{"id":574,"date":"2017-12-18T00:00:00","date_gmt":"2017-12-18T00:00:00","guid":{"rendered":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/start-microarray\/"},"modified":"2025-03-10T10:56:15","modified_gmt":"2025-03-10T01:56:15","slug":"start-microarray","status":"publish","type":"post","link":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/start-microarray\/","title":{"rendered":"\u30de\u30a4\u30af\u30ed\u30a2\u30ec\u30a4\u3068\u306f\uff1f\uff5c\u30de\u30a4\u30af\u30ed\u30a2\u30ec\u30a4\u3092\u7528\u3044\u305f\u767a\u73fe\u89e3\u6790\u306e\u539f\u7406\u3068\u89e3\u6790\u65b9\u6cd5"},"content":{"rendered":"<p>\u5f0a\u793e\u306e\u4e3b\u8981\u306a\u88fd\u54c1\u3067\u3042\u308b\u30de\u30a4\u30af\u30ed\u30a2\u30ec\u30a4\u306f\u3001\u305d\u306e\u767b\u5834\u4ee5\u6765\u69d8\u3005\u306a\u5206\u91ce\u3084\u30a2\u30d7\u30ea\u30b1\u30fc\u30b7\u30e7\u30f3\u3067\u4f7f\u308f\u308c\u3066\u304d\u3066\u3044\u307e\u3059\u3002<strong>\u4eca\u56de\u306f\u30de\u30a4\u30af\u30ed\u30a2\u30ec\u30a4\u89e3\u6790\u306e\u4e2d\u304b\u3089\u3001\u3082\u3063\u3068\u3082\u4ee3\u8868\u7684\u306a\u30a2\u30d7\u30ea\u30b1\u30fc\u30b7\u30e7\u30f3\u3067\u3042\u308b\u767a\u73fe\u89e3\u6790\u306b\u3064\u3044\u3066\u3054\u7d39\u4ecb\u3057\u307e\u3059\u3002<\/strong><\/p>\n<h2>\u30de\u30a4\u30af\u30ed\u30a2\u30ec\u30a4\u3068\u306f\uff1f<\/h2>\n<p>\u30a2\u30ec\u30a4 (Array) \u306b\u306f\u6574\u5217\u3068\u304b\u914d\u5217\u3001\u306a\u3069\u3068\u3044\u3063\u305f\u610f\u5473\u304c\u3042\u308a\u307e\u3059\u306e\u3067\u3001\u30de\u30a4\u30af\u30ed\u30a2\u30ec\u30a4 (Microarray) \u3068\u306f\u6587\u5b57\u901a\u308a\u3001\u3054\u304f\u5c0f\u3055\u306a\u7269\u8cea\u304c\u6574\u7136\u3068\u4e26\u3093\u3067\u3044\u308b\u30a4\u30e1\u30fc\u30b8\u3092\u6301\u3064\u3068\u826f\u3044\u3067\u3057\u3087\u3046\u3002<strong>\u3053\u308c\u3089\u306e\u5fae\u5c0f\u306a\u7269\u8cea\u3068\u306e\u76f8\u4e92\u4f5c\u7528\u3092\u901a\u3057\u3066\u3001\u5b9f\u9a13\u5ba4\u30ec\u30d9\u30eb\u3067\u304a\u3053\u306a\u308f\u308c\u308b\u4f5c\u696d\u3092\u30df\u30af\u30ed\u30ec\u30d9\u30eb\u3067\u5927\u91cf\u304b\u3064\u540c\u6642\u4e26\u884c\u306b\u51e6\u7406\u3067\u304d\u308b\u306e\u304c\u3001\u30de\u30a4\u30af\u30ed\u30a2\u30ec\u30a4\u306e\u7279\u5fb4<\/strong>\u3068\u8a00\u3048\u307e\u3059\u3002<\/p>\n<p>\u6574\u7136\u3068\u4e26\u3093\u3067\u3044\u308b\u5fae\u5c0f\u7269\u8cea\u306b\u306f\u69d8\u3005\u306a\u3082\u306e\u304c\u8003\u3048\u3089\u308c\u307e\u3059\u304c\u3001<strong>\u751f\u7269\u5b66\u7684\u306a\u5b9f\u9a13\u306b\u304a\u3044\u3066\u306f\u6838\u9178\u3001\u30da\u30d7\u30c1\u30c9\u3001\u6297\u4f53\u306a\u3069\u3092\u7528\u3044\u308b\u306e\u304c\u4e00\u822c\u7684<\/strong>\u3067\u3059\u3002\u7279\u306bDNA\u65ad\u7247\u3092\u4e26\u3079\u305fDNA\u30de\u30a4\u30af\u30ed\u30a2\u30ec\u30a4\u306f\u3001\u30de\u30a4\u30af\u30ed\u30a2\u30ec\u30a4\u306e\u4e2d\u3067\u3082\u6700\u3082\u983b\u7e41\u306b\u5229\u7528\u3055\u308c\u3066\u3044\u308b\u3053\u3068\u304b\u3089\u3001\u305f\u3060\u5358\u306b\u30de\u30a4\u30af\u30ed\u30a2\u30ec\u30a4\u3068\u3044\u3063\u305f\u5834\u5408\u306fDNA\u30de\u30a4\u30af\u30ed\u30a2\u30ec\u30a4\u306e\u3053\u3068\u3092\u6307\u3057\u3066\u3044\u308b\u3053\u3068\u3082\u591a\u3044\u3088\u3046\u3067\u3059\u3002\u5b9f\u969b\u3001\u3053\u306e\u30da\u30fc\u30b8\u3067\u3082DNA\u30de\u30a4\u30af\u30ed\u30a2\u30ec\u30a4\u3092\u77ed\u7e2e\u3057\u3066\u3001\u305f\u3060\u5358\u306b\u30de\u30a4\u30af\u30ed\u30a2\u30ec\u30a4\u3068\u547c\u3076\u3053\u3068\u306b\u3057\u3066\u3044\u307e\u3059\u3002<\/p>\n<p>DNA\u65ad\u7247\u306f\u30c1\u30c3\u30d7\uff08\u57fa\u76e4\uff09\u4e0a\u306b\u56fa\u5b9a\u5316\u3055\u308c\u3066\u3044\u308b\u306e\u3067\u3001<strong>\u30de\u30a4\u30af\u30ed\u30a2\u30ec\u30a4\u306e\u3053\u3068\u3092DNA\u30c1\u30c3\u30d7\u3068\u547c\u3076\u3053\u3068\u3082\u3042\u308a\u307e\u3059\u304c\u3001\u5b9f\u8cea\u7684\u306b\u4e21\u8005\u306f\u5168\u304f\u540c\u3058\u3082\u306e<\/strong>\u3067\u3059\u3002\u307e\u305f\u30de\u30a4\u30af\u30ed\u30a2\u30ec\u30a4\u306e\u3053\u3068\u3092GeneChip\uff08\u30b8\u30fc\u30f3\u30c1\u30c3\u30d7\uff09\u3068\u547c\u3076\u65b9\u3082\u3044\u3089\u3063\u3057\u3083\u3044\u307e\u3059\u304c\u3001\u5b9f\u306fGeneChip\u306f\u5f0a\u793e\u304c\u547d\u540d\u3057\u305f\u30d6\u30e9\u30f3\u30c9\u540d\u3067\u3042\u308b\u3053\u3068\u3092\u3054\u5b58\u77e5\u306e\u65b9\u306f\u610f\u5916\u3068\u5c11\u306a\u3044\u304b\u3082\u3057\u308c\u307e\u305b\u3093\u3002\u30de\u30a4\u30af\u30ed\u30a2\u30ec\u30a4\u304c\u4e00\u822c\u540d\u8a5e\u306a\u306e\u306b\u5bfe\u3057\u3066\u3001GeneChip\u3068\u3044\u3046\u306e\u306f\u5546\u54c1\u540d\uff08\u30d6\u30e9\u30f3\u30c9\u540d\uff09\u3067\u3059\u3002\u88fd\u54c1\u306e\u666e\u53ca\u306b\u3068\u3082\u306a\u3063\u3066\u88fd\u54c1\u540d\u304c\u56fa\u6709\u540d\u8a5e\u5316\u3059\u308b\u4f8b\u306f\u3044\u308d\u3044\u308d\u3068\u3042\u308a\u307e\u3059\u304c\uff08\u30b5\u30e9\u30f3\u30e9\u30c3\u30d7\u3001\u30bb\u30ed\u30c6\u30fc\u30d7\u3001\u306a\u3069\uff09\u3001\u5f0a\u793e\u306eGeneChip\u3082\u30de\u30a4\u30af\u30ed\u30a2\u30ec\u30a4\u306e\u4ee3\u540d\u8a5e\u3068\u3057\u3066\u591a\u304f\u306e\u65b9\u306b\u8a8d\u3081\u3066\u3044\u305f\u3060\u3044\u3066\u3044\u308b\u8a3c\u3068\u3044\u3048\u308b\u3067\u3057\u3087\u3046\u3002<\/p>\n<h2>\u30de\u30a4\u30af\u30ed\u30a2\u30ec\u30a4\u306e\u6b74\u53f2<\/h2>\n<p>\u5f0a\u793e\u306eGeneChip\u00ae\u30c6\u30af\u30ce\u30ed\u30b8\u30fc\u306f\u30011980\u5e74\u4ee3\u5f8c\u534a\u306bStephen P.A. Fodor\u535a\u58eb\u7387\u3044\u308b\u79d1\u5b66\u8005\u30c1\u30fc\u30e0\u306b\u3088\u3063\u3066\u767a\u660e\u3055\u308c\u307e\u3057\u305f\u3002\u3053\u308c\u306f\u5fae\u5c0f\u306a\u30ac\u30e9\u30b9\u30c1\u30c3\u30d7\u306e\u4e0a\u306bDNA\u30d7\u30ed\u30fc\u30d6\u3092\u5408\u6210\u3057\u3001\u591a\u91cf\u306e\u751f\u7269\u5b66\u7684\u30c7\u30fc\u30bf\u3092\u69cb\u7bc9\u3059\u308b\u3068\u3044\u3046\u9769\u65b0\u7684\u306a\u7406\u8ad6\u306b\u57fa\u3065\u3044\u305f\u6280\u8853\u3067\u3059\u3002\u3053\u306e\u6280\u8853\u3092\u3082\u3068\u306b\u3057\u3066\u3001\u30a2\u30d5\u30a3\u30e1\u30c8\u30ea\u30af\u30b9\uff08\u73fe\u30b5\u30fc\u30e2\u30d5\u30a3\u30c3\u30b7\u30e3\u30fc\u30b5\u30a4\u30a8\u30f3\u30c6\u30a3\u30d5\u30a3\u30c3\u30af\uff09\u306f1992\u5e74\u306e\u5275\u696d\u4ee5\u6765\u3001\u30de\u30a4\u30af\u30ed\u30a2\u30ec\u30a4\u30c6\u30af\u30ce\u30ed\u30b8\u30fc\u306e\u767a\u5c55\u3092\u5e38\u306b\u30ea\u30fc\u30c9\u3057\u3066\u304d\u307e\u3057\u305f\u3002\u73fe\u5728\u3067\u306f\u533b\u5b66\u3084\u85ac\u5b66\u3001\u751f\u7269\u5b66\u306e\u307f\u306a\u3089\u305a\u3001\u4e00\u822c\u6d88\u8cbb\u8005\u5411\u3051\u907a\u4f1d\u5b50\u691c\u67fb\u3084\u30a2\u30b0\u30ea\u30d0\u30a4\u30aa\u306a\u3069\u3001\u5e45\u5e83\u3044\u30d8\u30eb\u30b9\u30b5\u30a4\u30a8\u30f3\u30b9\u3084\u30d0\u30a4\u30aa\u30ed\u30b8\u30fc\u306e\u5206\u91ce\u3067\u6d3b\u7528\u3055\u308c\u3001\u6570\u591a\u304f\u306e\u8ad6\u6587\u306b\u5f0a\u793e\u306e\u30de\u30a4\u30af\u30ed\u30a2\u30ec\u30a4\u304c\u4f7f\u308f\u308c\u3066\u3044\u307e\u3059\u3002<\/p>\n<h2>\u30de\u30a4\u30af\u30ed\u30a2\u30ec\u30a4\u3068DNA\u30d7\u30ed\u30fc\u30d6<\/h2>\n<p>\u30de\u30a4\u30af\u30ed\u30a2\u30ec\u30a4\u3092\u62e1\u5927\u3057\u3066\u307f\u308b\u3068\u4e0b\u8a18\u306e\u56f3\u306e\u3088\u3046\u306b\u8868\u3059\u3053\u3068\u304c\u3067\u304d\u307e\u3059\u3002<\/p>\n<div id=\"attachment_1679\" style=\"width: 774px\" class=\"wp-caption aligncenter\"><a href=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/start-microarray-fig1.jpg\" rel=\"attachment wp-att-1679\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-1679\" class=\"size-full