{"id":569,"date":"2017-02-02T00:00:00","date_gmt":"2017-02-02T00:00:00","guid":{"rendered":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/guidelines-and-optimizing-for-plasmid-dna-transfection\/"},"modified":"2025-02-26T17:16:28","modified_gmt":"2025-02-26T08:16:28","slug":"guidelines-and-optimizing-for-plasmid-dna-transfection","status":"publish","type":"post","link":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/guidelines-and-optimizing-for-plasmid-dna-transfection\/","title":{"rendered":"\u30d7\u30e9\u30b9\u30df\u30c9DNA\u30c8\u30e9\u30f3\u30b9\u30d5\u30a7\u30af\u30b7\u30e7\u30f3\u306e\u305f\u3081\u306e\u30ac\u30a4\u30c9\u30e9\u30a4\u30f3\u3068\u6700\u9069\u5316\u65b9\u6cd5"},"content":{"rendered":"<p>\u53e4\u5178\u7684\u306a\u30c8\u30e9\u30f3\u30b9\u30d5\u30a7\u30af\u30b7\u30e7\u30f3\u6280\u8853\u306f\u3001\u5f53\u521d\u3001\u30d7\u30e9\u30b9\u30df\u30c9DNA\u3092\u7d30\u80de\u306b\u5c0e\u5165\u3059\u308b\u305f\u3081\u306b\u958b\u767a\u3055\u308c\u307e\u3057\u305f\u304c\u3001\u30d7\u30e9\u30b9\u30df\u30c9DNA\u306f\u30c8\u30e9\u30f3\u30b9\u30d5\u30a7\u30af\u30b7\u30e7\u30f3\u306e\u305f\u3081\u306e\u6700\u3082\u4e00\u822c\u7684\u306a\u30d9\u30af\u30bf\u30fc\u3068\u3057\u3066\u73fe\u5728\u3082\u5b58\u5728\u3057\u3066\u3044\u307e\u3059\u3002\u7d44\u63db\u3048\u907a\u4f1d\u5b50\u304a\u3088\u3073\u8abf\u7bc0\u56e0\u5b50\u304c\u542b\u307e\u308c\u308bDNA\u30d7\u30e9\u30b9\u30df\u30c9\u3092\u7d30\u80de\u306b\u5c0e\u5165\u3059\u308b\u3053\u3068\u306b\u3088\u308a\u3001\u907a\u4f1d\u5b50\u306e\u6a5f\u80fd\u304a\u3088\u3073\u8abf\u7bc0\u3001\u907a\u4f1d\u5b50\u7523\u7269\u306e\u5909\u7570\u89e3\u6790\u304a\u3088\u3073\u751f\u7269\u5b66\u7684\u7279\u5fb4\u3001\u907a\u4f1d\u5b50\u767a\u73fe\u306b\u304a\u3051\u308b\u7d30\u80de\u306e\u30e9\u30a4\u30d5\u30b5\u30a4\u30af\u30eb\u3084\u5065\u5eb7\u3078\u306e\u5f71\u97ff\u306b\u95a2\u3059\u308b\u7814\u7a76\u3084\u3001\u7cbe\u88fd\u3057\u30c0\u30a6\u30f3\u30b9\u30c8\u30ea\u30fc\u30e0\u30a2\u30d7\u30ea\u30b1\u30fc\u30b7\u30e7\u30f3\u306b\u4f7f\u7528\u3059\u308b\u305f\u3081\u306e\u30bf\u30f3\u30d1\u30af\u8cea\u306e\u5927\u91cf\u751f\u7523\u304c\u53ef\u80fd\u3067\u3059\u3002<\/p>\n<p>\u30d9\u30af\u30bf\u30fc\u30b3\u30f3\u30b9\u30c8\u30e9\u30af\u30c8\u306e\u5f62\u614b\uff08\u76f4\u9396\u72b6\u307e\u305f\u306f\u30b9\u30fc\u30d1\u30fc\u30b3\u30a4\u30eb\u72b6\uff09\u304a\u3088\u3073\u30b5\u30a4\u30ba\u3001\u30d7\u30e9\u30b9\u30df\u30c9DNA\u306e\u54c1\u8cea\u3001\u306a\u3089\u3073\u306b\u30d7\u30ed\u30e2\u30fc\u30bf\u30fc\u306e\u9078\u629e\u306f\u3001\u30d7\u30e9\u30b9\u30df\u30c9DNA\u306e\u30c8\u30e9\u30f3\u30b9\u30d5\u30a7\u30af\u30b7\u30e7\u30f3\u52b9\u7387\u306b\u5f71\u97ff\u3092\u4e0e\u3048\u308b\u4e3b\u8981\u306a\u8981\u7d20\u3067\u3059\u3002\u4eca\u56de\u306f\u3001<strong>\u30d7\u30e9\u30b9\u30df\u30c9DNA\u3092\u7528\u3044\u305f\u30c8\u30e9\u30f3\u30b9\u30d5\u30a7\u30af\u30b7\u30e7\u30f3\u306b\u3064\u3044\u3066\u306e\u30ac\u30a4\u30c9\u30e9\u30a4\u30f3\u3068\u30d1\u30e9\u30e1\u30fc\u30bf\u306e\u6700\u9069\u5316\u65b9\u6cd5\u306b\u3064\u3044\u3066<\/strong>\u3054\u7d39\u4ecb\u3057\u307e\u3059\u3002<\/p>\n<h2>\u30d7\u30e9\u30b9\u30df\u30c9DNA\u30c8\u30e9\u30f3\u30b9\u30d5\u30a7\u30af\u30b7\u30e7\u30f3\u306e\u30ac\u30a4\u30c9\u30e9\u30a4\u30f3<\/h2>\n<h3>\u30d9\u30af\u30bf\u30fc\u306b\u95a2\u3059\u308b\u8003\u5bdf<\/h3>\n<p><strong>\u4e00\u904e\u6027\u30c8\u30e9\u30f3\u30b9\u30d5\u30a7\u30af\u30b7\u30e7\u30f3\u306b\u304a\u3044\u3066\u3001\u30b9\u30fc\u30d1\u30fc\u30b3\u30a4\u30ebDNA\u306f\u76f4\u9396\u72b6DNA\u3088\u308a\u3082\u52b9\u7387\u7684\u306b\u53d6\u308a\u8fbc\u307e\u308c\u307e\u3059\u3002<\/strong>\u3053\u308c\u306f\u6050\u3089\u304f\u3001\u74b0\u72b6DNA\u306f\u30a8\u30ad\u30bd\u30cc\u30af\u30ec\u30a2\u30fc\u30bc\u306e\u5f71\u97ff\u3092\u53d7\u3051\u306b\u304f\u3044\u306e\u306b\u5bfe\u3057\u3001\u76f4\u9396\u72b6DNA\u30d5\u30e9\u30b0\u30e1\u30f3\u30c8\u306f\u3053\u306e\u9175\u7d20\u306b\u3088\u3063\u3066\u5373\u5ea7\u306b\u5206\u89e3\u3055\u308c\u308b\u305f\u3081\u3068\u8003\u3048\u3089\u308c\u307e\u3059\uff08Lenachan et al., 2007; von Groll et al., 2006\uff09\u3002\u307e\u305f\u3001\u539f\u5b50\u9593\u529b\u9855\u5fae\u93e1\u89e3\u6790\u3067\u306f\u3001\u74b0\u72b6DNA\u5f62\u614b\u3068\u76f4\u9396\u72b6DNA\u5f62\u614b\u3067\u30ab\u30c1\u30aa\u30f3\u6027\u8102\u8cea\u8a66\u85ac\u3068\u306e\u8907\u5408\u4f53\u5f62\u6210\u30d1\u30bf\u30fc\u30f3\u304c\u975e\u5e38\u306b\u7570\u306a\u308b\u3053\u3068\u304c\u793a\u3055\u308c\u3066\u3044\u307e\u3059\u3002\u3064\u307e\u308a\u3001\u74b0\u72b6DNA\u3067\u306f\u30b3\u30f3\u30d1\u30af\u30c8\u306a\u7403\u72b6\u307e\u305f\u306f\u5186\u67f1\u72b6\u306e\u7e2e\u5408\u7269\u304c\u89b3\u5bdf\u3055\u308c\u308b\u306e\u306b\u5bfe\u3057\u3001\u76f4\u9396\u72b6\u30d7\u30e9\u30b9\u30df\u30c9\u3067\u306f\u4f38\u9577\u3057\u305f\u30d1\u30fc\u30eb\u30cd\u30c3\u30af\u30ec\u30b9\u306e\u3088\u3046\u306a\u69cb\u9020\u304c\u89b3\u5bdf\u3055\u308c\u307e\u3059\u3002\u3088\u308a\u30b3\u30f3\u30d1\u30af\u30c8\u306a\u30b5\u30a4\u30ba\u306e\u74b0\u72b6\u30d7\u30e9\u30b9\u30df\u30c9\u306e\u30ab\u30c1\u30aa\u30f3\u6027\u8102\u8cea\u5a92\u4ecb\u6027\u30c8\u30e9\u30f3\u30b9\u30d5\u30a7\u30af\u30b7\u30e7\u30f3\u306f\u30a8\u30f3\u30c9\u30b5\u30a4\u30c8\u30fc\u30b7\u30b9\u7d4c\u8def\u306b\u4fb5\u5165\u3059\u308b\u53ef\u80fd\u6027\u304c\u3042\u308a\u307e\u3059\u304c\u3001\u4f38\u9577\u3057\u305f\u76f4\u9396\u72b6DNA\u69cb\u9020\u3067\u306f\u672c\u7d4c\u8def\u3078\u306e\u4fb5\u5165\u306f\u305d\u308c\u3068\u306f\u304b\u306a\u308a\u7570\u306a\u308a\u3001\u52b9\u7387\u306f\u4f4e\u3044\u3068\u8003\u3048\u3089\u308c\u307e\u3059\uff08von Groll et al., 2006\uff09\u3002<\/p>\n<p><strong>\u5b89\u5b9a\u30c8\u30e9\u30f3\u30b9\u30d5\u30a7\u30af\u30b7\u30e7\u30f3\u306f\u3001\u76f4\u9396\u72b6DNA\u3092\u4f7f\u7528\u3057\u305f\u5834\u5408\u306b\u5bbf\u4e3b\u30b2\u30ce\u30e0\u3078\u306e\u6700\u9069\u306a\u7d44\u307f\u8fbc\u307f\u304c\u751f\u3058\u308b\u305f\u3081\u3001\u3088\u308a\u52b9\u7387\u7684\u3067\u3059\u3002<\/strong>\u30d5\u30ea\u30fc\u306e\u672b\u7aef\u3092\u6301\u3064\u76f4\u9396\u72b6DNA\u306f\u3001\u3088\u308a\u7d44\u63db\u3048\u304c\u8a98\u5c0e\u3055\u308c\u3001\u5bbf\u4e3b\u67d3\u8272\u4f53\u306b\u7d44\u307f\u8fbc\u307e\u308c\u3084\u3059\u304f\u3001\u7d30\u80de\u3078\u306e\u53d6\u308a\u8fbc\u307f\u52b9\u7387\u304c\u4f4e\u304f\u3066\u3082\u5b89\u5b9a\u306a\u5f62\u8cea\u8ee2\u63db\u4f53\u3092\u751f\u3058\u307e\u3059\u3002<\/p>\n<p>\u30ab\u30c1\u30aa\u30f3\u6027\u8102\u8cea\u5a92\u4ecb\u6027\u30c8\u30e9\u30f3\u30b9\u30d5\u30a7\u30af\u30b7\u30e7\u30f3\u306b\u304a\u3051\u308b\u53d6\u308a\u8fbc\u307f\u52b9\u7387\u304c\u540c\u7a0b\u5ea6\u3067\u3042\u3063\u3066\u3082\u3001<strong>\u30b5\u30a4\u30ba\u304c\u5927\u304d\u3044\u30d7\u30e9\u30b9\u30df\u30c9\u306e\u6838\u3078\u306e\u5c0e\u5165\u52b9\u7387\u306f\u5c0f\u3055\u3044\u30d7\u30e9\u30b9\u30df\u30c9\u3088\u308a\u3082\u4f4e\u4e0b\u3057\u307e\u3059\u3002<\/strong>\u3053\u306e\u5f71\u97ff\u306f\u3001\u8cea\u91cf\u307e\u305f\u306f\u30e2\u30eb\u6fc3\u5ea6\u304c\u7b49\u3057\u304f\u3001\u30b5\u30a4\u30ba\u304c\u7570\u306a\u308b\u30b3\u30f3\u30b9\u30c8\u30e9\u30af\u30c8\u3092\u7528\u3044\u308b\u3068\u89b3\u5bdf\u3055\u308c\u3001\u30d7\u30e9\u30b9\u30df\u30c9\u306e\u6838\u3078\u306e\u5c0e\u5165\u306f\u7d30\u80de\u5185\u79fb\u884c\u901f\u5ea6\u306b\u3088\u3063\u3066\u5236\u9650\u3055\u308c\u3001\u5c0f\u3055\u3044\u30d7\u30e9\u30b9\u30df\u30c9\u306f\u9ad8\u901f\u3067\u7d30\u80de\u8cea\u5185\u306b\u79fb\u884c\u3059\u308b\u3053\u3068\u306b\u3088\u308a\u5206\u89e3\u3055\u308c\u308b\u306e\u3092\u56de\u907f\u3057\u3066\u3044\u308b\u3068\u8003\u3048\u3089\u308c\u307e\u3059\uff08Lukacs, et al., 2000; McLenachan et al., 2007\uff09\u3002<\/p>\n<h3>\u30d7\u30e9\u30b9\u30df\u30c9DNA\u306e\u54c1\u8cea<\/h3>\n<p><strong>\u30d7\u30e9\u30b9\u30df\u30c9DNA\u306e\u7d14\u5ea6\u304a\u3088\u3073\u54c1\u8cea\u306f\u30c8\u30e9\u30f3\u30b9\u30d5\u30a7\u30af\u30b7\u30e7\u30f3\u3092\u6210\u529f\u3055\u305b\u308b\u305f\u3081\u306b\u91cd\u8981\u3067\u3059\u3002\u6700\u9ad8\u306e\u7d50\u679c\u3092\u9054\u6210\u3059\u308b\u305f\u3081\u306b\u306f\u3001\u30d5\u30a7\u30ce\u30fc\u30eb\u3001\u5869\u5316\u30ca\u30c8\u30ea\u30a6\u30e0\u3001\u304a\u3088\u3073\u30a8\u30f3\u30c9\u30c8\u30ad\u30b7\u30f3\u3092\u542b\u307e\u306a\u3044\u6700\u9ad8\u7d14\u5ea6\u306e\u30d7\u30e9\u30b9\u30df\u30c9DNA\u304c\u5fc5\u8981\u3067\u3059\u3002<\/strong>\u593e\u96d1\u7269\u306f\u7d30\u80de\u3092\u6b7b\u6ec5\u3055\u305b\u3001\u5869\u306f\u8102\u8cea\u8907\u5408\u4f53\u306e\u5f62\u6210\u3092\u963b\u5bb3\u3057\u3001\u30c8\u30e9\u30f3\u30b9\u30d5\u30a7\u30af\u30b7\u30e7\u30f3\u52b9\u7387\u3092\u4f4e\u4e0b\u3055\u305b\u307e\u3059\u3002\u30a8\u30f3\u30c9\u30c8\u30ad\u30b7\u30f3\u306f\u30ea\u30dd\u591a\u7cd6\u3068\u3057\u3066\u3082\u77e5\u3089\u308c\u3001\u30d7\u30e9\u30b9\u30df\u30c9\u8abf\u88fd\u306e\u6eb6\u89e3\u30b9\u30c6\u30c3\u30d7\u4e2d\u306b\u653e\u51fa\u3055\u308c\u3001\u591a\u304f\u306e\u5834\u5408\u3001\u30d7\u30e9\u30b9\u30df\u30c9DNA\u3068\u3068\u3082\u306b\u5171\u7cbe\u88fd\u3055\u308c\u307e\u3059\u3002\u3053\u308c\u3089\u306e\u5b58\u5728\u306f\u3001\u521d\u4ee3\u7d30\u80de\u304a\u3088\u3073\u4ed6\u306e\u30bb\u30f3\u30b7\u30c6\u30a3\u30d6\u306a\u7d30\u80de\u306b\u304a\u3051\u308b\u30c8\u30e9\u30f3\u30b9\u30d5\u30a7\u30af\u30b7\u30e7\u30f3\u52b9\u7387\u3092\u660e\u3089\u304b\u306b\u4f4e\u4e0b\u3055\u305b\u307e\u3059\u3002DNA\u306e\u5206\u96e2\u306b\u306f\u3001\u6700\u9ad8\u54c1\u8cea\u306eDNA\u306e\u30c8\u30e9\u30f3\u30b9\u30d5\u30a7\u30af\u30b7\u30e7\u30f3\u3092\u63d0\u4f9b\u3059\u308b\u5f0a\u793e\u306ePureLink\u2122 