{"id":571,"date":"2017-02-16T00:00:00","date_gmt":"2017-02-16T00:00:00","guid":{"rendered":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/guidelines-and-optimizing-for-rna-transfection\/"},"modified":"2025-02-10T12:16:33","modified_gmt":"2025-02-10T03:16:33","slug":"guidelines-and-optimizing-for-rna-transfection","status":"publish","type":"post","link":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/guidelines-and-optimizing-for-rna-transfection\/","title":{"rendered":"RNA\u30c8\u30e9\u30f3\u30b9\u30d5\u30a7\u30af\u30b7\u30e7\u30f3\u306e\u305f\u3081\u306e\u30ac\u30a4\u30c9\u30e9\u30a4\u30f3\u3068\u6700\u9069\u5316\u65b9\u6cd5"},"content":{"rendered":"<p>RNA\u306e\u30c8\u30e9\u30f3\u30b9\u30d5\u30a7\u30af\u30b7\u30e7\u30f3\u306f\u3001RNA\u3092\u7d30\u80de\u306b\u5c0e\u5165\u3059\u308b\u305f\u3081\u306e\u53e4\u5178\u7684\u306a\u30c8\u30e9\u30f3\u30b9\u30d5\u30a7\u30af\u30b7\u30e7\u30f3\u6280\u8853\u304b\u3089\u6d3e\u751f\u3057\u3066\u3044\u307e\u3059\u3002RNA\u30c8\u30e9\u30f3\u30b9\u30d5\u30a7\u30af\u30b7\u30e7\u30f3\u306e\u76ee\u7684\u306f\u3001\u30d7\u30e9\u30b9\u30df\u30c9\u30c8\u30e9\u30f3\u30b9\u30d5\u30a7\u30af\u30b7\u30e7\u30f3\u306b\u985e\u4f3c\u3057\u307e\u3059\u3002mRNA\u304c\u7d30\u80de\u306b\u5c0e\u5165\u3055\u308c\u308b\u3068\u3001\u30b3\u30fc\u30c9\u3055\u308c\u3066\u3044\u308b\u30bf\u30f3\u30d1\u30af\u8cea\u304c\u767a\u73fe\u3055\u308c\u3001\u907a\u4f1d\u5b50\u306e\u6a5f\u80fd\u304a\u3088\u3073\u8abf\u7bc0\u306b\u95a2\u3059\u308b\u7814\u7a76\u304c\u53ef\u80fd\u3068\u306a\u308a\u307e\u3059\u3002siRNA\u306f\u3001\u907a\u4f1d\u5b50\u30ce\u30c3\u30af\u30c0\u30a6\u30f3\u306e\u52b9\u679c\u306b\u3064\u3044\u3066\u8abf\u3079\u308b\u305f\u3081\u306eRNAi\u7814\u7a76\u306b\u4f7f\u7528\u3055\u308c\u307e\u3059\u3002\u3053\u306e2\u3064\u306e\u65b9\u6cd5\u306e1\u3064\u306e\u5927\u304d\u306a\u9055\u3044\u306f\u3001RNA\u306e\u307f\u3092\u4e00\u904e\u7684\u306b\u30c8\u30e9\u30f3\u30b9\u30d5\u30a7\u30af\u30b7\u30e7\u30f3\u3067\u304d\u308b\u3053\u3068\u3067\u3059\u3002<\/p>\n<p>\u4eca\u56de\u306f\u3001<strong>RNA\u3092\u7528\u3044\u305f\u30c8\u30e9\u30f3\u30b9\u30d5\u30a7\u30af\u30b7\u30e7\u30f3\u306b\u3064\u3044\u3066\u306e\u30ac\u30a4\u30c9\u30e9\u30a4\u30f3\u3068\u30d1\u30e9\u30e1\u30fc\u30bf\u306e\u6700\u9069\u5316\u65b9\u6cd5<\/strong>\u306b\u3064\u3044\u3066\u3054\u7d39\u4ecb\u3057\u307e\u3059\u3002<\/p>\n<h2>RNA\u30c8\u30e9\u30f3\u30b9\u30d5\u30a7\u30af\u30b7\u30e7\u30f3\u306e\u305f\u3081\u306e\u30ac\u30a4\u30c9\u30e9\u30a4\u30f3<\/h2>\n<h3>RNAi\u306e\u30ef\u30fc\u30af\u30d5\u30ed\u30fc<\/h3>\n<p>siRNA\u306e\u30c7\u30b6\u30a4\u30f3\u304a\u3088\u3073\u5408\u6210\u304b\u3089\u59cb\u307e\u308bRNAi\u5b9f\u9a13\u306e\u30ef\u30fc\u30af\u30d5\u30ed\u30fc\u3092\u4e0b\u56f3\u306b\u793a\u3057\u307e\u3059\u3002\u4ee5\u4e0b\u306e\u3054\u7528\u610f\u304c\u3042\u308b\u304b\u3092\u78ba\u8a8d\u3057\u305f\u4e0a\u3067RNAi\u5b9f\u9a13\u3092\u5b9f\u65bd\u3057\u307e\u3059\u3002<\/p>\n<ul>\n<li>\u30c8\u30e9\u30f3\u30b9\u30d5\u30a7\u30af\u30b7\u30e7\u30f3\uff0f\u30a8\u30ec\u30af\u30c8\u30ed\u30dd\u30ec\u30fc\u30b7\u30e7\u30f3\u8a66\u85ac\u304a\u3088\u3073\u30d7\u30ed\u30c8\u30b3\u30fc\u30eb<\/li>\n<li>\u30ce\u30c3\u30af\u30c0\u30a6\u30f3\u304a\u3088\u3073\u4ed6\u306eRNAi\u306e\u52b9\u679c\u306b\u3064\u3044\u3066\u8a55\u4fa1\u3059\u308b\u305f\u3081\u306e\u30a2\u30c3\u30bb\u30a4<\/li>\n<li>\u30dd\u30b8\u30c6\u30a3\u30d6\u304a\u3088\u3073\u30cd\u30ac\u30c6\u30a3\u30d6\u30b3\u30f3\u30c8\u30ed\u30fc\u30ebsiRNA<\/li>\n<li>2\u3064\u4ee5\u4e0a\u306esiRNA\u306e\u76ee\u7684\u907a\u4f1d\u5b50\u3078\u306e\u5c0e\u5165<\/li>\n<\/ul>\n<div id=\"attachment_1673\" style=\"width: 871px\" class=\"wp-caption aligncenter\"><a href=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/guidelines-and-optimizing-for-rna-transfection-fig.png\" rel=\"attachment wp-att-1673\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-1673\" class=\"size-full wp-image-1673\" src=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/guidelines-and-optimizing-for-rna-transfection-fig.png\" alt=\"guidelines-and-optimizing-for-rna-transfection-fig\" width=\"861\" height=\"743\" \/><\/a><p id=\"caption-attachment-1673\" class=\"wp-caption-text\">\u56f3 siRNA\u306e\u30c7\u30b6\u30a4\u30f3\u304a\u3088\u3073\u5408\u6210\u304b\u3089\u59cb\u307e\u308bRNAi\u5b9f\u9a13\u306e\u30ef\u30fc\u30af\u30d5\u30ed\u30fc<\/p><\/div>\n<h3>RNA\u306e\u53d6\u308a\u6271\u3044<\/h3>\n<p><strong>RNA\u30aa\u30ea\u30b4\u30cc\u30af\u30ec\u30aa\u30c1\u30c9\u306f\u3001\u53d6\u308a\u6271\u3044\u4e2d\u306b\u6df7\u5165\u3057\u305f\u5916\u6765\u6027\u30ea\u30dc\u30cc\u30af\u30ec\u30a2\u30fc\u30bc\u306b\u3088\u308b\u5206\u89e3\u3092\u53d7\u3051\u3084\u3059\u3044<\/strong>\u50be\u5411\u304c\u3042\u308a\u307e\u3059\u3002<\/p>\n<ul>\n<li>RNA\u3092\u53d6\u308a\u6271\u3046\u969b\u306f\u624b\u888b\u3092\u7740\u7528\u3057\u307e\u3059\u3002<\/li>\n<li>\u30c8\u30e9\u30f3\u30b9\u30d5\u30a7\u30af\u30b7\u30e7\u30f3\u7528\u306eRNA\u3092\u8abf\u88fd\u3059\u308b\u969b\u306f\u3001RNase\u30d5\u30ea\u30fc\u306e\u8a66\u85ac\u3001\u30c1\u30e5\u30fc\u30d6\u3001\u304a\u3088\u3073\u30d0\u30ea\u30a2\u30d4\u30da\u30c3\u30c8\u30c1\u30c3\u30d7\u3092\u4f7f\u7528\u3057\u307e\u3059\u3002<\/li>\n<li>\u4f5c\u696d\u30a8\u30ea\u30a2\u306f\u300170%\u30a8\u30bf\u30ce\u30fc\u30eb\u307e\u305f\u306f<a href=\"https:\/\/www.thermofisher.com\/order\/catalog\/product\/AM9780?CID=bid_clb_tfx_r04_jp_cp0000_pjt0000_bid00000_0so_blg_op_awa_oc_s00_cc11_Social_LAB\" target=\"_blank\" rel=\"noopener noreferrer\">RNaseZap\u2122 RNase Decontamination Solution<\/a>\u306a\u3069\u306eRNase\u9664\u53bb\u6eb6\u6db2\u3092\u4f7f\u7528\u3057\u3066\u3057\u3063\u304b\u308a\u3068\u62ed\u304d\u307e\u3059\u3002<\/li>\n<\/ul>\n<h3>\u30c8\u30e9\u30f3\u30b9\u30d5\u30a7\u30af\u30b7\u30e7\u30f3\u52b9\u7387<\/h3>\n<p><strong>siRNA\u306e\u54fa\u4e73\u985e\u7d30\u80de\u3078\u306e\u30c8\u30e9\u30f3\u30b9\u30d5\u30a7\u30af\u30b7\u30e7\u30f3\u52b9\u7387\u306f\u3001\u4f7f\u7528\u3059\u308b\u7d30\u80de\u30bf\u30a4\u30d7\u304a\u3088\u3073\u30c8\u30e9\u30f3\u30b9\u30d5\u30a7\u30af\u30b7\u30e7\u30f3\u8a66\u85ac\u306b\u3088\u3063\u3066\u7570\u306a\u308a\u307e\u3059\u3002<\/strong>\u3053\u308c\u306f\u3001\u30c8\u30e9\u30f3\u30b9\u30d5\u30a7\u30af\u30b7\u30e7\u30f3\u306b\u6700\u9069\u306a\u6fc3\u5ea6\u306f\u7d4c\u9a13\u7684\u306b\u6c7a\u5b9a\u3059\u308b\u5fc5\u8981\u304c\u3042\u308b\u3053\u3068\u3092\u610f\u5473\u3057\u307e\u3059\u3002<strong>siRNA\u30c8\u30e9\u30f3\u30b9\u30d5\u30a7\u30af\u30b7\u30e7\u30f3\u52b9\u7387\u306b\u5f71\u97ff\u3092\u4e0e\u3048\u308b\u4e3b\u306a\u8981\u7d20<\/strong>\u3092\u4ee5\u4e0b\u306b\u793a\u3057\u307e\u3059\u3002<\/p>\n<ul>\n<li>\u30c8\u30e9\u30f3\u30b9\u30d5\u30a7\u30af\u30b7\u30e7\u30f3\u8a66\u85ac\u306e\u7a2e\u985e\u304a\u3088\u3073\u91cf<\/li>\n<li>\u30a6\u30a7\u30eb\u306b\u30d7\u30ec\u30fc\u30c6\u30a3\u30f3\u30b0\u3057\u305f\u7d30\u80de\u6570<\/li>\n<li>RNA\u307e\u305f\u306fsiRNA\u306e\u30bf\u30a4\u30d7<\/li>\n<li>RNA\u307e\u305f\u306fsiRNA\u306e\u6fc3\u5ea6<\/li>\n<\/ul>\n<h3>\u30dd\u30b8\u30c6\u30a3\u30d6\u30b3\u30f3\u30c8\u30ed\u30fc\u30eb<\/h3>\n<p><strong>\u30dd\u30b8\u30c6\u30a3\u30d6\u30b3\u30f3\u30c8\u30ed\u30fc\u30eb\u3092\u5b9f\u9a13\u3054\u3068\u306b\u8a2d\u5b9a\u3059\u308b\u3053\u3068\u306f\u91cd\u8981\u3067\u3059\u3002<\/strong>\u30dd\u30b8\u30c6\u30a3\u30d6\u30b3\u30f3\u30c8\u30ed\u30fc\u30eb\u306f\u3001\u518d\u73fe\u6027\u304c\u3042\u308a\u3001\u7d30\u80de\u306b\u304a\u3051\u308b\u53cd\u5fdc\u3092\u7c21\u5358\u306b\u6e2c\u5b9a\u3067\u304d\u3001\u76ee\u7684\u306e\u7814\u7a76\u306b\u304a\u3044\u3066\u4f7f\u7528\u3055\u308c\u308b\u30a2\u30c3\u30bb\u30a4\u3067\u3042\u308b\u5fc5\u8981\u304c\u3042\u308a\u307e\u3059\u3002\u6700\u5927\u52b9\u679c\u304c\u3053\u306e\u30b3\u30f3\u30c8\u30ed\u30fc\u30eb\u306e\u898f\u5b9a\u306e\u95be\u5024\u30ec\u30d9\u30eb\u524d\u5f8c\u3067\u3042\u3063\u305f\u5834\u5408\u3001\u540c\u65e5\u306b\u30c6\u30b9\u30c8\u3057\u305f\u4ed6\u306e\u5b9f\u9a13\u306b\u304a\u3051\u308b\u6e2c\u5b9a\u5024\u306f\u4fe1\u983c\u3067\u304d\u307e\u3059\u3002\u5404\u30a2\u30c3\u30bb\u30a4\u306e\u95be\u5024\u304a\u3088\u3073\u30b3\u30f3\u30c8\u30ed\u30fc\u30eb\u30da\u30a2\u306f\u7d4c\u9a13\u7684\u306b\u6c7a\u5b9a\u3059\u308b\u3053\u3068\u304c\u91cd\u8981\u3067\u3042\u308b\u3053\u3068\u306b\u306f\u7559\u610f\u3059\u308b\u5fc5\u8981\u304c\u3042\u308a\u307e\u3059\u3002<\/p>\n<p>\u7279\u5b9a\u306eRNA\u307e\u305f\u306fsiRNA\u306b\u5bfe\u3059\u308b\u53cd\u5fdc\u306e\u7a0b\u5ea6\u304c\u305d\u306e\u30c8\u30e9\u30f3\u30b9\u30d5\u30a7\u30af\u30b7\u30e7\u30f3\u52b9\u7387\u306b\u76f4\u7d50\u3057\u307e\u3059\u3002\u30c8\u30e9\u30f3\u30b9\u30d5\u30a7\u30af\u30b7\u30e7\u30f3\u52b9\u7387\u3092\u78ba\u8a8d\u3059\u308b\u305f\u3081\u306b\u306f\u3001\u5b9f\u9a13\u3054\u3068\u306b<a href=\"https:\/\/www.thermofisher.com\/order\/catalog\/product\/2013?CID=bid_clb_tfx_r04_jp_cp0000_pjt0000_bid00000_0so_blg_op_awa_oc_s00_cc11_Social_LAB\" target=\"_blank\" rel=\"noopener noreferrer\">BLOCK-iT\u2122 Fluorescent Oligo<\/a>\u3092\u4f7f\u7528\u3059\u308b\u3053\u3068\u3092\u63a8\u5968\u3057\u307e\u3059\u3002\u30c8\u30e9\u30f3\u30b9\u30d5\u30a7\u30af\u30b7\u30e7\u30f3\u5b9f\u9a13\u306b<a href=\"https:\/\/www.thermofisher.com\/order\/catalog\/product\/2013?CID=bid_clb_tfx_r04_jp_cp0000_pjt0000_bid00000_0so_blg_op_awa_oc_s00_cc11_Social_LAB\" target=\"_blank\" rel=\"noopener noreferrer\">BLOCK-iT Fluorescent