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc\"],\"articleSection\":[\"\u5206\u6790\u30fb\u6e2c\u5b9a\u95a2\u9023\"],\"inLanguage\":\"ja\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/ion-chromatography-basic\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/ion-chromatography-basic\\\/\",\"url\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/ion-chromatography-basic\\\/\",\"name\":\"\u30a4\u30aa\u30f3\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc\uff08IC\uff09\u3068\u306f? IC\u306e\u57fa\u790e\u77e5\u8b58| Thermo Fisher Scientific - JP\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/ion-chromatography-basic\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/ion-chromatography-basic\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2019\\\/07\\\/ion-chromatography-basic-title.jpg\",\"datePublished\":\"2016-05-18T00:00:00+00:00\",\"dateModified\":\"2025-03-12T08:04:40+00:00\",\"author\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#\\\/schema\\\/person\\\/201e6a5abb838fa34e8ff0174b015d36\"},\"description\":\"\u6db2\u4f53\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u306e\u4e00\u7a2e\u3067\u3042\u308b\u30a4\u30aa\u30f3\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u3092\u7528\u3044\u3066\u3001\u6eb6\u6db2\u4e2d\u306e\u30a4\u30aa\u30f3\u6027\u6210\u5206\u306e\u5b9a\u6027\u30fb\u5b9a\u91cf\u3092\u884c\u3046\u5206\u6790\u624b\u6cd5\u300c\u30a4\u30aa\u30f3\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc\uff08IC\uff09\u300d\u306e\u7279\u2fa7\u3084\u6e2c\u5b9a\u53ef\u80fd\u306a\u6210\u5206\u3001\u5b9f\u969b\u306e\u4f7f\u7528\u4f8b\u306a\u3069\u3092\u308f\u304b\u308a\u3084\u3059\u304f\u8aac\u660e\u3057\u307e\u3059\u3002\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/ion-chromatography-basic\\\/#breadcrumb\"},\"inLanguage\":\"ja\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/ion-chromatography-basic\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"ja\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/ion-chromatography-basic\\\/#primaryimage\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2019\\\/07\\\/ion-chromatography-basic-title.jpg\",\"contentUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2019\\\/07\\\/ion-chromatography-basic-title.jpg\",\"width\":1200,\"height\":630,\"caption\":\"ion-chromatography-basic-title\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/ion-chromatography-basic\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"\u521d\u5fc3\u8005\u5fc5\u898b\uff01\u30a4\u30aa\u30f3\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc\u306e\u57fa\u790e\u77e5\u8b58\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#website\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/\",\"name\":\"Learning at the Bench\",\"description\":\"\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"ja\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#\\\/schema\\\/person\\\/201e6a5abb838fa34e8ff0174b015d36\",\"name\":\"LATB Staff\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"ja\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/8803277856c8b753feb4217dff0f9953327452df1a615c3c88b2f9864efb2ddd?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/8803277856c8b753feb4217dff0f9953327452df1a615c3c88b2f9864efb2ddd?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/8803277856c8b753feb4217dff0f9953327452df1a615c3c88b2f9864efb2ddd?s=96&d=mm&r=g\",\"caption\":\"LATB Staff\"},\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/author\\\/latbstaff\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"\u30a4\u30aa\u30f3\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc\uff08IC\uff09\u3068\u306f? IC\u306e\u57fa\u790e\u77e5\u8b58| Thermo Fisher Scientific - JP","description":"\u6db2\u4f53\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u306e\u4e00\u7a2e\u3067\u3042\u308b\u30a4\u30aa\u30f3\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u3092\u7528\u3044\u3066\u3001\u6eb6\u6db2\u4e2d\u306e\u30a4\u30aa\u30f3\u6027\u6210\u5206\u306e\u5b9a\u6027\u30fb\u5b9a\u91cf\u3092\u884c\u3046\u5206\u6790\u624b\u6cd5\u300c\u30a4\u30aa\u30f3\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc\uff08IC\uff09\u300d\u306e\u7279\u2fa7\u3084\u6e2c\u5b9a\u53ef\u80fd\u306a\u6210\u5206\u3001\u5b9f\u969b\u306e\u4f7f\u7528\u4f8b\u306a\u3069\u3092\u308f\u304b\u308a\u3084\u3059\u304f\u8aac\u660e\u3057\u307e\u3059\u3002","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/ion-chromatography-basic\/","og_locale":"ja_JP","og_type":"article","og_title":"\u521d\u5fc3\u8005\u5fc5\u898b\uff01\u30a4\u30aa\u30f3\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc\u306e\u57fa\u790e\u77e5\u8b58","og_description":"\u6db2\u4f53\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u306e\u4e00\u7a2e\u3067\u3042\u308b\u30a4\u30aa\u30f3\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u3092\u7528\u3044\u3066\u3001\u6eb6\u6db2\u4e2d\u306e\u30a4\u30aa\u30f3\u6027\u6210\u5206\u306e\u5b9a\u6027\u30fb\u5b9a\u91cf\u3092\u884c\u3046\u5206\u6790\u624b\u6cd5\u300c\u30a4\u30aa\u30f3\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc\uff08IC\uff09\u300d\u306e\u7279\u2fa7\u3084\u6e2c\u5b9a\u53ef\u80fd\u306a\u6210\u5206\u3001\u5b9f\u969b\u306e\u4f7f\u7528\u4f8b\u306a\u3069\u3092\u308f\u304b\u308a\u3084\u3059\u304f\u8aac\u660e\u3057\u307e\u3059\u3002","og_url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/ion-chromatography-basic\/","og_site_name":"Learning at the Bench","article_publisher":"https:\/\/www.facebook.com\/ThermoFisherJapan","article_published_time":"2016-05-18T00:00:00+00:00","article_modified_time":"2025-03-12T08:04:40+00:00","og_image":[{"width":1200,"height":630,"url":"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/ion-chromatography-basic-title.jpg","type":"image\/jpeg"}],"author":"LATB Staff","twitter_card":"summary_large_image","twitter_creator":"@ThermoFisherJP","twitter_site":"@ThermoFisherJP","twitter_misc":{"\u57f7\u7b46\u8005":"LATB Staff","\u63a8\u5b9a\u8aad\u307f\u53d6\u308a\u6642\u9593":"14\u5206"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/ion-chromatography-basic\/#article","isPartOf":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/ion-chromatography-basic\/"},"author":{"name":"LATB Staff","@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#\/schema\/person\/201e6a5abb838fa34e8ff0174b015d36"},"headline":"\u521d\u5fc3\u8005\u5fc5\u898b\uff01\u30a4\u30aa\u30f3\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc\u306e\u57fa\u790e\u77e5\u8b58","datePublished":"2016-05-18T00:00:00+00:00","dateModified":"2025-03-12T08:04:40+00:00","mainEntityOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/ion-chromatography-basic\/"},"wordCount":72,"commentCount":0,"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/ion-chromatography-basic\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/ion-chromatography-basic-title.jpg","keywords":["\u30a4\u30aa\u30f3\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc"],"articleSection":["\u5206\u6790\u30fb\u6e2c\u5b9a\u95a2\u9023"],"inLanguage":"ja","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/ion-chromatography-basic\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/ion-chromatography-basic\/","url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/ion-chromatography-basic\/","name":"\u30a4\u30aa\u30f3\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc\uff08IC\uff09\u3068\u306f? IC\u306e\u57fa\u790e\u77e5\u8b58| Thermo Fisher Scientific - JP","isPartOf":{"@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/ion-chromatography-basic\/#primaryimage"},"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/ion-chromatography-basic\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/ion-chromatography-basic-title.jpg","datePublished":"2016-05-18T00:00:00+00:00","dateModified":"2025-03-12T08:04:40+00:00","author":{"@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#\/schema\/person\/201e6a5abb838fa34e8ff0174b015d36"},"description":"\u6db2\u4f53\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u306e\u4e00\u7a2e\u3067\u3042\u308b\u30a4\u30aa\u30f3\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u3092\u7528\u3044\u3066\u3001\u6eb6\u6db2\u4e2d\u306e\u30a4\u30aa\u30f3\u6027\u6210\u5206\u306e\u5b9a\u6027\u30fb\u5b9a\u91cf\u3092\u884c\u3046\u5206\u6790\u624b\u6cd5\u300c\u30a4\u30aa\u30f3\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc\uff08IC\uff09\u300d\u306e\u7279\u2fa7\u3084\u6e2c\u5b9a\u53ef\u80fd\u306a\u6210\u5206\u3001\u5b9f\u969b\u306e\u4f7f\u7528\u4f8b\u306a\u3069\u3092\u308f\u304b\u308a\u3084\u3059\u304f\u8aac\u660e\u3057\u307e\u3059\u3002","breadcrumb":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/ion-chromatography-basic\/#breadcrumb"},"inLanguage":"ja","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/ion-chromatography-basic\/"]}]},{"@type":"ImageObject","inLanguage":"ja","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/ion-chromatography-basic\/#primaryimage","url":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/ion-chromatography-basic-title.jpg","contentUrl":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/ion-chromatography-basic-title.jpg","width":1200,"height":630,"caption":"ion-chromatography-basic-title"},{"@type":"BreadcrumbList","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/ion-chromatography-basic\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/"},{"@type":"ListItem","position":2,"name":"\u521d\u5fc3\u8005\u5fc5\u898b\uff01\u30a4\u30aa\u30f3\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc\u306e\u57fa\u790e\u77e5\u8b58"}]},{"@type":"WebSite","@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#website","url":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/","name":"Learning at the Bench","description":"","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"ja"},{"@type":"Person","@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#\/schema\/person\/201e6a5abb838fa34e8ff0174b015d36","name":"LATB Staff","image":{"@type":"ImageObject","inLanguage":"ja","@id":"https:\/\/secure.gravatar.com\/avatar\/8803277856c8b753feb4217dff0f9953327452df1a615c3c88b2f9864efb2ddd?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/8803277856c8b753feb4217dff0f9953327452df1a615c3c88b2f9864efb2ddd?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/8803277856c8b753feb4217dff0f9953327452df1a615c3c88b2f9864efb2ddd?s=96&d=mm&r=g","caption":"LATB Staff"},"url":"https:\/\/admin.acceleratingscience.com\/author\/latbstaff\/"}]}},"taxonomy_info":{"category":[{"value":157,"label":"\u5206\u6790\u30fb\u6e2c\u5b9a\u95a2\u9023"}],"post_tag":[{"value":52,"label":"\u30a4\u30aa\u30f3\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc"}]},"featured_image_src_large":["https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/ion-chromatography-basic-title-1024x538.jpg",760,399,true],"author_info":{"display_name":"LATB Staff","author_link":"https:\/\/admin.acceleratingscience.com\/author\/latbstaff\/"},"comment_info":0,"category_info":[{"term_id":157,"name":"\u5206\u6790\u30fb\u6e2c\u5b9a\u95a2\u9023","slug":"analysis","term_group":0,"term_taxonomy_id":157,"taxonomy":"category","description":"","parent":0,"count":107,"filter":"raw","meta":[],"cat_ID":157,"category_count":107,"category_description":"","cat_name":"\u5206\u6790\u30fb\u6e2c\u5b9a\u95a2\u9023","category_nicename":"analysis","category_parent":0}],"tag_info":[{"term_id":52,"name":"\u30a4\u30aa\u30f3\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc","slug":"ion-chromatography","term_group":0,"term_taxonomy_id":52,"taxonomy":"post_tag","description":"","parent":0,"count":12,"filter":"raw","meta":[]}],"jetpack-related-posts":[{"id":25090,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/battery-development-elemental-analysis-csm-26016\/","url_meta":{"origin":388,"position":0},"title":"\u30ea\u30c1\u30a6\u30e0\u30a4\u30aa\u30f3\u96fb\u6c60\u88fd\u9020\uff1a\u4f7f\u7528\u3055\u308c\u308b\u5316\u5b66\u5206\u6790\u6280\u8853","author":"LatB Staff","date":"2026\u5e744\u670820\u65e5","format":false,"excerpt":"\u9ad8\u6027\u80fd\u96fb\u6c60\u306b\u5bfe\u3059\u308b\u9700\u8981\u306e\u6025\u5897\u306f\u3001\u751f\u7523\u306e\u3042\u3089\u3086\u308b\u6bb5\u968e\u306b\u304a\u3051\u308b\u5927\u898f\u6a21\u306a\u6295\u8cc7\u3092\u4fc3\u3057\u3066\u3044\u307e\u3059\u3002\u96fb\u6c60\u7814\u7a76\u304a\u3088\u3073\u2026","rel":"","context":"\u5206\u6790\u30fb\u6e2c\u5b9a\u95a2\u9023","block_context":{"text":"\u5206\u6790\u30fb\u6e2c\u5b9a\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/analysis\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/04\/battery-development-elemental-analysis-csm-26016_eyecatch.