HiPure Plasmid Kit \uff08Mini\u3001Midi\u3001Maxi\u3001Mega\u3001\u304a\u3088\u3073Giga\uff09\u306e\u4f7f\u7528\u3092\u304a\u85a6\u3081\u3057\u307e\u3059\u3002\u5869\u5316\u30bb\u30b7\u30a6\u30e0\u5bc6\u5ea6\u52fe\u914d\u9060\u5fc3\u6cd5\u3067\u751f\u3058\u305f\u30d0\u30f3\u30c9\u3092\u5206\u96e2\u3059\u308b\u3053\u3068\u306b\u3088\u3063\u3066\u3082\u9ad8\u7d14\u5ea6DNA\u304c\u5f97\u3089\u308c\u307e\u3059\u304c\u3001\u3053\u306e\u30d7\u30ed\u30bb\u30b9\u306f\u6642\u9593\u3092\u6d6a\u8cbb\u3057\u307e\u3059\u3002DNA-\u8102\u8cea\u8907\u5408\u4f53\u3084DNA\u6eb6\u6db2\u3092\u904e\u5270\u306b\u30dc\u30eb\u30c6\u30c3\u30af\u30b9\u3059\u308b\u3053\u3068\u306f\u3001\u7279\u306b\u5927\u304d\u3044\u5206\u5b50\u3092\u90e8\u5206\u7684\u306b\u526a\u65ad\u3059\u308b\u3053\u3068\u306b\u3064\u306a\u304c\u308a\u3001\u305d\u308c\u306b\u3088\u3063\u3066\u30c8\u30e9\u30f3\u30b9\u30d5\u30a7\u30af\u30b7\u30e7\u30f3\u52b9\u7387\u304c\u4f4e\u4e0b\u3057\u307e\u3059\u3002\u5e0c\u91c8\u6e08\u307f\u306eDNA\u306b\u304a\u3051\u308bEDTA\u6fc3\u5ea6\u306f0.3 mM\u3092\u8d85\u3048\u306a\u3044\u3088\u3046\u306b\u3057\u307e\u3059\u3002<\/p>\n<h3>\u907a\u4f1d\u5b50\u7523\u7269\u304a\u3088\u3073\u30d7\u30ed\u30e2\u30fc\u30bf\u30fc<\/h3>\n<p><strong>\u30d7\u30ed\u30e2\u30fc\u30bf\u30fc\u306e\u9078\u629e\u306f\u5bbf\u4e3b\u7d30\u80de\u7cfb\u3001\u904e\u5270\u767a\u73fe\u3055\u305b\u308b\u30bf\u30f3\u30d1\u30af\u8cea\u3001\u304a\u3088\u3073\u5e0c\u671b\u3059\u308b\u767a\u73fe\u30ec\u30d9\u30eb\u306b\u5fdc\u3058\u3066\u884c\u3044\u307e\u3059\u3002<\/strong>\u5e45\u5e83\u3044\u7d30\u80de\u30bf\u30a4\u30d7\u3067\u6700\u3082\u9ad8\u3044\u767a\u73fe\u6d3b\u6027\u3092\u793a\u3059\u5f37\u529b\u306aCMV\uff08\u30b5\u30a4\u30c8\u30e1\u30ac\u30ed\u30a6\u30a4\u30eb\u30b9\uff09\u30d7\u30ed\u30e2\u30fc\u30bf\u30fc\u306f\u591a\u304f\u306e\u7814\u7a76\u8005\u306b\u7528\u3044\u3089\u308c\u3066\u3044\u307e\u3059\u3002\u54fa\u4e73\u985e\u7d30\u80de\u3067\u30bf\u30f3\u30d1\u30af\u8cea\u3092\u9ad8\u767a\u73fe\u3055\u305b\u308b\u305f\u3081\u306e\u4ed6\u306e\u5f37\u529b\u306a\u30d7\u30ed\u30e2\u30fc\u30bf\u30fc\u3068\u3057\u3066EF-1\u03b1\uff08human elongation factor-1\u03b1\uff09\u304c\u3042\u308a\u307e\u3059\u3002\u3057\u304b\u3057\u3001\u5f37\u529b\u904e\u304e\u308b\u30d7\u30ed\u30e2\u30fc\u30bf\u30fc\u3092\u4f7f\u7528\u3059\u308b\u3053\u3068\u306f\u3001\u6bd2\u6027\u907a\u4f1d\u5b50\u767a\u73fe\u306e\u53ef\u80fd\u6027\u3092\u9ad8\u3081\u308b\u3053\u3068\u306b\u306a\u308b\u305f\u3081\u3001\u30d7\u30e9\u30b9\u30df\u30c9DNA\u306e\u4e00\u904e\u6027\u30c8\u30e9\u30f3\u30b9\u30d5\u30a7\u30af\u30b7\u30e7\u30f3\u306b\u304a\u3044\u3066\u554f\u984c\u304c\u3042\u308a\u307e\u3059\u3002\u6bd2\u6027\u907a\u4f1d\u5b50\u7523\u7269\u767a\u73fe\u306e\u53ef\u80fd\u6027\u304c\u3042\u308b\u5834\u5408\u306f\u3001\u5f31\u3044\u30d7\u30ed\u30e2\u30fc\u30bf\u30fc\u306e\u4f7f\u7528\u3092\u304a\u85a6\u3081\u3057\u307e\u3059\u3002<\/p>\n<p>\u6bd2\u6027\u907a\u4f1d\u5b50\u7523\u7269\u306f\u3001\u5b89\u5b9a\u7684\u306b\u30c8\u30e9\u30f3\u30b9\u30d5\u30a7\u30af\u30b7\u30e7\u30f3\u3055\u308c\u305f\u7d30\u80de\u3092\u9078\u629e\u3059\u308b\u969b\u306b\u3082\u554f\u984c\u3067\u3059\u3002\u6297\u751f\u7269\u8cea\u8010\u6027\u907a\u4f1d\u5b50\u3092\u767a\u73fe\u3059\u308b\u7d30\u80de\u306f\u3001\u305d\u306e\u907a\u4f1d\u5b50\u306e\u767a\u73fe\u306b\u3088\u3063\u3066\u5c0e\u5165\u3055\u308c\u305f\u7d30\u80de\u306e\u5065\u5168\u6027\u304c\u640d\u306a\u308f\u308c\u305f\u6642\u306b\u5897\u6b96\u512a\u4f4d\u6027\u3092\u5931\u3044\u307e\u3059\u3002\u305d\u308c\u306b\u3088\u3063\u3066\u3001\u69cb\u6210\u7684\u30d7\u30ed\u30e2\u30fc\u30bf\u30fc\u3092\u7528\u3044\u3066\u5b89\u5b9a\u7684\u306b\u30c8\u30e9\u30f3\u30b9\u30d5\u30a7\u30af\u30b7\u30e7\u30f3\u3055\u308c\u305f\u30af\u30ed\u30fc\u30f3\u3092\u7372\u5f97\u3059\u308b\u3053\u3068\u304c\u4e0d\u53ef\u80fd\u3067\u3059\u3002\u305d\u306e\u3088\u3046\u306a\u30b1\u30fc\u30b9\u3067\u306f\u3001\u907a\u4f1d\u5b50\u767a\u73fe\u306e\u30bf\u30a4\u30df\u30f3\u30b0\u3092\u30b3\u30f3\u30c8\u30ed\u30fc\u30eb\u3059\u308b\u305f\u3081\u306b\u8a98\u5c0e\u6027\u30d7\u30ed\u30e2\u30fc\u30bf\u30fc\u3092\u7528\u3044\u3066\u3001\u5b89\u5b9a\u306a\u5f62\u8cea\u79fb\u5165\u4f53\u3092\u9078\u629e\u3059\u308b\u3053\u3068\u304c\u53ef\u80fd\u3067\u3059\u3002\u8a98\u5c0e\u6027\u30d7\u30ed\u30e2\u30fc\u30bf\u30fc\u306f\u3001\u901a\u5e38\u3001\u6a5f\u80fd\u3059\u308b\u305f\u3081\u306b\u30a4\u30f3\u30c7\u30e5\u30fc\u30b5\u30fc\u5206\u5b50\uff08\u4f8b\uff1a \u91d1\u5c5e\u30a4\u30aa\u30f3\u3001\u4ee3\u8b1d\u7523\u7269\u3001\u307e\u305f\u306f\u30db\u30eb\u30e2\u30f3\uff09\u306e\u5b58\u5728\u3092\u5fc5\u8981\u3068\u3057\u307e\u3059\u304c\u3001\u4e00\u90e8\u306e\u30a4\u30f3\u30c7\u30e5\u30fc\u30b5\u30fc\u5206\u5b50\u306f\u9006\u306e\u65b9\u6cd5\u3001\u3059\u306a\u308f\u3061\u7279\u5b9a\u306e\u5206\u5b50\u306e\u975e\u5b58\u5728\u4e0b\u3067\u907a\u4f1d\u5b50\u767a\u73fe\u306e\u8a98\u5c0e\u304c\u6a5f\u80fd\u3057\u307e\u3059\u3002<\/p>\n<h3>\u30b3\u30f3\u30c8\u30ed\u30fc\u30eb<\/h3>\n<p><strong>\u30c8\u30e9\u30f3\u30b9\u30d5\u30a7\u30af\u30b7\u30e7\u30f3\u306e\u65b9\u6cd5\u306b\u95a2\u308f\u3089\u305a\u3001\u7d30\u80de\u306e\u5065\u5168\u6027\u3092\u78ba\u8a8d\u3059\u308b\u305f\u3081\u306e\u30b3\u30f3\u30c8\u30ed\u30fc\u30eb\u30c8\u30e9\u30f3\u30b9\u30d5\u30a7\u30af\u30b7\u30e7\u30f3\u3092\u5b9f\u65bd\u3059\u308b\u3053\u3068\u3001\u5831\u544a\u3055\u308c\u3066\u3044\u308b\u30a2\u30c3\u30bb\u30a4\u304c\u9069\u5207\u306b\u6a5f\u80fd\u3057\u3066\u3044\u308b\u304b\u3092\u6c7a\u5b9a\u3059\u308b\u3053\u3068\u3001\u304a\u3088\u3073\u3042\u3089\u3086\u308b\u633f\u5165\u95a2\u9023\u306e\u554f\u984c\u306e\u539f\u56e0\u3092\u660e\u3089\u304b\u306b\u3059\u308b\u3053\u3068\u306f\u91cd\u8981\u3067\u3059\u3002<\/strong>\u6700\u9069\u306a\u7d30\u80de\u5897\u6b96\u6761\u4ef6\u3092\u78ba\u8a8d\u3059\u308b\u305f\u3081\u306b\u306f\u3001\u30cd\u30ac\u30c6\u30a3\u30d6\u30b3\u30f3\u30c8\u30ed\u30fc\u30eb\uff08\u975eDNA\u3001\u975e\u30c8\u30e9\u30f3\u30b9\u30d5\u30a7\u30af\u30b7\u30e7\u30f3\u8a66\u85ac\uff09\u3092\u542b\u3080\u5fc5\u8981\u304c\u3042\u308a\u307e\u3059\u3002\u30ec\u30dd\u30fc\u30bf\u30fc\u30a2\u30c3\u30bb\u30a4\u304c\u9069\u5207\u306b\u6a5f\u80fd\u3059\u308b\u3053\u3068\u3092\u78ba\u7acb\u3059\u308b\u305f\u3081\u306b\u306f\u3001\u30dd\u30b8\u30c6\u30a3\u30d6\u30b3\u30f3\u30c8\u30ed\u30fc\u30eb\uff08\u78ba\u7acb\u3055\u308c\u305f\u30c8\u30e9\u30f3\u30b9\u30d5\u30a7\u30af\u30b7\u30e7\u30f3\u6cd5\u3067\u306e\u540c\u6642\u4e26\u884c\u7684\u30c8\u30e9\u30f3\u30b9\u30d5\u30a7\u30af\u30b7\u30e7\u30f3\uff09\u3092\u542b\u3080\u5fc5\u8981\u304c\u3042\u308a\u307e\u3059\u3002\u633f\u5165\u95a2\u9023\u306e\u554f\u984c\u304c\u5b58\u5728\u3059\u308b\u304b\u3092\u6c7a\u5b9a\u3059\u308b\u305f\u3081\u306b\u306f\u3001\u76ee\u7684\u306e\u907a\u4f1d\u5b50\u3092\u542b\u307e\u306a\u3044\u30d7\u30e9\u30b9\u30df\u30c9\u3092\u5c0e\u5165\u3059\u308b\u5fc5\u8981\u304c\u3042\u308a\u307e\u3059\u3002<\/p>\n<h2>\u30d7\u30e9\u30b9\u30df\u30c9DNA\u30c8\u30e9\u30f3\u30b9\u30d5\u30a7\u30af\u30b7\u30e7\u30f3\u306e\u6700\u9069\u5316<\/h2>\n<p><strong>\u3042\u3089\u3086\u308b\u30c8\u30e9\u30f3\u30b9\u30d5\u30a7\u30af\u30b7\u30e7\u30f3\u51e6\u7406\u306b\u304a\u3044\u3066\u4e0d\u53ef\u6b20\u306a\u6700\u521d\u306e\u30b9\u30c6\u30c3\u30d7\u306f\u30c8\u30e9\u30f3\u30b9\u30d5\u30a7\u30af\u30b7\u30e7\u30f3\u6761\u4ef6\u306e\u6700\u9069\u5316\u3067\u3059\u3002<\/strong>\u305d\u308c\u305e\u308c\u306e\u7d30\u80de\u30bf\u30a4\u30d7\u304a\u3088\u3073\u30c8\u30e9\u30f3\u30b9\u30d5\u30a7\u30af\u30b7\u30e7\u30f3\u51e6\u7406\u306b\u306f\u3001\u5916\u6765DNA\u306e\u6700\u9069\u306a\u5c0e\u5165\u306b\u5fc5\u8981\u3068\u3055\u308c\u308b\u7279\u5fb4\u7684\u306a\u4e00\u9023\u306e\u8981\u4ef6\u304c\u3042\u308a\u3001\u3053\u308c\u3089\u306e\u6761\u4ef6\u306f\u4e92\u3044\u306b\u975e\u5e38\u306b\u985e\u4f3c\u3057\u305f\u7d30\u80de\u30bf\u30a4\u30d7\u9593\u3067\u3082\u5927\u304d\u306a\u5909\u52d5\u304c\u3042\u308a\u307e\u3059\u3002<\/p>\n<p><strong>\u30c8\u30e9\u30f3\u30b9\u30d5\u30a7\u30af\u30b7\u30e7\u30f3\u52b9\u7387\u3092\u6700\u9069\u5316\u3059\u308b\u306e\u306b\u6700\u3082\u91cd\u8981\u306a\u4e00\u3064\u306e\u8981\u7d20\u306f\u3001\u7d30\u80de\u30bf\u30a4\u30d7\u306b\u9069\u5207\u306a\u30c8\u30e9\u30f3\u30b9\u30d5\u30a7\u30af\u30b7\u30e7\u30f3\u30d7\u30ed\u30c8\u30b3\u30fc\u30eb\u3092\u9078\u629e\u3059\u308b\u3053\u3068\u3067\u3059\u3002<\/strong>\u4e00\u65e6\u9069\u5207\u306a\u30c8\u30e9\u30f3\u30b9\u30d5\u30a7\u30af\u30b7\u30e7\u30f3\u6cd5\u3092\u9078\u629e\u3057\u305f\u3089\u3001\u69d8\u3005\u306a\u6761\u4ef6\u4e0b\u3067\u30ec\u30dd\u30fc\u30bf\u30fc\u907a\u4f1d\u5b50\u3092\u5c0e\u5165\u3057\u3001\u30ec\u30dd\u30fc\u30bf\u30fc\u907a\u4f1d\u5b50\u7523\u7269\u306e\u30a2\u30c3\u30bb\u30a4\u3059\u308b\u3053\u3068\u306b\u3088\u308a\u30c8\u30e9\u30f3\u30b9\u30d5\u30a7\u30af\u30b7\u30e7\u30f3\u52b9\u7387\u3092\u30e2\u30cb\u30bf\u30fc\u3059\u308b\u3053\u3068\u306b\u3088\u3063\u3066\u4e00\u904e\u6027\u30ec\u30dd\u30fc\u30bf\u30fc\u30a2\u30c3\u30bb\u30a4\u30b7\u30b9\u30c6\u30e0\u3092\u7528\u3044\u3066\u624b\u9806\u3092\u6700\u9069\u5316\u3067\u304d\u307e\u3059\u3002<\/p>\n<p>\u3053\u3053\u3067\u306f\u3001<a