{"id":463,"date":"2020-03-04T00:00:00","date_gmt":"2020-03-03T15:00:00","guid":{"rendered":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/remove-detergent-from-protein-samples\/"},"modified":"2025-01-21T16:16:57","modified_gmt":"2025-01-21T07:16:57","slug":"remove-detergent-from-protein-samples","status":"publish","type":"post","link":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/remove-detergent-from-protein-samples\/","title":{"rendered":"\u30bf\u30f3\u30d1\u30af\u8cea\u30b5\u30f3\u30d7\u30eb\u304b\u3089\u9ad8\u6fc3\u5ea6\u306e\u754c\u9762\u6d3b\u6027\u5264\u3092\u52b9\u7387\u3088\u304f\u8fc5\u901f\u306b\u9664\u53bb\u3059\u308b\u65b9\u6cd5"},"content":{"rendered":"<p>\u7d30\u80de\u3084\u7d44\u7e54\u304b\u3089\u30bf\u30f3\u30d1\u30af\u8cea\u30b5\u30f3\u30d7\u30eb\u3092\u8abf\u88fd\u3059\u308b\u3068\u304d\u3001<strong>\u758e\u6c34\u6027\u30bf\u30f3\u30d1\u30af\u8cea\u3092\u53ef\u6eb6\u5316\u3059\u308b\u76ee\u7684\u3067\u754c\u9762\u6d3b\u6027\u5264\u304c\u7528\u3044\u3089\u308c\u307e\u3059\u304c\u3001\u7d9a\u3044\u3066\u884c\u308f\u308c\u308b\u4e0b\u6d41\u306e\u5b9f\u9a13\u306b\u3088\u3063\u3066\u306f\u754c\u9762\u6d3b\u6027\u5264\u304c\u963b\u5bb3\u56e0\u5b50\u3068\u306a\u308b\u305f\u3081\u3001\u30b5\u30f3\u30d7\u30eb\u304b\u3089\u9664\u53bb\u3057\u306a\u3051\u308c\u3070\u306a\u3089\u306a\u3044\u5834\u5408\u304c\u3042\u308a\u307e\u3059<\/strong>\u3002\u4f8b\u3048\u3070\u3001\u754c\u9762\u6d3b\u6027\u5264\u304c\u30bf\u30f3\u30d1\u30af\u8cea\u306e\u6d3b\u6027\u3092\u963b\u5bb3\u3057\u3066\u3057\u307e\u3046\u5834\u5408\u3001\u30bf\u30f3\u30d1\u30af\u8cea\u5b9a\u91cf\u3084\u96fb\u6c17\u6cf3\u52d5\u306b\u9069\u5408\u3057\u306a\u3044\u5834\u5408\u306a\u3069\u3067\u3059\u3002\u754c\u9762\u6d3b\u6027\u5264\u3092\u9664\u304f\u65b9\u6cd5\u3068\u3057\u3066\u306f\u3001\u900f\u6790\u3084\u9650\u5916\u308d\u904e\u306b\u3088\u308a\u4f4e\u5206\u5b50\u3092\u9664\u53bb\u3059\u308b\u65b9\u6cd5\u3001\u3042\u308b\u3044\u306f\u30bf\u30f3\u30d1\u30af\u8cea\u3092\u6c88\u6bbf\u3055\u305b\u3001\u518d\u6eb6\u89e3\u3059\u308b\u65b9\u6cd5\u304c\u3042\u3052\u3089\u308c\u307e\u3059\u3002<\/p>\n<p>\u754c\u9762\u6d3b\u6027\u5264\u306f\u3001\u81e8\u754c\u30df\u30bb\u30eb\u6fc3\u5ea6\uff08Critical Micelle Concentration: CMC\uff09\u3092\u8d85\u3048\u308b\u3068\u30df\u30bb\u30eb\u3092\u5f62\u6210\u3059\u308b\u6027\u8cea\u3092\u3082\u3061\u3001\u30bf\u30f3\u30d1\u30af\u8cea\u306e\u53ef\u6eb6\u5316\u3067\u306fCMC\u4ee5\u4e0a\u306e\u6fc3\u5ea6\u3067\u4f7f\u7528\u3057\u307e\u3059\u3002\u900f\u6790\u3084\u9650\u5916\u308d\u904e\u306f\u3001CMC\u304c\u9ad8\u3044\u754c\u9762\u6d3b\u6027\u5264\u3084\u30df\u30bb\u30eb\u4f1a\u5408\u6570\u304c\u5c0f\u3055\u3044\u754c\u9762\u6d3b\u6027\u5264\u306e\u9664\u53bb\u306b\u306f\u6709\u7528\u3067\u3059\u304c\u3001CMC\u304c\u4f4e\u3044\u5834\u5408\u3084\u30df\u30bb\u30eb\u4f1a\u5408\u6570\u304c\u5927\u304d\u3044\u5834\u5408\u3001<strong>\u307b\u3068\u3093\u3069\u306e\u754c\u9762\u6d3b\u6027\u5264\u304c\u900f\u6790\u819c\u306e\u30dd\u30a2\u30b5\u30a4\u30ba\u3088\u308a\u3082\u5927\u304d\u3044\u30df\u30bb\u30eb\u72b6\u614b\u3067\u5b58\u5728\u3057\u3066\u304a\u308a\u3001\u52b9\u7387\u3088\u304f\u9664\u53bb\u3059\u308b\u3053\u3068\u306f\u56f0\u96e3<\/strong>\u3067\u3059\u3002\u307e\u305f<strong>\u30bf\u30f3\u30d1\u30af\u8cea\u6c88\u6bbf\u6cd5\u3082\u3001\u30bf\u30f3\u30d1\u30af\u8cea\u304c\u5909\u6027\u3059\u308b\u3001\u3042\u308b\u3044\u306f\u30bf\u30f3\u30d1\u30af\u8cea\u306e\u518d\u6eb6\u89e3\u304c\u3067\u304d\u306a\u304f\u306a\u308b\u53ef\u80fd\u6027\u304c\u3042\u308a\u307e\u3059<\/strong>\u3002<\/p>\n<p><a href=\"https:\/\/www.thermofisher.com\/order\/catalog\/product\/87777?CID=bid_pca_sbu_r04_jp_cp0000_pjt0000_bid00000_0so_blg_op_awa_oc_s00_pa38_Social_LAB\" target=\"_blank\" rel=\"noopener noreferrer\">Pierce\u2122 Detergent Removal Spin Columns<\/a>\u306f\u3001\u30bf\u30f3\u30d1\u30af\u8cea\u6eb6\u6db2\u3084\u30da\u30d7\u30c1\u30c9\u6eb6\u6db2\u304b\u3089SDS, CHAPS, Triton