{"id":6657,"date":"2020-05-27T14:13:32","date_gmt":"2020-05-27T05:13:32","guid":{"rendered":"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/?p=6657"},"modified":"2021-12-01T17:20:16","modified_gmt":"2021-12-01T08:20:16","slug":"bioanalyzer_ma_gsd_ts_1","status":"publish","type":"post","link":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/bioanalyzer_ma_gsd_ts_1\/","title":{"rendered":"\u30b5\u30f3\u30d7\u30eb\u30c1\u30a7\u30c3\u30af\u306b\u7c21\u4fbf\u3067\u624b\u65e9\u3044\uff01\u30d0\u30a4\u30aa\u30a2\u30ca\u30e9\u30a4\u30b6\u3092\u4f7f\u3063\u305f\u30b2\u30eb\u30b7\u30d5\u30c8\u30a2\u30c3\u30bb\u30a4\u6cd5"},"content":{"rendered":"<p><a href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/life-science\/microarray-analysis\/transcriptome-profiling-microarrays.html?CID=Gsd_mic_gex_r04_jp_cp1349_pjt5973_gsd00000_0so_blg_op_lgn_kt_s00_ma1_Social_LAB\" target=\"_blank\" rel=\"noopener noreferrer\">Applied Biosystems\u2122 GeneChip\u2122 \u30de\u30a4\u30af\u30ed\u30a2\u30ec\u30a4\u3092\u7528\u3044\u305f\u907a\u4f1d\u5b50\u767a\u73fe\u89e3\u6790\u5b9f\u9a13<\/a>\u3067\u306f\u3001\u7db2\u7f85\u7684\u306b\u907a\u4f1d\u5b50\u306e\u767a\u73fe\u5909\u52d5\u3092\u5bb9\u6613\u306b\u78ba\u8a8d\u3059\u308b\u3053\u3068\u304c\u53ef\u80fd\u306a\u305f\u3081\u3001\u6709\u7528\u306a\u89e3\u6790\u30c4\u30fc\u30eb\u3068\u306a\u308a\u307e\u3059\u3002<\/p>\n<p>\u3053\u306e\u3088\u3046\u306a\u5b9f\u9a13\u306e\u30b5\u30f3\u30d7\u30eb\u8abf\u88fd\u3067\u4f7f\u7528\u3059\u308bApplied Biosystems\u2122 <a href=\"https:\/\/www.thermofisher.com\/document-connect\/document-connect.html?url=https%3A%2F%2Fassets.thermofisher.com%2FTFS-Assets%2FLSG%2Fmanuals%2FMAN0018137_703174_WTPlus_Reagentkit_Assay_UG.pdf&amp;title=VXNlciBHdWlkZTogR2VuZUNoaXAgV1QgUExVUyBSZWFnZW50IEtpdCBNYW51YWwgVGFyZ2V0IFByZXBhcmF0aW9uIGZvciBHZW5lQ2hpcCBXaG9sZSBUcmFuc2NyaXB0IChXVCkgRXhwcmVzc2lvbiBBcnJheXM=?CID=Gsd_mic_gex_r04_jp_cp1349_pjt5973_gsd00000_0so_blg_op_lgn_kt_s00_ma1_Social_LAB\" target=\"_blank\" rel=\"noopener noreferrer\">GeneChip\u2122 WT PLUS Reagent Kit\u306e\u30a2\u30c3\u30bb\u30a4\u30de\u30cb\u30e5\u30a2\u30eb<\/a>\u306b\u306f\u3001\u30aa\u30d7\u30b7\u30e7\u30f3\u6271\u3044\u3067\u306f\u3042\u308a\u307e\u3059\u304c\u3001\u30d3\u30aa\u30c1\u30f3\u6a19\u8b58\u3057\u305f\u30b5\u30f3\u30d7\u30eb\u306e\u6a19\u8b58\u52b9\u7387\u3092\u78ba\u8a8d\u3059\u308b\u305f\u3081\u306b\u30b2\u30eb\u30b7\u30d5\u30c8\u30a2\u30c3\u30bb\u30a4\u3092\u884c\u3046\u3053\u3068\u304c\u8a18\u8f09\u3055\u308c\u3066\u3044\u307e\u3059\u3002<\/p>\n<p>\u3053\u306e\u30a2\u30c3\u30bb\u30a4\u306f\u3001\u6a19\u8b58\u52b9\u7387\u3092\u78ba\u8a8d\u3059\u308b\u3068\u4fe1\u983c\u6027\u306e\u9ad8\u3044\u60c5\u5831\u304c\u5f97\u3089\u308c\u308b\u305f\u3081\u3001\u30de\u30a4\u30af\u30ed\u30a2\u30ec\u30a4\u89e3\u6790\u306e\u53d7\u8a17\u89e3\u6790\u3092\u884c\u