{"id":487,"date":"2016-09-27T00:00:00","date_gmt":"2016-09-27T00:00:00","guid":{"rendered":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/optimizing-western-blot-transfer\/"},"modified":"2025-01-22T14:51:20","modified_gmt":"2025-01-22T05:51:20","slug":"optimizing-western-blot-transfer","status":"publish","type":"post","link":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/optimizing-western-blot-transfer\/","title":{"rendered":"\u30a6\u30a7\u30b9\u30bf\u30f3\u30d6\u30ed\u30c3\u30c6\u30a3\u30f3\u30b0\u306b\u304a\u3051\u308b\u8ee2\u5199\u52b9\u7387\u306e\u6700\u9069\u5316"},"content":{"rendered":"<h2>\u306f\u3058\u3081\u306b<\/h2>\n<p>SDS\u30b1\u3099\u30eb\u304b\u3089\u306e\u30bf\u30f3\u30cf\u309a\u30af\u8cea\u306e\u96fb\u6c17\u30d5\u3099\u30ed\u30c3\u30c6\u30a3\u30f3\u30af\u3099\u3092\u6700\u9069\u5316\u3059\u308b\u305f\u3081\u306b\u306f\u6570\u591a\u304f\u306e\u30cf\u309a\u30e9\u30e1\u30fc\u30bf\u3092\u8003\u616e\u3059\u308b\u5fc5\u8981\u304b\u3099\u3042\u308a\u307e\u3059\u3002\u76ee\u6a19\u306f\u30b1\u3099\u30eb\u304b\u3089\u3059\u3078\u3099\u3066\u306e\u30bf\u30f3\u30cf\u309a\u30af\u8cea\u3092\u8ee2\u5199\u3055\u305b\u3001\u8ee2\u5199\u819c\u306b\u5b9a\u91cf\u7684\u306b\u8ee2\u5199\u3055\u305b\u308b\u3053\u3068\u3066\u3099\u3059\u3002\u9ad8\u3044\u8ee2\u5199\u52b9\u7387\u3092\u5f97\u308b\u305f\u3081\u306b\u306f\u3001\u3068\u304f\u306b\u5927\u304d\u306a\u30bf\u30f3\u30cf\u309a\u30af\u8cea\u3068\u5c0f\u3055\u306a\u30bf\u30f3\u30cf\u309a\u30af\u8cea\u306e\u8ee2\u5199\u3092\u6700\u9069\u5316\u3059\u308b\u5fc5\u8981\u304b\u3099\u3042\u308a\u307e\u3059\u3002<\/p>\n<p>\u8ee2\u5199\u5f8c\u3001\u30b1\u3099\u30eb\u306b\u306f\u30bf\u30f3\u30cf\u309a\u30af\u8cea\u306f\u6b8b\u5b58\u3057\u3066\u3044\u306a\u3044\u306f\u3059\u3099\u3066\u3099\u3059\u3002\u3053\u308c\u306f<strong>\u8ee2\u5199\u5f8c\u306b\u30b1\u3099\u30eb\u3092\u67d3\u8272\u3059\u308b\u3053\u3068\u306b\u3088\u3063\u3066\u30e2\u30cb\u30bf\u30fc\u3059\u308b\u3053\u3068\u304b\u3099\u3066\u3099\u304d\u307e\u3059\u3002<\/strong>\u30b1\u3099\u30eb\u304b\u3089\u8ee2\u5199\u3057\u305f\u30bf\u30f3\u30cf\u309a\u30af\u8cea\u306f\u30b1\u3099\u30eb\u3068\u63a5\u89e6\u3057\u3066\u3044\u305f\u819c\u306e\u4e0a\u306b\u898b\u3048\u308b\u306f\u3059\u3099\u3066\u3099\u3059\u3002<strong>\u7591\u308f\u3057\u3044\u5834\u5408\u306f\u30d5\u3099\u30ed\u30c3\u30c8\u306b\u4e8c\u756a\u76ee\u306e\u300c\u30cf\u3099\u30c3\u30af\u30a2\u30c3\u30d5\u309a\u300d\u819c\u3092\u7528\u3044\u3001\u5f8c\u306b\u3053\u308c\u3092\u67d3\u8272\u3057\u3066\u30bf\u30f3\u30cf\u309a\u30af\u8cea\u304b\u30991\u679a\u76ee\u306e\u819c\u3092\u901a\u904e\u3057\u305f\u304b\u3068\u3099\u3046\u304b\u3092\u30c1\u30a7\u30c3\u30af\u3059\u308b\u3053\u3068\u304b\u3099\u3066\u3099\u304d\u307e\u3059\u3002<\/strong>\u30b1\u3099\u30eb\u306b\u30bf\u30f3\u30cf\u309a\u30af\u8cea\u304b\u3099\u6b8b\u308a\u3001\u819c\u3068\u306e\u7d50\u5408\u304b\u3099\u5f31\u3044\u5834\u5408\u306f\u4ee5\u4e0b\u306e\u30cf\u309a\u30e9\u30e1\u30fc\u30bf\u3092\u8abf\u6574\u3057\u307e\u3059\u3002<\/p>\n<h2>SDS\u3068\u30a2\u30eb\u30b3\u30fc\u30eb\u306e\u4f5c\u7528<\/h2>\n<p>\u305f\u3044\u3066\u3044\u306e\u30d5\u3099\u30ed\u30c3\u30c6\u30a3\u30f3\u30af\u3099\u30d5\u309a\u30ed\u30c8\u30b3\u30fc\u30eb\u3066\u3099\u306fSDS\u3068\u30a2\u30eb\u30b3\u30fc\u30eb\u304b\u3099\u7528\u3044\u3089\u308c\u3066\u3044\u307e\u3059\u3002\u3057\u304b\u3057\u3001\u3053\u308c\u3089\u306f\u8ee2\u5199\u306e\u6210\u5426\u306b\u95a2\u3057\u3066\u306f\u9006\u306e\u4f5c\u7528\u3092\u6709\u3057\u3066\u304a\u308a\u3001\u8ee2\u5199\u3055\u305b\u308b\u30bf\u30f3\u30cf\u309a\u30af\u8cea\u306e\u6027\u8cea\u306b\u5fdc\u3057\u3099\u3066\u6700\u9069\u5316\u3059\u308b\u5fc5\u8981\u304b\u3099\u3042\u308a\u307e\u3059\u3002<\/p>\n<p><strong>SDS\u306f\u30bf\u30f3\u30cf\u309a\u30af\u8cea\u304b\u3099\u79fb\u52d5\u3059\u308b\u305f\u3081\u306b\u5fc5\u8981\u3066\u3099\u3042\u308a\u3001\u30b1\u3099\u30eb\u304b\u3089\u306e\u5927\u304d\u306a\u30bf\u30f3\u30cf\u309a\u30af\u8cea\u306e\u8ee2\u5199\u3092\u4fc3\u9032\u3059\u308b\u4e0a\u3066\u3099\u3068\u304f\u306b\u6709\u7528\u3066\u3099\u3059\u3002<\/strong>\u3057\u304b\u3057\u3001\u819c\u3078\u306e\u7d50\u5408\u306f\u758e\u6c34\u6027\u306e\u76f8\u4e92\u4f5c\u7528\u3092\u5fc5\u8981\u3068\u3059\u308b\u306e\u3066\u3099\u3001SDS\u304b\u3099\u591a\u3059\u304d\u3099\u308b\u3068\u3068\u304f\u306b\u30cb\u30c8\u30ed\u30bb\u30eb\u30ed\u30fc\u30b9\u3078\u306e\u7d50\u5408\u304b\u3099\u59a8\u3051\u3099\u3089\u308c\u308b\u3053\u3068\u304b\u3099\u3042\u308a\u307e\u3059\u3002\u9006\u306b\u3042\u307e\u308a\u306b\u591a\u304f\u306eSDS\u304b\u3099\u30bf\u30f3\u30cf\u309a\u30af\u8cea\u304b\u3089\u596a\u308f\u308c\u308b\u3068\u30b1\u3099\u30eb\