X-100, NP-40\u306a\u3069\u306e\u754c\u9762\u6d3b\u6027\u5264\uff081-5%\uff09\u3092<strong>95%\u4ee5\u4e0a\u306e\u52b9\u7387\u3067\u3001\u8fc5\u901f\u306b\u9664\u53bb\u3059\u308b\u305f\u3081\u306e\u30b9\u30d4\u30f3\u30ab\u30e9\u30e0<\/strong>\u3067\u3059\u3002\u30b9\u30d4\u30f3\u30ab\u30e9\u30e0\u306b\u5145\u586b\u6e08\u307f\u306e\u30ec\u30b8\u30f3\u306f\u3001\u30bf\u30f3\u30d1\u30af\u8cea\u62bd\u51fa\u3084\u30b5\u30f3\u30d7\u30eb\u8abf\u88fd\u3067\u4f7f\u7528\u3055\u308c\u308b\u4e00\u822c\u7684\u306a\u754c\u9762\u6d3b\u6027\u5264\u3068\u30a2\u30d5\u30a3\u30cb\u30c6\u30a3\u30fc\u7d50\u5408\u3057\u307e\u3059\u3002\u64cd\u4f5c\u306f\u30ec\u30b8\u30f3\u306e\u5e73\u8861\u5316\u3001\u30b5\u30f3\u30d7\u30eb\u306e\u6dfb\u52a0\u30fb\u30a4\u30f3\u30ad\u30e5\u30d9\u30fc\u30b7\u30e7\u30f3\u30fb\u56de\u53ce\u3068\u7c21\u4fbf\u3067\u300110\u5206\u4ee5\u5185\u306b\u754c\u9762\u6d3b\u6027\u5264\u306e\u9664\u53bb\u304c\u5b8c\u4e86\u3057\u307e\u3059\u3002\u900f\u6790\u3084\u9650\u5916\u308d\u904e\u306b\u304a\u3044\u3066\u61f8\u5ff5\u3055\u308c\u308b\u3001<strong>\u30bf\u30f3\u30d1\u30af\u8cea\u3084\u30da\u30d7\u30c1\u30c9\u306e\u975e\u7279\u7570\u7684\u5438\u7740\u306b\u3088\u308b\u30ed\u30b9\u306f\u5c11\u91cf\u3067\u3059<\/strong>\uff08\u88681\u53c2\u7167\uff09\u3002\u307e\u305f\u3001\u4f4e\u6fc3\u5ea6\u306e\u30bf\u30f3\u30d1\u30af\u8cea\u6eb6\u6db2\u304b\u3089\u754c\u9762\u6d3b\u6027\u5264\u3092\u9664\u53bb\u3057\u305f\u3044\u5834\u5408\u306b\u306f\u3001<a href=\"https:\/\/www.thermofisher.com\/order\/catalog\/product\/88305?CID=bid_pca_sbu_r04_jp_cp0000_pjt0000_bid00000_0so_blg_op_awa_oc_s00_pa38_Social_LAB\" target=\"_blank\" rel=\"noopener noreferrer\">HiPPR\u2122 Detergent Removal Spin Column Kit<\/a>\u304c\u6709\u52b9\u3067\u3059\u3002<strong>1-100 \u03bcg\/mL\u306e\u4f4e\u6fc3\u5ea6\u30bf\u30f3\u30d1\u30af\u8cea\u6eb6\u6db2\u304b\u3089\u3001\u754c\u9762\u6d3b\u6027\u5264\uff080.5-1%\uff09\u309295%\u4ee5\u4e0a\u9664\u53bb\u3067\u304d\u307e\u3059<\/strong>\u3002<\/p>\n<p>\u4e0b\u8a18\u306e\u8868\u3067\u306f\u3001\u754c\u9762\u6d3b\u6027\u5264\u3092\u542b\u3080BSA\uff080.1 mL, 100 \u03bcg\uff09\u3092<a href=\"https:\/\/www.thermofisher.com\/order\/catalog\/product\/87777?CID=bid_pca_sbu_r04_jp_cp0000_pjt0000_bid00000_0so_blg_op_awa_oc_s00_pa38_Social_LAB\" target=\"_blank\" rel=\"noopener noreferrer\">Pierce\u2122 Detergent Removal Spin Columns<\/a>\u3067\u51e6\u7406\u3057\u3001\u754c\u9762\u6d3b\u6027\u5264\u306e\u9664\u53bb\u7387\u3068\u30bf\u30f3\u30d1\u30af\u8cea\u56de\u53ce\u7387\u3092\u6e2c\u5b9a\u3057\u307e\u3057\u305f\u3002BSA\u4ee5\u5916\u3067\u3082\u3001insulin\uff085.7 kDa\uff09\u3001\u03b1-lactalbumin\uff0814.2 kDa\uff09\u3001carbonic anhydrase\uff0829 kDa\uff09\u3067\u305d\u308c\u305e\u308c\u540c\u69d8\u306e\u7d50\u679c\u304c\u5f97\u3089\u308c\u3066\u3044\u307e\u3059\u3002<\/p>\n<table>\n<caption>\u8868 \u5404\u754c\u9762\u6d3b\u6027\u5264\u306e\u9664\u53bb\u7387\u3068\u30bf\u30f3\u30d1\u30af\u8cea\u56de\u53ce\u7387<\/caption>\n<tbody>\n<tr>\n<td>\u754c\u9762\u6d3b\u6027\u5264<\/td>\n<td>\u754c\u9762\u6d3b\u6027\u5264\u9664\u53bb\u7387 (%)<\/td>\n<td>BSA \u56de\u53ce\u7387 (%)<\/td>\n<\/tr>\n<tr>\n<td>SDS, 2.5%<\/td>\n<td>99<\/td>\n<td>95<\/td>\n<\/tr>\n<tr>\n<td>CHAPS, 3%<\/td>\n<td>99<\/td>\n<td>90<\/td>\n<\/tr>\n<tr>\n<td>Triton X-100, 2%<\/td>\n<td>99<\/td>\n<td>87<\/td>\n<\/tr>\n<tr>\n<td>NP-40, 1%<\/td>\n<td>95<\/td>\n<td>91<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><span style=\"font-size: 8pt\">\u203b\u305d\u306e\u4ed6\u306e\u754c\u9762\u6d3b\u6027\u5264\u306e\u9664\u53bb\u7387\u306b\u3064\u304d\u307e\u3057\u3066\u306f\u3001<a href=\"https:\/\/www.thermofisher.com\/order\/catalog\/product\/87777?CID=bid_pca_sbu_r04_jp_cp0000_pjt0000_bid00000_0so_blg_op_awa_oc_s00_pa38_Social_LAB\" target=\"_blank\" rel=\"noopener noreferrer\">Pierce\u2122 Detergent Removal Spin Columns<\/a>\u306e\u88fd\u54c1\u60c5\u5831\u30da\u30fc\u30b8\u3092\u3054\u53c2\u7167\u304f\u3060\u3055\u3044\u3002<\/span><\/p>\n<p>&nbsp;<\/p>\n<h2>\u3010\u7121\u6599\u30c0\u30a6\u30f3\u30ed\u30fc\u30c9\u3011\u30bf\u30f3\u30d1\u30af\u8cea\u89e3\u6790\u30ef\u30fc\u30af\u30d5\u30ed\u30fc\u30cf\u30f3\u30c9\u30d6\u30c3\u30af<\/h2>\n<p>\u52b9\u7387\u7684\u306a\u30bf\u30f3\u30d1\u30af\u8cea\u62bd\u51fa\u304b\u3089\u30a6\u30a7\u30b9\u30bf\u30f3\u30d6\u30ed\u30c3\u30c6\u30a3\u30f3\u30b0\u306e\u89e3\u6790\u30c4\u30fc\u30eb\u307e\u3067\u3001\u5305\u62ec\u7684\u306b\u30bd\u30ea\u30e5\u30fc\u30b7\u30e7\u30f3\u3092\u7d39\u4ecb\u3057\u3066\u304a\u308a\u307e\u3059\u3002PDF\u30d5\u30a1\u30a4\u30eb\u306e\u30c0\u30a6\u30f3\u30ed\u30fc\u30c9\u3092\u3054\u5e0c\u671b\u306e\u65b9\u306f\u3001\u4e0b\u8a18\u30dc\u30bf\u30f3\u3088\u308a\u304a\u7533\u8fbc\u307f\u304f\u3060\u3055\u3044\u3002<\/p>\n<p><a class=\"btn