3063\u3066\u3044\u308b\u3088\u3046\u306a\u65bd\u8a2d\u3067\u306f\u554f\u984c\u306a\u304f\u30a2\u30c3\u30bb\u30a4\u304c\u884c\u308f\u308c\u305f\u304b\u3092\u30c1\u30a7\u30c3\u30af\u3067\u304d\u307e\u3059\u3002\u901a\u5e38\u3001\u3053\u306e\u30b2\u30eb\u30b7\u30d5\u30c8\u30a2\u30c3\u30bb\u30a4\u306b\u306f\u3001\u6e96\u5099\u3068\u64cd\u4f5c\u306b\u6642\u9593\u304c\u304b\u304b\u308a\u307e\u3059\u304c\u3001\u30a2\u30b8\u30ec\u30f3\u30c8\u793e\u306e\u30d0\u30a4\u30aa\u30a2\u30ca\u30e9\u30a4\u30b6\u3092\u4f7f\u7528\u3059\u308b\u3053\u3068\u304c\u53ef\u80fd\u306a\u65b9\u306f\u3001\u3088\u308a\u7c21\u4fbf\u306b\u3053\u308c\u3092\u78ba\u8a8d\u3059\u308b\u3053\u3068\u304c\u3067\u304d\u307e\u3059\u3002<\/p>\n<p>\u4eca\u56de\u306f\u3001\u3053\u306e\u30b2\u30eb\u30b7\u30d5\u30c8\u30a2\u30c3\u30bb\u30a4\u3092\u7c21\u4fbf\u306b\u901f\u304f\u884c\u3046\u5225\u6cd5\u3092\u3054\u7d39\u4ecb\u3057\u307e\u3059\u3002<br \/>\n\u25bc\u3053\u3093\u306a\u65b9\u306b\u304a\u3059\u3059\u3081\u3067\u3059\uff01<br \/>\n\u30fb\u30a2\u30b8\u30ec\u30f3\u30c8\u793e\u306e\u30d0\u30a4\u30aa\u30a2\u30ca\u30e9\u30b6\u3092\u4f7f\u7528\u3059\u308b\u3053\u3068\u304c\u53ef\u80fd\u306a\u65b9<br \/>\n\u30fb\u53d7\u8a17\u89e3\u6790\u30b5\u30fc\u30d3\u30b9\u3092\u884c\u3063\u3066\u3044\u308b\u65bd\u8a2d\u3067\u5b9f\u9a13\u3055\u308c\u3066\u3044\u308b\u65b9<br \/>\n\u30fb\u6697\u3044\u753b\u50cf\u30c7\u30fc\u30bf\u304c\u5f97\u3089\u308c\u305f\u6642\u306e\u30c8\u30e9\u30d6\u30eb\u30b7\u30e5\u30fc\u30c6\u30a3\u30f3\u30b0\u3092\u884c\u3044\u305f\u3044\u65b9<\/p>\n<h2>\u30a2\u30c3\u30bb\u30a4\u30de\u30cb\u30e5\u30a2\u30eb\u306b\u8a18\u8f09\u3055\u308c\u3066\u3044\u308b\u30b2\u30eb\u30b7\u30d5\u30c8\u30a2\u30c3\u30bb\u30a4\u6cd5<\/h2>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"size-full wp-image-6760 alignright\" src=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2020\/05\/picture1-5.jpg\" alt=\"\" width=\"178\" height=\"327\" srcset=\"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2020\/05\/picture1-5.jpg 178w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2020\/05\/picture1-5-163x300.jpg 163w\" sizes=\"auto, (max-width: 178px) 100vw, 178px\" \/>\u30a2\u30c3\u30bb\u30a4\u30de\u30cb\u30e5\u30a2\u30eb\u306eAppendix A \u306e\u7ae0\u3067\u7d39\u4ecb\u3055\u308c\u3066\u3044\u308b\u30b2\u30eb\u30b7\u30d5\u30c8\u30a2\u30c3\u30bb\u30a4\u6cd5\u306f\u6a19\u8b58\u53cd\u5fdc\u5f8c\u306b\u30d3\u30aa\u30c1\u30f3\u6a19\u8b58\u3057\u305f\u30b5\u30f3\u30d7\u30eb2\u03bcL\u3092\u63a1\u53d6\u3057\u3001\u305d\u306e\u3046\u3061\u306e1\u03bcL\u3092NeutrAvidin Protein\u3068\u53cd\u5fdc\u3055\u305b\u3066\u3001\u672a\u53cd\u5fdc\u306e\u6a19\u8b58\u30b5\u30f3\u30d7\u30eb\u3068\u4e00\u7dd2\u306b4\uff5e20%\u30a2\u30af\u30ea\u30eb\u30a2\u30df\u30c9\u30b2\u30eb\u96fb\u6c17\u6cf3\u52d5\u306b\u304b\u3051\u3066\u79fb\u52d5\u5ea6\u306e\u9055\u3044\u3092\u78ba\u8a8d\u3059\u308b\u65b9\u6cd5\u3067\u3059\u3002<\/p>\n<p>\u554f\u984c\u306a\u304f\u30d3\u30aa\u30c1\u30f3\u3067\u6a19\u8b58\u3055\u308c\u305f\u30b5\u30f3\u30d7\u30eb\u3067\u3042\u308c\u3070\u3001Lane2 \u306e\u3088\u3046\u306bNeutrAvidin Protein\u3068\u306e\u53cd\u5fdc\u7523\u7269\u306f\u9ad8\u5206\u5b50\u5074\u306b\u30b7\u30d5\u30c8\u3057\u305f\u7d50\u679c\u3068\u306a\u308a\u307e\u3059\u3002\u3057\u304b\u3057\u3001\u30a2\u30af\u30ea\u30eb\u30a2\u30df\u30c9\u30b2\u30eb\u96fb\u6c17\u6cf3\u52d5\u3092\u884c\u3063\u3066\u691c\u51fa\u3059\u308b\u305f\u3081\u306e\u8a66\u85ac\u3084\u88c5\u7f6e\u3001\u304a\u3088\u3073NeutrAvidin Protein\u3092\u5225\u9014\u7528\u610f\u3059\u308b\u5fc5\u8981\u304c\u3042\u308a\u307e\u3059\u3002<\/p>\n<p>&nbsp;<\/p>\n<h2>\u30d0\u30a4\u30aa\u30a2\u30ca\u30e9\u30b6\u3092\u7528\u3044\u305f\u30b2\u30eb\u30b7\u30d5\u30c8\u30a2\u30c3\u30bb\u30a4\u6cd5<\/h2>\n<p>\u30a2\u30b8\u30ec\u30f3\u30c8\u793e\u306e\u30d0\u30a4\u30aa\u30a2\u30ca\u30e9\u30b6\u3092\u4f7f\u7528\u3059\u308b\u3053\u3068\u304c\u53ef\u80fd\u3067\u3042\u308c\u3070\u3001\u6a19\u8b58\u53cd\u5fdc\u306e\u524d\u5de5\u7a0b\u3067\u3042\u308b\u65ad\u7247\u5316\u53cd\u5fdc\u30b5\u30f3\u30d7\u30eb\u3068\u4e00\u7dd2\u306b\u30c1\u30a7\u30c3\u30af\u3059\u308b\u3053\u3068\u3067\u3001\u554f\u984c\u306a\u304f\u30d3\u30aa\u30c1\u30f3\u3067\u6a19\u8b58\u3055\u308c\u305f\u304b\u3092\u78ba\u8a8d\u3067\u304d\u307e\u3059\u3002Agilent RNA 6000 \u30ca\u30ce\u30ad\u30c3\u30c8\u3092\u4f7f\u7528\u3057\u3001mRNA Nano Series II\u306e\u6761\u4ef6\u3067\u901a\u5e38\u306e\u64cd\u4f5c\u3092\u884c\u3044\u307e\u3059\u3002\u554f\u984c\u306a\u304f\u6a19\u8b58\u53cd\u5fdc\u304c\u884c\u308f\u308c\u3066\u3044\u308c\u3070\u3001\u65ad\u7247\u5316\u53cd\u5fdc\u30b5\u30f3\u30d7\u30eb\u3068\u30d3\u30aa\u30c1\u30f3\u6a19\u8b58\u53cd\u5fdc\u30b5\u30f3\u30d7\u30eb\u306e\u6cf3\u52d5\u30c8\u30ec\u30fc\u30b9\u3092\u91cd\u306d\u5408\u308f\u305b\u3066\u8868\u793a\u3057\u305f\u5834\u5408\u3001\u6a19\u8b58\u53cd\u5fdc\u30b5\u30f3\u30d7\u30eb\u30d4\u30fc\u30af\u304c\u65ad\u7247\u5316\u53cd\u5fdc\u30b5\u30f3\u30d7\u30eb\u30d4\u30fc\u30af\u3088\u308a\u308230\u5869\u57fa\u7a0b\u5ea6\u5f8c\u308d\u306b\u30b7\u30d5\u30c8\u3057\u3066\u3044\u308b\u3053\u3068\u304c\u78ba\u8a8d\u3067\u304d\u307e\u3059\u3002<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"size-full wp-image-6762 aligncenter\" src=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2020\/05\/picture2-3.jpg\" alt=\"\" width=\"429\" height=\"351\" srcset=\"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2020\/05\/picture2-3.jpg 429w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2020\/05\/picture2-3-300x245.jpg 300w\" sizes=\"auto, (max-width: 429px) 100vw, 