{"id":419,"date":"2016-06-08T00:00:00","date_gmt":"2016-06-08T00:00:00","guid":{"rendered":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/viscoelasticity-basic3\/"},"modified":"2026-08-03T14:41:07","modified_gmt":"2026-08-03T05:41:07","slug":"viscoelasticity-basic3","status":"publish","type":"post","link":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/viscoelasticity-basic3\/","title":{"rendered":"\u52d5\u7684\u7c98\u5f3e\u6027\u6e2c\u5b9a\u3067\u306e\u6e2c\u5b9a\u6761\u4ef6\u8a2d\u5b9a\u307e\u3068\u3081"},"content":{"rendered":"<h2>\u306f\u3058\u3081\u306b<\/h2>\n<p>\u524d\u3005\u56de\u3066\u3099\u306f\u3001\u7269\u6027\u3068\u3057\u3066\u306e\u7c98\u5f3e\u6027\u3068\u52d5\u7684\u7c98\u5f3e\u6027\u6e2c\u5b9a\u306e\u6982\u5ff5\u306b\u3064\u3044\u3066\u8aac\u660e\u3057\u3001\u524d\u56de\u306f\u3001\u5b9f\u969b\u306e\u30b5\u30f3\u30d5\u309a\u30eb\u6e2c\u5b9a\u30c6\u3099\u30fc\u30bf\u3092\u4f7f\u7528\u3057\u3066\u3001\u305d\u306e\u6982\u5ff5\u3092\u5177\u4f53\u7684\u306a\u5b9f\u4f8b\u3092\u3082\u3068\u306b\u89e3\u8aac\u3057\u307e\u3057\u305f\u3002\u4eca\u56de\u306f\u3001<strong><a href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/life-science\/lab-equipment\/rheometers-viscometers.html?CID=Social_LAB\" target=\"_blank\" rel=\"noopener noreferrer\">Thermo Scientific\u2122 HAAKE\u2122 \u30ec\u30aa\u30e1\u30fc\u30bf\u30fc<\/a>\u7528\u7d71\u5408\u30bd\u30d5\u30c8\u30a6\u30a7\u30a2 <a href=\"https:\/\/www.thermofisher.com\/order\/catalog\/product\/098-5057?CID=Social_LAB\" target=\"_blank\" rel=\"noopener noreferrer\">Thermo Scientific HAAKE Rheowin\u2122<\/a> \u306b\u3064\u3044\u3066\u3001\u5177\u4f53\u7684\u306a\u6e2c\u5b9a\u6761\u4ef6\u306e\u8a2d\u5b9a\u306e\u8003\u3048\u65b9\u3068\u30d5\u309a\u30ed\u30bb\u30b9\u3092\u89e3\u8aac\u3057\u307e\u3059\u3002<\/strong><\/p>\n<h2>\u52d5\u7684\u7c98\u5f3e\u6027\u8a66\u9a13\u306e\u57fa\u672c\u624b\u9806<\/h2>\n<p><strong>\u30ec\u30aa\u30e1\u30fc\u30bf\u30fc\u306b\u3088\u308b\u6e2c\u5b9a\u306f\u3001\u52d5\u7684\u7c98\u5f3e\u6027\u6e2c\u5b9a\u3068\u3044\u3046\u540d\u304b\u3099\u793a\u3059\u901a\u308a\u52d5\u7684\u306a\u6e2c\u5b9a\u3066\u3099\u3042\u308a\u3001\u7c98\u5f3e\u6027\u7387\u306e\u4f55\u3089\u304b\u306e\u56e0\u5b50\u3078\u306e\u4f9d\u5b58\u6027\u3092\u8abf\u3078\u3099\u308b\u3053\u3068\u3092\u76ee\u7684\u3068\u3057\u3066\u3044\u307e\u3059<\/strong>\u3002\u305d\u306e\u56e0\u5b50\u306f\u3001\u4e3b\u306b<strong>\u6e29\u5ea6\u3068\u901f\u5ea6(\u5468\u6ce2\u6570)<\/strong>\u3066\u3099\u3059\u3002<\/p>\n<h3>\u7dda\u5f62\u5f3e\u6027\u7387\u306e\u6e2c\u5b9a<\/h3>\n<p>\u69cb\u9020\u529b\u5b66\u3084\u6750\u6599\u529b\u5b66\u306a\u3068\u3099\u3066\u3099\u306f\u3001\u5f15\u3063\u5f35\u308a\u7834\u65ad\u8a66\u9a13\u3068\u3044\u3063\u305f\u3072\u3059\u3099\u307f\u3068\u5fdc\u529b\u306e\u95a2\u4fc2\u3092\u8abf\u3078\u3099\u308b\u6e2c\u5b9a\u3092\u884c\u3044\u3001\u56f31\u306e\u3088\u3046\u306aS(Stress)-S(Strain)\u66f2\u7dda\u306b\u3088\u308b\u8a55\u4fa1\u3092\u884c\u3044\u307e\u3059\u3002<\/p>\n<p><strong>S-S\u66f2\u7dda\u306b\u3088\u308b\u8a55\u4fa1\u306f\u307e\u3055\u306b\u5f3e\u6027\u7387\u306e\u8a66\u9a13\u3066\u3099\u3042\u308a\u3001\u30ec\u30aa\u30e1\u30fc\u30bf\u30fc\u306b\u3088\u308b\u6e2c\u5b9a\u3082\u5f3e\u6027\u7387\u8a66\u9a13\u3066\u3099\u3042\u308b\u305f\u3081\u3001\u307e\u3059\u3099\u3053\u308c\u306b\u6e96\u3057\u3099\u305f\u6e2c\u5b9a\u3092\u884c\u3046\u3053\u3068\u304b\u3099\u671b\u307e\u3057\u3044<\/strong>\u3068\u8a00\u3048\u307e\u3059\u3002<\/p>\n<div id=\"attachment_1232\" style=\"width: 418px\" class=\"wp-caption aligncenter\"><a href=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/viscoelasticity-basic3-fig1.jpg\" rel=\"attachment wp-att-1232\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-1232\" class=\"size-full wp-image-1232\" src=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/viscoelasticity-basic3-fig1.jpg\" alt=\"viscoelasticity-basic3-fig1\" width=\"408\" height=\"335\" \/><\/a><p id=\"caption-attachment-1232\" class=\"wp-caption-text\">\u56f31 S(Stress)-S(Strain)\u66f2\u7dda<\/p><\/div>\n<p>\u7dda\u5f62\u5f3e\u6027\u7387\u306e\u6e2c\u5b9a\u306b\u3088\u308a\u3001\u6750\u6599\u8a55\u4fa1\u3092\u884c\u3046\u4e0a\u3066\u3099\u57fa\u672c\u3068\u306a\u308b\u5f3e\u6027\u7387\u3084\u964d\u4f0f\u70b9\u306a\u3068\u3099\u306e\u60c5\u5831\u304b\u3099\u591a\u304f\u5f97\u3089\u308c\u307e\u3059\u3002\u307e\u305f\u3001<strong>\u3072\u3059\u3099\u307f\u3068\u5fdc\u529b\u306e\u95a2\u4fc2\u304b\u3099\u6b63\u6bd4\u4f8b\u306b\u3042\u308b\u7dda\u5f62\u5f3e\u6027\u57df\u3092\u77e5\u308b\u3053\u3068\u306f\u3001\u3053\u306e\u5148\u3066\u3099\u6e29\u5ea6\u3084\u5468\u6ce2\u6570\u4f9d\u5b58\u6027\u6e2c\u5b9a\u6642\u306e\u6761\u4ef6\u3092\u8a2d\u5b9a\u3059\u308b\u4e0a\u3066\u3099\u3082\u5927\u5909\u91cd\u8981<\/strong>\u3066\u3099\u3059\u3002\u56f32\u306b\u3001\u5c02\u7528\u30bd\u30d5\u30c8\u30a6\u30a7\u30a2HAAKE Rheowin\u3078\u306e\u6e2c\u5b9a\u8a2d\u5b9a\u6761\u4ef6\u306e\u5165\u529b\u6cd5\u3092\u793a\u3057\u307e\u3059\u3002<\/p>\n<div id=\"attachment_1233\" style=\"width: 525px\" class=\"wp-caption aligncenter\"><a href=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/viscoelasticity-basic3-fig2.jpg\" rel=\"attachment wp-att-1233\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-1233\" class=\"size-full wp-image-1233\" src=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/viscoelasticity-basic3-fig2.jpg\" alt=\"viscoelasticity-basic3-fig2\" width=\"515\" height=\"413\" \/><\/a><p id=\"caption-attachment-1233\" class=\"wp-caption-text\">\u56f32 \u5c02\u7528\u30bd\u30d5\u30c8\u30a6\u30a7\u30a2HAAKE Rheowin\u306b\u3088\u308b\u6e2c\u5b9a\u6761\u4ef6\u8a2d\u5b9a<\/p><\/div>\n<p>\u6761\u4ef6\u8a2d\u5b9a\u30a6\u30a3\u30f3\u30c8\u3099\u30a6\u306e\u4e2d\u3066\u3099\u3001CS\u30e2\u30fc\u30c8\u3099(\u5fdc\u529b\u5236\u5fa1)\u307e\u305f\u306fCD\u30e2\u30fc\u30c8\u3099(\u3072\u3059\u3099\u307f\u5236\u5fa1)\u3092\u9078\u5b9a\u3057\u307e\u3059\u3002\u4e0e\u3048\u305f\u5fdc\u529b\u306b\u3088\u308a\u767a\u751f\u3057\u305f\u3072\u3059\u3099\u307f\u91cf\u3092\u6e2c\u5b9a\u3059\u308b\u306e\u304b\u3099\u5fdc\u529b\u5236\u5fa1\u3066\u3099\u3042\u308a\u3001\u4e0e\u3048\u305f\u3072\u3059\u3099\u307f\u91cf\u306b\u3088\u308a\u767a\u751f\u3057\u305f\u5fdc\u529b\u3092\u6e2c\u5b9a\u3059\u308b\u306e\u304b\u3099\u3072\u3059\u3099\u307f\u5236\u5fa1\u3066\u3099\u3059\u3002<\/p>\n<p>CS\u30e2\u30fc\u30c8\u3099\u3066\u3099\u3042\u308c\u306f\u3099\u3001\u56de\u8ee2\u5b50\u306e\u632f\u308a\u5e45\u3092\u5909\u5316\u3055\u305b\u308b\u305f\u3081\u305b\u3093\u65ad\u5fdc\u529b(Pa)\u3092\u4efb\u610f\u306e\u7bc4\u56f2\u3066\u3099\u8a2d\u5b9a\u3057\u3001CD\u30e2\u30fc\u30c8\u3099\u3066\u3099\u3042\u308c\u306f\u3099\u3001\u3072\u3059\u3099\u307f\u91cf(%)\u3092\u4efb\u610f\u306e\u7bc4\u56f2\u3066\u3099\u8a2d\u5b9a\u3057\u3066\u5165\u529b\u3057\u307e\u3059\u3002\u5165\u529b\u3059\u3078\u3099\u304d\u958b\u59cb\u5024\u304b\u3099\u5206\u304b\u3089\u306a\u3044\u5834\u5408\u306f\u3001\u30e2\u30fc\u30bf\u30fc\u30c8\u30eb\u30af\u5024(CS\u30e2\u30fc\u30c8\u3099)\u307e\u305f\u306f\u89d2\u5ea6\u5024(CD\u30e2\u30fc\u30c8\u3099)\u306b\u3001\u88c5\u7f6e\u306e\u30b9\u30d8\u309a\u30c3\u30af\u4e0b\u9650\u5024\u3092\u5165\u529b\u3059\u308b\u3068\u3053\u308d\u304b\u3089\u59cb\u3081\u3066\u307f\u307e\u3059\u3002\u7d42\u4e86\u5024\u306b\u3064\u3044\u3066\u306f\u3001\u305f\u3068\u3048\u306f\u3099\u958b\u59cb\u5024\u306b\u5bfe\u3057\u30664\u6841\u30015\u6841\u4e0a\u306e\u5024\u3092\u5165\u308c\u3066\u307e\u3059\u3099\u6e2c\u5b9a\u3092\u884c\u3063\u3066\u307f\u307e\u3059\u3002\u632f\u308a\u304b\u3099\u5927\u304d\u904e\u304d\u3099\u308b(\u307e\u305f\u306f\u5c0f\u3055\u904e\u304d\u3099\u308b)\u5834\u5408\u306f\u6e2c\u5b9a\u3092\u4e2d\u6b62\u3057\u3001\u305d\u306e\u6642\u306e\u5fdc\u529b\u307e\u305f\u306f\u3072\u3059\u3099\u307f\u91cf\u3092\u3001\u6b21\u306e\u6e2c\u5b9a\u6761\u4ef6\u8a2d\u5b9a\u6642\u306b\u751f\u304b\u3059\u3088\u3046\u306b\u3057\u307e\u3059\u3002<\/p>\n<p>\u5468\u6ce2\u6570\u306b\u3064\u3044\u3066\u306f\u3001\u4f55\u3089\u304b\u610f\u5473\u306e\u3042\u308b\u5468\u671f\u3092\u7528\u3044\u308b\u5fc5\u8981\u304b\u3099\u306a\u3051\u308c\u306f\u3099\u30011 Hz\u3066\u3099\u306e\u6e2c\u5b9a\u3092\u304a\u52e7\u3081\u3057\u307e\u3059\u3002\u5831\u544a\u3055\u308c\u3066\u3044\u308b\u591a\u304f\u306e\u52d5\u7684\u7c98\u5f3e\u6027\u306e\u6e2c\u5b9a\u304b\u30991 Hz\u3066\u3099\u884c\u308f\u308c\u3066\u304a\u308a\u3001\u52d5\u7684\u7c98\u5f3e\u6027\u306f\u5468\u6ce2\u6570\u4f9d\u5b58\u6027\u3092\u6301\u3064\u305f\u3081\u3001\u5468\u6ce2\u6570\u3092\u5408\u308f\u305b\u3066\u304a\u304b\u306a\u3044\u3068\u30c6\u3099\u30fc\u30bf\u6bd4\u8f03\u304b\u3099\u96e3\u3057\u304f\u306a\u308b\u305f\u3081\u3066\u3099\u3059\u3002\u56f33\u306f\u3001\u7dda\u5f62\u5f3e\u6027\u7387\u306e\u6e2c\u5b9a\u30c6\u3099\u30fc\u30bf\u4f8b\u3066\u3099\u3059\u3002<\/p>\n<div id=\"attachment_1234\" style=\"width: 634px\" class=\"wp-caption aligncenter\"><a href=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/viscoelasticity-basic3-fig3.jpg\" rel=\"attachment wp-att-1234\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-1234\" class=\"size-full wp-image-1234\" src=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/viscoelasticity-basic3-fig3.jpg\" alt=\"viscoelasticity-basic3-fig3\" width=\"624\" height=\"289\" \/><\/a><p id=\"caption-attachment-1234\" class=\"wp-caption-text\">\u56f33 \u3072\u3059\u3099\u307f\u5909\u5316\u306b\u3088\u308b\u7dda\u5f62\u5f3e\u6027\u7387\u6e2c\u5b9a<\/p><\/div>\n<p>\u3053\u3053\u3066\u3099delta\u306f\u3072\u3059\u3099\u307f\u3068\u5fdc\u529b\u306e\u4e21\u6b63\u5f26\u6ce2\u306e\u4f4d\u76f8\u5dee\u3092\u8868\u3057\u3001G\u2019\u306f\u8caf\u8535\u5f3e\u6027(\u30cf\u3099\u30cd\u5f3e\u6027)\u3001G\u201d\u306f\u640d\u5931\u5f3e\u6027(\u7c98\u6027\u90e8\u5206)\u3092\u8868\u3057\u307e\u3059\u3002\u3053\u306e\u30af\u3099\u30e9\u30d5\u3066\u3099\u306f\u300110%\u672a\u6e80\u306e\u5c0f\u3055\u306a\u3072\u3059\u3099\u307f\u91cf\u306e\u3068\u3053\u308d\u3066\u3099\u306fG\u2019\u304b\u3099G\u201d\u3092\u4e0a\u56de\u3063\u3066\u304a\u308a\u3001\u56fa\u4f53\u7684\u306a\u72b6\u614b\u3066\u3099\u3042\u308b\u3053\u3068\u304b\u3099\u8aad\u307f\u53d6\u308c\u307e\u3059\u3002\u307e\u305f\u3001\u3072\u3059\u3099\u307f\u91cf\u304b\u309930%\u7a0b\u5ea6\u306e\u3068\u3053\u308d\u3066\u3099G\u2019\u3068G\u201d\u306e\u66f2\u7dda\u304b\u3099\u4ea4\u5dee\u3057\u3001delta\u304b\u309945\u00b0\u3092\u793a\u3057\u3066\u3044\u308b\u3053\u3068\u304b\u3089\u3001\u3053\u3053\u304b\u3099\u5f3e\u6027\u3068\u5851\u6027\u306e\u9077\u79fb\u70b9\u3066\u3099\u3042\u308b\u3053\u3068\u304b\u3099\u8aad\u307f\u53d6\u308c\u307e\u3059\u3002<\/p>\n<p>\u306a\u304a\u3001\u3053\u306e\u30af\u3099\u30e9\u30d5\u306e\u7e26\u8ef8\u3092\u56f34\u306e\u3088\u3046\u306b\u305b\u3093\u65ad\u5fdc\u529b\u306b\u5909\u3048\u308b\u3068\u3001\u56f31\u306eS-S\u66f2\u7dda\u3068\u985e\u4f3c\u3057\u305f\u66f2\u7dda\u304b\u3099\u8868\u793a\u3055\u308c\u307e\u3059\u3002<\/p>\n<div id=\"attachment_1235\" style=\"width: 612px\" class=\"wp-caption aligncenter\"><a