{"id":409,"date":"2016-06-01T00:00:00","date_gmt":"2016-06-01T00:00:00","guid":{"rendered":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/viscoelasticity-basic2\/"},"modified":"2026-08-03T14:39:22","modified_gmt":"2026-08-03T05:39:22","slug":"viscoelasticity-basic2","status":"publish","type":"post","link":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/viscoelasticity-basic2\/","title":{"rendered":"\u52d5\u7684\u7c98\u5f3e\u6027\u6e2c\u5b9a\u306e\u5b9f\u6e2c\u4f8b\u3068\u30c7\u30fc\u30bf\u306e\u8aad\u307f\u65b9"},"content":{"rendered":"<h2>\u306f\u3057\u3099\u3081\u306b<\/h2>\n<p>\u524d\u56de\u306f\u3001\u7269\u6027\u3068\u3057\u3066\u306e\u7c98\u5f3e\u6027\u3068\u52d5\u7684\u7c98\u5f3e\u6027\u6e2c\u5b9a\u306e\u6982\u5ff5\u306b\u3064\u3044\u3066\u89e3\u8aac\u3057\u3001\u304a\u308f\u308a\u306b\u6c34\u3042\u3081\u3068\u30de\u30e8\u30cd\u30fc\u30b9\u3099\u3092\u4f8b\u306b\u53d6\u308a\u4e0a\u3051\u3099\u3066\u3001\u8907\u7d20\u5e73\u9762\u4e0a\u306b\u304a\u3051\u308b\u305d\u308c\u305d\u3099\u308c\u306e\u5f3e\u6027\u7387\u306e\u30a4\u30e1\u30fc\u30b7\u3099\u3092\u3064\u304b\u3093\u3066\u3099\u3044\u305f\u305f\u3099\u304d\u307e\u3057\u305f\u3002<\/p>\n<p>\u4eca\u56de\u306f\u3001<strong>\u3053\u308c\u3089\u306e\u52d5\u7684\u7c98\u5f3e\u6027\u8a66\u9a13\u3092\u884c\u3044\u3001<a href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/life-science\/lab-equipment\/rheometers-viscometers.html?CID=Social_LAB\" target=\"_blank\" rel=\"noopener noreferrer\">\u30ec\u30aa\u30e1\u30fc\u30bf\u30fc<\/a>\u306e\u5165\u9580\u6a5f\u3068\u3057\u3066\u6700\u9069\u306a<a href=\"https:\/\/www.thermofisher.com\/order\/catalog\/product\/262-0001TS?CID=Social_LAB\" target=\"_blank\" rel=\"noopener noreferrer\">HAAKE\u2122 Viscotester\u2122 iQ<\/a>\u3092\u3053\u3099\u7d39\u4ecb\u3057\u306a\u304b\u3099\u3089\u3001\u6e2c\u5b9a\u65b9\u6cd5\u3084\u5b9f\u969b\u306b\u6e2c\u5b9a\u3057\u305f\u30c6\u3099\u30fc\u30bf\u306e\u8aad\u307f\u65b9\u306b\u3064\u3044\u3066\u89e3\u8aac\u3057\u307e\u3059<\/strong>\u3002<\/p>\n<h2>HAAKE Viscotester iQ \u30ec\u30aa\u30e1\u30fc\u30bf\u30fc\u306e\u6982\u8981<\/h2>\n<p>\u4eca\u56de\u6e2c\u5b9a\u306b\u7528\u3044\u305f<a href=\"https:\/\/www.thermofisher.com\/order\/catalog\/product\/262-0001TS?CID=Social_LAB\" target=\"_blank\" rel=\"noopener noreferrer\">HAAKE Viscotester iQ \u30ec\u30aa\u30e1\u30fc\u30bf\u30fc<\/a>\u306f\u3001\u30b3\u30f3\u30cf\u309a\u30af\u30c8\u3066\u3099\u3042\u308a\u306a\u304b\u3099\u3089\u3001\u56de\u8ee2\u7c98\u5ea6\u305f\u3099\u3051\u3066\u3099\u306a\u304f\u30aa\u30b7\u30ec\u30fc\u30b7\u30e7\u30f3(\u632f\u52d5)\u306b\u3088\u308b\u7c98\u5f3e\u6027\u6e2c\u5b9a\u3082\u53ef\u80fd\u3066\u3099\u3059\u3002\u901a\u5e38\u3001\u30ec\u30aa\u30e1\u30fc\u30bf\u30fc\u306e\u52d5\u4f5c\u306b\u306f\u3001\u30ec\u30aa\u30e1\u30fc\u30bf\u30fc\u672c\u4f53\u306e\u307b\u304b\u306b\u30a8\u30a2\u30fc\u30b3\u30f3\u30d5\u309a\u30ec\u30c3\u30b5\u30fc\u3084\u5faa\u74b0\u6052\u6e29\u69fd\u306a\u3068\u3099\u306e\u4ed8\u5e2f\u8a2d\u5099\u304b\u3099\u5fc5\u8981\u3066\u3099\u3059\u304b\u3099\u3001<strong>\u6700\u65b0\u306e\u30c6\u30af\u30ce\u30ed\u30b7\u3099\u30fc\u3092\u99c6\u4f7f\u3057\u305fViscotester iQ\u306f\u3001\u672c\u4f53\u4e00\u53f0\u3066\u3099\u57fa\u672c\u7684\u306a\u30ec\u30aa\u30ed\u30b7\u3099\u30fc\u7279\u6027\u3092\u7db2\u7f85\u3059\u308b\u3053\u3068\u304b\u3099\u53ef\u80fd<\/strong>\u3066\u3099\u3059\u3002\u307e\u305f\u3001Viscotester iQ\u306f\u5fdc\u529b\u5236\u5fa1\u305f\u3099\u3051\u3066\u3099\u306a\u304f\u3001\u3072\u3059\u3099\u307f\u5236\u5fa1\u306b\u3082\u5bfe\u5fdc\u3057\u3001\u30b5\u30f3\u30d5\u309a\u30eb\u306e\u5fae\u5c0f\u306a\u69cb\u9020\u3092\u58ca\u3055\u3059\u3099\u306b\u6e2c\u5b9a\u3059\u308b\u3053\u3068\u304b\u3099\u3066\u3099\u304d\u307e\u3059\u3002<\/p>\n<h3>Viscotester iQ \u30ec\u30aa\u30e1\u30fc\u30bf\u30fc\u306e\u305d\u306e\u4ed6\u306e\u7279\u9577<\/h3>\n<ul>\n<li>\u30d8\u309a\u30eb\u30c1\u30a7\u5f0f\u9ad8\u7cbe\u5ea6\u6e29\u5ea6\u5236\u5fa1\u30e2\u30b7\u3099\u30e5\u30fc\u30eb:0 ~ 150 \u00baC\u307e\u3066\u3099\u5bfe\u5fdc<\/li>\n<li>\u672c\u4f53\u4e00\u53f0\u3066\u3099\u3001\u5171\u8ef8\u4e8c\u91cd\u5186\u7b52\u304a\u3088\u3072\u3099\u30d5\u309a\u30ec\u30fc\u30c8\u6e2c\u5b9a\u304b\u3099\u53ef\u80fd<\/li>\n<\/ul>\n<h2>\u6e2c\u5b9a\u6982\u8981<\/h2>\n<p>\u30aa\u30b7\u30ec\u30fc\u30b7\u30e7\u30f3\u306b\u3088\u308b\u6e2c\u5b9a\u3066\u3099\u306f\u3001\u30d5\u309a\u30ec\u30fc\u30c8\u306e\u9593\u306b\u631f\u3093\u305f\u3099\u8a66\u6599\u306b\u632f\u52d5\u306b\u3088\u308b\u5468\u671f\u7684\u306a\u3072\u3059\u3099\u307f(\u307e\u305f\u306f\u5fdc\u529b)\u3092\u5370\u52a0\u3057\u3001\u5fdc\u7b54\u3068\u3057\u3066\u306e\u305b\u3093\u65ad\u5fdc\u529b\u306e\u6ce2\u5f62\u3068\u305d\u308c\u3089\u306e\u4f4d\u76f8\u5dee\u304b\u3089\u3001\u8caf\u8535\u5f3e\u6027\u3084\u640d\u5931\u5f3e\u6027\u306a\u3068\u3099\u306e\u5404\u7c98\u5f3e\u6027\u7387\u3092\u6e2c\u5b9a\u3057\u307e\u3059 (\u56f31)\u3002<\/p>\n<div id=\"attachment_1219\" style=\"width: 526px\" class=\"wp-caption aligncenter\"><a href=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/viscoelasticity-basic2-fig1.jpg\" rel=\"attachment wp-att-1219\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-1219\" class=\"size-full wp-image-1219\" src=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/viscoelasticity-basic2-fig1.jpg\" alt=\"viscoelasticity-basic2-fig1\" width=\"516\" height=\"245\" \/><\/a><p id=\"caption-attachment-1219\" class=\"wp-caption-text\">\u56f31 \u6e2c\u5b9a\u90e8\u306e\u6982\u7565\u56f3<\/p><\/div>\n<p>\u4eca\u56de\u306f\u3001<strong>\u6c34\u3042\u3081\u3068\u30de\u30e8\u30cd\u30fc\u30b9\u3099\u3092\u7528\u3044\u3066\u7c98\u5f3e\u6027\u8a55\u4fa1\u3092\u884c\u3044\u3001\u52d5\u7684\u7c98\u5f3e\u6027\u8a66\u9a13\u306e\u3046\u3061\u3001\u632f\u5e45\u4f9d\u5b58\u6027\u6e2c\u5b9a\u306a\u3089\u3072\u3099\u306b\u5468\u6ce2\u6570\u4f9d\u5b58\u6027\u6e2c\u5b9a\u306e\u65b9\u6cd5\u3092\u7d39\u4ecb\u3057\u307e\u3059<\/strong>\u3002\u4ee5\u4e0b\u306b\u3001\u305d\u308c\u305d\u3099\u308c\u306e\u6e2c\u5b9a\u6982\u8981\u306b\u3064\u3044\u3066\u8aac\u660e\u3057\u307e\u3059\u3002<\/p>\n<h3>\u632f\u5e45\u4f9d\u5b58\u6027\u6e2c\u5b9a<\/h3>\n<p>\u672c\u6e2c\u5b9a\u3066\u3099\u306f\u3001\u4e00\u5b9a\u306e\u5468\u6ce2\u6570\u306e\u3082\u3068\u3066\u3099\u3072\u3059\u3099\u307f\u632f\u5e45\u3092\u6bb5\u968e\u7684\u306b\u5897\u5927\u3055\u305b\u3066\u3044\u304d\u3001\u305d\u306e\u3068\u304d\u306e\u5fdc\u7b54\u6ce2\u5f62\u3092\u89b3\u6e2c\u3057\u307e\u3059(\u56f32)\u3002<strong>\u5fae\u5c0f\u632f\u5e45\u304b\u3089\u6e2c\u5b9a\u3092\u958b\u59cb\u3059\u308b\u3053\u3068\u306b\u3088\u308a\u3001\u6750\u6599\u306e\u6301\u3064\u5fae\u7d30\u306a\u69cb\u9020\u306e\u628a\u63e1\u304b\u3089\u3001\u632f\u5e45\u306e\u5897\u5927\u306b\u4f34\u3046\u69cb\u9020\u7834\u58ca\u3084\u6d41\u52d5\u306b\u81f3\u308b\u307e\u3066\u3099\u306e\u4e00\u9023\u306e\u904e\u7a0b\u3092\u89b3\u5bdf\u3059\u308b\u3053\u3068\u304b\u3099\u3066\u3099\u304d\u307e\u3059<\/strong>\u3002<\/p>\n<div id=\"attachment_1220\" style=\"width: 370px\" class=\"wp-caption aligncenter\"><a href=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/viscoelasticity-basic2-fig2.jpg\" rel=\"attachment wp-att-1220\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-1220\" class=\"size-full wp-image-1220\" src=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/viscoelasticity-basic2-fig2.jpg\" alt=\"viscoelasticity-basic2-fig2\" width=\"360\" height=\"195\" \/><\/a><p id=\"caption-attachment-1220\" class=\"wp-caption-text\">\u56f32 \u52d5\u7684\u3072\u3059\u3099\u307f\u4f9d\u5b58\u6027\u6e2c\u5b9a\u306e\u30a4\u30e1\u30fc\u30b7\u3099<\/p><\/div>\n<h3>\u5468\u6ce2\u6570\u5b58\u6027\u6e2c\u5b9a<\/h3>\n<p>\u672c\u6e2c\u5b9a\u3066\u3099\u306f\u3001\u4e00\u5b9a\u306e\u3072\u3059\u3099\u307f\u91cf(\u3042\u308b\u3044\u306f\u5fdc\u529b)\u306e\u3082\u3068\u3066\u3099\u5468\u6ce2\u6570\u3092\u5f90\u3005\u306b\u5909\u5316\u3055\u305b\u3066\u3044\u304d\u3001\u305d\u306e\u3068\u304d\u306e\u5fdc\u7b54\u6ce2\u5f62\u3092\u89b3\u6e2c\u3057\u307e\u3059(\u56f33)\u3002<strong>\u4e00\u74b0\u3057\u3066\u5fae\u5c0f\u632f\u5e45\u3092\u4e0e\u3048\u3066\u6e2c\u5b9a\u3059\u308b\u3053\u3068\u306b\u306a\u308b\u305f\u3081\u3001\u69cb\u9020\u3092\u7834\u58ca\u3059\u308b\u3053\u3068\u306a\u304f\u3001\u7d14\u7c8b\u306b\u5468\u6ce2\u6570(\u901f\u5ea6\u3084\u6642\u9593\u306b\u5bfe\u5fdc)\u306b\u5bfe\u3059\u308b\u4f9d\u5b58\u6027\u3092\u8a55\u4fa1\u3066\u3099\u304d\u307e\u3059<\/strong>\u3002<\/p>\n<div id=\"attachment_1221\" style=\"width: 366px\" class=\"wp-caption aligncenter\"><a href=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/viscoelasticity-basic2-fig3.jpg\" rel=\"attachment wp-att-1221\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-1221\" class=\"size-full wp-image-1221\" src=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/viscoelasticity-basic2-fig3.jpg\" alt=\"viscoelasticity-basic2-fig3\" width=\"356\" height=\"201\" \/><\/a><p id=\"caption-attachment-1221\" class=\"wp-caption-text\">\u56f33 \u52d5\u7684\u5468\u6ce2\u6570\u4f9d\u5b58\u6027\u6e2c\u5b9a\u306e\u30a4\u30e1\u30fc\u30b7\u3099<\/p><\/div>\n<h3>\u6e2c\u5b9a\u6761\u4ef6<\/h3>\n<ul>\n<li>\u5171\u901a\n<ul>\n<li>\u30b7\u3099\u30aa\u30e1\u30c8\u30ea: \u03c6 60 mm\u30cf\u309a\u30e9\u30ec\u30eb\u30d5\u309a\u30ec\u30fc\u30c8<\/li>\n<li>\u30ad\u3099\u30e3\u30c3\u30d5\u309a: 0.5 mm<\/li>\n<li>\u6e29\u5ea6: 20\u00b0C<\/li>\n<\/ul>\n<\/li>\n<li>\u632f\u5e45\u4f9d\u5b58\u6027\u6e2c\u5b9a\n<ul>\n<li>\u5468\u6ce2\u6570: 1 Hz(\u56fa\u5b9a)<\/li>\n<li>\u3072\u3059\u3099\u307f\u91cf\u7bc4\u56f2: 0.006 ~ 600%<\/li>\n<\/ul>\n<\/li>\n<li>\u5468\u6ce2\u6570\u4f9d\u5b58\u6027\u6e2c\u5b9a\n<ul>\n<li>\u5468\u6ce2\u6570: 20 ~ 0.1Hz<\/li>\n<li>\u3072\u3059\u3099\u307f\u91cf: 0.02%(\u56fa\u5b9a)<\/li>\n<\/ul>\n<\/li>\n<\/ul>\n<h2>\u6e2c\u5b9a\u7d50\u679c\u304a\u3088\u3072\u3099\u8a55\u4fa1<\/h2>\n<p>\u4ee5\u4e0b\u306b\u3001\u52d5\u7684\u7c98\u5f3e\u6027\u306b\u3088\u308b\u632f\u5e45\u4f9d\u5b58\u6027\u6e2c\u5b9a\u304a\u3088\u3073\u5468\u6ce2\u6570\u4f9d\u5b58\u6027\u6e2c\u5b9a\u306e\u7d50\u679c\u3092\u793a\u3057\u307e\u3059\u3002<\/p>\n<h3>\u632f\u5e45\u4f9d\u5b58\u6027\u6e2c\u5b9a<\/h3>\n<p>\u56f34\u306f\u3001\u3072\u3059\u3099\u307f\u91cf\u3068\u8907\u7d20\u5f3e\u6027\u7387[G*](\u3072\u3059\u3099\u307f\u91cf\u3068\u5fdc\u7b54\u5fdc\u529b\u306e\u6bd4)\u306e\u95a2\u4fc2\u3092\u793a\u3057\u3066\u3044\u307e\u3059\u3002<strong>[G*]\u304b\u3099\u5927\u304d\u3044\u3068\u3044\u3046\u3053\u3068\u306f\u3001\u540c\u3057\u3099\u91cf\u3092\u5909\u5f62\u3055\u305b\u308b\u5834\u5408\u306b\u3001\u3088\u308a\u5927\u304d\u306a\u529b\u3092\u8981\u3059\u308b\u3053\u3068\u3092\u610f\u5473\u3057\u307e\u3059<\/strong>\u3002\u56f34\u306e\u7d50\u679c\u304b\u3089\u3001<strong>\u30de\u30e8\u30cd\u30fc\u30b9\u3099\u3088\u308a\u3082\u6c34\u3042\u3081\u306e\u65b9\u304b\u3099[G*]\u304b\u3099\u5927\u304d\u3044\u3053\u3068\u304b\u3099\u5206\u304b\u308a\u307e\u3059<\/strong>\u3002\u6c34\u3042\u3081\u3068\u30de\u30e8\u30cd\u30fc\u30b9\u3099\u3092\u6307\u3066\u3099\u62bc\u3057\u305f\u3068\u304d\u306b\u6c34\u3042\u3081\u306e\u65b9\u304b\u3099\u62b5\u6297\u3092\u611f\u3057\u3099\u308b\u3053\u3068\u304b\u3089\u3082\u3001\u5b9f\u969b\u306e\u73fe\u8c61\u3068\u4e00\u81f4\u3057\u3066\u3044\u308b\u3053\u3068\u304b\u3099\u5206\u304b\u308a\u307e\u3059\u3002<\/p>\n<div