{"id":587,"date":"2017-02-09T00:00:00","date_gmt":"2017-02-09T00:00:00","guid":{"rendered":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/preprocessing-of-ion-chromatography\/"},"modified":"2023-08-17T15:12:37","modified_gmt":"2023-08-17T06:12:37","slug":"preprocessing-of-ion-chromatography","status":"publish","type":"post","link":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/preprocessing-of-ion-chromatography\/","title":{"rendered":"\u6b63\u78ba\u306a\u6e2c\u5b9a\u306e\u305f\u3081\u306b\uff01\u30a4\u30aa\u30f3\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc\u306b\u304a\u3051\u308b\u8a66\u6599\u306e\u524d\u51e6\u7406\u65b9\u6cd5\u3068\u6ce8\u610f\u70b9"},"content":{"rendered":"<h2>\u306f\u3058\u3081\u306b<\/h2>\n<p>\u30a4\u30aa\u30f3\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc\uff08IC\uff09\u306f\u6c34\u6eb6\u6db2\u8a66\u6599\u4e2d\u306b\u542b\u307e\u308c\u308b\u30a4\u30aa\u30f3\u6210\u5206\u3092\u6e2c\u5b9a\u3057\u307e\u3059\u3002\u8a66\u6599\u304c\u56fa\u4f53\u3084\u6c17\u4f53\u306e\u5834\u5408\u3001\u307e\u305a\u8a66\u6599\u3092\u6c34\u6eb6\u6db2\u5316\u3059\u308b\u51e6\u7406\u304c\u5fc5\u8981\u3067\u3059\u3002\u307e\u305f\u3001\u8a66\u6599\u6eb6\u6db2\u4e2d\u306b\u30ab\u30e9\u30e0\u3084\u30b5\u30d7\u30ec\u30c3\u30b5\u30fc\u306a\u3069\u3092\u52a3\u5316\u3055\u305b\u308b\u6210\u5206\u3084\u3001\u6e2c\u5b9a\u3092\u59a8\u5bb3\u3059\u308b\u6210\u5206\u304c\u5b58\u5728\u3059\u308b\u5834\u5408\u306f\u3001\u3053\u308c\u3089\u306e\u6210\u5206\u3092\u3042\u3089\u304b\u3058\u3081\u9664\u53bb\u3059\u308b\u51e6\u7406\u3082\u5fc5\u8981\u3067\u3059\u3002<\/p>\n<p><strong>\u4eca\u56de\u306f\u3001\u30a4\u30aa\u30f3\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc\u306b\u304a\u3051\u308b\u524d\u51e6\u7406\u306e\u65b9\u6cd5\u3001\u6ce8\u610f\u70b9\u306a\u3069\u306b\u3064\u3044\u3066\u3054\u7d39\u4ecb\u3057\u307e\u3059\u3002<\/strong><\/p>\n<h2>\u30a4\u30aa\u30f3\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc\u306b\u304a\u3051\u308b\u524d\u51e6\u7406<\/h2>\n<p><strong>\u524d\u51e6\u7406\u304c\u5fc5\u8981\u3067\u3042\u308b\u3068\u8003\u3048\u3089\u308c\u308b\u5834\u5408\u306f\u3001\u307e\u305a\u8a66\u6599\u60c5\u5831\u3092\u8a73\u7d30\u306b\u96c6\u3081\u308b\u5fc5\u8981\u304c\u3042\u308a\u307e\u3059\u3002<\/strong>\u5206\u6790\u76ee\u7684\u6210\u5206\u3001\u8a66\u6599\u306e\u72b6\u614b(\u30ac\u30b9\u3001\u6db2\u4f53\u3001\u56fa\u5f62\u7269\u2026)\u306a\u3069\u591a\u304f\u306e\u60c5\u5831\u3092\u96c6\u3081\u308b\u3053\u3068\u3067\u524d\u51e6\u7406\u3067\u3059\u308b\u3079\u304d\u9078\u629e\u80a2\u3082\u591a\u304f\u306a\u308a\u3001\u5206\u6790\u65b9\u6cd5\u306e\u9078\u629e\u80a2\u3082\u5897\u3048\u307e\u3059\u3002\u30a4\u30aa\u30f3\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc\u306b\u304a\u3051\u308b\u524d\u51e6\u7406\u306f\u4e3b\u306b\u4ee5\u4e0b\u306e\u624b\u9806\u306b\u5f93\u3063\u3066\u884c\u3044\u307e\u3059\u3002<\/p>\n<p><span style=\"text-decoration: underline\">\u30b9\u30c6\u30c3\u30d7I: \u6c34\u6eb6\u6db2\u5316<\/span><br \/>\n\u30a4\u30aa\u30f3\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc\u306f\u57fa\u672c\u7684\u306b\u6c34\u6eb6\u6db2\u8a66\u6599\u3092\u53d6\u308a\u6271\u3046\u5206\u6790\u6cd5\u3067\u3042\u308b\u305f\u3081\u3001\u8a66\u6599\u3092\u3042\u3089\u304b\u3058\u3081\u6c34\u6eb6\u6db2\u306b\u3059\u308b\u5fc5\u8981\u304c\u3042\u308a\u307e\u3059\u3002<\/p>\n<p><span style=\"text-decoration: underline\">\u30b9\u30c6\u30c3\u30d7II: \u52a3\u5316\u6210\u5206\u3068\u59a8\u5bb3\u6210\u5206\u306e\u9664\u53bb<\/span><br \/>\n\u30ab\u30e9\u30e0\u3001\u30b5\u30d7\u30ec\u30c3\u30b5\u30fc\u306a\u3069\u3092\u52a3\u5316\u3055\u305b\u308b\u6210\u5206\uff08\u52a3\u5316\u6210\u5206\uff09\u3068\u3001\u5206\u6790\u7a2e\u306e\u5206\u96e2\u691c\u51fa\u3092\u59a8\u5bb3\u3059\u308b\u30de\u30c8\u30ea\u30c3\u30af\u30b9\u6210\u5206\uff08\u59a8\u5bb3\u6210\u5206\uff09\u3092\u3042\u3089\u304b\u3058\u3081\u9664\u53bb\u3057\u307e\u3059\u3002<\/p>\n<p><span style=\"text-decoration: underline\">\u30b9\u30c6\u30c3\u30d7III: \u6fc3\u5ea6\u8abf\u6574<\/span><br \/>\n\u9069\u5207\u306a\u524d\u51e6\u7406\u3092\u884c\u3063\u305f\u5f8c\u3001\u5fc5\u8981\u3067\u3042\u308c\u3070\u7cbe\u5bc6\u5206\u6790\u3092\u3059\u308b\u305f\u3081\u306e\u6fc3\u5ea6\u8abf\u6574\u3092\u3057\u307e\u3059\u3002<\/p>\n<h3>\u30b9\u30c6\u30c3\u30d7I: \u6c34\u6eb6\u6db2\u5316<\/h3>\n<p>\u3055\u307e\u3056\u307e\u306a\u72b6\u614b\u306e\u8a66\u6599\u3092\u3001\u307e\u305a\u6700\u521d\u306b\u6c34\u6eb6\u6db2\u306b\u3057\u307e\u3059\u3002\u56f31\u306b\u3001\u305d\u306e\u4ee3\u8868\u7684\u306a\u30d5\u30ed\u30fc\u56f3\u3092\u793a\u3057\u3066\u3044\u307e\u3059\u3002<\/p>\n<div id=\"attachment_1692\" style=\"width: 1069px\" class=\"wp-caption aligncenter\"><a href=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/preprocessing-of-ion-chromatography-fig1.png\" rel=\"attachment wp-att-1692\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-1692\" class=\"size-full wp-image-1692\" src=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/preprocessing-of-ion-chromatography-fig1.png\" alt=\"preprocessing-of-ion-chromatography-fig1\" width=\"1059\" height=\"520\" \/><\/a><p id=\"caption-attachment-1692\" class=\"wp-caption-text\">\u56f31 \u6c34\u6eb6\u6db2\u5316\u306e\u30d5\u30ed\u30fc\u56f3<\/p><\/div>\n<h4>\u30ac\u30b9\u8a66\u6599<\/h4>\n<p>\u30ac\u30b9\u8a66\u6599\u3092\u6355\u96c6\u3057\u3066\u6db2\u5316\u3059\u308b\u524d\u51e6\u7406\u306f\u591a\u304f\u306e\u74b0\u5883\u5206\u6790\u3001\u56fa\u4f53\u71c3\u713c\u6355\u96c6\u5206\u6790\u3067\u4f7f\u7528\u3055\u308c\u3066\u3044\u307e\u3059\u3002\u3053\u306e\u3068\u304d\u6355\u96c6\u52b9\u7387\u3084\u5668\u5177\u304b\u3089\u306e\u6c5a\u67d3\u3092\u8003\u616e\u3057\u3066\u3001\u6700\u9069\u306a\u6355\u96c6\u65b9\u6cd5\u3092\u8003\u3048\u306a\u3051\u308c\u3070\u306a\u308a\u307e\u305b\u3093\u3002<strong>\u65e5\u672c\u5de5\u696d\u6a19\u6e96\u8abf\u67fb\u4f1a\u306eJIS\u306b\u5b9a\u3081\u3089\u308c\u305f\u5206\u6790\u65b9\u6cd5\u3092\u53c2\u7167\u3057\u3066\u691c\u8a0e\u3059\u308b\u3053\u3068\u3092\u304a\u52e7\u3081\u3057\u307e\u3059\u3002<\/strong>\u30a4\u30aa\u30f3\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc\u3067\u3088\u304f\u4f7f\u308f\u308c\u308b\u6355\u96c6\u65b9\u6cd5\u306b\u306f\u3001\u5438\u53ce\u74f6\u6cd5\u3068\u30d5\u30a3\u30eb\u30bf\u30fc\u6355\u96c6\u6cd5\u304c\u3042\u308a\u307e\u3059\u3002<\/p>\n<h5>\u5438\u53ce\u74f6\u6cd5<\/h5>\n<p><strong>\u30ac\u30b9\u8a66\u6599\u3092\u5438\u53ce\u6db2\u306b\u901a\u3057\u3066\u30a4\u30aa\u30f3\u6210\u5206\u3092\u6355\u96c6\u3059\u308b\u65b9\u6cd5\u3067\u3059\u3002\u30ac\u30b9\u6355\u96c6\u65b9\u6cd5\u3068\u3057\u3066\u306f\u3001\u3082\u3063\u3068\u3082\u591a\u304f\u7528\u3044\u3089\u308c\u3066\u3044\u308b\u524d\u51e6\u7406\u6cd5\u3067\u3059\u3002<\/strong>\u5438\u53ce\u6db2\u306b\u76ee\u7684\u30ac\u30b9\u3092\u5438\u53ce\u3067\u304d\u308b\u3082\u306e\u3092\u9078\u3073\u307e\u3059\u3002\u305f\u3068\u3048\u3070\u3001\u6c34\u6eb6\u6027\u306e\u9ad8\u3044\u30ac\u30b9\u306e\u5834\u5408\u306b\u306f\u8d85\u7d14\u6c34\u3092\u5438\u53ce\u6db2\u3068\u3057\u307e\u3059\u304c\u3001\u6c34\u6eb6\u6027\u306e\u4f4e\u3044\u30ac\u30b9\u306e\u5834\u5408\u306b\u306f\u3001\u904e\u9178\u5316\u6c34\u7d20\u6c34\u6eb6\u6db2\u306a\u3069\u304c\u3088\u304f\u7528\u3044\u3089\u308c\u307e\u3059\u3002\u5438\u53ce\u6db2\u6210\u5206\u306f\u6e2c\u5b9a\u3092\u59a8\u5bb3\u3059\u308b\u3053\u3068\u304c\u3042\u308b\u305f\u3081\u3001\u3042\u3089\u304b\u3058\u3081\u5438\u53ce\u6db2\u306e\u6fc3\u5ea6\u3084\u5438\u53ce\u6db2\u306e\u59a8\u5bb3\u306b\u3064\u3044\u3066\u691c\u8a0e\u3059\u308b\u5fc5\u8981\u304c\u3042\u308a\u307e\u3059\u3002<\/p>\n<ul>\n<li>\u5bfe\u8c61\u8a66\u6599\u4f8b\uff0d \u81ea\u52d5\u8eca\u6392\u30ac\u30b9\u3001\u5de5\u696d\u6392\u30ac\u30b9\u3001\u5ba4\u5185\u96f0\u56f2\u6c17\u3001\u30af\u30ea\u30fc\u30f3\u30eb\u30fc\u30e0\u5185\u96f0\u56f2\u6c17<\/li>\n<\/ul>\n<h5>\u30d5\u30a3\u30eb\u30bf\u30fc\u6355\u96c6\u6cd5<\/h5>\n<p><strong>\u30ac\u30b9\u8a66\u6599\u3092\u30d5\u30a3\u30eb\u30bf\u30fc\u306b\u901a\u3057\u3066\u30a4\u30aa\u30f3\u6210\u5206\u3092\u5438\u7740\u3057\u3066\u6355\u96c6\u3059\u308b\u65b9\u6cd5\u3067\u3059\u3002<\/strong>\u30c8\u30e9\u30c3\u30d7\u52b9\u7387\u3092\u4e0a\u3052\u308b\u305f\u3081\u306b\u3001\u30d5\u30a3\u30eb\u30bf\u30fc\u306b\u8a66\u85ac\u3092\u542b\u6d78\u3055\u305b\u308b\u3053\u3068\u304c\u3042\u308a\u307e\u3059\u3002\u5438\u7740\u3055\u305b\u305f\u6210\u5206\u3092\u8d85\u7d14\u6c34\u306a\u3069\u3067\u62bd\u51fa\u3057\u3066\u304b\u3089\u6e2c\u5b9a\u3059\u308b\u306e\u3067\u3001\u62bd\u51fa\u3059\u308b\u6642\u306f\u4e0d\u7d14\u7269\u306e\u6df7\u5165\u306b\u6ce8\u610f\u3057\u307e\u3059\u3002<\/p>\n<ul>\n<li>\u5bfe\u8c61\u8a66\u6599\u4f8b\uff0d\u5927\u6c17\u3001\u9727\u3001\u7c89\u5875\u3001\u30a8\u30a2\u30ed\u30be\u30eb<\/li>\n<\/ul>\n<h4>\u6db2\u4f53\u8a66\u6599<\/h4>\n<h5>\u6c34\u6eb6\u6db2\u8a66\u6599<\/h5>\n<p>\u57fa\u672c\u7684\u306b\u3001\u6c34\u306b\u6eb6\u3051\u3066\u3044\u308b\u5834\u5408\u306f\u7c92\u5b50\u3092\u308d\u904e\u3057\u3066\u304b\u3089\u6e2c\u5b9a\u304c\u53ef\u80fd\u3067\u3059\u3002<strong>\u4e00\u822c\u7684\u306b\u5b54\u5f840.45 \u03bcm\u4ee5\u4e0b\u306e\u30e1\u30f3\u30d6\u30e9\u30f3\u30d5\u30a3\u30eb\u30bf\u30fc\u3067\u306e\u51e6\u7406\u3092\u304a\u52e7\u3081\u3057\u307e\u3059\u3002<\/strong><\/p>\n<ul>\n<li>\u5bfe\u8c61\u8a66\u6599\u4f8b\uff0d\u6c34\u9053\u6c34\u3001\u6cb3\u5ddd\u6c34\u3001\u96e8\u6c34\u3001\u6392\u6c34\u306a\u3069<\/li>\n<\/ul>\n<h5>\u975e\u6c34\u6eb6\u6027\u8a66\u6599<\/h5>\n<p><strong>\u8a66\u6599\u304c\u975e\u6c34\u7cfb\u6eb6\u5a92\u3084\u6cb9\u306e\u5834\u5408\u3001\u8d85\u7d14\u6c34\u3084\u5e0c\u8584\u306a\u9178\u307e\u305f\u306f\u30a2\u30eb\u30ab\u30ea\u6eb6\u6db2\u3092\u52a0\u3048\u3001\u632f\u3068\u3046\u3057\u307e\u3059\u3002\u6e2c\u5b9a\u76ee\u7684\u30a4\u30aa\u30f3\u3092\u6c34\u5c64\u5074\u306b\u62bd\u51fa\u3057\u3001\u305d\u306e\u6c34\u5c64\u90e8\u3092\u6e2c\u5b9a\u306b\u7528\u3044\u307e\u3059\u3002<\/strong>\u9060\u5fc3\u5206\u96e2\u306f\u3001\u751f\u4f53\u6db2\u306a\u3069\u7c98\u6027\u306e\u9ad8\u3044\u8a66\u6599\u306e\u5206\u96e2\u3092\u4fc3\u9032\u3055\u305b\u308b\u306e\u306b\u52b9\u679c\u7684\u3067\u3059\u3002\u624b\u9806\u3068\u3057\u3066\u306f\u3001\u8a66\u6599\u3092\u9060\u5fc3\u5206\u96e2\u3057\u305f\u5f8c\u3001\u4e0a\u6f84\u6db2\u3092\u6e2c\u5b9a\u3057\u307e\u3059\u3002\u6c34\u306b\u6eb6\u89e3\u3057\u306a\u3044\u975e\u6c34\u6eb6\u6027\u6eb6\u5264\u306f\u306a\u3044\u306e\u3067\u3001\u6c34\u5c64\u90e8\u307e\u305f\u306f\u4e0a\u6f84\u6db2\u306f\u9006\u76f8\u7cfb\u56fa\u76f8\u62bd\u51fa\u30ab\u30fc\u30c8\u30ea\u30c3\u30b8\u306a\u3069\u306b\u901a\u3057\u3066\u3001\u975e\u6c34\u7cfb\u6eb6\u5264\u3092\u9664\u53bb\u3057\u3066\u304b\u3089\u6e2c\u5b9a\u3059\u308b\u3053\u3068\u3092\u304a\u52e7\u3081\u3057\u307e\u3059\u3002<\/p>\n<ul>\n<li>\u5bfe\u8c61\u8a66\u6599\u4f8b\uff0d\u975e\u6c34\u6eb6\u7cfb\u6eb6\u5a92\u3001\u6eb6\u5264\u3001\u6cb9<\/li>\n<\/ul>\n<h4>\u56fa\u5f62\u7269\u8a66\u6599<\/h4>\n<h5>\u8868\u9762\u4ed8\u7740\u30a4\u30aa\u30f3\u7a2e\u6210\u5206<\/h5>\n<p>\u975e\u6c34\u6eb6\u6027\u306e\u56fa\u4f53\u8a66\u6599\u306e\u8868\u9762\u306b\u4ed8\u7740\u3057\u3066\u3044\u308b\u30a4\u30aa\u30f3\u6210\u5206\u3092\u6e2c\u5b9a\u3059\u308b\u5834\u5408\u306f\u3001\u6c34\u62bd\u51fa\u3092\u884c\u3044\u307e\u3059\u3002<strong>\u5341\u5206\u306b\u6d17\u6d44\u3057\u305f\u30dd\u30ea\u30a8\u30c1\u30ec\u30f3\u306e\u888b\u306b\u8a66\u6599\u3068\u8d85\u7d14\u6c34\u3092\u5165\u308c\u3066\u5bc6\u5c01\u3057\u3001\u5fc5\u8981\u306b\u5fdc\u3058\u3066\u52a0\u6e29\u307e\u305f\u306f\u8d85\u97f3\u6ce2\u62bd\u51fa\u3092\u3057\u307e\u3059\u3002<\/strong>\u30dd\u30ea\u30a8\u30c1\u30ec\u30f3\u306e\u888b\u306e\u4ee3\u308f\u308a\u306b\u3001\u30c6\u30d5\u30ed\u30f3\u2122\u3067\u5185\u90e8\u8868\u9762\u3092\u30b3\u30fc\u30c6\u30a3\u30f3\u30b0\u3057\u305f\u5bb9\u5668\u3092\u7528\u3044\u308b\u3053\u3068\u3082\u3042\u308a\u307e\u3059\u3002\u56fa\u5f62\u7269\u8868\u9762\u4ed8\u7740\u30a4\u30aa\u30f3\u7a2e\u6210\u5206\u306e\u5206\u6790\u306f\u5fae\u91cf\u5206\u6790\u3092\u6c42\u3081\u3089\u308c\u308b\u3053\u3068\u304c\u591a\u304f\u3001\u7279\u306b\u96fb\u5b50\u90e8\u54c1\u306a\u3069\u306e\u8868\u9762\u30a4\u30aa\u30f3\u3092\u6e2c\u5b9a\u3059\u308b\u5834\u5408\u306f\u3001\u8d85\u9ad8\u611f\u5ea6\u5206\u6790\u304c\u6c42\u3081\u3089\u308c\u3001\u7d14\u6c34\u306e\u30b0\u30ec\u30fc\u30c9\u3001\u5bb9\u5668\u3001\u4f5c\u696d\u74b0\u5883\u306a\u3069\u591a\u304f\u306e\u524d\u51e6\u7406\u5de5\u7a0b\u3067\u6ce8\u610f\u304c\u5fc5\u8981\u3067\u3059\u3002<\/p>\n<ul>\n<li>\u5bfe\u8c61\u8a66\u6599\u4f8b\uff0d\u9ad8\u5206\u5b50\u6750\u3001\u96fb\u5b50\u90e8\u54c1\u3001\u975e\u6eb6\u89e3\u6027\u7269\u8cea<\/li>\n<\/ul>\n<h5>\u8d85\u7d14\u6c34\u306b\u6eb6\u89e3<\/h5>\n<p>\u8a66\u6599\u304c\u6c34\u6eb6\u6db2\u6027\u306e\u5834\u5408\u306f\u3001\u8d85\u7d14\u6c34\u306b\u6eb6\u89e3\u3055\u305b\u307e\u3059\u3002<strong>\u6fc3\u5ea6\u8a08\u7b97\u306e\u969b\u306b\u91cd\u91cf\uff0f\u91cd\u91cf\u306b\u63db\u7b97\u3059\u308b\u5fc5\u8981\u304c\u3042\u308b\u305f\u3081\u3001\u6eb6\u89e3\u51e6\u7406\u6642\u306e\u8a66\u6599\u91cd\u91cf\u3084\u6eb6\u89e3\u6db2\u306e\u5bb9\u7a4d\u3092\u6b63\u78ba\u306b\u8a18\u9332\u3057\u3066\u304a\u304d\u307e\u3059\u3002<\/strong><\/p>\n<ul>\n<li>\u5bfe\u8c61\u8a66\u6599\u4f8b\uff0d\u7c89\u672b\u8a66\u85ac\u3001\u6c34\u6eb6\u6027\u306e\u7c89\u672b\u306a\u3069<\/li>\n<\/ul>\n<h5>\u6709\u6a5f\u6eb6\u5a92\u306b\u6eb6\u89e3<\/h5>\n<p><strong>\u8a66\u6599\u304c\u6c34\u6eb6\u6db2\u3067\u306a\u304f\u6709\u6a5f\u6eb6\u5a92\u306b\u6eb6\u3051\u308b\u5834\u5408\u306f\u3001\u307e\u305a\u6700\u521d\u306b\u3001\u30ab\u30e9\u30e0\u306b\u5c0e\u5165\u53ef\u80fd\u306a\u6709\u6a5f\u6eb6\u5a92\u306b\u6eb6\u304b\u3057\u307e\u3059\u3002<\/strong>\u30ab\u30e9\u30e0\u306e\u7a2e\u985e\u306b\u3088\u3063\u3066\u306f\u3001\u6570\u03bcL\u7a0b\u5ea6\u3067\u3042\u308c\u3070\u30a2\u30bb\u30c8\u30cb\u30c8\u30ea\u30eb\u3084\u30e1\u30bf\u30ce\u30fc\u30eb\u3001\u30a8\u30bf\u30ce\u30fc\u30eb\u3092\u76f4\u63a5\u5c0e\u5165\u3059\u308b\u3053\u3068\u3082\u53ef\u80fd\u3067\u3059\u3002\u6c34\u3068\u5206\u96e2\u3059\u308b\u3088\u3046\u306a\u975e\u6975\u6027\u6709\u6a5f\u6eb6\u5a92\uff08\u30d9\u30f3\u30bc\u30f3\u3084\u30c8\u30eb\u30a8\u30f3\u306a\u3069\uff09\u306f\u3001\u30ab\u30e9\u30e0\u306b\u76f4\u63a5\u5c0e\u5165\u3059\u308b\u3053\u3068\u304c\u3067\u304d\u306a\u3044\u305f\u3081\u3001\u524d\u8ff0\u306e\u300c\u975e\u6c34\u6eb6\u6027\u8a66\u6599\u300d\u306e\u624b\u9806\u306b\u3088\u308a\u6db2\u6db2\u62bd\u51fa\u3092\u3057\u3001\u6c34\u5c64\u3092\u6e2c\u5b9a\u8a66\u6599\u3068\u3057\u307e\u3059\u3002<\/p>\n<ul>\n<li>\u5bfe\u8c61\u8a66\u6599\u4f8b\uff0d\u751f\u4f53\u8a66\u6599\u3001\u9ad8\u5206\u5b50\u6750\u3001\u9854\u6599\u306a\u3069<\/li>\n<\/ul>\n<h5>\u542b\u6c34\u8a66\u6599\u306e\u7c89\u7815\u51e6\u7406\u3068\u62bd\u51fa<\/h5>\n<p>\u91ce\u83dc\u3084\u679c\u7269\u306a\u3069\u306e\u3088\u3046\u306b\u6c34\u5206\u3092\u542b\u3093\u3067\u3044\u308b\u8a66\u6599\u306e\u5834\u5408\u3001\u3059\u308a\u3064\u3076\u3057\u3066\u5747\u8cea\u5316\u3057\u307e\u3059\u3002\u305d\u306e\u5f8c\u3001\u9060\u5fc3\u5206\u96e2\u3084\u30d5\u30a3\u30eb\u30bf\u30fc\u308d\u904e\u306a\u3069\u3067\u56fa\u5f62\u6210\u5206\u3092\u53d6\u308a\u9664\u304d\u3001\u4e0a\u6f84\u6db2\u3084\u308d\u904e\u6db2\u3092\u6e2c\u5b9a\u3057\u307e\u3059\u3002<\/p>\n<ul>\n<li>\u5bfe\u8c61\u8a66\u6599\u4f8b\uff0d\u91ce\u83dc\u3001\u679c\u7269\u3001\u30cf\u30e0\u306a\u3069<\/li>\n<\/ul>\n<h5>\u71c3\u713c\u5206\u89e3<\/h5>\n<p>\u30d7\u30e9\u30b9\u30c1\u30c3\u30af\u3084\u6709\u6a5f\u7269\u306a\u3069\u306e\u30cf\u30ed\u30b2\u30f3\u3084\u786b\u9ec4\u306a\u3069\u306e\u6e2c\u5b9a\u306b\u306f\u3001\u71c3\u713c\u5206\u89e3\u3068\u3044\u3046\u65b9\u6cd5\u304c\u3042\u308a\u307e\u3059\u3002\u8a66\u6599\u3092\u71c3\u713c\u88c5\u7f6e\u306a\u3069\u306b\u3088\u3063\u3066\u30cf\u30ed\u30b2\u30f3\u30ac\u30b9\u3084\u3001\u786b\u9ec4\u9178\u6027\u30ac\u30b9\u306b\u71c3\u713c\u5206\u89e3\u3055\u305b\u3001\u904e\u9178\u5316\u6c34\u7d20\u6c34\u6eb6\u6db2\u3067\u6355\u96c6\u3057\u6e2c\u5b9a\u8a66\u6599\u3068\u3057\u307e\u3059\u3002<\/p>\n<ul>\n<li>\u5bfe\u8c61\u8a66\u6599\u4f8b\uff0d\u9ad8\u5206\u5b50\u6750\u3001\u9320\u5264\u306a\u3069<\/li>\n<\/ul>\n<h3>\u30b9\u30c6\u30c3\u30d7II: \u52a3\u5316\u6210\u5206\u3068\u59a8\u5bb3\u6210\u5206\u306e\u9664\u53bb<\/h3>\n<h4>\u52a3\u5316\u6210\u5206<\/h4>\n<p><strong>\u52a3\u5316\u6210\u5206\u306b\u306f\u4e3b\u306b\u5fae\u7c92\u5b50\u3001\u53ef\u6eb6\u6027\u9ad8\u5206\u5b50\u3084\u3001\u91d1\u5c5e\u30a4\u30aa\u30f3\u3001\u6709\u6a5f\u6eb6\u5a92\u306a\u3069\u304c\u3042\u308a\u307e\u3059\u3002<\/strong>\u3053\u308c\u3089\u306e\u6210\u5206\u306f\u524d\u51e6\u7406\u306b\u3088\u3063\u3066\u9664\u53bb\u3057\u3001\u8a66\u6599\u3092\u30af\u30ea\u30fc\u30f3\u30a2\u30c3\u30d7\u3057\u3066\u304b\u3089\u5206\u6790\u3059\u308b\u3053\u3068\u3067\u3001\u9ad8\u3044\u7cbe\u5ea6\u306e\u7d50\u679c\u3092\u5f97\u308b\u3053\u3068\u304c\u3067\u304d\u3001\u30ab\u30e9\u30e0\u3084\u30b5\u30d7\u30ec\u30c3\u30b5\u30fc\u306e\u5bff\u547d\u3092\u5ef6\u3070\u3059\u6700\u9069\u306a\u65b9\u6cd5\u3067\u3059\u3002\u88681\u306b\u52a3\u5316\u6210\u5206\u306b\u3088\u308a\u751f\u3058\u305f\u4e0d\u5177\u5408\u304a\u3088\u3073\u305d\u306e\u9664\u53bb\u65b9\u6cd5\u3092\u307e\u3068\u3081\u3066\u3044\u307e\u3059\u3002<\/p>\n<table>\n<caption>\u88681 \u52a3\u5316\u6210\u5206\u306e\u7a2e\u985e\u304a\u3088\u3073\u9664\u53bb\u65b9\u6cd5<\/caption>\n<tbody>\n<tr>\n<td style=\"text-align: center\" colspan=\"2\"><strong>\u52a3\u5316\u6210\u5206<\/strong><\/td>\n<td style=\"text-align: center\"><strong>\u539f\u56e0\u3068\u75c7\u72b6<\/strong><\/td>\n<td style=\"text-align: center\"><strong>\u9664\u53bb\u65b9\u6cd5<\/strong><\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">\u5fae\u7c92\u5b50<\/td>\n<td>\u914d\u7ba1\u306e\u3064\u307e\u308a<br \/>\n\u30ab\u30e9\u30e0\u306e\u3064\u307e\u308a<\/td>\n<td>\u5b54\u5f840.45 \u03bcm\u4ee5\u4e0b\u306e\u30e1\u30f3\u30d6\u30e9\u30f3\u30d5\u30a3\u30eb\u30bf\u30fc\u3067\u308d\u904e<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"6\">\u53ef\u6eb6\u6027\u9ad8\u5206\u5b50<\/td>\n<td>\u754c\u9762\u6d3b\u6027\u5264<\/td>\n<td>\u30a4\u30aa\u30f3\u4ea4\u63db\u4f53\u306b\u5438\u7740<br \/>\n\u4fdd\u6301\u6642\u9593\u304c\u5909\u308f\u308b<\/td>\n<td>\u56fa\u76f8\u62bd\u51fa\uff08\u9006\u76f8\u7cfb\uff09<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"3\">\u30bf\u30f3\u30d1\u30af\u8cea<\/td>\n<td rowspan=\"3\">\u30a4\u30aa\u30f3\u4ea4\u63db\u4f53\u306b\u5438\u7740<br \/>\n\u30d4\u30fc\u30af\u5f62\u72b6\u306e\u7570\u5e38\u3001\u4e0d\u5206\u96e2\u3001\u30d4\u30fc\u30af\u5272\u308c<\/td>\n<td>\u5909\u6027\u3055\u305b\u3066\u4e0d\u6eb6\u5316\u3057\u3066\u9060\u5fc3\u5206\u96e2<\/td>\n<\/tr>\n<tr>\n<td>\u56fa\u76f8\u62bd\u51fa<\/td>\n<\/tr>\n<tr>\n<td>\u9650\u5916\u308d\u904e<\/td>\n<\/tr>\n<tr>\n<td>\u6cb9\u5206<\/td>\n<td>\u30a4\u30aa\u30f3\u4ea4\u63db\u4f53\u306b\u5438\u7740<br \/>\n\u30d4\u30fc\u30af\u5f62\u72b6\u306e\u7570\u5e38<\/td>\n<td>\u56fa\u76f8\u62bd\u51fa\uff08\u9006\u76f8\u7cfb\uff09<\/td>\n<\/tr>\n<tr>\n<td>\u67d3\u6599<\/td>\n<td>\u30a4\u30aa\u30f3\u4ea4\u63db\u4f53\u306b\u5438\u7740<br \/>\n\u4fdd\u6301\u6642\u9593\u304c\u5909\u308f\u308b<\/td>\n<td>\u56fa\u76f8\u62bd\u51fa\uff08\u9006\u76f8\u7cfb\uff09<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" rowspan=\"2\">\u91d1\u5c5e\u30a4\u30aa\u30f3<\/td>\n<td rowspan=\"2\">\u308a\u3093\u9178\u5b9a\u91cf\u5024\u306e\u7570\u5e38<br \/>\n\u30ab\u30e9\u30e0\u3001\u30b5\u30d7\u30ec\u30c3\u30b5\u30fc\u306e\u52a3\u5316<\/td>\n<td>\u30a2\u30eb\u30ab\u30ea\u6c88\u6bbf<\/td>\n<\/tr>\n<tr>\n<td>\u56fa\u76f8\u62bd\u51fa\uff08\u30a4\u30aa\u30f3\u4ea4\u63db\u6a39\u8102\u3001\u932f\u5f62\u6210\u5264\uff09<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" rowspan=\"2\">\u6709\u6a5f\u6eb6\u5a92<\/td>\n<td rowspan=\"2\">\u30a4\u30aa\u30f3\u4ea4\u63db\u4f53\u306e\u7834\u640d<br \/>\n\u4fdd\u6301\u6642\u9593\u306e\u6025\u306a\u5909\u5316<\/td>\n<td>\u6975\u6027\u6eb6\u5a92: \u30ab\u30e9\u30e0\u53d6\u6271\u8aac\u660e\u66f8\u53c2\u7167<\/td>\n<\/tr>\n<tr>\n<td>\u7121\u6975\u6027\u6eb6\u5a92: \u6db2\u6db2\u62bd\u51fa\u304a\u3088\u3073\u56fa\u76f8\u62bd\u51fa<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h5>\u5fae\u7c92\u5b50<\/h5>\n<p>\u76ee\u8996\u3067\u6d6e\u904a\u7269\u304c\u78ba\u8a8d\u3067\u304d\u306a\u304f\u3066\u3082\u3001\u5fae\u7c92\u5b50\u306e\u4e0d\u6eb6\u6210\u5206\u304c\u5b58\u5728\u3059\u308b\u3053\u3068\u304c\u591a\u304f\u3001<strong>\u88c5\u7f6e\u914d\u7ba1\u3084\u30ab\u30e9\u30e0\u3084\u30b5\u30d7\u30ec\u30c3\u30b5\u30fc\u306e\u3064\u307e\u308a\u306e\u539f\u56e0\u306b\u306a\u308b\u305f\u3081\u3001\u5fc5\u305a\u5b54\u5f840.45 \u03bcm\u4ee5\u4e0b\u306e\u30e1\u30f3\u30d6\u30e9\u30f3\u30d5\u30a3\u30eb\u30bf\u30fc\u3067\u8a66\u6599\u308d\u904e\u3092\u884c\u3044\u307e\u3059\u3002<\/strong>\u3053\u306e\u3068\u304d\u3001\u30d5\u30a3\u30eb\u30bf\u30fc\u304b\u3089\u306e\u6c5a\u67d3\u3092\u9632\u3050\u305f\u3081\u3001\u30d5\u30a3\u30eb\u30bf\u30fc\u306e\u6750\u8cea\u306b\u6ce8\u610f\u304c\u5fc5\u8981\u3067\u3059\u3002\u307e\u305f\u3001\u30d5\u30a3\u30eb\u30bf\u30fc\u81ea\u4f53\u3092\u8d85\u7d14\u6c34\u3067\u5341\u5206\u306b\u6d17\u6d44\u3057\u307e\u3059\u3002<\/p>\n<h5>\u53ef\u6eb6\u6027\u9ad8\u5206\u5b50<\/h5>\n<p><strong>\u4e3b\u306b\u754c\u9762\u6d3b\u6027\u5264\u3001\u30bf\u30f3\u30d1\u30af\u8cea\u3001\u6cb9\u5206\u3001\u67d3\u6599\u306a\u3069\u304c\u3042\u308a\u307e\u3059\u3002\u3053\u308c\u3089\u306e\u6210\u5206\u306f\u30ab\u30e9\u30e0\u5185\u306e\u30a4\u30aa\u30f3\u4ea4\u63db\u4f53\u306b\u5f37\u304f\u5438\u7740\u3055\u308c\u3001\u76ee\u7684\u6210\u5206\u306e\u4fdd\u6301\u6642\u9593\u304c\u77ed\u304f\u306a\u308a\u3001\u30d4\u30fc\u30af\u304c\u5d29\u308c\u307e\u3059\u3002<\/strong>\u56f32\u306b\u793a\u3057\u305f\u3088\u3046\u306b\u3001\u53ef\u6eb6\u6027\u9ad8\u5206\u5b50\u3067\u3042\u308b\u30d5\u30df\u30f3\u9178\u3092\u542b\u3080\u8a66\u6599\u309210 \u03bcL\u306720\u56de\u5c0e\u5165\u3057\u305f\u5f8c\u3001\u5404\u6210\u5206\u306e\u4fdd\u6301\u6642\u9593\u304c20%\u4ee5\u4e0a\u3082\u77ed\u304f\u306a\u308a\u3001\u30d4\u30fc\u30af\u5f62\u72b6\u304c\u60aa\u304f\u306a\u3063\u305f\u3053\u3068\u304c\u308f\u304b\u308a\u307e\u3059\u3002<\/p>\n<div id=\"attachment_1694\" style=\"width: 686px\" class=\"wp-caption aligncenter\"><a href=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/preprocessing-of-ion-chromatography-fig2.png\" rel=\"attachment wp-att-1694\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-1694\" class=\"size-full wp-image-1694\" src=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/preprocessing-of-ion-chromatography-fig2.png\" alt=\"preprocessing-of-ion-chromatography-fig2\" width=\"676\" height=\"543\" \/><\/a><p id=\"caption-attachment-1694\" class=\"wp-caption-text\">\u56f32 \u53ef\u6eb6\u6027\u9ad8\u5206\u5b50\u306e\u5f71\u97ff\u3002\u5206\u6790\u6761\u4ef6 \u30ab\u30e9\u30e0: Thermo Scientific\u2122 Dionex\u2122 IonPac\u2122 AG17\/AS17\u3001\u30ab\u30e9\u30e0\u6e29\u5ea6: 30\u2103\u3001\u6eb6\u96e2\u6db2: 15 mmol\/L NaOH\u3001\u6d41\u91cf: 1.0 mL\/min\u3001\u691c\u51fa\u5668: \u96fb\u6c17\u4f1d\u5c0e\u5ea6\uff08\u30b5\u30d7\u30ec\u30c3\u30b5\u30fc\u4f7f\u7528\uff09\u3001\u8a66\u6599\u6ce8\u5165\u91cf: 10 \u03bcL<\/p><\/div>\n<h5>\u91d1\u5c5e\u30a4\u30aa\u30f3<\/h5>\n<p><strong>\u6eb6\u96e2\u6db2\u306b\u6df7\u305c\u308b\u3068\u6c88\u6bbf\u304c\u751f\u6210\u3059\u308b\u91d1\u5c5e\u30a4\u30aa\u30f3\u304c\u3042\u308a\u307e\u3059\u3002\u3053\u308c\u3089\u306e\u6210\u5206\u3092\u542b\u3093\u3060\u8a66\u6599\u3092\u76f4\u63a5\u5c0e\u5165\u3059\u308b\u3068\u3001\u914d\u7ba1\u3084\u30ab\u30e9\u30e0\u3084\u30b5\u30d7\u30ec\u30c3\u30b5\u30fc\u306e\u3064\u307e\u308a\u306e\u539f\u56e0\u3068\u306a\u308b\u305f\u3081\u3042\u3089\u304b\u3058\u3081\u9664\u53bb\u3059\u308b\u3053\u3068\u304c\u5fc5\u8981\u3067\u3059\u3002<\/strong>\u307e\u305f\u91d1\u5c5e\u30a4\u30aa\u30f3\u3068\u5f62\u6210\u3057\u3066\u4e0d\u89e3\u96e2\u306a\u72b6\u614b\u306b\u306a\u308b\u3088\u3046\u306a\u6210\u5206\uff08\u308a\u3093\u9178\u30a4\u30aa\u30f3\u306a\u3069\uff09\u3092\u6e2c\u5b9a\u3059\u308b\u5834\u5408\u306f\u3001\u611f\u5ea6\u304c\u4f4e\u4e0b\u3059\u308b\u3053\u3068\u304c\u3042\u308b\u305f\u3081\u91d1\u5c5e\u30a4\u30aa\u30f3\u306e\u9664\u53bb\u3092\u884c\u3044\u307e\u3059\u3002<\/p>\n<h5>\u6709\u6a5f\u6eb6\u5a92<\/h5>\n<p><strong>\u6709\u6a5f\u6eb6\u5a92\u306e\u7a2e\u985e\u306b\u3082\u3088\u308a\u307e\u3059\u304c\u3001\u76f4\u63a5\u5c0e\u5165\u3059\u308b\u3068\u30a4\u30aa\u30f3\u4ea4\u63db\u4f53\u304c\u81a8\u6f64\u3001\u307e\u305f\u306f\u53ce\u7e2e\u3057\u3066\u30ab\u30e9\u30e0\u304c\u58ca\u308c\u308b\u3053\u3068\u304c\u3042\u308a\u307e\u3059\u3002<\/strong>\u975e\u6975\u6027\u6709\u6a5f\u6eb6\u5a92\uff08\u30d9\u30f3\u30bc\u30f3\u3084\u30c8\u30eb\u30a8\u30f3\u306a\u3069\uff09\u306e\u5834\u5408\u3001\u6db2\u6db2\u62bd\u51fa\u3057\u305f\u306e\u3061\u3001\u9006\u76f8\u30ab\u30fc\u30c8\u30ea\u30c3\u30b8\u3092\u901a\u904e\u3055\u305b\u308b\u5fc5\u8981\u304c\u3042\u308a\u307e\u3059\u3002\u6975\u6027\u6709\u6a5f\u6eb6\u5a92\u306e\u5834\u5408\u3001\u6570\u03bcL\u7a0b\u5ea6\u3067\u3042\u308c\u3070\u30a2\u30bb\u30c8\u30cb\u30c8\u30ea\u30eb\u3084\u30e1\u30bf\u30ce\u30fc\u30eb\u3001\u30a8\u30bf\u30ce\u30fc\u30eb\u3092\u76f4\u63a5\u5c0e\u5165\u3059\u308b\u3053\u3068\u3082\u53ef\u80fd\u3067\u3059\u3002<\/p>\n<h4>\u59a8\u5bb3\u6210\u5206<\/h4>\n<p><strong>\u5206\u6790\u7a2e\u306e\u5206\u96e2\u3084\u691c\u51fa\u306b\u5f71\u97ff\u3092\u304a\u3088\u307c\u3059\u5834\u5408\u3001\u6e2c\u5b9a\u3092\u59a8\u5bb3\u3059\u308b\u3088\u3046\u306a\u6210\u5206\u306f\u53d6\u308a\u9664\u304f\u5fc5\u8981\u304c\u3042\u308a\u307e\u3059\u3002\u4ee3\u8868\u7684\u306a\u8a66\u6599\u3068\u3057\u3066\u6d77\u6c34\u304c\u3042\u308a\u307e\u3059\u3002<\/strong>\u6d77\u6c34\u4e2d\u306e\u9670\u30a4\u30aa\u30f3\u5206\u6790\u3067\u306f\u3001\u9ad8\u6fc3\u5ea6\u306e\u5869\u5316\u7269\u30a4\u30aa\u30f3\u306e\u5f71\u97ff\u3067\u4ed6\u306e\u9670\u30a4\u30aa\u30f3\u304c\u6e2c\u5b9a\u3067\u304d\u306a\u3044\u3053\u3068\u304c\u3042\u308a\u307e\u3059\u3002\u30ab\u30e9\u30e0\u3084\u30b5\u30d7\u30ec\u30c3\u30b5\u30fc\u304c\u52a3\u5316\u3059\u308b\u3053\u3068\u306f\u3042\u308a\u307e\u305b\u3093\u304c\u3001\u9ad8\u6fc3\u5ea6\u306b\u542b\u307e\u308c\u308b\u6210\u5206\u30d4\u30fc\u30af\u524d\u5f8c\u306b\u6eb6\u51fa\u3059\u308b\u30a4\u30aa\u30f3\u6210\u5206\u306b\u3001\u5f37\u304f\u5f71\u97ff\u304c\u898b\u3089\u308c\u307e\u3059\u3002<\/p>\n<h3>\u30b9\u30c6\u30c3\u30d7III: \u6fc3\u5ea6\u8abf\u6574<\/h3>\n<p><strong>\u9069\u5207\u306a\u524d\u51e6\u7406\u3092\u884c\u3063\u305f\u8a66\u6599\u306f\u3001\u7cbe\u5bc6\u5206\u6790\u3092\u3059\u308b\u305f\u3081\u306e\u6fc3\u5ea6\u8abf\u6574\u3092\u3057\u307e\u3059\u3002<\/strong>\u30a4\u30aa\u30f3\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc\u3067\u306f\u8a66\u6599\u4e2d\u306e\u76ee\u7684\u30a4\u30aa\u30f3\u7a2e\u6210\u5206\u3092\u5b9a\u91cf\u3059\u308b\u3068\u304d\u306b\u3001\u5916\u90e8\u691c\u91cf\u7dda\u6cd5\u3092\u63a1\u7528\u3057\u3066\u3044\u307e\u3059\u3002\u691c\u91cf\u7dda\u306f\u30a4\u30aa\u30f3\u306e\u7a2e\u985e\u3084\u6eb6\u96e2\u6db2\u306e\u7a2e\u985e\u306b\u3088\u3063\u3066\u3001\u76f4\u7dda\u6027\u306e\u7bc4\u56f2\u304c\u7570\u306a\u308a\u307e\u3059\u3002\u591a\u304f\u306e\u30a4\u30aa\u30f3\u7a2e\u6210\u5206\u3067\u306f\u76f4\u7dda\u306b\u306a\u308a\u96e3\u3044\u6210\u5206\u3070\u304b\u308a\u3067\u3001\u76f4\u7dda\u6027\u306e\u7bc4\u56f2\u3082\u72ed\u3044\u3082\u306e\u3070\u304b\u308a\u3067\u3059\u3002<strong>\u7cbe\u5bc6\u5206\u6790\u3059\u308b\u305f\u3081\u306b\u306f\u3001\u3067\u304d\u308b\u3060\u3051\u691c\u91cf\u7dda\u306e\u7bc4\u56f2\u3092\u72ed\u304f\u3057\u3066\u3001\u8a66\u6599\u6e2c\u5b9a\u306e\u969b\u306e\u5fdc\u7b54\u5024\u304c\u305d\u306e\u7bc4\u56f2\u306b\u5165\u308b\u3088\u3046\u306b\u8abf\u6574\u3092\u3059\u308b\u5fc5\u8981\u304c\u3042\u308a\u307e\u3059\u3002<\/strong><\/p>\n<h4>\u5e0c\u91c8<\/h4>\n<p><strong>\u6e2c\u5b9a\u6210\u5206\u306e\u6fc3\u5ea6\u304c\u9ad8\u3044\u5834\u5408\u3001\u691c\u91cf\u7dda\u306e\u76f4\u7dda\u7bc4\u56f2\u4ee5\u5185\u306b\u8a66\u6599\u3092\u5e0c\u91c8\u3059\u308b\u5fc5\u8981\u304c\u3042\u308a\u307e\u3059\u3002<\/strong>\u3044\u308f\u3086\u308b\u5e0c\u91c8\u524d\u51e6\u7406\u3067\u3059\u3002\u307e\u305f\u3001\u6e2c\u5b9a\u6210\u5206\u306e\u6fc3\u5ea6\u304c\u9069\u6b63\u3067\u3082\u3001<strong>\u59a8\u5bb3\u6210\u5206\uff08\u30de\u30c8\u30ea\u30c3\u30af\u30b9\uff09\u304c\u9ad8\u3044\u5834\u5408\u3001\u5e0c\u91c8\u524d\u51e6\u7406\u306f\u6709\u52b9\u306a\u65b9\u6cd5\u3067\u3059\u3002<\/strong>\u30ab\u30e9\u30e0\u306e\u30a4\u30aa\u30f3\u4ea4\u63db\u5bb9\u91cf\u306f\u56fa\u5b9a\u3055\u308c\u3066\u304a\u308a\u3001\u9ad8\u6fc3\u5ea6\u30de\u30c8\u30ea\u30c3\u30af\u30b9\u306b\u3088\u308a\u30a4\u30aa\u30f3\u4ea4\u63db\u4f53\u306e\u4ea4\u63db\u57fa\u304c\u585e\u304c\u308c\u3001\u30a4\u30aa\u30f3\u4ea4\u63db\u80fd\u304c\u4e00\u6642\u7684\u306b\u4f4e\u4e0b\u3057\u3066\u5206\u96e2\u4e0d\u5168\u3092\u8d77\u3053\u3059\u3053\u3068\u304c\u3042\u308a\u307e\u3059\u3002\u3053\u306e\u30de\u30c8\u30ea\u30c3\u30af\u30b9\u6fc3\u5ea6\u3092\u4e0b\u3052\u308b\u305f\u3081\u306b\u5e0c\u91c8\u524d\u51e6\u7406\u304c\u5fc5\u8981\u3067\u3059\u3002<\/p>\n<h4>\u6fc3\u7e2e<\/h4>\n<p><strong>\u8a66\u6599\u4e2d\u306e\u76ee\u7684\u30a4\u30aa\u30f3\u6210\u5206\u304c\u6975\u4f4e\u6fc3\u5ea6\u3067\u3042\u308b\u5834\u5408\uff08\u03bcg\/L\u30ec\u30d9\u30eb\uff09\u3001\u6fc3\u7e2e\u5c0e\u5165\u6cd5\u3092\u7528\u3044\u3066\u5fdc\u7b54\u5024\u3092\u9ad8\u3081\u307e\u3059\u3002<\/strong>\u56f33\u306b\u793a\u3057\u305f\u3088\u3046\u306b\u3001\u8a66\u6599\u30eb\u30fc\u30d7\u306e\u4ee3\u308f\u308a\u306b\u6fc3\u7e2e\u30ab\u30e9\u30e0\u3092\u5c0e\u5165\u30d0\u30eb\u30d6\u306b\u53d6\u308a\u4ed8\u3051\u307e\u3059\u3002\u8a66\u6599\u5c0e\u5165\u7528\u30dd\u30f3\u30d7\u3092\u7528\u3044\u3066\u4e00\u5b9a\u91cf\u306e\u8a66\u6599\u3092\u6fc3\u7e2e\u30ab\u30e9\u30e0\u306b\u5c0e\u5165\u3057\u3001\u30a4\u30aa\u30f3\u6210\u5206\u3092\u6fc3\u7e2e\u3055\u305b\u3066\u304b\u3089\u5206\u6790\u30ab\u30e9\u30e0\u3092\u7528\u3044\u3066\u6e2c\u5b9a\u3057\u307e\u3059\u300210 mL\u6fc3\u7e2e\u5c0e\u5165\u306b\u3088\u3063\u30660.1 \uff5e 0.5 \u03bcg\/L\u306e\u9670\u30a4\u30aa\u30f3\u3092\u611f\u5ea6\u3088\u304f\u6e2c\u5b9a\u3067\u304d\u307e\u3059\uff08\u56f34\uff09\u3002<\/p>\n<div id=\"attachment_1695\" style=\"width: 1129px\" class=\"wp-caption aligncenter\"><a href=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/preprocessing-of-ion-chromatography-fig3.png\" rel=\"attachment wp-att-1695\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-1695\" class=\"size-full wp-image-1695\" src=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/preprocessing-of-ion-chromatography-fig3.png\" alt=\"preprocessing-of-ion-chromatography-fig3\" width=\"1119\" height=\"356\" \/><\/a><p id=\"caption-attachment-1695\" class=\"wp-caption-text\">\u56f33 \u6fc3\u7e2e\u5c0e\u5165\u6cd5\u306e\u914d\u7ba1<\/p><\/div>\n<div id=\"attachment_1696\" style=\"width: 1007px\" class=\"wp-caption aligncenter\"><a href=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/preprocessing-of-ion-chromatography-fig4.png\" rel=\"attachment wp-att-1696\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-1696\" class=\"size-full wp-image-1696\" src=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/preprocessing-of-ion-chromatography-fig4.png\" alt=\"preprocessing-of-ion-chromatography-fig4\" width=\"997\" height=\"569\" \/><\/a><p id=\"caption-attachment-1696\" class=\"wp-caption-text\">\u56f34 \u03bcg\/L \u30ec\u30d9\u30eb\u6a19\u6e96\u6db2\u306e\u6fc3\u7e2e\u5206\u6790\u4f8b\u3002\u5206\u6790\u6761\u4ef6 \u30ab\u30e9\u30e0: Dionex IonPac AS17-C\/AG17-C\u3001\u6eb6\u96e2\u6db2: KOH\u30b0\u30e9\u30b8\u30a8\u30f3\u30c8\u3001\u6d41\u91cf: 1.0 mL\/min\u3001\u691c\u51fa\u5668: \u96fb\u6c17\u4f1d\u5c0e\u5ea6\uff08\u30b5\u30d7\u30ec\u30c3\u30b5\u30fc\u4f7f\u7528\uff09\u3001\u70ad\u9178\u9664\u53bb\u30c7\u30d0\u30a4\u30b9CRD\u4f7f\u7528\u3001\u8a66\u6599\u6fc3\u7e2e\u91cf: 10 mL<\/p><\/div>\n<h2>\u56fa\u76f8\u62bd\u51fa<\/h2>\n<p><strong>\u88681\u3067\u793a\u3057\u3066\u3044\u308b\u3088\u3046\u306b\u3001\u52a3\u5316\u6210\u5206\u3068\u59a8\u5bb3\u6210\u5206\u3092\u53d6\u308a\u9664\u304f\u305f\u3081\u56fa\u76f8\u62bd\u51fa\u30ab\u30fc\u30c8\u30ea\u30c3\u30b8\u304c\u3088\u304f\u4f7f\u308f\u308c\u3066\u3044\u307e\u3059\u3002<\/strong>\u56fa\u76f8\u62bd\u51fa\u30ab\u30fc\u30c8\u30ea\u30c3\u30b8\u306e\u4f7f\u7528\u65b9\u6cd5\u306f\u4e8c\u901a\u308a\u3042\u308a\u307e\u3059\u3002\u9664\u53bb\u6210\u5206\u3092\u4fdd\u6301\u3057\u3066\u76ee\u7684\u30a4\u30aa\u30f3\u7a2e\u6210\u5206\u3092\u901a\u904e\u3055\u305b\u3066\u5206\u96e2\u9664\u53bb\u3059\u308b\u65b9\u6cd5\u3068\u3001\u76ee\u7684\u30a4\u30aa\u30f3\u7a2e\u3092\u4fdd\u6301\u3057\u9664\u53bb\u6210\u5206\u3092\u901a\u904e\u6392\u51fa\u5f8c\u306b\u6eb6\u96e2\u6eb6\u5a92\u3067\u76ee\u7684\u30a4\u30aa\u30f3\u7a2e\u6210\u5206\u3092\u6fc3\u7e2e\u56de\u53ce\u3059\u308b\u65b9\u6cd5\u3067\u3059\u3002\u30a4\u30aa\u30f3\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc\u3067\u306f\u3001\u4e00\u822c\u7684\u306b\u524d\u65b9\u6cd5\u3092\u4f7f\u7528\u3057\u307e\u3059\u3002\u5f8c\u65b9\u6cd5\u306f\u6db2\u4f53\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u6cd5\u3067\u306e\u524d\u51e6\u7406\u306b\u7528\u3044\u308b\u56fa\u76f8\u62bd\u51fa\u65b9\u6cd5\u3067\u3001\u30a4\u30aa\u30f3\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc\u306b\u4f7f\u308f\u308c\u308b\u3068\u3001\u6eb6\u96e2\u5264\u8a66\u85ac\u305d\u306e\u3082\u306e\u304c\u4eca\u5ea6\u306f\u59a8\u5bb3\u6210\u5206\u306b\u306a\u3063\u3066\u3057\u307e\u3046\u305f\u3081\u4f7f\u7528\u3057\u307e\u305b\u3093\u3002<strong>\u56fa\u76f8\u62bd\u51fa\u30ab\u30fc\u30c8\u30ea\u30c3\u30b8\u306b\u5145\u586b\u3055\u308c\u305f\u5145\u586b\u5264\u306e\u7a2e\u985e\u306b\u3088\u3063\u3066\u4f7f\u7528\u76ee\u7684\u304c\u5206\u304b\u308c\u3066\u3044\u308b\u306e\u3067\u3001\u9664\u53bb\u6210\u5206\u3068\u6e2c\u5b9a\u30a4\u30aa\u30f3\u7a2e\u6210\u5206\u3092\u8003\u616e\u3057\u306a\u304c\u3089\u9078\u629e\u3057\u307e\u3059\u3002<\/strong>\u88682\u306b\u5f0a\u793e\u306e\u56fa\u76f8\u62bd\u51fa\u30ab\u30fc\u30c8\u30ea\u30c3\u30b8\u3092\u793a\u3057\u307e\u3059\u3002<a href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/industrial\/chromatography\/ion-chromatography-ic\/ic-consumables\/ic-sample-preparation.html?ICID=cmd_ic_r04_jp_preprocessing_of_ion_chromatography_Social_LAB\n\" target=\"_blank\" rel=\"noopener noreferrer\">Thermo Scientific Dionex OnGuard\u2122 II<\/a>\u306f\u30aa\u30d5\u30e9\u30a4\u30f3\u3067\u4f7f\u7528\u3059\u308b\u30bf\u30a4\u30d7\u3067\u3001<a href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/industrial\/chromatography\/ion-chromatography-ic\/ic-consumables\/ic-sample-preparation.html?ICID=cmd_ic_r04_jp_preprocessing_of_ion_chromatography_Social_LAB\n\" target=\"_blank\" rel=\"noopener noreferrer\">Thermo Scientific Dionex InGuard\u2122<\/a>\u306f\u30aa\u30f3\u30e9\u30a4\u30f3\u3067\u4f7f\u7528\u3059\u308b\u30bf\u30a4\u30d7\u3067\u3059\u3002<\/p>\n<table>\n<caption>\u88682 \u5f0a\u793e\u306e\u56fa\u76f8\u62bd\u51fa\u30ab\u30fc\u30c8\u30ea\u30c3\u30b8<\/caption>\n<tbody>\n<tr>\n<td><strong>\u7a2e\u985e<\/strong><\/td>\n<td><strong>\u5145\u586b\u5264<\/strong><\/td>\n<td><strong>\u4e3b\u306a\u7528\u9014<\/strong><\/td>\n<td><strong>OnGuard<\/strong><\/td>\n<td><strong>InGuard<\/strong><\/td>\n<\/tr>\n<tr>\n<td>A<\/td>\n<td>\u91cd\u70ad\u9178\u30a4\u30aa\u30f3\u578b\u3001\u9670\u30a4\u30aa\u30f3\u4ea4\u63db<\/td>\n<td>\u4e2d\u548c\u3001\u9670\u30a4\u30aa\u30f3\u306e\u9664\u53bb<\/td>\n<td style=\"text-align: center\">\u25ef<\/td>\n<td style=\"text-align: center\"><\/td>\n<\/tr>\n<tr>\n<td>H<\/td>\n<td>\u6c34\u7d20\u30a4\u30aa\u30f3\u578b\u3001\u967d\u30a4\u30aa\u30f3\u4ea4\u63db<\/td>\n<td>\u30a2\u30eb\u30ab\u30ea\u91d1\u5c5e\u3001\u30a2\u30eb\u30ab\u30ea\u571f\u985e\u91d1\u5c5e\u3001\u9077\u79fb\u91d1\u5c5e\u306e\u9664\u53bb\u3001\u4e2d\u548c<\/td>\n<td style=\"text-align: center\">\u25ef<\/td>\n<td style=\"text-align: center\">\u25ef<\/td>\n<\/tr>\n<tr>\n<td>Na<\/td>\n<td>\u30ca\u30c8\u30ea\u30a6\u30e0\u30a4\u30aa\u30f3\u578b\u3001\u967d\u30a4\u30aa\u30f3\u4ea4\u63db<\/td>\n<td>\u30a2\u30eb\u30ab\u30ea\u571f\u985e\u91d1\u5c5e\u3001\u9077\u79fb\u91d1\u5c5e\u306e\u9664\u53bb\uff08pH\u5909\u5316\u306a\u3057\uff09<br \/>\nOnGuard II Ag\u4f7f\u7528\u6642\u306b\u4e9c\u785d\u9178\u56de\u53ce\u7387\u3092\u7dad\u6301\u3057\u305f\u3044\u5834\u5408<\/td>\n<td style=\"text-align: center\">\u25ef<\/td>\n<td