{"id":457,"date":"2020-03-04T00:00:00","date_gmt":"2020-03-03T15:00:00","guid":{"rendered":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/protein-assay-compatibility\/"},"modified":"2025-02-28T11:34:09","modified_gmt":"2025-02-28T02:34:09","slug":"protein-assay-compatibility","status":"publish","type":"post","link":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/protein-assay-compatibility\/","title":{"rendered":"\u3042\u306a\u305f\u306e\u30b5\u30f3\u30d7\u30eb\u306f\u5927\u4e08\u592b\uff1f\u7dcf\u30bf\u30f3\u30d1\u30af\u8cea\u5b9a\u91cf\u306e\u9069\u5408\u6027\u5224\u5b9a\u65b9\u6cd5"},"content":{"rendered":"<h2>\u306f\u3058\u3081\u306b<\/h2>\n<p>\u5f0a\u793e\u3067\u306f\u3055\u307e\u3056\u307e\u306a\u7dcf\u30bf\u30f3\u30d1\u30af\u8cea\u5b9a\u91cf\u7528\u8a66\u85ac\u3092\u3054\u7528\u610f\u3057\u3066\u3044\u307e\u3059\u304c\u3001<strong>\u3069\u306e\u5b9a\u91cf\u6cd5\u306b\u304a\u3044\u3066\u3082\u826f\u304f\u304a\u554f\u3044\u5408\u308f\u305b\u3044\u305f\u3060\u304f\u306e\u304c\u3001\u300c\u81ea\u5206\u306e\u30b5\u30f3\u30d7\u30eb\u306f\u6e2c\u5b9a\u3067\u304d\u308b\u304b\uff1f\u300d\u3068\u3044\u3046\u3054\u8cea\u554f\u3067\u3059<\/strong>\u3002\u4eca\u56de\u306f<strong>\u5404\u5b9a\u91cf\u6cd5\u306b\u304a\u3051\u308b\u5171\u5b58\u8a31\u5bb9\u6210\u5206\u306e\u60c5\u5831\u3084\u8907\u6570\u306e\u6210\u5206\u304c\u5171\u5b58\u3057\u3066\u3044\u308b\u5834\u5408\u306e\u9069\u5408\u6027\u5224\u5b9a\u65b9\u6cd5<\/strong>\u306b\u3064\u3044\u3066\u3054\u7d39\u4ecb\u3057\u307e\u3059\u3002<\/p>\n<p>\u5206\u5149\u5149\u5ea6\u8a08\u3092\u7528\u3044\u305f\u7dcf\u30bf\u30f3\u30d1\u30af\u8cea\u5b9a\u91cf\u306b\u306f\u3001\u3055\u307e\u3056\u307e\u306a\u6e2c\u5b9a\u65b9\u6cd5\u304c\u3042\u308a\u307e\u3059\u3002\u6e2c\u5b9a\u30b5\u30f3\u30d7\u30eb\u306b\u9069\u3057\u305f\u6e2c\u5b9a\u6cd5\u3092\u9078\u629e\u3059\u308b\u306b\u306f\u3001\u5404\u5b9a\u91cf\u6cd5\u306e\u7279\u5fb4\u3092\u77e5\u3063\u3066\u304a\u304f\u5fc5\u8981\u304c\u3042\u308a\u307e\u3059\u3002\u5f0a\u793e\u306e\u7dcf\u30bf\u30f3\u30d1\u30af\u8cea\u5b9a\u91cf\u8a66\u85ac\u306b\u95a2\u3059\u308b\u3001\u7279\u5fb4\u3084\u9078\u629e\u65b9\u6cd5\u306b\u3064\u3044\u3066\u306f\u3001\u4ee5\u524d\u306e\u8a18\u4e8b\u3092\u3054\u53c2\u7167\u304f\u3060\u3055\u3044\u3002<\/p>\n<p><a href=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/protein-basic3\/?CID=Social_LAB\" target=\"_blank\" rel=\"noopener\">\u201c\u7dcf\u201d\u30bf\u30f3\u30d1\u30af\u8cea\u5b9a\u91cf\u6cd5\u306e\u7a2e\u985e\u3092\u307e\u3068\u3081\u3066\u307f\u305f\uff5c\u77e5\u3063\u3066\u304a\u304d\u305f\u3044\uff01\u30bf\u30f3\u30d1\u30af\u8cea\u5b9f\u9a13\u3042\u308c\u3053\u308c \u7b2c3\u56de \u00bb<\/a><br \/>\n<a href=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/protein-basic4\/?CID=Social_LAB\" target=\"_blank\" rel=\"noopener\">BCA\u6cd5\u3001Bradford\u6cd5\u3001Lowry\u6cd5\u306a\u3069\u3001\u201c\u7dcf\u201d\u30bf\u30f3\u30d1\u30af\u8cea\u5b9a\u91cf\u6cd5\u306e\u539f\u7406\u307e\u3068\u3081\uff5c\u77e5\u3063\u3066\u304a\u304d\u305f\u3044\uff01\u30bf\u30f3\u30d1\u30af\u8cea\u5b9f\u9a13\u3042\u308c\u3053\u308c \u7b2c4\u56de \u00bb<\/a><\/p>\n<h2>\u5171\u5b58\u8a31\u5bb9\u6210\u5206\u3068\u6fc3\u5ea6<\/h2>\n<p>\u5f0a\u793e\u3067\u306f\u3001<strong>\u751f\u5316\u5b66\u5b9f\u9a13\u3067\u4e00\u822c\u7684\u306b\u4f7f\u7528\u3055\u308c\u308b\u6210\u5206\u3084\u30d0\u30c3\u30d5\u30a1\u30fc\u985e\u306e\u9069\u5408\u6fc3\u5ea6\u306b\u3064\u3044\u3066\u3001\u5f0a\u793e\u306e\u7dcf\u30bf\u30f3\u30d1\u30af\u8cea\u5b9a\u91cf\u8a66\u85ac\u6bce\u306b\u307e\u3068\u3081\u305f\u8868\u3092\u516c\u958b\u3057\u3066\u3044\u307e\u3059<\/strong>\u3002\u4e0b\u8a18\u306e\u753b\u50cf\u3092\u30af\u30ea\u30c3\u30af\u3057\u3066\u8a73\u7d30\u3092\u3054\u78ba\u8a8d\u304f\u3060\u3055\u3044\uff082\u30da\u30fc\u30b8\u76ee\u4ee5\u964d\u306b\u8868\u304c\u3042\u308a\u307e\u3059\uff09\u3002<\/p>\n<div id=\"attachment_1312\" style=\"width: 510px\" class=\"wp-caption aligncenter\"><a href=\"https:\/\/tools.thermofisher.com\/content\/sfs\/brochures\/TR0068-Protein-assay-compatibility.pdf?CID=Social_LAB\" rel=\"attachment wp-att-1312\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-1312\" class=\"wp-image-1312 size-full\" src=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/protein-assay-compatibility-fig1.jpg\" alt=\"protein-assay-compatibility-fig1\" width=\"500\" height=\"241\" \/><\/a><p id=\"caption-attachment-1312\" class=\"wp-caption-text\"><a href=\"https:\/\/tools.thermofisher.com\/content\/sfs\/brochures\/TR0068-Protein-assay-compatibility.pdf?CID=bid_pca_sbu_r04_jp_cp0000_pjt0000_bid00000_0so_blg_op_awa_oc_s00_pa35_Social_LAB\" target=\"_blank\" rel=\"noopener noreferrer\">Protein assay compatibility