{"id":554,"date":"2017-01-19T00:00:00","date_gmt":"2017-01-19T00:00:00","guid":{"rendered":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/principle-and-factors-of-ion-exchange-separation\/"},"modified":"2023-08-17T15:09:33","modified_gmt":"2023-08-17T06:09:33","slug":"principle-and-factors-of-ion-exchange-separation","status":"publish","type":"post","link":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/principle-and-factors-of-ion-exchange-separation\/","title":{"rendered":"\u30a4\u30aa\u30f3\u4ea4\u63db\u5206\u96e2\u306e\u539f\u7406\u3068\u5206\u96e2\u306b\u5f71\u97ff\u3059\u308b4\u3064\u306e\u56e0\u5b50\u3068\u306f\uff1f"},"content":{"rendered":"<p>\u30a4\u30aa\u30f3\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc\u306e\u5206\u96e2\u6cd5\u3068\u3057\u3066\u4e3b\u306b\u30a4\u30aa\u30f3\u4ea4\u63db\u304c\u7528\u3044\u3089\u308c\u3066\u3044\u307e\u3059\u304c\u3001\u539f\u7406\u304c\u308f\u304b\u308b\u3068\u6e2c\u5b9a\u76ee\u7684\u306b\u5408\u3063\u305f\u5206\u96e2\u306e\u8abf\u7bc0\u3084\u30ab\u30e9\u30e0\u306e\u9078\u629e\u306b\u5f79\u7acb\u3061\u307e\u3059\u3002<strong>\u4eca\u56de\u306f\u3001\u30a4\u30aa\u30f3\u4ea4\u63db\u5206\u96e2\u306e\u539f\u7406\u306e\u8aac\u660e\u3068\u30a4\u30aa\u30f3\u4ea4\u63db\u5206\u96e2\u306b\u5f71\u97ff\u3059\u308b4\u3064\u306e\u56e0\u5b50\u3092\u3054\u7d39\u4ecb\u3057\u307e\u3059\u3002<\/strong><\/p>\n<h2>\u30a4\u30aa\u30f3\u4ea4\u63db\u5206\u96e2\u306e\u539f\u7406<\/h2>\n<p><strong>\u30a4\u30aa\u30f3\u4ea4\u63db\u5206\u96e2\u306f\u3001\u30a4\u30aa\u30f3\u4ea4\u63db\u57fa\u3068\u96fb\u89e3\u8cea\u6eb6\u6db2\u3068\u306e\u9593\u3067\u3001\u30a4\u30aa\u30f3\u6210\u5206\u304c\u5438\u7740\u3068\u8131\u96e2\u3092\u7e70\u308a\u8fd4\u3059\u3053\u3068\u306b\u3088\u3063\u3066\u8d77\u3053\u308a\u307e\u3059\u3002<\/strong>\u9670\u30a4\u30aa\u30f3\u4ea4\u63db\u5206\u96e2\u306e\u5834\u5408\u3001\u305f\u3068\u3048\u3070\u3001\u7b2c\uff14\u7d1a\u30a2\u30f3\u30e2\u30cb\u30a6\u30e0\u57fa\u304c\u4fee\u98fe\u3055\u308c\u305f\u30a4\u30aa\u30f3\u4ea4\u63db\u4f53\u304c\u5145\u586b\u3055\u308c\u305f\u30ab\u30e9\u30e0\u3068\u3001\u70ad\u9178\u30ca\u30c8\u30ea\u30a6\u30e0\u306a\u3069\u306e\u30a2\u30eb\u30ab\u30ea\u6027\u6eb6\u6db2\u306e\u6eb6\u96e2\u6db2\u3092\u7528\u3044\u308b\u3068\u3057\u307e\u3059\u3002\u30ab\u30e9\u30e0\u5185\u3067\u306f\u3001\u6eb6\u96e2\u6db2\u4e2d\u306e\u70ad\u9178\u30a4\u30aa\u30f3\uff08CO<sub>3<\/sub><sup>2-<\/sup>\uff09 \u304c\u30a4\u30aa\u30f3\u4ea4\u63db\u57fa\u4e0a\u3067\u5438\u7740\u3068\u8131\u96e2\u3092\u7e70\u308a\u8fd4\u3057\u3066\u3044\u307e\u3059\uff08\u56f31-1\uff09\u3002\u305d\u3053\u3078\u3001\u6e2c\u5b9a\u30a4\u30aa\u30f3\u3001\u305f\u3068\u3048\u3070\u3001\u5869\u5316\u7269\u30a4\u30aa\u30f3\uff08Cl<sup>&#8211;<\/sup>\uff09\u3068\u786b\u9178\u30a4\u30aa\u30f3\uff08SO<sub>4<\/sub><sup>2-<\/sup>\uff09 \u304c\u5c0e\u5165\u3055\u308c\u308b\u3068\u3001CO<sub>3<\/sub><sup>2-<\/sup>\u306b\u4ee3\u308f\u3063\u3066Cl<sup>&#8211;<\/sup>\u3068SO<sub>4<\/sub><sup>2-<\/sup>\u304c\u30a4\u30aa\u30f3\u4ea4\u63db\u57fa\u3068\u5438\u7740\u3057\u307e\u3059\uff08\u56f31-2\uff09\u3002\u6eb6\u96e2\u6db2\u304c\u9023\u7d9a\u7684\u306b\u6d41\u308c\u3066\u3044\u308b\u306e\u3067\u3001\u3044\u3063\u305f\u3093\u5438\u7740\u3057\u305fCl<sup>&#8211;<\/sup>\u3068SO<sub>4<\/sub><sup>2-<\/sup>\u306f\u9806\u6b21CO<sub>3<\/sub><sup>2-<\/sup>\u306b\u7f6e\u304d\u63db\u3048\u3089\u308c\u307e\u3059\uff08\u56f31-3\uff09\u3002\u8131\u96e2\u3057\u305fCl<sup>&#8211;<\/sup>\u3068SO<sub>4<\/sub><sup>2-<\/sup>\u306f\u6b21\u306e\u30a4\u30aa\u30f3\u4ea4\u63db\u57fa\u306b\u5438\u7740\u3057\u3001\u307e\u305fCO<sub>3<\/sub><sup>2-<\/sup>\u306b\u7f6e\u304d\u63db\u3048\u3089\u308c\u3001\u307e\u305f\u5438\u7740\u3057\u2026\u3068\u5438\u7740\u3068\u8131\u96e2\u3092\u7e70\u308a\u8fd4\u3057\u3066\u3001\u6700\u5f8c\u306b\u306f\u30ab\u30e9\u30e0\u304b\u3089\u6eb6\u51fa\u3055\u308c\u307e\u3059\u3002<\/p>\n<div id=\"attachment_1626\" style=\"width: 806px\" class=\"wp-caption aligncenter\"><a href=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/principle-and-factors-of-ion-exchange-separation-fig1.png\" rel=\"attachment wp-att-1626\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-1626\" class=\"size-full wp-image-1626\" src=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/principle-and-factors-of-ion-exchange-separation-fig1.png\" alt=\"principle-and-factors-of-ion-exchange-separation-fig1\" width=\"796\" height=\"276\" \/><\/a><p id=\"caption-attachment-1626\" class=\"wp-caption-text\">\u56f31 \u9670\u30a4\u30aa\u30f3\u4ea4\u63db\u539f\u7406\u56f3<\/p><\/div>\n<p><strong>\u5438\u7740\u3068\u8131\u96e2\u3092\u7e70\u308a\u8fd4\u3059\u969b\u306b\u5206\u96e2\u304c\u8d77\u3053\u308a\u307e\u3059\u3002\u5206\u96e2\u306f\u3001Cl<sup>&#8211;<\/sup>\u3068SO<sub>4<\/sub><sup>2-<\/sup>\u306e\u30a4\u30aa\u30f3\u4ea4\u63db\u57fa\u3084\u6eb6\u96e2\u6db2\u3068\u306e\u89aa\u548c\u6027\u306e\u9055\u3044\u306b\u3088\u3063\u3066\u8d77\u3053\u308a\u307e\u3059\u3002<\/strong>\u5206\u96e2\u306e\u30a4\u30e1\u30fc\u30b8\u3092\u56f32 \u306b\u793a\u3057\u307e\u3059\u3002\u4e00\u822c\u306b\u3001\u96fb\u8377\u6570\u306e\u5927\u304d\u3044\u30a4\u30aa\u30f3\u307b\u3069\u30a4\u30aa\u30f3\u4ea4\u63db\u57fa\u3068\u306e\u9759\u96fb\u7684\u76f8\u4e92\u4f5c\u7528\u304c\u5927\u304d\u3044\u305f\u3081\u3001\u5f37\u304f\u5438\u7740\u3057\u307e\u3059\u3002\u307e\u305f\u3001\u30a4\u30aa\u30f3\u306e\u758e\u6c34\u6027\u306e\u5f71\u97ff\u3082\u5927\u304d\u304f\u3001\u758e\u6c34\u6027\u304c\u9ad8\u3044\u5834\u5408\u306f\u4fdd\u6301\u304c\u5f37\u304f\u306a\u308a\u307e\u3059\u3002\u30a4\u30aa\u30f3\u534a\u5f84\u306e\u5927\u304d\u3044\u30a4\u30aa\u30f3\u306f\u3001\u534a\u5f84\u306e\u5c0f\u3055\u3044\u30a4\u30aa\u30f3\u306b\u6bd4\u3079\u30a4\u30aa\u30f3\u4ea4\u63db\u57fa\u306b\u5f37\u304f\u5438\u7740\u3057\u307e\u3059\u3002\u3053\u306e\u305f\u3081\u3001<strong>1 \u4fa1\u306e\u9670\u30a4\u30aa\u30f3\u306e\u30a4\u30aa\u30f3\u4ea4\u63db\u4f53\u3078\u306e\u5438\u7740\u306f\u3001F<sup>&#8211;<\/sup>&lt;Cl<sup>&#8211;<\/sup>&lt;Br<sup>&#8211;<\/sup>&lt;I<sup>&#8211;<\/sup>\u30011 \u4fa1\u306e\u967d\u30a4\u30aa\u30f3\u306fLi<sup>+<\/sup>&lt;Na<sup>+<\/sup>&lt;K<sup>+<\/sup>&lt;Rb<sup>+<\/sup>&lt;Cs<sup>+<\/sup>\u306e\u9806\u3067\u5f37\u304f\u4fdd\u6301\u3055\u308c\u307e\u3059\u3002<\/strong>\u30a4\u30aa\u30f3\u4ea4\u63db\u5206\u96e2\u3067\u306f\u3001\u3044\u304f\u3064\u304b\u306e\u4f5c\u7528\u304c\u540c\u6642\u306b\u50cd\u304d\u307e\u3059\u304c\u3001\u3042\u308b\u7a0b\u5ea6\u306f\u5206\u96e2\u306e\u63a8\u6e2c\u304c\u53ef\u80fd\u3067\u3001\u30b3\u30f3\u30d4\u30e5\u30fc\u30bf\u30fc\u3067\u30b7\u30df\u30e5\u30ec\u30fc\u30b7\u30e7\u30f3\u3067\u304d\u307e\u3059\u3002\u3057\u304b\u3057\u3001<strong>\u5b9f\u969b\u306f\u7528\u3044\u308b\u30ab\u30e9\u30e0\u3001\u6eb6\u96e2\u6db2\u3001\u6e29\u5ea6\u306a\u3069\u306b\u3088\u308a\u5206\u96e2\u306f\u5927\u304d\u304f\u5909\u308f\u308a\u307e\u3059\u3002<\/strong><\/p>\n<div id=\"attachment_1627\" style=\"width: 522px\" class=\"wp-caption aligncenter\"><a href=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/principle-and-factors-of-ion-exchange-separation-fig2.png\" rel=\"attachment wp-att-1627\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-1627\" class=\"size-full wp-image-1627\" src=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/principle-and-factors-of-ion-exchange-separation-fig2.png\" alt=\"principle-and-factors-of-ion-exchange-separation-fig2\" width=\"512\" height=\"793\" \/><\/a><p id=\"caption-attachment-1627\" class=\"wp-caption-text\">\u56f32 \u30ab\u30e9\u30e0\u5185\u3067\u306e\u5206\u96e2\u306e\u6a21\u5f0f\u56f3<\/p><\/div>\n<h2>\u30a4\u30aa\u30f3\u4ea4\u63db\u5206\u96e2\u306b\u5f71\u97ff\u3059\u308b4\u3064\u306e\u56e0\u5b50<\/h2>\n<h3>\u6eb6\u96e2\u6db2\u306e\u6fc3\u5ea6\u3068\u7a2e\u985e<\/h3>\n<p>\u9670\u30a4\u30aa\u30f3\u6eb6\u96e2\u6db2\u4e2d\u306e\u70ad\u9178\u30a4\u30aa\u30f3\uff08CO<sub>3<\/sub><sup>2-<\/sup>\uff09\u3084\u6c34\u9178\u5316\u7269\u30a4\u30aa\u30f3\uff08OH<sup>&#8211;<\/sup>\uff09\u3001\u967d\u30a4\u30aa\u30f3\u6eb6\u96e2\u6db2\u4e2d\u306e\u6c34\u7d20\u30a4\u30aa\u30f3\uff08H<sup>+<\/sup>\uff09\u306a\u3069\u3092\u6eb6\u96e2\u5264\u30a4\u30aa\u30f3\u3068\u8a00\u3044\u307e\u3059\u3002\u30a4\u30aa\u30f3\u4ea4\u63db\u5206\u96e2\u3067\u306f\u3001\u30a4\u30aa\u30f3\u4ea4\u63db\u57fa\u4e0a\u306b\u304a\u3051\u308b\u6e2c\u5b9a\u30a4\u30aa\u30f3\u3068\u6eb6\u96e2\u5264\u30a4\u30aa\u30f3\u3068\u306e\u7af6\u5408\u306b\u3088\u308a\u5206\u96e2\u304c\u884c\u308f\u308c\u307e\u3059\u3002<strong>\u6eb6\u96e2\u5264\u30a4\u30aa\u30f3\u6fc3\u5ea6\uff08\u6eb6\u96e2\u6db2\u6fc3\u5ea6\uff09\u304c\u4f4e\u304f\u306a\u308b\u3068\u3001\u6e2c\u5b9a\u30a4\u30aa\u30f3\u3068\u6eb6\u96e2\u5264\u30a4\u30aa\u30f3\u3068\u306e\u7af6\u5408\u304c\u5c0f\u3055\u304f\u306a\u308a\u3001\u6e2c\u5b9a\u30a4\u30aa\u30f3\u304c\u30a4\u30aa\u30f3\u4ea4\u63db\u57fa\u306b\u4fdd\u6301\u3055\u308c\u308b\u6642\u9593\u304c\u9577\u304f\u306a\u308b\u305f\u3081\u6eb6\u51fa\u306f\u9045\u304f\u306a\u308a\u307e\u3059<\/strong>\uff08\u56f33\uff09\u3002\u7279\u306b\u591a\u4fa1\u306e\u6e2c\u5b9a\u30a4\u30aa\u30f3\u306f\u30a4\u30aa\u30f3\u4ea4\u63db\u57fa\u306b\u5bfe\u3059\u308b\u89aa\u548c\u6027\u304c\u5f37\u3044\u305f\u3081\u3001\u4fdd\u6301\u6642\u9593\u304c\u6975\u7aef\u306b\u9577\u304f\u306a\u308b\u50be\u5411\u304c\u3042\u308a\u307e\u3059\u3002\u6eb6\u96e2\u6db2\u6fc3\u5ea6\u3068\u4fdd\u6301\u306e\u5927\u304d\u3055\u3092\u793a\u3059\u30ad\u30e3\u30d1\u30b7\u30c6\u30a3\u30fc\u30d5\u30a1\u30af\u30bf\u30fc\u306e\u95a2\u4fc2\uff08\u56f34\uff09\u3092\u898b\u308b\u3068\u3001\u6e2c\u5b9a\u30a4\u30aa\u30f3\u306e\u4fa1\u6570\u304c\u9ad8\u3044\u307b\u3069\u50be\u304d\u304c\u5927\u304d\u304f\u306a\u3063\u3066\u3044\u308b\u3053\u3068\u304c\u308f\u304b\u308a\u307e\u3059\u3002<\/p>\n<div id=\"attachment_1628\" style=\"width: 748px\" class=\"wp-caption aligncenter\"><a href=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/principle-and-factors-of-ion-exchange-separation-fig3.png\" rel=\"attachment wp-att-1628\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-1628\" class=\"size-full wp-image-1628\" src=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/principle-and-factors-of-ion-exchange-separation-fig3.png\" alt=\"principle-and-factors-of-ion-exchange-separation-fig3\" width=\"738\" height=\"368\" \/><\/a><p id=\"caption-attachment-1628\" class=\"wp-caption-text\">\u56f33 \u6eb6\u96e2\u6db2\u6fc3\u5ea6\u306b\u3088\u308b\u6eb6\u51fa\u6642\u9593\u306e\u5909\u5316\u3002\u30ab\u30e9\u30e0\uff1a<a href=\"https:\/\/www.thermofisher.com\/order\/catalog\/product\/062886?ICID=cmd_ic_r04_jp_principle_and_factors_of_ion_exchange_separation_Social_LAB\n\" target=\"_blank\" rel=\"noopener noreferrer\">Dionex&#x2122; IonPac&#x2122; AS19<\/a>\u3001\u6eb6\u96e2\u6db2\uff1aKOH\uff081.0 mL\/min\uff09<\/p><\/div>\n<div id=\"attachment_1629\" style=\"width: 512px\" class=\"wp-caption aligncenter\"><a href=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/principle-and-factors-of-ion-exchange-separation-fig4.png\" rel=\"attachment wp-att-1629\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-1629\" class=\"size-full wp-image-1629\" src=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/principle-and-factors-of-ion-exchange-separation-fig4.png\" alt=\"principle-and-factors-of-ion-exchange-separation-fig4\" width=\"502\" height=\"340\" \/><\/a><p id=\"caption-attachment-1629\" class=\"wp-caption-text\">\u56f34 \u6eb6\u96e2\u6db2\u6fc3\u5ea6\u3068\u30ad\u30e3\u30d1\u30b7\u30c6\u30a3\u30fc\u30d5\u30a1\u30af\u30bf\u30fc\uff08K\u2019\uff09\u306e\u95a2\u4fc2\u3002k\u2019=(tR-t0)\/t0\u3001tR:\u30d4\u30fc\u30af\u306e\u4fdd\u6301\u6642\u9593\u3001t0:\u30a6\u30a9\u30fc\u30bf\u30fc\u30c7\u30a3\u30c3\u30d7\u6eb6\u51fa\u6642\u9593\u3001\u6761\u4ef6\u306f\u56f33\u3068\u540c\u3058<\/p><\/div>\n<p><strong>2 \u4fa1\u306e\u6eb6\u96e2\u5264\u30a4\u30aa\u30f3\u306f\u30011 \u4fa1\u306b\u6bd4\u3079\u3066\u6e2c\u5b9a\u30a4\u30aa\u30f3\u3092\u30a4\u30aa\u30f3\u4ea4\u63db\u57fa\u304b\u3089\u901f\u304f\u8131\u96e2\u3055\u305b\u308b\u3053\u3068\u304c\u3067\u304d\u308b\u305f\u3081\u3001\u6eb6\u51fa\u3092\u901f\u304f\u3067\u304d\u307e\u3059\u3002\u9670\u30a4\u30aa\u30f3\u6eb6\u96e2\u6db2\u306e\u6eb6\u51fa\u529b\u306f\u3001Na<sub>2<\/sub>CO<sub>3<\/sub>&gt;NaHCO<sub>3<\/sub>&gt;NaOH\uff08KOH\uff09\u306e\u9806<\/strong>\u306b\u306a\u308a\u307e\u3059\uff08\u56f35\uff09\u3002<strong>\u967d\u30a4\u30aa\u30f3\u6eb6\u96e2\u6db2\u306e\u6eb6\u51fa\u529b\u306f\u3001H<sub>2<\/sub>SO<sub>4<\/sub>&gt;\u30e1\u30bf\u30f3\u30b9\u30eb\u30db\u30f3\u9178=HCl \u306e\u9806<\/strong>\u306b\u306a\u308a\u307e\u3059\uff08HCl \u306f\u96fb\u89e3\u578b\u30b5\u30d7\u30ec\u30c3\u30b5\u30fc\u3067\u306f\u4f7f\u7528\u3067\u304d\u307e\u305b\u3093\u306e\u3067\u3054\u6ce8\u610f\u304f\u3060\u3055\u3044\uff09\u3002\u307e\u305f\u3001\u6eb6\u96e2\u6db2\u306epH \u3092\u5909\u5316\u3055\u305b\u308b\u3068\u3001\u591a\u6bb5\u968e\u89e3\u96e2\u3057\u3066\u3044\u308b\u30a4\u30aa\u30f3\uff08\u308a\u3093\u9178\u306a\u3069\uff09\u306e\u6eb6\u51fa\u4f4d\u7f6e\u3092\u5927\u304d\u304f\u5909\u3048\u308b\u3053\u3068\u304c\u3067\u304d\u307e\u3059\uff08\u56f36\uff09\u3002<\/p>\n<div id=\"attachment_1630\" style=\"width: 740px\" class=\"wp-caption aligncenter\"><a href=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/principle-and-factors-of-ion-exchange-separation-fig5.png\" rel=\"attachment wp-att-1630\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-1630\" class=\"size-full wp-image-1630\" src=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/principle-and-factors-of-ion-exchange-separation-fig5.png\" alt=\"principle-and-factors-of-ion-exchange-separation-fig5\" width=\"730\" height=\"368\" \/><\/a><p id=\"caption-attachment-1630\" class=\"wp-caption-text\">\u56f35 \u6eb6\u96e2\u6db2\u306e\u7a2e\u985e\u3068\u6eb6\u51fa\u6642\u9593\u306e\u9055\u3044\u3002\u30ab\u30e9\u30e0\uff1a<a href=\"https:\/\/www.thermofisher.com\/order\/catalog\/product\/046034?ICID=cmd_ic_r04_jp_principle_and_factors_of_ion_exchange_separation_Social_LAB\n\" target=\"_blank\" rel=\"noopener noreferrer\">Dionex IonPac AS12A<\/a>\u3001\u6eb6\u96e2\u6db2\uff1a\u54044 mmol\/L\uff081.2 mL\/min\uff09<\/p><\/div>\n<div id=\"attachment_1631\" style=\"width: 478px\" class=\"wp-caption aligncenter\"><a href=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/principle-and-factors-of-ion-exchange-separation-fig6.png\" rel=\"attachment wp-att-1631\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-1631\" class=\"size-full wp-image-1631\" src=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/principle-and-factors-of-ion-exchange-separation-fig6.png\" alt=\"principle-and-factors-of-ion-exchange-separation-fig6\" width=\"468\" height=\"326\" \/><\/a><p id=\"caption-attachment-1631\" class=\"wp-caption-text\">\u56f36 \u6eb6\u96e2\u6db2pH \u3068\u30ad\u30e3\u30d1\u30b7\u30c6\u30a3\u30fc\u30d5\u30a1\u30af\u30bf\u30fc\uff08K\u2019\uff09\u306e\u95a2\u4fc2\u3002\u30ab\u30e9\u30e0\uff1a<a href=\"https:\/\/www.thermofisher.com\/order\/catalog\/product\/064135?ICID=cmd_ic_r04_jp_principle_and_factors_of_ion_exchange_separation_Social_LAB\n\" target=\"_blank\" rel=\"noopener noreferrer\">Dionex IonPac AS22<\/a>\u3001\u6eb6\u96e2\u6db2\uff1a4.6 mmol\/L Na<sub>2<\/sub>CO<sub>3<\/sub>\uff081.2 