style=\"text-align: center\">\u25ef<\/td>\n<\/tr>\n<tr>\n<td>M<\/td>\n<td>\u30a2\u30f3\u30e2\u30cb\u30a6\u30e0\u578b\u3001\u30a4\u30df\u30ce\u30b8\u9162\u9178<\/td>\n<td>\u9077\u79fb\u91d1\u5c5e\u306e\u6fc3\u7e2e\uff0f\u9664\u53bb<\/td>\n<td style=\"text-align: center\">\u25ef<\/td>\n<td style=\"text-align: center\"><\/td>\n<\/tr>\n<tr>\n<td>P<\/td>\n<td>\u30dd\u30ea\u30d3\u30cb\u30eb\u3001\u30d4\u30ed\u30ea\u30c9\u30f3<\/td>\n<td>\u30d5\u30a7\u30ce\u30fc\u30eb\u3001\u30a2\u30be\u8272\u7d20\u3001\u30d5\u30df\u30f3\u9178\u306e\u9664\u53bb<\/td>\n<td style=\"text-align: center\">\u25ef<\/td>\n<td style=\"text-align: center\"><\/td>\n<\/tr>\n<tr>\n<td>RP<\/td>\n<td>\u30dd\u30ea\u30b8\u30d3\u30cb\u30eb\u3001\u30d9\u30f3\u30bc\u30f3<\/td>\n<td>\u82b3\u9999\u65cf\u67d3\u6599\u3001\u70ad\u5316\u6c34\u7d20\u3001\u754c\u9762\u6d3b\u6027\u5264\u3001\u9ad8\u7d1a\u8102\u80aa\u9178\u306a\u3069\u306e\u9664\u53bb<\/td>\n<td style=\"text-align: center\">\u25ef<\/td>\n<td style=\"text-align: center\"><\/td>\n<\/tr>\n<tr>\n<td>HRP<\/td>\n<td>\u89aa\u6c34\u6027\u3001\u30b8\u30d3\u30cb\u30eb\u30d9\u30f3\u30bc\u30f3<\/td>\n<td>\u758e\u6c34\u6027\u7269\u8cea\u3001\u30a2\u30be\u8272\u7d20\u304a\u3088\u3073\u30b7\u30a2\u30ce\u57fa\u3092\u6301\u3064\u7269\u8cea\u306e\u9664\u53bb<\/td>\n<td style=\"text-align: center\"><\/td>\n<td style=\"text-align: center\">\u25ef<\/td>\n<\/tr>\n<tr>\n<td>Na\/HRP<\/td>\n<td>\u4e8c\u5b98\u80fd\u57fa\u6027<\/td>\n<td>Ca<sup>2+<\/sup>(Na) \u3068\u8102\u8cea(HRP) \u3092\u4e73\u88fd\u54c1\u304b\u3089\u9664\u53bb<\/td>\n<td style=\"text-align: center\"><\/td>\n<td style=\"text-align: center\">\u25ef<\/td>\n<\/tr>\n<tr>\n<td>Ag<\/td>\n<td>\u9280\u578b\u967d\u30a4\u30aa\u30f3\u4ea4\u63db<\/td>\n<td>\u30cf\u30ed\u30b2\u30f3\u3001CrO<sub>4<\/sub><sup>2-<\/sup>\u3001CN<sup>&#8211;<\/sup>\u3001S<sup>2-<\/sup>\u3001SCN<sup>&#8211;<\/sup>\u306a\u3069\u306e\u9664\u53bb\u3001OnGuard II H \u3068\u306e\u4f75\u7528\u3092\u63a8\u5968<\/td>\n<td style=\"text-align: center\">\u25ef<\/td>\n<td style=\"text-align: center\">\u25ef<\/td>\n<\/tr>\n<tr>\n<td>Ba<\/td>\n<td>\u30d0\u30ea\u30a6\u30e0\u30a4\u30aa\u30f3\u578b\u967d\u3001\u30a4\u30aa\u30f3\u4ea4\u63db<\/td>\n<td>\u786b\u9178\u306e\u9664\u53bb\u3001OnGuard II Ag\u3001H \u3068\u306e\u4f75\u7528\u3092\u63a8\u5968<\/td>\n<td style=\"text-align: center\">\u25ef<\/td>\n<td style=\"text-align: center\"><\/td>\n<\/tr>\n<tr>\n<td>Ag\/H<\/td>\n<td>Ag\/H \u6a39\u8102\u306e2 \u5c64\u578b<\/td>\n<td>\u30cf\u30ed\u30b2\u30f3\u306e\u9664\u53bb<\/td>\n<td style=\"text-align: center\">\u25ef<\/td>\n<td style=\"text-align: center\"><\/td>\n<\/tr>\n<tr>\n<td>Ba\/Ag\/H<\/td>\n<td>Ba\/Ag\/H \u6a39\u8102\u306e3 \u5c64\u578b<\/td>\n<td>\u786b\u9178\u3068\u30cf\u30ed\u30b2\u30f3\u306e\u9664\u53bb<\/td>\n<td style=\"text-align: center\">\u25ef<\/td>\n<td style=\"text-align: center\"><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2>\u524d\u51e6\u7406\u306e\u969b\u306e\u6ce8\u610f\u70b9<\/h2>\n<p><strong>\u524d\u51e6\u7406\u306b\u3088\u3063\u3066\u4e0d\u7d14\u7269\u304c\u6df7\u5165\u3059\u308b\u3053\u3068\u304c\u3042\u308b\u305f\u3081\u3001\u64cd\u4f5c\u3092\u884c\u3046\u969b\u4ee5\u4e0b\u306e\u3053\u3068\u306b\u6ce8\u610f\u3057\u307e\u3059\u3002<\/strong>\u6c34\u306f\u3001\u6bd4\u62b5\u6297\u5024\u304c18 M\u03a9\u4ee5\u4e0a\u30670.22 \u03bcm\u306e\u308d\u904e\u819c\u3092\u901a\u3057\u305f\u7cbe\u88fd\u76f4\u5f8c\u306e\u8d85\u7d14\u6c34\u3092\u7528\u3044\u307e\u3059\u3002\u8a66\u85ac\u306f\u3001\u9ad8\u7d14\u5ea6\u306a\u8a66\u85ac\u3067\u3042\u308b\u7279\u7d1a\u8a66\u85ac\u306a\u3069\u3001\u30a4\u30aa\u30f3\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u7528\u3068\u3057\u3066\u8ca9\u58f2\u3055\u308c\u3066\u3044\u308b\u8a66\u85ac\u306e\u4f7f\u7528\u3092\u63a8\u5968\u3057\u307e\u3059\u3002\u524d\u51e6\u7406\u64cd\u4f5c\u306b\u3088\u3063\u3066\u30a4\u30aa\u30f3\u6210\u5206\u304c\u8a66\u6599\u4e2d\u306b\u6df7\u5165\u3057\u306a\u3044\u3088\u3046\u306b\u3001\u524d\u51e6\u7406\u64cd\u4f5c\u6642\u306b\u624b\u888b\u3092\u7740\u7528\u3057\u305f\u308a\u3001\u524d\u51e6\u7406\u306b\u7528\u3044\u305f\u5668\u5177\u985e\u3092\u8d85\u7d14\u6c34\u3067\u5341\u5206\u306b\u6d17\u6d44\u3059\u308b\u306a\u3069\u6ce8\u610f\u3057\u3066\u884c\u3044\u307e\u3059\u3002\u307e\u305f\u3001\u308d\u904e\u306b\u4f7f\u7528\u3059\u308b\u30d5\u30a3\u30eb\u30bf\u30fc\u3084\u524d\u51e6\u7406\u30ab\u30fc\u30c8\u30ea\u30c3\u30b8\u306a\u3069\u306b\u3082\u30a4\u30aa\u30f3\u304c\u6df7\u5165\u3059\u308b\u53ef\u80fd\u6027\u304c\u3042\u308b\u305f\u3081\u3001\u3042\u3089\u304b\u3058\u3081\u8d85\u7d14\u6c34\u306a\u3069\u3067\u6d17\u6d44\u3057\u3066\u304b\u3089\u4f7f\u7528\u3057\u307e\u3059\u3002<\/p>\n<p><strong>\u524d\u51e6\u7406\u306e\u59a5\u5f53\u6027\u3092\u6a19\u6e96\u6dfb\u52a0\u6642\u306e\u56de\u53ce\u7387\u3084\u3001\u540c\u3058\u8a66\u6599\u3092\u6570\u56de\u51e6\u7406\u3057\u305f\u3068\u304d\u306e\u518d\u73fe\u6027\u306a\u3069\u3067\u78ba\u8a8d\u3057\u307e\u3059\u3002\u307e\u305f\u3001\u524d\u51e6\u7406\u306b\u3088\u308b\u30a4\u30aa\u30f3\u306e\u6df7\u5165\u306e\u6709\u7121\u3092\u78ba\u8a8d\u3059\u308b\u305f\u3081\u306b\u3001\u5fc5\u305a\u30d6\u30e9\u30f3\u30af\u306e\u6e2c\u5b9a\u3092\u884c\u3063\u3066\u304f\u3060\u3055\u3044\u3002<\/strong><\/p>\n<h2>\u672a\u77e5\u8a66\u6599\u306e\u78ba\u8a8d<\/h2>\n<p><strong>\u8a66\u6599\u5185\u5bb9\u3092\u628a\u63e1\u3057\u3066\u3044\u308c\u3070\u524d\u51e6\u7406\u306e\u5fc5\u8981\u6027\u306e\u6709\u7121\u304c\u308f\u304b\u308a\u307e\u3059\u304c\u3001\u8a66\u6599\u306e\u60c5\u5831\u304c\u306a\u3044\u5834\u5408\u306f\u3001\u56f35\u306b\u793a\u3059\u30d5\u30ed\u30fc\u306b\u5f93\u3044\u8a66\u6599\u3092\u78ba\u8a8d\u3057\u306a\u304c\u3089\u524d\u51e6\u7406\u3092\u691c\u8a0e\u3057\u307e\u3059\u3002<\/strong>\u8a66\u6599\u306e\u8272\u3001\u900f\u660e\u5ea6\u3001\u81ed\u3044\u306a\u3069\u306e\u72b6\u614b\u304b\u3089\u5171\u5b58\u3059\u308b\u30de\u30c8\u30ea\u30c3\u30af\u30b9\u304c\u63a8\u6e2c\u3067\u304d\u3001\u307e\u305f\u6eb6\u96e2\u6db2\u3068\u6df7\u305c\u3066\u78ba\u8a8d\u3059\u308b\u3053\u3068\u306b\u3088\u3063\u3066\u3001\u8a66\u6599\u5c0e\u5165\u5f8c\u30b7\u30b9\u30c6\u30e0\u306e\u4e2d\u3067\u8d77\u3053\u308a\u3046\u308b\u3053\u3068\u304c\u4e88\u6e2c\u3067\u304d\u307e\u3059\u3002\u6700\u5584\u306a\u524d\u51e6\u7406\u306b\u3088\u3063\u3066\u9069\u5207\u306a\u6e2c\u5b9a\u304c\u5b9f\u73fe\u3067\u304d\u307e\u3059\u3002<\/p>\n<div id=\"attachment_1697\" style=\"width: 613px\" class=\"wp-caption aligncenter\"><a href=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/preprocessing-of-ion-chromatography-fig5.png\" rel=\"attachment wp-att-1697\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-1697\" class=\"size-full wp-image-1697\" src=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/preprocessing-of-ion-chromatography-fig5.png\" alt=\"preprocessing-of-ion-chromatography-fig5\" width=\"603\" height=\"887\" \/><\/a><p id=\"caption-attachment-1697\" class=\"wp-caption-text\">\u56f35 \u672a\u77e5\u8a66\u6599\u306e\u78ba\u8a8d<\/p><\/div>\n<h2>\u307e\u3068\u3081<\/h2>\n<p>\u30a4\u30aa\u30f3\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc\u3092\u7528\u3044\u305f\u30a4\u30aa\u30f3\u5206\u6790\u306f\u3001\u4e3b\u306b\u6c34\u6eb6\u6db2\u5316\u2192\u52a3\u5316\u30fb\u59a8\u5bb3\u6210\u5206\u306e\u9664\u53bb\u2192\u6fc3\u5ea6\u8abf\u6574\u306e\u30b9\u30c6\u30c3\u30d7\u306b\u3088\u308a\u524d\u51e6\u7406\u3092\u884c\u3044\u307e\u3059\u3002\u305d\u306e\u524d\u51e6\u7406\u65b9\u6cd5\u306e\u691c\u8a0e\u306b\u5f53\u305f\u3063\u3066\u306f\u3001\u8a66\u6599\u7d44\u6210\u306e\u628a\u63e1\u3001\u76ee\u7684\u6210\u5206\u306e\u660e\u78ba\u5316\u3001\u524d\u51e6\u7406\u306b\u3088\u308b\u5f71\u97ff\u306e\u4e88\u6e2c\u306a\u3069\u304c\u4e0d\u53ef\u6b20\u3067\u3059\u3002\u591a\u69d8\u306a\u8a66\u6599\u4e2d\u306e\u5206\u6790\u7a2e\u3092\u3088\u308a\u6b63\u78ba\u306b\u6e2c\u5b9a\u3059\u308b\u305f\u3081\u306b\u306f\u3001\u5206\u6790\u624b\u6cd5\u306b\u5408\u308f\u305b\u305f\u524d\u51e6\u7406\u306e\u78ba\u7acb\u306f\u3068\u3066\u3082\u91cd\u8981\u3067\u3059\u3002<\/p>\n<h2>\u3010\u7121\u6599\u30c0\u30a6\u30f3\u30ed\u30fc\u30c9\u3011\u30a4\u30aa\u30f3\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc\u304a\u5f79\u7acb\u3061\u8cc7\u6599\uff08\u57fa\u790e\u7de8\uff09<\/h2>\n<p>\u30a4\u30aa\u30f3\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u3092\u4f7f\u3044\u59cb\u3081\u3088\u3046\u3068\u8003\u3048\u3066\u3044\u308b\u3001\u5206\u96e2\u306e\u539f\u7406\u3084\u5206\u6790\u6642\u306e\u30dd\u30a4\u30f3\u30c8\u3092\u898b\u76f4\u3057\u305f\u3044\u3001\u30bd\u30d5\u30c8\u30a6\u30a7\u30a2\u306e\u6a5f\u80fd\u3092\u4f7f\u3044\u3053\u306a\u3057\u305f\u3044\u3001\u5177\u4f53\u7684\u306a\u5206\u6790\u4e8b\u4f8b\u3092\u77e5\u308a\u305f\u3044\u306a\u3069\u3002\u696d\u52d9\u306b\u3059\u3050\u306b\u5f79\u7acb\u3064\u30ce\u30a6\u30cf\u30a6\u304c\u8a70\u307e\u3063\u305f\u8cc7\u6599\u3092\u305c\u3072\u3001\u3054\u6d3b\u7528\u304f\u3060\u3055\u3044\u3002<\/p>\n<p><a class=\"btn btn-red\" href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/industrial\/chromatography\/ion-chromatography-ic\/dl-doc-basic.html?ICID=cmd_ic_r04_jp_preprocessing_of_ion_chromatography_Social_LAB\n\" target=\"_blank\" rel=\"noopener