id=\"attachment_1222\" style=\"width: 601px\" class=\"wp-caption aligncenter\"><a href=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/viscoelasticity-basic2-fig4.jpg\" rel=\"attachment wp-att-1222\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-1222\" class=\"size-full wp-image-1222\" src=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/viscoelasticity-basic2-fig4.jpg\" alt=\"viscoelasticity-basic2-fig4\" width=\"591\" height=\"291\" \/><\/a><p id=\"caption-attachment-1222\" class=\"wp-caption-text\">\u56f34 \u6c34\u3042\u3081\u3068\u30de\u30e8\u30cd\u30fc\u30ba\u306e\u632f\u5e45\u4f9d\u5b58\u6027\u6e2c\u5b9a (\u8907\u7d20\u5f3e\u6027\u7387\u8868\u793a)<\/p><\/div>\n<p>\u56f35\u306f\u3001\u8907\u7d20\u5f3e\u6027\u7387[G*]\u3092\u3055\u3089\u306b\u4e8c\u3064\u306e\u5f3e\u6027\u7387\u306b\u6210\u5206\u5206\u3051\u3057\u305f\u7d50\u679c\u3066\u3099\u3059\u3002[G\u2019]\u306f\u8caf\u8535\u5f3e\u6027\u7387\u3068\u547c\u306f\u3099\u308c\u3001\u30d5\u30c3\u30af\u306e\u6cd5\u5247\u306b\u57fa\u3064\u3099\u304f\u5f3e\u6027\u7387\u3066\u3099\u3042\u308a\u3001[G\u201d]\u306f\u640d\u5931\u5f3e\u6027\u7387\u3068\u547c\u306f\u3099\u308c\u3001\u30cb\u30e5\u30fc\u30c8\u30f3\u306e\u6cd5\u5247\u306b\u57fa\u3064\u3099\u304f\u5f3e\u6027\u7387\u3066\u3099\u3059\u3002<strong>[G*]\u306f\u56fa\u4f53\u7684\u306a\u8981\u7d20\u3001[G\u201d]\u306f\u7c98\u6027(\u6db2\u4f53)\u7684\u306a\u8981\u7d20\u3068\u3057\u3066\u3068\u3089\u3048\u308b\u3068\u30a4\u30e1\u30fc\u30b7\u3099\u3057\u3084\u3059\u3044\u304b\u3082\u3057\u308c\u307e\u305b\u3093<\/strong>\u3002<\/p>\n<p>\u6c34\u3042\u3081\u3068\u30de\u30e8\u30cd\u30fc\u30b9\u3099\u3066\u3099\u305d\u308c\u305d\u3099\u308c\u306e\u5f3e\u6027\u7387\u306e\u6bd4\u7387\u3092\u6bd4\u8f03\u3059\u308b\u3068\u3001\u6c34\u3042\u3081\u3066\u3099\u306f\u7d42\u59cbG\u201d&gt;G\u2019\u306e\u95a2\u4fc2\u3066\u3099\u3042\u308b\u3053\u3068\u304b\u3089\u3001\u5909\u5f62(\u3072\u3059\u3099\u307f\u91cf)\u306e\u5927\u304d\u3055\u306b\u3088\u3089\u3059\u3099\u300c\u6d41\u4f53\u300d\u3066\u3099\u3042\u308b\u3053\u3068\u304b\u3099\u308f\u304b\u308a\u307e\u3059\u3002\u4e00\u65b9\u3001\u30de\u30e8\u30cd\u30fc\u30b9\u3099\u306f\u4f4e\u3072\u3059\u3099\u307f\u91cf\u3066\u3099\u306fG\u2019&gt;G\u201d\u3066\u3099\u3042\u308a\u3001\u9014\u4e2d\u304b\u3089\u9006\u8ee2\u3057\u3066G\u201d&gt;G\u2019\u3068\u306a\u308b\u3053\u3068\u304b\u3089\u3001\u5fae\u5c0f\u5909\u5f62(\u9759\u7f6e\u306b\u8fd1\u3044\u72b6\u614b)\u6642\u306f\u56fa\u4f53\u7684\u306b\u632f\u308b\u821e\u3044\u3001\u5909\u5f62\u3092\u5927\u304d\u304f\u3057\u3066\u3044\u304f\u3068\u56fa\u4f53\u3068\u3057\u3066\u7dad\u6301\u3057\u3066\u3044\u305f\u69cb\u9020\u304b\u3099\u58ca\u3055\u308c\u3066\u6d41\u52d5\u306b\u8ee2\u3057\u3099\u308b\u3053\u3068\u304b\u3099\u5206\u304b\u308a\u307e\u3059\u3002\u30de\u30e8\u30cd\u30fc\u30b9\u3099\u306e\u30c1\u30e5\u30fc\u30d5\u3099\u3092\u9006\u3055\u306b\u3057\u3066\u3082\u5782\u308c\u843d\u3061\u3066\u3053\u306a\u3044\u3053\u3068\u306f\u3001\u3053\u306e\u30c6\u3099\u30fc\u30bf\u304b\u3089\u985e\u63a8\u3066\u3099\u304d\u307e\u3059\u3002<\/p>\n<div id=\"attachment_1223\" style=\"width: 602px\" class=\"wp-caption aligncenter\"><a href=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/viscoelasticity-basic2-fig5.jpg\" rel=\"attachment wp-att-1223\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-1223\" class=\"size-full wp-image-1223\" src=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/viscoelasticity-basic2-fig5.jpg\" alt=\"viscoelasticity-basic2-fig5\" width=\"592\" height=\"285\" \/><\/a><p id=\"caption-attachment-1223\" class=\"wp-caption-text\">\u56f35 \u6c34\u3042\u3081\u3068\u30de\u30e8\u30cd\u30fc\u30b9\u3099\u306e\u632f\u5e45\u4f9d\u5b58\u6027\u6e2c\u5b9a (\u8caf\u8535\u5f3e\u6027\u7387\u30fb\u640d\u5931\u5f3e\u6027\u7387\u8868\u793a)<\/p><\/div>\n<h3>\u5468\u6ce2\u6570\u4f9d\u5b58\u6027\u6e2c\u5b9a<\/h3>\n<p>\u3053\u306e\u6e2c\u5b9a\u3067\u306f\u3001\u4e8c\u7a2e\u985e\u306e\u30de\u30e8\u30cd\u30fc\u30ba\u3092\u4f7f\u3063\u3066\u7c98\u5f3e\u6027\u306e\u9055\u3044\u3092\u8aac\u660e\u3057\u307e\u3059\u3002\u56f36\u306b\u306f\u3001\u4f4d\u76f8\u5dee[\u03b4]\u306a\u3089\u3072\u3099\u306b\u8907\u7d20\u5f3e\u6027\u7387[G*]\u3092\u793a\u3057\u3066\u3044\u307e\u3059\u3002\u6a2a\u8ef8\u306e\u5468\u6ce2\u6570\u306f\u6642\u9593\u306b\u7f6e\u304d\u63db\u3048\u3066\u8003\u3048\u308b\u3053\u3068\u3082\u3066\u3099\u304d\u3001\u305d\u306e\u5834\u5408\u3001\u9ad8\u5468\u6ce2\u6570(\u9ad8\u901f)\u5074\u306f\u77ed\u6642\u9593\u3066\u3099\u306e\u52d5\u304d\u3092\u6e2c\u5b9a\u3057\u3001\u4f4e\u5468\u6ce2\u6570(\u4f4e\u901f)\u5074\u306f\u9577\u6642\u9593\u6e2c\u5b9a\u3057\u305f\u3053\u3068\u3068\u540c\u3057\u3099\u306b\u306a\u308a\u307e\u3059\u3002\u4f4d\u76f8\u5dee\u306f45\u00b0\u3092\u5883\u306b\u3057\u3066\u3001\u5927\u304d\u304f\u306a\u308b\u307b\u3068\u3099\u8907\u7d20\u5f3e\u6027\u7387\u306b\u5360\u3081\u308b\u640d\u5931\u5f3e\u6027\u7387[G\u201d]\u306e\u6bd4\u7387\u304b\u3099\u652f\u914d\u7684\u306b\u306a\u308b\u3053\u3068\u3092\u793a\u3057\u3001\u9006\u306b\u5c0f\u3055\u304f\u306a\u308b\u307b\u3068\u3099\u8caf\u8535\u5f3e\u6027\u7387[G\u2019]\u304b\u3099\u652f\u914d\u7684\u306b\u306a\u308b\u3053\u3068\u3092\u793a\u3057\u307e\u3059\u3002<\/p>\n<div id=\"attachment_1224\" style=\"width: 600px\" class=\"wp-caption aligncenter\"><a href=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/viscoelasticity-basic2-fig6.jpg\" rel=\"attachment wp-att-1224\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-1224\" class=\"size-full wp-image-1224\" src=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/viscoelasticity-basic2-fig6.jpg\" alt=\"viscoelasticity-basic2-fig6\" width=\"590\" height=\"291\" \/><\/a><p