{"id":5753,"date":"2019-11-11T16:16:18","date_gmt":"2019-11-11T07:16:18","guid":{"rendered":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/?p=5753"},"modified":"2023-12-28T10:21:06","modified_gmt":"2023-12-28T01:21:06","slug":"%e6%ac%a1%e4%b8%96%e4%bb%a3%e3%82%b7%e3%83%bc%e3%82%b1%e3%83%b3%e3%82%b5%ef%bd%9e%e5%80%8b%e5%88%a5%e5%8c%96%e5%8c%bb%e7%99%82%e3%81%a8%e3%81%8c%e3%82%93%e3%82%b2%e3%83%8e%e3%83%a0%e7%a0%94","status":"publish","type":"post","link":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/%e6%ac%a1%e4%b8%96%e4%bb%a3%e3%82%b7%e3%83%bc%e3%82%b1%e3%83%b3%e3%82%b5%ef%bd%9e%e5%80%8b%e5%88%a5%e5%8c%96%e5%8c%bb%e7%99%82%e3%81%a8%e3%81%8c%e3%82%93%e3%82%b2%e3%83%8e%e3%83%a0%e7%a0%94\/","title":{"rendered":"\u6b21\u4e16\u4ee3\u30b7\u30fc\u30b1\u30f3\u30b5\u3000\uff5e\u500b\u5225\u5316\u533b\u7642\u3068\u304c\u3093\u30b2\u30ce\u30e0\u7814\u7a76\uff5e"},"content":{"rendered":"<p>\u8fd1\u5e74\u3001\u304c\u3093\u306a\u3069\u306e\u75be\u60a3\u306b\u5bfe\u3059\u308b\u5206\u5b50\u6a19\u7684\u6cbb\u7642\u85ac\u306e\u958b\u767a\u306f\u3081\u3056\u307e\u3057\u304f\u3001\u591a\u304f\u306e\u60a3\u8005\u306b\u3068\u3063\u3066\u5e0c\u671b\u306e\u5149\u3068\u306a\u3063\u3066\u3044\u307e\u3059\u3002\u305d\u306e\u4e00\u65b9\u3067\u3001\u5b9f\u969b\u306b\u85ac\u5264\u3092\u9069\u7528\u3067\u304d\u308b\u60a3\u8005\u3084\u3001\u85ac\u5264\u306e\u52b9\u679c\u304c\u898b\u3089\u308c\u308b\u60a3\u8005\u306f\u4e00\u90e8\u306b\u9650\u3089\u308c\u308b\u3053\u3068\u304c\u308f\u304b\u3063\u3066\u304d\u307e\u3057\u305f\u3002\u307e\u305f\u3001\u5e0c\u5c11\u75be\u60a3\u306a\u3069 \u3067\u306f\u3001\u3069\u306e\u3088\u3046\u306a\u907a\u4f1d\u5b50\u7570\u5e38\u304c\u539f\u56e0\u3068\u306a\u3063\u3066\u75be\u60a3\u304c\u767a\u75c7\u3059\u308b\u306e\u304b\u308f\u304b\u3089\u306a\u3044\u305f\u3081\u3001\u8a3a\u65ad\u30fb\u6cbb\u7642\u65b9\u91dd\u306e\u6c7a\u5b9a\u306a\u3069\u304c\u56f0\u96e3\u3067\u3042\u308b\u75be\u60a3\u304c\u591a\u6570\u3042\u308a\u307e\u3059\u3002<\/p>\n<p>\u3053\u306e\u3088\u3046\u306a\u554f\u984c\u306b\u5bfe\u3057\u3066\u30012015\u5e74\u306b\u7c73\u56fd\u306b\u304a\u3044\u3066\u767a\u8868\u3055\u308c\u305fPrecision Medicine initiative\uff08\u500b\u5225\u5316\u533b\u7642\u3001\u7cbe\u5bc6\u533b\u7642\uff09\u3068\u3044\u3046\u6982\u5ff5\u306f\u3001\u65e5\u672c\u6211\u304c\u56fd\u306e\u533b\u7642\u696d\u754c\u306e\u307f\u306a\u3089\u305a\u5168\u4e16\u754c\u898f\u6a21\u3067\u7740\u5b9f\u306b\u5b9a\u7740\u3057\u3064\u3064\u3042\u308a\u307e\u3059\u3002\u500b\u4eba\u306e\u907a\u4f1d\u5b50\u60c5\u5831\u3092\u89e3\u6790\u3057\u3001\u305d\u308c\u3089\u306e\u7279\u5fb4\u3092\u8e0f\u307e\u3048\u306a\u304c\u3089\u3001\u6700\u9069\u306a\u6cbb\u7642\u65b9\u91dd\u3092\u6c7a\u3081\u308b\u3068\u3044\u3046\u7cbe\u5bc6\u304b\u3064\u7121\u99c4\u306e\u306a\u3044\u533b\u7642\u306e\u5b9f\u73fe\u304c\u671f\u5f85\u3055\u308c\u3066\u3044\u307e\u3059\u3002\u6211\u304c\u56fd\u3067\u3082\u304c\u3093\u306b\u5bfe\u3059\u308b\u5927\u898f\u6a21\u306a\u81e8\u5e8a\u8a66\u9a13\u304c\u5b9f\u65bd\u3055\u308c\u3001\u304c\u3093\u3092\u542b\u3080\u3055\u307e\u3056\u307e\u306a\u75be\u60a3\u306b\u5bfe\u3059\u308b\u907a\u4f1d\u5b50\u691c\u67fb\u3092\u7528\u3044\u305f\u30b2\u30ce\u30e0\u533b\u7642\u306e\u57fa\u76e4\u6574\u5099\u304c\u9032\u3093\u3067\u3044\u307e\u3059\u3002<\/p>\n<p>\u305d\u3053\u3067\u4eca\u56de\u306f\u3001\u6628\u4eca\u8a71\u984c\u306b\u306a\u3063\u3066\u3044\u308b\u500b\u5225\u5316\u533b\u7642\u3068\u304c\u3093\u30b2\u30ce\u30e0\u7814\u7a76\u306b\u5fc5\u8981\u4e0d\u53ef\u6b20\u306a\u6b21\u4e16\u4ee3\u30b7\u30fc\u30b1\u30f3\u30b5\u306b\u3064\u3044\u3066\u3001\u3054\u7d39\u4ecb\u3044\u305f\u3057\u307e\u3059\u3002<\/p>\n<p>&nbsp;<\/p>\n<p>\u25bc\u3053\u3093\u306a\u65b9 \u306b\u304a\u3059\u3059\u3081\u3067\u3059\uff01<br \/>\n\u30fb\u304c\u3093\u30b2\u30ce\u30e0\u7814\u7a76\u3092\u884c\u3063\u3066\u3044\u308b\u65b9\u3001\u8208\u5473\u306e\u3042\u308b\u65b9<br \/>\n\u30fb\u6b21\u4e16\u4ee3\u30b7\u30fc\u30b1\u30f3\u30b5\u306b\u3088\u308b\u304c\u3093\u30b2\u30ce\u30e0\u89e3\u6790\u306b\u8208\u5473\u306e\u3042\u308b\u65b9<\/p>\n<h2>\u500b\u5225\u5316\u533b\u7642\u3068\u6b21\u4e16\u4ee3\u30b7\u30fc\u30b1\u30f3\u30b5<\/h2>\n<p>\u7c73\u56fd\u306b\u30661985\u5e74\u306b\u958b\u59cb\u3055\u308c\u305f\u30d2\u30c8\u30b2\u30ce\u30e0\u8a08\u753b\u306f\u30011991\u5e74\u306b\u6211\u304c\u56fd\u3067\u3082\u958b\u59cb\u3055\u308c\u30012003\u5e74\u306b\u5b8c\u4e86\u3057\u307e\u3057\u305f\u3002\u5f53\u6642\u306e\u6280\u8853\u306710\u5e74\u3092\u8d85\u3048\u308b\u6642\u9593\u3092\u304b\u3051\u3066\u89e3\u6790\u3057\u3066\u3044\u305f\u30d2\u30c8\u306e\u5168\u30b2\u30ce\u30e0\u914d\u5217\u306f\u3001\u30d2\u30c8\u30b2\u30ce\u30e0\u8a08\u753b\u5b8c\u4e86\u304b\u308916\u5e74\u7d4c\u3063\u305f\u73fe\u5728\u3001\u6b21\u4e16\u4ee3\u30b7\u30fc\u30b1\u30f3\u30b9\u3068\u547c\u3070\u308c\u308bDNA\u30b7\u30fc\u30b1\u30f3\u30b9\u6280\u8853\u306e\u5927\u5e45\u306a\u9032\u6b69\u306b\u3088\u3063\u3066\u30011\u9031\u9593\u7a0b\u5ea6\u3067\u89e3\u6790\u3067\u304d\u308b\u3088\u3046\u306b\u306a\u308a\u307e\u3057\u305f\u3002\u5358\u4e00\u306e\u907a\u4f1d\u5b50\u5909\u7570\u306a\u3069\u306e\u5834\u5408\u306b\u306f\u3001\u4ed6\u306e\u30d7\u30e9\u30c3\u30c8\u30d5\u30a9\u30fc\u30e0\u3067\u3082\u89e3\u6790\u53ef\u80fd\u3067\u3059\u304c\u3001\u591a\u69d8\u306a\u9818\u57df\u3001\u591a\u69d8\u306a\u691c\u4f53\u3092\u4e00\u5ea6\u306b\u89e3\u6790\u3059\u308b\u3068\u3044\u3046\u76ee\u7684\u306b\u304a\u3044\u3066\u3001\u6b21\u4e16\u4ee3\u30b7\u30fc\u30b1\u30f3\u30b5\u306f\u6700\u9069\u306a\u30d7\u30e9\u30c3\u30c8\u30d5\u30a9\u30fc\u30e0\u3068\u306a\u3063\u3066\u3044\u307e\u3059\u3002\u3053\u306e\u3088\u3046\u306b\u500b\u4eba\u306e\u