Oligo<\/a>\u3092\u4f7f\u7528\u3059\u308b\u3068\u3001\u3042\u3089\u3086\u308b\u86cd\u5149\u9855\u5fae\u93e1\u304a\u3088\u3073\u6a19\u6e96\u7684\u306aFITC\u30d5\u30a3\u30eb\u30bf\u30fc\u30bb\u30c3\u30c8\u3092\u4f7f\u7528\u3057\u3066\u3001\u30aa\u30ea\u30b4\u30de\u30fc\u306e\u53d6\u308a\u8fbc\u307f\u304a\u3088\u3073\u30c8\u30e9\u30f3\u30b9\u30d5\u30a7\u30af\u30b7\u30e7\u30f3\u52b9\u7387\u3092\u7c21\u5358\u306b\u8a55\u4fa1\u3067\u304d\u307e\u3059\u3002\u86cd\u5149\u30aa\u30ea\u30b4\u30de\u30fc\u306e\u53d6\u308a\u8fbc\u307f\u7387\u304c\u5c11\u306a\u304f\u3068\u308280%\u4ee5\u4e0a\u3067\u3042\u308b\u3068\u3001\u9ad8\u52b9\u7387\u3068\u8a55\u4fa1\u3055\u308c\u307e\u3059\u3002<\/p>\n<h3>\u30cd\u30ac\u30c6\u30a3\u30d6\u30b3\u30f3\u30c8\u30ed\u30fc\u30eb<\/h3>\n<p><strong>\u30cd\u30ac\u30c6\u30a3\u30d6\u30b3\u30f3\u30c8\u30ed\u30fc\u30eb\u306f\u3001\u610f\u5473\u306e\u3042\u308b\u30c7\u30fc\u30bf\u3092\u53d6\u5f97\u3059\u308b\u305f\u3081\u306b\u30dd\u30b8\u30c6\u30a3\u30d6\u30b3\u30f3\u30c8\u30ed\u30fc\u30eb\u3068\u540c\u3058\u3088\u3046\u306b\u91cd\u8981\u3067\u3059\u3002<\/strong>\u5e38\u306b\u3001\u5c11\u306a\u304f\u3068\u30821\u7a2e\u985e\u306e\u30cd\u30ac\u30c6\u30a3\u30d6\u30b3\u30f3\u30c8\u30ed\u30fc\u30eb\u3092\u7b49\u30e2\u30eb\u91cf\u4f7f\u7528\u3057\u305f\u4e00\u9023\u306e\u30c8\u30e9\u30f3\u30b9\u30d5\u30a7\u30af\u30b7\u30e7\u30f3\u3092\u4e26\u884c\u3057\u3066\u884c\u3044\u3001\u30bf\u30fc\u30b2\u30c3\u30c8RNA\u307e\u305f\u306fsiRNA\u3067\u51e6\u7406\u3057\u305f\u7d30\u80de\u304a\u3088\u3073\u30b3\u30f3\u30c8\u30ed\u30fc\u30eb\u3067\u51e6\u7406\u3057\u305f\u7d30\u80de\u306e\u52b9\u679c\u3092\u6bd4\u8f03\u3057\u307e\u3059\u3002\u3053\u308c\u3089\u306e\u91cd\u8981\u306a\u30b3\u30f3\u30c8\u30ed\u30fc\u30eb\u304b\u3089\u5f97\u3089\u308c\u308b\u30c7\u30fc\u30bf\u306f\u3001\u5b9f\u9a13\u30bf\u30fc\u30b2\u30c3\u30c8\u306e\u30ce\u30c3\u30af\u30c0\u30a6\u30f3\u3092\u8a55\u4fa1\u3059\u308b\u305f\u3081\u306e\u30d9\u30fc\u30b9\u30e9\u30a4\u30f3\u3067\u3059\u3002<\/p>\n<p><strong>\u975e\u30c8\u30e9\u30f3\u30b9\u30d5\u30a7\u30af\u30c8\u7d30\u80de\u307e\u305f\u306f\u7d30\u80de\u306e\u307f\u306e\u30cd\u30ac\u30c6\u30a3\u30d6\u30b3\u30f3\u30c8\u30ed\u30fc\u30eb\u3082\u975e\u5e38\u306b\u6709\u7528\u3067\u3059\u3002<\/strong>\u30c8\u30e9\u30f3\u30b9\u30d5\u30a7\u30af\u30b7\u30e7\u30f3\u3057\u3066\u3044\u306a\u3044\u57f9\u990a\u3068\u975e\u30bf\u30fc\u30b2\u30c6\u30a3\u30f3\u30b0\u30cd\u30ac\u30c6\u30a3\u30d6\u30b3\u30f3\u30c8\u30ed\u30fc\u30eb\u3092\u30c8\u30e9\u30f3\u30b9\u30d5\u30a7\u30af\u30b7\u30e7\u30f3\u3057\u305f\u57f9\u990a\u306b\u304a\u3051\u308b\u30cf\u30a6\u30b9\u30ad\u30fc\u30d4\u30f3\u30b0\u907a\u4f1d\u5b50\u306e\u767a\u73fe\u3092\u6bd4\u8f03\u3059\u308b\u3053\u3068\u306b\u3088\u308a\u3001\u30c8\u30e9\u30f3\u30b9\u30d5\u30a7\u30af\u30b7\u30e7\u30f3\u306e\u7d30\u80de\u751f\u5b58\u7387\u3078\u306e\u5f71\u97ff\u306b\u95a2\u3059\u308b\u6709\u76ca\u306a\u60c5\u5831\u3092\u5f97\u308b\u3053\u3068\u304c\u3067\u304d\u307e\u3059\u3002<\/p>\n<table>\n<caption>\u8868 \u30b3\u30f3\u30c8\u30ed\u30fc\u30eb\u306e\u30bf\u30a4\u30d7\u3068\u63a8\u5968\u7528\u9014<\/caption>\n<tbody>\n<tr>\n<td style=\"text-align: center\">\u30b3\u30f3\u30c8\u30ed\u30fc\u30eb\u306e\u30bf\u30a4\u30d7<\/td>\n<td style=\"text-align: center\">\u63a8\u5968\u7528\u9014<\/td>\n<td style=\"text-align: center\">\u63a8\u5968\u88fd\u54c1<\/td>\n<\/tr>\n<tr>\n<td>\u30c8\u30e9\u30f3\u30b9\u30d5\u30a7\u30af\u30b7\u30e7\u30f3\u30b3\u30f3\u30c8\u30ed\u30fc\u30eb<\/td>\n<td>\u86cd\u5149\u306b\u3088\u308b\u30c8\u30e9\u30f3\u30b9\u30d5\u30a7\u30af\u30b7\u30e7\u30f3\u52b9\u7387\u306e\u7b97\u51fa\u304a\u3088\u3073\u30e2\u30cb\u30bf\u30fc<\/td>\n<td>\n<ul>\n<li><a href=\"https:\/\/www.thermofisher.com\/order\/catalog\/product\/14750100?CID=bid_clb_tfx_r04_jp_cp0000_pjt0000_bid00000_0so_blg_op_awa_oc_s00_cc11_Social_LAB\" target=\"_blank\" rel=\"noopener noreferrer\">BLOCK-iT Alexa Fluor Red Fluorescent Control<\/a><\/li>\n<li><a href=\"https:\/\/www.thermofisher.com\/order\/catalog\/product\/2013?CID=bid_clb_tfx_r04_jp_cp0000_pjt0000_bid00000_0so_blg_op_awa_oc_s00_cc11_Social_LAB\" target=\"_blank\" rel=\"noopener noreferrer\">BLOCK-iT Fluorescent Oligo<\/a><\/li>\n<\/ul>\n<\/td>\n<\/tr>\n<tr>\n<td>\u00a0\u30cd\u30ac\u30c6\u30a3\u30d6\u30b3\u30f3\u30c8\u30ed\u30fc\u30eb<\/td>\n<td>\u00a0\u30d0\u30c3\u30af\u30b0\u30e9\u30a6\u30f3\u30c9\u306b\u5bfe\u3059\u308b\u30ce\u30c3\u30af\u30c0\u30a6\u30f3\u30ec\u30d9\u30eb\u3092\u6e2c\u5b9a\u3059\u308b\u305f\u3081\u306e\u975e\u7279\u7570\u7684\u307e\u305f\u306f\u30b9\u30af\u30e9\u30f3\u30d6\u30eb\u30b3\u30f3\u30c8\u30ed\u30fc\u30eb<\/td>\n<td>\n<ul>\n<li><a href=\"https:\/\/www.thermofisher.com\/order\/catalog\/product\/4390843?CID=bid_clb_tfx_r04_jp_cp0000_pjt0000_bid00000_0so_blg_op_awa_oc_s00_cc11_Social_LAB\" target=\"_blank\" rel=\"noopener noreferrer\">Silencer Select Negative Control siRNAs<\/a><\/li>\n<li><a href=\"https:\/\/www.thermofisher.com\/order\/catalog\/product\/12935100?CID=bid_clb_tfx_r04_jp_cp0000_pjt0000_bid00000_0so_blg_op_awa_oc_s00_cc11_Social_LAB\" target=\"_blank\" rel=\"noopener noreferrer\">Stealth RNAi siRNA\u30cd\u30ac\u30c6\u30a3\u30d6\u30b3\u30f3\u30c8\u30ed\u30fc\u30eb<\/a><\/li>\n<li><a href=\"https:\/\/www.thermofisher.com\/order\/catalog\/product\/AM4611?CID=bid_clb_tfx_r04_jp_cp0000_pjt0000_bid00000_0so_blg_op_awa_oc_s00_cc11_Social_LAB\" target=\"_blank\" rel=\"noopener noreferrer\">Silencer negative control siRNAs<\/a><\/li>\n<\/ul>\n<\/td>\n<\/tr>\n<tr>\n<td>\u30dd\u30b8\u30c6\u30a3\u30d6\u30b3\u30f3\u30c8\u30ed\u30fc\u30eb<\/td>\n<td>\u9ad8\u30ec\u30d9\u30eb\u3067\u30ce\u30c3\u30af\u30c0\u30a6\u30f3\u3092\u9054\u6210\u3059\u308b\u3053\u3068\u3067\u77e5\u3089\u308c\u308bRNAi\u8a66\u85ac\u306e\u4f7f\u7528\u306b\u3088\u308b\u5c0e\u5165\u52b9\u7387\u306e\u30e2\u30cb\u30bf\u30fc\u304a\u3088\u3073\u5b9f\u9a13\u6761\u4ef6\u306e\u6700\u9069\u5316<\/td>\n<td>\n<ul>\n<li><a href=\"https:\/\/www.thermofisher.com\/order\/catalog\/product\/4390849?CID=bid_clb_tfx_r04_jp_cp0000_pjt0000_bid00000_0so_blg_op_awa_oc_s00_cc11_Social_LAB\" target=\"_blank\" rel=\"noopener noreferrer\">Silencer Select GAPDH Positive Control siRNA<\/a><\/li>\n<li><a href=\"http:\/\/www.thermofisher.com\/order\/catalog\/ja\/JP\/adirect\/lt?cmd=catDisplayStyle&amp;_bcs_=H4sIAAAAAAAAANVTXU%2BDMBT9NX2RuJTWVniEIcaPzMUZX5cGyqgpYymdC%2F%2FeW1j92mZ88cGkuff0%0AcD9yTsN5iHA0N225LWwXIMKDhTSvqpDdD3xt7QbRBJEczm63m9hamqatVAd5UrQN0NsOglxDqNtG%0AQmpNCR9r22iYgAh1B0fWbKW740sMKcQhVMb0Aodnjr2iKCIojT3IB0BRSvcgwp6ZemYsxigK90wS%0AHyvOXYy4n0wPJke%2BPfu%2BIkl%2F5QFNYOFeN%2BRCWKHbFaAXAeF2DkGUysjCAtIW0bxoSkSzm%2BfrGRRn%0Aqtto0U%2BFlavW9PAEQN7JHioGgz67WAndHbfRZca8nQzFeFDGXYzx4yxR%2F9MBp%2BmEA46v7DLkg%2Fpq%0AyVg06l9YKbStg0E14daIUiKaBp0C5k8FfYhZ2F7D38DddcQ0W6j1Sst7%2BSr1aa2EP8zhUilt3W4%2B%0AAjdmJpphyqgOkXTUx7xCwmgK7KjSNz71G9cUvhNutjeNfbHtwOM3b4fgTjQEAAA%3D&amp;?CID=bid_clb_tfx_r04_jp_cp0000_pjt0000_bid00000_0so_blg_op_awa_oc_s00_cc11_Social_LAB\" target=\"_blank\" rel=\"noopener noreferrer\">Stealth RNAi siRNA\u30dd\u30b8\u30c6\u30a3\u30d6\u30b3\u30f3\u30c8\u30ed\u30fc\u30eb<\/a><\/li>\n<li><a href=\"https:\/\/www.thermofisher.com\/order\/catalog\/product\/4404025?CID=bid_clb_tfx_r04_jp_cp0000_pjt0000_bid00000_0so_blg_op_awa_oc_s00_cc11_Social_LAB\" target=\"_blank\" rel=\"noopener noreferrer\">Silencer positive control siRNA<\/a><\/li>\n<\/ul>\n<\/td>\n<\/tr>\n<tr>\n<td>\u975e\u5c0e\u5165\u30b3\u30f3\u30c8\u30ed\u30fc\u30eb<\/td>\n<td>\u6b63\u5e38\u907a\u4f1d\u5b50\u767a\u73fe\u30ec\u30d9\u30eb\u304a\u3088\u3073\u8868\u73fe\u578b\u306e\u6e2c\u5b9a<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\u540c\u4e00\u30bf\u30fc\u30b2\u30c3\u30c8\u306b\u5bfe\u3059\u308b\u8907\u6570\u306eRNAi\u914d\u5217<\/td>\n<td>\u8868\u73fe\u578b\u5909\u5316\u306e\u78ba\u8a8d\u3001publication quality\u306e\u7d50\u679c\u3092\u7372\u5f97\u3059\u308b\u305f\u3081\u306e\u30aa\u30d5\u30bf\u30fc\u30b2\u30c3\u30c8\u52b9\u679c\u306e\u30b3\u30f3\u30c8\u30ed\u30fc\u30eb\u306b\u4f7f\u7528<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>RNAi\u306e\u6ef4\u5b9a<\/td>\n<td>\u7d30\u80de\u306e\u6b63\u5e38\u30d7\u30ed\u30bb\u30b9\u306e\u5909\u5316\u3092\u56de\u907f\u3059\u308b\u6700\u4f4e\u6709\u52b9\u6fc3\u5ea6\u3067\u306e\u4f7f\u7528<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\u30ec\u30b9\u30ad\u30e5\u30fc\u5b9f\u9a13<\/td>\n<td>\u8a98\u5c0eRNAi\u306e\u89e3\u9664\u307e\u305f\u306fRNAi\u914d\u5217\u304c\u5f71\u97ff\u3057\u306a\u3044\u6a19\u7684mRNA\u3092\u767a\u73fe\u3059\u308b\u30d7\u30e9\u30b9\u30df\u30c9\u306e\u5c0e\u5165<\/td>\n<td><a href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/life-science\/rnai\/vector-based-rnai\/pol-ii-mir-rnai-vectors.html?CID=bid_clb_tfx_r04_jp_cp0000_pjt0000_bid00000_0so_blg_op_awa_oc_s00_cc11_Social_LAB\" target=\"_blank\" rel=\"noopener noreferrer\">BLOCK-iT Pol II miR RNAi<\/a>\u307e\u305f\u306f<a href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/life-science\/rnai\/vector-based-rnai\/shrna-vectors.html?CID=bid_clb_tfx_r04_jp_cp0000_pjt0000_bid00000_0so_blg_op_awa_oc_s00_cc11_Social_LAB\" target=\"_blank\" rel=\"noopener noreferrer\">BLOCK-iT