{"id":594,"date":"2017-02-07T00:00:00","date_gmt":"2017-02-07T00:00:00","guid":{"rendered":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/about-clariom-d\/"},"modified":"2021-12-14T14:31:45","modified_gmt":"2021-12-14T05:31:45","slug":"about-clariom-d","status":"publish","type":"post","link":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/about-clariom-d\/","title":{"rendered":"\u6b21\u4e16\u4ee3\u578b\u8d85\u9ad8\u5bc6\u5ea6\u30de\u30a4\u30af\u30ed\u30a2\u30ec\u30a4 Clariom D \u306e\u5727\u5012\u7684\u306a\u89e3\u6790\u6027\u80fd\u3068\u306f\uff1f"},"content":{"rendered":"<h2>\u306f\u3058\u3081\u306b<\/h2>\n<p>\u5f0a\u793e\u306e\u6b21\u4e16\u4ee3\u578b\u767a\u73fe\u89e3\u6790\u30de\u30a4\u30af\u30ed\u30a2\u30ec\u30a4\u300c<a href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/life-science\/microarray-analysis\/transcriptome-profiling-microarrays\/clariom-assays.html?CID=gsd_mic_gex_r04_jp_cp0000_pjt0000_gsd00000_0so_blg_op_awa_oc_s00_ma1_Social_LAB\" target=\"_blank\" rel=\"noopener noreferrer\">Clariom D<\/a>\u300d\u306f\u3001\u7dcf\u30d7\u30ed\u30fc\u30d6\u6570600\u4e07\u4ee5\u4e0a\u3092\u8a87\u308b\u8d85\u9ad8\u5bc6\u5ea6\u306e\u591a\u6a5f\u80fd\u30de\u30a4\u30af\u30ed\u30a2\u30ec\u30a4\u3067\u3042\u308a\u3001\u5f0a\u793e\u306e\u767a\u73fe\u89e3\u6790\u88fd\u54c1\u306e\u4e2d\u3067\u307e\u3055\u306b\u30d5\u30e9\u30c3\u30b0\u30b7\u30c3\u30d7\u3068\u547c\u3076\u306b\u3075\u3055\u308f\u3057\u3044\u30e2\u30c7\u30eb\u3068\u306a\u3063\u3066\u3044\u307e\u3059\u3002<strong><a href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/life-science\/microarray-analysis\/transcriptome-profiling-microarrays\/clariom-assays.html?CID=gsd_mic_gex_r04_jp_cp0000_pjt0000_gsd00000_0so_blg_op_awa_oc_s00_ma1_Social_LAB\" target=\"_blank\" rel=\"noopener noreferrer\">Clariom D<\/a>\u306f\u5f93\u6765\u306e\u767a\u73fe\u89e3\u6790\u306b\u52a0\u3048\u3001\u9078\u629e\u7684\u30b9\u30d7\u30e9\u30a4\u30b7\u30f3\u30b0\u89e3\u6790\u3084long non-coding RNA (lncRNA) \u89e3\u6790\u306a\u3069\u3001\u30c8\u30e9\u30f3\u30b9\u30af\u30ea\u30d7\u30c8\u30fc\u30e0\u30ec\u30d9\u30eb\u3067\u306e\u89e3\u6790\u306b\u3082\u5a01\u529b\u3092\u767a\u63ee\u3057\u307e\u3059\u3002<\/strong>\u3053\u3053\u3067\u306f<a href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/life-science\/microarray-analysis\/transcriptome-profiling-microarrays\/clariom-assays.html?CID=gsd_mic_gex_r04_jp_cp0000_pjt0000_gsd00000_0so_blg_op_awa_oc_s00_ma1_Social_LAB\" target=\"_blank\" rel=\"noopener noreferrer\">Clariom D<\/a>\u306e\u5727\u5012\u7684\u306a\u89e3\u6790\u6027\u80fd\u306b\u3064\u3044\u3066\u307e\u3068\u3081\u3066\u307f\u307e\u3057\u305f\u3002<\/p>\n<h2>\u5727\u5012\u7684\u306a\u30d7\u30ed\u30fc\u30d6\u6570\u3067\u8ee2\u5199\u9818\u57df\u3092\u30ab\u30d0\u30fc<\/h2>\n<p><a href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/life-science\/microarray-analysis\/transcriptome-profiling-microarrays\/clariom-assays.html?CID=gsd_mic_gex_r04_jp_cp0000_pjt0000_gsd00000_0so_blg_op_awa_oc_s00_ma1_Social_LAB\" target=\"_blank\" rel=\"noopener noreferrer\">Clariom D<\/a>\u306e\u6027\u80fd\u3092\u8a9e\u308b\u4e0a\u3067\u6b20\u304b\u3059\u3053\u3068\u306e\u3067\u304d\u306a\u3044\u306e\u304c\u3001\u305d\u306e\u30d7\u30ed\u30fc\u30d6\u6570\u3067\u3057\u3087\u3046\u3002<strong>600\u4e07\u3092\u8d85\u3048\u308b\u30d7\u30ed\u30fc\u30d6\u304c\u907a\u4f1d\u5b50\u767a\u73fe\u9818\u57df\u3092\u5e83\u7bc4\u56f2\u306b\u308f\u305f\u308a\u30ab\u30d0\u30fc\u3057\u307e\u3059\u3002<\/strong>\u4e0b\u56f3\u306f<a href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/life-science\/microarray-analysis\/transcriptome-profiling-microarrays\/clariom-assays.html?CID=gsd_mic_gex_r04_jp_cp0000_pjt0000_gsd00000_0so_blg_op_awa_oc_s00_ma1_Social_LAB\" target=\"_blank\" rel=\"noopener noreferrer\">Clariom D<\/a>\u306b\u642d\u8f09\u3055\u308c\u305f\u5404\u30d7\u30ed\u30fc\u30d6\u304c\u907a\u4f1d\u5b50\u306e\u3069\u306e\u914d\u5217\u306b\u5bfe\u5fdc\u3057\u3066\u3044\u308b\u304b\u3092\u793a\u3057\u305f\u3082\u306e\u3067\u3059\u3002<\/p>\n<div id=\"attachment_1704\" style=\"width: 1034px\" class=\"wp-caption aligncenter\"><a href=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/about-clariom-d-fig1.png\" rel=\"attachment wp-att-1704\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-1704\" class=\"size-full wp-image-1704\" src=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/about-clariom-d-fig1.png\" alt=\"about-clariom-d-fig1\" width=\"1024\" height=\"691\" \/><\/a><p id=\"caption-attachment-1704\" class=\"wp-caption-text\">\u56f31 COLCA2 (Colorectal Cancer Associated 2) \u907a\u4f1d\u5b50\u306e\u30a8\u30af\u30bd\u30f3\u30fb\u30a4\u30f3\u30c8\u30ed\u30f3\u69cb\u9020\u3068\u30d7\u30ed\u30fc\u30d6\u306e\u4f4d\u7f6e\u95a2\u4fc2\u306e\u6a21\u5f0f\u56f3<\/p><\/div>\n<p>\u4e0a\u56f3\u306fCOLCA2 (Colorectal Cancer Associated 2) \u907a\u4f1d\u5b50\u306e\u30a8\u30af\u30bd\u30f3\u30fb\u30a4\u30f3\u30c8\u30ed\u30f3\u69cb\u9020\u3068\u30d7\u30ed\u30fc\u30d6\u306e\u4f4d\u7f6e\u95a2\u4fc2\u3092\u6a21\u5f0f\u7684\u306b\u793a\u3057\u305f\u3082\u306e\u3067\u3059\u3002\u3053\u306e\u56f3\u306e\u8d64\u3044\u67a0\u7dda\u3067\u56f2\u307e\u308c\u305f\u90e8\u5206\u304c\u30a8\u30af\u30bd\u30f3\u90e8\u5206\u306b\u5bfe\u5fdc\u3057\u3066\u3044\u308b\u30d7\u30ed\u30fc\u30d6\u7fa4\u3067\u3059\u3002<strong>\u3053\u306e\u56f3\u304b\u3089\u5206\u304b\u308b\u3088\u3046\u306b\u3001<a href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/life-science\/microarray-analysis\/transcriptome-profiling-microarrays\/clariom-assays.html?CID=gsd_mic_gex_r04_jp_cp0000_pjt0000_gsd00000_0so_blg_op_awa_oc_s00_ma1_Social_LAB\" target=\"_blank\" rel=\"noopener noreferrer\">Clariom D<\/a>\u306e\u30d7\u30ed\u30fc\u30d6\u306f\u907a\u4f1d\u5b50\u5168\u4f53\u306b\u308f\u305f\u3063\u3066\u307b\u307c\u5168\u3066\u306e\u30a8\u30af\u30bd\u30f3\u306b\u5bfe\u5fdc\u3059\u308b\u3088\u3046\u306b\u8a2d\u8a08\u3055\u308c\u3066\u3044\u307e\u3059\u3002<\/strong>\u307e\u305f\u4e0a\u56f3\u306e\u30b0\u30ec\u30fc\u306e\u7dda\u3067\u56f2\u307e\u308c\u305f\u90e8\u5206\u306f\u3001\u30a8\u30af\u30bd\u30f3\u3068\u30a8\u30af\u30bd\u30f3\u306e\u63a5\u5408\u90e8\u3001\u3044\u308f\u3086\u308b\u30a8\u30af\u30bd\u30f3\u30b8\u30e3\u30f3\u30af\u30b7\u30e7\u30f3\u90e8\u306b\u8a2d\u8a08\u3055\u308c\u305f\u30d7\u30ed\u30fc\u30d6\u3067\u3059\u3002\u3053\u306e\u30d7\u30ed\u30fc\u30d6\u306b\u3088\u308a\u3001\u9078\u629e\u7684\u30b9\u30d7\u30e9\u30a4\u30b7\u30f3\u30b0\u306e\u89e3\u6790\u7cbe\u5ea6\u304c\u4e0a\u304c\u308a\u307e\u3059\u3002<\/p>\n<p>\u3053\u306e\u3088\u3046\u306b<strong><a href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/life-science\/microarray-analysis\/transcriptome-profiling-microarrays\/clariom-assays.html?CID=gsd_mic_gex_r04_jp_cp0000_pjt0000_gsd00000_0so_blg_op_awa_oc_s00_ma1_Social_LAB\" target=\"_blank\" rel=\"noopener noreferrer\">Clariom