{"id":499,"date":"2016-11-01T00:00:00","date_gmt":"2016-11-01T00:00:00","guid":{"rendered":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/cell-morphology-basic\/"},"modified":"2024-12-25T16:27:35","modified_gmt":"2024-12-25T07:27:35","slug":"cell-morphology-basic","status":"publish","type":"post","link":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/cell-morphology-basic\/","title":{"rendered":"\u3072\u3068\u76ee\u3067\u5206\u304b\u308b\uff01\u57f9\u990a\u7d30\u80de\u306e\u5f62\u614b\u5b66\u5165\u9580"},"content":{"rendered":"<h2>\u306f\u3058\u3081\u306b<\/h2>\n<p><strong>\u57f9\u990a\u7269\u4e2d\u306e\u7d30\u80de\u306e\u5f62\u614b\uff08\u3059\u306a\u308f\u3061\u3001\u7d30\u80de\u306e\u5f62\u304a\u3088\u3073\u5916\u89b3\uff09\u3092\u5b9a\u671f\u7684\u306b\u89b3\u5bdf\u3059\u308b\u3053\u3068\u306f\u3001\u7d30\u80de\u57f9\u990a\u5b9f\u9a13\u306e\u6210\u529f\u306b\u4e0d\u53ef\u6b20\u3067\u3059\u3002<\/strong>\u7d30\u80de\u306e\u5065\u5168\u306a\u72b6\u614b\u3092\u78ba\u8a8d\u3059\u308b\u3053\u3068\u306b\u52a0\u3048\u3001\u7d30\u80de\u3092\u53d6\u308a\u6271\u3046\u6bce\u306b\u3001<strong>\u76ee\u8996\u307e\u305f\u306f\u9855\u5fae\u93e1\u306b\u3088\u3063\u3066\u7d30\u80de\u3092\u691c\u67fb\u3059\u308b\u3053\u3068\u306b\u3088\u308a\u3001\u6c5a\u67d3\u3092\u65e9\u671f\u306b\u767a\u898b\u3057\u3001\u5b9f\u9a13\u5ba4\u5468\u8fba\u306e\u4ed6\u306e\u7d30\u80de\u57f9\u990a\u7cfb\u306b\u6c5a\u67d3\u304c\u62e1\u6563\u3059\u308b\u306e\u3092\u9632\u3050\u3053\u3068\u304c\u3067\u304d\u307e\u3059\u3002<\/strong><\/p>\n<p>\u7d30\u80de\u306e\u52a3\u5316\u306e\u5fb4\u5019\u306b\u306f\u3001\u6838\u306e\u5468\u308a\u306e\u7c92\u5b50\u5f62\u6210\u3001\u7d30\u80de\u306e\u57fa\u8cea\u304b\u3089\u306e\u5265\u96e2\u304a\u3088\u3073\u7d30\u80de\u8cea\u306e\u7a7a\u7832\u5316\u306a\u3069\u304c\u542b\u307e\u308c\u307e\u3059\u3002\u52a3\u5316\u306e\u5fb4\u5019\u306f\u3001\u57f9\u990a\u7cfb\u306e\u6c5a\u67d3\u3001\u7d30\u80de\u7cfb\u306e\u8001\u5316\u3001\u307e\u305f\u306f\u57f9\u5730\u4e2d\u306e\u6bd2\u6027\u7269\u8cea\u306e\u5b58\u5728\u306a\u3069\u69d8\u3005\u306a\u7406\u7531\u306b\u3088\u3063\u3066\u5f15\u304d\u8d77\u3053\u3055\u308c\u3066\u3044\u308b\u53ef\u80fd\u6027\u304c\u3042\u308a\u307e\u3059\u3002\u307e\u305f\u5358\u306b\u3001\u57f9\u5730\u306e\u4ea4\u63db\u304c\u5fc5\u8981\u3067\u3042\u308b\u3053\u3068\u3092\u793a\u3057\u3066\u3044\u308b\u5834\u5408\u3082\u3042\u308a\u307e\u3059\u3002\u52a3\u5316\u304c\u9032\u307f\u3059\u304e\u308b\u3068\u3001\u56de\u5fa9\u304c\u4e0d\u53ef\u80fd\u3067\u3059\u3002<\/p>\n<p><strong>\u4eca\u56de\u306f\u3001\u54fa\u4e73\u985e\u7d30\u80de\u3068\u6606\u866b\u7d30\u80de\u306e\u3044\u304f\u3064\u304b\u3092\u30d4\u30c3\u30af\u30a2\u30c3\u30d7\u3057\u3001\u305d\u306e\u5f62\u614b\u3092\u3054\u7d39\u4ecb\u3057\u307e\u3059\u3002<\/strong><\/p>\n<h2>\u54fa\u4e73\u985e\u7d30\u80de<\/h2>\n<h3>\u54fa\u4e73\u985e\u7d30\u80de\u306e\u5f62\u614b\u306e\u30d0\u30ea\u30a8\u30fc\u30b7\u30e7\u30f3<\/h3>\n<p>\u54fa\u4e73\u985e\u7d30\u80de\u306e\u5927\u90e8\u5206\u306f\u3001\u305d\u306e\u5f62\u614b\u306b\u3088\u3063\u3066\u30013\u7a2e\u985e\u306e\u57fa\u672c\u7684\u306a\u30ab\u30c6\u30b4\u30ea\u30fc\u306b\u5206\u985e\u3055\u308c\u307e\u3059\u3002<\/p>\n<ul>\n<li><strong>\u7dda\u7dad\u82bd\uff08\u307e\u305f\u306f\u7dda\u7dad\u82bd\u69d8\uff09\u7d30\u80de<\/strong>\u306f\u3001\u4e8c\u6975\u6027\u307e\u305f\u306f\u591a\u6975\u6027\u3067\u3042\u308a\u3001\u7d30\u9577\u3044\u5f62\u72b6\u3092\u6709\u3057\u307e\u3059\u3002\u7d30\u80de\u306f\u7269\u8cea\u306b\u63a5\u7740\u3057\u3066\u6210\u9577\u3057\u307e\u3059\u3002<\/li>\n<li><strong>\u4e0a\u76ae\u69d8\u7d30\u80de<\/strong>\u306f\u3001\u3088\u308a\u898f\u5247\u7684\u306a\u591a\u89d2\u5f62\u306e\u5f62\u72b6\u3092\u6709\u3057\u3001\u6591\u70b9\u72b6\u306b\u30b3\u30ed\u30cb\u30fc\u3092\u5f62\u6210\u3057\u306a\u304c\u3089\u3001\u57fa\u8cea\u306b\u63a5\u7740\u3057\u3066\u6210\u9577\u3057\u307e\u3059\u3002<\/li>\n<li><strong>\u30ea\u30f3\u30d1\u82bd\u7403\u69d8\u7d30\u80de<\/strong>\u306f\u3001\u7403\u5f62\u306e\u5f62\u72b6\u3092\u6709\u3057\u3001\u4e00\u822c\u306b\u3001\u57fa\u8cea\u306b\u63a5\u7740\u3059\u308b\u3053\u3068\u306a\u304f\u3001\u6d6e\u904a\u72b6\u614b\u3067\u6210\u9577\u3057\u307e\u3059\u3002<\/li>\n<\/ul>\n<p>\u4e0a\u8a18\u306e\u57fa\u672c\u7684\u306a\u30ab\u30c6\u30b4\u30ea\u30fc\u306b\u52a0\u3048\u3001\u5bbf\u4e3b\u4e2d\u3067\u306e\u7279\u5b9a\u306e\u5f79\u5272\u306b\u7279\u7570\u7684\u306a\u5f62\u614b\u5b66\u7684\u7279\u5fb4\u3092\u793a\u3059\u7d30\u80de\u3082\u5b58\u5728\u3057\u307e\u3059\u3002<\/p>\n<p><strong>\u795e\u7d4c\u7d30\u80de<\/strong>\u306b\u306f\u3001\u7570\u306a\u308b\u5f62\u72b6\u304a\u3088\u3073\u5927\u304d\u3055\u306e\u7d30\u80de\u304c\u5b58\u5728\u3057\u307e\u3059\u304c\u3001\u5927\u307e\u304b\u306b\u306f\u3001<strong>\u4fe1\u53f7\u3092\u9577\u8ddd\u96e2\u306b\u4f1d\u9054\u3059\u308b\u305f\u3081\u306e\u9577\u3044\u8ef8\u7d22\u3092\u6709\u3059\u308b\u2160\u578b\u7d30\u80de<\/strong>\u3068\u3001<strong>\u8ef8\u7d22\u3092\u6301\u305f\u306a\u3044\u2161\u578b\u7d30\u80de<\/strong>\u306e\u30012\u7a2e\u985e\u306e\u57fa\u672c\u7684\u306a\u30ab\u30c6\u30b4\u30ea\u30fc\u306b\u5206\u985e\u3067\u304d\u307e\u3059\u3002\u5178\u578b\u7684\u306a\u795e\u7d4c\u7d30\u80de\u3067\u306f\u3001\u591a\u304f\u306e\u679d\u5206\u304b\u308c\u3092\u6301\u3064\u3001\u6a39\u72b6\u7a81\u8d77\u3068\u547c\u3070\u308c\u308b\u7a81\u8d77\u304c\u7d30\u80de\u4f53\u304b\u3089\u51fa\u3066\u3044\u307e\u3059\u3002\u795e\u7d4c\u7d30\u80de\u306f\u3001\u6a39\u72b6\u7a81\u8d77\u3068\u8ef8\u7d22\u304c\u540c\u4e00\u306e\u7a81\u8d77\u304b\u3089\u51fa\u3066\u3044\u308b\u5834\u5408\u306b\u306f\u3001\u5358\u6975\u6027\u307e\u305f\u306f\u64ec\u4f3c\u5358\u6975\u6027\u3001\u6a39\u72b6\u7a81\u8d77\u3068\u8ef8\u7d22\u304c\u795e\u7d4c\u7d30\u80de\u4f53\uff08\u7d30\u80de\u306e\u4e2d\u306e\u6838\u3092\u6709\u3059\u308b\u90e8\u5206\uff09\u306e\u53cd\u5bfe\u5074\u304b\u3089\u51fa\u3066\u3044\u308b\u5834\u5408\u306b\u306f\u4e8c\u6975\u6027\u30012\u3064\u4ee5\u4e0a\u306e\u6a39\u72b6\u7a81\u8d77\u3092\u6709\u3059\u308b\u5834\u5408\u306b\u306f\u591a\u6975