{"id":509,"date":"2016-11-08T00:00:00","date_gmt":"2016-11-08T00:00:00","guid":{"rendered":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/guidelines-for-maintaining-cultured-cells\/"},"modified":"2025-02-26T16:52:30","modified_gmt":"2025-02-26T07:52:30","slug":"guidelines-for-maintaining-cultured-cells","status":"publish","type":"post","link":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/guidelines-for-maintaining-cultured-cells\/","title":{"rendered":"\u57f9\u990a\u7d30\u80de\u306e\u7d99\u4ee3\u306b\u95a2\u3059\u308b\u77e5\u3063\u3066\u304a\u304f\u3079\u304d\u57fa\u790e\u77e5\u8b58"},"content":{"rendered":"<p><strong>\u7d30\u80de\u57f9\u990a\u306b\u304a\u3051\u308b\u57f9\u990a\u6761\u4ef6\u306f\u3001\u5404\u7d30\u80de\u578b\u306b\u3088\u3063\u3066\u7570\u306a\u308b\u3053\u3068\u306b\u6ce8\u610f\u304c\u5fc5\u8981\u3067\u3059<\/strong>\u3002\u7279\u5b9a\u306e\u7d30\u80de\u578b\u306b\u5fc5\u8981\u3068\u3055\u308c\u308b\u57f9\u990a\u6761\u4ef6\u304b\u3089\u9038\u8131\u3059\u308b\u3053\u3068\u306f\u3001\u7570\u5e38\u306a\u7d30\u80de\u578b\u306e\u767a\u73fe\u304b\u3089\u3001\u7d30\u80de\u57f9\u990a\u306e\u5b8c\u5168\u306a\u5931\u6557\u306b\u81f3\u308b\u69d8\u3005\u306a\u7d50\u679c\u3092\u5f15\u304d\u8d77\u3053\u3059\u53ef\u80fd\u6027\u304c\u3042\u308a\u307e\u3059\u3002\u305d\u306e\u305f\u3081\u3001\u53d6\u308a\u6271\u3046\u7d30\u80de\u7cfb\u306b\u7cbe\u901a\u3057\u3001\u5b9f\u9a13\u306b\u4f7f\u7528\u3059\u308b\u5404\u88fd\u54c1\u4ed8\u5c5e\u306e\u8aac\u660e\u66f8\u306e\u8a18\u8f09\u5185\u5bb9\u306b\u53b3\u5bc6\u306b\u5f93\u308f\u308c\u308b\u3053\u3068\u3092\u63a8\u5968\u3057\u307e\u3059\u3002<\/p>\n<p>\u4eca\u56de\u306f\u3001<strong>\u7d30\u80de\u57f9\u990a\u7cfb\u306b\u304a\u3051\u308b\u57f9\u990a\u7d30\u80de\u306e\u901a\u5e38\u306e\u7d99\u4ee3\u306b\u95a2\u3059\u308b\u3001\u77e5\u3063\u3066\u304a\u304f\u3079\u304d\u57fa\u790e\u77e5\u8b58\u3092\u3054\u7d39\u4ecb\u3057\u307e\u3059\u3002<\/strong><\/p>\n<h2>\u7d99\u4ee3\u3068\u306f?<\/h2>\n<p><strong>\u7d99\u4ee3<\/strong>\u306f\u3001<strong>\u690d\u3048\u7d99\u304e<\/strong>\u3068\u3082\u547c\u3070\u308c\u3001\u57f9\u990a\u7cfb\u304b\u3089\u57f9\u5730\u3092\u9664\u53bb\u3057\u3001\u7d30\u80de\u3092\u65b0\u3057\u3044\u57f9\u5730\u306b\u79fb\u3059\u64cd\u4f5c\u3092\u6307\u3057\u3001\u7d30\u80de\u7cfb\u304a\u3088\u3073\u7d30\u80de\u682a\u304c\u3055\u3089\u306b\u5897\u6b96\u3059\u308b\u3053\u3068\u3092\u53ef\u80fd\u306b\u3059\u308b\u65b9\u6cd5\u3067\u3059\u3002<\/p>\n<p>\u57f9\u990a\u7cfb\u4e2d\u306e\u7d30\u80de\u306e\u6210\u9577\u306f\u3001\u64ad\u7a2e\u306b\u7d9a\u304f<strong>\u8a98\u5c0e\u671f<\/strong>\u304b\u3089\u3001\u7d30\u80de\u304c\u6307\u6570\u95a2\u6570\u7684\u306b\u5897\u6b96\u3059\u308b<strong>\u5bfe\u6570\u5897\u6b96\u671f<\/strong>\u3078\u3068\u9032\u3093\u3067\u884c\u304d\u307e\u3059\u3002\u63a5\u7740\u57f9\u990a\u7cfb\u306e\u7d30\u80de\u304c\u3001\u57f9\u5730\u8868\u9762\u3092\u8986\u3044\u5c3d\u304f\u3057\u3001\u3055\u3089\u306b\u5897\u6b96\u53ef\u80fd\u306a\u5834\u6240\u304c\u5b58\u5728\u3057\u306a\u304f\u306a\u3063\u305f\u6642\u3001\u307e\u305f\u306f\u6d6e\u904a\u57f9\u990a\u7cfb\u306e\u7d30\u80de\u304c\u3055\u3089\u306a\u308b\u6210\u9577\u3092\u652f\u3048\u308b\u57f9\u5730\u306e\u5bb9\u91cf\u3092\u8d85\u3048\u305f\u6642\u3001\u7d30\u80de\u5897\u6b96\u306f\u5927\u304d\u304f\u6e1b\u9000\u3001\u307e\u305f\u306f\u5b8c\u5168\u306b\u505c\u6b62\u3057\u307e\u3059\uff08\u4e0b\u56f3\u3092\u53c2\u7167\u3057\u3066\u304f\u3060\u3055\u3044\uff09\u3002\u7d30\u80de\u3092\u3001\u7d99\u7d9a\u7684\u306b\u6210\u9577\u304c\u884c\u3048\u308b\u6700\u9069\u306a\u5bc6\u5ea6\u306b\u4fdd\u3061\u3001\u305d\u306e\u3055\u3089\u306a\u308b\u5897\u6b96\u3092\u4fc3\u3059\u305f\u3081\u306b\u306f\u3001\u57f9\u990a\u7cfb\u3092\u5206\u5272\u3057\u3001\u65b0\u3057\u3044\u57f9\u5730\u3092\u4f9b\u7d66\u3059\u308b\u3053\u3068\u304c\u5fc5\u8981\u3067\u3059\u3002<\/p>\n<div id=\"attachment_1467\" style=\"width: 873px\" class=\"wp-caption aligncenter\"><a href=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/guidelines-for-maintaining-cultured-cells-fig.png\" rel=\"attachment wp-att-1467\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-1467\" class=\"wp-image-1467 size-full\" src=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/guidelines-for-maintaining-cultured-cells-fig.png\" alt=\"guidelines-for-maintaining-cultured-cells-fig\" width=\"863\" height=\"713\" \/><\/a><p id=\"caption-attachment-1467\" class=\"wp-caption-text\"><strong>\u56f3 \u57f9\u990a\u7d30\u80de\u306b\u7279\u5fb4\u7684\u306a\u5897\u6b96\u66f2\u7dda\u3002<\/strong>\u7d30\u80de\u5bc6\u5ea6\u3068\u57f9\u990a\u65e5\u6570\u306e\u7247\u5bfe\u6570\u30d7\u30ed\u30c3\u30c8\u3067\u8868\u793a\u3057\u3066\u3044\u307e\u3059\u3002\u57f9\u990a\u7d30\u80de\u306f\u3001\u4e00\u822c\u306b\u6a19\u6e96\u7684\u306a\u5897\u6b96\u30d1\u30bf\u30fc\u30f3\u306b\u5f93\u3063\u3066\u5897\u6b96\u3057\u307e\u3059\u3002\u57f9\u990a\u958b\u59cb\u5f8c\u306e\u6700\u521d\u306e\u6210\u9577\u671f\u306f\u8a98\u5c0e\u671f\u3068\u547c\u3070\u308c\u3001\u7d30\u80de\u304c\u57f9\u990a\u6761\u4ef6\u306b\u9806\u5fdc\u3057\u3001\u6d3b\u767a\u306b\u5897\u6b96\u3059\u308b\u305f\u3081\u306e\u6e96\u5099\u3092\u884c\u3046\u6210\u9577\u306e\u9045\u3044\u6642\u671f\u3067\u3059\u3002\u8a98\u5c0e\u671f\u306b\u7d9a\u304f\u5bfe\u6570\u5897\u6b96\u671f\uff08\u3059\u306a\u308f\u3061\u3001\u300c\u5bfe\u6570\u7684\u306a\u300d\u6642\u671f\uff09\u3067\u306f\u3001\u7d30\u80de\u306f\u6307\u6570\u95a2\u6570\u7684\u306b\u5897\u6b96\u3057\u3001\u5897\u6b96\u57f9\u5730\u4e2d\u306e\u6804\u990a\u5206\u3092\u6d88\u8cbb\u3057\u307e\u3059\u3002\u5897\u6b96\u57f9\u5730\u304c\u3059\u3079\u3066\u6d88\u8cbb\u3055\u308c\u308b\uff08\u3059\u306a\u308f\u3061\u30011\u7a2e\u985e\u4ee5\u4e0a\u306e\u6804\u990a\u7d20\u304c\u67af\u6e07\u3059\u308b\uff09\u304b\u3001\u307e\u305f\u306f\u7d30\u80de\u304c\u57f9\u5730\u8868\u9762\u3092\u3059\u3079\u3066\u8986\u3063\u3066\u3057\u307e\u3046\u3068\u3001\u7d30\u80de\u306f\u9759\u6b62\u671f\uff08\u3059\u306a\u308f\u3061\u3001\u5b9a\u5e38\u671f\uff09\u306b\u5165\u308a\u3001\u5897\u6b96\u306f\u5927\u304d\u304f\u6e1b\u9000\u3001\u307e\u305f\u306f\u5b8c\u5168\u306b\u505c\u6b62\u3057\u307e\u3059\u3002<\/p><\/div>\n<h2>\u7d99\u4ee3\u306e\u6642\u671f<\/h2>\n<p>\u7d99\u4ee3\u306e\u5fc5\u8981\u6027\u3092\u6c7a\u5b9a\u3059\u308b\u57fa\u6e96\u306f\u3001\u63a5\u7740\u57f9\u990a\u3068\u6d6e\u904a\u57f9\u990a\u3067\u985e\u4f3c\u3057\u3066\u3044\u307e\u3059\u304c\u3001\u54fa\u4e73\u985e\u7d30\u80de\u3068\u6606\u866b\u7d30\u80de\u3067\u306f\u82e5\u5e72\u306e\u5dee\u304c\u3042\u308a\u307e\u3059\u3002<\/p>\n<h3>\u7d30\u80de\u5bc6\u5ea6<\/h3>\n<h4>\u54fa\u4e73\u985e\u7d30\u80de<\/h4>\n<p>\u63a5\u7740\u6027\u7d30\u80de\u306f\u3001\u30b3\u30f3\u30d5\u30eb\u30a8\u30f3\u30c8\u306b\u9054\u3059\u308b\u524d\u306e\u5bfe\u6570\u5897\u6b96\u671f\u306b\u690d\u3048\u7d99\u304e\u3092\u3059\u308b\u3053\u3068\u304c\u5fc5\u8981\u3067\u3059\u3002\u6b63\u5e38\u306a\u7d30\u80de\u306f\u3001\u30b3\u30f3\u30d5\u30eb\u30a8\u30f3\u30c8\u306b\u9054\u3059\u308b\u3068\u6210\u9577\u3092\u505c\u6b62\u3057\uff08<strong>\u63a5\u89e6\u963b\u5bb3<\/strong>\uff09\u3001\u690d\u3048\u7d99\u304e\u304b\u3089\u56de\u5fa9\u3059\u308b\u306e\u306b\u3088\u308a\u9577\u6642\u9593\u3092\u8981\u3057\u307e\u3059\u3002\u5f62\u8cea\u8ee2\u63db\u3057\u305f\u7d30\u80de\u306f\u3001\u30b3\u30f3\u30d5\u30eb\u30a8\u30f3\u30c8\u306b\u9054\u3057\u305f\u5f8c\u3082\u5897\u6b96\u3092\u7d99\u7d9a\u3059\u308b\u3053\u3068\u304c\u53ef\u80fd\u3067\u3059\u304c\u3001\u4e00\u822c\u306b2\u56de\u306e\u500d\u5316\u5f8c\u3001\u52a3\u5316\u3057\u307e\u3059\u3002\u540c\u69d8\u306b\u3001\u6d6e\u904a\u57f9\u990a\u7d30\u80de\u3082\u3001\u30b3\u30f3\u30d5\u30eb\u30a8\u30f3\u30c8\u306b\u9054\u3059\u308b\u524d\u306e\u5bfe\u6570\u5897\u6b96\u671f\u306b\u690d\u3048\u7d99\u304e\u3092\u3059\u308b\u3053\u3068\u304c\u5fc5\u8981\u3067\u3059\u3002\u6d6e\u904a\u57f9\u990a\u7d30\u80de\u306f\u3001\u30b3\u30f3\u30d5\u30eb\u30a8\u30f3\u30c8\u306b\u9054\u3059\u308b\u3068\u51dd\u96c6\u3057\u3001\u57f9\u990a\u30d5\u30e9\u30b9\u30b3\u3092\u632f\u308a\u6df7\u305c\u308b\u3068\u3001\u57f9