D<\/a>\u3067\u306f\u4e00\u3064\u306e\u907a\u4f1d\u5b50\u306b\u5bfe\u3057\u3066\u6570\u5341\u3082\u306e\u30d7\u30ed\u30fc\u30d6\u304c\u8a2d\u8a08\u3055\u308c\u3066\u3044\u308b\u305f\u3081\u3001\u5358\u306a\u308b\u907a\u4f1d\u5b50\u30ec\u30d9\u30eb\u306e\u767a\u73fe\u89e3\u6790\u3060\u3051\u306b\u3068\u3069\u307e\u3089\u306a\u3044\u3001\u30c8\u30e9\u30f3\u30b9\u30af\u30ea\u30d7\u30c8\u30fc\u30e0\u30ec\u30d9\u30eb\u306b\u3088\u308b\u89e3\u6790\u304c\u53ef\u80fd\u3068\u306a\u3063\u3066\u3044\u308b\u306e\u3067\u3059\u3002<\/strong><\/p>\n<p>\u3061\u306a\u307f\u306b\u3001\u5f0a\u793e\u4ee5\u5916\u306e\u30de\u30a4\u30af\u30ed\u30a2\u30ec\u30a4\u3067\u306f\u591a\u304f\u306e\u5834\u5408\u30011\u907a\u4f1d\u5b50\u3092\u305f\u3063\u305f\u4e00\u3064\u306e\u30d7\u30ed\u30fc\u30d6\u3067\u89e3\u6790\u3057\u3066\u3044\u307e\u3059\u3002\u305f\u3063\u305f\u4e00\u3064\u306e\u30d7\u30ed\u30fc\u30d6\u3060\u3051\u30671\u907a\u4f1d\u5b50\u3092\u898b\u3066\u3044\u308b\u3068\u3044\u3046\u3053\u3068\u306f\u3001\u4eee\u306b\u305d\u306e\u30d7\u30ed\u30fc\u30d6\u304c\u4f55\u3089\u304b\u306e\u7406\u7531\u3067\u6a5f\u80fd\u3057\u306a\u304b\u3063\u305f\u5834\u5408\u306f\u3001\u305d\u306e\u907a\u4f1d\u5b50\u306e\u60c5\u5831\u304c\u5168\u304f\u5f97\u3089\u308c\u306a\u3044\u3053\u3068\u3092\u610f\u5473\u3057\u3066\u3044\u307e\u3059\u3002\u307e\u305f1\u3064\u306e\u30d7\u30ed\u30fc\u30d6\u30c7\u30fc\u30bf\u3067\u306f\u7d71\u8a08\u7684\u306a\u51e6\u7406\u304c\u3067\u304d\u307e\u305b\u3093\u306e\u3067\u3001\u30c7\u30fc\u30bf\u306e\u4fe1\u983c\u6027\u306b\u7591\u554f\u304c\u6b8b\u308a\u307e\u3059\u3002<\/p>\n<div id=\"attachment_1705\" style=\"width: 1034px\" class=\"wp-caption aligncenter\"><a href=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/about-clariom-d-fig2.png\" rel=\"attachment wp-att-1705\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-1705\" class=\"size-full wp-image-1705\" src=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/about-clariom-d-fig2.png\" alt=\"about-clariom-d-fig2\" width=\"1024\" height=\"345\" \/><\/a><p id=\"caption-attachment-1705\" class=\"wp-caption-text\">\u56f32 \u5f0a\u793e\u88fd\u30de\u30a4\u30af\u30ed\u30a2\u30ec\u30a4\u306e\u30d7\u30ed\u30fc\u30d6\u3068\u4ed6\u793e\u88fd\u30de\u30a4\u30af\u30ed\u30a2\u30ec\u30a4\u306e\u30d7\u30ed\u30fc\u30d6\u306e\u9055\u3044<\/p><\/div>\n<p>\u3053\u306e\u3088\u3046\u306a\u30c7\u30e1\u30ea\u30c3\u30c8\u306b\u3082\u304b\u304b\u308f\u3089\u305a\u5358\u4e00\u30d7\u30ed\u30fc\u30d6\u3067\u89e3\u6790\u305b\u3056\u308b\u3092\u5f97\u306a\u3044\u306e\u306f\u3001<strong>\u30de\u30a4\u30af\u30ed\u30a2\u30ec\u30a4\u306b\u642d\u8f09\u3067\u304d\u308b\u30d7\u30ed\u30fc\u30d6\u6570\u306b\u9650\u754c\u304c\u3042\u308b\u305f\u3081<\/strong>\u3067\u3059\u3002\u4e00\u822c\u7684\u306a\u30de\u30a4\u30af\u30ed\u30a2\u30ec\u30a4\u306b\u642d\u8f09\u3067\u304d\u308b\u30d7\u30ed\u30fc\u30d6\u6570\u306f\u6570\u4e07\u500b\u7a0b\u5ea6\u3057\u304b\u306a\u3044\u305f\u3081\u30011\u907a\u4f1d\u5b50\u306b\u8907\u6570\u306e\u30d7\u30ed\u30fc\u30d6\u3092\u5272\u308a\u5f53\u3066\u3066\u3057\u307e\u3046\u3068\u89e3\u6790\u3067\u304d\u308b\u907a\u4f1d\u5b50\u6570\u304c\u6e1b\u3063\u3066\u3057\u307e\u3046\u306e\u3067\u3059\u3002<\/p>\n<div id=\"attachment_1706\" style=\"width: 546px\" class=\"wp-caption aligncenter\"><a href=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/about-clariom-d-fig3.png\" rel=\"attachment wp-att-1706\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-1706\" class=\"size-full wp-image-1706\" src=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/about-clariom-d-fig3.png\" alt=\"about-clariom-d-fig3\" width=\"536\" height=\"374\" \/><\/a><p id=\"caption-attachment-1706\" class=\"wp-caption-text\">\u56f33 \u5f0a\u793e\u88fd\u30de\u30a4\u30af\u30ed\u30a2\u30ec\u30a4\u3068\u4e00\u822c\u7684\u306a\u767a\u73fe\u30a2\u30ec\u30a4\u3068\u306e\u30d7\u30ed\u30fc\u30d6\u6570\u306e\u9055\u3044<\/p><\/div>\n<p><strong>\u5f0a\u793e\u306e\u30de\u30a4\u30af\u30ed\u30a2\u30ec\u30a4\u306f\u534a\u5c0e\u88fd\u9020\u6280\u8853\u3092\u5fdc\u7528\u3057\u3066\u304a\u308a\u3001\u30d7\u30ed\u30fc\u30d6\u6570\u304c600\u4e07\u3092\u8d85\u3048\u308b\u3088\u3046\u306a\u8d85\u9ad8\u5bc6\u5ea6\u30de\u30a4\u30af\u30ed\u30a2\u30ec\u30a4\u3092\u4f5c\u6210\u3067\u304d\u307e\u3059\u3002<\/strong>\u3053\u308c\u306b\u3088\u308a\u3001<a href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/life-science\/microarray-analysis\/transcriptome-profiling-microarrays\/clariom-assays.html?CID=gsd_mic_gex_r04_jp_cp0000_pjt0000_gsd00000_0so_blg_op_awa_oc_s00_ma1_Social_LAB\" target=\"_blank\" rel=\"noopener noreferrer\">Clariom D<\/a>\u306e\u3088\u3046\u306b1\u907a\u4f1d\u5b50\u306b\u6570\u5341\u3082\u306e\u30d7\u30ed\u30fc\u30d6\u3092\u8a2d\u8a08\u3057\u3066\u3082\u306a\u304a\u6570\u4e07\u306b\u3082\u53ca\u3076\u907a\u4f1d\u5b50\u306e\u89e3\u6790\u304c\u53ef\u80fd\u306a\u306e\u3067\u3059\u3002<\/p>\n<h2>Clariom D\u3067\u89e3\u6790\u53ef\u80fd\u306a\u907a\u4f1d\u5b50<\/h2>\n<p><a href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/life-science\/microarray-analysis\/transcriptome-profiling-microarrays\/clariom-assays.html?CID=gsd_mic_gex_r04_jp_cp0000_pjt0000_gsd00000_0so_blg_op_awa_oc_s00_ma1_Social_LAB\" target=\"_blank\" rel=\"noopener noreferrer\">Clariom D<\/a>\u306e\u30d2\u30c8\u3001\u30de\u30a6\u30b9\u3001\u30e9\u30c3\u30c8\u305d\u308c\u305e\u308c\u306e\u88fd\u54c1\u3067\u89e3\u6790\u3067\u304d\u308b\u907a\u4f1d\u5b50\u6570\u306a\u3069\u306f\u4e0b\u8a18\u306e\u901a\u308a\u3068\u306a\u3063\u3066\u3044\u307e\u3059\u3002<\/p>\n<table>\n<caption>\u88681 Clariom D\u3067\u89e3\u6790\u3067\u304d\u308b\u907a\u4f1d\u5b50\u6570<\/caption>\n<tbody>\n<tr>\n<td style=\"text-align: center\"><strong>Content summary<\/strong><\/td>\n<td style=\"text-align: center\"><strong>Human<\/strong><\/td>\n<td style=\"text-align: center\"><strong>Mouse<\/strong><\/td>\n<td style=\"text-align: center\"><strong>Rat<\/strong><\/td>\n<\/tr>\n<tr>\n<td>Genes<sup>\u203b<\/sup><\/td>\n<td>&gt;134,700<\/td>\n<td>&gt;66,100<\/td>\n<td>&gt;68,900<\/td>\n<\/tr>\n<tr>\n<td>Transcripts<sup>\u203b<\/sup><\/td>\n<td>&gt;542,500<\/td>\n<td>&gt;214,900<\/td>\n<td>&gt;495,200<\/td>\n<\/tr>\n<tr>\n<td>Exons<sup>\u203b<\/sup><\/td>\n<td>&gt;948,300<\/td>\n<td>&gt;498,500<\/td>\n<td>&gt;320,400<\/td>\n<\/tr>\n<tr>\n<td>Exon-exon splice junctions<sup>\u203b<\/sup><\/td>\n<td>&gt;484,900<\/td>\n<td>&gt;282,500<\/td>\n<td>&gt;293,700<\/td>\n<\/tr>\n<tr>\n<td>Total probes<sup>\u203b<\/sup><\/td>\n<td>&gt;6,765,500<\/td>\n<td>&gt;6,022,300<\/td>\n<td>&gt;5,946,400<\/td>\n<\/tr>\n<tr>\n<td>Probes targeting exons<sup>\u203b<\/sup><\/td>\n<td>&gt;4,781,200<\/td>\n<td>&gt;4,895,600<\/td>\n<td>&gt;4,780,700<\/td>\n<\/tr>\n<tr>\n<td>Probes targeting exon-exon splice junctions<sup>\u203b<\/sup><\/td>\n<td>&gt;1,984,300<\/td>\n<td>&gt;1,126,700<\/td>\n<td>&gt;1,165,700<\/td>\n<\/tr>\n<tr>\n<td>Probe length(bases)<\/td>\n<td>25<\/td>\n<td>25<\/td>\n<td>25<\/td>\n<\/tr>\n<tr>\n<td>Probe feature size<\/td>\n<td>5\u03bcm<\/td>\n<td>5\u03bcm<\/td>\n<td>5\u03bcm<\/td>\n<\/tr>\n<tr>\n<td>Background probes<\/td>\n<td>Antigenomic Set<\/td>\n<td>Antigenomic Set<\/td>\n<td>Antigenomic Set<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><span style=\"font-size: 8pt\">\u203b2016\u5e744\u6708\u6642\u70b9\u3067\u306e\u4ee3\u8868\u7684\u306a\u30a2\u30ce\u30c6\u30fc\u30b7\u30e7\u30f3\u306e\u6570\u3067\u3059\u300210\u306e\u4f4d\u4ee5\u4e0b\u3092\u5207\u308a\u6368\u3066\u3066\u8868\u793a\u3057\u3066\u3044\u307e\u3059\u3002<\/span><br \/>\n\u4f8b\u3048\u3070\u30d2\u30c8\u7528\u306e<a href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/life-science\/microarray-analysis\/transcriptome-profiling-microarrays\/clariom-assays.html?CID=gsd_mic_gex_r04_jp_cp0000_pjt0000_gsd00000_0so_blg_op_awa_oc_s00_ma1_Social_LAB\" target=\"_blank\" rel=\"noopener