\u6027\u3068\u306a\u308a\u307e\u3059\u3002<\/p>\n<h3>293\u7d30\u80de\u306e\u5f62\u614b\u5b66<\/h3>\n<p><strong>293\u7d30\u80de\u7cfb\u306f\u3001\u521d\u4ee3\u57f9\u990a\u30d2\u30c8\u80da\u6027\u814e\u81d3\u7d30\u80de\u304b\u3089\u78ba\u7acb\u3055\u308c\u305f\u6c38\u4e45\u7d30\u80de\u7cfb<\/strong>\u3067\u3001\u526a\u65ad\u3055\u308c\u305f\u30d2\u30c8\u30a2\u30c7\u30ce\u30a6\u30a4\u30eb\u30b95\u578bDNA\u3067\u5f62\u8cea\u8ee2\u63db\u3055\u308c\u3066\u3044\u307e\u3059\u3002\u3053\u306e\u7d30\u80de\u7cfb\u306b\u767a\u73fe\u3057\u3066\u3044\u308b\u30a2\u30c7\u30ce\u30a6\u30a4\u30eb\u30b9\u907a\u4f1d\u5b50\u306b\u3088\u308a\u3001<strong>\u7d30\u80de\u306f\u6975\u3081\u3066\u9ad8\u30ec\u30d9\u30eb\u306e\u7d44\u63db\u3048\u30bf\u30f3\u30d1\u30af\u8cea\u3092\u751f\u7523\u3059\u308b\u3053\u3068\u304c\u53ef\u80fd<\/strong>\u3067\u3059\u3002\u30b5\u30fc\u30e2\u30d5\u30a3\u30c3\u30b7\u30e3\u30fc\u30b5\u30a4\u30a8\u30f3\u30c6\u30a3\u30d5\u30a3\u30c3\u30af\u3067\u306f\u3001\u7121\u8840\u6e05\u57f9\u5730\u4e2d\u3067\u306e\u9ad8\u6fc3\u5ea6\u306e\u6d6e\u904a\u57f9\u990a\u306b\u9069\u5fdc\u3059\u308b\u7d30\u80de\u7cfb\u3092\u542b\u3080\u3001\u6570\u7a2e\u985e\u306e293\u7d30\u80de\u7cfb\u3092\u63d0\u4f9b\u3057\u3066\u3044\u307e\u3059\u3002\u3055\u3089\u306b\u8a73\u3057\u3044\u60c5\u5831\u306b\u95a2\u3057\u3066\u306f\u3001\u5f53\u793e\u306e<a href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/life-science\/cell-culture\/mammalian-cell-culture.html?CID=bid_clb_cce_r04_jp_cp0000_pjt0000_bid00000_0so_blg_op_awa_oc_s00_cc6_Social_LAB\" target=\"_blank\" rel=\"noopener noreferrer\">\u30a6\u30a7\u30d6\u30b5\u30a4\u30c8\u4e0a\u306e\u54fa\u4e73\u985e\u7d30\u80de\u306e\u30da\u30fc\u30b8<\/a>\u3092\u3054\u53c2\u7167\u304f\u3060\u3055\u3044\u3002<\/p>\n<p>\u4e0b\u56f3\u306e\u4f4d\u76f8\u30b3\u30f3\u30c8\u30e9\u30b9\u30c8\u753b\u50cf\u306f\u3001<strong>\u63a5\u7740\u57f9\u990a\u306e80%\u30b3\u30f3\u30d5\u30eb\u30a8\u30f3\u30c8\u72b6\u614b\uff08\u56f31\uff09<\/strong>\u304a\u3088\u3073<strong>\u6d6e\u904a\u57f9\u990a\uff08\u56f32\uff09<\/strong>\u306b\u304a\u3051\u308b\u5065\u5168\u306a293\u7d30\u80de\u306e\u5f62\u614b\u3092\u793a\u3057\u3066\u3044\u307e\u3059\u3002\u63a5\u7740\u6027\u54fa\u4e73\u985e\u7d30\u80de\u306f\u3001\u30b3\u30f3\u30d5\u30eb\u30a8\u30f3\u30c8\u306b\u9054\u3059\u308b\u524d\u306e\u3001\u5bfe\u6570\u5897\u6b96\u671f\u306b\u690d\u3048\u7d99\u304e\u3059\u308b\u5fc5\u8981\u304c\u3042\u308b\u3053\u3068\u306b\u6ce8\u610f\u3057\u3066\u304f\u3060\u3055\u3044\u3002<\/p>\n<div id=\"attachment_1456\" style=\"width: 1039px\" class=\"wp-caption aligncenter\"><a href=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/cell-morphology-basic-fig1.png\" rel=\"attachment wp-att-1456\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-1456\" class=\"size-full wp-image-1456\" src=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/cell-morphology-basic-fig1.png\" alt=\"cell-morphology-basic-fig1\" width=\"1029\" height=\"430\" \/><\/a><p id=\"caption-attachment-1456\" class=\"wp-caption-text\">\u56f31 \u63a5\u7740\u57f9\u990a\u306b\u304a\u3051\u308b\u5065\u5168\u306a293\u7d30\u80de\u306e\u4f4d\u76f8\u30b3\u30f3\u30c8\u30e9\u30b9\u30c8\u753b\u50cf\u3002\u7d30\u80de\u306f\u3001\u751f\u5b58\u7d30\u80de\u306e\u5bc6\u5ea6\u304c\u30015\u00d710<sup>4<\/sup>\u7d30\u80de\/cm<sup>2<\/sup>\u3068\u306a\u308b\u3088\u3046\u306b\u3001Gibco\u2122 293 SFM II \u57f9\u5730\u306b\u64ad\u7a2e\u3057\u3001\u52a0\u6e7f5%CO<sub>2<\/sub>\u74b0\u5883\u4e0b\u306e37\u00b0C\u306e\u30a4\u30f3\u30ad\u30e5\u30d9\u30fc\u30bf\u30fc\u4e2d\u3067\u5358\u5c64\u3068\u3057\u3066\u6210\u9577\u3055\u305b\u3066\u3044\u307e\u3059\u3002\u753b\u50cf\u306f\u64ad\u7a2e\u5f8c4\u65e5\u76ee\u306b\u3001\u305d\u308c\u305e\u308c10\u500d\uff08\u30d1\u30cd\u30ebA\uff09\u304a\u3088\u307320\u500d\uff08\u30d1\u30cd\u30ebB\uff09\u306e\u5bfe\u7269\u30ec\u30f3\u30ba\u3092\u7528\u3044\u3066\u5f97\u3089\u308c\u305f\u3082\u306e\u3067\u3059\u3002<\/p><\/div>\n<div id=\"attachment_1457\" style=\"width: 1043px\" class=\"wp-caption aligncenter\"><a href=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/cell-morphology-basic-fig2.png\" rel=\"attachment wp-att-1457\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-1457\" class=\"size-full wp-image-1457\" src=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/cell-morphology-basic-fig2.png\" alt=\"cell-morphology-basic-fig2\" width=\"1033\" height=\"432\" \/><\/a><p id=\"caption-attachment-1457\" class=\"wp-caption-text\">\u56f32 \u6d6e\u904a\u57f9\u990a\u306b\u3088\u3063\u3066\u6210\u9577\u3055\u305b\u305f\u3001\u5065\u5168\u306a293F\u7d30\u80de\u306e\u4f4d\u76f8\u30b3\u30f3\u30c8\u30e9\u30b9\u30c8\u753b\u50cf\u3002\u7d30\u80de\u306f\u3001\u751f\u5b58\u7d30\u80de\u306e\u5bc6\u5ea6\u304c\u30012\u00d710<sup>5<\/sup>\u7d30\u80de\/mL\u3068\u306a\u308b\u3088\u3046\u306b\u3001\u632f\u3068\u3046\u30d5\u30e9\u30b9\u30b3\u5185\u306eGibco\u2122 293 SFM II \u57f9\u5730\u306b\u64ad\u7a2e\u3057\u3001\u52a0\u6e7f5%CO<sub>2<\/sub>\u74b0\u5883\u4e0b\u306e37\u00b0C\u306e\u30a4\u30f3\u30ad\u30e5\u30d9\u30fc\u30bf\u30fc\u4e2d\u3067\u57f9\u990a\u3057\u307e\u3057\u305f\u3002\u64ad\u7a2e\u5f8c4\u65e5\u76ee\u306b\u3001\u7d30\u80de\u30921\uff1a3\u306e\u500d\u7387\u3067\u5e0c\u91c8\u3057\u300110\u500d\uff08\u30d1\u30cd\u30ebA\uff09\u304a\u3088\u307320\u500d\uff08\u30d1\u30cd\u30ebB\uff09\u306e\u5bfe\u7269\u30ec\u30f3\u30ba\u3092\u7528\u3044\u3066\u753b\u50cf\u3092\u5f97\u307e\u3057\u305f\u3002<\/p><\/div>\n<h2>\u6606\u866b\u7d30\u80de<\/h2>\n<h3>Sf21\u7d30\u80de\u306e\u5f62\u614b\u5b66<\/h3>\n<p><strong>Sf21\u7d30\u80de\uff08IPLB-Sf21-AE\uff09\u306f\u3001<i>Spodoptera