table<\/a> (\u30af\u30ea\u30c3\u30af\u3059\u308b\u3068PDF\u30d5\u30a1\u30a4\u30eb\u304c\u958b\u304d\u307e\u3059)<\/p><\/div>\n<p>\u8868\u4e2d\u306e\u5de6\u7aef\u306e\u5217\u306b\u306f\u5404\u6210\u5206\u540d\u3092\u3001\u53f3\u5074\u306e\u5217\u306b\u306f\u5404\u30bf\u30f3\u30d1\u30af\u8cea\u5b9a\u91cf\u6cd5\u306b\u304a\u3051\u308b\u5171\u5b58\u8a31\u5bb9\u6fc3\u5ea6\u3092\u8a18\u8f09\u3057\u3066\u3044\u307e\u3059\u3002\u4f8b\u3048\u3070\u30012-Mercaptoethanol\u306f\u3001660 nm\uff08<a href=\"https:\/\/www.thermofisher.com\/order\/catalog\/product\/22660?CID=bid_pca_sbu_r04_jp_cp0000_pjt0000_bid00000_0so_blg_op_awa_oc_s00_pa35_Social_LAB\" target=\"_blank\" rel=\"noopener noreferrer\">Pierce 660 nm Protein Assay<\/a>\uff09\u306e\u5834\u5408\u30011M\u307e\u3067\u5171\u5b58\u3057\u3066\u3082\u6e2c\u5b9a\u306f\u963b\u5bb3\u3055\u308c\u307e\u305b\u3093\u304c\u3001BCA\uff08<a href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/life-science\/protein-biology\/protein-assays-analysis\/protein-assays\/bca-protein-assays.html?CID=bid_pca_sbu_r04_jp_cp0000_pjt0000_bid00000_0so_blg_op_awa_oc_s00_pa35_Social_LAB\" target=\"_blank\" rel=\"noopener noreferrer\">BCA Protein Assay<\/a>\uff09\u306e\u5834\u5408\u30010.01%\u3088\u308a\u9ad8\u3044\u6fc3\u5ea6\u3067\u5171\u5b58\u3059\u308b\u3068\u6e2c\u5b9a\u304c\u963b\u5bb3\u3055\u308c\u307e\u3059\u3002\u307e\u305f\u30012\u30da\u30fc\u30b8\u76ee\u4e00\u756a\u4e0b\u306b\u8a18\u8f09\u306e<a href=\"https:\/\/www.thermofisher.com\/order\/catalog\/product\/78503?CID=bid_pca_sbu_r04_jp_cp0000_pjt0000_bid00000_0so_blg_op_awa_oc_s00_pa35_Social_LAB\" target=\"_blank\" rel=\"noopener noreferrer\">M-PER\u2122 Mammalian Protein Extraction Reagent<\/a>\uff08\u54fa\u4e73\u985e\u57f9\u990a\u7d30\u80de\u304b\u3089\u306e\u30bf\u30f3\u30d1\u30af\u8cea\u62bd\u51fa\u8a66\u85ac\uff09\u306f\u3001660 nm Protein Assay\u306e\u5834\u5408\u30012\u500d\u5e0c\u91c8\u3059\u308c\u3070\u6e2c\u5b9a\u306f\u963b\u5bb3\u3055\u308c\u305a\u3001BCA Protein Assay\u306e\u5834\u5408\u3001\u5e0c\u91c8\u4e0d\u8981\u3067\u76f4\u63a5\u6e2c\u5b9a\u304c\u53ef\u80fd\u3067\u3059\u3002<\/p>\n<p>\u306a\u304a\u3001\u8868\u4e2d\u306e\u6fc3\u5ea6\u306f\u3001\u5404\u30bf\u30f3\u30d1\u30af\u8cea\u5b9a\u91cf\u6cd5\u306b\u304a\u3051\u308btest tube\u6cd5\u3092\u7528\u3044\u3066\u5f0a\u793e\u3067\u30c6\u30b9\u30c8\u3057\u305f\u6700\u5927\u306e\u5171\u5b58\u8a31\u5bb9\u6fc3\u5ea6\u3067\u3059\u304c\u3001\u3042\u304f\u307e\u3067\u5de6\u7aef\u306e\u5404\u6210\u5206\u304c\u5358\u72ec\u3067\u5b58\u5728\u3059\u308b\u5834\u5408\u306e\u8a31\u5bb9\u6fc3\u5ea6\u3067\u3059\u3002\u5225\u306e\u6210\u5206\u304c\u6df7\u5408\u3055\u308c\u308b\u3068\u3001\u8a31\u5bb9\u6fc3\u5ea6\u304c\u8868\u4e2d\u306e\u5024\u3088\u308a\u3082\u4e0b\u304c\u308b\u3053\u3068\u304c\u3042\u308a\u307e\u3059\u306e\u3067\u3054\u6ce8\u610f\u304f\u3060\u3055\u3044\u3002<\/p>\n<h2>\u8907\u6570\u306e\u6210\u5206\u304c\u5171\u5b58\u3057\u3066\u3044\u3066\u9069\u5408\u6027\u304c\u4e0d\u660e\u306a\u5834\u5408<\/h2>\n<p>\u30bf\u30f3\u30d1\u30af\u8cea\u6eb6\u6db2\u4e2d\u306b\u8907\u6570\u306e\u6210\u5206\u304c\u5171\u5b58\u3057\u3066\u3044\u308b\u5834\u5408\u3001\u5171\u5b58\u8a31\u5bb9\u6fc3\u5ea6\u306e\u4e00\u89a7\u8868\u304b\u3089\u3067\u306f\u9069\u5408\u6027\u3092\u4e88\u60f3\u3059\u308b\u3053\u3068\u304c\u56f0\u96e3\u3067\u3059\u3002\u3053\u306e\u3088\u3046\u306a\u5834\u5408\u306b\u306f\u3001<strong>\u30b5\u30f3\u30d7\u30eb\u6e2c\u5b9a\u524d\u306b\u3001\u691c\u91cf\u7dda\u3092\u4f5c\u6210\u3057\u3066\u9069\u5408\u6027\u3092\u78ba\u8a8d<\/strong>\u3057\u307e\u3059\u3002\u5177\u4f53\u7684\u306b\u306f\u6b21\u306e\u624b\u9806\u3067\u78ba\u8a8d\u3057\u307e\u3059\u3002<\/p>\n<ol>\n<li>\u6c34\u307e\u305f\u306fPBS\u306a\u3069\u6e2c\u5b9a\u3092\u963b\u5bb3\u3057\u306a\u3044\u30d0\u30c3\u30d5\u30a1\u30fc\u3067\u30b9\u30bf\u30f3\u30c0\u30fc\u30c9\uff08BSA\u306a\u3069\uff09\u3092\u5e0c\u91c8\u3057\u3066\u691c\u91cf\u7dda\u3092\u4f5c\u6210<\/li>\n<li>\u30b5\u30f3\u30d7\u30eb\u3068\u540c\u3058\u7d44\u6210\u3067\u30bf\u30f3\u30d1\u30af\u8cea\u3092\u542b\u307e\u306a\u3044\u6eb6\u6db2\uff08\u30bf\u30f3\u30d1\u30af\u8cea\u304c\u6eb6\u3051\u3066\u3044\u308b\u6eb6\u5a92\uff09\u3092\u6e96\u5099<\/li>\n<li>1\u306e\u6eb6\u6db2\u3067\u691c\u91cf\u7dda\u3092\u4f5c\u6210<\/li>\n<li>1\u30683\u3067\u4f5c\u6210\u3057\u305f\u691c\u91cf\u7dda\u3092\u6bd4\u8f03<\/li>\n<\/ol>\n<p>\u691c\u91cf\u7dda\u6bd4\u8f03\u3092\u884c\u3063\u305f\u3068\u304d\u3001\u6fc3\u5ea6\u306e\u8aa4\u5dee\u304c10%\u4ee5\u5185\u3067\u3042\u308c\u30702\u306e\u6eb6\u6db2\u304c\u9069\u5408\u3059\u308b\u3068\u5224\u65ad\u3057\u307e\u3059\u3002\u8aa4\u5dee\u304c10%\u3092\u8d85\u3048\u308b\u5834\u5408\u306f\u30012\u306e\u6eb6\u6db2\u3092\u4f55\u500d\u304b\u306b\u5e0c\u91c8\u3057\u3001\u5e0c\u91c8\u6eb6\u5a92\u30673\u30684\u3092\u884c\u3044\u307e\u3059\u3002<\/p>\n<div