noreferrer\">\u7121\u6599\u30c0\u30a6\u30f3\u30ed\u30fc\u30c9\u306f\u3053\u3061\u3089<\/a><\/p>\n<h2>\u3010\u7121\u6599\u3011 e-learning \u30a4\u30aa\u30f3\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc\u57fa\u790e\u77e5\u8b58<\/h2>\n<p>\u30a4\u30aa\u30f3\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc\u306b\u3064\u3044\u3066\u3001\u3088\u308a\u6df1\u304f\u5b66\u3073\u305f\u3044\u65b9\u306f\u3001e-learning(\u30aa\u30f3\u30e9\u30a4\u30f3\u30bb\u30df\u30ca\u30fc)\u3092\u3054\u5229\u7528\u304f\u3060\u3055\u3044\u3002<\/p>\n<p>\u5206\u96e2\u3084\u691c\u51fa\u6cd5\u306a\u3069\u306e\u539f\u7406\u3092\u4e2d\u5fc3\u3068\u3057\u305f\u57fa\u790e\u306e\u89e3\u8aac\u3084\u3001\u5b9f\u969b\u306e\u5206\u6790\u6642\u306b\u6ce8\u610f\u3059\u308b\u30dd\u30a4\u30f3\u30c8\u307e\u3067\u3001\u696d\u52d9\u306b\u5f79\u7acb\u3064\u30d2\u30f3\u30c8\u304c\u5b66\u3079\u307e\u3059\u3002<\/p>\n<p><a class=\"btn btn-red\" href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/technical-resources\/e-learnings\/ic-dl.html?ICID=cmd_ic_r04_jp_preprocessing_of_ion_chromatography_Social_LAB\" target=\"_blank\" rel=\"noopener noreferrer\">\u8996\u8074\u306e\u304a\u7533\u3057\u8fbc\u307f\u306f\u3053\u3061\u3089<\/a><br \/>\n&nbsp;<\/p>\n<p>IC\u306b\u95a2\u3059\u308b\u30ea\u30bd\u30fc\u30b9<br \/>\n<a href=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/ion-chromatography-basic\/?ICID=cmd_ic_r04_jp_preprocessing_of_ion_chromatography_Social_LAB\" target=\"_blank\" rel=\"noopener\">\u30a4\u30aa\u30f3\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc\u3068\u306f\uff08IC\uff09\u3068\u306f<\/a><\/p>\n<p>&nbsp;<\/p>\n<p>\u7814\u7a76\u7528\u306b\u306e\u307f\u4f7f\u7528\u3067\u304d\u307e\u3059\u3002\u8a3a\u65ad\u7528\u306b\u306f\u4f7f\u7528\u3044\u305f\u3060\u3051\u307e\u305b\u3093\u3002<\/p>\n","protected":false},"excerpt":{"rendered":"<p>\u30a4\u30aa\u30f3\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc\uff08IC\uff09\u306f\u6c34\u6eb6\u6db2\u8a66\u6599\u4e2d\u306b\u542b\u307e\u308c\u308b\u30a4\u30aa\u30f3\u6210\u5206\u3092\u6e2c\u5b9a\u3057\u307e\u3059\u3002\u8a66\u6599\u304c\u56fa\u4f53\u3084\u6c17\u4f53\u306e\u5834\u5408\u3001\u307e\u305a\u8a66\u6599\u3092\u6c34\u6eb6\u6db2\u5316\u3059\u308b\u51e6\u7406\u304c\u5fc5\u8981\u3067\u3059\u3002\u4eca\u56de\u306f\u3001\u30a4\u30aa\u30f3\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc\u306b\u304a\u3051\u308b\u524d\u51e6\u7406\u306e\u65b9\u6cd5\u3001\u6ce8\u610f\u70b9\u306a\u3069\u306b\u3064\u3044\u3066\u3054\u7d39\u4ecb\u3057\u307e\u3059\u3002<\/p>\n","protected":false},"author":988,"featured_media":2981,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_monsterinsights_skip_tracking":false,"_genesis_hide_title":false,"_genesis_hide_breadcrumbs":false,"_genesis_hide_singular_image":false,"_genesis_hide_footer_widgets":false,"_genesis_custom_body_class":"","_genesis_custom_post_class":"","_genesis_layout":"","_jetpack_newsletter_access":"","_jetpack_dont_email_post_to_subs":false,"_jetpack_newsletter_tier_id":0,"_jetpack_memberships_contains_paywalled_content":false,"_jetpack_feature_clip_id":0,"_jetpack_memberships_contains_paid_content":false,"footnotes":"","jetpack_post_was_ever_published":false},"categories":[157],"tags":[52],"division":[],"class_list":{"0":"post-587","1":"post","2":"type-post","3":"status-publish","4":"format-standard","5":"has-post-thumbnail","7":"category-analysis","8":"tag-ion-chromatography","9":"entry"},"_selected_authors":"","_selected_reviewers":"","acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v27.8 (Yoast SEO v27.8) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>\u6b63\u78ba\u306a\u6e2c\u5b9a\u306e\u305f\u3081\u306b\uff01\u30a4\u30aa\u30f3\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc\u306b\u304a\u3051\u308b\u8a66\u6599\u306e\u524d\u51e6\u7406\u65b9\u6cd5\u3068\u6ce8\u610f\u70b9 - Learning at the Bench<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/preprocessing-of-ion-chromatography\/\" \/>\n<meta property=\"og:locale\" content=\"ja_JP\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"\u6b63\u78ba\u306a\u6e2c\u5b9a\u306e\u305f\u3081\u306b\uff01\u30a4\u30aa\u30f3\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc\u306b\u304a\u3051\u308b\u8a66\u6599\u306e\u524d\u51e6\u7406\u65b9\u6cd5\u3068\u6ce8\u610f\u70b9\" \/>\n<meta property=\"og:description\" content=\"\u30a4\u30aa\u30f3\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc\uff08IC\uff09\u306f\u6c34\u6eb6\u6db2\u8a66\u6599\u4e2d\u306b\u542b\u307e\u308c\u308b\u30a4\u30aa\u30f3\u6210\u5206\u3092\u6e2c\u5b9a\u3057\u307e\u3059\u3002\u8a66\u6599\u304c\u56fa\u4f53\u3084\u6c17\u4f53\u306e\u5834\u5408\u3001\u307e\u305a\u8a66\u6599\u3092\u6c34\u6eb6\u6db2\u5316\u3059\u308b\u51e6\u7406\u304c\u5fc5\u8981\u3067\u3059\u3002\u4eca\u56de\u306f\u3001\u30a4\u30aa\u30f3\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc\u306b\u304a\u3051\u308b\u524d\u51e6\u7406\u306e\u65b9\u6cd5\u3001\u6ce8\u610f\u70b9\u306a\u3069\u306b\u3064\u3044\u3066\u3054\u7d39\u4ecb\u3057\u307e\u3059\u3002\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/preprocessing-of-ion-chromatography\/\" \/>\n<meta property=\"og:site_name\" content=\"Learning at the Bench\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/ThermoFisherJapan\" \/>\n<meta property=\"article:published_time\" content=\"2017-02-09T00:00:00+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2023-08-17T06:12:37+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/preprocessing-of-ion-chromatography-title.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"1200\" \/>\n\t<meta property=\"og:image:height\" content=\"631\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"LATB Staff\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:creator\" content=\"@ThermoFisherJP\" \/>\n<meta name=\"twitter:site\" content=\"@ThermoFisherJP\" \/>\n<meta name=\"twitter:label1\" content=\"\u57f7\u7b46\u8005\" \/>\n\t<meta name=\"twitter:data1\" content=\"LATB Staff\" \/>\n\t<meta name=\"twitter:label2\" content=\"\u63a8\u5b9a\u8aad\u307f\u53d6\u308a\u6642\u9593\" \/>\n\t<meta name=\"twitter:data2\" content=\"20\u5206\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/preprocessing-of-ion-chromatography\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/preprocessing-of-ion-chromatography\\\/\"},\"author\":{\"name\":\"LATB Staff\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#\\\/schema\\\/person\\\/00a095a01d54afcdf9457465feb04f7d\"},\"headline\":\"\u6b63\u78ba\u306a\u6e2c\u5b9a\u306e\u305f\u3081\u306b\uff01\u30a4\u30aa\u30f3\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc\u306b\u304a\u3051\u308b\u8a66\u6599\u306e\u524d\u51e6\u7406\u65b9\u6cd5\u3068\u6ce8\u610f\u70b9\",\"datePublished\":\"2017-02-09T00:00:00+00:00\",\"dateModified\":\"2023-08-17T06:12:37+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/preprocessing-of-ion-chromatography\\\/\"},\"wordCount\":139,\"commentCount\":0,\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/preprocessing-of-ion-chromatography\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2019\\\/07\\\/preprocessing-of-ion-chromatography-title.jpg\",\"keywords\":[\"\u30a4\u30aa\u30f3\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc\"],\"articleSection\":[\"\u5206\u6790\u30fb\u6e2c\u5b9a\u95a2\u9023\"],\"inLanguage\":\"ja\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/preprocessing-of-ion-chromatography\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/preprocessing-of-ion-chromatography\\\/\",\"url\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/preprocessing-of-ion-chromatography\\\/\",\"name\":\"\u6b63\u78ba\u306a\u6e2c\u5b9a\u306e\u305f\u3081\u306b\uff01\u30a4\u30aa\u30f3\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc\u306b\u304a\u3051\u308b\u8a66\u6599\u306e\u524d\u51e6\u7406\u65b9\u6cd5\u3068\u6ce8\u610f\u70b9 - Learning at the Bench\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/preprocessing-of-ion-chromatography\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/preprocessing-of-ion-chromatography\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2019\\\/07\\\/preprocessing-of-ion-chromatography-title.jpg\",\"datePublished\":\"2017-02-09T00:00:00+00:00\",\"dateModified\":\"2023-08-17T06:12:37+00:00\",\"author\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#\\\/schema\\\/person\\\/00a095a01d54afcdf9457465feb04f7d\"},\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/preprocessing-of-ion-chromatography\\\/#breadcrumb\"},\"inLanguage\":\"ja\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/preprocessing-of-ion-chromatography\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"ja\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/preprocessing-of-ion-chromatography\\\/#primaryimage\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2019\\\/07\\\/preprocessing-of-ion-chromatography-title.jpg\",\"contentUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2019\\\/07\\\/preprocessing-of-ion-chromatography-title.jpg\",\"width\":1200,\"height\":631,\"caption\":\"preprocessing-of-ion-chromatography-title\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/preprocessing-of-ion-chromatography\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"\u6b63\u78ba\u306a\u6e2c\u5b9a\u306e\u305f\u3081\u306b\uff01\u30a4\u30aa\u30f3\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc\u306b\u304a\u3051\u308b\u8a66\u6599\u306e\u524d\u51e6\u7406\u65b9\u6cd5\u3068\u6ce8\u610f\u70b9\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#website\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/\",\"name\":\"Learning at the Bench\",\"description\":\"\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"ja\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#\\\/schema\\\/person\\\/00a095a01d54afcdf9457465feb04f7d\",\"name\":\"LATB Staff\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"ja\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/8803277856c8b753feb4217dff0f9953327452df1a615c3c88b2f9864efb2ddd?