{"id":6146,"date":"2020-05-08T13:54:10","date_gmt":"2020-05-08T04:54:10","guid":{"rendered":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/?p=6146"},"modified":"2023-12-28T14:26:32","modified_gmt":"2023-12-28T05:26:32","slug":"solid_nebulizer_icpms_cmd_mkt","status":"publish","type":"post","link":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/solid_nebulizer_icpms_cmd_mkt\/","title":{"rendered":"\u5206\u6790\u3092\u5909\u9769\u3059\u308b\uff5e\u30bd\u30ea\u30c3\u30c9\u30cd\u30d6\u30e9\u30a4\u30b6\u30fc\u3068\u306f\u4f55\u304b"},"content":{"rendered":"<h1>\u5206\u6790\u3092\u5909\u9769\u3059\u308b\uff5e\u30bd\u30ea\u30c3\u30c9\u30cd\u30d6\u30e9\u30a4\u30b6\u30fc\u3068\u306f\u4f55\u304b<\/h1>\n<h1>\u5143\u7d20\u5206\u6790\u306e\u5909\u9077<\/h1>\n<p>\u5143\u7d20\u5206\u6790\u3092\u884c\u3046\u969b\u3001\u73fe\u5728\u4e3b\u6d41\u3068\u306a\u3063\u3066\u3044\u308b\u306e\u306fICP\u8cea\u91cf\u5206\u6790\u3067\u3059\u3002<br \/>\n\u904e\u53bb\u306b\u306f\u3001\u539f\u5b50\u5438\u5149\u6cd5\u3084ICP\u767a\u5149\u6cd5\u306a\u3069\u306e\u5206\u6790\u624b\u6cd5\u304c\u4e00\u822c\u7684\u3067\u3057\u305f\u304c\u3001ICP\u8cea\u91cf\u5206\u6790\u8a08\uff08ICP-MS\uff09\u306f\u3001\u591a\u5143\u7d20\u540c\u6642\u5206\u6790\u3092\u884c\u3046\u3053\u3068\u304c\u3067\u304d\u3001\u5206\u6790\u5bfe\u8c61\u306e\u5143\u7d20\u306e\u7a2e\u985e\u306e\u8c4a\u5bcc\u3055\u3084\u3001\u4f4e\u6fc3\u5ea6\u306e\u5143\u7d20\u3067\u3082\u5206\u6790\u304c\u3067\u304d\u308b\u3068\u3044\u3046\u5f37\u307f\u3092\u6301\u3063\u3066\u3044\u305f\u305f\u3081\u3001\u591a\u304f\u306e\u6a5f\u95a2\u3067\u4f7f\u7528\u3055\u308c\u308b\u3088\u3046\u306b\u306a\u308a\u307e\u3057\u305f\u3002<br \/>\n\u3057\u304b\u3057\u3001\u4e00\u822c\u5316\u3057\u305f\u5f53\u6642\u306eICP\u8cea\u91cf\u5206\u6790\u8a08\u306f\u591a\u304f\u306e\u5834\u5408\u3001\u6c34\u6eb6\u6db2\u8a66\u6599\u304c\u5206\u6790\u5bfe\u8c61\u3067\u3042\u308a\u3001\u5ca9\u77f3\u7b49\u306e\u56fa\u4f53\u8a66\u6599\u3092\u5206\u6790\u3059\u308b\u305f\u3081\u306b\u306f\u3001\u6eb6\u6db2\u3092\u7528\u3044\u308b\u305f\u3081\u306e\u9ad8\u5ea6\u306a\u77e5\u8b58\u3068\u6a5f\u5668\u306e\u64cd\u4f5c\u6280\u8853\u304c\u5fc5\u8981\u3067\u3042\u308a\u3001\u307e\u305f\u4e00\u5ea6\u6db2\u4f53\u5316\u3059\u308b\u305f\u3081\u306e\u624b\u9593\u304c\u304b\u304b\u308a\u3001\u5206\u6790\u306e\u8fc5\u901f\u6027\u306b\u6b20\u3051\u3066\u3044\u307e\u3057\u305f\u3002<br \/>\n\u305d\u3093\u306a\u4e2d\u3001\u767b\u5834\u3057\u305f\u306e\u304c\u30ec\u30fc\u30b6\u30fc\u30a2\u30d6\u30ec\u30fc\u30b7\u30e7\u30f3\u6cd5\u3092\u4f7f\u7528\u3057\u305fICP\u8cea\u91cf\u5206\u6790\u3067\u3059\u3002<\/p>\n<h1>\u30ec\u30fc\u30b6\u30fc\u30a2\u30d6\u30ec\u30fc\u30b7\u30e7\u30f3\u6cd5\u3068\u306f<\/h1>\n<p>\u30ec\u30fc\u30b6\u30fc\u30a2\u30d6\u30ec\u30fc\u30b7\u30e7\u30f3\u6cd5\u3068\u306f\u3001\u300c\u30ec\u30fc\u30b6\u30fc\u30a8\u30cd\u30eb\u30ae\u30fc\u306b\u3088\u308b\u56fa\u4f53\u8a66\u6599\u69cb\u6210\u5143\u7d20\u306e\u6c17\u5316\u3068\u7206\u767a\u7684\u306a\u30a8\u30a2\u30ed\u30be\u30eb\u5316\u300d\u3092\u884c\u3046\u524d\u51e6\u7406\u6cd5\u3067\u3059\u3002<br \/>\n\u56fa\u4f53\u8a66\u6599\u306b\u9ad8\u30a8\u30cd\u30eb\u30ae\u30fc\u306e\u30ec\u30fc\u30b6\u30fc\u3092\u7167\u5c04\u3059\u308b\u3068\u3001\u56fa\u4f53\u8a66\u6599\u304c\u4e00\u6c17\u306b\u52a0\u71b1\u3055\u308c\u3001\u8a66\u6599\u306e\u7206\u767a\u7684\u306a\u30a8\u30a2\u30ed\u30be\u30eb\u5316\u3068\u56fa\u4f53\u69cb\u6210\u5143\u7d20\u306e\u6c17\u5316\u304c\u767a\u751f\u3057\u307e\u3059\u3002<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" title=\"\u30ec\u30fc\u30b6\u30fc\u30a2\u30d6\u30ec\u30fc\u30b7\u30e7\u30f3\u306b\u3088\u308b\u56fa\u4f53\u8a66\u6599\u306e\u5909\u5316\" src=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2020\/05\/unnamed-file-27.jpg\" alt=\"\u30ec\u30fc\u30b6\u30fc\u30a2\u30d6\u30ec\u30fc\u30b7\u30e7\u30f3\u306b\u3088\u308b\u56fa\u4f53\u8a66\u6599\u306e\u5909\u5316\" width=\"294\" height=\"208\" \/><br \/>\n\u3053\u3046\u3057\u3066\u767a\u751f\u3057\u305f\u30a8\u30a2\u30ed\u30be\u30eb\u3092\u5206\u6790\u3059\u308b\u3053\u3068\u3067\u3001\u5fae\u91cf\u5143\u7d20\u89e3\u6790\u306a\u3069\u9ad8\u611f\u5ea6\u306a\u5206\u6790\u304c\u5fc5\u8981\u306a\u56fa\u4f53\u8a66\u6599\u306b\u3064\u3044\u3066\u3082\u5bfe\u5fdc\u3059\u308b\u3053\u3068\u304c\u3067\u304d\u308b\u3088\u3046\u306b\u306a\u3063\u305f\u306e\u3067\u3059\u3002<\/p>\n<h1>\u30ec\u30fc\u30b6\u30fc\u30a2\u30d6\u30ec\u30fc\u30b7\u30e7\u30f3\u6cd5\u306b\u304a\u3051\u308b\u30ec\u30fc\u30b6\u30fc\u306e\u7a2e\u985e<\/h1>\n<p>\u524d\u8ff0\u306e\u901a\u308a\u3001\u30ec\u30fc\u30b6\u30fc\u30a2\u30d6\u30ec\u30fc\u30b7\u30e7\u30f3\u306f\u30ec\u30fc\u30b6\u30fc\u306e\u30a8\u30cd\u30eb\u30ae\u30fc\u306b\u3088\u3063\u3066\u8a66\u6599\u3092\u30a8\u30a2\u30ed\u30be\u30eb\u5316\u30fb\u6c17\u5316\u3059\u308b\u524d\u51e6\u7406\u306e\u65b9\u6cd5\u3067\u3059\u3002<br \/>\n\u305d\u306e\u305f\u3081\u3001\u30ec\u30fc\u30b6\u30fc\u7167\u5c04\u3092\u884c\u3063\u305f\u969b\u306e\u52a0\u71b1\u306b\u3088\u308b\u8a66\u6599\u306e\u5909\u5316\u3092\u77e5\u308b\u3053\u3068\u306f\u30ec\u30fc\u30b6\u30fc\u30a2\u30d6\u30ec\u30fc\u30b7\u30e7\u30f3\u3092\u77e5\u308b\u3046\u3048\u3067\u6b20\u304b\u305b\u306a\u3044\u60c5\u5831\u3068\u3044\u3048\u307e\u3059\u3002<br \/>\n\u30ec\u30fc\u30b6\u30fc\u306b\u306f\u5927\u304d\u304f\u5206\u3051\u3066CW\u30ec\u30fc\u30b6\u30fc\uff08\u9023\u7d9a\u767a\u632f\u30ec\u30fc\u30b6\u30fc\uff09\u3068\u30d1\u30eb\u30b9\u30ec\u30fc\u30b6\u30fc\u304c\u3042\u308a\u307e\u3059\u304c\u3001\u30ec\u30fc\u30b6\u30fc\u30a2\u30d6\u30ec\u30fc\u30b7\u30e7\u30f3\u306b\u4f7f\u7528\u3055\u308c\u308b\u306e\u306f\u4e3b\u306b\u30d1\u30eb\u30b9\u30ec\u30fc\u30b6\u30fc\u3068\u306a\u308a\u307e\u3059\u3002<br \/>\n\u305d\u306e\u7406\u7531\u306f\u3001CW\u30ec\u30fc\u30b6\u30fc\u306f\u30a8\u30cd\u30eb\u30ae\u30fc\u3092\u9023\u7d9a\u7684\u306b\u7167\u5c04\u7269\u306b\u4ed8\u4e0e\u3059\u308b\u305f\u3081\u3001\u30a8\u30cd\u30eb\u30ae\u30fc\u306e\u591a\u304f\u304c\u71b1\u62e1\u6563\u306b\u3088\u3063\u3066\u5931\u308f\u308c\u3066\u3057\u307e\u3046\u305f\u3081\u3067\u3059\u3002<br \/>\n\u307e\u305f\u3001\u30d1\u30eb\u30b9\u30ec\u30fc\u30b6\u30fc\u306e\u4e2d\u3067\u3082\u6bd4\u8f03\u7684\u71b1\u62e1\u6563\u306b\u3088\u308b\u30a8\u30cd\u30eb\u30ae\u30fc\u640d\u5931\u304c\u5927\u304d\u3044\u30ca\u30ce\u79d2\u30ec\u30fc\u30b6\u30fc\u3068\u3088\u308a\u77ed\u30d1\u30eb\u30b9\u306e\u30d5\u30a7\u30e0\u30c8\u79d2\u30ec\u30fc\u30b6\u30fc\u304c\u3042\u308a\u3001\u524d\u8ff0\u306e\u71b1\u62e1\u6563\u3092\u6291\u3048\u308b\u306b\u306f\u3088\u308a\u77ed\u6642\u9593\u306e\u9593\u306b\u30a8\u30cd\u30eb\u30ae\u30fc\u3092\u7167\u5c04\u7269\u306b\u4ed8\u4e0e\u3059\u308b\u3053\u3068\u304c\u3067\u304d\u308b\u30d5\u30a7\u30e0\u30c8\u79d2\u30ec\u30fc\u30b6\u30fc\u3092\u4f7f\u7528\u3059\u308b\u3053\u3068\u304c\u6709\u52b9\u3067\u3059\u3002<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" title=\"\u30ca\u30ce\u79d2\u30ec\u30fc\u30b6\u30fc\u3068\u30d5\u30a7\u30e0\u30c8\u79d2\u30ec\u30fc\u30b6\u30fc\u306e\u9055\u3044\" src=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2020\/05\/unnamed-file-28.jpg\" alt=\"\u30ca\u30ce\u79d2\u30ec\u30fc\u30b6\u30fc\u3068\u30d5\u30a7\u30e0\u30c8\u79d2\u30ec\u30fc\u30b6\u30fc\u306e\u9055\u3044\" width=\"275\" height=\"293\" \/><\/p>\n<h1>\u30bd\u30ea\u30c3\u30c9\u30cd\u30d6\u30e9\u30a4\u30b6\u30fc\u3068\u306f<\/h1>\n<p>\u3053\u3053\u307e\u3067\u30ec\u30fc\u30b6\u30fc\u30a2\u30d6\u30ec\u30fc\u30b7\u30e7\u30f3\u3068\u306f\u4f55\u304b\u3001\u3054\u8aac\u660e\u3092\u3057\u3066\u304d\u307e\u3057\u305f\u304c\u3001\u3053\u3053\u304b\u3089\u306f\u30ec\u30fc\u30b6\u30fc\u30a2\u30d6\u30ec\u30fc\u30b7\u30e7\u30f3\u3068\u540c\u3058\u539f\u7406\u3092\u4f7f\u3063\u305f\u300c\u30bd\u30ea\u30c3\u30c9\u30cd\u30d6\u30e9\u30a4\u30b6\u30fc\u300d\u306b\u3064\u3044\u3066\u3054\u8aac\u660e\u3092\u3057\u307e\u3059\u3002<br \/>\n\u30bd\u30ea\u30c3\u30c9\u30cd\u30d6\u30e9\u30a4\u30b6\u30fc\u306f\u7aef\u7684\u306b\u8a00\u3046\u3068\u3001\u300c\u5316\u5b66\u5206\u6790\u3078\u306e\u5fdc\u7528\u3092\u91cd\u8996\u3057\u305f\u30ec\u30fc\u30b6\u30fc\u30a2\u30d6\u30ec\u30fc\u30b7\u30e7\u30f3\u300d\u3067\u3059\u3002<br \/>\n\u30ec\u30fc\u30b6\u30fc\u30a2\u30d6\u30ec\u30fc\u30b7\u30e7\u30f3\u306f\u5fae\u7d30\u52a0\u5de5\u306b\u3082\u4f7f\u308f\u308c\u308b\u306a\u3069\u3001\u6c4e\u7528\u6027\u306e\u9ad8\u3044\u6280\u8853\u3067\u3059\u304c\u8a66\u6599\u306b\u5bfe\u3059\u308b\u30a8\u30cd\u30eb\u30ae\u30fc\u306e\u4ed8\u4e0e\u304c\u5927\u304d\u3044\u305f\u3081\u3001\u71b1\u7684\u306b\u8a66\u6599\u3092\u5909\u8cea\u3055\u305b\u3066\u3057\u307e\u3063\u305f\u308a\u3001\u4fe1\u53f7\u304c\u4e0d\u5b89\u5b9a\u306b\u306a\u308b\u306a\u3069\u5206\u6790\u3092\u884c\u3046\u4e0a\u3067\u306f\u3044\u304f\u3064\u304b\u306e\u8ab2\u984c\u304c\u3042\u308a\u3001\u5206\u6790\u611f\u5ea6\u3092\u4e0b\u3052\u3066\u3057\u307e\u3046\u30c7\u30e1\u30ea\u30c3\u30c8\u304c\u3042\u308a\u307e\u3057\u305f\u3002<br \/>\n\u305d\u306e\u305f\u3081\u30bd\u30ea\u30c3\u30c9\u30cd\u30d6\u30e9\u30a4\u30b6\u30fc\u3067\u306f\u3001\u30ec\u30fc\u30b6\u30fc\u51fa\u529b\u3092\u6291\u3048\u305f\u307e\u307e\u30ec\u30fc\u30b6\u30fc\u30d1\u30eb\u30b9\u306e\u767a\u632f\u6570\u3092\u9ad8\u3081\u308b\u3053\u3068\u3067\u5206\u6790\u5143\u7d20\u306e\u4fe1\u53f7\u3092\u9ad8\u3081\u308b\u3068\u3044\u3046\u65b9\u6cd5\u3092\u4f7f\u3044\u307e\u3059\u3002\u305d\u306e\u305f\u3081\u3001\u4e0b\u8a18\u306e\u8868\u306e\u3088\u3046\u306b\u69d8\u3005\u306a\u9762\u3067\u30e1\u30ea\u30c3\u30c8\u3092\u4eab\u53d7\u3059\u308b\u3053\u3068\u304c\u3067\u304d\u307e\u3059\u3002<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" title=\"\u30ec\u30fc\u30b6\u30fc\u30a2\u30d6\u30ec\u30fc\u30b7\u30e7\u30f3\u3068\u30bd\u30ea\u30c3\u30c9\u30cd\u30d6\u30e9\u30a4\u30b6\u30fc\u306e\u9055\u3044\" src=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2020\/05\/unnamed-file-29.jpg\" alt=\"\u30ec\u30fc\u30b6\u30fc\u30a2\u30d6\u30ec\u30fc\u30b7\u30e7\u30f3\u3068\u30bd\u30ea\u30c3\u30c9\u30cd\u30d6\u30e9\u30a4\u30b6\u30fc\u306e\u9055\u3044\" width=\"528\" height=\"296\" \/><br \/>\n\u3064\u307e\u308a\u30bd\u30ea\u30c3\u30c9\u30cd\u30d6\u30e9\u30a4\u30b6\u30fc\u306f\u56fa\u4f53\u8a66\u6599\u306e\u5143\u7d20\u30fb\u540c\u4f4d\u4f53\u5206\u6790\u306b\u304a\u3044\u3066ICP-MS\u6cd5\u306e\u5206\u6790\u6027\u80fd\u3092\u6700\u5927\u9650\u306b\u5f15\u304d\u51fa\u3059\u305f\u3081\u306e\u5206\u6790\u624b\u6cd5\u306a\u306e\u3067\u3059\u3002<\/p>\n<h1>\u6700\u5f8c\u306b<\/h1>\n<p>\u3044\u304b\u304c\u3060\u3063\u305f\u3067\u3057\u3087\u3046\u304b\uff1f<br \/>\n\u56fa\u4f53\u8a66\u6599\u306e\u5206\u6790\u306b\u3064\u3044\u3066\u304a\u60a9\u307f\u306e\u65b9\u306f\u305c\u3072\u30bd\u30ea\u30c3\u30c9\u30cd\u30d6\u30e9\u30a4\u30b6\u30fc\u306b\u3088\u308b\u5206\u6790\u3092\u304a\u8a66\u3057\u3044\u305f\u3060\u3051\u308c\u3070\u3068\u601d\u3044\u307e\u3059\u3002<br \/>\n\u3088\u308a\u8a73\u7d30\u306a\u30bd\u30ea\u30c3\u30c9\u30cd\u30d6\u30e9\u30a4\u30b6\u30fc\u306e\u7279\u5fb4\u3084\u3001\u5206\u6790\u7d50\u679c\u306e\u5177\u4f53\u4f8b\u306a\u3069\u3092\u304a\u63a2\u3057\u306e\u65b9\u306f\u3001\u3053\u3061\u3089\u306e\u30ea\u30f3\u30af\u304b\u3089\u8cc7\u6599\u3092\u30c0\u30a6\u30f3\u30ed\u30fc\u30c9\u3057\u3066\u307f\u3066\u304f\u3060\u3055\u3044\u3002<\/p>\n<p><a class=\"btn btn-red\" href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/global\/forms\/industrial\/130320-solid-nebulizer.html?ICID=cmd_icp_ms_r04_jp_solid_nebulizer_icpms_cmd_mkt_Social_LAB\" target=\"_blank\" rel=\"noopener\">\u5168\u7de8\u306e\u30c0\u30a6\u30f3\u30ed\u30fc\u30c9\u306f\u3053\u3061\u3089<\/a><\/p>\n<p><iframe loading=\"lazy\" title=\"\u30bd\u30ea\u30c3\u30c9\u30cd\u30d6\u30e9\u30a4\u30b6\u30fc-ICP\u8cea\u91cf\u5206\u6790\u304c\u5b9f\u73fe\u3059\u308b\u9769\u65b0\u7684\u306a\u56fa\u4f53\u5206\u6790\u6cd5\" width=\"760\" height=\"428\" src=\"https:\/\/www.youtube.com\/embed\/ho2wnSuidgg?feature=oembed\" frameborder=\"0\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share\" allowfullscreen><\/iframe><\/p>\n<p>&nbsp;<\/p>\n<p>\u7814\u7a76\u7528\u306b\u306e\u307f\u4f7f\u7528\u3067\u304d\u307e\u3059\u3002\u8a3a\u65ad\u7528\u306b\u306f\u4f7f\u7528\u3044\u305f\u3060\u3051\u307e\u305b\u3093\u3002<\/p>\n","protected":false},"excerpt":{"rendered":"<p>\u5206\u6790\u3092\u5909\u9769\u3059\u308b\uff5e\u30bd\u30ea\u30c3\u30c9\u30cd\u30d6\u30e9\u30a4\u30b6\u30fc\u3068\u306f\u4f55\u304b \u5143\u7d20\u5206\u6790\u306e\u5909\u9077 \u5143\u7d20\u5206\u6790\u3092\u884c\u3046\u969b\u3001\u73fe\u5728\u4e3b\u6d41\u3068\u306a\u3063\u3066\u3044\u308b\u306e\u306fICP\u8cea\u91cf\u5206\u6790\u3067\u3059\u3002 \u904e\u53bb\u306b\u306f\u3001\u539f\u5b50\u5438\u5149\u6cd5\u3084ICP\u767a\u5149\u6cd5\u306a\u3069\u306e\u5206\u6790\u624b\u6cd5\u304c\u4e00\u822c\u7684\u3067\u3057\u305f\u304c\u3001ICP\u8cea\u91cf\u5206\u6790\u8a08\uff08ICP-M<\/p>\n","protected":false},"author":970,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_monsterinsights_skip_tracking":false,"_genesis_hide_title":false,"_genesis_hide_breadcrumbs":false,"_genesis_hide_singular_image":false,"_genesis_hide_footer_widgets":false,"_genesis_custom_body_class":"","_genesis_custom_post_class":"","_genesis_layout":"","_jetpack_newsletter_access":"","_jetpack_dont_email_post_to_subs":false,"_jetpack_newsletter_tier_id":0,"_jetpack_memberships_contains_paywalled_content":false,"_jetpack_feature_clip_id":0,"_jetpack_memberships_contains_paid_content":false,"footnotes":"","jetpack_post_was_ever_published":false},"categories":[157],"tags":[39],"division":[],"class_list":["post-6146","post","type-post","status-publish","format-standard","category-analysis","tag-mass-spectrometry","entry"],"_selected_authors":"","_selected_reviewers":"","acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v27.8 (Yoast SEO v27.8) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>\u5206\u6790\u3092\u5909\u9769\u3059\u308b\uff5e\u30bd\u30ea\u30c3\u30c9\u30cd\u30d6\u30e9\u30a4\u30b6\u30fc\u3068\u306f\u4f55\u304b | Learning at the Bench<\/title>\n<meta name=\"description\" content=\"\u5143\u7d20\u5206\u6790\u306b\u304a\u3044\u3066\u3001\u5f93\u6765\u306f\u56fa\u4f53\u8a66\u6599\u3092\u6db2\u4f53\u5316\u3059\u308b\u5fc5\u8981\u304c\u3042\u308a\u3001\u6eb6\u6db2\u3092\u6271\u3046\u305f\u3081\u306e\u9ad8\u5ea6\u306a\u77e5\u8b58\u3082\u4e0d\u53ef\u6b20\u3067\u3057\u305f\u3002\u30ec\u30fc\u30b6\u30fc\u30a2\u30d6\u30ec\u30fc\u30b7\u30e7\u30f3\u6cd5\u306b\u3088\u308b\u8a66\u6599\u306e\u30a8\u30a2\u30ed\u30be\u30eb\u5316\u3092\u7528\u3044\u305f\u8cea\u91cf\u5206\u6790\u3060\u3068\u3001\u6db2\u4f53\u5316\u305b\u305a\u306b\u56fa\u4f53\u8a66\u6599\u5206\u6790\u304c\u53ef\u80fd\u306b\u3002\u3055\u3089\u306b\u30bd\u30ea\u30c3\u30c9\u30cd\u30d6\u30e9\u30a4\u30b6\u30fc\u3067\u30d5\u30a7\u30e0\u30c8\u79d2\u30ec\u30fc\u30b6\u30fc\u3092\u4f7f\u7528\u3057\u3066\u56fa\u4f53\u6599\u306e\u5206\u6790\u7cbe\u5ea6\u3092\u6700\u5927\u9650\u306b\u9ad8\u3081\u308b\u3053\u3068\u304c\u3067\u304d\u307e\u3059\u3002\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/solid_nebulizer_icpms_cmd_mkt\/\" \/>\n<meta