id=\"attachment_1314\" style=\"width: 510px\" class=\"wp-caption aligncenter\"><a href=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/protein-assay-compatibility-fig2.jpg\" rel=\"attachment wp-att-1314\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-1314\" class=\"size-full wp-image-1314\" src=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/protein-assay-compatibility-fig2.jpg\" alt=\"protein-assay-compatibility-fig2\" width=\"500\" height=\"232\" \/><\/a><p id=\"caption-attachment-1314\" class=\"wp-caption-text\">\u56f3 \u691c\u91cf\u7dda\u306e\u6bd4\u8f03<\/p><\/div>\n<p>\u4f8b\u3048\u3070\u3001PBS\u3067\u4f5c\u6210\u3057\u305f\u691c\u91cf\u7dda\uff08\u56f3\u4e2d\u306e\u9752\u8272\u5b9f\u7dda\uff09\u3067\u306f\u5438\u5149\u5ea6\u304c1.4\u306e\u3068\u304d1,000 \u00b5g\/mL\u3067\u3059\u304c\u3001\u30bf\u30f3\u30d1\u30af\u8cea\u304c\u6eb6\u3051\u3066\u3044\u308b\u6eb6\u5a92\u3067\u4f5c\u6210\u3057\u305f\u691c\u91cf\u7dda\uff08\u56f3\u4e2d\u306e\u7dd1\u8272\u70b9\u7dda\uff09\u3092\u898b\u308b\u3068\u30011,460 \u00b5g\/mL\u3068\u5927\u304d\u304f\u305a\u308c\u3066\u304a\u308a\u3001\u6e2c\u5b9a\u304c\u963b\u5bb3\u3055\u308c\u3066\u3044\u308b\u3053\u3068\u304c\u5206\u304b\u308a\u307e\u3059\u3002\u305d\u3053\u3067\u3001\u30bf\u30f3\u30d1\u30af\u8cea\u304c\u6eb6\u3051\u3066\u3044\u308b\u6eb6\u5a92\u3092\u6c34\u306710\u500d\u5e0c\u91c8\u3057\u3001\u305d\u306e\u6eb6\u6db2\u3067\u4f5c\u6210\u3057\u305f\u691c\u91cf\u7dda\uff08\u56f3\u4e2d\u306e\u6a59\u8272\u70b9\u7dda\uff09\u3092\u898b\u308b\u30681,020 \u00b5g\/mL\u3068\u306a\u308a\u3001PBS\u3067\u4f5c\u6210\u3057\u305f\u691c\u91cf\u7dda\u3068\u6bd4\u3079\u306610%\u4ee5\u5185\u306e\u8aa4\u5dee\u7bc4\u56f2\u306b\u3042\u308a\u307e\u3059\u3002\u3053\u306e\u4f8b\u3067\u306f\u3001\u5438\u5149\u5ea6\u304c2\u306e\u4ed8\u8fd1\u3067\u6bd4\u8f03\u3057\u3066\u3082\u3001\u30bf\u30f3\u30d1\u30af\u8cea\u304c\u6eb6\u3051\u3066\u3044\u308b\u6eb6\u5a92\u309210\u500d\u5e0c\u91c8\u3059\u308c\u3070\u6fc3\u5ea6\u306e\u8aa4\u5dee\u304c10%\u4ee5\u5185\u306b\u3042\u308b\u3053\u3068\u304c\u5206\u304b\u308a\u307e\u3059\u3002\u3057\u305f\u304c\u3063\u3066\u3001\u3053\u306e\u4f8b\u3067\u306f\u3001\u30b5\u30f3\u30d7\u30eb\u309210\u500d\u5e0c\u91c8\u3057\u3066\u304b\u3089\u6e2c\u5b9a\u3057\u3001\u691c\u91cf\u7dda\u304b\u3089\u5f97\u3089\u308c\u305f\u6fc3\u5ea6\u309210\u500d\u3057\u305f\u5024\u304c\u30b5\u30f3\u30d7\u30eb\u306e\u7dcf\u30bf\u30f3\u30d1\u30af\u8cea\u6fc3\u5ea6\u3067\u3059\u3002\u306a\u304a\u3001<strong>\u5e0c\u91c8\u3057\u3066\u3082\u6fc3\u5ea6\u306e\u8aa4\u5dee\u304c\u5927\u304d\u3044\u5834\u5408\u306b\u306f\u3001\u6e2c\u5b9a\u3092\u963b\u5bb3\u3059\u308b\u6210\u5206\u3092\u9664\u53bb\u3059\u308b\u5fc5\u8981\u304c\u3042\u308a\u307e\u3059<\/strong>\u3002\u963b\u5bb3\u6210\u5206\u306e\u9664\u53bb\u306b\u306f\u8131\u5869\u3001\u900f\u6790\u3001\u30bf\u30f3\u30d1\u30af\u8cea\u6c88\u6bbf\u6cd5\u304c\u5229\u7528\u3067\u304d\u307e\u3059\u3002<\/p>\n<h2>\u3010\u7121\u6599\u30c0\u30a6\u30f3\u30ed\u30fc\u30c9\u3011\u30bf\u30f3\u30d1\u30af\u8cea\u89e3\u6790\u30ef\u30fc\u30af\u30d5\u30ed\u30fc\u30cf\u30f3\u30c9\u30d6\u30c3\u30af<\/h2>\n<p>\u52b9\u7387\u7684\u306a\u30bf\u30f3\u30d1\u30af\u8cea\u62bd\u51fa\u304b\u3089\u30a6\u30a7\u30b9\u30bf\u30f3\u30d6\u30ed\u30c3\u30c6\u30a3\u30f3\u30b0\u306e\u89e3\u6790\u30c4\u30fc\u30eb\u307e\u3067\u3001\u5305\u62ec\u7684\u306b\u30bd\u30ea\u30e5\u30fc\u30b7\u30e7\u30f3\u3092\u7d39\u4ecb\u3057\u3066\u304a\u308a\u307e\u3059\u3002PDF\u30d5\u30a1\u30a4\u30eb\u306e\u30c0\u30a6\u30f3\u30ed\u30fc\u30c9\u3092\u3054\u5e0c\u671b\u306e\u65b9\u306f\u3001\u4e0b\u8a18\u30dc\u30bf\u30f3\u3088\u308a\u304a\u7533\u8fbc\u307f\u304f\u3060\u3055\u3044\u3002<\/p>\n<p><a class=\"btn btn-red\" href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/global\/forms\/catalogs-protein-form.html?CID=bid_pca_sbu_r04_jp_cp0000_pjt0000_bid00000_0so_blg_op_awa_oc_s00_pa35_Social_LAB\" target=\"_blank\" rel=\"noopener\">\u30c0\u30a6\u30f3\u30ed\u30fc\u30c9\u3059\u308b<\/a><\/p>\n<p>&nbsp;<\/p>\n<p>\u7814\u7a76\u7528\u306b\u306e\u307f\u4f7f\u7528\u3067\u304d\u307e\u3059\u3002\u8a3a\u65ad\u7528\u306b\u306f\u4f7f\u7528\u3044\u305f\u3060\u3051\u307e\u305b\u3093\u3002<\/p>\n","protected":false},"excerpt":{"rendered":"<p>\u5f0a\u793e\u3067\u306f\u3055\u307e\u3056\u307e\u306a\u7dcf\u30bf\u30f3\u30d1\u30af\u8cea\u5b9a\u91cf\u7528\u8a66\u85ac\u3092\u3054\u7528\u610f\u3057\u3066\u3044\u307e\u3059\u304c\u3001\u3069\u306e\u5b9a\u91cf\u6cd5\u306b\u304a\u3044\u3066\u3082\u826f\u304f\u304a\u554f\u3044\u5408\u308f\u305b\u3044\u305f\u3060\u304f\u306e\u304c\u3001\u300c\u81ea\u5206\u306e\u30b5\u30f3\u30d7\u30eb\u306f\u6e2c\u5b9a\u3067\u304d\u308b\u304b\uff1f\u300d\u3068\u3044\u3046\u3054\u8cea\u554f\u3067\u3059\u3002\u4eca\u56de\u306f\u5404\u5b9a\u91cf\u6cd5\u306b\u304a\u3051\u308