frugiperda<\/i>\uff08\u30c4\u30de\u30b8\u30ed\u30af\u30b5\u30e8\u30c8\u30a6\uff09\u304b\u3089\u5206\u96e2\u3055\u308c\u305f\u5375\u5de3\u7d30\u80de<\/strong>\u3067\u3059\u3002\u7d30\u80de\u306e\u5f62\u72b6\u306f\u7403\u5f62\u3067\u3001\u5927\u304d\u3055\u306f\u5747\u4e00\u3067\u306f\u306a\u304f\u3001\u3084\u3084\u7c92\u72b6\u306e\u5916\u89b3\u3092\u5448\u3057\u3066\u3044\u307e\u3059\u3002Sf21\u7d30\u80de\u306f\u3001\u7d30\u80de\u30b9\u30c8\u30c3\u30af\u306e\u8fc5\u901f\u306a\u62e1\u5927\u3001\u30d0\u30ad\u30e5\u30ed\u30a6\u30a4\u30eb\u30b9\u30b9\u30c8\u30c3\u30af\u306e\u5897\u6b96\u304a\u3088\u3073\u7d44\u63db\u3048\u30bf\u30f3\u30d1\u30af\u8cea\u306e\u751f\u7523\u306e\u305f\u3081\u306b\u3001\u89e3\u51cd\u3057\u3066\u76f4\u63a5\u6d6e\u904a\u57f9\u990a\u306b\u4f7f\u7528\u3059\u308b\u3053\u3068\u304c\u53ef\u80fd\u3067\u3059\u3002Sf21\u7d30\u80de\u306f\u3001\u8868\u9762\u306b\u5805\u56fa\u306b\u63a5\u7740\u3059\u308b\u305f\u3081\u3001\u5f62\u8cea\u8ee2\u63db\u307e\u305f\u306f\u30d7\u30e9\u30fc\u30af\u30a2\u30c3\u30bb\u30a4\u5b9f\u9a13\u7528\u306b\u3001\u5358\u5c64\u3068\u3057\u3066\u4f7f\u7528\u3059\u308b\u3053\u3068\u304c\u53ef\u80fd\u3067\u3059\u3002<\/p>\n<p>\u4e0b\u56f3\u306e\u753b\u50cf\u306f\u3001\u5065\u5168\u306aSf21\u6606\u866b\u7d30\u80de\u306e\u3001<strong>\u6d6e\u904a\u57f9\u990a\uff08\u56f33\uff09<\/strong>\u304a\u3088\u3073<strong>\u63a5\u7740\u57f9\u990a\u306b\u304a\u3051\u308b\u30b3\u30f3\u30d5\u30eb\u30a8\u30f3\u30c8\u72b6\u614b\uff08\u56f34\uff09<\/strong>\u306e\u5f62\u614b\u3092\u793a\u3057\u3066\u3044\u307e\u3059\u3002\u6606\u866b\u7d30\u80de\u306f\u3001\u30b3\u30f3\u30d5\u30eb\u30a8\u30f3\u30c8\u306b\u9054\u3057\u305f\u6642\u70b9\u3067\u7d99\u4ee3\u3059\u308b\u5fc5\u8981\u304c\u3042\u308b\u3053\u3068\u306b\u6ce8\u610f\u3057\u3066\u304f\u3060\u3055\u3044\u3002<\/p>\n<div id=\"attachment_1458\" style=\"width: 1041px\" class=\"wp-caption aligncenter\"><a href=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/cell-morphology-basic-fig3.png\" rel=\"attachment wp-att-1458\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-1458\" class=\"size-full wp-image-1458\" src=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/cell-morphology-basic-fig3.png\" alt=\"cell-morphology-basic-fig3\" width=\"1031\" height=\"434\" \/><\/a><p id=\"caption-attachment-1458\" class=\"wp-caption-text\">\u56f33 \u6d6e\u904a\u57f9\u990a\u3057\u305f\u3001Sf21\u6606\u866b\u7d30\u80de\u306e\u4f4d\u76f8\u30b3\u30f3\u30c8\u30e9\u30b9\u30c8\u753b\u50cf\u3002\u7d30\u80de\u306f\u3001\u307e\u305a\u751f\u7d30\u80de\u306e\u5bc6\u5ea6\u304c\u30013\u00d710<sup>5<\/sup>\u7d30\u80de\/mL\u3068\u306a\u308b\u3088\u3046\u306b\u3001\u632f\u3068\u3046\u30d5\u30e9\u30b9\u30b3\u5185\u306eGibco\u2122 Sf-900 II SFM\u57f9\u5730\u306b\u64ad\u7a2e\u3057\u3001\u305d\u306e\u5f8c28\u00b0C\u306e\u3001\u975e\u52a0\u6e7f\u3067\u3001\u74b0\u5883\u5927\u6c17\u5236\u5fa1\u578b\u306e\u30a4\u30f3\u30ad\u30e5\u30d9\u30fc\u30bf\u30fc\u4e2d\u3067\u57f9\u990a\u3057\u307e\u3057\u305f\u3002\u753b\u50cf\u306f\u64ad\u7a2e\u5f8c3\u65e5\u76ee\u306b\u300110\u500d\uff08\u30d1\u30cd\u30ebA\uff09\u304a\u3088\u307320\u500d\uff08\u30d1\u30cd\u30ebB\uff09\u306e\u5bfe\u7269\u30ec\u30f3\u30ba\u3092\u7528\u3044\u3066\u5f97\u3089\u308c\u305f\u3082\u306e\u3067\u3059\u3002<\/p><\/div>\n<div id=\"attachment_1459\" style=\"width: 1047px\" class=\"wp-caption aligncenter\"><a href=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/cell-morphology-basic-fig4.png\" rel=\"attachment wp-att-1459\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-1459\" class=\"size-full wp-image-1459\" src=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/cell-morphology-basic-fig4.png\" alt=\"cell-morphology-basic-fig4\" width=\"1037\" height=\"430\" \/><\/a><p id=\"caption-attachment-1459\" class=\"wp-caption-text\">\u56f34 Gibco\u2122 293 SFM II\u57f9\u5730\u4e2d\u3001\u63a5\u7740\u6027\u306e\u5358\u5c64\u7d30\u80de\u3068\u3057\u3066\u6210\u9577\u3055\u305b\u305f\u3001Sf21\u6606\u866b\u7d30\u80de\u306e\u4f4d\u76f8\u30b3\u30f3\u30c8\u30e9\u30b9\u30c8\u753b\u50cf\u3002\u7d30\u80de\u306f\u3001\u751f\u7d30\u80de\u306e\u5bc6\u5ea6\u304c\u30015\u00d710<sup>4<\/sup>\u7d30\u80de\/cm<sup>2<\/sup>\u3068\u306a\u308b\u3088\u3046\u306b\u3001T-25\u30d5\u30e9\u30b9\u30b3\u5185\u306b\u64ad\u7a2e\u3057\u300128\u00b0C\u306e\u3001\u975e\u52a0\u6e7f\u3067\u3001\u74b0\u5883\u5927\u6c17\u5236\u5fa1\u578b\u306e\u30a4\u30f3\u30ad\u30e5\u30d9\u30fc\u30bf\u30fc\u4e2d\u3067\u3001\u5358\u5c64\u3068\u3057\u3066\u6210\u9577\u3055\u305b\u307e\u3057\u305f\u3002\u753b\u50cf\u306f\u64ad\u7a2e\u5f8c7\u65e5\u76ee\u306b\u3001\u57f9\u990a\u7d30\u80de\u304c\u30b3\u30f3\u30d5\u30eb\u30a8\u30f3\u30c8\u306b\u9054\u3057\u305f\u6642\u306b\u300110\u500d\uff08\u30d1\u30cd\u30ebA\uff09\u304a\u3088\u307320\u500d\uff08\u30d1\u30cd\u30ebB\uff09\u306e\u5bfe\u7269\u30ec\u30f3\u30ba\u3092\u7528\u3044\u3066\u5f97\u3089\u308c\u305f\u3082\u306e\u3067\u3059\u3002<\/p><\/div>\n<h3>Sf9\u7d30\u80de\u306e\u5f62\u614b\u5b66<\/h3>\n<p><strong>Sf9\u6606\u866b\u7d30\u80de\u7cfb\u306f\u3001\u89aa\u682a\u3067\u3042\u308b<i>Spodoptera frugiperda<\/i>\u7d30\u80de\u7cfb\u306eIPLB-Sf21-AE\u7d30\u80de\u7531\u6765\u306e\u30af\u30ed\u30fc\u30f3\u5206\u96e2\u682a<\/strong>\u3067\u3001\u30d0\u30ad\u30e5\u30ed\u30a6\u30a4\u30eb\u30b9\u767a\u73fe\u30b7\u30b9\u30c6\u30e0\uff08\u4f8b\uff1a <a href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/life-science\/protein-biology\/protein-expression\/insect-protein-expression\/bac-to-bac-baculovirus-expression-system.html?CID=bid_clb_cce_r04_jp_cp0000_pjt0000_bid00000_0so_blg_op_awa_oc_s00_cc6_Social_LAB\" target=\"_blank\" rel=\"noopener noreferrer\">Invitrogen\u2122 Bac-to-Bac\u2122<\/a>\u304a\u3088\u3073<a href=\"https:\/\/www.thermofisher.com\/order\/catalog\/product\/K85501?CID=bid_clb_cce_r04_jp_cp0000_pjt0000_bid00000_0so_blg_op_awa_oc_s00_cc6_Social_LAB\" target=\"_blank\" rel=\"noopener noreferrer\">Invitrogen\u2122 