property=\"og:locale\" content=\"ja_JP\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"\u5206\u6790\u3092\u5909\u9769\u3059\u308b\uff5e\u30bd\u30ea\u30c3\u30c9\u30cd\u30d6\u30e9\u30a4\u30b6\u30fc\u3068\u306f\u4f55\u304b\" \/>\n<meta property=\"og:description\" content=\"\u5143\u7d20\u5206\u6790\u306b\u304a\u3044\u3066\u3001\u5f93\u6765\u306f\u56fa\u4f53\u8a66\u6599\u3092\u6db2\u4f53\u5316\u3059\u308b\u5fc5\u8981\u304c\u3042\u308a\u3001\u6eb6\u6db2\u3092\u6271\u3046\u305f\u3081\u306e\u9ad8\u5ea6\u306a\u77e5\u8b58\u3082\u4e0d\u53ef\u6b20\u3067\u3057\u305f\u3002\u30ec\u30fc\u30b6\u30fc\u30a2\u30d6\u30ec\u30fc\u30b7\u30e7\u30f3\u6cd5\u306b\u3088\u308b\u8a66\u6599\u306e\u30a8\u30a2\u30ed\u30be\u30eb\u5316\u3092\u7528\u3044\u305f\u8cea\u91cf\u5206\u6790\u3060\u3068\u3001\u6db2\u4f53\u5316\u305b\u305a\u306b\u56fa\u4f53\u8a66\u6599\u5206\u6790\u304c\u53ef\u80fd\u306b\u3002\u3055\u3089\u306b\u30bd\u30ea\u30c3\u30c9\u30cd\u30d6\u30e9\u30a4\u30b6\u30fc\u3067\u30d5\u30a7\u30e0\u30c8\u79d2\u30ec\u30fc\u30b6\u30fc\u3092\u4f7f\u7528\u3057\u3066\u56fa\u4f53\u6599\u306e\u5206\u6790\u7cbe\u5ea6\u3092\u6700\u5927\u9650\u306b\u9ad8\u3081\u308b\u3053\u3068\u304c\u3067\u304d\u307e\u3059\u3002\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/solid_nebulizer_icpms_cmd_mkt\/\" \/>\n<meta property=\"og:site_name\" content=\"Learning at the Bench\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/ThermoFisherJapan\" \/>\n<meta property=\"article:published_time\" content=\"2020-05-08T04:54:10+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2023-12-28T05:26:32+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2020\/05\/unnamed-file-27.jpg\" \/>\n<meta name=\"author\" content=\"adminlearningbench\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:creator\" content=\"@ThermoFisherJP\" \/>\n<meta name=\"twitter:site\" content=\"@ThermoFisherJP\" \/>\n<meta name=\"twitter:label1\" content=\"\u57f7\u7b46\u8005\" \/>\n\t<meta name=\"twitter:data1\" content=\"adminlearningbench\" \/>\n\t<meta name=\"twitter:label2\" content=\"\u63a8\u5b9a\u8aad\u307f\u53d6\u308a\u6642\u9593\" \/>\n\t<meta name=\"twitter:data2\" content=\"5\u5206\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/solid_nebulizer_icpms_cmd_mkt\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/solid_nebulizer_icpms_cmd_mkt\\\/\"},\"author\":{\"name\":\"adminlearningbench\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#\\\/schema\\\/person\\\/7260186849040041e3149632d906fe7b\"},\"headline\":\"\u5206\u6790\u3092\u5909\u9769\u3059\u308b\uff5e\u30bd\u30ea\u30c3\u30c9\u30cd\u30d6\u30e9\u30a4\u30b6\u30fc\u3068\u306f\u4f55\u304b\",\"datePublished\":\"2020-05-08T04:54:10+00:00\",\"dateModified\":\"2023-12-28T05:26:32+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/solid_nebulizer_icpms_cmd_mkt\\\/\"},\"wordCount\":18,\"commentCount\":0,\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/solid_nebulizer_icpms_cmd_mkt\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2020\\\/05\\\/unnamed-file-27.jpg\",\"keywords\":[\"\u8cea\u91cf\u5206\u6790\"],\"articleSection\":[\"\u5206\u6790\u30fb\u6e2c\u5b9a\u95a2\u9023\"],\"inLanguage\":\"ja\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/solid_nebulizer_icpms_cmd_mkt\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/solid_nebulizer_icpms_cmd_mkt\\\/\",\"url\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/solid_nebulizer_icpms_cmd_mkt\\\/\",\"name\":\"\u5206\u6790\u3092\u5909\u9769\u3059\u308b\uff5e\u30bd\u30ea\u30c3\u30c9\u30cd\u30d6\u30e9\u30a4\u30b6\u30fc\u3068\u306f\u4f55\u304b | Learning at the Bench\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/solid_nebulizer_icpms_cmd_mkt\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/solid_nebulizer_icpms_cmd_mkt\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2020\\\/05\\\/unnamed-file-27.jpg\",\"datePublished\":\"2020-05-08T04:54:10+00:00\",\"dateModified\":\"2023-12-28T05:26:32+00:00\",\"author\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#\\\/schema\\\/person\\\/7260186849040041e3149632d906fe7b\"},\"description\":\"\u5143\u7d20\u5206\u6790\u306b\u304a\u3044\u3066\u3001\u5f93\u6765\u306f\u56fa\u4f53\u8a66\u6599\u3092\u6db2\u4f53\u5316\u3059\u308b\u5fc5\u8981\u304c\u3042\u308a\u3001\u6eb6\u6db2\u3092\u6271\u3046\u305f\u3081\u306e\u9ad8\u5ea6\u306a\u77e5\u8b58\u3082\u4e0d\u53ef\u6b20\u3067\u3057\u305f\u3002\u30ec\u30fc\u30b6\u30fc\u30a2\u30d6\u30ec\u30fc\u30b7\u30e7\u30f3\u6cd5\u306b\u3088\u308b\u8a66\u6599\u306e\u30a8\u30a2\u30ed\u30be\u30eb\u5316\u3092\u7528\u3044\u305f\u8cea\u91cf\u5206\u6790\u3060\u3068\u3001\u6db2\u4f53\u5316\u305b\u305a\u306b\u56fa\u4f53\u8a66\u6599\u5206\u6790\u304c\u53ef\u80fd\u306b\u3002\u3055\u3089\u306b\u30bd\u30ea\u30c3\u30c9\u30cd\u30d6\u30e9\u30a4\u30b6\u30fc\u3067\u30d5\u30a7\u30e0\u30c8\u79d2\u30ec\u30fc\u30b6\u30fc\u3092\u4f7f\u7528\u3057\u3066\u56fa\u4f53\u6599\u306e\u5206\u6790\u7cbe\u5ea6\u3092\u6700\u5927\u9650\u306b\u9ad8\u3081\u308b\u3053\u3068\u304c\u3067\u304d\u307