{"id":495,"date":"2016-10-18T00:00:00","date_gmt":"2016-10-18T00:00:00","guid":{"rendered":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/cell-culture-environment\/"},"modified":"2025-02-26T15:56:41","modified_gmt":"2025-02-26T06:56:41","slug":"cell-culture-environment","status":"publish","type":"post","link":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/cell-culture-environment\/","title":{"rendered":"\uff11\u304b\u3089\u5206\u304b\u308b\u7d30\u80de\u57f9\u990a\u306b\u304a\u3051\u308b\u57f9\u990a\u74b0\u5883"},"content":{"rendered":"<h2>\u306f\u3058\u3081\u306b<\/h2>\n<p><strong>\u7d30\u80de\u57f9\u990a\u306e\u5927\u304d\u306a\u5229\u70b9\u306e\u4e00\u3064\u306f\u3001\u7d30\u80de\u304c\u5897\u6b96\u3059\u308b\u74b0\u5883\u306e\u5185\u3001\u7269\u7406\u5316\u5b66\u7684\u74b0\u5883\uff08\u4f8b\uff1a \u6e29\u5ea6\u3001pH\u3001\u6d78\u900f\u5727\u3001\u9178\u7d20\u5206\u5727\u304a\u3088\u3073\u4e8c\u9178\u5316\u70ad\u7d20\u5206\u5727\uff09\u304a\u3088\u3073\u751f\u7406\u5b66\u7684\u74b0\u5883\uff08\u4f8b\uff1a \u30db\u30eb\u30e2\u30f3\u304a\u3088\u3073\u6804\u990a\u7d20\u306e\u6fc3\u5ea6\uff09\u3092\u8abf\u7bc0\u3067\u304d\u308b\u3053\u3068<\/strong>\u3067\u3059\u3002\u6e29\u5ea6\u3092\u9664\u3044\u3066\u3001\u57f9\u990a\u74b0\u5883\u306f\u57f9\u5730\u306b\u3088\u3063\u3066\u5236\u5fa1\u3055\u308c\u307e\u3059\u3002<\/p>\n<p>\u57f9\u990a\u306e\u751f\u7406\u5b66\u7684\u74b0\u5883\u306f\u3001\u307e\u3060\u7269\u7406\u5316\u5b66\u7684\u74b0\u5883\u307b\u3069\u8a73\u7d30\u306b\u660e\u3089\u304b\u306b\u3055\u308c\u3066\u3044\u307e\u305b\u3093\u304c\u3001\u8840\u6e05\u6210\u5206\u306e\u3088\u308a\u6df1\u3044\u7406\u89e3\u3001\u7d30\u80de\u5897\u6b96\u306b\u5fc5\u8981\u306a\u6210\u9577\u56e0\u5b50\u306e\u540c\u5b9a\u3001\u304a\u3088\u3073\u57f9\u990a\u7269\u4e2d\u306e\u7d30\u80de\u306e\u30df\u30af\u30ed\u306a\u74b0\u5883\uff08\u4f8b\uff1a \u7d30\u80de\u9593\u76f8\u4e92\u4f5c\u7528\u3001\u6c17\u4f53\u306e\u62e1\u6563\u304a\u3088\u3073\u57fa\u8cea\u3068\u306e\u76f8\u4e92\u4f5c\u7528\uff09\u306e\u3088\u308a\u6df1\u3044\u7406\u89e3\u306b\u3088\u3063\u3066\u3001\u73fe\u5728\u3001<strong>\u7279\u5b9a\u306e\u7d30\u80de\u7cfb\u3067\u306f\u7121\u8840\u6e05\u57f9\u5730\u3067\u306e\u57f9\u990a\u304c\u53ef\u80fd<\/strong>\u3068\u306a\u3063\u3066\u3044\u307e\u3059\u3002<\/p>\n<p>\u4eca\u56de\u306f<strong>\u57f9\u5730\u306e\u7d44\u6210\u3084pH\u3001\u6e29\u5ea6\u306a\u3069\u7d30\u80de\u57f9\u990a\u306b\u304a\u3051\u308b\u57f9\u990a\u74b0\u5883<\/strong>\u306b\u3064\u3044\u3066\u3054\u7d39\u4ecb\u3057\u307e\u3059\u3002<\/p>\n<h2>\u63a5\u7740\u57f9\u990a\u3068\u6d6e\u904a\u57f9\u990a\u306e\u7279\u5fb4<\/h2>\n<p>\u7d30\u80de\u57f9\u990a\u306e\u57fa\u672c\u7684\u306a\u30b7\u30b9\u30c6\u30e0\u306b\u306f\u3001<strong>\u7d30\u80de\u3092\u4eba\u5de5\u57fa\u8cea\u4e0a\u3067\u5358\u5c64\u306b\u6210\u9577\u3055\u305b\u308b\u30b7\u30b9\u30c6\u30e0\uff08\u3059\u306a\u308f\u3061\u3001\u63a5\u7740\u57f9\u990a\uff09<\/strong>\u3068\u3001<strong>\u7d30\u80de\u3092\u57f9\u5730\u4e2d\u3067\u81ea\u7531\u306b\u6d6e\u904a\u3055\u305b\u3066\u6210\u9577\u3055\u305b\u308b\u30b7\u30b9\u30c6\u30e0\uff08\u3059\u306a\u308f\u3061\u3001\u6d6e\u904a\u57f9\u990a\uff09<\/strong>\u306e2\u7a2e\u985e\u304c\u5b58\u5728\u3057\u307e\u3059\u3002<\/p>\n<p><strong>\u810a\u690e\u52d5\u7269\u306b\u7531\u6765\u3059\u308b\u7d30\u80de\u306f\u3001\u9020\u8840\u7d30\u80de\u7cfb\u304a\u3088\u3073\u305d\u306e\u4ed6\u5c11\u6570\u306e\u7d30\u80de\u7cfb\u3092\u9664\u304d\u3001\u305d\u306e\u5927\u90e8\u5206\u304c\u63a5\u7740\u4f9d\u5b58\u6027<\/strong>\u3067\u3042\u308a\u3001\u7d30\u80de\u306e\u63a5\u7740\u3068\u62e1\u6563\u304c\u53ef\u80fd\u3068\u306a\u308b\u3088\u3046\u306a\u7279\u5225\u306a\u51e6\u7406\uff08\u3059\u306a\u308f\u3061\u3001\u7d44\u7e54\u57f9\u990a\u51e6\u7406\uff09\u304c\u65bd\u3055\u308c\u305f\u3001\u9069\u5207\u306a\u57fa\u8cea\u4e0a\u3067\u57f9\u990a\u3055\u308c\u308b\u5fc5\u8981\u304c\u3042\u308a\u307e\u3059\u3002\u3057\u304b\u3057\u3001<strong>\u591a\u304f\u306e\u7d30\u80de\u7cfb\u306f\u3001\u6d6e\u904a\u57f9\u990a\u306b\u3082\u9069\u5fdc\u3059\u308b\u3053\u3068\u304c\u53ef\u80fd<\/strong>\u3067\u3059\u3002\u540c\u69d8\u306b\u3001\u5e02\u8ca9\u306e\u6606\u866b\u7d30\u80de\u7cfb\u306e\u5927\u90e8\u5206\u306f\u3001\u5358\u5c64\u57f9\u990a\u306b\u304a\u3044\u3066\u3082\u6d6e\u904a\u57f9\u990a\u306b\u304a\u3044\u3066\u3082\u5341\u5206\u306b\u6210\u9577\u3057\u307e\u3059\u3002<\/p>\n<p>\u6d6e\u904a\u57f9\u990a\u3055\u308c\u3066\u3044\u308b\u7d30\u80de\u306f\u3001\u7d44\u7e54\u57f9\u990a\u51e6\u7406\u3055\u308c\u3066\u3044\u306a\u3044<a href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/life-science\/cell-culture\/cell-culture-plastics\/cell-culture-flasks.html?CID=bid_clb_cce_r04_jp_cp0000_pjt0000_bid00000_0so_blg_op_awa_oc_s00_cc5_Social_LAB\" target=\"_blank\" rel=\"noopener noreferrer\">\u57f9\u990a\u30d5\u30e9\u30b9\u30b3<\/a>\u4e2d\u3067\u7dad\u6301\u3059\u308b\u3053\u3068\u304c\u53ef\u80fd\u3067\u3059\u3002\u3057\u304b\u3057\u3001\u8868\u9762\u7a4d\u3042\u305f\u308a\u306e\u7d30\u80de\u5bb9\u91cf\u304c\u3001\u5341\u5206\u306a\u6c17\u4f53\u4ea4\u63db\u304c\u59a8\u3052\u3089\u308c\u308b\u7a0b\u5ea6\uff08\u901a\u5e38\u30010.2 \uff5e0.5 mL\/cm<sup>2<\/sup>\uff09\u3092\u8d85\u3048\u3066\u5897\u52a0\u3059\u308b\u3068\u3001\u57f9\u5730\u3092\u652a\u62cc\u3059\u308b\u3053\u3068\u304c\u5fc5\u8981\u3067\u3059\u3002\u652a\u62cc\u306b\u306f\u901a\u5e38\u3001<a href=\"https:\/\/www.thermofisher.com\/search\/browse\/featured\/jp\/ja\/80013310?CID=bid_clb_cce_r04_jp_cp0000_pjt0000_bid00000_0so_blg_op_awa_oc_s00_cc5_Social_LAB\" target=\"_blank\" rel=\"noopener noreferrer\">\u30de\u30b0\u30cd\u30c1\u30c3\u30af\u30b9\u30bf\u30fc\u30e9\u30fc<\/a>\u307e\u305f\u306f<a href=\"https:\/\/www.thermofisher.com\/order\/catalog\/product\/2605-0001?CID=bid_clb_cce_r04_jp_cp0000_pjt0000_bid00000_0so_blg_op_awa_oc_s00_cc5_Social_LAB\" target=\"_blank\" rel=\"noopener noreferrer\">\u30b9\u30d4\u30ca\u30fc\u30d5\u30e9\u30b9\u30b3<\/a>\u304c\u4f7f\u7528\u3055\u308c\u307e\u3059\u3002<\/p>\n<table>\n<caption>\u88681 \u63a5\u7740\u57f9\u990a\u3068\u6d6e\u904a\u57f9\u990a\u306e\u7279\u5fb4<\/caption>\n<tbody>\n<tr>\n<td style=\"text-align: center\"><strong>\u63a5\u7740\u57f9\u990a<\/strong><\/td>\n<td style=\"text-align: center\"><strong>\u6d6e\u904a\u7d30\u80de<\/strong><\/td>\n<\/tr>\n<tr>\n<td>\u521d\u4ee3\u57f9\u990a\u3092\u542b\u3080\u3001\u5927\u90e8\u5206\u306e\u7d30\u80de\u578b\u306b\u9069\u3057\u3066\u3044\u307e\u3059\u3002<\/td>\n<td>\u6d6e\u904a\u57f9\u990a\u306b\u9069\u5fdc\u5316\u3057\u305f\u7d30\u80de\u304a\u3088\u3073\u4ed6\u306e\u3044\u304f\u3064\u304b\u306e\u975e\u63a5\u7740\u6027\u306e\u7d30\u80de\u7cfb\uff08\u4f8b\uff1a \u9020\u8840\u7d30\u80de\uff09\u306b\u9069\u3057\u3066\u3044\u307e\u3059\u3002<\/td>\n<\/tr>\n<tr>\n<td>\u5b9a\u671f\u7684\u306a\u690d\u3048\u7d99\u304e\u304c\u5fc5\u8981\u3067\u3059\u304c\u3001\u5012\u7acb\u9855\u5fae\u93e1\u4e0b\u3067\u5bb9\u6613\u306b\u76ee\u8996\u89b3\u5bdf\u3059\u308b\u3053\u3068\u304c\u53ef\u80fd\u3067\u3059\u3002<\/td>\n<td>\u690d\u3048\u7d99\u304e\u306f\u5bb9\u6613\u3067\u3059\u304c\u3001\u6210\u9577\u30d1\u30bf\u30fc\u30f3\u306e\u8ffd\u8de1\u306b\u306f\u3001\u6bce\u65e5\u306e\u7d30\u80de\u30ab\u30a6\u30f3\u30c8\u3068\u6210\u9577\u7387\u6c7a\u5b9a\u304c\u5fc5\u8981\u3067\u3059\u3002\u6210\u9577\u3092\u4fc3\u9032\u3059\u308b\u305f\u3081\u306b\u3001\u57f9\u990a\u7269\u3092\u5e0c\u91c8\u3059\u308b\u3053\u3068\u304c\u53ef\u80fd\u3067\u3059\u3002<\/td>\n<\/tr>\n<tr>\n<td>\u7d30\u80de\u306f\u3001\u9175\u7d20\u7684\uff08\u4f8b\uff1a <a href=\"https:\/\/www.thermofisher.com\/us\/en\/home\/life-science\/cell-culture\/mammalian-cell-culture\/reagents\/trypsin\/tryple-express.html?CID=bid_clb_cce_r04_jp_cp0000_pjt0000_bid00000_0so_blg_op_awa_oc_s00_cc5_Social_LAB\" target=\"_blank\" rel=\"noopener noreferrer\">Gibco\u2122 TrypLE\u2122 Express<\/a>\u304a\u3088\u3073<a href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/life-science\/cell-culture\/mammalian-cell-culture\/reagents\/trypsin\/trypsin.html?CID=bid_clb_cce_r04_jp_cp0000_pjt0000_bid00000_0so_blg_op_awa_oc_s00_cc5_Social_LAB\" target=\"_blank\" rel=\"noopener noreferrer\">\u30c8\u30ea\u30d7\u30b7\u30f3<\/a>\uff09\u307e\u305f\u306f\u6a5f\u68b0\u7684\u306b\u89e3\u96e2\u3059\u308b\u5fc5\u8981\u304c\u3042\u308a\u307e\u3059\u3002<\/td>\n<td>\u9175\u7d20\u7684\u307e\u305f\u306f\u6a5f\u68b0\u7684\u89e3\u96e2\u306e\u5fc5\u8981\u306f\u3042\u308a\u307e\u305b\u3093\u3002<\/td>\n<\/tr>\n<tr>\n<td>\u6210\u9577\u306f\u3001\u8868\u9762\u7a4d\u306b\u3088\u308a\u898f\u5b9a\u3055\u308c\u3001\u305d\u306e\u305f\u3081\u53ce\u91cf\u304c\u9650\u5b9a\u3055\u308c\u308b\u5834\u5408\u304c\u3042\u308a\u307e\u3059\u3002<\/td>\n<td>\u6210\u9577\u306f\u3001\u57f9\u5730\u4e2d\u306e\u7d30\u80de\u6fc3\u5ea6\u306b\u3088\u3063\u3066\u898f\u5b9a\u3055\u308c\u3001\u5bb9\u6613\u306b\u30b9\u30b1\u30fc\u30eb\u30a2\u30c3\u30d7\u3059\u308b\u3053\u3068\u304c\u53ef\u80fd\u3067\u3059\u3002<\/td>\n<\/tr>\n<tr>\n<td>\u7d44\u7e54\u57f9\u990a\u51e6\u7406\u3057\u305f\u5bb9\u5668\u304c\u5fc5\u8981\u3067\u3059\u3002<\/td>\n<td>\u7d44\u7e54\u57f9\u990a\u51e6\u7406\u3057\u3066\u3044\u306a\u3044\u5bb9\u5668\u4e2d\u3067\u3082\u57f9\u990a\u304c\u53ef\u80fd\u3067\u3059\u304c\u3001\u5341\u5206\u306a\u6c17\u4f53\u4ea4\u63db\u306e\u305f\u3081\u306b\u652a\u62cc\uff08\u632f\u3068\u3046\u307e\u305f\u306f\u304b\u304d\u6df7\u305c\uff09\u304c\u5fc5\u8981\u3067\u3059\u3002<\/td>\n<\/tr>\n<tr>\n<td>\u7d30\u80de\u5b66\u3084\u7d99\u7d9a\u7684\u306a\u57f9\u990a\u7523\u7269\u306e\u56de\u53ce\u304a\u3088\u3073\u305d\u306e\u4ed6\u591a\u304f\u306e\u7814\u7a76\u306b\u5229\u7528\u3055\u308c\u3066\u3044\u307e\u3059\u3002<\/td>\n<td>\u30bf\u30f3\u30d1\u30af\u8cea\u306e\u30d0\u30eb\u30af\u751f\u7523\u3001\u30d0\u30c3\u30c1\u56de\u53ce\u304a\u3088\u3073\u305d\u306e\u4ed6\u591a\u304f\u306e\u7814\u7a76\u306b\u5229\u7528\u3055\u308c\u3066\u3044\u307e\u3059\u3002<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2>\u57f9\u5730<\/h2>\n<p>\u57f9\u5730\u306f\u3001\u7d30\u80de\u306e\u6210\u9577\u306b\u5fc5\u8981\u306a\u6804\u990a\u7d20\u3001\u6210\u9577\u56e0\u5b50\u304a\u3088\u3073\u30db\u30eb\u30e2\u30f3\u3092\u4f9b\u7d66\u3057\u3001\u307e\u305f\u57f9\u990a\u6db2\u306epH\u304a\u3088\u3073\u6d78\u900f\u5727\u3092\u5236\u5fa1\u3059\u308b\u305f\u3081\u3001<strong>\u57f9\u990a\u74b0\u5883\u306e\u4e2d\u3067\u6700\u3082\u91cd\u8981\u306a\u8981\u7d20<\/strong>\u3067\u3042\u308b\u3068\u8a00\u3048\u307e\u3059\u3002<\/p>\n<p>\u521d\u671f\u306e\u7d30\u80de\u57f9\u990a\u5b9f\u9a13\u306f\u3001\u7d44\u7e54\u62bd\u51fa\u7269\u3084\u4f53\u6db2\u304b\u3089\u5f97\u3089\u308c\u308b\u81ea\u7136\u306e\u57f9\u5730\u3092\u5229\u7528\u3057\u3066\u884c\u308f\u308c\u3066\u3044\u307e\u3057\u305f\u304c\u3001\u6a19\u6e96\u5316\u306e\u5fc5\u8981\u6027\u3001\u57f9\u5730\u306e\u54c1\u8cea\u306e\u554f\u984c\u3001\u304a\u3088\u3073\u9700\u8981\u306e\u5897\u52a0\u304b\u3089\u3001\u5408\u6210\u57f9\u5730\u304c\u958b\u767a\u3055\u308c\u307e\u3057\u305f\u3002\u57fa\u672c\u7684\u306a\u57f9\u5730\u306e\u5206\u985e\u306b\u306f\u3001<a href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/life-science\/cell-culture\/mammalian-cell-culture\/cell-culture-media.html?CID=bid_clb_cce_r04_jp_cp0000_pjt0000_bid00000_0so_blg_op_awa_oc_s00_cc5_Social_LAB\" target=\"_blank\" rel=\"noopener noreferrer\">\u57fa\u672c\u57f9\u5730<\/a>\u3001<a href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/life-science\/cell-culture\/mammalian-cell-culture\/cell-culture-media.html?CID=bid_clb_cce_r04_jp_cp0000_pjt0000_bid00000_0so_blg_op_awa_oc_s00_cc5_Social_LAB\" target=\"_blank\" rel=\"noopener noreferrer\">\u8840\u6e05\u4f4e\u6e1b\u57f9\u5730<\/a>\u304a\u3088\u3073<a href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/life-science\/cell-culture\/mammalian-cell-culture\/cell-culture-media\/serum-free-media.html?CID=bid_clb_cce_r04_jp_cp0000_pjt0000_bid00000_0so_blg_op_awa_oc_s00_cc5_Social_LAB\" target=\"_blank\" rel=\"noopener noreferrer\">\u7121\u8840\u6e05\u57f9\u5730<\/a>\u306e\u4e09\u7a2e\u985e\u304c\u3042\u308a\u3001\u305d\u308c\u305e\u308c\u6dfb\u52a0\u3059\u308b\u8840\u6e05\u306e\u5fc5\u8981\u91cf\u304c\u7570\u306a\u308a\u307e\u3059\u3002<\/p>\n<p><a href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/life-science\/cell-culture\/mammalian-cell-culture\/fbs.html?CID=bid_clb_cce_r04_jp_cp0000_pjt0000_bid00000_0so_blg_op_awa_oc_s00_cc5_Social_LAB\" target=\"_blank\" rel=\"noopener