Bac-N-Blue\u2122\u767a\u73fe\u30b7\u30b9\u30c6\u30e0<\/a>\uff09\u304b\u3089\u306e<strong>\u7d44\u63db\u3048\u30bf\u30f3\u30d1\u30af\u8cea\u767a\u73fe\u7528\u306e\u5bbf\u4e3b\u3068\u3057\u3066\u306e\u4f7f\u7528\u306b\u9069\u3057\u3066\u3044\u307e\u3059<\/strong>\u3002\u6606\u866b\u7d30\u80de\u306f\u5f93\u6765\u3001\u975c\u7f6e\u57f9\u990a\u7cfb\u3067\u3001T\u578b\u30d5\u30e9\u30b9\u30b3\u304a\u3088\u3073\u8840\u6e05\u3092\u52a0\u3048\u305f\u57fa\u672c\u57f9\u5730\u3092\u4f7f\u7528\u3057\u3066\u57f9\u990a\u3055\u308c\u3066\u304d\u3066\u3044\u307e\u3059\u304c\u3001\u4e00\u822c\u306b\u6606\u866b\u7d30\u80de\u306f\u63a5\u7740\u4f9d\u5b58\u6027\u3067\u306f\u306a\u3044\u305f\u3081\u3001\u6d6e\u904a\u57f9\u990a\u7cfb\u3067\u3082\u5bb9\u6613\u306b\u7dad\u6301\u3059\u308b\u3053\u3068\u304c\u53ef\u80fd\u3067\u3059\u3002<\/p>\n<p>\u4e0b\u56f3\u306e\u753b\u50cf\u306f\u3001\u5065\u5168\u306aSf9\u6606\u866b\u7d30\u80de\u306e\u3001\u6d6e\u904a\u57f9\u990a\u304a\u3088\u3073\u63a5\u7740\u57f9\u990a\u306b\u304a\u3051\u308b\u5f62\u614b\u3092\u793a\u3057\u3066\u3044\u307e\u3059\u3002Sf9\u7d30\u80de\u306f\u3001\u8868\u9762\u306b\u5805\u56fa\u306b\u63a5\u7740\u3057\u3001\u5fae\u5c0f\u3067\u3057\u304b\u3082\u5927\u304d\u3055\u304c\u5747\u4e00\u3067\u3042\u308b\u305f\u3081\u3001\u6975\u3081\u3066\u3059\u3050\u308c\u305f\u5358\u5c64\u304a\u3088\u3073\u30d7\u30e9\u30fc\u30af\u306e\u5f62\u6210\u80fd\u3092\u793a\u3057\u307e\u3059\u3002<\/p>\n<div id=\"attachment_1460\" style=\"width: 1053px\" class=\"wp-caption aligncenter\"><a href=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/cell-morphology-basic-fig5.png\" rel=\"attachment wp-att-1460\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-1460\" class=\"size-full wp-image-1460\" src=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/cell-morphology-basic-fig5.png\" alt=\"cell-morphology-basic-fig5\" width=\"1043\" height=\"438\" \/><\/a><p id=\"caption-attachment-1460\" class=\"wp-caption-text\">\u56f35 \u6d6e\u904a\u57f9\u990a\u3057\u305f\u3001Sf9\u6606\u866b\u7d30\u80de\u306e\u4f4d\u76f8\u30b3\u30f3\u30c8\u30e9\u30b9\u30c8\u753b\u50cf\u3002\u7d30\u80de\u306f\u3001\u307e\u305a\u751f\u7d30\u80de\u306e\u5bc6\u5ea6\u304c\u30013\u00d710<sup>5<\/sup>\u7d30\u80de\/mL\u3068\u306a\u308b\u3088\u3046\u306b\u3001\u632f\u3068\u3046\u30d5\u30e9\u30b9\u30b3\u5185\u306eSf-900 II SFM\u57f9\u5730\u306b\u64ad\u7a2e\u3057\u3001\u305d\u306e\u5f8c28\u00b0C\u306e\u3001\u975e\u52a0\u6e7f\u3067\u74b0\u5883\u5927\u6c17\u5236\u5fa1\u578b\u306e\u30a4\u30f3\u30ad\u30e5\u30d9\u30fc\u30bf\u30fc\u4e2d\u3067\u57f9\u990a\u3057\u307e\u3057\u305f\u3002\u753b\u50cf\u306f\u64ad\u7a2e\u5f8c3\u65e5\u76ee\u306b\u300110\u500d\uff08\u30d1\u30cd\u30ebA\uff09\u304a\u3088\u307320\u500d\uff08\u30d1\u30cd\u30ebB\uff09\u306e\u5bfe\u7269\u30ec\u30f3\u30ba\u3092\u7528\u3044\u3066\u5f97\u3089\u308c\u305f\u3082\u306e\u3067\u3059\u3002<\/p><\/div>\n<div id=\"attachment_1461\" style=\"width: 1051px\" class=\"wp-caption aligncenter\"><a href=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/cell-morphology-basic-fig6-1.png\" rel=\"attachment wp-att-1461\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-1461\" class=\"size-full wp-image-1461\" src=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/cell-morphology-basic-fig6-1.png\" alt=\"cell-morphology-basic-fig6\" width=\"1041\" height=\"432\" \/><\/a><p id=\"caption-attachment-1461\" class=\"wp-caption-text\">\u56f36 293 SFM II\u57f9\u5730\u4e2d\u3001\u63a5\u7740\u6027\u306e\u5358\u5c64\u7d30\u80de\u3068\u3057\u3066\u6210\u9577\u3055\u305b\u305f\u3001Sf9\u6606\u866b\u7d30\u80de\u306e\u4f4d\u76f8\u30b3\u30f3\u30c8\u30e9\u30b9\u30c8\u753b\u50cf\u3002\u7d30\u80de\u306f\u3001\u751f\u7d30\u80de\u306e\u5bc6\u5ea6\u304c\u30015\u00d710<sup>4<\/sup>\u7d30\u80de\/cm<sup>2<\/sup>\u3068\u306a\u308b\u3088\u3046\u306b\u3001T-25\u30d5\u30e9\u30b9\u30b3\u5185\u306b\u64ad\u7a2e\u3057\u300128\u00b0C\u306e\u3001\u975e\u52a0\u6e7f\u3067\u901a\u5e38\u306e\u7a7a\u6c17\u3092\u7528\u3044\u308b\u30a4\u30f3\u30ad\u30e5\u30d9\u30fc\u30bf\u30fc\u4e2d\u3067\u3001\u5358\u5c64\u3068\u3057\u3066\u6210\u9577\u3055\u305b\u307e\u3057\u305f\u3002\u753b\u50cf\u306f\u64ad\u7a2e\u5f8c3\u65e5\u76ee\u306b\u300110\u500d\uff08\u30d1\u30cd\u30ebA\uff09\u304a\u3088\u307320\u500d\uff08\u30d1\u30cd\u30ebB\uff09\u306e\u5bfe\u7269\u30ec\u30f3\u30ba\u3092\u7528\u3044\u3066\u5f97\u3089\u308c\u305f\u3082\u306e\u3067\u3059\u3002<\/p><\/div>\n<h2>\u3010\u7121\u6599\u30c0\u30a6\u30f3\u30ed\u30fc\u30c9\u3011Gibco\u7d30\u80de\u57f9\u990a\u57fa\u790e\u30cf\u30f3\u30c9\u30d6\u30c3\u30af<\/h2>\n<p>\u7d30\u80de\u57f9\u990a\u306b\u95a2\u3059\u308b\u57fa\u790e\u60c5\u5831\u3092\u89e3\u8aac\u3057\u305f\u30cf\u30f3\u30c9\u30d6\u30c3\u30af\u3092\u3054\u7528\u610f\u3057\u3066\u3044\u307e\u3059\uff08\u65e5\u672c\u8a9e\u7248\u3001\u7d04100\u30da\u30fc\u30b8\uff09\u3002PDF\u30d5\u30a1\u30a4\u30eb\u306e\u30c0\u30a6\u30f3\u30ed\u30fc\u30c9\u3092\u3054\u5e0c\u671b\u306e\u65b9\u306f\u3001\u4e0b\u8a18\u30dc\u30bf\u30f3\u3088\u308a\u304a\u7533\u3057\u8fbc\u307f\u304f\u3060\u3055\u3044\u3002<\/p>\n<p><a class=\"btn btn-red\" href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/global\/forms\/gibco-cell-culture-basics-handbook-form.html?CID=bid_clb_cce_r04_jp_cp0000_pjt0000_bid00000_0so_blg_op_awa_oc_s00_cc6_Social_LAB\" target=\"_blank\" rel=\"noopener\">\u30c0\u30a6\u30f3\u30ed\u30fc\u30c9<\/a><\/p>\n<p>&nbsp;<\/p>\n<p>\u7814\u7a76\u7528\u306b\u306e\u307f\u4f7f\u7528\u3067\u304d\u307e\u3059\u3002\u8a3a\u65ad\u7528\u306b\u306f\u4f7f\u7528\u3044\u305f\u3060\u3051\u307e\u305b\u3093\u3002<\/p>\n","protected":false},"excerpt":{"rendered":"<p>\u57f9\u990a\u7269\u4e2d\u306e\u7d30\u80de\u306e\u5f62\u614b\uff08\u3059\u306a\u308f\u3061\u3001\u7d30\u80de\u306e\u5f62\u304a\u3088\u3073\u5916\u89b3\uff09\u3092\u5b9a\u671f\u7684\u306b\u89b3\u5bdf\u3059\u308b\u3053\u3068\u306f\u3001\u7d30\u80de\u57f9\u990a\u5b9f\u9a13\u306e\u6210\u529f\u306b\u4e0d\u53ef\u6b20\u3067\u3059\u3002\u76ee\u8996\u307e\u305f\u306f\u9855\u5fae\u93e1\u306b\u3088\u3063\u3066\u7d30\u80de\u3092\u691c\u67fb\u3059\u308b\u3053\u3068\u306b\u3088\u308a\u3001\u6c5a\u67d3\u3092\u65e9\u671f\u306b\u767a\u898b\u3057\u3001\u5b9f\u9a13\u5ba4\u5468\u8fba\u306e\u4ed6\u306e\u7d30\u80de\u57f9\u990a\u7cfb\u306b\u6c5a\u67d3\u304c\u62e1\u6563\u3059\u308b\u306e\u3092\u9632\u3050\u3053\u3068\u304c\u3067\u304d\u307e\u3059\u3002\u4eca\u56de\u306f\u3001\u54fa\u4e73\u985e\u7d30\u80de\u3068\u6606\u866b\u7d30\u80de\u306e\u3044\u304f\u3064\u304b\u3092\u30d4\u30c3\u30af\u30a2\u30c3\u30d7\u3057\u3001\u305d\u306e\u5f62\u614b\u3092\u3054\u7d39\u4ecb\u3057\u307e\u3059\u3002<\/p>\n","protected":false},"author":988,"featured_media":2806,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_monsterinsights_skip_tracking":false,"_genesis_hide_title":false,"_genesis_hide_breadcrumbs":false,"_genesis_hide_singular_image":false,"_genesis_hide_footer_widgets":false,"_genesis_custom_body_class":"","_genesis_custom_post_class":"","_genesis_layout":"","_jetpack_newsletter_access":"","_jetpack_dont_email_post_to_subs":false,"_jetpack_newsletter_tier_id":0,"_jetpack_memberships_contains_paywalled_content":false,"_jetpack_feature_clip_id":0,"_jetpack_memberships_contains_paid_content":false,"footnotes":"","jetpack_post_was_ever_published":false},"categories":[159],"tags":[23],"division":[],"class_list":["post-499","post","type-post","status-publish","format-standard","has-post-thumbnail","category-cell","tag-cell-culture","entry"],"_selected_authors":"","_selected_reviewers":"","acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v27.8 (Yoast SEO v27.8) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>\u3072\u3068\u76ee\u3067\u5206\u304b\u308b\uff01\u57f9\u990a\u7d30\u80de\u306e\u5f62\u614b\u5b66\u5165\u9580 - Learning at the Bench<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/cell-morphology-basic\/\" \/>\n<meta property=\"og:locale\" content=\"ja_JP\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"\u3072\u3068\u76ee\u3067\u5206\u304b\u308b\uff01\u57f9\u990a\u7d30\u80de\u306e\u5f62\u614b\u5b66\u5165\u9580\" \/>\n<meta property=\"og:description\" content=\"\u57f9\u990a\u7269\u4e2d\u306e\u7d30\u80de\u306e\u5f62\u614b\uff08\u3059\u306a\u308f\u3061\u3001\u7d30\u80de\u306e\u5f62\u304a\u3088\u3073\u5916\u89b3\uff09\u3092\u5b9a\u671f\u7684\u306b\u89b3\u5bdf\u3059\u308b\u3053\u3068\u306f\u3001\u7d30\u80de\u57f9\u990a\u5b9f\u9a13\u306e\u6210\u529f\u306b\u4e0d\u53ef\u6b20\u3067\u3059\u3002\u76ee\u8996\u307e\u305f\u306f\u9855\u5fae\u93e1\u306b\u3088\u3063\u3066\u7d30\u80de\u3092\u691c\u67fb\u3059\u308b\u3053\u3068\u306b\u3088\u308a\u3001\u6c5a\u67d3\u3092\u65e9\u671f\u306b\u767a\u898b\u3057\u3001\u5b9f\u9a13\u5ba4\u5468\u8fba\u306e\u4ed6\u306e\u7d30\u80de\u57f9\u990a\u7cfb\u306b\u6c5a\u67d3\u304c\u62e1\u6563\u3059\u308b\u306e\u3092\u9632\u3050\u3053\u3068\u304c\u3067\u304d\u307e\u3059\u3002\u4eca\u56de\u306f\u3001\u54fa\u4e73\u985e\u7d30\u80de\u3068\u6606\u866b\u7d30\u80de\u306e\u3044\u304f\u3064\u304b\u3092\u30d4\u30c3\u30af\u30a2\u30c3\u30d7\u3057\u3001\u305d\u306e\u5f62\u614b\u3092\u3054\u7d39\u4ecb\u3057\u307e\u3059\u3002\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/cell-morphology-basic\/\" \/>\n<meta property=\"og:site_name\" content=\"Learning at the Bench\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/ThermoFisherJapan\" \/>\n<meta property=\"article:published_time\" content=\"2016-11-01T00:00:00+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2024-12-25T07:27:35+00:00\" \/>\n<meta property=\"og:image\" content=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/cell-morphology-basic-title.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"1200\" \/>\n\t<meta property=\"og:image:height\" content=\"630\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"LATB Staff\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:creator\" content=\"@ThermoFisherJP\" \/>\n<meta name=\"twitter:site\" content=\"@ThermoFisherJP\" \/>\n<meta name=\"twitter:label1\" content=\"\u57f7\u7b46\u8005\" \/>\n\t<meta name=\"twitter:data1\" content=\"LATB Staff\" \/>\n\t<meta name=\"twitter:label2\" content=\"\u63a8\u5b9a\u8aad\u307f\u53d6\u308a\u6642\u9593\" \/>\n\t<meta name=\"twitter:data2\" content=\"11\u5206\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/cell-morphology-basic\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/cell-morphology-basic\\\/\"},\"author\":{\"name\":\"LATB Staff\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#\\\/schema\\\/person\\\/201e6a5abb838fa34e8ff0174b015d36\"},\"headline\":\"\u3072\u3068\u76ee\u3067\u5206\u304b\u308b\uff01\u57f9\u990a\u7d30\u80de\u306e\u5f62\u614b\u5b66\u5165\u9580\",\"datePublished\":\"2016-11-01T00:00:00+00:00\",\"dateModified\":\"2024-12-25T07:27:35+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/cell-morphology-basic\\\/\"},\"wordCount\":119,\"commentCount\":0,\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/cell-morphology-basic\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2019\\\/07\\\/cell-morphology-basic-title.jpg\",\"keywords\":[\"\u7d30\u80de\u57f9\u990a\"],\"articleSection\":[\"\u7d30\u80de\u57f9\u990a\u30fb\u30a4\u30e1\u30fc\u30b8\u30f3\u30b0\"],\"inLanguage\":\"ja\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/cell-morphology-basic\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/cell-morphology-basic\\\/\",\"url\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/cell-morphology-basic\\\/\",\"name\":\"\u3072\u3068\u76ee\u3067\u5206\u304b\u308b\uff01\u57f9\u990a\u7d30\u80de\u306e\u5f62\u614b\u5b66\u5165\u9580 - Learning at the Bench\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/cell-morphology-basic\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/cell-morphology-basic\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2019\\\/07\\\/cell-morphology-basic-title.jpg\",\"datePublished\":\"2016-11-01T00:00:00+00:00\",\"dateModified\":\"2024-12-25T07:27:35+00:00\",\"author\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#\\\/schema\\\/person\\\/201e6a5abb838fa34e8ff0174b015d36\"},\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/cell-morphology-basic\\\/#breadcrumb\"},\"inLanguage\":\"ja\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/cell-morphology-basic\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"ja\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/cell-morphology-basic\\\/#primaryimage\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2019\\\/07\\\/cell-morphology-basic-title.jpg\",\"contentUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2019\\\/07\\\/cell-morphology-basic-title.jpg\",\"width\":1200,\"height\":630,\"caption\":\"cell-morphology-basic-title\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/cell-morphology-basic\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"\u3072\u3068\u76ee\u3067\u5206\u304b\u308b\uff01\u57f9\u990a\u7d30\u80de\u306e\u5f62\u614b\u5b66\u5165\u9580\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#website\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/\",\"name\":\"Learning at the Bench\",\"description\":\"\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"ja\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#\\\/schema\\\/person\\\/201e6a5abb838fa34e8ff0174b015d36\",\"name\":\"LATB Staff\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"ja\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/8803277856c8b753feb4217dff0f9953327452df1a615c3c88b2f9864efb2ddd?