noreferrer\">Clariom D<\/a>\u306f134,700\u4ee5\u4e0a\u306e\u907a\u4f1d\u5b50\u3092\u89e3\u6790\u3067\u304d\u3001\u3053\u306e\u4e2d\u306b\u306f542,500\u4ee5\u4e0a\u306e\u30b9\u30d7\u30e9\u30a4\u30b7\u30f3\u30b0\u30d0\u30ea\u30a2\u30f3\u30c8\u304c\u542b\u307e\u308c\u3066\u3044\u307e\u3059\u3002\u30d7\u30ed\u30fc\u30d6\u306e\u8a2d\u8a08\u306b\u3042\u305f\u3063\u3066\u306f15\u7a2e\u985e\u306b\u3082\u53ca\u3076\u30c7\u30fc\u30bf\u30d9\u30fc\u30b9\u3092\u5229\u7528\u3057\u3066\u304a\u308a\u3001\u73fe\u5728\u307e\u3067\u306b\u77e5\u3089\u308c\u3066\u3044\u308b\u30b9\u30d7\u30e9\u30a4\u30b7\u30f3\u30b0\u30d0\u30ea\u30a2\u30f3\u30c8\u3092\u7db2\u7f85\u3057\u3066\u3044\u307e\u3059\u3002<br \/>\n<a href=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/about-clariom-d-fig4.png\" rel=\"attachment wp-att-1707\"><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter size-full wp-image-1707\" src=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/about-clariom-d-fig4.png\" alt=\"about-clariom-d-fig4\" width=\"744\" height=\"693\" \/><\/a><br \/>\n\u307e\u305f\u30b3\u30fc\u30c7\u30a3\u30f3\u30b0\u907a\u4f1d\u5b50\u306e\u307f\u306a\u3089\u305a\u3001\u30ce\u30f3\u30b3\u30fc\u30c7\u30a3\u30f3\u30b0 (non-coding) \u907a\u4f1d\u5b50\u306b\u95a2\u3059\u308b\u30d7\u30ed\u30fc\u30d6\u3082\u8c4a\u5bcc\u306b\u542b\u307e\u308c\u3066\u3044\u308b\u305f\u3081\u3001\u30d0\u30a4\u30aa\u30de\u30fc\u30ab\u30fc\u63a2\u7d22\u306a\u3069\u306e\u305f\u3081\u306e\u60c5\u5831\u3092\u9003\u3057\u307e\u305b\u3093\u3002<\/p>\n<h2>RNA-Seq\u3092\u51cc\u3050\u7cbe\u5ea6\u3067\u4f4e\u767a\u73fe\u907a\u4f1d\u5b50\u3082\u3057\u3063\u304b\u308a\u89e3\u6790<\/h2>\n<p>\u8fd1\u5e74\u3001\u6b21\u4e16\u4ee3\u30b7\u30fc\u30b1\u30f3\u30b5\u30fc\uff08NGS\uff09\u306e\u6027\u80fd\u304c\u5411\u4e0a\u3059\u308b\u306b\u3064\u308c\u3066\u907a\u4f1d\u5b50\u306e\u767a\u73fe\u89e3\u6790\u3092NGS\u3067\u304a\u3053\u306a\u3046\u3001\u3044\u308f\u3086\u308bRNA-Seq\u306e\u30c6\u30af\u30ce\u30ed\u30b8\u30fc\u304c\u5e83\u304f\u7528\u3044\u3089\u308c\u308b\u3088\u3046\u306b\u306a\u3063\u3066\u304d\u307e\u3057\u305f\u3002<strong>\u767a\u73fe\u91cf\u3060\u3051\u3067\u306a\u304f\u914d\u5217\u60c5\u5831\u3082\u540c\u6642\u306b\u5f97\u3089\u308c\u308bRNA-Seq\u306f\u3001\u307e\u3055\u306b\u6b21\u4e16\u4ee3\u306e\u30c6\u30af\u30ce\u30ed\u30b8\u30fc\u3068\u3057\u3066\u69d8\u3005\u306a\u5834\u9762\u3067\u6d3b\u7528\u3055\u308c\u59cb\u3081\u3066\u3044\u307e\u3059\u3002<\/strong>\u4e00\u65b9\u3067RNA-Seq\u3092\u4f7f\u3044\u3053\u306a\u3059\u305f\u3081\u306b\u306f\u3001\u305d\u306e\u7279\u5fb4\u3092\u4e88\u3081\u3057\u3063\u304b\u308a\u3068\u628a\u63e1\u3057\u3066\u304a\u304f\u3053\u3068\u304c\u809d\u5fc3\u3067\u3059\u3002\u5834\u5408\u306b\u3088\u3063\u3066\u306f\u601d\u3063\u3066\u3044\u305f\u3088\u3046\u306a\u6027\u80fd\u304c\u51fa\u305a\u306b\u3001\u6642\u9593\u3068\u30b3\u30b9\u30c8\u3092\u7121\u99c4\u306b\u3057\u3066\u3057\u307e\u3044\u304b\u306d\u307e\u305b\u3093\u3002<\/p>\n<p>RNA-Seq\u306e\u6027\u80fd\u3092\u7aef\u7684\u306b\u8868\u3057\u305f\u3082\u306e\u3068\u3057\u3066\u3001\u4e0b\u56f3\u306e\u3088\u3046\u306a\u30c7\u30fc\u30bf\u304c\u3042\u308a\u307e\u3059\u3002<\/p>\n<div id=\"attachment_1709\" style=\"width: 970px\" class=\"wp-caption aligncenter\"><a href=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/about-clariom-d-fig5-1.jpg\" rel=\"attachment wp-att-1709\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-1709\" class=\"wp-image-1709 size-full\" src=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/about-clariom-d-fig5-1.jpg\" alt=\"about-clariom-d-fig5\" width=\"960\" height=\"560\" \/><\/a><p id=\"caption-attachment-1709\" class=\"wp-caption-text\">\u56f35 RNA-Seq\u3068\u30de\u30a4\u30af\u30ed\u30a2\u30ec\u30a4\u306b\u3088\u308b\u767a\u73fe\u89e3\u6790\u306e\u6bd4\u8f03\u3002<span style=\"font-size: 8pt\">\u203bXu, W., et al. Human transcriptome array for high throughput clinical studies. Proc Natl Acad Sci USA 108(9):3707\u20133712 (2011).<\/span><\/p><\/div>\n<p>\u4e0a\u56f3\u306fRNA-Seq\u3068\u30de\u30a4\u30af\u30ed\u30a2\u30ec\u30a4\u306b\u3088\u308b\u767a\u73fe\u89e3\u6790\u3092\u6bd4\u8f03\u3057\u305f\u3082\u306e\u3067\u3059\u3002\u56f3\u306e\u6a2a\u8ef8\u306f\u907a\u4f1d\u5b50\u306e\u767a\u73fe\u91cf\u3092\u3001\u7e26\u8ef8\u306f\u6e2c\u5b9a\u5024\u306e\u3070\u3089\u3064\u304d\u306e\u5927\u304d\u3055\u3092\u8868\u3057\u3066\u3044\u307e\u3059\u3002<\/p>\n<p>\u56f3\u306e\u5de6\u4e0a\u30011500\u4e07\u3068\u8d64\u5b57\u3067\u66f8\u304b\u308c\u3066\u3044\u308b\u30b0\u30e9\u30d5\u306b\u6ce8\u76ee\u3057\u3066\u304f\u3060\u3055\u3044\u3002\u3053\u306e\u8d64\u5b57\u306fRNA-Seq\u306e\u30ea\u30fc\u30c9\u6570\u3092\u793a\u3057\u3066\u3044\u307e\u3059\u3002\u30de\u30a4\u30af\u30ed\u30a2\u30ec\u30a4\u306f\u4f4e\u767a\u73fe\u306e\u907a\u4f1d\u5b50\u3067\u3082\u6e2c\u5b9a\u5024\u306e\u3070\u3089\u3064\u304d\u304c\u5c0f\u3055\u3044\u306e\u306b\u5bfe\u3057\u3001RNA-Seq\u3067\u306f\u767a\u73fe\u91cf\u304c\u4f4e\u304f\u306a\u308b\u306b\u3064\u308c\u3066\u6e2c\u5b9a\u306e\u3070\u3089\u3064\u304d\u304c\u3069\u3093\u3069\u3093\u5927\u304d\u304f\u306a\u3063\u3066\u3044\u308b\u3053\u3068\u304c\u5206\u304b\u308a\u307e\u3059\u3002\u3053\u306e\u3088\u3046\u306b\u3001<strong>\u30ea\u30fc\u30c9\u6570\u304c\u5c11\u306a\u3044\u6761\u4ef6\u3067\u306eRNA-Seq\u3067\u306f\u4f4e\u767a\u73fe\u306e\u907a\u4f1d\u5b50\u3092\u7cbe\u5ea6\u3088\u304f\u89e3\u6790\u3067\u304d\u307e\u305b\u3093\u3002\u3082\u3057\u3082RNA-Seq\u3067\u4f4e\u767a\u73fe\u907a\u4f1d\u5b50\u3092\u9ad8\u7cbe\u5ea6\u3067\u89e3\u6790\u3057\u305f\u3051\u308c\u3070\u3001\u30ea\u30fc\u30c9\u6570\u3092\u5897\u3084\u3057\u3066\u3044\u304f\u5fc5\u8981\u304c\u3042\u308a\u307e\u3059\u3002<\/strong>\u56f3\u306e\u53f3\u4e0b\u306e\u3088\u3046\u306b4.8\u5104\u30ea\u30fc\u30c9\u307e\u3067\u30ea\u30fc\u30c9\u6570\u3092\u5897\u3084\u3059\u3053\u3068\u306b\u3088\u308a\u3001\u3088\u3046\u3084\u304f\u30de\u30a4\u30af\u30ed\u30a2\u30ec\u30a4\u3068\u540c\u7a0b\u5ea6\u306e\u89e3\u6790\u6027\u80fd\u3092\u6301\u3064\u3053\u3068\u304c\u5206\u304b\u308a\u307e\u3059\u3002<\/p>\n<p>\u4e00\u822c\u7684\u306b\u304a\u3053\u306a\u308f\u308c\u3066\u3044\u308bRNA-Seq\u3067\u306f\u30ea\u30fc\u30c9\u6570\u306b\u3057\u30664000\u4e07 (40 million) \u7a0b\u5ea6\u3067\u89e3\u6790\u3059\u308b\u3053\u3068\u304c\u591a\u3044\u3088\u3046\u3067\u3059\u3002\u4e0a\u8ff0\u3057\u305f\u3068\u304a\u308a\u3001\u4f4e\u767a\u73fe\u306e\u907a\u4f1d\u5b50\u307e\u3067\u7cbe\u5ea6\u3088\u304f\u6e2c\u5b9a\u3059\u308b\u305f\u3081\u306b\u306f\u5c11\u306a\u304f\u3068\u3082\u3053\u306e10\u500d\u4ee5\u4e0a\u306e\u30ea\u30fc\u30c9\u6570\u304c\u5fc5\u8981\u3067\u3059\u3002\u305d\u308c\u306f\u3059\u306a\u308f\u3061\u3001\u4e00\u822c\u7684\u306aRNA-Seq\u306b\u6bd4\u3079\u306610\u500d\u306e\u30b3\u30b9\u30c8\u304c\u304b\u304b\u308b\u3053\u3068\u3092\u610f\u5473\u3057\u3066\u3044\u307e\u3059\u3002<strong>RNA-Seq\u3067\u3057\u304b\u5f97\u3089\u308c\u306a\u3044\u60c5\u5831\u304c\u5fc5\u8981\u3067\u3042\u308c\u3070\u3053\u306e\u30b3\u30b9\u30c8\u306f\u5fc5\u8981\u7d4c\u8cbb\u3068\u3057\u3066\u5272\u308a\u5207\u308c\u307e\u3059\u304c\u3001\u3082\u3057\u3082\u30c7\u30fc\u30bf\u30d9\u30fc\u30b9\u4e0a\u306b\u3042\u308b\u65e2\u5b58\u907a\u4f1d\u5b50\u306e\u89e3\u6790\u304c\u4e3b\u306a\u76ee\u7684\u3067\u3042\u308b\u306e\u306a\u3089\u3070\u3001<a