e\u3059\u3002\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/solid_nebulizer_icpms_cmd_mkt\\\/#breadcrumb\"},\"inLanguage\":\"ja\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/solid_nebulizer_icpms_cmd_mkt\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"ja\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/solid_nebulizer_icpms_cmd_mkt\\\/#primaryimage\",\"url\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2020\\\/05\\\/unnamed-file-27.jpg\",\"contentUrl\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2020\\\/05\\\/unnamed-file-27.jpg\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/solid_nebulizer_icpms_cmd_mkt\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"\u5206\u6790\u3092\u5909\u9769\u3059\u308b\uff5e\u30bd\u30ea\u30c3\u30c9\u30cd\u30d6\u30e9\u30a4\u30b6\u30fc\u3068\u306f\u4f55\u304b\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#website\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/\",\"name\":\"Learning at the Bench\",\"description\":\"\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"ja\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#\\\/schema\\\/person\\\/7260186849040041e3149632d906fe7b\",\"name\":\"adminlearningbench\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"ja\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/65df03e5d6664f6649a041e36f01a820e1a5d31ce133810d2d45d7e23ccb5e69?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/65df03e5d6664f6649a041e36f01a820e1a5d31ce133810d2d45d7e23ccb5e69?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/65df03e5d6664f6649a041e36f01a820e1a5d31ce133810d2d45d7e23ccb5e69?s=96&d=mm&r=g\",\"caption\":\"adminlearningbench\"},\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/author\\\/adminlearningbench\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"\u5206\u6790\u3092\u5909\u9769\u3059\u308b\uff5e\u30bd\u30ea\u30c3\u30c9\u30cd\u30d6\u30e9\u30a4\u30b6\u30fc\u3068\u306f\u4f55\u304b | Learning at the Bench","description":"\u5143\u7d20\u5206\u6790\u306b\u304a\u3044\u3066\u3001\u5f93\u6765\u306f\u56fa\u4f53\u8a66\u6599\u3092\u6db2\u4f53\u5316\u3059\u308b\u5fc5\u8981\u304c\u3042\u308a\u3001\u6eb6\u6db2\u3092\u6271\u3046\u305f\u3081\u306e\u9ad8\u5ea6\u306a\u77e5\u8b58\u3082\u4e0d\u53ef\u6b20\u3067\u3057\u305f\u3002\u30ec\u30fc\u30b6\u30fc\u30a2\u30d6\u30ec\u30fc\u30b7\u30e7\u30f3\u6cd5\u306b\u3088\u308b\u8a66\u6599\u306e\u30a8\u30a2\u30ed\u30be\u30eb\u5316\u3092\u7528\u3044\u305f\u8cea\u91cf\u5206\u6790\u3060\u3068\u3001\u6db2\u4f53\u5316\u305b\u305a\u306b\u56fa\u4f53\u8a66\u6599\u5206\u6790\u304c\u53ef\u80fd\u306b\u3002\u3055\u3089\u306b\u30bd\u30ea\u30c3\u30c9\u30cd\u30d6\u30e9\u30a4\u30b6\u30fc\u3067\u30d5\u30a7\u30e0\u30c8\u79d2\u30ec\u30fc\u30b6\u30fc\u3092\u4f7f\u7528\u3057\u3066\u56fa\u4f53\u6599\u306e\u5206\u6790\u7cbe\u5ea6\u3092\u6700\u5927\u9650\u306b\u9ad8\u3081\u308b\u3053\u3068\u304c\u3067\u304d\u307e\u3059\u3002","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/solid_nebulizer_icpms_cmd_mkt\/","og_locale":"ja_JP","og_type":"article","og_title":"\u5206\u6790\u3092\u5909\u9769\u3059\u308b\uff5e\u30bd\u30ea\u30c3\u30c9\u30cd\u30d6\u30e9\u30a4\u30b6\u30fc\u3068\u306f\u4f55\u304b","og_description":"\u5143\u7d20\u5206\u6790\u306b\u304a\u3044\u3066\u3001\u5f93\u6765\u306f\u56fa\u4f53\u8a66\u6599\u3092\u6db2\u4f53\u5316\u3059\u308b\u5fc5\u8981\u304c\u3042\u308a\u3001\u6eb6\u6db2\u3092\u6271\u3046\u305f\u3081\u306e\u9ad8\u5ea6\u306a\u77e5\u8b58\u3082\u4e0d\u53ef\u6b20\u3067\u3057\u305f\u3002\u30ec\u30fc\u30b6\u30fc\u30a2\u30d6\u30ec\u30fc\u30b7\u30e7\u30f3\u6cd5\u306b\u3088\u308b\u8a66\u6599\u306e\u30a8\u30a2\u30ed\u30be\u30eb\u5316\u3092\u7528\u3044\u305f\u8cea\u91cf\u5206\u6790\u3060\u3068\u3001\u6db2\u4f53\u5316\u305b\u305a\u306b\u56fa\u4f53\u8a66\u6599\u5206\u6790\u304c\u53ef\u80fd\u306b\u3002\u3055\u3089\u306b\u30bd\u30ea\u30c3\u30c9\u30cd\u30d6\u30e9\u30a4\u30b6\u30fc\u3067\u30d5\u30a7\u30e0\u30c8\u79d2\u30ec\u30fc\u30b6\u30fc\u3092\u4f7f\u7528\u3057\u3066\u56fa\u4f53\u6599\u306e\u5206\u6790\u7cbe\u5ea6\u3092\u6700\u5927\u9650\u306b\u9ad8\u3081\u308b\u3053\u3068\u304c\u3067\u304d\u307e\u3059\u3002","og_url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/solid_nebulizer_icpms_cmd_mkt\/","og_site_name":"Learning at the