href=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/viscoelasticity-basic3-fig4.jpg\" rel=\"attachment wp-att-1235\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-1235\" class=\"size-full wp-image-1235\" src=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/viscoelasticity-basic3-fig4.jpg\" alt=\"viscoelasticity-basic3-fig4\" width=\"602\" height=\"313\" \/><\/a><p id=\"caption-attachment-1235\" class=\"wp-caption-text\">\u56f34 \u52d5\u7684\u7c98\u5f3e\u6027\u6e2c\u5b9a\u306b\u3088\u308bS-S\u66f2\u7dda<\/p><\/div>\n<p>\u3072\u3059\u3099\u307f\u91cf\u3068\u305b\u3093\u65ad\u5fdc\u529b\u304b\u3099\u6b63\u6bd4\u4f8b\u306e\u95a2\u4fc2\u306b\u306a\u3063\u3066\u3044\u308b\u7bc4\u56f2\u304b\u3099\u7dda\u5f62\u5f3e\u6027\u9818\u57df\u3066\u3099\u3042\u308a\u3001\u56f33\u306b\u304a\u3044\u3066\u306f\u3001G\u2019\u3068G\u201d\u306e\u4e21\u66f2\u7dda\u304b\u3099\u5e73\u884c\u3066\u3099\u5e73\u5766\u3068\u306a\u3063\u3066\u3044\u308b\u9818\u57df\u304b\u3099\u305d\u308c\u306b\u5f53\u305f\u308a\u307e\u3059\u3002<\/p>\n<h3>\u5468\u6ce2\u6570\u4f9d\u5b58\u6027\u6e2c\u5b9a<\/h3>\n<p>\u3042\u308b\u4e00\u5b9a\u306e\u3072\u3059\u3099\u307f\u8a2d\u5b9a\u306b\u3088\u308a\u3001\u632f\u52d5\u306e\u5468\u6ce2\u6570\u3092\u5909\u5316\u3055\u305b\u305f\u5834\u5408\u306e\u5f3e\u6027\u7387\u306e\u5909\u5316\u3092\u6e2c\u5b9a\u3057\u3066\u307f\u307e\u3059\u3002<\/p>\n<p>\u4e00\u5b9a\u306e\u3072\u3059\u3099\u307f\u8a2d\u5b9a\u3092\u884c\u3046\u306b\u3042\u305f\u308a\u3001\u307e\u3059\u3099\u7dda\u5f62\u5f3e\u6027\u7387\u6e2c\u5b9a\u306e\u7d50\u679c(\u56f33\u307e\u305f\u306f4)\u3092\u53c2\u7167\u3057\u3066\u3001\u7dda\u5f62\u9818\u57df\u5185\u306e\u3072\u3059\u3099\u307f\u91cf\u307e\u305f\u306f\u305b\u3093\u65ad\u5fdc\u529b\u306e\u5024\u3092\u6c7a\u5b9a\u3057\u307e\u3059\u3002<\/p>\n<p>\u7279\u5225\u306a\u7406\u7531\u304b\u3099\u306a\u3051\u308c\u306f\u3099\u3001CD\u30e2\u30fc\u30c8\u3099\u306b\u3088\u308b\u8a2d\u5b9a\u3092\u304a\u52e7\u3081\u3057\u307e\u3059\u3002\u56f35\u3066\u3099\u793a\u3059\u3088\u3046\u306b\u3001\u7dda\u5f62\u9818\u57df\u3092\u30ab\u30cf\u3099\u30fc\u3059\u308b\u305b\u3093\u65ad\u5fdc\u529b\u306e\u7bc4\u56f2\u306e\u5468\u6ce2\u6570\u3078\u306e\u4f9d\u5b58\u6027\u306f\u3001\u3072\u3059\u3099\u307f\u91cf\u3078\u306e\u4f9d\u5b58\u6027\u3088\u308a\u3082\u5927\u304d\u304f\u306a\u308b\u5834\u5408\u304b\u3099\u591a\u3044\u305f\u3081\u3066\u3099\u3059\u3002<\/p>\n<div id=\"attachment_1236\" style=\"width: 472px\" class=\"wp-caption aligncenter\"><a href=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/viscoelasticity-basic3-fig5.jpg\" rel=\"attachment wp-att-1236\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-1236\" class=\"size-full wp-image-1236\" src=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/viscoelasticity-basic3-fig5.jpg\" alt=\"viscoelasticity-basic3-fig5\" width=\"462\" height=\"325\" \/><\/a><p id=\"caption-attachment-1236\" class=\"wp-caption-text\">\u56f35 \u305b\u3093\u65ad\u5fdc\u529b\u306e\u5468\u6ce2\u6570\u4f9d\u5b58\u6027(\u6a2a\u8ef8: \u305b\u3093\u65ad\u5fdc\u529b\u3001\u7e26\u8ef8: G\u2019)<\/p><\/div>\n<p>\u5177\u4f53\u7684\u306b\u306f\u3001\u56f33\u307e\u305f\u306f4\u306e\u30af\u3099\u30e9\u30d5\u306e\u7dda\u5f62\u9818\u57df\u306b\u3042\u308b\u3072\u3059\u3099\u307f\u91cf\u306e\u7bc4\u56f2\u3066\u3099\u3001\u964d\u4f0f\u70b9\u5bc4\u308a\u306e\u5024\u3092\u7528\u3044\u307e\u3059\u3002\u3053\u308c\u306f\u3001\u4f4e\u5468\u6ce2\u306b\u306a\u308b\u307b\u3068\u3099\u5f3e\u6027\u7387\u306f\u5c0f\u3055\u304f\u306a\u308b\u305f\u3081(\u56f35)\u3001\u4f4e\u5468\u6ce2\u5074\u306e\u6e2c\u5b9a\u306e\u969b\u306b\u3001\u88c5\u7f6e\u306e\u30e2\u30fc\u30bf\u30fc\u30c8\u30eb\u30af\u4e0b\u9650\u5024\u3092\u4e0b\u56de\u3089\u306a\u3044\u3088\u3046\u306b\u3059\u308b\u305f\u3081\u3066\u3099\u3059\u3002\u56f36\u306b\u3001\u3072\u3059\u3099\u307f\u91cf2%\u8a2d\u5b9a\u306b\u3088\u308a\u6e2c\u5b9a\u3057\u305f\u7d50\u679c\u3092\u793a\u3057\u307e\u3059\u3002<\/p>\n<div id=\"attachment_1237\" style=\"width: 633px\" class=\"wp-caption aligncenter\"><a href=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/viscoelasticity-basic3-fig6.jpg\" rel=\"attachment wp-att-1237\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-1237\" class=\"size-full wp-image-1237\" src=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/viscoelasticity-basic3-fig6.jpg\" alt=\"viscoelasticity-basic3-fig6\" width=\"623\" height=\"294\" \/><\/a><p id=\"caption-attachment-1237\" class=\"wp-caption-text\">\u56f36 \u5468\u6ce2\u6570\u4f9d\u5b58\u6027\u6e2c\u5b9a<\/p><\/div>\n<h3>\u6e29\u5ea6\u4f9d\u5b58\u6027\u6e2c\u5b9a<\/h3>\n<p>\u6e29\u5ea6\u4f9d\u5b58\u6027\u306e\u6e2c\u5b9a\u3066\u3099\u306f\u3001\u8a66\u6599\u304b\u3099\u786c\u5316\u72b6\u614b\u3068\u6eb6\u878d\u72b6\u614b\u3092\u9077\u79fb\u3059\u308b\u306a\u3068\u3099\u6e2c\u5b9a\u306e\u7d42\u59cb\u3066\u3099\u5f3e\u6027\u7387\u304b\u3099\u5927\u304d\u304f\u5909\u5316\u3059\u308b\u5834\u5408\u304b\u3099\u591a\u304f\u3001\u6761\u4ef6\u8a2d\u5b9a\u3066\u3099\u3057\u306f\u3099\u3057\u306f\u3099\u6e2c\u5b9a\u8005\u3092\u60a9\u307e\u305b\u307e\u3059\u3002<\/p>\n<p>\u6e29\u5ea6\u4f9d\u5b58\u6027\u6e2c\u5b9a\u3066\u3099\u306f\u3001\u3042\u308b\u4e00\u5b9a\u306e\u3072\u3059\u3099\u307f\u8a2d\u5b9a\u306b\u3088\u308a\u3001\u6e29\u5ea6\u5909\u5316\u306b\u4f34\u3046\u5f3e\u6027\u7387\u306e\u5909\u5316\u3092\u6e2c\u5b9a\u3057\u307e\u3059\u3002\u305d\u306e\u305f\u3081\u3001\u7406\u60f3\u7684\u306b\u306f\u56f37\u306e\u3088\u3046\u306b\u3001<strong>\u6700\u4f4e\u6e29\u5ea6\u3068\u6700\u9ad8\u6e29\u5ea6(\u6700\u4f4e\u7c98\u5f3e\u6027\u306e\u72b6\u614b\u3068\u6700\u9ad8\u7c98\u5f3e\u6027\u306e\u72b6\u614b)\u306b\u304a\u3051\u308b\u7dda\u5f62\u5f3e\u6027\u7387\u3092\u78ba\u8a8d\u3057\u3001\u6e2c\u5b9a\u6e29\u5ea6\u306e\u4e21\u7aef\u3092\u6e80\u305f\u3059\u6e2c\u5b9a\u6761\u4ef6\u3092\u78ba\u8a8d\u3057\u3066\u304a\u304f\u3053\u3068\u304b\u3099\u671b\u307e\u3057\u3044<\/strong>\u3068\u8a00\u3048\u307e\u3059\u3002<\/p>\n<div