{"id":6567,"date":"2020-05-19T11:28:55","date_gmt":"2020-05-19T02:28:55","guid":{"rendered":"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/?p=6567"},"modified":"2021-12-01T17:02:12","modified_gmt":"2021-12-01T08:02:12","slug":"agrigenomics_ma_gsd_ts_1","status":"publish","type":"post","link":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/agrigenomics_ma_gsd_ts_1\/","title":{"rendered":"\u8089\u725b\u304a\u3088\u3073\u4e73\u725b\u306e\u4fa1\u5024\u3068\u53ce\u76ca\u6027\u6539\u5584\u306e\u305f\u3081\u306e\u907a\u4f1d\u5b50\u691c\u67fb"},"content":{"rendered":"<h2>\u306f\u3058\u3081\u306b<\/h2>\n<p>\u6628\u4eca\u3001\u907a\u4f1d\u5b50\u691c\u67fb\u6280\u8853\u306f\u6025\u901f\u306b\u9032\u6b69\u3057\u3066\u3044\u307e\u3059\u3002\u30b5\u30fc\u30e2\u30d5\u30a3\u30c3\u30b7\u30e3\u30fc\u30b5\u30a4\u30a8\u30f3\u30c6\u30a3\u30d5\u30a3\u30c3\u30af\u306e<a href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/life-science\/agricultural-biotechnology\/agrigenomics.html?CID=Gsd_agr_anh_r04_jp_cp1355_pjt5725_gsd00000_0so_blg_op_lgn_kt_s00_ma2_Social_LAB\" target=\"_blank\" rel=\"noopener noreferrer\">\u30a2\u30b0\u30ea\u30b2\u30ce\u30df\u30af\u30b9\u306e\u30dd\u30fc\u30c8\u30d5\u30a9\u30ea\u30aa<\/a>\u306b\u3042\u308b\u3001Applied Biosystems\u2122 AgriSeq\u2122 \u30bf\u30fc\u30b2\u30c3\u30c8\u30bd\u30ea\u30e5\u30fc\u30b7\u30e7\u30f3\u306a\u3069\u306e\u30c4\u30fc\u30eb\u306f\u3001\u30cf\u30a4\u30b9\u30eb\u30fc\u30d7\u30c3\u30c8\u3067\u6b63\u78ba\u306a\u30c7\u30fc\u30bf\u304c\u5f97\u3089\u308c\u3001\u30b2\u30ce\u30e0\u80b2\u7a2e\u306b\u304a\u3051\u308b\u610f\u601d\u6c7a\u5b9a\u3092\u4fc3\u9032\u3057\u307e\u3059\u3002\u80b2\u7a2e\u5bb6\u3084\u751f\u7523\u8005\u306f\u3001\u7279\u5b9a\u306e\u7fa4\u306e\u30cb\u30fc\u30ba\u306b\u7126\u70b9\u3092\u5f53\u3066\u3001\u5bb6\u755c\u306e\u4fa1\u5024\u3068\u53ce\u76ca\u6027\u3092\u6539\u5584\u3059\u308b\u305f\u3081\u306e\u7d4c\u6e08\u7684\u95a2\u9023\u5f62\u8cea(economically relevant traits, ERT)\u3092\u9078\u629e\u3059\u308b\u3053\u3068\u3067\u3001\u3053\u308c\u3089\u306e\u907a\u4f1d\u5b50\u691c\u67fb\u306e\u6280\u8853\u7684\u9032\u6b69\u3092\u5229\u7528\u3067\u304d\u307e\u3059\u3002<br \/>\n\u30b2\u30ce\u30e0\u80b2\u7a2e\u30d7\u30ed\u30b0\u30e9\u30e0\u3067\u306f\u3001\u52d5\u7269\u306e\u4fa1\u5024\u3092\u898b\u3064\u3051\u51fa\u3059\u305f\u3081\u306b\u3055\u307e\u3056\u307e\u306a\u30a2\u30d7\u30ed\u30fc\u30c1\u304c\u7528\u3044\u3089\u308c\u3066\u3044\u307e\u3059\u3002\u3044\u305a\u308c\u3082\u3001\u7279\u5b9a\u306e\u5f62\u8cea\u307e\u305f\u306f\u8868\u73fe\u578b\u3092\u4e88\u6e2c\u307e\u305f\u306f\u95a2\u9023\u4ed8\u3051\u308b\u5206\u5b50\u30de\u30fc\u30ab\u30fc\u3092\u540c\u5b9a\u3059\u308b\u3053\u3068\u3092\u983c\u308a\u306b\u3057\u3066\u3044\u307e\u3059\u3002SNP(\u4e00\u5869\u57fa\u591a\u578b)\u691c\u51fa\u3092\u7528\u3044\u308b\u691c\u67fb\u306f\u3001\u6bdb\u306e\u8272\u3001\u7b4b\u8089\u80a5\u5927\u3001\u75be\u60a3\u306a\u3069\u306e\u72b6\u614b\u306b\u95a2\u9023\u3059\u308b\u907a\u4f1d\u7684\u5909\u7570\u3092\u540c\u5b9a\u3059\u308b\u3082\u306e\u3067\u3001\u691c\u67fb\u30b9\u30d4\u30fc\u30c9\u304c\u901f\u3044\u305f\u3081\u3001\u307e\u3059\u307e\u3059\u666e\u53ca\u3057\u3066\u3044\u307e\u3059\u3002\u4e00\u56de\u306e\u30b7\u30fc\u30b1\u30f3\u30b7\u30f3\u30b0\u3067\u3001\u6570\u767e\u30b5\u30f3\u30d7\u30eb\u3001\u6570\u5343 SNP \u3092\u51e6\u7406\u3057\u3001\u6570\u65e5\u4ee5\u5185\u306b\u7d50\u679c\u3092\u5f97\u308b\u3053\u3068\u304c\u53ef\u80fd\u3067\u3059\u3002<\/p>\n<h2>\u907a\u4f1d\u5b50\u691c\u67fb\u304c\u725b\u306e\u7e41\u6b96\u306b\u6709\u7528\u306a\u4e09\u3064\u306e\u4e3b\u306a\u9818\u57df\uff1a<\/h2>\n<p>\u3053\u308c\u3089\u4e09\u3064\u306e\u9818\u57df\u306b\u3064\u3044\u3066\u4ee5\u4e0b\u3067\u8aac\u660e\u3057\u307e\u3059\uff1a<br \/>\n1. \u9ad8\u4fa1\u5024\u306a\u751f\u7523\u5f62\u8cea\u306e\u305f\u3081\u306e\u907a\u4f1d\u7684\u9078\u629e<br \/>\n2. \u6d88\u8cbb\u8005\u306e\u597d\u307f\u3084\u75c5\u6c17\u306e\u56de\u907f\u306e\u305f\u3081\u306e\u8868\u73fe\u578b\u306e\u9078\u629e<br \/>\n3. \u52d5\u7269\u500b\u4f53\u306e\u540c\u5b9a\u304a\u3088\u3073\u7fa4\u306e\u7ba1\u7406\u306e\u305f\u3081\u306e\u89aa\u5b50\u9451\u5b9a<\/p>\n<h3>\u907a\u4f1d\u7684\u9078\u629e<\/h3>\n<p>\u907a\u4f1d\u7684\u9078\u629e\u306f\u3001\u7d4c\u6e08\u7684\u95a2\u9023\u5f62\u8cea(ERT)\u3092\u540c\u5b9a\u3059\u308b\u3053\u3068\u3001\u304a\u3088\u3073\u3001\u7e41\u6b96\u80fd\u529b\u3068\u751f\u7523\u306e\u4e21\u65b9\u306b\u3064\u3044\u3066\u52d5\u7269\u306e\u4fa1\u5024\u306e\u5411\u4e0a\u304c\u671f\u5f85\u3055\u308c\u308b\u5b50\u5b6b\u306e\u5dee\u7570\u306b\u4f9d\u5b58\u3057\u3066\u3044\u307e\u3059\u3002\u4f8b\u3048\u3070\u3001\u4e73\u725b\u306e\u7fa4\u306e\u7a2e\u96c4\u725b\u3092\u9078\u629c\u3059\u308b\u969b\u306b\u3001\u96cc\u306e\u4ed4\u725b\u306e\u7523\u4e73\u91cf\u3068\u3044\u3063\u305f\u4fa1\u5024\u5f62\u8cea\u306b\u96c6\u4e2d\u3059\u308b\u3053\u3068\u304c\u3067\u304d\u307e\u3059\u3002\u7a2e\u96c4\u725b\u306e\u9670\u56a2\u5468\u56f2\u9577\u304c\u3088\u308a\u5927\u304d\u3044\u3053\u3068\u306e\u5206\u5b50\u30de\u30fc\u30ab\u30fc\u306f\u3001\u96cc\u306e\u4ed4\u725b\u304c\u3088\u308a\u65e9\u671f\u306b\u601d\u6625\u671f\u3092\u8fce\u3048\u308b\u3053\u3068\u3092\u4e88\u6e2c\u3057\u307e\u3059\u3002\u725b\u8089\u306e\u751f\u7523\u3067\u306f\u3001\u6210\u719f\u91cd\u91cf\u3084\u3001\u3088\u308a\u9ad8\u52b9\u7387\u306a\u98fc\u6599\u8981\u6c42\u7387\u7b49\u306e\u5f62\u8cea\u304c\u671b\u307e\u308c\u307e\u3059\u3002<br \/>\n\u907a\u4f1d\u7684\u9078\u629e\u30c4\u30fc\u30eb\u3092\u8ce2\u304f\u4f7f\u7528\u3059\u308b\u3053\u3068\u3067\u3001\u725b\u7fa4\u306e\u53ce\u76ca\u6027\u3092\u9ad8\u3081\u308b\u3053\u3068\u304c\u3067\u304d\u307e\u3059\u3002\u4f8b\u3048\u3070\u3001\u4e73\u91cf\u3001\u96e2\u4e73\u6642\u306e\u4f53\u91cd\u3001\u8089\u306e\u7279\u6027\u304c\u512a\u308c\u3066\u3044\u308b\u500b\u4f53\u3092\u7279\u5b9a\u3067\u304d\u308c\u3070\u3001\u3088\u308a\u512a\u308c\u305f\u755c\u7523\u7269\u3092\u5e02\u5834\u306b\u9001\u308a\u51fa\u305b\u307e\u3059\u3002<br \/>\n\u3057\u304b\u3057\u3001\u725b\u7fa4\u3092\u6539\u826f\u3055\u305b\u308b\u305f\u3081\u306b\u306f\u3001\u751f\u7523\u8005\u306f\u30b3\u30b9\u30c8\u3092\u5897\u52a0\u3055\u305b\u308b\u306e\u3067\u306f\u306a\u304f\u3001\u53ce\u76ca\u6027\u3092\u6539\u5584\u3059\u308b\u5f62\u8cea\u3092\u9078\u629e\u3059\u308b\u3088\u3046\u306b\u6ce8\u610f\u3057\u306a\u3051\u308c\u3070\u306a\u308a\u307e\u305b\u3093\u3002\u4f8b\u3048\u3070\u3001\u6025\u901f\u306a\u6210\u9577\u3084\u9ad8\u4e73\u91cf\u3092\u9078\u629e\u3057\u305f\u3068\u3057\u3066\u3082\u3001\u6804\u990a\u3084\u98fc\u6599\u306e\u8cea\u304c\u5236\u9650\u8981\u56e0\u3068\u306a\u3063\u3066\u3044\u308c\u3070\u751f\u7523\u3092\u6700\u9069\u5316\u3067\u304d\u307e\u305b\u3093\u3002\u74b0\u5883\u4e0a\u3084\u755c\u7523\u4e0a\u306e\u5236\u7d04\u306e\u4e2d\u3067\u725b\u7fa4\u306e\u907a\u4f1d\u7684\u9078\u629e\u3092\u8a55\u4fa1\u3059\u308b\u3053\u3068\u3067\u3001\u725b\u7fa4\u306e\u5229\u76ca\u3092\u6700\u5927\u5316\u3057\u3001\u80fd\u529b\u3092\u6700\u5927\u9650\u306b\u767a\u63ee\u3055\u305b\u308b\u3053\u3068\u304c\u3067\u304d\u307e\u3059\u3002<\/p>\n<h3>\u8868\u73fe\u578b\u306e\u9078\u629e\u306e\u305f\u3081\u306e\u5f62\u8cea\u691c\u67fb<\/h3>\n<p>\u7279\u5b9a\u306e\u8868\u73fe\u578b\u3068\u95a2\u9023\u3059\u308b\u5206\u5b50\u30de\u30fc\u30ab\u30fc\u306f\u3001\u751f\u7523\u54c1\u8cea(\u971c\u964d\u308a\u8089)\u3001\u5916\u898b\u7684\u7279\u5fb4(\u6d88\u8cbb\u8005\u597d\u307f\u306e\u8d64\u6bdb\u307e\u305f\u306f\u9ed2\u6bdb)\u3001\u75be\u60a3\u611f\u53d7\u6027(\u30a2\u30f3\u30ac\u30b9\u725b\u306e\u03b1-\u30de\u30f3\u30ce\u30b7\u30c0\u30fc\u30bc\u6b20\u640d\u75c7\u306a\u3069\u9175\u7d20\u6b20\u640d\u75c7)\u306e\u4e88\u6e2c\u306b\u6709\u7528\u3067\u3059\u3002<br \/>\n\u52a3\u6027\u3067\u907a\u4f1d\u3059\u308b\u8868\u73fe\u578b\u3082\u3042\u308a\u3001\u80b2\u7a2e\u5bb6\u306f\u30d8\u30c6\u30ed\u63a5\u5408\u4f53\u306e\u500b\u4f53\u3092\u96c6\u56e3\u5185\u3042\u308b\u3044\u306f\u80b2\u7a2e\u74b0\u5883\u5185\u306e\u4fdd\u56e0\u8005\u3068\u3057\u3066\u540c\u5b9a\u3059\u308b\u3053\u3068\u304c\u91cd\u8981\u3067\u3059\u3002\u3053\u308c\u3089\u306b\u306f\u3001\u6bdb\u8272\u306a\u3069\u306e\u5916\u898b\u7684\u7279\u5fb4\u3001\u75be\u60a3\u3084\u5909\u5f62\u3092\u5f15\u304d\u8d77\u3053\u3059\u6709\u5bb3\u306a\u7a81\u7136\u5909\u7570\u304c\u542b\u307e\u308c\u307e\u3059\u3002<br \/>\n\u3042\u308b\u7a2e\u306e\u98fc\u80b2\u30b7\u30b9\u30c6\u30e0\u3067\u306f\u3001\u5916\u898b\u7684\u7279\u5fb4\u304c\u5f71\u97ff\u3092\u53ca\u307c\u3059\u3053\u3068\u304c\u3042\u308a\u307e\u3059\u3002\u4f8b\u3048\u3070\u3001\u30a2\u30eb\u30d3\u30ce\u306e\u725b\u3067\u306f\u5149\u7dda\u904e\u654f\u75c7\u304c\u5897\u52a0\u3057\u3001\u982d\u90e8\u304c\u767d\u8272\u306e\u725b\u3067\u306f\u773c\u306e\u5468\u56f2\u306e\u304c\u3093\u306a\u3069\u76ae\u819a\u75be\u60a3\u306e\u30ea\u30b9\u30af\u3082\u5897\u5927\u3057\u307e\u3059\u3002\u30d8\u30ec\u30d5\u30a9\u30fc\u30c9\u3084\u540c\u696d\u306e\u30d6\u30ea\u30fc\u30c0\u30fc\u306f\u3001\u300c\u30b4\u30fc\u30b0\u30eb\u300d(\u76ee\u306e\u5468\u308a\u306e\u6bdb\u3068\u8272\u7d20\u304c\u6fc3\u3044\u72b6\u614b) \u3092\u6301\u3064\u500b\u4f53\u3092\u9078\u629e\u3059\u308b\u3053\u3068\u304c\u3042\u308a\u307e\u3059\u304c\u3001\u3053\u306e\u8868\u73fe\u578b\u306e\u907a\u4f1d\u306f\u5b8c\u5168\u306b\u306f\u89e3\u660e\u3055\u308c\u3066\u306f\u3044\u307e\u305b\u3093\u3002<br \/>\n\u5916\u898b\u7684\u306a\u8868\u73fe\u578b\u306e\u3044\u304f\u3064\u304b\u306e\u30de\u30fc\u30ab\u30fc\u3082\u6f5c\u5728\u7684\u306a\u5947\u5f62\u306b\u5bfe\u3059\u308b\u3088\u3044\u6307\u6a19\u3067\u3059\u3002\u305f\u3068\u3048\u3070\u3001\u30d9\u30eb\u30ae\u30a2\u30f3\u30fb\u30d6\u30eb\u30fc\u3084\u30b7\u30e7\u30fc\u30c8\u30db\u30fc\u30f3\u7a2e\u306e\u767d\u6bdb\u304c\u96cc\u725b\u306e\u751f\u6b96\u5668\u5b98\u306e\u767a\u80b2\u4e0d\u5168\u3068\u95a2\u9023\u304c\u3042\u308b\u30db\u30ef\u30a4\u30c8\u30d8\u30a4\u30d5\u30a1\u30fc\u75c5\u306f\u305d\u306e\u4e00\u4f8b\u3067\u3059\u3002\u7f79\u60a3\u52d5\u7269\u306f\u901a\u5e38\u4e0d\u598a\u3068\u306a\u308a\u307e\u3059\u3002\u3053\u308c\u306f\u5916\u9762\u7684\u306b\u306f\u660e\u767d\u3067\u306f\u306a\u304f\u4e00\u90e8\u306e\u725b\u7fa4\u7ba1\u7406\u30b7\u30b9\u30c6\u30e0\u3067\u306f\u5bb9\u6613\u306b\u767a\u898b\u3067\u304d\u306a\u3044\u305f\u3081\u3001\u725b\u7fa4\u5168\u4f53\u306e\u4f4e\u53d7\u80ce\u3092\u5f15\u304d\u8d77\u3053\u3059\u539f\u56e0\u3068\u306a\u308a\u3048\u307e\u3059\u3002<\/p>\n<h3>\u89aa\u5b50\u9451\u5b9a<\/h3>\n<p>\u89aa\u5b50\u9451\u5b9a\u306f\u3001\u30b7\u30f3\u30d7\u30eb\u306a\u907a\u4f1d\u306b\u57fa\u3065\u3044\u3066\u500b\u4f53\u3092\u9664\u5916\u3059\u308b\u3053\u3068\u3092\u76ee\u7684\u306b\u3001SNP\u3084\u4ed6\u306e\u5206\u5b50\u30de\u30fc\u30ab\u30fc\u3092\u7528\u3044\u308b\u30b2\u30ce\u30e0\u8a55\u4fa1\u3092\u983c\u308a\u306b\u3057\u3066\u3044\u307e\u3059\u3002<br \/>\n\u7ba1\u7406\u72b6\u6cc1\u306b\u3088\u3063\u3066\u306f\u3001\u89aa\u5b50\u95a2\u4fc2\u304c\u3059\u3050\u306b\u306f\u5206\u304b\u3089\u306a\u3044\u5834\u5408\u3082\u3042\u308a\u307e\u3059\u3002<br \/>\n\u3059\u3079\u3066\u306e\u53ef\u80fd\u6027\u306e\u3042\u308b\u89aa\u725b\u306b\u5bfe\u3059\u308b\u4ed4\u725b\u306e\u907a\u4f1d\u5b66\u7684\u8a55\u4fa1\u306b\u3088\u3063\u3066\u3001\u7279\u5b9a\u306e\u7fa4\u7ba1\u7406\u30b7\u30b9\u30c6\u30e0\u4e0b\u3067\u4ed4\u725b\u304c\u4eba\u5de5\u6388\u7cbe\u307e\u305f\u306f\u81ea\u7136\u5206\u5a29\u306e\u7d50\u679c\u3067\u3042\u308b\u304b\u3069\u3046\u304b\u3092\u78ba\u8a8d\u3059\u308b\u3053\u3068\u304c\u3067\u304d\u307e\u3059\u3002\u3053\u308c\u306f\u307e\u305f\u3001\u8907\u6570\u306e\u96c4\u725b\u304c\u7fa4\u308c\u3068\u5171\u306b\u81ea\u7531\u306b\u884c\u52d5\u3059\u308b\u72b6\u6cc1\u306b\u304a\u3044\u3066\u3001\u751f\u7523\u8005\u304c\u76e3\u8996\u3057\u306a\u3044\u5834\u5408\u306b\u3082\u6709\u7528\u306a\u30c4\u30fc\u30eb\u3067\u3059\u3002<br \/>\n\u907a\u4f1d\u5b50\u691c\u67fb\u306f\u3001\u500b\u4f53\u306e\u8eab\u5143\u3092\u78ba\u8a8d\u3059\u308b\u305f\u3081\u306b\u3082\u3001\u8ca9\u58f2\u524d\u304a\u3088\u3073\u8ca9\u58f2\u5f8c\u306b\u6709\u76ca\u306a\u500b\u4f53\u306e\u5bb6\u7cfb\u56f3\u3092\u4f5c\u6210\u3059\u308b\u969b\u306b\u3082\u6709\u7528\u3067\u3059\u3002\u307e\u305f\u3001\u751f\u7523\u8005\u304c\u80da\u79fb\u690d\u306e\u5b50\u5b6b\u3092\u78ba\u8a8d\u3059\u308b\u305f\u3081\u306b\u3082\u4f7f\u7528\u3067\u304d\u307e\u3059\u3002<\/p>\n<h2>\u307e\u3068\u3081<\/h2>\n<p>\u3053\u308c\u3089\u306e\u30c4\u30fc\u30eb\u304c\u7e41\u6b96\u30d7\u30ed\u30b0\u30e9\u30e0\u306b\u3069\u306e\u3088\u3046\u306b\u5f79\u7acb\u3064\u304b\u77e5\u308a\u305f\u3044\u5834\u5408\u306f\u3001\u5f0a\u793e\u307e\u3067\u76f8\u8ac7\u304f\u3060\u3055\u3044\u3002\u307e\u305f\u3001\u30b5\u30fc\u30e2\u30d5\u30a3\u30c3\u30b7\u30e3\u30fc\u30b5\u30a4\u30a8\u30f3\u30c6\u30a3\u30d5\u30a3\u30c3\u30af\u306e\u30b2\u30ce\u30e0\u80b2\u7a2e\u30d7\u30ed\u30b0\u30e9\u30e0\u306e\u30bd\u30ea\u30e5\u30fc\u30b7\u30e7\u30f3\u3082\u3054\u89a7\u3044\u305f\u3060\u3051\u308c\u3070\u3068\u601d\u3044\u307e\u3059\u3002<\/p>\n<p><a