Bench","article_publisher":"https:\/\/www.facebook.com\/ThermoFisherJapan","article_published_time":"2020-05-08T04:54:10+00:00","article_modified_time":"2023-12-28T05:26:32+00:00","og_image":[{"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2020\/05\/unnamed-file-27.jpg","type":"","width":"","height":""}],"author":"adminlearningbench","twitter_card":"summary_large_image","twitter_creator":"@ThermoFisherJP","twitter_site":"@ThermoFisherJP","twitter_misc":{"\u57f7\u7b46\u8005":"adminlearningbench","\u63a8\u5b9a\u8aad\u307f\u53d6\u308a\u6642\u9593":"5\u5206"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/solid_nebulizer_icpms_cmd_mkt\/#article","isPartOf":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/solid_nebulizer_icpms_cmd_mkt\/"},"author":{"name":"adminlearningbench","@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#\/schema\/person\/7260186849040041e3149632d906fe7b"},"headline":"\u5206\u6790\u3092\u5909\u9769\u3059\u308b\uff5e\u30bd\u30ea\u30c3\u30c9\u30cd\u30d6\u30e9\u30a4\u30b6\u30fc\u3068\u306f\u4f55\u304b","datePublished":"2020-05-08T04:54:10+00:00","dateModified":"2023-12-28T05:26:32+00:00","mainEntityOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/solid_nebulizer_icpms_cmd_mkt\/"},"wordCount":18,"commentCount":0,"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/solid_nebulizer_icpms_cmd_mkt\/#primaryimage"},"thumbnailUrl":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2020\/05\/unnamed-file-27.jpg","keywords":["\u8cea\u91cf\u5206\u6790"],"articleSection":["\u5206\u6790\u30fb\u6e2c\u5b9a\u95a2\u9023"],"inLanguage":"ja","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/solid_nebulizer_icpms_cmd_mkt\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/solid_nebulizer_icpms_cmd_mkt\/","url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/solid_nebulizer_icpms_cmd_mkt\/","name":"\u5206\u6790\u3092\u5909\u9769\u3059\u308b\uff5e\u30bd\u30ea\u30c3\u30c9\u30cd\u30d6\u30e9\u30a4\u30b6\u30fc\u3068\u306f\u4f55\u304b | Learning at the Bench","isPartOf":{"@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/solid_nebulizer_icpms_cmd_mkt\/#primaryimage"},"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/solid_nebulizer_icpms_cmd_mkt\/#primaryimage"},"thumbnailUrl":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2020\/05\/unnamed-file-27.jpg","datePublished":"2020-05-08T04:54:10+00:00","dateModified":"2023-12-28T05:26:32+00:00","author":{"@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#\/schema\/person\/7260186849040041e3149632d906fe7b"},"description":"\u5143\u7d20\u5206\u6790\u306b\u304a\u3044\u3066\u3001\u5f93\u6765\u306f\u56fa\u4f53\u8a66\u6599\u3092\u6db2\u4f53\u5316\u3059\u308b\u5fc5\u8981\u304c\u3042\u308a\u3001\u6eb6\u6db2\u3092\u6271\u3046\u305f\u3081\u306e\u9ad8\u5ea6\u306a\u77e5\u8b58\u3082\u4e0d\u53ef\u6b20\u3067\u3057\u305f\u3002\u30ec\u30fc\u30b6\u30fc\u30a2\u30d6\u30ec\u30fc\u30b7\u30e7\u30f3\u6cd5\u306b\u3088\u308b\u8a66\u6599\u306e\u30a8\u30a2\u30ed\u30be\u30eb\u5316\u3092\u7528\u3044\u305f\u8cea\u91cf\u5206\u6790\u3060\u3068\u3001\u6db2\u4f53\u5316\u305b\u305a\u306b\u56fa\u4f53\u8a66\u6599\u5206\u6790\u304c\u53ef\u80fd\u306b\u3002\u3055\u3089\u306b\u30bd\u30ea\u30c3\u30c9\u30cd\u30d6\u30e9\u30a4\u30b6\u30fc\u3067\u30d5\u30a7\u30e0\u30c8\u79d2\u30ec\u30fc\u30b6\u30fc\u3092\u4f7f\u7528\u3057\u3066\u56fa\u4f53\u6599\u306e\u5206\u6790\u7cbe\u5ea6\u3092\u6700\u5927\u9650\u306b\u9ad8\u3081\u308b\u3053\u3068\u304c\u3067\u304d\u307e\u3059\u3002","breadcrumb":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/solid_nebulizer_icpms_cmd_mkt\/#breadcrumb"},"inLanguage":"ja","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/solid_nebulizer_icpms_cmd_mkt\/"]}]},{"@type":"ImageObject","inLanguage":"ja","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/solid_nebulizer_icpms_cmd_mkt\/#primaryimage","url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2020\/05\/unnamed-file-27.jpg","contentUrl":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2020\/05\/unnamed-file-27.jpg"},{"@type":"BreadcrumbList","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/solid_nebulizer_icpms_cmd_mkt\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/"},{"@type":"ListItem","position":2,"name":"\u5206\u6790\u3092\u5909\u9769\u3059\u308b\uff5e\u30bd\u30ea\u30c3\u30c9\u30cd\u30d6\u30e9\u30a4\u30b6\u30fc\u3068\u306f\u4f55\u304b"}]},{"@type":"WebSite","@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#website","url":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/","name":"Learning at the Bench","description":"","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"ja"},{"@type":"Person","@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#\/schema\/person\/7260186849040041e3149632d906fe7b","name":"adminlearningbench","image":{"@type":"ImageObject","inLanguage":"ja","@id":"https:\/\/secure.gravatar.com\/avatar\/65df03e5d6664f6649a041e36f01a820e1a5d31ce133810d2d45d7e23ccb5e69?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/65df03e5d6664f6649a041e36f01a820e1a5d31ce133810d2d45d7e23ccb5e69?