id=\"caption-attachment-1224\" class=\"wp-caption-text\">\u56f36 \u4e8c\u7a2e\u306e\u30de\u30e8\u30cd\u30fc\u30b9\u3099\u306e\u5468\u6ce2\u6570\u4f9d\u5b58\u6027\u6e2c\u5b9a<\/p><\/div>\n<p>\u56f36\u3088\u308a\u3001<strong>\u8907\u7d20\u5f3e\u6027\u7387[G*]\u306f\u6e2c\u5b9a\u7bc4\u56f2\u5168\u57df\u3066\u3099\u30de\u30e8\u30cd\u30fc\u30b9\u3099A\u306e\u65b9\u304cB\u3088\u308a\u3082\u9ad8\u304f\u3001\u76f8\u5bfe\u7684\u306b\u300c\u786c\u3044\u300d\u3053\u3068<\/strong>\u304c\u8aad\u307f\u53d6\u308c\u307e\u3059\u3002\u4f4d\u76f8\u5dee\u306b\u7740\u76ee\u3059\u308b\u3068\u3001\u4e21\u8005\u3068\u3082\u306b\u6e2c\u5b9a\u7bc4\u56f2\u5168\u57df\u306b\u308f\u305f\u308a45\u00b0\u4ee5\u4e0b\u3066\u3099\u63a8\u79fb\u3057\u3066\u3044\u308b\u3053\u3068\u304b\u3089\u3001\u300c\u56fa\u4f53\u7684\u300d\u3066\u3099\u3042\u308b\u3053\u3068\u304b\u3099\u5206\u304b\u308a\u307e\u3059\u3002<strong>A\u306e\u65b9\u304b\u3099\u4f4d\u76f8\u5dee\u306e\u5024\u304b\u3099\u4f4e\u304f\u3001\u307e\u305f\u6e2c\u5b9a\u7bc4\u56f2\u306b\u304a\u3044\u3066\u5909\u5316\u304b\u3099\u5c0f\u3055\u3044\u3053\u3068\u304b\u3089\u300c\u4fdd\u5f62\u6027\u300d\u304b\u3099\u9ad8\u3044\u3053\u3068<\/strong>\u304b\u3099\u63a8\u5bdf\u3055\u308c\u307e\u3059\u3002\u3053\u308c\u306f\u3001\u5b9f\u969b\u306b\u9759\u7f6e\u3057\u305f\u30de\u30e8\u30cd\u30fc\u30b9\u3099\u3092\u89b3\u5bdf\u3057\u305f\u7d50\u679c(\u56f37)\u3068\u3082\u4e00\u81f4\u3057\u3066\u3044\u308b\u3053\u3068\u304b\u3099\u5206\u304b\u308a\u307e\u3057\u305f\u3002<br \/>\n<a href=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/viscoelasticity-basic2-fig7.jpg\" rel=\"attachment wp-att-1225\"><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter size-full wp-image-1225\" src=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/viscoelasticity-basic2-fig7.jpg\" alt=\"viscoelasticity-basic2-fig7\" width=\"623\" height=\"447\" \/><\/a><\/p>\n<h2>\u307e\u3068\u3081<\/h2>\n<p>\u4eca\u56de\u306f\u3001\u7c98\u5f3e\u6027\u7279\u6027\u304b\u3099\u5927\u304d\u304f\u7570\u306a\u308a\u3001\u5b9f\u969b\u306e\u73fe\u8c61\u3068\u7d50\u3072\u3099\u3064\u3051\u3084\u3059\u3044\u6c34\u3042\u3081\u3068\u30de\u30e8\u30cd\u30fc\u30b9\u3099\u3092\u984c\u6750\u306b\u3001\u52d5\u7684\u7c98\u5f3e\u6027\u6e2c\u5b9a\u306e\u6982\u8981\u3084\u6e2c\u5b9a\u30c6\u3099\u30fc\u30bf\u306e\u8aad\u307f\u65b9\u3001\u8a55\u4fa1\u4f8b\u306b\u3064\u3044\u3066\u89e3\u8aac\u3057\u307e\u3057\u305f\u3002\u6b21\u56de\u306f\u3001\u52d5\u7684\u7c98\u5f3e\u6027\u6e2c\u5b9a\u306e\u8a73\u7d30\u306a\u6761\u4ef6\u8a2d\u5b9a\u624b\u9806\u3084\u305d\u306e\u8003\u3048\u65b9\u306b\u3064\u3044\u3066\u3053\u3099\u7d39\u4ecb\u3057\u307e\u3059\u3002<\/p>\n<h1>\u30ec\u30aa\u30e1\u30fc\u30bf\u30fc\u3084\u7c98\u5ea6\u8a08\u88fd\u54c1\u306b\u95a2\u3059\u308b\u304a\u554f\u3044\u5408\u308f\u305b<\/h1>\n<p>\u3044\u304b\u304c\u3060\u3063\u305f\u3067\u3057\u3087\u3046\u304b\uff1f\u3000\u4eca\u56de\u8a18\u4e8b\u3066\u3099\u30ab\u30cf\u3099\u30fc\u3066\u3099\u304d\u306a\u304b\u3063\u305f\u9ad8\u5ea6\u306a\u7528\u9014\u306b\u3064\u3044\u3066\u306f\u3001\u5f0a\u793e\u306e\u6280\u8853\u30c6\u30af\u30cb\u30ab\u30eb\u30b5\u30db\u309a\u30fc\u30c8\u307e\u3066\u3099\u3053\u3099\u76f8\u8ac7\u304f\u305f\u3099\u3055\u3044\uff08\u6700\u4e0b\u90e8\u30d5\u30a9\u30fc\u30e0\u53c2\u7167\uff09\u3002<\/p>\n<p>\u305d\u306e\u4ed6\u3001\u30ec\u30aa\u30e1\u30fc\u30bf\u30fc\u3084\u7c98\u5ea6\u8a08\u88fd\u54c1\u306b\u3064\u3044\u3066<\/p>\n<ul style=\"list-style-type: disc\">\n<li><strong>\u30c7\u30e2<\/strong>\u3092\u4f9d\u983c\u3057\u305f\u3044<\/li>\n<li><strong>\u898b\u7a4d\u3082\u308a<\/strong>\u304c\u307b\u3057\u3044<\/li>\n<li>\u305d\u306e\u4ed6\uff08<strong>\u8cc7\u6599\u304c\u307b\u3057\u3044\u3001\u8a71\u3092\u805e\u3044\u3066\u307f\u305f\u3044\u3001\u62c5\u5f53\u8005\u304b\u3089\u9023\u7d61\u304c\u307b\u3057\u3044<\/strong> \u7b49\uff09<\/li>\n<\/ul>\n<p>\u7b49\u306e\u3054\u8981\u671b\u304c\u3042\u308a\u307e\u3057\u305f\u3089\u3001\u4e0b\u8a18\u30dc\u30bf\u30f3\u3088\u308a\u304a\u6c17\u8efd\u306b\u3054\u76f8\u8ac7\u304f\u3060\u3055\u3044\u3002<\/p>\n<p><a class=\"btn btn-red ext-link wpel-icon-right\" href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/life-science\/lab-equipment\/rheometers-viscometers\/rheometers-inquiry.html?CID=Social_LAB\" target=\"_blank\" rel=\"external noopener noreferrer\">\u30ec\u30aa\u30e1\u30fc\u30bf\u30fc\u3084\u7c98\u5ea6\u8a08\u88fd\u54c1\u306b\u95a2\u3059\u308b\u304a\u554f\u3044\u5408\u308f\u305b\u306f\u3053\u3061\u3089<\/a><\/p>\n<p>\u7814\u7a76\u7528\u306b\u306e\u307f\u4f7f\u7528\u3067\u304d\u307e\u3059\u3002\u8a3a\u65ad\u7528\u306b\u306f\u4f7f\u7528\u3044\u305f\u3060\u3051\u307e\u305b\u3093\u3002<\/p>\n","protected":false},"excerpt":{"rendered":"<p>\u4eca\u56de\u306f\u3001\u6c34\u3042\u3081\u3068\u30de\u30e8\u30cd\u30fc\u30ba\u3092\u4f8b\u306b\u53d6\u308a\u4e0a\u3052\u3066\u3001\u3053\u308c\u3089\u306e\u52d5\u7684\u7c98\u5f3e\u6027\u8a66\u9a13\u3092\u884c\u3044\u3001\u30ec\u30aa\u30e1\u30fc\u30bf\u30fc\u306e\u5165\u9580\u6a5f\u3068\u3057\u3066\u6700\u9069\u306aHAAKE&#x2122; Viscotester&#x2122; iQ\u3092\u3054\u7d39\u4ecb\u3057\u306a\u304c\u3089\u3001\u6e2c\u5b9a\u65b9\u6cd5\u3084\u5b9f\u969b\u306b\u6e2c\u5b9a\u3057\u305f\u30c7\u30fc\u30bf\u306e\u8aad\u307f\u65b9\u306b\u3064\u3044\u3066\u89e3\u8aac\u3057\u307e\u3059\u3002<\/p>\n","protected":false},"author":988,"featured_media":2666,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_monsterinsights_skip_tracking":false,"_genesis_hide_title":false,"_genesis_hide_breadcrumbs":false,"_genesis_hide_singular_image":false,"_genesis_hide_footer_widgets":false,"_genesis_custom_body_class":"","_genesis_custom_post_class":"","_genesis_layout":"","_jetpack_newsletter_access":"","_jetpack_dont_email_post_to_subs":false,"_jetpack_newsletter_tier_id":0,"_jetpack_memberships_contains_paywalled_content":false,"_jetpack_hide_featured_image":false,"_jetpack_featured_image_duplicate_dismissed":0,"_jetpack_feature_clip_id":0,"_jetpack_memberships_contains_paid_content":false,"footnotes":"","jetpack_post_was_ever_published":false},"categories":[157],"tags":[54],"division":[],"class_list":["post-409","post","type-post","status-publish","format-standard","has-post-thumbnail","category-analysis","tag-dma","entry"],"_selected_authors":[],"_selected_reviewers":[],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v28.9 (Yoast SEO v28.9) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>\u52d5\u7684\u7c98\u5f3e\u6027\u6e2c\u5b9a\u306e\u5b9f\u6e2c\u4f8b\u3068\u30c7\u30fc\u30bf\u306e\u8aad\u307f\u65b9 - Learning at the Bench<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/viscoelasticity-basic2\/\" \/>\n<meta property=\"og:locale\" content=\"ja_JP\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"\u52d5\u7684\u7c98\u5f3e\u6027\u6e2c\u5b9a\u306e\u5b9f\u6e2c\u4f8b\u3068\u30c7\u30fc\u30bf\u306e\u8aad\u307f\u65b9\" \/>\n<meta property=\"og:description\" content=\"\u4eca\u56de\u306f\u3001\u6c34\u3042\u3081\u3068\u30de\u30e8\u30cd\u30fc\u30ba\u3092\u4f8b\u306b\u53d6\u308a\u4e0a\u3052\u3066\u3001\u3053\u308c\u3089\u306e\u52d5\u7684\u7c98\u5f3e\u6027\u8a66\u9a13\u3092\u884c\u3044\u3001\u30ec\u30aa\u30e1\u30fc\u30bf\u30fc\u306e\u5165\u9580\u6a5f\u3068\u3057\u3066\u6700\u9069\u306aHAAKE&#x2122; Viscotester&#x2122; iQ\u3092\u3054\u7d39\u4ecb\u3057\u306a\u304c\u3089\u3001\u6e2c\u5b9a\u65b9\u6cd5\u3084\u5b9f\u969b\u306b\u6e2c\u5b9a\u3057\u305f\u30c7\u30fc\u30bf\u306e\u8aad\u307f\u65b9\u306b\u3064\u3044\u3066\u89e3\u8aac\u3057\u307e\u3059\u3002\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/viscoelasticity-basic2\/\" \/>\n<meta property=\"og:site_name\" content=\"Learning at the Bench\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/ThermoFisherJapan\" \/>\n<meta property=\"article:published_time\" content=\"2016-06-01T00:00:00+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2026-08-03T05:39:22+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/viscoelasticity-basic-title-1.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"1200\" \/>\n\t<meta property=\"og:image:height\" content=\"630\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"LATB Staff\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:creator\" content=\"@ThermoFisherJP\" \/>\n<meta name=\"twitter:site\" content=\"@ThermoFisherJP\" \/>\n<meta name=\"twitter:label1\" content=\"\u57f7\u7b46\u8005\" \/>\n\t<meta name=\"twitter:data1\" content=\"LATB Staff\" \/>\n\t<meta name=\"twitter:label2\" content=\"\u63a8\u5b9a\u8aad\u307f\u53d6\u308a\u6642\u9593\" \/>\n\t<meta name=\"twitter:data2\" content=\"10\u5206\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/viscoelasticity-basic2\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/viscoelasticity-basic2\\\/\"},\"author\":{\"name\":\"LATB Staff\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#\\\/schema\\\/person\\\/201e6a5abb838fa34e8ff0174b015d36\"},\"headline\":\"\u52d5\u7684\u7c98\u5f3e\u6027\u6e2c\u5b9a\u306e\u5b9f\u6e2c\u4f8b\u3068\u30c7\u30fc\u30bf\u306e\u8aad\u307f\u65b9\",\"datePublished\":\"2016-06-01T00:00:00+00:00\",\"dateModified\":\"2026-08-03T05:39:22+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/viscoelasticity-basic2\\\/\"},\"wordCount\":87,\"commentCount\":0,\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/viscoelasticity-basic2\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2019\\\/07\\\/viscoelasticity-basic-title-1.jpg\",\"keywords\":[\"\u52d5\u7684\u7c98\u5f3e\u6027\u6e2c\u5b9a\"],\"articleSection\":[\"\u5206\u6790\u30fb\u6e2c\u5b9a\u95a2\u9023\"],\"inLanguage\":\"ja\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/viscoelasticity-basic2\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/viscoelasticity-basic2\\\/\",\"url\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/viscoelasticity-basic2\\\/\",\"name\":\"\u52d5\u7684\u7c98\u5f3e\u6027\u6e2c\u5b9a\u306e\u5b9f\u6e2c\u4f8b\u3068\u30c7\u30fc\u30bf\u306e\u8aad\u307f\u65b9 - Learning at the Bench\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/viscoelasticity-basic2\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/viscoelasticity-basic2\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2019\\\/07\\\/viscoelasticity-basic-title-1.jpg\",\"datePublished\":\"2016-06-01T00:00:00+00:00\",\"dateModified\":\"2026-08-03T05:39:22+00:00\",\"author\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#\\\/schema\\\/person\\\/201e6a5abb838fa34e8ff0174b015d36\"},\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/viscoelasticity-basic2\\\/#breadcrumb\"},\"inLanguage\":\"ja\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/viscoelasticity-basic2\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"ja\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/viscoelasticity-basic2\\\/#primaryimage\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2019\\\/07\\\/viscoelasticity-basic-title-1.jpg\",\"contentUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2019\\\/07\\\/viscoelasticity-basic-title-1.jpg\",\"width\":1200,\"height\":630,\"caption\":\"viscoelasticity-basic-title\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/viscoelasticity-basic2\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"\u52d5\u7684\u7c98\u5f3e\u6027\u6e2c\u5b9a\u306e\u5b9f\u6e2c\u4f8b\u3068\u30c7\u30fc\u30bf\u306e\u8aad\u307f\u65b9\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#website\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/\",\"name\":\"Learning at the Bench\",\"description\":\"\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"ja\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#\\\/schema\\\/person\\\/201e6a5abb838fa34e8ff0174b015d36\",\"name\":\"LATB Staff\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"ja\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/8803277856c8b753feb4217dff0f9953327452df1a615c3c88b2f9864efb2ddd?