href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/products-and-services\/services\/technical-services\/inquiry.html?CID=Gsd_agr_anh_r04_jp_cp1355_pjt5725_gsd00000_0so_blg_op_lgn_kt_s00_ma2_Social_LAB\" target=\"_blank\" rel=\"noopener noreferrer\">\u6280\u8853\u30b5\u30fc\u30d3\u30b9\u306b\u95a2\u3059\u308b\u304a\u554f\u3044\u5408\u308f\u305b<\/a><\/p>\n<p><a href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/life-science\/microarray-analysis\/agrigenomics-solutions-microarrays-gbs.html?CID=Gsd_agr_anh_r04_jp_cp1355_pjt5725_gsd00000_0so_blg_op_lgn_kt_s00_ma2_Social_LAB\" target=\"_blank\" rel=\"noopener noreferrer\">\u30de\u30a4\u30af\u30ed\u30a2\u30ec\u30a4\u3068 GBS \u3092\u7528\u3044\u305f\u30a2\u30b0\u30ea\u30b2\u30ce\u30df\u30af\u30b9\u30bd\u30ea\u30e5\u30fc\u30b7\u30e7\u30f3<\/a><\/p>\n<p><a href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/life-science\/microarray-analysis\/agrigenomics-solutions-microarrays-gbs\/axiom-genotyping-solution-agrigenomics.html?CID=Gsd_agr_anh_r04_jp_cp1355_pjt5725_gsd00000_0so_blg_op_lgn_kt_s00_ma2_Social_LAB\" target=\"_blank\" rel=\"noopener noreferrer\">\u30a2\u30b0\u30ea\u30b2\u30ce\u30df\u30af\u30b9\u7528 Axiom Genotyping Solution<\/a><\/p>\n<p>Further Reading<br \/>\nBeef cattle genomics at <a href=\"http:\/\/ebeef.org\/\" target=\"_blank\" rel=\"noopener noreferrer\">http:\/\/ebeef.org\/<\/a><\/p>\n<p>&nbsp;<\/p>\n<p>\u7814\u7a76\u7528\u306b\u306e\u307f\u4f7f\u7528\u3067\u304d\u307e\u3059\u3002\u8a3a\u65ad\u7528\u306b\u306f\u4f7f\u7528\u3044\u305f\u3060\u3051\u307e\u305b\u3093\u3002<\/p>\n","protected":false},"excerpt":{"rendered":"<p>\u306f\u3058\u3081\u306b \u6628\u4eca\u3001\u907a\u4f1d\u5b50\u691c\u67fb\u6280\u8853\u306f\u6025\u901f\u306b\u9032\u6b69\u3057\u3066\u3044\u307e\u3059\u3002\u30b5\u30fc\u30e2\u30d5\u30a3\u30c3\u30b7\u30e3\u30fc\u30b5\u30a4\u30a8\u30f3\u30c6\u30a3\u30d5\u30a3\u30c3\u30af\u306e\u30a2\u30b0\u30ea\u30b2\u30ce\u30df\u30af\u30b9\u306e\u30dd\u30fc\u30c8\u30d5\u30a9\u30ea\u30aa\u306b\u3042\u308b\u3001Applied Biosystems\u2122 AgriSeq\u2122 \u30bf\u30fc\u30b2\u30c3\u30c8\u30bd\u30ea\u30e5\u30fc\u30b7\u30e7\u30f3\u306a\u3069<\/p>\n","protected":false},"author":975,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_monsterinsights_skip_tracking":false,"_genesis_hide_title":false,"_genesis_hide_breadcrumbs":false,"_genesis_hide_singular_image":false,"_genesis_hide_footer_widgets":false,"_genesis_custom_body_class":"","_genesis_custom_post_class":"","_genesis_layout":"","_jetpack_newsletter_access":"","_jetpack_dont_email_post_to_subs":false,"_jetpack_newsletter_tier_id":0,"_jetpack_memberships_contains_paywalled_content":false,"_jetpack_feature_clip_id":0,"_jetpack_memberships_contains_paid_content":false,"footnotes":"","jetpack_post_was_ever_published":false},"categories":[156],"tags":[],"division":[],"class_list":{"0":"post-6567","1":"post","2":"type-post","3":"status-publish","4":"format-standard","6":"category-mol-bio","7":"entry"},"_selected_authors":"","_selected_reviewers":"","acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v27.8 (Yoast SEO v27.8) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>\u8089\u725b\u304a\u3088\u3073\u4e73\u725b\u306e\u4fa1\u5024\u3068\u53ce\u76ca\u6027\u6539\u5584\u306e\u305f\u3081\u306e\u907a\u4f1d\u5b50\u691c\u67fb - Learning at the Bench<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/agrigenomics_ma_gsd_ts_1\/\" \/>\n<meta property=\"og:locale\" content=\"ja_JP\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"\u8089\u725b\u304a\u3088\u3073\u4e73\u725b\u306e\u4fa1\u5024\u3068\u53ce\u76ca\u6027\u6539\u5584\u306e\u305f\u3081\u306e\u907a\u4f1d\u5b50\u691c\u67fb\" \/>\n<meta property=\"og:description\" content=\"\u306f\u3058\u3081\u306b \u6628\u4eca\u3001\u907a\u4f1d\u5b50\u691c\u67fb\u6280\u8853\u306f\u6025\u901f\u306b\u9032\u6b69\u3057\u3066\u3044\u307e\u3059\u3002\u30b5\u30fc\u30e2\u30d5\u30a3\u30c3\u30b7\u30e3\u30fc\u30b5\u30a4\u30a8\u30f3\u30c6\u30a3\u30d5\u30a3\u30c3\u30af\u306e\u30a2\u30b0\u30ea\u30b2\u30ce\u30df\u30af\u30b9\u306e\u30dd\u30fc\u30c8\u30d5\u30a9\u30ea\u30aa\u306b\u3042\u308b\u3001Applied Biosystems\u2122 AgriSeq\u2122 \u30bf\u30fc\u30b2\u30c3\u30c8\u30bd\u30ea\u30e5\u30fc\u30b7\u30e7\u30f3\u306a\u3069\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/agrigenomics_ma_gsd_ts_1\/\" \/>\n<meta property=\"og:site_name\" content=\"Learning at the