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/8803277856c8b753feb4217dff0f9953327452df1a615c3c88b2f9864efb2ddd?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/8803277856c8b753feb4217dff0f9953327452df1a615c3c88b2f9864efb2ddd?s=96&d=mm&r=g\",\"caption\":\"LATB Staff\"},\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/author\\\/latbstaff\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"\u6b63\u78ba\u306a\u6e2c\u5b9a\u306e\u305f\u3081\u306b\uff01\u30a4\u30aa\u30f3\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc\u306b\u304a\u3051\u308b\u8a66\u6599\u306e\u524d\u51e6\u7406\u65b9\u6cd5\u3068\u6ce8\u610f\u70b9 - Learning at the Bench","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/preprocessing-of-ion-chromatography\/","og_locale":"ja_JP","og_type":"article","og_title":"\u6b63\u78ba\u306a\u6e2c\u5b9a\u306e\u305f\u3081\u306b\uff01\u30a4\u30aa\u30f3\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc\u306b\u304a\u3051\u308b\u8a66\u6599\u306e\u524d\u51e6\u7406\u65b9\u6cd5\u3068\u6ce8\u610f\u70b9","og_description":"\u30a4\u30aa\u30f3\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc\uff08IC\uff09\u306f\u6c34\u6eb6\u6db2\u8a66\u6599\u4e2d\u306b\u542b\u307e\u308c\u308b\u30a4\u30aa\u30f3\u6210\u5206\u3092\u6e2c\u5b9a\u3057\u307e\u3059\u3002\u8a66\u6599\u304c\u56fa\u4f53\u3084\u6c17\u4f53\u306e\u5834\u5408\u3001\u307e\u305a\u8a66\u6599\u3092\u6c34\u6eb6\u6db2\u5316\u3059\u308b\u51e6\u7406\u304c\u5fc5\u8981\u3067\u3059\u3002\u4eca\u56de\u306f\u3001\u30a4\u30aa\u30f3\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc\u306b\u304a\u3051\u308b\u524d\u51e6\u7406\u306e\u65b9\u6cd5\u3001\u6ce8\u610f\u70b9\u306a\u3069\u306b\u3064\u3044\u3066\u3054\u7d39\u4ecb\u3057\u307e\u3059\u3002","og_url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/preprocessing-of-ion-chromatography\/","og_site_name":"Learning at the Bench","article_publisher":"https:\/\/www.facebook.com\/ThermoFisherJapan","article_published_time":"2017-02-09T00:00:00+00:00","article_modified_time":"2023-08-17T06:12:37+00:00","og_image":[{"width":1200,"height":631,"url":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/preprocessing-of-ion-chromatography-title.jpg","type":"image\/jpeg"}],"author":"LATB Staff","twitter_card":"summary_large_image","twitter_creator":"@ThermoFisherJP","twitter_site":"@ThermoFisherJP","twitter_misc":{"\u57f7\u7b46\u8005":"LATB Staff","\u63a8\u5b9a\u8aad\u307f\u53d6\u308a\u6642\u9593":"20\u5206"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/preprocessing-of-ion-chromatography\/#article","isPartOf":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/preprocessing-of-ion-chromatography\/"},"author":{"name":"LATB Staff","@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#\/schema\/person\/00a095a01d54afcdf9457465feb04f7d"},"headline":"\u6b63\u78ba\u306a\u6e2c\u5b9a\u306e\u305f\u3081\u306b\uff01\u30a4\u30aa\u30f3\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc\u306b\u304a\u3051\u308b\u8a66\u6599\u306e\u524d\u51e6\u7406\u65b9\u6cd5\u3068\u6ce8\u610f\u70b9","datePublished":"2017-02-09T00:00:00+00:00","dateModified":"2023-08-17T06:12:37+00:00","mainEntityOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/preprocessing-of-ion-chromatography\/"},"wordCount":139,"commentCount":0,"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/preprocessing-of-ion-chromatography\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/preprocessing-of-ion-chromatography-title.jpg","keywords":["\u30a4\u30aa\u30f3\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc"],"articleSection":["\u5206\u6790\u30fb\u6e2c\u5b9a\u95a2\u9023"],"inLanguage":"ja","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/preprocessing-of-ion-chromatography\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/preprocessing-of-ion-chromatography\/","url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/preprocessing-of-ion-chromatography\/","name":"\u6b63\u78ba\u306a\u6e2c\u5b9a\u306e\u305f\u3081\u306b\uff01\u30a4\u30aa\u30f3\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc\u306b\u304a\u3051\u308b\u8a66\u6599\u306e\u524d\u51e6\u7406\u65b9\u6cd5\u3068\u6ce8\u610f\u70b9 - Learning at the Bench","isPartOf":{"@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/preprocessing-of-ion-chromatography\/#primaryimage"},"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/preprocessing-of-ion-chromatography\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/preprocessing-of-ion-chromatography-title.jpg","datePublished":"2017-02-09T00:00:00+00:00","dateModified":"2023-08-17T06:12:37+00:00","author":{"@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#\/schema\/person\/00a095a01d54afcdf9457465feb04f7d"},"breadcrumb":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/preprocessing-of-ion-chromatography\/#breadcrumb"},"inLanguage":"ja","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/preprocessing-of-ion-chromatography\/"]}]},{"@type":"ImageObject","inLanguage":"ja","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/preprocessing-of-ion-chromatography\/#primaryimage","url":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/preprocessing-of-ion-chromatography-title.jpg","contentUrl":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/preprocessing-of-ion-chromatography-title.jpg","width":1200,"height":631,"caption":"preprocessing-of-ion-chromatography-title"},{"@type":"BreadcrumbList","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/preprocessing-of-ion-chromatography\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/"},{"@type":"ListItem","position":2,"name":"\u6b63\u78ba\u306a\u6e2c\u5b9a\u306e\u305f\u3081\u306b\uff01\u30a4\u30aa\u30f3\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc\u306b\u304a\u3051\u308b\u8a66\u6599\u306e\u524d\u51e6\u7406\u65b9\u6cd5\u3068\u6ce8\u610f\u70b9"}]},{"@type":"WebSite","@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#website","url":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/","name":"Learning at the Bench","description":"","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"ja"},{"@type":"Person","@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#\/schema\/person\/00a095a01d54afcdf9457465feb04f7d","name":"LATB Staff","image":{"@type":"ImageObject","inLanguage":"ja","@id":"https:\/\/secure.gravatar.com\/avatar\/8803277856c8b753feb4217dff0f9953327452df1a615c3c88b2f9864efb2ddd?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/8803277856c8b753feb4217dff0f9953327452df1a615c3c88b2f9864efb2ddd?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/8803277856c8b753feb4217dff0f9953327452df1a615c3c88b2f9864efb2ddd?s=96&d=mm&r=g","caption":"LATB Staff"},"url":"https:\/\/admin.acceleratingscience.com\/author\/latbstaff\/"}]}},"taxonomy_info":{"category":[{"value":157,"label":"\u5206\u6790\u30fb\u6e2c\u5b9a\u95a2\u9023"}],"post_tag":[{"value":52,"label":"\u30a4\u30aa\u30f3\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc"}]},"featured_image_src_large":["https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/preprocessing-of-ion-chromatography-title-1024x538.jpg",760,399,true],"author_info":{"display_name":"LATB Staff","author_link":"https:\/\/admin.acceleratingscience.com\/author\/latbstaff\/"},"comment_info":0,"category_info":[{"term_id":157,"name":"\u5206\u6790\u30fb\u6e2c\u5b9a\u95a2\u9023","slug":"analysis","term_group":0,"term_taxonomy_id":157,"taxonomy":"category","description":"","parent":0,"count":105,"filter":"raw","meta":[],"cat_ID":157,"category_count":105,"category_description":"","cat_name":"\u5206\u6790\u30fb\u6e2c\u5b9a\u95a2\u9023","category_nicename":"analysis","category_parent":0}],"tag_info":[{"term_id":52,"name":"\u30a4\u30aa\u30f3\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc","slug":"ion-chromatography","term_group":0,"term_taxonomy_id":52,"taxonomy":"post_tag","description":"","parent":0,"count":12,"filter":"raw","meta":[]}],"jetpack-related-posts":[{"id":25090,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/battery-development-elemental-analysis-csm-26016\/","url_meta":{"origin":587,"position":0},"title":"\u30ea\u30c1\u30a6\u30e0\u30a4\u30aa\u30f3\u96fb\u6c60\u88fd\u9020\uff1a\u4f7f\u7528\u3055\u308c\u308b\u5316\u5b66\u5206\u6790\u6280\u8853","author":"LatB Staff","date":"2026\u5e744\u670820\u65e5","format":false,"excerpt":"\u9ad8\u6027\u80fd\u96fb\u6c60\u306b\u5bfe\u3059\u308b\u9700\u8981\u306e\u6025\u5897\u306f\u3001\u751f\u7523\u306e\u3042\u3089\u3086\u308b\u6bb5\u968e\u306b\u304a\u3051\u308b\u5927\u898f\u6a21\u306a\u6295\u8cc7\u3092\u4fc3\u3057\u3066\u3044\u307e\u3059\u3002\u96fb\u6c60\u7814\u7a76\u304a\u3088\u3073\u2026","rel":"","context":"\u5206\u6790\u30fb\u6e2c\u5b9a\u95a2\u9023","block_context":{"text":"\u5206\u6790\u30fb\u6e2c\u5b9a\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/analysis\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/04\/battery-development-elemental-analysis-csm-26016_eyecatch.