id=\"attachment_1238\" style=\"width: 616px\" class=\"wp-caption aligncenter\"><a href=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/viscoelasticity-basic3-fig7.jpg\" rel=\"attachment wp-att-1238\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-1238\" class=\"size-full wp-image-1238\" src=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/viscoelasticity-basic3-fig7.jpg\" alt=\"viscoelasticity-basic3-fig7\" width=\"606\" height=\"288\" \/><\/a><p id=\"caption-attachment-1238\" class=\"wp-caption-text\">\u56f37 \u7dda\u5f62\u5f3e\u6027\u7387\u6e2c\u5b9a\u306b\u3088\u308b\u7dda\u5f62\u57df\u306e\u7279\u5b9a(20\u3001110\u00b0C)<\/p><\/div>\n<p>\u5468\u6ce2\u6570\u4f9d\u5b58\u6027\u6e2c\u5b9a\u3068\u540c\u69d8\u3001\u7279\u5225\u306a\u7406\u7531\u304b\u3099\u306a\u3051\u308c\u306f\u3099 CD\u30e2\u30fc\u30c8\u3099\u306b\u3088\u308b\u8a2d\u5b9a\u3092\u304a\u52e7\u3081\u3057\u307e\u3059\u3002\u3053\u308c\u306f\u3001\u7dda\u5f62\u9818\u57df\u3092\u30ab\u30cf\u3099\u30fc\u3059\u308b\u305b\u3093\u65ad\u5fdc\u529b\u306e\u7bc4\u56f2\u306e\u6e29\u5ea6\u3078\u306e\u4f9d\u5b58\u6027\u306f\u3001\u3072\u3059\u3099\u307f\u91cf\u3078\u306e\u4f9d\u5b58\u6027\u3088\u308a\u3082\u5927\u304d\u3044\u50be\u5411\u304b\u3099\u3042\u308b\u305f\u3081\u3066\u3099\u3059(\u56f37)\u3002\u5b9f\u969b\u306b\u306f\u3001\u9ad8\u6e29\u5074\u3068\u4f4e\u6e29\u5074\u306e\u305d\u308c\u305d\u3099\u308c\u3066\u3099\u7dda\u5f62\u5f3e\u6027\u7387\u6e2c\u5b9a\u3092\u884c\u3046\u3053\u3068\u306f\u624b\u9593\u3066\u3099\u3042\u308b\u305f\u3081\u3001\u4f4e\u6e29(\u9ad8\u7c98\u5f3e\u6027\u5074)\u306e\u307f\u3066\u3099\u7dda\u5f62\u57df\u306e\u78ba\u8a8d\u3092\u884c\u3063\u305f\u306e\u3066\u3099\u3042\u308c\u306f\u3099\u964d\u4f0f\u70b9\u5bc4\u308a\u306e\u3072\u3059\u3099\u307f\u91cf\u3092\u7528\u3044\u3001\u9ad8\u6e29(\u4f4e\u7c98\u5f3e\u6027\u5074)\u306e\u307f\u3066\u3099\u7dda\u5f62\u57df\u306e\u78ba\u8a8d\u3092\u884c\u3063\u305f\u306e\u3066\u3099\u3042\u308c\u306f\u3099\u4e0b\u9650\u306b\u8fd1\u3044\u3072\u3059\u3099\u307f\u91cf\u3092\u7528\u3044\u308b\u3088\u3046\u306b\u3057\u307e\u3059\u3002\u56f38\u306f\u3001\u56f37\u3092\u53c2\u8003\u306b\u3001\u3072\u3059\u3099\u307f\u91cf2%\u8a2d\u5b9a\u306b\u3088\u308a\u6e29\u5ea6\u4f9d\u5b58\u6027\u6e2c\u5b9a\u3092\u884c\u3063\u305f\u7d50\u679c\u3066\u3099\u3059\u3002<\/p>\n<div id=\"attachment_1239\" style=\"width: 612px\" class=\"wp-caption aligncenter\"><a href=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/viscoelasticity-basic3-fig8.jpg\" rel=\"attachment wp-att-1239\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-1239\" class=\"size-full wp-image-1239\" src=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/viscoelasticity-basic3-fig8.jpg\" alt=\"viscoelasticity-basic3-fig8\" width=\"602\" height=\"286\" \/><\/a><p id=\"caption-attachment-1239\" class=\"wp-caption-text\">\u56f38 \u6e29\u5ea6\u4f9d\u5b58\u6027\u6e2c\u5b9a<\/p><\/div>\n<h1>\u30ec\u30aa\u30e1\u30fc\u30bf\u30fc\u3084\u7c98\u5ea6\u8a08\u88fd\u54c1\u306b\u95a2\u3059\u308b\u304a\u554f\u3044\u5408\u308f\u305b<\/h1>\n<p>\u3044\u304b\u304c\u3060\u3063\u305f\u3067\u3057\u3087\u3046\u304b\uff1f\u3000\u8a18\u4e8b\u3066\u3099\u30ab\u30cf\u3099\u30fc\u3066\u3099\u304d\u306a\u304b\u3063\u305f\u9ad8\u5ea6\u306a\u7528\u9014\u306b\u3064\u3044\u3066\u306f\u3001\u5f0a\u793e\u306e\u6280\u8853\u30c6\u30af\u30cb\u30ab\u30eb\u30b5\u30db\u309a\u30fc\u30c8\u307e\u3066\u3099\u3053\u3099\u76f8\u8ac7\u304f\u305f\u3099\u3055\u3044\uff08\u6700\u4e0b\u90e8\u30d5\u30a9\u30fc\u30e0\u53c2\u7167\uff09\u3002<\/p>\n<p>\u305d\u306e\u4ed6\u3001\u30ec\u30aa\u30e1\u30fc\u30bf\u30fc\u3084\u7c98\u5ea6\u8a08\u88fd\u54c1\u306b\u3064\u3044\u3066<\/p>\n<ul style=\"list-style-type: disc\">\n<li><strong>\u30c7\u30e2<\/strong>\u3092\u4f9d\u983c\u3057\u305f\u3044<\/li>\n<li><strong>\u898b\u7a4d\u3082\u308a<\/strong>\u304c\u307b\u3057\u3044<\/li>\n<li>\u305d\u306e\u4ed6\uff08<strong>\u8cc7\u6599\u304c\u307b\u3057\u3044\u3001\u8a71\u3092\u805e\u3044\u3066\u307f\u305f\u3044\u3001\u62c5\u5f53\u8005\u304b\u3089\u9023\u7d61\u304c\u307b\u3057\u3044<\/strong> \u7b49\uff09<\/li>\n<\/ul>\n<p>\u7b49\u306e\u3054\u8981\u671b\u304c\u3042\u308a\u307e\u3057\u305f\u3089\u3001\u4e0b\u8a18\u30dc\u30bf\u30f3\u3088\u308a\u304a\u6c17\u8efd\u306b\u3054\u76f8\u8ac7\u304f\u3060\u3055\u3044\u3002<\/p>\n<p><a class=\"btn btn-red ext-link wpel-icon-right\" href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/life-science\/lab-equipment\/rheometers-viscometers\/rheometers-inquiry.html?CID=Social_LAB\" target=\"_blank\" rel=\"external noopener noreferrer\">\u30ec\u30aa\u30e1\u30fc\u30bf\u30fc\u3084\u7c98\u5ea6\u8a08\u88fd\u54c1\u306b\u95a2\u3059\u308b\u304a\u554f\u3044\u5408\u308f\u305b\u306f\u3053\u3061\u3089<\/a><\/p>\n<p>\u7814\u7a76\u7528\u306b\u306e\u307f\u4f7f\u7528\u3067\u304d\u307e\u3059\u3002\u8a3a\u65ad\u7528\u306b\u306f\u4f7f\u7528\u3044\u305f\u3060\u3051\u307e\u305b\u3093\u3002<\/p>\n","protected":false},"excerpt":{"rendered":"<p>\u4eca\u56de\u306f\u3001Thermo Scientific&#x2122; HAAKE&#x2122; \u30ec\u30aa\u30e1\u30fc\u30bf\u30fc\u7528\u7d71\u5408\u30bd\u30d5\u30c8\u30a6\u30a7\u30a2 