{"id":398,"date":"2016-05-25T00:00:00","date_gmt":"2016-05-25T00:00:00","guid":{"rendered":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/viscoelasticity-basic1\/"},"modified":"2026-08-03T14:34:43","modified_gmt":"2026-08-03T05:34:43","slug":"viscoelasticity-basic1","status":"publish","type":"post","link":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/viscoelasticity-basic1\/","title":{"rendered":"\u521d\u5fc3\u8005\u5fc5\u898b\uff01\u7c98\u5f3e\u6027\u3068\u52d5\u7684\u7c98\u5f3e\u6027\u6e2c\u5b9a\u306e\u57fa\u790e"},"content":{"rendered":"\n<div class=\"wp-block-group is-nowrap is-layout-flex wp-container-core-group-is-layout-ad2f72ca wp-block-group-is-layout-flex\">\n<p>\u66f4\u65b0\u65e5 :<\/p>\n\n\n<div class=\"wp-block-post-date__modified-date wp-block-post-date\"><time datetime=\"2026-08-03T14:34:43+09:00\">8.3.2026<\/time><\/div><\/div>\n\n\n\n<div class=\"wp-block-tf-blocks-intro-summary\">\n<p>\u3053\u306e\u8a18\u4e8b\u306e\u8981\u70b9<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u7c98\u5f3e\u6027\u306f\u5f3e\u6027\u3068\u7c98\u6027\u304c\u8907\u5408\u3057\u3066\u751f\u3058\u308b\u6027\u8cea\u3067\u3042\u308a\u3001\u6750\u6599\u7279\u6027\u306f\u7c98\u5ea6\u3060\u3051\u3067\u306f\u8a55\u4fa1\u3067\u304d\u306a\u3044\u3002<\/li>\n\n\n\n<li>\u5f3e\u6027\u4f53\u306f\u30a8\u30cd\u30eb\u30ae\u30fc\u3092\u8caf\u8535\u3057\u3066\u5143\u306e\u72b6\u614b\u3078\u623b\u308a\u3001\u7c98\u6027\u4f53\u306f\u30a8\u30cd\u30eb\u30ae\u30fc\u3092\u6563\u9038\u3057\u3066\u5143\u306e\u72b6\u614b\u3078\u623b\u3089\u306a\u3044\u3002<\/li>\n\n\n\n<li>\u52d5\u7684\u7c98\u5f3e\u6027\u6e2c\u5b9a\u306f\u6b63\u5f26\u632f\u52d5\u3072\u305a\u307f\u306b\u5bfe\u3059\u308b\u5fdc\u529b\u5fdc\u7b54\u3092\u89e3\u6790\u3057\u3001\u8907\u7d20\u5f3e\u6027\u7387\uff08G*\uff09\u3068\u4f4d\u76f8\u89d2\uff08\u03b4\uff09\u3092\u7528\u3044\u3066\u7c98\u5f3e\u6027\u3092\u8a55\u4fa1\u3059\u308b\u624b\u6cd5\u3067\u3042\u308b\u3002<\/li>\n\n\n\n<li>\u8907\u7d20\u5f3e\u6027\u7387\uff08G*\uff09\u306f\u6750\u6599\u306e\u529b\u5b66\u7684\u306a\u786c\u3055\u3092\u3001\u4f4d\u76f8\u89d2\uff08\u03b4\uff09\u306f\u7c98\u6027\u4f53\u5bc4\u308a\u304b\u5f3e\u6027\u4f53\u5bc4\u308a\u304b\u3092\u793a\u3057\u3001\u4e21\u8005\u304b\u3089\u7c98\u5f3e\u6027\u3092\u7dcf\u5408\u8a55\u4fa1\u3067\u304d\u308b\u3002<\/li>\n<\/ul>\n<\/div>\n\n\n<style>.wp-block-kadence-spacer.kt-block-spacer-398_cd4947-82 .kt-block-spacer{height:20px;}.wp-block-kadence-spacer.kt-block-spacer-398_cd4947-82 .kt-divider{border-top-width:1px;height:1px;border-top-color:#000000;width:100%;border-top-style:solid;}<\/style>\n<div class=\"wp-block-kadence-spacer aligncenter kt-block-spacer-398_cd4947-82\"><div class=\"kt-block-spacer kt-block-spacer-halign-center\"><hr class=\"kt-divider\" \/><\/div><\/div>\n\n\n\n<p><strong><a href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/life-science\/lab-equipment\/rheometers-viscometers.html?CID=Social_LAB\" target=\"_blank\" rel=\"noopener noreferrer\">\u30ec\u30aa\u30e1\u30fc\u30bf\u30fc\uff08\u7c98\u5f3e\u6027\u6e2c\u5b9a\u88c5\u7f6e\uff09<\/a>\u306f\u3001\u5909\u5f62\u3068\u6d41\u52d5\u3092\u4f75\u305b\u6301\u3064\u7269\u4f53\u306e\u8907\u96d1\u306a\u6027\u8cea\u3092\u8abf\u3078\u3099\u308b\u3053\u3068\u304b\u3099\u3066\u3099\u304d\u307e\u3059<\/strong>\u304b\u3099\u3001\u7269\u6027\u5024\u306b\u8907\u7d20\u6570\u304b\u3099\u4f7f\u7528\u3055\u308c\u305f\u308a\u3001\u30cf\u309a\u30e9\u30e1\u30fc\u30bf\u30fc\u304b\u3099\u591a\u69d8\u3066\u3099\u3042\u3063\u305f\u308a\u3059\u308b\u305f\u3081\u3001\u6e2c\u5b9a\u539f\u7406\u304b\u3099\u8907\u96d1\u3066\u3099\u3042\u308b\u3068\u3044\u3046\u5370\u8c61\u3092\u6301\u305f\u308c\u308b\u304b\u3082\u3057\u308c\u307e\u305b\u3093\u3002\u30ec\u30aa\u30ed\u30b7\u3099\u30fc\u306e\u5165\u9580\u66f8\u3082\u3001\u5b9f\u969b\u306b\u30ec\u30aa\u30e1\u30fc\u30bf\u30fc\u3092\u64cd\u4f5c\u3059\u308b\u305f\u3081\u306e\u30d2\u30f3\u30c8\u3068\u306a\u308b\u3088\u3046\u306a\u5185\u5bb9\u3066\u3099\u306f\u306a\u304f\u3001\u5929\u4e0b\u308a\u7684\u306a\u8aac\u660e\u3068\u6570\u5f0f\u305f\u3099\u3089\u3051\u3066\u3099\u96e3\u3057\u3044\u3068\u3044\u3046\u58f0\u3082\u805e\u304b\u308c\u307e\u3059\u3002<\/p>\n\n\n\n<p><strong>\u4eca\u56de\u306f\u3001\u30ec\u30aa\u30e1\u30fc\u30bf\u30fc\u306e\u5165\u9580\u6a5f\u3068\u3057\u3066\u6700\u9069\u306a\u3001\u7c98\u5ea6\u8a08\u306e\u3088\u3046\u306b\u4f7f\u7528\u3066\u3099\u304d\u308b<a href=\"https:\/\/www.thermofisher.com\/order\/catalog\/product\/262-0001TS?CID=Social_LAB\" target=\"_blank\" rel=\"noopener noreferrer\">Thermo Scientic\u2122 HAAKE\u2122 Viscotester\u2122 iQ<\/a>\u3092\u7d39\u4ecb\u3057\u3064\u3064\u3001\u3053\u3099\u81ea\u8eab\u3066\u3099\u6d3b\u7528\u3066\u3099\u304d\u308b\u7a0b\u5ea6\u306b\u5fc5\u8981\u306a\u77e5\u8b58\u3092\u5f97\u3066\u3044\u305f\u305f\u3099\u304f\u3053\u3068\u3092\u76ee\u7684\u3068\u3057\u3066\u3001\u6e2c\u5b9a\u539f\u7406\u3068\u6e2c\u5b9a\u6761\u4ef6\u306e\u8a2d\u5b9a\u65b9\u6cd5\u30923\u90e8\u69cb\u6210\u3066\u3099\u89e3\u8aac\u3057\u307e\u3059\u3002<\/strong><\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-\u7c98\u5f3e\u6027\u306e\u57fa\u672c\u6982\u5ff5\">\u7c98\u5f3e\u6027\u306e\u57fa\u672c\u6982\u5ff5<\/h2>\n\n\n\n<p>\u6b6f\u78e8\u304d\u7c89\u306f\u6d41\u52d5\u3057\u30c1\u30e5\u30fc\u30d5\u3099\u304b\u3089\u62bc\u3057\u51fa\u3055\u308c\u307e\u3059\u304b\u3099\u3001\u6b6f\u30d5\u3099\u30e9\u30b7\u306e\u4e0a\u3066\u3099\u306f\u5782\u308c\u843d\u3061\u308b\u3053\u3068\u306a\u304f\u5f62\u72b6\u3092\u4fdd\u6301\u3057\u3001\u56fa\u4f53\u7684\u306b\u3075\u308b\u307e\u3044\u307e\u3059\u3002\u9006\u306b\u6c37\u306f\u529b\u3092\u52a0\u3048\u308c\u306f\u3099\u58ca\u308c\u3066\u3057\u307e\u3046\u56fa\u4f53\u3066\u3099\u3059\u304b\u3099\u3001\u6c37\u6cb3\u306f\u9577\u3044\u5e74\u6708\u3092\u304b\u3051\u3066\u5927\u304d\u304f\u5909\u5f62\u3057\u3001\u6db2\u4f53\u7684\u306b\u3075\u308b\u307e\u3044\u307e\u3059\u3002<\/p>\n\n\n\n<p>\u3053\u306e\u3088\u3046\u306b\u3001<strong>\u3068\u3099\u306e\u3088\u3046\u306a\u6750\u6599\u3082\u53b3\u5bc6\u306b\u306f\u56fa\u4f53\u3001\u6db2\u4f53\u306b\u5206\u985e\u3059\u308b\u3053\u3068\u306f\u3066\u3099\u304d\u3059\u3099\u3001\u5f3e\u6027\u4f53\u3068\u3057\u3066\u306e\u5909\u5f62\u6027\u3068\u6d41\u4f53\u3068\u3057\u3066\u306e\u6d41\u52d5\u6027\u3092\u4f75\u305b\u6301\u3063\u3066\u3044\u307e\u3059<\/strong>\u3002\u98df\u54c1\u3067\u4f8b\u3048\u308b\u3068\u3001\u51ac\u5834\u306e\u6c34\u3042\u3081\u3068\u30de\u30e8\u30cd\u30fc\u30b9\u3099\u306b\u6307\u3092\u62bc\u3057\u8fbc\u3093\u3066\u3099\u307