\u5730\u304c\u6fc1\u3063\u3066\u898b\u3048\u307e\u3059\u3002<\/p>\n<h4>\u6606\u866b\u7d30\u80de<\/h4>\n<p>\u6606\u866b\u7d30\u80de\u306f\u3001\u30b3\u30f3\u30d5\u30eb\u30a8\u30f3\u30c8\u306b\u9054\u3059\u308b\u524d\u306e\u5bfe\u6570\u5897\u6b96\u671f\u306b\u7d99\u4ee3\u3059\u308b\u3053\u3068\u304c\u5fc5\u8981\u3067\u3059\u3002\u5805\u56fa\u306b\u63a5\u7740\u3057\u305f\u6606\u866b\u7d30\u80de\u306f\u3001\u57f9\u990a\u5bb9\u5668\u304b\u3089\u306e\u5265\u96e2\u304c\u5bb9\u6613\u306b\u306a\u308b\u3001\u30b3\u30f3\u30d5\u30eb\u30a8\u30f3\u30c8\u306b\u9054\u3057\u305f\u72b6\u614b\u3067\u690d\u3048\u7d99\u304e\u3092\u3059\u308b\u3053\u3068\u304c\u53ef\u80fd\u3067\u3059\u304c\u3001\u30b3\u30f3\u30d5\u30eb\u30a8\u30f3\u30c8\u72b6\u614b\u3092\u8d85\u3048\u308b\u5bc6\u5ea6\u3067\u690d\u3048\u7d99\u304e\u3092\u7e70\u308a\u8fd4\u3057\u305f\u7d30\u80de\u3067\u306f\u3001\u500d\u5316\u6642\u9593\u306e\u6e1b\u5c11\u3001\u751f\u5b58\u7387\u306e\u4f4e\u4e0b\u3001\u304a\u3088\u3073\u63a5\u7740\u6027\u306e\u4f4e\u4e0b\u304c\u898b\u3089\u308c\u307e\u3059\u3002\u4e00\u65b9\u3001\u63a5\u7740\u57f9\u990a\u3057\u3066\u3044\u308b\u6606\u866b\u7d30\u80de\u306e\u3001\u30b3\u30f3\u30d5\u30eb\u30a8\u30f3\u30c8\u306b\u9054\u3059\u308b\u524d\u306e\u690d\u3048\u7d99\u304e\u306b\u306f\u3001\u5358\u5c64\u304b\u3089\u7d30\u80de\u3092\u5206\u96e2\u3059\u308b\u305f\u3081\u306b\u3001\u3088\u308a\u5927\u304d\u306a\u6a5f\u68b0\u7684\u529b\u304c\u5fc5\u8981\u3067\u3059\u3002\u30b3\u30f3\u30d5\u30eb\u30a8\u30f3\u30c8\u306b\u9054\u3059\u308b\u524d\u306e\u7d99\u4ee3\u3092\u7e70\u308a\u8fd4\u3059\u3068\u3001\u3053\u308c\u3089\u306e\u7d30\u80de\u3082\u307e\u305f\u3001\u500d\u5316\u6642\u9593\u306e\u6e1b\u5c11\u304a\u3088\u3073\u751f\u5b58\u7387\u306e\u4f4e\u4e0b\u3092\u793a\u3057\u3001\u4e0d\u5065\u5eb7\u3067\u3042\u308b\u3068\u898b\u306a\u3055\u308c\u307e\u3059\u3002<\/p>\n<h3>\u57f9\u5730\u306e\u6804\u990a\u7269\u306e\u67af\u6e07<\/h3>\n<h4>\u54fa\u4e73\u985e\u7d30\u80de<\/h4>\n<p>\u5897\u6b96\u57f9\u5730\u306epH\u306e\u4f4e\u4e0b\u306f\u4e00\u822c\u306b\u3001\u7d30\u80de\u4ee3\u8b1d\u306e\u526f\u7523\u7269\u3067\u3042\u308b\u3001\u4e73\u9178\u306e\u84c4\u7a4d\u3092\u793a\u5506\u3057\u307e\u3059\u3002\u4e73\u9178\u306f\u7d30\u80de\u306b\u3068\u3063\u3066\u6709\u6bd2\u3067\u3042\u308b\u5834\u5408\u3082\u3042\u308a\u3001pH\u306e\u4f4e\u4e0b\u306f\u7d30\u80de\u306e\u6210\u9577\u306b\u3068\u3063\u3066\u6700\u9069\u3067\u306f\u3042\u308a\u307e\u305b\u3093\u3002pH\u306e\u5909\u5316\u306e\u901f\u5ea6\u306f\u4e00\u822c\u306b\u3001\u57f9\u990a\u6db2\u4e2d\u306e\u7d30\u80de\u6fc3\u5ea6\u306b\u4f9d\u5b58\u3057\u3066\u304a\u308a\u3001\u7d30\u80de\u5bc6\u5ea6\u304c\u9ad8\u3044\u5834\u5408\u306b\u306f\u3001\u7d30\u80de\u5bc6\u5ea6\u304c\u4f4e\u3044\u5834\u5408\u3088\u308a\u3082\u57f9\u5730\u306e\u67af\u6e07\u304c\u901f\u304f\u306a\u308a\u307e\u3059\u3002\u7d30\u80de\u5bc6\u5ea6\u304c\u5897\u52a0\u3057\u3001pH\u306e\u6025\u901f\u306a\u4f4e\u4e0b\uff080.1\uff5e0.2\u3092\u8d85\u3048\u308bpH\u306e\u4f4e\u4e0b\uff09\u304c\u898b\u3089\u308c\u308b\u5834\u5408\u306b\u306f\u3001\u7d99\u4ee3\u306e\u5fc5\u8981\u304c\u3042\u308a\u307e\u3059\u3002<\/p>\n<h4>\u6606\u866b\u7d30\u80de<\/h4>\n<p>\u6606\u866b\u7d30\u80de\u306f\u4e00\u822c\u306b\u3001\u54fa\u4e73\u985e\u7d30\u80de\u306b\u4f7f\u7528\u3055\u308c\u308b\u57f9\u5730\u306b\u6bd4\u3079\u3066\u3088\u308a\u9178\u6027\u306e\u5897\u6b96\u57f9\u5730\u3067\u57f9\u990a\u3055\u308c\u307e\u3059\u3002\u4f8b\u3048\u3070\u3001Sf9\u7d30\u80de\u306e\u57f9\u990a\u306b\u4f7f\u7528\u3055\u308c\u308bTNM-FH\u304a\u3088\u3073\u30b0\u30ec\u30fc\u30b9\u57f9\u5730\u306epH\u306f6.2\u3067\u3059\u3002\u54fa\u4e73\u985e\u7d30\u80de\u3068\u306f\u7570\u306a\u308a\u3001\u6606\u866b\u7d30\u80de\u306b\u304a\u3044\u3066\u306f\u3001\u6210\u9577\u306b\u4f34\u3044pH\u306f\u5f90\u3005\u306b\u4e0a\u6607\u3057\u307e\u3059\u304c\u3001\u4e00\u822c\u306bpH6.4\u3092\u8d85\u3048\u308b\u3053\u3068\u306f\u3042\u308a\u307e\u305b\u3093\u3002\u3057\u304b\u3057\u3001\u54fa\u4e73\u985e\u7d30\u80de\u3068\u540c\u69d8\u306b\u3001\u6606\u866b\u7d30\u80de\u3082\u5bc6\u5ea6\u304c\u4e0a\u6607\u3059\u308b\u3068\u5897\u6b96\u57f9\u5730\u306epH\u306f\u4f4e\u4e0b\u3057\u59cb\u3081\u307e\u3059\u3002<\/p>\n<h3>\u7d99\u4ee3\u306e\u30b9\u30b1\u30b8\u30e5\u30fc\u30eb<\/h3>\n<p>\u53b3\u5bc6\u306a\u30b9\u30b1\u30b8\u30e5\u30fc\u30eb\u306b\u5f93\u3063\u3066\u7d30\u80de\u306e\u690d\u3048\u7d99\u304e\u3092\u884c\u3046\u3053\u3068\u3067\u3001\u7d30\u80de\u306e\u6027\u8cea\u306e\u518d\u73fe\u6027\u304c\u4fdd\u8a3c\u3055\u308c\u3001\u305d\u306e\u5065\u5eb7\u72b6\u614b\u3092\u76e3\u8996\u3059\u308b\u3053\u3068\u304c\u53ef\u80fd\u3067\u3059\u3002\u3054\u4f7f\u7528\u306b\u306a\u308b\u7d30\u80de\u306e\u64ad\u7a2e\u5bc6\u5ea6\u3092\u3001\u5f53\u8a72\u7d30\u80de\u306b\u9069\u5207\u306a\u6210\u9577\u901f\u5ea6\u304a\u3088\u3073\u53ce\u7387\u304c\u5f97\u3089\u308c\u308b\u307e\u3067\u3001\u4e00\u5b9a\u306e\u5024\u304b\u3089\u5909\u5316\u3055\u305b\u3066\u304f\u3060\u3055\u3044\u3002\u6210\u9577\u30d1\u30bf\u30fc\u30f3\u304b\u3089\u306e\u9038\u8131\u306f\u3001\u57f9\u990a\u7d30\u80de\u304c\u4e0d\u5065\u5eb7\u3067\u3042\u308b\uff08\u4f8b\uff1a \u52a3\u5316\u304a\u3088\u3073\u6c5a\u67d3\uff09\u3001\u307e\u305f\u306f\u7d30\u80de\u57f9\u990a\u7cfb\u306e\u6210\u5206\u304c\u6b63\u3057\u304f\u6a5f\u80fd\u3057\u3066\u3044\u306a\u3044\uff08\u4f8b\uff1a\u6e29\u5ea6\u304c\u6700\u9069\u3067\u306a\u3044\u3001\u307e\u305f\u306f\u57f9\u5730\u304c\u53e4\u3059\u304e\u308b\uff09\u3053\u3068\u3092\u793a\u5506\u3057\u3066\u3044\u307e\u3059\u3002\u8a73\u7d30\u306a\u7d30\u80de\u57f9\u990a\u8a18\u9332\u3092\u4f5c\u6210\u3057\u3001\u88dc\u7d66\u304a\u3088\u3073\u7d99\u4ee3\u306e\u30b9\u30b1\u30b8\u30e5\u30fc\u30eb\u3001\u4f7f\u7528\u3057\u305f\u57f9\u5730\u306e\u7a2e\u985e\u3001\u5206\u96e2\u6cd5\u3001\u5206\u96e2\u6bd4\u3001\u5f62\u614b\u5b66\u7684\u89b3\u5bdf\u7d50\u679c\u3001\u64ad\u7a2e\u6fc3\u5ea6\u3001\u53ce\u7387\u304a\u3088\u3073\u6297\u751f\u7269\u8cea\u306e\u4f7f\u7528\u3092\u8a18\u9332\u3055\u308c\u308b\u3053\u3068\u3092\u5f37\u304f\u63a8\u5968\u3057\u307e\u3059\u3002<\/p>\n<p>\u5b9f\u9a13\u304a\u3088\u3073\u7279\u5225\u306a\u64cd\u4f5c\uff08\u4f8b\uff1a \u57f9\u5730\u306e\u7a2e\u985e\u306e\u5909\u66f4\uff09\u306f\u3001\u7d99\u4ee3\u306e\u30b9\u30b1\u30b8\u30e5\u30fc\u30eb\u306b\u5408\u308f\u305b\u3066\u884c\u3046\u306e\u304c\u6700\u3082\u7406\u60f3\u7684\u3067\u3059\u3002\u5b9f\u9a13\u8a08\u753b\u304c\u3001\u78ba\u7acb\u3055\u308c\u305f\u7d99\u4ee3\u306e\u30b9\u30b1\u30b8\u30e5\u30fc\u30eb\u306b\u5408\u81f4\u3057\u306a\u3044\u5834\u5408\u3001\u7d30\u80de\u304c\u8a98\u5c0e\u671f\u306b\u3042\u308b\u9593\u3001\u307e\u305f\u306f\u30b3\u30f3\u30d5\u30eb\u30a8\u30f3\u30c8\u306b\u9054\u3057\u3066\u5897\u6b96\u304c\u505c\u6b62\u3057\u3066\u3044\u308b\u6642\u306b\u306f\u3001\u6c7a\u3057\u3066\u690d\u3048\u7d99\u304e\u3092\u884c\u308f\u306a\u3044\u3088\u3046\u306b\u6ce8\u610f\u3057\u3066\u304f\u3060\u3055\u3044\u3002<\/p>\n<h2>\u4e00\u822c\u7684\u306a\u7d30\u80de\u7cfb\u306b\u63a8\u5968\u3055\u308c\u308b\u57f9\u5730<\/h2>\n<p>\u4e0d\u6b7b\u5316\u54fa\u4e73\u985e\u7d30\u80de\u7cfb\u306f\u3001\u8840\u6e05\u3092\u6dfb\u52a0\u3057\u305f<a href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/life-science\/cell-culture\/mammalian-cell-culture\/cell-culture-media\/mem.html?CID=bid_clb_cce_r04_jp_cp0000_pjt0000_bid00000_0so_blg_op_awa_oc_s00_cc7_Social_LAB\" target=\"_blank\" rel=\"noopener noreferrer\">MEM<\/a>\u306a\u3069\u306e\u6bd4\u8f03\u7684\u5358\u7d14\u306a\u57f9\u5730\u4e0a\u3067\u7dad\u6301\u3059\u308b\u3053\u3068\u304c\u53ef\u80fd\u3067\u3001\u307e\u305fMEM\u4e2d\u3067\u57f9\u990a\u3055\u308c\u305f\u7d30\u80de\u306f\u3001\u304a\u305d\u3089\u304f<a href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/life-science\/cell-culture\/mammalian-cell-culture\/cell-culture-media\/dmem.html?CID=bid_clb_cce_r04_jp_cp0000_pjt0000_bid00000_0so_blg_op_awa_oc_s00_cc7_Social_LAB\" target=\"_blank\" rel=\"noopener noreferrer\">DMEM<\/a>\u304a\u3088\u3073<a