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/8803277856c8b753feb4217dff0f9953327452df1a615c3c88b2f9864efb2ddd?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/8803277856c8b753feb4217dff0f9953327452df1a615c3c88b2f9864efb2ddd?s=96&d=mm&r=g\",\"caption\":\"LATB Staff\"},\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/author\\\/latbstaff\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"\u3072\u3068\u76ee\u3067\u5206\u304b\u308b\uff01\u57f9\u990a\u7d30\u80de\u306e\u5f62\u614b\u5b66\u5165\u9580 - Learning at the Bench","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/cell-morphology-basic\/","og_locale":"ja_JP","og_type":"article","og_title":"\u3072\u3068\u76ee\u3067\u5206\u304b\u308b\uff01\u57f9\u990a\u7d30\u80de\u306e\u5f62\u614b\u5b66\u5165\u9580","og_description":"\u57f9\u990a\u7269\u4e2d\u306e\u7d30\u80de\u306e\u5f62\u614b\uff08\u3059\u306a\u308f\u3061\u3001\u7d30\u80de\u306e\u5f62\u304a\u3088\u3073\u5916\u89b3\uff09\u3092\u5b9a\u671f\u7684\u306b\u89b3\u5bdf\u3059\u308b\u3053\u3068\u306f\u3001\u7d30\u80de\u57f9\u990a\u5b9f\u9a13\u306e\u6210\u529f\u306b\u4e0d\u53ef\u6b20\u3067\u3059\u3002\u76ee\u8996\u307e\u305f\u306f\u9855\u5fae\u93e1\u306b\u3088\u3063\u3066\u7d30\u80de\u3092\u691c\u67fb\u3059\u308b\u3053\u3068\u306b\u3088\u308a\u3001\u6c5a\u67d3\u3092\u65e9\u671f\u306b\u767a\u898b\u3057\u3001\u5b9f\u9a13\u5ba4\u5468\u8fba\u306e\u4ed6\u306e\u7d30\u80de\u57f9\u990a\u7cfb\u306b\u6c5a\u67d3\u304c\u62e1\u6563\u3059\u308b\u306e\u3092\u9632\u3050\u3053\u3068\u304c\u3067\u304d\u307e\u3059\u3002\u4eca\u56de\u306f\u3001\u54fa\u4e73\u985e\u7d30\u80de\u3068\u6606\u866b\u7d30\u80de\u306e\u3044\u304f\u3064\u304b\u3092\u30d4\u30c3\u30af\u30a2\u30c3\u30d7\u3057\u3001\u305d\u306e\u5f62\u614b\u3092\u3054\u7d39\u4ecb\u3057\u307e\u3059\u3002","og_url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/cell-morphology-basic\/","og_site_name":"Learning at the Bench","article_publisher":"https:\/\/www.facebook.com\/ThermoFisherJapan","article_published_time":"2016-11-01T00:00:00+00:00","article_modified_time":"2024-12-25T07:27:35+00:00","og_image":[{"width":1200,"height":630,"url":"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/cell-morphology-basic-title.jpg","type":"image\/jpeg"}],"author":"LATB Staff","twitter_card":"summary_large_image","twitter_creator":"@ThermoFisherJP","twitter_site":"@ThermoFisherJP","twitter_misc":{"\u57f7\u7b46\u8005":"LATB Staff","\u63a8\u5b9a\u8aad\u307f\u53d6\u308a\u6642\u9593":"11\u5206"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/cell-morphology-basic\/#article","isPartOf":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/cell-morphology-basic\/"},"author":{"name":"LATB Staff","@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#\/schema\/person\/201e6a5abb838fa34e8ff0174b015d36"},"headline":"\u3072\u3068\u76ee\u3067\u5206\u304b\u308b\uff01\u57f9\u990a\u7d30\u80de\u306e\u5f62\u614b\u5b66\u5165\u9580","datePublished":"2016-11-01T00:00:00+00:00","dateModified":"2024-12-25T07:27:35+00:00","mainEntityOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/cell-morphology-basic\/"},"wordCount":119,"commentCount":0,"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/cell-morphology-basic\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/cell-morphology-basic-title.jpg","keywords":["\u7d30\u80de\u57f9\u990a"],"articleSection":["\u7d30\u80de\u57f9\u990a\u30fb\u30a4\u30e1\u30fc\u30b8\u30f3\u30b0"],"inLanguage":"ja","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/cell-morphology-basic\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/cell-morphology-basic\/","url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/cell-morphology-basic\/","name":"\u3072\u3068\u76ee\u3067\u5206\u304b\u308b\uff01\u57f9\u990a\u7d30\u80de\u306e\u5f62\u614b\u5b66\u5165\u9580 - Learning at the Bench","isPartOf":{"@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/cell-morphology-basic\/#primaryimage"},"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/cell-morphology-basic\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/cell-morphology-basic-title.jpg","datePublished":"2016-11-01T00:00:00+00:00","dateModified":"2024-12-25T07:27:35+00:00","author":{"@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#\/schema\/person\/201e6a5abb838fa34e8ff0174b015d36"},"breadcrumb":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/cell-morphology-basic\/#breadcrumb"},"inLanguage":"ja","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/cell-morphology-basic\/"]}]},{"@type":"ImageObject","inLanguage":"ja","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/cell-morphology-basic\/#primaryimage","url":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/cell-morphology-basic-title.jpg","contentUrl":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/cell-morphology-basic-title.jpg","width":1200,"height":630,"caption":"cell-morphology-basic-title"},{"@type":"BreadcrumbList","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/cell-morphology-basic\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/"},{"@type":"ListItem","position":2,"name":"\u3072\u3068\u76ee\u3067\u5206\u304b\u308b\uff01\u57f9\u990a\u7d30\u80de\u306e\u5f62\u614b\u5b66\u5165\u9580"}]},{"@type":"WebSite","@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#website","url":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/","name":"Learning at the Bench","description":"","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"ja"},{"@type":"Person","@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#\/schema\/person\/201e6a5abb838fa34e8ff0174b015d36","name":"LATB Staff","image":{"@type":"ImageObject","inLanguage":"ja","@id":"https:\/\/secure.gravatar.com\/avatar\/8803277856c8b753feb4217dff0f9953327452df1a615c3c88b2f9864efb2ddd?