429px\" \/><\/p>\n<p>\u30d0\u30a4\u30aa\u30a2\u30ca\u30e9\u30b6\u304c\u4f7f\u7528\u3067\u304d\u308b\u65bd\u8a2d\u9650\u5b9a\u306b\u306a\u3063\u3066\u3057\u307e\u3044\u307e\u3059\u304c\u3001\u7c21\u4fbf\u306b\u624b\u65e9\u304f\u30b2\u30eb\u30b7\u30d5\u30c8\u30a2\u30c3\u30bb\u30a4\u3092\u884c\u3046\u3053\u3068\u304c\u3067\u304d\u307e\u3059\u306e\u3067\u3001\u305c\u3072\u304a\u8a66\u3057\u304f\u3060\u3055\u3044\uff01<\/p>\n<p>\u6280\u8853\u30b5\u30fc\u30d3\u30b9\u306b\u95a2\u3059\u308b\u304a\u554f\u3044\u5408\u308f\u305b\u306f\u4ee5\u4e0b\u306e\u30da\u30fc\u30b8\u306b\u30a2\u30af\u30bb\u30b9\u3057\u3066\u304f\u3060\u3055\u3044\u3002<br \/>\n<a href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/products-and-services\/services\/technical-services\/inquiry.html?CID=Gsd_mic_gex_r04_jp_cp1349_pjt5973_gsd00000_0so_blg_op_lgn_kt_s00_ma1_Social_LAB\" target=\"_blank\" rel=\"noopener noreferrer\">https:\/\/www.thermofisher.com\/jp\/ja\/home\/products-and-services\/services\/technical-services\/inquiry.html<\/a><\/p>\n<p>&nbsp;<\/p>\n<p>\u7814\u7a76\u7528\u306b\u306e\u307f\u4f7f\u7528\u3067\u304d\u307e\u3059\u3002\u8a3a\u65ad\u7528\u306b\u306f\u4f7f\u7528\u3044\u305f\u3060\u3051\u307e\u305b\u3093\u3002<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Applied Biosystems\u2122 GeneChip\u2122 \u30de\u30a4\u30af\u30ed\u30a2\u30ec\u30a4\u3092\u7528\u3044\u305f\u907a\u4f1d\u5b50\u767a\u73fe\u89e3\u6790\u5b9f\u9a13\u3067\u306f\u3001\u7db2\u7f85\u7684\u306b\u907a\u4f1d\u5b50\u306e\u767a\u73fe\u5909\u52d5\u3092\u5bb9\u6613\u306b\u78ba\u8a8d\u3059\u308b\u3053\u3068\u304c\u53ef\u80fd\u306a\u305f\u3081\u3001\u6709\u7528\u306a\u89e3\u6790\u30c4\u30fc\u30eb\u3068\u306a\u308a\u307e\u3059\u3002 \u3053\u306e\u3088\u3046\u306a\u5b9f\u9a13\u306e\u30b5\u30f3\u30d7\u30eb\u8abf<\/p>\n","protected":false},"author":975,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_monsterinsights_skip_tracking":false,"_genesis_hide_title":false,"_genesis_hide_breadcrumbs":false,"_genesis_hide_singular_image":false,"_genesis_hide_footer_widgets":false,"_genesis_custom_body_class":"","_genesis_custom_post_class":"","_genesis_layout":"","_jetpack_newsletter_access":"","_jetpack_dont_email_post_to_subs":false,"_jetpack_newsletter_tier_id":0,"_jetpack_memberships_contains_paywalled_content":false,"_jetpack_feature_clip_id":0,"_jetpack_memberships_contains_paid_content":false,"footnotes":"","jetpack_post_was_ever_published":false},"categories":[156],"tags":[],"division":[],"class_list":{"0":"post-6657","1":"post","2":"type-post","3":"status-publish","4":"format-standard","6":"category-mol-bio","7":"entry"},"_selected_authors":"","_selected_reviewers":"","acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v27.8 (Yoast SEO v27.8) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>\u30b5\u30f3\u30d7\u30eb\u30c1\u30a7\u30c3\u30af\u306b\u7c21\u4fbf\u3067\u624b\u65e9\u3044\uff01\u30d0\u30a4\u30aa\u30a2\u30ca\u30e9\u30a4\u30b6\u3092\u4f7f\u3063\u305f\u30b2\u30eb\u30b7\u30d5\u30c8\u30a2\u30c3\u30bb\u30a4\u6cd5 - Learning at the Bench<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/bioanalyzer_ma_gsd_ts_1\/\" \/>\n<meta property=\"og:locale\" content=\"ja_JP\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"\u30b5\u30f3\u30d7\u30eb\u30c1\u30a7\u30c3\u30af\u306b\u7c21\u4fbf\u3067\u624b\u65e9\u3044\uff01\u30d0\u30a4\u30aa\u30a2\u30ca\u30e9\u30a4\u30b6\u3092\u4f7f\u3063\u305f\u30b2\u30eb\u30b7\u30d5\u30c8\u30a2\u30c3\u30bb\u30a4\u6cd5\" \/>\n<meta property=\"og:description\" content=\"Applied Biosystems\u2122 GeneChip\u2122 \u30de\u30a4\u30af\u30ed\u30a2\u30ec\u30a4\u3092\u7528\u3044\u305f\u907a\u4f1d\u5b50\u767a\u73fe\u89e3\u6790\u5b9f\u9a13\u3067\u306f\u3001\u7db2\u7f85\u7684\u306b\u907a\u4f1d\u5b50\u306e\u767a\u73fe\u5909\u52d5\u3092\u5bb9\u6613\u306b\u78ba\u8a8d\u3059\u308b\u3053\u3068\u304c\u53ef\u80fd\u306a\u305f\u3081\u3001\u6709\u7528\u306a\u89e3\u6790\u30c4\u30fc\u30eb\u3068\u306a\u308a\u307e\u3059\u3002 \u3053\u306e\u3088\u3046\u306a\u5b9f\u9a13\u306e\u30b5\u30f3\u30d7\u30eb\u8abf\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/bioanalyzer_ma_gsd_ts_1\/\" \/>\n<meta property=\"og:site_name\" content=\"Learning at the Bench\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/ThermoFisherJapan\" \/>\n<meta property=\"article:published_time\" content=\"2020-05-27T05:13:32+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2021-12-01T08:20:16+00:00\" \/>\n<meta property=\"og:image\" content=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2020\/05\/picture1-5.jpg\" \/>\n<meta name=\"author\" content=\"LatB Staff\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:creator\" content=\"@ThermoFisherJP\" \/>\n<meta name=\"twitter:site\" content=\"@ThermoFisherJP\" \/>\n<meta name=\"twitter:label1\" content=\"\u57f7\u7b46\u8005\" \/>\n\t<meta name=\"twitter:data1\" content=\"LatB Staff\" \/>\n\t<meta name=\"twitter:label2\" content=\"\u63a8\u5b9a\u8aad\u307f\u53d6\u308a\u6642\u9593\" \/>\n\t<meta name=\"twitter:data2\" content=\"1\u5206\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/bioanalyzer_ma_gsd_ts_1\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/bioanalyzer_ma_gsd_ts_1\\\/\"},\"author\":{\"name\":\"LatB Staff\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#\\\/schema\\\/person\\\/bdbe319a2001f279ddce6ab8eaad1253\"},\"headline\":\"\u30b5\u30f3\u30d7\u30eb\u30c1\u30a7\u30c3\u30af\u306b\u7c21\u4fbf\u3067\u624b\u65e9\u3044\uff01\u30d0\u30a4\u30aa\u30a2\u30ca\u30e9\u30a4\u30b6\u3092\u4f7f\u3063\u305f\u30b2\u30eb\u30b7\u30d5\u30c8\u30a2\u30c3\u30bb\u30a4\u6cd5\",\"datePublished\":\"2020-05-27T05:13:32+00:00\",\"dateModified\":\"2021-12-01T08:20:16+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/bioanalyzer_ma_gsd_ts_1\\\/\"},\"wordCount\":41,\"commentCount\":0,\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