{"id":656,"date":"2017-03-02T00:00:00","date_gmt":"2017-03-02T00:00:00","guid":{"rendered":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/qpcr-basic38\/"},"modified":"2025-04-16T15:25:26","modified_gmt":"2025-04-16T06:25:26","slug":"qpcr-basic38","status":"publish","type":"post","link":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/qpcr-basic38\/","title":{"rendered":"\u3042\u306a\u305f\u306fTaqMan\uff1f\u305d\u308c\u3068\u3082SYBR Green\uff1f\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u306b\u304a\u3051\u308b\u86cd\u5149\u691c\u51fa\u30b7\u30b9\u30c6\u30e0\u306e\u539f\u7406"},"content":{"rendered":"<p>\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u306b\u306f\u3001\u591a\u304f\u306e\u86cd\u5149\u30b1\u30df\u30b9\u30c8\u30ea\u304c\u5b58\u5728\u3057\u307e\u3059\u3002\u4eca\u56de\u306f\u3001TaqMan Assay\u3084SYBR Green\u8272\u7d20\u30d9\u30fc\u30b9\u306e\u30a2\u30c3\u30bb\u30a4\u306a\u3069\u3001<strong>\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u306b\u304a\u3051\u308b\u86cd\u5149\u691c\u51fa\u30b7\u30b9\u30c6\u30e0\u306b\u3064\u3044\u3066\u3054\u7d39\u4ecb\u3057\u307e\u3059\u3002<\/strong><\/p>\n<h2>\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0\u86cd\u5149PCR\u30b1\u30df\u30b9\u30c8\u30ea<\/h2>\n<p><strong>\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u306b\u306f\u3001\u591a\u304f\u306e\u86cd\u5149\u30b1\u30df\u30b9\u30c8\u30ea\u304c\u5b58\u5728\u3057\u307e\u3059\u304c\u3001\u6700\u3082\u5e83\u304f\u4f7f\u7528\u3055\u308c\u3066\u3044\u308b\u306e\u306f5\u2032\u30cc\u30af\u30ec\u30a2\u30fc\u30bc\u30a2\u30c3\u30bb\u30a4\u3067\u3042\u308a\u3001\u305d\u306e\u4e2d\u3067\u3082\u6700\u3082\u30dd\u30d4\u30e5\u30e9\u30fc\u306a\u30a2\u30c3\u30bb\u30a4\u306f<a href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/life-science\/pcr\/real-time-pcr\/real-time-pcr-assays.html\/?CID=gsd_pcr_sbu_r04_jp_cp0000_pjt0000_gsd00000_0so_blg_op_awa_oc_s00_qpcr44_Social_LAB\" target=\"_blank\" rel=\"noopener noreferrer\">TaqMan Assay<\/a>\u3067\u3059\u3002<\/strong>\u4ed6\u306e\u86cd\u5149\u30b1\u30df\u30b9\u30c8\u30ea\u3067\u306f\u3001<a href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/life-science\/pcr\/real-time-pcr\/reagents-kits\/sybr-green-master-mixes.html?CID=gsd_pcr_sbu_r04_jp_cp0000_pjt0000_gsd00000_0so_blg_op_awa_oc_s00_qpcr44_Social_LAB\" target=\"_blank\" rel=\"noopener noreferrer\">Applied Biosystems\u2122 SYBR\u2122 Green\u8272\u7d20\u30d9\u30fc\u30b9\u306e\u30a2\u30c3\u30bb\u30a4<\/a>\u306a\u3069\u304c\u3042\u308a\u307e\u3059\uff08\u56f31\uff09\u3002<\/p>\n<div id=\"attachment_1797\" style=\"width: 750px\" class=\"wp-caption aligncenter\"><a href=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/qpcr-basic38-fig1.png\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-1797\" class=\"size-full wp-image-1797\" src=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/qpcr-basic38-fig1.png\" alt=\"qpcr-basic38-fig1\" width=\"740\" height=\"368\" \/><\/a><p id=\"caption-attachment-1797\" class=\"wp-caption-text\">\u56f31 \u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u306e\u86cd\u5149\u30b1\u30df\u30b9\u30c8\u30ea\u3002(A)5\u2032\u30cc\u30af\u30ec\u30a2\u30fc\u30bc\u30a2\u30c3\u30bb\u30a4\u3001(B)SYBR Green\u30a2\u30c3\u30bb\u30a4<\/p><\/div>\n<p>5\u2032\u30cc\u30af\u30ec\u30a2\u30fc\u30bc\u30a2\u30c3\u30bb\u30a4\u306f\u3001<strong>Taq DNA\u30dd\u30ea\u30e1\u30e9\u30fc\u30bc\u306e\u6301\u30645\u2032\u30cc\u30af\u30ec\u30a2\u30fc\u30bc\u6d3b\u6027<\/strong>\u304b\u3089\u547d\u540d\u3055\u308c\u307e\u3057\u305f\uff08\u56f32\uff09\u3002<\/p>\n<div id=\"attachment_1798\" style=\"width: 752px\" class=\"wp-caption aligncenter\"><a href=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/qpcr-basic38-fig2.png\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-1798\" class=\"size-full wp-image-1798\" src=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/qpcr-basic38-fig2.png\" alt=\"qpcr-basic38-fig2\" width=\"742\" height=\"338\" \/><\/a><p id=\"caption-attachment-1798\" class=\"wp-caption-text\">\u56f32 \u4ee3\u8868\u7684Taq DNA\u30dd\u30ea\u30e1\u30e9\u30fc\u30bc\u3002\u5f69\u8272\u3057\u305f\u7403\u4f53\u306f\u30bf\u30f3\u30d1\u30af\u30c9\u30e1\u30a4\u30f3\u3092\u8868\u3057\u3066\u3044\u307e\u3059\u3002<\/p><\/div>\n<p>5\u2032\u30cc\u30af\u30ec\u30a2\u30fc\u30bc\u30c9\u30e1\u30a4\u30f3\u306fDNA\u5408\u6210\u306e\u4e0b\u6d41\u306b\u5b58\u5728\u3059\u308b\u3001<strong>\u30c6\u30f3\u30d7\u30ec\u30fc\u30c8\u306b\u7d50\u5408\u3057\u305fDNA\u3092\u5206\u89e3\u3059\u308b\u3053\u3068\u304c\u53ef\u80fd<\/strong>\u3067\u3059\u30025\u2032\u30cc\u30af\u30ec\u30a2\u30fc\u30bc\u30a2\u30c3\u30bb\u30a4\u306e<strong>\u7b2c\u4e8c\u306e\u91cd\u8981\u306a\u8981\u7d20\u306fFRET\u3068\u547c\u3070\u308c\u308b\u86cd\u5149\u5171\u9cf4\u30a8\u30cd\u30eb\u30ae\u30fc\u79fb\u52d5\u73fe\u8c61<\/strong>\u3067\u3059\u3002FRET\u306b\u304a\u3044\u3066\u86cd\u5149\u8272\u7d20\u306e\u767a\u5149\u306f\u3001\u8fd1\u508d\u306b\u5b58\u5728\u3059\u308b\u3082\u3046\u4e00\u3064\u306e\u8272\u7d20\u3001\u591a\u304f\u306e\u5834\u5408\u30af\u30a8\u30f3\u30c1\u30e3\u30fc\u3068\u547c\u3070\u308c\u308b\u8272\u7d20\u306b\u3088\u308a\u3001\u5927\u304d\u304f\u4f4e\u6e1b\u3055\u308c\u307e\u3059\uff08\u56f33\uff09\u3002<\/p>\n<div id=\"attachment_1799\" style=\"width: 734px\" class=\"wp-caption aligncenter\"><a href=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/qpcr-basic38-fig3.png\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-1799\" class=\"size-full wp-image-1799\" src=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/qpcr-basic38-fig3.png\" alt=\"qpcr-basic38-fig3\" width=\"724\" height=\"302\" \/><\/a><p id=\"caption-attachment-1799\" class=\"wp-caption-text\">\u56f33 FRET\u73fe\u8c61\u3002\uff08A\uff09FRET\u73fe\u8c61\u306f\u3001\u7dd1\u8272\u86cd\u5149\u8272\u7d20\u304c\u8d64\u8272\u86cd\u5149\u8272\u7d20\u306b\u8fd1\u63a5\u3057\u3066\u3044\u308b\u6642\u306b\u8d77\u3053\u308a\u307e\u3059\u3002\uff08B\uff09FRET\u306f2\u3064\u306e\u86cd\u5149\u8272\u7d20\u304c\u8fd1\u63a5\u3057\u3066\u3044\u306a\u3044\u5834\u5408\u306b\u306f\u8d77\u3053\u308a\u307e\u305b\u3093\u3002<\/p><\/div>\n<p>FRET\u306f\u3001\u7dd1\u8272\u3068\u8d64\u8272\u306e2\u3064\u306e\u86cd\u5149\u8272\u7d20\u306b\u3088\u3063\u3066\u8aac\u660e\u3067\u304d\u307e\u3059\u3002\u7dd1\u8272\u306e\u5149\u306f\u8d64\u8272\u306e\u5149\u3088\u308a\u6ce2\u9577\u304c\u77ed\u3044\u305f\u3081\u3001\u7dd1\u8272\u306e\u86cd\u5149\u8272\u7d20\u306f\u8d64\u8272\u3068\u6bd4\u8f03\u3057\u3066\u3088\u308a\u9ad8\u3044\u86cd\u5149\u767a\u5149\u30a8\u30cd\u30eb\u30ae\u30fc\u3092\u6709\u3057\u3066\u3044\u307e\u3059\u3002\u8d64\u8272\u8272\u7d20\u304c\u7dd1\u8272\u8272\u7d20\u306e\u8fd1\u508d\u306b\u5b58\u5728\u3059\u308b\u5834\u5408\u3001\u7dd1\u8272\u306e\u8272\u7d20\u306e\u52b1\u8d77\u306b\u3088\u308a\u7dd1\u8272\u306e\u86cd\u5149\u767a\u5149\u30a8\u30cd\u30eb\u30ae\u30fc\u304c\u8d64\u8272\u306e\u8272\u7d20\u306b\u79fb\u52d5\u3057\u307e\u3059\u3002\u8a00\u3044\u63db\u3048\u308b\u3068\u3001\u30a8\u30cd\u30eb\u30ae\u30fc\u304c\u9ad8\u30ec\u30d9\u30eb\u304b\u3089\u4f4e\u30ec\u30d9\u30eb\u306b\u79fb\u52d5\u3057\u307e\u3059\u3002\u7d50\u679c\u3068\u3057\u3066\u3001\u7dd1\u8272\u306e\u8272\u7d20\u304b\u3089\u306e\u30b7\u30b0\u30ca\u30eb\u306f\u6291\u5236\u3001\u307e\u305f\u306f\u300c\u6d88\u5149\u300d\u3055\u308c\u307e\u3059\u3002\u3057\u304b\u3057\u30012\u3064\u306e\u8272\u7d20\u304c\u8fd1\u63a5\u3057\u3066\u3044\u306a\u3044\u5834\u5408\u306b\u306f\u3001FRET\u306f\u8d77\u3053\u3089\u305a\u3001\u7dd1\u8272\u306e\u8272\u7d20\u306f\u5b8c\u5168\u306a\u30b7\u30b0\u30ca\u30eb\u3092\u767a\u3057\u307e\u3059\u3002<\/p>\n<p>\u30bf\u30fc\u30b2\u30c3\u30c8\u306e\u691c\u51fa\u307e\u305f\u306f\u5b9a\u91cf\u306e\u305f\u3081\u306e\u5178\u578b\u7684\u306a5\u2032\u30cc\u30af\u30ec\u30a2\u30fc\u30bc\u30a2\u30c3\u30bb\u30a4\u306b\u306f\u3001<strong>2\u3064\u306ePCR\u30d7\u30e9\u30a4\u30de\u30fc\u3068TaqMan\u30d7\u30ed\u30fc\u30d6<\/strong>\u304c\u542b\u307e\u308c\u307e\u3059\uff08\u56f34\uff09\u3002<\/p>\n<div id=\"attachment_1800\" style=\"width: 728px\" class=\"wp-caption aligncenter\"><a href=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/qpcr-basic38-fig4.png\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-1800\" class=\"size-full wp-image-1800\" src=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/qpcr-basic38-fig4.png\" alt=\"qpcr-basic38-fig4\" width=\"718\" height=\"274\" \/><\/a><p