{"id":6305,"date":"2020-05-27T09:21:36","date_gmt":"2020-05-27T00:21:36","guid":{"rendered":"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/?p=6305"},"modified":"2024-09-18T17:20:53","modified_gmt":"2024-09-18T08:20:53","slug":"seqstudio_ce_gsd_ts_1","status":"publish","type":"post","link":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/seqstudio_ce_gsd_ts_1\/","title":{"rendered":"\u30e1\u30f3\u30c6\u30ca\u30f3\u30b9\u304c\u307b\u3068\u3093\u3069\u3044\u3089\u306a\u3044\u30b7\u30fc\u30b1\u30f3\u30b5\u30fc\uff01\uff1fSeqStudio\u3063\u3066\u3069\u3093\u306a\u88c5\u7f6e\uff1f"},"content":{"rendered":"<div id=\"attachment_6306\" style=\"width: 310px\" class=\"wp-caption alignright\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-6306\" class=\"size-medium wp-image-6306\" src=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2020\/04\/cb61dab8d2d388a32a533c85bc1c8200-300x277.jpg\" alt=\"\" width=\"300\" height=\"277\" srcset=\"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2020\/04\/cb61dab8d2d388a32a533c85bc1c8200-300x277.jpg 300w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2020\/04\/cb61dab8d2d388a32a533c85bc1c8200.jpg 650w\" sizes=\"auto, (max-width: 300px) 100vw, 300px\" \/><p id=\"caption-attachment-6306\" class=\"wp-caption-text\">\u56f31\uff1aSeqStudio Genetic Analyzer<\/p><\/div>\n<p>\u907a\u4f1d\u5b50\u89e3\u6790\u306e\u57fa\u672c\u624b\u6bb5\u306e\u4e00\u3064\u306f\u3001DNA\u306e\u5869\u57fa\u914d\u5217\u3092\u6c7a\u5b9a\u3059\u308b\u3053\u3068\uff08DNA\u30b7\u30fc\u30b1\u30f3\u30b7\u30f3\u30b0\uff09\u3067\u3059\u3002\u73fe\u5728\u306f\u30ad\u30e3\u30d4\u30e9\u30ea\u30fc\u96fb\u6c17\u6cf3\u52d5\u30b7\u30b9\u30c6\u30e0\u3092\u7528\u3044\u305f\u30b7\u30fc\u30b1\u30f3\u30b5\u30fc\u3067\u306e\u89e3\u6790\u304c\u4e3b\u6d41\u3067\u3059\u3002\u30ad\u30e3\u30d4\u30e9\u30ea\u30fc\u30b7\u30fc\u30b1\u30f3\u30b5\u30fc\u3092\u4f7f\u7528\u3059\u308b\u305f\u3081\u306b\u306f\u3001\u6bce\u65e5\u30fb\u6bce\u9031\u30fb\u6bce\u6708\u306e\u5b9a\u671f\u7684\u306a\u30e1\u30f3\u30c6\u30ca\u30f3\u30b9\u304c\u5fc5\u9808\u3067\u3059\u304c\u3001\u30e1\u30f3\u30c6\u30ca\u30f3\u30b9\u306e\u624b\u9593\u304c\u304b\u304b\u3089\u306a\u3044\u88c5\u7f6e\u3092\u671b\u3093\u3067\u3044\u308b\u65b9\u304c\u591a\u304f\u3044\u3089\u3063\u3057\u3083\u3044\u307e\u3059\u3002<\/p>\n<p>\u305d\u3053\u3067\u4eca\u56de\u306f\u3001\u30e1\u30f3\u30c6\u30ca\u30f3\u30b9\u304c\u307b\u3068\u3093\u3069\u3044\u3089\u306a\u3044\u3001\u65b0\u578b\u30ad\u30e3\u30d4\u30e9\u30ea\u30fc\u30b7\u30fc\u30b1\u30f3\u30b5\u30fcApplied Biosystems\u2122SeqStudio\u2122 Genetic Analyzer \u3092\u3054\u7d39\u4ecb\u3044\u305f\u3057\u307e\u3059\u3002<\/p>\n<p>\u25bc\u3053\u3093\u306a\u65b9\u306b\u304a\u3059\u3059\u3081\u3067\u3059\uff01<br \/>\n\u30fb\u30ad\u30e3\u30d4\u30e9\u30ea\u30fc\u30b7\u30fc\u30b1\u30f3\u30b5\u30fc\u306e\u8cfc\u5165\u3092\u3054\u691c\u8a0e\u3055\u308c\u3066\u3044\u308b\u65b9<br \/>\n\u30fb\u30e1\u30f3\u30c6\u30ca\u30f3\u30b9\u306e\u624b\u9593\u3092\u7701\u3044\u305f\u30b7\u30fc\u30b1\u30f3\u30b5\u30fc\u306b\u8208\u5473\u304c\u3042\u308b\u65b9<\/p>\n<h2>\u3053\u308c\u307e\u3067\u306e\u30ad\u30e3\u30d4\u30e9\u30ea\u30fc\u30b7\u30fc\u30b1\u30f3\u30b5\u30fc\u306e\u30e1\u30f3\u30c6\u30ca\u30f3\u30b9\u3068\u306f\uff1f<\/h2>\n<p>\u5f0a\u793e\u306e\u5f93\u6765\u306e\u30ad\u30e3\u30d4\u30e9\u30ea\u30fc\u30b7\u30fc\u30b1\u30f3\u30b5\u30fc\u306b\u5fc5\u8981\u306a\u88c5\u7f6e\u5074\u306e\u6d88\u8017\u54c1\u3068\u305d\u308c\u305e\u308c\u306e\u30e1\u30f3\u30c6\u30ca\u30f3\u30b9\u306f\u4ee5\u4e0b\u306e\u901a\u308a\u3067\u3059\u3002<br \/>\n\u2460\u30ad\u30e3\u30d4\u30e9\u30ea\u30fc\uff1a<br \/>\n\u4f7f\u7528\u72b6\u6cc1\u306b\u5fdc\u3058\u3001\u6570\u304b\u6708\u3054\u3068\u306b\u4ea4\u63db\u3057\u307e\u3059\u3002<br \/>\n\u4ea4\u63db\u5f8c\u306f\u300c\u30ad\u30e3\u30ea\u30d6\u30ec\u30fc\u30b7\u30e7\u30f3\u300d\u3068\u547c\u3070\u308c\u308b\u30e1\u30f3\u30c6\u30ca\u30f3\u30b9\u304c\u5fc5\u8981\u306b\u306a\u308a\u307e\u3059\u3002<\/p>\n<p>\u2461\u30dd\u30ea\u30de\u30fc\uff1a<br \/>\n1\u9031\u9593\u30842\u9031\u9593\u3054\u3068\u306b\u4ea4\u63db\u3057\u307e\u3059\u3002<br \/>\n\u5ba4\u6e29\u72b6\u614b\u3067\u306f\u5f90\u3005\u306b\u52a3\u5316\u304c\u9032\u307f\u3001DNA\u306e\u5206\u96e2\u304c\u4e0a\u624b\u304f\u884c\u3048\u306a\u304f\u306a\u308a\u307e\u3059\u3002<\/p>\n<p>\u2462\u967d\u6975\u30d0\u30c3\u30d5\u30a1\uff1a<br \/>\n10X\u6fc3\u5ea6\u306e\u30d0\u30c3\u30d5\u30a1\u30921X\u306b\u5e0c\u91c8\u3057\u3001\u6bce\u65e5\u4ea4\u63db\u3057\u307e\u3059\u3002<\/p>\n<p>\u2463\u9670\u6975\u30d0\u30c3\u30d5\u30a1\uff1a<br \/>\n10X\u6fc3\u5ea6\u306e\u30d0\u30c3\u30d5\u30a1\u30921X\u306b\u5e0c\u91c8\u3057\u3001\u6bce\u65e5\u4ea4\u63db\u3057\u307e\u3059\u3002<\/p>\n<p>\u3055\u3089\u306b\u3001\u30ad\u30e3\u30d4\u30e9\u30ea\u30fc\u306e\u4e2d\u306b\u30dd\u30ea\u30de\u30fc\u3092\u5145\u586b\u3059\u308b\u305f\u3081\u306e\u6a5f\u69cb\uff1a\u2464\u30dd\u30f3\u30d7\u30d6\u30ed\u30c3\u30af\u306e\u5b9a\u671f\u7684\u306a\u6d17\u6d44\u3082\u5fc5\u8981\u3067\u3059\u3002<br \/>\n\u3053\u306e\u3088\u3046\u306b\u5f93\u6765\u306e\u30ad\u30e3\u30d4\u30e9\u30ea\u30fc\u30b7\u30fc\u30b1\u30f3\u30b5\u30fc\u3067\u306f\u3001\u6d88\u8017\u54c1\u304c\u8907\u6570\u3042\u308a\u3001\u30e1\u30f3\u30c6\u30ca\u30f3\u30b9\u306b1\u6642\u9593\uff5e\u534a\u65e5\u7a0b\u5ea6\u304b\u304b\u3063\u3066\u3057\u307e\u3046\u3082\u306e\u3067\u3057\u305f\u3002<\/p>\n<h2>\u8907\u6570\u306e\u6d88\u8017\u54c1\u304c\u30aa\u30fc\u30eb\u30a4\u30f3\u30ef\u30f3\u3068\u306a\u3063\u305f\u9769\u65b0\u7684\u306a\u30ab\u30fc\u30c8\u30ea\u30c3\u30b8<\/h2>\n<div id=\"attachment_6307\" style=\"width: 310px\" class=\"wp-caption alignright\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-6307\" class=\"wp-image-6307 size-medium\" src=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2020\/04\/e633e1fe2684daa1b45ea51df0fd1835-300x277.jpg\" alt=\"\" width=\"300\" height=\"277\" srcset=\"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2020\/04\/e633e1fe2684daa1b45ea51df0fd1835-300x277.jpg 300w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2020\/04\/e633e1fe2684daa1b45ea51df0fd1835.jpg 650w\" sizes=\"auto, (max-width: 300px) 100vw, 300px\" \/><p id=\"caption-attachment-6307\" class=\"wp-caption-text\">\u56f32\uff1a\u30ab\u30fc\u30c8\u30ea\u30c3\u30b8<\/p><\/div>\n<p>SeqStudio\u3067\u306f\u4e0a\u8a18\u306e\u3046\u3061\u306e4\u70b9\uff08\u2460\u30ad\u30e3\u30d4\u30e9\u30ea\u30fc\u3001\u2461\u30dd\u30ea\u30de\u30fc\u3001\u2462\u967d\u6975\u30d0\u30c3\u30d5\u30a1\u3001\u2464\u30dd\u30f3\u30d7\u30d6\u30ed\u30c3\u30af\uff09\u3092\u7d44\u307f\u8fbc\u3093\u3060\u30aa\u30fc\u30eb\u30a4\u30f3\u30ef\u30f3\u306e\u300c\u30ab\u30fc\u30c8\u30ea\u30c3\u30b8\u300d\u3092\u4f7f\u7528\u3057\u307e\u3059\u3002<\/p>\n<p>\u88c5\u7f6e\u304b\u3089\u53e4\u3044\u3082\u306e\u3092\u53d6\u308a\u51fa\u3057\u3001\u51b7\u8535\u5eab\u304b\u3089\u53d6\u308a\u51fa\u3057\u305f\u65b0\u3057\u3044\u30ab\u30fc\u30c8\u30ea\u30c3\u30b8\u3092\u88c5\u7f6e\u306b\u5dee\u3057\u8fbc\u3080\u3060\u3051\u306e\u308f\u305a\u304b2\u5206\u3067\u6d88\u8017\u54c1\u306e\u4ea4\u63db\u3068\u30e1\u30f3\u30c6\u30ca\u30f3\u30b9\u3092\u5b8c\u4e86\u3067\u304d\u307e\u3059\u3002<\/p>\n<p>\u30ab\u30fc\u30c8\u30ea\u30c3\u30b8\u306f\u88c5\u7f6e\u306b\u30bb\u30c3\u30c8\u3057\u305f\u72b6\u614b\u3067\u3001\u6700\u95774\u304b\u6708\u9593\uff08\uff0a\uff09\u305d\u306e\u307e\u307e\u4f7f\u7528\u3059\u308b\u3053\u3068\u304c\u53ef\u80fd\u3067\u3059\u306e\u3067\u3001\u6d88\u8017\u54c1\u3054\u3068\u306e\u4f7f\u7528\u671f\u9650\u3092\u6c17\u306b\u3059\u308b\u5fc5\u8981\u306f\u3042\u308a\u307e\u305b\u3093\u3002<br \/>\n<span style=\"color: blue\">\uff0a\u88fd\u54c1\u756a\u53f7A33671\uff08125\u30a4\u30f3\u30b8\u30a7\u30af\u30b7\u30e7\u30f3\uff09\u306f4\u304b\u6708\u3001\u88fd\u54c1\u756a\u53f7A41331\uff08250\u30a4\u30f3\u30b8\u30a7\u30af\u30b7\u30e7\u30f3\uff09\u306f6\u304b\u6708\u4f7f\u7528\u53ef\u80fd<\/span><\/p>\n<div id=\"attachment_6308\" style=\"width: 310px\" class=\"wp-caption alignright\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-6308\" class=\"wp-image-6308 size-medium\" src=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2020\/04\/50b9a42ab37717b1da8afa9841f42686-300x275.png\" alt=\"\" width=\"300\" height=\"275\" srcset=\"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2020\/04\/50b9a42ab37717b1da8afa9841f42686-300x275.png 300w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2020\/04\/50b9a42ab37717b1da8afa9841f42686.png 318w\" sizes=\"auto, (max-width: 300px) 100vw, 300px\" \/><p id=\"caption-attachment-6308\" class=\"wp-caption-text\">\u56f33\uff1a\u30e1\u30f3\u30c6\u30ca\u30f3\u30b9\u64cd\u4f5c<\/p><\/div>\n<p>\u3055\u3089\u306b\u3001\u30ab\u30fc\u30c8\u30ea\u30c3\u30b8\u5185\u306e\u5404\u90e8\u54c1\u305d\u308c\u305e\u308c\u306b\u4e0b\u8a18\u306e\u3088\u3046\u306a\u8981\u7d20\u304c\u8a70\u3081\u8fbc\u307e\u308c\u3066\u304a\u308a\u3001\u30e1\u30f3\u30c6\u30ca\u30f3\u30b9\u3092\u683c\u6bb5\u306b\u7c21\u6613\u306b\u3057\u307e\u3059<br \/>\n\u2460\u30ad\u30e3\u30d4\u30e9\u30ea\u30fc\uff1a\u8a2d\u7f6e\u5f8c\u306e\u300c\u30ad\u30e3\u30ea\u30d6\u30ec\u30fc\u30b7\u30e7\u30f3\u300d\u306e\u5b9f\u65bd\u304c\u4e0d\u8981<br \/>\n\u2461\u30dd\u30ea\u30de\u30fc\uff1a\u88c5\u7f6e\u306b\u53d6\u308a\u4ed8\u3051\u305f\u307e\u307e\uff14\u304b\u6708\u9593\u4f7f\u7528\u53ef\u80fd<br \/>\n\u2462\u967d\u6975\u30d0\u30c3\u30d5\u30a1\uff1a\u5e0c\u91c8\u8abf\u88fd\u304c\u4e0d\u8981<br \/>\n\u2464\u30dd\u30f3\u30d7\u30d6\u30ed\u30c3\u30af\uff1a\u5b9a\u671f\u7684\u306a\u6d17\u6d44\u304c\u4e0d\u8981<\/p>\n<h3><\/h3>\n<p>\u307e\u305f\u3001\u30ab\u30fc\u30c8\u30ea\u30c3\u30b8\u3068\u306f\u5225\u306b\u2463\u9670\u6975\u30d0\u30c3\u30d5\u30a1\u3092\u88c5\u7f6e\u306b\u30bb\u30c3\u30c8\u3059\u308b\u5fc5\u8981\u304c\u3042\u308a\u307e\u3059\u3002<br \/>\n\u3057\u304b\u3057\u3001\u8a66\u85ac\u8abf\u88fd\u6e08\u307f\u306e\u30d0\u30c3\u30d5\u30a1\u304c\u5206\u6ce8\u3055\u308c\u3066\u3044\u308b\u30b3\u30f3\u30c6\u30ca\u3092\u30bb\u30c3\u30c8\u3059\u308b\u3060\u3051\u3067\u3059\u306e\u3067\u3001\u3053\u3061\u3089\u30822\u5206\u7a0b\u5ea6\u3067\u30e1\u30f3\u30c6\u30ca\u30f3\u30b9\u3092\u7d42\u3048\u308b\u3053\u3068\u304c\u3067\u304d\u307e\u3059\u3002<\/p>\n<div id=\"attachment_6309\" style=\"width: 310px\" class=\"wp-caption