Bench\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/ThermoFisherJapan\" \/>\n<meta property=\"article:published_time\" content=\"2020-05-19T02:28:55+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2021-12-01T08:02:12+00:00\" \/>\n<meta name=\"author\" content=\"LatB Staff\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:creator\" content=\"@ThermoFisherJP\" \/>\n<meta name=\"twitter:site\" content=\"@ThermoFisherJP\" \/>\n<meta name=\"twitter:label1\" content=\"\u57f7\u7b46\u8005\" \/>\n\t<meta name=\"twitter:data1\" content=\"LatB Staff\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/agrigenomics_ma_gsd_ts_1\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/agrigenomics_ma_gsd_ts_1\\\/\"},\"author\":{\"name\":\"LatB Staff\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#\\\/schema\\\/person\\\/bdbe319a2001f279ddce6ab8eaad1253\"},\"headline\":\"\u8089\u725b\u304a\u3088\u3073\u4e73\u725b\u306e\u4fa1\u5024\u3068\u53ce\u76ca\u6027\u6539\u5584\u306e\u305f\u3081\u306e\u907a\u4f1d\u5b50\u691c\u67fb\",\"datePublished\":\"2020-05-19T02:28:55+00:00\",\"dateModified\":\"2021-12-01T08:02:12+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/agrigenomics_ma_gsd_ts_1\\\/\"},\"wordCount\":26,\"commentCount\":0,\"articleSection\":[\"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023\"],\"inLanguage\":\"ja\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/agrigenomics_ma_gsd_ts_1\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/agrigenomics_ma_gsd_ts_1\\\/\",\"url\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/agrigenomics_ma_gsd_ts_1\\\/\",\"name\":\"\u8089\u725b\u304a\u3088\u3073\u4e73\u725b\u306e\u4fa1\u5024\u3068\u53ce\u76ca\u6027\u6539\u5584\u306e\u305f\u3081\u306e\u907a\u4f1d\u5b50\u691c\u67fb - Learning at the Bench\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#website\"},\"datePublished\":\"2020-05-19T02:28:55+00:00\",\"dateModified\":\"2021-12-01T08:02:12+00:00\",\"author\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#\\\/schema\\\/person\\\/bdbe319a2001f279ddce6ab8eaad1253\"},\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/agrigenomics_ma_gsd_ts_1\\\/#breadcrumb\"},\"inLanguage\":\"ja\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/agrigenomics_ma_gsd_ts_1\\\/\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/agrigenomics_ma_gsd_ts_1\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"\u8089\u725b\u304a\u3088\u3073\u4e73\u725b\u306e\u4fa1\u5024\u3068\u53ce\u76ca\u6027\u6539\u5584\u306e\u305f\u3081\u306e\u907a\u4f1d\u5b50\u691c\u67fb\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#website\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/\",\"name\":\"Learning at the Bench\",\"description\":\"\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"ja\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#\\\/schema\\\/person\\\/bdbe319a2001f279ddce6ab8eaad1253\",\"name\":\"LatB Staff\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"ja\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g\",\"caption\":\"LatB Staff\"},\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/author\\\/lgbadmin\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"\u8089\u725b\u304a\u3088\u3073\u4e73\u725b\u306e\u4fa1\u5024\u3068\u53ce\u76ca\u6027\u6539\u5584\u306e\u305f\u3081\u306e\u907a\u4f1d\u5b50\u691c\u67fb - Learning at the Bench","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/agrigenomics_ma_gsd_ts_1\/","og_locale":"ja_JP","og_type":"article","og_title":"\u8089\u725b\u304a\u3088\u3073\u4e73\u725b\u306e\u4fa1\u5024\u3068\u53ce\u76ca\u6027\u6539\u5584\u306e\u305f\u3081\u306e\u907a\u4f1d\u5b50\u691c\u67fb","og_description":"\u306f\u3058\u3081\u306b \u6628\u4eca\u3001\u907a\u4f1d\u5b50\u691c\u67fb\u6280\u8853\u306f\u6025\u901f\u306b\u9032\u6b69\u3057\u3066\u3044\u307e\u3059\u3002\u30b5\u30fc\u30e2\u30d5\u30a3\u30c3\u30b7\u30e3\u30fc\u30b5\u30a4\u30a8\u30f3\u30c6\u30a3\u30d5\u30a3\u30c3\u30af\u306e\u30a2\u30b0\u30ea\u30b2\u30ce\u30df\u30af\u30b9\u306e\u30dd\u30fc\u30c8\u30d5\u30a9\u30ea\u30aa\u306b\u3042\u308b\u3001Applied Biosystems\u2122 AgriSeq\u2122 \u30bf\u30fc\u30b2\u30c3\u30c8\u30bd\u30ea\u30e5\u30fc\u30b7\u30e7\u30f3\u306a\u3069","og_url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/agrigenomics_ma_gsd_ts_1\/","og_site_name":"Learning at the