30b2\u30ce\u30e0\u3092\u89e3\u6790\u3059\u308b\u3053\u3068\u304c\u53ef\u80fd\u306b\u306a\u3063\u305f\u73fe\u5728\u3001\u3053\u306e\u6b21\u4e16\u4ee3\u30b7\u30fc\u30b1\u30f3\u30b9\u3092\u7528\u3044\u3066\u3001\u500b\u4eba\u306e\u907a\u4f1d\u7684\u306a\u7279\u5fb4\u3092\u7406\u89e3\u3057\u3001\u305d\u308c\u305e\u308c\u306b\u9069\u3057\u305f\u85ac\u306e\u9069\u7528\u3084\u6cbb\u7642\u65b9\u91dd\u306e\u6c7a\u5b9a\u304c\u6c42\u3081\u3089\u308c\u308b\u793e\u4f1a\u3068\u306a\u3063\u3066\u3044\u307e\u3059\u3002<\/p>\n<p>\u30b2\u30ce\u30e0\u5168\u4f53\u3092\u89e3\u6790\u3059\u308b\u3053\u3068\u306f\u3055\u307e\u3056\u307e\u306a\u30ea\u30b9\u30af\u3092\u4e88\u6e2c\u3059\u308b\u3001\u3042\u308b\u3044\u306f\u75be\u60a3\u3092\u7406\u89e3\u3059\u308b\u3046\u3048\u3067\u3001\u975e\u5e38\u306b\u91cd\u8981\u3067\u3059\u3002\u3057\u304b\u3057\u3001\u5168\u30b2\u30ce\u30e0\u89e3\u6790\u306b\u306f\u672a\u3060\u591a\u304f\u306e\u8cbb\u7528\u3084\u6642\u9593\u304c\u4f34\u3046\u305f\u3081\u3001\u7570\u306a\u308b\u30a2\u30d7\u30ed\u30fc\u30c1\u306b\u3088\u308b\u30b2\u30ce\u30e0\u89e3\u6790\u304c\u6a21\u7d22\u3055\u308c\u3066\u3044\u307e\u3057\u305f\u3002\u305d\u3053\u3067\u3001\u6b21\u306b\u898b\u51fa\u3055\u308c\u305f\u6280\u8853\u304c\u30bf\u30fc\u30b2\u30c3\u30c8\u30ea\u30b7\u30fc\u30b1\u30f3\u30b9\u3068\u3044\u3046\u624b\u6cd5\u3067\u3059\u3002<\/p>\n<p><img decoding=\"async\" style=\"margin-left: auto;margin-right: auto\" src=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/11\/genomic20medicine-19.jpg\" \/><\/p>\n<p>\u304c\u3093\u3084\u907a\u4f1d\u6027\u75be\u60a3\u306a\u3069\u306b\u95a2\u3057\u3066\u3001\u3042\u3089\u304b\u3058\u3081\u305d\u306e\u75c5\u614b\u306b\u95a2\u9023\u3057\u3066\u3044\u308b\u3053\u3068\u304c\u5831\u544a\u3055\u308c\u3066\u3044\u308b\u907a\u4f1d\u5b50\uff08\u6570\u5341\uff5e\u6570\u767e\u907a\u4f1d\u5b50\uff09\u306b\u9650\u5b9a\u3057\u3066\u89e3\u6790\u3059\u308b\u3053\u3068\u306b\u3088\u308a\u3001\u3088\u308a\u77ed\u6642\u9593\u304b\u3064\u4f4e\u30b3\u30b9\u30c8\u3092\u5b9f\u73fe\u3057\u3001\u816b\u760d\u7d44\u7e54\u306e\u4e0d\u5747\u4e00\u6027\u304b\u3089\u751f\u3058\u308b\u4f4e\u983b\u5ea6\u5909\u7570\u3082\u691c\u51fa\u53ef\u80fd\u3068\u306a\u308a\u307e\u3057\u305f\u3002<\/p>\n<p>\u3053\u306e\u3088\u3046\u306b\u6b21\u4e16\u4ee3\u30b7\u30fc\u30b1\u30f3\u30b5\u306f\u3001<br \/>\n\u30fb\u500b\u4eba\u306e\u7279\u5fb4\u3092\u591a\u69d8\u306a\u907a\u4f1d\u5b50\u9818\u57df\u3067\u3068\u3089\u3048\u308b<br \/>\n\u30fb\u75be\u60a3\u306e\u7279\u5fb4\u3092\u591a\u69d8\u306a\u907a\u4f1d\u5b50\u9818\u57df\u3067\u3068\u3089\u3048\u308b<br \/>\n\u3068\u3044\u3063\u305f\u76ee\u7684\u306b\u6700\u9069\u306a\u6a5f\u5668\u3067\u3059\u3002<\/p>\n<p>\u65e5\u672c\u3067\u3082\u3001\u304c\u3093\u306e\u30b2\u30ce\u30e0\u60c5\u5831\u306b\u57fa\u3065\u3044\u305f\u6cbb\u7642\u3092\u884c\u3046\u3079\u304f\u3001\u304c\u3093\u30b2\u30ce\u30e0\u533b\u7642\u3092\u727d\u5f15\u3059\u308b\u304c\u3093\u30b2\u30ce\u30e0\u533b\u7642\u4e2d\u6838\u62e0\u70b9\u75c5\u9662\u3092\u4e2d\u5fc3\u3068\u3057\u305f\u533b\u7642\u4f53\u5236\u3092\u6574\u5099\u3059\u308b\u3053\u3068\u3067\u3001\u5168\u56fd\u3069\u3053\u306b\u3044\u3066\u3082\u304c\u3093\u30b2\u30ce\u30e0\u533b\u7642\u304c\u53d7\u3051\u3089\u308c\u308b\u4f53\u5236\u304c\u6bb5\u968e\u7684\u306b\u69cb\u7bc9\u3055\u308c\u3064\u3064\u3042\u308a\u307e\u3059\u3002<\/p>\n<p>\u3053\u306e\u3088\u3046\u306a\u533b\u7642\u4f53\u5236\u306e\u3082\u3068\u3001\u65e2\u306b\u6b21\u4e16\u4ee3\u30b7\u30fc\u30b1\u30f3\u30b5\u3092\u7528\u3044\u305f\u4fdd\u967a\u8a3a\u7642\u304c\u59cb\u307e\u3063\u3066\u3044\u307e\u3059\u3002\u4f8b\u3048\u3070\u3001\u907a\u4f1d\u5b50\u30d1\u30cd\u30eb\u691c\u67fb\u3067\u306f\u3001\u75c5\u9662\u3084\u691c\u67fb\u4f1a\u793e\u306a\u3069\u3055\u307e\u3056\u307e\u306a\u7d44\u7e54\u30fb\u65bd\u8a2d\u304c\u5354\u50cd\u3057\u3066\u3001\u691c\u4f53\u304b\u3089\u306e\u6838\u9178\u62bd\u51fa\u3084\u6b21\u4e16\u4ee3\u30b7\u30fc\u30b1\u30f3\u30b9\u306e\u5b9f\u65bd\u3001\u30c7\u30fc\u30bf\u89e3\u6790\u3001\u5f97\u3089\u308c\u305f\u30c7\u30fc\u30bf\u306b\u57fa\u3065\u3044\u305f\u5c02\u9580\u30c1\u30fc\u30e0\uff08\u30a8\u30ad\u30b9\u30d1\u30fc\u30c8\u30d1\u30cd\u30eb\uff09\u306b\u3088\u308b\u4f1a\u8b70\u306a\u3069\u3001\u500b\u4eba\u3084\u304c\u3093\u306e\u30b2\u30ce\u30e0\u306e\u7279\u5fb4\u3092\u6349\u3048\u305f\u7cbe\u5bc6\u306a\u533b\u7642\u304c\u9032\u3081\u3089\u308c\u3066\u3044\u307e\u3059\u3002<\/p>\n<p><img decoding=\"async\" style=\"margin-left: auto;margin-right: auto\" src=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/11\/clinical20sequence-19.jpg\" \/><\/p>\n<h2>\u304c\u3093\u30b2\u30ce\u30e0\u7814\u7a76\u3068\u6b21\u4e16\u4ee3\u30b7\u30fc\u30b1\u30f3\u30b5<\/h2>\n<p>\u524d\u8ff0\u306e\u3088\u3046\u306aDNA\u30b7\u30fc\u30b1\u30f3\u30b9\u306e\u9769\u65b0\u7684\u306a\u6280\u8853\u9032\u6b69\u306b\u3088\u308a\u3001\u304c\u3093\u306b\u95a2\u9023\u3059\u308b\u5206\u5b50\u6a19\u7684\u6cbb\u7642\u85ac\u306e\u81e8\u5e8a\u8a66\u9a13\u3084\u65b0\u305f\u306a\u85ac\u306e\u958b\u767a\u306e\u305f\u3081\u306e\u30d0\u30a4\u30aa\u30de\u30fc\u30ab\u30fc\u306e\u7814\u7a76\u304c\u6d3b\u767a\u306b\u884c\u308f\u308c\u3066\u3044\u307e\u3059\u3002<\/p>\n<p>\u6b21\u4e16\u4ee3\u30b7\u30fc\u30b1\u30f3\u30b5\u306f\u3001\u30b5\u30f3\u30d7\u30eb\u306b\u542b\u307e\u308c\u308b\u6838\u9178\u306e\u5869\u57fa\u914d\u5217\u3092\u77ed\u6642\u9593\u3067\u5927\u91cf\u306b\u89e3\u6790\u3059\u308b\u3053\u3068\u304c\u3067\u304d\u308b\u6a5f\u5668\u3067\u3059\u3002\u3053\u306e\u6a5f\u5668\u3092\u7528\u3044\u3066\u3001\u3055\u307e\u3056\u307e\u306a\u7d44\u7e54\u306e\u56fa\u5f62\u816b\u760d\u3092\u59cb\u3081\u3001\u9020\u8840\u5668\u816b\u760d\uff08\u767