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/8803277856c8b753feb4217dff0f9953327452df1a615c3c88b2f9864efb2ddd?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/8803277856c8b753feb4217dff0f9953327452df1a615c3c88b2f9864efb2ddd?s=96&d=mm&r=g","caption":"LATB Staff"},"url":"https:\/\/admin.acceleratingscience.com\/author\/latbstaff\/"}]}},"taxonomy_info":{"category":[{"value":159,"label":"\u7d30\u80de\u57f9\u990a\u30fb\u30a4\u30e1\u30fc\u30b8\u30f3\u30b0"}],"post_tag":[{"value":23,"label":"\u7d30\u80de\u57f9\u990a"}]},"featured_image_src_large":["https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/cell-morphology-basic-title-1024x538.jpg",760,399,true],"author_info":{"display_name":"LATB Staff","author_link":"https:\/\/admin.acceleratingscience.com\/author\/latbstaff\/"},"comment_info":0,"category_info":[{"term_id":159,"name":"\u7d30\u80de\u57f9\u990a\u30fb\u30a4\u30e1\u30fc\u30b8\u30f3\u30b0","slug":"cell","term_group":0,"term_taxonomy_id":159,"taxonomy":"category","description":"","parent":0,"count":104,"filter":"raw","meta":[],"cat_ID":159,"category_count":104,"category_description":"","cat_name":"\u7d30\u80de\u57f9\u990a\u30fb\u30a4\u30e1\u30fc\u30b8\u30f3\u30b0","category_nicename":"cell","category_parent":0}],"tag_info":[{"term_id":23,"name":"\u7d30\u80de\u57f9\u990a","slug":"cell-culture","term_group":0,"term_taxonomy_id":23,"taxonomy":"post_tag","description":"","parent":0,"count":65,"filter":"raw","meta":[]}],"jetpack-related-posts":[{"id":23765,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/cell-culture-cell-count-bid-ts-mbr-25065\/","url_meta":{"origin":499,"position":0},"title":"\u3010\u3084\u3063\u3066\u307f\u305f\u3011\u51dd\u96c6\u3057\u3084\u3059\u3044\u7d30\u80de\u3092\u3042\u306e\u624b\u3053\u306e\u624b\u3067\u307b\u3050\u3057\u3066\u307f\u305f","author":"LatB Staff","date":"2025\u5e7411\u67084\u65e5","format":false,"excerpt":"\u7d30\u80de\u57f9\u990a\u5b9f\u9a13\u306b\u304a\u3044\u3066\u3001\u7d30\u80de\u6570\u3084\u751f\u7d30\u80de\u7387\u30fb\u6b7b\u7d30\u80de\u7387\u306e\u6e2c\u5b9a\uff08\u3044\u308f\u3086\u308b\u30bb\u30eb\u30ab\u30a6\u30f3\u30c8\uff09\u306f\u91cd\u8981\u306a\u30b9\u30c6\u30c3\u30d7\u3067\u3059\u3002\u2026","rel":"","context":"\u7d30\u80de\u57f9\u990a\u30fb\u30a4\u30e1\u30fc\u30b8\u30f3\u30b0","block_context":{"text":"\u7d30\u80de\u57f9\u990a\u30fb\u30a4\u30e1\u30fc\u30b8\u30f3\u30b0","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/cell\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/10\/cell-culture-cell-count-bid-ts-mbr-25065_eyecatch-scaled.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/10\/cell-culture-cell-count-bid-ts-mbr-25065_eyecatch-scaled.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/10\/cell-culture-cell-count-bid-ts-mbr-25065_eyecatch-scaled.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/10\/cell-culture-cell-count-bid-ts-mbr-25065_eyecatch-scaled.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/10\/cell-culture-cell-count-bid-ts-mbr-25065_eyecatch-scaled.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/10\/cell-culture-cell-count-bid-ts-mbr-25065_eyecatch-scaled.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":24152,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/cell-culture-protein-expression-bid-ts-mbr-25074\/","url_meta":{"origin":499,"position":1},"title":"\u30bf\u30f3\u30d1\u30af\u7523\u751f\u3084\u30a6\u30a4\u30eb\u30b9\u7523\u751f\u3092\u76ee\u7684\u3068\u3057\u305f\u9ad8\u5bc6\u5ea6\u7d30\u80de\u57f9\u990a\u30b7\u30b9\u30c6\u30e0\u5c0e\u5165\u306e\u7b2c\u4e00\u6b69\uff1a\u7d30\u80de\u682a\u306e\u7d99\u4ee3\u3068\u51cd\u7d50\u4fdd\u5b58\u7de8","author":"LatB Staff","date":"2025\u5e7412\u67083\u65e5","format":false,"excerpt":"\u9ad8\u5bc6\u5ea6\u7d30\u80de\u57f9\u990a\u30b7\u30b9\u30c6\u30e0\u3067\u306f\u3001\u5c02\u7528\u306e\u6d6e\u904a\u7d30\u80de\u682a\u3092\u7528\u3044\u3066\u6c7a\u3081\u3089\u308c\u305f\u624b\u9806\u3067\u57f9\u990a\u3057\u307e\u3059\u3002\u5b89\u5b9a\u7684\u306b\u904b\u7528\u3059\u308b\u305f\u3081\u2026","rel":"","context":"\u7d30\u80de\u57f9\u990a\u30fb\u30a4\u30e1\u30fc\u30b8\u30f3\u30b0","block_context":{"text":"\u7d30\u80de\u57f9\u990a\u30fb\u30a4\u30e1\u30fc\u30b8\u30f3\u30b0","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/cell\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/11\/cell-culture-protein-expression-bid-ts-mbr-25074_eycatch.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/11\/cell-culture-protein-expression-bid-ts-mbr-25074_eycatch.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/11\/cell-culture-protein-expression-bid-ts-mbr-25074_eycatch.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/11\/cell-culture-protein-expression-bid-ts-mbr-25074_eycatch.jpg?resize=700%2C400&ssl=1 2x"},"classes":[]},{"id":25608,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/cell-culture-basic-cell-culture-bpg-26026\/","url_meta":{"origin":499,"position":2},"title":"\u3010\u7b2c3\u56de\u3011Gibco\u57f9\u5730 60\u5e74\u306e\u30a4\u30ce\u30d9\u30fc\u30b7\u30e7\u30f3\u3002\u7d30\u80de\u57f9\u990a\u306e\u6b74\u53f2\u306f\u57f9\u5730\u306e\u6b74\u53f2\u3002","author":"LatB Staff","date":"2026\u5e7410\u67087\u65e5","format":false,"excerpt":"\u3053\u306e\u30d6\u30ed\u30b0\u3067\u306f\u3001\u30d0\u30a4\u30aa\u30d7\u30ed\u30c0\u30af\u30b7\u30e7\u30f3\u30c1\u30fc\u30e0\u304c\u533b\u85ac\u54c1\u88fd\u9020\u306b\u95a2\u9023\u3059\u308b\u3055\u307e\u3056\u307e\u306a\u30c8\u30d4\u30c3\u30af\u3092\u30b7\u30ea\u30fc\u30ba\u3067\u3054\u7d39\u4ecb\u2026","rel":"","context":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","block_context":{"text":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/mol-bio\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/08\/cell-culture-basic-cell-culture-bpg-26026_eyecatch.