shRNA\u30d9\u30af\u30bf\u30fc<\/a>\uff0b\u8a98\u5c0e\u6027\u30d7\u30ed\u30e2\u30fc\u30bf\u30fc\uff08\u305d\u308c\u305e\u308cCMV\/TO\u304a\u3088\u3073H1\/TO\uff09<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h3>\u30b3\u30c8\u30e9\u30f3\u30b9\u30d5\u30a7\u30af\u30b7\u30e7\u30f3<\/h3>\n<p><strong>\u30b3\u30c8\u30e9\u30f3\u30b9\u30d5\u30a7\u30af\u30b7\u30e7\u30f3\u306f\u3001siRNA\u3068\u30bf\u30f3\u30d1\u30af\u8cea\u3092\u767a\u73fe\u3055\u305b\u308b\u305f\u3081\u306e\u30d7\u30e9\u30b9\u30df\u30c9\u3092\u540c\u6642\u306b\u7d30\u80de\u306b\u5c0e\u5165\u3059\u308b\u969b\u306b\u5b9f\u65bd\u3055\u308c\u307e\u3059\u3002<\/strong>\u3053\u306e\u30bf\u30f3\u30d1\u30af\u8cea\u306f\u8a66\u9a13\u30b7\u30b9\u30c6\u30e0\u306e\u4e00\u90e8\u3001\u307e\u305f\u306f\u307b\u3068\u3093\u3069\u306e\u30b1\u30fc\u30b9\u306b\u304a\u3044\u3066\u5b58\u5728\u3057\u3001\u30ec\u30dd\u30fc\u30bf\u30fc\u907a\u4f1d\u5b50\uff08\u30eb\u30b7\u30d5\u30a7\u30e9\u30fc\u30bc\u3001GFP\u3001\u03b2-\u30e9\u30af\u30bf\u30de\u30fc\u30bc\uff09\u3067\u3082\u3042\u308a\u5f97\u307e\u3059\u3002\u30b1\u30fc\u30b9\u306b\u3088\u3063\u3066\u306f\u3001siRNA\u3068\u3068\u3082\u306b\u5909\u7570\u30bf\u30f3\u30d1\u30af\u8cea\u3092\u767a\u73fe\u3055\u305b\u3066\u3001siRNA\u306e1\u3064\u306e\u30d1\u30b9\u30a6\u30a7\u30a4\u3092\u30d6\u30ed\u30c3\u30af\u3057\u3001\u5909\u7570\u30bf\u30f3\u30d1\u30af\u8cea\u3092\u904e\u5270\u767a\u73fe\u3055\u305b\u308b\u3053\u3068\u304c\u671b\u307e\u308c\u307e\u3059\u3002<\/p>\n<p>\u8102\u8cea\u30c8\u30e9\u30f3\u30b9\u30d5\u30a7\u30af\u30b7\u30e7\u30f3\u8a66\u85ac\u3092\u4f7f\u7528\u3059\u308b\u5834\u5408\u3001\u30d7\u30e9\u30b9\u30df\u30c9\u306e\u5b58\u5728\u306f\u5168\u3066\u306e\u30ab\u30fc\u30b4\uff08\u30d7\u30e9\u30b9\u30df\u30c9\u304a\u3088\u3073siRNA\uff09\u306e\u30c8\u30e9\u30f3\u30b9\u30d5\u30a7\u30af\u30b7\u30e7\u30f3\u52b9\u7387\u3092\u4f4e\u4e0b\u3055\u305b\u308b\u53ef\u80fd\u6027\u304c\u3042\u308b\u305f\u3081\u3001\u30c8\u30e9\u30f3\u30b9\u30d5\u30a7\u30af\u30b7\u30e7\u30f3\u306e\u6700\u9069\u5316\u306f\u975e\u5e38\u306b\u91cd\u8981\u3067\u3059\u3002\u8102\u8cea\u304c\u591a\u904e\u304e\u308b\u5834\u5408\u3001\u671b\u307e\u308c\u306a\u3044\u3001\u975e\u7279\u7570\u7684\u306a\u7d30\u80de\u6b7b\u304c\u751f\u3058\u308b\u53ef\u80fd\u6027\u304c\u3042\u308a\u307e\u3059\u3002\u3042\u308b\u3044\u306f\u3001\u30c8\u30e9\u30f3\u30b9\u30d5\u30a7\u30af\u30b7\u30e7\u30f3\u6761\u4ef6\u304c\u6700\u9069\u3067\u306a\u3044\u5834\u5408\u3001\u30ce\u30c3\u30af\u30c0\u30a6\u30f3\u52b9\u7387\u304c\u4f4e\u904e\u304e\u305f\u308a\u3001\u30d7\u30e9\u30b9\u30df\u30c9\u7531\u6765\u306e\u30bf\u30f3\u30d1\u30af\u8cea\u767a\u73fe\u304c\u751f\u3058\u308b\u53ef\u80fd\u6027\u304c\u3042\u308a\u307e\u3059\u3002<\/p>\n<h3>siRNA\u306e\u54c1\u8cea<\/h3>\n<p><strong>siRNA\u306e\u54c1\u8cea\u306fRNAi\u5b9f\u9a13\u306b\u8457\u3057\u304f\u5f71\u97ff\u3092\u53ca\u307c\u3057\u307e\u3059\u3002<\/strong>siRNA\u306b\u306f\u3001\u5408\u6210\u306e\u969b\u306b\u4f7f\u7528\u3055\u308c\u308b\u30a8\u30bf\u30ce\u30fc\u30eb\u3001\u5869\u3001\u304a\u3088\u3073\u30bf\u30f3\u30d1\u30af\u8cea\u306a\u3069\u306e\u8a66\u85ac\u304c\u30ad\u30e3\u30ea\u30fc\u30aa\u30fc\u30d0\u30fc\u3055\u308c\u306a\u3044\u3088\u3046\u306b\u3059\u308b\u5fc5\u8981\u304c\u3042\u308a\u307e\u3059\u3002\u307e\u305f\u300130 bp\u3088\u308a\u9577\u3044dsRNA\u593e\u96d1\u7269\u306f\u3001\u975e\u7279\u7570\u7684\u30a4\u30f3\u30bf\u30fc\u30d5\u30a7\u30ed\u30f3\u5fdc\u7b54\u3092\u6d3b\u6027\u5316\u3057\u3001\u7d30\u80de\u6bd2\u6027\u3092\u5f15\u304d\u8d77\u3053\u3059\u3053\u3068\u306b\u3088\u308a\u907a\u4f1d\u5b50\u767a\u73fe\u3092\u5909\u5316\u3055\u305b\u308b\u3053\u3068\u304c\u77e5\u3089\u308c\u3066\u3044\u307e\u3059\uff08Stark et al., 1998\uff09\u3002\u3053\u306e\u305f\u3081\u300180%\u4ee5\u4e0a\u306e\u5b8c\u5168\u9577\u306e\u6a19\u6e96\u7d14\u5ea6\u306esiRNA\u3092\u4f7f\u7528\u3059\u308b\u3053\u3068\u3092\u63a8\u5968\u3057\u307e\u3059\u3002<\/p>\n<h4>siRNA\u306e\u4fdd\u5b58<\/h4>\n<p><strong>siRNA\u306f \u201320\u00b0C\u307e\u305f\u306f \u201380\u00b0C\u306b\u8a2d\u5b9a\u3055\u308c\u305f\u30d5\u30ea\u30fc\u30b6\u30fc\u3067\u3001\u971c\u304c\u3064\u304b\u306a\u3044\u72b6\u614b\u3067\u4fdd\u5b58\u3057\u307e\u3059\u3002<\/strong>\u5f0a\u793e\u306e\u30c7\u30fc\u30bf\u3067\u306f\u300150\u56de\u306e\u51cd\u7d50\u878d\u89e3\u30b5\u30a4\u30af\u30eb\u3067\u306f\u3001100 \u03bcM\u6eb6\u6db2\u306esiRNA\u306f\u640d\u50b7\u3057\u306a\u3044\u3053\u3068\u304c\u793a\u3055\u308c\u3066\u3044\u307e\u3059\uff08\u8cea\u91cf\u30b9\u30da\u30af\u30c8\u30eb\u304a\u3088\u3073\u5206\u6790HPLC\u306b\u3088\u308b\u8a55\u4fa1\u306b\u304a\u3044\u3066\uff09\u3002\u3057\u304b\u3057\u3001\u6c5a\u67d3\u306e\u53ef\u80fd\u6027\u3092\u56de\u907f\u3059\u308b\u305f\u3081\u306b\u3001siRNA\u306f\u3001RNase\u30d5\u30ea\u30fc\u306e\u6c34\u307e\u305f\u306f\u30d0\u30c3\u30d5\u30a1\u30fc\u306b\u518d\u61f8\u6fc1\u3057\u3001\u5c0f\u5206\u3051\u5206\u6ce8\u3057\u3066\u4fdd\u5b58\u3059\u308b\u3053\u3068\u3092\u304a\u85a6\u3081\u3057\u307e\u3059\u3002<\/p>\n<h4>siRNA\u306e\u30cc\u30af\u30ec\u30a2\u30fc\u30bc\u306b\u5bfe\u3059\u308b\u5b89\u5b9a\u6027<\/h4>\n<p><strong>\u30a2\u30cb\u30fc\u30eb\u3057\u3001\u5f62\u6210\u3055\u308c\u305f\u4e8c\u672c\u9396siRNA\u306f\u3001\u4e00\u672c\u9396RNA\u3088\u308a\u3082\u30cc\u30af\u30ec\u30a2\u30fc\u30bc\u5206\u89e3\u306b\u5bfe\u3059\u308b\u5b89\u5b9a\u6027\u304c\u5411\u4e0a\u3057\u3066\u3044\u307e\u3059\u3002<\/strong>\u3057\u304b\u3057\u3001RNAi\u5b9f\u9a13\u306f\u3001\u5168\u30d7\u30ed\u30bb\u30b9\u306b\u304a\u3044\u3066\u53b3\u683c\u306aRNase\u30d5\u30ea\u30fc\u306e\u624b\u6cd5\u3067\u884c\u3046\u5fc5\u8981\u304c\u3042\u308a\u307e\u3059\u3002<\/p>\n<h4>siRNA\u5206\u89e3\u306e\u78ba\u8a8d<\/h4>\n<p><strong>siRNA\u8abf\u88fd\u7269\u306e\u5206\u89e3\u304c\u7591\u308f\u308c\u308b\u5834\u5408\u3001\u7d042.5 \u03bcg\u3092\u975e\u5909\u602715\u201320%\u30a2\u30af\u30ea\u30eb\u30a2\u30df\u30c9\u30b2\u30eb\u4e0a\u3067\u96fb\u6c17\u6cf3\u52d5\u3059\u308b\u3053\u3068\u306b\u3088\u3063\u3066siRNA\u306e\u5b8c\u5168\u6027\u3092\u78ba\u8a8d\u3057\u307e\u3059\u3002<\/strong>RNA\u3092\u30a8\u30c1\u30b8\u30a6\u30e0\u30d6\u30ed\u30de\u30a4\u30c9\u3067\u67d3\u8272\u3057\u3066\u53ef\u8996\u5316\u3057\u3001\u4e88\u6e2c\u3055\u308c\u308b\u30b5\u30a4\u30ba\u304a\u3088\u3073\u5b8c\u5168\u6027\u3092\u78ba\u8a8d\u3057\u307e\u3059\u3002siRNA\u306f\u30bf\u30a4\u30c8\u306a\u30d0\u30f3\u30c9\u3068\u3057\u3066\u79fb\u52d5\u3059\u308b\u3053\u3068\u304c\u671b\u307e\u308c\u3001\u30b9\u30e1\u30a2\u306a\u30d0\u30f3\u30c9\u304c\u8a8d\u3081\u3089\u308c\u308b\u5834\u5408\u306f\u5206\u89e3\u3057\u3066\u3044\u308b\u53ef\u80fd\u6027\u304c\u3042\u308a\u307e\u3059\u3002<\/p>\n<h3>siRNA\u306e\u91cf<\/h3>\n<p>siRNA\u306e\u6700\u9069\u91cf\u304a\u3088\u3073\u907a\u4f1d\u5b50\u30b5\u30a4\u30ec\u30f3\u30b7\u30f3\u30b0\u306e\u305f\u3081\u306e\u80fd\u529b\u306f\u3001mRNA\u306e\u5c40\u5728\u5316\u3001\u5b89\u5b9a\u6027\u3001\u5b58\u5728\u91cf\u3001\u306a\u3089\u3073\u306b\u6a19\u7684\u30bf\u30f3\u30d1\u30af\u8cea\u306e\u5b89\u5b9a\u6027\u304a\u3088\u3073\u5b58\u5728\u91cf\u3092\u542b\u3080\u3001\u30bf\u30fc\u30b2\u30c3\u30c8\u907a\u4f1d\u5b50\u7523\u7269\u306e\u7279\u6027\u306e\u5f71\u97ff\u3092\u90e8\u5206\u7684\u306b\u53d7\u3051\u307e\u3059\u3002<\/p>\n<p>\u591a\u304f\u306esiRNA\u5b9f\u9a13\u306f\u3001\u73fe\u5728\u3082100 nM\u306esiRNA\u3092\u7d30\u80de\u306b\u30c8\u30e9\u30f3\u30b9\u30d5\u30a7\u30af\u30b7\u30e7\u30f3\u3055\u305b\u308b\u3053\u3068\u306b\u3088\u308a\u884c\u308f\u308c\u3066\u3044\u307e\u3059\u304c\u3001siRNA\u3092\u3088\u308a\u4f4e\u6fc3\u5ea6\u3067\u30c8\u30e9\u30f3\u30b9\u30d5\u30a7\u30af\u30b7\u30e7\u30f3\u3055\u305b\u308b\u3068\u3001siRNA\u306b\u3088\u308a\u751f\u3058\u308b\u30aa\u30d5\u30bf\u30fc\u30b2\u30c3\u30c8\u52b9\u679c\u3092\u4f4e\u6e1b\u3067\u304d\u308b\u3068\u3044\u3046\u7d50\u679c\u304c\u5831\u544a\u3055\u308c\u3066\u3044\u307e\u3059\uff08Jackson et al., 2003; Semizarov et al., 2003\uff09\u3002\u8102\u8cea\u5a92\u4ecb\u6027\u30ea\u30d0\u30fc\u30b9\u30c8\u30e9\u30f3\u30b9\u30d5\u30a7\u30af\u30b7\u30e7\u30f3\u3067\u306f\u300110 nM\u306esiRNA\uff081\uff5e30 nM\u306e\u7bc4\u56f2\uff09\u3067\u901a\u5e38\u5341\u5206\u3068\u3055\u308c\u307e\u3059\u3002\u30a8\u30ec\u30af\u30c8\u30ed\u30dd\u30ec\u30fc\u30b7\u30e7\u30f3\u3092\u7528\u3044\u308bsiRNA\u5c0e\u5165\u3067\u306f\u3001siRNA\u91cf\u306e\u5f71\u97ff\u306f\u4f4e\u3044\u3068\u8a00\u308f\u308c\u3066\u3044\u307e\u3059\u304c\u3001\u901a\u5e381 \u03bcg\/50 \u03bcL\u7d30\u80de\uff081.5 \u03bcM\uff09\u306esiRNA\uff080.5\uff5e2.5 \u03bcg\/50 \u03bcL\u7d30\u80de\u307e\u305f\u306f0.75\uff5e3.75 \u03bcM\u306e\u7bc4\u56f2\uff09\u3067\u5341\u5206\u3068\u3055\u308c\u307e\u3059\u3002<\/p>\n<p><strong>siRNA\u6fc3\u5ea6\u304c\u9ad8\u904e\u304e\u308b\u3068\u30aa\u30d5\u30bf\u30fc\u30b2\u30c3\u30c8\u3084\u7d30\u80de\u6bd2\u6027\u306b\u3064\u306a\u304c\u308a\u3001siRNA\u6fc3\u5ea6\u304c\u4f4e\u904e\u304e\u308b\u3068\u6a19\u7684\u907a\u4f1d\u5b50\u306e\u767a\u73fe\u52b9\u7387\u304c\u4f4e\u4e0b\u3059\u308b\u3053\u3068\u306b\u306f\u7559\u610f\u3059\u308b\u5fc5\u8981\u304c\u3042\u308a\u307e\u3059\u3002<\/strong>\u975e\u5e38\u306b\u591a\u304f\u306e\u5909\u6570\u304c\u95a2\u4e0e\u3059\u308b\u305f\u3081\u3001\u4f7f\u7528\u3059\u308b\u7d30\u80de\u7cfb\u3054\u3068\u306bsiRNA\u91cf\u3092\u6700\u9069\u5316\u3059\u308b\u3053\u3068\u304c\u91cd\u8981\u3067\u3059\u3002\u307e\u305f\u3001\u975e\u30bf\u30fc\u30b2\u30c6\u30a3\u30f3\u30b0\u30cd\u30ac\u30c6\u30a3\u30d6\u30b3\u30f3\u30c8\u30ed\u30fc\u30ebsiRNA\u306e\u91cf\u306f\u3001\u5b9f\u9a13\u306b\u4f7f\u7528\u3059\u308bsiRNA\u3068\u540c\u91cf\u306b\u3059\u308b\u5fc5\u8981\u304c\u3042\u308a\u307e\u3059\u3002<\/p>\n<h3>\u30c8\u30e9\u30f3\u30b9\u30d5\u30a7\u30af\u30b7\u30e7\u30f3\u8a66\u85ac\u306e\u91cf<\/h3>\n<p><strong>\u30c8\u30e9\u30f3\u30b9\u30d5\u30a7\u30af\u30b7\u30e7\u30f3\u8a66\u85ac\u306e\u91cf\u306f\u3001\u5c11\u306a\u904e\u304e\u308b\u3068\u30c8\u30e9\u30f3\u30b9\u30d5\u30a7\u30af\u30b7\u30e7\u30f3\u304c\u5236\u9650\u3055\u308c\u3001\u591a\u904e\u304e\u308b\u3068\u6bd2\u6027\u3092\u793a\u3059\u3053\u3068\u304b\u3089\u3001\u6700\u9069\u5316\u3059\u3079\u304d\u6975\u3081\u3066\u91cd\u8981\u306a\u30d1\u30e9\u30e1\u30fc\u30bf\u3067\u3059\u3002<\/strong>\u5168\u30c8\u30e9\u30f3\u30b