f\u308b\u3068\u3001\u6c34\u3042\u3081\u306e\u65b9\u304b\u3099\u62bc\u3057\u3053\u307f\u306b\u304f\u3044\u3068\u611f\u3057\u3099\u307e\u3059\u3002\u3053\u308c\u306f\u3001\u6c34\u3042\u3081\u306e\u65b9\u304b\u3099\u9ad8\u7c98\u5ea6\u3066\u3099\u3042\u308b\u3053\u3068\u3092\u610f\u5473\u3057\u307e\u3059\u3002\u3068\u3053\u308d\u304b\u3099\u3001\u5272\u308a\u306f\u3099\u3057\u3066\u3099\u5f15\u304d\u4e0a\u3051\u3099\u305f\u6c34\u3042\u3081\u306f\u5782\u308c\u843d\u3061\u3066\u304d\u307e\u3059\u304b\u3099\u3001\u30de\u30e8\u30cd\u30fc\u30b9\u3099\u306f\u30c1\u30e5\u30fc\u30d5\u3099\u3092\u9006\u3055\u307e\u306b\u3057\u3066\u3082\u5782\u308c\u843d\u3061\u3066\u304d\u307e\u305b\u3093\u3002<strong>\u7269\u4f53\u306f\u7c98\u5ea6\u305f\u3099\u3051\u3066\u3099\u306f\u8a55\u4fa1\u304b\u3099\u3066\u3099\u304d\u3059\u3099\u3001\u7c98\u5f3e\u6027\u3092\u691c\u8a0e\u3057\u306a\u304f\u3066\u306f\u306a\u3089\u306a\u3044<\/strong>\u7406\u7531\u304b\u3099\u3053\u3053\u306b\u3042\u308a\u307e\u3059\u3002<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"h-\u5f3e\u6027\u3068\u306f\">\u5f3e\u6027\u3068\u306f\uff1f<\/h3>\n\n\n\n<p><strong>\u30d5\u30c3\u30af\u306e\u6cd5\u5247\u306b\u5f93\u3046\u7269\u4f53\u3092\u7406\u60f3\u5f3e\u6027\u4f53\u3068\u547c\u3072\u3099\u307e\u3059\u3002<\/strong>\u30d5\u30c3\u30af\u306e\u6cd5\u5247\u3068\u306f\u3001\u5358\u7d14\u306a\u30cf\u3099\u30cd\u6a21\u578b\u3092\u7528\u3044\u305f\u3068\u304d\u3001\u30cf\u3099\u30cd\u306e\u4f38\u3072\u3099\u3068\u964d\u4f0f\u5fdc\u529b\u4ee5\u4e0b\u306e\u8377\u91cd\u306b\u6bd4\u4f8b\u95a2\u4fc2\u304b\u3099\u6210\u7acb\u3059\u308b\u3068\u3044\u3046\u6cd5\u5247\u3066\u3099\u3059\u3002<\/p>\n\n\n\n<p><strong>\u7406\u60f3\u7684\u306a\u5f3e\u6027\u4f53\u3066\u3099\u306f\u3001\u529b\u3092\u52a0\u3048\u308b\u3068\u77ac\u6642\u306b\u4f38\u3072\u3099\u304b\u3099\u751f\u3057\u3099\u3001\u305d\u306e\u529b\u306b\u5fdc\u3057\u3099\u305f\u4f38\u3072\u3099\u3092\u7dad\u6301\u3057\u307e\u3059\u3002\u529b\u304b\u3099\u53d6\u308a\u9664\u304b\u308c\u308b\u3068\u3001\u5f3e\u6027\u30a8\u30cd\u30eb\u30ad\u3099\u30fc\u306b\u3088\u308a\u77ac\u6642\u306b\u5143\u306e\u72b6\u614b\u306b\u623b\u308a\u307e\u3059\u3002<\/strong><\/p>\n\n\n\n<figure class=\"wp-block-image aligncenter\"><a href=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/viscoelasticity-basic1-fig1.jpg\" rel=\"attachment wp-att-1200\"><img decoding=\"async\" src=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/viscoelasticity-basic1-fig1.jpg\" alt=\"viscoelasticity-basic1-fig1\" class=\"wp-image-1200\" \/><\/a><\/figure>\n\n\n\n<p><\/p>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"h-\u7c98\u6027\u3068\u306f\">\u7c98\u6027\u3068\u306f\uff1f<\/h3>\n\n\n\n<p>\u7c98\u6027\u3092\u8868\u3059\u306b\u306f\u3001\u30bf\u3099\u30c3\u30b7\u30e5\u30db\u309a\u30c3\u30c8(\u30d2\u309a\u30b9\u30c8\u30f3)\u6a21\u578b\u3092\u7528\u3044\u307e\u3059\u3002<strong>\u7406\u60f3\u7c98\u6027\u4f53\u304b\u3099\u5145\u586b\u3055\u308c\u305f\u30bf\u3099\u30c3\u30b7\u30e5\u30db\u309a\u30c3\u30c8\u306b\u529b\u3092\u52a0\u3048\u308b\u3068\u3001\u30d2\u309a\u30b9\u30c8\u30f3\u306e\u4f4d\u7f6e\u304b\u3099\u6642\u9593\u306b\u6bd4\u4f8b\u3057\u3066\u5909\u5316\u3057\u307e\u3059\u3002<\/strong>\u3053\u308c\u306f\u3001\u30d2\u309a\u30b9\u30c8\u30f3\u306e\u901f\u5ea6\u3068\u8377\u91cd\u306f\u6b63\u6bd4\u4f8b\u3059\u308b\u3068\u3044\u3046\u30cb\u30e5\u30fc\u30c8\u30f3\u306e\u7c98\u6027\u6cd5\u5247\u306b\u5f93\u3063\u3066\u3044\u308b\u305f\u3081\u3066\u3099\u3059\u3002<\/p>\n\n\n\n<p>\u5f3e\u6027\u4f53\u3068\u7570\u306a\u308a\u3001\u5909\u5f62\u306e\u305f\u3081\u306b\u52a0\u3048\u3089\u308c\u305f\u30a8\u30cd\u30eb\u30ad\u3099\u30fc\u306f\u5f3e\u6027\u30a8\u30cd\u30eb\u30ad\u3099\u30fc\u3068\u3057\u3066\u8caf\u8535\u3055\u308c\u3059\u3099\u3001\u6d41\u52d5\u6642\u306b\u5185\u90e8\u6469\u64e6\u306b\u3088\u308b\u71b1\u30a8\u30cd\u30eb\u30ad\u3099\u30fc\u3068\u3057\u3066\u6563\u9038\u3055\u308c\u307e\u3059\u3002\u305d\u306e\u305f\u3081\u3001<strong>\u529b\u304b\u3099\u53d6\u308a\u9664\u304b\u308c\u3066\u3082\u30d2\u309a\u30b9\u30c8\u30f3\u306e\u4f4d\u7f6e\u306f\u5143\u306b\u623b\u308a\u307e\u305b\u3093\u3002<\/strong><\/p>\n\n\n\n<figure class=\"wp-block-image aligncenter\"><a href=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/viscoelasticity-basic1-fig2.jpg\" rel=\"attachment wp-att-1201\"><img decoding=\"async\" src=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/viscoelasticity-basic1-fig2.jpg\" alt=\"viscoelasticity-basic1-fig2\" class=\"wp-image-1201\" \/><\/a><\/figure>\n\n\n\n<p><\/p>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"h-\u7c98\u5f3e\u6027\u3068\u306f\">\u7c98\u5f3e\u6027\u3068\u306f\uff1f<\/h3>\n\n\n\n<p><strong>\u7c98\u5f3e\u6027\u3068\u3044\u3046\u7269\u6027\u306f\u3001\u5358\u72ec\u3066\u3099\u306f\u5b58\u5728\u3057\u307e\u305b\u3093\u3002\u4f55\u3089\u304b\u306e\u7269\u4f53\u306e\u5909\u5f62\u3084\u6d41\u52d5\u3092\u8003\u3048\u308b\u969b\u3001\u305d\u308c\u306f\u5f3e\u6027\u3068\u7c98\u6027\u304b\u3099\u8907\u96d1\u306b\u7d61\u307f\u5408\u3063\u3066\u751f\u3057\u3099\u3066\u3044\u308b\u73fe\u8c61\u3066\u3099\u3042\u308b<\/strong>\u3068\u8003\u3048\u3089\u308c\u308b\u305f\u3081\u3066\u3099\u3059\u3002<\/p>\n\n\n\n<p><strong>\u7c98\u5f3e\u6027\u306f\u3001\u30d5\u30c3\u30af\u306e\u6cd5\u5247\u306b\u57fa\u3064\u3099\u304f\u5f3e\u6027\u7387\u3068\u3001\u7c98\u6027\u4f53\u306e\u6027\u8cea\u306b\u57fa\u3064\u3099\u304f\u6563\u9038\u3055\u308c\u308b\u30a8\u30cd\u30eb\u30ad\u3099\u30fc\u306e\u4e8c\u3064\u306e\u8981\u7d20\u306b\u8d77\u56e0\u3059\u308b\u6027\u8cea\u3066\u3099\u3042\u308b<\/strong>\u3068\u8a00\u3048\u307e\u3059\u3002\u305d\u306e\u305f\u3081\u3001\u7c98\u5f3e\u6027\u5024\u3092\u4e00\u3064\u306e\u6570\u76f4\u7dda\u4e0a\u306b\u8868\u3059\u3053\u3068\u306f\u3066\u3099\u304d\u307e\u305b\u3093\u3002\u865a\u6570\u8ef8\u3092\u7528\u3044\u3001\u8907\u7d20\u5e73\u9762\u4e0a\u3066\u3099\u306e\u539f\u70b9\u304b\u3089\u306e\u8ddd\u96e2\u3068\u305d\u306e\u504f\u89d2\u306e\u4e8c\u3064\u3066\u3099\u8868\u3057\u300cG* = G\u2019 + iG\u201d\u300d\u3068\u3044\u3046\u5f62\u3066\u3099\u3001\u4e00\u3064\u306e\u6570\u306b\u307e\u3068\u3081\u3066\u8868\u3057\u307e\u3059\u3002<br><\/p>\n\n\n\n<figure class=\"wp-block-image aligncenter\"><a href=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/viscoelasticity-basic1-fig3.jpg\" rel=\"attachment wp-att-1202\"><img