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/04\/battery-development-elemental-analysis-csm-26016_eyecatch.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/04\/battery-development-elemental-analysis-csm-26016_eyecatch.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/04\/battery-development-elemental-analysis-csm-26016_eyecatch.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/04\/battery-development-elemental-analysis-csm-26016_eyecatch.jpg?resize=1050%2C600&ssl=1 3x"},"classes":[]},{"id":25592,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/ion-chromatography-contaminant-analysis-cmd-26024\/","url_meta":{"origin":587,"position":1},"title":"\u5316\u7ca7\u54c1\u4e2d\u306ePFAS\u5206\u6790\u3068\u306f\uff1f\u7dcf\u6709\u6a5f\u30d5\u30c3\u7d20\uff08TOF\uff09\u6e2c\u5b9a\u306b\u3088\u308b\u30b9\u30af\u30ea\u30fc\u30cb\u30f3\u30b0\u3068\u898f\u5236\u5bfe\u5fdc","author":"LatB Staff","date":"2026\u5e749\u670810\u65e5","format":false,"excerpt":"PFAS\uff08\u6709\u6a5f\u30d5\u30c3\u7d20\u5316\u5408\u7269\uff09\u306f\u3001\u300c\u6c38\u9060\u306e\u5316\u5b66\u7269\u8cea\uff08Forever Chemicals\uff09\u300d\u3068\u3082\u547c\u3070\u308c\u3001\u2026","rel":"","context":"\u5206\u6790\u30fb\u6e2c\u5b9a\u95a2\u9023","block_context":{"text":"\u5206\u6790\u30fb\u6e2c\u5b9a\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/analysis\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/08\/ion-chromatography-contaminant-analysis-cmd-26024_eyecatch.png?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/08\/ion-chromatography-contaminant-analysis-cmd-26024_eyecatch.png?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/08\/ion-chromatography-contaminant-analysis-cmd-26024_eyecatch.png?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/08\/ion-chromatography-contaminant-analysis-cmd-26024_eyecatch.png?resize=700%2C400&ssl=1 2x"},"classes":[]},{"id":25362,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/battery-development-ion-chromatography-csm-26020\/","url_meta":{"origin":587,"position":2},"title":"IC-MS\/MS\u3092\u7528\u3044\u305f\u30ea\u30c1\u30a6\u30e0\u30a4\u30aa\u30f3\u96fb\u6c60\u8ca0\u6975\u306e\u52a3\u5316\u89e3\u6790","author":"LatB Staff","date":"2026\u5e746\u670826\u65e5","format":false,"excerpt":"\u539f\u6587\uff08\u82f1\u8a9e\uff09\uff1aExploring Lithium-Ion Battery Anode Degrada\u2026","rel":"","context":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","block_context":{"text":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/mol-bio\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/06\/battery-development-ion-chromatography-csm-26020_eyecatch.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/06\/battery-development-ion-chromatography-csm-26020_eyecatch.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/06\/battery-development-ion-chromatography-csm-26020_eyecatch.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/06\/battery-development-ion-chromatography-csm-26020_eyecatch.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/06\/battery-development-ion-chromatography-csm-26020_eyecatch.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/06\/battery-development-ion-chromatography-csm-26020_eyecatch.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":24614,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/battery-manufacturing-elemental-analysis-csm-26005\/","url_meta":{"origin":587,"position":3},"title":"\u96fb\u6c60\u30ea\u30b5\u30a4\u30af\u30eb\u306b\u304a\u3051\u308b\u5143\u7d20\u5206\u6790","author":"LatB Staff","date":"2026\u5e741\u670827\u65e5","format":false,"excerpt":"\u81ea\u52d5\u8eca\u306e\u96fb\u52d5\u5316\u3068\u518d\u751f\u53ef\u80fd\u30a8\u30cd\u30eb\u30ae\u30fc\u306e\u8caf\u8535\u80fd\u529b\u306e\u5897\u52a0\u306f\u3001\u3068\u3082\u306b\u96fb\u6c60\u306b\u5bfe\u3059\u308b\u9700\u8981\u306e\u5927\u5e45\u306a\u52a0\u901f\u3092\u3082\u305f\u3089\u3057\u3066\u2026","rel":"","context":"\u5206\u6790\u30fb\u6e2c\u5b9a\u95a2\u9023","block_context":{"text":"\u5206\u6790\u30fb\u6e2c\u5b9a\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/analysis\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/01\/battery-manufacturing-elemental-analysis-csm-26005_eyecatch.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/01\/battery-manufacturing-elemental-analysis-csm-26005_eyecatch.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/01\/battery-manufacturing-elemental-analysis-csm-26005_eyecatch.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/01\/battery-manufacturing-elemental-analysis-csm-26005_eyecatch.jpg?resize=700%2C400&ssl=1 2x"},"classes":[]},{"id":24408,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/elemental-analysis-case-introduction-cmd-25076\/","url_meta":{"origin":587,"position":4},"title":"LA-ICP-MS\u3067\u5b9f\u73fe\u3059\u308b\u7c89\u672b\u8a66\u6599\u306e\u8fc5\u901f\u30fb\u9ad8\u611f\u5ea6\u306a\u5143\u7d20\u5206\u6790","author":"LatB Staff","date":"2025\u5e7412\u670812\u65e5","format":false,"excerpt":"\u5316\u5b66\u54c1\u3084\u5de5\u696d\u6750\u6599\u306e\u539f\u6599\u3001\u304a\u3088\u3073\u4e8c\u6b21\u96fb\u6c60\u5411\u3051\u306e\u6a5f\u80fd\u6027\u6750\u6599\u306a\u3069\u3001\u7c89\u672b\u8a66\u6599\u3084\u30bb\u30e9\u30df\u30c3\u30af\u30b9\u6750\u6599\u4e2d\u306e\u5fae\u91cf\u5143\u7d20\u306e\u2026","rel":"","context":"\u5206\u6790\u30fb\u6e2c\u5b9a\u95a2\u9023","block_context":{"text":"\u5206\u6790\u30fb\u6e2c\u5b9a\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/analysis\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/12\/shutterstock_2249094135-scaled.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/12\/shutterstock_2249094135-scaled.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/12\/shutterstock_2249094135-scaled.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/12\/shutterstock_2249094135-scaled.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/12\/shutterstock_2249094135-scaled.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/12\/shutterstock_2249094135-scaled.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":25673,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/ion-chromatography-semiconductors-cmd-26028\/","url_meta":{"origin":587,"position":5},"title":"\u534a\u5c0e\u4f53\u88fd\u9020\u306b\u304a\u3051\u308bIC\u306e\u5f79\u5272","author":"LatB Staff","date":"2026\u5e7410\u67082\u65e5","format":false,"excerpt":"\u30b9\u30de\u30fc\u30c8\u30d5\u30a9\u30f3\u3084AI\u30b5\u30fc\u30d0\u30fc\u3001\u81ea\u52d5\u8eca\u306a\u3069\u3001\u79c1\u305f\u3061\u306e\u8eab\u306e\u56de\u308a\u306b\u3042\u308b\u96fb\u5b50\u6a5f\u5668\u306e\u591a\u304f\u306f\u534a\u5c0e\u4f53\u306b\u3088\u3063\u3066\u652f\u3048\u3089\u2026","rel":"","context":"\u5206\u6790\u30fb\u6e2c\u5b9a\u95a2\u9023","block_context":{"text":"\u5206\u6790\u30fb\u6e2c\u5b9a\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/analysis\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/09\/ion-chromatography-semiconductors-cmd-26028_eyecatch.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/09\/ion-chromatography-semiconductors-cmd-26028_eyecatch.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/09\/ion-chromatography-semiconductors-cmd-26028_eyecatch.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/09\/ion-chromatography-semiconductors-cmd-26028_eyecatch.jpg?resize=700%2C400&ssl=1 2x"},"classes":[]}],"jetpack_sharing_enabled":true,"amp_enabled":true,"jetpack_featured_media_url":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/preprocessing-of-ion-chromatography-title.jpg","_links":{"self":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/posts\/587","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/users\/988"}],"replies":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/comments?post=587"}],"version-history":[{"count":0,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/posts\/587\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/media\/2981"}],"wp:attachment":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/media?parent=587"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/categories?post=587"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/tags?post=587"},{"taxonomy":"division","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/division?post=587"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}