wp-image-1679\" src=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/start-microarray-fig1.jpg\" alt=\"start-microarray-fig1\" width=\"764\" height=\"418\" \/><\/a><p id=\"caption-attachment-1679\" class=\"wp-caption-text\">\u56f31 \u30de\u30a4\u30af\u30ed\u30a2\u30ec\u30a4\u306e\u62e1\u5927\u56f3<\/p><\/div>\n<p>\u30de\u30a4\u30af\u30ed\u30a2\u30ec\u30a4\u4e0a\u306b\u306f\u5404DNA\u30d7\u30ed\u30fc\u30d6\u304c\u56fa\u5b9a\u5316\u3055\u308c\u3066\u3044\u308b\u5c0f\u3055\u306a\u533a\u5207\u308a\u304c\u591a\u6570\u3042\u308a\u307e\u3059\u304c\u3001\u5f0a\u793e\u3067\u306f\u3053\u306e\u533a\u5207\u308a\u4e00\u3064\u4e00\u3064\u306e\u3053\u3068\u3092<strong>\u30bb\u30eb<\/strong>\u3068\u547c\u3093\u3067\u3044\u307e\u3059\u3002\u5404\u30bb\u30eb\u306b\u306f\u540c\u4e00\u306eDNA\u30d7\u30ed\u30fc\u30d6\u304c\u56fa\u5b9a\u5316\u3055\u308c\u3066\u304a\u308a\u3001\u305d\u308c\u305e\u308c\u306e\u30bb\u30eb\u4e0a\u306b\u3042\u308bDNA\u30d7\u30ed\u30fc\u30d6\u304c\u89e3\u6790\u3057\u305f\u3044\u907a\u4f1d\u5b50\u306b\u5bfe\u5fdc\u3057\u3066\u3044\u307e\u3059\u3002<\/p>\n<p>\u30de\u30a4\u30af\u30ed\u30a2\u30ec\u30a4\u4e0a\u306e\u30bb\u30eb\u306e\u6570\u3092<strong>\u30d5\u30a3\u30fc\u30c1\u30e3\u30fc\u30b5\u30a4\u30ba<\/strong>\u3068\u547c\u3093\u3067\u304a\u308a\u3001\u3053\u306e\u6570\u304c\u591a\u3051\u308c\u3070\u591a\u3044\u307b\u3069\u591a\u6570\u306e\u907a\u4f1d\u5b50\u3084\u30a8\u30af\u30bd\u30f3\u3092\u89e3\u6790\u3067\u304d\u307e\u3059\u3002\u5f0a\u793e\u306e\u767a\u73fe\u89e3\u6790\u30de\u30a4\u30af\u30ed\u30a2\u30ec\u30a4\u306e\u3046\u3061\u3001\u3082\u3063\u3068\u3082\u30d5\u30a3\u30fc\u30c1\u30e3\u30fc\u30b5\u30a4\u30ba\u306e\u5927\u304d\u306a\u88fd\u54c1\u306f<a href=\"http:\/\/www.thermofisher.com\/search\/results?query=Clariom%20D&amp;resultPage=1&amp;resultsPerPage=15&amp;autocomplete=&amp;CID=gsd_mic_gex_r04_jp_cp0000_pjt0000_gsd00000_0so_blg_op_awa_oc_s00_ma3_Social_LAB\" target=\"_blank\" rel=\"noopener noreferrer\">Clariom D<\/a>\u3067\u3059\u304c\u3001\u305d\u306e\u6570\u306f\u5b9f\u306b<strong>600\u4e07\u4ee5\u4e0a<\/strong>\u3068\u3001\u4ed6\u306e\u30de\u30a4\u30af\u30ed\u30a2\u30ec\u30a4\u88fd\u54c1\u306e\u8ffd\u968f\u3092\u8a31\u3057\u307e\u305b\u3093\u3002<\/p>\n<p><strong>\u30de\u30a4\u30af\u30ed\u30a2\u30ec\u30a4\u306e\u6027\u80fd\u306f\u3069\u308c\u3060\u3051\u591a\u304f\u306e\u30d7\u30ed\u30fc\u30d6\u3092\u914d\u7f6e\u3067\u304d\u308b\u304b\u3067\u5927\u304d\u304f\u7570\u306a\u3063\u3066\u304d\u307e\u3059\u3002<\/strong>\u88fd\u54c1\u3092\u9078\u3076\u969b\u306b\u306f\u662f\u975e\u3068\u3082\u30de\u30a4\u30af\u30ed\u30a2\u30ec\u30a4\u306e\u30d5\u30a3\u30fc\u30c1\u30e3\u30fc\u30b5\u30a4\u30ba\u3068\u30d7\u30ed\u30fc\u30d6\u6570\u3092\u6c17\u306b\u304b\u3051\u3066\u307f\u3066\u304f\u3060\u3055\u3044\u3002<\/p>\n<p>\u306a\u304a\u3001\u5f0a\u793e\u306e\u30de\u30a4\u30af\u30ed\u30a2\u30ec\u30a4\u306f\u534a\u5c0e\u4f53\u88fd\u9020\u3067\u7528\u3044\u3089\u308c\u3066\u3044\u308b\u6280\u8853\u3092\u5fdc\u7528\u3057\u3066\u3044\u308b\u305f\u3081\u3001\u9ad8\u5bc6\u5ea6\u306a\u30d7\u30ed\u30fc\u30d6\u306e\u914d\u7f6e\u304c\u53ef\u80fd\u3068\u306a\u3063\u3066\u3044\u307e\u3059\u3002<\/p>\n<h2>\u30de\u30a4\u30af\u30ed\u30a2\u30ec\u30a4\u306e\u88fd\u9020\u6280\u8853<\/h2>\n<p>\u5f0a\u793e\u306f\u3001\u534a\u5c0e\u4f53\u306e\u88fd\u9020\u6280\u8853\u306b\u4f7f\u308f\u308c\u3066\u3044\u308b\u30d5\u30a9\u30c8\u30ea\u30bd\u30b0\u30e9\u30d5\u30a3\u30fc\u6280\u8853\u3068\u3001\u30b3\u30f3\u30d3\u30ca\u30c8\u30ea\u30a2\u30eb\u30fb\u30b1\u30df\u30b9\u30c8\u30ea\u30fc\u3092\u878d\u5408\u3055\u305b\u308b\u3053\u3068\u306b\u3088\u308a\u3001\u8d85\u9ad8\u5bc6\u5ea6\u306a\u30de\u30a4\u30af\u30ed\u30a2\u30ec\u30a4\u88fd\u9020\u6280\u8853\u3092\u78ba\u7acb\u3057\u307e\u3057\u305f\u3002<\/p>\n<div id=\"attachment_2093\" style=\"width: 510px\" class=\"wp-caption aligncenter\"><a href=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/start-microarray-fig0-1.png\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-2093\" class=\"wp-image-2093 size-full\" src=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/start-microarray-fig0-1.png\" alt=\"\" width=\"500\" height=\"318\" \/><\/a><p id=\"caption-attachment-2093\" class=\"wp-caption-text\">\u56f32 \u30de\u30a4\u30af\u30ed\u30a2\u30ec\u30a4\u306e\u88fd\u9020\u904e\u7a0b<\/p><\/div>\n<p>\u30de\u30a4\u30af\u30ed\u30a2\u30ec\u30a4\u306f5\u30a4\u30f3\u30c1\u89d2\u306e\u30a6\u30a7\u30cf\u30fc\u3092\u7528\u3044\u3066\u88fd\u9020\u3055\u308c\u307e\u3059\u3002\u5408\u6210\u5b8c\u4e86\u5f8c\u306b\u30a6\u30a7\u30cf\u30fc\u3092\u5207\u65ad\u3057\u3066\u5f97\u3089\u308c\u305f\u500b\u3005\u306e\u30a2\u30ec\u30a4\u306f\u3001\u30ab\u30fc\u30c8\u30ea\u30c3\u30b8\u307e\u305f\u306f\u30a2\u30ec\u30a4\u30d7\u30ec\u30fc\u30c8\u3084\u30a2\u30ec\u30a4\u30b9\u30c8\u30ea\u30c3\u30d7\u306b\u7d44\u307f\u8fbc\u307e\u308c\u307e\u3059\u3002\u5f0a\u793e\u306e\u30de\u30a4\u30af\u30ed\u30a2\u30ec\u30a4\u306f\u3001\u9ad8\u5ea6\u306b\u30b3\u30f3\u30c8\u30ed\u30fc\u30eb\u3055\u308c\u305f\u88fd\u9020\u30d7\u30ed\u30bb\u30b9\u306b\u3088\u308a\u3001\u30ed\u30c3\u30c8\u3054\u3068\u306e\u30de\u30fc\u30ab\u30fc\u306e\u6b20\u843d\u304c\u306a\u304f\u3001\u5e38\u306b\u9ad8\u3044\u7cbe\u5ea6\u3068\u518d\u73fe\u6027\u304c\u78ba\u4fdd\u3055\u308c\u3066\u3044\u307e\u3059\u3002<\/p>\n<h2>GeneChip\u30d7\u30ed\u30fc\u30d6\u30a2\u30ec\u30a4\u306e\u5408\u6210\u5de5\u7a0b<\/h2>\n<p>\u5149\u5316\u5b66\u53cd\u5fdc\u3067\u53d6\u308a\u9664\u304f\u3053\u3068\u304c\u3067\u304d\u308b\u4fdd\u8b77\u57fa\u3092\u6301\u3063\u305f\u5408\u6210\u30ea\u30f3\u30ab\u30fc\u3092\u77f3\u82f1\u30ac\u30e9\u30b9\u306e\u57fa\u677f\u4e0a\u306b\u7d50\u5408\u3055\u305b\u3066\u304a\u304d\u3001\u30de\u30b9\u30af\u3068\u547c\u3070\u308c\u308b\u906e\u853d\u7269\u8cea\u3092\u901a\u3057\u3066\u7d2b\u5916\u7dda\u306e\u5149\u3092\u7167\u5c04\u3059\u308b\u3053\u3068\u306b\u3088\u308a\u3001\u7279\u5b9a\u306e\u9818\u57df\u3060\u3051\u4fdd\u8b77\u57fa\u3092\u8131\u96e2\u3055\u305b\u3001\u6c34\u9178\u57fa\u3092\u9732\u51fa\u3055\u305b\u307e\u3059\u3002\u8131\u4fdd\u8b77\u53ef\u80fd\u306a\u4fdd\u8b77\u57fa\u3067\u4fee\u98fe\u3055\u308c\u305f\u30c7\u30aa\u30ad\u30b7\u30cc\u30af\u30ec\u30aa\u30c1\u30c9\u306e\u3046\u3061\u306e\u3044\u305a\u308c\u304b1\u7a2e\u985e\u3068\u53cd\u5fdc\u3055\u305b\u308b\u3068\u3001\u524d\u306e\u30b9\u30c6\u30c3\u30d7\u3067\u5149\u304c\u7167\u5c04\u3055\u308c\u305f\u90e8\u5206\u3067\u306e\u307f\u3001\u91cd\u5408\u53cd\u5fdc\u304c\u8d77\u3053\u308a\u307e\u3059\u3002\u6b21\u306e\u30e9\u30a6\u30f3\u30c9\u306e\u8131\u4fdd\u8b77\u3068\u30ab\u30c3\u30d7\u30ea\u30f3\u30b0\u53cd\u5fdc\u3092\u884c\u3046\u305f\u3081\u306b\u3001\u5225\u306e\u30de\u30b9\u30af\u3067\u57fa\u677f\u4e0a\u306e\u7570\u306a\u308b\u9818\u57df\u3092\u7167\u5c04\u3057\u3001\u30cc\u30af\u30ec\u30aa\u30c1\u30c9\u306e\u91cd\u5408\u53cd\u5fdc\u304c\u7e70\u308a\u8fd4\u3055\u308c\u307e\u3059\u3002<\/p>\n<p>\u3053\u306e\u3088\u3046\u306b\u3001\u7570\u306a\u308b\u30de\u30b9\u30af\u3092\u9069\u7528\u3057\u305f\u4fdd\u8b77\u57fa\u306e\u8131\u4fdd\u8b77\u3068\u3001A, C, T, G\u305d\u308c\u305e\u308c\u306e\u5869\u57fa\u3092\u6301\u3063\u305f\u30cc\u30af\u30ec\u30aa\u30c1\u30c9\u30e2\u30ce\u30de\u30fc\u524d\u99c6\u4f53\u306e\u30ab\u30c3\u30d7\u30ea\u30f3\u30b0\u53cd\u5fdc\u3092\u3001\u30d7\u30ed\u30fc\u30d6\u304c\u901a\u5e3825\u5869\u57fa\u3067\u3042\u308b\u5168\u9577\u306b\u9054\u3059\u308b\u307e\u3067\u7e70\u308a\u8fd4\u3059\u3053\u3068\u3067\u3001\u30a2\u30ec\u30a4\u57fa\u677f\u4e0a\u306e\u7279\u5b9a\u306e\u9818\u57df\u306b\u3001\u4efb\u610f\u306e\u914d\u5217\u306e\u30aa\u30ea\u30b4\u30cc\u30af\u30ec\u30aa\u30c1\u30c9\u30d7\u30ed\u30fc\u30d6\u3092\u5408\u6210\u3059\u308b\u3053\u3068\u304c\u53ef\u80fd\u3068\u306a\u308a\u307e\u3059\u3002<\/p>\n<div id=\"attachment_2094\" style=\"width: 1210px\" class=\"wp-caption aligncenter\"><a href=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/start-microarray-fig0-2.jpg\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-2094\" class=\"wp-image-2094 size-full\" src=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/start-microarray-fig0-2.jpg\" alt=\"start-microarray-fig0-2\" width=\"1200\" height=\"804\" \/><\/a><p id=\"caption-attachment-2094\" class=\"wp-caption-text\">\u56f33 GeneChip\u30d7\u30ed\u30fc\u30d6\u30a2\u30ec\u30a4\u306e\u5408\u6210\u5de5\u7a0b\u30021.