{"id":630,"date":"2017-02-23T00:00:00","date_gmt":"2017-02-23T00:00:00","guid":{"rendered":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/qpcr-basic37\/"},"modified":"2025-04-16T15:25:35","modified_gmt":"2025-04-16T06:25:35","slug":"qpcr-basic37","status":"publish","type":"post","link":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/qpcr-basic37\/","title":{"rendered":"\u300cCt\u5024\u300d\u300c\u89e3\u96e2\u66f2\u7dda\u300d\u3063\u3066\u4f55\uff1f \u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u89e3\u6790\u3067\u7528\u3044\u3089\u308c\u308b\u7528\u8a9e\u307e\u3068\u3081"},"content":{"rendered":"<p>\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u306b\u306f\u7279\u6709\u306e\u7528\u8a9e\u304c\u983b\u51fa\u3057\u307e\u3059\u304c\u3001\u679c\u305f\u3057\u3066\u305d\u306e\u5185\u5bb9\u3092\u6b63\u3057\u304f\u7406\u89e3\u3067\u304d\u3066\u3044\u308b\u3067\u3057\u3087\u3046\u304b\uff1f\u4eca\u56de\u306f\u3001\u96e3\u89e3\u3067\u308f\u304b\u308a\u306b\u304f\u3044\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u89e3\u6790\u306b\u95a2\u3059\u308b\u4e3b\u306a\u7528\u8a9e\u306e\u5b9a\u7fa9\u3092\u3054\u7d39\u4ecb\u3057\u307e\u3059\u3002<\/p>\n<h2>\u30d9\u30fc\u30b9\u30e9\u30a4\u30f3<\/h2>\n<p><strong>\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u306b\u304a\u3051\u308b\u30d9\u30fc\u30b9\u30e9\u30a4\u30f3\u3068\u306f\u3001\u86cd\u5149\u30b7\u30b0\u30ca\u30eb\u306b\u307b\u3068\u3093\u3069\u5909\u52d5\u304c\u306a\u3044\u3001PCR\u306e\u521d\u671f\u30b5\u30a4\u30af\u30eb\uff08\u901a\u5e383\uff5e15 \u30b5\u30a4\u30af\u30eb\uff09\u306b\u304a\u3051\u308b\u30b7\u30b0\u30ca\u30eb\u30ec\u30d9\u30eb\u306e\u3053\u3068\u3092\u6307\u3057\u307e\u3059\u3002<\/strong>\u3053\u306e\u30d9\u30fc\u30b9\u30e9\u30a4\u30f3\u306e\u4f4e\u30b7\u30b0\u30ca\u30eb\u306f\u3001\u53cd\u5fdc\u306e\u30d0\u30c3\u30af\u30b0\u30e9\u30a6\u30f3\u30c9\u3042\u308b\u3044\u306f\u300c\u30ce\u30a4\u30ba\u300d\u3068\u540c\u4e00\u3067\u3042\u308b\u3068\u307f\u306a\u3059\u3053\u3068\u304c\u3067\u304d\u307e\u3059\uff08\u56f31\uff09\u3002\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u306b\u304a\u3051\u308b\u30d9\u30fc\u30b9\u30e9\u30a4\u30f3\u306f\u3001\u5897\u5e45\u66f2\u7dda\u306e\u624b\u52d5\u89e3\u6790\u307e\u305f\u306f\u81ea\u52d5\u89e3\u6790\u306b\u3088\u308a\u3001\u5404\u53cd\u5fdc\u6bce\u306b\u5b9f\u9a13\u30c7\u30fc\u30bf\u3092\u57fa\u306b\u8a2d\u5b9a\u3055\u308c\u307e\u3059\u3002\u4e0b\u8a18\u306b\u793a\u3059\u30b5\u30a4\u30af\u30eb\u5024\uff08C<sub>t<\/sub>\uff09\u3092\u6b63\u78ba\u306b\u6c7a\u5b9a\u3059\u308b\u305f\u3081\u306b\u306f\u3001\u30d9\u30fc\u30b9\u30e9\u30a4\u30f3\u3092\u6ce8\u610f\u6df1\u304f\u8a2d\u5b9a\u3059\u308b\u3053\u3068\u304c\u5fc5\u8981\u3067\u3059\u3002\u30d9\u30fc\u30b9\u30e9\u30a4\u30f3\u306e\u6c7a\u5b9a\u306b\u306f\u3001\u521d\u671f\u30b5\u30a4\u30af\u30eb\u306b\u89b3\u5bdf\u3055\u308c\u308b\u30d0\u30c3\u30af\u30b0\u30e9\u30a6\u30f3\u30c9\u3092\u6392\u9664\u3059\u308b\u305f\u3081\u306b\u5341\u5206\u306a\u30b5\u30a4\u30af\u30eb\u6570\u3092\u4f7f\u7528\u3059\u308b\u3053\u3068\u304c\u5fc5\u8981\u3067\u3059\u304c\u3001\u5897\u5e45\u30b7\u30b0\u30ca\u30eb\u304c\u30d0\u30c3\u30af\u30b0\u30e9\u30a6\u30f3\u30c9\u3092\u8d85\u3048\u59cb\u3081\u308b\u30b5\u30a4\u30af\u30eb\u3092\u542b\u307e\u306a\u3044\u3088\u3046\u306b\u3057\u307e\u3059\u3002\u7570\u306a\u308b\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u53cd\u5fdc\u307e\u305f\u306f\u5b9f\u9a13\u3092\u6bd4\u8f03\u3059\u308b\u6642\u306b\u306f\u3001\u30d9\u30fc\u30b9\u30e9\u30a4\u30f3\u3092\u5404\u53cd\u5fdc\u306b\u95a2\u3057\u3066\u540c\u4e00\u306e\u65b9\u6cd5\u3067\u8a2d\u5b9a\u3059\u308b\u3053\u3068\u304c\u5fc5\u8981\u3067\u3059\uff08\u56f31\uff09\u3002<\/p>\n<div id=\"attachment_1764\" style=\"width: 742px\" class=\"wp-caption aligncenter\"><a href=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/qpcr-basic37-fig1.png\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-1764\" class=\"size-full wp-image-1764\" src=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/qpcr-basic37-fig1.png\" alt=\"qpcr-basic37-fig1\" width=\"732\" height=\"514\" \/><\/a><p id=\"caption-attachment-1764\" class=\"wp-caption-text\">\u56f31 \u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u306e\u30d9\u30fc\u30b9\u30e9\u30a4\u30f3\u304a\u3088\u3073Threshold Line<\/p><\/div>\n<h2>Threshold Line<\/h2>\n<p><strong>\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u53cd\u5fdc\u306e\u95be\u5024\uff08Threshold Line\uff09\u306f\u3001\u7b97\u51fa\u3057\u305f\u30d9\u30fc\u30b9\u30e9\u30a4\u30f3\u30b7\u30b0\u30ca\u30eb\u306b\u5bfe\u3057\u3066\u3001\u7d71\u8a08\u5b66\u7684\u306b\u6709\u610f\u306a\u5897\u52a0\u304c\u898b\u3089\u308c\u308b\u30b7\u30b0\u30ca\u30eb\u30ec\u30d9\u30eb\u3068\u3057\u307e\u3059\uff08\u56f31\uff09<\/strong>\u3002Threshold Line \u306f\u53cd\u5fdc\u306b\u3088\u308b\u5897\u5e45\u30b7\u30b0\u30ca\u30eb\u3092\u30d0\u30c3\u30af\u30b0\u30e9\u30a6\u30f3\u30c9\u304b\u3089\u8b58\u5225\u3059\u308b\u305f\u3081\u306b\u8a2d\u5b9a\u3055\u308c\u307e\u3059\u3002\u901a\u5e38\u3001\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u88c5\u7f6e\u306e\u30bd\u30d5\u30c8\u30a6\u30a7\u30a2\u306f\u3001Threshold Line\u3092\u30d9\u30fc\u30b9\u30e9\u30a4\u30f3\u86cd\u5149\u5024\u306e\u6a19\u6e96\u504f\u5dee\u306e10 \u500d\u306e\u5024\u306b\u8a2d\u5b9a\u3057\u307e\u3059\u3002\u3057\u304b\u3057\u3001Threshold Line \u306fPCR\u306e\u6307\u6570\u95a2\u6570\u7684\u5897\u5e45\u671f\u306e\u3044\u305a\u308c\u306e\u70b9\u306b\u304a\u3044\u3066\u3082\u8a2d\u5b9a\u3059\u308b\u3053\u3068\u304c\u53ef\u80fd\u3067\u3059\u3002<\/p>\n<h2>C<sub>t<\/sub> (Threshold Cycle\uff09<\/h2>\n<p><strong>Threshold Cycle\uff08C<sub>t<\/sub>\uff09\u306f\u3001\u53cd\u5fdc\u306e\u86cd\u5149\u30b7\u30b0\u30ca\u30eb\u304cThreshold