decoding=\"async\" src=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/viscoelasticity-basic1-fig3.jpg\" alt=\"viscoelasticity-basic1-fig3\" class=\"wp-image-1202\" \/><\/a><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"h-\u5c0f\u307e\u3068\u3081-\u5f3e\u6027-\u7c98\u6027-\u7c98\u5f3e\u6027\u4f53\u306e\u9055\u3044\">\u5c0f\u307e\u3068\u3081\uff5e\u5f3e\u6027\u30fb\u7c98\u6027\u30fb\u7c98\u5f3e\u6027\u4f53\u306e\u9055\u3044\uff5e<\/h3>\n\n\n\n<p>\u2193\u3053\u3053\u307e\u3067\u306e\u30dd\u30a4\u30f3\u30c8\u3092\u307e\u3068\u3081\u305f\u306e\u304c\u4e0b\u8a18\u306e\u8868\u3067\u3059\u2193<\/p>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-9d6595d7 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:100%\">\n<figure class=\"wp-block-table\"><table><thead><tr><th class=\"has-text-align-center\" data-align=\"center\"><\/th><th class=\"has-text-align-center\" data-align=\"center\">\u5916\u529b\u3092\u53d6\u308a\u9664\u3044\u305f\u969b\u306b\u898b\u3089\u308c\u308b\u53cd\u5fdc<\/th><th class=\"has-text-align-center\" data-align=\"center\">\u5916\u529b\u3092\u4e0e\u3048\u305f\u969b\u306e\u30a8\u30cd\u30eb\u30ae\u30fc\u306e\u5909\u63db<\/th><\/tr><\/thead><tbody><tr><td class=\"has-text-align-center\" data-align=\"center\">\u5f3e\u6027\u4f53<\/td><td class=\"has-text-align-center\" data-align=\"center\">\u77ac\u6642\u306b\u5143\u306e\u72b6\u614b\u306b\u623b\u308b<\/td><td class=\"has-text-align-center\" data-align=\"center\">\u8caf\u8535\u3055\u308c\u308b<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">\u7c98\u6027\u4f53<\/td><td class=\"has-text-align-center\" data-align=\"center\">\u5143\u306e\u72b6\u614b\u306b\u623b\u3089\u306a\u3044<\/td><td class=\"has-text-align-center\" data-align=\"center\">\u640d\u5931\uff08\u6563\u9038\uff09\u3055\u308c\u308b<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">\u7c98\u5f3e\u6027\u4f53<\/td><td class=\"has-text-align-center\" data-align=\"center\">\u5f90\u3005\u306b\u5143\u306e\u72b6\u614b\u306b\u5411\u304b\u3046\uff08\u5b8c\u5168\u306b\u306f\u623b\u3089\u306a\u3044\uff09<\/td><td class=\"has-text-align-center\" data-align=\"center\">\u8caf\u8535\u5206\u3068\u640d\u5931\u5206\u306e\u7dcf\u548c<\/td><\/tr><\/tbody><\/table><\/figure>\n<\/div>\n<\/div>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-\u52d5\u7684\u7c98\u5f3e\u6027\u6e2c\u5b9a\u306e\u57fa\u672c\u6982\u5ff5\">\u52d5\u7684\u7c98\u5f3e\u6027\u6e2c\u5b9a\u306e\u57fa\u672c\u6982\u5ff5<\/h2>\n\n\n\n<p><strong>\u30ec\u30aa\u30e1\u30fc\u30bf\u30fc\u306e\u6b63\u5f26\u632f\u52d5\u3072\u305a\u307f\u306b\u3088\u308b\u5f3e\u6027\u7387\u306e\u6e2c\u5b9a\u3092\u52d5\u7684\u7c98\u6027\u6e2c\u5b9a\u3068\u547c\u3073\u307e\u3059\u3002<\/strong>\u3053\u3053\u3067\u3001\u8907\u7d20\u5e73\u9762\u3068\u52d5\u7684\u7c98\u5f3e\u6027\u6e2c\u5b9a\u304c\u3069\u306e\u3088\u3046\u306b\u7d50\u3073\u3064\u304f\u304b\u3092\u6982\u8aac\u3057\u307e\u3059\u3002<\/p>\n\n\n\n<p>\u8907\u7d20\u6570\u306f\u3001\u305f\u3068\u3048\u3070\u96fb\u6c17\u56de\u8def\u306a\u3069\u6ce2\u306e\u6027\u8cea\u3092\u6301\u3064\u73fe\u8c61\u3068\u76f8\u6027\u304c\u826f\u3044\u5834\u5408\u304c\u591a\u3044\u3067\u3059\u3002<strong>\u3082\u3063\u3068\u3082\u7c21\u5358\u306a\u5468\u671f\u7684\u632f\u52d5\u3067\u3042\u308b\u6b63\u5f26\u6ce2\u306b\u3088\u308b\u5fdc\u529b\u3092\u7269\u4f53\u306b\u52a0\u3048\u3001\u305d\u308c\u306b\u4f34\u3046\u5909\u5f62\u3092\u89b3\u5bdf\u3059\u308b\u304b\u3001\u9006\u306b\u5909\u5f62\u3092\u7269\u4f53\u306b\u52a0\u3048\u3001\u305d\u306e\u5fdc\u529b\u3092\u89b3\u5bdf\u3059\u308b\u3068\u3044\u3046\u52d5\u7684\u7c98\u5f3e\u6027\u6e2c\u5b9a\u624b\u6cd5\u306b\u3082\u5fdc\u7528\u3055\u308c\u307e\u3059\u3002<\/strong><\/p>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"h-\u52d5\u7684\u7c98\u5f3e\u6027\u6e2c\u5b9a\u624b\u6cd5\u306b\u3088\u308b\u5f3e\u6027\u4f53\u306e\u6e2c\u5b9a\">\u52d5\u7684\u7c98\u5f3e\u6027\u6e2c\u5b9a\u624b\u6cd5\u306b\u3088\u308b\u5f3e\u6027\u4f53\u306e\u6e2c\u5b9a<\/h3>\n\n\n\n<p><strong>\u5148\u307b\u3068\u3099\u306e\u30cf\u3099\u30cd\u6a21\u578b\u3092\u7528\u3044\u305f\u5f3e\u6027\u4f53\u3092\u52d5\u7684\u7c98\u5f3e\u6027\u6e2c\u5b9a\u624b\u6cd5\u306b\u3088\u308a\u6e2c\u5b9a\u3059\u308b\u5834\u5408\u3001\u5206\u9285\u306e\u91cd\u3055\u3001\u307e\u305f\u306f\u624b\u3066\u3099\u30cf\u3099\u30cd\u3092\u5f15\u3063\u5f35\u3063\u305f\u308a\u7e2e\u3081\u305f\u308a\u3068\u3044\u3046\u52d5\u4f5c\u3092\u3001\u6b63\u5f26\u5468\u671f\u7684\u306b\u5909\u5316\u3055\u305b\u308b\u3053\u3068\u304b\u3099\u8003\u3048\u3089\u308c\u307e\u3059\u3002<\/strong><\/p>\n\n\n\n<p>\u3072\u3059\u3099\u307f(\u4f38\u3072\u3099)\u3068\u5fdc\u529b(\u8377\u91cd)\u306e\u95a2\u4fc2\u306f\u4e0b\u306e\u30af\u3099\u30e9\u30d5\u306e\u901a\u308a\u3066\u3099\u3001\u4e21\u6ce2\u2028\u5f62\u306e\u632f\u308a\u5e45\u306e\u6bd4\u3092\u3068\u308c\u306f\u3099\u5f3e\u6027\u7387\u3068\u306a\u308a\u307e\u3059\u3002\u3088\u3063\u3066\u3001<strong>\u30d5\u30c3\u30af\u306e\u6cd5\u5247\u306e\u30cf\u3099\u30cd\u5b9f\u9a13\u3068\u672c\u8cea\u7684\u306b\u306f\u4f55\u3089\u5909\u308f\u3089\u306a\u3044\u3053\u3068\u304b\u3099\u5206\u304b\u308a\u307e\u3059\u3002<\/strong><br><\/p>\n\n\n\n<figure class=\"wp-block-image aligncenter\"><a href=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/viscoelasticity-basic1-fig4.jpg\" rel=\"attachment wp-att-1203\"><img decoding=\"async\" src=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/viscoelasticity-basic1-fig4.jpg\" alt=\"viscoelasticity-basic1-fig4\" class=\"wp-image-1203\" \/><\/a><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"h-\u52d5\u7684\u7c98\u5f3e\u6027\u6e2c\u5b9a\u624b\u6cd5\u306b\u3088\u308b\u7c98\u6027\u4f53\u306e\u6e2c\u5b9a\">\u52d5\u7684\u7c98\u5f3e\u6027\u6e2c\u5b9a\u624b\u6cd5\u306b\u3088\u308b\u7c98\u6027\u4f53\u306e\u6e2c\u5b9a<\/h3>\n\n\n\n<p>\u6b21\u306b\u3001\u5b8c\u5168\u7c98\u6027\u4f53\u3092\u30bf\u3099\u30c3\u30b7\u30e5\u30db\u309a\u30c3\u30c8\u6a21\u578b\u3092\u7528\u3044\u3066\u8aac\u660e\u3057\u307e\u3059\u3002<\/p>\n\n\n\n<p>\u4eca\u5ea6\u306f\u3001\u5206\u9285\u306e\u91cd\u3055\u3001\u307e\u305f\u306f\u624b\u3066\u3099\u30d2\u309a\u30b9\u30c8\u30f3\u3092\u5f15\u3063\u5f35\u3063\u305f\u308a\u7e2e\u3081\u305f\u308a\u3068\u3044\u3046\u52d5\u4f5c\u3092\u3001\u6b63\u5f26\u5468\u671f\u7684\u306b\u5909\u5316\u3055\u305b\u308b\u3053\u3068\u3092\u8003\u3048\u307e\u3059\u3002<strong>\u30d2\u309a\u30b9\u30c8\u30f3\u306e\u4f4d\u7f6e\u3068\u8377\u91cd\u306e\u95a2\u4fc2\u306f\u3001\u4e0b\u306e\u56f3\u306e\u901a\u308a\u3001\u4e8c\u3064\u306e\u6b63\u5f26\u6ce2\u5f62\u306e\u4f4d\u76f8\u306b90\u00b0\u306e\u5dee\u304b\u3099\u751f\u3057\u3099\u307e\u3059\u3002<\/strong><br><\/p>\n\n\n\n<figure class=\"wp-block-image aligncenter\"><a