noreferrer\">\u8840\u6e05<\/a>\u306f\u3001<strong>\u57fa\u672c\u57f9\u5730\u4e2d\u3067\u306e\u7d30\u80de\u306e\u57f9\u990a\u306b\u304a\u3044\u3066\u3001\u6210\u9577\u56e0\u5b50\u3001\u63a5\u7740\u56e0\u5b50\u3001\u30db\u30eb\u30e2\u30f3\u3001\u8102\u8cea\u304a\u3088\u3073\u30df\u30cd\u30e9\u30eb\u306e\u4f9b\u7d66\u6e90\u3068\u3057\u3066\u5fc5\u8981\u4e0d\u53ef\u6b20\u306a\u91cd\u8981\u56e0\u5b50<\/strong>\u3067\u3059\u3002\u3055\u3089\u306b\u3001\u8840\u6e05\u306f\u7d30\u80de\u819c\u306e\u900f\u904e\u6027\u3092\u5236\u5fa1\u3057\u3001\u8102\u8cea\u3001\u9175\u7d20\u3001\u5fae\u91cf\u6804\u990a\u7d20\u304a\u3088\u3073\u5fae\u91cf\u5143\u7d20\u3092\u7d30\u80de\u3078\u53d6\u308a\u8fbc\u3080\u30ad\u30e3\u30ea\u30a2\u3068\u3057\u3066\u306e\u50cd\u304d\u3092\u6301\u3061\u307e\u3059\u3002\u3057\u304b\u3057\u3001\u57f9\u5730\u4e2d\u3067\u306e\u8840\u6e05\u306e\u4f7f\u7528\u306b\u306f\u3001\u9ad8\u3044\u30b3\u30b9\u30c8\u3001\u6a19\u6e96\u5316\u306e\u554f\u984c\u3001\u7279\u7570\u6027\u3001\u591a\u69d8\u6027\u3001\u304a\u3088\u3073\u7279\u5b9a\u306e\u57f9\u990a\u7d30\u80de\u306b\u304a\u3051\u308b\u6210\u9577\u3084\u7d30\u80de\u6a5f\u80fd\u306e\u523a\u6fc0\u307e\u305f\u306f\u6291\u5236\u306e\u3088\u3046\u306a\u671b\u307e\u3057\u304f\u306a\u3044\u52b9\u679c\u3092\u542b\u3081\u3001\u591a\u304f\u306e\u6b20\u70b9\u3082\u5b58\u5728\u3057\u307e\u3059\u3002\u307e\u305f\u3001\u8840\u6e05\u3092\u4fe1\u983c\u306e\u304a\u3051\u308b\u4f9b\u7d66\u8005\u304b\u3089\u5165\u624b\u3057\u306a\u304b\u3063\u305f\u5834\u5408\u306b\u306f\u3001\u8840\u6e05\u306e\u6c5a\u67d3\u306e\u305f\u3081\u306b\u3001\u7d30\u80de\u57f9\u990a\u5b9f\u9a13\u306e\u6210\u529f\u304c\u5927\u304d\u304f\u8105\u304b\u3055\u308c\u308b\u53ef\u80fd\u6027\u304c\u3042\u308a\u307e\u3059\u3002\u3053\u306e\u3088\u3046\u306a\u5371\u967a\u3092\u56de\u907f\u3067\u304d\u308b\u3088\u3046\u3001\u8840\u6e05\u3092\u542b\u3081\u305f\u3059\u3079\u3066\u306e\u30b5\u30fc\u30e2\u30d5\u30a3\u30c3\u30b7\u30e3\u30fc\u30b5\u30a4\u30a8\u30f3\u30c6\u30a3\u30d5\u30a3\u30c3\u30af\u304a\u3088\u3073Gibco\u2122\u88fd\u54c1\u306b\u95a2\u3057\u3066\u306f\u3001\u6c5a\u67d3\u7269\u8cea\u306e\u691c\u67fb\u304c\u884c\u308f\u308c\u3066\u304a\u308a\u3001\u305d\u306e\u54c1\u8cea\u3001\u5b89\u5168\u6027\u3001\u4e00\u8cab\u6027\u304a\u3088\u3073\u898f\u5236\u9075\u5b88\u306f\u4fdd\u8a3c\u3055\u308c\u3066\u3044\u307e\u3059\u3002<\/p>\n<h3>\u57fa\u672c\u57f9\u5730<\/h3>\n<p>\u5927\u90e8\u5206\u306e\u7d30\u80de\u7cfb\u306f\u3001<a href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/life-science\/cell-culture\/mammalian-cell-culture\/cell-culture-media.html?CID=bid_clb_cce_r04_jp_cp0000_pjt0000_bid00000_0so_blg_op_awa_oc_s00_cc5_Social_LAB\" target=\"_blank\" rel=\"noopener noreferrer\">\u57fa\u672c\u57f9\u5730<\/a>\u4e2d\u3067\u826f\u597d\u306b\u6210\u9577\u3057\u307e\u3059\u3002<strong>\u57fa\u672c\u57f9\u5730\u306b\u306f\u3001\u30a2\u30df\u30ce\u9178\u3001\u30d3\u30bf\u30df\u30f3\u3001\u7121\u6a5f\u5869\u304a\u3088\u3073\u30b0\u30eb\u30b3\u30fc\u30b9\u306a\u3069\u306e\u70ad\u7d20\u6e90\u304c\u542b\u307e\u308c\u3066\u3044\u307e\u3059<\/strong>\u304c\u3001\u3053\u308c\u3089\u306e\u57fa\u672c\u57f9\u5730\u6210\u5206\u306b\u306f\u3001\u8840\u6e05\u3092\u3055\u3089\u306b\u6dfb\u52a0\u3059\u308b\u3053\u3068\u304c\u5fc5\u8981\u3067\u3059\u3002<\/p>\n<h3>\u8840\u6e05\u4f4e\u6e1b\u57f9\u5730<\/h3>\n<p>\u7d30\u80de\u57f9\u990a\u5b9f\u9a13\u306b\u304a\u3044\u3066\u3001\u8840\u6e05\u306e\u671b\u307e\u3057\u304f\u306a\u3044\u52b9\u679c\u3092\u4f4e\u6e1b\u3055\u305b\u308b\u3082\u3046\u4e00\u3064\u306e\u65b9\u6cd5\u3068\u3057\u3066\u3001<a href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/life-science\/cell-culture\/mammalian-cell-culture\/cell-culture-media.html?CID=bid_clb_cce_r04_jp_cp0000_pjt0000_bid00000_0so_blg_op_awa_oc_s00_cc5_Social_LAB\" target=\"_blank\" rel=\"noopener noreferrer\">\u8840\u6e05\u4f4e\u6e1b\u57f9\u5730<\/a>\u306e\u4f7f\u7528\u304c\u3042\u308a\u307e\u3059\u3002<strong>\u8840\u6e05\u4f4e\u6e1b\u57f9\u5730\u306f\u3001\u6804\u990a\u7d20\u304a\u3088\u3073\u52d5\u7269\u7531\u6765\u306e\u56e0\u5b50\u3092\u6dfb\u52a0\u3057\u305f\u57fa\u672c\u57f9\u5730\u3067\u3001\u5fc5\u8981\u306a\u8840\u6e05\u306e\u91cf\u3092\u4f4e\u6e1b\u3067\u304d\u307e\u3059\u3002<\/strong><\/p>\n<h3>\u7121\u8840\u6e05\u57f9\u5730<\/h3>\n<p><a href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/life-science\/cell-culture\/mammalian-cell-culture\/cell-culture-media\/serum-free-media.html?CID=bid_clb_cce_r04_jp_cp0000_pjt0000_bid00000_0so_blg_op_awa_oc_s00_cc5_Social_LAB\" target=\"_blank\" rel=\"noopener noreferrer\">\u7121\u8840\u6e05\u57f9\u5730<\/a>\uff08SFM\uff09\u3067\u306f\u3001<strong>\u8840\u6e05\u3092\u9069\u5207\u306a\u6804\u990a\u6210\u5206\u304a\u3088\u3073\u30db\u30eb\u30e2\u30f3\u6210\u5206\u3067\u7f6e\u304d\u63db\u3048\u308b\u3053\u3068\u306b\u3088\u308a\u3001\u52d5\u7269\u8840\u6e05\u4f7f\u7528\u306e\u554f\u984c\u3092\u56de\u907f\u3067\u304d\u307e\u3059<\/strong>\u3002\u30c1\u30e3\u30a4\u30cb\u30fc\u30ba\u30cf\u30e0\u30b9\u30bf\u30fc\u5375\u5de3\u7d30\u80de\uff08CHO\uff09\u306e\u907a\u4f1d\u5b50\u7d44\u63db\u3048\u30bf\u30f3\u30d1\u30af\u8cea\u7523\u751f\u7d30\u80de\u7cfb\u3001\u7a2e\u3005\u306e\u878d\u5408\u7d30\u80de\u7cfb\u3001\u6606\u866b\u7d30\u80de\u7cfb\u306eSf9\u304a\u3088\u3073Sf21\uff08Spodoptera frugiperda\uff09\u304a\u3088\u3073\u30a6\u30a4\u30eb\u30b9\u751f\u7523\u306e\u5bbf\u4e3b\u3068\u306a\u308b\u7d30\u80de\u7cfb\uff08\u4f8b\uff1a 293\u3001VERO\u3001MDCK\u304a\u3088\u3073MDBK\uff09\u3001\u304a\u3088\u3073\u305d\u306e\u4ed6\u306e\u7d30\u80de\u3092\u542b\u3080<strong>\u591a\u304f\u306e\u521d\u4ee3\u57f9\u990a\u304a\u3088\u3073\u7d30\u80de\u7cfb\u306b\u5bfe\u3059\u308b\u7121\u8840\u6e05\u57f9\u5730\u304c\u5b58\u5728\u3057\u307e\u3059<\/strong>\u3002\u7121\u8840\u6e05\u57f9\u5730\u3092\u4f7f\u7528\u3059\u308b\u6700\u3082\u5927\u304d\u306a\u5229\u70b9\u306e\u4e00\u3064\u306f\u3001<strong>\u9069\u5207\u306a\u6210\u9577\u56e0\u5b50\u306e\u7d44\u307f\u5408\u308f\u305b\u3092\u9078\u629e\u3059\u308b\u3053\u3068\u306b\u3088\u3063\u3066\u3001\u7279\u5b9a\u306e\u7d30\u80de\u578b\u306b\u9078\u629e\u7684\u306a\u57f9\u5730\u306e\u8abf\u88fd\u304c\u53ef\u80fd\u3068\u306a\u308b<\/strong>\u3053\u3068\u3067\u3059\u3002\u7121\u8840\u6e05\u57f9\u5730\u306e\u5229\u70b9\u304a\u3088\u3073\u6b20\u70b9\u3092\u4e0b\u8a18\u306e\u8868\u306b\u307e\u3068\u3081\u3066\u3042\u308a\u307e\u3059\u3002<\/p>\n<table>\n<caption>\u88682 \u7121\u8840\u6e05\u57f9\u5730\u306e\u5229\u70b9\u3068\u6b20\u70b9<\/caption>\n<tbody>\n<tr>\n<td style=\"text-align: center\"><strong>\u5229\u70b9<\/strong><\/td>\n<td style=\"text-align: center\"><strong>\u6b20\u70b9<\/strong><\/td>\n<\/tr>\n<tr>\n<td>\n<ul>\n<li>\u6210\u5206\u306e\u660e\u78ba\u3055<\/li>\n<li>\u512a\u308c\u305f\u4e00\u8cab\u6027<\/li>\n<li>\u5bb9\u6613\u306a\u7cbe\u88fd\u304a\u3088\u3073\u4e0b\u6d41\u64cd\u4f5c<\/li>\n<li>\u7d30\u80de\u6a5f\u80fd\u306e\u6b63\u78ba\u306a\u8a55\u4fa1<\/li>\n<li>\u751f\u7523\u6027\u306e\u5411\u4e0a<\/li>\n<li>\u751f\u7406\u5b66\u7684\u5fdc\u7b54\u306e\u3088\u308a\u512a\u308c\u305f\u5236\u5fa1<\/li>\n<li>\u7d30\u80de\u30e1\u30c7\u30a3\u30a8\u30fc\u30bf\u30fc\u306e\u3088\u308a\u512a\u308c\u305f\u691c\u51fa<\/li>\n<\/ul>\n<\/td>\n<td>\n<ul>\n<li>\u7d30\u80de\u578b\u7279\u7570\u7684\u306a\u57f9\u5730\u6210\u5206\u306e\u5fc5\u8981\u6027<\/li>\n<li>\u7d14\u5ea6\u306e\u9ad8\u3044\u8a66\u85ac\u306e\u5fc5\u8981\u6027<\/li>\n<li>\u6210\u9577\u901f\u5ea6\u306e\u4f4e\u4e0b<\/li>\n<\/ul>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2>pH<\/h2>\n<p><strong>\u6b63\u5e38\u306a\u54fa\u4e73\u985e\u7d30\u80de\u7cfb\u306e\u5927\u90e8\u5206\u306f\u3001pH7.4\u3067\u826f\u597d\u306b\u751f\u80b2\u3057\u3001\u7d30\u80de\u682a\u9593\u306e\u591a\u69d8\u6027\u306f\u6b86\u3069\u5b58\u5728\u3057\u307e\u305b\u3093<\/strong>\u3002\u3057\u304b\u3057\u3001\u3044\u304f\u3064\u304b\u306e\u5f62\u8cea\u8ee2\u63db\u7d30\u80de\u7cfb\u306f\u3001\u308f\u305a\u304b\u306b\u9178\u6027\u5bc4\u308a\u306e\u74b0\u5883\uff08pH 