mL\/min\uff09\u3001NaHCO<sub>3<\/sub>\u3067pH\u8abf\u6574\u3002<\/p><\/div>\n<h3>\u30ab\u30e9\u30e0\u6e29\u5ea6<\/h3>\n<p><strong>\u30ab\u30e9\u30e0\u6e29\u5ea6\u3092\u5909\u5316\u3055\u305b\u308b\u3068\u3001\u5206\u96e2\u5e73\u8861\u3001\u62e1\u6563\u901f\u5ea6\u3001\u89e3\u96e2\u5ea6\u3001\u6eb6\u96e2\u6db2\u306e\u7c98\u6027\u306a\u3069\u306e\u5909\u5316\u306b\u3088\u308a\u3001\u6e2c\u5b9a\u30a4\u30aa\u30f3\u306e\u4fdd\u6301\u6642\u9593\u304c\u5909\u5316\u3057\u307e\u3059\u3002<\/strong>\u6e29\u5ea6\u306e\u5f71\u97ff\u306f\u6e2c\u5b9a\u30a4\u30aa\u30f3\u7a2e\u306b\u3088\u3063\u3066\u7570\u306a\u308a\u3001\u30ab\u30e9\u30e0\u3084\u6eb6\u96e2\u6db2\u306b\u3088\u3063\u3066\u3082\u5909\u308f\u308a\u307e\u3059\u3002<strong>\u4e00\u822c\u7684\u306b\u6e29\u5ea6\u3092\u4e0a\u3052\u308b\u3068\u6eb6\u96e2\u6db2\u306e\u7c98\u6027\u304c\u4e0b\u304c\u308a\u3001\u30a4\u30aa\u30f3\u4ea4\u63db\u57fa\u4e0a\u3067\u306e\u6eb6\u96e2\u5264\u30a4\u30aa\u30f3\u3068\u6e2c\u5b9a\u30a4\u30aa\u30f3\u306e\u4ea4\u63db\u901f\u5ea6\u304c\u901f\u304f\u306a\u308b\u305f\u3081\u6eb6\u51fa\u304c\u901f\u304f\u306a\u308b\u50be\u5411\u304c\u3042\u308a\u307e\u3059\u3002<\/strong>\u4e00\u65b9\u3067\u3001\u786b\u9178\u30a4\u30aa\u30f3\u306e\u3088\u3046\u306b\u6c34\u548c\u3057\u3066\u3044\u308b\u3068\u8003\u3048\u3089\u308c\u308b\u30a4\u30aa\u30f3\u306f\u3001\u6e29\u5ea6\u4e0a\u6607\u306b\u4f34\u3044\u6c34\u548c\u72b6\u614b\u304c\u4e0d\u5b89\u5b9a\u306b\u306a\u308b\u3053\u3068\u3067\u3001\u30a4\u30aa\u30f3\u4ea4\u63db\u57fa\u3078\u306e\u89aa\u548c\u6027\u304c\u5897\u5927\u3057\u3001\u6eb6\u51fa\u304c\u9045\u304f\u306a\u308b\u3068\u8003\u3048\u3089\u308c\u3066\u3044\u307e\u3059\u3002\u56f37\u306b\u30ab\u30e9\u30e0\u3084\u6eb6\u96e2\u6db2\u304c\u7570\u306a\u308b\u6761\u4ef6\u3067\u306e\u3001\u6e29\u5ea6\u3068\u4fdd\u6301\u6642\u9593\u306e\u95a2\u4fc2\u3092\u793a\u3057\u307e\u3059\u30021\u4fa1\u306e\u30a4\u30aa\u30f3\u306b\u5bfe\u3057\u3066\u30012\u30013 \u4fa1\u306e\u786b\u9178\u30a4\u30aa\u30f3\u3084\u308a\u3093\u9178\u30a4\u30aa\u30f3\u306f\u4fdd\u6301\u6642\u9593\u306e\u5909\u5316\u304c\u5927\u304d\u3044\u3053\u3068\u304c\u308f\u304b\u308a\u307e\u3059\u3002\u5909\u5316\u306e\u7a0b\u5ea6\u3082\u3001\u6eb6\u96e2\u6db2\u6761\u4ef6\u306b\u3088\u3063\u3066\u5927\u304d\u304f\u5909\u308f\u308b\u3053\u3068\u304c\u308f\u304b\u308a\u307e\u3059\u3002<\/p>\n<div id=\"attachment_1632\" style=\"width: 794px\" class=\"wp-caption aligncenter\"><a href=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/principle-and-factors-of-ion-exchange-separation-fig7.png\" rel=\"attachment wp-att-1632\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-1632\" class=\"size-full wp-image-1632\" src=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/principle-and-factors-of-ion-exchange-separation-fig7.png\" alt=\"principle-and-factors-of-ion-exchange-separation-fig7\" width=\"784\" height=\"785\" \/><\/a><p id=\"caption-attachment-1632\" class=\"wp-caption-text\">\u56f37 \u6e29\u5ea6\u3068\u9670\u30a4\u30aa\u30f3\u306e\u4fdd\u6301\u6642\u9593\uff08k\u2019; \u30ad\u30e3\u30d1\u30b7\u30c6\u30a3\u30fc\u30d5\u30a1\u30af\u30bf\u30fc\uff09\u306e\u95a2\u4fc2<\/p><\/div>\n<p><strong>\u30ab\u30e9\u30e0\u6e29\u5ea6\u306e\u5909\u5316\u306b\u3088\u308a\u6e2c\u5b9a\u30a4\u30aa\u30f3\u306b\u3088\u3063\u3066\u306f\u4fdd\u6301\u6319\u52d5\u304c\u5909\u308f\u308b\u3053\u3068\u304b\u3089\u3001\u6e29\u5ea6\u3092\u4f7f\u3063\u3066\u5206\u96e2\u72b6\u614b\u3092\u8abf\u7bc0\u3067\u304d\u307e\u3059\u3002<\/strong>\u56f38 \u306b<a href=\"https:\/\/www.thermofisher.com\/order\/catalog\/product\/057574?ICID=cmd_ic_r04_jp_principle_and_factors_of_ion_exchange_separation_Social_LAB\n\" target=\"_blank\" rel=\"noopener noreferrer\">Dionex&#x2122; IonPac&#x2122; CS16\u30ab\u30e9\u30e0<\/a>\u3092\u7528\u3044\u305f\u3068\u304d\u306e\u3001\u967d\u30a4\u30aa\u30f3\u3068\u30a8\u30bf\u30ce\u30fc\u30eb\u30a2\u30df\u30f3\u306e\u5206\u96e2\u4f8b\u3092\u793a\u3057\u307e\u3059\u3002\u3053\u306e\u30ab\u30e9\u30e0\u3067\u306f\u3001\u6e29\u5ea6\u3092\u4e0a\u3052\u308b\u3053\u3068\u306b\u3088\u308a\u3001\u30a2\u30f3\u30e2\u30cb\u30a6\u30e0\u30a4\u30aa\u30f3\u3068\u30e2\u30ce\u30a8\u30bf\u30ce\u30fc\u30eb\u30a2\u30df\u30f3\u3001\u30ab\u30ea\u30a6\u30e0\u30a4\u30aa\u30f3\u3068\u30c8\u30ea\u30a8\u30bf\u30ce\u30fc\u30eb\u30a2\u30df\u30f3\u306e\u5206\u96e2\u3092\u6539\u5584\u3059\u308b\u3053\u3068\u304c\u53ef\u80fd\u3067\u3059\uff08\u6ce8\uff1a\u30ab\u30e9\u30e0\u6e29\u5ea6\u309240\u2103\u4ee5\u4e0a\u306b\u3059\u308b\u5834\u5408\u306f\u3001\u53d6\u6271\u8aac\u660e\u66f8\u3092\u3054\u53c2\u7167\u306e\u4e0a\u30b5\u30d7\u30ec\u30c3\u30b5\u30fc\u306b\u9ad8\u6e29\u306e\u6eb6\u96e2\u6db2\u304c\u5165\u3089\u306a\u3044\u3088\u3046\u306b\u3057\u3066\u304f\u3060\u3055\u3044\uff09\u3002<\/p>\n<div id=\"attachment_1634\" style=\"width: 822px\" class=\"wp-caption aligncenter\"><a href=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/principle-and-factors-of-ion-exchange-separation-fig8.png\" rel=\"attachment wp-att-1634\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-1634\" class=\"size-full wp-image-1634\" src=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/principle-and-factors-of-ion-exchange-separation-fig8.png\" alt=\"principle-and-factors-of-ion-exchange-separation-fig8\" width=\"812\" height=\"424\" \/><\/a><p id=\"caption-attachment-1634\" class=\"wp-caption-text\">\u56f38 \u967d\u30a4\u30aa\u30f3\u3068\u30a8\u30bf\u30ce\u30fc\u30eb\u30a2\u30df\u30f3\u306e\u5206\u96e2\u3002\u30ab\u30e9\u30e0\uff1a<a href=\"https:\/\/www.thermofisher.com\/order\/catalog\/product\/057574?ICID=cmd_ic_r04_jp_principle_and_factors_of_ion_exchange_separation_Social_LAB\n\" target=\"_blank\" rel=\"noopener noreferrer\">Dionex IonPac CS16<\/a>\u3001\u6eb6\u96e2\u6db2\uff1a30 mmol\/L \u30e1\u30bf\u30f3\u30b9\u30eb\u30db\u30f3\u9178\uff081.0 mL\/min\uff09<\/p><\/div>\n<h3>\u30a4\u30aa\u30f3\u4ea4\u63db\u57fa\u306e\u758e\u6c34\u6027<\/h3>\n<p><strong>\u30a4\u30aa\u30f3\u4ea4\u63db\u306f\u3001\u4e3b\u306b\u6e2c\u5b9a\u30a4\u30aa\u30f3\u3068\u6eb6\u96e2\u5264\u30a4\u30aa\u30f3\u306e\u30a4\u30aa\u30f3\u4ea4\u63db\u57fa\u4e0a\u3067\u306e\u9759\u96fb\u7684\u76f8\u4e92\u4f5c\u7528\u306b\u3088\u3063\u3066\u5206\u96e2\u304c\u884c\u308f\u308c\u3066\u3044\u307e\u3059\u304c\u3001\u758e\u6c34\u6027\u76f8\u4e92\u4f5c\u7528\u3082\u5206\u96e2\u306b\u5f71\u97ff\u3092\u4e0e\u3048\u307e\u3059\u3002<\/strong><\/p>\n<p>\u758e\u6c34\u6027\u306f\u3001\u30ab\u30e9\u30e0\u57fa\u6750\u306e\u5f71\u97ff\u3092\u3082\u3063\u3068\u3082\u5f37\u304f\u53d7\u3051\u307e\u3059\u304c\u3001\u57fa\u6750\u304c\u540c\u3058\u3067\u3042\u308c\u3070\u30a4\u30aa\u30f3\u4ea4\u63db\u57fa\u306e\u7a2e\u985e\u3067\u5909\u308f\u308a\u307e\u3059\u3002\u305f\u3068\u3048\u3070\u3001\u30a8\u30c1\u30eb\u30d3\u30cb\u30eb\u30d9\u30f3\u30bc\u30f3\/\u30b8\u30d3\u30cb\u30eb\u30d9\u30f3\u30bc\u30f3\u5171\u91cd\u5408\u4f53\u306e\u57fa\u6750\u306f\u3001\u30e1\u30bf\u30af\u30ea\u30ec\u30fc\u30c8\u7cfb\u3084\u30dd\u30ea\u30d3\u30cb\u30eb\u30a2\u30eb\u30b3\u30fc\u30eb\u7cfb\u3088\u308a\u3082\u975e\u5e38\u306b\u758e\u6c34\u6027\u304c\u9ad8\u3044\u3053\u3068\u304c\u77e5\u3089\u308c\u3066\u3044\u307e\u3059\u3002\u30a4\u30aa\u30f3\u4ea4\u63db\u57fa\u306e\u4f8b\u3067\u306f\u3001\u9670\u30a4\u30aa\u30f3\u4ea4\u63db\u306b\u7528\u3044\u3089\u308c\u308b\u30a2\u30eb\u30ab\u30ce\u30fc\u30eb\u30a2\u30df\u30f3\u306f\u30a2\u30eb\u30ad\u30eb\u30a2\u30df\u30f3\u3088\u308a\u3082\u758e\u6c34\u6027\u304c\u4f4e\u304f\u3001\u5206\u96e2\u306e\u8abf\u6574\u304c\u3057\u3084\u3059\u3044\u3067\u3059\u3002\u57fa\u6750\u81ea\u4f53\u306e\u758e\u6c34\u6027\u304c\u9ad8\u304f\u3066\u3082\u3001\u30a4\u30aa\u30f3\u4ea4\u63db\u57fa\u3092\u5c0e\u5165\u3059\u308b\u524d\u306b\u57fa\u6750\u3092\u30ec\u30a4\u30e4\u30fc\u3067\u8986\u3063\u3066\u758e\u6c34\u6027\u3092\u7de9\u548c\u3059\u308b\u3068\u3044\u3063\u305f\u6280\u8853\u3082\u3042\u308a\u3001\u8fd1\u5e74\u3067\u306f\u758e\u6c34\u6027\u306e\u4f4e\u3044\u30ab\u30e9\u30e0\u304c\u591a\u304f\u7528\u3044\u3089\u308c\u3066\u3044\u308b\u3088\u3046\u3067\u3059\u3002<\/p>\n<p>\u758e\u6c34\u6027\u304c\u6bd4\u8f03\u7684\u9ad8\u3044\u30a4\u30aa\u30f3\u6210\u5206\uff08\u30e8\u30a6\u5316\u7269\u30a4\u30aa\u30f3\u3001\u30c1\u30aa\u30b7\u30a2\u30f3\u30a4\u30aa\u30f3\u3001\u904e\u5869\u7d20\u9178\u30a4\u30aa\u30f3\u306a\u3069\uff09\u306f\u4fdd\u6301\u6642\u9593\u3082\u9577\u304f\u3001\u30c6\u30fc\u30ea\u30f3\u30b0\u6c17\u5473\u306e\u30d4\u30fc\u30af\u3067\u3059\u304c\u3001\u758e\u6c34\u6027\u306e\u4f4e\u3044\u30ab\u30e9\u30e0\u3092\u7528\u3044\u308b\u3068\u758e\u6c34\u6027\u76f8\u4e92\u4f5c\u7528\u304c\u5c0f\u3055\u304f\u306a\u308b\u305f\u3081\u3001\u4fdd\u6301\u6642\u9593\u306e\u77ed\u7e2e\u3084\u30d4\u30fc\u30af\u5f62\u72b6\u306e\u6539\u5584\u304c\u884c\u3048\u307e\u3059\uff08\u56f39\uff09\u3002<\/p>\n<div