9\u30d5\u30a7\u30af\u30b7\u30e7\u30f3\u52b9\u7387\u306f\u3001siRNA\u3068\u8907\u5408\u4f53\u3092\u5f62\u6210\u3057\u305f\u30c8\u30e9\u30f3\u30b9\u30d5\u30a7\u30af\u30b7\u30e7\u30f3\u8a66\u85ac\u306e\u91cf\u306b\u5f71\u97ff\u3055\u308c\u307e\u3059\u3002\u6700\u9069\u5316\u3059\u308b\u305f\u3081\u306b\u306f\u3001\u30c8\u30e9\u30f3\u30b9\u30d5\u30a7\u30af\u30b7\u30e7\u30f3\u8a66\u85ac\u3092\u5e45\u5e83\u3044\u5e0c\u91c8\u7bc4\u56f2\u3067\u6fc3\u5ea6\u8a2d\u5b9a\u3057\u3001\u907a\u4f1d\u5b50\u30ce\u30c3\u30af\u30c0\u30a6\u30f3\u3092\u884c\u3048\u308b\u6700\u5c0f\u6fc3\u5ea6\u3092\u9078\u629e\u3057\u307e\u3059\u3002\u3053\u306e\u5883\u754c\u6fc3\u5ea6\u306f\u3001\u7d30\u80de\u3054\u3068\u306b\u7d4c\u9a13\u7684\u306b\u6c7a\u5b9a\u3059\u308b\u5fc5\u8981\u304c\u3042\u308a\u307e\u3059\u3002<\/p>\n<h3>\u7d30\u80de\u5bc6\u5ea6<\/h3>\n<p><strong>\u7d30\u80de\u5bc6\u5ea6\u306f\u3001\u7d30\u80de\u3092\u30d7\u30ec\u30fc\u30c6\u30a3\u30f3\u30b0\u3057\u3066\u304b\u3089\u30c8\u30e9\u30f3\u30b9\u30d5\u30a7\u30af\u30b7\u30e7\u30f3\u3059\u308b\u5f93\u6765\u306e\u65b9\u6cd5\u3067\u306f\u91cd\u8981\u3067\u3059\u304c\u3001\u30ea\u30d0\u30fc\u30b9\u30c8\u30e9\u30f3\u30b9\u30d5\u30a7\u30af\u30b7\u30e7\u30f3\u306b\u3088\u308asiRNA\u3092\u7d30\u80de\u306b\u5c0e\u5165\u3059\u308b\u5834\u5408\u306f\u305d\u308c\u307b\u3069\u91cd\u8981\u3067\u306a\u304f\u3001\u6700\u9069\u5316\u306f\u307b\u3068\u3093\u3069\u307e\u305f\u306f\u5168\u304f\u5fc5\u8981\u3042\u308a\u307e\u305b\u3093\u3002<\/strong>\u3057\u304b\u3057\u3001\u975e\u5e38\u306b\u591a\u304f\u306e\u7d30\u80de\u3092\u4f7f\u7528\u3057\u3001siRNA\u91cf\u304c\u6bd4\u4f8b\u7684\u306b\u5897\u52a0\u3057\u306a\u3044\u5834\u5408\u306f\u3001\u30b5\u30f3\u30d7\u30eb\u4e2d\u306esiRNA\u6fc3\u5ea6\u304c\u907a\u4f1d\u5b50\u30b5\u30a4\u30ec\u30f3\u30b7\u30f3\u30b0\u3092\u52b9\u7387\u7684\u306b\u8a98\u767a\u3059\u308b\u306e\u306b\u4f4e\u904e\u304e\u308b\u53ef\u80fd\u6027\u304c\u3042\u308a\u307e\u3059\u3002\u7d30\u80de\u5bc6\u5ea6\u304c\u4f4e\u904e\u304e\u308b\u5834\u5408\u306f\u3001\u57f9\u990a\u304c\u4e0d\u5b89\u5b9a\u306b\u306a\u308b\u53ef\u80fd\u6027\u304c\u3042\u308a\u307e\u3059\u3002\u30de\u30eb\u30c1\u30a6\u30a7\u30eb\u30d7\u30ec\u30fc\u30c8\u5168\u4f53\u306e\u57f9\u990a\u6761\u4ef6\uff08\u4f8b\u3048\u3070\u3001pH\u3001\u6e29\u5ea6\uff09\u306f\u4e00\u5b9a\u3067\u306a\u304f\u3001\u57f9\u990a\u306b\u4e0e\u3048\u308b\u4e0d\u5b89\u5b9a\u3055\u306e\u5f71\u97ff\u3082\u7570\u306a\u308b\u305f\u3081\u3001\u4e0d\u5b89\u5b9a\u3055\u306f\u30a6\u30a7\u30eb\u306b\u3088\u3063\u3066\u7570\u306a\u308b\u53ef\u80fd\u6027\u304c\u3042\u308a\u307e\u3059\u3002<\/p>\n<h3>\u30c8\u30e9\u30f3\u30b9\u30d5\u30a7\u30af\u30b7\u30e7\u30f3\u8a66\u85ac\u3078\u306e\u66dd\u9732\/siRNA\u8907\u5408\u4f53<\/h3>\n<p>\u5927\u90e8\u5206\u306e\u30c8\u30e9\u30f3\u30b9\u30d5\u30a7\u30af\u30b7\u30e7\u30f3\u8a66\u85ac\u306f\u7d30\u80de\u6bd2\u6027\u304c\u6700\u5c0f\u9650\u306b\u306a\u308b\u3088\u3046\u306b\u30c7\u30b6\u30a4\u30f3\u3055\u308c\u3066\u3044\u307e\u3059\u304c\u3001<strong>\u7d30\u80de\u3092\u66dd\u9732\u3059\u308b\u30c8\u30e9\u30f3\u30b9\u30d5\u30a7\u30af\u30b7\u30e7\u30f3\u8a66\u85ac\u304c\u591a\u3059\u304e\u308b\u3001\u3042\u308b\u3044\u306f\u66dd\u9732\u304c\u9577\u6642\u9593\u3067\u3042\u308b\u3068\u3001\u7d30\u80de\u57f9\u990a\u306e\u5168\u822c\u7684\u306a\u5065\u5168\u6027\u304c\u640d\u306a\u308f\u308c\u308b\u53ef\u80fd\u6027\u304c\u3042\u308a\u307e\u3059\u3002<\/strong>\u30bb\u30f3\u30b7\u30c6\u30a3\u30d6\u306a\u7d30\u80de\u306f\u3001\u30c8\u30e9\u30f3\u30b9\u30d5\u30a7\u30af\u30b7\u30e7\u30f3\u8a66\u85ac\u306b\u66dd\u9732\u5f8c\u6570\u6642\u9593\u3067\u6b7b\u6ec5\u3057\u59cb\u3081\u308b\u3053\u3068\u3082\u3042\u308a\u307e\u3059\u3002\u30c8\u30e9\u30f3\u30b9\u30d5\u30a7\u30af\u30b7\u30e7\u30f3\u306b\u3088\u3063\u3066\u3054\u4f7f\u7528\u306e\u7d30\u80de\u306b\u904e\u5ea6\u306e\u7d30\u80de\u6b7b\u304c\u751f\u3058\u305f\u5834\u5408\u306f\u3001\u30c8\u30e9\u30f3\u30b9\u30d5\u30a7\u30af\u30b7\u30e7\u30f3\u6eb6\u6db2\u3092\u9664\u53bb\u3057\u30018\uff5e24\u6642\u9593\u5f8c\u306b\u65b0\u3057\u3044\u5897\u6b96\u57f9\u5730\u3092\u88dc\u5145\u3057\u307e\u3059\u3002<\/p>\n<h3>\u30c8\u30e9\u30f3\u30b9\u30d5\u30a7\u30af\u30b7\u30e7\u30f3\u4e2d\u306e\u8840\u6e05\u306e\u5b58\u5728<\/h3>\n<p><strong>\u30c8\u30e9\u30f3\u30b9\u30d5\u30a7\u30af\u30b7\u30e7\u30f3\u8a66\u85ac\u3068siRNA\u3068\u306e\u8907\u5408\u4f53\u5f62\u6210\u306f\u3001\u8840\u6e05\u6210\u5206\u304c\u53cd\u5fdc\u3092\u59a8\u3052\u306a\u3044\u3088\u3046\u306b\u8840\u6e05\u3092\u6e1b\u91cf\u307e\u305f\u306f\u542b\u307e\u306a\u3044\u57f9\u5730\u3067\u884c\u3046\u5fc5\u8981\u304c\u3042\u308a\u307e\u3059\u3002<\/strong>\u3057\u304b\u3057\u3001\u3044\u3063\u305f\u3093\u8907\u5408\u4f53\u304c\u5f62\u6210\u3055\u308c\u308b\u3068\u3001\u4e00\u90e8\u306e\u30c8\u30e9\u30f3\u30b9\u30d5\u30a7\u30af\u30b7\u30e7\u30f3\u8a66\u85ac\u3067\u306f\u3001\u8840\u6e05\u3092\u542b\u3080\u901a\u5e38\u306e\u5897\u6b96\u57f9\u5730\u306b\u304a\u3044\u3066\u30c8\u30e9\u30f3\u30b9\u30d5\u30a7\u30af\u30b7\u30e7\u30f3\u3092\u884c\u3046\u3053\u3068\u304c\u3067\u304d\u307e\u3059\uff08\u88fd\u9020\u5143\u306e\u30a4\u30f3\u30b9\u30c8\u30e9\u30af\u30b7\u30e7\u30f3\u306b\u5f93\u3063\u3066\u304f\u3060\u3055\u3044\uff09\u3002\u30c8\u30e9\u30f3\u30b9\u30d5\u30a7\u30af\u30b7\u30e7\u30f3\u5f8c\u306e\u57f9\u990a\u57f9\u5730\u306e\u6dfb\u52a0\u3084\u4ea4\u63db\u306f\u901a\u5e38\u5fc5\u8981\u3068\u3055\u308c\u307e\u305b\u3093\u304c\u3001\u8840\u6e05\u304c\u9069\u5408\u3059\u308b\u8a66\u85ac\u3092\u4f7f\u7528\u3057\u3066\u3044\u308b\u5834\u5408\u3067\u3082\u3001\u57f9\u5730\u4ea4\u63db\u304c\u6709\u76ca\u3067\u3042\u308b\u5834\u5408\u304c\u3042\u308a\u307e\u3059\u3002\u7279\u6b8a\u306a\u8a66\u85ac\u3092\u4f7f\u7528\u3059\u308b\u524d\u306b\u306f\u8840\u6e05\u3068\u306e\u9069\u5408\u6027\u306b\u3064\u3044\u3066\u5fc5\u305a\u78ba\u8a8d\u3059\u308b\u3088\u3046\u306b\u3057\u3066\u304f\u3060\u3055\u3044\u3002\u4e00\u90e8\u306e\u30c8\u30e9\u30f3\u30b9\u30d5\u30a7\u30af\u30b7\u30e7\u30f3\u8a66\u85ac\u3067\u306f\u3001\u30c8\u30e9\u30f3\u30b9\u30d5\u30a7\u30af\u30b7\u30e7\u30f3\u4e2d\u306b\u8840\u6e05\u4e0d\u542b\u57f9\u5730\u304c\u5fc5\u8981\u3068\u3055\u308c\u3001\u6700\u521d\u306e\u30c8\u30e9\u30f3\u30b9\u30d5\u30a7\u30af\u30b7\u30e7\u30f3\u8907\u5408\u4f53\u3068\u306e\u30a4\u30f3\u30ad\u30e5\u30d9\u30fc\u30b7\u30e7\u30f3\u5f8c\u306b\u5b8c\u5168\u5897\u6b96\u57f9\u5730\u306b\u4ea4\u63db\u3059\u308b\u5fc5\u8981\u304c\u3042\u308a\u307e\u3059\u3002<\/p>\n<h3>siRNA\u5b9f\u9a13\u3092\u6210\u529f\u3055\u305b\u308b\u305f\u3081\u306e\u30b3\u30c4<\/h3>\n<ol>\n<li><strong>1\u907a\u4f1d\u5b50\u306b\u3064\u304d2\uff5e4\u7a2e\u985e\u306esiRNA\u914d\u5217\u3092\u30c7\u30b6\u30a4\u30f3\u304a\u3088\u3073\u30c6\u30b9\u30c8\u3059\u308b<\/strong>\u3000\u3054\u81ea\u5206\u3067siRNA\u3092\u30c7\u30b6\u30a4\u30f3\u3059\u308b\u5fc5\u8981\u306f\u3042\u308a\u307e\u305b\u3093\u3002<a href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/life-science\/rnai.html?CID=bid_clb_tfx_r04_jp_cp0000_pjt0000_bid00000_0so_blg_op_awa_oc_s00_cc11_Social_LAB\" target=\"_blank\" rel=\"noopener noreferrer\">\u3053\u3061\u3089\u306e\u30a6\u30a7\u30d6\u30b5\u30a4\u30c8<\/a>\u306b\u30a2\u30af\u30bb\u30b9\u3057\u3066\u3001\u6700\u9ad8\u30af\u30e9\u30b9\u306e\u30c7\u30b6\u30a4\u30f3\u30a2\u30eb\u30b4\u30ea\u30ba\u30e0\u3092\u4f7f\u7528\u3057\u3066\u3001siRNA\u3092\u30c7\u30b6\u30a4\u30f3\u3057\u3066\u304f\u3060\u3055\u3044\u3002<\/li>\n<li><strong>RNase\u6c5a\u67d3\u3092\u56de\u907f\u3059\u308b!<\/strong>\u3000\u5fae\u91cf\u306e\u30ea\u30dc\u30cc\u30af\u30ec\u30a2\u30fc\u30bc\u3067\u3042\u3063\u3066\u3082\u3001siRNA\u5b9f\u9a13\u3092\u59a8\u3052\u308b\u53ef\u80fd\u6027\u304c\u3042\u308a\u307e\u3059\u3002RNase\u306f\u3001\u7814\u7a76\u5ba4\u306e\u74b0\u5883\u4e2d- \u808c\u3001\u7a7a\u6c17\u3001\u7d20\u624b\u3067\u89e6\u3063\u305f\u3082\u306e\u3001\u7a7a\u6c17\u4e2d\u306b\u958b\u3051\u305f\u307e\u307e\u306b\u3057\u3066\u7f6e\u3044\u305f\u3082\u306e\u5168\u3066\u306b\u5b58\u5728\u3057\u3066\u3044\u308b\u305f\u3081\u3001RNase\u306e\u6c5a\u67d3\u306e\u9632\u6b62\u304a\u3088\u3073\u9664\u53bb\u306b\u5bfe\u51e6\u3059\u308b\u3053\u3068\u304c\u91cd\u8981\u3067\u3059\u3002\u5f0a\u793e\u3067\u306f\u3001RNase\u3092\u691c\u51fa\u304a\u3088\u3073\u9664\u53bb\u3059\u308b\u305f\u3081\u306e\u5b8c\u5168\u306a\u88fd\u54c1\u30e9\u30a4\u30f3\u30ca\u30c3\u30d7\u3092\u63d0\u4f9b\u3057\u3066\u3044\u307e\u3059\u3002<\/li>\n<li><strong>\u7e70\u308a\u8fd4\u3057\u826f\u597d\u306a\u52b9\u7387\u3067\u30c8\u30e9\u30f3\u30b9\u30d5\u30a7\u30af\u30b7\u30e7\u30f3\u3059\u308b\u305f\u3081\u306b\u5065\u5168\u306a\u7d30\u80de\u57f9\u990a\u304a\u3088\u3073\u53b3\u683c\u306a\u30d7\u30ed\u30c8\u30b3\u30fc\u30eb\u3092\u7dad\u6301\u3059\u308b<\/strong>\u3000\u901a\u5e38\u3001\u5065\u5168\u306a\u7d30\u80de\u306b\u306f\u5065\u5168\u6027\u304c\u4f4e\u3044\u7d30\u80de\u3088\u308a\u3082\u9ad8\u3044\u52b9\u7387\u3067\u30c8\u30e9\u30f3\u30b9\u30d5\u30a7\u30af\u30b7\u30e7\u30f3\u3055\u308c\u307e\u3059\u3002\u5c11\u306a\u3044\u7d99\u4ee3\u6570\u3067\u30eb\u30fc\u30c1\u30f3\u306b\u7d30\u80de\u3092\u7d99\u4ee3\u3059\u308b\u3053\u3068\u306b\u3088\u308a\u30011\u3064\u306e\u5b9f\u9a13\u304b\u3089\u6b21\u306e\u5b9f\u9a13\u307e\u3067\u306e\u9023\u7d9a\u7d30\u80de\u7cfb\u306e\u4e0d\u5b89\u5b9a\u6027\u3092\u6700\u5c0f\u9650\u306b\u6291\u3048\u308b\u3053\u3068\u304c\u3067\u304d\u307e\u3059\u3002\u30c8\u30e9\u30f3\u30b9\u30d5\u30a7\u30af\u30b7\u30e7\u30f3\u52b9\u7387\u306f\u7d4c\u6642\u7684\u306b\u4f4e\u4e0b\u3059\u308b\u305f\u3081\u3001\u5b9f\u9a13\u3092\u6700\u9069\u5316\u3059\u308b\u5834\u