id=\"caption-attachment-1800\" class=\"wp-caption-text\">\u56f34 TaqMan\u30d7\u30ed\u30fc\u30d6\u3002TaqMan\u30d7\u30ed\u30fc\u30d6\u306f\u907a\u4f1d\u5b50\u7279\u7570\u7684\u306a\u914d\u5217\u3092\u6709\u3057\u30012\u3064\u306ePCR\u30d7\u30e9\u30a4\u30de\u30fc\u9593\u306e\u30bf\u30fc\u30b2\u30c3\u30c8\u306b\u7d50\u5408\u3059\u308b\u3088\u3046\u306b\u30c7\u30b6\u30a4\u30f3\u3055\u308c\u3066\u3044\u307e\u3059\u3002TaqMan\u30d7\u30ed\u30fc\u30d6\u306e5\u2032\u672b\u7aef\u306b\u306f\u30bf\u30fc\u30b2\u30c3\u30c8\u306e\u5897\u5e45\u3092\u30ec\u30dd\u30fc\u30c8\u3059\u308b\u86cd\u5149\u8272\u7d20\u3067\u3042\u308b\u3001\u300c\u30ec\u30dd\u30fc\u30bf\u30fc\u300d\u304c\u7d50\u5408\u3057\u3066\u3044\u307e\u3059\u3002\u30d7\u30ed\u30fc\u30d6\u306e3\u2032\u672b\u7aef\u306b\u306f\u30ec\u30dd\u30fc\u30bf\u30fc\u304b\u3089\u306e\u86cd\u5149\u3092\u6d88\u5149\u3059\u308b\u30af\u30a8\u30f3\u30c1\u30e3\u30fc\u304c\u7d50\u5408\u3057\u3066\u3044\u307e\u3059\u3002\u30af\u30a8\u30f3\u30c1\u30e3\u30fc\u306f\u3001\u30d7\u30ed\u30fc\u30d6\u306e3\u2032\u672b\u7aef\u3092\u30d6\u30ed\u30c3\u30af\u3057\u3066\u71b1\u5b89\u5b9a\u6027DNA\u30dd\u30ea\u30e1\u30e9\u30fc\u30bc\u306b\u3088\u308b\u4f38\u9577\u3092\u963b\u6b62\u3059\u308b\u5f79\u76ee\u3082\u679c\u305f\u3057\u3066\u3044\u307e\u3059\u3002<\/p><\/div>\n<p>PCR\u306e\u958b\u59cb\u524d\u306b\u304a\u3044\u3066\u306f\u3001TaqMan\u30d7\u30ed\u30fc\u30d6\u306f\u672a\u5909\u5316\u3067\u3001\u30ec\u30dd\u30fc\u30bf\u30fc\u3068\u30af\u30a8\u30f3\u30c1\u30e3\u30fc\u304c\u8fd1\u63a5\u3057\u3066\u3044\u308b\u305f\u3081FRET\u3092\u751f\u3058\u307e\u3059\uff08\u56f35\uff09\u3002\u3053\u306e\u305f\u3081\u3001\u30ec\u30dd\u30fc\u30bf\u30fc\u306e\u30b7\u30b0\u30ca\u30eb\u306fPCR\u53cd\u5fdc\u306e\u524d\u306e\u6bb5\u968e\u3067\u306f\u6d88\u5149\u3055\u308c\u3066\u3044\u307e\u3059\u3002<\/p>\n<div id=\"attachment_1801\" style=\"width: 348px\" class=\"wp-caption aligncenter\"><a href=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/qpcr-basic38-fig5.png\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-1801\" class=\"size-full wp-image-1801\" src=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/qpcr-basic38-fig5.png\" alt=\"qpcr-basic38-fig5\" width=\"338\" height=\"254\" \/><\/a><p id=\"caption-attachment-1801\" class=\"wp-caption-text\">\u56f35 \u6eb6\u6db2\u4e2d\u306eTaqMan\u30d7\u30ed\u30fc\u30d6\uff1aR\u306f\u30ec\u30dd\u30fc\u30bf\u30fc\u8272\u7d20\u3092\u3001Q\u306f\u30af\u30a8\u30f3\u30c1\u30e3\u30fc\u5206\u5b50\u3092\u3001\u6a59\u8272\u306e\u7dda\u306f\u30aa\u30ea\u30b4\u30cc\u30af\u30ec\u30aa\u30c1\u30c9\u3092\u793a\u3057\u3066\u3044\u307e\u3059\u3002<\/p><\/div>\n<p>PCR\u306e\u904e\u7a0b\u306b\u304a\u3044\u3066\u3001\u30d7\u30e9\u30a4\u30de\u30fc\u3068\u30d7\u30ed\u30fc\u30d6\u304c\u30bf\u30fc\u30b2\u30c3\u30c8\u306b\u30a2\u30cb\u30fc\u30eb\u3057\u307e\u3059\u3002DNA\u30dd\u30ea\u30e1\u30e9\u30fc\u30bc\u304c\u30d7\u30e9\u30a4\u30de\u30fc\u304b\u3089\u30d7\u30ed\u30fc\u30d6\u306e\u4e0a\u6d41\u307e\u3067\u4f38\u9577\u3057\u305f\u3068\u304d\u3001\u3082\u3057\u30d7\u30ed\u30fc\u30d6\u304c\u6b63\u3057\u3044\u30bf\u30fc\u30b2\u30c3\u30c8\u306b\u7d50\u5408\u3057\u3066\u3044\u308c\u3070\u3001\u30dd\u30ea\u30e1\u30e9\u30fc\u30bc\u306e5\u2032\u30cc\u30af\u30ec\u30a2\u30fc\u30bc\u6d3b\u6027\u306b\u3088\u308a\u30d7\u30ed\u30fc\u30d6\u304c\u5207\u65ad\u3055\u308c\u3001\u30ec\u30dd\u30fc\u30bf\u30fc\u8272\u7d20\u3092\u542b\u3093\u3060\u65ad\u7247\u304c\u653e\u51fa\u3055\u308c\u307e\u3059\u3002\u4e00\u5ea6\u5207\u65ad\u304c\u8d77\u304d\u308b\u3068\u30ec\u30dd\u30fc\u30bf\u30fc\u3068\u30af\u30a8\u30f3\u30c1\u30e3\u30fc\u306f\u3082\u306f\u3084\u304a\u4e92\u3044\u306b\u8fd1\u63a5\u3057\u306a\u304f\u306a\u308a\u307e\u3059\u306e\u3067\u3001\u653e\u51fa\u3055\u308c\u305f\u30ec\u30dd\u30fc\u30bf\u30fc\u5206\u5b50\u306f\u6d88\u5149\u3055\u308c\u307e\u305b\u3093\u3002<\/p>\n<h2>5\u2032\u30cc\u30af\u30ec\u30a2\u30fc\u30bc\u30a2\u30c3\u30bb\u30a4\u306e\u7279\u7570\u6027<\/h2>\n<p><strong>\u30a2\u30c3\u30bb\u30a4\u306e\u7279\u7570\u6027\u3068\u306f\u3001\u5f97\u3089\u308c\u305f\u7d50\u679c\u306b\u304a\u3044\u3066\u30a2\u30c3\u30bb\u30a4\u304c\u3069\u306e\u7a0b\u5ea6\u30bf\u30fc\u30b2\u30c3\u30c8\u304b\u3089\u306e\u30b7\u30b0\u30ca\u30eb\u3092\u542b\u307f\u3001\u975e\u30bf\u30fc\u30b2\u30c3\u30c8\u304b\u3089\u306e\u30b7\u30b0\u30ca\u30eb\u3092\u6392\u9664\u3057\u3066\u3044\u308b\u304b\u3092\u793a\u3057\u307e\u3059\u3002\u7279\u7570\u6027\u306f\u3001\u9593\u9055\u3044\u306a\u304f\u30a2\u30c3\u30bb\u30a4\u306e\u6700\u3082\u91cd\u8981\u306a\u8981\u7d20\u3067\u3059\u3002<\/strong>5\u2032\u30cc\u30af\u30ec\u30a2\u30fc\u30bc\u30a2\u30c3\u30bb\u30a4\u306e\u7279\u7570\u6027\u3092\u304a\u3073\u3084\u304b\u3059\u6700\u5927\u306e\u8981\u56e0\u3068\u306a\u308b\u306e\u304c\u76f8\u540c\u914d\u5217\u3067\u3059\u3002\u76f8\u540c\u914d\u5217\u306f\u3001\u30bf\u30fc\u30b2\u30c3\u30c8\u3068\u985e\u4f3c\u3057\u305f\u914d\u5217\u3092\u6709\u3059\u308b\u907a\u4f1d\u5b50\u3067\u3059\u304c\u76ee\u7684\u3068\u3059\u308b\u30bf\u30fc\u30b2\u30c3\u30c8\u3067\u306f\u3042\u308a\u307e\u305b\u3093\u3002\u76f8\u540c\u914d\u5217\u306f\u540c\u7a2e\u9593\u304a\u3088\u3073\u95a2\u9023\u7a2e\u9593\u306b\u304a\u3044\u3066\u6975\u3081\u3066\u3088\u304f\u898b\u3089\u308c\u307e\u3059\u3002<\/p>\n<p>5\u2032\u30cc\u30af\u30ec\u30a2\u30fc\u30bc\u30a2\u30c3\u30bb\u30a4\u306b\u306f\u3001\u30d7\u30e9\u30a4\u30de\u30fc\u30bb\u30c3\u30c8\u304a\u3088\u3073\u30d7\u30ed\u30fc\u30d6\u3068\u3044\u30462\u7a2e\u985e\u306e\u30c4\u30fc\u30eb\u3092\u4f7f\u7528\u3057\u307e\u3059\u3002<strong>\u30d7\u30e9\u30a4\u30de\u30fc\u3067\u6700\u5927\u9650\u306e\u7279\u7570\u6027\u3092\u78ba\u4fdd\u3059\u308b\u305f\u3081\u306b\u306f\u3001\u30bf\u30fc\u30b2\u30c3\u30c8\u3068\u76f8\u540c\u914d\u5217\u306e\u9593\u306e\u30df\u30b9\u30de\u30c3\u30c1\u304c\u30d7\u30e9\u30a4\u30de\u30fc\u306e3\u2032\u672b\u7aef\u5869\u57fa\u306b\u4f4d\u7f6e\u3057\u3066\u3044\u308b\u3053\u3068\u304c\u5fc5\u8981<\/strong>\u3067\u3059\u3002\u30df\u30b9\u30de\u30c3\u30c1\u304c3\u2032\u672b\u7aef\u304b\u3089\u96e2\u308c\u305f\u4f4d\u7f6e\u306b\u3042\u308b\u5834\u5408\u306f\u7279\u7570\u6027\u306b\u307b\u3068\u3093\u3069\u52b9\u679c\u3092\u767a\u63ee\u3057\u307e\u305b\u3093\u3002\u3053\u308c\u3068\u306f\u5bfe\u7167\u7684\u306b\u3001<a href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/life-science\/oligonucleotides-primers-probes-genes\/applied-biosystems-custom-primers-probes\/taqman-mgb-probe.html?CID=gsd_pcr_sbu_r04_jp_cp0000_pjt0000_gsd00000_0so_blg_op_awa_oc_s00_qpcr44_Social_LAB\" target=\"_blank\" rel=\"noopener noreferrer\">Applied Biosystems\u2122 TaqMan\u2122 MGB\u30d7\u30ed\u30fc\u30d6<\/a>\u306f\u3069\u3053\u306b\u30df\u30b9\u30de\u30c3\u30c1\u304c\u5165\u3063\u3066\u3082\u9ad8\u3044\u7279\u7570\u6027\u3092\u78ba\u4fdd\u3067\u304d\u307e\u3059\u3002TaqMan MGB\u30d7\u30ed\u30fc\u30d6\u306f\u30d7\u30e9\u30a4\u30de\u30fc\u3088\u308a\u3082\u5f37\u529b\u306a\u7279\u7570\u6027\u306b\u512a\u308c\u305f\u30c4\u30fc\u30eb\u3067\u3059\u3002<\/p>\n<p>\u4f8b\u3048\u3070\u3001<strong>\u30d7\u30e9\u30a4\u30de\u30fc\u7d50\u5408\u90e8\u4f4d\u306b1\u30012\u5869\u57fa\u306e\u30e9\u30f3\u30c0\u30e0\u30df\u30b9\u30de\u30c3\u30c1\u304c\u5b58\u5728\u3057\u3066\u3044\u3066\u3082\u3001DNA\u30dd\u30ea\u30e1\u30e9\u30fc\u30bc\u304c\u76f8\u540c\u914d\u5217\u306b\u7d50\u5408\u3057\u305f\u30d7\u30e9\u30a4\u30de\u30fc\u304b\u3089\u52b9\u7387\u3088\u304f\u4f38\u9577\u3059\u308b\u53ef\u80fd\u6027\u306f\u975e\u5e38\u306b\u9ad8\u3044<\/strong>\u3067\u3059\u3002\u30df\u30b9\u30de\u30c3\u30c1\u30d7\u30e9\u30a4\u30de\u30fc\u304b\u3089DNA\u30dd\u30ea\u30e1\u30e9\u30fc\u30bc\u304c1\u30012\u5869\u57fa\u4f38\u9577\u3059\u308b\u3068\u3001\u76f8\u540c\u914d\u5217\u306b\u7d50\u5408\u3057\u305f\u30d7\u30e9\u30a4\u30de\u30fc\u304c\u5b89\u5b9a\u5316\u3055\u308c\u307e\u3059\u3002\u305d\u306e\u7d50\u679c\u3001\u76f8\u540c\u914d\u5217\u306b\u7d50\u5408\u3057\u305f\u30d7\u30e9\u30a4\u30de\u30fc\u306f\u3001\u76ee\u7684\u306e\u30bf\u30fc\u30b2\u30c3\u30c8\u306b\u7d50\u5408\u3057\u305f\u30d7\u30e9\u30a4\u30de\u30fc\u3068\u540c\u7b49\u306b\u5b89\u5b9a\u3057\u3066\u7d50\u5408\u3057\u307e\u3059\u3002\u3053\u306e\u6642\u70b9\u3067\u306f\u3001\u3082\u306f\u3084DNA\u30dd\u30ea\u30e1\u30e9\u30fc\u30bc\u304c\u76f8\u540c\u914d\u5217\u306e\u30b3\u30d4\u30fc\u3092\u5408\u6210\u3057\u7d9a\u3051\u308b\u306e\u3092\u9632\u3050\u3053\u3068\u306f\u4e0d\u53ef\u80fd\u3067\u3059\u3002<\/p>\n<p>\u3053\u308c\u3068\u306f\u5bfe\u7167\u7684\u306b\u3001<strong>TaqMan\u30d7\u30ed\u30fc\u30d6\u7d50\u5408\u90e8\u4f4d\u306e5\u2032\u672b\u7aef\u306b\u304a\u3051\u308b\u30df\u30b9\u30de\u30c3\u30c1\u306f\u30013\u2032\u672b\u7aef\u306b\u30af\u30a8\u30f3\u30c1\u30e3\u30fc\u8272\u7d20\u304c\u5b58\u5728\u3059\u308b\u305f\u3081\u3001DNA\u30dd\u30ea\u30e1\u30e9\u30fc\u30bc\u53cd\u5fdc\u306b\u3088\u308a\u4f38\u9577\u304a\u3088\u3073\u5b89\u5b9a\u5316\u3055\u308c\u308b\u53ef\u80fd\u6027\u306f\u3042\u308a\u307e\u305b\u3093<\/strong>\u3002TaqMan