id=\"attachment_1635\" style=\"width: 774px\" class=\"wp-caption aligncenter\"><a href=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/principle-and-factors-of-ion-exchange-separation-fig9.png\" rel=\"attachment wp-att-1635\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-1635\" class=\"size-full wp-image-1635\" src=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/principle-and-factors-of-ion-exchange-separation-fig9.png\" alt=\"principle-and-factors-of-ion-exchange-separation-fig9\" width=\"764\" height=\"532\" \/><\/a><p id=\"caption-attachment-1635\" class=\"wp-caption-text\">\u56f39 \u30ab\u30e9\u30e0\u306e\u758e\u6c34\u6027\u3068\u5206\u96e2\u306e\u9055\u3044<\/p><\/div>\n<p><strong>\u6eb6\u96e2\u6db2\u306e\u758e\u6c34\u6027\u3092\u5909\u5316\u3055\u305b\u308b\u3053\u3068\u306b\u3088\u3063\u3066\u3082\u5206\u96e2\u3092\u8abf\u6574\u3067\u304d\u307e\u3059\u3002\u6eb6\u96e2\u6db2\u306e\u758e\u6c34\u6027\u306f\u30a2\u30bb\u30c8\u30cb\u30c8\u30ea\u30eb\u306a\u3069\u306e\u6709\u6a5f\u6eb6\u5a92\u3092\u6dfb\u52a0\u3059\u308b\u3053\u3068\u306b\u3088\u3063\u3066\u5909\u3048\u307e\u3059\u3002<\/strong>\u56f310 \u306f\u3001\u6eb6\u96e2\u6db2\u306b\u6dfb\u52a0\u3057\u305f\u30a2\u30bb\u30c8\u30cb\u30c8\u30ea\u30eb\u306e\u6fc3\u5ea6\u306b\u3088\u308b\u3001\u4e00\u822c\u7684\u306a\u9670\u30a4\u30aa\u30f3\u306e\u30ad\u30e3\u30d1\u30b7\u30c6\u30a3\u30fc\u30d5\u30a1\u30af\u30bf\u30fc\uff08k\u2019\uff09\u306e\u5909\u5316\u3092\u793a\u3057\u305f\u3082\u306e\u3067\u3059\u3002\u30a2\u30bb\u30c8\u30cb\u30c8\u30ea\u30eb\u306e\u6fc3\u5ea6\u306e\u5897\u52a0\u306b\u3088\u308a\u3001\u81ed\u5316\u7269\u30a4\u30aa\u30f3\u3001\u785d\u9178\u30a4\u30aa\u30f3\u3067\u4fdd\u6301\u6642\u9593\u306e\u77ed\u7e2e\u304c\u898b\u3089\u308c\u3001\u308a\u3093\u9178\u304a\u3088\u3073\u786b\u9178\u30a4\u30aa\u30f3\u3067\u4fdd\u6301\u6642\u9593\u306e\u5897\u52a0\u304c\u898b\u3089\u308c\u307e\u3059\u3002\u758e\u6c34\u6027\u304c\u3053\u308c\u3089\u306e\u30a4\u30aa\u30f3\u3088\u308a\u3082\u9ad8\u3044\u6210\u5206\u306b\u3064\u3044\u3066\u306f\u3001\u3055\u3089\u306b\u9855\u8457\u306a\u52b9\u679c\u304c\u3042\u308a\u307e\u3059\u3002\u306a\u304a\u3001\u6eb6\u96e2\u6db2\u3078\u6709\u6a5f\u6eb6\u5a92\u3092\u6dfb\u52a0\u3059\u308b\u65b9\u6cd5\u306b\u3064\u3044\u3066\u306f\u3001\u9069\u7528\u3067\u304d\u306a\u3044\u30ab\u30e9\u30e0\u3084\u3001\u30b5\u30d7\u30ec\u30c3\u30b5\u30fc\u306e\u4f7f\u7528\u30e2\u30fc\u30c9\u306e\u5236\u9650\u304c\u3042\u308a\u307e\u3059\u306e\u3067\u3001\u53d6\u6271\u8aac\u660e\u66f8\u3092\u3054\u78ba\u8a8d\u304f\u3060\u3055\u3044\u3002\u6e2c\u5b9a\u76ee\u7684\u6210\u5206\u306b\u5fdc\u3058\u3066\u3001\u30ab\u30e9\u30e0\u307e\u305f\u306f\u6eb6\u96e2\u6db2\u306e\u758e\u6c34\u6027\u3092\u9078\u629e\uff0f\u8abf\u7bc0\u3059\u308b\u3053\u3068\u3067\u3001\u5206\u96e2\u306e\u6700\u9069\u5316\u3084\u30d4\u30fc\u30af\u5f62\u72b6\u306e\u6539\u5584\u304c\u53ef\u80fd\u3067\u3059\u3002<\/p>\n<div id=\"attachment_1636\" style=\"width: 556px\" class=\"wp-caption aligncenter\"><a href=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/principle-and-factors-of-ion-exchange-separation-fig10.png\" rel=\"attachment wp-att-1636\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-1636\" class=\"size-full wp-image-1636\" src=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/principle-and-factors-of-ion-exchange-separation-fig10.png\" alt=\"principle-and-factors-of-ion-exchange-separation-fig10\" width=\"546\" height=\"578\" \/><\/a><p id=\"caption-attachment-1636\" class=\"wp-caption-text\">\u56f310 \u6709\u6a5f\u6eb6\u5a92\u6dfb\u52a0\u306b\u3088\u308b\u4fdd\u6301\u306e\u5909\u5316\u3002\u30ab\u30e9\u30e0\uff1a<a href=\"https:\/\/www.thermofisher.com\/order\/catalog\/product\/046034?ICID=cmd_ic_r04_jp_principle_and_factors_of_ion_exchange_separation_Social_LAB\n\" target=\"_blank\" rel=\"noopener noreferrer\">Dionex&#x2122; IonPac&#x2122; AS12A<\/a>\u3001\u6eb6\u96e2\u6db2\uff1a 2.7 mmol\/L Na<sub>2<\/sub>CO<sub>3<\/sub>\u30010.3 mmol\/L NaHCO<sub>3<\/sub>\u3001\u30a2\u30bb\u30c8\u30cb\u30c8\u30ea\u30eb\u3001\u6d41\u91cf\uff1a 1.2 mL\/min<\/p><\/div>\n<h3>\u6eb6\u96e2\u6db2\u306e\u6d41\u91cf<\/h3>\n<p><strong>\u6eb6\u96e2\u6db2\u306e\u6d41\u91cf\u3092\u5909\u3048\u308b\u3068\u3001\u6eb6\u51fa\u6642\u9593\u306f\u4e21\u5bfe\u6570\u30b0\u30e9\u30d5\u306b\u304a\u3044\u3066\u76f4\u7dda\u7684\u306b\u5909\u5316\u3057\u307e\u3059\u3002\u3053\u306e\u3068\u304d\u3001\u30d4\u30fc\u30af\u306e\u6eb6\u51fa\u9806\u5e8f\u306f\u5909\u308f\u308a\u307e\u305b\u3093\u3002\u3064\u307e\u308a\u3001\u6eb6\u96e2\u6db2\u6d41\u91cf\u306e\u5909\u5316\u3067\u306f\u5206\u96e2\u306e\u6539\u5584\u306f\u3042\u307e\u308a\u671f\u5f85\u3067\u304d\u307e\u305b\u3093\u3002<\/strong>\u56f311 \u306b\u793a\u3057\u305f\u6d41\u91cf2.0 mL\/min\uff08A\uff09\u30010.5 mL\/min\uff08B\uff09\u306e\u3068\u304d\u306e\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30e0\u3067\u3001\u6d41\u91cf\u306e\u5c11\u306a\u3044\uff08B\uff09\u306e\u5206\u96e2\u304c\u4e00\u898b\u826f\u3044\u3088\u3046\u3067\u3059\u304c\u3001\uff08A\uff09\u306e\u6642\u9593\u8ef8\u3092\u5f15\u304d\u4f38\u3070\u3059\u3068\uff08B\uff09\u306e\u5206\u96e2\u3068\u3042\u307e\u308a\u5909\u308f\u3089\u306a\u3044\u3053\u3068\u304c\u308f\u304b\u308a\u307e\u3059\u3002<\/p>\n<div id=\"attachment_1637\" style=\"width: 770px\" class=\"wp-caption aligncenter\"><a href=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/principle-and-factors-of-ion-exchange-separation-fig11.png\" rel=\"attachment wp-att-1637\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-1637\" class=\"size-full wp-image-1637\" src=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/principle-and-factors-of-ion-exchange-separation-fig11.png\" alt=\"principle-and-factors-of-ion-exchange-separation-fig11\" width=\"760\" height=\"660\" \/><\/a><p id=\"caption-attachment-1637\" class=\"wp-caption-text\">\u56f311 \u6d41\u91cf\u304c\u7570\u306a\u308b\u3068\u304d\u306e\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30e0\u306e\u9055\u3044<\/p><\/div>\n<p><strong>\u4e00\u65b9\u3067\u3001\u6d41\u91cf\u3092\u5c11\u306a\u304f\u3059\u308b\u3068\u6e2c\u5b9a\u30a4\u30aa\u30f3\u304c\u96fb\u6c17\u4f1d\u5c0e\u5ea6\u30bb\u30eb\u5185\u3092\u3086\u3063\u304f\u308a\u901a\u904e\u3059\u308b\u305f\u3081\u3001\u30d4\u30fc\u30af\u9762\u7a4d\u304c\u5927\u304d\u304f\u306a\u308a\u307e\u3059<\/strong>\uff08\u56f312\uff09\u3002\u4eca\u56de\u7528\u3044\u305f\u6761\u4ef6\u3067\u306f\u3001\u6d41\u91cf\u304c2.0 mL\/min \u306e\u3068\u304d\u306e\u9762\u7a4d\u5024\u306f0.5mL\/min \u306e\u3068\u304d\u306e3.6 \u500d\u3067\u3057\u305f\u3002\u6d41\u91cf\u3092\u5c11\u306a\u304f\u3059\u308b\u3068\u30d4\u30fc\u30af\u5e45\u3082\u5927\u304d\u304f\u306a\u308b\u305f\u3081\u3001\u9762\u7a4d\u5024\u304c\u5927\u304d\u304f\u306a\u3063\u3066\u3082\u611f\u5ea6\u306e\u76ee\u5b89\u3068\u306a\u308b\u30d4\u30fc\u30af\u9ad8\u3055\u306f\u540c\u69d8\u306e\u5272\u5408\u3067\u306f\u5897\u52a0\u3057\u307e\u305b\u3093\u304c\u3001\u305d\u308c\u3067\u3082\u5927\u304d\u304f\u306a\u308a\u307e\u3059\uff08\u56f313\uff09\u3002\u4eca\u56de\u7528\u3044\u305f\u6761\u4ef6\u3067\u306f\u6d41\u91cf0.5 mL\/min \u306e\u3068\u304d\u306f2.0mL\/min \u306e\u3068\u304d\u306e1.2 \u500d\u306e\u30d4\u30fc\u30af\u9ad8\u3055\u3067\u3057\u305f\uff08\u56f311\uff09\u3002\u4fdd\u6301\u6642\u9593\u304c\u554f\u984c\u306b\u306a\u3089\u306a\u3051\u308c\u3070\u3001\u6d41\u91cf\u3092\u5c11\u306a\u304f\u3059\u308b\u3053\u3068\u3067\u611f\u5ea6\u3092\u6539\u5584\u3059\u308b\u3053\u3068\u304c\u53ef\u80fd\u3068\u8a00\u3048\u307e\u3059\u3002\u4e00\u822c\u306b\u3001\u30ab\u30e9\u30e0\u306f\u9069\u5207\u306a\u6d41\u91cf\u7bc4\u56f2\uff08\u307e\u305f\u306f\u5727\u529b\u7bc4\u56f2\uff09\u304c\u6c7a\u307e\u3063\u3066\u304a\u308a\u3001\u305d\u306e\u7bc4\u56f2\u3067\u4f7f\u7528\u3057\u306a\u3051\u308c\u3070\u306a\u308a\u307e\u305b\u3093\u3002\u6d41\u91cf\u3092\u5909\u3048\u308b\u5834\u5408\u306f\u3001\u30ab\u30e9\u30e0\u306e\u53d6\u6271\u8aac\u660e\u66f8\u3092\u3054\u78ba\u8a8d\u304f\u3060\u3055\u3044\u3002<\/p>\n<div id=\"attachment_1638\" style=\"width: 775px\" class=\"wp-caption aligncenter\"><a href=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/principle-and-factors-of-ion-exchange-separation-fig12.png\" rel=\"attachment wp-att-1638\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-1638\" class=\"size-full wp-image-1638\" src=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/principle-and-factors-of-ion-exchange-separation-fig12.png\" alt=\"principle-and-factors-of-ion-exchange-separation-fig12\" width=\"765\" height=\"488\" \/><\/a><p id=\"caption-attachment-1638\" class=\"wp-caption-text\">\u56f312 \u6eb6\u96e2\u6db2\u6d41\u91cf\u3068\u30d4\u30fc\u30af\u9762\u7a4d\u306e\u95a2\u4fc2\u3002\u5206\u6790\u6761\u4ef6\u306f\u56f311\u3068\u540c\u3058\u3001\u6d41\u91cf: 0.3 \uff5e2.0 mL\/min<\/p><\/div>\n<div id=\"attachment_1639\" style=\"width: 768px\" class=\"wp-caption aligncenter\"><a href=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/principle-and-factors-of-ion-exchange-separation-fig13.png\" rel=\"attachment wp-att-1639\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-1639\" class=\"size-full wp-image-1639\" src=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/principle-and-factors-of-ion-exchange-separation-fig13.png\" alt=\"principle-and-factors-of-ion-exchange-separation-fig13\" width=\"758\" height=\"482\" \/><\/a><p id=\"caption-attachment-1639\" class=\"wp-caption-text\">\u56f313 \u6eb6\u96e2\u6db2\u6d41\u91cf\u3068\u30d4\u30fc\u30af\u9ad8\u3055\u306e\u95a2\u4fc2\u3002\u5206\u6790\u6761\u4ef6\u306f\u56f311\u3068\u540c\u3058\u3001\u6d41\u91cf: 0.3 \uff5e2.0 mL\/min<\/p><\/div>\n<h2>\u3010\u7121\u6599\u30c0\u30a6\u30f3\u30ed\u30fc\u30c9\u3011\u30a4\u30aa\u30f3\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc\u304a\u5f79\u7acb\u3061\u8cc7\u6599\uff08\u57fa\u790e\u7de8\uff09<\/h2>\n<p>\u30a4\u30aa\u30f3\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u3092\u4f7f\u3044\u59cb\u3081\u3088\u3046\u3068\u8003\u3048\u3066\u3044\u308b\u3001\u5206\u96e2\u306e\u539f\u7406\u3084\u5206\u6790\u6642\u306e\u30dd\u30a4\u30f3\u30c8\u3092\u898b\u76f4\u3057\u305f\u3044\u3001\u30bd\u30d5\u30c8\u30a6\u30a7\u30a2\u306e\u6a5f\u80fd\u3092\u4f7f\u3044\u3053\u306a\u3057\u305f\u3044\u3001\u5177\u4f53\u7684\u306a\u5206\u6790\u4e8b\u4f8b\u3092\u77e5\u308a\u305f\u3044\u306a\u3069\u3002\u696d\u52d9\u306b\u3059\u3050\u306b\u5f79\u7acb\u3064\u30ce\u30a6\u30cf\u30a6\u304c\u8a70\u307e\u3063\u305f\u8cc7\u6599\u3092\u305c\u3072\u3001\u3054\u6d3b\u7528\u304f\u3060\u3055\u3044\u3002<\/p>\n<p><a class=\"btn btn-red\" href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/industrial\/chromatography\/ion-chromatography-ic\/dl-doc-basic.html?ICID=cmd_ic_r04_jp_principle_and_factors_of_ion_exchange_separation_Social_LAB\n\" target=\"_blank\" rel=\"noopener noreferrer\">\u7121\u6599\u30c0\u30a6\u30f3\u30ed\u30fc\u30c9\u306f\u3053\u3061\u3089<\/a><\/p>\n<h2>\u3010\u7121\u6599\u3011 e-learning \u30a4\u30aa\u30f3\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc\u57fa\u790e\u77e5\u8b58<\/h2>\n<p>\u30a4\u30aa\u30f3\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc\u306b\u3064\u3044\u3066\u3001\u3088\u308a\u6df1\u304f\u5b66\u3073\u305f\u3044\u65b9\u306f\u3001e-learning(\u30aa\u30f3\u30e9\u30a4\u30f3\u30bb\u30df\u30ca\u30fc)\u3092\u3054\u5229\u7528\u304f\u3060\u3055\u3044\u3002<\/p>\n<p>\u5206\u96e2\u3084\u691c\u51fa\u6cd5\u306a\u3069\u306e\u539f\u7406\u3092\u4e2d\u5fc3\u3068\u3057\u305f\u57fa\u790e\u306e\u89e3\u8aac\u3084\u3001\u5b9f\u969b\u306e\u5206\u6790\u6642\u306b\u6ce8\u610f\u3059\u308b\u30dd\u30a4\u30f3\u30c8\u307e\u3067\u3001\u696d\u52d9\u306b\u5f79\u7acb\u3064\u30d2\u30f3\u30c8\u304c\u5b66\u3079\u307e\u3059\u3002<\/p>\n<p><a class=\"btn btn-red\" href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/technical-resources\/e-learnings\/ic-dl.html?ICID=cmd_ic_r04_jp_principle_and_factors_of_ion_exchange_separation_Social_LAB\n\" target=\"_blank\" rel=\"noopener noreferrer\">\u8996\u8074\u306e\u304a\u7533\u3057\u8fbc\u307f\u306f\u3053\u3061\u3089<\/a><\/p>\n<p>&nbsp;<\/p>\n<p>\u7814\u7a76\u7528\u306b\u306e\u307f\u4f7f\u7528\u3067\u304d\u307e\u3059\u3002\u8a3a\u65ad\u7528\u306b\u306f\u4f7f\u7528\u3044\u305f\u3060\u3051\u307e\u305b\u3093\u3002<\/p>\n","protected":false},"excerpt":{"rendered":"<p>\u30a4\u30aa\u30f3\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc\u306e\u5206\u96e2\u6cd5\u3068\u3057\u3066\u4e3b\u306b\u30a4\u30aa\u30f3\u4ea4\u63db\u304c\u7528\u3044\u3089\u308c\u3066\u3044\u307e\u3059\u304c\u3001\u539f\u7406\u304c\u308f\u304b\u308b\u3068\u6e2c\u5b9a\u76ee\u7684\u306b\u5408\u3063\u305f\u5206\u96e2\u306e\u8abf\u7bc0\u3084\u30ab\u30e9\u30e0\u306e\u9078\u629e\u306b\u5f79\u7acb\u3061\u307e\u3059\u3002\u4eca\u56de\u306f\u3001\u30a4\u30aa\u30f3\u4ea4\u63db\u5206\u96e2\u306e\u539f\u7406\u306e\u8aac\u660e\u3068\u30a4\u30aa\u30f3\u4ea4\u63db\u5206\u96e2\u306b\u5f71\u97ff\u3059\u308b4\u3064\u306e\u56e0\u5b50\u3092\u3054\u7d39\u4ecb\u3057\u307e\u3059\u3002<\/p>\n","protected":false},"author":988,"featured_media":2919,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_monsterinsights_skip_tracking":false,"_genesis_hide_title":false,"_genesis_hide_breadcrumbs":false,"_genesis_hide_singular_image":false,"_genesis_hide_footer_widgets":false,"_genesis_custom_body_class":"","_genesis_custom_post_class":"","_genesis_layout":"","_jetpack_newsletter_access":"","_jetpack_dont_email_post_to_subs":false,"_jetpack_newsletter_tier_id":0,"_jetpack_memberships_contains_paywalled_content":false,"_jetpack_hide_featured_image":false,"_jetpack_featured_image_duplicate_dismissed":0,"_jetpack_feature_clip_id":0,"_jetpack_memberships_contains_paid_content":false,"footnotes":"","jetpack_post_was_ever_published":false},"categories":[157],"tags":[52],"division":[],"class_list":["post-554","post","type-post","status-publish","format-standard","has-post-thumbnail","category-analysis","tag-ion-chromatography","entry"],"_selected_authors":"","_selected_reviewers":"","acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v28.9 (Yoast SEO v28.9) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>\u30a4\u30aa\u30f3\u4ea4\u63db\u5206\u96e2\u306e\u539f\u7406\u3068\u5206\u96e2\u306b\u5f71\u97ff\u3059\u308b4\u3064\u306e\u56e0\u5b50\u3068\u306f\uff1f - Learning at the Bench<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/principle-and-factors-of-ion-exchange-separation\/\" \/>\n<meta