d\u8840\u75c5\u306a\u3069\uff09\u306b\u542b\u307e\u308c\u308b\u304c\u3093\u95a2\u9023\u907a\u4f1d\u5b50\u306e\u4e00\u5869\u57fa\u5909\u7570\u3001\u633f\u5165\u30fb\u6b20\u5931\u3001\u30b3\u30d4\u30fc\u30ca\u30f3\u30d0\u30fc\u306e\u30d0\u30ea\u30a8\u30fc\u30b7\u30e7\u30f3\u3001\u878d\u5408\u907a\u4f1d\u5b50\u306a\u3069\u3092\u89e3\u6790\u3059\u308b\u3053\u3068\u306b\u3088\u308a\u3001\u816b\u760d\u5f62\u6210\u3084\u6d78\u6f64\u3001\u8ee2\u79fb\u306a\u3069\u3001\u304c\u3093\u306e\u9032\u884c\u306b\u95a2\u9023\u3059\u308b\u7279\u5b9a\u306e\u5909\u7570\u306e\u540c\u5b9a\u304a\u3088\u3073\u6a5f\u80fd\u7684\u5206\u985e\u306a\u3069\u306b\u5fc5\u8981\u306a\u60c5\u5831\u3092\u5f97\u308b\u3053\u3068\u304c\u53ef\u80fd\u3067\u3059\u3002<\/p>\n<p>\u307e\u305f\u3001\u816b\u760d\u7d44\u7e54\u305d\u306e\u3082\u306e\u3092\u89e3\u6790\u3059\u308b\u3060\u3051\u3067\u306a\u304f\u3001\u8fd1\u5e74\u8a71\u984c\u3068\u306a\u3063\u3066\u3044\u308b\u304c\u3093\u306b\u95a2\u9023\u3059\u308b\u514d\u75ab\u30b7\u30b9\u30c6\u30e0\u306e\u7406\u89e3\u306b\u3082\u6b21\u4e16\u4ee3\u30b7\u30fc\u30b1\u30f3\u30b5\u306f\u4e0d\u53ef\u6b20\u3067\u3059\u3002\u4f53\u7d30\u80de\u5909\u7570\u3092\u6709\u3059\u308b\u304c\u3093\u7d30\u80de\u306f\u3001\u30b2\u30ce\u30e0\u3042\u305f\u308a\u306e\u5909\u7570\u91cf\u304c\u591a\u3044\u307b\u3069\u3001\u5206\u5b50\u6a19\u7684\u6cbb\u7642\u85ac\u306e\u52b9\u679c\u304c\u9ad8\u3044\u3068\u3044\u3046\u5831\u544a\u304c\u3042\u308a\u3001\u4f53\u7d30\u80de\u5909\u7570\u91cf\u3092\u6b21\u4e16\u4ee3\u30b7\u30fc\u30b1\u30f3\u30b5\u3067\u89e3\u6790\u3059\u308b\u3068\u3044\u3046\u8a66\u307f\u304c\u76db\u3093\u306b\u884c\u308f\u308c\u3066\u3044\u307e\u3059\u3002\u307e\u305f\u3001\u8840\u6db2\u3084\u30ea\u30f3\u30d1\u7d44\u7e54\u306b\u5b58\u5728\u3059\u308b\u514d\u75ab\u7cfb\u7d30\u80de\uff08T\u7d30\u80de\u306a\u3069\uff09\u306e\u96c6\u56e3\u3092\u89e3\u6790\u3059\u308b\u3053\u3068\u306b\u3088\u308a\u3001\u304c\u3093\u306b\u5bfe\u3057\u3066\u6a5f\u80fd\u3057\u3066\u3044\u308b\u514d\u75ab\u7d30\u80de\u306e\u7a2e\u985e\u3092\u540c\u5b9a\u3057\u3001\u52b9\u679c\u7684\u306aT\u7d30\u80de\u96c6\u56e3\u306e\u307f\u3092\u5897\u6b96\u3055\u305b\u3001\u304c\u3093\u3092\u653b\u6483\u3055\u305b\u308b\u3068\u3044\u3063\u305f\u624b\u6cd5\u3082\u958b\u767a\u3055\u308c\u3066\u3044\u307e\u3059\u3002\u3055\u3089\u306b\u3001\u816b\u760d\u5468\u8fba\u306e\u7d44\u7e54\u306e\u907a\u4f1d\u5b50\u767a\u73fe\u89e3\u6790\u3092\u884c\u3046\u3053\u3068\u306b\u3088\u308a\u3001\u816b\u760d\u3068\u514d\u75ab\u30b7\u30b9\u30c6\u30e0\u306e\u62ee\u6297\u7684\u95a2\u4fc2\u3092\u660e\u3089\u304b\u306b\u3059\u308b\u3068\u3044\u3063\u305f\u7814\u7a76\u3082\u76db\u3093\u306b\u884c\u308f\u308c\u3066\u3044\u307e\u3059\u3002<\/p>\n<p>\u3055\u3089\u306b\u3001\u304c\u3093\u306e\u6cbb\u7642\u5f8c\u306b\u3082\u8840\u6db2\u306a\u3069\u306e\u6db2\u6027\u691c\u4f53\uff08\u30ea\u30ad\u30c3\u30c9\u30d0\u30a4\u30aa\u30d7\u30b7\u30fc\uff09\u3092\u7d99\u7d9a\u7684\u306b\u30b5\u30f3\u30d7\u30ea\u30f3\u30b0\u3057\u3001\u305d\u3053\u306b\u542b\u307e\u308c\u308b\u304c\u3093\u306e\u75d5\u8de1\u3092\u89e3\u6790\u3059\u308b\u3053\u3068\u306b\u3088\u308a\u3001\u518d\u767a\u306a\u3069\u3092\u65e9\u671f\u306b\u767a\u898b\u3067\u304d\u308b\u53ef\u80fd\u6027\u3082\u793a\u5506\u3055\u308c\u3066\u3044\u307e\u3059\u3002<\/p>\n<p><a href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/global\/forms\/ngs-oncomine-video.html?CID=Social_LAB\" target=\"_blank\" rel=\"noopener noreferrer\"><img decoding=\"async\" src=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/11\/3video-16.jpg\" \/><\/a><\/p>\n<p><a href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/global\/forms\/ngs-oncomine-video.html?CID=csd_cdx_sbu_r04_jp_cp0000_pjt0000_gsd00000_0so_blg_op_awa_oc_s00_ngs2_Social_LAB\" target=\"_blank\" rel=\"noopener noreferrer\">\u52d5\u753b\u3078\u306e\u30ea\u30f3\u30af\u306f\u3053\u3061\u3089<\/a><\/p>\n<p>\u25bc\u3053\u3061\u3089\u306e\u8a18\u4e8b\u3082\u304a\u3059\u3059\u3081\u3067\u3059\uff01<br \/>\n<a href=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/liquidbiopsy\/?CID=csd_cdx_sbu_r04_jp_cp0000_pjt0000_gsd00000_0so_blg_op_awa_oc_s00_ngs2_Social_LAB\" target=\"_blank\" rel=\"noopener noreferrer\">5\u5206\u3067\u308f\u304b\u308b\uff01\u304c\u3093\u306e\u8d85\u65e9\u671f\u767a\u898b\u306b\u5f79\u7acb\u3064\u30ea\u30ad\u30c3\u30c9\u30d0\u30a4\u30aa\u30d7\u30b7\u30fc<\/a><\/p>\n<p>\u7814\u7a76\u7528\u306b\u306e\u307f\u4f7f\u7528\u3067\u304d\u307e\u3059\u3002\u8a3a\u65ad\u76ee\u7684\u304a\u3088\u3073\u305d\u306e\u624b\u7d9a\u304d\u4e0a\u3067\u306e\u4f7f\u7528\u306f\u3067\u304d\u307e\u305b\u3093\u3002<\/p>\n","protected":false},"excerpt":{"rendered":"<p>\u8fd1\u5e74\u3001\u304c\u3093\u306a\u3069\u306e\u75be\u60a3\u306b\u5bfe\u3059\u308b\u5206\u5b50\u6a19\u7684\u6cbb\u7642\u85ac\u306e\u958b\u767a\u306f\u3081\u3056\u307e\u3057\u304f\u3001\u591a\u304f\u306e\u60a3\u8005\u306b\u3068\u3063\u3066\u5e0c\u671b\u306e\u5149\u3068\u306a\u3063\u3066\u3044\u307e\u3059\u3002\u305d\u306e\u4e00\u65b9\u3067\u3001\u5b9f\u969b\u306b\u85ac\u5264\u3092\u9069\u7528\u3067\u304d\u308b\u60a3\u8005\u3084\u3001\u85ac\u5264\u306e\u52b9\u679c\u304c\u898b\u3089\u308c\u308b\u60a3\u8005\u306f\u4e00\u90e8\u306b\u9650\u3089\u308c\u308b\u3053\u3068\u304c\u308f\u304b\u3063\u3066\u304d\u307e\u3057\u305f\u3002\u307e\u305f\u3001\u5e0c\u5c11<\/p>\n","protected":false},"author":988,"featured_media":5847,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_monsterinsights_skip_tracking":false,"_monsterinsights_sitenote_active":false,"_monsterinsights_sitenote_note":"","_monsterinsights_sitenote_category":0,"_genesis_hide_title":false,"_genesis_hide_breadcrumbs":false,"_genesis_hide_singular_image":false,"_genesis_hide_footer_widgets":false,"_genesis_custom_body_class":"","_genesis_custom_post_class":"","_genesis_layout":"","_jetpack_newsletter_access":"","_jetpack_dont_email_post_to_subs":false,"_jetpack_newsletter_tier_id":0,"_jetpack_memberships_contains_paywalled_content":false,"_jetpack_feature_clip_id":0,"_jetpack_memberships_contains_paid_content":false,"footnotes":"","jetpack_post_was_ever_published":false},"categories":[156],"tags":[165],"division":[],"class_list":{"0":"post-5753","1":"post","2":"type-post","3":"status-publish","4":"format-standard","5":"has-post-thumbnail","7":"category-mol-bio","8":"tag-ngs","9":"entry"},"_selected_authors":"","_selected_reviewers":"","acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v27.8 (Yoast SEO v27.8) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>\u6b21\u4e16\u4ee3\u30b7\u30fc\u30b1\u30f3\u30b5\u3000\uff5e\u500b\u5225\u5316\u533b\u7642\u3068\u304c\u3093\u30b2\u30ce\u30e0\u7814\u7a76\uff5e<\/title>\n<meta name=\"description\" content=\"\u8fd1\u5e74\u3001\u304c\u3093\u306a\u3069\u306e\u75be\u60a3\u306b\u5bfe\u3059\u308b\u5206\u5b50\u6a19\u7684\u6cbb\u7642\u85ac\u306e\u958b\u767a\u306f\u3081\u3056\u307e\u3057\u304f\u3001\u591a\u304f\u306e\u60a3\u8005\u306b\u3068\u3063\u3066\u5e0c\u671b\u306e\u5149\u3068\u306a\u3063\u3066\u3044\u307e\u3059\u3002\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/\u6b21\u4e16\u4ee3\u30b7\u30fc\u30b1\u30f3\u30b5\uff5e\u500b\u5225\u5316\u533b\u7642\u3068\u304c\u3093\u30b2\u30ce\u30e0\u7814\/\" \/>\n<meta property=\"og:locale\" content=\"ja_JP\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"\u6b21\u4e16\u4ee3\u30b7\u30fc\u30b1\u30f3\u30b5\u3000\uff5e\u500b\u5225\u5316\u533b\u7642\u3068\u304c\u3093\u30b2\u30ce\u30e0\u7814\u7a76\uff5e\" \/>\n<meta property=\"og:description\" content=\"\u8fd1\u5e74\u3001\u304c\u3093\u306a\u3069\u306e\u75be\u60a3\u306b\u5bfe\u3059\u308b\u5206\u5b50\u6a19\u7684\u6cbb\u7642\u85ac\u306e\u958b\u767a\u306f\u3081\u3056\u307e\u3057\u304f\u3001\u591a\u304f\u306e\u60a3\u8005\u306b\u3068\u3063\u3066\u5e0c\u671b\u306e\u5149\u3068\u306a\u3063\u3066\u3044\u307e\u3059\u3002\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/\u6b21\u4e16\u4ee3\u30b7\u30fc\u30b1\u30f3\u30b5\uff5e\u500b\u5225\u5316\u533b\u7642\u3068\u304c\u3093\u30b2\u30ce\u30e0\u7814\/\" \/>\n<meta property=\"og:site_name\" content=\"Learning at the Bench\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/ThermoFisherJapan\" \/>\n<meta property=\"article:published_time\" content=\"2019-11-11T07:16:18+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2023-12-28T01:21:06+00:00\" \/>\n<meta property=\"og:image\" content=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/11\/3videobg.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"400\" \/>\n\t<meta property=\"og:image:height\" content=\"140\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"LATB Staff\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:creator\" content=\"@ThermoFisherJP\" \/>\n<meta name=\"twitter:site\" content=\"@ThermoFisherJP\" \/>\n<meta name=\"twitter:label1\" content=\"\u57f7\u7b46\u8005\" \/>\n\t<meta name=\"twitter:data1\" content=\"LATB Staff\" \/>\n\t<meta name=\"twitter:label2\" content=\"\u63a8\u5b9a\u8aad\u307f\u53d6\u308a\u6642\u9593\" \/>\n\t<meta name=\"twitter:data2\" content=\"7\u5206\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/%e6%ac%a1%e4%b8%96%e4%bb%a3%e3%82%b7%e3%83%bc%e3%82%b1%e3%83%b3%e3%82%b5%ef%bd%9e%e5%80%8b%e5%88%a5%e5%8c%96%e5%8c%bb%e7%99%82%e3%81%a8%e3%81%8c%e3%82%93%e3%82%b2%e3%83%8e%e3%83%a0%e7%a0%94\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/%e6%ac%a1%e4%b8%96%e4%bb%a3%e3%82%b7%e3%83%bc%e3%82%b1%e3%83%b3%e3%82%b5%ef%bd%9e%e5%80%8b%e5%88%a5%e5%8c%96%e5%8c%bb%e7%99%82%e3%81%a8%e3%81%8c%e3%82%93%e3%82%b2%e3%83%8e%e3%83%a0%e7%a0%94\\\/\"},\"author\":{\"name\":\"LATB Staff\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#\\\/schema\\\/person\\\/00a095a01d54afcdf9457465feb04f7d\"},\"headline\":\"\u6b21\u4e16\u4ee3\u30b7\u30fc\u30b1\u30f3\u30b5\u3000\uff5e\u500b\u5225\u5316\u533b\u7642\u3068\u304c\u3093\u30b2\u30ce\u30e0\u7814\u7a76\uff5e\",\"datePublished\":\"2019-11-11T07:16:18+00:00\",\"dateModified\":\"2023-12-28T01:21:06+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/%e6%ac%a1%e4%b8%96%e4%bb%a3%e3%82%b7%e3%83%bc%e3%82%b1%e3%83%b3%e3%82%b5%ef%bd%9e%e5%80%8b%e5%88%a5%e5%8c%96%e5%8c%bb%e7%99%82%e3%81%a8%e3%81%8c%e3%82%93%e3%82%b2%e3%83%8e%e3%83%a0%e7%a0%94\\\/\"},\"wordCount\":8,\"commentCount\":0,\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/%e6%ac%a1%e4%b8%96%e4%bb%a3%e3%82%b7%e3%83%bc%e3%82%b1%e3%83%b3%e3%82%b5%ef%bd%9e%e5%80%8b%e5%88%a5%e5%8c%96%e5%8c%bb%e7%99%82%e3%81%a8%e3%81%8c%e3%82%93%e3%82%b2%e3%83%8e%e3%83%a0%e7%a0%94\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2019\\\/11\\\/3videobg.jpg\",\"keywords\":[\"\u6b21\u4e16\u4ee3\u30b7\u30fc\u30b1\u30f3\u30b5\"],\"articleSection\":[\"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023\"],\"inLanguage\":\"ja\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/%e6%ac%a1%e4%b8%96%e4%bb%a3%e3%82%b7%e3%83%bc%e3%82%b1%e3%83%b3%e3%82%b5%ef%bd%9e%e5%80%8b%e5%88%a5%e5%8c%96%e5%8c%bb%e7%99%82%e3%81%a8%e3%81%8c%e3%82%93%e3%82%b2%e3%83%8e%e3%83%a0%e7%a0%94\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/%e6%ac%a1%e4%b8%96%e4%bb%a3%e3%82%b7%e3%83%bc%e3%82%b1%e3%83%b3%e3%82%b5%ef%bd%9e%e5%80%8b%e5%88%a5%e5%8c%96%e5%8c%bb%e7%99%82%e3%81%a8%e3%81%8c%e3%82%93%e3%82%b2%e3%83%8e%e3%83%a0%e7%a0%94\\\/\",\"url\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/%e6%ac%a1%e4%b8%96%e4%bb%a3%e3%82%b7%e3%83%bc%e3%82%b1%e3