MGB\u30d7\u30ed\u30fc\u30d6\u306e\u7d50\u5408\u90e8\u4f4d\u306b\u30df\u30b9\u30de\u30c3\u30c1\u304c\u5b58\u5728\u3059\u308b\u3068\u30d7\u30ed\u30fc\u30d6\u306e\u7d50\u5408\u5f37\u5ea6\u304c\u4f4e\u4e0b\u3059\u308b\u305f\u3081\u3001\u30d7\u30ed\u30fc\u30d6\u306f\u5207\u65ad\u3055\u308c\u305a\u306b\u904a\u96e2\u3057\u307e\u3059\u3002\u904a\u96e2\u3057\u305f\u30d7\u30ed\u30fc\u30d6\u306f\u6d88\u5149\u3055\u308c\u305f\u72b6\u614b\u306e\u307e\u307e\u3067\u3059\u306e\u3067\u3001PCR\u30b5\u30a4\u30af\u30eb\u306e\u6700\u5f8c\u3067\u30c7\u30fc\u30bf\u3092\u53ce\u96c6\u3059\u308b\u6642\u70b9\u306b\u304a\u3044\u3066\u306f\u3001\u305f\u3068\u3048\u76f8\u540c\u914d\u5217\u304c\u5897\u5e45\u3057\u3066\u3044\u3066\u3082\u3001\u5f97\u3089\u308c\u308b\u30b7\u30b0\u30ca\u30eb\u306f\u30bf\u30fc\u30b2\u30c3\u30c8\u304b\u3089\u751f\u6210\u3055\u308c\u305f\u3082\u306e\u3067\u3042\u308a\u76f8\u540c\u914d\u5217\u306b\u7531\u6765\u3059\u308b\u3082\u306e\u3067\u306f\u3042\u308a\u307e\u305b\u3093\u3002<\/p>\n<p>\u76f8\u540c\u914d\u5217\u306b\u52a0\u3048\u3066\u3001PCR\u306b\u304a\u3044\u3066\u306f\u3001\u30d7\u30e9\u30a4\u30de\u30fc\u304cDNA\u8a66\u6599\u306e\u30e9\u30f3\u30c0\u30e0\u306a\u90e8\u4f4d\u306b\u7d50\u5408\u3059\u308b\u3053\u3068\u306b\u3088\u308a\u751f\u6210\u3059\u308b\u7523\u7269\u3084\u3001\u6642\u306b\u306f\u30d7\u30e9\u30a4\u30de\u30fc\u540c\u58eb\u304c\u7d50\u5408\u3057\u3066\u751f\u6210\u3059\u308b\u3044\u308f\u3086\u308b\u300c\u30d7\u30e9\u30a4\u30de\u30fc\u30c0\u30a4\u30de\u30fc\u300d\u306a\u3069\u306e\u975e\u7279\u7570\u7684\u7523\u7269\u304c\u751f\u6210\u3059\u308b\u53ef\u80fd\u6027\u3082\u3042\u308a\u307e\u3059\u3002<strong>\u975e\u7279\u7570\u7684\u7523\u7269\u306f\u30bf\u30fc\u30b2\u30c3\u30c8\u3068\u7121\u95a2\u4fc2\u3067\u3042\u308b\u305f\u3081TaqMan\u30d7\u30ed\u30fc\u30d6\u7d50\u5408\u90e8\u4f4d\u304c\u306a\u304f\u3001\u3053\u306e\u305f\u3081\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u30c7\u30fc\u30bf\u306b\u306f\u5f71\u97ff\u3057\u307e\u305b\u3093<\/strong>\u3002<\/p>\n<h2>TaqMan\u30d7\u30ed\u30fc\u30d6\u306e\u30bf\u30a4\u30d7<\/h2>\n<p><strong>TaqMan\u30d7\u30ed\u30fc\u30d6\u306f\u3001MGB\u304a\u3088\u3073\u975eMGB\u306e2\u3064\u306e\u30bf\u30a4\u30d7\u306b\u5206\u985e\u3067\u304d\u307e\u3059<\/strong>\u3002\u521d\u671f\u306eTaqMan\u30d7\u30ed\u30fc\u30d6\u306f\u300c\u975eMGB\u300d\u306b\u5206\u985e\u3055\u308c\u307e\u3059\u3002\u3053\u308c\u3089\u306e\u30d7\u30ed\u30fc\u30d6\u3067\u306f\u3001\u30af\u30a8\u30f3\u30c1\u30e3\u30fc\u3068\u3057\u3066Invitrogen\u2122 TAMRA\u2122 \u8272\u7d20\u3092\u4f7f\u7528\u3057\u3066\u3044\u307e\u3059\u3002\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u306e\u958b\u767a\u306e\u521d\u671f\u306e\u6bb5\u968e\u306b\u304a\u3044\u3066\u3001\u8a73\u7d30\u306a\u8a66\u9a13\u3092\u884c\u3063\u305f\u7d50\u679c\u3001TaqMan\u30d7\u30ed\u30fc\u30d6\u3092\u5207\u65ad\u3055\u305b\u308b\u305f\u3081\u306bPCR\u30d7\u30e9\u30a4\u30de\u30fc\u3088\u308a\u3082\u8457\u3057\u304f\u9ad8\u3044\u30a2\u30cb\u30fc\u30ea\u30f3\u30b0\u6e29\u5ea6\u3092\u5fc5\u8981\u3068\u3059\u308b\u3053\u3068\u304c\u5224\u660e\u3057\u307e\u3057\u305f\u3002\u3053\u306e\u305f\u3081\u3001TaqMan\u30d7\u30ed\u30fc\u30d6\u306f\u30d7\u30e9\u30a4\u30de\u30fc\u3088\u308a\u3082\u9577\u304f\u306a\u3063\u3066\u3044\u307e\u3059\u3002\u3053\u306e\u3088\u3046\u306b\u9577\u3044\u30d7\u30ed\u30fc\u30d6\u306b1\u5869\u57fa\u306e\u30df\u30b9\u30de\u30c3\u30c1\u304c\u3042\u3063\u3066\u3082\u30d7\u30ed\u30fc\u30d6\u7d50\u5408\u306b\u5bfe\u3059\u308b\u5f71\u97ff\u304c\u6bd4\u8f03\u7684\u5c0f\u3055\u3044\u305f\u3081\u3001\u5207\u65ad\u3055\u308c\u308b\u53ef\u80fd\u6027\u304c\u9ad8\u304f\u306a\u308a\u307e\u3059\u3002<\/p>\n<p>\u3057\u304b\u3057\u3001\u771f\u6838\u751f\u7269\u306b\u304a\u3051\u308b\u907a\u4f1d\u5b50\u767a\u73fe\u3084\u4e00\u5869\u57fa\u591a\u578b\u7b49\u306e\u9ad8\u5ea6\u306a\u907a\u4f1d\u7684\u8907\u96d1\u6027\u306b\u95a2\u9023\u3059\u308b\u591a\u304f\u306e\u30a2\u30d7\u30ea\u30b1\u30fc\u30b7\u30e7\u30f3\u306b\u304a\u3044\u3066\u306f\u3001\u3088\u308a\u9ad8\u3044\u7279\u7570\u6027\u304c\u5fc5\u8981\u3067\u3059\u3002\u305d\u306e\u5f8c<strong>TaqMan \u30d7\u30ed\u30fc\u30d6\u6280\u8853\u3092\u6539\u826f\u3059\u308b\u3053\u3068\u306b\u3088\u308aTaqMan MGB\u30d7\u30ed\u30fc\u30d6\u304c\u751f\u307e\u308c\u307e\u3057\u305f<\/strong>\u3002TaqMan MGB\u30d7\u30ed\u30fc\u30d6\u306f\u305d\u306e3\u2032\u672b\u7aef\u306b\u30de\u30a4\u30ca\u30fc\u30b0\u30eb\u30fc\u30d6\u7d50\u5408\uff08MGB\uff09\u5206\u5b50\u3092\u6709\u3057\u3066\u3044\u307e\u3059\u3002\u30d7\u30ed\u30fc\u30d6\u304c\u30bf\u30fc\u30b2\u30c3\u30c8\u306b\u7d50\u5408\u3059\u308b\u90e8\u5206\u306eDNA\u306b\u77ed\u3044\u30de\u30a4\u30ca\u30fc\u30b0\u30eb\u30fc\u30d6\u304c\u5f62\u6210\u3055\u308c\u3001MGB\u5206\u5b50\u304c\u7d50\u5408\u3057\u3066Tm \u304c\u4e0a\u6607\u3059\u308b\u3053\u3068\u306b\u3088\u308a\u3001\u30d7\u30ed\u30fc\u30d6\u306e\u7d50\u5408\u304c\u5f37\u5316\u3055\u308c\u307e\u3059\u3002\u7d50\u679c\u3068\u3057\u3066\u3001TaqMan MGB\u30d7\u30ed\u30fc\u30d6\u306f\u3001\u30d7\u30e9\u30a4\u30de\u30fc\u3088\u308a\u3082\u304b\u306a\u308a\u77ed\u304f\u3059\u308b\u3053\u3068\u304c\u53ef\u80fd\u3067\u3059\u3002MGB\u306e\u5b58\u5728\u306b\u3088\u308a\u3001TaqMan MGB\u30d7\u30ed\u30fc\u30d6\u306fTaqMan\u30d7\u30ed\u30fc\u30d6\u3088\u308a\u3082\u77ed\u3044\u306b\u3082\u304b\u304b\u308f\u3089\u305aTm \u304c\u9ad8\u304f\u306a\u3063\u3066\u3044\u307e\u3059\u3002\u3053\u306e\u305f\u3081\u3001<strong>TaqMan MGB\u30d7\u30ed\u30fc\u30d6\u306f\u3088\u308a\u9ad8\u3044\u6e29\u5ea6\u306b\u304a\u3044\u3066\u3001\u30d7\u30e9\u30a4\u30de\u30fc\u3088\u308a\u3082\u9ad8\u3044\u7279\u7570\u6027\u3092\u3082\u3063\u3066\u30bf\u30fc\u30b2\u30c3\u30c8\u306b\u7d50\u5408\u3059\u308b\u3053\u3068\u304c\u53ef\u80fd<\/strong>\u3068\u306a\u3063\u3066\u3044\u307e\u3059\u3002TaqMan MGB\u30d7\u30ed\u30fc\u30d6\u3067\u306f\u3001\u30d7\u30ed\u30fc\u30d6\u304c\u6bd4\u8f03\u7684\u77ed\u3044\u305f\u30811\u5869\u57fa\u306e\u30df\u30b9\u30de\u30c3\u30c1\u304c\u3088\u308a\u5927\u304d\u306a\u5f71\u97ff\u3092\u4e0e\u3048\u307e\u3059\u3002\u3053\u306e\u9ad8\u3044\u7279\u7570\u6027\u306e\u305f\u3081\u3001<strong>TaqMan MGB\u30d7\u30ed\u30fc\u30d6\u306f\u6700\u3082\u9ad8\u5ea6\u306a\u907a\u4f1d\u5b50\u89e3\u6790\u3078\u306e\u4f7f\u7528\u304c\u63a8\u5968\u3055\u308c\u3066\u3044\u307e\u3059<\/strong>\u3002<\/p>\n<h2>TaqMan\u30d7\u30ed\u30fc\u30d6\u30b7\u30b0\u30ca\u30eb\u751f\u6210<\/h2>\n<p><strong>TaqMan\u30d7\u30ed\u30fc\u30d6\u304a\u3088\u3073TaqMan MGB\u30d7\u30ed\u30fc\u30d6\u306e\u3044\u305a\u308c\u3082\u3001\u30b7\u30b0\u30ca\u30eb\u751f\u6210\u306f\u540c\u69d8\u306e\u30d1\u30bf\u30fc\u30f3\u3092\u793a\u3057\u307e\u3059<\/strong>\u3002PCR\u306e\u521d\u671f\u306e\u30b5\u30a4\u30af\u30eb\u306b\u304a\u3044\u3066\u306f\u3001\u4f4e\u30ec\u30d9\u30eb\u306e\u6d88\u5149\u3055\u308c\u305f\u30ec\u30dd\u30fc\u30bf\u30fc\u30b7\u30b0\u30ca\u30eb\u306e\u307f\u304c\u691c\u51fa\u3055\u308c\u307e\u3059\u3002\u3053\u306e\u521d\u671f\u30c7\u30fc\u30bf\u306f\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u30bd\u30d5\u30c8\u30a6\u30a7\u30a2\u306b\u304a\u3044\u3066\u306f\u81ea\u52d5\u7684\u306b\u30bc\u30ed\u306b\u5dee\u3057\u5f15\u304b\u308c\u3001\u300c\u30d9\u30fc\u30b9\u30e9\u30a4\u30f3\u300d\u3068\u547c\u3070\u308c\u307e\u3059\u3002\u3082\u3057\u8a66\u6599\u306b\u30bf\u30fc\u30b2\u30c3\u30c8\u304c\u542b\u307e\u308c\u3066\u3044\u308c\u3070\u3001\u5341\u5206\u306a\u91cf\u306e\u5207\u65ad\u30d7\u30ed\u30fc\u30d6\u304c\u84c4\u7a4d\u3057\u3001\u30d9\u30fc\u30b9\u30e9\u30a4\u30f3\u3092\u8d85\u3048\u308b\u5897\u5e45\u30b7\u30b0\u30ca\u30eb\u304c\u73fe\u308c\u307e\u3059\u3002\u5897\u5e45\u30b7\u30b0\u30ca\u30eb\u304c\u51fa\u73fe\u3059\u308b\u30dd\u30a4\u30f3\u30c8\u306f\u3001\u30bf\u30fc\u30b2\u30c3\u30c8\u306e\u521d\u671f\u91cf\u306b\u53cd\u6bd4\u4f8b\u3057\u3066\u3044\u307e\u3059\u3002<\/p>\n<h2>SYBR