btn-red\" href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/global\/forms\/catalogs-protein-form.html?CID=bid_pca_sbu_r04_jp_cp0000_pjt0000_bid00000_0so_blg_op_awa_oc_s00_pa38_Social_LAB\" target=\"_blank\" rel=\"noopener\">\u30c0\u30a6\u30f3\u30ed\u30fc\u30c9\u3059\u308b<\/a><\/p>\n<p>&nbsp;<\/p>\n<p>\u7814\u7a76\u7528\u306b\u306e\u307f\u4f7f\u7528\u3067\u304d\u307e\u3059\u3002\u8a3a\u65ad\u76ee\u7684\u304a\u3088\u3073\u305d\u306e\u624b\u7d9a\u304d\u4e0a\u3067\u306e\u4f7f\u7528\u306f\u3067\u304d\u307e\u305b\u3093\u3002<\/p>\n","protected":false},"excerpt":{"rendered":"<p>\u7d30\u80de\u3084\u7d44\u7e54\u304b\u3089\u30bf\u30f3\u30d1\u30af\u8cea\u30b5\u30f3\u30d7\u30eb\u3092\u8abf\u88fd\u3059\u308b\u3068\u304d\u3001\u758e\u6c34\u6027\u30bf\u30f3\u30d1\u30af\u8cea\u3092\u53ef\u6eb6\u5316\u3059\u308b\u76ee\u7684\u3067\u754c\u9762\u6d3b\u6027\u5264\u304c\u7528\u3044\u3089\u308c\u307e\u3059\u304c\u3001\u7d9a\u3044\u3066\u884c\u308f\u308c\u308b\u4e0b\u6d41\u306e\u5b9f\u9a13\u306b\u3088\u3063\u3066\u306f\u754c\u9762\u6d3b\u6027\u5264\u304c\u963b\u5bb3\u56e0\u5b50\u3068\u306a\u308b\u305f\u3081\u3001\u30b5\u30f3\u30d7\u30eb\u304b\u3089\u9664\u53bb\u3057\u306a\u3051\u308c\u3070\u306a\u3089\u306a\u3044\u5834\u5408\u304c\u3042\u308a\u307e\u3059\u3002\u4eca\u56de\u306f\u3001\u30bf\u30f3\u30d1\u30af\u8cea\u30b5\u30f3\u30d7\u30eb\u304b\u3089\u754c\u9762\u6d3b\u6027\u5264\u3092\u52b9\u7387\u3088\u304f\u8fc5\u901f\u306b\u9664\u53bb\u3059\u308b\u88fd\u54c1\u3092\u3054\u7d39\u4ecb\u3057\u307e\u3059\u3002<\/p>\n","protected":false},"author":988,"featured_media":2747,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_monsterinsights_skip_tracking":false,"_genesis_hide_title":false,"_genesis_hide_breadcrumbs":false,"_genesis_hide_singular_image":false,"_genesis_hide_footer_widgets":false,"_genesis_custom_body_class":"","_genesis_custom_post_class":"","_genesis_layout":"","_jetpack_newsletter_access":"","_jetpack_dont_email_post_to_subs":false,"_jetpack_newsletter_tier_id":0,"_jetpack_memberships_contains_paywalled_content":false,"_jetpack_feature_clip_id":0,"_jetpack_memberships_contains_paid_content":false,"footnotes":"","jetpack_post_was_ever_published":false},"categories":[156],"tags":[61,21],"division":[],"class_list":{"0":"post-463","1":"post","2":"type-post","3":"status-publish","4":"format-standard","5":"has-post-thumbnail","7":"category-mol-bio","8":"tag-protein-purification","9":"tag-protein-analysis","10":"entry"},"_selected_authors":"","_selected_reviewers":"","acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v27.8 (Yoast SEO v27.8) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>\u30bf\u30f3\u30d1\u30af\u8cea\u30b5\u30f3\u30d7\u30eb\u304b\u3089\u9ad8\u6fc3\u5ea6\u306e\u754c\u9762\u6d3b\u6027\u5264\u3092\u52b9\u7387\u3088\u304f\u8fc5\u901f\u306b\u9664\u53bb\u3059\u308b\u65b9\u6cd5 - Learning at the Bench<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/remove-detergent-from-protein-samples\/\" \/>\n<meta property=\"og:locale\" content=\"ja_JP\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"\u30bf\u30f3\u30d1\u30af\u8cea\u30b5\u30f3\u30d7\u30eb\u304b\u3089\u9ad8\u6fc3\u5ea6\u306e\u754c\u9762\u6d3b\u6027\u5264\u3092\u52b9\u7387\u3088\u304f\u8fc5\u901f\u306b\u9664\u53bb\u3059\u308b\u65b9\u6cd5\" \/>\n<meta property=\"og:description\" content=\"\u7d30\u80de\u3084\u7d44\u7e54\u304b\u3089\u30bf\u30f3\u30d1\u30af\u8cea\u30b5\u30f3\u30d7\u30eb\u3092\u8abf\u88fd\u3059\u308b\u3068\u304d\u3001\u758e\u6c34\u6027\u30bf\u30f3\u30d1\u30af\u8cea\u3092\u53ef\u6eb6\u5316\u3059\u308b\u76ee\u7684\u3067\u754c\u9762\u6d3b\u6027\u5264\u304c\u7528\u3044\u3089\u308c\u307e\u3059\u304c\u3001\u7d9a\u3044\u3066\u884c\u308f\u308c\u308b\u4e0b\u6d41\u306e\u5b9f\u9a13\u306b\u3088\u3063\u3066\u306f\u754c\u9762\u6d3b\u6027\u5264\u304c\u963b\u5bb3\u56e0\u5b50\u3068\u306a\u308b\u305f\u3081\u3001\u30b5\u30f3\u30d7\u30eb\u304b\u3089\u9664\u53bb\u3057\u306a\u3051\u308c\u3070\u306a\u3089\u306a\u3044\u5834\u5408\u304c\u3042\u308a\u307e\u3059\u3002\u4eca\u56de\u306f\u3001\u30bf\u30f3\u30d1\u30af\u8cea\u30b5\u30f3\u30d7\u30eb\u304b\u3089\u754c\u9762\u6d3b\u6027\u5264\u3092\u52b9\u7387\u3088\u304f\u8fc5\u901f\u306b\u9664\u53bb\u3059\u308b\u88fd\u54c1\u3092\u3054\u7d39\u4ecb\u3057\u307e\u3059\u3002\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/remove-detergent-from-protein-samples\/\" \/>\n<meta property=\"og:site_name\" content=\"Learning at the Bench\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/ThermoFisherJapan\" \/>\n<meta property=\"article:published_time\" content=\"2020-03-03T15:00:00+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2025-01-21T07:16:57+00:00\" \/>\n<meta property=\"og:image\" content=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/remove-detergent-from-protein-samples-title.