href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/life-science\/cell-culture\/transfection\/neon-transfection-system.html?CID=bid_clb_tfx_r04_jp_cp0000_pjt0000_bid00000_0so_blg_op_awa_oc_s00_cc16_Social_LAB\" target=\"_blank\" rel=\"noopener noreferrer\">Neon Transfection System<\/a>\u3092\u7528\u3044\u308b\u30a8\u30ec\u30af\u30c8\u30ed\u30dd\u30ec\u30fc\u30b7\u30e7\u30f3\u3001\u304a\u3088\u3073\u30ab\u30c1\u30aa\u30f3\u6027\u8102\u8cea\u5a92\u4ecb\u6027\u30c8\u30e9\u30f3\u30b9\u30d5\u30a7\u30af\u30b7\u30e7\u30f3\u306e\u6700\u9069\u5316\u306b\u95a2\u3059\u308b\u6709\u76ca\u306a\u60c5\u5831\u304a\u3088\u3073\u4e00\u822c\u7684\u306a\u30ac\u30a4\u30c9\u30e9\u30a4\u30f3\u3092\u3054\u7d39\u4ecb\u3057\u307e\u3059\u3002<\/p>\n<h3>\u30ea\u30f3\u9178\u30ab\u30eb\u30b7\u30a6\u30e0\u5171\u6c88\u6bbf\u6cd5\u306b\u5f71\u97ff\u3059\u308b\u91cd\u8981\u306a\u8981\u7d20<\/h3>\n<p><strong>\u30ea\u30f3\u9178\u30ab\u30eb\u30b7\u30a6\u30e0\u6cd5\u306b\u3088\u308b\u30c8\u30e9\u30f3\u30b9\u30d5\u30a7\u30af\u30b7\u30e7\u30f3\u52b9\u7387\u306b\u5f71\u97ff\u3092\u53ca\u307c\u3059\u4e3b\u8981\u306a\u8981\u7d20\u306f\u3001\u30ea\u30f3\u9178\u30ab\u30eb\u30b7\u30a6\u30e0-DNA\u5171\u6c88\u6bbf\u7269\u4e2d\u306b\u542b\u307e\u308c\u308bDNA\u91cf\u3001\u7d30\u80de\u3092\u5171\u6c88\u6bbf\u7269\u3068\u30a4\u30f3\u30ad\u30e5\u30d9\u30fc\u30b7\u30e7\u30f3\u3059\u308b\u6642\u9593\u306e\u9577\u3055\u3001\u306a\u3089\u3073\u306b\u30b0\u30ea\u30bb\u30ed\u30fc\u30eb\u30b7\u30e7\u30c3\u30af\u307e\u305f\u306fDMSO\u30b7\u30e7\u30c3\u30af\u306e\u4f7f\u7528\u304a\u3088\u3073\u51e6\u7406\u6642\u9593\u306e\u9577\u3055\u3067\u3059\u3002<\/strong><\/p>\n<p>\u30ea\u30f3\u9178\u30ab\u30eb\u30b7\u30a6\u30e0\u6cd5\u306b\u3088\u308b\u30c8\u30e9\u30f3\u30b9\u30d5\u30a7\u30af\u30b7\u30e7\u30f3\u306b\u304a\u3044\u3066\u7528\u3044\u3089\u308c\u308b\u30c8\u30fc\u30bf\u30ebDNA\u91cf\u306f\u3001\u901a\u5e38\u300110 cm\u30c7\u30a3\u30c3\u30b7\u30e51\u679a\u5f53\u305f\u308a\u3001450 \u03bcL\u306e\u6ec5\u83cc\u6c34\u306850 \u03bcL\u306e2.5 M CaCl<sub>2<\/sub>\u4e2d\u306b10\uff5e50 \u03bcg\u3067\u3001\u305d\u306e\u91cf\u306f\u30d7\u30e9\u30b9\u30df\u30c9\u8abf\u88fd\u6cd5\u306a\u3089\u3073\u306b\u7d30\u80de\u304a\u3088\u3073\u57f9\u5730\u306b\u3088\u3063\u3066\u5927\u304d\u304f\u7570\u306a\u308a\u307e\u3059\u300210\uff5e15 \u03bcg\u306eDNA\u309210 cm\u30c7\u30a3\u30c3\u30b7\u30e5\u306b\u6dfb\u52a0\u3059\u308b\u3068\u3001\u4e00\u90e8\u306e\u7d30\u80de\u7cfb\u3067\u306f\u904e\u5ea6\u306e\u7d30\u80de\u6b7b\u304c\u751f\u3058\u3001DNA\u304c\u307b\u3068\u3093\u3069\u53d6\u308a\u8fbc\u307e\u308c\u306a\u304b\u3063\u305f\u308a\u3001\u4ed6\u306e\u7d30\u80de\u7cfb\u3001\u7279\u306b\u521d\u4ee3\u7d30\u80de\u3067\u306f\u306f\u308b\u304b\u306b\u9ad8\u3044DNA\u6fc3\u5ea6\u304c\u5fc5\u8981\u3068\u3055\u308c\u305f\u308a\u307e\u3059\u3002\u3053\u306e\u305f\u3081\u3001\u65b0\u305f\u306b\u30d7\u30e9\u30b9\u30df\u30c9\u3092\u8abf\u88fd\u3059\u308b\u5ea6\u306b\u3001\u307e\u305f\u65b0\u3057\u3044\u7d30\u80de\u7cfb\u3092\u30c8\u30e9\u30f3\u30b9\u30d5\u30a7\u30af\u30b7\u30e7\u30f3\u306b\u7528\u3044\u308b\u5ea6\u306b\u6700\u9069\u306aDNA\u6fc3\u5ea6\u306b\u3064\u3044\u3066\u8a66\u9a13\u3092\u884c\u3046\u5fc5\u8981\u304c\u3042\u308a\u307e\u3059\u3002<\/p>\n<p>\u7d30\u80de\u3092\u5171\u6c88\u6bbf\u7269\u3068\u30a4\u30f3\u30ad\u30e5\u30d9\u30fc\u30b7\u30e7\u30f3\u3059\u308b\u6700\u9069\u306a\u6642\u9593\u306e\u9577\u3055\u3082\u3001\u7d30\u80de\u30bf\u30a4\u30d7\u306b\u3088\u3063\u3066\u7570\u306a\u308a\u307e\u3059\u3002HeLa\u3001NIH 3T3\u3001\u304a\u3088\u3073BALB\/c 3T3\u306a\u3069\u306e\u4e00\u90e8\u306e\u9811\u5f37\u306a\u7d30\u80de\u30bf\u30a4\u30d7\u306f\u3001\u6700\u592716\u6642\u9593\u3067\u5171\u6c88\u6bbf\u7269\u304b\u3089\u5206\u96e2\u3059\u308b\u3053\u3068\u306b\u3088\u308a\u52b9\u7387\u7684\u306b\u30c8\u30e9\u30f3\u30b9\u30d5\u30a7\u30af\u30b7\u30e7\u30f3\u3055\u308c\u307e\u3059\u3002<\/p>\n<p>DNA\u91cf\u3001\u30a4\u30f3\u30ad\u30e5\u30d9\u30fc\u30b7\u30e7\u30f3\u6642\u9593\u3001\u304a\u3088\u3073\u30b0\u30ea\u30bb\u30ed\u30fc\u30eb\u30b7\u30e7\u30c3\u30af\u307e\u305f\u306fDMSO\u30b7\u30e7\u30c3\u30af\u3078\u306e\u66dd\u9732\u3092\u5909\u5316\u3055\u305b\u308b\u30d1\u30a4\u30ed\u30c3\u30c8\u5b9f\u9a13\u3067\u306f\u3001\u30ea\u30f3\u9178\u30ab\u30eb\u30b7\u30a6\u30e0\u6c88\u6bbf\u3078\u306e\u9577\u6642\u9593\u66dd\u9732\u306b\u5bfe\u3059\u308b\u8010\u6027\u3092\u6301\u3064\u7d30\u80de\u30bf\u30a4\u30d7\u3001\u30b0\u30ea\u30bb\u30ed\u30fc\u30eb\u30b7\u30e7\u30c3\u30af\u3092\u4f7f\u7528\u3059\u3079\u304d\u7d30\u80de\u30bf\u30a4\u30d7\u3092\u660e\u3089\u304b\u306b\u3067\u304d\u307e\u3059\u3002\u30d1\u30a4\u30ed\u30c3\u30c8\u5b9f\u9a13\u306e\u7d50\u679c\u304c\u5f97\u3089\u308c\u305f\u3089\u3001\u5b9f\u9a13\u5909\u6570\u3092\u3055\u3089\u306b\u7d30\u304b\u304f\u8abf\u7bc0\u3059\u308b\u3053\u3068\u306b\u3088\u308a\u3055\u3089\u306a\u308b\u6700\u9069\u5316\u3092\u884c\u3048\u307e\u3059\u3002\u4f8b\u3048\u3070\u3001\u4e0b\u8868\u306e\u4f8b\u306e\u3088\u3046\u306b\u7d30\u80de\u30923\u5206\u959310%\u30b0\u30ea\u30bb\u30ed\u30fc\u30eb\u3067\u30b7\u30e7\u30c3\u30af\u51e6\u7406\u3059\u308b\u3068\u3001\u30c8\u30e9\u30f3\u30b9\u30d5\u30a7\u30af\u30b7\u30e7\u30f3\u52b9\u7387\u304c\u5897\u5f37\u3055\u308c\u307e\u3059\u3002\u3042\u308b\u3044\u306f\u3001\u30b0\u30ea\u30bb\u30ed\u30fc\u30eb\u30b7\u30e7\u30c3\u30af\u51e6\u7406\u6642\u9593\u3092\u5909\u5316\u3055\u305b\u305f\u308a\u300110\uff5e20%\u306eDMSO\u30b7\u30e7\u30c3\u30af\u3092\u7528\u3044\u308b\u5b9f\u9a13\u3092\u884c\u3046\u3053\u3068\u3082\u3042\u308a\u307e\u3059\u3002<\/p>\n<table>\n<caption>\u8868 \u30ea\u30f3\u9178\u30ab\u30eb\u30b7\u30a6\u30e0\u5171\u6c88\u6bbf\u6cd5\u306b\u3088\u308b\u30c8\u30e9\u30f3\u30b9\u30d5\u30a7\u30af\u30b7\u30e7\u30f3\u306e\u6700\u9069\u5316\u306e\u305f\u3081\u306e\u30d1\u30a4\u30ed\u30c3\u30c8\u5b9f\u9a13\u306e\u4f8b<\/caption>\n<tbody>\n<tr>\n<td style=\"text-align: center\">\u30c7\u30a3\u30c3\u30b7\u30e5<br \/>\n\uff0810 cm\uff09<\/td>\n<td style=\"text-align: center\">\u30ec\u30dd\u30fc\u30bf\u30fc\u30d7\u30e9\u30b9\u30df\u30c9<br \/>\n\uff08\u03bcg\uff09<\/td>\n<td style=\"text-align: center\">\u30a4\u30f3\u30ad\u30e5\u30d9\u30fc\u30b7\u30e7\u30f3<br \/>\n\uff08\u6642\u9593\uff09<\/td>\n<td style=\"text-align: center\">\u30b0\u30ea\u30bb\u30ed\u30fc\u30eb<br \/>\n\uff08\u5206\uff09<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center\">1<\/td>\n<td style=\"text-align: center\">5<\/td>\n<td style=\"text-align: center\">6<\/td>\n<td style=\"text-align: center\">&#8211;<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center\">2<\/td>\n<td style=\"text-align: center\">10<\/td>\n<td style=\"text-align: center\">6<\/td>\n<td style=\"text-align: center\">&#8211;<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center\">3<\/td>\n<td style=\"text-align: center\">15<\/td>\n<td style=\"text-align: center\">6<\/td>\n<td style=\"text-align: center\">&#8211;<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center\">4<\/td>\n<td style=\"text-align: center\">20<\/td>\n<td style=\"text-align: center\">16<\/td>\n<td style=\"text-align: center\">&#8211;<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center\">5<\/td>\n<td style=\"text-align: center\">25<\/td>\n<td style=\"text-align: center\">16<\/td>\n<td style=\"text-align: center\">&#8211;<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center\">6<\/td>\n<td style=\"text-align: center\">30<\/td>\n<td