Line\u3068\u4ea4\u5dee\u3059\u308b\u6642\u70b9\u306e\u30b5\u30a4\u30af\u30eb\u6570\u3067\u3059\u3002<\/strong>C<sub>t<\/sub> \u5024\u306f\u30bf\u30fc\u30b2\u30c3\u30c8\u306e\u521d\u671f\u91cf\u306b\u53cd\u6bd4\u4f8b\u3059\u308b\u305f\u3081\u3001DNA\u306e\u521d\u671f\u30b3\u30d4\u30fc\u6570\u306e\u7b97\u51fa\u306b\u4f7f\u7528\u3067\u304d\u307e\u3059\u3002\u4f8b\u3048\u3070\u3001\u7570\u306a\u308b\u91cf\u306e\u30bf\u30fc\u30b2\u30c3\u30c8\u3092\u542b\u3080\u30b5\u30f3\u30d7\u30eb\u304b\u3089\u306e\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u7d50\u679c\u3092\u6bd4\u8f03\u3059\u308b\u5834\u5408\u30012\u500d\u306e\u521d\u671f\u91cf\u3092\u542b\u3080\u30b5\u30f3\u30d7\u30eb\u306f\u3001\u5897\u5e45\u524d\u306b\u534a\u5206\u306e\u30b3\u30d4\u30fc\u6570\u306e\u30bf\u30fc\u30b2\u30c3\u30c8\u3057\u304b\u542b\u307e\u306a\u3044\u30b5\u30f3\u30d7\u30eb\u3088\u308a\u3082C<sub>t<\/sub> \u5024\u304c1\u30b5\u30a4\u30af\u30eb\u65e9\u304f\u306a\u308a\u307e\u3059\uff08\u56f32\uff09\u3002\u3053\u308c\u306f\u4e21\u65b9\u306e\u53cd\u5fdc\u306b\u304a\u3044\u3066PCR\u52b9\u7387\u304c100%\u3067\u3042\u308b\uff08\u3059\u306a\u308f\u3061\u3001\u30b5\u30a4\u30af\u30eb\u6bce\u306b\u7523\u7269\u91cf\u304c\u6b63\u78ba\u306b2\u500d\u306b\u5897\u52a0\u3059\u308b\uff09\u3068\u4eee\u5b9a\u3057\u305f\u5834\u5408\u306e\u4f8b\u3067\u3059\u3002<\/p>\n<p>\u30c6\u30f3\u30d7\u30ec\u30fc\u30c8\u306e\u91cf\u304c\u5c11\u306a\u3044\u307b\u3069\u3001\u6709\u610f\u306a\u5897\u5e45\u304c\u898b\u3089\u308c\u308b\u30b5\u30a4\u30af\u30eb\u6570\u306e\u5024\u306f\u5927\u304d\u304f\u306a\u308a\u307e\u3059\u3002<\/p>\n<div id=\"attachment_1765\" style=\"width: 738px\" class=\"wp-caption aligncenter\"><a href=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/qpcr-basic37-fig2.png\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-1765\" class=\"size-full wp-image-1765\" src=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/qpcr-basic37-fig2.png\" alt=\"qpcr-basic37-fig2\" width=\"728\" height=\"735\" \/><\/a><p id=\"caption-attachment-1765\" class=\"wp-caption-text\">\u56f32 10\u500d\u306e\u6bb5\u968e\u5e0c\u91c8\u8a66\u6599\u306e\u5897\u5e45\u30d7\u30ed\u30c3\u30c8<\/p><\/div>\n<h2>\u691c\u91cf\u7dda<\/h2>\n<p><strong>\u65e2\u77e5\u6fc3\u5ea6\u306e\u30c6\u30f3\u30d7\u30ec\u30fc\u30c8\u306e\u6bb5\u968e\u5e0c\u91c8\u7269\u3092\u4f7f\u7528\u3057\u3066\u3001\u5b9f\u9a13\u8a66\u6599\u4e2d\u306e\u30bf\u30fc\u30b2\u30c3\u30c8\u30c6\u30f3\u30d7\u30ec\u30fc\u30c8\u306e\u521d\u671f\u958b\u59cb\u91cf\u3092\u6c7a\u5b9a\u3057\u3001\u53cd\u5fdc\u52b9\u7387\u3092\u8a55\u4fa1\u3059\u308b\u305f\u3081\u306e\u691c\u91cf\u7dda\u3092\u4f5c\u6210\u3067\u304d\u307e\u3059\uff08\u56f33\uff09<\/strong>\u3002\u6bb5\u968e\u5e0c\u91c8\u7269\u306e\u5404\u65e2\u77e5\u6fc3\u5ea6\u306e\u5bfe\u6570\uff08x\u8ef8\uff09\u3092\u305d\u306e\u6fc3\u5ea6\u306b\u304a\u3051\u308bCt \u5024\uff08y \u8ef8\uff09\u306b\u5bfe\u3057\u3066\u30d7\u30ed\u30c3\u30c8\u3057\u307e\u3059\u3002\u3053\u306e\u691c\u91cf\u7dda\u304b\u3089\u3001\u53cd\u5fdc\u306e\u52b9\u7387\u304a\u3088\u3073\u69d8\u3005\u306a\u53cd\u5fdc\u30d1\u30e9\u30e1\u30fc\u30bf\uff08\u50be\u304d\u3001y \u4ea4\u70b9\u304a\u3088\u3073\u76f8\u95a2\u4fc2\u6570\u306a\u3069\uff09\u3092\u5c0e\u304d\u51fa\u3059\u3053\u3068\u304c\u3067\u304d\u307e\u3059\u3002\u691c\u91cf\u7dda\u4f5c\u6210\u7528\u306b\u9078\u629e\u3059\u308b\u6fc3\u5ea6\u306f\u5b9f\u9a13\u8a66\u6599\u4e2d\u306b\u304a\u3044\u3066\u671f\u5f85\u3055\u308c\u308b\u30bf\u30fc\u30b2\u30c3\u30c8\u6fc3\u5ea6\u306e\u7bc4\u56f2\u3092\u30ab\u30d0\u30fc\u3059\u308b\u3053\u3068\u304c\u5fc5\u8981\u3067\u3059\u3002<\/p>\n<div id=\"attachment_1766\" style=\"width: 742px\" class=\"wp-caption aligncenter\"><a href=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/qpcr-basic37-fig3.png\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-1766\" class=\"size-full wp-image-1766\" src=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/qpcr-basic37-fig3.png\" alt=\"qpcr-basic37-fig3\" width=\"732\" height=\"506\" \/><\/a><p id=\"caption-attachment-1766\" class=\"wp-caption-text\">\u56f33 \u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u30c7\u30fc\u30bf\u306e\u691c\u91cf\u7dda\u306e\u4f8b\u3002\u691c\u91cf\u7dda\u3067\u306f\u3001\u30b5\u30a4\u30af\u30eb\u5024\uff08C<sub>t<\/sub>\uff09\u3092y \u8ef8\u3001RNA\u307e\u305f\u306fDNA\u30bf\u30fc\u30b2\u30c3\u30c8\u306e\u521d\u671f\u91cf\u3092x\u8ef8\u3068\u3057\u307e\u3059\u3002\u50be\u304d\u3001y\u8ef8\u4ea4\u70b9\u304a\u3088\u3073\u76f8\u95a2\u4fc2\u6570\u306e\u5024\u304b\u3089\u53cd\u5fdc\u306e\u6027\u80fd\u306b\u95a2\u3059\u308b\u60c5\u5831\u304c\u5f97\u3089\u308c\u307e\u3059\u3002<\/p><\/div>\n<h2>\u76f8\u95a2\u4fc2\u6570\uff08R<sup>2<\/sup>\uff09<\/h2>\n<p><strong>\u76f8\u95a2\u4fc2\u6570\u3068\u306f\u3001\u30c7\u30fc\u30bf\u304c\u3069\u306e\u7a0b\u5ea6\u691c\u91cf\u7dda\u306b\u5408\u81f4\u3057\u3066\u3044\u308b\u304b\u3092\u793a\u3059\u5024\u3067\u3059\u3002<\/strong>R<sup>2<\/sup> \u5024\u306f\u691c\u91cf\u7dda\u306e\u76f4\u7dda\u6027\u3092\u53cd\u6620\u3057\u3066\u3044\u307e\u3059\u3002\u7406\u60f3\u7684\u306b\u306fR<sup>2<\/sup>\u5024\u306f1\u3067\u3059\u304c\u3001\u4e00\u822c\u7684\u306b\u306f\u304a\u3088\u305d0.999\u304c\u6700\u3082\u826f\u597d\u306a\u6570\u5024\u3067\u3059\u3002<\/p>\n<h2>Y\u8ef8\u4ea4\u70b9<\/h2>\n<p><strong>Y\u8ef8\u4ea4\u70b9\u306f\u3001\u53cd\u5fdc\u306e\u7406\u8ad6\u7684\u691c\u51fa\u9650\u754c\u3001\u307e\u305f\u306fx\u8ef8\u3067\u8868\u3057\u305f\u30bf\u30fc\u30b2\u30c3\u30c8\u5206\u5b50\u306e\u6700\u5c0f\u30b3\u30d4\u30fc\u6570\u306b\u304a\u3044\u3066\u3001\u7d71\u8a08\u5b66\u7684\u306b\u6709\u610f\u306a\u5897\u5e45\u304c\u751f\u3058\u305f\u5834\u5408\u306b\u671f\u5f85\u3055\u308c\u308bC<sub>t<\/sub>\u5024\u3092\u8868\u3057\u307e\u3059\u3002<\/strong>PCR\u306f\u7406\u8ad6\u7684\u306b\u306f\u5358\u4e00\u30b3\u30d4\u30fc\u306e\u30bf\u30fc\u30b2\u30c3\u30c8\u3092\u691c\u51fa\u3059\u308b\u3053\u3068\u304c\u53ef\u80fd\u3067\u3059\u304c\u3001\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u5b9f\u9a13\u306b\u304a\u3044\u3066\u78ba\u5b9f\u306b\u5b9a\u91cf\u3059\u308b\u3053\u3068\u304c\u53ef\u80fd\u306a\u30bf\u30fc\u30b2\u30c3\u30c8\u306e\u6700\u5c0f\u30b3\u30d4\u30fc\u6570\u306f\u4e00\u822c\u7684\u306b2\uff5e10\u30b3\u30d4\u30fc\u3067\u3059\u3002\u3053\u306e\u305f\u3081\u3001y \u8ef8\u4ea4\u70b9\u3092\u611f\u5ea6\u3068\u3057\u3066\u76f4\u63a5\u4f7f\u7528\u3067\u304d\u307e\u305b\u3093\u304c\u3001y\u8ef8\u4ea4\u70b9\u306e\u5024\u306f\u7570\u306a\u308b\u5897\u5e45\u30b7\u30b9\u30c6\u30e0\u304a\u3088\u3073\u30bf\u30fc\u30b2\u30c3\u30c8\u9593\u306e\u6bd4\u8f03\u306b\u306f\u6709\u7528\u3068\u306a\u308b\u53ef\u80fd\u6027\u304c\u3042\u308a\u307e\u3059\u3002<\/p>\n<h2>\u6307\u6570\u95a2\u6570\u7684\u5897\u5e45\u671f<\/h2>\n<p><strong>\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u306e\u5b9a\u91cf\u306f\u3001\u5897\u5e45\u306e\u5f8c\u671f\u307e\u305f\u306f\u53cd\u5fdc\u304c\u30d7\u30e9\u30c8\u30fc\u306b\u9054\u3057\u305f\u6642\u70b9\u3067\u306f\u306a\u304f\u3001\u6307\u6570\u95a2\u6570\u7684\u5897\u5e45\u671f\u306e\u521d\u671f\u306b\u884c\u3046\u3053\u3068\u304c\u91cd\u8981\u3067\u3059\u3002<\/strong>\u6307\u6570\u95a2\u6570\u7684\u5897\u5e45\u671f\u306e\u521d\u671f\u306b\u304a\u3044\u3066\u306f\u3001\u3059\u3079\u3066\u306e\u8a66\u85ac\u304c\u307e\u3060\u904e\u5270\u306b\u5b58\u5728\u3057\u3001DNA\u30dd\u30ea\u30e1\u30e9\u30fc\u30bc\u304c\u9ad8\u6d3b\u6027\u3092\u4fdd\u3063\u3066\u304a\u308a\u3001\u5897\u5e45\u7523\u7269\u306f\u4f4e\u6fc3\u5ea6\u3067\u3042\u308b\u305f\u3081\u30d7\u30e9\u30a4\u30de\u30fc\u306e\u30a2\u30cb\u30fc\u30ea\u30f3\u30b0\u80fd\u3068\u7af6\u5408\u3059\u308b\u3053\u3068\u306f\u3042\u308a\u307e\u305b\u3093\u3002\u3053\u308c\u3089\u306e\u8981\u56e0\u3059\u3079\u3066\u304c\u3001\u3088\u308a\u6b63\u78ba\u306a\u30c7\u30fc\u30bf\u306e\u53d6\u5f97\u306b\u8ca2\u732e\u3057\u307e\u3059\u3002<\/p>\n<h2>\u50be\u304d<\/h2>\n<p><strong>\u5897\u5e45\u53cd\u5fdc\u306e\u5bfe\u6570\u76f4\u7dda\u671f\u306e\u50be\u304d\u306f\u53cd\u5fdc\u306e\u52b9\u7387\u306e\u5c3a\u5ea6\u3067\u3059\u3002<\/strong>\u6b63\u78ba\u3067\u518d\u73fe\u6027\u306e\u3042\u308b\u7d50\u679c\u3092\u5f97\u308b\u305f\u3081\u306b\u306f\u3001\u53cd\u5fdc\u306e\u52b9\u7387\u306f\u9650\u308a\u306a\u304f100%\u306b\u8fd1\u304f\u3001\u3059\u306a\u308f\u3061\u50be\u304d\u3068\u3057\u3066\u20133.32\u306b\u9650\u308a\u306a\u304f\u8fd1\u3065\u304f\u3053\u3068\u304c\u5fc5\u8981\u3067\u3059\uff08\u8a73\u7d30\u306f\u4e0b\u8a18\u306e\u52b9\u7387\u306e\u9805\u3092\u53c2\u7167\uff09\u3002<\/p>\n<h2>\u52b9\u7387<\/h2>\n<p><strong>\u6b21\u306e\u7b49\u5f0f\u304b\u3089\u3001100%\u306ePCR\u52b9\u7387\u306f\u20133.32 \u306e\u50be\u304d\u306b\u76f8\u5f53\u3057\u307e\u3059\u3002<\/strong><\/p>\n<p>\u52b9\u7387 = 10<sup>\uff08\u20131\/\u50be\u304d\uff09<\/sup>\u2013 1<\/p>\n<p>\u7406\u60f3\u7684\u306b\u306f\u3001PCR\u53cd\u5fdc\u306e\u52b9\u7387\uff08E\uff09\u306f100%\u3001\u3059\u306a\u308f\u3061\u6307\u6570\u95a2\u6570\u7684\u5897\u5e45\u671f\u306b\u304a\u3044\u3066\u30c6\u30f3\u30d7\u30ec\u30fc\u30c8\u304c\u30b5\u30a4\u30af\u30eb\u6bce\u306b2\u500d\u306b\u5897\u5e45\u3057\u307e\u3059\u3002\u3053\u306e\u305f\u3081\u5b9f\u969b\u306e\u52b9\u7387\u306f\u53cd\u5fdc\u306b\u95a2\u3059\u308b\u8cb4\u91cd\u306a\u60c5\u5831\u3092\u63d0\u4f9b\u3057\u307e\u3059\u3002\u30a2\u30f3\u30d7\u30ea\u30b3\u30f3\u306e\u9577\u3055\u3001\u4e8c\u6b21\u69cb\u9020\u304a\u3088\u3073GC\u542b\u91cf\u306a\u3069\u306e\u5b9f\u9a13\u56e0\u5b50\u306f\u52b9\u7387\u306b\u5f71\u97ff\u3092\u53ca\u307c\u3057\u307e\u3059\u3002\u4ed6\u306b\u52b9\u7387\u306b\u5f71\u97ff\u3092\u4e0e\u3048\u308b\u53ef\u80fd\u6027\u306e\u3042\u308b\u56e0\u5b50\u306b\u306f\u53cd\u5fdc\u81ea\u4f53\u306e\u30c0\u30a4\u30ca\u30df\u30c3\u30af\u30b9\u3001\u6700\u9069\u3067\u306a\u3044\u8a66\u85ac\u6fc3\u5ea6\u306e\u4f7f\u7528\u304a\u3088\u3073\u9175\u7d20\u306e\u54c1\u8cea\u306a\u3069\u304c\u542b\u307e\u308c\u3001\u52b9\u7387\u309290%\u672a\u6e80\u306b\u4f4e\u4e0b\u3055\u305b\u308b\u5834\u5408\u3082\u3042\u308a\u307e\u3059\u3002PCR\u963b\u5bb3\u7269\u8cea\u304c\u30b5\u30f3\u30d7\u30eb\u306b\u542b\u307e\u308c\u3066\u3044\u308b\u3068\u3001\u52b9\u7387\u304c110%\u3092\u8d85\u3048\u308b\u3053\u3068\u3082\u3042\u308a\u307e\u3059\u3002<strong>\u826f\u597d\u306a\u53cd\u5fdc\u3067\u306f\u52b9\u7387\u306f90%\uff5e100%\u3068\u306a\u308b\u306f\u305a\u3067\u3001\u50be\u304d\u3068\u3057\u3066\u306f\u20133.58\u304b\u3089\u20133.10 \u306e\u9593\u3067\u3059\u3002<\/strong><\/p>\n<h2>\u30c0\u30a4\u30ca\u30df\u30c3\u30af\u30ec\u30f3\u30b8<\/h2>\n<p><strong>\u30c0\u30a4\u30ca\u30df\u30c3\u30af\u30ec\u30f3\u30b8\u3068\u306f\u3001\u51fa\u767a\u7269\u8cea\u306e\u6fc3\u5ea6\u306e\u4e0a\u6607\u3068\u5897\u5e45\u7523\u7269\u306e\u6fc3\u5ea6\u306e\u4e0a\u6607\u304c\u5bfe\u5fdc\u3059\u308b\u7bc4\u56f2\u306e\u3053\u3068\u3067\u3059\u3002<\/strong>\u7406\u60f3\u7684\u306b\u306f\u3001\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u306e\u30c0\u30a4\u30ca\u30df\u30c3\u30af\u30ec\u30f3\u30b8\u306f\u3001<strong>\u30d7\u30e9\u30b9\u30df\u30c9DNA\u3067\u306f7\uff5e8\u6841\u3001cDNA\u307e\u305f\u306f\u30b2\u30ce\u30e0DNA\u3067\u306f3\uff5e4\u6841<\/strong>\u306e\u7bc4\u56f2\u3067\u3059\u3002<\/p>\n<h2>\u7d76\u5bfe\u5b9a\u91cf<\/h2>\n<p><strong>\u7d76\u5bfe\u5b9a\u91cf\u3068\u306f\u3001\u65e2\u77e5\u91cf\u306e\u8a66\u6599\u3092\u6bb5\u968e\u5e0c\u91c8\u3057\u3066\u5897\u5e45\u3057\u3001\u691c\u91cf\u7dda\u3092\u4f5c\u6210\u3059\u308b\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u3092\u6307\u3057\u307e\u3059\u3002<\/strong>\u691c\u91cf\u7dda\u3068\u306e\u6bd4\u8f03\u306b\u3088\u3063\u3066\u3001\u672a\u77e5\u306e\u8a66\u6599\u3092\u5b9a\u91cf\u3057\u307e\u3059\u3002<\/p>\n<h2>\u76f8\u5bfe\u5b9a\u91cf<\/h2>\n<p><strong>\u76f8\u5bfe\u5b9a\u91cf\u3068\u306f\u3001\u4e00\u3064\u306e\u8a66\u6599\u4e2d\uff08\u4f8b\uff1a\u51e6\u7406\u6e08\u307f\uff09\u306e\u6a19\u7684\u907a\u4f1d\u5b50\u306e\u767a\u73fe\u3092\u3001\u4ed6\u306e\u8a66\u6599\u4e2d\uff08\u4f8b\uff1a\u672a\u51e6\u7406\uff09\u306e\u540c\u4e00\u907a\u4f1d\u5b50\u306e\u767a\u73fe\u3068\u6bd4\u8f03\u3059\u308b\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u3092\u6307\u3057\u307e\u3059\u3002<\/strong>\u7d50\u679c\u306f\u3001\u51e6\u7406\u6e08\u307f\u8a66\u6599\u4e2d\u306e\u767a\u73fe\u304c\u672a\u51e6\u7406\u8a66\u6599\u4e2d\u306e\u767a\u73fe\u3068\u6bd4\u8f03\u3057\u3066\u4f55\u500d\u5909\u5316\u3057\u305f\u304b\uff08\u5897\u52a0\u307e\u305f\u306f\u6e1b\u5c11\uff09\u3067\u8868\u3055\u308c\u307e\u3059\u3002\u3053\u306e\u30bf\u30a4\u30d7\u306e\u5b9a\u91cf\u306b\u304a\u3044\u3066\u306f\u3001\u5b9f\u9a13\u306e\u3070\u3089\u3064\u304d\u88dc\u6b63\u306e\u305f\u3081\u306e\u30b3\u30f3\u30c8\u30ed\u30fc\u30eb\u3068\u3057\u3066\u3001\u5185\u5728\u6027\u30b3\u30f3\u30c8\u30ed\u30fc\u30eb\u907a\u4f1d\u5b50\uff08\u03b2\u30a2\u30af\u30c1\u30f3\u306a\u3069\uff09\u3092\u7528\u3044\u307e\u3059\u3002<\/p>\n<h2>\u89e3\u96e2\u66f2\u7dda<\/h2>\n<p><strong>\u89e3\u96e2\u66f2\u7dda\uff08\u878d\u89e3\u66f2\u7dda\uff09\u306f\u53cd\u5fdc\u6e29\u5ea6\u306e\u4e0a\u6607\u306b\u4f34\u3044\u8272\u7d20\u304c\u7d50\u5408\u3057\u305f\u4e8c\u672c\u9396DNA\uff08dsDNA\uff09\u304c\u4e00\u672c\u9396DNA\uff08ssDNA\uff09\u3078\u300c\u89e3\u96e2\u300d\u3059\u308b\u969b\u306b\u89b3\u5bdf\u3055\u308c\u308b\u86cd\u5149\u306e\u5909\u5316\u3092\u30b0\u30e9\u30d5\u5316\u3057\u305f\u3082\u306e\u3067\u3059\u3002<\/strong>\u4f8b\u3048\u3070\u3001<a href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/life-science\/pcr\/real-time-pcr\/reagents-kits\/sybr-green-master-mixes.html?CID=gsd_pcr_sbu_r04_jp_cp0000_pjt0000_gsd00000_0so_blg_op_awa_oc_s00_qpcr43_Social_LAB\" target=\"_blank\" rel=\"noopener noreferrer\">Applied Biosystems\u2122 SYBR\u2122 Green I \u8272\u7d20<\/a>\u304c\u7d50\u5408\u3057\u305f\u4e8c\u672c\u9396DNA\u3092\u52a0\u71b1\u3059\u308b\u3068\u3001\u878d\u89e3\u70b9\uff08Tm\uff09\u306b\u9054\u3057\u305f\u6642\u70b9\u3067\u3001DNA\u9396\u306e\u89e3\u96e2\u304a\u3088\u3073\u305d\u308c\u306b\u7d9a\u304f\u8272\u7d20\u306e\u653e\u51fa\u306b\u3088\u308a\u3001\u6025\u6fc0\u306a\u86cd\u5149\u306e\u6e1b\u5c11\u304c\u691c\u51fa\u3055\u308c\u307e\u3059\u3002\u86cd\u5149\u3092\u6e29\u5ea6\u306b\u5bfe\u3057\u3066\u30d7\u30ed\u30c3\u30c8\u3057\uff08\u56f34A\uff09\u3001\u7d9a\u3044\u3066\u2013\u0394F\/\u0394T\uff08\u86cd\u5149\u5909\u5316\uff0f\u6e29\u5ea6\u5909\u5316\uff09\u3092\u6e29\u5ea6\u306b\u5bfe\u3057\u3066\u30d7\u30ed\u30c3\u30c8\u3059\u308b\u3053\u3068\u306b\u3088\u308a\uff08\u56f34B\uff09\u3001\u4e8c\u672c\u9396DNA\u306e\u89e3\u96e2\u306e\u52d5\u614b\u304c\u660e\u77ad\u306b\u306a\u308a\u307e\u3059\u3002<\/p>\n<div id=\"attachment_1767\" style=\"width: 558px\" class=\"wp-caption aligncenter\"><a href=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/qpcr-basic37-fig4.png\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-1767\" class=\"size-full wp-image-1767\" src=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/qpcr-basic37-fig4.png\" alt=\"qpcr-basic37-fig4\" width=\"548\" height=\"835\" \/><\/a><p id=\"caption-attachment-1767\" class=\"wp-caption-text\">\u56f34 \uff08A\uff09\u878d\u89e3\u66f2\u7dda\u304a\u3088\u3073\uff08B\uff09-\u0394F\/\u0394T vs. \u6e29\u5ea6<\/p><\/div>\n<p><strong>\u5897\u5e45\u5f8c\u306e\u89e3\u96e2\u66f2\u7dda\u89e3\u6790\u306f\u3001\u30d7\u30e9\u30a4\u30de\u30fc\u30c0\u30a4\u30de\u30fc\u526f\u7523\u7269\u7b49\u304c\u5b58\u5728\u3059\u308b\u304b\u3069\u3046\u304bPCR\u7523\u7269\u3092\u8abf\u3079\u3001\u53cd\u5fdc\u7279\u7570\u6027\u3092\u78ba\u8a8d\u3059\u308b\u305f\u3081\u306e\u3001\u7c21\u4fbf\u3067\u660e\u77ad\u306a\u65b9\u6cd5\u3067\u3059\u3002<\/strong>\u6838\u9178\u306eTm\u306f\u3001\u7a2e\u3005\u306e\u8981\u56e0\u306e\u3046\u3061\u3001\u9396\u306e\u9577\u3055\u3001GC\u542b\u91cf\u304a\u3088\u3073\u5869\u57fa\u306e\u30df\u30b9\u30de\u30c3\u30c1\u306b\u3088\u308a\u5f71\u97ff\u3055\u308c\u308b\u305f\u3081\u3001\u591a\u304f\u306e\u5834\u5408\u878d\u89e3\u7279\u6027\u306b\u3088\u308a\u3001\u7570\u306a\u308bPCR\u7523\u7269\u3092\u8b58\u5225\u3059\u308b\u3053\u3068\u304c\u53ef\u80fd\u3067\u3059\u3002\u89e3\u96e2\u66f2\u7dda\u306b\u3088\u308b\u53cd\u5fdc\u7523\u7269\u306e\u7279\u6027\u5316\uff08\u4f8b\uff1a\u30d7\u30e9\u30a4\u30de\u30fc\u30c0\u30a4\u30de\u30fcvs.\u30a2\u30f3\u30d7\u30ea\u30b3\u30f3\uff09\u306b\u3088\u308a\u3001\u9577\u6642\u9593\u3092\u8981\u3059\u308b\u30b2\u30eb\u96fb\u6c17\u6cf3\u52d5\u306e\u5fc5\u8981\u6027\u304c\u4f4e\u6e1b\u3057\u307e\u3059\u3002<\/p>\n<p>\u56f35\u306b\u793a\u3059\u5178\u578b\u7684\u306a\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u30c7\u30fc\u30bf\u30bb\u30c3\u30c8\u306f\u3001\u3053\u308c\u307e\u3067\u3054\u7d39\u4ecb\u3057\u305f\u7528\u8a9e\u306e\u591a\u304f\u3092\u8aac\u660e\u3059\u308b\u826f\u3044\u4f8b\u3067\u3059\u3002\u56f35A\u306b\u306f\u5178\u578b\u7684\u306a\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u5897\u5e45\u30d7\u30ed\u30c3\u30c8\u304c\u793a\u3057\u3066\u3042\u308a\u307e\u3059\u3002PCR\u53cd\u5fdc\u306e\u521d\u671f\u30b5\u30a4\u30af\u30eb\u306b\u304a\u3044\u3066\u306f\u3001\u86cd\u5149\u306b\u307b\u3068\u3093\u3069\u5909\u5316\u306f\u89b3\u5bdf\u3055\u308c\u307e\u305b\u3093\u3002\u53cd\u5fdc\u304c\u9032\u3080\u306b\u3064\u308c\u3066\u3001\u86cd\u5149\u30ec\u30d9\u30eb\u306f\u30b5\u30a4\u30af\u30eb\u3054\u3068\u306b\u5897\u52a0\u3057\u59cb\u3081\u307e\u3059\u3002Threshold\u306f\u30d9\u30fc\u30b9\u30e9\u30a4\u30f3\u3088\u308a\u4e0a\u306e\u3001\u30d7\u30ed\u30c3\u30c8\u306e\u6307\u6570\u95a2\u6570\u7684\u5897\u5e45\u90e8\u5206\u306b\u8a2d\u5b9a\u3055\u308c\u307e\u3059\u3002\u3053\u306eThreshold\u3092\u7528\u3044\u3066\u3001\u30b5\u30a4\u30af\u30eb\u95be\u5024\u3001\u3059\u306a\u308f\u3061\u5404\u5897\u5e45\u53cd\u5fdc\u306eC<sub>t<\/sub> \u5024\u304c\u6c7a\u5b9a\u3055\u308c\u307e\u3059\u3002\u65e2\u77e5\u91cf\u306e\u30bf\u30fc\u30b2\u30c3\u30c8\u3092\u542b\u3080\u4e00\u9023\u306e\u53cd\u5fdc\u306eC<sub>t<\/sub> \u5024\u3092\u4f7f\u7528\u3057\u3066\u3001\u691c\u91cf\u7dda\u3092\u4f5c\u6210\u3067\u304d\u307e\u3059\u3002\u5b9a\u91cf\u306f\u672a\u77e5\u306e\u8a66\u6599\u306eC<sub>t<\/sub> \u5024\u3092\u3053\u306e\u691c\u91cf\u7dda\u3068\u6bd4\u8f03\u3059\u308b\u3053\u3068\u306b\u3088\u308a\u884c\u308f\u308c\u3001\u76f8\u5bfe\u5b9a\u91cf\u306e\u5834\u5408\u306b\u306f\u8a66\u6599\u9593\u3067\u306e\u6bd4\u8f03\u3092\u884c\u3044\u3001\u691c\u91cf\u7dda\u3092\u53cd\u5fdc\u52b9\u7387\u306e\u30c1\u30a7\u30c3\u30af\u306e\u305f\u3081\u306b\u4f7f\u7528\u3057\u307e\u3059\u3002C<sub>t<\/sub> \u5024\u306f\u30c6\u30f3\u30d7\u30ec\u30fc\u30c8\u306e\u521d\u671f\u91cf\u306b\u53cd\u6bd4\u4f8b\u3057\u3001\u30c6\u30f3\u30d7\u30ec\u30fc\u30c8\u306e\u521d\u671f\u91cf\u304c\u591a\u3044\u307b\u3069\u53cd\u5fdc\u306eC<sub>t<\/sub>\u5024\u306f\u4f4e\u304f\u306a\u308a\u307e\u3059\u3002<\/p>\n<p>\u56f35B\u306b\u306f\u3001\u5897\u5e45\u30d7\u30ed\u30c3\u30c8\u306b\u304a\u3051\u308bCt \u5024\u304b\u3089\u4f5c\u6210\u3057\u305f\u691c\u91cf\u7dda\u3092\u793a\u3057\u3066\u3044\u307e\u3059\u3002\u691c\u91cf\u7dda\u304b\u3089\u5897\u5e45\u52b9\u7387\u3001\u53cd\u5fa9\u306e\u4e00\u8cab\u6027\u304a\u3088\u3073\u53cd\u5fdc\u306e\u7406\u8ad6\u7684\u691c\u51fa\u9650\u754c\u306b\u95a2\u3059\u308b\u91cd\u8981\u306a\u60c5\u5831\u304c\u5f97\u3089\u308c\u307e\u3059\u3002<\/p>\n<div id=\"attachment_1768\" style=\"width: 468px\" class=\"wp-caption aligncenter\"><a href=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/qpcr-basic37-fig5.png\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-1768\" class=\"size-full wp-image-1768\" src=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/qpcr-basic37-fig5.png\" alt=\"qpcr-basic37-fig5\" width=\"458\" height=\"873\" \/><\/a><p id=\"caption-attachment-1768\" class=\"wp-caption-text\">\u56f35 \u5178\u578b\u7684\u306a\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u30c7\u30fc\u30bf\u30bb\u30c3\u30c8\u3002\uff08A\uff0910\u500d\u5e0c\u91c8\u6bb5\u968e\u8a66\u6599\u306e\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u5897\u5e45\u30d7\u30ed\u30c3\u30c8 \uff08B\uff09\u30c6\u30f3\u30d7\u30ec\u30fc\u30c8\u306e\u30b3\u30d4\u30fc\u6570vs.