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/08\/cell-culture-basic-cell-culture-bpg-26026_eyecatch.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/08\/cell-culture-basic-cell-culture-bpg-26026_eyecatch.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/08\/cell-culture-basic-cell-culture-bpg-26026_eyecatch.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/08\/cell-culture-basic-cell-culture-bpg-26026_eyecatch.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/08\/cell-culture-basic-cell-culture-bpg-26026_eyecatch.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":25723,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/cell-culture-basic-cell-culture-bpg-26031\/","url_meta":{"origin":499,"position":3},"title":"\u3010\u7b2c4\u56de\u3011CHO\u7d30\u80de\u682a\u958b\u767a\u3092\u3088\u308a\u8fc5\u901f\u306b\u2015\u9ad8\u751f\u7523\u6027\u30fb\u9577\u671f\u5b89\u5b9a\u6027\u30fb\u30b9\u30b1\u30fc\u30e9\u30d3\u30ea\u30c6\u30a3\u3092\u8a55\u4fa1\u3057\u305fCHOvantage GS CLD Kit","author":"LatB Staff","date":"2026\u5e7411\u67086\u65e5","format":false,"excerpt":"\u6297\u4f53\u533b\u85ac\u54c1\u306e\u958b\u767a\u3067\u306f\u3001\u76ee\u7684\u306e\u6297\u4f53\u3092\u300c\u305f\u304f\u3055\u3093\u4f5c\u308c\u308b\u300d\u7d30\u80de\u3092\u898b\u3064\u3051\u308b\u3060\u3051\u3067\u306f\u5341\u5206\u3067\u306f\u3042\u308a\u307e\u305b\u3093\u3002\u9ad8\u3044\u751f\u2026","rel":"","context":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","block_context":{"text":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/mol-bio\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/10\/cell-culture-basic-cell-culture-bpg-26031_eyecatch.png?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/10\/cell-culture-basic-cell-culture-bpg-26031_eyecatch.png?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/10\/cell-culture-basic-cell-culture-bpg-26031_eyecatch.png?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/10\/cell-culture-basic-cell-culture-bpg-26031_eyecatch.png?resize=700%2C400&ssl=1 2x"},"classes":[]},{"id":25472,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/exosome-ts-r-25067\/","url_meta":{"origin":499,"position":4},"title":"\u3010\u7b2c7\u56de\u3011 \u30a8\u30af\u30bd\u30bd\u30fc\u30e0\u30b5\u30d6\u30bf\u30a4\u30d7\u306e\u5206\u753b\u306e\u6982\u8981","author":"LatB Staff","date":"2026\u5e748\u670813\u65e5","format":false,"excerpt":"\u7d30\u80de\u304c\u5206\u6ccc\u3059\u308b\u7d30\u80de\u5916\u5c0f\u80de\u306e\u4e2d\u3067\u3082\u3001\u30a8\u30af\u30bd\u30bd\u30fc\u30e0\u306f\u305d\u306e\u60c5\u5831\u4f1d\u9054\u6a5f\u80fd\u3084\u75be\u60a3\u3068\u306e\u95a2\u9023\u6027\u304b\u3089\u6ce8\u76ee\u3092\u96c6\u3081\u3066\u3044\u307e\u2026","rel":"","context":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","block_context":{"text":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/mol-bio\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25019_eyecatch.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25019_eyecatch.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25019_eyecatch.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25019_eyecatch.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25019_eyecatch.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25019_eyecatch.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":24382,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/cell-imaging-fluorescent-dye-bid-ts-mbr-25075\/","url_meta":{"origin":499,"position":5},"title":"Cell Painting Assay\u3067\u7528\u3044\u3089\u308c\u308b\u8a66\u85ac\u306b\u3064\u3044\u3066 (Hoechst\u3092\u7528\u3044\u305f\u6838\u67d3\u8272\uff09","author":"LatB Staff","date":"2025\u5e7412\u670810\u65e5","format":false,"excerpt":"\u8fd1\u5e74\u3001\u30bb\u30eb\u30da\u30a4\u30f3\u30c6\u30a3\u30f3\u30b0\uff08Cell Painting\uff09\u3068\u3044\u3046\u30a2\u30c3\u30bb\u30a4\u65b9\u6cd5\u304c\u5e83\u307e\u308a\u3064\u3064\u3042\u308a\u307e\u3059\u3002\u7d30\u80de\u306b\u2026","rel":"","context":"\u7d30\u80de\u57f9\u990a\u30fb\u30a4\u30e1\u30fc\u30b8\u30f3\u30b0","block_context":{"text":"\u7d30\u80de\u57f9\u990a\u30fb\u30a4\u30e1\u30fc\u30b8\u30f3\u30b0","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/cell\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/11\/cell-imaging-fluorescent-dye-bid-ts-mbr-25075_eyecatch-scaled.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/11\/cell-imaging-fluorescent-dye-bid-ts-mbr-25075_eyecatch-scaled.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/11\/cell-imaging-fluorescent-dye-bid-ts-mbr-25075_eyecatch-scaled.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/11\/cell-imaging-fluorescent-dye-bid-ts-mbr-25075_eyecatch-scaled.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/11\/cell-imaging-fluorescent-dye-bid-ts-mbr-25075_eyecatch-scaled.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/11\/cell-imaging-fluorescent-dye-bid-ts-mbr-25075_eyecatch-scaled.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]}],"jetpack_sharing_enabled":true,"amp_enabled":true,"jetpack_featured_media_url":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/cell-morphology-basic-title.jpg","_links":{"self":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/posts\/499","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/users\/988"}],"replies":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/comments?post=499"}],"version-history":[{"count":0,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/posts\/499\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/media\/2806"}],"wp:attachment":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/media?parent=499"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/categories?post=499"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/tags?post=499"},{"taxonomy":"division","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/division?post=499"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}