Green\u8272\u7d20<\/h2>\n<p><strong>SYBR Green I \u8272\u7d20\u306f\u3001\u3059\u3079\u3066\u306e\u4e8c\u672c\u9396DNA\u306e\u30de\u30a4\u30ca\u30fc\u30b0\u30eb\u30fc\u30d6\u306b\u7d50\u5408\u3059\u308b\u86cd\u5149DNA\u7d50\u5408\u8272\u7d20\u3067\u3059<\/strong>\u3002DNA\u306b\u7d50\u5408\u3057\u305fSYBR Green \u8272\u7d20\u304c\u52b1\u8d77\u3059\u308b\u3068\u3001\u975e\u7d50\u5408\u6027\u306e\u8272\u7d20\u3088\u308a\u3082\u306f\u308b\u304b\u306b\u5f37\u3044\u86cd\u5149\u30b7\u30b0\u30ca\u30eb\u3092\u767a\u751f\u3057\u307e\u3059\u3002SYBR Green\u8272\u7d20\u3092\u4f7f\u7528\u3059\u308b\u30a2\u30c3\u30bb\u30a4\u306f\u901a\u5e382\u7a2e\u985e\u306ePCR\u30d7\u30e9\u30a4\u30de\u30fc\u3092\u7528\u3044\u307e\u3059\u3002\u7406\u60f3\u7684\u306a\u6761\u4ef6\u4e0b\u3067\u306f\u3001SYBR Green\u8272\u7d20\u30a2\u30c3\u30bb\u30a4\u306f\u3001TaqMan\u30d7\u30ed\u30fc\u30d6\u3068\u540c\u69d8\u306e\u5897\u5e45\u30d1\u30bf\u30fc\u30f3\u3092\u793a\u3057\u307e\u3059\u3002PCR\u306e\u521d\u671f\u306e\u30b5\u30a4\u30af\u30eb\u306b\u304a\u3044\u3066\u306f\u6c34\u5e73\u306a\u30d9\u30fc\u30b9\u30e9\u30a4\u30f3\u304c\u89b3\u5bdf\u3055\u308c\u307e\u3059\u3002\u8a66\u6599\u4e2d\u306b\u30bf\u30fc\u30b2\u30c3\u30c8\u304c\u5b58\u5728\u3059\u308b\u3068\u3001\u3042\u308b\u6642\u70b9\u3067\u5341\u5206\u306a\u91cf\u306ePCR\u7523\u7269\u304c\u84c4\u7a4d\u3055\u308c\u3001\u5897\u5e45\u30b7\u30b0\u30ca\u30eb\u304c\u51fa\u73fe\u3057\u307e\u3059\u3002<\/p>\n<h2>SYBR Green\u30a2\u30c3\u30bb\u30a4\u306e\u7279\u7570\u6027<\/h2>\n<p><strong>SYBR Green\u30a2\u30c3\u30bb\u30a4\u306b\u304a\u3044\u3066\u306fTaqMan\u30d7\u30ed\u30fc\u30d6\u306e\u7279\u7570\u6027\u3092\u5229\u7528\u3059\u308b\u3053\u3068\u304c\u4e0d\u53ef\u80fd\u3067\u3001\u3053\u306e\u305f\u3081\u7279\u7570\u6027\u304c\u3088\u308a\u5927\u304d\u306a\u554f\u984c\u3067\u3059<\/strong>\u3002SYBR Green\u8272\u7d20\u306f\u30bf\u30fc\u30b2\u30c3\u30c8\u307e\u305f\u306f\u975e\u30bf\u30fc\u30b2\u30c3\u30c8\u306e\u3059\u3079\u3066\u306e\u5897\u5e45\u7523\u7269\u306b\u7d50\u5408\u3057\u3001\u305d\u306e\u30b7\u30b0\u30ca\u30eb\u304c\u3059\u3079\u3066\u7a4d\u7b97\u3055\u308c\u3066\u4e00\u3064\u306e\u5897\u5e45\u30d7\u30ed\u30c3\u30c8\u304c\u751f\u6210\u3055\u308c\u307e\u3059\u3002SYBR Green \u5897\u5e45\u30d7\u30ed\u30c3\u30c8\u306e\u30d1\u30bf\u30fc\u30f3\u304b\u3089\u7279\u7570\u6027\u306e\u8a55\u4fa1\u3092\u3059\u308b\u3053\u3068\u306f\u4e0d\u53ef\u80fd\u3067\u3059\u3002\u5897\u5e45\u304c\u30bf\u30fc\u30b2\u30c3\u30c8\u3001\u975e\u30bf\u30fc\u30b2\u30c3\u30c8\u307e\u305f\u306f\u305d\u308c\u3089\u306e\u6df7\u5408\u7269\u304b\u3089\u306a\u308b\u5834\u5408\u306e\u3044\u305a\u308c\u306b\u304a\u3044\u3066\u3082\u3001\u30d7\u30ed\u30c3\u30c8\u306f\u540c\u3058\u30d1\u30bf\u30fc\u30f3\u3092\u793a\u3057\u307e\u3059\u3002SYBR Green\u30a2\u30c3\u30bb\u30a4\u306b\u3088\u308a\u5897\u5e45\u7523\u7269\u304c\u751f\u6210\u3057\u3066\u3082\u3001\u305d\u306e\u30b7\u30b0\u30ca\u30eb\u306e\u307b\u3068\u3093\u3069\u304c\u30bf\u30fc\u30b2\u30c3\u30c8\u7531\u6765\u3067\u3042\u308b\u304b\u3069\u3046\u304b\u306f\u4e0d\u660e\u3067\u3059\u3002<\/p>\n<p><strong>\u975e\u30bf\u30fc\u30b2\u30c3\u30c8\u306e\u5897\u5e45\u306f\u8a66\u6599\u3054\u3068\u306b\u5927\u304d\u304f\u7570\u306a\u308b\u53ef\u80fd\u6027\u304c\u3042\u308b\u305f\u3081\u3001\u3059\u3079\u3066\u306eSYBR Green \u53cd\u5fdc\u306b\u95a2\u3057\u3066\u5c11\u306a\u304f\u3068\u30821\u7a2e\u985e\u306e\u7279\u7570\u6027\u8a55\u4fa1\u3092\u884c\u3046\u5fc5\u8981\u304c\u3042\u308a\u307e\u3059<\/strong>\u3002\u6700\u3082\u4e00\u822c\u7684\u306b\u306f\u3001\u89e3\u96e2\u89e3\u6790\u304c\u8a55\u4fa1\u306b\u4f7f\u7528\u3055\u308c\u3066\u3044\u307e\u3059\u3002<\/p>\n<h2>SYBR Green\u89e3\u96e2\u89e3\u6790<\/h2>\n<p><strong>SYBR Green\u89e3\u96e2\u89e3\u6790\u3067\u306f\u3001SYBR Green\u3092\u5229\u7528\u3057\u305fPCR\u5f8c\u306bPCR\u7523\u7269\u3092\u52a0\u71b1\u3057\u3066\u89e3\u96e2\u89e3\u6790\u3092\u884c\u3044\u307e\u3059<\/strong>\u3002\u89e3\u96e2\u89e3\u6790\u306f\u8ffd\u52a0\u8cbb\u7528\u304c\u5fc5\u8981\u306a\u304f\u3001PCR\u53cd\u5fdc\u30d7\u30ec\u30fc\u30c8\u3092\u76f4\u63a5\u4f7f\u7528\u3067\u304d\u308b\u305f\u3081\u3001\u7279\u7570\u6027\u8a55\u4fa1\u306b\u304a\u3044\u3066\u9b45\u529b\u3042\u308b\u9078\u629e\u80a2\u3067\u3059\u3002\u3057\u304b\u3057\u89e3\u96e2\u89e3\u6790\u306f\u3001\u30b5\u30fc\u30de\u30eb\u30d7\u30ed\u30c8\u30b3\u30eb\u6642\u9593\u3092\u5ef6\u9577\u3057\u3066\u884c\u3046\u305f\u3081\u8ffd\u52a0\u306e\u89e3\u6790\u6642\u9593\u304c\u5fc5\u8981\u3068\u306a\u308a\u3001\u4e3b\u89b3\u7684\u306a\u9762\u3082\u3042\u308a\u3001\u5206\u96e2\u80fd\u304c\u5236\u9650\u3055\u308c\u3066\u3044\u307e\u3059\u3002<\/p>\n<p>SYBR Green \u89e3\u96e2\u89e3\u6790\u306f\u3001<strong>\u30bf\u30fc\u30b2\u30c3\u30c8\u304c\u4e00\u3064\u306e\u6c7a\u307e\u3063\u305f\u907a\u4f1d\u5b50\u914d\u5217\u3067\u3042\u308b\u306a\u3089\u3070\u4e00\u3064\u306e\u7279\u5b9a\u306e\u878d\u70b9\uff08Tm\uff09\u3092\u6709\u3057\u3001\u305d\u308c\u3092\u5229\u7528\u3057\u3066\u8a66\u6599\u4e2d\u306e\u30bf\u30fc\u30b2\u30c3\u30c8\u3092\u540c\u5b9a\u3059\u308b\u3053\u3068\u304c\u53ef\u80fd\u3068\u3044\u3046\u30b3\u30f3\u30bb\u30d7\u30c8<\/strong>\u306b\u57fa\u3065\u3044\u3066\u3044\u307e\u3059\u3002\u975e\u30bf\u30fc\u30b2\u30c3\u30c8\u7523\u7269\u306e\u4e2d\u306b\u306f\u30bf\u30fc\u30b2\u30c3\u30c8\u7523\u7269\u3068\u306f\u8457\u3057\u304f\u7570\u306a\u308bTm\u3092\u6301\u3064\u3082\u306e\u304c\u3042\u308a\u3001\u305d\u306e\u3088\u3046\u306a\u975e\u30bf\u30fc\u30b2\u30c3\u30c8\u306e\u5897\u5e45\u3092\u691c\u51fa\u3059\u308b\u3053\u3068\u304c\u53ef\u80fd\u3067\u3059\u3002<\/p>\n<p>\u89e3\u96e2\u89e3\u6790\u30d7\u30ed\u30c8\u30b3\u30fc\u30eb\u306fPCR\u30b5\u30a4\u30af\u30eb\u306e\u5f8c\u306b\u4ed8\u3051\u52a0\u3048\u307e\u3059\u3002\u89e3\u96e2\u53cd\u5fdc\u304c\u7d42\u308a\u3057\u3060\u3044\u3001\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u30bd\u30d5\u30c8\u30a6\u30a7\u30a2\u304c\u30c7\u30fc\u30bf\u3092\u8ca0\u306e\u4e00\u6b21\u5c0e\u95a2\u6570\u3068\u3057\u3066\u30d7\u30ed\u30c3\u30c8\u3057\u3001\u878d\u89e3\u30d7\u30ed\u30d5\u30a1\u30a4\u30eb\u3092\u30d4\u30fc\u30af\u306b\u8ee2\u63db\u3057\u307e\u3059\u3002<\/p>\n<p><strong>\u5358\u4e00\u306e\u30bf\u30fc\u30b2\u30c3\u30c8\u5206\u5b50\u3092\u7528\u3044\u3066\u5897\u5e45\u3059\u308b\u3053\u3068\u3067\u3001\u30bf\u30fc\u30b2\u30c3\u30c8\u306e\u30d4\u30fc\u30af\u3092\u6b63\u78ba\u306b\u540c\u5b9a\u3067\u304d\u307e\u3059<\/strong>\u3002RNA\u304a\u3088\u3073\u30b2\u30ce\u30e0DNA\u306a\u3069\u306e\u591a\u304f\u306e\u8a66\u6599\u306f\u9ad8\u5ea6\u306a\u907a\u4f1d\u5b50\u8907\u96d1\u6027\u3092\u3082\u3064\u305f\u3081\u3001\u30bf\u30fc\u30b2\u30c3\u30c8\u306e\u5897\u5e45\u3092\u6291\u5236\u3057\u3001\u6642\u306b\u306f\u878d\u89e3\u30d4\u30fc\u30af\u306e\u5f62\u72b6\u3092\u5909\u5316\u3055\u305b\u308b\u53ef\u80fd\u6027\u306e\u3042\u308b\u3001\u975e\u30bf\u30fc\u30b2\u30c3\u30c8\u5897\u5e45\u304c\u8d77\u3053\u308b\u53ef\u80fd\u6027\u3092\u6709\u3057\u3066\u3044\u307e\u3059\u3002\u7d14\u7c8b\u306a\u30bf\u30fc\u30b2\u30c3\u30c8\u3092\u540c\u6642\u306b\u5897\u5e45\u3059\u308b\u3068\u3001\u5897\u5e45\u5f8c\u306bTm \u306e\u30d4\u30fc\u30af\u304a\u3088\u3073\u5f62\u72b6\u3092\u7279\u5b9a\u306e\u30bf\u30fc\u30b2\u30c3\u30c8\u3068\u95a2\u9023\u4ed8\u3051\u308b\u3053\u3068\u304c\u3067\u304d\u307e\u3059\u3002\u5358\u72ec\u306e\u30d4\u30fc\u30af\u306e\u307f\u304c\u691c\u51fa\u3055\u308c\u308b\u306e\u304c\u7406\u60f3\u7684\u3067\u3059\u3002\u30bf\u30fc\u30b2\u30c3\u30c8\u30d4\u30fc\u30af\u306f\u3001\u5e45\u304c\u72ed\u304f\u3001\u5bfe\u79f0\u7684\u3067\u3001\u80a9\u3084\u30d4\u30fc\u30af\u304c\u5272\u308c\u308b\u306a\u3069\u306e\u7570\u5e38\u304c\u89b3\u5bdf\u3055\u308c\u306a\u3044\u3053\u3068\u304c\u5fc5\u8981\u3067\u3059\u3002\u3053\u308c\u3089\u306e\u7570\u5e38\u304c\u307f\u3089\u308c\u305f\u5834\u5408\u3001\u8fd1\u4f3c\u3059\u308bTm\u3092\u6709\u3059\u308b\u8907\u6570\u306e\u7523\u7269\u304c\u5b58\u5728\u3059\u308b\u53ef\u80fd\u6027\u304c\u9ad8\u304f\u3001\u3053\u308c\u3089\u306e\u53cd\u5fdc\u306e\u7279\u7570\u6027\u304c\u5f37\u304f\u7591\u308f\u308c\u307e\u3059\u3002\u89e3\u96e2\u89e3\u6790\u3067\u7570\u5e38\u304c\u307f\u3089\u308c\u305f\u30a6\u30a7\u30eb\u306f\u89e3\u6790\u5bfe\u8c61\u5916\u306b\u3059\u308b\u5fc5\u8981\u304c\u3042\u308a\u307e\u3059\u3002<\/p>\n<p><strong>SYBR