Thermo Scientific HAAKE Rheowin&#x2122; \u306b\u3064\u3044\u3066\u3001\u5177\u4f53\u7684\u306a\u6e2c\u5b9a\u6761\u4ef6\u306e\u8a2d\u5b9a\u306e\u8003\u3048\u65b9\u3068\u30d5\u309a\u30ed\u30bb\u30b9\u3092\u89e3\u8aac\u3057\u307e\u3059\u3002<\/p>\n","protected":false},"author":988,"featured_media":2686,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_monsterinsights_skip_tracking":false,"_genesis_hide_title":false,"_genesis_hide_breadcrumbs":false,"_genesis_hide_singular_image":false,"_genesis_hide_footer_widgets":false,"_genesis_custom_body_class":"","_genesis_custom_post_class":"","_genesis_layout":"","_jetpack_newsletter_access":"","_jetpack_dont_email_post_to_subs":false,"_jetpack_newsletter_tier_id":0,"_jetpack_memberships_contains_paywalled_content":false,"_jetpack_feature_clip_id":0,"_jetpack_memberships_contains_paid_content":false,"footnotes":"","jetpack_post_was_ever_published":false},"categories":[157],"tags":[54],"division":[],"class_list":["post-419","post","type-post","status-publish","format-standard","has-post-thumbnail","category-analysis","tag-dma","entry"],"_selected_authors":[],"_selected_reviewers":[],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v27.8 (Yoast SEO v27.8) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>\u52d5\u7684\u7c98\u5f3e\u6027\u6e2c\u5b9a\u3067\u306e\u6e2c\u5b9a\u6761\u4ef6\u8a2d\u5b9a\u307e\u3068\u3081 - Learning at the Bench<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/viscoelasticity-basic3\/\" \/>\n<meta property=\"og:locale\" content=\"ja_JP\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"\u52d5\u7684\u7c98\u5f3e\u6027\u6e2c\u5b9a\u3067\u306e\u6e2c\u5b9a\u6761\u4ef6\u8a2d\u5b9a\u307e\u3068\u3081\" \/>\n<meta property=\"og:description\" content=\"\u4eca\u56de\u306f\u3001Thermo Scientific&#x2122; HAAKE&#x2122; \u30ec\u30aa\u30e1\u30fc\u30bf\u30fc\u7528\u7d71\u5408\u30bd\u30d5\u30c8\u30a6\u30a7\u30a2 Thermo Scientific HAAKE Rheowin&#x2122; \u306b\u3064\u3044\u3066\u3001\u5177\u4f53\u7684\u306a\u6e2c\u5b9a\u6761\u4ef6\u306e\u8a2d\u5b9a\u306e\u8003\u3048\u65b9\u3068\u30d5\u309a\u30ed\u30bb\u30b9\u3092\u89e3\u8aac\u3057\u307e\u3059\u3002\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/viscoelasticity-basic3\/\" \/>\n<meta property=\"og:site_name\" content=\"Learning at the Bench\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/ThermoFisherJapan\" \/>\n<meta property=\"article:published_time\" content=\"2016-06-08T00:00:00+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2026-08-03T05:41:07+00:00\" \/>\n<meta property=\"og:image\" content=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/viscoelasticity-basic-title-2.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"1200\" \/>\n\t<meta property=\"og:image:height\" content=\"630\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"LATB Staff\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:creator\" content=\"@ThermoFisherJP\" \/>\n<meta name=\"twitter:site\" content=\"@ThermoFisherJP\" \/>\n<meta name=\"twitter:label1\" content=\"\u57f7\u7b46\u8005\" \/>\n\t<meta name=\"twitter:data1\" content=\"LATB Staff\" \/>\n\t<meta name=\"twitter:label2\" content=\"\u63a8\u5b9a\u8aad\u307f\u53d6\u308a\u6642\u9593\" \/>\n\t<meta name=\"twitter:data2\" content=\"11\u5206\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/viscoelasticity-basic3\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/viscoelasticity-basic3\\\/\"},\"author\":{\"name\":\"LATB Staff\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#\\\/schema\\\/person\\\/00a095a01d54afcdf9457465feb04f7d\"},\"headline\":\"\u52d5\u7684\u7c98\u5f3e\u6027\u6e2c\u5b9a\u3067\u306e\u6e2c\u5b9a\u6761\u4ef6\u8a2d\u5b9a\u307e\u3068\u3081\",\"datePublished\":\"2016-06-08T00:00:00+00:00\",\"dateModified\":\"2026-08-03T05:41:07+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/viscoelasticity-basic3\\\/\"},\"wordCount\":101,\"commentCount\":0,\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/viscoelasticity-basic3\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2019\\\/07\\\/viscoelasticity-basic-title-2.jpg\",\"keywords\":[\"\u52d5\u7684\u7c98\u5f3e\u6027\u6e2c\u5b9a\"],\"articleSection\":[\"\u5206\u6790\u30fb\u6e2c\u5b9a\u95a2\u9023\"],\"inLanguage\":\"ja\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/viscoelasticity-basic3\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/viscoelasticity-basic3\\\/\",\"url\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/viscoelasticity-basic3\\\/\",\"name\":\"\u52d5\u7684\u7c98\u5f3e\u6027\u6e2c\u5b9a\u3067\u306e\u6e2c\u5b9a\u6761\u4ef6\u8a2d\u5b9a\u307e\u3068\u3081 - Learning at the Bench\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/viscoelasticity-basic3\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/viscoelasticity-basic3\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2019\\\/07\\\/viscoelasticity-basic-title-2.jpg\",\"datePublished\":\"2016-06-08T00:00:00+00:00\",\"dateModified\":\"2026-08-03T05:41:07+00:00\",\"author\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#\\\/schema\\\/person\\\/00a095a01d54afcdf9457465feb04f7d\"},\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/viscoelasticity-basic3\\\/#breadcrumb\"},\"inLanguage\":\"ja\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/viscoelasticity-basic3\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"ja\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/viscoelasticity-basic3\\\/#primaryimage\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2019\\\/07\\\/viscoelasticity-basic-title-2.jpg\",\"contentUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2019\\\/07\\\/viscoelasticity-basic-title-2.jpg\",\"width\":1200,\"height\":630,\"caption\":\"viscoelasticity-basic-title\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/viscoelasticity-basic3\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"\u52d5\u7684\u7c98\u5f3e\u6027\u6e2c\u5b9a\u3067\u306e\u6e2c\u5b9a\u6761\u4ef6\u8a2d\u5b9a\u307e\u3068\u3081\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#website\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/\",\"name\":\"Learning