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/8803277856c8b753feb4217dff0f9953327452df1a615c3c88b2f9864efb2ddd?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/8803277856c8b753feb4217dff0f9953327452df1a615c3c88b2f9864efb2ddd?s=96&d=mm&r=g\",\"caption\":\"LATB Staff\"},\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/author\\\/latbstaff\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"\u52d5\u7684\u7c98\u5f3e\u6027\u6e2c\u5b9a\u306e\u5b9f\u6e2c\u4f8b\u3068\u30c7\u30fc\u30bf\u306e\u8aad\u307f\u65b9 - Learning at the Bench","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/viscoelasticity-basic2\/","og_locale":"ja_JP","og_type":"article","og_title":"\u52d5\u7684\u7c98\u5f3e\u6027\u6e2c\u5b9a\u306e\u5b9f\u6e2c\u4f8b\u3068\u30c7\u30fc\u30bf\u306e\u8aad\u307f\u65b9","og_description":"\u4eca\u56de\u306f\u3001\u6c34\u3042\u3081\u3068\u30de\u30e8\u30cd\u30fc\u30ba\u3092\u4f8b\u306b\u53d6\u308a\u4e0a\u3052\u3066\u3001\u3053\u308c\u3089\u306e\u52d5\u7684\u7c98\u5f3e\u6027\u8a66\u9a13\u3092\u884c\u3044\u3001\u30ec\u30aa\u30e1\u30fc\u30bf\u30fc\u306e\u5165\u9580\u6a5f\u3068\u3057\u3066\u6700\u9069\u306aHAAKE&#x2122; Viscotester&#x2122; iQ\u3092\u3054\u7d39\u4ecb\u3057\u306a\u304c\u3089\u3001\u6e2c\u5b9a\u65b9\u6cd5\u3084\u5b9f\u969b\u306b\u6e2c\u5b9a\u3057\u305f\u30c7\u30fc\u30bf\u306e\u8aad\u307f\u65b9\u306b\u3064\u3044\u3066\u89e3\u8aac\u3057\u307e\u3059\u3002","og_url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/viscoelasticity-basic2\/","og_site_name":"Learning at the Bench","article_publisher":"https:\/\/www.facebook.com\/ThermoFisherJapan","article_published_time":"2016-06-01T00:00:00+00:00","article_modified_time":"2026-08-03T05:39:22+00:00","og_image":[{"width":1200,"height":630,"url":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/viscoelasticity-basic-title-1.jpg","type":"image\/jpeg"}],"author":"LATB Staff","twitter_card":"summary_large_image","twitter_creator":"@ThermoFisherJP","twitter_site":"@ThermoFisherJP","twitter_misc":{"\u57f7\u7b46\u8005":"LATB Staff","\u63a8\u5b9a\u8aad\u307f\u53d6\u308a\u6642\u9593":"10\u5206"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/viscoelasticity-basic2\/#article","isPartOf":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/viscoelasticity-basic2\/"},"author":{"name":"LATB Staff","@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#\/schema\/person\/201e6a5abb838fa34e8ff0174b015d36"},"headline":"\u52d5\u7684\u7c98\u5f3e\u6027\u6e2c\u5b9a\u306e\u5b9f\u6e2c\u4f8b\u3068\u30c7\u30fc\u30bf\u306e\u8aad\u307f\u65b9","datePublished":"2016-06-01T00:00:00+00:00","dateModified":"2026-08-03T05:39:22+00:00","mainEntityOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/viscoelasticity-basic2\/"},"wordCount":87,"commentCount":0,"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/viscoelasticity-basic2\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/viscoelasticity-basic-title-1.jpg","keywords":["\u52d5\u7684\u7c98\u5f3e\u6027\u6e2c\u5b9a"],"articleSection":["\u5206\u6790\u30fb\u6e2c\u5b9a\u95a2\u9023"],"inLanguage":"ja","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/viscoelasticity-basic2\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/viscoelasticity-basic2\/","url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/viscoelasticity-basic2\/","name":"\u52d5\u7684\u7c98\u5f3e\u6027\u6e2c\u5b9a\u306e\u5b9f\u6e2c\u4f8b\u3068\u30c7\u30fc\u30bf\u306e\u8aad\u307f\u65b9 - Learning at the Bench","isPartOf":{"@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/viscoelasticity-basic2\/#primaryimage"},"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/viscoelasticity-basic2\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/viscoelasticity-basic-title-1.jpg","datePublished":"2016-06-01T00:00:00+00:00","dateModified":"2026-08-03T05:39:22+00:00","author":{"@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#\/schema\/person\/201e6a5abb838fa34e8ff0174b015d36"},"breadcrumb":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/viscoelasticity-basic2\/#breadcrumb"},"inLanguage":"ja","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/viscoelasticity-basic2\/"]}]},{"@type":"ImageObject","inLanguage":"ja","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/viscoelasticity-basic2\/#primaryimage","url":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/viscoelasticity-basic-title-1.jpg","contentUrl":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/viscoelasticity-basic-title-1.jpg","width":1200,"height":630,"caption":"viscoelasticity-basic-title"},{"@type":"BreadcrumbList","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/viscoelasticity-basic2\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/"},{"@type":"ListItem","position":2,"name":"\u52d5\u7684\u7c98\u5f3e\u6027\u6e2c\u5b9a\u306e\u5b9f\u6e2c\u4f8b\u3068\u30c7\u30fc\u30bf\u306e\u8aad\u307f\u65b9"}]},{"@type":"WebSite","@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#website","url":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/","name":"Learning at the Bench","description":"","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"ja"},{"@type":"Person","@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#\/schema\/person\/201e6a5abb838fa34e8ff0174b015d36","name":"LATB Staff","image":{"@type":"ImageObject","inLanguage":"ja","@id":"https:\/\/secure.gravatar.com\/avatar\/8803277856c8b753feb4217dff0f9953327452df1a615c3c88b2f9864efb2ddd?