\u30d5\u30a9\u30c8\u30ea\u30bd\u30b0\u30e9\u30d5\u30a3\u30c3\u30af\u30de\u30b9\u30af\u3092\u5229\u7528\u3057\u3066\u3001\u6d3b\u6027\u5316\u3055\u305b\u305f\u3044\u90e8\u4f4d\u3092\u7279\u7570\u7684\u306b\u5149\u7167\u5c04\u3057\u307e\u3059\u30022.\u5149\u7167\u5c04\u3057\u305f\u9818\u57df\u304c\u6d3b\u6027\u5316\u3055\u308c\u307e\u3059\u30023.\u30cc\u30af\u30ec\u30aa\u30c1\u30c9\u3068\u30a4\u30f3\u30ad\u30e5\u30d9\u30fc\u30b7\u30e7\u30f3\u3059\u308b\u3068\u3001\u6d3b\u6027\u5316\u3055\u308c\u305f\u4f4d\u7f6e\u306b\u304a\u3044\u3066\u306e\u307f\u5316\u5b66\u7684\u306a\u30ab\u30c3\u30d7\u30ea\u30f3\u30b0\u53cd\u5fdc\u304c\u8d77\u3053\u308a\u307e\u3059\u30024.\u6b21\u306b\u3001\u65b0\u898f\u306e\u30de\u30b9\u30af\u30d1\u30bf\u30fc\u30f3\u3092\u4f7f\u7528\u3057\u307e\u3059\u30025.1\uff5e3\u3068\u540c\u69d8\u306e\u30ab\u30c3\u30d7\u30ea\u30f3\u30b0\u30b9\u30c6\u30c3\u30d7\u304c\u7e70\u308a\u8fd4\u3055\u308c\u307e\u3059\u30026.\u3053\u306e\u904e\u7a0b\u3092\u7e70\u308a\u8fd4\u3057\u3066\u76ee\u7684\u3068\u3059\u308b\u9577\u3055\u306e\u30aa\u30ea\u30b4\u30cc\u30af\u30ec\u30aa\u30c1\u30c9\u30d7\u30ed\u30fc\u30d6\u3092\u5408\u6210\u3057\u307e\u3059\u3002<\/p><\/div>\n<h2>\u30de\u30a4\u30af\u30ed\u30a2\u30ec\u30a4\u306b\u3088\u308b\u767a\u73fe\u89e3\u6790\u306e\u539f\u7406<\/h2>\n<p>\u30de\u30a4\u30af\u30ed\u30a2\u30ec\u30a4\u306b\u3088\u308b<strong>\u767a\u73fe\u89e3\u6790\u3067\u306f\u30b5\u30f3\u30d7\u30eb\u4e2d\u306eRNA\u3092\u86cd\u5149\u30e9\u30d9\u30eb\u3057\u3001\u30de\u30a4\u30af\u30ed\u30a2\u30ec\u30a4\u4e0a\u306e\u30d7\u30ed\u30fc\u30d6\u3068\u7d50\u5408\u3055\u305b\u307e\u3059\u304c\u3001\u3053\u306e\u7d50\u5408\u306e\u3053\u3068\u3092\u30cf\u30a4\u30d6\u30ea\u30c0\u30a4\u30bc\u30fc\u30b7\u30e7\u30f3\u3068\u547c\u3073\u307e\u3059\u3002<\/strong><\/p>\n<p>\u30cf\u30a4\u30d6\u30ea\u30c0\u30a4\u30bc\u30fc\u30b7\u30e7\u30f3\u306e\u7d50\u679c\u3001\u30b5\u30f3\u30d7\u30eb\u4e2d\u306b\u591a\u304f\u5b58\u5728\u3059\u308bRNA\u306f\u30d7\u30ed\u30fc\u30d6\u3068\u305f\u304f\u3055\u3093\u7d50\u5408\u3057\u3001\u305d\u306e\u90e8\u5206\u306e\u30bb\u30eb\u304c\u5f37\u304f\u5149\u308a\u307e\u3059\u3002\u9006\u306bRNA\u304c\u5c11\u306a\u3044\u5834\u5408\u306f\u30d7\u30ed\u30fc\u30d6\u3078\u306e\u7d50\u5408\u6570\u304c\u5c0f\u3055\u304f\u306a\u308b\u306e\u3067\u3001\u86cd\u5149\u5f37\u5ea6\u306f\u5f31\u304f\u306a\u308a\u307e\u3059\u3002<strong>\u767a\u73fe\u89e3\u6790\u3067\u306f\u3001\u3053\u3046\u3057\u305f\u5404\u30bb\u30eb\u3054\u3068\u306e\u86cd\u5149\u5f37\u5ea6\u306e\u5f37\u3055\u3092\u6e2c\u5b9a\u3059\u308b\u3053\u3068\u3067\u3001\u30b5\u30f3\u30d7\u30eb\u4e2d\u306e\u5404RNA\u306e\u767a\u73fe\u91cf\u3092\u89e3\u6790\u3067\u304d\u308b\u306e\u3067\u3059\u3002<\/strong>\u3053\u308c\u304c\u30de\u30a4\u30af\u30ed\u30a2\u30ec\u30a4\u306b\u3088\u308b\u767a\u73fe\u89e3\u6790\u306e\u57fa\u672c\u7684\u306a\u539f\u7406\u3067\u3059\u3002<\/p>\n<p>\u3061\u306a\u307f\u306b\u30b5\u30f3\u30d7\u30eb\u306eRNA\u3092\u30e9\u30d9\u30eb\u3059\u308b\u969b\u306b1\u7a2e\u985e\u306e\u8272\u3067\u30e9\u30d9\u30eb\u3059\u308b\u65b9\u6cd5\u30921\u8272\u6cd5\u3068\u547c\u3073\u30012\u7a2e\u985e\u306e\u8272\u3067\u30e9\u30d9\u30eb\u3059\u308b\u65b9\u6cd5\u30922\u8272\u6cd5\u3068\u547c\u3093\u3067\u3044\u307e\u3059\u3002\u5f0a\u793e\u306e\u30de\u30a4\u30af\u30ed\u30a2\u30ec\u30a4\u3067\u306f1\u7a2e\u985e\u306e\u86cd\u5149\u8272\u7d20\u306e\u86cd\u5149\u5f37\u5ea6\u3092\u6e2c\u5b9a\u3059\u308b1\u8272\u6cd5\u3092\u63a1\u7528\u3057\u3066\u3044\u307e\u3059\u3002<\/p>\n<p>\u4e0b\u306e\u56f3\u306f\u30cf\u30a4\u30d6\u30ea\u30c0\u30a4\u30bc\u30fc\u30b7\u30e7\u30f3\u5f8c\u306e\u30de\u30a4\u30af\u30ed\u30a2\u30ec\u30a4\u3092\u5c02\u7528\u306e\u88c5\u7f6e\u3067\u8aad\u307f\u53d6\u3063\u305f\u969b\u306e\u753b\u50cf\u3067\u3059\u3002\u3088\u304f\u898b\u308b\u3068\u7d30\u304b\u3044\u70b9\u304c\u7121\u6570\u306b\u6563\u3089\u3070\u3063\u3066\u3044\u308b\u306e\u304c\u5206\u304b\u308b\u304b\u3068\u601d\u3044\u307e\u3059\u304c\u3001\u3053\u306e\u70b9\u4e00\u3064\u4e00\u3064\u304c\u30de\u30a4\u30af\u30ed\u30a2\u30ec\u30a4\u306e\u5404\u30bb\u30eb\u306b\u5bfe\u5fdc\u3057\u3066\u3044\u307e\u3059\u3002<\/p>\n<div id=\"attachment_1680\" style=\"width: 657px\" class=\"wp-caption aligncenter\"><a href=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/start-microarray-fig2.png\" rel=\"attachment wp-att-1680\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-1680\" class=\"size-full wp-image-1680\" src=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/start-microarray-fig2.png\" alt=\"start-microarray-fig2\" width=\"647\" height=\"647\" \/><\/a><p id=\"caption-attachment-1680\" class=\"wp-caption-text\">\u56f34 \u30de\u30a4\u30af\u30ed\u30a2\u30ec\u30a4\u3092\u8aad\u307f\u53d6\u3063\u305f\u969b\u306e\u753b\u50cf<\/p><\/div>\n<p>\u3055\u3066\u3053\u306e\u753b\u50cf\u3001\u5de6\u4e0a\u306e\u90e8\u5206\u3092\u30ba\u30fc\u30e0\u3057\u3066\u307f\u308b\u3068\u4ee5\u4e0b\u306e\u3088\u3046\u306a\u6a21\u69d8\u304c\u73fe\u308c\u308b\u3053\u3068\u304c\u5206\u304b\u308a\u307e\u3059\u3002<\/p>\n<div id=\"attachment_1681\" style=\"width: 778px\" class=\"wp-caption aligncenter\"><a href=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/start-microarray-fig3.png\" rel=\"attachment wp-att-1681\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-1681\" class=\"size-full wp-image-1681\" src=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/start-microarray-fig3.png\" alt=\"start-microarray-fig3\" width=\"768\" height=\"280\" \/><\/a><p id=\"caption-attachment-1681\" class=\"wp-caption-text\">\u56f35 \u30de\u30a4\u30af\u30ed\u30a2\u30ec\u30a4\u3092\u8aad\u307f\u53d6\u3063\u305f\u969b\u306e\u753b\u50cf\u306e\u62e1\u5927\u56f3<\/p><\/div>\n<p>\u3053\u306e\u6a21\u69d8\u3001\u300cGeneChip Mouse 430 