style=\"text-align: center\">16<\/td>\n<td style=\"text-align: center\">&#8211;<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center\">7<\/td>\n<td style=\"text-align: center\">5<\/td>\n<td style=\"text-align: center\">6<\/td>\n<td style=\"text-align: center\">3<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center\">8<\/td>\n<td style=\"text-align: center\">10<\/td>\n<td style=\"text-align: center\">6<\/td>\n<td style=\"text-align: center\">3<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center\">9<\/td>\n<td style=\"text-align: center\">15<\/td>\n<td style=\"text-align: center\">6<\/td>\n<td style=\"text-align: center\">3<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center\">10<\/td>\n<td style=\"text-align: center\">20<\/td>\n<td style=\"text-align: center\">16<\/td>\n<td style=\"text-align: center\">3<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center\">11<\/td>\n<td style=\"text-align: center\">25<\/td>\n<td style=\"text-align: center\">16<\/td>\n<td style=\"text-align: center\">3<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center\">12<\/td>\n<td style=\"text-align: center\">30<\/td>\n<td style=\"text-align: center\">16<\/td>\n<td style=\"text-align: center\">3<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h3>\u30ab\u30c1\u30aa\u30f3\u6027\u8102\u8cea\u5a92\u4ecb\u6027\u5c0e\u5165\u306b\u5f71\u97ff\u3059\u308b\u91cd\u8981\u306a\u8981\u7d20<\/h3>\n<p><strong>\u30ab\u30c1\u30aa\u30f3\u6027\u30ea\u30dd\u30bd\u30fc\u30e0\u306b\u3088\u308bDNA\u30c8\u30e9\u30f3\u30b9\u30d5\u30a7\u30af\u30b7\u30e7\u30f3\u306e\u6210\u529f\u306b\u306f\u3001DNA\u91cf\u3001DNA\u306b\u5bfe\u3059\u308b\u30c8\u30e9\u30f3\u30b9\u30d5\u30a7\u30af\u30b7\u30e7\u30f3\u8a66\u85ac\u306e\u6bd4\u7387\u3001\u8102\u8cea-DNA\u8907\u5408\u4f53\u306e\u30a4\u30f3\u30ad\u30e5\u30d9\u30fc\u30b7\u30e7\u30f3\u6642\u9593\u3001\u304a\u3088\u3073\u8907\u5408\u4f53\u6dfb\u52a0\u6642\u306e\u7d30\u80de\u5bc6\u5ea6\u306e4\u3064\u306e\u4e3b\u8981\u306a\u30d1\u30e9\u30e1\u30fc\u30bf\u304c\u5f71\u97ff\u3057\u307e\u3059\u3002<\/strong>\u3053\u308c\u3089\u306e\u8981\u7d20\u306f\u3001\u5404\u7d30\u80de\u30bf\u30a4\u30d7\u304a\u3088\u3073\u30d9\u30af\u30bf\u30fc\u306e\u7d44\u307f\u5408\u308f\u305b\u306b\u3064\u3044\u3066\u4f53\u7cfb\u7684\u306b\u691c\u8a0e\u3059\u308b\u5fc5\u8981\u304c\u3042\u308a\u307e\u3059\u304c\u3001\u4e00\u65e6\u6700\u9069\u5316\u3059\u308b\u3068\u3001\u305d\u308c\u4ee5\u964d\u306e\u5168\u3066\u306e\u5b9f\u9a13\u306b\u304a\u3044\u3066\u4e00\u8cab\u6027\u304c\u7dad\u6301\u3055\u308c\u3001\u78ba\u5b9f\u306b\u518d\u73fe\u6027\u306e\u3042\u308b\u7d50\u679c\u304c\u5f97\u3089\u308c\u307e\u3059\u3002<\/p>\n<h4>DNA\u91cf<\/h4>\n<p><strong>DNA\u306e\u6700\u9069\u91cf\u306f\u3001\u5c0e\u5165\u3055\u308c\u305f\u30d7\u30e9\u30b9\u30df\u30c9\uff08\u4f8b\uff1a \u30d7\u30ed\u30e2\u30fc\u30bf\u30fc\u3001\u30d7\u30e9\u30b9\u30df\u30c9\u306e\u30b5\u30a4\u30ba\u3001\u8907\u88fd\u8d77\u70b9\uff09\u3001\u5c0e\u5165\u3055\u308c\u308b\u7d30\u80de\u306e\u6570\u3001\u57f9\u990a\u30c7\u30a3\u30c3\u30b7\u30e5\u306e\u30b5\u30a4\u30ba\u3001\u304a\u3088\u3073\u4f7f\u7528\u3055\u308c\u308b\u30bf\u30fc\u30b2\u30c3\u30c8\u7d30\u80de\u7cfb\u306b\u3088\u3063\u3066\u7570\u306a\u308a\u307e\u3059\u3002<\/strong>\u8a66\u9a13\u3092\u884c\u3063\u305f\u591a\u304f\u306e\u7d30\u80de\u30bf\u30a4\u30d7\u306b\u304a\u3044\u3066\u3001\u6bd4\u8f03\u7684\u5c11\u91cf\u306eDNA\u304c\u52b9\u7387\u7684\u306b\u53d6\u308a\u8fbc\u307e\u308c\u3001\u767a\u73fe\u3055\u308c\u3066\u3044\u307e\u3059\u3002\u5b9f\u969b\u3001\u4e00\u90e8\u306e\u7d30\u80de\u30bf\u30a4\u30d7\u3067\u306f\u3001\u9ad8\u30ec\u30d9\u30eb\u306eDNA\u91cf\u304c\u30ab\u30c1\u30aa\u30f3\u6027\u8102\u8cea\u8abf\u88fd\u7269\u306b\u5bfe\u3057\u3066\u963b\u5bb3\u6d3b\u6027\u3092\u793a\u3059\u53ef\u80fd\u6027\u304c\u3042\u308a\u307e\u3059\u3002\u307e\u305f\u3001\u6bd2\u6027\u30bf\u30f3\u30d1\u30af\u8cea\u3092\u30b3\u30fc\u30c9\u3059\u308b\u30d7\u30e9\u30b9\u30df\u30c9\u306e\u4f7f\u7528\u3084\u9ad8\u767a\u73fe\u7387\u3092\u3082\u305f\u3089\u3059\u904e\u5270\u306a\u30d7\u30e9\u30b9\u30df\u30c9\u3092\u4f7f\u7528\u3057\u305f\u5834\u5408\u3082\u7d30\u80de\u6bd2\u6027\u304c\u751f\u3058\u308b\u53ef\u80fd\u6027\u304c\u3042\u308a\u307e\u3059\u3002<\/p>\n<h4>DNA\u306b\u5bfe\u3059\u308b\u30c8\u30e9\u30f3\u30b9\u30d5\u30a7\u30af\u30b7\u30e7\u30f3\u8a66\u85ac\u306e\u6bd4\u7387<\/h4>\n<p><strong>\u30c8\u30e9\u30f3\u30b9\u30d5\u30a7\u30af\u30b7\u30e7\u30f3\u8907\u5408\u4f53\u306e\u5168\u4f53\u7684\u306a\u6b63\u5473\u306e\u96fb\u8377\u91cf\u306f\u3001DNA\u306b\u5bfe\u3059\u308b\u30c8\u30e9\u30f3\u30b9\u30d5\u30a7\u30af\u30b7\u30e7\u30f3\u8a66\u85ac\u306e\u6bd4\u7387\u306b\u3088\u3063\u3066\u6c7a\u5b9a\u3055\u308c\u307e\u3059\u3002<\/strong>DNA\u9aa8\u683c\u4e2d\u306e\u30ea\u30f3\u9178\u306b\u3088\u308b\u8ca0\u96fb\u8377\u306f\u3001\u826f\u597d\u306b\u8907\u5408\u4f53\u3092\u5f62\u6210\u3055\u305b\u308b\u305f\u3081\u306b\u3082\u3001\u8ca0\u306b\u8377\u96fb\u3057\u3066\u3044\u308b\u7d30\u80de\u819c\u7531\u6765\u306eDNA\u4e0a\u306e\u9759\u96fb\u53cd\u767a\u529b\u3092\u4e2d\u548c\u3059\u308b\u305f\u3081\u306b\u3082\u3001\u30c8\u30e9\u30f3\u30b9\u30d5\u30a7\u30af\u30b7\u30e7\u30f3\u8a66\u85ac\u7531\u6765\u306e\u6b63\u8377\u96fb\u306b\u3088\u3063\u3066\u76f8\u6bba\u3055\u305b\u308b\u5fc5\u8981\u304c\u3042\u308a\u307e\u3059\u3002<\/p>\n<p>DNA\u306b\u5bfe\u3059\u308b\u30c8\u30e9\u30f3\u30b9\u30d5\u30a7\u30af\u30b7\u30e7\u30f3\u8a66\u85ac\u306e\u6700\u9069\u306a\u6bd4\u7387\u306f\u3001\u7d30\u80de\u30bf\u30a4\u30d7\u306b\u5927\u304d\u304f\u4f9d\u5b58\u3057\u307e\u3059\u3002\u958b\u59cb\u6642\u70b9\u306b\u304a\u3044\u3066\u3001\u30d7\u30e9\u30b9\u30df\u30c9DNA\u6fc3\u5ea6\u306f\u4e00\u5b9a\u306b\u4fdd\u3061\u3001\u30c8\u30e9\u30f3\u30b9\u30d5\u30a7\u30af\u30b7\u30e7\u30f3\u8a66\u85ac\u306e\u91cf\u3092\u5909\u5316\u3055\u305b\u307e\u3059\uff08\u4f8b\uff1a 1\uff1a1\u30013\uff1a1\u304a\u3088\u30735\uff1a1 \u8cea\u91cf\uff0f\u4f53\u7a4d\u6bd4\uff09\u3002\u3053\u306e\u6bd4\u7387\u3092\u7dad\u6301\u3057\u3066\u3001\u6dfb\u52a0\u3059\u308b\u30d7\u30e9\u30b9\u30df\u30c9\u91cf\u3092\u5897\u52a0\u3055\u305b\u308b\u3053\u3068\u306b\u3088\u3063\u3066\u3001\u3055\u3089\u306a\u308b\u30e1\u30ea\u30c3\u30c8\u304c\u5f97\u3089\u308c\u308b\u53ef\u80fd\u6027\u304c\u3042\u308a\u307e\u3059\u3002<\/p>\n<h4>\u30a4\u30f3\u30ad\u30e5\u30d9\u30fc\u30b7\u30e7\u30f3\u6642\u9593<\/h4>\n<p><strong>\u7d30\u80de\u3068\u30c8\u30e9\u30f3\u30b9\u30d5\u30a7\u30af\u30b7\u30e7\u30f3\u8907\u5408\u4f53\u306e\u6700\u9069\u306a\u30a4\u30f3\u30ad\u30e5\u30d9\u30fc\u30b7\u30e7\u30f3\u6642\u9593\u306f\u7d30\u80de\u7cfb\u304a\u3088\u3073\u4f7f\u7528\u3057\u305f\u30c8\u30e9\u30f3\u30b9\u30d5\u30a7\u30af\u30b7\u30e7\u30f3\u8a66\u85ac\u306b\u4f9d\u5b58\u3057\u307e\u3059\u3002<\/strong>\u901a\u5e38\u3001\u30c8\u30e9\u30f3\u30b9\u30d5\u30a7\u30af\u30b7\u30e7\u30f3\u52b9\u7387\u306f\u8102\u8cea\u8a66\u85ac-DNA\u8907\u5408\u4f53\u3078\u306e\u66dd\u9732\u6642\u9593\u306b\u4f34\u3063\u3066\u5897\u52a0\u3057\u307e\u3059\u3002\u3068\u306f\u3044\u3048\u3001\u7279\u5b9a\u306e\u8102\u8cea\u8a66\u85ac\u3078\u306e\u9577\u6642\u9593\u66dd\u9732\u306f\u6bd2\u6027\u72b6\u614b\u3092\u9ad8\u3081\u308b\u305f\u3081\u3001\u30a4\u30f3\u30ad\u30e5\u30d9\u30fc\u30b7\u30e7\u30f3\u6642\u9593\u304c\u7d42\u4e86\u3057\u305f\u3089\u3001\u7d30\u80de\u6bd2\u6027\u306e\u5f71\u97ff\u3092\u6700\u5c0f\u9650\u306b\u6291\u3048\u308b\u305f\u3081\u306b\u3001\u9060\u5fc3\u5206\u96e2\u306b\u3088\u308b\u9664\u53bb\u3084\u65b0\u3057\u3044\u57f9\u5730\u306b\u3088\u308b\u5e0c\u91c8\u304c\u5fc5\u8981\u3068\u3055\u308c\u307e\u3059\u3002<a href=\"http:\/\/www.thermofisher.com\/jp\/ja\/home\/life-science\/protein-expression-and-analysis\/transfection-selection\/lipofectamine-3000.html?CID=bid_clb_tfx_r04_jp_cp0000_pjt0000_bid00000_0so_blg_op_awa_oc_s00_cc16_Social_LAB\" target=\"_blank\" rel=\"noopener noreferrer\">Lipofectamine 3000<\/a>\u8a66\u85ac\u306e\u3088\u3046\u306a\u65b0\u3057\u3044\u7a4f\u548c\u306a\u8a66\u85ac\u3067\u306f\u30c8\u30e9\u30f3\u30b9\u30d5\u30a7\u30af\u30b7\u30e7\u30f3\u5f8c\u306e\u8907\u5408\u4f53\u306e\u9664\u53bb\u3084\u5e0c\u91c8\u306f\u5fc5\u8981\u3042\u308a\u307e\u305b\u3093\u3002<\/p>\n<p>\u57f9\u5730\u306e\u6dfb\u52a0\u3084\u7f6e\u63db\u304c\u5fc5\u8981\u3068\u3055\u308c\u308b\u30ab\u30c1\u30aa\u30f3\u6027\u8102\u8cea\u8a66\u85ac\u3092\u4f7f\u7528\u3059\u308b\u5834\u5408\u306f\u3001\u8907\u5408\u4f53\u6dfb\u52a0\u5f8c\u306e\u30a4\u30f3\u30ad\u30e5\u30d9\u30fc\u30b7\u30e7\u30f3\u6642\u9593\u3092\u5909\u5316\u3055\u305b\u3066\uff08\u4f8b\uff1a 