/bioanalyzer_ma_gsd_ts_1\\\/#primaryimage\"},\"thumbnailUrl\":\"http:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2020\\\/05\\\/picture1-5.jpg\",\"articleSection\":[\"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023\"],\"inLanguage\":\"ja\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/bioanalyzer_ma_gsd_ts_1\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/bioanalyzer_ma_gsd_ts_1\\\/\",\"url\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/bioanalyzer_ma_gsd_ts_1\\\/\",\"name\":\"\u30b5\u30f3\u30d7\u30eb\u30c1\u30a7\u30c3\u30af\u306b\u7c21\u4fbf\u3067\u624b\u65e9\u3044\uff01\u30d0\u30a4\u30aa\u30a2\u30ca\u30e9\u30a4\u30b6\u3092\u4f7f\u3063\u305f\u30b2\u30eb\u30b7\u30d5\u30c8\u30a2\u30c3\u30bb\u30a4\u6cd5 - Learning at the Bench\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/bioanalyzer_ma_gsd_ts_1\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/bioanalyzer_ma_gsd_ts_1\\\/#primaryimage\"},\"thumbnailUrl\":\"http:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2020\\\/05\\\/picture1-5.jpg\",\"datePublished\":\"2020-05-27T05:13:32+00:00\",\"dateModified\":\"2021-12-01T08:20:16+00:00\",\"author\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#\\\/schema\\\/person\\\/bdbe319a2001f279ddce6ab8eaad1253\"},\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/bioanalyzer_ma_gsd_ts_1\\\/#breadcrumb\"},\"inLanguage\":\"ja\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/bioanalyzer_ma_gsd_ts_1\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"ja\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/bioanalyzer_ma_gsd_ts_1\\\/#primaryimage\",\"url\":\"http:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2020\\\/05\\\/picture1-5.jpg\",\"contentUrl\":\"http:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2020\\\/05\\\/picture1-5.jpg\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/bioanalyzer_ma_gsd_ts_1\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"\u30b5\u30f3\u30d7\u30eb\u30c1\u30a7\u30c3\u30af\u306b\u7c21\u4fbf\u3067\u624b\u65e9\u3044\uff01\u30d0\u30a4\u30aa\u30a2\u30ca\u30e9\u30a4\u30b6\u3092\u4f7f\u3063\u305f\u30b2\u30eb\u30b7\u30d5\u30c8\u30a2\u30c3\u30bb\u30a4\u6cd5\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#website\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/\",\"name\":\"Learning at the Bench\",\"description\":\"\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"ja\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#\\\/schema\\\/person\\\/bdbe319a2001f279ddce6ab8eaad1253\",\"name\":\"LatB Staff\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"ja\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g\",\"caption\":\"LatB