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"1200\" \/>\n\t<meta property=\"og:image:height\" content=\"630\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"LATB Staff\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:creator\" content=\"@ThermoFisherJP\" \/>\n<meta name=\"twitter:site\" content=\"@ThermoFisherJP\" \/>\n<meta name=\"twitter:label1\" content=\"\u57f7\u7b46\u8005\" \/>\n\t<meta name=\"twitter:data1\" content=\"LATB Staff\" \/>\n\t<meta name=\"twitter:label2\" content=\"\u63a8\u5b9a\u8aad\u307f\u53d6\u308a\u6642\u9593\" \/>\n\t<meta name=\"twitter:data2\" content=\"4\u5206\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/remove-detergent-from-protein-samples\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/remove-detergent-from-protein-samples\\\/\"},\"author\":{\"name\":\"LATB Staff\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#\\\/schema\\\/person\\\/00a095a01d54afcdf9457465feb04f7d\"},\"headline\":\"\u30bf\u30f3\u30d1\u30af\u8cea\u30b5\u30f3\u30d7\u30eb\u304b\u3089\u9ad8\u6fc3\u5ea6\u306e\u754c\u9762\u6d3b\u6027\u5264\u3092\u52b9\u7387\u3088\u304f\u8fc5\u901f\u306b\u9664\u53bb\u3059\u308b\u65b9\u6cd5\",\"datePublished\":\"2020-03-03T15:00:00+00:00\",\"dateModified\":\"2025-01-21T07:16:57+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/remove-detergent-from-protein-samples\\\/\"},\"wordCount\":58,\"commentCount\":0,\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/remove-detergent-from-protein-samples\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2019\\\/07\\\/remove-detergent-from-protein-samples-title.jpg\",\"keywords\":[\"\u30bf\u30f3\u30d1\u30af\u8cea\u7cbe\u88fd\",\"\u30bf\u30f3\u30d1\u30af\u8cea\u89e3\u6790\"],\"articleSection\":[\"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023\"],\"inLanguage\":\"ja\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/remove-detergent-from-protein-samples\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/remove-detergent-from-protein-samples\\\/\",\"url\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/remove-detergent-from-protein-samples\\\/\",\"name\":\"\u30bf\u30f3\u30d1\u30af\u8cea\u30b5\u30f3\u30d7\u30eb\u304b\u3089\u9ad8\u6fc3\u5ea6\u306e\u754c\u9762\u6d3b\u6027\u5264\u3092\u52b9\u7387\u3088\u304f\u8fc5\u901f\u306b\u9664\u53bb\u3059\u308b\u65b9\u6cd5 - Learning at the Bench\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/remove-detergent-from-protein-samples\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/remove-detergent-from-protein-samples\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2019\\\/07\\\/remove-detergent-from-protein-samples-title.jpg\",\"datePublished\":\"2020-03-03T15:00:00+00:00\",\"dateModified\":\"2025-01-21T07:16:57+00:00\",\"author\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#\\\/schema\\\/person\\\/00a095a01d54afcdf9457465feb04f7d\"},\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/remove-detergent-from-protein-samples\\\/#breadcrumb\"},\"inLanguage\":\"ja\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/remove-detergent-from-protein-samples\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"ja\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/remove-detergent-from-protein-samples\\\/#primaryimage\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2019\\\/07\\\/remove-detergent-from-protein-samples-title.jpg\",\"contentUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2019\\\/07\\\/remove-detergent-from-protein-samples-title.jpg\",\"width\":1200,\"height\":630,\"caption\":\"remove-detergent-from-protein-samples-title\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/remove-detergent-from-protein-samples\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"\u30bf\u30f3\u30d1\u30af\u8cea\u30b5\u30f3\u30d7\u30eb\u304b\u3089\u9ad8\u6fc3\u5ea6\u306e\u754c\u9762\u6d3b\u6027\u5264\u3092\u52b9\u7387\u3088\u304f\u8fc5\u901f\u306b\u9664\u53bb\u3059\u308b\u65b9\u6cd5\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#website\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/\",\"name\":\"Learning at the Bench\",\"description\":\"\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"ja\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#\\\/schema\\\/person\\\/00a095a01d54afcdf9457465feb04f7d\",\"name\":\"LATB Staff\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"ja\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/8803277856c8b753feb4217dff0f9953327452df1a615c3c88b2f9864efb2ddd?