7.0\uff5e7.4\uff09\u3067\u3088\u308a\u3088\u304f\u751f\u80b2\u3059\u308b\u3053\u3068\u304c\u793a\u3055\u308c\u3066\u3044\u307e\u3059\u3002\u307e\u305f\u3001\u6b63\u5e38\u306a\u7dda\u7dad\u82bd\u7d30\u80de\u306e\u3044\u304f\u3064\u304b\u306f\u3001\u308f\u305a\u304b\u306b\u5869\u57fa\u6027\u5074\u306e\u74b0\u5883\uff08pH 7.4\uff5e7.7\uff09\u3092\u597d\u307f\u307e\u3059\u3002Sf9\u3084Sf21\u306a\u3069\u306e\u6606\u866b\u7d30\u80de\u7cfb\u3067\u306f\u3001pH 6.2\u304c\u6700\u9069\u306a\u6210\u80b2\u74b0\u5883\u3067\u3059\u3002<\/p>\n<h2>CO<sub>2<\/sub><\/h2>\n<p>\u5897\u6b96\u57f9\u5730\u306f\u3001<strong>\u57f9\u990a\u7269\u306epH\u3092\u5236\u5fa1\u3057\u3001pH\u306e\u5909\u5316\u306e\u57f9\u990a\u7d30\u80de\u306b\u5bfe\u3059\u308b\u5f71\u97ff\u3092\u548c\u3089\u3052\u307e\u3059<\/strong>\u3002\u4e00\u822c\u306b\u3001\u3053\u306e\u7de9\u885d\u4f5c\u7528\u306f\u6709\u6a5f\u5316\u5408\u7269\uff08\u4f8b\uff1a HEPES\uff09\u307e\u305f\u306f\u4e8c\u9178\u5316\u70ad\u7d20\u30fb\u91cd\u70ad\u9178\u5869\u30d9\u30fc\u30b9\u306e\u7de9\u885d\u6db2\u3092\u542b\u3080\u3053\u3068\u306b\u3088\u3063\u3066\u9054\u6210\u3055\u308c\u307e\u3059\u3002\u57f9\u5730\u306epH\u306f\u3001\u6eb6\u89e3\u3057\u3066\u3044\u308b\u4e8c\u9178\u5316\u70ad\u7d20\uff08CO<sub>2<\/sub>\uff09\u304a\u3088\u3073\u91cd\u70ad\u9178\u5869\uff08HCO<sub>3<\/sub><sup>&#8211;<\/sup>\uff09\u306e\u5fae\u5999\u306a\u30d0\u30e9\u30f3\u30b9\u306b\u4f9d\u5b58\u3057\u3066\u3044\u308b\u305f\u3081\u3001\u57f9\u5730\u306epH\u306f\u5927\u6c17\u4e2d\u306eCO<sub>2<\/sub>\u306b\u3088\u3063\u3066\u5909\u5316\u3057\u307e\u3059\u3002\u3053\u306e\u305f\u3081\u3001<strong>\u4e8c\u9178\u5316\u70ad\u7d20\u30fb\u91cd\u70ad\u9178\u5869\u30d9\u30fc\u30b9\u306e\u7de9\u885d\u6db2\u3067\u7de9\u885d\u3055\u308c\u3066\u3044\u308b\u57f9\u5730\u3092\u4f7f\u7528\u3059\u308b\u969b\u306b\u306f\u3001\u5916\u6765\u6027CO<sub>2<\/sub>\u3092\u4f7f\u7528\u3059\u308b\u3053\u3068\u304c\u5fc5\u8981<\/strong>\u3067\u3042\u308a\u3001\u7279\u306b\u3001\u958b\u653e\u578b\u306e\u57f9\u990a\u76bf\u3092\u7528\u3044\u3066\u7d30\u80de\u3092\u57f9\u990a\u3059\u308b\u5834\u5408\u3084\u3001\u5f62\u8cea\u8ee2\u63db\u3057\u305f\u7d30\u80de\u3092\u9ad8\u6fc3\u5ea6\u3067\u57f9\u990a\u3059\u308b\u5834\u5408\u306b\u306f\u5fc5\u8981\u3068\u3057\u307e\u3059\u3002\u7814\u7a76\u8005\u306e\u5927\u90e8\u5206\u306f\u3001\u5927\u6c17\u4e2d5\uff5e7%\u306eCO<sub>2<\/sub>\u3092\u4f7f\u7528\u3057\u3066\u304a\u308a\u3001\u7d30\u80de\u57f9\u990a\u5b9f\u9a13\u306e\u5927\u90e8\u5206\u3067\u306f4\uff5e10%\u306eCO<sub>2<\/sub>\u304c\u4e00\u822c\u7684\u306b\u4f7f\u7528\u3055\u308c\u3066\u3044\u307e\u3059\u3002\u3057\u304b\u3057\u3001\u5404\u57f9\u5730\u306b\u306f\u3001\u9069\u6b63\u306apH\u3068\u6d78\u900f\u5727\u3092\u9054\u6210\u3059\u308b\u305f\u3081\u306e\u3001\u63a8\u5968CO<sub>2<\/sub>\u5206\u5727\u304a\u3088\u3073\u91cd\u70ad\u9178\u5869\u6fc3\u5ea6\u304c\u5b58\u5728\u3057\u307e\u3059\u3002\u3055\u3089\u306b\u8a73\u3057\u3044\u60c5\u5831\u306b\u95a2\u3057\u3066\u306f\u3001\u57f9\u5730\u88fd\u9020\u30e1\u30fc\u30ab\u30fc\u306e\u8aac\u660e\u66f8\u3092\u53c2\u7167\u3057\u3066\u304f\u3060\u3055\u3044\u3002<\/p>\n<h2>\u6e29\u5ea6<\/h2>\n<p><strong>\u7d30\u80de\u57f9\u990a\u306e\u6700\u9069\u6e29\u5ea6\u306f\u3001\u7d30\u80de\u304c\u5206\u96e2\u3055\u308c\u305f\u5bbf\u4e3b\u306e\u4f53\u6e29\u306b\u5927\u304d\u304f\u4f9d\u5b58\u3057\u3001\u6e29\u5ea6\u306e\u89e3\u5256\u5b66\u7684\u5dee\u7570\u306b\u3082\u3042\u308b\u7a0b\u5ea6\u4f9d\u5b58\u3057\u307e\u3059<\/strong>\uff08\u4f8b\uff1a \u76ae\u819a\u306e\u6e29\u5ea6\u306f\u3001\u9aa8\u683c\u7b4b\u306e\u6e29\u5ea6\u3088\u308a\u4f4e\u3044\u5834\u5408\u304c\u3042\u308a\u307e\u3059\uff09\u3002\u7d30\u80de\u57f9\u990a\u306b\u304a\u3044\u3066\u306f\u3001\u904e\u5ea6\u306e\u4f4e\u6e29\u3088\u308a\u3082\u3001\u904e\u5ea6\u306e\u9ad8\u6e29\u306e\u65b9\u304c\u91cd\u7be4\u306a\u554f\u984c\u3067\u3059\u3002\u305d\u306e\u305f\u3081\u3001\u30a4\u30f3\u30ad\u30e5\u30d9\u30fc\u30bf\u30fc\u5185\u306e\u6e29\u5ea6\u306f\u3057\u3070\u3057\u3070\u3001\u6700\u9069\u6e29\u5ea6\u3088\u308a\u3082\u308f\u305a\u304b\u306b\u4f4e\u3044\u6e29\u5ea6\u306b\u8a2d\u5b9a\u3055\u308c\u3066\u3044\u307e\u3059\u3002<\/p>\n<ul>\n<li>\u30d2\u30c8\u304a\u3088\u3073\u54fa\u4e73\u985e\u306e\u7d30\u80de\u7cfb\u306e\u5927\u90e8\u5206\u306f\u3001\u751f\u80b2\u306e\u6700\u9069\u5316\u306e\u305f\u3081\u306b\u300136\u00b0C\u304b\u308937\u00b0C\u306e\u6e29\u5ea6\u3067\u7dad\u6301\u3055\u308c\u307e\u3059\u3002<\/li>\n<li>\u6606\u866b\u7d30\u80de\u306f\u3001\u751f\u80b2\u306e\u6700\u9069\u5316\u306e\u305f\u3081\u306b27\u00b0C\u3067\u57f9\u990a\u3055\u308c\u307e\u3059\u300227\u00b0C\u3088\u308a\u3082\u4f4e\u3044\u6e29\u5ea6\u3001\u304a\u3088\u307327\u00b0C\u304b\u308930\u00b0C\u306e\u6e29\u5ea6\u3067\u306f\u3001\u751f\u80b2\u304c\u9045\u304f\u306a\u308a\u307e\u3059\u300230\u00b0C\u3092\u8d85\u3048\u308b\u3068\u3001\u6606\u866b\u7d30\u80de\u306e\u751f\u5b58\u7387\u306f\u4f4e\u4e0b\u3057\u3001\u305d\u306e\u5f8c\u6e29\u5ea6\u309227\u00b0C\u306b\u623b\u3057\u3066\u3082\u3001\u7d30\u80de\u306f\u56de\u5fa9\u3057\u307e\u305b\u3093\u3002<\/li>\n<li>\u9ce5\u985e\u306e\u7d30\u80de\u7cfb\u306f\u3001\u6700\u5927\u6210\u9577\u306e\u305f\u3081\u306b\u300138.5\u00b0C\u3092\u5fc5\u8981\u3068\u3057\u307e\u3059\u300237\u00b0C\u3067\u3082\u7dad\u6301\u3059\u308b\u3053\u3068\u304c\u53ef\u80fd\u3067\u3059\u304c\u3001\u6210\u9577\u304c\u9045\u304f\u306a\u308a\u307e\u3059\u3002<\/li>\n<li>\u51b7\u8840\u52d5\u7269\uff08\u4f8b\uff1a \u4e21\u751f\u985e\u304a\u3088\u3073\u51b7\u6c34\u9b5a\uff09\u7531\u6765\u306e\u7d30\u80de\u7cfb\u306f\u300115\u00b0C\u304b\u308926\u00b0C\u306e\u5e83\u7bc4\u56f2\u306e\u6e29\u5ea6\u306b\u8010\u3048\u3089\u308c\u307e\u3059\u3002<\/li>\n<\/ul>\n<p>\u203b\u7d30\u80de\u57f9\u990a\u6761\u4ef6\u306f\u3001\u5404\u7d30\u80de\u578b\u306b\u3088\u3063\u3066\u7570\u306a\u308b\u3053\u3068\u306b\u6ce8\u610f\u3057\u3066\u304f\u3060\u3055\u3044\u3002\u7279\u5b9a\u306e\u7d30\u80de\u578b\u306b\u5fc5\u8981\u3068\u3055\u308c\u308b\u57f9\u990a\u6761\u4ef6\u304b\u3089\u306e\u9038\u8131\u306f\u3001\u7570\u5e38\u306a\u7d30\u80de\u578b\u306e\u767a\u73fe\u304b\u3089\u3001\u7d30\u80de\u57f9\u990a\u306e\u5b8c\u5168\u306a\u5931\u6557\u306b\u81f3\u308b\u69d8\u3005\u306a\u7d50\u679c\u3092\u5f15\u304d\u8d77\u3053\u3059\u53ef\u80fd\u6027\u304c\u3042\u308a\u307e\u3059\u3002\u305d\u306e\u305f\u3081\u5f53\u793e\u3067\u306f\u3001\u53d6\u308a\u6271\u3046\u7d30\u80de\u7cfb\u306b\u7cbe\u901a\u3057\u3001\u5b9f\u9a13\u306b\u4f7f\u7528\u3059\u308b\u5404\u88fd\u54c1\u4ed8\u5c5e\u306e\u8aac\u660e\u66f8\u306e\u8a18\u8f09\u5185\u5bb9\u306b\u53b3\u5bc6\u306b\u5f93\u308f\u308c\u308b\u3053\u3068\u3092\u63a8\u5968\u3057\u307e\u3059\u3002<\/p>\n<h2>\u3010\u7121\u6599\u30c0\u30a6\u30f3\u30ed\u30fc\u30c9\u3011Gibco\u7d30\u80de\u57f9\u990a\u57fa\u790e\u30cf\u30f3\u30c9\u30d6\u30c3\u30af<\/h2>\n<p>\u7d30\u80de\u57f9\u990a\u306b\u95a2\u3059\u308b\u57fa\u790e\u60c5\u5831\u3092\u89e3\u8aac\u3057\u305f\u30cf\u30f3\u30c9\u30d6\u30c3\u30af\u3092\u3054\u7528\u610f\u3057\u3066\u3044\u307e\u3059\uff08\u65e5\u672c\u8a9e\u7248\u3001\u7d04100\u30da\u30fc\u30b8\uff09\u3002PDF\u30d5\u30a1\u30a4\u30eb\u306e\u30c0\u30a6\u30f3\u30ed\u30fc\u30c9\u3092\u3054\u5e0c\u671b\u306e\u65b9\u306f\u3001\u4e0b\u8a18\u30dc\u30bf\u30f3\u3088\u308a\u304a\u7533\u3057\u8fbc\u307f\u304f\u3060\u3055\u3044\u3002<\/p>\n<p><a