%83%b3%e3%82%b5%ef%bd%9e%e5%80%8b%e5%88%a5%e5%8c%96%e5%8c%bb%e7%99%82%e3%81%a8%e3%81%8c%e3%82%93%e3%82%b2%e3%83%8e%e3%83%a0%e7%a0%94\\\/\",\"name\":\"\u6b21\u4e16\u4ee3\u30b7\u30fc\u30b1\u30f3\u30b5\u3000\uff5e\u500b\u5225\u5316\u533b\u7642\u3068\u304c\u3093\u30b2\u30ce\u30e0\u7814\u7a76\uff5e\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/%e6%ac%a1%e4%b8%96%e4%bb%a3%e3%82%b7%e3%83%bc%e3%82%b1%e3%83%b3%e3%82%b5%ef%bd%9e%e5%80%8b%e5%88%a5%e5%8c%96%e5%8c%bb%e7%99%82%e3%81%a8%e3%81%8c%e3%82%93%e3%82%b2%e3%83%8e%e3%83%a0%e7%a0%94\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/%e6%ac%a1%e4%b8%96%e4%bb%a3%e3%82%b7%e3%83%bc%e3%82%b1%e3%83%b3%e3%82%b5%ef%bd%9e%e5%80%8b%e5%88%a5%e5%8c%96%e5%8c%bb%e7%99%82%e3%81%a8%e3%81%8c%e3%82%93%e3%82%b2%e3%83%8e%e3%83%a0%e7%a0%94\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2019\\\/11\\\/3videobg.jpg\",\"datePublished\":\"2019-11-11T07:16:18+00:00\",\"dateModified\":\"2023-12-28T01:21:06+00:00\",\"author\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#\\\/schema\\\/person\\\/00a095a01d54afcdf9457465feb04f7d\"},\"description\":\"\u8fd1\u5e74\u3001\u304c\u3093\u306a\u3069\u306e\u75be\u60a3\u306b\u5bfe\u3059\u308b\u5206\u5b50\u6a19\u7684\u6cbb\u7642\u85ac\u306e\u958b\u767a\u306f\u3081\u3056\u307e\u3057\u304f\u3001\u591a\u304f\u306e\u60a3\u8005\u306b\u3068\u3063\u3066\u5e0c\u671b\u306e\u5149\u3068\u306a\u3063\u3066\u3044\u307e\u3059\u3002\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/%e6%ac%a1%e4%b8%96%e4%bb%a3%e3%82%b7%e3%83%bc%e3%82%b1%e3%83%b3%e3%82%b5%ef%bd%9e%e5%80%8b%e5%88%a5%e5%8c%96%e5%8c%bb%e7%99%82%e3%81%a8%e3%81%8c%e3%82%93%e3%82%b2%e3%83%8e%e3%83%a0%e7%a0%94\\\/#breadcrumb\"},\"inLanguage\":\"ja\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/%e6%ac%a1%e4%b8%96%e4%bb%a3%e3%82%b7%e3%83%bc%e3%82%b1%e3%83%b3%e3%82%b5%ef%bd%9e%e5%80%8b%e5%88%a5%e5%8c%96%e5%8c%bb%e7%99%82%e3%81%a8%e3%81%8c%e3%82%93%e3%82%b2%e3%83%8e%e3%83%a0%e7%a0%94\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"ja\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/%e6%ac%a1%e4%b8%96%e4%bb%a3%e3%82%b7%e3%83%bc%e3%82%b1%e3%83%b3%e3%82%b5%ef%bd%9e%e5%80%8b%e5%88%a5%e5%8c%96%e5%8c%bb%e7%99%82%e3%81%a8%e3%81%8c%e3%82%93%e3%82%b2%e3%83%8e%e3%83%a0%e7%a0%94\\\/#primaryimage\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2019\\\/11\\\/3videobg.jpg\",\"contentUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2019\\\/11\\\/3videobg.jpg\",\"width\":400,\"height\":140},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/%e6%ac%a1%e4%b8%96%e4%bb%a3%e3%82%b7%e3%83%bc%e3%82%b1%e3%83%b3%e3%82%b5%ef%bd%9e%e5%80%8b%e5%88%a5%e5%8c%96%e5%8c%bb%e7%99%82%e3%81%a8%e3%81%8c%e3%82%93%e3%82%b2%e3%83%8e%e3%83%a0%e7%a0%94\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"\u6b21\u4e16\u4ee3\u30b7\u30fc\u30b1\u30f3\u30b5\u3000\uff5e\u500b\u5225\u5316\u533b\u7642\u3068\u304c\u3093\u30b2\u30ce\u30e0\u7814\u7a76\uff5e\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#website\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/\",\"name\":\"Learning at the Bench\",\"description\":\"\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"ja\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#\\\/schema\\\/person\\\/00a095a01d54afcdf9457465feb04f7d\",\"name\":\"LATB Staff\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"ja\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/8803277856c8b753feb4217dff0f9953327452df1a615c3c88b2f9864efb2ddd?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/8803277856c8b753feb4217dff0f9953327452df1a615c3c88b2f9864efb2ddd?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/8803277856c8b753feb4217dff0f9953327452df1a615c3c88b2f9864efb2ddd?s=96&d=mm&r=g\",\"caption\":\"LATB Staff\"},\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/author\\\/latbstaff\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"\u6b21\u4e16\u4ee3\u30b7\u30fc\u30b1\u30f3\u30b5\u3000\uff5e\u500b\u5225\u5316\u533b\u7642\u3068\u304c\u3093\u30b2\u30ce\u30e0\u7814\u7a76\uff5e","description":"\u8fd1\u5e74\u3001\u304c\u3093\u306a\u3069\u306e\u75be\u60a3\u306b\u5bfe\u3059\u308b\u5206\u5b50\u6a19\u7684\u6cbb\u7642\u85ac\u306e\u958b\u767a\u306f\u3081\u3056\u307e\u3057\u304f\u3001\u591a\u304f\u306e\u60a3\u8005\u306b\u3068\u3063\u3066\u5e0c\u671b\u306e\u5149\u3068\u306a\u3063\u3066\u3044\u307e\u3059\u3002","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/\u6b21\u4e16\u4ee3\u30b7\u30fc\u30b1\u30f3\u30b5\uff5e\u500b\u5225\u5316\u533b\u7642\u3068\u304c\u3093\u30b2\u30ce\u30e0\u7814\/","og_locale":"ja_JP","og_type":"article","og_title":"\u6b21\u4e16\u4ee3\u30b7\u30fc\u30b1\u30f3\u30b5\u3000\uff5e\u500b\u5225\u5316\u533b\u7642\u3068\u304c\u3093\u30b2\u30ce\u30e0\u7814\u7a76\uff5e","og_description":"\u8fd1\u5e74\u3001\u304c\u3093\u306a\u3069\u306e\u75be\u60a3\u306b\u5bfe\u3059\u308b\u5206\u5b50\u6a19\u7684\u6cbb\u7642\u85ac\u306e\u958b\u767a\u306f\u3081\u3056\u307e\u3057\u304f\u3001\u591a\u304f\u306e\u60a3\u8005\u306b\u3068\u3063\u3066\u5e0c\u671b\u306e\u5149\u3068\u306a\u3063\u3066\u3044\u307e\u3059\u3002","og_url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/\u6b21\u4e16\u4ee3\u30b7\u30fc\u30b1\u30f3\u30b5\uff5e\u500b\u5225\u5316\u533b\u7642\u3068\u304c\u3093\u30b2\u30ce\u30e0\u7814\/","og_site_name":"Learning at the Bench","article_publisher":"https:\/\/www.facebook.com\/ThermoFisherJapan","article_published_time":"2019-11-11T07:16:18+00:00","article_modified_time":"2023-12-28T01:21:06+00:00","og_image":[{"width":400,"height":140,"url":"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/11\/3videobg.jpg","type":"image\/jpeg"}],"author":"LATB