alignright\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-6309\" class=\"size-medium wp-image-6309\" src=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2020\/04\/7209b009339725c3302735db2ddcf2b3-300x277.jpg\" alt=\"\" width=\"300\" height=\"277\" srcset=\"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2020\/04\/7209b009339725c3302735db2ddcf2b3-300x277.jpg 300w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2020\/04\/7209b009339725c3302735db2ddcf2b3.jpg 650w\" sizes=\"auto, (max-width: 300px) 100vw, 300px\" \/><p id=\"caption-attachment-6309\" class=\"wp-caption-text\">\u56f34\uff1a\u9670\u6975\u30d0\u30c3\u30d5\u30a1\u30b3\u30f3\u30c6\u30ca<\/p><\/div>\n<p>\u9670\u6975\u30d0\u30c3\u30d5\u30a1\u306f\u88c5\u7f6e\u306b\u30bb\u30c3\u30c8\u5f8c\u30012\u9031\u9593\u305d\u306e\u307e\u307e\u4f7f\u7528\u3059\u308b\u3053\u3068\u304c\u53ef\u80fd\u3067\u3059\u306e\u3067\u3001\u4ea4\u63db\u983b\u5ea6\u304c\u4f4e\u304f\u306a\u308a\u3001\u975e\u5e38\u306b\u7c21\u5358\u306b\u306a\u3063\u3066\u3044\u307e\u3059\u3002<\/p>\n<p>SeqStudio\u306e\u30e1\u30f3\u30c6\u30f3\u30ca\u30f3\u30b9\u306f\u4e0a\u8a182\u3064\u306e\u6d88\u8017\u54c1\uff08\u30ab\u30fc\u30c8\u30ea\u30c3\u30b8\u3068\u9670\u6975\u30d0\u30c3\u30d5\u30a1\uff09\u3092\u4ea4\u63db\u3059\u308b\u3060\u3051\u3067\u3059\u3002<br \/>\n\u88c5\u7f6e\u306b\u3000\u5dee\u3057\u8fbc\u3080\u3060\u3051\uff0f\u8a2d\u7f6e\u3059\u308b\u3060\u3051\u3000\u3067\u4ea4\u63db\u3067\u304d\u307e\u3059\u306e\u3067\u3001\u305d\u308c\u305e\u308c2\u5206\u7a0b\u5ea6\u3057\u304b\u6642\u9593\u304c\u304b\u304b\u3089\u306a\u3044\u306e\u304c\u3001\u30e1\u30f3\u30c6\u30ca\u30f3\u30b9\u304c\u7c21\u5358\u306b\u306a\u3063\u305f\u30dd\u30a4\u30f3\u30c8\u3067\u3059\u3002<\/p>\n<h2><\/h2>\n<h2><\/h2>\n<h2><\/h2>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<h2>\u30e1\u30f3\u30c6\u30ca\u30f3\u30b9\u4ee5\u5916\u306b\u3082\u304a\u624b\u8efd\u8981\u7d20\u304c\u305f\u304f\u3055\u3093\uff01<\/h2>\n<p>SeqStudio\u306f\u30e1\u30f3\u30c6\u30ca\u30f3\u30b9\u4ee5\u5916\u306b\u3082\u4f7f\u3044\u6613\u304f\u306a\u3063\u3066\u3044\u308b\u30dd\u30a4\u30f3\u30c8\u304c\u3042\u308a\u307e\u3059\u3002<\/p>\n<p><strong>\u30fb\u30e9\u30f3\u306e\u30bb\u30c3\u30c8\u30a2\u30c3\u30d7\u304c\u7c21\u5358<\/strong><br \/>\n\u88c5\u7f6e\u672c\u4f53\u306e\u30e2\u30cb\u30bf\u304c\u30bf\u30c3\u30c1\u30d1\u30cd\u30eb\u306e\u305f\u3081\u3001\u30b9\u30de\u30fc\u30c8\u30d5\u30a9\u30f3\u3092\u64cd\u4f5c\u3059\u308b\u611f\u899a\u3067\u3001\u7c21\u5358\u306b\u30e9\u30f3\u306e\u30bb\u30c3\u30c8\u30a2\u30c3\u30d7\u3092\u884c\u3048\u307e\u3059\u3002<\/p>\n<div id=\"attachment_6310\" style=\"width: 310px\" class=\"wp-caption aligncenter\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-6310\" class=\"size-medium wp-image-6310\" src=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2020\/04\/dd77627697a3a916c8c149218bade90d-300x185.png\" alt=\"\" width=\"300\" height=\"185\" srcset=\"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2020\/04\/dd77627697a3a916c8c149218bade90d-300x185.png 300w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2020\/04\/dd77627697a3a916c8c149218bade90d.png 424w\" sizes=\"auto, (max-width: 300px) 100vw, 300px\" \/><p id=\"caption-attachment-6310\" class=\"wp-caption-text\">\u56f35\uff1a\u30bb\u30c3\u30c8\u30a2\u30c3\u30d7\u753b\u9762<\/p><\/div>\n<p><strong>\u30fb\u65b0\u305f\u306a\u63a5\u7d9a\u6027\u306e\u7372\u5f97<\/strong><br \/>\n\u30ef\u30a4\u30e4\u30ec\u30b9\u63a5\u7d9a\u3092\u5c0e\u5165\u3057\u305f\u305f\u3081\u3001\u30af\u30e9\u30a6\u30c9\uff08Thermo Fisher Connect\uff09\u3092\u5229\u7528\u3059\u308b\u3053\u3068\u3067\u3001\u30e9\u30f3\u306e\u30e2\u30cb\u30bf\u30ea\u30f3\u30b0\u3084\u30e9\u30f3\u30c7\u30fc\u30bf\u306e\u78ba\u8a8d\u306a\u3069\u3092\u9060\u9694\u3067\u884c\u3046\u3053\u3068\u304c\u3067\u304d\u307e\u3059\u3002<\/p>\n<div id=\"attachment_6311\" style=\"width: 310px\" class=\"wp-caption aligncenter\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-6311\" class=\"size-medium wp-image-6311\" src=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2020\/04\/db372ec0805eabfadd9849146e476835-300x159.png\" alt=\"\" width=\"300\" height=\"159\" srcset=\"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2020\/04\/db372ec0805eabfadd9849146e476835-300x159.png 300w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2020\/04\/db372ec0805eabfadd9849146e476835.png 441w\" sizes=\"auto, (max-width: 300px) 100vw, 300px\" \/><p id=\"caption-attachment-6311\" class=\"wp-caption-text\">\u56f36\uff1a\u65b0\u305f\u306a\u63a5\u7d9a\u6027<\/p><\/div>\n<p>\u307e\u305f\u3001\u5f93\u6765\u6a5f\u3068\u540c\u69d8\u306b\u3001DNA\u30b7\u30fc\u30b1\u30f3\u30b7\u30f3\u30b0\u3060\u3051\u3067\u306a\u304f\u3001\u30d5\u30e9\u30b0\u30e1\u30f3\u30c8\u89e3\u6790\u3082\u884c\u3048\u307e\u3059\u306e\u3067\u3001\u3055\u307e\u3056\u307e\u306a\u30a2\u30d7\u30ea\u30b1\u30fc\u30b7\u30e7\u30f3\u306b\u5bfe\u5fdc\u3057\u305f\u30b7\u30b9\u30c6\u30e0\u3068\u8a00\u3048\u307e\u3059\u3002<\/p>\n<h2>\u307e\u3068\u3081<\/h2>\n<p>\u30fbSeqStudio\u306f\u6d88\u8017\u54c1\u304c\u30aa\u30fc\u30eb\u30a4\u30f3\u30ef\u30f3\u306e\u30ab\u30fc\u30c8\u30ea\u30c3\u30b8\u3068\u9670\u6975\u30d0\u30c3\u30d5\u30a1\u306e2\u3064\u306e\u307f\uff01<br \/>\n\u30fbSeqStudio\u306e\u30e1\u30f3\u30c6\u30ca\u30f3\u30b9\u306f\u53e4\u304f\u306a\u3063\u305f\u6d88\u8017\u54c1\u3092\u4e57\u305b\u63db\u3048\u308b\u3060\u3051\u3067\u7c21\u5358\u3001\u6642\u77ed\uff01<br \/>\n\u30fbSeqStudio\u306f\u304a\u624b\u8efd\u8981\u7d20\u304c\u8c4a\u5bcc\uff01<br \/>\nSeqStudio\u306b\u3054\u8208\u5473\u3092\u304a\u6301\u3061\u9802\u3051\u307e\u3057\u305f\u3089\u3001\u4e0b\u8a18\u52d5\u753b\u3067\u3055\u3089\u306b\u30a4\u30e1\u30fc\u30b8\u3092\u81a8\u3089\u307e\u305b\u3066\u3044\u305f\u3060\u3051\u307e\u3059\u3002<br \/>\n<iframe loading=\"lazy\" title=\"Introducing the Applied Biosystems SeqStudio Genetic Analyzer\" width=\"760\" height=\"428\" src=\"https:\/\/www.youtube.com\/embed\/htoWfeQvysc?list=PLGlvFEwL2wDHM7wsRhF5bS9zm6Nd_f61W\" frameborder=\"0\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share\" referrerpolicy=\"strict-origin-when-cross-origin\" allowfullscreen><\/iframe><\/p>\n<h2>\uff3b\u7121\u6599\u516c\u958b\u4e2d\uff3d\u30b5\u30f3\u30ac\u30fc\u30b7\u30fc\u30b1\u30f3\u30b9\u306e\u57fa\u790e<\/h2>\n<p>\u30b7\u30fc\u30b1\u30f3\u30b9\u306e\u30ef\u30fc\u30af\u30d5\u30ed\u30fc\u3084\u30c7\u30fc\u30bf\u304b\u3089\u306e\u30c8\u30e9\u30d6\u30eb\u30b7\u30e5\u30fc\u30c8\u306b\u3064\u3044\u3066\u306f\u3001\u3053\u3061\u3089\u306e\u30ac\u30a4\u30c9\u306b\u3082\u8a73\u3057\u3044\u8a18\u8f09\u304c\u3054\u3056\u3044\u307e\u3059\u3002\u305c\u3072\u3054\u6d3b\u7528\u304f\u3060\u3055\u3044\u3002<\/p>\n<p><a class=\"btn btn-red\" href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/global\/forms\/sanger-sequencing-guide-download.html?CID=gsd_cap_sbu_r04_jp_cp1349_pjt5618_gsd00000_0so_blg_op_lgn_kt_s00_dne3_Social_LAB\" target=\"_blank\" rel=\"noopener noreferrer\">\u30c0\u30a6\u30f3\u30ed\u30fc\u30c9\u3059\u308b<\/a><\/p>\n<p>&nbsp;<\/p>\n<p>\u7814\u7a76\u7528\u306b\u306e\u307f\u4f7f\u7528\u3067\u304d\u307e\u3059\u3002\u8a3a\u65ad\u7528\u306b\u306f\u4f7f\u7528\u3044\u305f\u3060\u3051\u307e\u305b\u3093\u3002<\/p>\n","protected":false},"excerpt":{"rendered":"<p>\u907a\u4f1d\u5b50\u89e3\u6790\u306e\u57fa\u672c\u624b\u6bb5\u306e\u4e00\u3064\u306f\u3001DNA\u306e\u5869\u57fa\u914d\u5217\u3092\u6c7a\u5b9a\u3059\u308b\u3053\u3068\uff08DNA\u30b7\u30fc\u30b1\u30f3\u30b7\u30f3\u30b0\uff09\u3067\u3059\u3002\u73fe\u5728\u306f\u30ad\u30e3\u30d4\u30e9\u30ea\u30fc\u96fb\u6c17\u6cf3\u52d5\u30b7\u30b9\u30c6\u30e0\u3092\u7528\u3044\u305f\u30b7\u30fc\u30b1\u30f3\u30b5\u30fc\u3067\u306e\u89e3\u6790\u304c\u4e3b\u6d41\u3067\u3059\u3002\u30ad\u30e3\u30d4\u30e9\u30ea\u30fc\u30b7\u30fc\u30b1\u30f3\u30b5\u30fc\u3092\u4f7f\u7528\u3059\u308b\u305f\u3081\u306b\u306f\u3001\u6bce\u65e5\u30fb\u6bce\u9031\u30fb<\/p>\n","protected":false},"author":975,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_monsterinsights_skip_tracking":false,"_genesis_hide_title":false,"_genesis_hide_breadcrumbs":false,"_genesis_hide_singular_image":false,"_genesis_hide_footer_widgets":false,"_genesis_custom_body_class":"","_genesis_custom_post_class":"","_genesis_layout":"","_jetpack_newsletter_access":"","_jetpack_dont_email_post_to_subs":false,"_jetpack_newsletter_tier_id":0,"_jetpack_memberships_contains_paywalled_content":false,"_jetpack_feature_clip_id":0,"_jetpack_memberships_contains_paid_content":false,"footnotes":"","jetpack_post_was_ever_published":false},"categories":[156],"tags":[172],"division":[],"class_list":{"0":"post-6305","1":"post","2":"type-post","3":"status-publish","4":"format-standard","6":"category-mol-bio","7":"tag-ce","8":"entry"},"_selected_authors":"","_selected_reviewers":"","acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v27.8 (Yoast SEO v27.8) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>\u30e1\u30f3\u30c6\u30ca\u30f3\u30b9\u304c\u307b\u3068\u3093\u3069\u3044\u3089\u306a\u3044\u30b7\u30fc\u30b1\u30f3\u30b5\u30fc\uff01\uff1fSeqStudio\u3063\u3066\u3069\u3093\u306a\u88c5\u7f6e\uff1f - Learning at the Bench<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/seqstudio_ce_gsd_ts_1\/\" \/>\n<meta property=\"og:locale\" content=\"ja_JP\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"\u30e1\u30f3\u30c6\u30ca\u30f3\u30b9\u304c\u307b\u3068\u3093\u3069\u3044\u3089\u306a\u3044\u30b7\u30fc\u30b1\u30f3\u30b5\u30fc\uff01\uff1fSeqStudio\u3063\u3066\u3069\u3093\u306a\u88c5\u7f6e\uff1f\" \/>\n<meta property=\"og:description\" content=\"\u907a\u4f1d\u5b50\u89e3\u6790\u306e\u57fa\u672c\u624b\u6bb5\u306e\u4e00\u3064\u306f\u3001DNA\u306e\u5869\u57fa\u914d\u5217\u3092\u6c7a\u5b9a\u3059\u308b\u3053\u3068\uff08DNA\u30b7\u30fc\u30b1\u30f3\u30b7\u30f3\u30b0\uff09\u3067\u3059\u3002\u73fe\u5728\u306f\u30ad\u30e3\u30d4\u30e9\u30ea\u30fc\u96fb\u6c17\u6cf3\u52d5\u30b7\u30b9\u30c6\u30e0\u3092\u7528\u3044\u305f\u30b7\u30fc\u30b1\u30f3\u30b5\u30fc\u3067\u306e\u89e3\u6790\u304c\u4e3b\u6d41\u3067\u3059\u3002\u30ad\u30e3\u30d4\u30e9\u30ea\u30fc\u30b7\u30fc\u30b1\u30f3\u30b5\u30fc\u3092\u4f7f\u7528\u3059\u308b\u305f\u3081\u306b\u306f\u3001\u6bce\u65e5\u30fb\u6bce\u9031\u30fb\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/seqstudio_ce_gsd_ts_1\/\" \/>\n<meta property=\"og:site_name\" content=\"Learning