b\u5171\u5b58\u8a31\u5bb9\u6210\u5206\u306e\u60c5\u5831\u3084\u8907\u6570\u306e\u6210\u5206\u304c\u5171\u5b58\u3057\u3066\u3044\u308b\u5834\u5408\u306e\u9069\u5408\u6027\u5224\u5b9a\u65b9\u6cd5\u306b\u3064\u3044\u3066\u3054\u7d39\u4ecb\u3057\u307e\u3059\u3002<\/p>\n","protected":false},"author":988,"featured_media":2740,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_monsterinsights_skip_tracking":false,"_genesis_hide_title":false,"_genesis_hide_breadcrumbs":false,"_genesis_hide_singular_image":false,"_genesis_hide_footer_widgets":false,"_genesis_custom_body_class":"","_genesis_custom_post_class":"","_genesis_layout":"","_jetpack_newsletter_access":"","_jetpack_dont_email_post_to_subs":false,"_jetpack_newsletter_tier_id":0,"_jetpack_memberships_contains_paywalled_content":false,"_jetpack_hide_featured_image":false,"_jetpack_featured_image_duplicate_dismissed":0,"_jetpack_feature_clip_id":0,"_jetpack_memberships_contains_paid_content":false,"footnotes":"","jetpack_post_was_ever_published":false},"categories":[156],"tags":[21],"division":[],"class_list":["post-457","post","type-post","status-publish","format-standard","has-post-thumbnail","category-mol-bio","tag-protein-analysis","entry"],"_selected_authors":"","_selected_reviewers":"","acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v28.9 (Yoast SEO v28.9) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>\u3042\u306a\u305f\u306e\u30b5\u30f3\u30d7\u30eb\u306f\u5927\u4e08\u592b\uff1f\u7dcf\u30bf\u30f3\u30d1\u30af\u8cea\u5b9a\u91cf\u306e\u9069\u5408\u6027\u5224\u5b9a\u65b9\u6cd5 - Learning at the Bench<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/protein-assay-compatibility\/\" \/>\n<meta property=\"og:locale\" content=\"ja_JP\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"\u3042\u306a\u305f\u306e\u30b5\u30f3\u30d7\u30eb\u306f\u5927\u4e08\u592b\uff1f\u7dcf\u30bf\u30f3\u30d1\u30af\u8cea\u5b9a\u91cf\u306e\u9069\u5408\u6027\u5224\u5b9a\u65b9\u6cd5\" \/>\n<meta property=\"og:description\" content=\"\u5f0a\u793e\u3067\u306f\u3055\u307e\u3056\u307e\u306a\u7dcf\u30bf\u30f3\u30d1\u30af\u8cea\u5b9a\u91cf\u7528\u8a66\u85ac\u3092\u3054\u7528\u610f\u3057\u3066\u3044\u307e\u3059\u304c\u3001\u3069\u306e\u5b9a\u91cf\u6cd5\u306b\u304a\u3044\u3066\u3082\u826f\u304f\u304a\u554f\u3044\u5408\u308f\u305b\u3044\u305f\u3060\u304f\u306e\u304c\u3001\u300c\u81ea\u5206\u306e\u30b5\u30f3\u30d7\u30eb\u306f\u6e2c\u5b9a\u3067\u304d\u308b\u304b\uff1f\u300d\u3068\u3044\u3046\u3054\u8cea\u554f\u3067\u3059\u3002\u4eca\u56de\u306f\u5404\u5b9a\u91cf\u6cd5\u306b\u304a\u3051\u308b\u5171\u5b58\u8a31\u5bb9\u6210\u5206\u306e\u60c5\u5831\u3084\u8907\u6570\u306e\u6210\u5206\u304c\u5171\u5b58\u3057\u3066\u3044\u308b\u5834\u5408\u306e\u9069\u5408\u6027\u5224\u5b9a\u65b9\u6cd5\u306b\u3064\u3044\u3066\u3054\u7d39\u4ecb\u3057\u307e\u3059\u3002\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/protein-assay-compatibility\/\" \/>\n<meta property=\"og:site_name\" content=\"Learning at the Bench\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/ThermoFisherJapan\" \/>\n<meta property=\"article:published_time\" content=\"2020-03-03T15:00:00+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2025-02-28T02:34:09+00:00\" \/>\n<meta property=\"og:image\" content=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/calculate-dye-protein-molar-ratios-title-1.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"1200\" \/>\n\t<meta property=\"og:image:height\" content=\"630\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"LATB Staff\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:creator\" content=\"@ThermoFisherJP\" \/>\n<meta name=\"twitter:site\" content=\"@ThermoFisherJP\" \/>\n<meta name=\"twitter:label1\" content=\"\u57f7\u7b46\u8005\" \/>\n\t<meta name=\"twitter:data1\" content=\"LATB Staff\" \/>\n\t<meta name=\"twitter:label2\" content=\"\u63a8\u5b9a\u8aad\u307f\u53d6\u308a\u6642\u9593\" \/>\n\t<meta name=\"twitter:data2\" content=\"6\u5206\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/protein-assay-compatibility\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/protein-assay-compatibility\\\/\"},\"author\":{\"name\":\"LATB