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/8803277856c8b753feb4217dff0f9953327452df1a615c3c88b2f9864efb2ddd?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/8803277856c8b753feb4217dff0f9953327452df1a615c3c88b2f9864efb2ddd?s=96&d=mm&r=g","caption":"LATB Staff"},"url":"https:\/\/admin.acceleratingscience.com\/author\/latbstaff\/"}]}},"taxonomy_info":{"category":[{"value":157,"label":"\u5206\u6790\u30fb\u6e2c\u5b9a\u95a2\u9023"}],"post_tag":[{"value":54,"label":"\u52d5\u7684\u7c98\u5f3e\u6027\u6e2c\u5b9a"}]},"featured_image_src_large":["https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/viscoelasticity-basic-title-1-1024x538.jpg",760,399,true],"author_info":{"display_name":"LATB Staff","author_link":"https:\/\/admin.acceleratingscience.com\/author\/latbstaff\/"},"comment_info":0,"category_info":[{"term_id":157,"name":"\u5206\u6790\u30fb\u6e2c\u5b9a\u95a2\u9023","slug":"analysis","term_group":0,"term_taxonomy_id":157,"taxonomy":"category","description":"","parent":0,"count":107,"filter":"raw","meta":[],"cat_ID":157,"category_count":107,"category_description":"","cat_name":"\u5206\u6790\u30fb\u6e2c\u5b9a\u95a2\u9023","category_nicename":"analysis","category_parent":0}],"tag_info":[{"term_id":54,"name":"\u52d5\u7684\u7c98\u5f3e\u6027\u6e2c\u5b9a","slug":"dma","term_group":0,"term_taxonomy_id":54,"taxonomy":"post_tag","description":"","parent":0,"count":3,"filter":"raw","meta":[]}],"jetpack-related-posts":[{"id":25734,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/drug-formulation-hot-melt-extrusion-cad-26032\/","url_meta":{"origin":409,"position":0},"title":"\u88fd\u5264\u3068\u539f\u6750\u6599\u306e\u7269\u7406\u7684\u304a\u3088\u3073\u71b1\u7684\u7279\u6027\u8a55\u4fa1\u3068\u88fd\u5264\u30d7\u30ed\u30bb\u30b9\u3078\u306e\u30d5\u30a3\u30fc\u30c9\u30d0\u30c3\u30af","author":"LatB Staff","date":"2026\u5e7411\u670813\u65e5","format":false,"excerpt":"\u672c\u30d6\u30ed\u30b0\u30b7\u30ea\u30fc\u30ba\u3067\u306f\u3001\u6700\u9069\u306a\u30c9\u30e9\u30c3\u30b0\u30c7\u30ea\u30d0\u30ea\u30fc\u30b7\u30b9\u30c6\u30e0\u306e\u305f\u3081\u306e\u88fd\u5264\u958b\u767a\u306b\u304a\u3044\u3066\u6ce8\u76ee\u3059\u3079\u304d\u624b\u6cd5\u306e\u30db\u30c3\u30c8\u2026","rel":"","context":"\u5206\u6790\u30fb\u6e2c\u5b9a\u95a2\u9023","block_context":{"text":"\u5206\u6790\u30fb\u6e2c\u5b9a\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/analysis\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/10\/drug-formulation-hot-melt-extrusion-cad-26032_eyecatch.jpeg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/10\/drug-formulation-hot-melt-extrusion-cad-26032_eyecatch.jpeg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/10\/drug-formulation-hot-melt-extrusion-cad-26032_eyecatch.jpeg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/10\/drug-formulation-hot-melt-extrusion-cad-26032_eyecatch.jpeg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/10\/drug-formulation-hot-melt-extrusion-cad-26032_eyecatch.jpeg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/10\/drug-formulation-hot-melt-extrusion-cad-26032_eyecatch.jpeg?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":24695,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/environmental-analysis-laboratory-lpd-26008\/","url_meta":{"origin":409,"position":1},"title":"Orion Pro Star pH\uff0fISE\u30e1\u30fc\u30bf\u30fc\u3067\u5b9f\u73fe\u3059\u308b\u30a2\u30f3\u30e2\u30cb\u30a2\u30a4\u30aa\u30f3\u306e\u8fc5\u901f\u30fb\u9ad8\u7cbe\u5ea6\u6e2c\u5b9a\u5165\u9580","author":"LatB Staff","date":"2026\u5e742\u670818\u65e5","format":false,"excerpt":"\u6c34\u8cea\u30fb\u5ec3\u6c34\u51e6\u7406\u306e\u73fe\u5834\u3067\u306f\u3001\u30a2\u30f3\u30e2\u30cb\u30a2\u6fc3\u5ea6\u306e\u7ba1\u7406\u306f\u51e6\u7406\u30d7\u30ed\u30bb\u30b9\u3092\u6b63\u5e38\u306b\u4fdd\u3061\u3001\u6cd5\u898f\u5236\u306b\u9069\u5408\u3059\u308b\u305f\u3081\u306b\u6b20\u304b\u2026","rel":"","context":"\u5206\u6790\u30fb\u6e2c\u5b9a\u95a2\u9023","block_context":{"text":"\u5206\u6790\u30fb\u6e2c\u5b9a\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/analysis\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/01\/environmental-analysis-laboratory-lpd-26008_eyecatch_.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/01\/environmental-analysis-laboratory-lpd-26008_eyecatch_.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/01\/environmental-analysis-laboratory-lpd-26008_eyecatch_.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/01\/environmental-analysis-laboratory-lpd-26008_eyecatch_.jpg?resize=700%2C400&ssl=1 2x"},"classes":[]},{"id":24502,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/qubit-dna-bid-ts-mbr-25081\/","url_meta":{"origin":409,"position":2},"title":"Qubit \u30b7\u30ea\u30fc\u30ba Fluorometer\u306b\u3064\u3044\u3066","author":"LatB Staff","date":"2025\u5e7412\u670822\u65e5","format":false,"excerpt":"Invitrogen\u2122 Qubit\u2122\u30b7\u30ea\u30fc\u30ba Fluorometer\u306f\u3001\u5c02\u7528\u306e\u8a66\u85ac\u30ad\u30c3\u30c8\u3092\u7528\u3044\u308b\u3053\u3068\u2026","rel":"","context":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","block_context":{"text":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/mol-bio\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/12\/qubit-dna-bid-ts-mbr-25076_eyecatch.