Green\u89e3\u96e2\u89e3\u6790\u306f\u5206\u96e2\u80fd\u304c\u4f4e\u304f\u3001Tm \u304c\u8fd1\u4f3c\u3059\u308b\u30bf\u30fc\u30b2\u30c3\u30c8\u3068\u975e\u30bf\u30fc\u30b2\u30c3\u30c8\u3001\u4f8b\u3048\u3070\u76f8\u540c\u914d\u5217\u3092\u8b58\u5225\u3059\u308b\u3053\u3068\u304c\u3067\u304d\u306a\u3044\u53ef\u80fd\u6027<\/strong>\u304c\u3042\u308a\u307e\u3059\u3002\u3053\u306e\u305f\u3081\u3001\u3055\u3089\u306b\u6839\u62e0\u3068\u306a\u308b\u60c5\u5831\u304c\u306a\u3044\u5834\u5408\u306b\u306f\u30011\u3064\u306e\u5e45\u306e\u72ed\u3044\u5bfe\u79f0\u7684\u306a\u30d4\u30fc\u30af\u3092\u30bf\u30fc\u30b2\u30c3\u30c8\u7531\u6765\u306e\u30d4\u30fc\u30af\u3067\u3042\u308b\u3068\u5b8c\u5168\u306b\u307f\u306a\u3059\u3053\u3068\u306f\u3067\u304d\u307e\u305b\u3093\u3002<\/p>\n<p><strong>\u89e3\u96e2\u89e3\u6790\u30c7\u30fc\u30bf\u306f\u3001\u5897\u5e45\u304c\u89b3\u5bdf\u3055\u308c\u305f\u3059\u3079\u3066\u306e\u30a6\u30a7\u30eb\u306b\u304a\u3044\u3066\u305d\u308c\u305e\u308c\u8a55\u4fa1\u3059\u308b\u5fc5\u8981\u304c\u3042\u308a\u307e\u3059<\/strong>\u3002\u8a66\u6599\u306b\u7d14\u7c8b\u306a\u30bf\u30fc\u30b2\u30c3\u30c8\u30d4\u30fc\u30af\u306b\u76f8\u5f53\u3057\u306a\u3044\u30d4\u30fc\u30af\u304c\u5b58\u5728\u3059\u308b\u5834\u5408\u306b\u306f\u3001\u305d\u306e\u53cd\u5fdc\u306b\u304a\u3044\u3066\u30bf\u30fc\u30b2\u30c3\u30c8\u306f\u691c\u51fa\u3055\u308c\u3066\u3044\u306a\u3044\u3068\u5224\u65ad\u3057\u307e\u3059\u3002\u8a66\u6599\u306b\u5358\u4e00\u306e\u30bf\u30fc\u30b2\u30c3\u30c8\u30d4\u30fc\u30af\u306eTm \u304a\u3088\u3073\u5f62\u72b6\u3068\u30de\u30c3\u30c1\u3059\u308b\u30d4\u30fc\u30af\u304c\u542b\u307e\u308c\u308b\u5834\u5408\u306b\u306f\u3001\u305d\u306e\u53cd\u5fdc\u306b\u304a\u3044\u3066\u30bf\u30fc\u30b2\u30c3\u30c8\u304c\u5897\u5e45\u3055\u308c\u305f\u53ef\u80fd\u6027\u304c\u3042\u308a\u307e\u3059\u3002\u89e3\u96e2\u89e3\u6790\u30c7\u30fc\u30bf\u306f\u3001\u305d\u308c\u306e\u307f\u3067\u306f\u6c7a\u5b9a\u7684\u8981\u7d20\u3068\u306a\u308a\u307e\u305b\u3093\u304c\u3001\u30bf\u30fc\u30b2\u30c3\u30c8\u3092\u542b\u307e\u306a\u3044\u8a66\u6599\u304b\u3089\u306e\u30c7\u30fc\u30bf\u3001\u30b7\u30fc\u30b1\u30f3\u30b7\u30f3\u30b0\u3001\u307e\u305f\u306f\u30b2\u30eb\u96fb\u6c17\u6cf3\u52d5\u306a\u3069\u4ed6\u306e\u30c7\u30fc\u30bf\u3068\u7d44\u307f\u5408\u308f\u305b\u308b\u3053\u3068\u306b\u3088\u3063\u3066\u3001\u7279\u7570\u6027\u306e\u4fe1\u983c\u5ea6\u3092\u9ad8\u3081\u308b\u3053\u3068\u304c\u3067\u304d\u307e\u3059\u3002<\/p>\n<h2>\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u88c5\u7f6e<\/h2>\n<p>\u69d8\u3005\u306a\u4ed5\u69d8\u306e\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u88c5\u7f6e\u304c\u3042\u308a\u307e\u3059\u304c\u3001\u5168\u3066\u306e\u88c5\u7f6e\u306b\u86cd\u5149\u8272\u7d20\u3092\u52b1\u8d77\u3059\u308b\u52b1\u8d77\u5149\u6e90\u304a\u3088\u3073\u86cd\u5149\u767a\u5149\u3092\u691c\u51fa\u3059\u308b\u691c\u51fa\u5668\u304a\u3088\u3073\u30b5\u30fc\u30de\u30eb\u30b5\u30a4\u30af\u30e9\u30fc\u304c\u642d\u8f09\u3055\u308c\u3066\u3044\u307e\u3059\u3002\u30b5\u30fc\u30de\u30eb\u30d6\u30ed\u30c3\u30af\u306b\u306f\u3001<a href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/life-science\/pcr\/real-time-pcr\/real-time-pcr-instruments.html?CID=gsd_pcr_sbu_r04_jp_cp0000_pjt0000_gsd00000_0so_blg_op_awa_oc_s00_qpcr44_Social_LAB\" target=\"_blank\" rel=\"noopener noreferrer\">Applied Biosystems\u2122 StepOnePlus\u2122 \u30b7\u30b9\u30c6\u30e0<\/a>\u306b\u642d\u8f09\u3055\u308c\u3066\u3044\u308b\u56fa\u5b9a\u578b\u3068\u3001<a href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/life-science\/pcr\/real-time-pcr\/real-time-pcr-instruments\/viia-7-real-time-pcr-system.html?CID=gsd_pcr_sbu_r04_jp_cp0000_pjt0000_gsd00000_0so_blg_op_awa_oc_s00_qpcr44_Social_LAB\" target=\"_blank\" rel=\"noopener noreferrer\">Applied Biosystems\u2122 ViiA\u2122 7 \u30b7\u30b9\u30c6\u30e0<\/a>\u304a\u3088\u3073<a href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/life-science\/pcr\/real-time-pcr\/real-time-pcr-instruments\/quantstudio-systems\/models\/quantstudio-12-flex.html?CID=gsd_pcr_sbu_r04_jp_cp0000_pjt0000_gsd00000_0so_blg_op_awa_oc_s00_qpcr44_Social_LAB\" target=\"_blank\" rel=\"noopener noreferrer\">AppliedBiosystems\u2122 QuantStudio\u2122 12K Flex \u30b7\u30b9\u30c6\u30e0<\/a>\u306b\u642d\u8f09\u3055\u308c\u3066\u3044\u308b\u3088\u3046\u306a\u30e6\u30fc\u30b6\u30fc\u304c\u4ea4\u63db\u53ef\u80fd\u306a\u30bf\u30a4\u30d7\u304c\u3042\u308a\u307e\u3059\u300248\u30a6\u30a7\u30eb\u30d7\u30ec\u30fc\u30c8\u300196\u30a6\u30a7\u30eb\u30d7\u30ec\u30fc\u30c8\u3001384\u30a6\u30a7\u30eb\u30d7\u30ec\u30fc\u30c8\u3001384\u30de\u30a4\u30af\u30ed\u30a6\u30a7\u30eb\u30ab\u30fc\u30c9\u30013072\u30b9\u30eb\u30fc\u30db\u30fc\u30eb\u30d7\u30ec\u30fc\u30c8\u306a\u3069\u69d8\u3005\u306aPCR\u53cd\u5fdc\u30d5\u30a9\u30fc\u30de\u30c3\u30c8\u304c\u4f7f\u7528\u3067\u304d\u308b\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u88c5\u7f6e\u3092\u3054\u63d0\u4f9b\u3057\u3066\u3044\u307e\u3059\u3002\u53c8\u3059\u3079\u3066\u306e\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u88c5\u7f6e\u306b\u306f\u30c7\u30fc\u30bf\u53ce\u96c6\u304a\u3088\u3073\u89e3\u6790\u7528\u306e\u30bd\u30d5\u30c8\u30a6\u30a7\u30a2\u304c\u642d\u8f09\u3055\u308c\u3066\u3044\u307e\u3059\u3002<\/p>\n<h2>\u8272\u7d20\u306e\u8b58\u5225<\/h2>\n<p><strong>\u901a\u5e38\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u53cd\u5fdc\u7cfb\u306b\u306f\u8907\u6570\u306e\u8272\u7d20\u304c\u542b\u307e\u308c\u3066\u3044\u307e\u3059<\/strong>\u3002\u4f8b\u3092\u6319\u3052\u308b\u3068\u30011\u3064\u53c8\u306f\u8907\u6570\u306e\u30ea\u30dd\u30fc\u30bf\u30fc\u8272\u7d20\u3001\u30af\u30a8\u30f3\u30c1\u30e3\u30fc\u8272\u7d20\u3001\u305d\u3057\u3066\u6700\u3082\u983b\u7e41\u306b\u4f7f\u7528\u3055\u308c\u308b\u30d1\u30c3\u30b7\u30d6\u30ea\u30d5\u30a1\u30ec\u30f3\u30b9\u8272\u7d20\u306a\u3069\u3067\u3059\u3002\u540c\u4e00\u30a6\u30a7\u30eb\u306b\u8907\u6570\u306e\u86cd\u5149\u304c\u5165\u3063\u3066\u3044\u308b\u5834\u5408\u3082\u3001\u52b1\u8d77\u304a\u3088\u3073\u767a\u5149\u30d5\u30a3\u30eb\u30bf\u30fc\u306e\u6700\u9069\u306a\u7d44\u307f\u5408\u308f\u305b\u304a\u3088\u3073\u30de\u30eb\u30c1\u30b3\u30f3\u30dd\u30fc\u30cd\u30f3\u30c8\u88dc\u6b63\u306b\u3088\u308a\u3001\u500b\u5225\u306b\u6e2c\u5b9a\u3059\u308b\u3053\u3068\u304c\u53ef\u80fd\u3067\u3059\u3002<\/p>\n<p><strong>\u30de\u30eb\u30c1\u30b3\u30f3\u30dd\u30fc\u30cd\u30f3\u30c8\u88dc\u6b63\u306f\u53cd\u5fdc\u4e2d\u306e\u5404\u8272\u7d20\u306e\u86cd\u5149\u5f37\u5ea6\u3092\u6e2c\u5b9a\u3059\u308b\u624b\u6cd5\u3067\u3059<\/strong>\u3002\u30de\u30eb\u30c1\u30b3\u30f3\u30dd\u30fc\u30cd\u30f3\u30c6\u30a3\u30f3\u30b0\u306f\u3001\u691c\u51fa\u3055\u308c\u305f\u86cd\u5149\u30b7\u30b0\u30ca\u30eb\u306e\u69cb\u6210\u8981\u7d20\u3092\u5206\u96e2\u3001\u533a\u5225\u3059\u308b\u30a2\u30eb\u30b4\u30ea\u30ba\u30e0\u3067\u3059\u3002\u3053\u306e\u30b7\u30b9\u30c6\u30e0\u3092\u7528\u3044\u305f\u30bd\u30d5\u30c8\u30a6\u30a8\u30a2\u306b\u3088\u308a\u3001\u86cd\u5149\u8272\u7d20\u306e\u30b7\u30b0\u30ca\u30eb\u3092\u6b63\u78ba\u306b\u89e3\u6790\u3057\u3001\u8907\u6570\u306e\u86cd\u5149\u8272\u7d20\u306e\u540c\u6642\u691c\u51fa\u304c\u53ef\u80fd\u306b\u306a\u308a\u3001\u53c8\u3001\u30c8\u30e9\u30d6\u30eb\u30b7\u30e5\u30fc\u30c6\u30a3\u30f3\u30b0\u306b\u6709\u7528\u306a\u60c5\u5831\u3082\u5f97\u3089\u308c\u307e\u3059\u3002<\/p>\n<h2>\u3010\u7121\u6599\u30c0\u30a6\u30f3\u30ed\u30fc\u30c9\u3011\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u30cf\u30f3\u30c9\u30d6\u30c3\u30af<\/h2>\n<p>\u3053\u306e\u30cf\u30f3\u30c9\u30d6\u30c3\u30af\u3067\u306f\u3001\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u306e\u7406\u8ad6\u3084\u5b9f\u9a13\u30c7\u30b6\u30a4\u30f3\u306e\u8a2d\u8a08\u306a\u3069\u3001\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u306e\u57fa\u790e\u77e5\u8b58\u304c\u63b2\u8f09\u3055\u308c\u3066\u3044\u307e\u3059\u3002\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u3092\u59cb\u3081\u305f\u3070\u304b\u308a\u306e\u65b9\u3084\u3053\u308c\u304b\u3089\u5b9f\u9a13\u3092\u8003\u3048\u3066\u3044\u308b\u65b9\u306b\u3046\u3063\u3066\u3064\u3051\u306e\u30cf\u30f3\u30c9\u30d6\u30c3\u30af\u3067\u3059\u3002PDF\u30d5\u30a1\u30a4\u30eb\u306e\u30c0\u30a6\u30f3\u30ed\u30fc\u30c9\u3092\u3054\u5e0c\u671b\u306e\u65b9\u306f\u3001\u4e0b\u8a18\u30dc\u30bf\u30f3\u3088\u308a\u304a\u7533\u3057\u8fbc\u307f\u304f\u3060\u3055\u3044\u3002<\/p>\n<p><a class=\"btn