\u30b5\u30a4\u30af\u30eb\u5024\u3092\uff08C<sub>t<\/sub>\uff09\u793a\u3059\u691c\u91cf\u7dda<\/p><\/div>\n<h2>\u3010\u7121\u6599\u30c0\u30a6\u30f3\u30ed\u30fc\u30c9\u3011\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u30cf\u30f3\u30c9\u30d6\u30c3\u30af<\/h2>\n<p>\u3053\u306e\u30cf\u30f3\u30c9\u30d6\u30c3\u30af\u3067\u306f\u3001\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u306e\u7406\u8ad6\u3084\u5b9f\u9a13\u30c7\u30b6\u30a4\u30f3\u306e\u8a2d\u8a08\u306a\u3069\u3001\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u306e\u57fa\u790e\u77e5\u8b58\u304c\u63b2\u8f09\u3055\u308c\u3066\u3044\u307e\u3059\u3002\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u3092\u59cb\u3081\u305f\u3070\u304b\u308a\u306e\u65b9\u3084\u3053\u308c\u304b\u3089\u5b9f\u9a13\u3092\u8003\u3048\u3066\u3044\u308b\u65b9\u306b\u3046\u3063\u3066\u3064\u3051\u306e\u30cf\u30f3\u30c9\u30d6\u30c3\u30af\u3067\u3059\u3002PDF\u30d5\u30a1\u30a4\u30eb\u306e\u30c0\u30a6\u30f3\u30ed\u30fc\u30c9\u3092\u3054\u5e0c\u671b\u306e\u65b9\u306f\u3001\u4e0b\u8a18\u30dc\u30bf\u30f3\u3088\u308a\u304a\u7533\u3057\u8fbc\u307f\u304f\u3060\u3055\u3044\u3002<\/p>\n<p><a class=\"btn btn-red\" href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/global\/forms\/real-time-pcr-handbook-form.html?CID=gsd_pcr_sbu_r04_jp_cp0000_pjt0000_gsd00000_0so_blg_op_awa_oc_s00_qpcr43_Social_LAB\" target=\"_blank\" rel=\"noopener\">\u30c0\u30a6\u30f3\u30ed\u30fc\u30c9\u3059\u308b<\/a><\/p>\n<p>&nbsp;<\/p>\n<h2>\u3010\u7121\u6599\u516c\u958b\u4e2d\u3011\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u30c8\u30e9\u30d6\u30eb\u30b7\u30e5\u30fc\u30c6\u30a3\u30f3\u30b0<\/h2>\n<p>\u7570\u5e38\u306aS\u5b57\u72b6\u306e\u5897\u5e45\u66f2\u7dda\u3001NTC\u3067\u306e\u5897\u5e45\u691c\u51fa\u3001\u5897\u5e45\u304c\u898b\u3089\u308c\u306a\u3044\u306a\u3069\u3001\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u306e\u5b9f\u9a13\u4e2d\u306b\u56f0\u3063\u305f\u969b\u306e\u624b\u52a9\u3051\u306b\u306a\u308b\u60c5\u5831\u3092\u7d39\u4ecb\u3057\u3066\u3044\u307e\u3059\u3002PDF\u30d5\u30a1\u30a4\u30eb\u306e\u30c0\u30a6\u30f3\u30ed\u30fc\u30c9\u3092\u3054\u5e0c\u671b\u306e\u65b9\u306f\u3001\u4e0b\u8a18\u30dc\u30bf\u30f3\u3088\u308a\u304a\u7533\u3057\u8fbc\u307f\u304f\u3060\u3055\u3044\u3002<\/p>\n<p><a class=\"btn btn-red\" href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/global\/forms\/pcr-system-troubleshooting.html?CID=gsd_pcr_sbu_r04_jp_cp0000_pjt0000_gsd00000_0so_blg_op_awa_oc_s00_qpcr43_Social_LAB\" target=\"_blank\" rel=\"noopener\">\u30c0\u30a6\u30f3\u30ed\u30fc\u30c9\u3059\u308b<\/a><\/p>\n<p>&nbsp;<\/p>\n<p>\u7814\u7a76\u7528\u306b\u306e\u307f\u4f7f\u7528\u3067\u304d\u307e\u3059\u3002\u8a3a\u65ad\u7528\u306b\u306f\u4f7f\u7528\u3044\u305f\u3060\u3051\u307e\u305b\u3093\u3002<\/p>\n","protected":false},"excerpt":{"rendered":"<p>\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u306b\u306f\u7279\u6709\u306e\u7528\u8a9e\u304c\u983b\u51fa\u3057\u307e\u3059\u304c\u3001\u679c\u305f\u3057\u3066\u305d\u306e\u5185\u5bb9\u3092\u6b63\u3057\u304f\u7406\u89e3\u3067\u304d\u3066\u3044\u308b\u3067\u3057\u3087\u3046\u304b\uff1f\u4eca\u56de\u306f\u3001\u96e3\u89e3\u3067\u308f\u304b\u308a\u306b\u304f\u3044\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u89e3\u6790\u306b\u95a2\u3059\u308b\u4e3b\u306a\u7528\u8a9e\u306e\u5b9a\u7fa9\u3092\u3054\u7d39\u4ecb\u3057\u307e\u3059\u3002<\/p>\n","protected":false},"author":988,"featured_media":3070,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_monsterinsights_skip_tracking":false,"_genesis_hide_title":false,"_genesis_hide_breadcrumbs":false,"_genesis_hide_singular_image":false,"_genesis_hide_footer_widgets":false,"_genesis_custom_body_class":"","_genesis_custom_post_class":"","_genesis_layout":"","_jetpack_newsletter_access":"","_jetpack_dont_email_post_to_subs":false,"_jetpack_newsletter_tier_id":0,"_jetpack_memberships_contains_paywalled_content":false,"_jetpack_hide_featured_image":false,"_jetpack_featured_image_duplicate_dismissed":0,"_jetpack_feature_clip_id":0,"_jetpack_memberships_contains_paid_content":false,"footnotes":"","jetpack_post_was_ever_published":false},"categories":[156],"tags":[7],"division":[],"class_list":["post-630","post","type-post","status-publish","format-standard","has-post-thumbnail","category-mol-bio","tag-qpcr","entry"],"_selected_authors":"","_selected_reviewers":"","acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v28.9 (Yoast SEO v28.9) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>\u300cCt\u5024\u300d\u300c\u89e3\u96e2\u66f2\u7dda\u300d\u3063\u3066\u4f55\uff1f \u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u89e3\u6790\u3067\u7528\u3044\u3089\u308c\u308b\u7528\u8a9e\u307e\u3068\u3081 - Learning at the Bench<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/qpcr-basic37\/\" \/>\n<meta property=\"og:locale\" content=\"ja_JP\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"\u300cCt\u5024\u300d\u300c\u89e3\u96e2\u66f2\u7dda\u300d\u3063\u3066\u4f55\uff1f \u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u89e3\u6790\u3067\u7528\u3044\u3089\u308c\u308b\u7528\u8a9e\u307e\u3068\u3081\" \/>\n<meta property=\"og:description\" content=\"\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u306b\u306f\u7279\u6709\u306e\u7528\u8a9e\u304c\u983b\u51fa\u3057\u307e\u3059\u304c\u3001\u679c\u305f\u3057\u3066\u305d\u306e\u5185\u5bb9\u3092\u6b63\u3057\u304f\u7406\u89e3\u3067\u304d\u3066\u3044\u308b\u3067\u3057\u3087\u3046\u304b\uff1f\u4eca\u56de\u306f\u3001\u96e3\u89e3\u3067\u308f\u304b\u308a\u306b\u304f\u3044\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u89e3\u6790\u306b\u95a2\u3059\u308b\u4e3b\u306a\u7528\u8a9e\u306e\u5b9a\u7fa9\u3092\u3054\u7d39\u4ecb\u3057\u307e\u3059\u3002\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/qpcr-basic37\/\" \/>\n<meta property=\"og:site_name\" content=\"Learning at the Bench\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/ThermoFisherJapan\" \/>\n<meta property=\"article:published_time\" content=\"2017-02-23T00:00:00+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2025-04-16T06:25:35+00:00\" \/>\n<meta property=\"og:image\" content=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/qpcr-basic37-title.