2\u300d\u3068\u8aad\u3081\u308b\u306e\u304c\u304a\u5206\u304b\u308a\u3067\u3057\u3087\u3046\u304b\uff1f\u5b9f\u306f<strong>\u30de\u30a4\u30af\u30ed\u30a2\u30ec\u30a4\u4e0a\u306b\u306f\u5fc5\u305a\u30cf\u30a4\u30d6\u30ea\u30c0\u30a4\u30bc\u30fc\u30b7\u30e7\u30f3\u304c\u8d77\u3053\u308b\u30dd\u30b8\u30c6\u30a3\u30d6\u30b3\u30f3\u30c8\u30ed\u30fc\u30eb\u306e\u30d7\u30ed\u30fc\u30d6\u304c\u914d\u7f6e\u3055\u308c\u3066\u304a\u308a\u3001\u5de6\u4e0a\u306e\u3053\u306e\u7b87\u6240\u3082\u30b7\u30b0\u30ca\u30eb\u304c\u51fa\u308b\u3088\u3046\u306b\u8a2d\u8a08\u3055\u308c\u3066\u3044\u307e\u3059\u3002<\/strong>\u305d\u306e\u7d50\u679c\u3001\u30dd\u30b8\u30c6\u30a3\u30d6\u30b3\u30f3\u30c8\u30ed\u30fc\u30eb\u306e\u5834\u6240\u304c\u660e\u308b\u304f\u5149\u3063\u3066\u30de\u30a4\u30af\u30ed\u30a2\u30ec\u30a4\u306e\u540d\u79f0\u304c\u6d6e\u304b\u3073\u4e0a\u304c\u3063\u305f\u3068\u3044\u3046\u8a33\u306a\u306e\u3067\u3059\u306d\u3002\u6587\u5b57\u306e\u90e8\u5206\u3092\u3088\u304f\u898b\u3066\u307f\u308b\u3068\u5c0f\u3055\u306a\u30c9\u30c3\u30c8\u304c\u4e26\u3093\u3067\u3044\u308b\u306e\u304c\u5206\u304b\u308b\u304b\u3068\u601d\u3044\u307e\u3059\u304c\u3001\u3053\u306e\u30c9\u30c3\u30c8\u4e00\u3064\u4e00\u3064\u304c\u30bb\u30eb\u306b\u306a\u3063\u3066\u3044\u307e\u3059\u3002\u4e0a\u306e\u5168\u4f53\u753b\u50cf\u3068\u898b\u6bd4\u3079\u3066\u307f\u308b\u3068\u3001\u3044\u304b\u306b\u305f\u304f\u3055\u3093\u306e\u30bb\u30eb\u304c\u3072\u3068\u3064\u306e\u30de\u30a4\u30af\u30ed\u30a2\u30ec\u30a4\u306b\u5bc6\u96c6\u3057\u3066\u3044\u308b\u304b\u304c\u304a\u5206\u304b\u308a\u3044\u305f\u3060\u3051\u308b\u304b\u3068\u601d\u3044\u307e\u3059\u3002<\/p>\n<h2>\u30de\u30a4\u30af\u30ed\u30a2\u30ec\u30a4\u3068\u89e3\u6790\u30bd\u30d5\u30c8\u30a6\u30a7\u30a2<\/h2>\n<p><strong>\u30de\u30a4\u30af\u30ed\u30a2\u30ec\u30a4\u306e\u89e3\u6790\u3067\u306f\u4e0a\u306e\u56f3\u3067\u793a\u3057\u305f\u3088\u3046\u306a\u5927\u91cf\u306e\u30c7\u30fc\u30bf\u3092\u51e6\u7406\u3059\u308b\u305f\u3081\u3001\u5c02\u7528\u306e\u89e3\u6790\u30bd\u30d5\u30c8\u30a6\u30a7\u30a2\u3092\u7528\u3044\u308b\u5fc5\u8981\u304c\u3042\u308a\u307e\u3059\u3002<\/strong>\u5f0a\u793e\u3067\u306f\u5168\u3066\u306e\u7814\u7a76\u8005\u306e\u65b9\u304c\u81ea\u7531\u306b\u89e3\u6790\u3092\u304a\u3053\u306a\u3063\u3066\u3044\u305f\u3060\u3051\u308b\u3088\u3046\u306b\u3001<a href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/life-science\/microarray-analysis.html?CID=gsd_mic_gex_r04_jp_cp0000_pjt0000_gsd00000_0so_blg_op_awa_oc_s00_ma3_Social_LAB\" target=\"_blank\" rel=\"noopener noreferrer\">\u7121\u6599\u306e\u30bd\u30d5\u30c8\u30a6\u30a7\u30a2<\/a>\u3092\u3054\u7528\u610f\u3057\u3066\u3044\u307e\u3059\u3002<\/p>\n<p>\u5f0a\u793e\u306e\u30bd\u30d5\u30c8\u30a6\u30a7\u30a2\u3092\u7528\u3044\u308c\u3070\u3001\u4f8b\u3048\u3070\u4e0b\u56f3\u306e\u3088\u3046\u306a\u30b9\u30ad\u30e3\u30c3\u30bf\u30fc\u30d7\u30ed\u30c3\u30c8\u3092\u7c21\u5358\u306b\u63cf\u304f\u3053\u3068\u304c\u3067\u304d\u307e\u3059\u3002<\/p>\n<div id=\"attachment_1682\" style=\"width: 763px\" class=\"wp-caption aligncenter\"><a href=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/start-microarray-fig4.png\" rel=\"attachment wp-att-1682\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-1682\" class=\"size-full wp-image-1682\" src=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/start-microarray-fig4.png\" alt=\"start-microarray-fig4\" width=\"753\" height=\"700\" \/><\/a><p id=\"caption-attachment-1682\" class=\"wp-caption-text\">\u56f36 \u30de\u30a4\u30af\u30ed\u30a2\u30ec\u30a4\u89e3\u6790\u30bd\u30d5\u30c8\u30a6\u30a7\u30a2\u3092\u7528\u3044\u305f\u30b9\u30ad\u30e3\u30c3\u30bf\u30fc\u30d7\u30ed\u30c3\u30c8<\/p><\/div>\n<p>\u3053\u306e\u56f3\u3067\u306f\u3001\u8d64\u3044\u90e8\u5206\u304c\u767a\u73fe\u306e\u4e0a\u6607\u3057\u305f\u907a\u4f1d\u5b50\u3092\u3001\u7dd1\u8272\u306e\u90e8\u5206\u304c\u767a\u73fe\u306e\u6e1b\u5c11\u3057\u305f\u907a\u4f1d\u5b50\u3092\u8868\u3057\u3066\u3044\u307e\u3059\u3002<\/p>\n<p>\u3042\u308b\u3044\u306f\u3001\u4e0b\u56f3\u306e\u3088\u3046\u306a\u5909\u52d5\u907a\u4f1d\u5b50\u306e\u30af\u30e9\u30b9\u30bf\u30ea\u30f3\u30b0\u306e\u30d2\u30fc\u30c8\u30de\u30c3\u30d7\u8868\u793a\u3082\u4f5c\u6210\u3067\u304d\u307e\u3059\u3002\u30de\u30a4\u30af\u30ed\u30a2\u30ec\u30a4\u306b\u3088\u308b\u767a\u73fe\u89e3\u6790\u3068\u3044\u3046\u3068\u3001\u3053\u306e\u3088\u3046\u306a\u56f3\u3092\u601d\u3044\u6d6e\u304b\u3079\u308b\u65b9\u3082\u591a\u3044\u306e\u3067\u306f\u306a\u3044\u3067\u3057\u3087\u3046\u304b\u3002<\/p>\n<div id=\"attachment_1683\" style=\"width: 728px\" class=\"wp-caption aligncenter\"><a href=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/start-microarray-fig5.png\" rel=\"attachment wp-att-1683\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-1683\" class=\"size-full wp-image-1683\" src=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/start-microarray-fig5.png\" alt=\"start-microarray-fig5\" width=\"718\" height=\"717\" \/><\/a><p id=\"caption-attachment-1683\" class=\"wp-caption-text\">\u56f37 \u30de\u30a4\u30af\u30ed\u30a2\u30ec\u30a4\u89e3\u6790\u30bd\u30d5\u30c8\u30a6\u30a7\u30a2\u3092\u7528\u3044\u305f\u5909\u52d5\u907a\u4f1d\u5b50\u306e\u30af\u30e9\u30b9\u30bf\u30ea\u30f3\u30b0\u306e\u30d2\u30fc\u30c8\u30de\u30c3\u30d7\u8868\u793a<\/p><\/div>\n<p>\u4ee5\u524d\u306f\u3053\u3046\u3057\u305f\u89e3\u6790\u3092\u3059\u308b\u306b\u306f\u9ad8\u4fa1\u306a\u30bd\u30d5\u30c8\u30a6\u30a7\u30a2\u3092\u4f7f\u7528\u3059\u308b\u5fc5\u8981\u304c\u3042\u308a\u307e\u3057\u305f\u304c\u3001<strong>\u5f0a\u793e\u306e\u30de\u30a4\u30af\u30ed\u30a2\u30ec\u30a4\u306a\u3089\u5168\u3066\u7121\u6599\u3067\u89e3\u6790\u3067\u304d\u307e\u3059\u3002<\/strong>\u30bd\u30d5\u30c8\u30a6\u30a7\u30a2\u3084\u30b5\u30f3\u30d7\u30eb\u30c7\u30fc\u30bf\u306f<a href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/life-science\/microarray-analysis.html?CID=gsd_mic_gex_r04_jp_cp0000_pjt0000_gsd00000_0so_blg_op_awa_oc_s00_ma3_Social_LAB\" target=\"_blank\" rel=\"noopener noreferrer\">\u30a6\u30a7\u30d6\u30b5\u30a4\u30c8<\/a>\u304b\u3089\u7121\u6599\u3067\u30c0\u30a6\u30f3\u30ed\u30fc\u30c9\u3067\u304d\u307e\u3059\u306e\u3067\u3001\u3054\u8208\u5473\u306e\u3042\u308b\u65b9\u306f\u662f\u975e\u3068\u3082\u3054\u81ea\u8eab\u306e\u624b\u3067\u8a66\u3055\u308c\u3066\u307f\u3066\u306f\u3044\u304b\u304c\u3067\u3057\u3087\u3046\u304b\uff1f<\/p>\n<h2>\u30de\u30a4\u30af\u30ed\u30a2\u30ec\u30a4\u306e\u5b9f\u9a13\u3092\u59cb\u3081\u308b\u306b\u306f\uff1f<\/h2>\n<p>\u30de\u30a4\u30af\u30ed\u30a2\u30ec\u30a4\u306e\u89e3\u6790\u306b\u306f\u3001\u30b9\u30ad\u30e3\u30ca\u3068\u547c\u3070\u308c\u308b\u8aad\u307f\u53d6\u308a\u88c5\u7f6e\u3092\u7528\u3044\u307e\u3059\u3002<\/p>\n<p>\u5f0a\u793e\u306e\u30de\u30a4\u30af\u30ed\u30a2\u30ec\u30a4\u89e3\u6790\u306b\u306f\u3001Applied Biosystems\u2122 <a href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/life-science\/microarray-analysis\/microarray-analysis-instruments-software-services\/microarray-analysis-instruments\/genechip-scanner.html?CID=gsd_mic_gex_r04_jp_cp0000_pjt0000_gsd00000_0so_blg_op_awa_oc_s00_ma3_Social_LAB\" target=\"_blank\" rel=\"noopener\">GeneChip\u2122 Scanner 3000 7G System<\/a> (GCS3000 System) \u3068\u547c\u3070\u308c\u308b\u88c5\u7f6e\u304c\u4f7f\u308f\u308c\u307e\u3059\u3002<\/p>\n<p><a href=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/47531c928594b978d3090293b4c95db1-1.jpg\"><img loading=\"lazy\" decoding=\"async\" class=\"wp-image-2223 aligncenter\" src=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/47531c928594b978d3090293b4c95db1-1-300x131.jpg\" alt=\"\" width=\"416\" height=\"181\" \/><\/a><\/p>\n<p>GCS3000 System\u306f\u30de\u30a4\u30af\u30ed\u30a2\u30ec\u30a4\u30ab\u30fc\u30c8\u30ea\u30c3\u30b8\u306e\u6d17\u6d44\u67d3\u8272\u3092\u81ea\u52d5\u3067\u884c\u3046\u305f\u3081\u3001\u5b89\u5b9a\u3057\u305f\u89e3\u6790\u7d50\u679c\u3092\u5f97\u308b\u3053\u3068\u304c\u3067\u304d\u307e\u3059\u3002<\/p>\n<p>\u7279\u5fb4\u7684\u306a\u5f62\u3092\u3057\u305f\u88c5\u7f6e\u3067\u3059\u306e\u3067\u3001\u3069\u3053\u304b\u3067\u898b\u304b\u3051\u305f\u8a18\u61b6\u306e\u3042\u308b\u65b9\u3082\u591a\u3044\u306e\u3067\u306f\u306a\u3044\u3067\u3057\u3087\u3046\u304b\u3002\u5171\u901a\u6a5f\u5668\u5ba4\u306a\u3069\u306b\u5c0e\u5165\u3055\u308c\u3066\u3044\u308b\u5834\u5408\u306f\u3001\u5f0a\u793e\u306e\u6700\u65b0\u30de\u30a4\u30af\u30ed\u30a2\u30ec\u30a4\u3067\u3042\u308bApplied Biosystems\u2122 Clariom\u2122 