href=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/viscoelasticity-basic1-fig5.jpg\" rel=\"attachment wp-att-1204\"><img decoding=\"async\" src=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/viscoelasticity-basic1-fig5.jpg\" alt=\"viscoelasticity-basic1-fig5\" class=\"wp-image-1204\" \/><\/a><\/figure>\n\n\n\n<p>\u3053\u308c\u306f\u3001\u6b21\u306e\u56f3\u306e\u901a\u308a\u3001<strong>\u3072\u3059\u3099\u307f(\u4f4d\u7f6e)\u306e\u6700\u5927\u5024\u307e\u305f\u306f\u6700\u5c0f\u5024\u306e\u3068\u304d\u306b\u30d2\u309a\u30b9\u30c8\u30f3\u306e\u901f\u5ea6\u304b\u3099\u77ac\u9593\u7684\u306b0\u306b\u306a\u308a\u3001\u30d2\u309a\u30b9\u30c8\u30f3\u304b\u3099\u539f\u70b9\u4f4d\u7f6e\u3092\u901a\u308a\u904e\u304e\u308b\u3001\u3072\u305a\u307f0\u306e\u3068\u304d\u306b\u901f\u5ea6\u304c\u6700\u5927\u5024\u3068\u306a\u308a\u3001\u7c98\u6027\u4f53\u306f\u30cb\u30e5\u30fc\u30c8\u30f3\u306e\u7c98\u6027\u6cd5\u5247\u306b\u5f93\u3063\u3066\u3001\u5fdc\u529b\u3068\u901f\u5ea6\u304c\u6bd4\u4f8b\u95a2\u4fc2\u306b\u3042\u308b\u305f\u3081<\/strong>\u3067\u3059\u3002<br><\/p>\n\n\n\n<figure class=\"wp-block-image aligncenter\"><a href=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/viscoelasticity-basic1-fig6.jpg\" rel=\"attachment wp-att-1205\"><img decoding=\"async\" src=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/viscoelasticity-basic1-fig6.jpg\" alt=\"viscoelasticity-basic1-fig6\" class=\"wp-image-1205\" \/><\/a><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"h-\u7c98\u5f3e\u6027\u306e\u8a55\u4fa1\">\u7c98\u5f3e\u6027\u306e\u8a55\u4fa1<\/h3>\n\n\n\n<p><strong>\u7c98\u6027\u4f53\u306e\u5834\u5408\u3001\u4e0e\u3048\u3089\u308c\u305f\u3072\u305a\u307f\u30a8\u30cd\u30eb\u30ae\u30fc\u306f\u30d4\u30b9\u30c8\u30f3\u306e\u647a\u52d5\u4e2d\u306b\u6469\u64e6\u71b1\u3068\u3057\u3066\u6563\u9038\u3059\u308b\u305f\u3081\u901f\u5ea6\u306b\u5909\u308f\u308a\u300190\u00b0\u306e\u4f4d\u76f8\u5dee\u304c\u751f\u3058\u307e\u3059\u3002\u5f3e\u6027\u4f53\u306e\u5834\u5408\u306f\u5fdc\u529b\u3068\u3072\u305a\u307f\u91cf\u304c\u6bd4\u4f8b\u95a2\u4fc2\u306b\u3042\u308b\u305f\u3081\u3001\u4f4d\u76f8\u5dee\u304c\u751f\u3058\u307e\u305b\u3093\u3002<\/strong><\/p>\n\n\n\n<p>\u4e21\u6b63\u5f26\u6ce2\u306e\u632f\u308a\u5e45\u306e\u6bd4\u304b\u3099\u8907\u7d20\u5f3e\u6027\u7387[G*]\u306e\u5927\u304d\u3055\u3066\u3099\u3042\u308a\u3001\u3042\u308b\u7269\u4f53\u306e\u786c\u3055\u3092\u793a\u3057\u307e\u3059\u3002\u4f4d\u76f8\u5dee\u306f\u30a8\u30cd\u30eb\u30ad\u3099\u30fc\u640d\u5931\u3092\u8868\u3057\u3001\u8907\u7d20\u5e73\u9762\u4e0a\u3066\u3099\u504f\u89d2\u3068\u306a\u308a\u3001\u305d\u306e\u7269\u8cea\u304b\u3099\u7c98\u6027\u4f53(\u6db2\u72b6)\u5bc4\u308a\u306a\u306e\u304b\u5f3e\u6027\u4f53(\u56fa\u4f53\u72b6)\u5bc4\u308a\u306a\u306e\u304b\u3092\u793a\u3057\u307e\u3059\u3002<\/p>\n\n\n\n<p>\u4f4d\u76f8\u89d2\uff08\u03b4\uff09\u304c0\u00b0\u3067\u3042\u308c\u3070\u3001G\u2019=G*\u3067\u5b8c\u5168\u5f3e\u6027\u4f53\u300190\u00b0\u3067\u3042\u308c\u3070G\u2019\u2019=G*\u3067\u5b8c\u5168\u7c98\u6027\u4f53\u3001\u305d\u306e\u9593\u3092\u3068\u308b\u3082\u306e\u304c\u7c98\u5f3e\u6027\u4f53\u3067\u3042\u308b\u3068\u89e3\u91c8\u3067\u304d\u3001\u8907\u7d20\u5f3e\u6027\u304c\u793a\u3059\u786c\u3055\u60c5\u5831\u3068\u3068\u3082\u306b\u8907\u5408\u7684\u306b\u8a55\u4fa1\u3057\u307e\u3059\u3002<\/p>\n\n\n\n<p><strong>\u7c98\u5f3e\u6027\u306f\u3001\u3053\u306e\u3088\u3046\u306a\u60c5\u5831\u3092\u3082\u3068\u306b\u3001\u8907\u7d20\u5f3e\u6027\u3068\u3057\u3066\u300c\u3069\u306e\u3088\u3046\u306a\u300d\u7c98\u5f3e\u6027\u4f53\u306a\u306e\u304b\u304c\u8907\u7d20\u5e73\u9762\u4e0a\u306b\u8868\u3055\u308c\u308b\u3082\u306e\u3067\u3042\u308a\u3001\u5358\u7d14\u306b\u5024\u306e\u5927\u5c0f\u3092\u6c7a\u3081\u308b\u3053\u3068\u306f\u3067\u304d\u307e\u305b\u3093<\/strong>\uff08\u5b9f\u969b\u306e\u6e2c\u5b9a\u3067\u306f\u3001\u4e00\u822c\u7684\u306b\u5f3e\u6027\u7387\u3092\u4f4d\u76f8\u5dee\u306e\u5024\u3092\u8868\u793a\u3057\u307e\u3059\uff09\u3002<\/p>\n\n\n\n<p>\u4e0b\u56f3\u306f\u3001\u6c34\u3042\u3081\u3068\u30de\u30e8\u30cd\u30fc\u30ba\u3092\u8907\u7d20\u5e73\u9762\u4e0a\u3067\u8868\u3057\u305f\u30a4\u30e1\u30fc\u30b8\u3067\u3059\u3001\u307f\u306a\u3055\u3093\u304c\u6271\u308f\u308c\u308b\u6750\u6599\u306f\u3001\u5e73\u9762\u4e0a\u3069\u306e\u3088\u3046\u306a\u7c98\u5f3e\u6027\u3068\u3057\u3066\u8868\u3055\u308c\u308b\u3067\u3057\u3087\u3046\u304b\uff1f\u6b21\u56de\u306b\u7d9a\u304d\u307e\u3059\u3002<br><\/p>\n\n\n\n<figure class=\"wp-block-image aligncenter\"><a href=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/viscoelasticity-basic1-fig7.jpg\" rel=\"attachment wp-att-1206\"><img decoding=\"async\" src=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/viscoelasticity-basic1-fig7.jpg\" alt=\"viscoelasticity-basic1-fig7\" class=\"wp-image-1206\" \/><\/a><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-\u30ec\u30aa\u30e1\u30fc\u30bf\u30fc\u3084\u7c98\u5ea6\u8a08\u88fd\u54c1\u306b\u95a2\u3059\u308b\u304a\u554f\u3044\u5408\u308f\u305b\">\u30ec\u30aa\u30e1\u30fc\u30bf\u30fc\u3084\u7c98\u5ea6\u8a08\u88fd\u54c1\u306b\u95a2\u3059\u308b\u304a\u554f\u3044\u5408\u308f\u305b<\/h2>\n\n\n\n<p>\u3044\u304b\u304c\u3060\u3063\u305f\u3067\u3057\u3087\u3046\u304b\uff1f\u3000\u8a18\u4e8b\u3066\u3099\u30ab\u30cf\u3099\u30fc\u3066\u3099\u304d\u306a\u304b\u3063\u305f\u9ad8\u5ea6\u306a\u7528\u9014\u306b\u3064\u3044\u3066\u306f\u3001\u5f0a\u793e\u306e\u6280\u8853\u30c6\u30af\u30cb\u30ab\u30eb\u30b5\u30db\u309a\u30fc\u30c8\u307e\u3066\u3099\u3053\u3099\u76f8\u8ac7\u304f\u305f\u3099\u3055\u3044\uff08\u6700\u4e0b\u90e8\u30d5\u30a9\u30fc\u30e0\u53c2\u7167\uff09\u3002<\/p>\n\n\n\n<p>\u305d\u306e\u4ed6\u3001\u30ec\u30aa\u30e1\u30fc\u30bf\u30fc\u3084\u7c98\u5ea6\u8a08\u88fd\u54c1\u306b\u3064\u3044\u3066<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>\u30c7\u30e2<\/strong>\u3092\u4f9d\u983c\u3057\u305f\u3044<\/li>\n\n\n\n<li><strong>\u898b\u7a4d\u3082\u308a<\/strong>\u304c\u307b\u3057\u3044<\/li>\n\n\n\n<li>\u305d\u306e\u4ed6\uff08<strong>\u8cc7\u6599\u304c\u307b\u3057\u3044\u3001\u8a71\u3092\u805e\u3044\u3066\u307f\u305f\u3044\u3001\u62c5\u5f53\u8005\u304b\u3089\u9023\u7d61\u304c\u307b\u3057\u3044<\/strong> \u7b49\uff09<\/li>\n<\/ul>\n\n\n\n<p>\u7b49\u306e\u3054\u8981\u671b\u304c\u3042\u308a\u307e\u3057\u305f\u3089\u3001\u4e0b\u8a18\u30dc\u30bf\u30f3\u3088\u308a\u304a\u6c17\u8efd\u306b\u3054\u76f8\u8ac7\u304f\u3060\u3055\u3044\u3002<\/p>\n\n\n\n<p><a class=\"btn btn-red ext-link