5408\u306f50\u7d99\u4ee3\u4ee5\u5185\u306e\u7d30\u80de\u306b\u30c8\u30e9\u30f3\u30b9\u30d5\u30a7\u30af\u30b7\u30e7\u30f3\u3059\u308b\u3053\u3068\u3092\u63a8\u5968\u3057\u307e\u3059\u3002<\/li>\n<li><strong>\u6297\u751f\u7269\u8cea\u306e\u4f7f\u7528\u3092\u56de\u907f\u3059\u308b<\/strong>\u3000\u30d7\u30ec\u30fc\u30c6\u30a3\u30f3\u30b0\u4e2d\u304a\u3088\u3073\u30c8\u30e9\u30f3\u30b9\u30d5\u30a7\u30af\u30b7\u30e7\u30f3\u5f8c72\u6642\u9593\u307e\u3067\u306f\u6297\u751f\u7269\u8cea\u306e\u4f7f\u7528\u3092\u56de\u907f\u3057\u307e\u3059\u3002\u900f\u904e\u6027\u7d30\u80de\u3067\u306f\u3001\u6297\u751f\u7269\u8cea\u304c\u6bd2\u6027\u30ec\u30d9\u30eb\u307e\u3067\u84c4\u7a4d\u3059\u308b\u3053\u3068\u304c\u793a\u3055\u308c\u3066\u3044\u307e\u3059\u3002\u307e\u305f\u3001\u4e00\u90e8\u306e\u7d30\u80de\u3068\u30c8\u30e9\u30f3\u30b9\u30d5\u30a7\u30af\u30b7\u30e7\u30f3\u8a66\u85ac\u306f\u3001\u6700\u9069\u306asiRNA\u5c0e\u5165\u306e\u305f\u3081\u306b\u7121\u8840\u6e05\u6761\u4ef6\u304c\u5fc5\u8981\u3068\u3057\u307e\u3059\u3002\u305d\u306e\u305f\u3081\u3001\u901a\u5e38\u306e\u5897\u6b96\u57f9\u5730\u3068\u7121\u8840\u6e05\u57f9\u5730\u306e\u4e21\u65b9\u306b\u304a\u3044\u3066\u8a66\u9a13\u7684\u306b\u30c8\u30e9\u30f3\u30b9\u30d5\u30a7\u30af\u30b7\u30e7\u30f3\u5b9f\u9a13\u3092\u884c\u3044\u3001\u305d\u308c\u305e\u308c\u306e\u30c8\u30e9\u30f3\u30b9\u30d5\u30a7\u30af\u30b7\u30e7\u30f3\u306b\u304a\u3051\u308b\u6700\u9ad8\u306e\u6761\u4ef6\u3092\u6c7a\u5b9a\u3059\u308b\u3053\u3068\u3092\u63a8\u5968\u3057\u307e\u3059\u3002<\/li>\n<li><strong>\u6700\u9069\u5316\u3055\u308c\u305f\u8a66\u85ac\u3092\u7528\u3044\u3066siRNA\u3092\u5c0e\u5165\u3059\u308b<\/strong>\u3000\u76ee\u7684\u306e\u7d30\u80de\u30bf\u30a4\u30d7\u306b\u6700\u9069\u306asiRNA\u30c8\u30e9\u30f3\u30b9\u30d5\u30a7\u30af\u30b7\u30e7\u30f3\u8a66\u85ac\u304a\u3088\u3073\u30d7\u30ed\u30c8\u30b3\u30fc\u30eb\u3092\u4f7f\u7528\u3057\u307e\u3059\u3002siRNA\u5b9f\u9a13\u3092\u6210\u529f\u3055\u305b\u308b\u305f\u3081\u306b\u306f\u3001\u30c8\u30e9\u30f3\u30b9\u30d5\u30a7\u30af\u30b7\u30e7\u30f3\u8a66\u85ac\u306e\u9078\u629e\u304c\u91cd\u8981\u3067\u3059\u3002small RNA\u306e\u5c0e\u5165\u7528\u3068\u3057\u3066\u51e6\u65b9\u3055\u308c\u3066\u3044\u308b\u30c8\u30e9\u30f3\u30b9\u30d5\u30a7\u30af\u30b7\u30e7\u30f3\u8a66\u85ac\u3092\u4f7f\u7528\u3059\u308b\u3053\u3068\u306f\u5fc5\u8981\u4e0d\u53ef\u6b20\u3067\u3059\uff08\u5e02\u8ca9\u3055\u308c\u3066\u3044\u308b\u30c8\u30e9\u30f3\u30b9\u30d5\u30a7\u30af\u30b7\u30e7\u30f3\u8a66\u85ac\u306e\u5927\u90e8\u5206\u306f\u3001\u5c0f\u3055\u3044RNA\u5206\u5b50\u7528\u3067\u306f\u306a\u304f\u5927\u304d\u3044\u30d7\u30e9\u30b9\u30df\u30c9DNA\u7528\u3068\u3057\u3066\u30c7\u30b6\u30a4\u30f3\u3055\u308c\u3066\u3044\u307e\u3059\uff09\u3002\u307e\u305f\u3001\u7279\u5b9a\u306e\u7d30\u80de\u7cfb\u306e\u30c8\u30e9\u30f3\u30b9\u30d5\u30a7\u30af\u30b7\u30e7\u30f3\u7528\u306b\u958b\u767a\u3055\u308c\u305f\u8a66\u85ac\u304c\u3042\u308b\u4e00\u65b9\u3001\u5e45\u5e83\u3044\u7279\u7570\u6027\u3092\u6301\u3064\u8a66\u85ac\u3082\u3042\u308a\u307e\u3059\u3002<\/li>\n<li><strong>\u30c8\u30e9\u30f3\u30b9\u30d5\u30a7\u30af\u30b7\u30e7\u30f3\u304a\u3088\u3073\u30a2\u30c3\u30bb\u30a4\u6761\u4ef6\u3092\u6700\u9069\u5316\u3059\u308b\u305f\u3081\u306b\u9069\u5207\u306a\u30dd\u30b8\u30c6\u30a3\u30d6\u30b3\u30f3\u30c8\u30ed\u30fc\u30eb\u3092\u4f7f\u7528\u3059\u308b<\/strong>\u3000\u30cf\u30a6\u30b9\u30ad\u30fc\u30d4\u30f3\u30b0\u907a\u4f1d\u5b50\u306f\u3001\u307b\u3068\u3093\u3069\u306e\u7d30\u80de\u30bf\u30a4\u30d7\u306b\u9069\u3057\u305f\u30dd\u30b8\u30c6\u30a3\u30d6\u30b3\u30f3\u30c8\u30ed\u30fc\u30eb\u3067\u3059\u3002\u6761\u4ef6\u3092\u6700\u9069\u5316\u3059\u308b\u305f\u3081\u306b\u306f\u3001\u9078\u629e\u3057\u305f\u30dd\u30b8\u30c6\u30a3\u30d6\u30b3\u30f3\u30c8\u30ed\u30fc\u30eb\u306b\u7279\u7570\u7684\u306asiRNA\u304a\u3088\u3073\u5b9f\u9a13\u306b\u7528\u3044\u308b\u30bf\u30fc\u30b2\u30c3\u30c8siRNA\u3092\u3044\u304f\u3064\u304b\u306e\u6fc3\u5ea6\u3067\u30bf\u30fc\u30b2\u30c3\u30c8\u7d30\u80de\u306b\u30c8\u30e9\u30f3\u30b9\u30d5\u30a7\u30af\u30b7\u30e7\u30f3\u3057\u307e\u3059\u3002\u30c8\u30e9\u30f3\u30b9\u30d5\u30a7\u30af\u30b7\u30e7\u30f348\u6642\u9593\u5f8c\u306b\u3001\u975e\u5c0e\u5165\u7d30\u80de\u3068\u6bd4\u8f03\u3057\u305f\u30b3\u30f3\u30c8\u30ed\u30fc\u30eb\u30bf\u30f3\u30d1\u30af\u8cea\u307e\u305f\u306fmRNA\u30ec\u30d9\u30eb\u306e\u4f4e\u4e0b\u3092\u6e2c\u5b9a\u3057\u307e\u3059\u3002siRNA\u6fc3\u5ea6\u304c\u9ad8\u904e\u304e\u308b\u3068\u7d30\u80de\u6bd2\u6027\u3084\u7d30\u80de\u6b7b\u306b\u3064\u306a\u304c\u308a\u307e\u3059\u3002\u6700\u5927\u306e\u5229\u4fbf\u6027\u304c\u5f97\u3089\u308c\u308b\u3088\u3046\u306b\u3001\u5f0a\u793e\u3067\u306f\u3001\u69d8\u3005\u306a\u907a\u4f1d\u5b50\u30bf\u30fc\u30b2\u30c3\u30c8\u306b\u5bfe\u3059\u308b\u30dd\u30b8\u30c6\u30a3\u30d6\u30b3\u30f3\u30c8\u30ed\u30fc\u30eb\u3092\u63d0\u4f9b\u3057\u3066\u3044\u307e\u3059\u3002<\/li>\n<li><strong>\u975e\u7279\u7570\u7684\u52b9\u679c\u3092\u533a\u5225\u3059\u308b\u305f\u3081\u306b\u3001siRNA\u30cd\u30ac\u30c6\u30a3\u30d6\u30b3\u30f3\u30c8\u30ed\u30fc\u30eb\u3092\u4f7f\u7528\u3059\u308b<\/strong>\u3000\u30cd\u30ac\u30c6\u30a3\u30d6\u30b3\u30f3\u30c8\u30ed\u30fc\u30eb\u306f\u3001\u5927\u90e8\u5206\u306e\u6d3b\u6027siRNA\u306e\u30cc\u30af\u30ec\u30aa\u30c1\u30c9\u914d\u5217\u3092\u30b9\u30af\u30e9\u30f3\u30d6\u30eb\u3059\u308b\u3053\u3068\u306b\u3088\u308a\u30c7\u30b6\u30a4\u30f3\u3059\u308b\u5fc5\u8981\u304c\u3042\u308a\u307e\u3059\u3002\u3057\u304b\u3057\u306a\u304c\u3089\u3001\u5fc5\u305a\u76f8\u540c\u6027\u691c\u7d22\u3092\u884c\u3044\u3001\u30cd\u30ac\u30c6\u30a3\u30d6\u30b3\u30f3\u30c8\u30ed\u30fc\u30eb\u914d\u5217\u304c\u7814\u7a76\u5bfe\u8c61\u306e\u751f\u7269\u7a2e\u306e\u30b2\u30ce\u30e0\u3068\u76f8\u540c\u6027\u3092\u6301\u305f\u306a\u3044\u3053\u3068\u3092\u78ba\u8a8d\u3057\u307e\u3059\u3002<\/li>\n<li><strong>\u6a19\u8b58siRNA\u3092\u4f7f\u7528\u3059\u308b\u3053\u3068\u306b\u3088\u308b\u30d7\u30ed\u30c8\u30b3\u30fc\u30eb\u306e\u6700\u9069\u5316<\/strong>\u3000\u86cd\u5149\u6a19\u8b58siRNA\u3092\u4f7f\u7528\u3059\u308b\u3053\u3068\u306b\u3088\u308a\u3001siRNA\u306e\u5b89\u5b9a\u6027\u304a\u3088\u3073\u30c8\u30e9\u30f3\u30b9\u30d5\u30a7\u30af\u30b7\u30e7\u30f3\u52b9\u7387\u3092\u89e3\u6790\u3067\u304d\u307e\u3059\u3002\u6a19\u8b58siRNA\u306f\u3001siRNA\u306e\u7d30\u80de\u5185\u5c40\u5728\u6027\u306b\u95a2\u3059\u308b\u7814\u7a76\u3084\u4e8c\u91cd\u6a19\u8b58\u5b9f\u9a13\uff08\u6a19\u8b58\u6297\u4f53\u3068\u306e\uff09\u306b\u304a\u3044\u3066\u3082\u6709\u7528\u3067\u3001\u30c8\u30e9\u30f3\u30b9\u30d5\u30a7\u30af\u30b7\u30e7\u30f3\u306e\u9593\u306bsiRNA\u3092\u53d7\u3051\u53d6\u3063\u305f\u7d30\u80de\u3092\u53ef\u8996\u5316\u3057\u3001\u30c8\u30e9\u30f3\u30b9\u30d5\u30a7\u30af\u30b7\u30e7\u30f3\u3068\u6a19\u7684\u30bf\u30f3\u30d1\u30af\u8cea\u306e\u30c0\u30a6\u30f3\u30ec\u30ae\u30e5\u30ec\u30fc\u30b7\u30e7\u30f3\u3092\u95a2\u9023\u4ed8\u3051\u3067\u304d\u307e\u3059\u3002<\/li>\n<\/ol>\n<h2>siRNA\u30c8\u30e9\u30f3\u30b9\u30d5\u30a7\u30af\u30b7\u30e7\u30f3\u306e\u6700\u9069\u5316<\/h2>\n<h3>siRNA\u30c8\u30e9\u30f3\u30b9\u30d5\u30a7\u30af\u30b7\u30e7\u30f3\u52b9\u7387\u306b\u5f71\u97ff\u3059\u308b\u8981\u7d20<\/h3>\n<p><strong>\u7d30\u80de\u6bd2\u6027\u3092\u6700\u5c0f\u9650\u306b\u6291\u3048\u306a\u304c\u3089\u6700\u9ad8\u306e\u30c8\u30e9\u30f3\u30b9\u30d5\u30a7\u30af\u30b7\u30e7\u30f3\u52b9\u7387\u3092\u5f97\u308b\u3053\u3068\u306f\u3001\u907a\u4f1d\u5b50\u30b5\u30a4\u30ec\u30f3\u30b7\u30f3\u30b0\u3092\u6700\u9069\u5316\u3059\u308b\u306e\u306b\u5fc5\u8981\u4e0d\u53ef\u6b20\u3067\u3059\u3002<\/strong>siRNA\u8a98\u5c0e\u6027\u30ce\u30c3\u30af\u30c0\u30a6\u30f3\u3068\u7d30\u80de\u751f\u5b58\u7387\u306e\u30d0\u30e9\u30f3\u30b7\u30f3\u30b0\u306b\u4f3c\u305f\u3001siRNA\u5c0e\u5165\u3068\u4e0b\u6d41\u306e\u8868\u73fe\u578b\u30a2\u30c3\u30bb\u30a4\u6761\u4ef6\u306e\u9593\u306b\u3082\u30d0\u30e9\u30f3\u30b7\u30f3\u30b0\u304c\u5b58\u5728\u3057\u307e\u3059\u3002siRNA\u30b9\u30af\u30ea\u30fc\u30cb\u30f3\u30b0\u30d1\u30b9\u306b\u304a\u3044\u3066\u7528\u3044\u3089\u308c\u308b\u69d8\u3005\u306a\u30c0\u30a6\u30f3\u30b9\u30c8\u30ea\u30fc\u30e0\u30a2\u30c3\u30bb\u30a4\u3054\u3068\u306b\u3001siRNA\u306e\u5c0e\u5165\u6761\u4ef6\u3092\u518d\u6700\u9069\u5316\u3059\u308b\u3053\u3068\u304c\u5fc5\u8981\u3068\u8003\u3048\u3089\u308c\u307e\u3059\u3002\u4e0b\u8a18\u306e\u8981\u7d20\uff08\u91cd\u8981\u6027\u306e\u9ad8\u3044\u9806\uff09\u3092\u78ba\u8a8d\u3059\u308b\u3053\u3068\u306b\u3088\u308a\u3001\u5404\u7d30\u80de\u30bf\u30a4\u30d7\u3067\u306e\u6700\u9ad8\u306e\u30c8\u30e9\u30f3\u30b9\u30d5\u30a7\u30af\u30b7\u30e7\u30f3\u52b9\u7387\u304c\u9054\u6210\u3055\u308c\u307e\u3059\u3002<\/p>\n<ol>\n<li>\u30c8\u30e9\u30f3\u30b9\u30d5\u30a7\u30af\u30b7\u30e7\u30f3\u8a66\u85ac\u306e\u9078\u629e<\/li>\n<li>\u30c8\u30e9\u30f3\u30b9\u30d5\u30a7\u30af\u30b7\u30e7\u30f3\u8a66\u85ac\u306e\u91cf<\/li>\n<li>siRNA\u306e\u91cf<\/li>\n<li>\u30c8\u30e9\u30f3\u30b9\u30d5\u30a7\u30af\u30b7\u30e7\u30f3\u6642\u306e\u7d30\u80de\u5bc6\u5ea6<\/li>\n<li>\u7d30\u80de\u306e\u30c8\u30e9\u30f3\u30b9\u30d5\u30a7\u30af\u30b7\u30e7\u30f3\u8a66\u85ac\/siRNA\u8907\u5408\u4f53\u3078\u306e\u66dd\u9732\u6642\u9593<\/li>\n<li>\u30c8\u30e9\u30f3\u30b9\u30d5\u30a7\u30af\u30b7\u30e7\u30f3\u6cd5\uff1a \u7d30\u80de\u3092\u30d7\u30ec\u30fc\u30c6\u30a3\u30f3\u30b0\u3057\u3066\u304b\u3089\u30c8\u30e9\u30f3\u30b9\u30d5\u30a7\u30af\u30b7\u30e7\u30f3\u3059\u308b\u5f93\u6765\u306e\u65b9\u6cd5\u307e\u305f\u306f\u30c8\u30e9\u30f3\u30b9\u30d5\u30a7\u30af\u30b7\u30e7\u30f3\u8a66\u85ac\u3092\u63a5\u7740\u3055\u305b\u305f\u30d7\u30ec\u30fc\u30c8\u306b\u304a\u3044\u3066\u7d30\u80de\u306b\u30c8\u30e9\u30f3\u30b9\u30d5\u30a7\u30af\u30b7\u30e7\u30f3\u3055\u305b\u308b\u30ea\u30d0\u30fc\u30b9\u30c8\u30e9\u30f3\u30b9\u30d5\u30a7\u30af\u30b7\u30e7\u30f3\u6cd5<\/li>\n<li>\u8840\u6e05\u306e\u6709\u7121: \u6700\u9ad8\u306e\u907a\u4f1d\u5b50\u30b5\u30a4\u30ec\u30f3\u30b7\u30f3\u30b0\u6761\u4ef6\u304c\u6c7a\u5b9a\u3057\u305f\u3089\u3001\u7279\u5b9a\u306e\u7d30\u80de\u30bf\u30a4\u30d7\u3092\u4f7f\u7528\u3059\u308b\u5b9f\u9a13\u9593\u3067\u6761\u4ef6\u3092\u4e00\u5b9a\u306b\u4fdd\u3061\u307e\u3059\u3002<\/li>\n<\/ol>\n<h2>\u3010\u7121\u6599\u30c0\u30a6\u30f3\u30ed\u30fc\u30c9\u3011Gibco\u7d30\u80de\u57f9\u990a\u57fa\u790e\u30cf\u30f3\u30c9\u30d6\u30c3\u30af<\/h2>\n<p>\u7d30\u80de\u57f9\u990a\u306b\u95a2\u3059\u308b\u57fa\u790e\u60c5\u5831\u3092\u89e3\u8aac\u3057\u305f\u30cf\u30f3\u30c9\u30d6\u30c3\u30af\u3092\u3054\u7528\u610f\u3057\u3066\u3044\u307e\u3059\uff08\u65e5\u672c\u8a9e\u7248\u3001\u7d04100\u30da\u30fc\u30b8\uff09\u3002PDF\u30d5\u30a1\u30a4\u30eb\u306e\u30c0\u30a6\u30f3\u30ed\u30fc\u30c9\u3092\u3054\u5e0c\u671b\u306e\u65b9\u306f\u3001\u4e0b\u8a18\u30dc\u30bf\u30f3\u3088\u308a\u304a\u7533\u3057\u8fbc\u307f\u304f\u3060\u3055\u3044\u3002<br \/>\n<a class=\"btn btn-red\" href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/global\/forms\/gibco-cell-culture-basics-handbook-form.html?CID=bid_clb_tfx_r04_jp_cp0000_pjt0000_bid00000_0so_blg_op_awa_oc_s00_cc11_Social_LAB\" target=\"_blank\" rel=\"noopener\">\u30c0\u30a6\u30f3\u30ed\u30fc\u30c9<\/a><\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>\u7814\u7a76\u7528\u306b\u306e\u307f\u4f7f\u7528\u3067\u304d\u307e\u3059\u3002\u8a3a\u65ad\u76ee\u7684\u304a\u3088\u3073\u305d\u306e\u624b\u7d9a\u304d\u4e0a\u3067\u306e\u4f7f\u7528\u306f\u3067\u304d\u307e\u305b\u3093\u3002<\/p>\n","protected":false},"excerpt":{"rendered":"<p>RNA\u306e\u30c8\u30e9\u30f3\u30b9\u30d5\u30a7\u30af\u30b7\u30e7\u30f3\u306f\u3001RNA\u3092\u7d30\u80de\u306b\u5c0e\u5165\u3059\u308b\u305f\u3081\u306e\u53e4\u5178\u7684\u306a\u30c8\u30e9\u30f3\u30b9\u30d5\u30a7\u30af\u30b7\u30e7\u30f3\u6280\u8853\u304b\u3089\u6d3e\u751f\u3057\u3066\u3044\u307e\u3059\u3002mRNA\u304c\u7d30\u80de\u306b\u5c0e\u5165\u3055\u308c\u308b\u3068\u3001\u30b3\u30fc\u30c9\u3055\u308c\u3066\u3044\u308b\u30bf\u30f3\u30d1\u30af\u8cea\u304c\u767a\u73fe\u3055\u308c\u3001\u907a\u4f1d\u5b50\u306e\u6a5f\u80fd\u304a\u3088\u3073\u8abf\u7bc0\u306b\u95a2\u3059\u308b\u7814\u7a76\u304c\u53ef\u80fd\u3068\u306a\u308a\u307e\u3059\u3002siRNA\u306f\u3001\u907a\u4f1d\u5b50\u30ce\u30c3\u30af\u30c0\u30a6\u30f3\u306e\u52b9\u679c\u306b\u3064\u3044\u3066\u8abf\u3079\u308b\u305f\u3081\u306eRNAi\u7814\u7a76\u306b\u4f7f\u7528\u3055\u308c\u307e\u3059\u3002\u4eca\u56de\u306f\u3001RNA\u3092\u7528\u3044\u305f\u30c8\u30e9\u30f3\u30b9\u30d5\u30a7\u30af\u30b7\u30e7\u30f3\u306b\u3064\u3044\u3066\u306e\u30ac\u30a4\u30c9\u30e9\u30a4\u30f3\u3068\u30d1\u30e9\u30e1\u30fc\u30bf\u306e\u6700\u9069\u5316\u65b9\u6cd5\u306b\u3064\u3044\u3066\u3054\u7d39\u4ecb\u3057\u307e\u3059\u3002<\/p>\n","protected":false},"author":988,"featured_media":2936,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_monsterinsights_skip_tracking":false,"_genesis_hide_title":false,"_genesis_hide_breadcrumbs":false,"_genesis_hide_singular_image":false,"_genesis_hide_footer_widgets":false,"_genesis_custom_body_class":"","_genesis_custom_post_class":"","_genesis_layout":"","_jetpack_newsletter_access":"","_jetpack_dont_email_post_to_subs":false,"_jetpack_newsletter_tier_id":0,"_jetpack_memberships_contains_paywalled_content":false,"_jetpack_feature_clip_id":0,"_jetpack_memberships_contains_paid_content":false,"footnotes":"","jetpack_post_was_ever_published":false},"categories":[159],"tags":[67],"division":[],"class_list":{"0":"post-571","1":"post","2":"type-post","3":"status-publish","4":"format-standard","5":"has-post-thumbnail","7":"category-cell","8":"tag-transfection","9":"entry"},"_selected_authors":"","_selected_reviewers":"","acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v27.8 (Yoast SEO v27.8) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>RNA\u30c8\u30e9\u30f3\u30b9\u30d5\u30a7\u30af\u30b7\u30e7\u30f3\u306e\u305f\u3081\u306e\u30ac\u30a4\u30c9\u30e9\u30a4\u30f3\u3068\u6700\u9069\u5316\u65b9\u6cd5 - Learning at the Bench<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/guidelines-and-optimizing-for-rna-transfection\/\" \/>\n<meta property=\"og:locale\" content=\"ja_JP\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"RNA\u30c8\u30e9\u30f3\u30b9\u30d5\u30a7\u30af\u30b7\u30e7\u30f3\u306e\u305f\u3081\u306e\u30ac\u30a4\u30c9\u30e9\u30a4\u30f3\u3068\u6700\u9069\u5316\u65b9\u6cd5\" \/>\n<meta property=\"og:description\" content=\"RNA\u306e\u30c8\u30e9\u30f3\u30b9\u30d5\u30a7\u30af\u30b7\u30e7\u30f3\u306f\u3001RNA\u3092\u7d30\u80de\u306b\u5c0e\u5165\u3059\u308b\u305f\u3081\u306e\u53e4\u5178\u7684\u306a\u30c8\u30e9\u30f3\u30b9\u30d5\u30a7\u30af\u30b7\u30e7\u30f3\u6280\u8853\u304b\u3089\u6d3e\u751f\u3057\u3066\u3044\u307e\u3059\u3002mRNA\u304c\u7d30\u80de\u306b\u5c0e\u5165\u3055\u308c\u308b\u3068\u3001\u30b3\u30fc\u30c9\u3055\u308c\u3066\u3044\u308b\u30bf\u30f3\u30d1\u30af\u8cea\u304c\u767a\u73fe\u3055\u308c\u3001\u907a\u4f1d\u5b50\u306e\u6a5f\u80fd\u304a\u3088\u3073\u8abf\u7bc0\u306b\u95a2\u3059\u308b\u7814\u7a76\u304c\u53ef\u80fd\u3068\u306a\u308a\u307e\u3059\u3002siRNA\u306f\u3001\u907a\u4f1d\u5b50\u30ce\u30c3\u30af\u30c0\u30a6\u30f3\u306e\u52b9\u679c\u306b\u3064\u3044\u3066\u8abf\u3079\u308b\u305f\u3081\u306eRNAi\u7814\u7a76\u306b\u4f7f\u7528\u3055\u308c\u307e\u3059\u3002\u4eca\u56de\u306f\u3001RNA\u3092\u7528\u3044\u305f\u30c8\u30e9\u30f3\u30b9\u30d5\u30a7\u30af\u30b7\u30e7\u30f3\u306b\u3064\u3044\u3066\u306e\u30ac\u30a4\u30c9\u30e9\u30a4\u30f3\u3068\u30d1\u30e9\u30e1\u30fc\u30bf\u306e\u6700\u9069\u5316\u65b9\u6cd5\u306b\u3064\u3044\u3066\u3054\u7d39\u4ecb\u3057\u307e\u3059\u3002\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/guidelines-and-optimizing-for-rna-transfection\/\" \/>\n<meta property=\"og:site_name\" content=\"Learning at the Bench\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/ThermoFisherJapan\" \/>\n<meta property=\"article:published_time\" content=\"2017-02-16T00:00:00+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2025-02-10T03:16:33+00:00\" \/>\n<meta property=\"og:image\" content=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/guidelines-and-optimizing-for-rna-transfection-title.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"1200\" \/>\n\t<meta property=\"og:image:height\" content=\"631\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"LATB Staff\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:creator\" content=\"@ThermoFisherJP\" \/>\n<meta name=\"twitter:site\" content=\"@ThermoFisherJP\" \/>\n<meta name=\"twitter:label1\" content=\"\u57f7\u7b46\u8005\" \/>\n\t<meta name=\"twitter:data1\" content=\"LATB Staff\" \/>\n\t<meta name=\"twitter:label2\" content=\"\u63a8\u5b9a\u8aad\u307f\u53d6\u308a\u6642\u9593\" \/>\n\t<meta name=\"twitter:data2\" content=\"22\u5206\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/guidelines-and-optimizing-for-rna-transfection\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/guidelines-and-optimizing-for-rna-transfection\\\/\"},\"author\":{\"name\":\"LATB Staff\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#\\\/schema\\\/person\\\/00a095a01d54afcdf9457465feb04f7d\"},\"headline\":\"RNA\u30c8\u30e9\u30f3\u30b9\u30d5\u30a7\u30af\u30b7\u30e7\u30f3\u306e\u305f\u3081\u306e\u30ac\u30a4\u30c9\u30e9\u30a4\u30f3\u3068\u6700\u9069\u5316\u65b9\u6cd5\",\"datePublished\":\"2017-02-16T00:00:00+00:00\",\"dateModified\":\"2025-02-10T03:16:33+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/guidelines-and-optimizing-for-rna-transfection\\\/\"},\"wordCount\":222,\"commentCount\":0,\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/guidelines-and-optimizing-for-rna-transfection\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2019\\\/07\\\/guidelines-and-optimizing-for-rna-transfection-title.jpg\",\"keywords\":[\"\u30c8\u30e9\u30f3\u30b9\u30d5\u30a7\u30af\u30b7\u30e7\u30f3\"],\"articleSection\":[\"\u7d30\u80de\u57f9\u990a\u30fb\u30a4\u30e1\u30fc\u30b8\u30f3\u30b0\"],\"inLanguage\":\"ja\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/guidelines-and-optimizing-for-rna-transfection\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/guidelines-and-optimizing-for-rna-transfection\\\/\",\"url\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/guidelines-and-optimizing-for-rna-transfection\\\/\",\"name\":\"RNA\u30c8\u30e9\u30f3\u30b9\u30d5\u30a7\u30af\u30b7\u30e7\u30f3\u306e\u305f\u3081\u306e\u30ac\u30a4\u30c9\u30e9\u30a4\u30f3\u3068\u6700\u9069\u5316\u65b9\u6cd5 - Learning at the Bench\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/guidelines-and-optimizing-for-rna-transfection\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/guidelines-and-optimizing-for-rna-transfection\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2019\\\/07\\\/guidelines-and-optimizing-for-rna-transfection-title.jpg\",\"datePublished\":\"2017-02-16T00:00:00+00:00\",\"dateModified\":\"2025-02-10T03:16:33+00:00\",\"author\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#\\\/schema\\\/person\\\/00a095a01d54afcdf9457465feb04f7d\"},\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/guidelines-and-optimizing-for-rna-transfection\\\/#breadcrumb\"},\"inLanguage\":\"ja\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/guidelines-and-optimizing-for-rna-transfection\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"ja\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/guidelines-and-optimizing-for-rna-transfection\\\/#primaryimage\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2019\\\/07\\\/guidelines-and-optimizing-for-rna-transfection-title.jpg\",\"contentUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2019\\\/07\\\/guidelines-and-optimizing-for-rna-transfection-title.jpg\",\"width\":1200,\"height\":631,\"caption\":\"guidelines-and-optimizing-for-rna-transfection-title\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/guidelines-and-optimizing-for-rna-transfection\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"RNA\u30c8\u30e9\u30f3\u30b9\u30d5\u30a7\u30af\u30b7\u30e7\u30f3\u306e\u305f\u3081\u306e\u30ac\u30a4\u30c9\u30e9\u30a4\u30f3\u3068\u6700\u9069\u5316\u65b9\u6cd5\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#website\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/\",\"name\":\"Learning at the Bench\",\"description\":\"\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"ja\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#\\\/schema\\\/person\\\/00a095a01d54afcdf9457465feb04f7d\",\"name\":\"LATB Staff\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"ja\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/8803277856c8b753feb4217dff0f9953327452df1a615c3c88b2f9864efb2ddd?