at the Bench\",\"description\":\"\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"ja\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#\\\/schema\\\/person\\\/00a095a01d54afcdf9457465feb04f7d\",\"name\":\"LATB Staff\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"ja\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/8803277856c8b753feb4217dff0f9953327452df1a615c3c88b2f9864efb2ddd?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/8803277856c8b753feb4217dff0f9953327452df1a615c3c88b2f9864efb2ddd?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/8803277856c8b753feb4217dff0f9953327452df1a615c3c88b2f9864efb2ddd?s=96&d=mm&r=g\",\"caption\":\"LATB Staff\"},\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/author\\\/latbstaff\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"\u52d5\u7684\u7c98\u5f3e\u6027\u6e2c\u5b9a\u3067\u306e\u6e2c\u5b9a\u6761\u4ef6\u8a2d\u5b9a\u307e\u3068\u3081 - Learning at the Bench","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/viscoelasticity-basic3\/","og_locale":"ja_JP","og_type":"article","og_title":"\u52d5\u7684\u7c98\u5f3e\u6027\u6e2c\u5b9a\u3067\u306e\u6e2c\u5b9a\u6761\u4ef6\u8a2d\u5b9a\u307e\u3068\u3081","og_description":"\u4eca\u56de\u306f\u3001Thermo Scientific&#x2122; HAAKE&#x2122; \u30ec\u30aa\u30e1\u30fc\u30bf\u30fc\u7528\u7d71\u5408\u30bd\u30d5\u30c8\u30a6\u30a7\u30a2 Thermo Scientific HAAKE Rheowin&#x2122; \u306b\u3064\u3044\u3066\u3001\u5177\u4f53\u7684\u306a\u6e2c\u5b9a\u6761\u4ef6\u306e\u8a2d\u5b9a\u306e\u8003\u3048\u65b9\u3068\u30d5\u309a\u30ed\u30bb\u30b9\u3092\u89e3\u8aac\u3057\u307e\u3059\u3002","og_url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/viscoelasticity-basic3\/","og_site_name":"Learning at the Bench","article_publisher":"https:\/\/www.facebook.com\/ThermoFisherJapan","article_published_time":"2016-06-08T00:00:00+00:00","article_modified_time":"2026-08-03T05:41:07+00:00","og_image":[{"width":1200,"height":630,"url":"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/viscoelasticity-basic-title-2.jpg","type":"image\/jpeg"}],"author":"LATB Staff","twitter_card":"summary_large_image","twitter_creator":"@ThermoFisherJP","twitter_site":"@ThermoFisherJP","twitter_misc":{"\u57f7\u7b46\u8005":"LATB Staff","\u63a8\u5b9a\u8aad\u307f\u53d6\u308a\u6642\u9593":"11\u5206"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/viscoelasticity-basic3\/#article","isPartOf":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/viscoelasticity-basic3\/"},"author":{"name":"LATB Staff","@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#\/schema\/person\/00a095a01d54afcdf9457465feb04f7d"},"headline":"\u52d5\u7684\u7c98\u5f3e\u6027\u6e2c\u5b9a\u3067\u306e\u6e2c\u5b9a\u6761\u4ef6\u8a2d\u5b9a\u307e\u3068\u3081","datePublished":"2016-06-08T00:00:00+00:00","dateModified":"2026-08-03T05:41:07+00:00","mainEntityOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/viscoelasticity-basic3\/"},"wordCount":101,"commentCount":0,"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/viscoelasticity-basic3\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/viscoelasticity-basic-title-2.jpg","keywords":["\u52d5\u7684\u7c98\u5f3e\u6027\u6e2c\u5b9a"],"articleSection":["\u5206\u6790\u30fb\u6e2c\u5b9a\u95a2\u9023"],"inLanguage":"ja","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/viscoelasticity-basic3\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/viscoelasticity-basic3\/","url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/viscoelasticity-basic3\/","name":"\u52d5\u7684\u7c98\u5f3e\u6027\u6e2c\u5b9a\u3067\u306e\u6e2c\u5b9a\u6761\u4ef6\u8a2d\u5b9a\u307e\u3068\u3081 - Learning at the Bench","isPartOf":{"@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/viscoelasticity-basic3\/#primaryimage"},"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/viscoelasticity-basic3\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/viscoelasticity-basic-title-2.jpg","datePublished":"2016-06-08T00:00:00+00:00","dateModified":"2026-08-03T05:41:07+00:00","author":{"@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#\/schema\/person\/00a095a01d54afcdf9457465feb04f7d"},"breadcrumb":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/viscoelasticity-basic3\/#breadcrumb"},"inLanguage":"ja","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/viscoelasticity-basic3\/"]}]},{"@type":"ImageObject","inLanguage":"ja","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/viscoelasticity-basic3\/#primaryimage","url":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/viscoelasticity-basic-title-2.jpg","contentUrl":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/viscoelasticity-basic-title-2.jpg","width":1200,"height":630,"caption":"viscoelasticity-basic-title"},{"@type":"BreadcrumbList","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/viscoelasticity-basic3\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/"},{"@type":"ListItem","position":2,"name":"\u52d5\u7684\u7c98\u5f3e\u6027\u6e2c\u5b9a\u3067\u306e\u6e2c\u5b9a\u6761\u4ef6\u8a2d\u5b9a\u307e\u3068\u3081"}]},{"@type":"WebSite","@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#website","url":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/","name":"Learning at the Bench","description":"","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"ja"},{"@type":"Person","@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#\/schema\/person\/00a095a01d54afcdf9457465feb04f7d","name":"LATB Staff","image":{"@type":"ImageObject","inLanguage":"ja","@id":"https:\/\/secure.gravatar.com\/avatar\/8803277856c8b753feb4217dff0f9953327452df1a615c3c88b2f9864efb2ddd?