Bench","article_publisher":"https:\/\/www.facebook.com\/ThermoFisherJapan","article_published_time":"2020-05-19T02:28:55+00:00","article_modified_time":"2021-12-01T08:02:12+00:00","author":"LatB Staff","twitter_card":"summary_large_image","twitter_creator":"@ThermoFisherJP","twitter_site":"@ThermoFisherJP","twitter_misc":{"\u57f7\u7b46\u8005":"LatB Staff"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/agrigenomics_ma_gsd_ts_1\/#article","isPartOf":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/agrigenomics_ma_gsd_ts_1\/"},"author":{"name":"LatB Staff","@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#\/schema\/person\/bdbe319a2001f279ddce6ab8eaad1253"},"headline":"\u8089\u725b\u304a\u3088\u3073\u4e73\u725b\u306e\u4fa1\u5024\u3068\u53ce\u76ca\u6027\u6539\u5584\u306e\u305f\u3081\u306e\u907a\u4f1d\u5b50\u691c\u67fb","datePublished":"2020-05-19T02:28:55+00:00","dateModified":"2021-12-01T08:02:12+00:00","mainEntityOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/agrigenomics_ma_gsd_ts_1\/"},"wordCount":26,"commentCount":0,"articleSection":["\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023"],"inLanguage":"ja","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/agrigenomics_ma_gsd_ts_1\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/agrigenomics_ma_gsd_ts_1\/","url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/agrigenomics_ma_gsd_ts_1\/","name":"\u8089\u725b\u304a\u3088\u3073\u4e73\u725b\u306e\u4fa1\u5024\u3068\u53ce\u76ca\u6027\u6539\u5584\u306e\u305f\u3081\u306e\u907a\u4f1d\u5b50\u691c\u67fb - Learning at the Bench","isPartOf":{"@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#website"},"datePublished":"2020-05-19T02:28:55+00:00","dateModified":"2021-12-01T08:02:12+00:00","author":{"@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#\/schema\/person\/bdbe319a2001f279ddce6ab8eaad1253"},"breadcrumb":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/agrigenomics_ma_gsd_ts_1\/#breadcrumb"},"inLanguage":"ja","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/agrigenomics_ma_gsd_ts_1\/"]}]},{"@type":"BreadcrumbList","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/agrigenomics_ma_gsd_ts_1\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/"},{"@type":"ListItem","position":2,"name":"\u8089\u725b\u304a\u3088\u3073\u4e73\u725b\u306e\u4fa1\u5024\u3068\u53ce\u76ca\u6027\u6539\u5584\u306e\u305f\u3081\u306e\u907a\u4f1d\u5b50\u691c\u67fb"}]},{"@type":"WebSite","@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#website","url":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/","name":"Learning at the Bench","description":"","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"ja"},{"@type":"Person","@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#\/schema\/person\/bdbe319a2001f279ddce6ab8eaad1253","name":"LatB Staff","image":{"@type":"ImageObject","inLanguage":"ja","@id":"https:\/\/secure.gravatar.com\/avatar\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g","caption":"LatB Staff"},"url":"https:\/\/admin.acceleratingscience.com\/author\/lgbadmin\/"}]}},"taxonomy_info":{"category":[{"value":156,"label":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023"}]},"featured_image_src_large":false,"author_info":{"display_name":"LatB Staff","author_link":"https:\/\/admin.acceleratingscience.com\/author\/lgbadmin\/"},"comment_info":0,"category_info":[{"term_id":156,"name":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","slug":"mol-bio","term_group":0,"term_taxonomy_id":156,"taxonomy":"category","description":"","parent":0,"count":538,"filter":"raw","meta":[],"cat_ID":156,"category_count":538,"category_description":"","cat_name":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","category_nicename":"mol-bio","category_parent":0}],"tag_info":false,"jetpack-related-posts":[{"id":23864,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/protein-expression-cloning-bid-ts-mbr-25070\/","url_meta":{"origin":6567,"position":0},"title":"\u521d\u5fc3\u8005\u3067\u3082\u5b89\u5fc3\uff01\u7c21\u5358\u306b\u3067\u304d\u308b\u767a\u73fe\u30d9\u30af\u30bf\u30fc\u306e\u4f5c\u308a\u65b9\uff1a\u4eba\u5de5\u907a\u4f1d\u5b50\u5408\u6210\u30b5\u30fc\u30d3\u30b9\u306e\u5229\u7528\u6cd5","author":"LatB Staff","date":"2025\u5e7411\u670813\u65e5","format":false,"excerpt":"\u30bf\u30f3\u30d1\u30af\u8cea\u767a\u73fe\u5b9f\u9a13\u306b\u306f\u767a\u73fe\u30d9\u30af\u30bf\u30fc\u304c\u6b20\u304b\u305b\u307e\u305b\u3093\u304c\u3001\u4e00\u304b\u3089\u4f5c\u308b\u3068\u306a\u308b\u3068\u3001\u304b\u306a\u308a\u306e\u624b\u9593\u3068\u7d4c\u9a13\u304c\u5fc5\u8981\u3067\u3059\u2026","rel":"","context":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","block_context":{"text":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/mol-bio\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/10\/protein-expression-cloning-bid-ts-mbr-25070_eyecatch.png?