u304b\u3089\u8ee2\u5199\u3057\u306a\u3044\u3053\u3068\u304b\u3099\u3042\u308a\u307e\u3059\u3002<\/p>\n<p>\u4e00\u822c\u539f\u5247\u3068\u3057\u3066\u3001\u819c\u3078\u306e\u7d50\u5408\u52b9\u7387\u306f\u3088\u3044\u304b\u3099\u4e00\u90e8\u306e\u30bf\u30f3\u30cf\u309a\u30af\u8cea\u304b\u3099\u30b1\u3099\u30eb\u306b\u6b8b\u3063\u3066\u3044\u308b\u5834\u5408\u306f\u3001<strong>\u30c8\u30e9\u30f3\u30b9\u30d5\u30a1\u30fc\u30cf\u3099\u30c3\u30d5\u30a1\u30fc\u306b0.01%\u306eSDS\u3092\u6dfb\u52a0\u3059\u308b\u3068\u8ee2\u5199\u304b\u3099\u4fc3\u9032\u3055\u308c\u308b\u3053\u3068\u304b\u3099\u3042\u308a\u307e\u3059\u3002<\/strong>\u63a8\u5968\u30d5\u309a\u30ed\u30c8\u30b3\u30fc\u30eb\u3066\u3099\u306f\u30c8\u30e9\u30f3\u30b9\u30d5\u30a1\u30fc\u30cf\u3099\u30c3\u30d5\u30a1\u30fc\u306bSDS\u306f\u542b\u307e\u308c\u3066\u3044\u307e\u305b\u3093\u304b\u3099\u3001\u96fb\u6c17\u6cf3\u52d5\u5f8c\u306b\u30b1\u3099\u30eb\u3092\u6d78\u3055\u306a\u3044\u3053\u3068\u304b\u3099\u5fc5\u8981\u3066\u3099\u3059\u3002\u3064\u307e\u308a<strong>\u8ee2\u5199\u304b\u3099\u52b9\u7387\u7684\u306b\u884c\u306a\u308f\u308c\u308b\u305f\u3081\u306b\u306f\u30b1\u3099\u30eb\u306b\u6b8b\u5b58\u3057\u3066\u3044\u308bSDS\u3066\u3099\u5341\u5206<\/strong>\u306a\u306e\u3066\u3099\u3059\u3002<\/p>\n<p>\u4ed6\u65b9\u3001\u30a2\u30eb\u30b3\u30fc\u30eb\u306f\u30bf\u30f3\u30cf\u309a\u30af\u8cea\u304b\u3089\u4e00\u90e8\u306eSDS\u3092\u596a\u3046\u3053\u3068\u306b\u3088\u3063\u3066\u30bf\u30f3\u30cf\u309a\u30af\u8cea\u306e\u819c\u3078\u306e\u758e\u6c34\u6027\u7d50\u5408\u3092\u4fc3\u9032\u3059\u308b\u305f\u3081\u306b\u7528\u3044\u3089\u308c\u3066\u3044\u307e\u3059\u3002\u901a\u5e38\u3001<strong>\u30c8\u30e9\u30f3\u30b9\u30d5\u30a1\u30fc\u30cf\u3099\u30c3\u30d5\u30a1\u30fc\u306b20%\u306e\u30e1\u30bf\u30ce\u30fc\u30eb\u3092\u542b\u307e\u305b\u308b\u3053\u3068\u306b\u3088\u308a\u30cb\u30c8\u30ed\u30bb\u30eb\u30ed\u30fc\u30b9\u819c\u3078\u306e\u7d50\u5408\u304b\u3099\u5411\u4e0a\u3057\u307e\u3059\u3002<\/strong><\/p>\n<h2>\u30b1\u3099\u30eb\u306e\u30a2\u30af\u30ea\u30eb\u30a2\u30df\u30c8\u3099\u306e\u6fc3\u5ea6<\/h2>\n<p><strong>\u30a2\u30af\u30ea\u30eb\u30a2\u30df\u30c8\u3099\u306e\u6fc3\u5ea6\u304b\u3099\u4f4e\u3044\u307b\u3068\u3099\u30bf\u30f3\u30cf\u309a\u30af\u8cea\u306f\u8ee2\u5199\u3057\u3084\u3059\u304f\u306a\u308a\u307e\u3059\u3002<\/strong>\u30bf\u30f3\u30cf\u309a\u30af\u8cea\u3092\u5206\u96e2\u3059\u308b\u4e0a\u3066\u3099\u3066\u3099\u304d\u308b\u305f\u3099\u3051\u4f4e\u3044\u6fc3\u5ea6\u3092\u9078\u629e\u3057\u307e\u3059\u3002\u30af\u3099\u30e9\u30b7\u3099\u30a8\u30f3\u30c8\u30b1\u3099\u30eb\u306f\u30b1\u3099\u30eb\u30de\u30c8\u30ea\u30c3\u30af\u30b9\u306e\u591a\u5b54\u6027\u304b\u3099\u3055\u307e\u3055\u3099\u307e\u306a\u5927\u304d\u3055\u306e\u30bf\u30f3\u30cf\u309a\u30af\u8cea\u306b\u3088\u304f\u9069\u5408\u3057\u3066\u3044\u308b\u306e\u3066\u3099\u3001\u5e83\u7bc4\u306a\u5927\u304d\u3055\u306e\u30bf\u30f3\u30cf\u309a\u30af\u8cea\u3092\u30d5\u3099\u30ed\u30c3\u30c8\u3059\u308b\u4e0a\u3066\u3099\u7406\u60f3\u7684\u3066\u3099\u3059\u3002<\/p>\n<h2>\u30b1\u3099\u30eb\u306e\u539a\u3055<\/h2>\n<p>\u4ed6\u306e\u3059\u3078\u3099\u3066\u306e\u6761\u4ef6\u304b\u3099\u540c\u3057\u3099\u3066\u3099\u3042\u308c\u306f\u3099\u3001<strong>\u30b1\u3099\u30eb\u304b\u3099\u8584\u3044\u307b\u3068\u3099\u30bf\u30f3\u30cf\u309a\u30af\u8cea\u306f\u5bb9\u6613\u306b\u8ee2\u5199\u3055\u308c\u307e\u3059\u3002<\/strong>\u3057\u305f\u304b\u3099\u3063\u3066\u3001\u30b5\u30f3\u30d5\u309a\u30eb\u5bb9\u91cf\u304b\u3099\u8a31\u3059\u9650\u308a\u539a\u30551.5 mm\u3088\u308a1.0 mm\u306e\u30b1\u3099\u30eb\u3092\u9078\u629e\u3057\u307e\u3059\u3002<\/p>\n<h2>\u96fb\u5834(\u96fb\u5727\u00d7\u6642\u9593)<\/h2>\n<p><strong>\u96fb\u5727\u304b\u3099\u4f4e\u3059\u304d\u3099\u305f\u308a\u8ee2\u5199\u6642\u9593\u304b\u3099\u77ed\u3059\u304d\u3099\u308b\u3068\u4e00\u90e8\u306e\u30bf\u30f3\u30cf\u309a\u30af\u8cea\u304b\u3099\u30b1\u3099\u30eb\u306b\u6b8b\u308a\u307e\u3059\u3002\u96fb\u5727\u304b\u3099\u9ad8\u3059\u304d\u3099\u308b\u3068\u5c0f\u3055\u306a\u30bf\u30f3\u30cf\u309a\u30af\u8cea\u306f\u7d50\u5408\u3059\u308b\u524d\u306b\u819c\u3092\u901a\u904e\u3057\u3066\u3057\u307e\u3044\u307e\u3059\u3002<\/strong>\u63a8\u5968\u6761\u4ef6\u3066\u3099\u30d5\u3099\u30ed\u30c3\u30c6\u30a3\u30f3\u30af\u3099\u3057\u305f\u5f8c\u306b\u30b1\u3099\u30eb\u306b\u30bf\u30f3\u30cf\u309a\u30af\u8cea\u304b\u3099\u6b8b\u308b\u5834\u5408\u306f\u30015\u30db\u3099\u30eb\u30c8\u3092\u8d85\u3048\u306a\u3044\u7a0b\u5ea6\u306e\u96fb\u5727\u3092\u4e0a\u3051\u3099\u308b\u306e\u304b\u3099\u6709\u52b9\u3066\u3099\u3059\u3002\u3057\u304b\u3057\u3001\u3044\u3063\u305f\u3093SDS\u304b\u3099\u30bf\u30f3\u30cf\u309