Staff\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#\\\/schema\\\/person\\\/201e6a5abb838fa34e8ff0174b015d36\"},\"headline\":\"\u3042\u306a\u305f\u306e\u30b5\u30f3\u30d7\u30eb\u306f\u5927\u4e08\u592b\uff1f\u7dcf\u30bf\u30f3\u30d1\u30af\u8cea\u5b9a\u91cf\u306e\u9069\u5408\u6027\u5224\u5b9a\u65b9\u6cd5\",\"datePublished\":\"2020-03-03T15:00:00+00:00\",\"dateModified\":\"2025-02-28T02:34:09+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/protein-assay-compatibility\\\/\"},\"wordCount\":58,\"commentCount\":0,\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/protein-assay-compatibility\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2019\\\/07\\\/calculate-dye-protein-molar-ratios-title-1.jpg\",\"keywords\":[\"\u30bf\u30f3\u30d1\u30af\u8cea\u89e3\u6790\"],\"articleSection\":[\"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023\"],\"inLanguage\":\"ja\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/protein-assay-compatibility\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/protein-assay-compatibility\\\/\",\"url\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/protein-assay-compatibility\\\/\",\"name\":\"\u3042\u306a\u305f\u306e\u30b5\u30f3\u30d7\u30eb\u306f\u5927\u4e08\u592b\uff1f\u7dcf\u30bf\u30f3\u30d1\u30af\u8cea\u5b9a\u91cf\u306e\u9069\u5408\u6027\u5224\u5b9a\u65b9\u6cd5 - Learning at the Bench\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/protein-assay-compatibility\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/protein-assay-compatibility\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2019\\\/07\\\/calculate-dye-protein-molar-ratios-title-1.jpg\",\"datePublished\":\"2020-03-03T15:00:00+00:00\",\"dateModified\":\"2025-02-28T02:34:09+00:00\",\"author\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#\\\/schema\\\/person\\\/201e6a5abb838fa34e8ff0174b015d36\"},\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/protein-assay-compatibility\\\/#breadcrumb\"},\"inLanguage\":\"ja\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/protein-assay-compatibility\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"ja\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/protein-assay-compatibility\\\/#primaryimage\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2019\\\/07\\\/calculate-dye-protein-molar-ratios-title-1.jpg\",\"contentUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2019\\\/07\\\/calculate-dye-protein-molar-ratios-title-1.jpg\",\"width\":1200,\"height\":630,\"caption\":\"calculate-dye-protein-molar-ratios-title\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/protein-assay-compatibility\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"\u3042\u306a\u305f\u306e\u30b5\u30f3\u30d7\u30eb\u306f\u5927\u4e08\u592b\uff1f\u7dcf\u30bf\u30f3\u30d1\u30af\u8cea\u5b9a\u91cf\u306e\u9069\u5408\u6027\u5224\u5b9a\u65b9\u6cd5\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#website\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/\",\"name\":\"Learning at the Bench\",\"description\":\"\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"ja\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#\\\/schema\\\/person\\\/201e6a5abb838fa34e8ff0174b015d36\",\"name\":\"LATB Staff\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"ja\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/8803277856c8b753feb4217dff0f9953327452df1a615c3c88b2f9864efb2ddd?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/8803277856c8b753feb4217dff0f9953327452df1a615c3c88b2f9864efb2ddd?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/8803277856c8b753feb4217dff0f9953327452df1a615c3c88b2f9864efb2ddd?s=96&d=mm&r=g\",\"caption\":\"LATB Staff\"},\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/author\\\/latbstaff\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"\u3042\u306a\u305f\u306e\u30b5\u30f3\u30d7\u30eb\u306f\u5927\u4e08\u592b\uff1f\u7dcf\u30bf\u30f3\u30d1\u30af\u8cea\u5b9a\u91cf\u306e\u9069\u5408\u6027\u5224\u5b9a\u65b9\u6cd5 - Learning at the Bench","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/protein-assay-compatibility\/","og_locale":"ja_JP","og_type":"article","og_title":"\u3042\u306a\u305f\u306e\u30b5\u30f3\u30d7\u30eb\u306f\u5927\u4e08\u592b\uff1f\u7dcf\u30bf\u30f3\u30d1\u30af\u8cea\u5b9a\u91cf\u306e\u9069\u5408\u6027\u5224\u5b9a\u65b9\u6cd5","og_description":"\u5f0a\u793e\u3067\u306f\u3055\u307e\u3056\u307e\u306a\u7dcf\u30bf\u30f3\u30d1\u30af\u8cea\u5b9a\u91cf\u7528\u8a66\u85ac\u3092\u3054\u7528\u610f\u3057\u3066\u3044\u307e\u3059\u304c\u3001\u3069\u306e\u5b9a\u91cf\u6cd5\u306b\u304a\u3044\u3066\u3082\u826f\u304f\u304a\u554f\u3044\u5408\u308f\u305b\u3044\u305f\u3060\u304f\u306e\u304c\u3001\u300c\u81ea\u5206\u306e\u30b5\u30f3\u30d7\u30eb\u306f\u6e2c\u5b9a\u3067\u304d\u308b\u304b\uff1f\u300d\u3068\u3044\u3046\u3054\u8cea\u554f\u3067\u3059\u3002\u4eca\u56de\u306f\u5404\u5b9a\u91cf\u6cd5\u306b\u304a\u3051\u308b\u5171\u5b58\u8a31\u5bb9\u6210\u5206\u306e\u60c5\u5831\u3084\u8907\u6570\u306e\u6210\u5206\u304c\u5171\u5b58\u3057\u3066\u3044\u308b\u5834\u5408\u306e\u9069\u5408\u6027\u5224\u5b9a\u65b9\u6cd5\u306b\u3064\u3044\u3066\u3054\u7d39\u4ecb\u3057\u307e\u3059\u3002","og_url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/protein-assay-compatibility\/","og_site_name":"Learning at the