30\u5206\uff5e4\u6642\u9593\u3001\u307e\u305f\u306f\u4e00\u6669\uff09\u3001\u3053\u306e\u9593\u306e\u7d30\u80de\u5f62\u614b\u3092\u30e2\u30cb\u30bf\u30fc\u3057\u307e\u3059\u3002\u7279\u306b\u7d30\u80de\u3092\u7121\u8840\u6e05\u57f9\u5730\u306b\u7dad\u6301\u3057\u305f\u5834\u5408\u306f\u3001\u4e00\u90e8\u306e\u7d30\u80de\u7cfb\u3067\u306f\u3053\u308c\u3089\u306e\u6761\u4ef6\u4e0b\u3067\u751f\u5b58\u80fd\u304c\u5931\u308f\u308c\u307e\u3059\u3002<\/p>\n<h4>\u7d30\u80de\u5bc6\u5ea6<\/h4>\n<p><strong>\u7d30\u80de\u5bc6\u5ea6\u306f\u5168\u30c8\u30e9\u30f3\u30b9\u30d5\u30a7\u30af\u30b7\u30e7\u30f3\u52b9\u7387\u306b\u3082\u5f71\u97ff\u3057\u307e\u3059\u3002<\/strong>\u8ee2\u5199\u304a\u3088\u3073\u6700\u7d42\u7684\u306a\u30bf\u30f3\u30d1\u30af\u8cea\u751f\u7523\u3092\u9054\u6210\u3059\u308b\u305f\u3081\u306b\u306f\u3001DNA\u306e\u6838\u5185\u5c40\u5728\u304c\u5fc5\u8981\u3068\u3055\u308c\u3001\u305d\u308c\u306f\u6709\u7cf8\u5206\u88c2\u4e2d\u306e\u819c\u306e\u5206\u89e3\u3068\u518d\u7de8\u6210\u306b\u5927\u304d\u304f\u4f9d\u5b58\u3057\u3001\u7d30\u80de\u304c\u6d3b\u767a\u306b\u5206\u88c2\u3059\u308b\u3053\u3068\u304c\u5fc5\u8981\u3068\u3055\u308c\u307e\u3059\u3002<\/p>\n<p>\u63a5\u7740\u7d30\u80de\u3067\u306f\u3001\u591a\u304f\u306e\u5834\u5408\u300180%\u306e\u30b3\u30f3\u30d5\u30eb\u30a8\u30f3\u30b7\u30fc\u3067\u6700\u9ad8\u306e\u52b9\u7387\u306b\u5230\u9054\u3057\u307e\u3059\u304c\u3001\u30d7\u30ed\u30c8\u30b3\u30fc\u30eb\u3067\u306f40\uff5e90%\u306e\u7bc4\u56f2\u306e\u30b3\u30f3\u30d5\u30eb\u30a8\u30f3\u30b7\u30fc\u304c\u63a8\u5968\u3055\u308c\u3066\u3044\u307e\u3059\u3002\u6d6e\u904a\u7d30\u80de\u3067\u306f\u3001\u78ba\u5b9f\u306b\u30c8\u30e9\u30f3\u30b9\u30d5\u30a7\u30af\u30b7\u30e7\u30f3\u51e6\u7406\u306b\u6700\u9069\u306a\u751f\u7406\u7684\u72b6\u614b\u306b\u3057\u3066\u304a\u304f\u305f\u3081\u306b\u3001\u30c8\u30e9\u30f3\u30b9\u30d5\u30a7\u30af\u30b7\u30e7\u30f3\u306e1\u65e5\u524d\u306b\u7d30\u80de\u3092\u5206\u88c2\u3055\u305b\u308b\u3053\u3068\u3092\u63a8\u5968\u3057\u307e\u3059\u3002\u6700\u9069\u306a\u7d30\u80de\u5bc6\u5ea6\u306f\u3001\u7d30\u80de\u30bf\u30a4\u30d7\u304a\u3088\u3073\u8a66\u85ac\u7279\u7570\u7684\u306a\u6bd2\u6027\u306b\u5927\u304d\u304f\u4f9d\u5b58\u3059\u308b\u305f\u3081\u3001\u7d4c\u9a13\u7684\u306b\u6c7a\u5b9a\u3059\u308b\u5fc5\u8981\u304c\u3042\u308a\u307e\u3059\u3002<\/p>\n<h3>\u30a8\u30ec\u30af\u30c8\u30ed\u30dd\u30ec\u30fc\u30b7\u30e7\u30f3\u306b\u5f71\u97ff\u3059\u308b\u91cd\u8981\u306a\u8981\u7d20<\/h3>\n<p><strong>\u30a8\u30ec\u30af\u30c8\u30ed\u30dd\u30ec\u30fc\u30b7\u30e7\u30f3\u306f\u3001\u30d1\u30eb\u30b9\u96fb\u5727\u3001\u30d1\u30eb\u30b9\u5e45\u3001\u304a\u3088\u3073\u30d1\u30eb\u30b9\u6570\u306e\u4e3b\u306b3\u7a2e\u985e\u306e\u96fb\u6c17\u7684\u30d1\u30e9\u30e1\u30fc\u30bf\u306e\u7d44\u307f\u5408\u308f\u305b\u306b\u4f9d\u5b58\u3057\u307e\u3059\u3002<\/strong>\u30a8\u30ec\u30af\u30c8\u30ed\u30dd\u30ec\u30fc\u30b7\u30e7\u30f3\u306f\u5316\u5b66\u7684\u624b\u6cd5\u30d9\u30fc\u30b9\u306e\u30d7\u30ed\u30c8\u30b3\u30fc\u30eb\u3067\u306f\u306a\u3044\u305f\u3081\u3001DNA\u6fc3\u5ea6\u306e\u5f71\u97ff\u3092\u307b\u3068\u3093\u3069\u53d7\u3051\u307e\u305b\u3093\u3002\u3057\u304b\u3057\u3001\u30ea\u30f3\u9178\u30ab\u30eb\u30b7\u30a6\u30e0\u5a92\u4ecb\u6027\u30c8\u30e9\u30f3\u30b9\u30d5\u30a7\u30af\u30b7\u30e7\u30f3\u306e\u307b\u307c5\u500d\u4ee5\u4e0a\u306e\u7d30\u80de\u304a\u3088\u3073DNA\u304c\u5fc5\u8981\u3068\u3055\u308c\u307e\u3059\u3002\u901a\u5e38\u300110<sup>7<\/sup>\u500b\u306e\u7d30\u80de\u5f53\u305f\u308a1\uff5e5 \u03bcg\u306eDNA\u304c\u3042\u308c\u3070\u5341\u5206\u3067\u3001DNA\u306e\u5b58\u5728\u91cf\u3068\u53d6\u308a\u8fbc\u307e\u308c\u308b\u91cf\u3068\u306e\u9593\u306b\u9ad8\u3044\u76f8\u95a2\u304c\u3042\u308a\u307e\u3059\u3002<\/p>\n<p>\u30a8\u30ec\u30af\u30c8\u30ed\u30dd\u30ec\u30fc\u30b7\u30e7\u30f3\u30d1\u30e9\u30e1\u30fc\u30bf\u3092\u6700\u9069\u5316\u3059\u308b\u305f\u3081\u306b\u306f\u300140\uff5e80%\u306e\u7d30\u80de\u751f\u5b58\u7387\u3092\u7dad\u6301\u3059\u308b\u30d1\u30eb\u30b9\u3092\u898b\u3064\u3051\u307e\u3059\u3002\u30d1\u30eb\u30b9\u5e45\u306f\u3001\u96fb\u6e90\u306e\u96fb\u6c17\u5bb9\u91cf\u306b\u3088\u3063\u3066\u6c7a\u5b9a\u3055\u308c\u3001\u96fb\u6e90\u306b\u3088\u3063\u3066\u767a\u751f\u3059\u308b\u96fb\u5727\u306b\u4f9d\u5b58\u3057\u3066\u5909\u5316\u3057\u307e\u3059\u3002\u904e\u5ea6\u306e\u7d30\u80de\u6b7b\u304c\u751f\u3058\u308b\u5834\u5408\u306f\u3001\u96fb\u6c17\u5bb9\u91cf\u3092\u4f4e\u4e0b\u3055\u305b\u308b\u3053\u3068\u306b\u3088\u308a\u30d1\u30eb\u30b9\u306e\u9577\u3055\u3092\u77ed\u304f\u3067\u304d\u307e\u3059\u3002\u7d30\u80de\u3092\u6c37\u4e0a\u306b\u7dad\u6301\u3059\u308b\u3053\u3068\u3067\u3001\u591a\u304f\u306e\u5834\u5408\uff08\u7279\u306b\u71b1\u3092\u767a\u751f\u3059\u308b\u9ad8\u51fa\u529b\u96fb\u6e90\u3067\u306f\uff09\u3001\u7d30\u80de\u751f\u5b58\u7387\u304c\u6539\u5584\u3057\u3001\u3088\u308a\u52b9\u7387\u7684\u306a\u30c8\u30e9\u30f3\u30b9\u30d5\u30a7\u30af\u30b7\u30e7\u30f3\u7387\u304c\u5f97\u3089\u308c\u307e\u3059\uff08Potter et al., 1984\uff09\u3002\u3057\u304b\u3057\u3001\u4e00\u90e8\u306e\u7d30\u80de\u7cfb\u3067\u306f\u3001\u4f4e\u96fb\u5727\uff0f\u9ad8\u5bb9\u91cf\u306e\u6761\u4ef6\u4e0b\u3067\u3001\u5ba4\u6e29\u306b\u304a\u3044\u3066\u9ad8\u52b9\u7387\u306a\u30a8\u30ec\u30af\u30c8\u30ed\u30dd\u30ec\u30fc\u30b7\u30e7\u30f3\u304c\u884c\u3048\u307e\u3059\uff08Chu et al., 1991\uff09\u3002<\/p>\n<p><a href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/life-science\/cell-culture\/transfection\/neon-transfection-system.html?CID=bid_clb_tfx_r04_jp_cp0000_pjt0000_bid00000_0so_blg_op_awa_oc_s00_cc16_Social_LAB\" target=\"_blank\" rel=\"noopener noreferrer\">Neon Transfection System<\/a>\u306f\u300118-\u304a\u3088\u307324-\u30a6\u30a7\u30eb\u7528\u306b\u6700\u9069\u5316\u3055\u308c\u305f\u30d7\u30ed\u30c8\u30b3\u30fc\u30eb\u304c\u4e88\u3081\u30d7\u30ed\u30b0\u30e9\u30e0\u3055\u308c\u3066\u304a\u308a\u3001\u6570\u65e5\u4ee5\u5185\u306b\u591a\u6570\u306e\u63a5\u7740\u304a\u3088\u3073\u6d6e\u904a\u7d30\u80de\u7cfb\u7528\u306e\u96fb\u6c17\u7684\u30d1\u30e9\u30e1\u30fc\u30bf\u3092\u8fc5\u901f\u306b\u6700\u9069\u5316\u3067\u304d\u307e\u3059\u3002\u307e\u305f\u3001Neon Transfection System\u7528\u306e\u7d30\u80de\u7cfb\u7279\u7570\u7684\u306b\u6700\u9069\u5316\u3055\u308c\u305f\u30d7\u30ed\u30c8\u30b3\u30fc\u30eb\u3082<a href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/life-science\/cell-culture\/transfection\/neon-transfection-system.html?CID=bid_clb_tfx_r04_jp_cp0000_pjt0000_bid00000_0so_blg_op_awa_oc_s00_cc16_Social_LAB\" target=\"_blank\" rel=\"noopener noreferrer\">\u30a6\u30a7\u30d6\u30b5\u30a4\u30c8<\/a>\u304b\u3089\u7c21\u5358\u306b\u30c0\u30a6\u30f3\u30ed\u30fc\u30c9\u3059\u308b\u3053\u3068\u304c\u3067\u304d\u3001\u591a\u304f\u306e\u901a\u5e38\u7528\u3044\u3089\u308c\u3066\u3044\u308b\u7d30\u80de\u30bf\u30a4\u30d7\u3078\u306e\u30c8\u30e9\u30f3\u30b9\u30d5\u30a7\u30af\u30b7\u30e7\u30f3\u52b9\u7387\u3092\u6700\u5927\u5316\u3067\u304d\u307e\u3059\u3002<\/p>\n<h2>\u3010\u7121\u6599\u30c0\u30a6\u30f3\u30ed\u30fc\u30c9\u3011Gibco\u7d30\u80de\u57f9\u990a\u57fa\u790e\u30cf\u30f3\u30c9\u30d6\u30c3\u30af<\/h2>\n<p>\u7d30\u80de\u57f9\u990a\u306b\u95a2\u3059\u308b\u57fa\u790e\u60c5\u5831\u3092\u89e3\u8aac\u3057\u305f\u30cf\u30f3\u30c9\u30d6\u30c3\u30af\u3092\u3054\u7528\u610f\u3057\u3066\u3044\u307e\u3059\uff08\u65e5\u672c\u8a9e\u7248\u3001\u7d04100\u30da\u30fc\u30b8\uff09\u3002PDF\u30d5\u30a1\u30a4\u30eb\u306e\u30c0\u30a6\u30f3\u30ed\u30fc\u30c9\u3092\u3054\u5e0c\u671b\u306e\u65b9\u306f\u3001\u4e0b\u8a18\u30dc\u30bf\u30f3\u3088\u308a\u304a\u7533\u3057\u8fbc\u307f\u304f\u3060\u3055\u3044\u3002<br \/>\n<a class=\"btn