a\u30af\u8cea\u304b\u3089\u5916\u308c\u308b\u3068\u8ee2\u5199\u6642\u9593\u3092\u9577\u304f\u3057\u3066\u3082\u96fb\u5727\u3092\u4e0a\u3051\u3099\u3066\u3082\u52b9\u679c\u304b\u3099\u306a\u3044\u3053\u3068\u306b\u6ce8\u610f\u3057\u3066\u4e0b\u3055\u3044\u3002\u305f\u3044\u3066\u3044\u306e\u30bf\u30f3\u30cf\u309a\u30af\u8cea\u306f\u3044\u3063\u305f\u3093\u7d50\u5408\u3059\u308b\u3068\u8ee2\u5199\u6642\u9593\u3092\u4f38\u306f\u3099\u3057\u3066\u3082\u819c\u4e0a\u306b\u7559\u307e\u308a\u307e\u3059\u3002<\/p>\n<h2>\u819c\u306e\u7a2e\u985e<\/h2>\n<p>\u30cb\u30c8\u30ed\u30bb\u30eb\u30ed\u30fc\u30b9\u819c\u3078\u306e\u7d50\u5408\u306f\u4e3b\u306b\u758e\u6c34\u6027\u7d50\u5408\u306b\u3088\u308b\u3082\u306e\u3066\u3099\u3059\u3002<strong>\u30cb\u30c8\u30ed\u30bb\u30eb\u30ed\u30fc\u30b9\u306f\u591a\u76ee\u7684\u306e\u3059\u304f\u3099\u308c\u305f\u819c\u3066\u3099\u3059\u3002\u5c0f\u3055\u306a\u30d8\u309a\u30d5\u309a\u30c1\u30c8\u3099\u3066\u3099\u306f\u5b54\u306e\u5c0f\u3055\u306a\u819c\u3092\u304a\u85a6\u3081\u3057\u307e\u3059\u3002<\/strong><\/p>\n<p>PVDF\u306f\u30cb\u30c8\u30ed\u30bb\u30eb\u30ed\u30fc\u30b9\u3088\u308a\u758e\u6c34\u6027\u304b\u3099\u9ad8\u304f\u3001\u3088\u308a\u5f37\u529b\u306b\u30bf\u30f3\u30cf\u309a\u30af\u8cea\u3068\u7d50\u5408\u3057\u3001\u30d5\u3099\u30ed\u30c3\u30c6\u30a3\u30f3\u30af\u3099\u7cfb\u3066\u3099\u306f\u3088\u308a\u591a\u304f\u306eSDS\u306b\u8010\u3048\u307e\u3059\u3002\u3057\u305f\u304b\u3099\u3063\u3066\u3001<strong>\u4e00\u822c\u306bPVDF\u306f\u30cb\u30c8\u30ed\u30bb\u30eb\u30ed\u30fc\u30b9\u3088\u308a\u53b3\u683c\u306a\u30d5\u3099\u30ed\u30c3\u30ad\u30f3\u30af\u3099\u6761\u4ef6\u3092\u5fc5\u8981\u3068\u3057\u307e\u3059\u3002<\/strong>PVDF\u306f\u30bf\u30f3\u30cf\u309a\u30af\u8cea\u306e\u914d\u5217\u6c7a\u5b9a\u306b\u9069\u3057\u3066\u3044\u307e\u3059\u3002<\/p>\n<h1>\u3010\u7121\u6599\u30c0\u30a6\u30f3\u30ed\u30fc\u30c9\u3011\u30bf\u30f3\u30d1\u30af\u8cea\u89e3\u6790\u30ef\u30fc\u30af\u30d5\u30ed\u30fc\u30cf\u30f3\u30c9\u30d6\u30c3\u30af<\/h1>\n<p>\u52b9\u7387\u7684\u306a\u30bf\u30f3\u30d1\u30af\u8cea\u62bd\u51fa\u304b\u3089\u30a6\u30a7\u30b9\u30bf\u30f3\u30d6\u30ed\u30c3\u30c6\u30a3\u30f3\u30b0\u306e\u89e3\u6790\u30c4\u30fc\u30eb\u307e\u3067\u3001\u5305\u62ec\u7684\u306b\u30bd\u30ea\u30e5\u30fc\u30b7\u30e7\u30f3\u3092\u7d39\u4ecb\u3057\u3066\u304a\u308a\u307e\u3059\u3002PDF\u30d5\u30a1\u30a4\u30eb\u306e\u30c0\u30a6\u30f3\u30ed\u30fc\u30c9\u3092\u3054\u5e0c\u671b\u306e\u65b9\u306f\u3001\u4e0b\u8a18\u30dc\u30bf\u30f3\u3088\u308a\u304a\u7533\u8fbc\u307f\u304f\u3060\u3055\u3044\u3002<\/p>\n<p><a class=\"btn btn-red\" href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/global\/forms\/catalogs-protein-form.html?CID=bid_pca_sbu_r04_jp_cp0000_pjt0000_bid00000_0so_blg_op_awa_oc_s00_pa10_Social_LAB\" target=\"_blank\" rel=\"noopener\">\u30c0\u30a6\u30f3\u30ed\u30fc\u30c9\u3059\u308b<\/a><\/p>\n<p>&nbsp;<\/p>\n<p>\u7814\u7a76\u7528\u306b\u306e\u307f\u4f7f\u7528\u3067\u304d\u307e\u3059\u3002\u8a3a\u65ad\u76ee\u7684\u304a\u3088\u3073\u305d\u306e\u624b\u7d9a\u304d\u4e0a\u3067\u306e\u4f7f\u7528\u306f\u3067\u304d\u307e\u305b\u3093\u3002<\/p>\n","protected":false},"excerpt":{"rendered":"<p>SDS\u30b1\u3099\u30eb\u304b\u3089\u306e\u30bf\u30f3\u30cf\u309a\u30af\u8cea\u306e\u96fb\u6c17\u30d5\u3099\u30ed\u30c3\u30c6\u30a3\u30f3\u30af\u3099\u3092\u6700\u9069\u5316\u3059\u308b\u305f\u3081\u306b\u306f\u6570\u591a\u304f\u306e\u30cf\u309a\u30e9\u30e1\u30fc\u30bf\u3092\u8003\u616e\u3059\u308b\u5fc5\u8981\u304b\u3099\u3042\u308a\u307e\u3059\u3002\u76ee\u6a19\u306f\u30b1\u3099\u30eb\u304b\u3089\u3059\u3078\u3099\u3066\u306e\u30bf\u30f3\u30cf\u309a\u30af\u8cea\u3092\u8ee2\u5199\u3055\u305b\u3001\u8ee2\u5199\u819c\u306b\u5b9a\u91cf\u7684\u306b\u8ee2\u5199\u3055\u305b\u308b\u3053\u3068\u3066\u3099\u3059\u3002\u4eca\u56de\u306f\u3001\u30a6\u30a7\u30b9\u30bf\u30f3\u30d6\u30ed\u30c3\u30c6\u30a3\u30f3\u30b0\u306b\u304a\u3051\u308b\u8ee2\u5199\u306e\u6700\u9069\u5316\u65b9\u6cd5\u3092\u3054\u7d39\u4ecb\u3057\u307e\u3059\u3002<\/p>\n","protected":false},"author":988,"featured_media":2774,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_monsterinsights_skip_tracking":false,"_genesis_hide_title":false,"_genesis_hide_breadcrumbs":false,"_genesis_hide_singular_image":false,"_genesis_hide_footer_widgets":false,"_genesis_custom_body_class":"","_genesis_custom_post_class":"","_genesis_layout":"","_jetpack_newsletter_access":"","_jetpack_dont_email_post_to_subs":false,"_jetpack_newsletter_tier_id":0,"_jetpack_memberships_contains_paywalled_content":false,"_jetpack_feature_clip_id":0,"_jetpack_memberships_contains_paid_content":false,"footnotes":"","jetpack_post_was_ever_published":false},"categories":[156],"tags":[17],"division":[],"class_list":["post-487","post","type-post","status-publish","format-standard","has-post-thumbnail","category-mol-bio","tag-western-blotting","entry"],"_selected_authors":"","_selected_reviewers":"","acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v27.8 (Yoast SEO v27.8) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>\u30a6\u30a7\u30b9\u30bf\u30f3\u30d6\u30ed\u30c3\u30c6\u30a3\u30f3\u30b0\u306b\u304a\u3051\u308b\u8ee2\u5199\u52b9\u7387\u306e\u6700\u9069\u5316 - Learning at the Bench<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/optimizing-western-blot-transfer\/\" \/>\n<meta property=\"og:locale\" content=\"ja_JP\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"\u30a6\u30a7\u30b9\u30bf\u30f3\u30d6\u30ed\u30c3\u30c6\u30a3\u30f3\u30b0\u306b\u304a\u3051\u308b\u8ee2\u5199\u52b9\u7387\u306e\u6700\u9069\u5316\" \/>\n<meta property=\"og:description\" content=\"SDS\u30b1\u3099\u30eb\u304b\u3089\u306e\u30bf\u30f3\u30cf\u309a\u30af\u8cea\u306e\u96fb\u6c17\u30d5\u3099\u30ed\u30c3\u30c6\u30a3\u30f3\u30af\u3099\u3092\u6700\u9069\u5316\u3059\u308b\u305f\u3081\u306b\u306f\u6570\u591a\u304f\u306e\u30cf\u309a\u30e9\u30e1\u30fc\u30bf\u3092\u8003\u616e\u3059\u308b\u5fc5\u8981\u304b\u3099\u3042\u308a\u307e\u3059\u3002\u76ee\u6a19\u306f\u30b1\u3099\u30eb\u304b\u3089\u3059\u3078\u3099\u3066\u306e\u30bf\u30f3\u30cf\u309a\u30af\u8cea\u3092\u8ee2\u5199\u3055\u305b\u3001\u8ee2\u5199\u819c\u306b\u5b9a\u91cf\u7684\u306b\u8ee2\u5199\u3055\u305b\u308b\u3053\u3068\u3066\u3099\u3059\u3002\u4eca\u56de\u306f\u3001\u30a6\u30a7\u30b9\u30bf\u30f3\u30d6\u30ed\u30c3\u30c6\u30a3\u30f3\u30b0\u306b\u304a\u3051\u308b\u8ee2\u5199\u306e\u6700\u9069\u5316\u65b9\u6cd5\u3092\u3054\u7d39\u4ecb\u3057\u307e\u3059\u3002\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/optimizing-western-blot-transfer\/\" \/>\n<meta property=\"og:site_name\" content=\"Learning at the Bench\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/ThermoFisherJapan\" \/>\n<meta property=\"article:published_time\" content=\"2016-09-27T00:00:00+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2025-01-22T05:51:20+00:00\" \/>\n<meta property=\"og:image\" content=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/enhancing-western-blot-signals-title-3.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"1200\" \/>\n\t<meta property=\"og:image:height\" content=\"630\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"LATB Staff\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:creator\" content=\"@ThermoFisherJP\" \/>\n<meta name=\"twitter:site\" content=\"@ThermoFisherJP\" \/>\n<meta name=\"twitter:label1\" content=\"\u57f7\u7b46\u8005\" \/>\n\t<meta name=\"twitter:data1\" content=\"LATB Staff\" \/>\n\t<meta name=\"twitter:label2\" content=\"\u63a8\u5b9a\u8aad\u307f\u53d6\u308a\u6642\u9593\" \/>\n\t<meta name=\"twitter:data2\" content=\"6\u5206\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/optimizing-western-blot-transfer\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/optimizing-western-blot-transfer\\\/\"},\"author\":{\"name\":\"LATB Staff\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#\\\/schema\\\/person\\\/201e6a5abb838fa34e8ff0174b015d36\"},\"headline\":\"\u30a6\u30a7\u30b9\u30bf\u30f3\u30d6\u30ed\u30c3\u30c6\u30a3\u30f3\u30b0\u306b\u304a\u3051\u308b\u8ee2\u5199\u52b9\u7387\u306e\u6700\u9069\u5316\",\"datePublished\":\"2016-09-27T00:00:00+00:00\",\"dateModified\":\"2025-01-22T05:51:20+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/optimizing-western-blot-transfer\\\/\"},\"wordCount\":19,\"commentCount\":0,\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/optimizing-western-blot-transfer\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2019\\\/07\\\/enhancing-western-blot-signals-title-3.jpg\",\"keywords\":[\"\u30a6\u30a7\u30b9\u30bf\u30f3\u30d6\u30ed\u30c3\u30c6\u30a3\u30f3\u30b0\"],\"articleSection\":[\"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023\"],\"inLanguage\":\"ja\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/optimizing-western-blot-transfer\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/optimizing-western-blot-transfer\\\/\",\"url\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/optimizing-western-blot-transfer\\\/\",\"name\":\"\u30a6\u30a7\u30b9\u30bf\u30f3\u30d6\u30ed\u30c3\u30c6\u30a3\u30f3\u30b0\u306b\u304a\u3051\u308b\u8ee2\u5199\u52b9\u7387\u306e\u6700\u9069\u5316 - Learning at the