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/8803277856c8b753feb4217dff0f9953327452df1a615c3c88b2f9864efb2ddd?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/8803277856c8b753feb4217dff0f9953327452df1a615c3c88b2f9864efb2ddd?s=96&d=mm&r=g","caption":"LATB Staff"},"url":"https:\/\/admin.acceleratingscience.com\/author\/latbstaff\/"}]}},"taxonomy_info":{"category":[{"value":157,"label":"\u5206\u6790\u30fb\u6e2c\u5b9a\u95a2\u9023"}],"post_tag":[{"value":54,"label":"\u52d5\u7684\u7c98\u5f3e\u6027\u6e2c\u5b9a"}]},"featured_image_src_large":["https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/viscoelasticity-basic-title-2-1024x538.jpg",760,399,true],"author_info":{"display_name":"LATB Staff","author_link":"https:\/\/admin.acceleratingscience.com\/author\/latbstaff\/"},"comment_info":0,"category_info":[{"term_id":157,"name":"\u5206\u6790\u30fb\u6e2c\u5b9a\u95a2\u9023","slug":"analysis","term_group":0,"term_taxonomy_id":157,"taxonomy":"category","description":"","parent":0,"count":106,"filter":"raw","meta":[],"cat_ID":157,"category_count":106,"category_description":"","cat_name":"\u5206\u6790\u30fb\u6e2c\u5b9a\u95a2\u9023","category_nicename":"analysis","category_parent":0}],"tag_info":[{"term_id":54,"name":"\u52d5\u7684\u7c98\u5f3e\u6027\u6e2c\u5b9a","slug":"dma","term_group":0,"term_taxonomy_id":54,"taxonomy":"post_tag","description":"","parent":0,"count":3,"filter":"raw","meta":[]}],"jetpack-related-posts":[{"id":24695,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/environmental-analysis-laboratory-lpd-26008\/","url_meta":{"origin":419,"position":0},"title":"Orion Pro Star pH\uff0fISE\u30e1\u30fc\u30bf\u30fc\u3067\u5b9f\u73fe\u3059\u308b\u30a2\u30f3\u30e2\u30cb\u30a2\u30a4\u30aa\u30f3\u306e\u8fc5\u901f\u30fb\u9ad8\u7cbe\u5ea6\u6e2c\u5b9a\u5165\u9580","author":"LatB Staff","date":"2026\u5e742\u670818\u65e5","format":false,"excerpt":"\u6c34\u8cea\u30fb\u5ec3\u6c34\u51e6\u7406\u306e\u73fe\u5834\u3067\u306f\u3001\u30a2\u30f3\u30e2\u30cb\u30a2\u6fc3\u5ea6\u306e\u7ba1\u7406\u306f\u51e6\u7406\u30d7\u30ed\u30bb\u30b9\u3092\u6b63\u5e38\u306b\u4fdd\u3061\u3001\u6cd5\u898f\u5236\u306b\u9069\u5408\u3059\u308b\u305f\u3081\u306b\u6b20\u304b\u2026","rel":"","context":"\u5206\u6790\u30fb\u6e2c\u5b9a\u95a2\u9023","block_context":{"text":"\u5206\u6790\u30fb\u6e2c\u5b9a\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/analysis\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/01\/environmental-analysis-laboratory-lpd-26008_eyecatch_.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/01\/environmental-analysis-laboratory-lpd-26008_eyecatch_.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/01\/environmental-analysis-laboratory-lpd-26008_eyecatch_.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/01\/environmental-analysis-laboratory-lpd-26008_eyecatch_.jpg?resize=700%2C400&ssl=1 2x"},"classes":[]},{"id":24552,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/qubit-dna-bid-ts-mbr-26001\/","url_meta":{"origin":419,"position":1},"title":"Qubit Fluorometer\u306b\u3064\u3044\u3066 \uff5eQubit Assay Kit\u306e\u6e2c\u5b9a\u7bc4\u56f2\uff5e","author":"LatB Staff","date":"2026\u5e741\u67089\u65e5","format":false,"excerpt":"Invitrogen\u2122 Qubit\u2122 Fluorometer \u306f\u3001\u5c02\u7528\u306e\u8a66\u85ac\u30ad\u30c3\u30c8\u3092\u7528\u3044\u308b\u3053\u3068\u3067DN\u2026","rel":"","context":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","block_context":{"text":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/mol-bio\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/12\/qubit-dna-bid-ts-mbr-26001_eyecatch.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/12\/qubit-dna-bid-ts-mbr-26001_eyecatch.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/12\/qubit-dna-bid-ts-mbr-26001_eyecatch.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/12\/qubit-dna-bid-ts-mbr-26001_eyecatch.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/12\/qubit-dna-bid-ts-mbr-26001_eyecatch.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/12\/qubit-dna-bid-ts-mbr-26001_eyecatch.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":24968,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/cloning-protein-expression-bid-ts-mbr-26012_\/","url_meta":{"origin":419,"position":2},"title":"\u5927\u8178\u83cc\u306e\u98fc\u3044\u65b9\uff5e\u5b9f\u9a13\u306b\u5fc5\u8981\u306a\u8a2d\u5099\u3092\u305d\u308d\u3048\u3088\u3046","author":"LatB Staff","date":"2026\u5e743\u670816\u65e5","format":false,"excerpt":"\u5206\u5b50\u751f\u7269\u5b66\u306e\u9ece\u660e\u671f\u3092\u652f\u3048\u3066\u304d\u305f\u5927\u8178\u83cc\uff08Escherichia coli\uff09\u3067\u3059\u304c\u3001\u8fd1\u5e74\u3067\u306f\u5168\u304f\u6271\u308f\u306a\u3044\u2026","rel":"","context":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","block_context":{"text":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/mol-bio\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/03\/cloning-protein-expression-bid-ts-mbr-26012_eyecatch.png?