Staff","twitter_card":"summary_large_image","twitter_creator":"@ThermoFisherJP","twitter_site":"@ThermoFisherJP","twitter_misc":{"\u57f7\u7b46\u8005":"LATB Staff","\u63a8\u5b9a\u8aad\u307f\u53d6\u308a\u6642\u9593":"7\u5206"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/%e6%ac%a1%e4%b8%96%e4%bb%a3%e3%82%b7%e3%83%bc%e3%82%b1%e3%83%b3%e3%82%b5%ef%bd%9e%e5%80%8b%e5%88%a5%e5%8c%96%e5%8c%bb%e7%99%82%e3%81%a8%e3%81%8c%e3%82%93%e3%82%b2%e3%83%8e%e3%83%a0%e7%a0%94\/#article","isPartOf":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/%e6%ac%a1%e4%b8%96%e4%bb%a3%e3%82%b7%e3%83%bc%e3%82%b1%e3%83%b3%e3%82%b5%ef%bd%9e%e5%80%8b%e5%88%a5%e5%8c%96%e5%8c%bb%e7%99%82%e3%81%a8%e3%81%8c%e3%82%93%e3%82%b2%e3%83%8e%e3%83%a0%e7%a0%94\/"},"author":{"name":"LATB Staff","@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#\/schema\/person\/00a095a01d54afcdf9457465feb04f7d"},"headline":"\u6b21\u4e16\u4ee3\u30b7\u30fc\u30b1\u30f3\u30b5\u3000\uff5e\u500b\u5225\u5316\u533b\u7642\u3068\u304c\u3093\u30b2\u30ce\u30e0\u7814\u7a76\uff5e","datePublished":"2019-11-11T07:16:18+00:00","dateModified":"2023-12-28T01:21:06+00:00","mainEntityOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/%e6%ac%a1%e4%b8%96%e4%bb%a3%e3%82%b7%e3%83%bc%e3%82%b1%e3%83%b3%e3%82%b5%ef%bd%9e%e5%80%8b%e5%88%a5%e5%8c%96%e5%8c%bb%e7%99%82%e3%81%a8%e3%81%8c%e3%82%93%e3%82%b2%e3%83%8e%e3%83%a0%e7%a0%94\/"},"wordCount":8,"commentCount":0,"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/%e6%ac%a1%e4%b8%96%e4%bb%a3%e3%82%b7%e3%83%bc%e3%82%b1%e3%83%b3%e3%82%b5%ef%bd%9e%e5%80%8b%e5%88%a5%e5%8c%96%e5%8c%bb%e7%99%82%e3%81%a8%e3%81%8c%e3%82%93%e3%82%b2%e3%83%8e%e3%83%a0%e7%a0%94\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/11\/3videobg.jpg","keywords":["\u6b21\u4e16\u4ee3\u30b7\u30fc\u30b1\u30f3\u30b5"],"articleSection":["\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023"],"inLanguage":"ja","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/%e6%ac%a1%e4%b8%96%e4%bb%a3%e3%82%b7%e3%83%bc%e3%82%b1%e3%83%b3%e3%82%b5%ef%bd%9e%e5%80%8b%e5%88%a5%e5%8c%96%e5%8c%bb%e7%99%82%e3%81%a8%e3%81%8c%e3%82%93%e3%82%b2%e3%83%8e%e3%83%a0%e7%a0%94\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/%e6%ac%a1%e4%b8%96%e4%bb%a3%e3%82%b7%e3%83%bc%e3%82%b1%e3%83%b3%e3%82%b5%ef%bd%9e%e5%80%8b%e5%88%a5%e5%8c%96%e5%8c%bb%e7%99%82%e3%81%a8%e3%81%8c%e3%82%93%e3%82%b2%e3%83%8e%e3%83%a0%e7%a0%94\/","url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/%e6%ac%a1%e4%b8%96%e4%bb%a3%e3%82%b7%e3%83%bc%e3%82%b1%e3%83%b3%e3%82%b5%ef%bd%9e%e5%80%8b%e5%88%a5%e5%8c%96%e5%8c%bb%e7%99%82%e3%81%a8%e3%81%8c%e3%82%93%e3%82%b2%e3%83%8e%e3%83%a0%e7%a0%94\/","name":"\u6b21\u4e16\u4ee3\u30b7\u30fc\u30b1\u30f3\u30b5\u3000\uff5e\u500b\u5225\u5316\u533b\u7642\u3068\u304c\u3093\u30b2\u30ce\u30e0\u7814\u7a76\uff5e","isPartOf":{"@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/%e6%ac%a1%e4%b8%96%e4%bb%a3%e3%82%b7%e3%83%bc%e3%82%b1%e3%83%b3%e3%82%b5%ef%bd%9e%e5%80%8b%e5%88%a5%e5%8c%96%e5%8c%bb%e7%99%82%e3%81%a8%e3%81%8c%e3%82%93%e3%82%b2%e3%83%8e%e3%83%a0%e7%a0%94\/#primaryimage"},"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/%e6%ac%a1%e4%b8%96%e4%bb%a3%e3%82%b7%e3%83%bc%e3%82%b1%e3%83%b3%e3%82%b5%ef%bd%9e%e5%80%8b%e5%88%a5%e5%8c%96%e5%8c%bb%e7%99%82%e3%81%a8%e3%81%8c%e3%82%93%e3%82%b2%e3%83%8e%e3%83%a0%e7%a0%94\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/11\/3videobg.jpg","datePublished":"2019-11-11T07:16:18+00:00","dateModified":"2023-12-28T01:21:06+00:00","author":{"@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#\/schema\/person\/00a095a01d54afcdf9457465feb04f7d"},"description":"\u8fd1\u5e74\u3001\u304c\u3093\u306a\u3069\u306e\u75be\u60a3\u306b\u5bfe\u3059\u308b\u5206\u5b50\u6a19\u7684\u6cbb\u7642\u85ac\u306e\u958b\u767a\u306f\u3081\u3056\u307e\u3057\u304f\u3001\u591a\u304f\u306e\u60a3\u8005\u306b\u3068\u3063\u3066\u5e0c\u671b\u306e\u5149\u3068\u306a\u3063\u3066\u3044\u307e\u3059\u3002","breadcrumb":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/%e6%ac%a1%e4%b8%96%e4%bb%a3%e3%82%b7%e3%83%bc%e3%82%b1%e3%83%b3%e3%82%b5%ef%bd%9e%e5%80%8b%e5%88%a5%e5%8c%96%e5%8c%bb%e7%99%82%e3%81%a8%e3%81%8c%e3%82%93%e3%82%b2%e3%83%8e%e3%83%a0%e7%a0%94\/#breadcrumb"},"inLanguage":"ja","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/%e6%ac%a1%e4%b8%96%e4%bb%a3%e3%82%b7%e3%83%bc%e3%82%b1%e3%83%b3%e3%82%b5%ef%bd%9e%e5%80%8b%e5%88%a5%e5%8c%96%e5%8c%bb%e7%99%82%e3%81%a8%e3%81%8c%e3%82%93%e3%82%b2%e3%83%8e%e3%83%a0%e7%a0%94\/"]}]},{"@type":"ImageObject","inLanguage":"ja","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/%e6%ac%a1%e4%b8%96%e4%bb%a3%e3%82%b7%e3%83%bc%e3%82%b1%e3%83%b3%e3%82%b5%ef%bd%9e%e5%80%8b%e5%88%a5%e5%8c%96%e5%8c%bb%e7%99%82%e3%81%a8%e3%81%8c%e3%82%93%e3%82%b2%e3%83%8e%e3%83%a0%e7%a0%94\/#primaryimage","url":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/11\/3videobg.jpg","contentUrl":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/11\/3videobg.jpg","width":400,"height":140},{"@type":"BreadcrumbList","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/%e6%ac%a1%e4%b8%96%e4%bb%a3%e3%82%b7%e3%83%bc%e3%82%b1%e3%83%b3%e3%82%b5%ef%bd%9e%e5%80%8b%e5%88%a5%e5%8c%96%e5%8c%bb%e7%99%82%e3%81%a8%e3%81%8c%e3%82%93%e3%82%b2%e3%83%8e%e3%83%a0%e7%a0%94\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/"},{"@type":"ListItem","position":2,"name":"\u6b21\u4e16\u4ee3\u30b7\u30fc\u30b1\u30f3\u30b5\u3000\uff5e\u500b\u5225\u5316\u533b\u7642\u3068\u304c\u3093\u30b2\u30ce\u30e0\u7814\u7a76\uff5e"}]},{"@type":"WebSite","@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#website","url":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/","name":"Learning at the Bench","description":"","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"ja"},{"@type":"Person","@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#\/schema\/person\/00a095a01d54afcdf9457465feb04f7d","name":"LATB Staff","image":{"@type":"ImageObject","inLanguage":"ja","@id":"https:\/\/secure.gravatar.com\/avatar\/8803277856c8b753feb4217dff0f9953327452df1a615c3c88b2f9864efb2ddd?