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/65df03e5d6664f6649a041e36f01a820e1a5d31ce133810d2d45d7e23ccb5e69?s=96&d=mm&r=g","caption":"adminlearningbench"},"url":"https:\/\/admin.acceleratingscience.com\/author\/adminlearningbench\/"}]}},"taxonomy_info":{"category":[{"value":157,"label":"\u5206\u6790\u30fb\u6e2c\u5b9a\u95a2\u9023"}],"post_tag":[{"value":39,"label":"\u8cea\u91cf\u5206\u6790"}]},"featured_image_src_large":false,"author_info":{"display_name":"adminlearningbench","author_link":"https:\/\/admin.acceleratingscience.com\/author\/adminlearningbench\/"},"comment_info":0,"category_info":[{"term_id":157,"name":"\u5206\u6790\u30fb\u6e2c\u5b9a\u95a2\u9023","slug":"analysis","term_group":0,"term_taxonomy_id":157,"taxonomy":"category","description":"","parent":0,"count":106,"filter":"raw","meta":[],"cat_ID":157,"category_count":106,"category_description":"","cat_name":"\u5206\u6790\u30fb\u6e2c\u5b9a\u95a2\u9023","category_nicename":"analysis","category_parent":0}],"tag_info":[{"term_id":39,"name":"\u8cea\u91cf\u5206\u6790","slug":"mass-spectrometry","term_group":0,"term_taxonomy_id":39,"taxonomy":"post_tag","description":"","parent":0,"count":11,"filter":"raw","meta":[]}],"jetpack-related-posts":[{"id":24408,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/elemental-analysis-case-introduction-cmd-25076\/","url_meta":{"origin":6146,"position":0},"title":"LA-ICP-MS\u3067\u5b9f\u73fe\u3059\u308b\u7c89\u672b\u8a66\u6599\u306e\u8fc5\u901f\u30fb\u9ad8\u611f\u5ea6\u306a\u5143\u7d20\u5206\u6790","author":"LatB Staff","date":"2025\u5e7412\u670812\u65e5","format":false,"excerpt":"\u5316\u5b66\u54c1\u3084\u5de5\u696d\u6750\u6599\u306e\u539f\u6599\u3001\u304a\u3088\u3073\u4e8c\u6b21\u96fb\u6c60\u5411\u3051\u306e\u6a5f\u80fd\u6027\u6750\u6599\u306a\u3069\u3001\u7c89\u672b\u8a66\u6599\u3084\u30bb\u30e9\u30df\u30c3\u30af\u30b9\u6750\u6599\u4e2d\u306e\u5fae\u91cf\u5143\u7d20\u306e\u2026","rel":"","context":"\u5206\u6790\u30fb\u6e2c\u5b9a\u95a2\u9023","block_context":{"text":"\u5206\u6790\u30fb\u6e2c\u5b9a\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/analysis\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/12\/shutterstock_2249094135-scaled.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/12\/shutterstock_2249094135-scaled.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/12\/shutterstock_2249094135-scaled.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/12\/shutterstock_2249094135-scaled.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/12\/shutterstock_2249094135-scaled.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/12\/shutterstock_2249094135-scaled.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":24614,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/battery-manufacturing-elemental-analysis-csm-26005\/","url_meta":{"origin":6146,"position":1},"title":"\u96fb\u6c60\u30ea\u30b5\u30a4\u30af\u30eb\u306b\u304a\u3051\u308b\u5143\u7d20\u5206\u6790","author":"LatB Staff","date":"2026\u5e741\u670827\u65e5","format":false,"excerpt":"\u81ea\u52d5\u8eca\u306e\u96fb\u52d5\u5316\u3068\u518d\u751f\u53ef\u80fd\u30a8\u30cd\u30eb\u30ae\u30fc\u306e\u8caf\u8535\u80fd\u529b\u306e\u5897\u52a0\u306f\u3001\u3068\u3082\u306b\u96fb\u6c60\u306b\u5bfe\u3059\u308b\u9700\u8981\u306e\u5927\u5e45\u306a\u52a0\u901f\u3092\u3082\u305f\u3089\u3057\u3066\u2026","rel":"","context":"\u5206\u6790\u30fb\u6e2c\u5b9a\u95a2\u9023","block_context":{"text":"\u5206\u6790\u30fb\u6e2c\u5b9a\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/analysis\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/01\/battery-manufacturing-elemental-analysis-csm-26005_eyecatch.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/01\/battery-manufacturing-elemental-analysis-csm-26005_eyecatch.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/01\/battery-manufacturing-elemental-analysis-csm-26005_eyecatch.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/01\/battery-manufacturing-elemental-analysis-csm-26005_eyecatch.jpg?resize=700%2C400&ssl=1 2x"},"classes":[]},{"id":25090,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/battery-development-elemental-analysis-csm-26016\/","url_meta":{"origin":6146,"position":2},"title":"\u30ea\u30c1\u30a6\u30e0\u30a4\u30aa\u30f3\u96fb\u6c60\u88fd\u9020\uff1a\u4f7f\u7528\u3055\u308c\u308b\u5316\u5b66\u5206\u6790\u6280\u8853","author":"LatB Staff","date":"2026\u5e744\u670820\u65e5","format":false,"excerpt":"\u9ad8\u6027\u80fd\u96fb\u6c60\u306b\u5bfe\u3059\u308b\u9700\u8981\u306e\u6025\u5897\u306f\u3001\u751f\u7523\u306e\u3042\u3089\u3086\u308b\u6bb5\u968e\u306b\u304a\u3051\u308b\u5927\u898f\u6a21\u306a\u6295\u8cc7\u3092\u4fc3\u3057\u3066\u3044\u307e\u3059\u3002\u96fb\u6c60\u7814\u7a76\u304a\u3088\u3073\u2026","rel":"","context":"\u5206\u6790\u30fb\u6e2c\u5b9a\u95a2\u9023","block_context":{"text":"\u5206\u6790\u30fb\u6e2c\u5b9a\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/analysis\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/04\/battery-development-elemental-analysis-csm-26016_eyecatch.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/04\/battery-development-elemental-analysis-csm-26016_eyecatch.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/04\/battery-development-elemental-analysis-csm-26016_eyecatch.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/04\/battery-development-elemental-analysis-csm-26016_eyecatch.