btn-red\" href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/global\/forms\/real-time-pcr-handbook-form.html?CID=gsd_pcr_sbu_r04_jp_cp0000_pjt0000_gsd00000_0so_blg_op_awa_oc_s00_qpcr44_Social_LAB\" target=\"_blank\" rel=\"noopener\">\u30c0\u30a6\u30f3\u30ed\u30fc\u30c9\u3059\u308b<\/a><\/p>\n<p>&nbsp;<\/p>\n<h2>\u3010\u7121\u6599\u516c\u958b\u4e2d\u3011\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u30c8\u30e9\u30d6\u30eb\u30b7\u30e5\u30fc\u30c6\u30a3\u30f3\u30b0<\/h2>\n<p>\u7570\u5e38\u306aS\u5b57\u72b6\u306e\u5897\u5e45\u66f2\u7dda\u3001NTC\u3067\u306e\u5897\u5e45\u691c\u51fa\u3001\u5897\u5e45\u304c\u898b\u3089\u308c\u306a\u3044\u306a\u3069\u3001\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u306e\u5b9f\u9a13\u4e2d\u306b\u56f0\u3063\u305f\u969b\u306e\u624b\u52a9\u3051\u306b\u306a\u308b\u60c5\u5831\u3092\u7d39\u4ecb\u3057\u3066\u3044\u307e\u3059\u3002PDF\u30d5\u30a1\u30a4\u30eb\u306e\u30c0\u30a6\u30f3\u30ed\u30fc\u30c9\u3092\u3054\u5e0c\u671b\u306e\u65b9\u306f\u3001\u4e0b\u8a18\u30dc\u30bf\u30f3\u3088\u308a\u304a\u7533\u3057\u8fbc\u307f\u304f\u3060\u3055\u3044\u3002<\/p>\n<p><a class=\"btn btn-red\" href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/global\/forms\/pcr-system-troubleshooting.html?CID=gsd_pcr_sbu_r04_jp_cp0000_pjt0000_gsd00000_0so_blg_op_awa_oc_s00_qpcr44_Social_LAB\" target=\"_blank\" rel=\"noopener\">\u30c0\u30a6\u30f3\u30ed\u30fc\u30c9\u3059\u308b<\/a><\/p>\n<p>&nbsp;<\/p>\n<p>\u7814\u7a76\u7528\u306b\u306e\u307f\u4f7f\u7528\u3067\u304d\u307e\u3059\u3002\u8a3a\u65ad\u7528\u306b\u306f\u4f7f\u7528\u3044\u305f\u3060\u3051\u307e\u305b\u3093\u3002<\/p>\n","protected":false},"excerpt":{"rendered":"<p>\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u306b\u306f\u3001\u591a\u304f\u306e\u86cd\u5149\u30b1\u30df\u30b9\u30c8\u30ea\u304c\u5b58\u5728\u3057\u307e\u3059\u3002\u4eca\u56de\u306f\u3001Taqman Assay\u3084SYBR Green\u8272\u7d20\u30d9\u30fc\u30b9\u306e\u30a2\u30c3\u30bb\u30a4\u306a\u3069\u3001\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u306b\u304a\u3051\u308b\u86cd\u5149\u691c\u51fa\u30b7\u30b9\u30c6\u30e0\u306b\u3064\u3044\u3066\u3054\u7d39\u4ecb\u3057\u307e\u3059\u3002<\/p>\n","protected":false},"author":988,"featured_media":3155,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_monsterinsights_skip_tracking":false,"_genesis_hide_title":false,"_genesis_hide_breadcrumbs":false,"_genesis_hide_singular_image":false,"_genesis_hide_footer_widgets":false,"_genesis_custom_body_class":"","_genesis_custom_post_class":"","_genesis_layout":"","_jetpack_newsletter_access":"","_jetpack_dont_email_post_to_subs":false,"_jetpack_newsletter_tier_id":0,"_jetpack_memberships_contains_paywalled_content":false,"_jetpack_feature_clip_id":0,"_jetpack_memberships_contains_paid_content":false,"footnotes":"","jetpack_post_was_ever_published":false},"categories":[156],"tags":[7],"division":[],"class_list":["post-656","post","type-post","status-publish","format-standard","has-post-thumbnail","category-mol-bio","tag-qpcr","entry"],"_selected_authors":"","_selected_reviewers":"","acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v27.8 (Yoast SEO v27.8) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>\u3042\u306a\u305f\u306fTaqMan\uff1f\u305d\u308c\u3068\u3082SYBR Green\uff1f\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u306b\u304a\u3051\u308b\u86cd\u5149\u691c\u51fa\u30b7\u30b9\u30c6\u30e0\u306e\u539f\u7406 - Learning at the Bench<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/qpcr-basic38\/\" \/>\n<meta property=\"og:locale\" content=\"ja_JP\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"\u3042\u306a\u305f\u306fTaqMan\uff1f\u305d\u308c\u3068\u3082SYBR Green\uff1f\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u306b\u304a\u3051\u308b\u86cd\u5149\u691c\u51fa\u30b7\u30b9\u30c6\u30e0\u306e\u539f\u7406\" \/>\n<meta property=\"og:description\" content=\"\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u306b\u306f\u3001\u591a\u304f\u306e\u86cd\u5149\u30b1\u30df\u30b9\u30c8\u30ea\u304c\u5b58\u5728\u3057\u307e\u3059\u3002\u4eca\u56de\u306f\u3001Taqman Assay\u3084SYBR Green\u8272\u7d20\u30d9\u30fc\u30b9\u306e\u30a2\u30c3\u30bb\u30a4\u306a\u3069\u3001\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u306b\u304a\u3051\u308b\u86cd\u5149\u691c\u51fa\u30b7\u30b9\u30c6\u30e0\u306b\u3064\u3044\u3066\u3054\u7d39\u4ecb\u3057\u307e\u3059\u3002\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/qpcr-basic38\/\" \/>\n<meta property=\"og:site_name\" content=\"Learning at the Bench\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/ThermoFisherJapan\" \/>\n<meta property=\"article:published_time\" content=\"2017-03-02T00:00:00+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2025-04-16T06:25:26+00:00\" \/>\n<meta property=\"og:image\" content=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/qpcr-basic38-title.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"1200\" \/>\n\t<meta property=\"og:image:height\" content=\"628\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"LATB Staff\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:creator\" content=\"@ThermoFisherJP\" \/>\n<meta name=\"twitter:site\" content=\"@ThermoFisherJP\" \/>\n<meta name=\"twitter:label1\" content=\"\u57f7\u7b46\u8005\" \/>\n\t<meta name=\"twitter:data1\" content=\"LATB Staff\" \/>\n\t<meta name=\"twitter:label2\" content=\"\u63a8\u5b9a\u8aad\u307f\u53d6\u308a\u6642\u9593\" \/>\n\t<meta name=\"twitter:data2\" content=\"21\u5206\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/qpcr-basic38\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/qpcr-basic38\\\/\"},\"author\":{\"name\":\"LATB Staff\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#\\\/schema\\\/person\\\/201e6a5abb838fa34e8ff0174b015d36\"},\"headline\":\"\u3042\u306a\u305f\u306fTaqMan\uff1f\u305d\u308c\u3068\u3082SYBR Green\uff1f\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u306b\u304a\u3051\u308b\u86cd\u5149\u691c\u51fa\u30b7\u30b9\u30c6\u30e0\u306e\u539f\u7406\",\"datePublished\":\"2017-03-02T00:00:00+00:00\",\"dateModified\":\"2025-04-16T06:25:26+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/qpcr-basic38\\\/\"},\"wordCount\":229,\"commentCount\":0,\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/qpcr-basic38\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2019\\\/07\\\/qpcr-basic38-title.jpg\",\"keywords\":[\"\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\"],\"articleSection\":[\"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023\"],\"inLanguage\":\"ja\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/qpcr-basic38\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/qpcr-basic38\\\/\",\"url\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/qpcr-basic38\\\/\",\"name\":\"\u3042\u306a\u305f\u306fTaqMan\uff1f\u305d\u308c\u3068\u3082SYBR Green\uff1f\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u306b\u304a\u3051\u308b\u86cd\u5149\u691c\u51fa\u30b7\u30b9\u30c6\u30e0\u306e\u539f\u7406 - Learning at the Bench\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/qpcr-basic38\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/qpcr-basic38\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2019\\\/07\\\/qpcr-basic38-title.jpg\",\"datePublished\":\"2017-03-02T00:00:00+00:00\",\"dateModified\":\"2025-04-16T06:25:26+00:00\",\"author\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#\\\/schema\\\/person\\\/201e6a5abb838fa34e8ff0174b015d36\"},\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/qpcr-basic38\\\/#breadcrumb\"},\"inLanguage\":\"ja\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/qpcr-basic38\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"ja\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/qpcr-basic38\\\/#primaryimage\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2019\\\/07\\\/qpcr-basic38-title.jpg\",\"contentUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2019\\\/07\\\/qpcr-basic38-title.jpg\",\"width\":1200,\"height\":628,\"caption\":\"qpcr-basic38-title\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/qpcr-basic38\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"\u3042\u306a\u305f\u306fTaqMan\uff1f\u305d\u308c\u3068\u3082SYBR Green\uff1f\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u306b\u304a\u3051\u308b\u86cd\u5149\u691c\u51fa\u30b7\u30b9\u30c6\u30e0\u306e\u539f\u7406\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#website\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/\",\"name\":\"Learning at the Bench\",\"description\":\"\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"ja\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#\\\/schema\\\/person\\\/201e6a5abb838fa34e8ff0174b015d36\",\"name\":\"LATB Staff\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"ja\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/8803277856c8b753feb4217dff0f9953327452df1a615c3c88b2f9864efb2ddd?