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/8803277856c8b753feb4217dff0f9953327452df1a615c3c88b2f9864efb2ddd?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/8803277856c8b753feb4217dff0f9953327452df1a615c3c88b2f9864efb2ddd?s=96&d=mm&r=g\",\"caption\":\"LATB Staff\"},\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/author\\\/latbstaff\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"\u30bf\u30f3\u30d1\u30af\u8cea\u30b5\u30f3\u30d7\u30eb\u304b\u3089\u9ad8\u6fc3\u5ea6\u306e\u754c\u9762\u6d3b\u6027\u5264\u3092\u52b9\u7387\u3088\u304f\u8fc5\u901f\u306b\u9664\u53bb\u3059\u308b\u65b9\u6cd5 - Learning at the Bench","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/remove-detergent-from-protein-samples\/","og_locale":"ja_JP","og_type":"article","og_title":"\u30bf\u30f3\u30d1\u30af\u8cea\u30b5\u30f3\u30d7\u30eb\u304b\u3089\u9ad8\u6fc3\u5ea6\u306e\u754c\u9762\u6d3b\u6027\u5264\u3092\u52b9\u7387\u3088\u304f\u8fc5\u901f\u306b\u9664\u53bb\u3059\u308b\u65b9\u6cd5","og_description":"\u7d30\u80de\u3084\u7d44\u7e54\u304b\u3089\u30bf\u30f3\u30d1\u30af\u8cea\u30b5\u30f3\u30d7\u30eb\u3092\u8abf\u88fd\u3059\u308b\u3068\u304d\u3001\u758e\u6c34\u6027\u30bf\u30f3\u30d1\u30af\u8cea\u3092\u53ef\u6eb6\u5316\u3059\u308b\u76ee\u7684\u3067\u754c\u9762\u6d3b\u6027\u5264\u304c\u7528\u3044\u3089\u308c\u307e\u3059\u304c\u3001\u7d9a\u3044\u3066\u884c\u308f\u308c\u308b\u4e0b\u6d41\u306e\u5b9f\u9a13\u306b\u3088\u3063\u3066\u306f\u754c\u9762\u6d3b\u6027\u5264\u304c\u963b\u5bb3\u56e0\u5b50\u3068\u306a\u308b\u305f\u3081\u3001\u30b5\u30f3\u30d7\u30eb\u304b\u3089\u9664\u53bb\u3057\u306a\u3051\u308c\u3070\u306a\u3089\u306a\u3044\u5834\u5408\u304c\u3042\u308a\u307e\u3059\u3002\u4eca\u56de\u306f\u3001\u30bf\u30f3\u30d1\u30af\u8cea\u30b5\u30f3\u30d7\u30eb\u304b\u3089\u754c\u9762\u6d3b\u6027\u5264\u3092\u52b9\u7387\u3088\u304f\u8fc5\u901f\u306b\u9664\u53bb\u3059\u308b\u88fd\u54c1\u3092\u3054\u7d39\u4ecb\u3057\u307e\u3059\u3002","og_url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/remove-detergent-from-protein-samples\/","og_site_name":"Learning at the Bench","article_publisher":"https:\/\/www.facebook.com\/ThermoFisherJapan","article_published_time":"2020-03-03T15:00:00+00:00","article_modified_time":"2025-01-21T07:16:57+00:00","og_image":[{"width":1200,"height":630,"url":"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/remove-detergent-from-protein-samples-title.jpg","type":"image\/jpeg"}],"author":"LATB Staff","twitter_card":"summary_large_image","twitter_creator":"@ThermoFisherJP","twitter_site":"@ThermoFisherJP","twitter_misc":{"\u57f7\u7b46\u8005":"LATB Staff","\u63a8\u5b9a\u8aad\u307f\u53d6\u308a\u6642\u9593":"4\u5206"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/remove-detergent-from-protein-samples\/#article","isPartOf":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/remove-detergent-from-protein-samples\/"},"author":{"name":"LATB Staff","@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#\/schema\/person\/00a095a01d54afcdf9457465feb04f7d"},"headline":"\u30bf\u30f3\u30d1\u30af\u8cea\u30b5\u30f3\u30d7\u30eb\u304b\u3089\u9ad8\u6fc3\u5ea6\u306e\u754c\u9762\u6d3b\u6027\u5264\u3092\u52b9\u7387\u3088\u304f\u8fc5\u901f\u306b\u9664\u53bb\u3059\u308b\u65b9\u6cd5","datePublished":"2020-03-03T15:00:00+00:00","dateModified":"2025-01-21T07:16:57+00:00","mainEntityOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/remove-detergent-from-protein-samples\/"},"wordCount":58,"commentCount":0,"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/remove-detergent-from-protein-samples\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/remove-detergent-from-protein-samples-title.jpg","keywords":["\u30bf\u30f3\u30d1\u30af\u8cea\u7cbe\u88fd","\u30bf\u30f3\u30d1\u30af\u8cea\u89e3\u6790"],"articleSection":["\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023"],"inLanguage":"ja","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/remove-detergent-from-protein-samples\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/remove-detergent-from-protein-samples\/","url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/remove-detergent-from-protein-samples\/","name":"\u30bf\u30f3\u30d1\u30af\u8cea\u30b5\u30f3\u30d7\u30eb\u304b\u3089\u9ad8\u6fc3\u5ea6\u306e\u754c\u9762\u6d3b\u6027\u5264\u3092\u52b9\u7387\u3088\u304f\u8fc5\u901f\u306b\u9664\u53bb\u3059\u308b\u65b9\u6cd5 - Learning at the