btn-red\" href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/global\/forms\/gibco-cell-culture-basics-handbook-form.html?CID=bid_clb_tfx_r04_jp_cp0000_pjt0000_bid00000_0so_blg_op_awa_oc_s00_cc16_Social_LAB\" target=\"_blank\" rel=\"noopener\">\u30c0\u30a6\u30f3\u30ed\u30fc\u30c9<\/a><\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>\u7814\u7a76\u7528\u306b\u306e\u307f\u4f7f\u7528\u3067\u304d\u307e\u3059\u3002\u8a3a\u65ad\u76ee\u7684\u304a\u3088\u3073\u305d\u306e\u624b\u7d9a\u304d\u4e0a\u3067\u306e\u4f7f\u7528\u306f\u3067\u304d\u307e\u305b\u3093\u3002<\/p>\n","protected":false},"excerpt":{"rendered":"<p>\u53e4\u5178\u7684\u306a\u30c8\u30e9\u30f3\u30b9\u30d5\u30a7\u30af\u30b7\u30e7\u30f3\u6280\u8853\u306f\u3001\u5f53\u521d\u3001\u30d7\u30e9\u30b9\u30df\u30c9DNA\u3092\u7d30\u80de\u306b\u5c0e\u5165\u3059\u308b\u305f\u3081\u306b\u958b\u767a\u3055\u308c\u307e\u3057\u305f\u304c\u3001\u30d7\u30e9\u30b9\u30df\u30c9DNA\u306f\u30c8\u30e9\u30f3\u30b9\u30d5\u30a7\u30af\u30b7\u30e7\u30f3\u306e\u305f\u3081\u306e\u6700\u3082\u4e00\u822c\u7684\u306a\u30d9\u30af\u30bf\u30fc\u3068\u3057\u3066\u73fe\u5728\u3082\u5b58\u5728\u3057\u3066\u3044\u307e\u3059\u3002\u4eca\u56de\u306f\u3001\u30d7\u30e9\u30b9\u30df\u30c9DNA\u3092\u7528\u3044\u305f\u30c8\u30e9\u30f3\u30b9\u30d5\u30a7\u30af\u30b7\u30e7\u30f3\u306b\u3064\u3044\u3066\u306e\u30ac\u30a4\u30c9\u30e9\u30a4\u30f3\u3068\u30d1\u30e9\u30e1\u30fc\u30bf\u306e\u6700\u9069\u5316\u65b9\u6cd5\u306b\u3064\u3044\u3066\u3054\u7d39\u4ecb\u3057\u307e\u3059\u3002<\/p>\n","protected":false},"author":988,"featured_media":2933,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_monsterinsights_skip_tracking":false,"_genesis_hide_title":false,"_genesis_hide_breadcrumbs":false,"_genesis_hide_singular_image":false,"_genesis_hide_footer_widgets":false,"_genesis_custom_body_class":"","_genesis_custom_post_class":"","_genesis_layout":"","_jetpack_newsletter_access":"","_jetpack_dont_email_post_to_subs":false,"_jetpack_newsletter_tier_id":0,"_jetpack_memberships_contains_paywalled_content":false,"_jetpack_feature_clip_id":0,"_jetpack_memberships_contains_paid_content":false,"footnotes":"","jetpack_post_was_ever_published":false},"categories":[159],"tags":[67],"division":[],"class_list":{"0":"post-569","1":"post","2":"type-post","3":"status-publish","4":"format-standard","5":"has-post-thumbnail","7":"category-cell","8":"tag-transfection","9":"entry"},"_selected_authors":"","_selected_reviewers":"","acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v27.8 (Yoast SEO v27.8) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>\u30d7\u30e9\u30b9\u30df\u30c9DNA\u30c8\u30e9\u30f3\u30b9\u30d5\u30a7\u30af\u30b7\u30e7\u30f3\u306e\u305f\u3081\u306e\u30ac\u30a4\u30c9\u30e9\u30a4\u30f3\u3068\u6700\u9069\u5316\u65b9\u6cd5 - Learning at the Bench<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/guidelines-and-optimizing-for-plasmid-dna-transfection\/\" \/>\n<meta property=\"og:locale\" content=\"ja_JP\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"\u30d7\u30e9\u30b9\u30df\u30c9DNA\u30c8\u30e9\u30f3\u30b9\u30d5\u30a7\u30af\u30b7\u30e7\u30f3\u306e\u305f\u3081\u306e\u30ac\u30a4\u30c9\u30e9\u30a4\u30f3\u3068\u6700\u9069\u5316\u65b9\u6cd5\" \/>\n<meta property=\"og:description\" content=\"\u53e4\u5178\u7684\u306a\u30c8\u30e9\u30f3\u30b9\u30d5\u30a7\u30af\u30b7\u30e7\u30f3\u6280\u8853\u306f\u3001\u5f53\u521d\u3001\u30d7\u30e9\u30b9\u30df\u30c9DNA\u3092\u7d30\u80de\u306b\u5c0e\u5165\u3059\u308b\u305f\u3081\u306b\u958b\u767a\u3055\u308c\u307e\u3057\u305f\u304c\u3001\u30d7\u30e9\u30b9\u30df\u30c9DNA\u306f\u30c8\u30e9\u30f3\u30b9\u30d5\u30a7\u30af\u30b7\u30e7\u30f3\u306e\u305f\u3081\u306e\u6700\u3082\u4e00\u822c\u7684\u306a\u30d9\u30af\u30bf\u30fc\u3068\u3057\u3066\u73fe\u5728\u3082\u5b58\u5728\u3057\u3066\u3044\u307e\u3059\u3002\u4eca\u56de\u306f\u3001\u30d7\u30e9\u30b9\u30df\u30c9DNA\u3092\u7528\u3044\u305f\u30c8\u30e9\u30f3\u30b9\u30d5\u30a7\u30af\u30b7\u30e7\u30f3\u306b\u3064\u3044\u3066\u306e\u30ac\u30a4\u30c9\u30e9\u30a4\u30f3\u3068\u30d1\u30e9\u30e1\u30fc\u30bf\u306e\u6700\u9069\u5316\u65b9\u6cd5\u306b\u3064\u3044\u3066\u3054\u7d39\u4ecb\u3057\u307e\u3059\u3002\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/guidelines-and-optimizing-for-plasmid-dna-transfection\/\" \/>\n<meta property=\"og:site_name\" content=\"Learning at the Bench\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/ThermoFisherJapan\" \/>\n<meta property=\"article:published_time\" content=\"2017-02-02T00:00:00+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2025-02-26T08:16:28+00:00\" \/>\n<meta property=\"og:image\" content=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/guidelines-and-optimizing-for-plasmid-dna-transfection-title.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"1200\" \/>\n\t<meta property=\"og:image:height\" content=\"631\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"LATB Staff\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:creator\" content=\"@ThermoFisherJP\" \/>\n<meta name=\"twitter:site\" content=\"@ThermoFisherJP\" \/>\n<meta name=\"twitter:label1\" content=\"\u57f7\u7b46\u8005\" \/>\n\t<meta name=\"twitter:data1\" content=\"LATB Staff\" \/>\n\t<meta name=\"twitter:label2\" content=\"\u63a8\u5b9a\u8aad\u307f\u53d6\u308a\u6642\u9593\" \/>\n\t<meta name=\"twitter:data2\" content=\"19\u5206\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/guidelines-and-optimizing-for-plasmid-dna-transfection\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/guidelines-and-optimizing-for-plasmid-dna-transfection\\\/\"},\"author\":{\"name\":\"LATB Staff\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#\\\/schema\\\/person\\\/00a095a01d54afcdf9457465feb04f7d\"},\"headline\":\"\u30d7\u30e9\u30b9\u30df\u30c9DNA\u30c8\u30e9\u30f3\u30b9\u30d5\u30a7\u30af\u30b7\u30e7\u30f3\u306e\u305f\u3081\u306e\u30ac\u30a4\u30c9\u30e9\u30a4\u30f3\u3068\u6700\u9069\u5316\u65b9\u6cd5\",\"datePublished\":\"2017-02-02T00:00:00+00:00\",\"dateModified\":\"2025-02-26T08:16:28+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/guidelines-and-optimizing-for-plasmid-dna-transfection\\\/\"},\"wordCount\":141,\"commentCount\":0,\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/guidelines-and-optimizing-for-plasmid-dna-transfection\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2019\\\/07\\\/guidelines-and-optimizing-for-plasmid-dna-transfection-title.jpg\",\"keywords\":[\"\u30c8\u30e9\u30f3\u30b9\u30d5\u30a7\u30af\u30b7\u30e7\u30f3\"],\"articleSection\":[\"\u7d30\u80de\u57f9\u990a\u30fb\u30a4\u30e1\u30fc\u30b8\u30f3\u30b0\"],\"inLanguage\":\"ja\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/guidelines-and-optimizing-for-plasmid-dna-transfection\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/guidelines-and-optimizing-for-plasmid-dna-transfection\\\/\",\"url\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/guidelines-and-optimizing-for-plasmid-dna-transfection\\\/\",\"name\":\"\u30d7\u30e9\u30b9\u30df\u30c9DNA\u30c8\u30e9\u30f3\u30b9\u30d5\u30a7\u30af\u30b7\u30e7\u30f3\u306e\u305f\u3081\u306e\u30ac\u30a4\u30c9\u30e9\u30a4\u30f3\u3068\u6700\u9069\u5316\u65b9\u6cd5 - Learning at the Bench\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/guidelines-and-optimizing-for-plasmid-dna-transfection\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/guidelines-and-optimizing-for-plasmid-dna-transfection\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2019\\\/07\\\/guidelines-and-optimizing-for-plasmid-dna-transfection-title.jpg\",\"datePublished\":\"2017-02-02T00:00:00+00:00\",\"dateModified\":\"2025-02-26T08:16:28+00:00\",\"author\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#\\\/schema\\\/person\\\/00a095a01d54afcdf9457465feb04f7d\"},\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/guidelines-and-optimizing-for-plasmid-dna-transfection\\\/#breadcrumb\"},\"inLanguage\":\"ja\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/guidelines-and-optimizing-for-plasmid-dna-transfection\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"ja\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/guidelines-and-optimizing-for-plasmid-dna-transfection\\\/#primaryimage\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2019\\\/07\\\/guidelines-and-optimizing-for-plasmid-dna-transfection-title.jpg\",\"contentUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2019\\\/07\\\/guidelines-and-optimizing-for-plasmid-dna-transfection-title.jpg\",\"width\":1200,\"height\":631,\"caption\":\"guidelines-and-optimizing-for-plasmid-dna-transfection-title\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/guidelines-and-optimizing-for-plasmid-dna-transfection\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"\u30d7\u30e9\u30b9\u30df\u30c9DNA\u30c8\u30e9\u30f3\u30b9\u30d5\u30a7\u30af\u30b7\u30e7\u30f3\u306e\u305f\u3081\u306e\u30ac\u30a4\u30c9\u30e9\u30a4\u30f3\u3068\u6700\u9069\u5316\u65b9\u6cd5\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#website\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/\",\"name\":\"Learning at the Bench\",\"description\":\"\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"ja\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#\\\/schema\\\/person\\\/00a095a01d54afcdf9457465feb04f7d\",\"name\":\"LATB Staff\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"ja\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/8803277856c8b753feb4217dff0f9953327452df1a615c3c88b2f9864efb2ddd?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/8803277856c8b753feb4217dff0f9953327452df1a615c3c88b2f9864efb2ddd?