Bench","article_publisher":"https:\/\/www.facebook.com\/ThermoFisherJapan","article_published_time":"2020-03-03T15:00:00+00:00","article_modified_time":"2025-02-28T02:34:09+00:00","og_image":[{"width":1200,"height":630,"url":"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/calculate-dye-protein-molar-ratios-title-1.jpg","type":"image\/jpeg"}],"author":"LATB Staff","twitter_card":"summary_large_image","twitter_creator":"@ThermoFisherJP","twitter_site":"@ThermoFisherJP","twitter_misc":{"\u57f7\u7b46\u8005":"LATB Staff","\u63a8\u5b9a\u8aad\u307f\u53d6\u308a\u6642\u9593":"6\u5206"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/protein-assay-compatibility\/#article","isPartOf":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/protein-assay-compatibility\/"},"author":{"name":"LATB Staff","@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#\/schema\/person\/201e6a5abb838fa34e8ff0174b015d36"},"headline":"\u3042\u306a\u305f\u306e\u30b5\u30f3\u30d7\u30eb\u306f\u5927\u4e08\u592b\uff1f\u7dcf\u30bf\u30f3\u30d1\u30af\u8cea\u5b9a\u91cf\u306e\u9069\u5408\u6027\u5224\u5b9a\u65b9\u6cd5","datePublished":"2020-03-03T15:00:00+00:00","dateModified":"2025-02-28T02:34:09+00:00","mainEntityOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/protein-assay-compatibility\/"},"wordCount":58,"commentCount":0,"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/protein-assay-compatibility\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/calculate-dye-protein-molar-ratios-title-1.jpg","keywords":["\u30bf\u30f3\u30d1\u30af\u8cea\u89e3\u6790"],"articleSection":["\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023"],"inLanguage":"ja","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/protein-assay-compatibility\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/protein-assay-compatibility\/","url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/protein-assay-compatibility\/","name":"\u3042\u306a\u305f\u306e\u30b5\u30f3\u30d7\u30eb\u306f\u5927\u4e08\u592b\uff1f\u7dcf\u30bf\u30f3\u30d1\u30af\u8cea\u5b9a\u91cf\u306e\u9069\u5408\u6027\u5224\u5b9a\u65b9\u6cd5 - Learning at the Bench","isPartOf":{"@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/protein-assay-compatibility\/#primaryimage"},"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/protein-assay-compatibility\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/calculate-dye-protein-molar-ratios-title-1.jpg","datePublished":"2020-03-03T15:00:00+00:00","dateModified":"2025-02-28T02:34:09+00:00","author":{"@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#\/schema\/person\/201e6a5abb838fa34e8ff0174b015d36"},"breadcrumb":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/protein-assay-compatibility\/#breadcrumb"},"inLanguage":"ja","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/protein-assay-compatibility\/"]}]},{"@type":"ImageObject","inLanguage":"ja","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/protein-assay-compatibility\/#primaryimage","url":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/calculate-dye-protein-molar-ratios-title-1.jpg","contentUrl":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/calculate-dye-protein-molar-ratios-title-1.jpg","width":1200,"height":630,"caption":"calculate-dye-protein-molar-ratios-title"},{"@type":"BreadcrumbList","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/protein-assay-compatibility\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/"},{"@type":"ListItem","position":2,"name":"\u3042\u306a\u305f\u306e\u30b5\u30f3\u30d7\u30eb\u306f\u5927\u4e08\u592b\uff1f\u7dcf\u30bf\u30f3\u30d1\u30af\u8cea\u5b9a\u91cf\u306e\u9069\u5408\u6027\u5224\u5b9a\u65b9\u6cd5"}]},{"@type":"WebSite","@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#website","url":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/","name":"Learning at the Bench","description":"","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"ja"},{"@type":"Person","@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#\/schema\/person\/201e6a5abb838fa34e8ff0174b015d36","name":"LATB Staff","image":{"@type":"ImageObject","inLanguage":"ja","@id":"https:\/\/secure.gravatar.com\/avatar\/8803277856c8b753feb4217dff0f9953327452df1a615c3c88b2f9864efb2ddd?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/8803277856c8b753feb4217dff0f9953327452df1a615c3c88b2f9864efb2ddd?