Bench\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/optimizing-western-blot-transfer\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/optimizing-western-blot-transfer\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2019\\\/07\\\/enhancing-western-blot-signals-title-3.jpg\",\"datePublished\":\"2016-09-27T00:00:00+00:00\",\"dateModified\":\"2025-01-22T05:51:20+00:00\",\"author\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#\\\/schema\\\/person\\\/201e6a5abb838fa34e8ff0174b015d36\"},\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/optimizing-western-blot-transfer\\\/#breadcrumb\"},\"inLanguage\":\"ja\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/optimizing-western-blot-transfer\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"ja\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/optimizing-western-blot-transfer\\\/#primaryimage\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2019\\\/07\\\/enhancing-western-blot-signals-title-3.jpg\",\"contentUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2019\\\/07\\\/enhancing-western-blot-signals-title-3.jpg\",\"width\":1200,\"height\":630,\"caption\":\"enhancing-western-blot-signals-title\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/optimizing-western-blot-transfer\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"\u30a6\u30a7\u30b9\u30bf\u30f3\u30d6\u30ed\u30c3\u30c6\u30a3\u30f3\u30b0\u306b\u304a\u3051\u308b\u8ee2\u5199\u52b9\u7387\u306e\u6700\u9069\u5316\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#website\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/\",\"name\":\"Learning at the Bench\",\"description\":\"\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"ja\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#\\\/schema\\\/person\\\/201e6a5abb838fa34e8ff0174b015d36\",\"name\":\"LATB Staff\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"ja\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/8803277856c8b753feb4217dff0f9953327452df1a615c3c88b2f9864efb2ddd?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/8803277856c8b753feb4217dff0f9953327452df1a615c3c88b2f9864efb2ddd?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/8803277856c8b753feb4217dff0f9953327452df1a615c3c88b2f9864efb2ddd?s=96&d=mm&r=g\",\"caption\":\"LATB Staff\"},\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/author\\\/latbstaff\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"\u30a6\u30a7\u30b9\u30bf\u30f3\u30d6\u30ed\u30c3\u30c6\u30a3\u30f3\u30b0\u306b\u304a\u3051\u308b\u8ee2\u5199\u52b9\u7387\u306e\u6700\u9069\u5316 - Learning at the Bench","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/optimizing-western-blot-transfer\/","og_locale":"ja_JP","og_type":"article","og_title":"\u30a6\u30a7\u30b9\u30bf\u30f3\u30d6\u30ed\u30c3\u30c6\u30a3\u30f3\u30b0\u306b\u304a\u3051\u308b\u8ee2\u5199\u52b9\u7387\u306e\u6700\u9069\u5316","og_description":"SDS\u30b1\u3099\u30eb\u304b\u3089\u306e\u30bf\u30f3\u30cf\u309a\u30af\u8cea\u306e\u96fb\u6c17\u30d5\u3099\u30ed\u30c3\u30c6\u30a3\u30f3\u30af\u3099\u3092\u6700\u9069\u5316\u3059\u308b\u305f\u3081\u306b\u306f\u6570\u591a\u304f\u306e\u30cf\u309a\u30e9\u30e1\u30fc\u30bf\u3092\u8003\u616e\u3059\u308b\u5fc5\u8981\u304b\u3099\u3042\u308a\u307e\u3059\u3002\u76ee\u6a19\u306f\u30b1\u3099\u30eb\u304b\u3089\u3059\u3078\u3099\u3066\u306e\u30bf\u30f3\u30cf\u309a\u30af\u8cea\u3092\u8ee2\u5199\u3055\u305b\u3001\u8ee2\u5199\u819c\u306b\u5b9a\u91cf\u7684\u306b\u8ee2\u5199\u3055\u305b\u308b\u3053\u3068\u3066\u3099\u3059\u3002\u4eca\u56de\u306f\u3001\u30a6\u30a7\u30b9\u30bf\u30f3\u30d6\u30ed\u30c3\u30c6\u30a3\u30f3\u30b0\u306b\u304a\u3051\u308b\u8ee2\u5199\u306e\u6700\u9069\u5316\u65b9\u6cd5\u3092\u3054\u7d39\u4ecb\u3057\u307e\u3059\u3002","og_url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/optimizing-western-blot-transfer\/","og_site_name":"Learning at the Bench","article_publisher":"https:\/\/www.facebook.com\/ThermoFisherJapan","article_published_time":"2016-09-27T00:00:00+00:00","article_modified_time":"2025-01-22T05:51:20+00:00","og_image":[{"width":1200,"height":630,"url":"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/enhancing-western-blot-signals-title-3.jpg","type":"image\/jpeg"}],"author":"LATB Staff","twitter_card":"summary_large_image","twitter_creator":"@ThermoFisherJP","twitter_site":"@ThermoFisherJP","twitter_misc":{"\u57f7\u7b46\u8005":"LATB Staff","\u63a8\u5b9a\u8aad\u307f\u53d6\u308a\u6642\u9593":"6\u5206"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/optimizing-western-blot-transfer\/#article","isPartOf":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/optimizing-western-blot-transfer\/"},"author":{"name":"LATB