at the Bench\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/ThermoFisherJapan\" \/>\n<meta property=\"article:published_time\" content=\"2020-05-27T00:21:36+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2024-09-18T08:20:53+00:00\" \/>\n<meta property=\"og:image\" content=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2020\/04\/cb61dab8d2d388a32a533c85bc1c8200-300x277.jpg\" \/>\n<meta name=\"author\" content=\"LatB Staff\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:creator\" content=\"@ThermoFisherJP\" \/>\n<meta name=\"twitter:site\" content=\"@ThermoFisherJP\" \/>\n<meta name=\"twitter:label1\" content=\"\u57f7\u7b46\u8005\" \/>\n\t<meta name=\"twitter:data1\" content=\"LatB Staff\" \/>\n\t<meta name=\"twitter:label2\" content=\"\u63a8\u5b9a\u8aad\u307f\u53d6\u308a\u6642\u9593\" \/>\n\t<meta name=\"twitter:data2\" content=\"8\u5206\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/seqstudio_ce_gsd_ts_1\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/seqstudio_ce_gsd_ts_1\\\/\"},\"author\":{\"name\":\"LatB Staff\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#\\\/schema\\\/person\\\/bdbe319a2001f279ddce6ab8eaad1253\"},\"headline\":\"\u30e1\u30f3\u30c6\u30ca\u30f3\u30b9\u304c\u307b\u3068\u3093\u3069\u3044\u3089\u306a\u3044\u30b7\u30fc\u30b1\u30f3\u30b5\u30fc\uff01\uff1fSeqStudio\u3063\u3066\u3069\u3093\u306a\u88c5\u7f6e\uff1f\",\"datePublished\":\"2020-05-27T00:21:36+00:00\",\"dateModified\":\"2024-09-18T08:20:53+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/seqstudio_ce_gsd_ts_1\\\/\"},\"wordCount\":93,\"commentCount\":0,\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/seqstudio_ce_gsd_ts_1\\\/#primaryimage\"},\"thumbnailUrl\":\"http:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2020\\\/04\\\/cb61dab8d2d388a32a533c85bc1c8200-300x277.jpg\",\"keywords\":[\"\u30ad\u30e3\u30d4\u30e9\u30ea\u30fc\u96fb\u6c17\u6cf3\u52d5\"],\"articleSection\":[\"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023\"],\"inLanguage\":\"ja\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/seqstudio_ce_gsd_ts_1\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/seqstudio_ce_gsd_ts_1\\\/\",\"url\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/seqstudio_ce_gsd_ts_1\\\/\",\"name\":\"\u30e1\u30f3\u30c6\u30ca\u30f3\u30b9\u304c\u307b\u3068\u3093\u3069\u3044\u3089\u306a\u3044\u30b7\u30fc\u30b1\u30f3\u30b5\u30fc\uff01\uff1fSeqStudio\u3063\u3066\u3069\u3093\u306a\u88c5\u7f6e\uff1f - Learning at the Bench\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/seqstudio_ce_gsd_ts_1\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/seqstudio_ce_gsd_ts_1\\\/#primaryimage\"},\"thumbnailUrl\":\"http:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2020\\\/04\\\/cb61dab8d2d388a32a533c85bc1c8200-300x277.jpg\",\"datePublished\":\"2020-05-27T00:21:36+00:00\",\"dateModified\":\"2024-09-18T08:20:53+00:00\",\"author\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#\\\/schema\\\/person\\\/bdbe319a2001f279ddce6ab8eaad1253\"},\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/seqstudio_ce_gsd_ts_1\\\/#breadcrumb\"},\"inLanguage\":\"ja\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/seqstudio_ce_gsd_ts_1\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"ja\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/seqstudio_ce_gsd_ts_1\\\/#primaryimage\",\"url\":\"http:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2020\\\/04\\\/cb61dab8d2d388a32a533c85bc1c8200-300x277.jpg\",\"contentUrl\":\"http:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2020\\\/04\\\/cb61dab8d2d388a32a533c85bc1c8200-300x277.jpg\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/seqstudio_ce_gsd_ts_1\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"\u30e1\u30f3\u30c6\u30ca\u30f3\u30b9\u304c\u307b\u3068\u3093\u3069\u3044\u3089\u306a\u3044\u30b7\u30fc\u30b1\u30f3\u30b5\u30fc\uff01\uff1fSeqStudio\u3063\u3066\u3069\u3093\u306a\u88c5\u7f6e\uff1f\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#website\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/\",\"name\":\"Learning at the Bench\",\"description\":\"\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"ja\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#\\\/schema\\\/person\\\/bdbe319a2001f279ddce6ab8eaad1253\",\"name\":\"LatB Staff\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"ja\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g\",\"caption\":\"LatB Staff\"},\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/author\\\/lgbadmin\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"\u30e1\u30f3\u30c6\u30ca\u30f3\u30b9\u304c\u307b\u3068\u3093\u3069\u3044\u3089\u306a\u3044\u30b7\u30fc\u30b1\u30f3\u30b5\u30fc\uff01\uff1fSeqStudio\u3063\u3066\u3069\u3093\u306a\u88c5\u7f6e\uff1f - Learning at the