href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/life-science\/microarray-analysis\/transcriptome-profiling-microarrays\/clariom-assays.html?CID=gsd_mic_gex_r04_jp_cp0000_pjt0000_gsd00000_0so_blg_op_awa_oc_s00_ma1_Social_LAB\" target=\"_blank\" rel=\"noopener noreferrer\">Clariom D<\/a>\u3092\u7528\u3044\u305f\u65b9\u304c\u306f\u308b\u304b\u306b\u9ad8\u7cbe\u5ea6\u304b\u3064\u4f4e\u30b3\u30b9\u30c8\u3067\u89e3\u6790\u3067\u304d\u308b\u306e\u3067\u3059\u3002<\/strong><\/p>\n<h2>\u907a\u4f1d\u5b50\u30ec\u30d9\u30eb\u3092\u8d85\u3048\u305f\u3001\u30c8\u30e9\u30f3\u30b9\u30af\u30ea\u30d7\u30c8\u30fc\u30e0\u30ec\u30d9\u30eb\u89e3\u6790\u3092\u5b9f\u73fe<\/h2>\n<p><a href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/life-science\/microarray-analysis\/transcriptome-profiling-microarrays\/clariom-assays.html?CID=gsd_mic_gex_r04_jp_cp0000_pjt0000_gsd00000_0so_blg_op_awa_oc_s00_ma1_Social_LAB\" target=\"_blank\" rel=\"noopener noreferrer\">Clariom D<\/a>\u306f\u5f93\u6765\u306e\u30de\u30a4\u30af\u30ed\u30a2\u30ec\u30a4\u3067\u4e00\u822c\u7684\u306b\u304a\u3053\u306a\u308f\u308c\u3066\u3044\u308b\u907a\u4f1d\u5b50\u30ec\u30d9\u30eb\u306e\u767a\u73fe\u89e3\u6790\u306e\u307b\u304b\u306b\u3001\u9078\u629e\u7684\u30b9\u30d7\u30e9\u30a4\u30b7\u30f3\u30b0\u306b\u3088\u308b\u30b9\u30d7\u30e9\u30a4\u30b7\u30f3\u30b0\u30d0\u30ea\u30a2\u30f3\u30c8\u89e3\u6790\u3084\u3001long non-coding RNA (lncRNA) \u89e3\u6790\u306a\u3069\u3001<strong>\u30c8\u30e9\u30f3\u30b9\u30af\u30ea\u30d7\u30c8\u30fc\u30e0\u30ec\u30d9\u30eb\u3067\u306e\u89e3\u6790\u3092\u304a\u3053\u306a\u3046\u3053\u3068\u304c\u3067\u304d\u308b\u6b21\u4e16\u4ee3\u578b\u30de\u30a4\u30af\u30ed\u30a2\u30ec\u30a4\u3067\u3059\u3002<\/strong>\u3053\u3053\u3067\u306f\u3001<a href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/life-science\/microarray-analysis\/transcriptome-profiling-microarrays\/clariom-assays.html?CID=Social_LAB\" target=\"_blank\" rel=\"noopener noreferrer\">Clariom D<\/a>\u306b\u3088\u308b\u30c8\u30e9\u30f3\u30b9\u30af\u30ea\u30d7\u30c8\u30fc\u30e0\u30ec\u30d9\u30eb\u89e3\u6790\u306b\u3064\u3044\u3066\u3054\u7d39\u4ecb\u3057\u305f\u3044\u3068\u601d\u3044\u307e\u3059\u3002<\/p>\n<h3>\u9078\u629e\u7684\u30b9\u30d7\u30e9\u30a4\u30b7\u30f3\u30b0\u306b\u3088\u308b\u30b9\u30d7\u30e9\u30a4\u30b7\u30f3\u30b0\u30d0\u30ea\u30a2\u30f3\u30c8\u89e3\u6790<\/h3>\n<p><a href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/life-science\/microarray-analysis\/transcriptome-profiling-microarrays\/clariom-assays.html?CID=Social_LAB\" target=\"_blank\" rel=\"noopener noreferrer\">Clariom D<\/a>\u306e\u8d85\u9ad8\u5bc6\u5ea6\u30d7\u30ed\u30fc\u30d6\u306f\u907a\u4f1d\u5b50\u9818\u57df\u3092\u304f\u307e\u306a\u304f\u30ab\u30d0\u30fc\u3059\u308b\u3060\u3051\u3067\u306a\u304f\u3001\u30a8\u30af\u30bd\u30f3\u30b8\u30e3\u30f3\u30af\u30b7\u30e7\u30f3\u90e8\u306b\u3082\u8a2d\u8a08\u3055\u308c\u3066\u3044\u307e\u3059\u3002\u3053\u308c\u306b\u3088\u308a<strong>\u30a8\u30af\u30bd\u30f3\u30ec\u30d9\u30eb\u3067\u306e\u7cbe\u5bc6\u306a\u767a\u73fe\u89e3\u6790\u304c\u53ef\u80fd\u3068\u306a\u308a\u3001\u9078\u629e\u7684\u30b9\u30d7\u30e9\u30a4\u30b7\u30f3\u30b0\u306b\u3088\u308b\u30b9\u30d7\u30e9\u30a4\u30b7\u30f3\u30b0\u30d0\u30ea\u30a2\u30f3\u30c8\u89e3\u6790\u3092\u304a\u3053\u306a\u3046\u3053\u3068\u304c\u3067\u304d\u307e\u3059\u3002<\/strong><\/p>\n<p>\u4f8b\u3048\u3070\u5192\u982d\u306eCOLCA2\u907a\u4f1d\u5b50\u306f\u3001\u6700\u65b0\u306e\u30c7\u30fc\u30bf\u30d9\u30fc\u30b9\u306e\u77e5\u898b\u306b\u3088\u308a10\u7a2e\u985e\u306e\u30b9\u30d7\u30e9\u30a4\u30b7\u30f3\u30b0\u30d0\u30ea\u30a2\u30f3\u30c8\u304c\u5b58\u5728\u3057\u3066\u3044\u308b\u3053\u3068\u304c\u77e5\u3089\u308c\u3066\u3044\u307e\u3059\u3002<br \/>\n<a href=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/about-clariom-d-fig6-1.png\" rel=\"attachment wp-att-1710\"><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter size-full wp-image-1710\" src=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/about-clariom-d-fig6-1.png\" alt=\"about-clariom-d-fig6\" width=\"714\" height=\"312\" \/><\/a><br \/>\n<a href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/life-science\/microarray-analysis\/transcriptome-profiling-microarrays\/clariom-assays.html?CID=gsd_mic_gex_r04_jp_cp0000_pjt0000_gsd00000_0so_blg_op_awa_oc_s00_ma1_Social_LAB\" target=\"_blank\" rel=\"noopener noreferrer\">Clariom D<\/a>\u306f\u907a\u4f1d\u5b50\u306e\u767a\u73fe\u30ec\u30d9\u30eb\u306b\u52a0\u3048\u3001\u5404\u30a8\u30af\u30bd\u30f3\u3054\u3068\u306e\u767a\u73fe\u30ec\u30d9\u30eb\u3082\u540c\u6642\u306b\u89e3\u6790\u3057\u307e\u3059\u3002\u5c02\u7528\u306e\u89e3\u6790\u30bd\u30d5\u30c8\u3092\u7528\u3044\u308c\u3070\u3001\u30b5\u30f3\u30d7\u30eb\u4e2d\u306b\u542b\u307e\u308c\u308b\u30d0\u30ea\u30a2\u30f3\u30c8\u306e\u3046\u3061\u3001\u3069\u306e\u30bf\u30a4\u30d7\u304c\u3082\u3063\u3068\u3082\u591a\u304f\u767a\u73fe\u3057\u3066\u3044\u308b\u304b\u3092\u4e88\u6e2c\u3067\u304d\u307e\u3059\u3002<\/p>\n<h3>long non-coding RNA (lncRNA) \u89e3\u6790<\/h3>\n<p><a href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/life-science\/microarray-analysis\/transcriptome-profiling-microarrays\/clariom-assays.html?CID=Social_LAB\" target=\"_blank\" rel=\"noopener noreferrer\">Clariom D<\/a>\u306b\u306flong non-coding RNA (lncRNA) \u3092\u89e3\u6790\u3059\u308b\u305f\u3081\u306e\u30d7\u30ed\u30fc\u30d6\u304c\u6570\u591a\u304f\u642d\u8f09\u3055\u308c\u3066\u3044\u307e\u3059\u3002\u4e0b\u8a18\u306e\u8868\u306f<a href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/life-science\/microarray-analysis\/transcriptome-profiling-microarrays\/clariom-assays.html?CID=gsd_mic_gex_r04_jp_cp0000_pjt0000_gsd00000_0so_blg_op_awa_oc_s00_ma1_Social_LAB\" target=\"_blank\" rel=\"noopener noreferrer\">Clariom D<\/a>\u3092\u8a2d\u8a08\u3059\u308b\u969b\u306b\u7528\u3044\u3089\u308c\u305f\u30c7\u30fc\u30bf\u30d9\u30fc\u30b9\u306e\u4e00\u89a7\u3068\u3001\u63a1\u7528\u3055\u308c\u305f\u907a\u4f1d\u5b50\u6570\u3092\u8868\u3057\u305f\u3082\u306e\u3067\u3059\u3002<\/p>\n<table>\n<caption>\u88682 Clariom D\u3092\u8a2d\u8a08\u3059\u308b\u969b\u306b\u7528\u3044\u3089\u308c\u305f\u30c7\u30fc\u30bf\u30d9\u30fc\u30b9\u304a\u3088\u3073Clariom D\u306b\u63a1\u7528\u3055\u308c\u305f\u907a\u4f1d\u5b50\u6570<\/caption>\n<tbody>\n<tr>\n<td style=\"text-align: center\" rowspan=\"2\"><strong>Data sources<\/strong><strong>\u00a0<\/strong><\/td>\n<td style=\"text-align: center\" colspan=\"3\"><strong>Genes<\/strong><\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center\"><strong>Human<\/strong><\/td>\n<td style=\"text-align: center\"><strong>Mouse<\/strong><\/td>\n<td style=\"text-align: center\"><strong>Rat<\/strong><\/td>\n<\/tr>\n<tr>\n<td>Ensembl<\/td>\n<td>&gt;57,500<\/td>\n<td>&gt;57,500<\/td>\n<td>&gt;25,300<\/td>\n<\/tr>\n<tr>\n<td>VEGA<\/td>\n<td>&gt;48,500<\/td>\n<td>&gt;23,200<\/td>\n<td>\u2013<\/td>\n<\/tr>\n<tr>\n<td>NONCODE<\/td>\n<td>&gt;55,900<\/td>\n<td>&gt;42,000<\/td>\n<td>&gt;500<\/td>\n<\/tr>\n<tr>\n<td>lncRNAWiki<\/td>\n<td>&gt;50,000<\/td>\n<td>\u2013<\/td>\n<td>\u2013<\/td>\n<\/tr>\n<tr>\n<td>UCSC