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/8803277856c8b753feb4217dff0f9953327452df1a615c3c88b2f9864efb2ddd?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/8803277856c8b753feb4217dff0f9953327452df1a615c3c88b2f9864efb2ddd?s=96&d=mm&r=g\",\"caption\":\"LATB Staff\"},\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/author\\\/latbstaff\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"RNA\u30c8\u30e9\u30f3\u30b9\u30d5\u30a7\u30af\u30b7\u30e7\u30f3\u306e\u305f\u3081\u306e\u30ac\u30a4\u30c9\u30e9\u30a4\u30f3\u3068\u6700\u9069\u5316\u65b9\u6cd5 - Learning at the Bench","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/guidelines-and-optimizing-for-rna-transfection\/","og_locale":"ja_JP","og_type":"article","og_title":"RNA\u30c8\u30e9\u30f3\u30b9\u30d5\u30a7\u30af\u30b7\u30e7\u30f3\u306e\u305f\u3081\u306e\u30ac\u30a4\u30c9\u30e9\u30a4\u30f3\u3068\u6700\u9069\u5316\u65b9\u6cd5","og_description":"RNA\u306e\u30c8\u30e9\u30f3\u30b9\u30d5\u30a7\u30af\u30b7\u30e7\u30f3\u306f\u3001RNA\u3092\u7d30\u80de\u306b\u5c0e\u5165\u3059\u308b\u305f\u3081\u306e\u53e4\u5178\u7684\u306a\u30c8\u30e9\u30f3\u30b9\u30d5\u30a7\u30af\u30b7\u30e7\u30f3\u6280\u8853\u304b\u3089\u6d3e\u751f\u3057\u3066\u3044\u307e\u3059\u3002mRNA\u304c\u7d30\u80de\u306b\u5c0e\u5165\u3055\u308c\u308b\u3068\u3001\u30b3\u30fc\u30c9\u3055\u308c\u3066\u3044\u308b\u30bf\u30f3\u30d1\u30af\u8cea\u304c\u767a\u73fe\u3055\u308c\u3001\u907a\u4f1d\u5b50\u306e\u6a5f\u80fd\u304a\u3088\u3073\u8abf\u7bc0\u306b\u95a2\u3059\u308b\u7814\u7a76\u304c\u53ef\u80fd\u3068\u306a\u308a\u307e\u3059\u3002siRNA\u306f\u3001\u907a\u4f1d\u5b50\u30ce\u30c3\u30af\u30c0\u30a6\u30f3\u306e\u52b9\u679c\u306b\u3064\u3044\u3066\u8abf\u3079\u308b\u305f\u3081\u306eRNAi\u7814\u7a76\u306b\u4f7f\u7528\u3055\u308c\u307e\u3059\u3002\u4eca\u56de\u306f\u3001RNA\u3092\u7528\u3044\u305f\u30c8\u30e9\u30f3\u30b9\u30d5\u30a7\u30af\u30b7\u30e7\u30f3\u306b\u3064\u3044\u3066\u306e\u30ac\u30a4\u30c9\u30e9\u30a4\u30f3\u3068\u30d1\u30e9\u30e1\u30fc\u30bf\u306e\u6700\u9069\u5316\u65b9\u6cd5\u306b\u3064\u3044\u3066\u3054\u7d39\u4ecb\u3057\u307e\u3059\u3002","og_url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/guidelines-and-optimizing-for-rna-transfection\/","og_site_name":"Learning at the Bench","article_publisher":"https:\/\/www.facebook.com\/ThermoFisherJapan","article_published_time":"2017-02-16T00:00:00+00:00","article_modified_time":"2025-02-10T03:16:33+00:00","og_image":[{"width":1200,"height":631,"url":"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/guidelines-and-optimizing-for-rna-transfection-title.jpg","type":"image\/jpeg"}],"author":"LATB Staff","twitter_card":"summary_large_image","twitter_creator":"@ThermoFisherJP","twitter_site":"@ThermoFisherJP","twitter_misc":{"\u57f7\u7b46\u8005":"LATB Staff","\u63a8\u5b9a\u8aad\u307f\u53d6\u308a\u6642\u9593":"22\u5206"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/guidelines-and-optimizing-for-rna-transfection\/#article","isPartOf":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/guidelines-and-optimizing-for-rna-transfection\/"},"author":{"name":"LATB Staff","@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#\/schema\/person\/00a095a01d54afcdf9457465feb04f7d"},"headline":"RNA\u30c8\u30e9\u30f3\u30b9\u30d5\u30a7\u30af\u30b7\u30e7\u30f3\u306e\u305f\u3081\u306e\u30ac\u30a4\u30c9\u30e9\u30a4\u30f3\u3068\u6700\u9069\u5316\u65b9\u6cd5","datePublished":"2017-02-16T00:00:00+00:00","dateModified":"2025-02-10T03:16:33+00:00","mainEntityOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/guidelines-and-optimizing-for-rna-transfection\/"},"wordCount":222,"commentCount":0,"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/guidelines-and-optimizing-for-rna-transfection\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/guidelines-and-optimizing-for-rna-transfection-title.jpg","keywords":["\u30c8\u30e9\u30f3\u30b9\u30d5\u30a7\u30af\u30b7\u30e7\u30f3"],"articleSection":["\u7d30\u80de\u57f9\u990a\u30fb\u30a4\u30e1\u30fc\u30b8\u30f3\u30b0"],"inLanguage":"ja","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/guidelines-and-optimizing-for-rna-transfection\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/guidelines-and-optimizing-for-rna-transfection\/","url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/guidelines-and-optimizing-for-rna-transfection\/","name":"RNA\u30c8\u30e9\u30f3\u30b9\u30d5\u30a7\u30af\u30b7\u30e7\u30f3\u306e\u305f\u3081\u306e\u30ac\u30a4\u30c9\u30e9\u30a4\u30f3\u3068\u6700\u9069\u5316\u65b9\u6cd5 - Learning at the Bench","isPartOf":{"@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/guidelines-and-optimizing-for-rna-transfection\/#primaryimage"},"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/guidelines-and-optimizing-for-rna-transfection\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/guidelines-and-optimizing-for-rna-transfection-title.jpg","datePublished":"2017-02-16T00:00:00+00:00","dateModified":"2025-02-10T03:16:33+00:00","author":{"@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#\/schema\/person\/00a095a01d54afcdf9457465feb04f7d"},"breadcrumb":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/guidelines-and-optimizing-for-rna-transfection\/#breadcrumb"},"inLanguage":"ja","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/guidelines-and-optimizing-for-rna-transfection\/"]}]},{"@type":"ImageObject","inLanguage":"ja","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/guidelines-and-optimizing-for-rna-transfection\/#primaryimage","url":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/guidelines-and-optimizing-for-rna-transfection-title.jpg","contentUrl":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/guidelines-and-optimizing-for-rna-transfection-title.jpg","width":1200,"height":631,"caption":"guidelines-and-optimizing-for-rna-transfection-title"},{"@type":"BreadcrumbList","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/guidelines-and-optimizing-for-rna-transfection\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/"},{"@type":"ListItem","position":2,"name":"RNA\u30c8\u30e9\u30f3\u30b9\u30d5\u30a7\u30af\u30b7\u30e7\u30f3\u306e\u305f\u3081\u306e\u30ac\u30a4\u30c9\u30e9\u30a4\u30f3\u3068\u6700\u9069\u5316\u65b9\u6cd5"}]},{"@type":"WebSite","@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#website","url":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/","name":"Learning at the Bench","description":"","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"ja"},{"@type":"Person","@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#\/schema\/person\/00a095a01d54afcdf9457465feb04f7d","name":"LATB Staff","image":{"@type":"ImageObject","inLanguage":"ja","@id":"https:\/\/secure.gravatar.com\/avatar\/8803277856c8b753feb4217dff0f9953327452df1a615c3c88b2f9864efb2ddd?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/8803277856c8b753feb4217dff0f9953327452df1a615c3c88b2f9864efb2ddd?