Bench","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/seqstudio_ce_gsd_ts_1\/","og_locale":"ja_JP","og_type":"article","og_title":"\u30e1\u30f3\u30c6\u30ca\u30f3\u30b9\u304c\u307b\u3068\u3093\u3069\u3044\u3089\u306a\u3044\u30b7\u30fc\u30b1\u30f3\u30b5\u30fc\uff01\uff1fSeqStudio\u3063\u3066\u3069\u3093\u306a\u88c5\u7f6e\uff1f","og_description":"\u907a\u4f1d\u5b50\u89e3\u6790\u306e\u57fa\u672c\u624b\u6bb5\u306e\u4e00\u3064\u306f\u3001DNA\u306e\u5869\u57fa\u914d\u5217\u3092\u6c7a\u5b9a\u3059\u308b\u3053\u3068\uff08DNA\u30b7\u30fc\u30b1\u30f3\u30b7\u30f3\u30b0\uff09\u3067\u3059\u3002\u73fe\u5728\u306f\u30ad\u30e3\u30d4\u30e9\u30ea\u30fc\u96fb\u6c17\u6cf3\u52d5\u30b7\u30b9\u30c6\u30e0\u3092\u7528\u3044\u305f\u30b7\u30fc\u30b1\u30f3\u30b5\u30fc\u3067\u306e\u89e3\u6790\u304c\u4e3b\u6d41\u3067\u3059\u3002\u30ad\u30e3\u30d4\u30e9\u30ea\u30fc\u30b7\u30fc\u30b1\u30f3\u30b5\u30fc\u3092\u4f7f\u7528\u3059\u308b\u305f\u3081\u306b\u306f\u3001\u6bce\u65e5\u30fb\u6bce\u9031\u30fb","og_url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/seqstudio_ce_gsd_ts_1\/","og_site_name":"Learning at the Bench","article_publisher":"https:\/\/www.facebook.com\/ThermoFisherJapan","article_published_time":"2020-05-27T00:21:36+00:00","article_modified_time":"2024-09-18T08:20:53+00:00","og_image":[{"url":"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2020\/04\/cb61dab8d2d388a32a533c85bc1c8200-300x277.jpg","type":"","width":"","height":""}],"author":"LatB Staff","twitter_card":"summary_large_image","twitter_creator":"@ThermoFisherJP","twitter_site":"@ThermoFisherJP","twitter_misc":{"\u57f7\u7b46\u8005":"LatB Staff","\u63a8\u5b9a\u8aad\u307f\u53d6\u308a\u6642\u9593":"8\u5206"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/seqstudio_ce_gsd_ts_1\/#article","isPartOf":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/seqstudio_ce_gsd_ts_1\/"},"author":{"name":"LatB Staff","@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#\/schema\/person\/bdbe319a2001f279ddce6ab8eaad1253"},"headline":"\u30e1\u30f3\u30c6\u30ca\u30f3\u30b9\u304c\u307b\u3068\u3093\u3069\u3044\u3089\u306a\u3044\u30b7\u30fc\u30b1\u30f3\u30b5\u30fc\uff01\uff1fSeqStudio\u3063\u3066\u3069\u3093\u306a\u88c5\u7f6e\uff1f","datePublished":"2020-05-27T00:21:36+00:00","dateModified":"2024-09-18T08:20:53+00:00","mainEntityOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/seqstudio_ce_gsd_ts_1\/"},"wordCount":93,"commentCount":0,"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/seqstudio_ce_gsd_ts_1\/#primaryimage"},"thumbnailUrl":"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2020\/04\/cb61dab8d2d388a32a533c85bc1c8200-300x277.jpg","keywords":["\u30ad\u30e3\u30d4\u30e9\u30ea\u30fc\u96fb\u6c17\u6cf3\u52d5"],"articleSection":["\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023"],"inLanguage":"ja","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/seqstudio_ce_gsd_ts_1\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/seqstudio_ce_gsd_ts_1\/","url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/seqstudio_ce_gsd_ts_1\/","name":"\u30e1\u30f3\u30c6\u30ca\u30f3\u30b9\u304c\u307b\u3068\u3093\u3069\u3044\u3089\u306a\u3044\u30b7\u30fc\u30b1\u30f3\u30b5\u30fc\uff01\uff1fSeqStudio\u3063\u3066\u3069\u3093\u306a\u88c5\u7f6e\uff1f - Learning at the Bench","isPartOf":{"@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/seqstudio_ce_gsd_ts_1\/#primaryimage"},"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/seqstudio_ce_gsd_ts_1\/#primaryimage"},"thumbnailUrl":"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2020\/04\/cb61dab8d2d388a32a533c85bc1c8200-300x277.jpg","datePublished":"2020-05-27T00:21:36+00:00","dateModified":"2024-09-18T08:20:53+00:00","author":{"@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#\/schema\/person\/bdbe319a2001f279ddce6ab8eaad1253"},"breadcrumb":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/seqstudio_ce_gsd_ts_1\/#breadcrumb"},"inLanguage":"ja","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/seqstudio_ce_gsd_ts_1\/"]}]},{"@type":"ImageObject","inLanguage":"ja","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/seqstudio_ce_gsd_ts_1\/#primaryimage","url":"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2020\/04\/cb61dab8d2d388a32a533c85bc1c8200-300x277.jpg","contentUrl":"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2020\/04\/cb61dab8d2d388a32a533c85bc1c8200-300x277.jpg"},{"@type":"BreadcrumbList","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/seqstudio_ce_gsd_ts_1\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/"},{"@type":"ListItem","position":2,"name":"\u30e1\u30f3\u30c6\u30ca\u30f3\u30b9\u304c\u307b\u3068\u3093\u3069\u3044\u3089\u306a\u3044\u30b7\u30fc\u30b1\u30f3\u30b5\u30fc\uff01\uff1fSeqStudio\u3063\u3066\u3069\u3093\u306a\u88c5\u7f6e\uff1f"}]},{"@type":"WebSite","@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#website","url":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/","name":"Learning at the Bench","description":"","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"ja"},{"@type":"Person","@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#\/schema\/person\/bdbe319a2001f279ddce6ab8eaad1253","name":"LatB Staff","image":{"@type":"ImageObject","inLanguage":"ja","@id":"https:\/\/secure.gravatar.com\/avatar\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g","caption":"LatB