Staff\"},\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/author\\\/lgbadmin\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"\u30b5\u30f3\u30d7\u30eb\u30c1\u30a7\u30c3\u30af\u306b\u7c21\u4fbf\u3067\u624b\u65e9\u3044\uff01\u30d0\u30a4\u30aa\u30a2\u30ca\u30e9\u30a4\u30b6\u3092\u4f7f\u3063\u305f\u30b2\u30eb\u30b7\u30d5\u30c8\u30a2\u30c3\u30bb\u30a4\u6cd5 - Learning at the Bench","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/bioanalyzer_ma_gsd_ts_1\/","og_locale":"ja_JP","og_type":"article","og_title":"\u30b5\u30f3\u30d7\u30eb\u30c1\u30a7\u30c3\u30af\u306b\u7c21\u4fbf\u3067\u624b\u65e9\u3044\uff01\u30d0\u30a4\u30aa\u30a2\u30ca\u30e9\u30a4\u30b6\u3092\u4f7f\u3063\u305f\u30b2\u30eb\u30b7\u30d5\u30c8\u30a2\u30c3\u30bb\u30a4\u6cd5","og_description":"Applied Biosystems\u2122 GeneChip\u2122 \u30de\u30a4\u30af\u30ed\u30a2\u30ec\u30a4\u3092\u7528\u3044\u305f\u907a\u4f1d\u5b50\u767a\u73fe\u89e3\u6790\u5b9f\u9a13\u3067\u306f\u3001\u7db2\u7f85\u7684\u306b\u907a\u4f1d\u5b50\u306e\u767a\u73fe\u5909\u52d5\u3092\u5bb9\u6613\u306b\u78ba\u8a8d\u3059\u308b\u3053\u3068\u304c\u53ef\u80fd\u306a\u305f\u3081\u3001\u6709\u7528\u306a\u89e3\u6790\u30c4\u30fc\u30eb\u3068\u306a\u308a\u307e\u3059\u3002 \u3053\u306e\u3088\u3046\u306a\u5b9f\u9a13\u306e\u30b5\u30f3\u30d7\u30eb\u8abf","og_url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/bioanalyzer_ma_gsd_ts_1\/","og_site_name":"Learning at the Bench","article_publisher":"https:\/\/www.facebook.com\/ThermoFisherJapan","article_published_time":"2020-05-27T05:13:32+00:00","article_modified_time":"2021-12-01T08:20:16+00:00","og_image":[{"url":"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2020\/05\/picture1-5.jpg","type":"","width":"","height":""}],"author":"LatB Staff","twitter_card":"summary_large_image","twitter_creator":"@ThermoFisherJP","twitter_site":"@ThermoFisherJP","twitter_misc":{"\u57f7\u7b46\u8005":"LatB Staff","\u63a8\u5b9a\u8aad\u307f\u53d6\u308a\u6642\u9593":"1\u5206"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/bioanalyzer_ma_gsd_ts_1\/#article","isPartOf":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/bioanalyzer_ma_gsd_ts_1\/"},"author":{"name":"LatB Staff","@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#\/schema\/person\/bdbe319a2001f279ddce6ab8eaad1253"},"headline":"\u30b5\u30f3\u30d7\u30eb\u30c1\u30a7\u30c3\u30af\u306b\u7c21\u4fbf\u3067\u624b\u65e9\u3044\uff01\u30d0\u30a4\u30aa\u30a2\u30ca\u30e9\u30a4\u30b6\u3092\u4f7f\u3063\u305f\u30b2\u30eb\u30b7\u30d5\u30c8\u30a2\u30c3\u30bb\u30a4\u6cd5","datePublished":"2020-05-27T05:13:32+00:00","dateModified":"2021-12-01T08:20:16+00:00","mainEntityOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/bioanalyzer_ma_gsd_ts_1\/"},"wordCount":41,"commentCount":0,"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/bioanalyzer_ma_gsd_ts_1\/#primaryimage"},"thumbnailUrl":"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2020\/05\/picture1-5.jpg","articleSection":["\