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/8803277856c8b753feb4217dff0f9953327452df1a615c3c88b2f9864efb2ddd?s=96&d=mm&r=g\",\"caption\":\"LATB Staff\"},\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/author\\\/latbstaff\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"\u30d7\u30e9\u30b9\u30df\u30c9DNA\u30c8\u30e9\u30f3\u30b9\u30d5\u30a7\u30af\u30b7\u30e7\u30f3\u306e\u305f\u3081\u306e\u30ac\u30a4\u30c9\u30e9\u30a4\u30f3\u3068\u6700\u9069\u5316\u65b9\u6cd5 - Learning at the Bench","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/guidelines-and-optimizing-for-plasmid-dna-transfection\/","og_locale":"ja_JP","og_type":"article","og_title":"\u30d7\u30e9\u30b9\u30df\u30c9DNA\u30c8\u30e9\u30f3\u30b9\u30d5\u30a7\u30af\u30b7\u30e7\u30f3\u306e\u305f\u3081\u306e\u30ac\u30a4\u30c9\u30e9\u30a4\u30f3\u3068\u6700\u9069\u5316\u65b9\u6cd5","og_description":"\u53e4\u5178\u7684\u306a\u30c8\u30e9\u30f3\u30b9\u30d5\u30a7\u30af\u30b7\u30e7\u30f3\u6280\u8853\u306f\u3001\u5f53\u521d\u3001\u30d7\u30e9\u30b9\u30df\u30c9DNA\u3092\u7d30\u80de\u306b\u5c0e\u5165\u3059\u308b\u305f\u3081\u306b\u958b\u767a\u3055\u308c\u307e\u3057\u305f\u304c\u3001\u30d7\u30e9\u30b9\u30df\u30c9DNA\u306f\u30c8\u30e9\u30f3\u30b9\u30d5\u30a7\u30af\u30b7\u30e7\u30f3\u306e\u305f\u3081\u306e\u6700\u3082\u4e00\u822c\u7684\u306a\u30d9\u30af\u30bf\u30fc\u3068\u3057\u3066\u73fe\u5728\u3082\u5b58\u5728\u3057\u3066\u3044\u307e\u3059\u3002\u4eca\u56de\u306f\u3001\u30d7\u30e9\u30b9\u30df\u30c9DNA\u3092\u7528\u3044\u305f\u30c8\u30e9\u30f3\u30b9\u30d5\u30a7\u30af\u30b7\u30e7\u30f3\u306b\u3064\u3044\u3066\u306e\u30ac\u30a4\u30c9\u30e9\u30a4\u30f3\u3068\u30d1\u30e9\u30e1\u30fc\u30bf\u306e\u6700\u9069\u5316\u65b9\u6cd5\u306b\u3064\u3044\u3066\u3054\u7d39\u4ecb\u3057\u307e\u3059\u3002","og_url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/guidelines-and-optimizing-for-plasmid-dna-transfection\/","og_site_name":"Learning at the Bench","article_publisher":"https:\/\/www.facebook.com\/ThermoFisherJapan","article_published_time":"2017-02-02T00:00:00+00:00","article_modified_time":"2025-02-26T08:16:28+00:00","og_image":[{"width":1200,"height":631,"url":"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/guidelines-and-optimizing-for-plasmid-dna-transfection-title.jpg","type":"image\/jpeg"}],"author":"LATB Staff","twitter_card":"summary_large_image","twitter_creator":"@ThermoFisherJP","twitter_site":"@ThermoFisherJP","twitter_misc":{"\u57f7\u7b46\u8005":"LATB Staff","\u63a8\u5b9a\u8aad\u307f\u53d6\u308a\u6642\u9593":"19\u5206"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/guidelines-and-optimizing-for-plasmid-dna-transfection\/#article","isPartOf":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/guidelines-and-optimizing-for-plasmid-dna-transfection\/"},"author":{"name":"LATB Staff","@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#\/schema\/person\/00a095a01d54afcdf9457465feb04f7d"},"headline":"\u30d7\u30e9\u30b9\u30df\u30c9DNA\u30c8\u30e9\u30f3\u30b9\u30d5\u30a7\u30af\u30b7\u30e7\u30f3\u306e\u305f\u3081\u306e\u30ac\u30a4\u30c9\u30e9\u30a4\u30f3\u3068\u6700\u9069\u5316\u65b9\u6cd5","datePublished":"2017-02-02T00:00:00+00:00","dateModified":"2025-02-26T08:16:28+00:00","mainEntityOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/guidelines-and-optimizing-for-plasmid-dna-transfection\/"},"wordCount":141,"commentCount":0,"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/guidelines-and-optimizing-for-plasmid-dna-transfection\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/guidelines-and-optimizing-for-plasmid-dna-transfection-title.jpg","keywords":["\u30c8\u30e9\u30f3\u30b9\u30d5\u30a7\u30af\u30b7\u30e7\u30f3"],"articleSection":["\u7d30\u80de\u57f9\u990a\u30fb\u30a4\u30e1\u30fc\u30b8\u30f3\u30b0"],"inLanguage":"ja","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/guidelines-and-optimizing-for-plasmid-dna-transfection\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/guidelines-and-optimizing-for-plasmid-dna-transfection\/","url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/guidelines-and-optimizing-for-plasmid-dna-transfection\/","name":"\u30d7\u30e9\u30b9\u30df\u30c9DNA\u30c8\u30e9\u30f3\u30b9\u30d5\u30a7\u30af\u30b7\u30e7\u30f3\u306e\u305f\u3081\u306e\u30ac\u30a4\u30c9\u30e9\u30a4\u30f3\u3068\u6700\u9069\u5316\u65b9\u6cd5 - Learning at the Bench","isPartOf":{"@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/guidelines-and-optimizing-for-plasmid-dna-transfection\/#primaryimage"},"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/guidelines-and-optimizing-for-plasmid-dna-transfection\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/guidelines-and-optimizing-for-plasmid-dna-transfection-title.jpg","datePublished":"2017-02-02T00:00:00+00:00","dateModified":"2025-02-26T08:16:28+00:00","author":{"@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#\/schema\/person\/00a095a01d54afcdf9457465feb04f7d"},"breadcrumb":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/guidelines-and-optimizing-for-plasmid-dna-transfection\/#breadcrumb"},"inLanguage":"ja","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/guidelines-and-optimizing-for-plasmid-dna-transfection\/"]}]},{"@type":"ImageObject","inLanguage":"ja","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/guidelines-and-optimizing-for-plasmid-dna-transfection\/#primaryimage","url":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/guidelines-and-optimizing-for-plasmid-dna-transfection-title.jpg","contentUrl":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/guidelines-and-optimizing-for-plasmid-dna-transfection-title.jpg","width":1200,"height":631,"caption":"guidelines-and-optimizing-for-plasmid-dna-transfection-title"},{"@type":"BreadcrumbList","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/guidelines-and-optimizing-for-plasmid-dna-transfection\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/"},{"@type":"ListItem","position":2,"name":"\u30d7\u30e9\u30b9\u30df\u30c9DNA\u30c8\u30e9\u30f3\u30b9\u30d5\u30a7\u30af\u30b7\u30e7\u30f3\u306e\u305f\u3081\u306e\u30ac\u30a4\u30c9\u30e9\u30a4\u30f3\u3068\u6700\u9069\u5316\u65b9\u6cd5"}]},{"@type":"WebSite","@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#website","url":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/","name":"Learning at the Bench","description":"","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"ja"},{"@type":"Person","@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#\/schema\/person\/00a095a01d54afcdf9457465feb04f7d","name":"LATB Staff","image":{"@type":"ImageObject","inLanguage":"ja","@id":"https:\/\/secure.gravatar.com\/avatar\/8803277856c8b753feb4217dff0f9953327452df1a615c3c88b2f9864efb2ddd?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/8803277856c8b753feb4217dff0f9953327452df1a615c3c88b2f9864efb2ddd?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/8803277856c8b753feb4217dff0f9953327452df1a615c3c88b2f9864efb2ddd?s=96&d=mm&r=g","caption":"LATB Staff"},"url":"https:\/\/admin.acceleratingscience.com\/author\/latbstaff\/"}]}},"taxonomy_info":{"category":[{"value":159,"label":"\u7d30\u80de\u57f9\u990a\u30fb\u30a4\u30e1\u30fc\u30b8\u30f3\u30b0"}],"post_tag":[{"value":67,"label":"\u30c8\u30e9\u30f3\u30b9\u30d5\u30a7\u30af\u30b7\u30e7\u30f3"}]},"featured_image_src_large":["https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/guidelines-and-optimizing-for-plasmid-dna-transfection-title-1024x538.jpg",760,399,true],"author_info":{"display_name":"LATB Staff","author_link":"https:\/\/admin.acceleratingscience.com\/author\/latbstaff\/"},"comment_info":0,"category_info":[{"term_id":159,"name":"\u7d30\u80de\u57f9\u990a\u30fb\u30a4\u30e1\u30fc\u30b8\u30f3\u30b0","slug":"cell","term_group":0,"term_taxonomy_id":159,"taxonomy":"category","description":"","parent":0,"count":103,"filter":"raw","meta":[],"cat_ID":159,"category_count":103,"category_description":"","cat_name":"\u7d30\u80de\u57f9\u990a\u30fb\u30a4\u30e1\u30fc\u30b8\u30f3\u30b0","category_nicename":"cell","category_parent":0}],"tag_info":[{"term_id":67,"name":"\u30c8\u30e9\u30f3\u30b9\u30d5\u30a7\u30af\u30b7\u30e7\u30f3","slug":"transfection","term_group":0,"term_taxonomy_id":67,"taxonomy":"post_tag","description":"","parent":0,"count":17,"filter":"raw","meta":[]}],"jetpack-related-posts":[{"id":23864,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/protein-expression-cloning-bid-ts-mbr-25070\/","url_meta":{"origin":569,"position":0},"title":"\u521d\u5fc3\u8005\u3067\u3082\u5b89\u5fc3\uff01\u7c21\u5358\u306b\u3067\u304d\u308b\u767a\u73fe\u30d9\u30af\u30bf\u30fc\u306e\u4f5c\u308a\u65b9\uff1a\u4eba\u5de5\u907a\u4f1d\u5b50\u5408\u6210\u30b5\u30fc\u30d3\u30b9\u306e\u5229\u7528\u6cd5","author":"LatB Staff","date":"2025\u5e7411\u670813\u65e5","format":false,"excerpt":"\u30bf\u30f3\u30d1\u30af\u8cea\u767a\u73fe\u5b9f\u9a13\u306b\u306f\u767a\u73fe\u30d9\u30af\u30bf\u30fc\u304c\u6b20\u304b\u305b\u307e\u305b\u3093\u304c\u3001\u4e00\u304b\u3089\u4f5c\u308b\u3068\u306a\u308b\u3068\u3001\u304b\u306a\u308a\u306e\u624b\u9593\u3068\u7d4c\u9a13\u304c\u5fc5\u8981\u3067\u3059\u2026","rel":"","context":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","block_context":{"text":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/mol-bio\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/10\/protein-expression-cloning-bid-ts-mbr-25070_eyecatch.png?