Bench","isPartOf":{"@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/remove-detergent-from-protein-samples\/#primaryimage"},"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/remove-detergent-from-protein-samples\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/remove-detergent-from-protein-samples-title.jpg","datePublished":"2020-03-03T15:00:00+00:00","dateModified":"2025-01-21T07:16:57+00:00","author":{"@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#\/schema\/person\/00a095a01d54afcdf9457465feb04f7d"},"breadcrumb":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/remove-detergent-from-protein-samples\/#breadcrumb"},"inLanguage":"ja","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/remove-detergent-from-protein-samples\/"]}]},{"@type":"ImageObject","inLanguage":"ja","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/remove-detergent-from-protein-samples\/#primaryimage","url":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/remove-detergent-from-protein-samples-title.jpg","contentUrl":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/remove-detergent-from-protein-samples-title.jpg","width":1200,"height":630,"caption":"remove-detergent-from-protein-samples-title"},{"@type":"BreadcrumbList","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/remove-detergent-from-protein-samples\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/"},{"@type":"ListItem","position":2,"name":"\u30bf\u30f3\u30d1\u30af\u8cea\u30b5\u30f3\u30d7\u30eb\u304b\u3089\u9ad8\u6fc3\u5ea6\u306e\u754c\u9762\u6d3b\u6027\u5264\u3092\u52b9\u7387\u3088\u304f\u8fc5\u901f\u306b\u9664\u53bb\u3059\u308b\u65b9\u6cd5"}]},{"@type":"WebSite","@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#website","url":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/","name":"Learning at the Bench","description":"","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"ja"},{"@type":"Person","@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#\/schema\/person\/00a095a01d54afcdf9457465feb04f7d","name":"LATB Staff","image":{"@type":"ImageObject","inLanguage":"ja","@id":"https:\/\/secure.gravatar.com\/avatar\/8803277856c8b753feb4217dff0f9953327452df1a615c3c88b2f9864efb2ddd?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/8803277856c8b753feb4217dff0f9953327452df1a615c3c88b2f9864efb2ddd?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/8803277856c8b753feb4217dff0f9953327452df1a615c3c88b2f9864efb2ddd?s=96&d=mm&r=g","caption":"LATB Staff"},"url":"https:\/\/admin.acceleratingscience.com\/author\/latbstaff\/"}]}},"taxonomy_info":{"category":[{"value":156,"label":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023"}],"post_tag":[{"value":61,"label":"\u30bf\u30f3\u30d1\u30af\u8cea\u7cbe\u88fd"},{"value":21,"label":"\u30bf\u30f3\u30d1\u30af\u8cea\u89e3\u6790"}]},"featured_image_src_large":["https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/remove-detergent-from-protein-samples-title-1024x538.jpg",760,399,true],"author_info":{"display_name":"LATB Staff","author_link":"https:\/\/admin.acceleratingscience.com\/author\/latbstaff\/"},"comment_info":0,"category_info":[{"term_id":156,"name":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","slug":"mol-bio","term_group":0,"term_taxonomy_id":156,"taxonomy":"category","description":"","parent":0,"count":538,"filter":"raw","meta":[],"cat_ID":156,"category_count":538,"category_description":"","cat_name":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","category_nicename":"mol-bio","category_parent":0}],"tag_info":[{"term_id":61,"name":"\u30bf\u30f3\u30d1\u30af\u8cea\u7cbe\u88fd","slug":"protein-purification","term_group":0,"term_taxonomy_id":61,"taxonomy":"post_tag","description":"","parent":0,"count":4,"filter":"raw","meta":[]},{"term_id":21,"name":"\u30bf\u30f3\u30d1\u30af\u8cea\u89e3\u6790","slug":"protein-analysis","term_group":0,"term_taxonomy_id":21,"taxonomy":"post_tag","description":"","parent":0,"count":33,"filter":"raw","meta":[]}],"jetpack-related-posts":[{"id":24606,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/transfection-antibody-bid-ts-mbr-26004\/","url_meta":{"origin":463,"position":0},"title":"\u7d30\u80de\u5185\u30bf\u30f3\u30d1\u30af\u8cea\u9664\u53bb\u30b7\u30b9\u30c6\u30e0\uff08Trim-Away\u6cd5\uff09\u306e\u7d39\u4ecb\uff5e\u30a8\u30ec\u30af\u30c8\u30ed\u30dd\u30ec\u30fc\u30b7\u30e7\u30f3\u6a5f\u5668\u3092\u4f7f\u7528\u3057\u3066\uff5e","author":"LatB Staff","date":"2026\u5e742\u67084\u65e5","format":false,"excerpt":"2018\u5e74\u306e\u6587\u732e(1)\u3067\u7d30\u80de\u5185\u306e\u5185\u5728\u6027\u30bf\u30f3\u30d1\u30af\u8cea\u3092\u76f4\u63a5\u5206\u89e3\u3059\u308b\u3001Trim-Away\u6cd5\u304c\u7d39\u4ecb\u3055\u308c\u307e\u3057\u305f\u2026","rel":"","context":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","block_context":{"text":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/mol-bio\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/01\/transfection-antibody-bid-ts-mbr-26004_eyecatch.