Genes<\/td>\n<td>&gt;43,800<\/td>\n<td>&gt;26,300<\/td>\n<td>\u2013<\/td>\n<\/tr>\n<tr>\n<td>AceView<\/td>\n<td>&gt;41,100<\/td>\n<td>\u2013<\/td>\n<td>&gt;30,900<\/td>\n<\/tr>\n<tr>\n<td>miTranscriptome<\/td>\n<td>&gt;34,500<\/td>\n<td>\u2013<\/td>\n<td>\u2013<\/td>\n<\/tr>\n<tr>\n<td>RefSeq<\/td>\n<td>&gt;25,600<\/td>\n<td>&gt;23,500<\/td>\n<td>&gt;16,900<\/td>\n<\/tr>\n<tr>\n<td>MGC<\/td>\n<td>&gt;17,200<\/td>\n<td>&gt;17,400<\/td>\n<td>&gt;6,400<\/td>\n<\/tr>\n<tr>\n<td>MGI<\/td>\n<td>\u2013<\/td>\n<td>&gt;25,800<\/td>\n<td>\u2013<\/td>\n<\/tr>\n<tr>\n<td>RGD<\/td>\n<td>\u2013<\/td>\n<td>\u2013<\/td>\n<td>&gt;30,300<\/td>\n<\/tr>\n<tr>\n<td>Consensus CDS<\/td>\n<td>&gt;18,500<\/td>\n<td>\u2013<\/td>\n<td>\u2013<\/td>\n<\/tr>\n<tr>\n<td>RNA Central<\/td>\n<td>&gt;17,200<\/td>\n<td>\u2013<\/td>\n<td>\u2013<\/td>\n<\/tr>\n<tr>\n<td>circBase<\/td>\n<td>&gt;12,200<\/td>\n<td>\u2013<\/td>\n<td>\u2013<\/td>\n<\/tr>\n<tr>\n<td>Human Body Map<\/td>\n<td>&gt;10,200<\/td>\n<td>\u2013<\/td>\n<td>\u2013<\/td>\n<\/tr>\n<tr>\n<td>lincRNAdb<\/td>\n<td>&gt;80<\/td>\n<td>&gt;60<\/td>\n<td>&gt;10<\/td>\n<\/tr>\n<tr>\n<td>Publication-specific gene sets<\/td>\n<td>&gt;3,000<\/td>\n<td>&gt;10,000<\/td>\n<td>&gt;10,290<\/td>\n<\/tr>\n<tr>\n<td>Non-overlapping orthologous mouse gene and transcript models<\/td>\n<td>\u2013<\/td>\n<td>\u2013<\/td>\n<td>&gt;21,500<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>\u3053\u306e\u8868\u304b\u3089\u660e\u3089\u304b\u306a\u3088\u3046\u306b<a href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/life-science\/microarray-analysis\/transcriptome-profiling-microarrays\/clariom-assays.html?CID=gsd_mic_gex_r04_jp_cp0000_pjt0000_gsd00000_0so_blg_op_awa_oc_s00_ma1_Social_LAB\" target=\"_blank\" rel=\"noopener noreferrer\">Clariom D<\/a>\u306b\u306fnon-coding RNA\u306e\u30c7\u30fc\u30bf\u30d9\u30fc\u30b9\u3092\u5143\u306b\u3057\u3066\u6570\u591a\u304f\u306e\u30d7\u30ed\u30fc\u30d6\u304c\u8a2d\u8a08\u3055\u308c\u3066\u3044\u307e\u3059\u3002\u3053\u308c\u306b\u3088\u308a\u3001<strong>\u4eca\u307e\u3067\u898b\u904e\u3054\u3055\u308c\u3066\u304d\u305flncRNA\u306e\u767a\u73fe\u5909\u52d5\u3092\u78ba\u5b9f\u306b\u3068\u3089\u3048\u308b\u3053\u3068\u304c\u3067\u304d\u307e\u3059\u3002<\/strong><\/p>\n<p>\u4e00\u822c\u7684\u306blncRNA\u306e\u767a\u73fe\u30ec\u30d9\u30eb\u306f\u304b\u306a\u308a\u4f4e\u3044\u305f\u3081\u3001\u5148\u8ff0\u3057\u305fRNA-Seq\u3067\u89e3\u6790\u3092\u3059\u308b\u305f\u3081\u306b\u306f\u76f8\u5f53\u6570\u306e\u30ea\u30fc\u30c9\u6570\u3092\u8aad\u3080\u5fc5\u8981\u304c\u3042\u308a\u3001\u3044\u308f\u3086\u308bDeep Sequencing\u304c\u5fc5\u8981\u3068\u8003\u3048\u3089\u308c\u3066\u3044\u307e\u3059<sup>\u203b<\/sup>\u3002\u4e00\u65b9\u3067Deep Sequencing\u306f\u89e3\u6790\u30b3\u30b9\u30c8\u304c\u5897\u5927\u3059\u308b\u3070\u304b\u308a\u3067\u306a\u304f\u3001\u30c7\u30fc\u30bf\u89e3\u6790\u306e\u305f\u3081\u306e\u624b\u9593\u3084\u6642\u9593\u3082\u304b\u304b\u3063\u3066\u3057\u307e\u3044\u307e\u3059\u3002<strong><a href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/life-science\/microarray-analysis\/transcriptome-profiling-microarrays\/clariom-assays.html?CID=gsd_mic_gex_r04_jp_cp0000_pjt0000_gsd00000_0so_blg_op_awa_oc_s00_ma1_Social_LAB\" target=\"_blank\" rel=\"noopener noreferrer\">Clariom D<\/a>\u306f\u5c02\u7528\u306e\u89e3\u6790\u30bd\u30d5\u30c8\u306b\u3088\u308a\u3069\u306a\u305f\u3067\u3082\u7c21\u5358\u306blncRNA\u306e\u767a\u73fe\u3092\u89e3\u6790\u3067\u304d\u308b\u305f\u3081\u3001lncRNA\u3092\u30bf\u30fc\u30b2\u30c3\u30c8\u3068\u3057\u305f\u7814\u7a76\u306b\u5927\u304d\u306a\u5a01\u529b\u3092\u767a\u63ee\u3057\u307e\u3059\u3002<\/strong><br \/>\n<span style=\"font-size: 8pt\">\u203bLiu, Y., et al. Evaluating the impact of sequencing depth on transcriptome profiling in human adipose. PLoS One 8(6):e66883 (2013).<\/span><\/p>\n<h2>\u307e\u3068\u3081<\/h2>\n<p>\u4eca\u56de\u306f\u6b21\u4e16\u4ee3\u578b\u8d85\u9ad8\u5bc6\u5ea6\u30de\u30a4\u30af\u30ed\u30a2\u30ec\u30a4<a href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/life-science\/microarray-analysis\/transcriptome-profiling-microarrays\/clariom-assays.html?CID=gsd_mic_gex_r04_jp_cp0000_pjt0000_gsd00000_0so_blg_op_awa_oc_s00_ma1_Social_LAB\" target=\"_blank\" rel=\"noopener noreferrer\">Clariom D<\/a>\u306e\u7279\u5fb4\u3068\u6027\u80fd\u306b\u3064\u3044\u3066\u307f\u3066\u304d\u307e\u3057\u305f\u3002<\/p>\n<p>\u73fe\u5728\u3001\u6b21\u4e16\u4ee3\u30b7\u30fc\u30b1\u30f3\u30b5\u30fc\u3092\u7528\u3044\u305f\u767a\u73fe\u89e3\u6790\u306f\u6d41\u884c\u3068\u3044\u3063\u3066\u3044\u3044\u30ec\u30d9\u30eb\u3067\u5e83\u7bc4\u56f2\u306b\u308f\u305f\u3063\u3066\u5b9f\u65bd\u3055\u308c\u3066\u3044\u307e\u3059\u304c\u3001RNA-Seq\u3067\u3067\u304d\u308b\u3053\u3068\u3001\u3067\u304d\u306a\u3044\u3053\u3068\u3092\u898b\u6975\u3081\u305f\u4e0a\u3067\u5b9f\u9a13\u3092\u3057\u3066\u3044\u308b\u4eba\u306f\u610f\u5916\u3068\u591a\u304f\u3042\u308a\u307e\u305b\u3093\u3002\u9650\u3089\u308c\u305f\u7814\u7a76\u4e88\u7b97\u306e\u4e2d\u3067\u771f\u306e\u610f\u5473\u3067\u306e\u4fa1\u5024\u3042\u308b\u30c7\u30fc\u30bf\u3092\u51fa\u3059\u305f\u3081\u306b\u306f\u3001\u6642\u6d41\u306b\u3068\u3089\u308f\u308c\u306a\u3044\u5408\u7406\u7684\u306a\u5224\u65ad\u304c\u6c42\u3081\u3089\u308c\u3066\u3044\u307e\u3059\u3002<a href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/life-science\/microarray-analysis\/transcriptome-profiling-microarrays\/clariom-assays.html?CID=gsd_mic_gex_r04_jp_cp0000_pjt0000_gsd00000_0so_blg_op_awa_oc_s00_ma1_Social_LAB\" target=\"_blank\" rel=\"noopener noreferrer\">Clariom D<\/a>\u306f\u3001\u672a\u6765\u306b\u7e4b\u304c\u308b\u30c7\u30fc\u30bf\u3092\u6c42\u3081\u308b\u7814\u7a76\u8005\u306b\u3068\u3063\u3066\u6700\u5584\u306e\u7d50\u679c\u3092\u3082\u305f\u3089\u3059\u3053\u3068\u3067\u3057\u3087\u3046\u3002<\/p>\n<p>\u7814\u7a76\u7528\u306b\u306e\u307f\u4f7f\u7528\u3067\u304d\u307e\u3059\u3002\u8a3a\u65ad\u76ee\u7684\u304a\u3088\u3073\u305d\u306e\u624b\u7d9a\u304d\u4e0a\u3067\u306e\u4f7f\u7528\u306f\u3067\u304d\u307e\u305b\u3093\u3002<\/p>\n","protected":false},"excerpt":{"rendered":"<p>\u5f0a\u793e\u306e\u6b21\u4e16\u4ee3\u578b\u767a\u73fe\u89e3\u6790\u30de\u30a4\u30af\u30ed\u30a2\u30ec\u30a4\u300cClariom D\u300d\u306f\u3001\u5f93\u6765\u306e\u767a\u73fe\u89e3\u6790\u306b\u52a0\u3048\u3001\u9078\u629e\u7684\u30b9\u30d7\u30e9\u30a4\u30b7\u30f3\u30b0\u89e3\u6790\u3084long non-coding RNA (lncRNA) \u89e3\u6790\u306a\u3069\u3001\u30c8\u30e9\u30f3\u30b9\u30af\u30ea\u30d7\u30c8\u30fc\u30e0\u30ec\u30d9\u30eb\u3067\u306e\u89e3\u6790\u306b\u3082\u5a01\u529b\u3092\u767a\u63ee\u3057\u307e\u3059\u3002\u4eca\u56de\u306f\u3001Clariom D\u306e\u5727\u5012\u7684\u306a\u89e3\u6790\u6027\u80fd\u306b\u3064\u3044\u3066\u307e\u3068\u3081\u3066\u307f\u307e\u3057\u305f\u3002<\/p>\n","protected":false},"author":988,"featured_media":3007,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_monsterinsights_skip_tracking":false,"_genesis_hide_title":false,"_genesis_hide_breadcrumbs":false,"_genesis_hide_singular_image":false,"_genesis_hide_footer_widgets":false,"_genesis_custom_body_class":"","_genesis_custom_post_class":"","_genesis_layout":"","_jetpack_newsletter_access":"","_jetpack_dont_email_post_to_subs":false,"_jetpack_newsletter_tier_id":0,"_jetpack_memberships_contains_paywalled_content":false,"_jetpack_hide_featured_image":false,"_jetpack_featured_image_duplicate_dismissed":0,"_jetpack_feature_clip_id":0,"_jetpack_memberships_contains_paid_content":false,"footnotes":"","jetpack_post_was_ever_published":false},"categories":[156],"tags":[71],"division":[],"class_list":["post-594","post","type-post","status-publish","format-standard","has-post-thumbnail","category-mol-bio","tag-microarray","entry"],"_selected_authors":"","_selected_reviewers":"","acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v28.9 (Yoast SEO v28.9) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>\u6b21\u4e16\u4ee3\u578b\u8d85\u9ad8\u5bc6\u5ea6\u30de\u30a4\u30af\u30ed\u30a2\u30ec\u30a4 Clariom D \u306e\u5727\u5012\u7684\u306a\u89e3\u6790\u6027\u80fd\u3068\u306f\uff1f - Learning at the Bench<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/about-clariom-d\/\" \/>\n<meta property=\"og:locale\" content=\"ja_JP\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"\u6b21\u4e16\u4ee3\u578b\u8d85\u9ad8\u5bc6\u5ea6\u30de\u30a4\u30af\u30ed\u30a2\u30ec\u30a4 Clariom D \u306e\u5727\u5012\u7684\u306a\u89e3\u6790\u6027\u80fd\u3068\u306f\uff1f\" \/>\n<meta property=\"og:description\" content=\"\u5f0a\u793e\u306e\u6b21\u4e16\u4ee3\u578b\u767a\u73fe\u89e3\u6790\u30de\u30a4\u30af\u30ed\u30a2\u30ec\u30a4\u300cClariom D\u300d\u306f\u3001\u5f93\u6765\u306e\u767a\u73fe\u89e3\u6790\u306b\u52a0\u3048\u3001\u9078\u629e\u7684\u30b9\u30d7\u30e9\u30a4\u30b7\u30f3\u30b0\u89e3\u6790\u3084long non-coding RNA (lncRNA) \u89e3\u6790\u306a\u3069\u3001\u30c8\u30e9\u30f3\u30b9\u30af\u30ea\u30d7\u30c8\u30fc\u30e0\u30ec\u30d9\u30eb\u3067\u306e\u89e3\u6790\u306b\u3082\u5a01\u529b\u3092\u767a\u63ee\u3057\u307e\u3059\u3002\u4eca\u56de\u306f\u3001Clariom D\u306e\u5727\u5012\u7684\u306a\u89e3\u6790\u6027\u80fd\u306b\u3064\u3044\u3066\u307e\u3068\u3081\u3066\u307f\u307e\u3057\u305f\u3002\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/about-clariom-d\/\" \/>\n<meta property=\"og:site_name\" content=\"Learning at the Bench\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/ThermoFisherJapan\" \/>\n<meta property=\"article:published_time\" content=\"2017-02-07T00:00:00+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2021-12-14T05:31:45+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/about-clariom-d-title.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"1199\" \/>\n\t<meta property=\"og:image:height\" content=\"630\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"LATB Staff\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:creator\" content=\"@ThermoFisherJP\" \/>\n<meta name=\"twitter:site\" content=\"@ThermoFisherJP\" \/>\n<meta name=\"twitter:label1\" content=\"\u57f7\u7b46\u8005\" \/>\n\t<meta name=\"twitter:data1\" content=\"LATB Staff\" \/>\n\t<meta name=\"twitter:label2\" content=\"\u63a8\u5b9a\u8aad\u307f\u53d6\u308a\u6642\u9593\" \/>\n\t<meta name=\"twitter:data2\" content=\"1\u5206\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/about-clariom-d\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/about-clariom-d\\\/\"},\"author\":{\"name\":\"LATB Staff\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#\\\/schema\\\/person\\\/201e6a5abb838fa34e8ff0174b015d36\"},\"headline\":\"\u6b21\u4e16\u4ee3\u578b\u8d85\u9ad8\u5bc6\u5ea6\u30de\u30a4\u30af\u30ed\u30a2\u30ec\u30a4 Clariom D \u306e\u5727\u5012\u7684\u306a\u89e3\u6790\u6027\u80fd\u3068\u306f\uff1f\",\"datePublished\":\"2017-02-07T00:00:00+00:00\",\"dateModified\":\"2021-12-14T05:31:45+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/about-clariom-d\\\/\"},\"wordCount\":300,\"commentCount\":0,\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/about-clariom-d\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2019\\\/07\\\/about-clariom-d-title.jpg\",\"keywords\":[\"\u30de\u30a4\u30af\u30ed\u30a2\u30ec\u30a4\"],\"articleSection\":[\"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023\"],\"inLanguage\":\"ja\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/about-clariom-d\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/about-clariom-d\\\/\",\"url\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/about-clariom-d\\\/\",\"name\":\"\u6b21\u4e16\u4ee3\u578b\u8d85\u9ad8\u5bc6\u5ea6\u30de\u30a4\u30af\u30ed\u30a2\u30ec\u30a4 Clariom D \u306e\u5727\u5012\u7684\u306a\u89e3\u6790\u6027\u80fd\u3068\u306f\uff1f - Learning at the Bench\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/about-clariom-d\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/about-clariom-d\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2019\\\/07\\\/about-clariom-d-title.jpg\",\"datePublished\":\"2017-02-07T00:00:00+00:00\",\"dateModified\":\"2021-12-14T05:31:45+00:00\",\"author\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#\\\/schema\\\/person\\\/201e6a5abb838fa34e8ff0174b015d36\"},\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/about-clariom-d\\\/#breadcrumb\"},\"inLanguage\":\"ja\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/about-clariom-d\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"ja\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/about-clariom-d\\\/#primaryimage\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2019\\\/07\\\/about-clariom-d-title.jpg\",\"contentUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2019\\\/07\\\/about-clariom-d-title.jpg\",\"width\":1199,\"height\":630,\"caption\":\"about-clariom-d-title\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/about-clariom-d\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"\u6b21\u4e16\u4ee3\u578b\u8d85\u9ad8\u5bc6\u5ea6\u30de\u30a4\u30af\u30ed\u30a2\u30ec\u30a4 Clariom D \u306e\u5727\u5012\u7684\u306a\u89e3\u6790\u6027\u80fd\u3068\u306f\uff1f\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#website\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/\",\"name\":\"Learning at the Bench\",\"description\":\"\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"ja\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#\\\/schema\\\/person\\\/201e6a5abb838fa34e8ff0174b015d36\",\"name\":\"LATB Staff\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"ja\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/8803277856c8b753feb4217dff0f9953327452df1a615c3c88b2f9864efb2ddd?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/8803277856c8b753feb4217dff0f9953327452df1a615c3c88b2f9864efb2ddd?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/8803277856c8b753feb4217dff0f9953327452df1a615c3c88b2f9864efb2ddd?s=96&d=mm&r=g\",\"caption\":\"LATB Staff\"},\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/author\\\/latbstaff\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"\u6b21\u4e16\u4ee3\u578b\u8d85\u9ad8\u5bc6\u5ea6\u30de\u30a4\u30af\u30ed\u30a2\u30ec\u30a4 Clariom D \u306e\u5727\u5012\u7684\u306a\u89e3\u6790\u6027\u80fd\u3068\u306f\uff1f - Learning at the Bench","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/about-clariom-d\/","og_locale":"ja_JP","og_type":"article","og_title":"\u6b21\u4e16\u4ee3\u578b\u8d85\u9ad8\u5bc6\u5ea6\u30de\u30a4\u30af\u30ed\u30a2\u30ec\u30a4 Clariom D \u306e\u5727\u5012\u7684\u306a\u89e3\u6790\u6027\u80fd\u3068\u306f\uff1f","og_description":"\u5f0a\u793e\u306e\u6b21\u4e16\u4ee3\u578b\u767a\u73fe\u89e3\u6790\u30de\u30a4\u30af\u30ed\u30a2\u30ec\u30a4\u300cClariom D\u300d\u306f\u3001\u5f93\u6765\u306e\u767a\u73fe\u89e3\u6790\u306b\u52a0\u3048\u3001\u9078\u629e\u7684\u30b9\u30d7\u30e9\u30a4\u30b7\u30f3\u30b0\u89e3\u6790\u3084long non-coding RNA (lncRNA) \u89e3\u6790\u306a\u3069\u3001\u30c8\u30e9\u30f3\u30b9\u30af\u30ea\u30d7\u30c8\u30fc\u30e0\u30ec\u30d9\u30eb\u3067\u306e\u89e3\u6790\u306b\u3082\u5a01\u529b\u3092\u767a\u63ee\u3057\u307e\u3059\u3002\u4eca\u56de\u306f\u3001Clariom