Array\u306a\u3069\u306e\u89e3\u6790\u304c\u3059\u3050\u306b\u884c\u3048\u307e\u3059\u3002\u30de\u30a4\u30af\u30ed\u30a2\u30ec\u30a4\u306b\u3088\u308b\u767a\u73fe\u89e3\u6790\u306b\u8208\u5473\u306e\u3042\u308b\u65b9\u306f\u3001\u305c\u3072\u3068\u3082\u78ba\u8a8d\u3057\u3066\u307f\u3066\u304f\u3060\u3055\u3044\u3002<\/p>\n<p>\u307e\u305f\u30b9\u30ad\u30e3\u30ca\u3092\u6301\u3063\u3066\u3044\u306a\u3044\u5834\u5408\u3067\u3082\u3001<strong>\u30de\u30a4\u30af\u30ed\u30a2\u30ec\u30a4\u306e\u53d7\u8a17\u89e3\u6790\u3092\u884c\u3063\u3066\u3044\u308b\u4f1a\u793e\u306b<\/strong><strong>RNA<\/strong><strong>\u30b5\u30f3\u30d7\u30eb\u3092\u51fa\u3059\u3060\u3051\u3067\u3001\u7c21\u5358\u306b\u7db2\u7f85\u7684\u767a\u73fe\u89e3\u6790\u30c7\u30fc\u30bf\u3092\u624b\u306b\u5165\u308c\u308b\u3053\u3068\u304c\u3067\u304d\u307e\u3059\u3002<\/strong>\u30de\u30a4\u30af\u30ed\u30a2\u30ec\u30a4\u306e\u53d7\u8a17\u89e3\u6790\u306b\u95a2\u3059\u308b\u60c5\u5831\u306f\u4ee5\u4e0b\u306e\u8a18\u4e8b\u306b\u3082\u8a73\u3057\u304f\u8a18\u8f09\u3057\u3066\u3042\u308a\u307e\u3059\u3002<\/p>\n<p><a href=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/points-you-should-know-when-using-contract-analysis-service-of-microarray\/?CID=gsd_mic_gex_r04_jp_cp0000_pjt0000_gsd00000_0so_blg_op_awa_oc_s00_ma3_Social_LAB\" target=\"_blank\" rel=\"noopener\">\u30de\u30a4\u30af\u30ed\u30a2\u30ec\u30a4\u306e\u53d7\u8a17\u89e3\u6790\u3092\u5229\u7528\u3059\u308b\u969b\u306b\u77e5\u3063\u3066\u304a\u304d\u305f\u3044\u30dd\u30a4\u30f3\u30c8<\/a><\/p>\n<h2>\u307e\u3068\u3081<\/h2>\n<p>\u4eca\u56de\u306f\u30de\u30a4\u30af\u30ed\u30a2\u30ec\u30a4\u3092\u4f7f\u3063\u305f\u767a\u73fe\u89e3\u6790\u306b\u3064\u3044\u3066\u3001\u305d\u306e\u539f\u7406\u3084\u89e3\u6790\u306e\u65b9\u6cd5\u306b\u3064\u3044\u3066\u7c21\u5358\u306b\u307e\u3068\u3081\u3066\u307f\u307e\u3057\u305f\u3002\u672c\u6587\u4e2d\u3067\u3082\u3054\u7d39\u4ecb\u3057\u305f\u3088\u3046\u306b\u3001\u6700\u8fd1\u3067\u306f\u6b21\u4e16\u4ee3\u578b\u8d85\u9ad8\u5bc6\u5ea6\u30de\u30a4\u30af\u30ed\u30a2\u30ec\u30a4\u306e\u3088\u3046\u306a\u65b0\u88fd\u54c1\u3082\u767b\u5834\u3057\u3066\u304d\u3066\u304a\u308a\u3001\u305d\u306e\u7528\u9014\u306f\u307e\u3059\u307e\u3059\u62e1\u5927\u3057\u3066\u3044\u307e\u3059\u3002\u3053\u308c\u3092\u6a5f\u4f1a\u306b\u3001\u662f\u975e\u3068\u3082\u6700\u65b0\u306e\u767a\u73fe\u89e3\u6790\u6280\u8853\u306b\u3064\u3044\u3066\u306e\u60c5\u5831\u306b\u3082\u89e6\u308c\u3066\u307f\u3066\u304f\u3060\u3055\u3044\u3002<\/p>\n<h2>\u30de\u30a4\u30af\u30ed\u30a2\u30ec\u30a4\u7121\u6599\u51fa\u5f35\u30bb\u30df\u30ca\u30fc\u306e\u3054\u6848\u5185<\/h2>\n<p>\u30de\u30a4\u30af\u30ed\u30a2\u30ec\u30a4\u304c\u767b\u5834\u3057\u3066\u304b\u3089\u3001\u6570\u5341\u5e74\u3068\u3044\u3046\u6708\u65e5\u304c\u305f\u3061\u307e\u3057\u305f\u30022000\u5e74\u4ee3\u521d\u3081\u306b\u306f\u6570\u767e\u4e07\u5186\u307b\u3069\u3057\u305f\u89e3\u6790\u30b3\u30b9\u30c8\u3082\u3001\u4eca\u3067\u306f\u6570\u5341\u5206\u306e\u4e00\u4ee5\u4e0b\u306b\u307e\u3067\u4e0b\u304c\u3063\u3066\u3044\u307e\u3059\u3002\u304b\u3064\u3066\u306f\u4e00\u90e8\u306e\u9650\u3089\u308c\u305f\u7814\u7a76\u8005\u3060\u3051\u304c\u884c\u3048\u305f\u7db2\u7f85\u7684\u767a\u73fe\u89e3\u6790\u304c\u3001\u3044\u307e\u3084\u8ab0\u3067\u3082\u7c21\u5358\u306b\u4f4e\u30b3\u30b9\u30c8\u3067\u5b9f\u65bd\u3067\u304d\u308b\u3088\u3046\u306b\u306a\u308a\u307e\u3057\u305f\u3002<\/p>\n<p>\u5f53\u793e\u3067\u306f\u3001\u3053\u306e\u30c6\u30af\u30ce\u30ed\u30b8\u30fc\u3092\u3088\u308a\u591a\u304f\u306e\u304a\u5ba2\u69d8\u306b\u77e5\u3063\u3066\u3044\u305f\u3060\u304f\u305f\u3081\u306b\u3001<strong>\u7121\u6599\u306e\u51fa\u5f35\u30bb\u30df\u30ca\u30fc\u3092\u958b\u50ac\u3057\u3066\u3044\u307e\u3059\u3002<\/strong><\/p>\n<p>\u30fb\u6700\u65b0\u306e\u30de\u30a4\u30af\u30ed\u30a2\u30ec\u30a4\u306b\u95a2\u3059\u308b\u52d5\u5411\u306b\u8208\u5473\u304c\u3042\u308b<\/p>\n<p>\u30fb\u6b21\u4e16\u4ee3\u30b7\u30fc\u30b1\u30f3\u30b5\u3088\u308a\u3082\u7cbe\u5ea6\u306e\u826f\u3044\u89e3\u6790\u304c\u3067\u304d\u308b\u3068\u805e\u3044\u305f\u3051\u3069\u3001\u672c\u5f53\uff1f<\/p>\n<p>\u30fb\u89e3\u6790\u3059\u308b\u306e\u306b\u3069\u306e\u7a0b\u5ea6\u306e\u30b3\u30b9\u30c8\u304c\u304b\u304b\u308b\u306e\u304b\u77e5\u308a\u305f\u3044<\/p>\n<p>\u3053\u306e\u3088\u3046\u306a\u7591\u554f\u3084\u8208\u5473\u3092\u304a\u6301\u3061\u306e\u304a\u5ba2\u69d8\u306f\u3001\u305c\u3072\u3068\u3082\u30de\u30a4\u30af\u30ed\u30a2\u30ec\u30a4\u51fa\u5f35\u30bb\u30df\u30ca\u30fc\u3092\u304a\u8a66\u3057\u304f\u3060\u3055\u3044\u3002\u5730\u57df\u3084\u4eba\u6570\u3092\u554f\u308f\u305a\u3001\u7121\u6599\u3067\u3054\u8a2a\u554f\u3044\u305f\u3057\u307e\u3059\u3002<\/p>\n<p>\u3054\u8208\u5473\u306e\u3042\u308b\u65b9\u306f\u3001\u3053\u3061\u3089\u306e<a href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/technical-resources\/seminars\/microarray-seminar.html?cid=gsd_mic_gex_r04_jp_cp0000_pjt0000_gsd00000_0so_blg_op_awa_oc_s00_ma3_Social_LAB\" target=\"_blank\" rel=\"noopener\">\u30d5\u30a9\u30fc\u30e0<\/a>\u3088\u308a\u3054\u9023\u7d61\u304f\u3060\u3055\u3044\u3002<\/p>\n<h3>\u30de\u30a4\u30af\u30ed\u30a2\u30ec\u30a4 \u304a\u8a66\u3057\u89e3\u6790<\/h3>\n<p>\u30b5\u30fc\u30e2\u30d5\u30a3\u30c3\u30b7\u30e3\u30fc\u306b\u306f\u300c\u304a\u8a66\u3057\u6709\u511f\u89e3\u6790\u30b5\u30fc\u30d3\u30b9\u300d\u3082\u3054\u3056\u3044\u307e\u3059\u3002\u3053\u306e\u6a5f\u4f1a\u306b\u4e00\u5ea6\u3001\u5f0a\u793e\u306e\u30a2\u30ec\u30a4\u3092\u304a\u8a66\u3057\u304f\u3060\u3055\u3044\u3002<\/p>\n<p><a class=\"btn btn-red\" href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/products-and-services\/services\/technical-services\/trial-service\/microarray-analysis.html?CID=gsd_mic_gex_r04_jp_cp0000_pjt0000_gsd00000_0so_blg_op_awa_oc_s00_ma3_Social_LAB\" target=\"_blank\" rel=\"noopener noreferrer\">\u304a\u8a66\u3057\u6709\u511f\u89e3\u6790\u30b5\u30fc\u30d3\u30b9\u306f\u3053\u3061\u3089<\/a><\/p>\n<p>\u7814\u7a76\u7528\u306b\u306e\u307f\u4f7f\u7528\u3067\u304d\u307e\u3059\u3002\u8a3a\u65ad\u76ee\u7684\u304a\u3088\u3073\u305d\u306e\u624b\u7d9a\u304d\u4e0a\u3067\u306e\u4f7f\u7528\u306f\u3067\u304d\u307e\u305b\u3093\u3002<\/p>\n","protected":false},"excerpt":{"rendered":"<p>\u5f0a\u793e\u306e\u4e3b\u8981\u306a\u88fd\u54c1\u3067\u3042\u308b\u30de\u30a4\u30af\u30ed\u30a2\u30ec\u30a4\u306f\u3001\u305d\u306e\u767b\u5834\u4ee5\u6765\u69d8\u3005\u306a\u5206\u91ce\u3084\u30a2\u30d7\u30ea\u30b1\u30fc\u30b7\u30e7\u30f3\u3067\u4f7f\u308f\u308c\u3066\u304d\u3066\u3044\u307e\u3059\u3002\u4eca\u56de\u306f\u3001\u305d\u3093\u306a\u30de\u30a4\u30af\u30ed\u30a2\u30ec\u30a4\u89e3\u6790\u306e\u4e2d\u304b\u3089\u3001\u3082\u3063\u3068\u3082\u4ee3\u8868\u7684\u306a\u30a2\u30d7\u30ea\u30b1\u30fc\u30b7\u30e7\u30f3\u3067\u3042\u308b\u767a\u73fe\u89e3\u6790\u306b\u3064\u3044\u3066\u3054\u7d39\u4ecb\u3057\u307e\u3059\u3002<\/p>\n","protected":false},"author":988,"featured_media":2965,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_monsterinsights_skip_tracking":false,"_genesis_hide_title":false,"_genesis_hide_breadcrumbs":false,"_genesis_hide_singular_image":false,"_genesis_hide_footer_widgets":false,"_genesis_custom_body_class":"","_genesis_custom_post_class":"","_genesis_layout":"","_jetpack_newsletter_access":"","_jetpack_dont_email_post_to_subs":false,"_jetpack_newsletter_tier_id":0,"_jetpack_memberships_contains_paywalled_content":false,"_jetpack_feature_clip_id":0,"_jetpack_memberships_contains_paid_content":false,"footnotes":"","jetpack_post_was_ever_published":false},"categories":[156],"tags":[71],"division":[],"class_list":["post-574","post","type-post","status-publish","format-standard","has-post-thumbnail","category-mol-bio","tag-microarray","entry"],"_selected_authors":"","_selected_reviewers":"","acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v27.8 (Yoast SEO v27.8) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>\u30de\u30a4\u30af\u30ed\u30a2\u30ec\u30a4\u3068\u306f\uff1f\uff5c\u30de\u30a4\u30af\u30ed\u30a2\u30ec\u30a4\u3092\u7528\u3044\u305f\u767a\u73fe\u89e3\u6790\u306e\u539f\u7406\u3068\u89e3\u6790\u65b9\u6cd5 - Learning at the Bench<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/start-microarray\/\" \/>\n<meta property=\"og:locale\" content=\"ja_JP\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"\u30de\u30a4\u30af\u30ed\u30a2\u30ec\u30a4\u3068\u306f\uff1f\uff5c\u30de\u30a4\u30af\u30ed\u30a2\u30ec\u30a4\u3092\u7528\u3044\u305f\u767a\u73fe\u89e3\u6790\u306e\u539f\u7406\u3068\u89e3\u6790\u65b9\u6cd5\" \/>\n<meta property=\"og:description\" content=\"\u5f0a\u793e\u306e\u4e3b\u8981\u306a\u88fd\u54c1\u3067\u3042\u308b\u30de\u30a4\u30af\u30ed\u30a2\u30ec\u30a4\u306f\u3001\u305d\u306e\u767b\u5834\u4ee5\u6765\u69d8\u3005\u306a\u5206\u91ce\u3084\u30a2\u30d7\u30ea\u30b1\u30fc\u30b7\u30e7\u30f3\u3067\u4f7f\u308f\u308c\u3066\u304d\u3066\u3044\u307e\u3059\u3002\u4eca\u56de\u306f\u3001\u305d\u3093\u306a\u30de\u30a4\u30af\u30ed\u30a2\u30ec\u30a4\u89e3\u6790\u306e\u4e2d\u304b\u3089\u3001\u3082\u3063\u3068\u3082\u4ee3\u8868\u7684\u306a\u30a2\u30d7\u30ea\u30b1\u30fc\u30b7\u30e7\u30f3\u3067\u3042\u308b\u767a\u73fe\u89e3\u6790\u306b\u3064\u3044\u3066\u3054\u7d39\u4ecb\u3057\u307e\u3059\u3002\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/start-microarray\/\" \/>\n<meta property=\"og:site_name\" content=\"Learning at the Bench\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/ThermoFisherJapan\" \/>\n<meta property=\"article:published_time\" content=\"2017-12-18T00:00:00+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2025-03-10T01:56:15+00:00\" \/>\n<meta property=\"og:image\" content=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/start-microarray-title.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"1200\" \/>\n\t<meta property=\"og:image:height\" content=\"631\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"LATB Staff\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:creator\" content=\"@ThermoFisherJP\" \/>\n<meta name=\"twitter:site\" content=\"@ThermoFisherJP\" \/>\n<meta name=\"twitter:label1\" content=\"\u57f7\u7b46\u8005\" \/>\n\t<meta name=\"twitter:data1\" content=\"LATB Staff\" \/>\n\t<meta name=\"twitter:label2\" content=\"\u63a8\u5b9a\u8aad\u307f\u53d6\u308a\u6642\u9593\" \/>\n\t<meta name=\"twitter:data2\" content=\"17\u5206\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/start-microarray\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/start-microarray\\\/\"},\"author\":{\"name\":\"LATB Staff\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#\\\/schema\\\/person\\\/201e6a5abb838fa34e8ff0174b015d36\"},\"headline\":\"\u30de\u30a4\u30af\u30ed\u30a2\u30ec\u30a4\u3068\u306f\uff1f\uff5c\u30de\u30a4\u30af\u30ed\u30a2\u30ec\u30a4\u3092\u7528\u3044\u305f\u767a\u73fe\u89e3\u6790\u306e\u539f\u7406\u3068\u89e3\u6790\u65b9\u6cd5\",\"datePublished\":\"2017-12-18T00:00:00+00:00\",\"dateModified\":\"2025-03-10T01:56:15+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/start-microarray\\\/\"},\"wordCount\":101,\"commentCount\":0,\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/start-microarray\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2019\\\/07\\\/start-microarray-title.jpg\",\"keywords\":[\"\u30de\u30a4\u30af\u30ed\u30a2\u30ec\u30a4\"],\"articleSection\":[\"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023\"],\"inLanguage\":\"ja\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/start-microarray\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/start-microarray\\\/\",\"url\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/start-microarray\\\/\",\"name\":\"\u30de\u30a4\u30af\u30ed\u30a2\u30ec\u30a4\u3068\u306f\uff1f\uff5c\u30de\u30a4\u30af\u30ed\u30a2\u30ec\u30a4\u3092\u7528\u3044\u305f\u767a\u73fe\u89e3\u6790\u306e\u539f\u7406\u3068\u89e3\u6790\u65b9\u6cd5 - Learning at the Bench\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/start-microarray\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/start-microarray\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2019\\\/07\\\/start-microarray-title.jpg\",\"datePublished\":\"2017-12-18T00:00:00+00:00\",\"dateModified\":\"2025-03-10T01:56:15+00:00\",\"author\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#\\\/schema\\\/person\\\/201e6a5abb838fa34e8ff0174b015d36\"},\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/start-microarray\\\/#breadcrumb\"},\"inLanguage\":\"ja\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/start-microarray\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"ja\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/start-microarray\\\/#primaryimage\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2019\\\/07\\\/start-microarray-title.jpg\",\"contentUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2019\\\/07\\\/start-microarray-title.jpg\",\"width\":1200,\"height\":631,\"caption\":\"start-microarray-title\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/start-microarray\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"\u30de\u30a4\u30af\u30ed\u30a2\u30ec\u30a4\u3068\u306f\uff1f\uff5c\u30de\u30a4\u30af\u30ed\u30a2\u30ec\u30a4\u3092\u7528\u3044\u305f\u767a\u73fe\u89e3\u6790\u306e\u539f\u7406\u3068\u89e3\u6790\u65b9\u6cd5\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#website\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/\",\"name\":\"Learning at the Bench\",\"description\":\"\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"ja\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#\\\/schema\\\/person\\\/201e6a5abb838fa34e8ff0174b015d36\",\"name\":\"LATB Staff\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"ja\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/8803277856c8b753feb4217dff0f9953327452df1a615c3c88b2f9864efb2ddd?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/8803277856c8b753feb4217dff0f9953327452df1a615c3c88b2f9864efb2ddd?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/8803277856c8b753feb4217dff0f9953327452df1a615c3c88b2f9864efb2ddd?s=96&d=mm&r=g\",\"caption\":\"LATB Staff\"},\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/author\\\/latbstaff\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"\u30de\u30a4\u30af\u30ed\u30a2\u30ec\u30a4\u3068\u306f\uff1f\uff5c\u30de\u30a4\u30af\u30ed\u30a2\u30ec\u30a4\u3092\u7528\u3044\u305f\u767a\u73fe\u89e3\u6790\u306e\u539f\u7406\u3068\u89e3\u6790\u65b9\u6cd5 - Learning at the Bench","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/start-microarray\/","og_locale":"ja_JP","og_type":"article","og_title":"\u30de\u30a4\u30af\u30ed\u30a2\u30ec\u30a4\u3068\u306f\uff1f\uff5c\u30de\u30a4\u30af\u30ed\u30a2\u30ec\u30a4\u3092\u7528\u3044\u305f\u767a\u73fe\u89e3\u6790\u306e\u539f\u7406\u3068\u89e3\u6790\u65b9\u6cd5","og_description":"\u5f0a\u793e\u306e\u4e3b\u8981\u306a\u88fd\u54c1\u3067\u3042\u308b\u30de\u30a4\u30af\u30ed\u30a2\u30ec\u30a4\u306f\u3001\u305d\u306e\u767b\u5834\u4ee5\u6765\u69d8\u3005\u306a\u5206\u91ce\u3084\u30a2\u30d7\u30ea\u30b1\u30fc\u30b7\u30e7\u30f3\u3067\u4f7f\u308f\u308c\u3066\u304d\u3066\u3044\u307e\u3059\u3002\u4eca\u56de\u306f\u3001\u305d\u3093\u306a\u30de\u30a4\u30af\u30ed\u30a2\u30ec\u30a4\u89e3\u6790\u306e\u4e2d\u304b\u3089\u3001\u3082\u3063\u3068\u3082\u4ee3\u8868\u7684\u306a\u30a2\u30d7\u30ea\u30b1\u30fc\u30b7\u30e7\u30f3\u3067\u3042\u308b\u767a\u73fe\u89e3\u6790\u306b\u3064\u3044\u3066\u3054\u7d39\u4ecb\u3057\u307e\u3059\u3002","og_url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/start-microarray\/","og_site_name":"Learning