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/8803277856c8b753feb4217dff0f9953327452df1a615c3c88b2f9864efb2ddd?s=96&d=mm&r=g","caption":"LATB Staff"},"url":"https:\/\/admin.acceleratingscience.com\/author\/latbstaff\/"}]}},"taxonomy_info":{"category":[{"value":156,"label":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023"}],"post_tag":[{"value":21,"label":"\u30bf\u30f3\u30d1\u30af\u8cea\u89e3\u6790"}]},"featured_image_src_large":["https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/calculate-dye-protein-molar-ratios-title-1-1024x538.jpg",760,399,true],"author_info":{"display_name":"LATB Staff","author_link":"https:\/\/admin.acceleratingscience.com\/author\/latbstaff\/"},"comment_info":0,"category_info":[{"term_id":156,"name":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","slug":"mol-bio","term_group":0,"term_taxonomy_id":156,"taxonomy":"category","description":"","parent":0,"count":540,"filter":"raw","meta":[],"cat_ID":156,"category_count":540,"category_description":"","cat_name":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","category_nicename":"mol-bio","category_parent":0}],"tag_info":[{"term_id":21,"name":"\u30bf\u30f3\u30d1\u30af\u8cea\u89e3\u6790","slug":"protein-analysis","term_group":0,"term_taxonomy_id":21,"taxonomy":"post_tag","description":"","parent":0,"count":33,"filter":"raw","meta":[]}],"jetpack-related-posts":[{"id":24552,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/qubit-dna-bid-ts-mbr-26001\/","url_meta":{"origin":457,"position":0},"title":"Qubit Fluorometer\u306b\u3064\u3044\u3066 \uff5eQubit Assay Kit\u306e\u6e2c\u5b9a\u7bc4\u56f2\uff5e","author":"LatB Staff","date":"2026\u5e741\u67089\u65e5","format":false,"excerpt":"Invitrogen\u2122 Qubit\u2122 Fluorometer \u306f\u3001\u5c02\u7528\u306e\u8a66\u85ac\u30ad\u30c3\u30c8\u3092\u7528\u3044\u308b\u3053\u3068\u3067DN\u2026","rel":"","context":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","block_context":{"text":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/mol-bio\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/12\/qubit-dna-bid-ts-mbr-26001_eyecatch.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/12\/qubit-dna-bid-ts-mbr-26001_eyecatch.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/12\/qubit-dna-bid-ts-mbr-26001_eyecatch.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/12\/qubit-dna-bid-ts-mbr-26001_eyecatch.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/12\/qubit-dna-bid-ts-mbr-26001_eyecatch.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/12\/qubit-dna-bid-ts-mbr-26001_eyecatch.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":24502,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/qubit-dna-bid-ts-mbr-25081\/","url_meta":{"origin":457,"position":1},"title":"Qubit \u30b7\u30ea\u30fc\u30ba Fluorometer\u306b\u3064\u3044\u3066","author":"LatB Staff","date":"2025\u5e7412\u670822\u65e5","format":false,"excerpt":"Invitrogen\u2122 Qubit\u2122\u30b7\u30ea\u30fc\u30ba Fluorometer\u306f\u3001\u5c02\u7528\u306e\u8a66\u85ac\u30ad\u30c3\u30c8\u3092\u7528\u3044\u308b\u3053\u3068\u2026","rel":"","context":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","block_context":{"text":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/mol-bio\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/12\/qubit-dna-bid-ts-mbr-25076_eyecatch.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/12\/qubit-dna-bid-ts-mbr-25076_eyecatch.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/12\/qubit-dna-bid-ts-mbr-25076_eyecatch.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/12\/qubit-dna-bid-ts-mbr-25076_eyecatch.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/12\/qubit-dna-bid-ts-mbr-25076_eyecatch.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/12\/qubit-dna-bid-ts-mbr-25076_eyecatch.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":24108,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/cell-culture-cell-count-bid-ts-mbr-25065-2\/","url_meta":{"origin":457,"position":2},"title":"\u3010\u7b2c6\u56de\u3011 \u30a6\u30a7\u30b9\u30bf\u30f3\u30d6\u30ed\u30c3\u30c6\u30a3\u30f3\u30b0\u6cd5\u306b\u3088\u308b \u300e\u30a8\u30af\u30bd\u30bd\u30fc\u30e0\u4e2d\u306e\u30bf\u30f3\u30d1\u30af\u8cea\uff08Protein cargo\uff09\u300f\u306e\u89e3\u6790","author":"LatB Staff","date":"2026\u5e747\u670815\u65e5","format":false,"excerpt":"\u30a8\u30af\u30bd\u30bd\u30fc\u30e0\uff08\u30a8\u30ad\u30bd\u30bd\u30fc\u30e0\uff09\u306f\u3001\u7d30\u80de\u304b\u3089\u5206\u6ccc\u3055\u308c\u308b\u5c0f\u3055\u306a\u819c\u5c0f\u80de\u3067\u3001\u6838\u9178\uff08RNA\uff0fDNA\uff09\u3060\u3051\u3067\u306a\u304f\u3001\u2026","rel":"","context":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","block_context":{"text":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/mol-bio\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/11\/cell-culture-cell-count-bid-ts-mbr-25065_eyecatch.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/11\/cell-culture-cell-count-bid-ts-mbr-25065_eyecatch.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/11\/cell-culture-cell-count-bid-ts-mbr-25065_eyecatch.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/11\/cell-culture-cell-count-bid-ts-mbr-25065_eyecatch.