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/8803277856c8b753feb4217dff0f9953327452df1a615c3c88b2f9864efb2ddd?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/8803277856c8b753feb4217dff0f9953327452df1a615c3c88b2f9864efb2ddd?s=96&d=mm&r=g\",\"caption\":\"LATB Staff\"},\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/author\\\/latbstaff\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"\u3042\u306a\u305f\u306fTaqMan\uff1f\u305d\u308c\u3068\u3082SYBR Green\uff1f\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u306b\u304a\u3051\u308b\u86cd\u5149\u691c\u51fa\u30b7\u30b9\u30c6\u30e0\u306e\u539f\u7406 - Learning at the Bench","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/qpcr-basic38\/","og_locale":"ja_JP","og_type":"article","og_title":"\u3042\u306a\u305f\u306fTaqMan\uff1f\u305d\u308c\u3068\u3082SYBR Green\uff1f\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u306b\u304a\u3051\u308b\u86cd\u5149\u691c\u51fa\u30b7\u30b9\u30c6\u30e0\u306e\u539f\u7406","og_description":"\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u306b\u306f\u3001\u591a\u304f\u306e\u86cd\u5149\u30b1\u30df\u30b9\u30c8\u30ea\u304c\u5b58\u5728\u3057\u307e\u3059\u3002\u4eca\u56de\u306f\u3001Taqman Assay\u3084SYBR Green\u8272\u7d20\u30d9\u30fc\u30b9\u306e\u30a2\u30c3\u30bb\u30a4\u306a\u3069\u3001\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u306b\u304a\u3051\u308b\u86cd\u5149\u691c\u51fa\u30b7\u30b9\u30c6\u30e0\u306b\u3064\u3044\u3066\u3054\u7d39\u4ecb\u3057\u307e\u3059\u3002","og_url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/qpcr-basic38\/","og_site_name":"Learning at the Bench","article_publisher":"https:\/\/www.facebook.com\/ThermoFisherJapan","article_published_time":"2017-03-02T00:00:00+00:00","article_modified_time":"2025-04-16T06:25:26+00:00","og_image":[{"width":1200,"height":628,"url":"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/qpcr-basic38-title.jpg","type":"image\/jpeg"}],"author":"LATB Staff","twitter_card":"summary_large_image","twitter_creator":"@ThermoFisherJP","twitter_site":"@ThermoFisherJP","twitter_misc":{"\u57f7\u7b46\u8005":"LATB Staff","\u63a8\u5b9a\u8aad\u307f\u53d6\u308a\u6642\u9593":"21\u5206"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/qpcr-basic38\/#article","isPartOf":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/qpcr-basic38\/"},"author":{"name":"LATB Staff","@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#\/schema\/person\/201e6a5abb838fa34e8ff0174b015d36"},"headline":"\u3042\u306a\u305f\u306fTaqMan\uff1f\u305d\u308c\u3068\u3082SYBR Green\uff1f\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u306b\u304a\u3051\u308b\u86cd\u5149\u691c\u51fa\u30b7\u30b9\u30c6\u30e0\u306e\u539f\u7406","datePublished":"2017-03-02T00:00:00+00:00","dateModified":"2025-04-16T06:25:26+00:00","mainEntityOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/qpcr-basic38\/"},"wordCount":229,"commentCount":0,"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/qpcr-basic38\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/qpcr-basic38-title.jpg","keywords":["\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR"],"articleSection":["\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023"],"inLanguage":"ja","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/qpcr-basic38\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/qpcr-basic38\/","url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/qpcr-basic38\/","name":"\u3042\u306a\u305f\u306fTaqMan\uff1f\u305d\u308c\u3068\u3082SYBR Green\uff1f\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u306b\u304a\u3051\u308b\u86cd\u5149\u691c\u51fa\u30b7\u30b9\u30c6\u30e0\u306e\u539f\u7406 - Learning at the Bench","isPartOf":{"@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/qpcr-basic38\/#primaryimage"},"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/qpcr-basic38\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/qpcr-basic38-title.jpg","datePublished":"2017-03-02T00:00:00+00:00","dateModified":"2025-04-16T06:25:26+00:00","author":{"@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#\/schema\/person\/201e6a5abb838fa34e8ff0174b015d36"},"breadcrumb":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/qpcr-basic38\/#breadcrumb"},"inLanguage":"ja","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/qpcr-basic38\/"]}]},{"@type":"ImageObject","inLanguage":"ja","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/qpcr-basic38\/#primaryimage","url":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/qpcr-basic38-title.jpg","contentUrl":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/qpcr-basic38-title.jpg","width":1200,"height":628,"caption":"qpcr-basic38-title"},{"@type":"BreadcrumbList","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/qpcr-basic38\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/"},{"@type":"ListItem","position":2,"name":"\u3042\u306a\u305f\u306fTaqMan\uff1f\u305d\u308c\u3068\u3082SYBR Green\uff1f\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u306b\u304a\u3051\u308b\u86cd\u5149\u691c\u51fa\u30b7\u30b9\u30c6\u30e0\u306e\u539f\u7406"}]},{"@type":"WebSite","@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#website","url":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/","name":"Learning at the Bench","description":"","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"ja"},{"@type":"Person","@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#\/schema\/person\/201e6a5abb838fa34e8ff0174b015d36","name":"LATB Staff","image":{"@type":"ImageObject","inLanguage":"ja","@id":"https:\/\/secure.gravatar.com\/avatar\/8803277856c8b753feb4217dff0f9953327452df1a615c3c88b2f9864efb2ddd?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/8803277856c8b753feb4217dff0f9953327452df1a615c3c88b2f9864efb2ddd?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/8803277856c8b753feb4217dff0f9953327452df1a615c3c88b2f9864efb2ddd?s=96&d=mm&r=g","caption":"LATB Staff"},"url":"https:\/\/admin.acceleratingscience.com\/author\/latbstaff\/"}]}},"taxonomy_info":{"category":[{"value":156,"label":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023"}],"post_tag":[{"value":7,"label":"\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR"}]},"featured_image_src_large":["https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/qpcr-basic38-title-1024x536.jpg",760,398,true],"author_info":{"display_name":"LATB Staff","author_link":"https:\/\/admin.acceleratingscience.com\/author\/latbstaff\/"},"comment_info":0,"category_info":[{"term_id":156,"name":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","slug":"mol-bio","term_group":0,"term_taxonomy_id":156,"taxonomy":"category","description":"","parent":0,"count":540,"filter":"raw","meta":[],"cat_ID":156,"category_count":540,"category_description":"","cat_name":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","category_nicename":"mol-bio","category_parent":0}],"tag_info":[{"term_id":7,"name":"\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR","slug":"qpcr","term_group":0,"term_taxonomy_id":7,"taxonomy":"post_tag","description":"","parent":0,"count":91,"filter":"raw","meta":[]}],"jetpack-related-posts":[{"id":25325,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/exosome-gene-expression-ts-r-25019\/","url_meta":{"origin":656,"position":0},"title":"\u3010\u7b2c5\u56de\u3011 &#8220;RNA cargo&#8221;\u306e\u7cbe\u88fd\u3068\u5b9a\u91cf\u89e3\u6790\u300d\uff5emRNA\u306e\u5b9a\u91cf\u89e3\u6790\uff5e","author":"LatB Staff","date":"2026\u5e746\u670811\u65e5","format":false,"excerpt":"\u4eca\u56de\u306f\u3001\u30a8\u30af\u30bd\u30bd\u30fc\u30e0\uff08\u30a8\u30ad\u30bd\u30bd\u30fc\u30e0\uff09\u4e2d\u306emRNA\u306e\u5b9a\u91cf\u89e3\u6790\u306b\u3064\u3044\u3066\u8aac\u660e\u3057\u307e\u3059\u3002\u7b2c3\u56de\u3067\u30a8\u30af\u30bd\u30bd\u30fc\u30e0\u304b\u2026","rel":"","context":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","block_context":{"text":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/mol-bio\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25018_eyecatch-1.