property=\"og:locale\" content=\"ja_JP\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"\u30a4\u30aa\u30f3\u4ea4\u63db\u5206\u96e2\u306e\u539f\u7406\u3068\u5206\u96e2\u306b\u5f71\u97ff\u3059\u308b4\u3064\u306e\u56e0\u5b50\u3068\u306f\uff1f\" \/>\n<meta property=\"og:description\" content=\"\u30a4\u30aa\u30f3\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc\u306e\u5206\u96e2\u6cd5\u3068\u3057\u3066\u4e3b\u306b\u30a4\u30aa\u30f3\u4ea4\u63db\u304c\u7528\u3044\u3089\u308c\u3066\u3044\u307e\u3059\u304c\u3001\u539f\u7406\u304c\u308f\u304b\u308b\u3068\u6e2c\u5b9a\u76ee\u7684\u306b\u5408\u3063\u305f\u5206\u96e2\u306e\u8abf\u7bc0\u3084\u30ab\u30e9\u30e0\u306e\u9078\u629e\u306b\u5f79\u7acb\u3061\u307e\u3059\u3002\u4eca\u56de\u306f\u3001\u30a4\u30aa\u30f3\u4ea4\u63db\u5206\u96e2\u306e\u539f\u7406\u306e\u8aac\u660e\u3068\u30a4\u30aa\u30f3\u4ea4\u63db\u5206\u96e2\u306b\u5f71\u97ff\u3059\u308b4\u3064\u306e\u56e0\u5b50\u3092\u3054\u7d39\u4ecb\u3057\u307e\u3059\u3002\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/principle-and-factors-of-ion-exchange-separation\/\" \/>\n<meta property=\"og:site_name\" content=\"Learning at the Bench\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/ThermoFisherJapan\" \/>\n<meta property=\"article:published_time\" content=\"2017-01-19T00:00:00+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2023-08-17T06:09:33+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/principle-and-factors-of-ion-exchange-separation-title.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"1200\" \/>\n\t<meta property=\"og:image:height\" content=\"629\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"LATB Staff\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:creator\" content=\"@ThermoFisherJP\" \/>\n<meta name=\"twitter:site\" content=\"@ThermoFisherJP\" \/>\n<meta name=\"twitter:label1\" content=\"\u57f7\u7b46\u8005\" \/>\n\t<meta name=\"twitter:data1\" content=\"LATB Staff\" \/>\n\t<meta name=\"twitter:label2\" content=\"\u63a8\u5b9a\u8aad\u307f\u53d6\u308a\u6642\u9593\" \/>\n\t<meta name=\"twitter:data2\" content=\"17\u5206\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/principle-and-factors-of-ion-exchange-separation\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/principle-and-factors-of-ion-exchange-separation\\\/\"},\"author\":{\"name\":\"LATB Staff\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#\\\/schema\\\/person\\\/201e6a5abb838fa34e8ff0174b015d36\"},\"headline\":\"\u30a4\u30aa\u30f3\u4ea4\u63db\u5206\u96e2\u306e\u539f\u7406\u3068\u5206\u96e2\u306b\u5f71\u97ff\u3059\u308b4\u3064\u306e\u56e0\u5b50\u3068\u306f\uff1f\",\"datePublished\":\"2017-01-19T00:00:00+00:00\",\"dateModified\":\"2023-08-17T06:09:33+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/principle-and-factors-of-ion-exchange-separation\\\/\"},\"wordCount\":238,\"commentCount\":0,\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/principle-and-factors-of-ion-exchange-separation\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2019\\\/07\\\/principle-and-factors-of-ion-exchange-separation-title.jpg\",\"keywords\":[\"\u30a4\u30aa\u30f3\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc\"],\"articleSection\":[\"\u5206\u6790\u30fb\u6e2c\u5b9a\u95a2\u9023\"],\"inLanguage\":\"ja\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/principle-and-factors-of-ion-exchange-separation\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/principle-and-factors-of-ion-exchange-separation\\\/\",\"url\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/principle-and-factors-of-ion-exchange-separation\\\/\",\"name\":\"\u30a4\u30aa\u30f3\u4ea4\u63db\u5206\u96e2\u306e\u539f\u7406\u3068\u5206\u96e2\u306b\u5f71\u97ff\u3059\u308b4\u3064\u306e\u56e0\u5b50\u3068\u306f\uff1f - Learning at the Bench\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/principle-and-factors-of-ion-exchange-separation\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/principle-and-factors-of-ion-exchange-separation\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2019\\\/07\\\/principle-and-factors-of-ion-exchange-separation-title.jpg\",\"datePublished\":\"2017-01-19T00:00:00+00:00\",\"dateModified\":\"2023-08-17T06:09:33+00:00\",\"author\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#\\\/schema\\\/person\\\/201e6a5abb838fa34e8ff0174b015d36\"},\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/principle-and-factors-of-ion-exchange-separation\\\/#breadcrumb\"},\"inLanguage\":\"ja\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/principle-and-factors-of-ion-exchange-separation\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"ja\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/principle-and-factors-of-ion-exchange-separation\\\/#primaryimage\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2019\\\/07\\\/principle-and-factors-of-ion-exchange-separation-title.jpg\",\"contentUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2019\\\/07\\\/principle-and-factors-of-ion-exchange-separation-title.jpg\",\"width\":1200,\"height\":629,\"caption\":\"principle-and-factors-of-ion-exchange-separation-title\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/principle-and-factors-of-ion-exchange-separation\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"\u30a4\u30aa\u30f3\u4ea4\u63db\u5206\u96e2\u306e\u539f\u7406\u3068\u5206\u96e2\u306b\u5f71\u97ff\u3059\u308b4\u3064\u306e\u56e0\u5b50\u3068\u306f\uff1f\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#website\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/\",\"name\":\"Learning at the Bench\",\"description\":\"\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"ja\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#\\\/schema\\\/person\\\/201e6a5abb838fa34e8ff0174b015d36\",\"name\":\"LATB Staff\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"ja\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/8803277856c8b753feb4217dff0f9953327452df1a615c3c88b2f9864efb2ddd?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/8803277856c8b753feb4217dff0f9953327452df1a615c3c88b2f9864efb2ddd?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/8803277856c8b753feb4217dff0f9953327452df1a615c3c88b2f9864efb2ddd?s=96&d=mm&r=g\",\"caption\":\"LATB Staff\"},\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/author\\\/latbstaff\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"\u30a4\u30aa\u30f3\u4ea4\u63db\u5206\u96e2\u306e\u539f\u7406\u3068\u5206\u96e2\u306b\u5f71\u97ff\u3059\u308b4\u3064\u306e\u56e0\u5b50\u3068\u306f\uff1f - Learning at the Bench","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/principle-and-factors-of-ion-exchange-separation\/","og_locale":"ja_JP","og_type":"article","og_title":"\u30a4\u30aa\u30f3\u4ea4\u63db\u5206\u96e2\u306e\u539f\u7406\u3068\u5206\u96e2\u306b\u5f71\u97ff\u3059\u308b4\u3064\u306e\u56e0\u5b50\u3068\u306f\uff1f","og_description":"\u30a4\u30aa\u30f3\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc\u306e\u5206\u96e2\u6cd5\u3068\u3057\u3066\u4e3b\u306b\u30a4\u30aa\u30f3\u4ea4\u63db\u304c\u7528\u3044\u3089\u308c\u3066\u3044\u307e\u3059\u304c\u3001\u539f\u7406\u304c\u308f\u304b\u308b\u3068\u6e2c\u5b9a\u76ee\u7684\u306b\u5408\u3063\u305f\u5206\u96e2\u306e\u8abf\u7bc0\u3084\u30ab\u30e9\u30e0\u306e\u9078\u629e\u306b\u5f79\u7acb\u3061\u307e\u3059\u3002\u4eca\u56de\u306f\u3001\u30a4\u30aa\u30f3\u4ea4\u63db\u5206\u96e2\u306e\u539f\u7406\u306e\u8aac\u660e\u3068\u30a4\u30aa\u30f3\u4ea4\u63db\u5206\u96e2\u306b\u5f71\u97ff\u3059\u308b4\u3064\u306e\u56e0\u5b50\u3092\u3054\u7d39\u4ecb\u3057\u307e\u3059\u3002","og_url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/principle-and-factors-of-ion-exchange-separation\/","og_site_name":"Learning at the