D\u306e\u5727\u5012\u7684\u306a\u89e3\u6790\u6027\u80fd\u306b\u3064\u3044\u3066\u307e\u3068\u3081\u3066\u307f\u307e\u3057\u305f\u3002","og_url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/about-clariom-d\/","og_site_name":"Learning at the Bench","article_publisher":"https:\/\/www.facebook.com\/ThermoFisherJapan","article_published_time":"2017-02-07T00:00:00+00:00","article_modified_time":"2021-12-14T05:31:45+00:00","og_image":[{"width":1199,"height":630,"url":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/about-clariom-d-title.jpg","type":"image\/jpeg"}],"author":"LATB Staff","twitter_card":"summary_large_image","twitter_creator":"@ThermoFisherJP","twitter_site":"@ThermoFisherJP","twitter_misc":{"\u57f7\u7b46\u8005":"LATB Staff","\u63a8\u5b9a\u8aad\u307f\u53d6\u308a\u6642\u9593":"1\u5206"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/about-clariom-d\/#article","isPartOf":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/about-clariom-d\/"},"author":{"name":"LATB Staff","@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#\/schema\/person\/201e6a5abb838fa34e8ff0174b015d36"},"headline":"\u6b21\u4e16\u4ee3\u578b\u8d85\u9ad8\u5bc6\u5ea6\u30de\u30a4\u30af\u30ed\u30a2\u30ec\u30a4 Clariom D \u306e\u5727\u5012\u7684\u306a\u89e3\u6790\u6027\u80fd\u3068\u306f\uff1f","datePublished":"2017-02-07T00:00:00+00:00","dateModified":"2021-12-14T05:31:45+00:00","mainEntityOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/about-clariom-d\/"},"wordCount":300,"commentCount":0,"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/about-clariom-d\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/about-clariom-d-title.jpg","keywords":["\u30de\u30a4\u30af\u30ed\u30a2\u30ec\u30a4"],"articleSection":["\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023"],"inLanguage":"ja","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/about-clariom-d\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/about-clariom-d\/","url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/about-clariom-d\/","name":"\u6b21\u4e16\u4ee3\u578b\u8d85\u9ad8\u5bc6\u5ea6\u30de\u30a4\u30af\u30ed\u30a2\u30ec\u30a4 Clariom D \u306e\u5727\u5012\u7684\u306a\u89e3\u6790\u6027\u80fd\u3068\u306f\uff1f - Learning at the Bench","isPartOf":{"@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/about-clariom-d\/#primaryimage"},"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/about-clariom-d\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/about-clariom-d-title.jpg","datePublished":"2017-02-07T00:00:00+00:00","dateModified":"2021-12-14T05:31:45+00:00","author":{"@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#\/schema\/person\/201e6a5abb838fa34e8ff0174b015d36"},"breadcrumb":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/about-clariom-d\/#breadcrumb"},"inLanguage":"ja","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/about-clariom-d\/"]}]},{"@type":"ImageObject","inLanguage":"ja","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/about-clariom-d\/#primaryimage","url":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/about-clariom-d-title.jpg","contentUrl":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/about-clariom-d-title.jpg","width":1199,"height":630,"caption":"about-clariom-d-title"},{"@type":"BreadcrumbList","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/about-clariom-d\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/"},{"@type":"ListItem","position":2,"name":"\u6b21\u4e16\u4ee3\u578b\u8d85\u9ad8\u5bc6\u5ea6\u30de\u30a4\u30af\u30ed\u30a2\u30ec\u30a4 Clariom D \u306e\u5727\u5012\u7684\u306a\u89e3\u6790\u6027\u80fd\u3068\u306f\uff1f"}]},{"@type":"WebSite","@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#website","url":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/","name":"Learning at the Bench","description":"","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"ja"},{"@type":"Person","@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#\/schema\/person\/201e6a5abb838fa34e8ff0174b015d36","name":"LATB Staff","image":{"@type":"ImageObject","inLanguage":"ja","@id":"https:\/\/secure.gravatar.com\/avatar\/8803277856c8b753feb4217dff0f9953327452df1a615c3c88b2f9864efb2ddd?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/8803277856c8b753feb4217dff0f9953327452df1a615c3c88b2f9864efb2ddd?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/8803277856c8b753feb4217dff0f9953327452df1a615c3c88b2f9864efb2ddd?s=96&d=mm&r=g","caption":"LATB Staff"},"url":"https:\/\/admin.acceleratingscience.com\/author\/latbstaff\/"}]}},"taxonomy_info":{"category":[{"value":156,"label":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023"}],"post_tag":[{"value":71,"label":"\u30de\u30a4\u30af\u30ed\u30a2\u30ec\u30a4"}]},"featured_image_src_large":["https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/about-clariom-d-title-1024x538.jpg",760,399,true],"author_info":{"display_name":"LATB Staff","author_link":"https:\/\/admin.acceleratingscience.com\/author\/latbstaff\/"},"comment_info":0,"category_info":[{"term_id":156,"name":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","slug":"mol-bio","term_group":0,"term_taxonomy_id":156,"taxonomy":"category","description":"","parent":0,"count":540,"filter":"raw","meta":[],"cat_ID":156,"category_count":540,"category_description":"","cat_name":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","category_nicename":"mol-bio","category_parent":0}],"tag_info":[{"term_id":71,"name":"\u30de\u30a4\u30af\u30ed\u30a2\u30ec\u30a4","slug":"microarray","term_group":0,"term_taxonomy_id":71,"taxonomy":"post_tag","description":"","parent":0,"count":28,"filter":"raw","meta":[]}],"jetpack-related-posts":[{"id":24187,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/ngs-gene-expression-csd-ts-ion-25073\/","url_meta":{"origin":594,"position":0},"title":"\u3010\u3084\u3063\u3066\u307f\u305f\u3011\u5fae\u91cf\u30fb\u5206\u89e3RNA\u306b\u3088\u308b\u767a\u73fe\u89e3\u6790\u306e\u6700\u9069\u89e3\u306f\uff1fRNA-Seq\u3068Ion AmpliSeq Transcriptome\u3092\u6bd4\u3079\u3066\u307f\u305f","author":"LatB Staff","date":"2025\u5e7411\u670828\u65e5","format":false,"excerpt":"\u6b21\u4e16\u4ee3\u30b7\u30fc\u30b1\u30f3\u30b5\u3067\u306e\u767a\u73fe\u89e3\u6790\u306b\u53d6\u308a\u7d44\u3080\u969b\u3001RNA\u30b5\u30f3\u30d7\u30eb\u304c\u300c\u5c11\u306a\u3059\u304e\u308b\u300d\u300c\u5206\u89e3\u3057\u3066\u3044\u308b\u300d\u3068\u3044\u3046\u72b6\u6cc1\u306f\u2026","rel":"","context":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","block_context":{"text":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/mol-bio\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/11\/ngs-gene-expression-csd-ts-ion-25073_eyecatch-scaled.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/11\/ngs-gene-expression-csd-ts-ion-25073_eyecatch-scaled.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/11\/ngs-gene-expression-csd-ts-ion-25073_eyecatch-scaled.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/11\/ngs-gene-expression-csd-ts-ion-25073_eyecatch-scaled.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/11\/ngs-gene-expression-csd-ts-ion-25073_eyecatch-scaled.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/11\/ngs-gene-expression-csd-ts-ion-25073_eyecatch-scaled.