wpel-icon-right\" href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/life-science\/lab-equipment\/rheometers-viscometers\/rheometers-inquiry.html?CID=Social_LAB\" target=\"_blank\" rel=\"external noopener noreferrer\" data-wpel-link=\"external\">\u30ec\u30aa\u30e1\u30fc\u30bf\u30fc\u3084\u7c98\u5ea6\u8a08\u88fd\u54c1\u306b\u95a2\u3059\u308b\u304a\u554f\u3044\u5408\u308f\u305b\u306f\u3053\u3061\u3089<\/a><\/p>\n\n\n\n<p>&nbsp;<\/p>\n\n\n\n<p>&gt;&gt;\u52d5\u7684\u7c98\u5f3e\u6027\u6e2c\u5b9a\u306e\u5b9f\u6e2c\u4f8b\u3068\u30c7\u30fc\u30bf\u306e\u8aad\u307f\u65b9\u306f<a href=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/viscoelasticity-basic2\/?CID=Social_LAB\">\u3053\u3061\u3089<\/a><\/p>\n\n\n\n<p>&nbsp;<\/p>\n\n\n\n<p>\u7814\u7a76\u7528\u306b\u306e\u307f\u4f7f\u7528\u3067\u304d\u307e\u3059\u3002\u8a3a\u65ad\u7528\u306b\u306f\u4f7f\u7528\u3044\u305f\u3060\u3051\u307e\u305b\u3093\u3002<\/p>\n","protected":false},"excerpt":{"rendered":"<p>\u30ec\u30aa\u30e1\u30fc\u30bf\u30fc\u306f\u3001\u5909\u5f62\u3068\u6d41\u52d5\u3092\u4f75\u305b\u6301\u3064\u7269\u4f53\u306e\u8907\u96d1\u306a\u6027\u8cea\u3092\u8abf\u3078\u3099\u308b\u3053\u3068\u304b\u3099\u3066\u3099\u304d\u307e\u3059\u304b\u3099\u3001\u7269\u6027\u5024\u306b\u8907\u7d20\u6570\u304b\u3099\u4f7f\u7528\u3055\u308c\u305f\u308a\u3001\u30cf\u309a\u30e9\u30e1\u30fc\u30bf\u30fc\u304b\u3099\u591a\u69d8\u3066\u3099\u3042\u3063\u305f\u308a\u3059\u308b\u305f\u3081\u3001\u6e2c\u5b9a\u539f\u7406\u304b\u3099\u8907\u96d1\u3066\u3099\u3042\u308b\u3068\u3044\u3046\u5370\u8c61\u3092\u6301\u305f\u308c\u308b\u304b\u3082\u3057\u308c\u307e\u305b\u3093\u3002\u4eca\u56de\u306f\u3001\u7c98\u5f3e\u6027\u3068\u52d5\u7684\u7c98\u5f3e\u6027\u6e2c\u5b9a\u306e\u6e2c\u5b9a\u539f\u7406\u3092\u308f\u304b\u308a\u3084\u3059\u304f\u3054\u7d39\u4ecb\u3057\u307e\u3059\uff01<\/p>\n","protected":false},"author":988,"featured_media":2646,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_monsterinsights_skip_tracking":false,"_genesis_hide_title":false,"_genesis_hide_breadcrumbs":false,"_genesis_hide_singular_image":false,"_genesis_hide_footer_widgets":false,"_genesis_custom_body_class":"","_genesis_custom_post_class":"","_genesis_layout":"","_jetpack_newsletter_access":"","_jetpack_dont_email_post_to_subs":false,"_jetpack_newsletter_tier_id":0,"_jetpack_memberships_contains_paywalled_content":false,"_jetpack_feature_clip_id":0,"_jetpack_memberships_contains_paid_content":false,"footnotes":"","jetpack_post_was_ever_published":false},"categories":[157],"tags":[54],"division":[],"class_list":{"0":"post-398","1":"post","2":"type-post","3":"status-publish","4":"format-standard","5":"has-post-thumbnail","7":"category-analysis","8":"tag-dma","9":"entry"},"_selected_authors":[],"_selected_reviewers":[],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v27.8 (Yoast SEO v27.8) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>\u521d\u5fc3\u8005\u5fc5\u898b\uff01\u7c98\u5f3e\u6027\u3068\u52d5\u7684\u7c98\u5f3e\u6027\u6e2c\u5b9a\u306e\u57fa\u790e - Learning at the Bench<\/title>\n<meta name=\"description\" content=\"\u7c98\u5f3e\u6027\u3068\u52d5\u7684\u7c98\u5f3e\u6027\u6e2c\u5b9a\u306e\u57fa\u790e\u3092\u89e3\u8aac\u3057\u3001\u5f3e\u6027\u30fb\u7c98\u6027\u3068\u306e\u9055\u3044\u3001\u30ec\u30aa\u30e1\u30fc\u30bf\u30fc\u306b\u3088\u308b\u6e2c\u5b9a\u539f\u7406\u3001\u8907\u7d20\u5f3e\u6027\u7387\uff08G*\uff09\u3084\u4f4d\u76f8\u89d2\uff08\u03b4\uff09\u304c\u793a\u3059\u7269\u6027\u8a55\u4fa1\u306e\u8003\u3048\u65b9\u3092\u7d39\u4ecb\u3057\u307e\u3059\u3002\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/viscoelasticity-basic1\/\" \/>\n<meta property=\"og:locale\" content=\"ja_JP\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"\u521d\u5fc3\u8005\u5fc5\u898b\uff01\u7c98\u5f3e\u6027\u3068\u52d5\u7684\u7c98\u5f3e\u6027\u6e2c\u5b9a\u306e\u57fa\u790e\" \/>\n<meta property=\"og:description\" content=\"\u7c98\u5f3e\u6027\u3068\u52d5\u7684\u7c98\u5f3e\u6027\u6e2c\u5b9a\u306e\u57fa\u790e\u3092\u89e3\u8aac\u3057\u3001\u5f3e\u6027\u30fb\u7c98\u6027\u3068\u306e\u9055\u3044\u3001\u30ec\u30aa\u30e1\u30fc\u30bf\u30fc\u306b\u3088\u308b\u6e2c\u5b9a\u539f\u7406\u3001\u8907\u7d20\u5f3e\u6027\u7387\uff08G*\uff09\u3084\u4f4d\u76f8\u89d2\uff08\u03b4\uff09\u304c\u793a\u3059\u7269\u6027\u8a55\u4fa1\u306e\u8003\u3048\u65b9\u3092\u7d39\u4ecb\u3057\u307e\u3059\u3002\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/viscoelasticity-basic1\/\" \/>\n<meta property=\"og:site_name\" content=\"Learning at the Bench\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/ThermoFisherJapan\" \/>\n<meta property=\"article:published_time\" content=\"2016-05-25T00:00:00+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2026-08-03T05:34:43+00:00\" \/>\n<meta property=\"og:image\" content=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/viscoelasticity-basic-title.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"1200\" \/>\n\t<meta property=\"og:image:height\" content=\"630\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"LATB Staff\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:creator\" content=\"@ThermoFisherJP\" \/>\n<meta name=\"twitter:site\" content=\"@ThermoFisherJP\" \/>\n<meta name=\"twitter:label1\" content=\"\u57f7\u7b46\u8005\" \/>\n\t<meta name=\"twitter:data1\" content=\"LATB Staff\" \/>\n\t<meta name=\"twitter:label2\" content=\"\u63a8\u5b9a\u8aad\u307f\u53d6\u308a\u6642\u9593\" \/>\n\t<meta name=\"twitter:data2\" content=\"10\u5206\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/viscoelasticity-basic1\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/viscoelasticity-basic1\\\/\"},\"author\":{\"name\":\"LATB Staff\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#\\\/schema\\\/person\\\/00a095a01d54afcdf9457465feb04f7d\"},\"headline\":\"\u521d\u5fc3\u8005\u5fc5\u898b\uff01\u7c98\u5f3e\u6027\u3068\u52d5\u7684\u7c98\u5f3e\u6027\u6e2c\u5b9a\u306e\u57fa\u790e\",\"datePublished\":\"2016-05-25T00:00:00+00:00\",\"dateModified\":\"2026-08-03T05:34:43+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/viscoelasticity-basic1\\\/\"},\"wordCount\":19,\"commentCount\":0,\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/viscoelasticity-basic1\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2019\\\/07\\\/viscoelasticity-basic-title.jpg\",\"keywords\":[\"\u52d5\u7684\u7c98\u5f3e\u6027\u6e2c\u5b9a\"],\"articleSection\":[\"\u5206\u6790\u30fb\u6e2c\u5b9a\u95a2\u9023\"],\"inLanguage\":\"ja\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/viscoelasticity-basic1\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/viscoelasticity-basic1\\\/\",\"url\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/viscoelasticity-basic1\\\/\",\"name\":\"\u521d\u5fc3\u8005\u5fc5\u898b\uff01\u7c98\u5f3e\u6027\u3068\u52d5\u7684\u7c98\u5f3e\u6027\u6e2c\u5b9a\u306e\u57fa\u790e - Learning at the Bench\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/viscoelasticity-basic1\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/viscoelasticity-basic1\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2019\\\/07\\\/viscoelasticity-basic-title.jpg\",\"datePublished\":\"2016-05-25T00:00:00+00:00\",\"dateModified\":\"2026-08-03T05:34:43+00:00\",\"author\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#\\\/schema\\\/person\\\/00a095a01d54afcdf9457465feb04f7d\"},\"description\":\"\u7c98\u5f3e\u6027\u3068\u52d5\u7684\u7c98\u5f3e\u6027\u6e2c\u5b9a\u306e\u57fa\u790e\u3092\u89e3\u8aac\u3057\u3001\u5f3e\u6027\u30fb\u7c98\u6027\u3068\u306e\u9055\u3044\u3001\u30ec\u30aa\u30e1\u30fc\u30bf\u30fc\u306b\u3088\u308b\u6e2c\u5b9a\u539f\u7406\u3001\u8907\u7d20\u5f3e\u6027\u7387\uff08G*\uff09\u3084\u4f4d\u76f8\u89d2\uff08\u03b4\uff09\u304c\u793a\u3059\u7269\u6027\u8a55\u4fa1\u306e\u8003\u3048\u65b9\u3092\u7d39\u4ecb\u3057\u307e\u3059\u3002\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/viscoelasticity-basic1\\\/#breadcrumb\"},\"inLanguage\":\"ja\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/viscoelasticity-basic1\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"ja\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/viscoelasticity-basic1\\\/#primaryimage\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2019\\\/07\\\/viscoelasticity-basic-title.jpg\",\"contentUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2019\\\/07\\\/viscoelasticity-basic-title.jpg\",\"width\":1200,\"height\":630,\"caption\":\"viscoelasticity-basic-title\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/viscoelasticity-basic1\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"\u521d\u5fc3\u8005\u5fc5\u898b\uff01\u7c98\u5f3e\u6027\u3068\u52d5\u7684\u7c98\u5f3e\u6027\u6e2c\u5b9a\u306e\u57fa\u790e\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#website\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/\",\"name\":\"Learning at the Bench\",\"description\":\"\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"ja\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#\\\/schema\\\/person\\\/00a095a01d54afcdf9457465feb04f7d\",\"name\":\"LATB Staff\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"ja\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/8803277856c8b753feb4217dff0f9953327452df1a615c3c88b2f9864efb2ddd?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/8803277856c8b753feb4217dff0f9953327452df1a615c3c88b2f9864efb2ddd?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/8803277856c8b753feb4217dff0f9953327452df1a615c3c88b2f9864efb2ddd?s=96&d=mm&r=g\",\"caption\":\"LATB Staff\"},\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/author\\\/latbstaff\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"\u521d\u5fc3\u8005\u5fc5\u898b\uff01\u7c98\u5f3e\u6027\u3068\u52d5\u7684\u7c98\u5f3e\u6027\u6e2c\u5b9a\u306e\u57fa\u790e - Learning at the Bench","description":"\u7c98\u5f3e\u6027\u3068\u52d5\u7684\u7c98\u5f3e\u6027\u6e2c\u5b9a\u306e\u57fa\u790e\u3092\u89e3\u8aac\u3057\u3001\u5f3e\u6027\u30fb\u7c98\u6027\u3068\u306e\u9055\u3044\u3001\u30ec\u30aa\u30e1\u30fc\u30bf\u30fc\u306b\u3088\u308b\u6e2c\u5b9a\u539f\u7406\u3001\u8907\u7d20\u5f3e\u6027\u7387\uff08G*\uff09\u3084\u4f4d\u76f8\u89d2\uff08\u03b4\uff09\u304c\u793a\u3059\u7269\u6027\u8a55\u4fa1\u306e\u8003\u3048\u65b9\u3092\u7d39\u4ecb\u3057\u307e\u3059\u3002","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/viscoelasticity-basic1\/","og_locale":"ja_JP","og_type":"article","og_title":"\u521d\u5fc3\u8005\u5fc5\u898b\uff01\u7c98\u5f3e\u6027\u3068\u52d5\u7684\u7c98\u5f3e\u6027\u6e2c\u5b9a\u306e\u57fa\u790e","og_description":"\u7c98\u5f3e\u6027\u3068\u52d5\u7684\u7c98\u5f3e\u6027\u6e2c\u5b9a\u306e\u57fa\u790e\u3092\u89e3\u8aac\u3057\u3001\u5f3e\u6027\u30fb\u7c98\u6027\u3068\u306e\u9055\u3044\u3001\u30ec\u30aa\u30e1\u30fc\u30bf\u30fc\u306b\u3088\u308b\u6e2c\u5b9a\u539f\u7406\u3001\u8907\u7d20\u5f3e\u6027\u7387\uff08G*\uff09\u3084\u4f4d\u76f8\u89d2\uff08\u03b4\uff09\u304c\u793a\u3059\u7269\u6027\u8a55\u4fa1\u306e\u8003\u3048\u65b9\u3092\u7d39\u4ecb\u3057\u307e\u3059\u3002","og_url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/viscoelasticity-basic1\/","og_site_name":"Learning at the Bench","article_publisher":"https:\/\/www.facebook.com\/ThermoFisherJapan","article_published_time":"2016-05-25T00:00:00+00:00","article_modified_time":"2026-08-03T05:34:43+00:00","og_image":[{"width":1200,"height":630,"url":"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/viscoelasticity-basic-title.jpg","type":"image\/jpeg"}],"author":"LATB Staff","twitter_card":"summary_large_image","twitter_creator":"@ThermoFisherJP","twitter_site":"@ThermoFisherJP","twitter_misc":{"\u57f7\u7b46\u8005":"LATB Staff","\u63a8\u5b9a\u8aad\u307f\u53d6\u308a\u6642\u9593":"10\u5206"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/viscoelasticity-basic1\/#article","isPartOf":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/viscoelasticity-basic1\/"},"author":{"name":"LATB Staff","@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#\/schema\/person\/00a095a01d54afcdf9457465feb04f7d"},"headline":"\u521d\u5fc3\u8005\u5fc5\u898b\uff01\u7c98\u5f3e\u6027\u3068\u52d5\u7684\u7c98\u5f3e\u6027\u6e2c\u5b9a\u306e\u57fa\u790e","datePublished":"2016-05-25T00:00:00+00:00","dateModified":"2026-08-03T05:34:43+00:00","mainEntityOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/viscoelasticity-basic1\/"},"wordCount":19,"commentCount":0,"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/viscoelasticity-basic1\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/viscoelasticity-basic-title.jpg","keywords":["\u52d5\u7684\u7c98\u5f3e\u6027\u6e2c\u5b9a"],"articleSection":["\u5206\u6790\u30fb\u6e2c\u5b9a\u95a2\u9023"],"inLanguage":"ja","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/viscoelasticity-basic1\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/viscoelasticity-basic1\/","url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/viscoelasticity-basic1\/","name":"\u521d\u5fc3\u8005\u5fc5\u898b\uff01\u7c98\u5f3e\u6027\u3068\u52d5\u7684\u7c98\u5f3e\u6027\u6e2c\u5b9a\u306e\u57fa\u790e - Learning at the