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/10\/protein-expression-cloning-bid-ts-mbr-25070_eyecatch.png?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/10\/protein-expression-cloning-bid-ts-mbr-25070_eyecatch.png?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/10\/protein-expression-cloning-bid-ts-mbr-25070_eyecatch.png?resize=700%2C400&ssl=1 2x"},"classes":[]},{"id":24122,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/gene-therapy-purification-affinity-chromatography-bpg-25072\/","url_meta":{"origin":6567,"position":1},"title":"\u3010\u7c21\u5358\u89e3\u8aac\uff01\u3011\u907a\u4f1d\u5b50\u6cbb\u7642\u306b\u304a\u3051\u308b\u7cbe\u88fd\u30b9\u30b1\u30fc\u30eb\u30a2\u30c3\u30d7\u306e\u30dd\u30a4\u30f3\u30c8","author":"LatB Staff","date":"2025\u5e7411\u670826\u65e5","format":false,"excerpt":"\u8fd1\u5e74\u3001\u907a\u4f1d\u5b50\u6cbb\u7642\u306e\u6025\u901f\u306a\u767a\u5c55\u306b\u3088\u308a\u3001\u6cbb\u7642\u6cd5\u306e\u958b\u767a\u3068\u5b9f\u7528\u5316\u306b\u5411\u3051\u305f\u53d6\u308a\u7d44\u307f\u304c\u6d3b\u767a\u5316\u3057\u3066\u3044\u307e\u3059\u3002 \u672c\u30d6\u30ed\u2026","rel":"","context":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","block_context":{"text":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/mol-bio\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/11\/ngs-gene-expression-bpg-25072_eycatch.png?resize=350%2C200&ssl=1","width":350,"height":200},"classes":[]},{"id":25362,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/battery-development-ion-chromatography-csm-26020\/","url_meta":{"origin":6567,"position":2},"title":"IC-MS\/MS\u3092\u7528\u3044\u305f\u30ea\u30c1\u30a6\u30e0\u30a4\u30aa\u30f3\u96fb\u6c60\u8ca0\u6975\u306e\u52a3\u5316\u89e3\u6790","author":"LatB Staff","date":"2026\u5e746\u670826\u65e5","format":false,"excerpt":"\u539f\u6587\uff08\u82f1\u8a9e\uff09\uff1aExploring Lithium-Ion Battery Anode Degrada\u2026","rel":"","context":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","block_context":{"text":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/mol-bio\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/06\/battery-development-ion-chromatography-csm-26020_eyecatch.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/06\/battery-development-ion-chromatography-csm-26020_eyecatch.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/06\/battery-development-ion-chromatography-csm-26020_eyecatch.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/06\/battery-development-ion-chromatography-csm-26020_eyecatch.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/06\/battery-development-ion-chromatography-csm-26020_eyecatch.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/06\/battery-development-ion-chromatography-csm-26020_eyecatch.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":23239,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/ngs-gene-expression-csd-ts-bfx-25060\/","url_meta":{"origin":6567,"position":3},"title":"\u98df\u54c1\u958b\u767a\u306b\u304a\u3051\u308b\u83cc\u53e2\u89e3\u6790\u3068\u907a\u4f1d\u5b50\u767a\u73fe\u89e3\u6790\u306e\u6d3b\u7528","author":"LatB Staff","date":"2025\u5e7410\u67088\u65e5","format":false,"excerpt":"\u907a\u4f1d\u5b50\u95a2\u9023\u306e\u89e3\u6790\u6280\u8853\u304c\u7814\u7a76\u306e\u307f\u306a\u3089\u305a\u7523\u696d\u5206\u91ce\u3067\u6d3b\u7528\u3055\u308c\u308b\u3088\u3046\u306b\u306a\u308a\u3001\u5e74\u6708\u304c\u7d4c\u904e\u3059\u308b\u306b\u3064\u308c\u3066\u5fdc\u7528\u7bc4\u56f2\u3082\u2026","rel":"","context":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","block_context":{"text":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/mol-bio\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/09\/ngs-gene-expression-gsd-ts-tr-25060_eyecatch.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/09\/ngs-gene-expression-gsd-ts-tr-25060_eyecatch.