class=\"btn btn-red\" href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/global\/forms\/gibco-cell-culture-basics-handbook-form.html?CID=bid_clb_cce_r04_jp_cp0000_pjt0000_bid00000_0so_blg_op_awa_oc_s00_cc5_Social_LAB\" target=\"_blank\" rel=\"noopener\">\u30c0\u30a6\u30f3\u30ed\u30fc\u30c9<\/a><\/p>\n<p>&nbsp;<\/p>\n<p>\u7814\u7a76\u7528\u306b\u306e\u307f\u4f7f\u7528\u3067\u304d\u307e\u3059\u3002\u8a3a\u65ad\u7528\u306b\u306f\u4f7f\u7528\u3044\u305f\u3060\u3051\u307e\u305b\u3093\u3002<\/p>\n","protected":false},"excerpt":{"rendered":"<p>\u7d30\u80de\u57f9\u990a\u306e\u5927\u304d\u306a\u5229\u70b9\u306e\u4e00\u3064\u306f\u3001\u7d30\u80de\u304c\u5897\u6b96\u3059\u308b\u74b0\u5883\u306e\u5185\u3001\u7269\u7406\u5316\u5b66\u7684\u74b0\u5883\uff08\u4f8b\uff1a \u6e29\u5ea6\u3001pH\u3001\u6d78\u900f\u5727\u3001\u9178\u7d20\u5206\u5727\u304a\u3088\u3073\u4e8c\u9178\u5316\u70ad\u7d20\u5206\u5727\uff09\u304a\u3088\u3073\u751f\u7406\u5b66\u7684\u74b0\u5883\uff08\u4f8b\uff1a \u30db\u30eb\u30e2\u30f3\u304a\u3088\u3073\u6804\u990a\u7d20\u306e\u6fc3\u5ea6\uff09\u3092\u8abf\u7bc0\u3067\u304d\u308b\u3053\u3068\u3067\u3059\u3002\u4eca\u56de\u306f\u57f9\u5730\u306e\u7d44\u6210\u3084pH\u3001\u6e29\u5ea6\u306a\u3069\u7d30\u80de\u57f9\u990a\u306b\u304a\u3051\u308b\u57f9\u990a\u74b0\u5883\u306b\u3064\u3044\u3066\u3054\u7d39\u4ecb\u3057\u307e\u3059\u3002<\/p>\n","protected":false},"author":988,"featured_media":2784,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_monsterinsights_skip_tracking":false,"_genesis_hide_title":false,"_genesis_hide_breadcrumbs":false,"_genesis_hide_singular_image":false,"_genesis_hide_footer_widgets":false,"_genesis_custom_body_class":"","_genesis_custom_post_class":"","_genesis_layout":"","_jetpack_newsletter_access":"","_jetpack_dont_email_post_to_subs":false,"_jetpack_newsletter_tier_id":0,"_jetpack_memberships_contains_paywalled_content":false,"_jetpack_feature_clip_id":0,"_jetpack_memberships_contains_paid_content":false,"footnotes":"","jetpack_post_was_ever_published":false},"categories":[159],"tags":[23],"division":[],"class_list":{"0":"post-495","1":"post","2":"type-post","3":"status-publish","4":"format-standard","5":"has-post-thumbnail","7":"category-cell","8":"tag-cell-culture","9":"entry"},"_selected_authors":"","_selected_reviewers":"","acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v27.8 (Yoast SEO v27.8) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>\uff11\u304b\u3089\u5206\u304b\u308b\u7d30\u80de\u57f9\u990a\u306b\u304a\u3051\u308b\u57f9\u990a\u74b0\u5883 - Learning at the Bench<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/cell-culture-environment\/\" \/>\n<meta property=\"og:locale\" content=\"ja_JP\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"\uff11\u304b\u3089\u5206\u304b\u308b\u7d30\u80de\u57f9\u990a\u306b\u304a\u3051\u308b\u57f9\u990a\u74b0\u5883\" \/>\n<meta property=\"og:description\" content=\"\u7d30\u80de\u57f9\u990a\u306e\u5927\u304d\u306a\u5229\u70b9\u306e\u4e00\u3064\u306f\u3001\u7d30\u80de\u304c\u5897\u6b96\u3059\u308b\u74b0\u5883\u306e\u5185\u3001\u7269\u7406\u5316\u5b66\u7684\u74b0\u5883\uff08\u4f8b\uff1a \u6e29\u5ea6\u3001pH\u3001\u6d78\u900f\u5727\u3001\u9178\u7d20\u5206\u5727\u304a\u3088\u3073\u4e8c\u9178\u5316\u70ad\u7d20\u5206\u5727\uff09\u304a\u3088\u3073\u751f\u7406\u5b66\u7684\u74b0\u5883\uff08\u4f8b\uff1a \u30db\u30eb\u30e2\u30f3\u304a\u3088\u3073\u6804\u990a\u7d20\u306e\u6fc3\u5ea6\uff09\u3092\u8abf\u7bc0\u3067\u304d\u308b\u3053\u3068\u3067\u3059\u3002\u4eca\u56de\u306f\u57f9\u5730\u306e\u7d44\u6210\u3084pH\u3001\u6e29\u5ea6\u306a\u3069\u7d30\u80de\u57f9\u990a\u306b\u304a\u3051\u308b\u57f9\u990a\u74b0\u5883\u306b\u3064\u3044\u3066\u3054\u7d39\u4ecb\u3057\u307e\u3059\u3002\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/cell-culture-environment\/\" \/>\n<meta property=\"og:site_name\" content=\"Learning at the Bench\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/ThermoFisherJapan\" \/>\n<meta property=\"article:published_time\" content=\"2016-10-18T00:00:00+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2025-02-26T06:56:41+00:00\" \/>\n<meta property=\"og:image\" content=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/cell-culture-environment-title.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"1200\" \/>\n\t<meta property=\"og:image:height\" content=\"630\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"LATB Staff\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:creator\" content=\"@ThermoFisherJP\" \/>\n<meta name=\"twitter:site\" content=\"@ThermoFisherJP\" \/>\n<meta name=\"twitter:label1\" content=\"\u57f7\u7b46\u8005\" \/>\n\t<meta name=\"twitter:data1\" content=\"LATB Staff\" \/>\n\t<meta name=\"twitter:label2\" content=\"\u63a8\u5b9a\u8aad\u307f\u53d6\u308a\u6642\u9593\" \/>\n\t<meta name=\"twitter:data2\" content=\"11\u5206\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/cell-culture-environment\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/cell-culture-environment\\\/\"},\"author\":{\"name\":\"LATB Staff\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#\\\/schema\\\/person\\\/00a095a01d54afcdf9457465feb04f7d\"},\"headline\":\"\uff11\u304b\u3089\u5206\u304b\u308b\u7d30\u80de\u57f9\u990a\u306b\u304a\u3051\u308b\u57f9\u990a\u74b0\u5883\",\"datePublished\":\"2016-10-18T00:00:00+00:00\",\"dateModified\":\"2025-02-26T06:56:41+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/cell-culture-environment\\\/\"},\"wordCount\":55,\"commentCount\":0,\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/cell-culture-environment\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2019\\\/07\\\/cell-culture-environment-title.jpg\",\"keywords\":[\"\u7d30\u80de\u57f9\u990a\"],\"articleSection\":[\"\u7d30\u80de\u57f9\u990a\u30fb\u30a4\u30e1\u30fc\u30b8\u30f3\u30b0\"],\"inLanguage\":\"ja\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/cell-culture-environment\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/cell-culture-environment\\\/\",\"url\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/cell-culture-environment\\\/\",\"name\":\"\uff11\u304b\u3089\u5206\u304b\u308b\u7d30\u80de\u57f9\u990a\u306b\u304a\u3051\u308b\u57f9\u990a\u74b0\u5883 - Learning at the Bench\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/cell-culture-environment\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/cell-culture-environment\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2019\\\/07\\\/cell-culture-environment-title.jpg\",\"datePublished\":\"2016-10-18T00:00:00+00:00\",\"dateModified\":\"2025-02-26T06:56:41+00:00\",\"author\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#\\\/schema\\\/person\\\/00a095a01d54afcdf9457465feb04f7d\"},\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/cell-culture-environment\\\/#breadcrumb\"},\"inLanguage\":\"ja\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/cell-culture-environment\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"ja\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/cell-culture-environment\\\/#primaryimage\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2019\\\/07\\\/cell-culture-environment-title.jpg\",\"contentUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2019\\\/07\\\/cell-culture-environment-title.jpg\",\"width\":1200,\"height\":630,\"caption\":\"cell-culture-environment-title\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/cell-culture-environment\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"\uff11\u304b\u3089\u5206\u304b\u308b\u7d30\u80de\u57f9\u990a\u306b\u304a\u3051\u308b\u57f9\u990a\u74b0\u5883\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#website\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/\",\"name\":\"Learning at the Bench\",\"description\":\"\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"ja\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#\\\/schema\\\/person\\\/00a095a01d54afcdf9457465feb04f7d\",\"name\":\"LATB Staff\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"ja\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/8803277856c8b753feb4217dff0f9953327452df1a615c3c88b2f9864efb2ddd?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/8803277856c8b753feb4217dff0f9953327452df1a615c3c88b2f9864efb2ddd?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/8803277856c8b753feb4217dff0f9953327452df1a615c3c88b2f9864efb2ddd?s=96&d=mm&r=g\",\"caption\":\"LATB Staff\"},\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/author\\\/latbstaff\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"\uff11\u304b\u3089\u5206\u304b\u308b\u7d30\u80de\u57f9\u990a\u306b\u304a\u3051\u308b\u57f9\u990a\u74b0\u5883 - Learning at the Bench","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/cell-culture-environment\/","og_locale":"ja_JP","og_type":"article","og_title":"\uff11\u304b\u3089\u5206\u304b\u308b\u7d30\u80de\u57f9\u990a\u306b\u304a\u3051\u308b\u57f9\u990a\u74b0\u5883","og_description":"\u7d30\u80de\u57f9\u990a\u306e\u5927\u304d\u306a\u5229\u70b9\u306e\u4e00\u3064\u306f\u3001\u7d30\u80de\u304c\u5897\u6b96\u3059\u308b\u74b0\u5883\u306e\u5185\u3001\u7269\u7406\u5316\u5b66\u7684\u74b0\u5883\uff08\u4f8b\uff1a \u6e29\u5ea6\u3001pH\u3001\u6d78\u900f\u5727\u3001\u9178\u7d20\u5206\u5727\u304a\u3088\u3073\u4e8c\u9178\u5316\u70ad\u7d20\u5206\u5727\uff09\u304a\u3088\u3073\u751f\u7406\u5b66\u7684\u74b0\u5883\uff08\u4f8b\uff1a \u30db\u30eb\u30e2\u30f3\u304a\u3088\u3073\u6804\u990a\u7d20\u306e\u6fc3\u5ea6\uff09\u3092\u8abf\u7bc0\u3067\u304d\u308b\u3053\u3068\u3067\u3059\u3002\u4eca\u56de\u306f\u57f9\u5730\u306e\u7d44\u6210\u3084pH\u3001\u6e29\u5ea6\u306a\u3069\u7d30\u80de\u57f9\u990a\u306b\u304a\u3051\u308b\u57f9\u990a\u74b0\u5883\u306b\u3064\u3044\u3066\u3054\u7d39\u4ecb\u3057\u307e\u3059\u3002","og_url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/cell-culture-environment\/","og_site_name":"Learning at the Bench","article_publisher":"https:\/\/www.facebook.com\/ThermoFisherJapan","article_published_time":"2016-10-18T00:00:00+00:00","article_modified_time":"2025-02-26T06:56:41+00:00","og_image":[{"width":1200,"height":630,"url":"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/cell-culture-environment-title.jpg","type":"image\/jpeg"}],"author":"LATB Staff","twitter_card":"summary_large_image","twitter_creator":"@ThermoFisherJP","twitter_site":"@ThermoFisherJP","twitter_misc":{"\u57f7\u7b46\u8005":"LATB Staff","\u63a8\u5b9a\u8aad\u307f\u53d6\u308a\u6642\u9593":"11\u5206"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/cell-culture-environment\/#article","isPartOf":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/cell-culture-environment\/"},"author":{"name":"LATB Staff","@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#\/schema\/person\/00a095a01d54afcdf9457465feb04f7d"},"headline":"\uff11\u304b\u3089\u5206\u304b\u308b\u7d30\u80de\u57f9\u990a\u306b\u304a\u3051\u308b\u57f9\u990a\u74b0\u5883","datePublished":"2016-10-18T00:00:00+00:00","dateModified":"2025-02-26T06:56:41+00:00","mainEntityOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/cell-culture-environment\/"},"wordCount":55,"commentCount":0,"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/cell-culture-environment\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/cell-culture-environment-title.jpg","keywords":["\u7d30\u80de\u57f9\u990a"],"articleSection":["\u7d30\u80de\u57f9\u990a\u30fb\u30a4\u30e1\u30fc\u30b8\u30f3\u30b0"],"inLanguage":"ja","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/cell-culture-environment\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/cell-culture-environment\/","url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/cell-culture-environment\/","name":"\uff11\u304b\u3089\u5206\u304b\u308b\u7d30\u80de\u57f9\u990a\u306b\u304a\u3051\u308b\u57f9\u990a\u74b0\u5883 - Learning at the