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/8803277856c8b753feb4217dff0f9953327452df1a615c3c88b2f9864efb2ddd?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/8803277856c8b753feb4217dff0f9953327452df1a615c3c88b2f9864efb2ddd?s=96&d=mm&r=g","caption":"LATB Staff"},"url":"https:\/\/admin.acceleratingscience.com\/author\/latbstaff\/"}]}},"taxonomy_info":{"category":[{"value":156,"label":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023"}],"post_tag":[{"value":165,"label":"\u6b21\u4e16\u4ee3\u30b7\u30fc\u30b1\u30f3\u30b5"}]},"featured_image_src_large":["https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/11\/3videobg.jpg",400,140,false],"author_info":{"display_name":"LATB Staff","author_link":"https:\/\/admin.acceleratingscience.com\/author\/latbstaff\/"},"comment_info":0,"category_info":[{"term_id":156,"name":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","slug":"mol-bio","term_group":0,"term_taxonomy_id":156,"taxonomy":"category","description":"","parent":0,"count":531,"filter":"raw","meta":[],"cat_ID":156,"category_count":531,"category_description":"","cat_name":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","category_nicename":"mol-bio","category_parent":0}],"tag_info":[{"term_id":165,"name":"\u6b21\u4e16\u4ee3\u30b7\u30fc\u30b1\u30f3\u30b5","slug":"ngs","term_group":0,"term_taxonomy_id":165,"taxonomy":"post_tag","description":"","parent":0,"count":71,"filter":"raw","meta":[]}],"jetpack_featured_media_url":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/11\/3videobg.jpg","jetpack-related-posts":[{"id":23239,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/ngs-gene-expression-csd-ts-bfx-25060\/","url_meta":{"origin":5753,"position":0},"title":"\u98df\u54c1\u958b\u767a\u306b\u304a\u3051\u308b\u83cc\u53e2\u89e3\u6790\u3068\u907a\u4f1d\u5b50\u767a\u73fe\u89e3\u6790\u306e\u6d3b\u7528","author":"LatB Staff","date":"2025\u5e7410\u67088\u65e5","format":false,"excerpt":"\u907a\u4f1d\u5b50\u95a2\u9023\u306e\u89e3\u6790\u6280\u8853\u304c\u7814\u7a76\u306e\u307f\u306a\u3089\u305a\u7523\u696d\u5206\u91ce\u3067\u6d3b\u7528\u3055\u308c\u308b\u3088\u3046\u306b\u306a\u308a\u3001\u5e74\u6708\u304c\u7d4c\u904e\u3059\u308b\u306b\u3064\u308c\u3066\u5fdc\u7528\u7bc4\u56f2\u3082\u2026","rel":"","context":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","block_context":{"text":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/mol-bio\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/09\/ngs-gene-expression-gsd-ts-tr-25060_eyecatch.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/09\/ngs-gene-expression-gsd-ts-tr-25060_eyecatch.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/09\/ngs-gene-expression-gsd-ts-tr-25060_eyecatch.jpg?resize=525%2C300&ssl=1 1.5x"},"classes":[]},{"id":24187,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/ngs-gene-expression-csd-ts-ion-25073\/","url_meta":{"origin":5753,"position":1},"title":"\u3010\u3084\u3063\u3066\u307f\u305f\u3011\u5fae\u91cf\u30fb\u5206\u89e3RNA\u306b\u3088\u308b\u767a\u73fe\u89e3\u6790\u306e\u6700\u9069\u89e3\u306f\uff1fRNA-Seq\u3068Ion AmpliSeq Transcriptome\u3092\u6bd4\u3079\u3066\u307f\u305f","author":"LatB Staff","date":"2025\u5e7411\u670828\u65e5","format":false,"excerpt":"\u6b21\u4e16\u4ee3\u30b7\u30fc\u30b1\u30f3\u30b5\u3067\u306e\u767a\u73fe\u89e3\u6790\u306b\u53d6\u308a\u7d44\u3080\u969b\u3001RNA\u30b5\u30f3\u30d7\u30eb\u304c\u300c\u5c11\u306a\u3059\u304e\u308b\u300d\u300c\u5206\u89e3\u3057\u3066\u3044\u308b\u300d\u3068\u3044\u3046\u72b6\u6cc1\u306f\u2026","rel":"","context":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","block_context":{"text":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/mol-bio\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/11\/ngs-gene-expression-csd-ts-ion-25073_eyecatch-scaled.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/11\/ngs-gene-expression-csd-ts-ion-25073_eyecatch-scaled.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/11\/ngs-gene-expression-csd-ts-ion-25073_eyecatch-scaled.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/11\/ngs-gene-expression-csd-ts-ion-25073_eyecatch-scaled.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/11\/ngs-gene-expression-csd-ts-ion-25073_eyecatch-scaled.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/11\/ngs-gene-expression-csd-ts-ion-25073_eyecatch-scaled.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":20124,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/exosome-gene-therapy-ts-r-25015\/","url_meta":{"origin":5753,"position":2},"title":"\u3010\u7b2c1\u56de\u3011Exosome\uff08\u30a8\u30af\u30bd\u30bd\u30fc\u30e0\uff0f\u30a8\u30ad\u30bd\u30bd\u30fc\u30e0\uff09\u3068\u306f\uff1f","author":"LatB Staff","date":"2026\u5e744\u670815\u65e5","format":false,"excerpt":"Exosome\uff08\u30a8\u30af\u30bd\u30bd\u30fc\u30e0\uff0f\u30a8\u30ad\u30bd\u30bd\u30fc\u30e0\uff09\u306e\u7814\u7a76\u304c\u6ce8\u76ee\u3092\u96c6\u3081\u3066\u3044\u307e\u3059\u3002\u8208\u5473\u306f\u3042\u3063\u3066\u3082\u3001\u3069\u306e\u3088\u3046\u306b\u7814\u2026","rel":"","context":"\u305d\u306e\u4ed6","block_context":{"text":"\u305d\u306e\u4ed6","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/else\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/03\/6fae859c8c1eacdaa39f3ae843ae1bda-scaled.png?