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"1200\" \/>\n\t<meta property=\"og:image:height\" content=\"630\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"LATB Staff\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:creator\" content=\"@ThermoFisherJP\" \/>\n<meta name=\"twitter:site\" content=\"@ThermoFisherJP\" \/>\n<meta name=\"twitter:label1\" content=\"\u57f7\u7b46\u8005\" \/>\n\t<meta name=\"twitter:data1\" content=\"LATB Staff\" \/>\n\t<meta name=\"twitter:label2\" content=\"\u63a8\u5b9a\u8aad\u307f\u53d6\u308a\u6642\u9593\" \/>\n\t<meta name=\"twitter:data2\" content=\"14\u5206\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/qpcr-basic37\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/qpcr-basic37\\\/\"},\"author\":{\"name\":\"LATB Staff\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#\\\/schema\\\/person\\\/201e6a5abb838fa34e8ff0174b015d36\"},\"headline\":\"\u300cCt\u5024\u300d\u300c\u89e3\u96e2\u66f2\u7dda\u300d\u3063\u3066\u4f55\uff1f \u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u89e3\u6790\u3067\u7528\u3044\u3089\u308c\u308b\u7528\u8a9e\u307e\u3068\u3081\",\"datePublished\":\"2017-02-23T00:00:00+00:00\",\"dateModified\":\"2025-04-16T06:25:35+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/qpcr-basic37\\\/\"},\"wordCount\":167,\"commentCount\":0,\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/qpcr-basic37\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2019\\\/07\\\/qpcr-basic37-title.jpg\",\"keywords\":[\"\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\"],\"articleSection\":[\"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023\"],\"inLanguage\":\"ja\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/qpcr-basic37\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/qpcr-basic37\\\/\",\"url\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/qpcr-basic37\\\/\",\"name\":\"\u300cCt\u5024\u300d\u300c\u89e3\u96e2\u66f2\u7dda\u300d\u3063\u3066\u4f55\uff1f \u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u89e3\u6790\u3067\u7528\u3044\u3089\u308c\u308b\u7528\u8a9e\u307e\u3068\u3081 - Learning at the Bench\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/qpcr-basic37\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/qpcr-basic37\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2019\\\/07\\\/qpcr-basic37-title.jpg\",\"datePublished\":\"2017-02-23T00:00:00+00:00\",\"dateModified\":\"2025-04-16T06:25:35+00:00\",\"author\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#\\\/schema\\\/person\\\/201e6a5abb838fa34e8ff0174b015d36\"},\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/qpcr-basic37\\\/#breadcrumb\"},\"inLanguage\":\"ja\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/qpcr-basic37\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"ja\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/qpcr-basic37\\\/#primaryimage\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2019\\\/07\\\/qpcr-basic37-title.jpg\",\"contentUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2019\\\/07\\\/qpcr-basic37-title.jpg\",\"width\":1200,\"height\":630,\"caption\":\"qpcr-basic37-title\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/qpcr-basic37\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"\u300cCt\u5024\u300d\u300c\u89e3\u96e2\u66f2\u7dda\u300d\u3063\u3066\u4f55\uff1f \u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u89e3\u6790\u3067\u7528\u3044\u3089\u308c\u308b\u7528\u8a9e\u307e\u3068\u3081\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#website\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/\",\"name\":\"Learning at the Bench\",\"description\":\"\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"ja\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#\\\/schema\\\/person\\\/201e6a5abb838fa34e8ff0174b015d36\",\"name\":\"LATB Staff\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"ja\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/8803277856c8b753feb4217dff0f9953327452df1a615c3c88b2f9864efb2ddd?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/8803277856c8b753feb4217dff0f9953327452df1a615c3c88b2f9864efb2ddd?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/8803277856c8b753feb4217dff0f9953327452df1a615c3c88b2f9864efb2ddd?s=96&d=mm&r=g\",\"caption\":\"LATB Staff\"},\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/author\\\/latbstaff\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"\u300cCt\u5024\u300d\u300c\u89e3\u96e2\u66f2\u7dda\u300d\u3063\u3066\u4f55\uff1f \u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u89e3\u6790\u3067\u7528\u3044\u3089\u308c\u308b\u7528\u8a9e\u307e\u3068\u3081 - Learning at the Bench","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/qpcr-basic37\/","og_locale":"ja_JP","og_type":"article","og_title":"\u300cCt\u5024\u300d\u300c\u89e3\u96e2\u66f2\u7dda\u300d\u3063\u3066\u4f55\uff1f \u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u89e3\u6790\u3067\u7528\u3044\u3089\u308c\u308b\u7528\u8a9e\u307e\u3068\u3081","og_description":"\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u306b\u306f\u7279\u6709\u306e\u7528\u8a9e\u304c\u983b\u51fa\u3057\u307e\u3059\u304c\u3001\u679c\u305f\u3057\u3066\u305d\u306e\u5185\u5bb9\u3092\u6b63\u3057\u304f\u7406\u89e3\u3067\u304d\u3066\u3044\u308b\u3067\u3057\u3087\u3046\u304b\uff1f\u4eca\u56de\u306f\u3001\u96e3\u89e3\u3067\u308f\u304b\u308a\u306b\u304f\u3044\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u89e3\u6790\u306b\u95a2\u3059\u308b\u4e3b\u306a\u7528\u8a9e\u306e\u5b9a\u7fa9\u3092\u3054\u7d39\u4ecb\u3057\u307e\u3059\u3002","og_url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/qpcr-basic37\/","og_site_name":"Learning at the Bench","article_publisher":"https:\/\/www.facebook.com\/ThermoFisherJapan","article_published_time":"2017-02-23T00:00:00+00:00","article_modified_time":"2025-04-16T06:25:35+00:00","og_image":[{"width":1200,"height":630,"url":"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/qpcr-basic37-title.jpg","type":"image\/jpeg"}],"author":"LATB Staff","twitter_card":"summary_large_image","twitter_creator":"@ThermoFisherJP","twitter_site":"@ThermoFisherJP","twitter_misc":{"\u57f7\u7b46\u8005":"LATB Staff","\u63a8\u5b9a\u8aad\u307f\u53d6\u308a\u6642\u9593":"14\u5206"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/qpcr-basic37\/#article","isPartOf":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/qpcr-basic37\/"},"author":{"name":"LATB Staff","@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#\/schema\/person\/201e6a5abb838fa34e8ff0174b015d36"},"headline":"\u300cCt\u5024\u300d\u300c\u89e3\u96e2\u66f2\u7dda\u300d\u3063\u3066\u4f55\uff1f \u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u89e3\u6790\u3067\u7528\u3044\u3089\u308c\u308b\u7528\u8a9e\u307e\u3068\u3081","datePublished":"2017-02-23T00:00:00+00:00","dateModified":"2025-04-16T06:25:35+00:00","mainEntityOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/qpcr-basic37\/"},"wordCount":167,"commentCount":0,"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/qpcr-basic37\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/qpcr-basic37-title.jpg","keywords":["\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR"],"articleSection":["\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023"],"inLanguage":"ja","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/qpcr-basic37\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/qpcr-basic37\/","url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/qpcr-basic37\/","name":"\u300cCt\u5024\u300d\u300c\u89e3\u96e2\u66f2\u7dda\u300d\u3063\u3066\u4f55\uff1f \u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u89e3\u6790\u3067\u7528\u3044\u3089\u308c\u308b\u7528\u8a9e\u307e\u3068\u3081 - Learning at the Bench","isPartOf":{"@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/qpcr-basic37\/#primaryimage"},"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/qpcr-basic37\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/qpcr-basic37-title.jpg","datePublished":"2017-02-23T00:00:00+00:00","dateModified":"2025-04-16T06:25:35+00:00","author":{"@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#\/schema\/person\/201e6a5abb838fa34e8ff0174b015d36"},"breadcrumb":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/qpcr-basic37\/#breadcrumb"},"inLanguage":"ja","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/qpcr-basic37\/"]}]},{"@type":"ImageObject","inLanguage":"ja","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/qpcr-basic37\/#primaryimage","url":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/qpcr-basic37-title.jpg","contentUrl":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/qpcr-basic37-title.jpg","width":1200,"height":630,"caption":"qpcr-basic37-title"},{"@type":"BreadcrumbList","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/qpcr-basic37\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/"},{"@type":"ListItem","position":2,"name":"\u300cCt\u5024\u300d\u300c\u89e3\u96e2\u66f2\u7dda\u300d\u3063\u3066\u4f55\uff1f \u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u89e3\u6790\u3067\u7528\u3044\u3089\u308c\u308b\u7528\u8a9e\u307e\u3068\u3081"}]},{"@type":"WebSite","@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#website","url":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/","name":"Learning at the Bench","description":"","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"ja"},{"@type":"Person","@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#\/schema\/person\/201e6a5abb838fa34e8ff0174b015d36","name":"LATB Staff","image":{"@type":"ImageObject","inLanguage":"ja","@id":"https:\/\/secure.gravatar.com\/avatar\/8803277856c8b753feb4217dff0f9953327452df1a615c3c88b2f9864efb2ddd?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/8803277856c8b753feb4217dff0f9953327452df1a615c3c88b2f9864efb2ddd?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/8803277856c8b753feb4217dff0f9953327452df1a615c3c88b2f9864efb2ddd?s=96&d=mm&r=g","caption":"LATB Staff"},"url":"https:\/\/admin.acceleratingscience.com\/author\/latbstaff\/"}]}},"taxonomy_info":{"category":[{"value":156,"label":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023"}],"post_tag":[{"value":7,"label":"\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR"}]},"featured_image_src_large":["https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/qpcr-basic37-title-1024x538.jpg",760,399,true],"author_info":{"display_name":"LATB Staff","author_link":"https:\/\/admin.acceleratingscience.com\/author\/latbstaff\/"},"comment_info":0,"category_info":[{"term_id":156,"name":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","slug":"mol-bio","term_group":0,"term_taxonomy_id":156,"taxonomy":"category","description":"","parent":0,"count":540,"filter":"raw","meta":[],"cat_ID":156,"category_count":540,"category_description":"","cat_name":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","category_nicename":"mol-bio","category_parent":0}],"tag_info":[{"term_id":7,"name":"\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR","slug":"qpcr","term_group":0,"term_taxonomy_id":7,"taxonomy":"post_tag","description":"","parent":0,"count":91,"filter":"raw","meta":[]}],"jetpack-related-posts":[{"id":25247,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/exosome-gene-expression-ts-r-25018\/","url_meta":{"origin":630,"position":0},"title":"\u3010\u7b2c4\u56de\u3011&#8221;RNA cargo&#8221;\u306e\u7cbe\u88fd\u3068\u5b9a\u91cf\u89e3\u6790\uff5emiRNA\u306e\u5b9a\u91cf\u89e3\u6790\uff5e","author":"LatB Staff","date":"2026\u5e745\u670829\u65e5","format":false,"excerpt":"\u524d\u56de\uff08\u3010\u7b2c3\u56de\u3011\u201cRNA cargo\u201d\u306e\u7cbe\u88fd\u3068\u5b9a\u91cf\u89e3\u6790\uff09\u3067\u306f\u3001\u30a8\u30af\u30bd\u30bd\u30fc\u30e0 \uff08\u30a8\u30ad\u30bd\u30bd\u30fc\u30e0\uff09 \u304b\u3089\u306e\u2026","rel":"","context":"\u5206\u6790\u30fb\u6e2c\u5b9a\u95a2\u9023","block_context":{"text":"\u5206\u6790\u30fb\u6e2c\u5b9a\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/analysis\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25018_eyecatch-1.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25018_eyecatch-1.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25018_eyecatch-1.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25018_eyecatch-1.jpg?resize=700%2C400&ssl=1 2x"},"classes":[]},{"id":25325,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/exosome-gene-expression-ts-r-25019\/","url_meta":{"origin":630,"position":1},"title":"\u3010\u7b2c5\u56de\u3011 &#8220;RNA cargo&#8221;\u306e\u7cbe\u88fd\u3068\u5b9a\u91cf\u89e3\u6790\u300d\uff5emRNA\u306e\u5b9a\u91cf\u89e3\u6790\uff5e","author":"LatB Staff","date":"2026\u5e746\u670811\u65e5","format":false,"excerpt":"\u4eca\u56de\u306f\u3001\u30a8\u30af\u30bd\u30bd\u30fc\u30e0\uff08\u30a8\u30ad\u30bd\u30bd\u30fc\u30e0\uff09\u4e2d\u306emRNA\u306e\u5b9a\u91cf\u89e3\u6790\u306b\u3064\u3044\u3066\u8aac\u660e\u3057\u307e\u3059\u3002\u7b2c3\u56de\u3067\u30a8\u30af\u30bd\u30bd\u30fc\u30e0\u304b\u2026","rel":"","context":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","block_context":{"text":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/mol-bio\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25018_eyecatch-1.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25018_eyecatch-1.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25018_eyecatch-1.