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25018_eyecatch-1.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25018_eyecatch-1.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25018_eyecatch-1.jpg?resize=700%2C400&ssl=1 2x"},"classes":[]},{"id":25247,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/exosome-gene-expression-ts-r-25018\/","url_meta":{"origin":656,"position":1},"title":"\u3010\u7b2c4\u56de\u3011&#8221;RNA cargo&#8221;\u306e\u7cbe\u88fd\u3068\u5b9a\u91cf\u89e3\u6790\uff5emiRNA\u306e\u5b9a\u91cf\u89e3\u6790\uff5e","author":"LatB Staff","date":"2026\u5e745\u670829\u65e5","format":false,"excerpt":"\u524d\u56de\uff08\u3010\u7b2c3\u56de\u3011\u201cRNA cargo\u201d\u306e\u7cbe\u88fd\u3068\u5b9a\u91cf\u89e3\u6790\uff09\u3067\u306f\u3001\u30a8\u30af\u30bd\u30bd\u30fc\u30e0 \uff08\u30a8\u30ad\u30bd\u30bd\u30fc\u30e0\uff09 \u304b\u3089\u306e\u2026","rel":"","context":"\u5206\u6790\u30fb\u6e2c\u5b9a\u95a2\u9023","block_context":{"text":"\u5206\u6790\u30fb\u6e2c\u5b9a\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/analysis\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25018_eyecatch-1.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25018_eyecatch-1.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25018_eyecatch-1.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25018_eyecatch-1.jpg?resize=700%2C400&ssl=1 2x"},"classes":[]},{"id":24416,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/cell-imaging-fluorescent-dye-bid-ts-mbr-25076\/","url_meta":{"origin":656,"position":2},"title":"Cell Painting Assay\u3067\u7528\u3044\u3089\u308c\u308b\u8a66\u85ac\u306b\u3064\u3044\u3066\uff08MitoTracker\u3092\u7528\u3044\u305f\u30df\u30c8\u30b3\u30f3\u30c9\u30ea\u30a2\u67d3\u8272\uff09","author":"LatB Staff","date":"2025\u5e7412\u670819\u65e5","format":false,"excerpt":"\u8fd1\u5e74\u3001\u30bb\u30eb\u30da\u30a4\u30f3\u30c6\u30a3\u30f3\u30b0\uff08Cell Painting\uff09\u3068\u3044\u3046\u30a2\u30c3\u30bb\u30a4\u65b9\u6cd5\u304c\u5e83\u307e\u308a\u3064\u3064\u3042\u308a\u307e\u3059\u3002\u4f8b\u3048\u3070\u2026","rel":"","context":"\u7d30\u80de\u57f9\u990a\u30fb\u30a4\u30e1\u30fc\u30b8\u30f3\u30b0","block_context":{"text":"\u7d30\u80de\u57f9\u990a\u30fb\u30a4\u30e1\u30fc\u30b8\u30f3\u30b0","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/cell\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/12\/cell-imaging-fluorescent-dye-bid-ts-mbr-25076_eyecatch-scaled.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/12\/cell-imaging-fluorescent-dye-bid-ts-mbr-25076_eyecatch-scaled.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/12\/cell-imaging-fluorescent-dye-bid-ts-mbr-25076_eyecatch-scaled.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/12\/cell-imaging-fluorescent-dye-bid-ts-mbr-25076_eyecatch-scaled.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/12\/cell-imaging-fluorescent-dye-bid-ts-mbr-25076_eyecatch-scaled.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/12\/cell-imaging-fluorescent-dye-bid-ts-mbr-25076_eyecatch-scaled.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":24545,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/digital-pcr-gene-expression-gsd-ts-sd-25082\/","url_meta":{"origin":656,"position":3},"title":"\u3010Absolute Q\u30c7\u30b8\u30bf\u30ebPCR\u30b7\u30b9\u30c6\u30e0\u306e\u6d3b\u7528\u4f8b\u3011\u30df\u30c8\u30b3\u30f3\u30c9\u30ea\u30a2DNA\u306e\u5b9a\u91cf","author":"LatB Staff","date":"2026\u5e741\u670816\u65e5","format":false,"excerpt":"Applied Biosystems\u2122 QuantStudio\u2122 Absolute Q\u2122 \u30c7\u30b8\u30bf\u30ebP\u2026","rel":"","context":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","block_context":{"text":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/mol-bio\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/12\/digital-pcr-gene-expression-gsd-ts-sd-25082_eyecatch.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/12\/digital-pcr-gene-expression-gsd-ts-sd-25082_eyecatch.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/12\/digital-pcr-gene-expression-gsd-ts-sd-25082_eyecatch.jpg?resize=525%2C300&ssl=1 1.5x"},"classes":[]},{"id":25565,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/exosome-antibody-ts-r-25068\/","url_meta":{"origin":656,"position":4},"title":"\u3010\u7b2c8\u56de\u3011\u30a8\u30af\u30bd\u30bd\u30fc\u30e0\u30b5\u30d6\u30bf\u30a4\u30d7\u306e\u5206\u753b\u6cd5 \uff1a \u30a6\u30a7\u30b9\u30bf\u30f3\u30d6\u30ed\u30c3\u30c8\uff0fqRT-PCR\uff0f\u30b7\u30fc\u30b1\u30f3\u30b9\u89e3\u6790\u306b\u9069\u3057\u305f\u5206\u753b\u65b9\u6cd5","author":"LatB Staff","date":"2026\u5e749\u670829\u65e5","format":false,"excerpt":"\u672c\u7a3f\u3067\u306f\u3001\u30a8\u30af\u30bd\u30bd\u30fc\u30e0\u819c\u4e0a\u306e\u7279\u5b9a\u306e\u30bf\u30f3\u30d1\u30af\u8cea\u3092\u6a19\u7684\u3068\u3057\u305f\u514d\u75ab\u5438\u7740\u6cd5\u306b\u57fa\u3065\u304f\u5206\u753b\u624b\u6cd5\u3092\u7d39\u4ecb\u3057\u307e\u3059\u3002\u30a8\u30af\u2026","rel":"","context":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","block_context":{"text":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/mol-bio\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25019_eyecatch.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25019_eyecatch.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25019_eyecatch.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25019_eyecatch.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25019_eyecatch.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25019_eyecatch.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":24382,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/cell-imaging-fluorescent-dye-bid-ts-mbr-25075\/","url_meta":{"origin":656,"position":5},"title":"Cell Painting Assay\u3067\u7528\u3044\u3089\u308c\u308b\u8a66\u85ac\u306b\u3064\u3044\u3066 (Hoechst\u3092\u7528\u3044\u305f\u6838\u67d3\u8272\uff09","author":"LatB Staff","date":"2025\u5e7412\u670810\u65e5","format":false,"excerpt":"\u8fd1\u5e74\u3001\u30bb\u30eb\u30da\u30a4\u30f3\u30c6\u30a3\u30f3\u30b0\uff08Cell Painting\uff09\u3068\u3044\u3046\u30a2\u30c3\u30bb\u30a4\u65b9\u6cd5\u304c\u5e83\u307e\u308a\u3064\u3064\u3042\u308a\u307e\u3059\u3002\u7d30\u80de\u306b\u2026","rel":"","context":"\u7d30\u80de\u57f9\u990a\u30fb\u30a4\u30e1\u30fc\u30b8\u30f3\u30b0","block_context":{"text":"\u7d30\u80de\u57f9\u990a\u30fb\u30a4\u30e1\u30fc\u30b8\u30f3\u30b0","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/cell\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/11\/cell-imaging-fluorescent-dye-bid-ts-mbr-25075_eyecatch-scaled.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/11\/cell-imaging-fluorescent-dye-bid-ts-mbr-25075_eyecatch-scaled.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/11\/cell-imaging-fluorescent-dye-bid-ts-mbr-25075_eyecatch-scaled.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/11\/cell-imaging-fluorescent-dye-bid-ts-mbr-25075_eyecatch-scaled.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/11\/cell-imaging-fluorescent-dye-bid-ts-mbr-25075_eyecatch-scaled.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/11\/cell-imaging-fluorescent-dye-bid-ts-mbr-25075_eyecatch-scaled.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]}],"jetpack_sharing_enabled":true,"amp_enabled":true,"jetpack_featured_media_url":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/qpcr-basic38-title.jpg","_links":{"self":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/posts\/656","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/users\/988"}],"replies":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/comments?post=656"}],"version-history":[{"count":0,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/posts\/656\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/media\/3155"}],"wp:attachment":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/media?parent=656"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/categories?post=656"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/tags?post=656"},{"taxonomy":"division","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/division?post=656"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}