Bench","article_publisher":"https:\/\/www.facebook.com\/ThermoFisherJapan","article_published_time":"2017-01-19T00:00:00+00:00","article_modified_time":"2023-08-17T06:09:33+00:00","og_image":[{"width":1200,"height":629,"url":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/principle-and-factors-of-ion-exchange-separation-title.jpg","type":"image\/jpeg"}],"author":"LATB Staff","twitter_card":"summary_large_image","twitter_creator":"@ThermoFisherJP","twitter_site":"@ThermoFisherJP","twitter_misc":{"\u57f7\u7b46\u8005":"LATB Staff","\u63a8\u5b9a\u8aad\u307f\u53d6\u308a\u6642\u9593":"17\u5206"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/principle-and-factors-of-ion-exchange-separation\/#article","isPartOf":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/principle-and-factors-of-ion-exchange-separation\/"},"author":{"name":"LATB Staff","@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#\/schema\/person\/201e6a5abb838fa34e8ff0174b015d36"},"headline":"\u30a4\u30aa\u30f3\u4ea4\u63db\u5206\u96e2\u306e\u539f\u7406\u3068\u5206\u96e2\u306b\u5f71\u97ff\u3059\u308b4\u3064\u306e\u56e0\u5b50\u3068\u306f\uff1f","datePublished":"2017-01-19T00:00:00+00:00","dateModified":"2023-08-17T06:09:33+00:00","mainEntityOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/principle-and-factors-of-ion-exchange-separation\/"},"wordCount":238,"commentCount":0,"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/principle-and-factors-of-ion-exchange-separation\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/principle-and-factors-of-ion-exchange-separation-title.jpg","keywords":["\u30a4\u30aa\u30f3\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc"],"articleSection":["\u5206\u6790\u30fb\u6e2c\u5b9a\u95a2\u9023"],"inLanguage":"ja","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/principle-and-factors-of-ion-exchange-separation\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/principle-and-factors-of-ion-exchange-separation\/","url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/principle-and-factors-of-ion-exchange-separation\/","name":"\u30a4\u30aa\u30f3\u4ea4\u63db\u5206\u96e2\u306e\u539f\u7406\u3068\u5206\u96e2\u306b\u5f71\u97ff\u3059\u308b4\u3064\u306e\u56e0\u5b50\u3068\u306f\uff1f - Learning at the Bench","isPartOf":{"@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/principle-and-factors-of-ion-exchange-separation\/#primaryimage"},"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/principle-and-factors-of-ion-exchange-separation\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/principle-and-factors-of-ion-exchange-separation-title.jpg","datePublished":"2017-01-19T00:00:00+00:00","dateModified":"2023-08-17T06:09:33+00:00","author":{"@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#\/schema\/person\/201e6a5abb838fa34e8ff0174b015d36"},"breadcrumb":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/principle-and-factors-of-ion-exchange-separation\/#breadcrumb"},"inLanguage":"ja","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/principle-and-factors-of-ion-exchange-separation\/"]}]},{"@type":"ImageObject","inLanguage":"ja","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/principle-and-factors-of-ion-exchange-separation\/#primaryimage","url":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/principle-and-factors-of-ion-exchange-separation-title.jpg","contentUrl":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/principle-and-factors-of-ion-exchange-separation-title.jpg","width":1200,"height":629,"caption":"principle-and-factors-of-ion-exchange-separation-title"},{"@type":"BreadcrumbList","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/principle-and-factors-of-ion-exchange-separation\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/"},{"@type":"ListItem","position":2,"name":"\u30a4\u30aa\u30f3\u4ea4\u63db\u5206\u96e2\u306e\u539f\u7406\u3068\u5206\u96e2\u306b\u5f71\u97ff\u3059\u308b4\u3064\u306e\u56e0\u5b50\u3068\u306f\uff1f"}]},{"@type":"WebSite","@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#website","url":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/","name":"Learning at the Bench","description":"","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"ja"},{"@type":"Person","@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#\/schema\/person\/201e6a5abb838fa34e8ff0174b015d36","name":"LATB Staff","image":{"@type":"ImageObject","inLanguage":"ja","@id":"https:\/\/secure.gravatar.com\/avatar\/8803277856c8b753feb4217dff0f9953327452df1a615c3c88b2f9864efb2ddd?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/8803277856c8b753feb4217dff0f9953327452df1a615c3c88b2f9864efb2ddd?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/8803277856c8b753feb4217dff0f9953327452df1a615c3c88b2f9864efb2ddd?s=96&d=mm&r=g","caption":"LATB Staff"},"url":"https:\/\/admin.acceleratingscience.com\/author\/latbstaff\/"}]}},"taxonomy_info":{"category":[{"value":157,"label":"\u5206\u6790\u30fb\u6e2c\u5b9a\u95a2\u9023"}],"post_tag":[{"value":52,"label":"\u30a4\u30aa\u30f3\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc"}]},"featured_image_src_large":["https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/principle-and-factors-of-ion-exchange-separation-title-1024x537.jpg",760,399,true],"author_info":{"display_name":"LATB Staff","author_link":"https:\/\/admin.acceleratingscience.com\/author\/latbstaff\/"},"comment_info":0,"category_info":[{"term_id":157,"name":"\u5206\u6790\u30fb\u6e2c\u5b9a\u95a2\u9023","slug":"analysis","term_group":0,"term_taxonomy_id":157,"taxonomy":"category","description":"","parent":0,"count":107,"filter":"raw","meta":[],"cat_ID":157,"category_count":107,"category_description":"","cat_name":"\u5206\u6790\u30fb\u6e2c\u5b9a\u95a2\u9023","category_nicename":"analysis","category_parent":0}],"tag_info":[{"term_id":52,"name":"\u30a4\u30aa\u30f3\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc","slug":"ion-chromatography","term_group":0,"term_taxonomy_id":52,"taxonomy":"post_tag","description":"","parent":0,"count":12,"filter":"raw","meta":[]}],"jetpack-related-posts":[{"id":25090,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/battery-development-elemental-analysis-csm-26016\/","url_meta":{"origin":554,"position":0},"title":"\u30ea\u30c1\u30a6\u30e0\u30a4\u30aa\u30f3\u96fb\u6c60\u88fd\u9020\uff1a\u4f7f\u7528\u3055\u308c\u308b\u5316\u5b66\u5206\u6790\u6280\u8853","author":"LatB Staff","date":"2026\u5e744\u670820\u65e5","format":false,"excerpt":"\u9ad8\u6027\u80fd\u96fb\u6c60\u306b\u5bfe\u3059\u308b\u9700\u8981\u306e\u6025\u5897\u306f\u3001\u751f\u7523\u306e\u3042\u3089\u3086\u308b\u6bb5\u968e\u306b\u304a\u3051\u308b\u5927\u898f\u6a21\u306a\u6295\u8cc7\u3092\u4fc3\u3057\u3066\u3044\u307e\u3059\u3002\u96fb\u6c60\u7814\u7a76\u304a\u3088\u3073\u2026","rel":"","context":"\u5206\u6790\u30fb\u6e2c\u5b9a\u95a2\u9023","block_context":{"text":"\u5206\u6790\u30fb\u6e2c\u5b9a\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/analysis\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/04\/battery-development-elemental-analysis-csm-26016_eyecatch.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/04\/battery-development-elemental-analysis-csm-26016_eyecatch.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/04\/battery-development-elemental-analysis-csm-26016_eyecatch.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/04\/battery-development-elemental-analysis-csm-26016_eyecatch.