Bench","isPartOf":{"@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/viscoelasticity-basic1\/#primaryimage"},"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/viscoelasticity-basic1\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/viscoelasticity-basic-title.jpg","datePublished":"2016-05-25T00:00:00+00:00","dateModified":"2026-08-03T05:34:43+00:00","author":{"@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#\/schema\/person\/00a095a01d54afcdf9457465feb04f7d"},"description":"\u7c98\u5f3e\u6027\u3068\u52d5\u7684\u7c98\u5f3e\u6027\u6e2c\u5b9a\u306e\u57fa\u790e\u3092\u89e3\u8aac\u3057\u3001\u5f3e\u6027\u30fb\u7c98\u6027\u3068\u306e\u9055\u3044\u3001\u30ec\u30aa\u30e1\u30fc\u30bf\u30fc\u306b\u3088\u308b\u6e2c\u5b9a\u539f\u7406\u3001\u8907\u7d20\u5f3e\u6027\u7387\uff08G*\uff09\u3084\u4f4d\u76f8\u89d2\uff08\u03b4\uff09\u304c\u793a\u3059\u7269\u6027\u8a55\u4fa1\u306e\u8003\u3048\u65b9\u3092\u7d39\u4ecb\u3057\u307e\u3059\u3002","breadcrumb":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/viscoelasticity-basic1\/#breadcrumb"},"inLanguage":"ja","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/viscoelasticity-basic1\/"]}]},{"@type":"ImageObject","inLanguage":"ja","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/viscoelasticity-basic1\/#primaryimage","url":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/viscoelasticity-basic-title.jpg","contentUrl":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/viscoelasticity-basic-title.jpg","width":1200,"height":630,"caption":"viscoelasticity-basic-title"},{"@type":"BreadcrumbList","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/viscoelasticity-basic1\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/"},{"@type":"ListItem","position":2,"name":"\u521d\u5fc3\u8005\u5fc5\u898b\uff01\u7c98\u5f3e\u6027\u3068\u52d5\u7684\u7c98\u5f3e\u6027\u6e2c\u5b9a\u306e\u57fa\u790e"}]},{"@type":"WebSite","@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#website","url":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/","name":"Learning at the Bench","description":"","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"ja"},{"@type":"Person","@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#\/schema\/person\/00a095a01d54afcdf9457465feb04f7d","name":"LATB Staff","image":{"@type":"ImageObject","inLanguage":"ja","@id":"https:\/\/secure.gravatar.com\/avatar\/8803277856c8b753feb4217dff0f9953327452df1a615c3c88b2f9864efb2ddd?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/8803277856c8b753feb4217dff0f9953327452df1a615c3c88b2f9864efb2ddd?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/8803277856c8b753feb4217dff0f9953327452df1a615c3c88b2f9864efb2ddd?s=96&d=mm&r=g","caption":"LATB Staff"},"url":"https:\/\/admin.acceleratingscience.com\/author\/latbstaff\/"}]}},"taxonomy_info":{"category":[{"value":157,"label":"\u5206\u6790\u30fb\u6e2c\u5b9a\u95a2\u9023"}],"post_tag":[{"value":54,"label":"\u52d5\u7684\u7c98\u5f3e\u6027\u6e2c\u5b9a"}]},"featured_image_src_large":["https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/viscoelasticity-basic-title-1024x538.jpg",760,399,true],"author_info":{"display_name":"LATB Staff","author_link":"https:\/\/admin.acceleratingscience.com\/author\/latbstaff\/"},"comment_info":0,"category_info":[{"term_id":157,"name":"\u5206\u6790\u30fb\u6e2c\u5b9a\u95a2\u9023","slug":"analysis","term_group":0,"term_taxonomy_id":157,"taxonomy":"category","description":"","parent":0,"count":106,"filter":"raw","meta":[],"cat_ID":157,"category_count":106,"category_description":"","cat_name":"\u5206\u6790\u30fb\u6e2c\u5b9a\u95a2\u9023","category_nicename":"analysis","category_parent":0}],"tag_info":[{"term_id":54,"name":"\u52d5\u7684\u7c98\u5f3e\u6027\u6e2c\u5b9a","slug":"dma","term_group":0,"term_taxonomy_id":54,"taxonomy":"post_tag","description":"","parent":0,"count":3,"filter":"raw","meta":[]}],"jetpack-related-posts":[{"id":23425,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/twin-screw-extrusion-extruder-cad-25062\/","url_meta":{"origin":398,"position":0},"title":"\u4e8c\u8ef8\u62bc\u51fa\u6a5f\u306e\u57fa\u790e\u2465\uff1a\u30d7\u30ed\u30bb\u30b9\u30d1\u30e9\u30e1\u30fc\u30bf\u30fc","author":"LatB Staff","date":"2025\u5e7410\u670820\u65e5","format":false,"excerpt":"\u4e8c\u8ef8\u62bc\u51fa\u6a5f\u306e\u57fa\u790e\u30b7\u30ea\u30fc\u30ba\u3067\u306f\u88c5\u7f6e\u306e\u4ed5\u7d44\u307f\u3084\u7279\u9577\u3001\u30d1\u30e9\u30e1\u30fc\u30bf\u30fc\u8a2d\u5b9a\u3084\u305d\u306e\u610f\u5473\u3001\u5f8c\u5de5\u7a0b\u30aa\u30d7\u30b7\u30e7\u30f3\u3092\u7d44\u307f\u5408\u2026","rel":"","context":"\u305d\u306e\u4ed6","block_context":{"text":"\u305d\u306e\u4ed6","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/else\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/09\/twin-screw-extrusion-extruder-cad-25057_eyecatch.png?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/09\/twin-screw-extrusion-extruder-cad-25057_eyecatch.png?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/09\/twin-screw-extrusion-extruder-cad-25057_eyecatch.png?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/09\/twin-screw-extrusion-extruder-cad-25057_eyecatch.png?resize=700%2C400&ssl=1 2x"},"classes":[]},{"id":24026,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/twin-screw-extrusion-extruder-cad-25071\/","url_meta":{"origin":398,"position":1},"title":"\u4e8c\u8ef8\u62bc\u51fa\u6a5f\u306e\u57fa\u790e\u2466\uff1a\u6750\u6599\u4f9b\u7d66\u306e\u30dd\u30a4\u30f3\u30c8","author":"LatB Staff","date":"2025\u5e7411\u670819\u65e5","format":false,"excerpt":"\u4e8c\u8ef8\u62bc\u51fa\u6a5f\u306e\u57fa\u790e\u30b7\u30ea\u30fc\u30ba\u3067\u306f\u88c5\u7f6e\u306e\u4ed5\u7d44\u307f\u3084\u7279\u9577\u3001\u30d1\u30e9\u30e1\u30fc\u30bf\u30fc\u8a2d\u5b9a\u3084\u305d\u306e\u610f\u5473\u3001\u5f8c\u5de5\u7a0b\u30aa\u30d7\u30b7\u30e7\u30f3\u3092\u7d44\u307f\u5408\u2026","rel":"","context":"\u305d\u306e\u4ed6","block_context":{"text":"\u305d\u306e\u4ed6","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/else\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/11\/twin-screw-extrusion-extruder-cad-25071_eyecatch.png?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/11\/twin-screw-extrusion-extruder-cad-25071_eyecatch.png?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/11\/twin-screw-extrusion-extruder-cad-25071_eyecatch.png?