Staff","@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#\/schema\/person\/201e6a5abb838fa34e8ff0174b015d36"},"headline":"\u30a6\u30a7\u30b9\u30bf\u30f3\u30d6\u30ed\u30c3\u30c6\u30a3\u30f3\u30b0\u306b\u304a\u3051\u308b\u8ee2\u5199\u52b9\u7387\u306e\u6700\u9069\u5316","datePublished":"2016-09-27T00:00:00+00:00","dateModified":"2025-01-22T05:51:20+00:00","mainEntityOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/optimizing-western-blot-transfer\/"},"wordCount":19,"commentCount":0,"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/optimizing-western-blot-transfer\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/enhancing-western-blot-signals-title-3.jpg","keywords":["\u30a6\u30a7\u30b9\u30bf\u30f3\u30d6\u30ed\u30c3\u30c6\u30a3\u30f3\u30b0"],"articleSection":["\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023"],"inLanguage":"ja","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/optimizing-western-blot-transfer\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/optimizing-western-blot-transfer\/","url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/optimizing-western-blot-transfer\/","name":"\u30a6\u30a7\u30b9\u30bf\u30f3\u30d6\u30ed\u30c3\u30c6\u30a3\u30f3\u30b0\u306b\u304a\u3051\u308b\u8ee2\u5199\u52b9\u7387\u306e\u6700\u9069\u5316 - Learning at the Bench","isPartOf":{"@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/optimizing-western-blot-transfer\/#primaryimage"},"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/optimizing-western-blot-transfer\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/enhancing-western-blot-signals-title-3.jpg","datePublished":"2016-09-27T00:00:00+00:00","dateModified":"2025-01-22T05:51:20+00:00","author":{"@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#\/schema\/person\/201e6a5abb838fa34e8ff0174b015d36"},"breadcrumb":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/optimizing-western-blot-transfer\/#breadcrumb"},"inLanguage":"ja","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/optimizing-western-blot-transfer\/"]}]},{"@type":"ImageObject","inLanguage":"ja","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/optimizing-western-blot-transfer\/#primaryimage","url":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/enhancing-western-blot-signals-title-3.jpg","contentUrl":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/enhancing-western-blot-signals-title-3.jpg","width":1200,"height":630,"caption":"enhancing-western-blot-signals-title"},{"@type":"BreadcrumbList","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/optimizing-western-blot-transfer\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/"},{"@type":"ListItem","position":2,"name":"\u30a6\u30a7\u30b9\u30bf\u30f3\u30d6\u30ed\u30c3\u30c6\u30a3\u30f3\u30b0\u306b\u304a\u3051\u308b\u8ee2\u5199\u52b9\u7387\u306e\u6700\u9069\u5316"}]},{"@type":"WebSite","@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#website","url":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/","name":"Learning at the Bench","description":"","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"ja"},{"@type":"Person","@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#\/schema\/person\/201e6a5abb838fa34e8ff0174b015d36","name":"LATB Staff","image":{"@type":"ImageObject","inLanguage":"ja","@id":"https:\/\/secure.gravatar.com\/avatar\/8803277856c8b753feb4217dff0f9953327452df1a615c3c88b2f9864efb2ddd?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/8803277856c8b753feb4217dff0f9953327452df1a615c3c88b2f9864efb2ddd?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/8803277856c8b753feb4217dff0f9953327452df1a615c3c88b2f9864efb2ddd?s=96&d=mm&r=g","caption":"LATB Staff"},"url":"https:\/\/admin.acceleratingscience.com\/author\/latbstaff\/"}]}},"taxonomy_info":{"category":[{"value":156,"label":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023"}],"post_tag":[{"value":17,"label":"\u30a6\u30a7\u30b9\u30bf\u30f3\u30d6\u30ed\u30c3\u30c6\u30a3\u30f3\u30b0"}]},"featured_image_src_large":["https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/enhancing-western-blot-signals-title-3-1024x538.jpg",760,399,true],"author_info":{"display_name":"LATB Staff","author_link":"https:\/\/admin.acceleratingscience.com\/author\/latbstaff\/"},"comment_info":0,"category_info":[{"term_id":156,"name":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","slug":"mol-bio","term_group":0,"term_taxonomy_id":156,"taxonomy":"category","description":"","parent":0,"count":540,"filter":"raw","meta":[],"cat_ID":156,"category_count":540,"category_description":"","cat_name":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","category_nicename":"mol-bio","category_parent":0}],"tag_info":[{"term_id":17,"name":"\u30a6\u30a7\u30b9\u30bf\u30f3\u30d6\u30ed\u30c3\u30c6\u30a3\u30f3\u30b0","slug":"western-blotting","term_group":0,"term_taxonomy_id":17,"taxonomy":"post_tag","description":"","parent":0,"count":27,"filter":"raw","meta":[]}],"jetpack-related-posts":[{"id":24108,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/cell-culture-cell-count-bid-ts-mbr-25065-2\/","url_meta":{"origin":487,"position":0},"title":"\u3010\u7b2c6\u56de\u3011 \u30a6\u30a7\u30b9\u30bf\u30f3\u30d6\u30ed\u30c3\u30c6\u30a3\u30f3\u30b0\u6cd5\u306b\u3088\u308b \u300e\u30a8\u30af\u30bd\u30bd\u30fc\u30e0\u4e2d\u306e\u30bf\u30f3\u30d1\u30af\u8cea\uff08Protein cargo\uff09\u300f\u306e\u89e3\u6790","author":"LatB Staff","date":"2026\u5e747\u670815\u65e5","format":false,"excerpt":"\u30a8\u30af\u30bd\u30bd\u30fc\u30e0\uff08\u30a8\u30ad\u30bd\u30bd\u30fc\u30e0\uff09\u306f\u3001\u7d30\u80de\u304b\u3089\u5206\u6ccc\u3055\u308c\u308b\u5c0f\u3055\u306a\u819c\u5c0f\u80de\u3067\u3001\u6838\u9178\uff08RNA\uff0fDNA\uff09\u3060\u3051\u3067\u306a\u304f\u3001\u2026","rel":"","context":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","block_context":{"text":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/mol-bio\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/11\/cell-culture-cell-count-bid-ts-mbr-25065_eyecatch.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/11\/cell-culture-cell-count-bid-ts-mbr-25065_eyecatch.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/11\/cell-culture-cell-count-bid-ts-mbr-25065_eyecatch.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/11\/cell-culture-cell-count-bid-ts-mbr-25065_eyecatch.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/11\/cell-culture-cell-count-bid-ts-mbr-25065_eyecatch.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/11\/cell-culture-cell-count-bid-ts-mbr-25065_eyecatch.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":25472,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/exosome-ts-r-25067\/","url_meta":{"origin":487,"position":1},"title":"\u3010\u7b2c7\u56de\u3011 \u30a8\u30af\u30bd\u30bd\u30fc\u30e0\u30b5\u30d6\u30bf\u30a4\u30d7\u306e\u5206\u753b\u306e\u6982\u8981","author":"LatB Staff","date":"2026\u5e748\u670813\u65e5","format":false,"excerpt":"\u7d30\u80de\u304c\u5206\u6ccc\u3059\u308b\u7d30\u80de\u5916\u5c0f\u80de\u306e\u4e2d\u3067\u3082\u3001\u30a8\u30af\u30bd\u30bd\u30fc\u30e0\u306f\u305d\u306e\u60c5\u5831\u4f1d\u9054\u6a5f\u80fd\u3084\u75be\u60a3\u3068\u306e\u95a2\u9023\u6027\u304b\u3089\u6ce8\u76ee\u3092\u96c6\u3081\u3066\u3044\u307e\u2026","rel":"","context":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","block_context":{"text":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/mol-bio\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25019_eyecatch.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25019_eyecatch.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25019_eyecatch.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25019_eyecatch.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25019_eyecatch.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25019_eyecatch.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":25565,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/exosome-antibody-ts-r-25068\/","url_meta":{"origin":487,"position":2},"title":"\u3010\u7b2c8\u56de\u3011\u30a8\u30af\u30bd\u30bd\u30fc\u30e0\u30b5\u30d6\u30bf\u30a4\u30d7\u306e\u5206\u753b\u6cd5 \uff1a \u30a6\u30a7\u30b9\u30bf\u30f3\u30d6\u30ed\u30c3\u30c8\uff0fqRT-PCR\uff0f\u30b7\u30fc\u30b1\u30f3\u30b9\u89e3\u6790\u306b\u9069\u3057\u305f\u5206\u753b\u65b9\u6cd5","author":"LatB Staff","date":"2026\u5e749\u670829\u65e5","format":false,"excerpt":"\u672c\u7a3f\u3067\u306f\u3001\u30a8\u30af\u30bd\u30bd\u30fc\u30e0\u819c\u4e0a\u306e\u7279\u5b9a\u306e\u30bf\u30f3\u30d1\u30af\u8cea\u3092\u6a19\u7684\u3068\u3057\u305f\u514d\u75ab\u5438\u7740\u6cd5\u306b\u57fa\u3065\u304f\u5206\u753b\u624b\u6cd5\u3092\u7d39\u4ecb\u3057\u307e\u3059\u3002\u30a8\u30af\u2026","rel":"","context":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","block_context":{"text":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/mol-bio\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25019_eyecatch.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25019_eyecatch.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25019_eyecatch.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25019_eyecatch.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25019_eyecatch.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25019_eyecatch.