href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/life-science\/cell-culture\/mammalian-cell-culture\/cell-culture-media.html?CID=bid_clb_cce_r04_jp_cp0000_pjt0000_bid00000_0so_blg_op_awa_oc_s00_cc7_Social_LAB\" target=\"_blank\" rel=\"noopener noreferrer\">Medium 199\u57f9\u5730<\/a>\u306b\u304a\u3044\u3066\u3082\u3001\u540c\u69d8\u306b\u5bb9\u6613\u306b\u57f9\u990a\u3059\u308b\u3053\u3068\u304c\u53ef\u80fd\u3067\u3042\u308b\u3068\u8003\u3048\u3089\u308c\u307e\u3059\u3002\u3057\u304b\u3057\u3001\u7279\u5225\u306a\u6a5f\u80fd\u304c\u767a\u73fe\u3055\u308c\u3066\u3044\u308b\u5834\u5408\u306b\u306f\u3001\u3088\u308a\u8907\u96d1\u306a\u57f9\u5730\u304c\u5fc5\u8981\u306b\u306a\u308b\u53ef\u80fd\u6027\u304c\u3042\u308a\u307e\u3059\u3002\u7279\u5b9a\u306e\u7d30\u80de\u306b\u5bfe\u3057\u3066\u9069\u5207\u306a\u57f9\u5730\u3092\u9078\u629e\u3059\u308b\u305f\u3081\u306e\u60c5\u5831\u306f\u3001\u4e00\u822c\u306b\u6587\u732e\u304b\u3089\u5165\u624b\u53ef\u80fd\u3067\u3042\u308a\u3001\u7d30\u80de\u306e\u4f9b\u7d66\u8005\u307e\u305f\u306f\u7d30\u80de\u30d0\u30f3\u30af\u304b\u3089\u3082\u5165\u624b\u53ef\u80fd\u306a\u5834\u5408\u304c\u3042\u308a\u307e\u3059\u3002<\/p>\n<p>\u3054\u4f7f\u7528\u306e\u7d30\u80de\u578b\u306b\u95a2\u3059\u308b\u60c5\u5831\u304c\u5165\u624b\u4e0d\u53ef\u80fd\u306a\u5834\u5408\u3001\u5897\u6b96\u57f9\u5730\u304a\u3088\u3073\u8840\u6e05\u3092\u7d4c\u9a13\u306b\u57fa\u3065\u3044\u3066\u9078\u629e\u3059\u308b\u304b\u3001\u307e\u305f\u306f\u6570\u7a2e\u985e\u306e\u7570\u306a\u308b\u57f9\u5730\u3092\u8a66\u9a13\u3057\u3066\u3001\u6700\u9069\u306a\u7d50\u679c\u306e\u5f97\u3089\u308c\u308b\u57f9\u5730\u3092\u898b\u3064\u3051\u51fa\u3057\u3066\u304f\u3060\u3055\u3044\u3002\u4e00\u822c\u7684\u306b\u306f\u3001\u63a5\u7740\u7d30\u80de\u306b\u306f<a href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/life-science\/cell-culture\/mammalian-cell-culture\/cell-culture-media\/mem.html?CID=bid_clb_cce_r04_jp_cp0000_pjt0000_bid00000_0so_blg_op_awa_oc_s00_cc7_Social_LAB\" target=\"_blank\" rel=\"noopener noreferrer\">MEM<\/a>\u3001\u6d6e\u904a\u7d30\u80de\u306b\u306f<a href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/life-science\/cell-culture\/mammalian-cell-culture\/cell-culture-media\/rpmi.html?CID=bid_clb_cce_r04_jp_cp0000_pjt0000_bid00000_0so_blg_op_awa_oc_s00_cc7_Social_LAB\" target=\"_blank\" rel=\"noopener noreferrer\">RPMI-1640<\/a>\u304c\u3001\u57f9\u5730\u691c\u8a0e\u306e\u826f\u597d\u306a\u51fa\u767a\u70b9\u3068\u3057\u3066\u4f7f\u7528\u3067\u304d\u307e\u3059\u3002\u4e0b\u8868\u306e\u6761\u4ef6\u306f\u3001\u65b0\u3057\u3044\u54fa\u4e73\u985e\u7d30\u80de\u57f9\u990a\u3092\u30bb\u30c3\u30c8\u30a2\u30c3\u30d7\u3059\u308b\u969b\u306e\u30ac\u30a4\u30c9\u30e9\u30a4\u30f3\u3068\u3057\u3066\u3054\u4f7f\u7528\u3044\u305f\u3060\u3051\u307e\u3059\u3002<\/p>\n<p>\u6606\u866b\u7d30\u80de\u306f\u3001\u54fa\u4e73\u985e\u7d30\u80de\u306b\u4f7f\u7528\u3055\u308c\u308b\u5897\u6b96\u57f9\u5730\u3088\u308a\u3082\u4e00\u822c\u306b\u3088\u308a\u9178\u6027\u5ea6\u306e\u9ad8\u3044\u5897\u6b96\u57f9\u5730\u3067\u3042\u308b\u3001TNM-FH\u304a\u3088\u3073\u30b0\u30ec\u30fc\u30b9\u57f9\u5730\u306a\u3069\u7528\u3044\u3066\u57f9\u990a\u3055\u308c\u307e\u3059\u3002<\/p>\n<table>\n<caption>\u88681 \u54fa\u4e73\u985e\u57f9\u990a\u7d30\u80de\u306b\u9069\u3057\u305f\u57f9\u5730\u307e\u3068\u3081<\/caption>\n<tbody>\n<tr>\n<th style=\"text-align: center\" colspan=\"5\"><strong>\u54fa\u4e73\u985e\u57f9\u990a\u7d30\u80de<\/strong><\/th>\n<\/tr>\n<tr>\n<th><strong>\u7d30\u80de\u7cfb<\/strong><\/th>\n<th><strong>\u7d30\u80de\u578b<\/strong><\/th>\n<th><strong>\u7a2e<\/strong><\/th>\n<th><strong>\u7d44\u7e54<\/strong><\/th>\n<th><strong>\u57f9\u5730<sup>\u203b<\/sup><\/strong><\/th>\n<\/tr>\n<tr>\n<td>293<\/td>\n<td>\u7dda\u7dad\u82bd\u7d30\u80de<\/td>\n<td>\u30d2\u30c8<\/td>\n<td>\u80da\u814e\u81d3<\/td>\n<td>MEM\u304a\u3088\u307310% FBS<\/td>\n<\/tr>\n<tr>\n<td>3T6<\/td>\n<td>\u7dda\u7dad\u82bd\u7d30\u80de<\/td>\n<td>\u30de\u30a6\u30b9<\/td>\n<td>\u80da<\/td>\n<td>DMEM\u304a\u3088\u307310% FBS<\/td>\n<\/tr>\n<tr>\n<td>A549<\/td>\n<td>\u4e0a\u76ae\u6027\u7d30\u80de<\/td>\n<td>\u30d2\u30c8<\/td>\n<td>\u80ba\u764c<\/td>\n<td>F-12K\u304a\u3088\u307310% FBS<\/td>\n<\/tr>\n<tr>\n<td>A9<\/td>\n<td>\u7dda\u7dad\u82bd\u7d30\u80de<\/td>\n<td>\u30de\u30a6\u30b9<\/td>\n<td>\u7d50\u5408\u7d44\u7e54<\/td>\n<td>DMEM\u304a\u3088\u307310% FBS<\/td>\n<\/tr>\n<tr>\n<td>AtT-20<\/td>\n<td>\u4e0a\u76ae\u6027\u7d30\u80de<\/td>\n<td>\u30de\u30a6\u30b9<\/td>\n<td>\u4e0b\u5782\u4f53\u816b\u760d<\/td>\n<td>F-10, 15% \u30a6\u30de\u8840\u6e05\u304a\u3088\u30732.5% FBS<\/td>\n<\/tr>\n<tr>\n<td>BALB\/3T3<\/td>\n<td>\u7dda\u7dad\u82bd\u7d30\u80de<\/td>\n<td>\u30de\u30a6\u30b9<\/td>\n<td>\u80da<\/td>\n<td>DMEM\u304a\u3088\u307310% FBS<\/td>\n<\/tr>\n<tr>\n<td>BHK-21<\/td>\n<td>\u7dda\u7dad\u82bd\u7d30\u80de<\/td>\n<td>\u30cf\u30e0\u30b9\u30bf\u30fc<\/td>\n<td>\u814e\u81d3<\/td>\n<td>GMEM\u304a\u3088\u307310% FBS\u307e\u305f\u306fMEM\u300110% FBS\u304a\u3088\u3073NEAA<\/td>\n<\/tr>\n<tr>\n<td>BHL-100<\/td>\n<td>\u4e0a\u76ae\u6027\u7d30\u80de<\/td>\n<td>\u30d2\u30c8<\/td>\n<td>\u4e73\u623f<\/td>\n<td>McCoy&#8217;s 5A\u304a\u3088\u307310% FBS<\/td>\n<\/tr>\n<tr>\n<td>BT<\/td>\n<td>\u7dda\u7dad\u82bd\u7d30\u80de<\/td>\n<td>\u30a6\u30b7<\/td>\n<td>\u9f3b\u7532\u4ecb\u7d30\u80de<\/td>\n<td>MEM\u300110% FBS\u304a\u3088\u3073NEAA<\/td>\n<\/tr>\n<tr>\n<td>Caco-2<\/td>\n<td>\u4e0a\u76ae\u6027\u7d30\u80de<\/td>\n<td>\u30d2\u30c8<\/td>\n<td>\u5927\u8178\u817a\u764c<\/td>\n<td>MEM\u300120% FBS\u304a\u3088\u3073NEAA<\/td>\n<\/tr>\n<tr>\n<td>Chang<\/td>\n<td>\u4e0a\u76ae\u6027\u7d30\u80de<\/td>\n<td>\u30d2\u30c8<\/td>\n<td>\u809d\u81d3<\/td>\n<td>BME\u304a\u3088\u307310% \u4ed4\u30a6\u30b7\u8840\u6e05<\/td>\n<\/tr>\n<tr>\n<td>CHO-K1<\/td>\n<td>\u4e0a\u76ae\u6027\u7d30\u80de<\/td>\n<td>\u30cf\u30e0\u30b9\u30bf\u30fc<\/td>\n<td>\u5375\u5de3<\/td>\n<td>F-12\u304a\u3088\u307310% FBS<\/td>\n<\/tr>\n<tr>\n<td>Clone 9<\/td>\n<td>\u4e0a\u76ae\u6027\u7d30\u80de<\/td>\n<td>\u30e9\u30c3\u30c8<\/td>\n<td>\u809d\u81d3<\/td>\n<td>F-12K\u304a\u3088\u307310% FBS<\/td>\n<\/tr>\n<tr>\n<td>Clone M-3<\/td>\n<td>\u4e0a\u76ae\u6027\u7d30\u80de<\/td>\n<td>\u30de\u30a6\u30b9<\/td>\n<td>\u30e1\u30e9\u30ce\u30fc\u30de<\/td>\n<td>F-10, 15% \u30a6\u30de\u8840\u6e05\u304a\u3088\u30732.5% FBS<\/td>\n<\/tr>\n<tr>\n<td>COS-1, COS-3, COS-7<\/td>\n<td>\u7dda\u7dad\u82bd\u7d30\u80de<\/td>\n<td>\u30b5\u30eb<\/td>\n<td>\u814e\u81d3<\/td>\n<td>DMEM\u304a\u3088\u307310% FBS<\/td>\n<\/tr>\n<tr>\n<td>CRFK<\/td>\n<td>\u4e0a\u76ae\u6027\u7d30\u80de<\/td>\n<td>\u30cd\u30b3<\/td>\n<td>\u814e\u81d3<\/td>\n<td>MEM\u300110% FBS\u304a\u3088\u3073NEAA<\/td>\n<\/tr>\n<tr>\n<td>CV-1<\/td>\n<td>\u7dda\u7dad\u82bd\u7d30\u80de<\/td>\n<td>\u30b5\u30eb<\/td>\n<td>\u814e\u81d3<\/td>\n<td>MEM\u304a\u3088\u307310% FBS<\/td>\n<\/tr>\n<tr>\n<td>D-17<\/td>\n<td>\u4e0a\u76ae\u6027\u7d30\u80de<\/td>\n<td>\u30a4\u30cc<\/td>\n<td>\u9aa8\u8089\u816b<\/td>\n<td>MEM\u300110% FBS\u304a\u3088\u3073NEAA<\/td>\n<\/tr>\n<tr>\n<td>Daudi<\/td>\n<td>\u30ea\u30f3\u30d1\u82bd\u7403\u7d30\u80de<\/td>\n<td>\u30d2\u30c8<\/td>\n<td>\u30ea\u30f3\u30d1\u816b\u60a3\u8005\u306e\u8840\u6db2<\/td>\n<td>RPMI-1640\u304a\u3088\u307310% FBS<\/td>\n<\/tr>\n<tr>\n<td>GH1, GH3<\/td>\n<td>\u4e0a\u76ae\u6027\u7d30\u80de<\/td>\n<td>\u30e9\u30c3\u30c8<\/td>\n<td>\u4e0b\u5782\u4f53\u816b\u760d<\/td>\n<td>F-10, 15% \u30a6\u30de\u8840\u6e05\u304a\u3088\u30732.5% FBS<\/td>\n<\/tr>\n<tr>\n<td>H9<\/td>\n<td>\u30ea\u30f3\u30d1\u82bd\u7403\u7d30\u80de<\/td>\n<td>\u30d2\u30c8<\/td>\n<td>T\u7d30\u80de\u30ea\u30f3\u30d1\u816b<\/td>\n<td>RPMI-1640\u304a\u3088\u307320% FBS<\/td>\n<\/tr>\n<tr>\n<td>HaK<\/td>\n<td>\u4e0a\u76ae\u6027\u7d30\u80de<\/td>\n<td>\u30cf\u30e0\u30b9\u30bf\u30fc<\/td>\n<td>\u814e\u81d3<\/td>\n<td>BME\u304a\u3088\u307310% \u4ed4\u30a6\u30b7\u8840\u6e05<\/td>\n<\/tr>\n<tr>\n<td>HCT-15<\/td>\n<td>\u4e0a\u76ae\u6027\u7d30\u80de<\/td>\n<td>\u30d2\u30c8<\/td>\n<td>\u7d50\u8178\u76f4\u8178\u817a\u764c<\/td>\n<td>RPMI-1640\u304a\u3088\u307310% FBS<\/td>\n<\/tr>\n<tr>\n<td>HeLa<\/td>\n<td>\u4e0a\u76ae\u6027\u7d30\u80de<\/td>\n<td>\u30d2\u30c8<\/td>\n<td>\u5b50\u5bae\u9838\u764c<\/td>\n<td>MEM\u300110% FBS\u304a\u3088\u3073NEAA (S-MEM\u61f8\u6fc1)<\/td>\n<\/tr>\n<tr>\n<td>HEp-2<\/td>\n<td>\u4e0a\u76ae\u6027\u7d30\u80de<\/td>\n<td>\u30d2\u30c8<\/td>\n<td>\u5589\u982d\u764c<\/td>\n<td>MEM\u304a\u3088\u307310% FBS<\/td>\n<\/tr>\n<tr>\n<td>HL-60<\/td>\n<td>\u30ea\u30f3\u30d1\u82bd\u7403\u7d30\u80de<\/td>\n<td>\u30d2\u30c8<\/td>\n<td>\u524d\u9aa8\u9ac4\u7403\u6027\u767d\u8840\u75c5<\/td>\n<td>RPMI-1640\u304a\u3088\u307320% FBS<\/td>\n<\/tr>\n<tr>\n<td>HT-1080<\/td>\n<td>\u4e0a\u76ae\u6027\u7d30\u80de<\/td>\n<td>\u30d2\u30c8<\/td>\n<td>\u7dda\u7dad\u8089\u816b<\/td>\n<td>MEM\u304a\u3088\u307310% HI FBS\u304a\u3088\u3073NEAA<\/td>\n<\/tr>\n<tr>\n<td>HT-29<\/td>\n<td>\u4e0a\u76ae\u6027\u7d30\u80de<\/td>\n<td>\u30d2\u30c8<\/td>\n<td>\u5927\u8178\u817a\u764c<\/td>\n<td>McCoy&#8217;s 5A\u304a\u3088\u307310% FBS<\/td>\n<\/tr>\n<tr>\n<td>HUVEC<\/td>\n<td>\u5185\u76ae\u6027\u7d30\u80de<\/td>\n<td>\u30d2\u30c8<\/td>\n<td>\u81cd\u5e2f<\/td>\n<td>F-12K\u304a\u3088\u307310% FBS\u304a\u3088\u3073100 \u00b5g\/mL \u30d8\u30d1\u30ea\u30f3<\/td>\n<\/tr>\n<tr>\n<td>I-10<\/td>\n<td>\u4e0a\u76ae\u6027\u7d30\u80de<\/td>\n<td>\u30de\u30a6\u30b9<\/td>\n<td>\u7cbe\u5de3\u816b\u760d<\/td>\n<td>F-10, 15% \u30a6\u30de\u8840\u6e05\u304a\u3088\u30732.5% FBS<\/td>\n<\/tr>\n<tr>\n<td>IM-9<\/td>\n<td>\u30ea\u30f3\u30d1\u82bd\u7403\u7d30\u80de<\/td>\n<td>\u30d2\u30c8<\/td>\n<td>\u9aa8\u9ac4\u816b\u60a3\u8005\u306e\u9aa8\u9ac4<\/td>\n<td>RPMI-1640\u304a\u3088\u307310% FBS<\/td>\n<\/tr>\n<tr>\n<td>JEG-2<\/td>\n<td>\u4e0a\u76ae\u6027\u7d30\u80de<\/td>\n<td>\u30d2\u30c8<\/td>\n<td>\u7d68\u6bdb\u764c<\/td>\n<td>MEM\u304a\u3088\u307310% FBS<\/td>\n<\/tr>\n<tr>\n<td>Jensen<\/td>\n<td>\u7dda\u7dad\u82bd\u7d30\u80de<\/td>\n<td>\u30e9\u30c3\u30c8<\/td>\n<td>\u8089\u816b<\/td>\n<td>McCoy&#8217;s 5A\u304a\u3088\u30735% FBS<\/td>\n<\/tr>\n<tr>\n<td>Jurkat<\/td>\n<td>\u30ea\u30f3\u30d1\u82bd\u7403\u7d30\u80de<\/td>\n<td>\u30d2\u30c8<\/td>\n<td>\u30ea\u30f3\u30d1\u816b<\/td>\n<td>RPMI-1640\u304a\u3088\u307310% FBS<\/td>\n<\/tr>\n<tr>\n<td>K-562<\/td>\n<td>\u30ea\u30f3\u30d1\u82bd\u7403\u7d30\u80de<\/td>\n<td>\u30d2\u30c8<\/td>\n<td>\u9aa8\u9ac4\u6027\u767d\u8840\u75c5<\/td>\n<td>RPMI-1640\u304a\u3088\u307310% FBS<\/td>\n<\/tr>\n<tr>\n<td>KB<\/td>\n<td>\u4e0a\u76ae\u6027\u7d30\u80de<\/td>\n<td>\u30d2\u30c8<\/td>\n<td>\u53e3\u8154\u764c<\/td>\n<td>MEM\u304a\u3088\u307310% FBS\u304a\u3088\u3073NEAA<\/td>\n<\/tr>\n<tr>\n<td>KG-1<\/td>\n<td>\u9aa8\u9ac4\u82bd\u7403\u7d30\u80de<\/td>\n<td>\u30d2\u30c8<\/td>\n<td>\u8d64\u767d\u8840\u75c5\u60a3\u8005\u306e\u9aa8\u9ac4<\/td>\n<td>IMDM\u304a\u3088\u307320% FBS<\/td>\n<\/tr>\n<tr>\n<td>L2<\/td>\n<td>\u4e0a\u76ae\u6027\u7d30\u80de<\/td>\n<td>\u30e9\u30c3\u30c8<\/td>\n<td>\u80ba<\/td>\n<td>F-12K\u304a\u3088\u307310% FBS<\/td>\n<\/tr>\n<tr>\n<td>LLC-WRC 256<\/td>\n<td>\u4e0a\u76ae\u6027\u7d30\u80de<\/td>\n<td>\u30e9\u30c3\u30c8<\/td>\n<td>\u764c<\/td>\n<td>Medium 199\u304a\u3088\u30735% \u30a6\u30de\u8840\u6e05<\/td>\n<\/tr>\n<tr>\n<td>McCoy<\/td>\n<td>\u7dda\u7dad\u82bd\u7d30\u80de<\/td>\n<td>\u30de\u30a6\u30b9<\/td>\n<td>\u672a\u77e5<\/td>\n<td>MEM\u304a\u3088\u307310% FBS<\/td>\n<\/tr>\n<tr>\n<td>MCF7<\/td>\n<td>\u4e0a\u76ae\u6027\u7d30\u80de<\/td>\n<td>\u30d2\u30c8<\/td>\n<td>\u4e73\u817a\u764c<\/td>\n<td>MEM\u304a\u3088\u307310% FBS\u304a\u3088\u3073NEAA\u304a\u3088\u307310 \u00b5g\/mL \u30a4\u30f3\u30b7\u30e5\u30ea\u30f3<\/td>\n<\/tr>\n<tr>\n<td>WI-38<\/td>\n<td>\u4e0a\u76ae\u6027\u7d30\u80de<\/td>\n<td>\u30d2\u30c8<\/td>\n<td>\u80ce\u5150\u80ba<\/td>\n<td>BME\u304a\u3088\u307310% FBS<\/td>\n<\/tr>\n<tr>\n<td>WISH<\/td>\n<td>\u4e0a\u76ae\u6027\u7d30\u80de<\/td>\n<td>\u30d2\u30c8<\/td>\n<td>\u7f8a\u819c<\/td>\n<td>BME\u304a\u3088\u307310% FBS<\/td>\n<\/tr>\n<tr>\n<td>XC<\/td>\n<td>\u4e0a\u76ae\u6027\u7d30\u80de<\/td>\n<td>\u30e9\u30c3\u30c8<\/td>\n<td>\u8089\u816b<\/td>\n<td>MEM\u304a\u3088\u307310% FBS\u304a\u3088\u3073NEAA<\/td>\n<\/tr>\n<tr>\n<td>Y-1<\/td>\n<td>\u4e0a\u76ae\u6027\u7d30\u80de<\/td>\n<td>\u30de\u30a6\u30b9<\/td>\n<td>\u526f\u814e\u816b\u760d<\/td>\n<td>F-10, 15% \u30a6\u30de\u8840\u6e05\u304a\u3088\u30732.5% FBS<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table>\n<caption>\u88682 \u6606\u866b\u57f9\u990a\u7d30\u80de\u306b\u9069\u3057\u305f\u57f9\u5730\u307e\u3068\u3081<\/caption>\n<tbody>\n<tr>\n<th style=\"text-align: center\" colspan=\"4\"><strong>\u6606\u866b\u7d30\u80de\u57f9\u990a<\/strong><\/th>\n<\/tr>\n<tr>\n<th><strong>\u7d30\u80de\u7cfb<\/strong><\/th>\n<th><strong>\u7a2e<\/strong><\/th>\n<th><strong>\u7d44\u7e54<\/strong><\/th>\n<th><strong>\u57f9\u5730<sup>\u203b<\/sup><\/strong><\/th>\n<\/tr>\n<tr>\n<td>Sf9, Sf21<\/td>\n<td>\u30c4\u30de\u30b8\u30ed\u30af\u30b5\u30e8\u30c8\u30a6<br \/>\n(<i>Spodoptera frugiperda<\/i>)<\/td>\n<td>\u86f9\u306e\u5375\u5de3<\/td>\n<td>TNM-FH\u304a\u3088\u307310% FBS\u307e\u305f\u306fSf-900 II SFM (\u7121\u8840\u6e05)\u307e\u305f\u306fSf-900\u2122 III SFM (\u7121\u8840\u6e05)<\/td>\n<\/tr>\n<tr>\n<td>High Five\u2122 (BTI-TN-5B1-4)<\/td>\n<td>\u30ad\u30e3\u30d9\u30c4\u30b7\u30e3\u30af\u30c8\u30ea\u30e0\u30b7<br \/>\n(<i>Trichoplusia ni<\/i>)<\/td>\n<td>\u5375\u5de3<\/td>\n<td>TNM-FH\u304a\u3088\u307310% FBS\u307e\u305f\u306fExpress Five\u00ae SFM (\u7121\u8840\u6e05)<\/td>\n<\/tr>\n<tr>\n<td>Schneider 2 (S2), D.Mel-2<\/td>\n<td>\u30b7\u30e7\u30a6\u30b8\u30e7\u30a6\u30d0\u30a8<br \/>\n(<i>Drosophila melanogaster<\/i>)<\/td>\n<td><\/td>\n<td>\u30b7\u30e5\u30ca\u30a4\u30c0\u30fc\u30b7\u30e7\u30a6\u30b8\u30e7\u30a6\u30d0\u30a8\u57f9\u5730\u304a\u3088\u307310%\u975e\u50cd\u5316FBS<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><span style=\"font-size: 8pt\">\u203b<strong>BME<\/strong>\uff1a Basal Medium Eagle\uff08\u30a4\u30fc\u30b0\u30eb\u57fa\u790e\u57f9\u5730\uff09\u3001<strong>DMEM<\/strong>\uff1a Dulbecco&#8217;s Modified Eagle Medium\uff08\u30c0\u30eb\u30d9\u30c3\u30b3\u5909\u6cd5\u30a4\u30fc\u30b0\u30eb\u57f9\u5730\uff09\u3001<strong>FBS<\/strong>\uff1a Fetal Bovine Serum\uff08\u30a6\u30b7\u80ce\u5150\u8840\u6e05\uff09\u3001<strong>GMEM<\/strong>\uff1a Glasgow Minimum Essential Medium\uff08\u30b0\u30e9\u30b9\u30b4\u30fc\u6700\u5c0f\u5fc5\u9808\u57f9\u5730\uff09\u3001<strong>IMDM<\/strong>\uff1a Iscove&#8217;s Modified Dulbecco&#8217;s Medium\uff08\u30a4\u30b9\u30b3\u30d5\u6539\u5909\u30c0\u30eb\u30d9\u30c3\u30b3\u57f9\u5730\uff09\u3001<strong>MEM<\/strong>\uff1a Minimum <\/span><span style=\"font-size: 8pt\">Essential Medium\uff08\u6700\u5c0f\u5fc5\u9808\u57f9\u5730\uff09\u3001<strong>NEAA<\/strong>\uff1a Non-Essential Amino Acids Solution\uff08\u975e\u5fc5\u9808\u30a2\u30df\u30ce\u9178\u6eb6\u6db2\uff09\u3001<strong>TNM-FH<\/strong>\uff1a Trichoplusia ni Medium-Formulation Hink\uff08\u30b5\u30d7\u30ea\u30e1\u30f3\u30c8\u3092\u6dfb\u52a0\u3057\u305f\u30b0\u30ec\u30fc\u30b9\u6606\u866b\u57f9\u5730\uff09<\/span><\/p>\n<h2>\u63a5\u7740\u7d30\u80de\u306e\u89e3\u96e2<\/h2>\n<p>\u63a5\u7740\u7d30\u80de\u306e\u7d99\u4ee3\u306e\u7b2c1\u6bb5\u968e\u306f\u3001\u7d30\u80de\u3092\u57f9\u990a\u5bb9\u5668\u304b\u3089\u3001\u9175\u7d20\u307e\u305f\u306f\u6a5f\u68b0\u7684\u306a\u65b9\u6cd5\u3067\u5265\u96e2\u3059\u308b\u3053\u3068\u3067\u3059\u3002\u69d8\u3005\u306a\u7d30\u80de\u89e3\u96e2\u306e\u65b9\u6cd5\u3092\u4e0b\u8868\u306b\u793a\u3057\u307e\u3059\u3002<\/p>\n<table>\n<caption>\u88683 \u69d8\u3005\u306a\u7d30\u80de\u89e3\u96e2\u306e\u65b9\u6cd5<\/caption>\n<tbody>\n<tr>\n<td style=\"text-align: center\"><strong>\u65b9\u6cd5<\/strong><\/td>\n<td style=\"text-align: center\"><strong>\u89e3\u96e2\u5264<\/strong><\/td>\n<td style=\"text-align: center\"><strong>\u9069\u5fdc\u5bfe\u8c61<\/strong><\/td>\n<\/tr>\n<tr>\n<td>\u632f\u308a\u843d\u3068\u3057<\/td>\n<td>\u57f9\u990a\u5bb9\u5668\u306e\u7a4f\u3084\u304b\u306a\u632f\u308a\u6df7\u305c\u3001\u307e\u305f\u306f\u6fc0\u3057\u3044\u30d4\u30da\u30c3\u30c6\u30a3\u30f3\u30b0<\/td>\n<td>\u63a5\u7740\u6027\u306e\u5f31\u3044\u7d30\u80de\u304a\u3088\u3073\u6709\u7cf8\u5206\u88c2\u7d30\u80de<\/td>\n<\/tr>\n<tr>\n<td>\u30b9\u30af\u30ec\u30fc\u30d4\u30f3\u30b0<\/td>\n<td>\u7d30\u80de\u30b9\u30af\u30ec\u30fc\u30d1\u30fc<\/td>\n<td>\u30bf\u30f3\u30d1\u30af\u8cea\u5206\u89e3\u9175\u7d20\u306b\u5bfe\u3059\u308b\u611f\u53d7\u6027\u306e\u9ad8\u3044\u7d30\u80de\u7cfb\u3002\u7d30\u80de\u3092\u640d\u50b7\u3059\u308b\u53ef\u80fd\u6027\u3082\u3042\u308a\u307e\u3059\u3002<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"4\">\u9175\u7d20\u7684\u89e3\u96e2<\/td>\n<td>\u30c8\u30ea\u30d7\u30b7\u30f3<\/td>\n<td>\u63a5\u7740\u6027\u306e\u9ad8\u3044\u7d30\u80de<\/td>\n<\/tr>\n<tr>\n<td>\u30c8\u30ea\u30d7\u30b7\u30f3+\u30b3\u30e9\u30b2\u30ca\u30fc\u30bc<\/td>\n<td>\u9ad8\u5bc6\u5ea6\u306e\u57f9\u990a\u7d30\u80de\u3001\u8907\u6570\u306e\u5c64\u3092\u5f62\u6210\u3057\u3066\u3044\u308b\u7d30\u80de\u3001\u7279\u306b\u7dda\u7dad\u82bd\u7d30\u80de\u3002<\/td>\n<\/tr>\n<tr>\n<td>\u30c7\u30a3\u30b9\u30d1\u30fc\u30bc<\/td>\n<td>\u30b3\u30f3\u30d5\u30eb\u30a8\u30f3\u30c8\u306b\u9054\u3057\u305f\u4e0a\u76ae\u7d30\u80de\u306e\u5206\u96e2\u3002\u57f9\u990a\u76bf\u306e\u8868\u9762\u304b\u3089\u3001\u7d30\u80de\u3092\u89e3\u96e2\u3059\u308b\u3053\u3068\u306a\u304f\u3001\u7d30\u80de\u30b7\u30fc\u30c8\u3068\u3057\u3066\u5206\u96e2\u3057\u307e\u3059\u3002<\/td>\n<\/tr>\n<tr>\n<td>TrypLE\u2122 \u89e3\u96e2\u7528\u9175\u7d20<\/td>\n<td>\u63a5\u7740\u6027\u306e\u5f37\u3044\u7d30\u80de\u3002\u30c8\u30ea\u30d7\u30b7\u30f3\u306e\u4ee3\u7528\u3002\u52d5\u7269\u7531\u6765\u3067\u306a\u3044\u8a66\u85ac\u3092\u5fc5\u8981\u3068\u3059\u308b\u5834\u5408\u306b\u4f7f\u7528\u3057\u307e\u3059\u3002<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2>TrypLE\u89e3\u96e2\u7528\u9175\u7d20<\/h2>\n<p><a href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/life-science\/cell-culture\/mammalian-cell-culture\/reagents\/trypsin\/tryple-express.html?CID=bid_clb_cce_r04_jp_cp0000_pjt0000_bid00000_0so_blg_op_awa_oc_s00_cc7_Social_LAB\" target=\"_blank\" rel=\"noopener noreferrer\">Gibco\u2122 TrypLE\u2122 Express\u304a\u3088\u3073Gibco\u2122 TrypLE\u2122 Select<\/a>\u306f\u3001\u5fae\u751f\u7269\u751f\u7523\u3055\u308c\u305f\u7d30\u80de\u89e3\u96e2\u7528\u9175\u7d20\u3067\u3001\u30c8\u30ea\u30d7\u30b7\u30f3\u3068\u540c\u69d8\u306e\u52d5\u614b\u304a\u3088\u3073\u5207\u65ad\u7279\u6027\u3092\u793a\u3057\u307e\u3059\u3002\u7d30\u80de\u306e\u89e3\u96e2\u306b\u304a\u3044\u3066\u306f\u3001\u30d7\u30ed\u30c8\u30b3\u30fc\u30eb\u306e\u5909\u66f4\u3092\u884c\u3046\u3053\u3068\u306a\u304f\u3001\u30c8\u30ea\u30d7\u30b7\u30f3\u3092\u76f4\u63a5TrypLE\u9175\u7d20\u3067\u7f6e\u304d\u63db\u3048\u308b\u3053\u3068\u304c\u53ef\u80fd\u3067\u3059\u304c\u3001\u6700\u826f\u306e\u7d50\u679c\u3092\u5f97\u308b\u305f\u3081\u306b\u306f\u3001\u307e\u305a\u89e3\u96e2\u306e\u305f\u3081\u306e\u30a4\u30f3\u30ad\u30e5\u30d9\u30fc\u30b7\u30e7\u30f3\u6642\u9593\u306e\u6700\u9069\u5316\u3092\u884c\u308f\u308c\u308b\u3053\u3068\u3092\u63a8\u5968\u3057\u307e\u3059\u3002<\/p>\n<p>TrypLE\u9175\u7d20\u306f\u3001\u907a\u4f1d\u5b50\u7d44\u63db\u3048\u306e\u771f\u83cc\u6027\u30c8\u30ea\u30d7\u30b7\u30f3\u69d8\u30bf\u30f3\u30d1\u30af\u8cea\u5206\u89e3\u9175\u7d20\u3067\u3059\u306e\u3067\u3001\u52d5\u7269\u7531\u6765\u3067\u306a\u3044\u8a66\u85ac\u3092\u5fc5\u8981\u3068\u3059\u308b\u5b9f\u9a13\u306b\u306f\u7406\u60f3\u7684\u3067\u3059\u3002TrypLE Express\u304a\u3088\u3073TrypLE Select\u3068\u3001\u30c8\u30ea\u30d7\u30b7\u30f3\u3068\u306e\u6bd4\u8f03\u3092\u4e0b\u8868\u306b\u793a\u3057\u307e\u3059\u3002<\/p>\n<table>\n<caption>\u88684 TrypLE Express\u304a\u3088\u3073TrypLE Select\u3068\u30c8\u30ea\u30d7\u30b7\u30f3\u3068\u306e\u6bd4\u8f03<\/caption>\n<tbody>\n<tr>\n<td style=\"text-align: center\"><strong>TrypLE Express\u304a\u3088\u3073TrypLE Select<\/strong><\/td>\n<td style=\"text-align: center\"><strong>\u30c8\u30ea\u30d7\u30b7\u30f3<\/strong><\/td>\n<\/tr>\n<tr>\n<td>\u52d5\u7269\u304a\u3088\u3073\u30d2\u30c8\u7531\u6765\u306e\u6210\u5206\u306f\u3001\u4e00\u5207\u4e0d\u542b<\/td>\n<td>\u30d6\u30bf\u307e\u305f\u306f\u30a6\u30b7\u7531\u6765<\/td>\n<\/tr>\n<tr>\n<td>\u5ba4\u6e29\u3067\u6700\u4f4e6\u30f5\u6708\u306f\u5b89\u5b9a<\/td>\n<td>\u5ba4\u6e29\u3067\u306f\u4e0d\u5b89\u5b9a<\/td>\n<\/tr>\n<tr>\n<td>\u4e0d\u6d3b\u5316\u306e\u5fc5\u8981\u306a\u3057<\/td>\n<td>\u8840\u6e05\u307e\u305f\u306f\u305d\u306e\u4ed6\u306e\u963b\u5bb3\u5264\u306b\u3088\u308b\u4e0d\u6d3b\u5316\u304c\u5fc5\u8981<\/td>\n<\/tr>\n<tr>\n<td>\u30c8\u30ea\u30d7\u30b7\u30f3\u4e0d\u6d3b\u5316\u5264\u3092\u5fc5\u8981\u306a\u3057<\/td>\n<td>\u30c8\u30ea\u30d7\u30b7\u30f3\u4e0d\u6d3b\u5316\u5264\u304c\u5fc5\u8981<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2>\u3010\u7121\u6599\u30c0\u30a6\u30f3\u30ed\u30fc\u30c9\u3011Gibco\u7d30\u80de\u57f9\u990a\u57fa\u790e\u30cf\u30f3\u30c9\u30d6\u30c3\u30af<\/h2>\n<p>\u7d30\u80de\u57f9\u990a\u306b\u95a2\u3059\u308b\u57fa\u790e\u60c5\u5831\u3092\u89e3\u8aac\u3057\u305f\u30cf\u30f3\u30c9\u30d6\u30c3\u30af\u3092\u3054\u7528\u610f\u3057\u3066\u3044\u307e\u3059\uff08\u65e5\u672c\u8a9e\u7248\u3001\u7d04100\u30da\u30fc\u30b8\uff09\u3002PDF\u30d5\u30a1\u30a4\u30eb\u306e\u30c0\u30a6\u30f3\u30ed\u30fc\u30c9\u3092\u3054\u5e0c\u671b\u306e\u65b9\u306f\u3001\u4e0b\u8a18\u30dc\u30bf\u30f3\u3088\u308a\u304a\u7533\u3057\u8fbc\u307f\u304f\u3060\u3055\u3044\u3002<\/p>\n<p><a class=\"btn btn-red\" href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/global\/forms\/gibco-cell-culture-basics-handbook-form.html?CID=bid_clb_cce_r04_jp_cp0000_pjt0000_bid00000_0so_blg_op_awa_oc_s00_cc7_Social_LAB\" target=\"_blank\" rel=\"noopener\">\u30c0\u30a6\u30f3\u30ed\u30fc\u30c9<\/a><\/p>\n<p>&nbsp;<\/p>\n<p>\u7814\u7a76\u7528\u306b\u306e\u307f\u4f7f\u7528\u3067\u304d\u307e\u3059\u3002\u8a3a\u65ad\u7528\u306b\u306f\u4f7f\u7528\u3044\u305f\u3060\u3051\u307e\u305b\u3093\u3002<\/p>\n","protected":false},"excerpt":{"rendered":"<p>\u7d30\u80de\u57f9\u990a\u306b\u304a\u3051\u308b\u57f9\u990a\u6761\u4ef6\u306f\u3001\u5404\u7d30\u80de\u578b\u306b\u3088\u3063\u3066\u7570\u306a\u308b\u3053\u3068\u306b\u6ce8\u610f\u304c\u5fc5\u8981\u3067\u3059\u3002\u7279\u5b9a\u306e\u7d30\u80de\u578b\u306b\u5fc5\u8981\u3068\u3055\u308c\u308b\u57f9\u990a\u6761\u4ef6\u304b\u3089\u9038\u8131\u3059\u308b\u3053\u3068\u306f\u3001\u7570\u5e38\u306a\u7d30\u80de\u578b\u306e\u767a\u73fe\u304b\u3089\u3001\u7d30\u80de\u57f9\u990a\u306e\u5b8c\u5168\u306a\u5931\u6557\u306b\u81f3\u308b\u69d8\u3005\u306a\u7d50\u679c\u3092\u5f15\u304d\u8d77\u3053\u3059\u53ef\u80fd\u6027\u304c\u3042\u308a\u307e\u3059\u3002\u4eca\u56de\u306f\u3001\u7d30\u80de\u57f9\u990a\u7cfb\u306b\u304a\u3051\u308b\u57f9\u990a\u7d30\u80de\u306e\u901a\u5e38\u306e\u7d99\u4ee3\u306b\u95a2\u3059\u308b\u3001\u77e5\u3063\u3066\u304a\u304f\u3079\u304d\u57fa\u790e\u77e5\u8b58\u3092\u3054\u7d39\u4ecb\u3057\u307e\u3059\u3002<\/p>\n","protected":false},"author":988,"featured_media":2815,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_monsterinsights_skip_tracking":false,"_genesis_hide_title":false,"_genesis_hide_breadcrumbs":false,"_genesis_hide_singular_image":false,"_genesis_hide_footer_widgets":false,"_genesis_custom_body_class":"","_genesis_custom_post_class":"","_genesis_layout":"","_jetpack_newsletter_access":"","_jetpack_dont_email_post_to_subs":false,"_jetpack_newsletter_tier_id":0,"_jetpack_memberships_contains_paywalled_content":false,"_jetpack_feature_clip_id":0,"_jetpack_memberships_contains_paid_content":false,"footnotes":"","jetpack_post_was_ever_published":false},"categories":[159],"tags":[23],"division":[],"class_list":{"0":"post-509","1":"post","2":"type-post","3":"status-publish","4":"format-standard","5":"has-post-thumbnail","7":"category-cell","8":"tag-cell-culture","9":"entry"},"_selected_authors":"","_selected_reviewers":"","acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v27.8 (Yoast SEO v27.8) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>\u57f9\u990a\u7d30\u80de\u306e\u7d99\u4ee3\u306b\u95a2\u3059\u308b\u77e5\u3063\u3066\u304a\u304f\u3079\u304d\u57fa\u790e\u77e5\u8b58 - Learning at the Bench<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/guidelines-for-maintaining-cultured-cells\/\" \/>\n<meta property=\"og:locale\" content=\"ja_JP\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"\u57f9\u990a\u7d30\u80de\u306e\u7d99\u4ee3\u306b\u95a2\u3059\u308b\u77e5\u3063\u3066\u304a\u304f\u3079\u304d\u57fa\u790e\u77e5\u8b58\" \/>\n<meta