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/8803277856c8b753feb4217dff0f9953327452df1a615c3c88b2f9864efb2ddd?s=96&d=mm&r=g","caption":"LATB Staff"},"url":"https:\/\/admin.acceleratingscience.com\/author\/latbstaff\/"}]}},"taxonomy_info":{"category":[{"value":159,"label":"\u7d30\u80de\u57f9\u990a\u30fb\u30a4\u30e1\u30fc\u30b8\u30f3\u30b0"}],"post_tag":[{"value":67,"label":"\u30c8\u30e9\u30f3\u30b9\u30d5\u30a7\u30af\u30b7\u30e7\u30f3"}]},"featured_image_src_large":["https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/guidelines-and-optimizing-for-rna-transfection-title-1024x538.jpg",760,399,true],"author_info":{"display_name":"LATB Staff","author_link":"https:\/\/admin.acceleratingscience.com\/author\/latbstaff\/"},"comment_info":0,"category_info":[{"term_id":159,"name":"\u7d30\u80de\u57f9\u990a\u30fb\u30a4\u30e1\u30fc\u30b8\u30f3\u30b0","slug":"cell","term_group":0,"term_taxonomy_id":159,"taxonomy":"category","description":"","parent":0,"count":103,"filter":"raw","meta":[],"cat_ID":159,"category_count":103,"category_description":"","cat_name":"\u7d30\u80de\u57f9\u990a\u30fb\u30a4\u30e1\u30fc\u30b8\u30f3\u30b0","category_nicename":"cell","category_parent":0}],"tag_info":[{"term_id":67,"name":"\u30c8\u30e9\u30f3\u30b9\u30d5\u30a7\u30af\u30b7\u30e7\u30f3","slug":"transfection","term_group":0,"term_taxonomy_id":67,"taxonomy":"post_tag","description":"","parent":0,"count":17,"filter":"raw","meta":[]}],"jetpack-related-posts":[{"id":23864,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/protein-expression-cloning-bid-ts-mbr-25070\/","url_meta":{"origin":571,"position":0},"title":"\u521d\u5fc3\u8005\u3067\u3082\u5b89\u5fc3\uff01\u7c21\u5358\u306b\u3067\u304d\u308b\u767a\u73fe\u30d9\u30af\u30bf\u30fc\u306e\u4f5c\u308a\u65b9\uff1a\u4eba\u5de5\u907a\u4f1d\u5b50\u5408\u6210\u30b5\u30fc\u30d3\u30b9\u306e\u5229\u7528\u6cd5","author":"LatB Staff","date":"2025\u5e7411\u670813\u65e5","format":false,"excerpt":"\u30bf\u30f3\u30d1\u30af\u8cea\u767a\u73fe\u5b9f\u9a13\u306b\u306f\u767a\u73fe\u30d9\u30af\u30bf\u30fc\u304c\u6b20\u304b\u305b\u307e\u305b\u3093\u304c\u3001\u4e00\u304b\u3089\u4f5c\u308b\u3068\u306a\u308b\u3068\u3001\u304b\u306a\u308a\u306e\u624b\u9593\u3068\u7d4c\u9a13\u304c\u5fc5\u8981\u3067\u3059\u2026","rel":"","context":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","block_context":{"text":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/mol-bio\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/10\/protein-expression-cloning-bid-ts-mbr-25070_eyecatch.png?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/10\/protein-expression-cloning-bid-ts-mbr-25070_eyecatch.png?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/10\/protein-expression-cloning-bid-ts-mbr-25070_eyecatch.png?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/10\/protein-expression-cloning-bid-ts-mbr-25070_eyecatch.png?resize=700%2C400&ssl=1 2x"},"classes":[]},{"id":23239,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/ngs-gene-expression-csd-ts-bfx-25060\/","url_meta":{"origin":571,"position":1},"title":"\u98df\u54c1\u958b\u767a\u306b\u304a\u3051\u308b\u83cc\u53e2\u89e3\u6790\u3068\u907a\u4f1d\u5b50\u767a\u73fe\u89e3\u6790\u306e\u6d3b\u7528","author":"LatB Staff","date":"2025\u5e7410\u67088\u65e5","format":false,"excerpt":"\u907a\u4f1d\u5b50\u95a2\u9023\u306e\u89e3\u6790\u6280\u8853\u304c\u7814\u7a76\u306e\u307f\u306a\u3089\u305a\u7523\u696d\u5206\u91ce\u3067\u6d3b\u7528\u3055\u308c\u308b\u3088\u3046\u306b\u306a\u308a\u3001\u5e74\u6708\u304c\u7d4c\u904e\u3059\u308b\u306b\u3064\u308c\u3066\u5fdc\u7528\u7bc4\u56f2\u3082\u2026","rel":"","context":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","block_context":{"text":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/mol-bio\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/09\/ngs-gene-expression-gsd-ts-tr-25060_eyecatch.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/09\/ngs-gene-expression-gsd-ts-tr-25060_eyecatch.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/09\/ngs-gene-expression-gsd-ts-tr-25060_eyecatch.jpg?resize=525%2C300&ssl=1 1.5x"},"classes":[]},{"id":24187,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/ngs-gene-expression-csd-ts-ion-25073\/","url_meta":{"origin":571,"position":2},"title":"\u3010\u3084\u3063\u3066\u307f\u305f\u3011\u5fae\u91cf\u30fb\u5206\u89e3RNA\u306b\u3088\u308b\u767a\u73fe\u89e3\u6790\u306e\u6700\u9069\u89e3\u306f\uff1fRNA-Seq\u3068Ion AmpliSeq Transcriptome\u3092\u6bd4\u3079\u3066\u307f\u305f","author":"LatB Staff","date":"2025\u5e7411\u670828\u65e5","format":false,"excerpt":"\u6b21\u4e16\u4ee3\u30b7\u30fc\u30b1\u30f3\u30b5\u3067\u306e\u767a\u73fe\u89e3\u6790\u306b\u53d6\u308a\u7d44\u3080\u969b\u3001RNA\u30b5\u30f3\u30d7\u30eb\u304c\u300c\u5c11\u306a\u3059\u304e\u308b\u300d\u300c\u5206\u89e3\u3057\u3066\u3044\u308b\u300d\u3068\u3044\u3046\u72b6\u6cc1\u306f\u2026","rel":"","context":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","block_context":{"text":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/mol-bio\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/11\/ngs-gene-expression-csd-ts-ion-25073_eyecatch-scaled.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/11\/ngs-gene-expression-csd-ts-ion-25073_eyecatch-scaled.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/11\/ngs-gene-expression-csd-ts-ion-25073_eyecatch-scaled.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/11\/ngs-gene-expression-csd-ts-ion-25073_eyecatch-scaled.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/11\/ngs-gene-expression-csd-ts-ion-25073_eyecatch-scaled.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/11\/ngs-gene-expression-csd-ts-ion-25073_eyecatch-scaled.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":20124,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/exosome-gene-therapy-ts-r-25015\/","url_meta":{"origin":571,"position":3},"title":"\u3010\u7b2c1\u56de\u3011Exosome\uff08\u30a8\u30af\u30bd\u30bd\u30fc\u30e0\uff0f\u30a8\u30ad\u30bd\u30bd\u30fc\u30e0\uff09\u3068\u306f\uff1f","author":"LatB Staff","date":"2026\u5e744\u670815\u65e5","format":false,"excerpt":"Exosome\uff08\u30a8\u30af\u30bd\u30bd\u30fc\u30e0\uff0f\u30a8\u30ad\u30bd\u30bd\u30fc\u30e0\uff09\u306e\u7814\u7a76\u304c\u6ce8\u76ee\u3092\u96c6\u3081\u3066\u3044\u307e\u3059\u3002\u8208\u5473\u306f\u3042\u3063\u3066\u3082\u3001\u3069\u306e\u3088\u3046\u306b\u7814\u2026","rel":"","context":"\u305d\u306e\u4ed6","block_context":{"text":"\u305d\u306e\u4ed6","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/else\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/03\/6fae859c8c1eacdaa39f3ae843ae1bda-scaled.png?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/03\/6fae859c8c1eacdaa39f3ae843ae1bda-scaled.png?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/03\/6fae859c8c1eacdaa39f3ae843ae1bda-scaled.png?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/03\/6fae859c8c1eacdaa39f3ae843ae1bda-scaled.png?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/03\/6fae859c8c1eacdaa39f3ae843ae1bda-scaled.png?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/03\/6fae859c8c1eacdaa39f3ae843ae1bda-scaled.png?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":25325,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/exosome-gene-expression-ts-r-25019\/","url_meta":{"origin":571,"position":4},"title":"\u3010\u7b2c5\u56de\u3011 &#8220;RNA cargo&#8221;\u306e\u7cbe\u88fd\u3068\u5b9a\u91cf\u89e3\u6790\u300d\uff5emRNA\u306e\u5b9a\u91cf\u89e3\u6790\uff5e","author":"LatB Staff","date":"2026\u5e746\u670811\u65e5","format":false,"excerpt":"\u4eca\u56de\u306f\u3001\u30a8\u30af\u30bd\u30bd\u30fc\u30e0\uff08\u30a8\u30ad\u30bd\u30bd\u30fc\u30e0\uff09\u4e2d\u306emRNA\u306e\u5b9a\u91cf\u89e3\u6790\u306b\u3064\u3044\u3066\u8aac\u660e\u3057\u307e\u3059\u3002\u7b2c3\u56de\u3067\u30a8\u30af\u30bd\u30bd\u30fc\u30e0\u304b\u2026","rel":"","context":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","block_context":{"text":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/mol-bio\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25018_eyecatch-1.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25018_eyecatch-1.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25018_eyecatch-1.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25018_eyecatch-1.jpg?resize=700%2C400&ssl=1 2x"},"classes":[]},{"id":25565,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/exosome-antibody-ts-r-25068_\/","url_meta":{"origin":571,"position":5},"title":"\u3010\u7b2c8\u56de\u3011\u30a8\u30af\u30bd\u30bd\u30fc\u30e0\u30b5\u30d6\u30bf\u30a4\u30d7\u306e\u5206\u753b\u6cd5 \uff1a \u30a6\u30a7\u30b9\u30bf\u30f3\u30d6\u30ed\u30c3\u30c8\uff0fqRT-PCR\uff0f\u30b7\u30fc\u30b1\u30f3\u30b9\u89e3\u6790\u306b\u9069\u3057\u305f\u5206\u753b\u65b9\u6cd5","author":"LatB Staff","date":"2026\u5e749\u670829\u65e5","format":false,"excerpt":"\u672c\u7a3f\u3067\u306f\u3001\u30a8\u30af\u30bd\u30bd\u30fc\u30e0\u819c\u4e0a\u306e\u7279\u5b9a\u306e\u30bf\u30f3\u30d1\u30af\u8cea\u3092\u6a19\u7684\u3068\u3057\u305f\u514d\u75ab\u5438\u7740\u6cd5\u306b\u57fa\u3065\u304f\u5206\u753b\u624b\u6cd5\u3092\u7d39\u4ecb\u3057\u307e\u3059\u3002\u30a8\u30af\u2026","rel":"","context":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","block_context":{"text":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/mol-bio\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25019_eyecatch.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25019_eyecatch.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25019_eyecatch.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25019_eyecatch.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25019_eyecatch.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25019_eyecatch.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]}],"jetpack_sharing_enabled":true,"amp_enabled":true,"jetpack_featured_media_url":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/guidelines-and-optimizing-for-rna-transfection-title.jpg","_links":{"self":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/posts\/571","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/users\/988"}],"replies":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/comments?post=571"}],"version-history":[{"count":0,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/posts\/571\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/media\/2936"}],"wp:attachment":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/media?parent=571"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/categories?post=571"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/tags?post=571"},{"taxonomy":"division","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/division?post=571"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}