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":24606,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/transfection-antibody-bid-ts-mbr-26004\/","url_meta":{"origin":487,"position":3},"title":"\u7d30\u80de\u5185\u30bf\u30f3\u30d1\u30af\u8cea\u9664\u53bb\u30b7\u30b9\u30c6\u30e0\uff08Trim-Away\u6cd5\uff09\u306e\u7d39\u4ecb\uff5e\u30a8\u30ec\u30af\u30c8\u30ed\u30dd\u30ec\u30fc\u30b7\u30e7\u30f3\u6a5f\u5668\u3092\u4f7f\u7528\u3057\u3066\uff5e","author":"LatB Staff","date":"2026\u5e742\u67084\u65e5","format":false,"excerpt":"2018\u5e74\u306e\u6587\u732e(1)\u3067\u7d30\u80de\u5185\u306e\u5185\u5728\u6027\u30bf\u30f3\u30d1\u30af\u8cea\u3092\u76f4\u63a5\u5206\u89e3\u3059\u308b\u3001Trim-Away\u6cd5\u304c\u7d39\u4ecb\u3055\u308c\u307e\u3057\u305f\u2026","rel":"","context":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","block_context":{"text":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/mol-bio\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/01\/transfection-antibody-bid-ts-mbr-26004_eyecatch.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/01\/transfection-antibody-bid-ts-mbr-26004_eyecatch.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/01\/transfection-antibody-bid-ts-mbr-26004_eyecatch.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/01\/transfection-antibody-bid-ts-mbr-26004_eyecatch.jpg?resize=700%2C400&ssl=1 2x"},"classes":[]},{"id":20124,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/exosome-gene-therapy-ts-r-25015\/","url_meta":{"origin":487,"position":4},"title":"\u3010\u7b2c1\u56de\u3011Exosome\uff08\u30a8\u30af\u30bd\u30bd\u30fc\u30e0\uff0f\u30a8\u30ad\u30bd\u30bd\u30fc\u30e0\uff09\u3068\u306f\uff1f","author":"LatB Staff","date":"2026\u5e744\u670815\u65e5","format":false,"excerpt":"Exosome\uff08\u30a8\u30af\u30bd\u30bd\u30fc\u30e0\uff0f\u30a8\u30ad\u30bd\u30bd\u30fc\u30e0\uff09\u306e\u7814\u7a76\u304c\u6ce8\u76ee\u3092\u96c6\u3081\u3066\u3044\u307e\u3059\u3002\u8208\u5473\u306f\u3042\u3063\u3066\u3082\u3001\u3069\u306e\u3088\u3046\u306b\u7814\u2026","rel":"","context":"\u305d\u306e\u4ed6","block_context":{"text":"\u305d\u306e\u4ed6","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/else\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/03\/6fae859c8c1eacdaa39f3ae843ae1bda-scaled.png?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/03\/6fae859c8c1eacdaa39f3ae843ae1bda-scaled.png?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/03\/6fae859c8c1eacdaa39f3ae843ae1bda-scaled.png?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/03\/6fae859c8c1eacdaa39f3ae843ae1bda-scaled.png?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/03\/6fae859c8c1eacdaa39f3ae843ae1bda-scaled.png?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/03\/6fae859c8c1eacdaa39f3ae843ae1bda-scaled.png?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":25325,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/exosome-gene-expression-ts-r-25019\/","url_meta":{"origin":487,"position":5},"title":"\u3010\u7b2c5\u56de\u3011 &#8220;RNA cargo&#8221;\u306e\u7cbe\u88fd\u3068\u5b9a\u91cf\u89e3\u6790\u300d\uff5emRNA\u306e\u5b9a\u91cf\u89e3\u6790\uff5e","author":"LatB Staff","date":"2026\u5e746\u670811\u65e5","format":false,"excerpt":"\u4eca\u56de\u306f\u3001\u30a8\u30af\u30bd\u30bd\u30fc\u30e0\uff08\u30a8\u30ad\u30bd\u30bd\u30fc\u30e0\uff09\u4e2d\u306emRNA\u306e\u5b9a\u91cf\u89e3\u6790\u306b\u3064\u3044\u3066\u8aac\u660e\u3057\u307e\u3059\u3002\u7b2c3\u56de\u3067\u30a8\u30af\u30bd\u30bd\u30fc\u30e0\u304b\u2026","rel":"","context":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","block_context":{"text":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/mol-bio\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25018_eyecatch-1.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25018_eyecatch-1.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25018_eyecatch-1.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25018_eyecatch-1.jpg?resize=700%2C400&ssl=1 2x"},"classes":[]}],"jetpack_sharing_enabled":true,"amp_enabled":true,"jetpack_featured_media_url":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/enhancing-western-blot-signals-title-3.jpg","_links":{"self":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/posts\/487","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/users\/988"}],"replies":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/comments?post=487"}],"version-history":[{"count":0,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/posts\/487\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/media\/2774"}],"wp:attachment":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/media?parent=487"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/categories?post=487"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/tags?post=487"},{"taxonomy":"division","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/division?post=487"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}