property=\"og:description\" content=\"\u7d30\u80de\u57f9\u990a\u306b\u304a\u3051\u308b\u57f9\u990a\u6761\u4ef6\u306f\u3001\u5404\u7d30\u80de\u578b\u306b\u3088\u3063\u3066\u7570\u306a\u308b\u3053\u3068\u306b\u6ce8\u610f\u304c\u5fc5\u8981\u3067\u3059\u3002\u7279\u5b9a\u306e\u7d30\u80de\u578b\u306b\u5fc5\u8981\u3068\u3055\u308c\u308b\u57f9\u990a\u6761\u4ef6\u304b\u3089\u9038\u8131\u3059\u308b\u3053\u3068\u306f\u3001\u7570\u5e38\u306a\u7d30\u80de\u578b\u306e\u767a\u73fe\u304b\u3089\u3001\u7d30\u80de\u57f9\u990a\u306e\u5b8c\u5168\u306a\u5931\u6557\u306b\u81f3\u308b\u69d8\u3005\u306a\u7d50\u679c\u3092\u5f15\u304d\u8d77\u3053\u3059\u53ef\u80fd\u6027\u304c\u3042\u308a\u307e\u3059\u3002\u4eca\u56de\u306f\u3001\u7d30\u80de\u57f9\u990a\u7cfb\u306b\u304a\u3051\u308b\u57f9\u990a\u7d30\u80de\u306e\u901a\u5e38\u306e\u7d99\u4ee3\u306b\u95a2\u3059\u308b\u3001\u77e5\u3063\u3066\u304a\u304f\u3079\u304d\u57fa\u790e\u77e5\u8b58\u3092\u3054\u7d39\u4ecb\u3057\u307e\u3059\u3002\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/guidelines-for-maintaining-cultured-cells\/\" \/>\n<meta property=\"og:site_name\" content=\"Learning at the Bench\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/ThermoFisherJapan\" \/>\n<meta property=\"article:published_time\" content=\"2016-11-08T00:00:00+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2025-02-26T07:52:30+00:00\" \/>\n<meta property=\"og:image\" content=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/guidelines-for-maintaining-cultured-cells-title.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"1200\" \/>\n\t<meta property=\"og:image:height\" content=\"631\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"LATB Staff\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:creator\" content=\"@ThermoFisherJP\" \/>\n<meta name=\"twitter:site\" content=\"@ThermoFisherJP\" \/>\n<meta name=\"twitter:label1\" content=\"\u57f7\u7b46\u8005\" \/>\n\t<meta name=\"twitter:data1\" content=\"LATB Staff\" \/>\n\t<meta name=\"twitter:label2\" content=\"\u63a8\u5b9a\u8aad\u307f\u53d6\u308a\u6642\u9593\" \/>\n\t<meta name=\"twitter:data2\" content=\"17\u5206\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/guidelines-for-maintaining-cultured-cells\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/guidelines-for-maintaining-cultured-cells\\\/\"},\"author\":{\"name\":\"LATB Staff\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#\\\/schema\\\/person\\\/00a095a01d54afcdf9457465feb04f7d\"},\"headline\":\"\u57f9\u990a\u7d30\u80de\u306e\u7d99\u4ee3\u306b\u95a2\u3059\u308b\u77e5\u3063\u3066\u304a\u304f\u3079\u304d\u57fa\u790e\u77e5\u8b58\",\"datePublished\":\"2016-11-08T00:00:00+00:00\",\"dateModified\":\"2025-02-26T07:52:30+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/guidelines-for-maintaining-cultured-cells\\\/\"},\"wordCount\":286,\"commentCount\":0,\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/guidelines-for-maintaining-cultured-cells\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2019\\\/07\\\/guidelines-for-maintaining-cultured-cells-title.jpg\",\"keywords\":[\"\u7d30\u80de\u57f9\u990a\"],\"articleSection\":[\"\u7d30\u80de\u57f9\u990a\u30fb\u30a4\u30e1\u30fc\u30b8\u30f3\u30b0\"],\"inLanguage\":\"ja\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/guidelines-for-maintaining-cultured-cells\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/guidelines-for-maintaining-cultured-cells\\\/\",\"url\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/guidelines-for-maintaining-cultured-cells\\\/\",\"name\":\"\u57f9\u990a\u7d30\u80de\u306e\u7d99\u4ee3\u306b\u95a2\u3059\u308b\u77e5\u3063\u3066\u304a\u304f\u3079\u304d\u57fa\u790e\u77e5\u8b58 - Learning at the Bench\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/guidelines-for-maintaining-cultured-cells\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/guidelines-for-maintaining-cultured-cells\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2019\\\/07\\\/guidelines-for-maintaining-cultured-cells-title.jpg\",\"datePublished\":\"2016-11-08T00:00:00+00:00\",\"dateModified\":\"2025-02-26T07:52:30+00:00\",\"author\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#\\\/schema\\\/person\\\/00a095a01d54afcdf9457465feb04f7d\"},\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/guidelines-for-maintaining-cultured-cells\\\/#breadcrumb\"},\"inLanguage\":\"ja\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/guidelines-for-maintaining-cultured-cells\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"ja\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/guidelines-for-maintaining-cultured-cells\\\/#primaryimage\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2019\\\/07\\\/guidelines-for-maintaining-cultured-cells-title.jpg\",\"contentUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2019\\\/07\\\/guidelines-for-maintaining-cultured-cells-title.jpg\",\"width\":1200,\"height\":631,\"caption\":\"guidelines-for-maintaining-cultured-cells-title\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/guidelines-for-maintaining-cultured-cells\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"\u57f9\u990a\u7d30\u80de\u306e\u7d99\u4ee3\u306b\u95a2\u3059\u308b\u77e5\u3063\u3066\u304a\u304f\u3079\u304d\u57fa\u790e\u77e5\u8b58\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#website\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/\",\"name\":\"Learning at the Bench\",\"description\":\"\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"ja\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#\\\/schema\\\/person\\\/00a095a01d54afcdf9457465feb04f7d\",\"name\":\"LATB Staff\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"ja\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/8803277856c8b753feb4217dff0f9953327452df1a615c3c88b2f9864efb2ddd?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/8803277856c8b753feb4217dff0f9953327452df1a615c3c88b2f9864efb2ddd?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/8803277856c8b753feb4217dff0f9953327452df1a615c3c88b2f9864efb2ddd?s=96&d=mm&r=g\",\"caption\":\"LATB Staff\"},\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/author\\\/latbstaff\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"\u57f9\u990a\u7d30\u80de\u306e\u7d99\u4ee3\u306b\u95a2\u3059\u308b\u77e5\u3063\u3066\u304a\u304f\u3079\u304d\u57fa\u790e\u77e5\u8b58 - Learning at the Bench","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/guidelines-for-maintaining-cultured-cells\/","og_locale":"ja_JP","og_type":"article","og_title":"\u57f9\u990a\u7d30\u80de\u306e\u7d99\u4ee3\u306b\u95a2\u3059\u308b\u77e5\u3063\u3066\u304a\u304f\u3079\u304d\u57fa\u790e\u77e5\u8b58","og_description":"\u7d30\u80de\u57f9\u990a\u306b\u304a\u3051\u308b\u57f9\u990a\u6761\u4ef6\u306f\u3001\u5404\u7d30\u80de\u578b\u306b\u3088\u3063\u3066\u7570\u306a\u308b\u3053\u3068\u306b\u6ce8\u610f\u304c\u5fc5\u8981\u3067\u3059\u3002\u7279\u5b9a\u306e\u7d30\u80de\u578b\u306b\u5fc5\u8981\u3068\u3055\u308c\u308b\u57f9\u990a\u6761\u4ef6\u304b\u3089\u9038\u8131\u3059\u308b\u3053\u3068\u306f\u3001\u7570\u5e38\u306a\u7d30\u80de\u578b\u306e\u767a\u73fe\u304b\u3089\u3001\u7d30\u80de\u57f9\u990a\u306e\u5b8c\u5168\u306a\u5931\u6557\u306b\u81f3\u308b\u69d8\u3005\u306a\u7d50\u679c\u3092\u5f15\u304d\u8d77\u3053\u3059\u53ef\u80fd\u6027\u304c\u3042\u308a\u307e\u3059\u3002\u4eca\u56de\u306f\u3001\u7d30\u80de\u57f9\u990a\u7cfb\u306b\u304a\u3051\u308b\u57f9\u990a\u7d30\u80de\u306e\u901a\u5e38\u306e\u7d99\u4ee3\u306b\u95a2\u3059\u308b\u3001\u77e5\u3063\u3066\u304a\u304f\u3079\u304d\u57fa\u790e\u77e5\u8b58\u3092\u3054\u7d39\u4ecb\u3057\u307e\u3059\u3002","og_url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/guidelines-for-maintaining-cultured-cells\/","og_site_name":"Learning at the Bench","article_publisher":"https:\/\/www.facebook.com\/ThermoFisherJapan","article_published_time":"2016-11-08T00:00:00+00:00","article_modified_time":"2025-02-26T07:52:30+00:00","og_image":[{"width":1200,"height":631,"url":"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/guidelines-for-maintaining-cultured-cells-title.jpg","type":"image\/jpeg"}],"author":"LATB