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/11\/cell-culture-cell-count-bid-ts-mbr-25065_eyecatch.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/11\/cell-culture-cell-count-bid-ts-mbr-25065_eyecatch.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":25247,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/exosome-gene-expression-ts-r-25018\/","url_meta":{"origin":457,"position":3},"title":"\u3010\u7b2c4\u56de\u3011&#8221;RNA cargo&#8221;\u306e\u7cbe\u88fd\u3068\u5b9a\u91cf\u89e3\u6790\uff5emiRNA\u306e\u5b9a\u91cf\u89e3\u6790\uff5e","author":"LatB Staff","date":"2026\u5e745\u670829\u65e5","format":false,"excerpt":"\u524d\u56de\uff08\u3010\u7b2c3\u56de\u3011\u201cRNA cargo\u201d\u306e\u7cbe\u88fd\u3068\u5b9a\u91cf\u89e3\u6790\uff09\u3067\u306f\u3001\u30a8\u30af\u30bd\u30bd\u30fc\u30e0 \uff08\u30a8\u30ad\u30bd\u30bd\u30fc\u30e0\uff09 \u304b\u3089\u306e\u2026","rel":"","context":"\u5206\u6790\u30fb\u6e2c\u5b9a\u95a2\u9023","block_context":{"text":"\u5206\u6790\u30fb\u6e2c\u5b9a\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/analysis\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25018_eyecatch-1.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25018_eyecatch-1.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25018_eyecatch-1.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25018_eyecatch-1.jpg?resize=700%2C400&ssl=1 2x"},"classes":[]},{"id":25325,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/exosome-gene-expression-ts-r-25019\/","url_meta":{"origin":457,"position":4},"title":"\u3010\u7b2c5\u56de\u3011 &#8220;RNA cargo&#8221;\u306e\u7cbe\u88fd\u3068\u5b9a\u91cf\u89e3\u6790\u300d\uff5emRNA\u306e\u5b9a\u91cf\u89e3\u6790\uff5e","author":"LatB Staff","date":"2026\u5e746\u670811\u65e5","format":false,"excerpt":"\u4eca\u56de\u306f\u3001\u30a8\u30af\u30bd\u30bd\u30fc\u30e0\uff08\u30a8\u30ad\u30bd\u30bd\u30fc\u30e0\uff09\u4e2d\u306emRNA\u306e\u5b9a\u91cf\u89e3\u6790\u306b\u3064\u3044\u3066\u8aac\u660e\u3057\u307e\u3059\u3002\u7b2c3\u56de\u3067\u30a8\u30af\u30bd\u30bd\u30fc\u30e0\u304b\u2026","rel":"","context":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","block_context":{"text":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/mol-bio\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25018_eyecatch-1.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25018_eyecatch-1.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25018_eyecatch-1.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25018_eyecatch-1.jpg?resize=700%2C400&ssl=1 2x"},"classes":[]},{"id":25472,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/exosome-ts-r-25067\/","url_meta":{"origin":457,"position":5},"title":"\u3010\u7b2c7\u56de\u3011 \u30a8\u30af\u30bd\u30bd\u30fc\u30e0\u30b5\u30d6\u30bf\u30a4\u30d7\u306e\u5206\u753b\u306e\u6982\u8981","author":"LatB Staff","date":"2026\u5e748\u670813\u65e5","format":false,"excerpt":"\u7d30\u80de\u304c\u5206\u6ccc\u3059\u308b\u7d30\u80de\u5916\u5c0f\u80de\u306e\u4e2d\u3067\u3082\u3001\u30a8\u30af\u30bd\u30bd\u30fc\u30e0\u306f\u305d\u306e\u60c5\u5831\u4f1d\u9054\u6a5f\u80fd\u3084\u75be\u60a3\u3068\u306e\u95a2\u9023\u6027\u304b\u3089\u6ce8\u76ee\u3092\u96c6\u3081\u3066\u3044\u307e\u2026","rel":"","context":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","block_context":{"text":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/mol-bio\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25019_eyecatch.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25019_eyecatch.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25019_eyecatch.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25019_eyecatch.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25019_eyecatch.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25019_eyecatch.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]}],"jetpack_sharing_enabled":true,"amp_enabled":true,"jetpack_featured_media_url":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/calculate-dye-protein-molar-ratios-title-1.jpg","_links":{"self":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/posts\/457","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/users\/988"}],"replies":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/comments?post=457"}],"version-history":[{"count":0,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/posts\/457\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/media\/2740"}],"wp:attachment":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/media?parent=457"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/categories?post=457"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/tags?post=457"},{"taxonomy":"division","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/division?post=457"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}