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/04\/battery-development-elemental-analysis-csm-26016_eyecatch.jpg?resize=1050%2C600&ssl=1 3x"},"classes":[]},{"id":25362,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/battery-development-ion-chromatography-csm-26020\/","url_meta":{"origin":554,"position":1},"title":"IC-MS\/MS\u3092\u7528\u3044\u305f\u30ea\u30c1\u30a6\u30e0\u30a4\u30aa\u30f3\u96fb\u6c60\u8ca0\u6975\u306e\u52a3\u5316\u89e3\u6790","author":"LatB Staff","date":"2026\u5e746\u670826\u65e5","format":false,"excerpt":"\u539f\u6587\uff08\u82f1\u8a9e\uff09\uff1aExploring Lithium-Ion Battery Anode Degrada\u2026","rel":"","context":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","block_context":{"text":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/mol-bio\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/06\/battery-development-ion-chromatography-csm-26020_eyecatch.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/06\/battery-development-ion-chromatography-csm-26020_eyecatch.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/06\/battery-development-ion-chromatography-csm-26020_eyecatch.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/06\/battery-development-ion-chromatography-csm-26020_eyecatch.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/06\/battery-development-ion-chromatography-csm-26020_eyecatch.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/06\/battery-development-ion-chromatography-csm-26020_eyecatch.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":25673,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/ion-chromatography-semiconductors-cmd-26028\/","url_meta":{"origin":554,"position":2},"title":"\u534a\u5c0e\u4f53\u88fd\u9020\u306b\u304a\u3051\u308bIC\u306e\u5f79\u5272","author":"LatB Staff","date":"2026\u5e7410\u67082\u65e5","format":false,"excerpt":"\u30b9\u30de\u30fc\u30c8\u30d5\u30a9\u30f3\u3084AI\u30b5\u30fc\u30d0\u30fc\u3001\u81ea\u52d5\u8eca\u306a\u3069\u3001\u79c1\u305f\u3061\u306e\u8eab\u306e\u56de\u308a\u306b\u3042\u308b\u96fb\u5b50\u6a5f\u5668\u306e\u591a\u304f\u306f\u534a\u5c0e\u4f53\u306b\u3088\u3063\u3066\u652f\u3048\u3089\u2026","rel":"","context":"\u5206\u6790\u30fb\u6e2c\u5b9a\u95a2\u9023","block_context":{"text":"\u5206\u6790\u30fb\u6e2c\u5b9a\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/analysis\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/09\/ion-chromatography-semiconductors-cmd-26028_eyecatch.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/09\/ion-chromatography-semiconductors-cmd-26028_eyecatch.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/09\/ion-chromatography-semiconductors-cmd-26028_eyecatch.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/09\/ion-chromatography-semiconductors-cmd-26028_eyecatch.jpg?resize=700%2C400&ssl=1 2x"},"classes":[]},{"id":25592,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/ion-chromatography-contaminant-analysis-cmd-26024\/","url_meta":{"origin":554,"position":3},"title":"\u5316\u7ca7\u54c1\u4e2d\u306ePFAS\u5206\u6790\u3068\u306f\uff1f\u7dcf\u6709\u6a5f\u30d5\u30c3\u7d20\uff08TOF\uff09\u6e2c\u5b9a\u306b\u3088\u308b\u30b9\u30af\u30ea\u30fc\u30cb\u30f3\u30b0\u3068\u898f\u5236\u5bfe\u5fdc","author":"LatB Staff","date":"2026\u5e749\u670810\u65e5","format":false,"excerpt":"PFAS\uff08\u6709\u6a5f\u30d5\u30c3\u7d20\u5316\u5408\u7269\uff09\u306f\u3001\u300c\u6c38\u9060\u306e\u5316\u5b66\u7269\u8cea\uff08Forever Chemicals\uff09\u300d\u3068\u3082\u547c\u3070\u308c\u3001\u2026","rel":"","context":"\u5206\u6790\u30fb\u6e2c\u5b9a\u95a2\u9023","block_context":{"text":"\u5206\u6790\u30fb\u6e2c\u5b9a\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/analysis\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/08\/ion-chromatography-contaminant-analysis-cmd-26024_eyecatch.png?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/08\/ion-chromatography-contaminant-analysis-cmd-26024_eyecatch.png?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/08\/ion-chromatography-contaminant-analysis-cmd-26024_eyecatch.png?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/08\/ion-chromatography-contaminant-analysis-cmd-26024_eyecatch.png?resize=700%2C400&ssl=1 2x"},"classes":[]},{"id":24614,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/battery-manufacturing-elemental-analysis-csm-26005\/","url_meta":{"origin":554,"position":4},"title":"\u96fb\u6c60\u30ea\u30b5\u30a4\u30af\u30eb\u306b\u304a\u3051\u308b\u5143\u7d20\u5206\u6790","author":"LatB Staff","date":"2026\u5e741\u670827\u65e5","format":false,"excerpt":"\u81ea\u52d5\u8eca\u306e\u96fb\u52d5\u5316\u3068\u518d\u751f\u53ef\u80fd\u30a8\u30cd\u30eb\u30ae\u30fc\u306e\u8caf\u8535\u80fd\u529b\u306e\u5897\u52a0\u306f\u3001\u3068\u3082\u306b\u96fb\u6c60\u306b\u5bfe\u3059\u308b\u9700\u8981\u306e\u5927\u5e45\u306a\u52a0\u901f\u3092\u3082\u305f\u3089\u3057\u3066\u2026","rel":"","context":"\u5206\u6790\u30fb\u6e2c\u5b9a\u95a2\u9023","block_context":{"text":"\u5206\u6790\u30fb\u6e2c\u5b9a\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/analysis\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/01\/battery-manufacturing-elemental-analysis-csm-26005_eyecatch.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/01\/battery-manufacturing-elemental-analysis-csm-26005_eyecatch.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/01\/battery-manufacturing-elemental-analysis-csm-26005_eyecatch.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/01\/battery-manufacturing-elemental-analysis-csm-26005_eyecatch.jpg?resize=700%2C400&ssl=1 2x"},"classes":[]},{"id":24695,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/environmental-analysis-laboratory-lpd-26008\/","url_meta":{"origin":554,"position":5},"title":"Orion Pro Star pH\uff0fISE\u30e1\u30fc\u30bf\u30fc\u3067\u5b9f\u73fe\u3059\u308b\u30a2\u30f3\u30e2\u30cb\u30a2\u30a4\u30aa\u30f3\u306e\u8fc5\u901f\u30fb\u9ad8\u7cbe\u5ea6\u6e2c\u5b9a\u5165\u9580","author":"LatB Staff","date":"2026\u5e742\u670818\u65e5","format":false,"excerpt":"\u6c34\u8cea\u30fb\u5ec3\u6c34\u51e6\u7406\u306e\u73fe\u5834\u3067\u306f\u3001\u30a2\u30f3\u30e2\u30cb\u30a2\u6fc3\u5ea6\u306e\u7ba1\u7406\u306f\u51e6\u7406\u30d7\u30ed\u30bb\u30b9\u3092\u6b63\u5e38\u306b\u4fdd\u3061\u3001\u6cd5\u898f\u5236\u306b\u9069\u5408\u3059\u308b\u305f\u3081\u306b\u6b20\u304b\u2026","rel":"","context":"\u5206\u6790\u30fb\u6e2c\u5b9a\u95a2\u9023","block_context":{"text":"\u5206\u6790\u30fb\u6e2c\u5b9a\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/analysis\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/01\/environmental-analysis-laboratory-lpd-26008_eyecatch_.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/01\/environmental-analysis-laboratory-lpd-26008_eyecatch_.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/01\/environmental-analysis-laboratory-lpd-26008_eyecatch_.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/01\/environmental-analysis-laboratory-lpd-26008_eyecatch_.jpg?resize=700%2C400&ssl=1 2x"},"classes":[]}],"jetpack_sharing_enabled":true,"amp_enabled":true,"jetpack_featured_media_url":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/principle-and-factors-of-ion-exchange-separation-title.jpg","_links":{"self":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/posts\/554","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/users\/988"}],"replies":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/comments?post=554"}],"version-history":[{"count":0,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/posts\/554\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/media\/2919"}],"wp:attachment":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/media?parent=554"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/categories?post=554"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/tags?post=554"},{"taxonomy":"division","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/division?post=554"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}