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":20152,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/exosome-nucleic-acid-purification-ts-r-25017\/","url_meta":{"origin":594,"position":1},"title":"\u3010\u7b2c3\u56de\u3011\u201cRNA cargo\u201d\u306e\u7cbe\u88fd\u3068\u5b9a\u91cf\u89e3\u6790","author":"LatB Staff","date":"2026\u5e745\u670813\u65e5","format":false,"excerpt":"\u7b2c2\u56de\u3067\u306f\u3001\u57f9\u990a\u4e0a\u6e05\u3084\u3055\u307e\u3056\u307e\u306a\u4f53\u6db2\u30b5\u30f3\u30d7\u30eb\u304b\u3089\u306e\u30a8\u30af\u30bd\u30bd\u30fc\u30e0\u306e\u6fc3\u7e2e\u30fb\u56de\u53ce\u65b9\u6cd5\u306b\u3064\u3044\u3066\u7d39\u4ecb\u3057\u307e\u3057\u305f\u304c\u2026","rel":"","context":"\u305d\u306e\u4ed6","block_context":{"text":"\u305d\u306e\u4ed6","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/else\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/f17931341a23d82235760ed66ded9c41.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/f17931341a23d82235760ed66ded9c41.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/f17931341a23d82235760ed66ded9c41.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/f17931341a23d82235760ed66ded9c41.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/f17931341a23d82235760ed66ded9c41.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/f17931341a23d82235760ed66ded9c41.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":25565,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/exosome-antibody-ts-r-25068\/","url_meta":{"origin":594,"position":2},"title":"\u3010\u7b2c8\u56de\u3011\u30a8\u30af\u30bd\u30bd\u30fc\u30e0\u30b5\u30d6\u30bf\u30a4\u30d7\u306e\u5206\u753b\u6cd5 \uff1a \u30a6\u30a7\u30b9\u30bf\u30f3\u30d6\u30ed\u30c3\u30c8\uff0fqRT-PCR\uff0f\u30b7\u30fc\u30b1\u30f3\u30b9\u89e3\u6790\u306b\u9069\u3057\u305f\u5206\u753b\u65b9\u6cd5","author":"LatB Staff","date":"2026\u5e749\u670829\u65e5","format":false,"excerpt":"\u672c\u7a3f\u3067\u306f\u3001\u30a8\u30af\u30bd\u30bd\u30fc\u30e0\u819c\u4e0a\u306e\u7279\u5b9a\u306e\u30bf\u30f3\u30d1\u30af\u8cea\u3092\u6a19\u7684\u3068\u3057\u305f\u514d\u75ab\u5438\u7740\u6cd5\u306b\u57fa\u3065\u304f\u5206\u753b\u624b\u6cd5\u3092\u7d39\u4ecb\u3057\u307e\u3059\u3002\u30a8\u30af\u2026","rel":"","context":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","block_context":{"text":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/mol-bio\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25019_eyecatch.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25019_eyecatch.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25019_eyecatch.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25019_eyecatch.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25019_eyecatch.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25019_eyecatch.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":25325,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/exosome-gene-expression-ts-r-25019\/","url_meta":{"origin":594,"position":3},"title":"\u3010\u7b2c5\u56de\u3011 &#8220;RNA cargo&#8221;\u306e\u7cbe\u88fd\u3068\u5b9a\u91cf\u89e3\u6790\u300d\uff5emRNA\u306e\u5b9a\u91cf\u89e3\u6790\uff5e","author":"LatB Staff","date":"2026\u5e746\u670811\u65e5","format":false,"excerpt":"\u4eca\u56de\u306f\u3001\u30a8\u30af\u30bd\u30bd\u30fc\u30e0\uff08\u30a8\u30ad\u30bd\u30bd\u30fc\u30e0\uff09\u4e2d\u306emRNA\u306e\u5b9a\u91cf\u89e3\u6790\u306b\u3064\u3044\u3066\u8aac\u660e\u3057\u307e\u3059\u3002\u7b2c3\u56de\u3067\u30a8\u30af\u30bd\u30bd\u30fc\u30e0\u304b\u2026","rel":"","context":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","block_context":{"text":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/mol-bio\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25018_eyecatch-1.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25018_eyecatch-1.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25018_eyecatch-1.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25018_eyecatch-1.jpg?resize=700%2C400&ssl=1 2x"},"classes":[]},{"id":25247,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/exosome-gene-expression-ts-r-25018\/","url_meta":{"origin":594,"position":4},"title":"\u3010\u7b2c4\u56de\u3011&#8221;RNA cargo&#8221;\u306e\u7cbe\u88fd\u3068\u5b9a\u91cf\u89e3\u6790\uff5emiRNA\u306e\u5b9a\u91cf\u89e3\u6790\uff5e","author":"LatB Staff","date":"2026\u5e745\u670829\u65e5","format":false,"excerpt":"\u524d\u56de\uff08\u3010\u7b2c3\u56de\u3011\u201cRNA cargo\u201d\u306e\u7cbe\u88fd\u3068\u5b9a\u91cf\u89e3\u6790\uff09\u3067\u306f\u3001\u30a8\u30af\u30bd\u30bd\u30fc\u30e0 \uff08\u30a8\u30ad\u30bd\u30bd\u30fc\u30e0\uff09 \u304b\u3089\u306e\u2026","rel":"","context":"\u5206\u6790\u30fb\u6e2c\u5b9a\u95a2\u9023","block_context":{"text":"\u5206\u6790\u30fb\u6e2c\u5b9a\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/analysis\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25018_eyecatch-1.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25018_eyecatch-1.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25018_eyecatch-1.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25018_eyecatch-1.jpg?resize=700%2C400&ssl=1 2x"},"classes":[]},{"id":24953,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/ngs-gene-expression-csd-ts-ion-26011\/","url_meta":{"origin":594,"position":5},"title":"\u30e9\u30a4\u30d6\u30e9\u30ea\u30fc\u8abf\u88fd\u306e\u81ea\u52d5\u5316\u3067NGS\u306e\u53ef\u80fd\u6027\u3092\u5e83\u3052\u308b\u2015Ion Chef\u30b7\u30b9\u30c6\u30e0\u304c\u5909\u3048\u308b\u7814\u7a76\u5ba4\u306e\u30ef\u30fc\u30af\u30d5\u30ed\u30fc","author":"LatB Staff","date":"2026\u5e744\u670810\u65e5","format":false,"excerpt":"\u524d\u51e6\u7406\u306e\u81ea\u52d5\u5316\u304c\u3001NGS\u306e\u65b0\u3057\u3044\u6a19\u6e96\u3092\u3064\u304f\u308b\u6b21\u4e16\u4ee3\u30b7\u30fc\u30b1\u30f3\u30b7\u30f3\u30b0\uff08NGS\uff09\u304c\u65e5\u5e38\u7684\u306a\u7814\u7a76\u30c4\u30fc\u30eb\u3068\u306a\u3063\u2026","rel":"","context":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","block_context":{"text":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/mol-bio\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/02\/ngs-gene-expression-csd-ts-ion-26011_eyecatch.jpeg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/02\/ngs-gene-expression-csd-ts-ion-26011_eyecatch.jpeg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/02\/ngs-gene-expression-csd-ts-ion-26011_eyecatch.jpeg?resize=525%2C300&ssl=1 1.5x"},"classes":[]}],"jetpack_sharing_enabled":true,"amp_enabled":true,"jetpack_featured_media_url":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/about-clariom-d-title.jpg","_links":{"self":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/posts\/594","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/users\/988"}],"replies":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/comments?post=594"}],"version-history":[{"count":0,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/posts\/594\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/media\/3007"}],"wp:attachment":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/media?parent=594"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/categories?post=594"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/tags?post=594"},{"taxonomy":"division","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/division?post=594"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}