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/09\/ngs-gene-expression-gsd-ts-tr-25060_eyecatch.jpg?resize=525%2C300&ssl=1 1.5x"},"classes":[]},{"id":25090,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/battery-development-elemental-analysis-csm-26016\/","url_meta":{"origin":6567,"position":4},"title":"\u30ea\u30c1\u30a6\u30e0\u30a4\u30aa\u30f3\u96fb\u6c60\u88fd\u9020\uff1a\u4f7f\u7528\u3055\u308c\u308b\u5316\u5b66\u5206\u6790\u6280\u8853","author":"LatB Staff","date":"2026\u5e744\u670820\u65e5","format":false,"excerpt":"\u9ad8\u6027\u80fd\u96fb\u6c60\u306b\u5bfe\u3059\u308b\u9700\u8981\u306e\u6025\u5897\u306f\u3001\u751f\u7523\u306e\u3042\u3089\u3086\u308b\u6bb5\u968e\u306b\u304a\u3051\u308b\u5927\u898f\u6a21\u306a\u6295\u8cc7\u3092\u4fc3\u3057\u3066\u3044\u307e\u3059\u3002\u96fb\u6c60\u7814\u7a76\u304a\u3088\u3073\u2026","rel":"","context":"\u5206\u6790\u30fb\u6e2c\u5b9a\u95a2\u9023","block_context":{"text":"\u5206\u6790\u30fb\u6e2c\u5b9a\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/analysis\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/04\/battery-development-elemental-analysis-csm-26016_eyecatch.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/04\/battery-development-elemental-analysis-csm-26016_eyecatch.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/04\/battery-development-elemental-analysis-csm-26016_eyecatch.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/04\/battery-development-elemental-analysis-csm-26016_eyecatch.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/04\/battery-development-elemental-analysis-csm-26016_eyecatch.jpg?resize=1050%2C600&ssl=1 3x"},"classes":[]},{"id":23457,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/cell-culture-cell-culture-basic-bid-ts-mbr-25063\/","url_meta":{"origin":6567,"position":5},"title":"\u7d30\u80de\u57f9\u990a\u7528\u306e\u8840\u6e05\uff08FBS\uff09\u3068\u6297\u751f\u7269\u8cea\u306e\u30dd\u30a4\u30f3\u30c8\uff5e\u7d30\u80de\u57f9\u990a\u306e\u5b8c\u5168\u30b5\u30dd\u30fc\u30c8\u30ac\u30a4\u30c9 \u305d\u306e5","author":"LatB Staff","date":"2025\u5e7410\u670822\u65e5","format":false,"excerpt":"\u300c\u7d30\u80de\u57f9\u990a\u306e\u5b8c\u5168\u30b5\u30dd\u30fc\u30c8\u30ac\u30a4\u30c9\u300d\u306f\u3001\u7d30\u80de\u57f9\u990a\u306b\u521d\u3081\u3066\u6311\u6226\u3059\u308b\u65b9\u3084\u3001\u307e\u3060\u7d4c\u9a13\u306e\u6d45\u3044\u65b9\u306b\u5411\u3051\u3066\u3001\u57fa\u790e\u77e5\u8b58\u2026","rel":"","context":"\u7d30\u80de\u57f9\u990a\u30fb\u30a4\u30e1\u30fc\u30b8\u30f3\u30b0","block_context":{"text":"\u7d30\u80de\u57f9\u990a\u30fb\u30a4\u30e1\u30fc\u30b8\u30f3\u30b0","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/cell\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/10\/cell-culture-cell-culture-basic-bid-ts-mbr-25063_eyecatch-scaled.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/10\/cell-culture-cell-culture-basic-bid-ts-mbr-25063_eyecatch-scaled.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/10\/cell-culture-cell-culture-basic-bid-ts-mbr-25063_eyecatch-scaled.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/10\/cell-culture-cell-culture-basic-bid-ts-mbr-25063_eyecatch-scaled.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/10\/cell-culture-cell-culture-basic-bid-ts-mbr-25063_eyecatch-scaled.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/10\/cell-culture-cell-culture-basic-bid-ts-mbr-25063_eyecatch-scaled.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]}],"jetpack_sharing_enabled":true,"amp_enabled":true,"jetpack_featured_media_url":"","_links":{"self":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/posts\/6567","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/users\/975"}],"replies":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/comments?post=6567"}],"version-history":[{"count":0,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/posts\/6567\/revisions"}],"wp:attachment":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/media?parent=6567"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/categories?post=6567"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/tags?post=6567"},{"taxonomy":"division","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/division?post=6567"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}