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/03\/6fae859c8c1eacdaa39f3ae843ae1bda-scaled.png?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/03\/6fae859c8c1eacdaa39f3ae843ae1bda-scaled.png?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/03\/6fae859c8c1eacdaa39f3ae843ae1bda-scaled.png?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/03\/6fae859c8c1eacdaa39f3ae843ae1bda-scaled.png?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/03\/6fae859c8c1eacdaa39f3ae843ae1bda-scaled.png?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":23052,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/sanger-seq-ce-gsd-ts-ce-25058\/","url_meta":{"origin":5753,"position":3},"title":"\u3010\u3084\u3063\u3066\u307f\u305f\u3011\u3000\u65b0\u3057\u3044\u30d9\u30fc\u30b9\u30b3\u30fc\u30e9\u30fc\u3092\u6d3b\u7528\u3057\u305f\u3001\u30c0\u30d6\u30ebIndel\u5909\u7570\u306e\u691c\u51fa","author":"LatB Staff","date":"2025\u5e749\u670825\u65e5","format":false,"excerpt":"\u30c0\u30a4\u30ec\u30af\u30c8\u30b7\u30fc\u30b1\u30f3\u30b9\u6cd5\u306f\u3001\u76ee\u7684\u306e\u5869\u57fa\u914d\u5217\u3092\u53d6\u5f97\u3059\u308b\u624b\u6cd5\u3068\u3057\u3066\u5e83\u304f\u5229\u7528\u3055\u308c\u3066\u3044\u307e\u3059\u304c\u3001\u30d8\u30c6\u30ed\u63a5\u5408\u6027In\u2026","rel":"","context":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","block_context":{"text":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/mol-bio\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/09\/sanger-seq-ce-gsd-ts-ce-25058_eyecatch-scaled.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/09\/sanger-seq-ce-gsd-ts-ce-25058_eyecatch-scaled.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/09\/sanger-seq-ce-gsd-ts-ce-25058_eyecatch-scaled.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/09\/sanger-seq-ce-gsd-ts-ce-25058_eyecatch-scaled.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/09\/sanger-seq-ce-gsd-ts-ce-25058_eyecatch-scaled.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/09\/sanger-seq-ce-gsd-ts-ce-25058_eyecatch-scaled.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":24647,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/sanger-seq-mutational-analysis-gsd-ts-ce-26007\/","url_meta":{"origin":5753,"position":4},"title":"\u30de\u30a4\u30ca\u30fc\u5909\u7570\u3092\u691c\u51fa\uff01Minor Variant Finder\u30bd\u30d5\u30c8\u30a6\u30a8\u30a2","author":"LatB Staff","date":"2026\u5e742\u67089\u65e5","format":false,"excerpt":"\u30ad\u30e3\u30d4\u30e9\u30ea\u30fc\u30b7\u30fc\u30b1\u30f3\u30b5\u3067\u306f\u300125%\u7a0b\u5ea6\u306e\u5272\u5408\u306e\u5909\u7570\u3092\u691c\u51fa\u3059\u308b\u3053\u3068\u304c\u3067\u304d\u307e\u3059\u304c\u3001\u3053\u308c\u3088\u308a\u3082\u4f4e\u3044\u5272\u5408\u306e\u5909\u2026","rel":"","context":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","block_context":{"text":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/mol-bio\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/01\/sanger-seq-mutational-analysis-gsd-ts-ce-26007_eyecatch.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/01\/sanger-seq-mutational-analysis-gsd-ts-ce-26007_eyecatch.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/01\/sanger-seq-mutational-analysis-gsd-ts-ce-26007_eyecatch.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/01\/sanger-seq-mutational-analysis-gsd-ts-ce-26007_eyecatch.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/01\/sanger-seq-mutational-analysis-gsd-ts-ce-26007_eyecatch.jpg?resize=1050%2C600&ssl=1 3x"},"classes":[]},{"id":24953,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/ngs-gene-expression-csd-ts-ion-26011\/","url_meta":{"origin":5753,"position":5},"title":"\u30e9\u30a4\u30d6\u30e9\u30ea\u30fc\u8abf\u88fd\u306e\u81ea\u52d5\u5316\u3067NGS\u306e\u53ef\u80fd\u6027\u3092\u5e83\u3052\u308b\u2015Ion Chef\u30b7\u30b9\u30c6\u30e0\u304c\u5909\u3048\u308b\u7814\u7a76\u5ba4\u306e\u30ef\u30fc\u30af\u30d5\u30ed\u30fc","author":"LatB Staff","date":"2026\u5e744\u670810\u65e5","format":false,"excerpt":"\u524d\u51e6\u7406\u306e\u81ea\u52d5\u5316\u304c\u3001NGS\u306e\u65b0\u3057\u3044\u6a19\u6e96\u3092\u3064\u304f\u308b\u6b21\u4e16\u4ee3\u30b7\u30fc\u30b1\u30f3\u30b7\u30f3\u30b0\uff08NGS\uff09\u304c\u65e5\u5e38\u7684\u306a\u7814\u7a76\u30c4\u30fc\u30eb\u3068\u306a\u3063\u2026","rel":"","context":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","block_context":{"text":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/mol-bio\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/02\/ngs-gene-expression-csd-ts-ion-26011_eyecatch.jpeg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/02\/ngs-gene-expression-csd-ts-ion-26011_eyecatch.jpeg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/02\/ngs-gene-expression-csd-ts-ion-26011_eyecatch.jpeg?resize=525%2C300&ssl=1 1.5x"},"classes":[]}],"jetpack_sharing_enabled":true,"amp_enabled":true,"_links":{"self":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/posts\/5753","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/users\/988"}],"replies":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/comments?post=5753"}],"version-history":[{"count":0,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/posts\/5753\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/media\/5847"}],"wp:attachment":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/media?parent=5753"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/categories?post=5753"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/tags?post=5753"},{"taxonomy":"division","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/division?post=5753"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}