Staff","twitter_card":"summary_large_image","twitter_creator":"@ThermoFisherJP","twitter_site":"@ThermoFisherJP","twitter_misc":{"\u57f7\u7b46\u8005":"LATB Staff","\u63a8\u5b9a\u8aad\u307f\u53d6\u308a\u6642\u9593":"17\u5206"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/guidelines-for-maintaining-cultured-cells\/#article","isPartOf":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/guidelines-for-maintaining-cultured-cells\/"},"author":{"name":"LATB Staff","@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#\/schema\/person\/00a095a01d54afcdf9457465feb04f7d"},"headline":"\u57f9\u990a\u7d30\u80de\u306e\u7d99\u4ee3\u306b\u95a2\u3059\u308b\u77e5\u3063\u3066\u304a\u304f\u3079\u304d\u57fa\u790e\u77e5\u8b58","datePublished":"2016-11-08T00:00:00+00:00","dateModified":"2025-02-26T07:52:30+00:00","mainEntityOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/guidelines-for-maintaining-cultured-cells\/"},"wordCount":286,"commentCount":0,"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/guidelines-for-maintaining-cultured-cells\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/guidelines-for-maintaining-cultured-cells-title.jpg","keywords":["\u7d30\u80de\u57f9\u990a"],"articleSection":["\u7d30\u80de\u57f9\u990a\u30fb\u30a4\u30e1\u30fc\u30b8\u30f3\u30b0"],"inLanguage":"ja","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/guidelines-for-maintaining-cultured-cells\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/guidelines-for-maintaining-cultured-cells\/","url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/guidelines-for-maintaining-cultured-cells\/","name":"\u57f9\u990a\u7d30\u80de\u306e\u7d99\u4ee3\u306b\u95a2\u3059\u308b\u77e5\u3063\u3066\u304a\u304f\u3079\u304d\u57fa\u790e\u77e5\u8b58 - Learning at the Bench","isPartOf":{"@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/guidelines-for-maintaining-cultured-cells\/#primaryimage"},"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/guidelines-for-maintaining-cultured-cells\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/guidelines-for-maintaining-cultured-cells-title.jpg","datePublished":"2016-11-08T00:00:00+00:00","dateModified":"2025-02-26T07:52:30+00:00","author":{"@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#\/schema\/person\/00a095a01d54afcdf9457465feb04f7d"},"breadcrumb":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/guidelines-for-maintaining-cultured-cells\/#breadcrumb"},"inLanguage":"ja","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/guidelines-for-maintaining-cultured-cells\/"]}]},{"@type":"ImageObject","inLanguage":"ja","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/guidelines-for-maintaining-cultured-cells\/#primaryimage","url":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/guidelines-for-maintaining-cultured-cells-title.jpg","contentUrl":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/guidelines-for-maintaining-cultured-cells-title.jpg","width":1200,"height":631,"caption":"guidelines-for-maintaining-cultured-cells-title"},{"@type":"BreadcrumbList","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/guidelines-for-maintaining-cultured-cells\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/"},{"@type":"ListItem","position":2,"name":"\u57f9\u990a\u7d30\u80de\u306e\u7d99\u4ee3\u306b\u95a2\u3059\u308b\u77e5\u3063\u3066\u304a\u304f\u3079\u304d\u57fa\u790e\u77e5\u8b58"}]},{"@type":"WebSite","@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#website","url":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/","name":"Learning at the Bench","description":"","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"ja"},{"@type":"Person","@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#\/schema\/person\/00a095a01d54afcdf9457465feb04f7d","name":"LATB Staff","image":{"@type":"ImageObject","inLanguage":"ja","@id":"https:\/\/secure.gravatar.com\/avatar\/8803277856c8b753feb4217dff0f9953327452df1a615c3c88b2f9864efb2ddd?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/8803277856c8b753feb4217dff0f9953327452df1a615c3c88b2f9864efb2ddd?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/8803277856c8b753feb4217dff0f9953327452df1a615c3c88b2f9864efb2ddd?s=96&d=mm&r=g","caption":"LATB Staff"},"url":"https:\/\/admin.acceleratingscience.com\/author\/latbstaff\/"}]}},"taxonomy_info":{"category":[{"value":159,"label":"\u7d30\u80de\u57f9\u990a\u30fb\u30a4\u30e1\u30fc\u30b8\u30f3\u30b0"}],"post_tag":[{"value":23,"label":"\u7d30\u80de\u57f9\u990a"}]},"featured_image_src_large":["https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/guidelines-for-maintaining-cultured-cells-title-1024x538.jpg",760,399,true],"author_info":{"display_name":"LATB Staff","author_link":"https:\/\/admin.acceleratingscience.com\/author\/latbstaff\/"},"comment_info":0,"category_info":[{"term_id":159,"name":"\u7d30\u80de\u57f9\u990a\u30fb\u30a4\u30e1\u30fc\u30b8\u30f3\u30b0","slug":"cell","term_group":0,"term_taxonomy_id":159,"taxonomy":"category","description":"","parent":0,"count":103,"filter":"raw","meta":[],"cat_ID":159,"category_count":103,"category_description":"","cat_name":"\u7d30\u80de\u57f9\u990a\u30fb\u30a4\u30e1\u30fc\u30b8\u30f3\u30b0","category_nicename":"cell","category_parent":0}],"tag_info":[{"term_id":23,"name":"\u7d30\u80de\u57f9\u990a","slug":"cell-culture","term_group":0,"term_taxonomy_id":23,"taxonomy":"post_tag","description":"","parent":0,"count":64,"filter":"raw","meta":[]}],"jetpack-related-posts":[{"id":23098,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/cell-culture-cell-culture-basic-bid-ts-mbr-25059\/","url_meta":{"origin":509,"position":0},"title":"\u7d30\u80de\u57f9\u990a\u7528\u306e\u57f9\u5730\uff5e\u521d\u5fc3\u8005\u5fc5\u898b\uff01\u7d30\u80de\u57f9\u990a\u306e\u5b8c\u5168\u30b5\u30dd\u30fc\u30c8\u30ac\u30a4\u30c9 \u305d\u306e4","author":"LatB Staff","date":"2025\u5e7410\u67082\u65e5","format":false,"excerpt":"\u300c\u7d30\u80de\u57f9\u990a\u306e\u5b8c\u5168\u30b5\u30dd\u30fc\u30c8\u30ac\u30a4\u30c9\u300d\u306f\u3001\u7d30\u80de\u57f9\u990a\u306b\u521d\u3081\u3066\u6311\u6226\u3055\u308c\u308b\u65b9\u3084\u3001\u307e\u3060\u7d4c\u9a13\u306e\u6d45\u3044\u65b9\u306b\u5411\u3051\u3066\u3001\u57fa\u790e\u77e5\u2026","rel":"","context":"\u7d30\u80de\u57f9\u990a\u30fb\u30a4\u30e1\u30fc\u30b8\u30f3\u30b0","block_context":{"text":"\u7d30\u80de\u57f9\u990a\u30fb\u30a4\u30e1\u30fc\u30b8\u30f3\u30b0","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/cell\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/09\/cell-culture-cell-culture-basic-bid-ts-mbr-25059_eycatch.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/09\/cell-culture-cell-culture-basic-bid-ts-mbr-25059_eycatch.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/09\/cell-culture-cell-culture-basic-bid-ts-mbr-25059_eycatch.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/09\/cell-culture-cell-culture-basic-bid-ts-mbr-25059_eycatch.jpg?resize=700%2C400&ssl=1 2x"},"classes":[]},{"id":24152,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/cell-culture-protein-expression-bid-ts-mbr-25074\/","url_meta":{"origin":509,"position":1},"title":"\u30bf\u30f3\u30d1\u30af\u7523\u751f\u3084\u30a6\u30a4\u30eb\u30b9\u7523\u751f\u3092\u76ee\u7684\u3068\u3057\u305f\u9ad8\u5bc6\u5ea6\u7d30\u80de\u57f9\u990a\u30b7\u30b9\u30c6\u30e0\u5c0e\u5165\u306e\u7b2c\u4e00\u6b69\uff1a\u7d30\u80de\u682a\u306e\u7d99\u4ee3\u3068\u51cd\u7d50\u4fdd\u5b58\u7de8","author":"LatB Staff","date":"2025\u5e7412\u67083\u65e5","format":false,"excerpt":"\u9ad8\u5bc6\u5ea6\u7d30\u80de\u57f9\u990a\u30b7\u30b9\u30c6\u30e0\u3067\u306f\u3001\u5c02\u7528\u306e\u6d6e\u904a\u7d30\u80de\u682a\u3092\u7528\u3044\u3066\u6c7a\u3081\u3089\u308c\u305f\u624b\u9806\u3067\u57f9\u990a\u3057\u307e\u3059\u3002\u5b89\u5b9a\u7684\u306b\u904b\u7528\u3059\u308b\u305f\u3081\u2026","rel":"","context":"\u7d30\u80de\u57f9\u990a\u30fb\u30a4\u30e1\u30fc\u30b8\u30f3\u30b0","block_context":{"text":"\u7d30\u80de\u57f9\u990a\u30fb\u30a4\u30e1\u30fc\u30b8\u30f3\u30b0","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/cell\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/11\/cell-culture-protein-expression-bid-ts-mbr-25074_eycatch.