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/10\/protein-expression-cloning-bid-ts-mbr-25070_eyecatch.png?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/10\/protein-expression-cloning-bid-ts-mbr-25070_eyecatch.png?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/10\/protein-expression-cloning-bid-ts-mbr-25070_eyecatch.png?resize=700%2C400&ssl=1 2x"},"classes":[]},{"id":25540,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/cloning-cell-separation-bid-ts-mbr-26023\/","url_meta":{"origin":569,"position":1},"title":"\u5927\u8178\u83cc\u306e\u98fc\u3044\u65b92\uff5e\u5b9f\u969b\u306b\u57f9\u990a\u3057\u3066\u307f\u3088\u3046","author":"LatB Staff","date":"2026\u5e748\u670826\u65e5","format":false,"excerpt":"\u30d6\u30ed\u30b0\u300c\u5927\u8178\u83cc\u306e\u98fc\u3044\u65b9\uff5e\u5b9f\u9a13\u306b\u5fc5\u8981\u306a\u8a2d\u5099\u3092\u305d\u308d\u3048\u3088\u3046\u300d\u3067\u306f\u3001\u30af\u30ed\u30fc\u30cb\u30f3\u30b0\u3084\u7d44\u307f\u63db\u3048\u30bf\u30f3\u30d1\u30af\u8cea\u767a\u73fe\u306e\u7528\u2026","rel":"","context":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","block_context":{"text":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/mol-bio\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/08\/cloning-cell-separation-bid-ts-mbr-26023_eyecatch.png?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/08\/cloning-cell-separation-bid-ts-mbr-26023_eyecatch.png?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/08\/cloning-cell-separation-bid-ts-mbr-26023_eyecatch.png?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/08\/cloning-cell-separation-bid-ts-mbr-26023_eyecatch.png?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/08\/cloning-cell-separation-bid-ts-mbr-26023_eyecatch.png?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/08\/cloning-cell-separation-bid-ts-mbr-26023_eyecatch.png?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":23665,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/pcr-dna-gsd-ts-tr-25064\/","url_meta":{"origin":569,"position":2},"title":"\u3010\u3084\u3063\u3066\u307f\u305f\u3011PCR\u306e\u30a2\u30cb\u30fc\u30ea\u30f3\u30b0\u6e29\u5ea6\u3092\u601d\u3044\u5207\u308a\u632f\u3063\u3066\u307f\u305f","author":"LatB Staff","date":"2025\u5e7410\u670828\u65e5","format":false,"excerpt":"\u65b0\u305f\u306aPCR\u691c\u51fa\u7cfb\u3092\u69cb\u7bc9\u3059\u308b\u5834\u5408\u3001\u4f55\u3088\u308a\u3082\u30d7\u30e9\u30a4\u30de\u30fc\u306e\u914d\u5217\u304c\u91cd\u8981\u3068\u3044\u3046\u3053\u3068\u306f\u591a\u304f\u306e\u65b9\u304c\u8a8d\u8b58\u3057\u3066\u3044\u308b\u306e\u2026","rel":"","context":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","block_context":{"text":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/mol-bio\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/10\/pcr-dna-gsd-ts-tr-25064_eyecatch-scaled.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/10\/pcr-dna-gsd-ts-tr-25064_eyecatch-scaled.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/10\/pcr-dna-gsd-ts-tr-25064_eyecatch-scaled.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/10\/pcr-dna-gsd-ts-tr-25064_eyecatch-scaled.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/10\/pcr-dna-gsd-ts-tr-25064_eyecatch-scaled.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/10\/pcr-dna-gsd-ts-tr-25064_eyecatch-scaled.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":24545,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/digital-pcr-gene-expression-gsd-ts-sd-25082\/","url_meta":{"origin":569,"position":3},"title":"\u3010Absolute Q\u30c7\u30b8\u30bf\u30ebPCR\u30b7\u30b9\u30c6\u30e0\u306e\u6d3b\u7528\u4f8b\u3011\u30df\u30c8\u30b3\u30f3\u30c9\u30ea\u30a2DNA\u306e\u5b9a\u91cf","author":"LatB Staff","date":"2026\u5e741\u670816\u65e5","format":false,"excerpt":"Applied Biosystems\u2122 QuantStudio\u2122 Absolute Q\u2122 \u30c7\u30b8\u30bf\u30ebP\u2026","rel":"","context":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","block_context":{"text":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/mol-bio\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/12\/digital-pcr-gene-expression-gsd-ts-sd-25082_eyecatch.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/12\/digital-pcr-gene-expression-gsd-ts-sd-25082_eyecatch.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/12\/digital-pcr-gene-expression-gsd-ts-sd-25082_eyecatch.jpg?resize=525%2C300&ssl=1 1.5x"},"classes":[]},{"id":24382,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/cell-imaging-fluorescent-dye-bid-ts-mbr-25075\/","url_meta":{"origin":569,"position":4},"title":"Cell Painting Assay\u3067\u7528\u3044\u3089\u308c\u308b\u8a66\u85ac\u306b\u3064\u3044\u3066 (Hoechst\u3092\u7528\u3044\u305f\u6838\u67d3\u8272\uff09","author":"LatB Staff","date":"2025\u5e7412\u670810\u65e5","format":false,"excerpt":"\u8fd1\u5e74\u3001\u30bb\u30eb\u30da\u30a4\u30f3\u30c6\u30a3\u30f3\u30b0\uff08Cell Painting\uff09\u3068\u3044\u3046\u30a2\u30c3\u30bb\u30a4\u65b9\u6cd5\u304c\u5e83\u307e\u308a\u3064\u3064\u3042\u308a\u307e\u3059\u3002\u7d30\u80de\u306b\u2026","rel":"","context":"\u7d30\u80de\u57f9\u990a\u30fb\u30a4\u30e1\u30fc\u30b8\u30f3\u30b0","block_context":{"text":"\u7d30\u80de\u57f9\u990a\u30fb\u30a4\u30e1\u30fc\u30b8\u30f3\u30b0","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/cell\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/11\/cell-imaging-fluorescent-dye-bid-ts-mbr-25075_eyecatch-scaled.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/11\/cell-imaging-fluorescent-dye-bid-ts-mbr-25075_eyecatch-scaled.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/11\/cell-imaging-fluorescent-dye-bid-ts-mbr-25075_eyecatch-scaled.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/11\/cell-imaging-fluorescent-dye-bid-ts-mbr-25075_eyecatch-scaled.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/11\/cell-imaging-fluorescent-dye-bid-ts-mbr-25075_eyecatch-scaled.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/11\/cell-imaging-fluorescent-dye-bid-ts-mbr-25075_eyecatch-scaled.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":23370,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/pcr-dna-gsd-ts-tr-25061\/","url_meta":{"origin":569,"position":5},"title":"\u3010\u3084\u3063\u3066\u307f\u305f\u3011PCR\u5f8c\u306e\u4fdd\u5b58\u6e29\u5ea6\u306f4\u2103\u4e00\u629e\u3067\u3059\u304b\uff1f\u4ed6\u306e\u6e29\u5ea6\u3082\u8a66\u3057\u3066\u307f\u305f","author":"LatB Staff","date":"2025\u5e7410\u670816\u65e5","format":false,"excerpt":"PCR\uff08\u30dd\u30ea\u30e1\u30e9\u30fc\u30bc\u9023\u9396\u53cd\u5fdc\uff09\u306f\u3001\u5206\u5b50\u751f\u7269\u5b66\u306e\u5b9f\u9a13\u306e\u6839\u5e79\u3092\u306a\u3059\u975e\u5e38\u306b\u91cd\u8981\u306a\u6280\u8853\u3067\u3059\u3002PCR\u3092\u884c\u3063\u305f\u5f8c\u2026","rel":"","context":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","block_context":{"text":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/mol-bio\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/10\/pcr-dna-gsd-ts-tr-25061_eyecatch.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/10\/pcr-dna-gsd-ts-tr-25061_eyecatch.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/10\/pcr-dna-gsd-ts-tr-25061_eyecatch.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/10\/pcr-dna-gsd-ts-tr-25061_eyecatch.jpg?resize=700%2C400&ssl=1 2x"},"classes":[]}],"jetpack_sharing_enabled":true,"amp_enabled":true,"jetpack_featured_media_url":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/guidelines-and-optimizing-for-plasmid-dna-transfection-title.jpg","_links":{"self":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/posts\/569","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/users\/988"}],"replies":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/comments?post=569"}],"version-history":[{"count":0,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/posts\/569\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/media\/2933"}],"wp:attachment":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/media?parent=569"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/categories?post=569"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/tags?post=569"},{"taxonomy":"division","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/division?post=569"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}