Staff"},"url":"https:\/\/admin.acceleratingscience.com\/author\/lgbadmin\/"}]}},"taxonomy_info":{"category":[{"value":156,"label":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023"}],"post_tag":[{"value":172,"label":"\u30ad\u30e3\u30d4\u30e9\u30ea\u30fc\u96fb\u6c17\u6cf3\u52d5"}]},"featured_image_src_large":false,"author_info":{"display_name":"LatB Staff","author_link":"https:\/\/admin.acceleratingscience.com\/author\/lgbadmin\/"},"comment_info":0,"category_info":[{"term_id":156,"name":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","slug":"mol-bio","term_group":0,"term_taxonomy_id":156,"taxonomy":"category","description":"","parent":0,"count":538,"filter":"raw","meta":[],"cat_ID":156,"category_count":538,"category_description":"","cat_name":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","category_nicename":"mol-bio","category_parent":0}],"tag_info":[{"term_id":172,"name":"\u30ad\u30e3\u30d4\u30e9\u30ea\u30fc\u96fb\u6c17\u6cf3\u52d5","slug":"ce","term_group":0,"term_taxonomy_id":172,"taxonomy":"post_tag","description":"","parent":0,"count":34,"filter":"raw","meta":[]}],"jetpack-related-posts":[{"id":24647,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/sanger-seq-mutational-analysis-gsd-ts-ce-26007\/","url_meta":{"origin":6305,"position":0},"title":"\u30de\u30a4\u30ca\u30fc\u5909\u7570\u3092\u691c\u51fa\uff01Minor Variant Finder\u30bd\u30d5\u30c8\u30a6\u30a8\u30a2","author":"LatB Staff","date":"2026\u5e742\u67089\u65e5","format":false,"excerpt":"\u30ad\u30e3\u30d4\u30e9\u30ea\u30fc\u30b7\u30fc\u30b1\u30f3\u30b5\u3067\u306f\u300125%\u7a0b\u5ea6\u306e\u5272\u5408\u306e\u5909\u7570\u3092\u691c\u51fa\u3059\u308b\u3053\u3068\u304c\u3067\u304d\u307e\u3059\u304c\u3001\u3053\u308c\u3088\u308a\u3082\u4f4e\u3044\u5272\u5408\u306e\u5909\u2026","rel":"","context":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","block_context":{"text":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/mol-bio\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/01\/sanger-seq-mutational-analysis-gsd-ts-ce-26007_eyecatch.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/01\/sanger-seq-mutational-analysis-gsd-ts-ce-26007_eyecatch.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/01\/sanger-seq-mutational-analysis-gsd-ts-ce-26007_eyecatch.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/01\/sanger-seq-mutational-analysis-gsd-ts-ce-26007_eyecatch.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/01\/sanger-seq-mutational-analysis-gsd-ts-ce-26007_eyecatch.jpg?resize=1050%2C600&ssl=1 3x"},"classes":[]},{"id":24552,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/qubit-dna-bid-ts-mbr-26001\/","url_meta":{"origin":6305,"position":1},"title":"Qubit Fluorometer\u306b\u3064\u3044\u3066 \uff5eQubit Assay Kit\u306e\u6e2c\u5b9a\u7bc4\u56f2\uff5e","author":"LatB Staff","date":"2026\u5e741\u67089\u65e5","format":false,"excerpt":"Invitrogen\u2122 Qubit\u2122 Fluorometer \u306f\u3001\u5c02\u7528\u306e\u8a66\u85ac\u30ad\u30c3\u30c8\u3092\u7528\u3044\u308b\u3053\u3068\u3067DN\u2026","rel":"","context":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","block_context":{"text":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/mol-bio\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/12\/qubit-dna-bid-ts-mbr-26001_eyecatch.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/12\/qubit-dna-bid-ts-mbr-26001_eyecatch.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/12\/qubit-dna-bid-ts-mbr-26001_eyecatch.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/12\/qubit-dna-bid-ts-mbr-26001_eyecatch.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/12\/qubit-dna-bid-ts-mbr-26001_eyecatch.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/12\/qubit-dna-bid-ts-mbr-26001_eyecatch.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":24614,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/battery-manufacturing-elemental-analysis-csm-26005\/","url_meta":{"origin":6305,"position":2},"title":"\u96fb\u6c60\u30ea\u30b5\u30a4\u30af\u30eb\u306b\u304a\u3051\u308b\u5143\u7d20\u5206\u6790","author":"LatB Staff","date":"2026\u5e741\u670827\u65e5","format":false,"excerpt":"\u81ea\u52d5\u8eca\u306e\u96fb\u52d5\u5316\u3068\u518d\u751f\u53ef\u80fd\u30a8\u30cd\u30eb\u30ae\u30fc\u306e\u8caf\u8535\u80fd\u529b\u306e\u5897\u52a0\u306f\u3001\u3068\u3082\u306b\u96fb\u6c60\u306b\u5bfe\u3059\u308b\u9700\u8981\u306e\u5927\u5e45\u306a\u52a0\u901f\u3092\u3082\u305f\u3089\u3057\u3066\u2026","rel":"","context":"\u5206\u6790\u30fb\u6e2c\u5b9a\u95a2\u9023","block_context":{"text":"\u5206\u6790\u30fb\u6e2c\u5b9a\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/analysis\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/01\/battery-manufacturing-elemental-analysis-csm-26005_eyecatch.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/01\/battery-manufacturing-elemental-analysis-csm-26005_eyecatch.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/01\/battery-manufacturing-elemental-analysis-csm-26005_eyecatch.