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/01\/transfection-antibody-bid-ts-mbr-26004_eyecatch.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/01\/transfection-antibody-bid-ts-mbr-26004_eyecatch.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/01\/transfection-antibody-bid-ts-mbr-26004_eyecatch.jpg?resize=700%2C400&ssl=1 2x"},"classes":[]},{"id":24108,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/cell-culture-cell-count-bid-ts-mbr-25065-2\/","url_meta":{"origin":463,"position":1},"title":"\u3010\u7b2c6\u56de\u3011 \u30a6\u30a7\u30b9\u30bf\u30f3\u30d6\u30ed\u30c3\u30c6\u30a3\u30f3\u30b0\u6cd5\u306b\u3088\u308b \u300e\u30a8\u30af\u30bd\u30bd\u30fc\u30e0\u4e2d\u306e\u30bf\u30f3\u30d1\u30af\u8cea\uff08Protein cargo\uff09\u300f\u306e\u89e3\u6790","author":"LatB Staff","date":"2026\u5e747\u670815\u65e5","format":false,"excerpt":"\u30a8\u30af\u30bd\u30bd\u30fc\u30e0\uff08\u30a8\u30ad\u30bd\u30bd\u30fc\u30e0\uff09\u306f\u3001\u7d30\u80de\u304b\u3089\u5206\u6ccc\u3055\u308c\u308b\u5c0f\u3055\u306a\u819c\u5c0f\u80de\u3067\u3001\u6838\u9178\uff08RNA\uff0fDNA\uff09\u3060\u3051\u3067\u306a\u304f\u3001\u2026","rel":"","context":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","block_context":{"text":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/mol-bio\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/11\/cell-culture-cell-count-bid-ts-mbr-25065_eyecatch.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/11\/cell-culture-cell-count-bid-ts-mbr-25065_eyecatch.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/11\/cell-culture-cell-count-bid-ts-mbr-25065_eyecatch.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/11\/cell-culture-cell-count-bid-ts-mbr-25065_eyecatch.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/11\/cell-culture-cell-count-bid-ts-mbr-25065_eyecatch.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/11\/cell-culture-cell-count-bid-ts-mbr-25065_eyecatch.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":25540,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/cloning-cell-separation-bid-ts-mbr-26023\/","url_meta":{"origin":463,"position":2},"title":"\u5927\u8178\u83cc\u306e\u98fc\u3044\u65b92\uff5e\u5b9f\u969b\u306b\u57f9\u990a\u3057\u3066\u307f\u3088\u3046","author":"LatB Staff","date":"2026\u5e748\u670826\u65e5","format":false,"excerpt":"\u30d6\u30ed\u30b0\u300c\u5927\u8178\u83cc\u306e\u98fc\u3044\u65b9\uff5e\u5b9f\u9a13\u306b\u5fc5\u8981\u306a\u8a2d\u5099\u3092\u305d\u308d\u3048\u3088\u3046\u300d\u3067\u306f\u3001\u30af\u30ed\u30fc\u30cb\u30f3\u30b0\u3084\u7d44\u307f\u63db\u3048\u30bf\u30f3\u30d1\u30af\u8cea\u767a\u73fe\u306e\u7528\u2026","rel":"","context":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","block_context":{"text":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/mol-bio\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/08\/cloning-cell-separation-bid-ts-mbr-26023_eyecatch.png?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/08\/cloning-cell-separation-bid-ts-mbr-26023_eyecatch.png?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/08\/cloning-cell-separation-bid-ts-mbr-26023_eyecatch.png?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/08\/cloning-cell-separation-bid-ts-mbr-26023_eyecatch.png?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/08\/cloning-cell-separation-bid-ts-mbr-26023_eyecatch.png?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/08\/cloning-cell-separation-bid-ts-mbr-26023_eyecatch.png?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":25565,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/exosome-antibody-ts-r-25068\/","url_meta":{"origin":463,"position":3},"title":"\u3010\u7b2c8\u56de\u3011\u30a8\u30af\u30bd\u30bd\u30fc\u30e0\u30b5\u30d6\u30bf\u30a4\u30d7\u306e\u5206\u753b\u6cd5 \uff1a \u30a6\u30a7\u30b9\u30bf\u30f3\u30d6\u30ed\u30c3\u30c8\uff0fqRT-PCR\uff0f\u30b7\u30fc\u30b1\u30f3\u30b9\u89e3\u6790\u306b\u9069\u3057\u305f\u5206\u753b\u65b9\u6cd5","author":"LatB Staff","date":"2026\u5e749\u670829\u65e5","format":false,"excerpt":"\u672c\u7a3f\u3067\u306f\u3001\u30a8\u30af\u30bd\u30bd\u30fc\u30e0\u819c\u4e0a\u306e\u7279\u5b9a\u306e\u30bf\u30f3\u30d1\u30af\u8cea\u3092\u6a19\u7684\u3068\u3057\u305f\u514d\u75ab\u5438\u7740\u6cd5\u306b\u57fa\u3065\u304f\u5206\u753b\u624b\u6cd5\u3092\u7d39\u4ecb\u3057\u307e\u3059\u3002\u30a8\u30af\u2026","rel":"","context":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","block_context":{"text":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/mol-bio\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25019_eyecatch.