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/12\/qubit-dna-bid-ts-mbr-25076_eyecatch.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/12\/qubit-dna-bid-ts-mbr-25076_eyecatch.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/12\/qubit-dna-bid-ts-mbr-25076_eyecatch.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/12\/qubit-dna-bid-ts-mbr-25076_eyecatch.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/12\/qubit-dna-bid-ts-mbr-25076_eyecatch.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":24026,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/twin-screw-extrusion-extruder-cad-25071\/","url_meta":{"origin":409,"position":3},"title":"\u4e8c\u8ef8\u62bc\u51fa\u6a5f\u306e\u57fa\u790e\u2466\uff1a\u6750\u6599\u4f9b\u7d66\u306e\u30dd\u30a4\u30f3\u30c8","author":"LatB Staff","date":"2025\u5e7411\u670819\u65e5","format":false,"excerpt":"\u4e8c\u8ef8\u62bc\u51fa\u6a5f\u306e\u57fa\u790e\u30b7\u30ea\u30fc\u30ba\u3067\u306f\u88c5\u7f6e\u306e\u4ed5\u7d44\u307f\u3084\u7279\u9577\u3001\u30d1\u30e9\u30e1\u30fc\u30bf\u30fc\u8a2d\u5b9a\u3084\u305d\u306e\u610f\u5473\u3001\u5f8c\u5de5\u7a0b\u30aa\u30d7\u30b7\u30e7\u30f3\u3092\u7d44\u307f\u5408\u2026","rel":"","context":"\u305d\u306e\u4ed6","block_context":{"text":"\u305d\u306e\u4ed6","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/else\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/11\/twin-screw-extrusion-extruder-cad-25071_eyecatch.png?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/11\/twin-screw-extrusion-extruder-cad-25071_eyecatch.png?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/11\/twin-screw-extrusion-extruder-cad-25071_eyecatch.png?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/11\/twin-screw-extrusion-extruder-cad-25071_eyecatch.png?resize=700%2C400&ssl=1 2x"},"classes":[]},{"id":24408,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/elemental-analysis-case-introduction-cmd-25076\/","url_meta":{"origin":409,"position":4},"title":"LA-ICP-MS\u3067\u5b9f\u73fe\u3059\u308b\u7c89\u672b\u8a66\u6599\u306e\u8fc5\u901f\u30fb\u9ad8\u611f\u5ea6\u306a\u5143\u7d20\u5206\u6790","author":"LatB Staff","date":"2025\u5e7412\u670812\u65e5","format":false,"excerpt":"\u5316\u5b66\u54c1\u3084\u5de5\u696d\u6750\u6599\u306e\u539f\u6599\u3001\u304a\u3088\u3073\u4e8c\u6b21\u96fb\u6c60\u5411\u3051\u306e\u6a5f\u80fd\u6027\u6750\u6599\u306a\u3069\u3001\u7c89\u672b\u8a66\u6599\u3084\u30bb\u30e9\u30df\u30c3\u30af\u30b9\u6750\u6599\u4e2d\u306e\u5fae\u91cf\u5143\u7d20\u306e\u2026","rel":"","context":"\u5206\u6790\u30fb\u6e2c\u5b9a\u95a2\u9023","block_context":{"text":"\u5206\u6790\u30fb\u6e2c\u5b9a\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/analysis\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/12\/shutterstock_2249094135-scaled.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/12\/shutterstock_2249094135-scaled.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/12\/shutterstock_2249094135-scaled.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/12\/shutterstock_2249094135-scaled.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/12\/shutterstock_2249094135-scaled.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/12\/shutterstock_2249094135-scaled.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":25592,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/ion-chromatography-contaminant-analysis-cmd-26024\/","url_meta":{"origin":409,"position":5},"title":"\u5316\u7ca7\u54c1\u4e2d\u306ePFAS\u5206\u6790\u3068\u306f\uff1f\u7dcf\u6709\u6a5f\u30d5\u30c3\u7d20\uff08TOF\uff09\u6e2c\u5b9a\u306b\u3088\u308b\u30b9\u30af\u30ea\u30fc\u30cb\u30f3\u30b0\u3068\u898f\u5236\u5bfe\u5fdc","author":"LatB Staff","date":"2026\u5e749\u670810\u65e5","format":false,"excerpt":"PFAS\uff08\u6709\u6a5f\u30d5\u30c3\u7d20\u5316\u5408\u7269\uff09\u306f\u3001\u300c\u6c38\u9060\u306e\u5316\u5b66\u7269\u8cea\uff08Forever Chemicals\uff09\u300d\u3068\u3082\u547c\u3070\u308c\u3001\u2026","rel":"","context":"\u5206\u6790\u30fb\u6e2c\u5b9a\u95a2\u9023","block_context":{"text":"\u5206\u6790\u30fb\u6e2c\u5b9a\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/analysis\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/08\/ion-chromatography-contaminant-analysis-cmd-26024_eyecatch.png?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/08\/ion-chromatography-contaminant-analysis-cmd-26024_eyecatch.png?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/08\/ion-chromatography-contaminant-analysis-cmd-26024_eyecatch.png?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/08\/ion-chromatography-contaminant-analysis-cmd-26024_eyecatch.png?resize=700%2C400&ssl=1 2x"},"classes":[]}],"jetpack_sharing_enabled":true,"amp_enabled":true,"jetpack_featured_media_url":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/viscoelasticity-basic-title-1.jpg","_links":{"self":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/posts\/409","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/users\/988"}],"replies":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/comments?post=409"}],"version-history":[{"count":0,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/posts\/409\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/media\/2666"}],"wp:attachment":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/media?parent=409"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/categories?post=409"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/tags?post=409"},{"taxonomy":"division","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/division?post=409"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}