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/11\/cell-culture-protein-expression-bid-ts-mbr-25074_eycatch.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/11\/cell-culture-protein-expression-bid-ts-mbr-25074_eycatch.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/11\/cell-culture-protein-expression-bid-ts-mbr-25074_eycatch.jpg?resize=700%2C400&ssl=1 2x"},"classes":[]},{"id":23457,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/cell-culture-cell-culture-basic-bid-ts-mbr-25063\/","url_meta":{"origin":509,"position":2},"title":"\u7d30\u80de\u57f9\u990a\u7528\u306e\u8840\u6e05\uff08FBS\uff09\u3068\u6297\u751f\u7269\u8cea\u306e\u30dd\u30a4\u30f3\u30c8\uff5e\u7d30\u80de\u57f9\u990a\u306e\u5b8c\u5168\u30b5\u30dd\u30fc\u30c8\u30ac\u30a4\u30c9 \u305d\u306e5","author":"LatB Staff","date":"2025\u5e7410\u670822\u65e5","format":false,"excerpt":"\u300c\u7d30\u80de\u57f9\u990a\u306e\u5b8c\u5168\u30b5\u30dd\u30fc\u30c8\u30ac\u30a4\u30c9\u300d\u306f\u3001\u7d30\u80de\u57f9\u990a\u306b\u521d\u3081\u3066\u6311\u6226\u3059\u308b\u65b9\u3084\u3001\u307e\u3060\u7d4c\u9a13\u306e\u6d45\u3044\u65b9\u306b\u5411\u3051\u3066\u3001\u57fa\u790e\u77e5\u8b58\u2026","rel":"","context":"\u7d30\u80de\u57f9\u990a\u30fb\u30a4\u30e1\u30fc\u30b8\u30f3\u30b0","block_context":{"text":"\u7d30\u80de\u57f9\u990a\u30fb\u30a4\u30e1\u30fc\u30b8\u30f3\u30b0","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/cell\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/10\/cell-culture-cell-culture-basic-bid-ts-mbr-25063_eyecatch-scaled.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/10\/cell-culture-cell-culture-basic-bid-ts-mbr-25063_eyecatch-scaled.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/10\/cell-culture-cell-culture-basic-bid-ts-mbr-25063_eyecatch-scaled.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/10\/cell-culture-cell-culture-basic-bid-ts-mbr-25063_eyecatch-scaled.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/10\/cell-culture-cell-culture-basic-bid-ts-mbr-25063_eyecatch-scaled.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/10\/cell-culture-cell-culture-basic-bid-ts-mbr-25063_eyecatch-scaled.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":25608,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/cell-culture-basic-cell-culture-bpg-26026\/","url_meta":{"origin":509,"position":3},"title":"\u3010\u7b2c3\u56de\u3011Gibco\u57f9\u5730 60\u5e74\u306e\u30a4\u30ce\u30d9\u30fc\u30b7\u30e7\u30f3\u3002\u7d30\u80de\u57f9\u990a\u306e\u6b74\u53f2\u306f\u57f9\u5730\u306e\u6b74\u53f2\u3002","author":"LatB Staff","date":"2026\u5e7410\u67087\u65e5","format":false,"excerpt":"\u3053\u306e\u30d6\u30ed\u30b0\u3067\u306f\u3001\u30d0\u30a4\u30aa\u30d7\u30ed\u30c0\u30af\u30b7\u30e7\u30f3\u30c1\u30fc\u30e0\u304c\u533b\u85ac\u54c1\u88fd\u9020\u306b\u95a2\u9023\u3059\u308b\u3055\u307e\u3056\u307e\u306a\u30c8\u30d4\u30c3\u30af\u3092\u30b7\u30ea\u30fc\u30ba\u3067\u3054\u7d39\u4ecb\u2026","rel":"","context":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","block_context":{"text":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/mol-bio\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/08\/cell-culture-basic-cell-culture-bpg-26026_eyecatch.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/08\/cell-culture-basic-cell-culture-bpg-26026_eyecatch.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/08\/cell-culture-basic-cell-culture-bpg-26026_eyecatch.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/08\/cell-culture-basic-cell-culture-bpg-26026_eyecatch.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/08\/cell-culture-basic-cell-culture-bpg-26026_eyecatch.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/08\/cell-culture-basic-cell-culture-bpg-26026_eyecatch.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":23765,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/cell-culture-cell-count-bid-ts-mbr-25065\/","url_meta":{"origin":509,"position":4},"title":"\u3010\u3084\u3063\u3066\u307f\u305f\u3011\u51dd\u96c6\u3057\u3084\u3059\u3044\u7d30\u80de\u3092\u3042\u306e\u624b\u3053\u306e\u624b\u3067\u307b\u3050\u3057\u3066\u307f\u305f","author":"LatB Staff","date":"2025\u5e7411\u67084\u65e5","format":false,"excerpt":"\u7d30\u80de\u57f9\u990a\u5b9f\u9a13\u306b\u304a\u3044\u3066\u3001\u7d30\u80de\u6570\u3084\u751f\u7d30\u80de\u7387\u30fb\u6b7b\u7d30\u80de\u7387\u306e\u6e2c\u5b9a\uff08\u3044\u308f\u3086\u308b\u30bb\u30eb\u30ab\u30a6\u30f3\u30c8\uff09\u306f\u91cd\u8981\u306a\u30b9\u30c6\u30c3\u30d7\u3067\u3059\u3002\u2026","rel":"","context":"\u7d30\u80de\u57f9\u990a\u30fb\u30a4\u30e1\u30fc\u30b8\u30f3\u30b0","block_context":{"text":"\u7d30\u80de\u57f9\u990a\u30fb\u30a4\u30e1\u30fc\u30b8\u30f3\u30b0","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/cell\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/10\/cell-culture-cell-count-bid-ts-mbr-25065_eyecatch-scaled.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/10\/cell-culture-cell-count-bid-ts-mbr-25065_eyecatch-scaled.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/10\/cell-culture-cell-count-bid-ts-mbr-25065_eyecatch-scaled.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/10\/cell-culture-cell-count-bid-ts-mbr-25065_eyecatch-scaled.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/10\/cell-culture-cell-count-bid-ts-mbr-25065_eyecatch-scaled.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/10\/cell-culture-cell-count-bid-ts-mbr-25065_eyecatch-scaled.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":25565,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/exosome-antibody-ts-r-25068_\/","url_meta":{"origin":509,"position":5},"title":"\u3010\u7b2c8\u56de\u3011\u30a8\u30af\u30bd\u30bd\u30fc\u30e0\u30b5\u30d6\u30bf\u30a4\u30d7\u306e\u5206\u753b\u6cd5 \uff1a \u30a6\u30a7\u30b9\u30bf\u30f3\u30d6\u30ed\u30c3\u30c8\uff0fqRT-PCR\uff0f\u30b7\u30fc\u30b1\u30f3\u30b9\u89e3\u6790\u306b\u9069\u3057\u305f\u5206\u753b\u65b9\u6cd5","author":"LatB Staff","date":"2026\u5e749\u670829\u65e5","format":false,"excerpt":"\u672c\u7a3f\u3067\u306f\u3001\u30a8\u30af\u30bd\u30bd\u30fc\u30e0\u819c\u4e0a\u306e\u7279\u5b9a\u306e\u30bf\u30f3\u30d1\u30af\u8cea\u3092\u6a19\u7684\u3068\u3057\u305f\u514d\u75ab\u5438\u7740\u6cd5\u306b\u57fa\u3065\u304f\u5206\u753b\u624b\u6cd5\u3092\u7d39\u4ecb\u3057\u307e\u3059\u3002\u30a8\u30af\u2026","rel":"","context":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","block_context":{"text":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/mol-bio\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25019_eyecatch.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25019_eyecatch.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25019_eyecatch.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25019_eyecatch.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25019_eyecatch.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25019_eyecatch.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]}],"jetpack_sharing_enabled":true,"amp_enabled":true,"jetpack_featured_media_url":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/guidelines-for-maintaining-cultured-cells-title.jpg","_links":{"self":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/posts\/509","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/users\/988"}],"replies":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/comments?post=509"}],"version-history":[{"count":0,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/posts\/509\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/media\/2815"}],"wp:attachment":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/media?parent=509"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/categories?post=509"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/tags?post=509"},{"taxonomy":"division","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/division?post=509"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}