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/04\/battery-development-elemental-analysis-csm-26016_eyecatch.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/04\/battery-development-elemental-analysis-csm-26016_eyecatch.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/04\/battery-development-elemental-analysis-csm-26016_eyecatch.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/04\/battery-development-elemental-analysis-csm-26016_eyecatch.jpg?resize=1050%2C600&ssl=1 3x"},"classes":[]},{"id":25592,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/ion-chromatography-contaminant-analysis-cmd-26024\/","url_meta":{"origin":388,"position":1},"title":"\u5316\u7ca7\u54c1\u4e2d\u306ePFAS\u5206\u6790\u3068\u306f\uff1f\u7dcf\u6709\u6a5f\u30d5\u30c3\u7d20\uff08TOF\uff09\u6e2c\u5b9a\u306b\u3088\u308b\u30b9\u30af\u30ea\u30fc\u30cb\u30f3\u30b0\u3068\u898f\u5236\u5bfe\u5fdc","author":"LatB Staff","date":"2026\u5e749\u670810\u65e5","format":false,"excerpt":"PFAS\uff08\u6709\u6a5f\u30d5\u30c3\u7d20\u5316\u5408\u7269\uff09\u306f\u3001\u300c\u6c38\u9060\u306e\u5316\u5b66\u7269\u8cea\uff08Forever Chemicals\uff09\u300d\u3068\u3082\u547c\u3070\u308c\u3001\u2026","rel":"","context":"\u5206\u6790\u30fb\u6e2c\u5b9a\u95a2\u9023","block_context":{"text":"\u5206\u6790\u30fb\u6e2c\u5b9a\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/analysis\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/08\/ion-chromatography-contaminant-analysis-cmd-26024_eyecatch.png?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/08\/ion-chromatography-contaminant-analysis-cmd-26024_eyecatch.png?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/08\/ion-chromatography-contaminant-analysis-cmd-26024_eyecatch.png?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/08\/ion-chromatography-contaminant-analysis-cmd-26024_eyecatch.png?resize=700%2C400&ssl=1 2x"},"classes":[]},{"id":25362,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/battery-development-ion-chromatography-csm-26020\/","url_meta":{"origin":388,"position":2},"title":"IC-MS\/MS\u3092\u7528\u3044\u305f\u30ea\u30c1\u30a6\u30e0\u30a4\u30aa\u30f3\u96fb\u6c60\u8ca0\u6975\u306e\u52a3\u5316\u89e3\u6790","author":"LatB Staff","date":"2026\u5e746\u670826\u65e5","format":false,"excerpt":"\u539f\u6587\uff08\u82f1\u8a9e\uff09\uff1aExploring Lithium-Ion Battery Anode Degrada\u2026","rel":"","context":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","block_context":{"text":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/mol-bio\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/06\/battery-development-ion-chromatography-csm-26020_eyecatch.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/06\/battery-development-ion-chromatography-csm-26020_eyecatch.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/06\/battery-development-ion-chromatography-csm-26020_eyecatch.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/06\/battery-development-ion-chromatography-csm-26020_eyecatch.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/06\/battery-development-ion-chromatography-csm-26020_eyecatch.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/06\/battery-development-ion-chromatography-csm-26020_eyecatch.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":25673,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/ion-chromatography-semiconductors-cmd-26028\/","url_meta":{"origin":388,"position":3},"title":"\u534a\u5c0e\u4f53\u88fd\u9020\u306b\u304a\u3051\u308bIC\u306e\u5f79\u5272","author":"LatB Staff","date":"2026\u5e7410\u67082\u65e5","format":false,"excerpt":"\u30b9\u30de\u30fc\u30c8\u30d5\u30a9\u30f3\u3084AI\u30b5\u30fc\u30d0\u30fc\u3001\u81ea\u52d5\u8eca\u306a\u3069\u3001\u79c1\u305f\u3061\u306e\u8eab\u306e\u56de\u308a\u306b\u3042\u308b\u96fb\u5b50\u6a5f\u5668\u306e\u591a\u304f\u306f\u534a\u5c0e\u4f53\u306b\u3088\u3063\u3066\u652f\u3048\u3089\u2026","rel":"","context":"\u5206\u6790\u30fb\u6e2c\u5b9a\u95a2\u9023","block_context":{"text":"\u5206\u6790\u30fb\u6e2c\u5b9a\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/analysis\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/09\/ion-chromatography-semiconductors-cmd-26028_eyecatch.