Bench","isPartOf":{"@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/cell-culture-environment\/#primaryimage"},"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/cell-culture-environment\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/cell-culture-environment-title.jpg","datePublished":"2016-10-18T00:00:00+00:00","dateModified":"2025-02-26T06:56:41+00:00","author":{"@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#\/schema\/person\/00a095a01d54afcdf9457465feb04f7d"},"breadcrumb":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/cell-culture-environment\/#breadcrumb"},"inLanguage":"ja","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/cell-culture-environment\/"]}]},{"@type":"ImageObject","inLanguage":"ja","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/cell-culture-environment\/#primaryimage","url":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/cell-culture-environment-title.jpg","contentUrl":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/cell-culture-environment-title.jpg","width":1200,"height":630,"caption":"cell-culture-environment-title"},{"@type":"BreadcrumbList","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/cell-culture-environment\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/"},{"@type":"ListItem","position":2,"name":"\uff11\u304b\u3089\u5206\u304b\u308b\u7d30\u80de\u57f9\u990a\u306b\u304a\u3051\u308b\u57f9\u990a\u74b0\u5883"}]},{"@type":"WebSite","@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#website","url":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/","name":"Learning at the Bench","description":"","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"ja"},{"@type":"Person","@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#\/schema\/person\/00a095a01d54afcdf9457465feb04f7d","name":"LATB Staff","image":{"@type":"ImageObject","inLanguage":"ja","@id":"https:\/\/secure.gravatar.com\/avatar\/8803277856c8b753feb4217dff0f9953327452df1a615c3c88b2f9864efb2ddd?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/8803277856c8b753feb4217dff0f9953327452df1a615c3c88b2f9864efb2ddd?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/8803277856c8b753feb4217dff0f9953327452df1a615c3c88b2f9864efb2ddd?s=96&d=mm&r=g","caption":"LATB Staff"},"url":"https:\/\/admin.acceleratingscience.com\/author\/latbstaff\/"}]}},"taxonomy_info":{"category":[{"value":159,"label":"\u7d30\u80de\u57f9\u990a\u30fb\u30a4\u30e1\u30fc\u30b8\u30f3\u30b0"}],"post_tag":[{"value":23,"label":"\u7d30\u80de\u57f9\u990a"}]},"featured_image_src_large":["https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/cell-culture-environment-title-1024x538.jpg",760,399,true],"author_info":{"display_name":"LATB Staff","author_link":"https:\/\/admin.acceleratingscience.com\/author\/latbstaff\/"},"comment_info":0,"category_info":[{"term_id":159,"name":"\u7d30\u80de\u57f9\u990a\u30fb\u30a4\u30e1\u30fc\u30b8\u30f3\u30b0","slug":"cell","term_group":0,"term_taxonomy_id":159,"taxonomy":"category","description":"","parent":0,"count":103,"filter":"raw","meta":[],"cat_ID":159,"category_count":103,"category_description":"","cat_name":"\u7d30\u80de\u57f9\u990a\u30fb\u30a4\u30e1\u30fc\u30b8\u30f3\u30b0","category_nicename":"cell","category_parent":0}],"tag_info":[{"term_id":23,"name":"\u7d30\u80de\u57f9\u990a","slug":"cell-culture","term_group":0,"term_taxonomy_id":23,"taxonomy":"post_tag","description":"","parent":0,"count":64,"filter":"raw","meta":[]}],"jetpack-related-posts":[{"id":25608,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/cell-culture-basic-cell-culture-bpg-26026\/","url_meta":{"origin":495,"position":0},"title":"\u3010\u7b2c3\u56de\u3011Gibco\u57f9\u5730 60\u5e74\u306e\u30a4\u30ce\u30d9\u30fc\u30b7\u30e7\u30f3\u3002\u7d30\u80de\u57f9\u990a\u306e\u6b74\u53f2\u306f\u57f9\u5730\u306e\u6b74\u53f2\u3002","author":"LatB Staff","date":"2026\u5e7410\u67087\u65e5","format":false,"excerpt":"\u3053\u306e\u30d6\u30ed\u30b0\u3067\u306f\u3001\u30d0\u30a4\u30aa\u30d7\u30ed\u30c0\u30af\u30b7\u30e7\u30f3\u30c1\u30fc\u30e0\u304c\u533b\u85ac\u54c1\u88fd\u9020\u306b\u95a2\u9023\u3059\u308b\u3055\u307e\u3056\u307e\u306a\u30c8\u30d4\u30c3\u30af\u3092\u30b7\u30ea\u30fc\u30ba\u3067\u3054\u7d39\u4ecb\u2026","rel":"","context":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","block_context":{"text":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/mol-bio\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/08\/cell-culture-basic-cell-culture-bpg-26026_eyecatch.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/08\/cell-culture-basic-cell-culture-bpg-26026_eyecatch.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/08\/cell-culture-basic-cell-culture-bpg-26026_eyecatch.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/08\/cell-culture-basic-cell-culture-bpg-26026_eyecatch.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/08\/cell-culture-basic-cell-culture-bpg-26026_eyecatch.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/08\/cell-culture-basic-cell-culture-bpg-26026_eyecatch.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":23098,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/cell-culture-cell-culture-basic-bid-ts-mbr-25059\/","url_meta":{"origin":495,"position":1},"title":"\u7d30\u80de\u57f9\u990a\u7528\u306e\u57f9\u5730\uff5e\u521d\u5fc3\u8005\u5fc5\u898b\uff01\u7d30\u80de\u57f9\u990a\u306e\u5b8c\u5168\u30b5\u30dd\u30fc\u30c8\u30ac\u30a4\u30c9 \u305d\u306e4","author":"LatB Staff","date":"2025\u5e7410\u67082\u65e5","format":false,"excerpt":"\u300c\u7d30\u80de\u57f9\u990a\u306e\u5b8c\u5168\u30b5\u30dd\u30fc\u30c8\u30ac\u30a4\u30c9\u300d\u306f\u3001\u7d30\u80de\u57f9\u990a\u306b\u521d\u3081\u3066\u6311\u6226\u3055\u308c\u308b\u65b9\u3084\u3001\u307e\u3060\u7d4c\u9a13\u306e\u6d45\u3044\u65b9\u306b\u5411\u3051\u3066\u3001\u57fa\u790e\u77e5\u2026","rel":"","context":"\u7d30\u80de\u57f9\u990a\u30fb\u30a4\u30e1\u30fc\u30b8\u30f3\u30b0","block_context":{"text":"\u7d30\u80de\u57f9\u990a\u30fb\u30a4\u30e1\u30fc\u30b8\u30f3\u30b0","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/cell\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/09\/cell-culture-cell-culture-basic-bid-ts-mbr-25059_eycatch.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/09\/cell-culture-cell-culture-basic-bid-ts-mbr-25059_eycatch.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/09\/cell-culture-cell-culture-basic-bid-ts-mbr-25059_eycatch.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/09\/cell-culture-cell-culture-basic-bid-ts-mbr-25059_eycatch.jpg?resize=700%2C400&ssl=1 2x"},"classes":[]},{"id":24152,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/cell-culture-protein-expression-bid-ts-mbr-25074\/","url_meta":{"origin":495,"position":2},"title":"\u30bf\u30f3\u30d1\u30af\u7523\u751f\u3084\u30a6\u30a4\u30eb\u30b9\u7523\u751f\u3092\u76ee\u7684\u3068\u3057\u305f\u9ad8\u5bc6\u5ea6\u7d30\u80de\u57f9\u990a\u30b7\u30b9\u30c6\u30e0\u5c0e\u5165\u306e\u7b2c\u4e00\u6b69\uff1a\u7d30\u80de\u682a\u306e\u7d99\u4ee3\u3068\u51cd\u7d50\u4fdd\u5b58\u7de8","author":"LatB Staff","date":"2025\u5e7412\u67083\u65e5","format":false,"excerpt":"\u9ad8\u5bc6\u5ea6\u7d30\u80de\u57f9\u990a\u30b7\u30b9\u30c6\u30e0\u3067\u306f\u3001\u5c02\u7528\u306e\u6d6e\u904a\u7d30\u80de\u682a\u3092\u7528\u3044\u3066\u6c7a\u3081\u3089\u308c\u305f\u624b\u9806\u3067\u57f9\u990a\u3057\u307e\u3059\u3002\u5b89\u5b9a\u7684\u306b\u904b\u7528\u3059\u308b\u305f\u3081\u2026","rel":"","context":"\u7d30\u80de\u57f9\u990a\u30fb\u30a4\u30e1\u30fc\u30b8\u30f3\u30b0","block_context":{"text":"\u7d30\u80de\u57f9\u990a\u30fb\u30a4\u30e1\u30fc\u30b8\u30f3\u30b0","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/cell\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/11\/cell-culture-protein-expression-bid-ts-mbr-25074_eycatch.