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/11\/twin-screw-extrusion-extruder-cad-25071_eyecatch.png?resize=700%2C400&ssl=1 2x"},"classes":[]},{"id":24695,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/environmental-analysis-laboratory-lpd-26008\/","url_meta":{"origin":398,"position":2},"title":"Orion Pro Star pH\uff0fISE\u30e1\u30fc\u30bf\u30fc\u3067\u5b9f\u73fe\u3059\u308b\u30a2\u30f3\u30e2\u30cb\u30a2\u30a4\u30aa\u30f3\u306e\u8fc5\u901f\u30fb\u9ad8\u7cbe\u5ea6\u6e2c\u5b9a\u5165\u9580","author":"LatB Staff","date":"2026\u5e742\u670818\u65e5","format":false,"excerpt":"\u6c34\u8cea\u30fb\u5ec3\u6c34\u51e6\u7406\u306e\u73fe\u5834\u3067\u306f\u3001\u30a2\u30f3\u30e2\u30cb\u30a2\u6fc3\u5ea6\u306e\u7ba1\u7406\u306f\u51e6\u7406\u30d7\u30ed\u30bb\u30b9\u3092\u6b63\u5e38\u306b\u4fdd\u3061\u3001\u6cd5\u898f\u5236\u306b\u9069\u5408\u3059\u308b\u305f\u3081\u306b\u6b20\u304b\u2026","rel":"","context":"\u5206\u6790\u30fb\u6e2c\u5b9a\u95a2\u9023","block_context":{"text":"\u5206\u6790\u30fb\u6e2c\u5b9a\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/analysis\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/01\/environmental-analysis-laboratory-lpd-26008_eyecatch_.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/01\/environmental-analysis-laboratory-lpd-26008_eyecatch_.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/01\/environmental-analysis-laboratory-lpd-26008_eyecatch_.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/01\/environmental-analysis-laboratory-lpd-26008_eyecatch_.jpg?resize=700%2C400&ssl=1 2x"},"classes":[]},{"id":24408,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/elemental-analysis-case-introduction-cmd-25076\/","url_meta":{"origin":398,"position":3},"title":"LA-ICP-MS\u3067\u5b9f\u73fe\u3059\u308b\u7c89\u672b\u8a66\u6599\u306e\u8fc5\u901f\u30fb\u9ad8\u611f\u5ea6\u306a\u5143\u7d20\u5206\u6790","author":"LatB Staff","date":"2025\u5e7412\u670812\u65e5","format":false,"excerpt":"\u5316\u5b66\u54c1\u3084\u5de5\u696d\u6750\u6599\u306e\u539f\u6599\u3001\u304a\u3088\u3073\u4e8c\u6b21\u96fb\u6c60\u5411\u3051\u306e\u6a5f\u80fd\u6027\u6750\u6599\u306a\u3069\u3001\u7c89\u672b\u8a66\u6599\u3084\u30bb\u30e9\u30df\u30c3\u30af\u30b9\u6750\u6599\u4e2d\u306e\u5fae\u91cf\u5143\u7d20\u306e\u2026","rel":"","context":"\u5206\u6790\u30fb\u6e2c\u5b9a\u95a2\u9023","block_context":{"text":"\u5206\u6790\u30fb\u6e2c\u5b9a\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/analysis\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/12\/shutterstock_2249094135-scaled.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/12\/shutterstock_2249094135-scaled.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/12\/shutterstock_2249094135-scaled.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/12\/shutterstock_2249094135-scaled.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/12\/shutterstock_2249094135-scaled.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/12\/shutterstock_2249094135-scaled.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":24552,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/qubit-dna-bid-ts-mbr-26001\/","url_meta":{"origin":398,"position":4},"title":"Qubit Fluorometer\u306b\u3064\u3044\u3066 \uff5eQubit Assay Kit\u306e\u6e2c\u5b9a\u7bc4\u56f2\uff5e","author":"LatB Staff","date":"2026\u5e741\u67089\u65e5","format":false,"excerpt":"Invitrogen\u2122 Qubit\u2122 Fluorometer \u306f\u3001\u5c02\u7528\u306e\u8a66\u85ac\u30ad\u30c3\u30c8\u3092\u7528\u3044\u308b\u3053\u3068\u3067DN\u2026","rel":"","context":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","block_context":{"text":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/mol-bio\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/12\/qubit-dna-bid-ts-mbr-26001_eyecatch.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/12\/qubit-dna-bid-ts-mbr-26001_eyecatch.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/12\/qubit-dna-bid-ts-mbr-26001_eyecatch.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/12\/qubit-dna-bid-ts-mbr-26001_eyecatch.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/12\/qubit-dna-bid-ts-mbr-26001_eyecatch.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/12\/qubit-dna-bid-ts-mbr-26001_eyecatch.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":24587,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/twin-screw-extrusion-extruder-cad-26003\/","url_meta":{"origin":398,"position":5},"title":"\u4e8c\u8ef8\u62bc\u51fa\u6a5f\u306e\u57fa\u790e\u2468 \u5f8c\u5de5\u7a0b\u3068\u30b5\u30f3\u30d7\u30eb\u306e\u56de\u53ce \u30da\u30ec\u30bf\u30a4\u30ba","author":"LatB Staff","date":"2026\u5e741\u670822\u65e5","format":false,"excerpt":"\u66f4\u65b0\u65e5 : \u3053\u306e\u8a18\u4e8b\u306e\u8981\u70b9 \u30da\u30ec\u30bf\u30a4\u30ba\u306f\u4e8c\u8ef8\u62bc\u51fa\u6a5f\u306b\u3088\u308b\u30b3\u30f3\u30d1\u30a6\u30f3\u30c7\u30a3\u30f3\u30b0\u5f8c\u306e\u4ee3\u8868\u7684\u306a\u30b5\u30f3\u30d7\u30eb\u56de\u53ce\u6cd5\u2026","rel":"","context":"\u5206\u6790\u30fb\u6e2c\u5b9a\u95a2\u9023","block_context":{"text":"\u5206\u6790\u30fb\u6e2c\u5b9a\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/analysis\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/01\/twin-screw-extrusion-extruder-cad-26003_eyeycatch.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/01\/twin-screw-extrusion-extruder-cad-26003_eyeycatch.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/01\/twin-screw-extrusion-extruder-cad-26003_eyeycatch.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/01\/twin-screw-extrusion-extruder-cad-26003_eyeycatch.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/01\/twin-screw-extrusion-extruder-cad-26003_eyeycatch.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/01\/twin-screw-extrusion-extruder-cad-26003_eyeycatch.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]}],"jetpack_sharing_enabled":true,"amp_enabled":true,"jetpack_featured_media_url":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/viscoelasticity-basic-title.jpg","_links":{"self":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/posts\/398","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/users\/988"}],"replies":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/comments?post=398"}],"version-history":[{"count":0,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/posts\/398\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/media\/2646"}],"wp:attachment":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/media?parent=398"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/categories?post=398"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/tags?post=398"},{"taxonomy":"division","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/division?post=398"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}