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25018_eyecatch-1.jpg?resize=700%2C400&ssl=1 2x"},"classes":[]},{"id":24545,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/digital-pcr-gene-expression-gsd-ts-sd-25082\/","url_meta":{"origin":630,"position":2},"title":"\u3010Absolute Q\u30c7\u30b8\u30bf\u30ebPCR\u30b7\u30b9\u30c6\u30e0\u306e\u6d3b\u7528\u4f8b\u3011\u30df\u30c8\u30b3\u30f3\u30c9\u30ea\u30a2DNA\u306e\u5b9a\u91cf","author":"LatB Staff","date":"2026\u5e741\u670816\u65e5","format":false,"excerpt":"Applied Biosystems\u2122 QuantStudio\u2122 Absolute Q\u2122 \u30c7\u30b8\u30bf\u30ebP\u2026","rel":"","context":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","block_context":{"text":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/mol-bio\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/12\/digital-pcr-gene-expression-gsd-ts-sd-25082_eyecatch.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/12\/digital-pcr-gene-expression-gsd-ts-sd-25082_eyecatch.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/12\/digital-pcr-gene-expression-gsd-ts-sd-25082_eyecatch.jpg?resize=525%2C300&ssl=1 1.5x"},"classes":[]},{"id":25565,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/exosome-antibody-ts-r-25068\/","url_meta":{"origin":630,"position":3},"title":"\u3010\u7b2c8\u56de\u3011\u30a8\u30af\u30bd\u30bd\u30fc\u30e0\u30b5\u30d6\u30bf\u30a4\u30d7\u306e\u5206\u753b\u6cd5 \uff1a \u30a6\u30a7\u30b9\u30bf\u30f3\u30d6\u30ed\u30c3\u30c8\uff0fqRT-PCR\uff0f\u30b7\u30fc\u30b1\u30f3\u30b9\u89e3\u6790\u306b\u9069\u3057\u305f\u5206\u753b\u65b9\u6cd5","author":"LatB Staff","date":"2026\u5e749\u670829\u65e5","format":false,"excerpt":"\u672c\u7a3f\u3067\u306f\u3001\u30a8\u30af\u30bd\u30bd\u30fc\u30e0\u819c\u4e0a\u306e\u7279\u5b9a\u306e\u30bf\u30f3\u30d1\u30af\u8cea\u3092\u6a19\u7684\u3068\u3057\u305f\u514d\u75ab\u5438\u7740\u6cd5\u306b\u57fa\u3065\u304f\u5206\u753b\u624b\u6cd5\u3092\u7d39\u4ecb\u3057\u307e\u3059\u3002\u30a8\u30af\u2026","rel":"","context":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","block_context":{"text":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/mol-bio\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25019_eyecatch.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25019_eyecatch.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25019_eyecatch.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25019_eyecatch.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25019_eyecatch.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25019_eyecatch.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":20152,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/exosome-nucleic-acid-purification-ts-r-25017\/","url_meta":{"origin":630,"position":4},"title":"\u3010\u7b2c3\u56de\u3011\u201cRNA cargo\u201d\u306e\u7cbe\u88fd\u3068\u5b9a\u91cf\u89e3\u6790","author":"LatB Staff","date":"2026\u5e745\u670813\u65e5","format":false,"excerpt":"\u7b2c2\u56de\u3067\u306f\u3001\u57f9\u990a\u4e0a\u6e05\u3084\u3055\u307e\u3056\u307e\u306a\u4f53\u6db2\u30b5\u30f3\u30d7\u30eb\u304b\u3089\u306e\u30a8\u30af\u30bd\u30bd\u30fc\u30e0\u306e\u6fc3\u7e2e\u30fb\u56de\u53ce\u65b9\u6cd5\u306b\u3064\u3044\u3066\u7d39\u4ecb\u3057\u307e\u3057\u305f\u304c\u2026","rel":"","context":"\u305d\u306e\u4ed6","block_context":{"text":"\u305d\u306e\u4ed6","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/else\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/f17931341a23d82235760ed66ded9c41.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/f17931341a23d82235760ed66ded9c41.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/f17931341a23d82235760ed66ded9c41.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/f17931341a23d82235760ed66ded9c41.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/f17931341a23d82235760ed66ded9c41.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/f17931341a23d82235760ed66ded9c41.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":25121,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/elisa-nucleic-acid-purification-bid-ts-mbr-26017\/","url_meta":{"origin":630,"position":5},"title":"\u3044\u307e\u3055\u3089\u805e\u3051\u306a\u30444PL\u306e\u57fa\u672c\uff1a4\u30d1\u30e9\u30e1\u30fc\u30bf\u30fc\u30ed\u30b8\u30b9\u30c6\u30a3\u30c3\u30af\u3092\u308f\u304b\u308a\u3084\u3059\u304f\u89e3\u8aac","author":"LATB Staff","date":"2026\u5e745\u67087\u65e5","format":false,"excerpt":"ELISA\u306e\u691c\u91cf\u7dda\u3084\u7528\u91cf\u53cd\u5fdc\u66f2\u7dda\u3092\u4f5c\u6210\u3059\u308b\u3068\u304d\u306b\u30014\u30d1\u30e9\u30e1\u30fc\u30bf\u30fc\u30ed\u30b8\u30b9\u30c6\u30a3\u30c3\u30af\uff084PL\uff09\u30e2\u30c7\u30eb\u3092\u4f7f\u7528\u2026","rel":"","context":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","block_context":{"text":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/mol-bio\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/04\/elisa-nucleic-acid-purification-bid-ts-mbr-26017_eyecatch-1-scaled.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/04\/elisa-nucleic-acid-purification-bid-ts-mbr-26017_eyecatch-1-scaled.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/04\/elisa-nucleic-acid-purification-bid-ts-mbr-26017_eyecatch-1-scaled.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/04\/elisa-nucleic-acid-purification-bid-ts-mbr-26017_eyecatch-1-scaled.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/04\/elisa-nucleic-acid-purification-bid-ts-mbr-26017_eyecatch-1-scaled.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/04\/elisa-nucleic-acid-purification-bid-ts-mbr-26017_eyecatch-1-scaled.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]}],"jetpack_sharing_enabled":true,"amp_enabled":true,"jetpack_featured_media_url":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/qpcr-basic37-title.jpg","_links":{"self":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/posts\/630","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/users\/988"}],"replies":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/comments?post=630"}],"version-history":[{"count":0,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/posts\/630\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/media\/3070"}],"wp:attachment":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/media?parent=630"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/categories?post=630"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/tags?post=630"},{"taxonomy":"division","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/division?post=630"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}