at the Bench","article_publisher":"https:\/\/www.facebook.com\/ThermoFisherJapan","article_published_time":"2017-12-18T00:00:00+00:00","article_modified_time":"2025-03-10T01:56:15+00:00","og_image":[{"width":1200,"height":631,"url":"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/start-microarray-title.jpg","type":"image\/jpeg"}],"author":"LATB Staff","twitter_card":"summary_large_image","twitter_creator":"@ThermoFisherJP","twitter_site":"@ThermoFisherJP","twitter_misc":{"\u57f7\u7b46\u8005":"LATB Staff","\u63a8\u5b9a\u8aad\u307f\u53d6\u308a\u6642\u9593":"17\u5206"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/start-microarray\/#article","isPartOf":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/start-microarray\/"},"author":{"name":"LATB Staff","@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#\/schema\/person\/201e6a5abb838fa34e8ff0174b015d36"},"headline":"\u30de\u30a4\u30af\u30ed\u30a2\u30ec\u30a4\u3068\u306f\uff1f\uff5c\u30de\u30a4\u30af\u30ed\u30a2\u30ec\u30a4\u3092\u7528\u3044\u305f\u767a\u73fe\u89e3\u6790\u306e\u539f\u7406\u3068\u89e3\u6790\u65b9\u6cd5","datePublished":"2017-12-18T00:00:00+00:00","dateModified":"2025-03-10T01:56:15+00:00","mainEntityOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/start-microarray\/"},"wordCount":101,"commentCount":0,"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/start-microarray\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/start-microarray-title.jpg","keywords":["\u30de\u30a4\u30af\u30ed\u30a2\u30ec\u30a4"],"articleSection":["\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023"],"inLanguage":"ja","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/start-microarray\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/start-microarray\/","url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/start-microarray\/","name":"\u30de\u30a4\u30af\u30ed\u30a2\u30ec\u30a4\u3068\u306f\uff1f\uff5c\u30de\u30a4\u30af\u30ed\u30a2\u30ec\u30a4\u3092\u7528\u3044\u305f\u767a\u73fe\u89e3\u6790\u306e\u539f\u7406\u3068\u89e3\u6790\u65b9\u6cd5 - Learning at the Bench","isPartOf":{"@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/start-microarray\/#primaryimage"},"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/start-microarray\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/start-microarray-title.jpg","datePublished":"2017-12-18T00:00:00+00:00","dateModified":"2025-03-10T01:56:15+00:00","author":{"@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#\/schema\/person\/201e6a5abb838fa34e8ff0174b015d36"},"breadcrumb":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/start-microarray\/#breadcrumb"},"inLanguage":"ja","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/start-microarray\/"]}]},{"@type":"ImageObject","inLanguage":"ja","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/start-microarray\/#primaryimage","url":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/start-microarray-title.jpg","contentUrl":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/start-microarray-title.jpg","width":1200,"height":631,"caption":"start-microarray-title"},{"@type":"BreadcrumbList","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/start-microarray\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/"},{"@type":"ListItem","position":2,"name":"\u30de\u30a4\u30af\u30ed\u30a2\u30ec\u30a4\u3068\u306f\uff1f\uff5c\u30de\u30a4\u30af\u30ed\u30a2\u30ec\u30a4\u3092\u7528\u3044\u305f\u767a\u73fe\u89e3\u6790\u306e\u539f\u7406\u3068\u89e3\u6790\u65b9\u6cd5"}]},{"@type":"WebSite","@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#website","url":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/","name":"Learning at the Bench","description":"","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"ja"},{"@type":"Person","@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#\/schema\/person\/201e6a5abb838fa34e8ff0174b015d36","name":"LATB Staff","image":{"@type":"ImageObject","inLanguage":"ja","@id":"https:\/\/secure.gravatar.com\/avatar\/8803277856c8b753feb4217dff0f9953327452df1a615c3c88b2f9864efb2ddd?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/8803277856c8b753feb4217dff0f9953327452df1a615c3c88b2f9864efb2ddd?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/8803277856c8b753feb4217dff0f9953327452df1a615c3c88b2f9864efb2ddd?s=96&d=mm&r=g","caption":"LATB Staff"},"url":"https:\/\/admin.acceleratingscience.com\/author\/latbstaff\/"}]}},"taxonomy_info":{"category":[{"value":156,"label":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023"}],"post_tag":[{"value":71,"label":"\u30de\u30a4\u30af\u30ed\u30a2\u30ec\u30a4"}]},"featured_image_src_large":["https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/start-microarray-title-1024x538.jpg",760,399,true],"author_info":{"display_name":"LATB Staff","author_link":"https:\/\/admin.acceleratingscience.com\/author\/latbstaff\/"},"comment_info":0,"category_info":[{"term_id":156,"name":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","slug":"mol-bio","term_group":0,"term_taxonomy_id":156,"taxonomy":"category","description":"","parent":0,"count":540,"filter":"raw","meta":[],"cat_ID":156,"category_count":540,"category_description":"","cat_name":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","category_nicename":"mol-bio","category_parent":0}],"tag_info":[{"term_id":71,"name":"\u30de\u30a4\u30af\u30ed\u30a2\u30ec\u30a4","slug":"microarray","term_group":0,"term_taxonomy_id":71,"taxonomy":"post_tag","description":"","parent":0,"count":28,"filter":"raw","meta":[]}],"jetpack-related-posts":[{"id":20152,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/exosome-nucleic-acid-purification-ts-r-25017\/","url_meta":{"origin":574,"position":0},"title":"\u3010\u7b2c3\u56de\u3011\u201cRNA cargo\u201d\u306e\u7cbe\u88fd\u3068\u5b9a\u91cf\u89e3\u6790","author":"LatB Staff","date":"2026\u5e745\u670813\u65e5","format":false,"excerpt":"\u7b2c2\u56de\u3067\u306f\u3001\u57f9\u990a\u4e0a\u6e05\u3084\u3055\u307e\u3056\u307e\u306a\u4f53\u6db2\u30b5\u30f3\u30d7\u30eb\u304b\u3089\u306e\u30a8\u30af\u30bd\u30bd\u30fc\u30e0\u306e\u6fc3\u7e2e\u30fb\u56de\u53ce\u65b9\u6cd5\u306b\u3064\u3044\u3066\u7d39\u4ecb\u3057\u307e\u3057\u305f\u304c\u2026","rel":"","context":"\u305d\u306e\u4ed6","block_context":{"text":"\u305d\u306e\u4ed6","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/else\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/f17931341a23d82235760ed66ded9c41.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/f17931341a23d82235760ed66ded9c41.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/f17931341a23d82235760ed66ded9c41.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/f17931341a23d82235760ed66ded9c41.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/f17931341a23d82235760ed66ded9c41.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/f17931341a23d82235760ed66ded9c41.