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25019_eyecatch.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25019_eyecatch.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25019_eyecatch.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25019_eyecatch.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25019_eyecatch.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":25472,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/exosome-ts-r-25067\/","url_meta":{"origin":463,"position":4},"title":"\u3010\u7b2c7\u56de\u3011 \u30a8\u30af\u30bd\u30bd\u30fc\u30e0\u30b5\u30d6\u30bf\u30a4\u30d7\u306e\u5206\u753b\u306e\u6982\u8981","author":"LatB Staff","date":"2026\u5e748\u670813\u65e5","format":false,"excerpt":"\u7d30\u80de\u304c\u5206\u6ccc\u3059\u308b\u7d30\u80de\u5916\u5c0f\u80de\u306e\u4e2d\u3067\u3082\u3001\u30a8\u30af\u30bd\u30bd\u30fc\u30e0\u306f\u305d\u306e\u60c5\u5831\u4f1d\u9054\u6a5f\u80fd\u3084\u75be\u60a3\u3068\u306e\u95a2\u9023\u6027\u304b\u3089\u6ce8\u76ee\u3092\u96c6\u3081\u3066\u3044\u307e\u2026","rel":"","context":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","block_context":{"text":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/mol-bio\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25019_eyecatch.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25019_eyecatch.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25019_eyecatch.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25019_eyecatch.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25019_eyecatch.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25019_eyecatch.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":25000,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/nalgene-safety-control-lpd-26013\/","url_meta":{"origin":463,"position":5},"title":"\u30e9\u30dc\u30dc\u30c8\u30eb\u306e\u8010\u85ac\u54c1\u6027\u3068\u6c17\u5bc6\u6027\u3068\u306f\uff1f\uff5e \u610f\u5916\u3068\u77e5\u3089\u306a\u3044\u57fa\u672c\u306e\u8a71\uff5e","author":"LatB Staff","date":"2026\u5e743\u670826\u65e5","format":false,"excerpt":"\u30dc\u30c8\u30eb\u9078\u3073\u3001\u306a\u3093\u3068\u306a\u304f\u3067\u5927\u4e08\u592b\uff1f \u30d7\u30e9\u30b9\u30c1\u30c3\u30af\u88fd\u30dc\u30c8\u30eb\u306f\u3001\u30dc\u30c8\u30eb\u306e\u6a39\u8102\u3068\u5185\u5bb9\u7269\u306e\u76f8\u6027\u304c\u9069\u5207\u3067\u306a\u3044\u5834\u5408\u2026","rel":"","context":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","block_context":{"text":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/mol-bio\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/03\/nalgene-safety-control-lpd-26013_eyecatch.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/03\/nalgene-safety-control-lpd-26013_eyecatch.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/03\/nalgene-safety-control-lpd-26013_eyecatch.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/03\/nalgene-safety-control-lpd-26013_eyecatch.jpg?resize=700%2C400&ssl=1 2x"},"classes":[]}],"jetpack_sharing_enabled":true,"amp_enabled":true,"jetpack_featured_media_url":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/remove-detergent-from-protein-samples-title.jpg","_links":{"self":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/posts\/463","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/users\/988"}],"replies":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/comments?post=463"}],"version-history":[{"count":0,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/posts\/463\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/media\/2747"}],"wp:attachment":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/media?parent=463"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/categories?post=463"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/tags?post=463"},{"taxonomy":"division","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/division?post=463"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}