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/01\/battery-manufacturing-elemental-analysis-csm-26005_eyecatch.jpg?resize=700%2C400&ssl=1 2x"},"classes":[]},{"id":24108,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/cell-culture-cell-count-bid-ts-mbr-25065-2\/","url_meta":{"origin":6305,"position":3},"title":"\u3010\u7b2c6\u56de\u3011 \u30a6\u30a7\u30b9\u30bf\u30f3\u30d6\u30ed\u30c3\u30c6\u30a3\u30f3\u30b0\u6cd5\u306b\u3088\u308b \u300e\u30a8\u30af\u30bd\u30bd\u30fc\u30e0\u4e2d\u306e\u30bf\u30f3\u30d1\u30af\u8cea\uff08Protein cargo\uff09\u300f\u306e\u89e3\u6790","author":"LatB Staff","date":"2026\u5e747\u670815\u65e5","format":false,"excerpt":"\u30a8\u30af\u30bd\u30bd\u30fc\u30e0\uff08\u30a8\u30ad\u30bd\u30bd\u30fc\u30e0\uff09\u306f\u3001\u7d30\u80de\u304b\u3089\u5206\u6ccc\u3055\u308c\u308b\u5c0f\u3055\u306a\u819c\u5c0f\u80de\u3067\u3001\u6838\u9178\uff08RNA\uff0fDNA\uff09\u3060\u3051\u3067\u306a\u304f\u3001\u2026","rel":"","context":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","block_context":{"text":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/mol-bio\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/11\/cell-culture-cell-count-bid-ts-mbr-25065_eyecatch.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/11\/cell-culture-cell-count-bid-ts-mbr-25065_eyecatch.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/11\/cell-culture-cell-count-bid-ts-mbr-25065_eyecatch.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/11\/cell-culture-cell-count-bid-ts-mbr-25065_eyecatch.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/11\/cell-culture-cell-count-bid-ts-mbr-25065_eyecatch.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/11\/cell-culture-cell-count-bid-ts-mbr-25065_eyecatch.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":23239,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/ngs-gene-expression-csd-ts-bfx-25060\/","url_meta":{"origin":6305,"position":4},"title":"\u98df\u54c1\u958b\u767a\u306b\u304a\u3051\u308b\u83cc\u53e2\u89e3\u6790\u3068\u907a\u4f1d\u5b50\u767a\u73fe\u89e3\u6790\u306e\u6d3b\u7528","author":"LatB Staff","date":"2025\u5e7410\u67088\u65e5","format":false,"excerpt":"\u907a\u4f1d\u5b50\u95a2\u9023\u306e\u89e3\u6790\u6280\u8853\u304c\u7814\u7a76\u306e\u307f\u306a\u3089\u305a\u7523\u696d\u5206\u91ce\u3067\u6d3b\u7528\u3055\u308c\u308b\u3088\u3046\u306b\u306a\u308a\u3001\u5e74\u6708\u304c\u7d4c\u904e\u3059\u308b\u306b\u3064\u308c\u3066\u5fdc\u7528\u7bc4\u56f2\u3082\u2026","rel":"","context":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","block_context":{"text":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/mol-bio\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/09\/ngs-gene-expression-gsd-ts-tr-25060_eyecatch.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/09\/ngs-gene-expression-gsd-ts-tr-25060_eyecatch.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/09\/ngs-gene-expression-gsd-ts-tr-25060_eyecatch.jpg?resize=525%2C300&ssl=1 1.5x"},"classes":[]},{"id":24587,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/twin-screw-extrusion-extruder-cad-26003\/","url_meta":{"origin":6305,"position":5},"title":"\u4e8c\u8ef8\u62bc\u51fa\u6a5f\u306e\u57fa\u790e\u2468 \u5f8c\u5de5\u7a0b\u3068\u30b5\u30f3\u30d7\u30eb\u306e\u56de\u53ce \u30da\u30ec\u30bf\u30a4\u30ba","author":"LatB Staff","date":"2026\u5e741\u670822\u65e5","format":false,"excerpt":"\u66f4\u65b0\u65e5 : \u3053\u306e\u8a18\u4e8b\u306e\u8981\u70b9 \u30da\u30ec\u30bf\u30a4\u30ba\u306f\u4e8c\u8ef8\u62bc\u51fa\u6a5f\u306b\u3088\u308b\u30b3\u30f3\u30d1\u30a6\u30f3\u30c7\u30a3\u30f3\u30b0\u5f8c\u306e\u4ee3\u8868\u7684\u306a\u30b5\u30f3\u30d7\u30eb\u56de\u53ce\u6cd5\u2026","rel":"","context":"\u5206\u6790\u30fb\u6e2c\u5b9a\u95a2\u9023","block_context":{"text":"\u5206\u6790\u30fb\u6e2c\u5b9a\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/analysis\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/01\/twin-screw-extrusion-extruder-cad-26003_eyeycatch.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/01\/twin-screw-extrusion-extruder-cad-26003_eyeycatch.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/01\/twin-screw-extrusion-extruder-cad-26003_eyeycatch.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/01\/twin-screw-extrusion-extruder-cad-26003_eyeycatch.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/01\/twin-screw-extrusion-extruder-cad-26003_eyeycatch.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/01\/twin-screw-extrusion-extruder-cad-26003_eyeycatch.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]}],"jetpack_sharing_enabled":true,"amp_enabled":true,"jetpack_featured_media_url":"","_links":{"self":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/posts\/6305","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/users\/975"}],"replies":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/comments?post=6305"}],"version-history":[{"count":0,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/posts\/6305\/revisions"}],"wp:attachment":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/media?parent=6305"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/categories?post=6305"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/tags?post=6305"},{"taxonomy":"division","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/division?post=6305"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}