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/11\/cell-culture-protein-expression-bid-ts-mbr-25074_eycatch.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/11\/cell-culture-protein-expression-bid-ts-mbr-25074_eycatch.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/11\/cell-culture-protein-expression-bid-ts-mbr-25074_eycatch.jpg?resize=700%2C400&ssl=1 2x"},"classes":[]},{"id":23457,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/cell-culture-cell-culture-basic-bid-ts-mbr-25063\/","url_meta":{"origin":495,"position":3},"title":"\u7d30\u80de\u57f9\u990a\u7528\u306e\u8840\u6e05\uff08FBS\uff09\u3068\u6297\u751f\u7269\u8cea\u306e\u30dd\u30a4\u30f3\u30c8\uff5e\u7d30\u80de\u57f9\u990a\u306e\u5b8c\u5168\u30b5\u30dd\u30fc\u30c8\u30ac\u30a4\u30c9 \u305d\u306e5","author":"LatB Staff","date":"2025\u5e7410\u670822\u65e5","format":false,"excerpt":"\u300c\u7d30\u80de\u57f9\u990a\u306e\u5b8c\u5168\u30b5\u30dd\u30fc\u30c8\u30ac\u30a4\u30c9\u300d\u306f\u3001\u7d30\u80de\u57f9\u990a\u306b\u521d\u3081\u3066\u6311\u6226\u3059\u308b\u65b9\u3084\u3001\u307e\u3060\u7d4c\u9a13\u306e\u6d45\u3044\u65b9\u306b\u5411\u3051\u3066\u3001\u57fa\u790e\u77e5\u8b58\u2026","rel":"","context":"\u7d30\u80de\u57f9\u990a\u30fb\u30a4\u30e1\u30fc\u30b8\u30f3\u30b0","block_context":{"text":"\u7d30\u80de\u57f9\u990a\u30fb\u30a4\u30e1\u30fc\u30b8\u30f3\u30b0","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/cell\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/10\/cell-culture-cell-culture-basic-bid-ts-mbr-25063_eyecatch-scaled.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/10\/cell-culture-cell-culture-basic-bid-ts-mbr-25063_eyecatch-scaled.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/10\/cell-culture-cell-culture-basic-bid-ts-mbr-25063_eyecatch-scaled.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/10\/cell-culture-cell-culture-basic-bid-ts-mbr-25063_eyecatch-scaled.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/10\/cell-culture-cell-culture-basic-bid-ts-mbr-25063_eyecatch-scaled.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/10\/cell-culture-cell-culture-basic-bid-ts-mbr-25063_eyecatch-scaled.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":23765,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/cell-culture-cell-count-bid-ts-mbr-25065\/","url_meta":{"origin":495,"position":4},"title":"\u3010\u3084\u3063\u3066\u307f\u305f\u3011\u51dd\u96c6\u3057\u3084\u3059\u3044\u7d30\u80de\u3092\u3042\u306e\u624b\u3053\u306e\u624b\u3067\u307b\u3050\u3057\u3066\u307f\u305f","author":"LatB Staff","date":"2025\u5e7411\u67084\u65e5","format":false,"excerpt":"\u7d30\u80de\u57f9\u990a\u5b9f\u9a13\u306b\u304a\u3044\u3066\u3001\u7d30\u80de\u6570\u3084\u751f\u7d30\u80de\u7387\u30fb\u6b7b\u7d30\u80de\u7387\u306e\u6e2c\u5b9a\uff08\u3044\u308f\u3086\u308b\u30bb\u30eb\u30ab\u30a6\u30f3\u30c8\uff09\u306f\u91cd\u8981\u306a\u30b9\u30c6\u30c3\u30d7\u3067\u3059\u3002\u2026","rel":"","context":"\u7d30\u80de\u57f9\u990a\u30fb\u30a4\u30e1\u30fc\u30b8\u30f3\u30b0","block_context":{"text":"\u7d30\u80de\u57f9\u990a\u30fb\u30a4\u30e1\u30fc\u30b8\u30f3\u30b0","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/cell\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/10\/cell-culture-cell-count-bid-ts-mbr-25065_eyecatch-scaled.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/10\/cell-culture-cell-count-bid-ts-mbr-25065_eyecatch-scaled.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/10\/cell-culture-cell-count-bid-ts-mbr-25065_eyecatch-scaled.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/10\/cell-culture-cell-count-bid-ts-mbr-25065_eyecatch-scaled.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/10\/cell-culture-cell-count-bid-ts-mbr-25065_eyecatch-scaled.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/10\/cell-culture-cell-count-bid-ts-mbr-25065_eyecatch-scaled.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":25540,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/cloning-cell-separation-bid-ts-mbr-26023\/","url_meta":{"origin":495,"position":5},"title":"\u5927\u8178\u83cc\u306e\u98fc\u3044\u65b92\uff5e\u5b9f\u969b\u306b\u57f9\u990a\u3057\u3066\u307f\u3088\u3046","author":"LatB Staff","date":"2026\u5e748\u670826\u65e5","format":false,"excerpt":"\u30d6\u30ed\u30b0\u300c\u5927\u8178\u83cc\u306e\u98fc\u3044\u65b9\uff5e\u5b9f\u9a13\u306b\u5fc5\u8981\u306a\u8a2d\u5099\u3092\u305d\u308d\u3048\u3088\u3046\u300d\u3067\u306f\u3001\u30af\u30ed\u30fc\u30cb\u30f3\u30b0\u3084\u7d44\u307f\u63db\u3048\u30bf\u30f3\u30d1\u30af\u8cea\u767a\u73fe\u306e\u7528\u2026","rel":"","context":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","block_context":{"text":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/mol-bio\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/08\/cloning-cell-separation-bid-ts-mbr-26023_eyecatch.png?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/08\/cloning-cell-separation-bid-ts-mbr-26023_eyecatch.png?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/08\/cloning-cell-separation-bid-ts-mbr-26023_eyecatch.png?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/08\/cloning-cell-separation-bid-ts-mbr-26023_eyecatch.png?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/08\/cloning-cell-separation-bid-ts-mbr-26023_eyecatch.png?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/08\/cloning-cell-separation-bid-ts-mbr-26023_eyecatch.png?resize=1400%2C800&ssl=1 4x"},"classes":[]}],"jetpack_sharing_enabled":true,"amp_enabled":true,"jetpack_featured_media_url":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/cell-culture-environment-title.jpg","_links":{"self":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/posts\/495","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/users\/988"}],"replies":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/comments?post=495"}],"version-history":[{"count":0,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/posts\/495\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/media\/2784"}],"wp:attachment":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/media?parent=495"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/categories?post=495"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/tags?post=495"},{"taxonomy":"division","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/division?post=495"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}