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/04\/battery-development-elemental-analysis-csm-26016_eyecatch.jpg?resize=1050%2C600&ssl=1 3x"},"classes":[]},{"id":24462,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/battery-development-microscopy-csm-25076\/","url_meta":{"origin":6146,"position":3},"title":"\u5168\u56fa\u4f53\u96fb\u6c60\u306e\u9769\u65b0\u3092\u652f\u3048\u308b\u5148\u7aef\u7684\u7279\u6027\u8a55\u4fa1\u6280\u8853\u306e\u63a2\u7a76","author":"LatB Staff","date":"2025\u5e7412\u670817\u65e5","format":false,"excerpt":"\u5168\u56fa\u4f53\u96fb\u6c60\u306e\u958b\u767a\u3067\u306f\u3001\u4f7f\u7528\u3055\u308c\u308b\u6750\u6599\u306e\u7406\u89e3\u3092\u6df1\u3081\u308b\u305f\u3081\u306b\u3001\u5148\u7aef\u7684\u306a\u6027\u8a55\u4fa1\u6280\u8853\u304c\u4e0d\u53ef\u6b20\u3067\u3059\u3002\u3053\u308c\u3089\u306e\u624b\u2026","rel":"","context":"\u5206\u6790\u30fb\u6e2c\u5b9a\u95a2\u9023","block_context":{"text":"\u5206\u6790\u30fb\u6e2c\u5b9a\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/analysis\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/12\/battery-development-microscopy-csm-25076_eyecatch.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/12\/battery-development-microscopy-csm-25076_eyecatch.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/12\/battery-development-microscopy-csm-25076_eyecatch.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/12\/battery-development-microscopy-csm-25076_eyecatch.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/12\/battery-development-microscopy-csm-25076_eyecatch.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/12\/battery-development-microscopy-csm-25076_eyecatch.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":25362,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/battery-development-ion-chromatography-csm-26020\/","url_meta":{"origin":6146,"position":4},"title":"IC-MS\/MS\u3092\u7528\u3044\u305f\u30ea\u30c1\u30a6\u30e0\u30a4\u30aa\u30f3\u96fb\u6c60\u8ca0\u6975\u306e\u52a3\u5316\u89e3\u6790","author":"LatB Staff","date":"2026\u5e746\u670826\u65e5","format":false,"excerpt":"\u539f\u6587\uff08\u82f1\u8a9e\uff09\uff1aExploring Lithium-Ion Battery Anode Degrada\u2026","rel":"","context":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","block_context":{"text":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/mol-bio\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/06\/battery-development-ion-chromatography-csm-26020_eyecatch.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/06\/battery-development-ion-chromatography-csm-26020_eyecatch.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/06\/battery-development-ion-chromatography-csm-26020_eyecatch.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/06\/battery-development-ion-chromatography-csm-26020_eyecatch.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/06\/battery-development-ion-chromatography-csm-26020_eyecatch.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/06\/battery-development-ion-chromatography-csm-26020_eyecatch.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":25592,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/ion-chromatography-contaminant-analysis-cmd-26024\/","url_meta":{"origin":6146,"position":5},"title":"\u5316\u7ca7\u54c1\u4e2d\u306ePFAS\u5206\u6790\u3068\u306f\uff1f\u7dcf\u6709\u6a5f\u30d5\u30c3\u7d20\uff08TOF\uff09\u6e2c\u5b9a\u306b\u3088\u308b\u30b9\u30af\u30ea\u30fc\u30cb\u30f3\u30b0\u3068\u898f\u5236\u5bfe\u5fdc","author":"LatB Staff","date":"2026\u5e749\u670810\u65e5","format":false,"excerpt":"PFAS\uff08\u6709\u6a5f\u30d5\u30c3\u7d20\u5316\u5408\u7269\uff09\u306f\u3001\u300c\u6c38\u9060\u306e\u5316\u5b66\u7269\u8cea\uff08Forever Chemicals\uff09\u300d\u3068\u3082\u547c\u3070\u308c\u3001\u2026","rel":"","context":"\u5206\u6790\u30fb\u6e2c\u5b9a\u95a2\u9023","block_context":{"text":"\u5206\u6790\u30fb\u6e2c\u5b9a\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/analysis\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/08\/ion-chromatography-contaminant-analysis-cmd-26024_eyecatch.png?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/08\/ion-chromatography-contaminant-analysis-cmd-26024_eyecatch.png?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/08\/ion-chromatography-contaminant-analysis-cmd-26024_eyecatch.png?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/08\/ion-chromatography-contaminant-analysis-cmd-26024_eyecatch.png?resize=700%2C400&ssl=1 2x"},"classes":[]}],"jetpack_sharing_enabled":true,"amp_enabled":true,"jetpack_featured_media_url":"","_links":{"self":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/posts\/6146","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/users\/970"}],"replies":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/comments?post=6146"}],"version-history":[{"count":0,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/posts\/6146\/revisions"}],"wp:attachment":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/media?parent=6146"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/categories?post=6146"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/tags?post=6146"},{"taxonomy":"division","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/division?post=6146"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}