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/03\/cloning-protein-expression-bid-ts-mbr-26012_eyecatch.png?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/03\/cloning-protein-expression-bid-ts-mbr-26012_eyecatch.png?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/03\/cloning-protein-expression-bid-ts-mbr-26012_eyecatch.png?resize=700%2C400&ssl=1 2x"},"classes":[]},{"id":24614,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/battery-manufacturing-elemental-analysis-csm-26005\/","url_meta":{"origin":419,"position":3},"title":"\u96fb\u6c60\u30ea\u30b5\u30a4\u30af\u30eb\u306b\u304a\u3051\u308b\u5143\u7d20\u5206\u6790","author":"LatB Staff","date":"2026\u5e741\u670827\u65e5","format":false,"excerpt":"\u81ea\u52d5\u8eca\u306e\u96fb\u52d5\u5316\u3068\u518d\u751f\u53ef\u80fd\u30a8\u30cd\u30eb\u30ae\u30fc\u306e\u8caf\u8535\u80fd\u529b\u306e\u5897\u52a0\u306f\u3001\u3068\u3082\u306b\u96fb\u6c60\u306b\u5bfe\u3059\u308b\u9700\u8981\u306e\u5927\u5e45\u306a\u52a0\u901f\u3092\u3082\u305f\u3089\u3057\u3066\u2026","rel":"","context":"\u5206\u6790\u30fb\u6e2c\u5b9a\u95a2\u9023","block_context":{"text":"\u5206\u6790\u30fb\u6e2c\u5b9a\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/analysis\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/01\/battery-manufacturing-elemental-analysis-csm-26005_eyecatch.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/01\/battery-manufacturing-elemental-analysis-csm-26005_eyecatch.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/01\/battery-manufacturing-elemental-analysis-csm-26005_eyecatch.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/01\/battery-manufacturing-elemental-analysis-csm-26005_eyecatch.jpg?resize=700%2C400&ssl=1 2x"},"classes":[]},{"id":25592,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/ion-chromatography-contaminant-analysis-cmd-26024\/","url_meta":{"origin":419,"position":4},"title":"\u5316\u7ca7\u54c1\u4e2d\u306ePFAS\u5206\u6790\u3068\u306f\uff1f\u7dcf\u6709\u6a5f\u30d5\u30c3\u7d20\uff08TOF\uff09\u6e2c\u5b9a\u306b\u3088\u308b\u30b9\u30af\u30ea\u30fc\u30cb\u30f3\u30b0\u3068\u898f\u5236\u5bfe\u5fdc","author":"LatB Staff","date":"2026\u5e749\u670810\u65e5","format":false,"excerpt":"PFAS\uff08\u6709\u6a5f\u30d5\u30c3\u7d20\u5316\u5408\u7269\uff09\u306f\u3001\u300c\u6c38\u9060\u306e\u5316\u5b66\u7269\u8cea\uff08Forever Chemicals\uff09\u300d\u3068\u3082\u547c\u3070\u308c\u3001\u2026","rel":"","context":"\u5206\u6790\u30fb\u6e2c\u5b9a\u95a2\u9023","block_context":{"text":"\u5206\u6790\u30fb\u6e2c\u5b9a\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/analysis\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/08\/ion-chromatography-contaminant-analysis-cmd-26024_eyecatch.png?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/08\/ion-chromatography-contaminant-analysis-cmd-26024_eyecatch.png?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/08\/ion-chromatography-contaminant-analysis-cmd-26024_eyecatch.png?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/08\/ion-chromatography-contaminant-analysis-cmd-26024_eyecatch.png?resize=700%2C400&ssl=1 2x"},"classes":[]},{"id":24502,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/qubit-dna-bid-ts-mbr-25081\/","url_meta":{"origin":419,"position":5},"title":"Qubit \u30b7\u30ea\u30fc\u30ba Fluorometer\u306b\u3064\u3044\u3066","author":"LatB Staff","date":"2025\u5e7412\u670822\u65e5","format":false,"excerpt":"Invitrogen\u2122 Qubit\u2122\u30b7\u30ea\u30fc\u30ba Fluorometer\u306f\u3001\u5c02\u7528\u306e\u8a66\u85ac\u30ad\u30c3\u30c8\u3092\u7528\u3044\u308b\u3053\u3068\u2026","rel":"","context":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","block_context":{"text":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/mol-bio\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/12\/qubit-dna-bid-ts-mbr-25076_eyecatch.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/12\/qubit-dna-bid-ts-mbr-25076_eyecatch.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/12\/qubit-dna-bid-ts-mbr-25076_eyecatch.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/12\/qubit-dna-bid-ts-mbr-25076_eyecatch.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/12\/qubit-dna-bid-ts-mbr-25076_eyecatch.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/12\/qubit-dna-bid-ts-mbr-25076_eyecatch.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]}],"jetpack_sharing_enabled":true,"amp_enabled":true,"jetpack_featured_media_url":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/viscoelasticity-basic-title-2.jpg","_links":{"self":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/posts\/419","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/users\/988"}],"replies":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/comments?post=419"}],"version-history":[{"count":0,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/posts\/419\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/media\/2686"}],"wp:attachment":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/media?parent=419"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/categories?post=419"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/tags?post=419"},{"taxonomy":"division","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/division?post=419"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}