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/09\/ion-chromatography-semiconductors-cmd-26028_eyecatch.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/09\/ion-chromatography-semiconductors-cmd-26028_eyecatch.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/09\/ion-chromatography-semiconductors-cmd-26028_eyecatch.jpg?resize=700%2C400&ssl=1 2x"},"classes":[]},{"id":24614,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/battery-manufacturing-elemental-analysis-csm-26005\/","url_meta":{"origin":388,"position":4},"title":"\u96fb\u6c60\u30ea\u30b5\u30a4\u30af\u30eb\u306b\u304a\u3051\u308b\u5143\u7d20\u5206\u6790","author":"LatB Staff","date":"2026\u5e741\u670827\u65e5","format":false,"excerpt":"\u81ea\u52d5\u8eca\u306e\u96fb\u52d5\u5316\u3068\u518d\u751f\u53ef\u80fd\u30a8\u30cd\u30eb\u30ae\u30fc\u306e\u8caf\u8535\u80fd\u529b\u306e\u5897\u52a0\u306f\u3001\u3068\u3082\u306b\u96fb\u6c60\u306b\u5bfe\u3059\u308b\u9700\u8981\u306e\u5927\u5e45\u306a\u52a0\u901f\u3092\u3082\u305f\u3089\u3057\u3066\u2026","rel":"","context":"\u5206\u6790\u30fb\u6e2c\u5b9a\u95a2\u9023","block_context":{"text":"\u5206\u6790\u30fb\u6e2c\u5b9a\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/analysis\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/01\/battery-manufacturing-elemental-analysis-csm-26005_eyecatch.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/01\/battery-manufacturing-elemental-analysis-csm-26005_eyecatch.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/01\/battery-manufacturing-elemental-analysis-csm-26005_eyecatch.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/01\/battery-manufacturing-elemental-analysis-csm-26005_eyecatch.jpg?resize=700%2C400&ssl=1 2x"},"classes":[]},{"id":24695,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/environmental-analysis-laboratory-lpd-26008\/","url_meta":{"origin":388,"position":5},"title":"Orion Pro Star pH\uff0fISE\u30e1\u30fc\u30bf\u30fc\u3067\u5b9f\u73fe\u3059\u308b\u30a2\u30f3\u30e2\u30cb\u30a2\u30a4\u30aa\u30f3\u306e\u8fc5\u901f\u30fb\u9ad8\u7cbe\u5ea6\u6e2c\u5b9a\u5165\u9580","author":"LatB Staff","date":"2026\u5e742\u670818\u65e5","format":false,"excerpt":"\u6c34\u8cea\u30fb\u5ec3\u6c34\u51e6\u7406\u306e\u73fe\u5834\u3067\u306f\u3001\u30a2\u30f3\u30e2\u30cb\u30a2\u6fc3\u5ea6\u306e\u7ba1\u7406\u306f\u51e6\u7406\u30d7\u30ed\u30bb\u30b9\u3092\u6b63\u5e38\u306b\u4fdd\u3061\u3001\u6cd5\u898f\u5236\u306b\u9069\u5408\u3059\u308b\u305f\u3081\u306b\u6b20\u304b\u2026","rel":"","context":"\u5206\u6790\u30fb\u6e2c\u5b9a\u95a2\u9023","block_context":{"text":"\u5206\u6790\u30fb\u6e2c\u5b9a\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/analysis\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/01\/environmental-analysis-laboratory-lpd-26008_eyecatch_.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/01\/environmental-analysis-laboratory-lpd-26008_eyecatch_.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/01\/environmental-analysis-laboratory-lpd-26008_eyecatch_.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/01\/environmental-analysis-laboratory-lpd-26008_eyecatch_.jpg?resize=700%2C400&ssl=1 2x"},"classes":[]}],"jetpack_sharing_enabled":true,"amp_enabled":true,"jetpack_featured_media_url":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/ion-chromatography-basic-title.jpg","_links":{"self":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/posts\/388","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/users\/988"}],"replies":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/comments?post=388"}],"version-history":[{"count":0,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/posts\/388\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/media\/2626"}],"wp:attachment":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/media?parent=388"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/categories?post=388"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/tags?post=388"},{"taxonomy":"division","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/division?post=388"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}