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":24545,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/digital-pcr-gene-expression-gsd-ts-sd-25082\/","url_meta":{"origin":574,"position":1},"title":"\u3010Absolute Q\u30c7\u30b8\u30bf\u30ebPCR\u30b7\u30b9\u30c6\u30e0\u306e\u6d3b\u7528\u4f8b\u3011\u30df\u30c8\u30b3\u30f3\u30c9\u30ea\u30a2DNA\u306e\u5b9a\u91cf","author":"LatB Staff","date":"2026\u5e741\u670816\u65e5","format":false,"excerpt":"Applied Biosystems\u2122 QuantStudio\u2122 Absolute Q\u2122 \u30c7\u30b8\u30bf\u30ebP\u2026","rel":"","context":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","block_context":{"text":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/mol-bio\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/12\/digital-pcr-gene-expression-gsd-ts-sd-25082_eyecatch.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/12\/digital-pcr-gene-expression-gsd-ts-sd-25082_eyecatch.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/12\/digital-pcr-gene-expression-gsd-ts-sd-25082_eyecatch.jpg?resize=525%2C300&ssl=1 1.5x"},"classes":[]},{"id":24606,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/transfection-antibody-bid-ts-mbr-26004\/","url_meta":{"origin":574,"position":2},"title":"\u7d30\u80de\u5185\u30bf\u30f3\u30d1\u30af\u8cea\u9664\u53bb\u30b7\u30b9\u30c6\u30e0\uff08Trim-Away\u6cd5\uff09\u306e\u7d39\u4ecb\uff5e\u30a8\u30ec\u30af\u30c8\u30ed\u30dd\u30ec\u30fc\u30b7\u30e7\u30f3\u6a5f\u5668\u3092\u4f7f\u7528\u3057\u3066\uff5e","author":"LatB Staff","date":"2026\u5e742\u67084\u65e5","format":false,"excerpt":"2018\u5e74\u306e\u6587\u732e(1)\u3067\u7d30\u80de\u5185\u306e\u5185\u5728\u6027\u30bf\u30f3\u30d1\u30af\u8cea\u3092\u76f4\u63a5\u5206\u89e3\u3059\u308b\u3001Trim-Away\u6cd5\u304c\u7d39\u4ecb\u3055\u308c\u307e\u3057\u305f\u2026","rel":"","context":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","block_context":{"text":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/mol-bio\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/01\/transfection-antibody-bid-ts-mbr-26004_eyecatch.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/01\/transfection-antibody-bid-ts-mbr-26004_eyecatch.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/01\/transfection-antibody-bid-ts-mbr-26004_eyecatch.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/01\/transfection-antibody-bid-ts-mbr-26004_eyecatch.jpg?resize=700%2C400&ssl=1 2x"},"classes":[]},{"id":24187,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/ngs-gene-expression-csd-ts-ion-25073\/","url_meta":{"origin":574,"position":3},"title":"\u3010\u3084\u3063\u3066\u307f\u305f\u3011\u5fae\u91cf\u30fb\u5206\u89e3RNA\u306b\u3088\u308b\u767a\u73fe\u89e3\u6790\u306e\u6700\u9069\u89e3\u306f\uff1fRNA-Seq\u3068Ion AmpliSeq Transcriptome\u3092\u6bd4\u3079\u3066\u307f\u305f","author":"LatB Staff","date":"2025\u5e7411\u670828\u65e5","format":false,"excerpt":"\u6b21\u4e16\u4ee3\u30b7\u30fc\u30b1\u30f3\u30b5\u3067\u306e\u767a\u73fe\u89e3\u6790\u306b\u53d6\u308a\u7d44\u3080\u969b\u3001RNA\u30b5\u30f3\u30d7\u30eb\u304c\u300c\u5c11\u306a\u3059\u304e\u308b\u300d\u300c\u5206\u89e3\u3057\u3066\u3044\u308b\u300d\u3068\u3044\u3046\u72b6\u6cc1\u306f\u2026","rel":"","context":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","block_context":{"text":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/mol-bio\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/11\/ngs-gene-expression-csd-ts-ion-25073_eyecatch-scaled.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/11\/ngs-gene-expression-csd-ts-ion-25073_eyecatch-scaled.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/11\/ngs-gene-expression-csd-ts-ion-25073_eyecatch-scaled.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/11\/ngs-gene-expression-csd-ts-ion-25073_eyecatch-scaled.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/11\/ngs-gene-expression-csd-ts-ion-25073_eyecatch-scaled.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/11\/ngs-gene-expression-csd-ts-ion-25073_eyecatch-scaled.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":25090,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/battery-development-elemental-analysis-csm-26016\/","url_meta":{"origin":574,"position":4},"title":"\u30ea\u30c1\u30a6\u30e0\u30a4\u30aa\u30f3\u96fb\u6c60\u88fd\u9020\uff1a\u4f7f\u7528\u3055\u308c\u308b\u5316\u5b66\u5206\u6790\u6280\u8853","author":"LatB Staff","date":"2026\u5e744\u670820\u65e5","format":false,"excerpt":"\u9ad8\u6027\u80fd\u96fb\u6c60\u306b\u5bfe\u3059\u308b\u9700\u8981\u306e\u6025\u5897\u306f\u3001\u751f\u7523\u306e\u3042\u3089\u3086\u308b\u6bb5\u968e\u306b\u304a\u3051\u308b\u5927\u898f\u6a21\u306a\u6295\u8cc7\u3092\u4fc3\u3057\u3066\u3044\u307e\u3059\u3002\u96fb\u6c60\u7814\u7a76\u304a\u3088\u3073\u2026","rel":"","context":"\u5206\u6790\u30fb\u6e2c\u5b9a\u95a2\u9023","block_context":{"text":"\u5206\u6790\u30fb\u6e2c\u5b9a\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/analysis\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/04\/battery-development-elemental-analysis-csm-26016_eyecatch.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/04\/battery-development-elemental-analysis-csm-26016_eyecatch.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/04\/battery-development-elemental-analysis-csm-26016_eyecatch.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/04\/battery-development-elemental-analysis-csm-26016_eyecatch.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/04\/battery-development-elemental-analysis-csm-26016_eyecatch.jpg?resize=1050%2C600&ssl=1 3x"},"classes":[]},{"id":24953,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/ngs-gene-expression-csd-ts-ion-26011\/","url_meta":{"origin":574,"position":5},"title":"\u30e9\u30a4\u30d6\u30e9\u30ea\u30fc\u8abf\u88fd\u306e\u81ea\u52d5\u5316\u3067NGS\u306e\u53ef\u80fd\u6027\u3092\u5e83\u3052\u308b\u2015Ion Chef\u30b7\u30b9\u30c6\u30e0\u304c\u5909\u3048\u308b\u7814\u7a76\u5ba4\u306e\u30ef\u30fc\u30af\u30d5\u30ed\u30fc","author":"LatB Staff","date":"2026\u5e744\u670810\u65e5","format":false,"excerpt":"\u524d\u51e6\u7406\u306e\u81ea\u52d5\u5316\u304c\u3001NGS\u306e\u65b0\u3057\u3044\u6a19\u6e96\u3092\u3064\u304f\u308b\u6b21\u4e16\u4ee3\u30b7\u30fc\u30b1\u30f3\u30b7\u30f3\u30b0\uff08NGS\uff09\u304c\u65e5\u5e38\u7684\u306a\u7814\u7a76\u30c4\u30fc\u30eb\u3068\u306a\u3063\u2026","rel":"","context":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","block_context":{"text":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/mol-bio\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/02\/ngs-gene-expression-csd-ts-ion-26011_eyecatch.jpeg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/02\/ngs-gene-expression-csd-ts-ion-26011_eyecatch.jpeg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/02\/ngs-gene-expression-csd-ts-ion-26011_eyecatch.jpeg?resize=525%2C300&ssl=1 1.5x"},"classes":[]}],"jetpack_sharing_enabled":true,"amp_enabled":true,"jetpack_featured_media_url":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/start-microarray-title.jpg","_links":{"self":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/posts\/574","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/users\/988"}],"replies":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/comments?post=574"}],"version-history":[{"count":0,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/posts\/574\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/media\/2965"}],"wp:attachment":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/media?parent=574"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/categories?post=574"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/tags?post=574"},{"taxonomy":"division","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/division?post=574"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}