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023"],"inLanguage":"ja","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/bioanalyzer_ma_gsd_ts_1\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/bioanalyzer_ma_gsd_ts_1\/","url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/bioanalyzer_ma_gsd_ts_1\/","name":"\u30b5\u30f3\u30d7\u30eb\u30c1\u30a7\u30c3\u30af\u306b\u7c21\u4fbf\u3067\u624b\u65e9\u3044\uff01\u30d0\u30a4\u30aa\u30a2\u30ca\u30e9\u30a4\u30b6\u3092\u4f7f\u3063\u305f\u30b2\u30eb\u30b7\u30d5\u30c8\u30a2\u30c3\u30bb\u30a4\u6cd5 - Learning at the Bench","isPartOf":{"@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/bioanalyzer_ma_gsd_ts_1\/#primaryimage"},"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/bioanalyzer_ma_gsd_ts_1\/#primaryimage"},"thumbnailUrl":"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2020\/05\/picture1-5.jpg","datePublished":"2020-05-27T05:13:32+00:00","dateModified":"2021-12-01T08:20:16+00:00","author":{"@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#\/schema\/person\/bdbe319a2001f279ddce6ab8eaad1253"},"breadcrumb":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/bioanalyzer_ma_gsd_ts_1\/#breadcrumb"},"inLanguage":"ja","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/bioanalyzer_ma_gsd_ts_1\/"]}]},{"@type":"ImageObject","inLanguage":"ja","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/bioanalyzer_ma_gsd_ts_1\/#primaryimage","url":"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2020\/05\/picture1-5.jpg","contentUrl":"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2020\/05\/picture1-5.jpg"},{"@type":"BreadcrumbList","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/bioanalyzer_ma_gsd_ts_1\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/"},{"@type":"ListItem","position":2,"name":"\u30b5\u30f3\u30d7\u30eb\u30c1\u30a7\u30c3\u30af\u306b\u7c21\u4fbf\u3067\u624b\u65e9\u3044\uff01\u30d0\u30a4\u30aa\u30a2\u30ca\u30e9\u30a4\u30b6\u3092\u4f7f\u3063\u305f\u30b2\u30eb\u30b7\u30d5\u30c8\u30a2\u30c3\u30bb\u30a4\u6cd5"}]},{"@type":"WebSite","@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#website","url":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/","name":"Learning at the Bench","description":"","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"ja"},{"@type":"Person","@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#\/schema\/person\/bdbe319a2001f279ddce6ab8eaad1253","name":"LatB Staff","image":{"@type":"ImageObject","inLanguage":"ja","@id":"https:\/\/secure.gravatar.com\/avatar\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g","caption":"LatB Staff"},"url":"https:\/\/admin.acceleratingscience.com\/author\/lgbadmin\/"}]}},"taxonomy_info":{"category":[{"value":156,"label":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023"}]},"featured_image_src_large":false,"author_info":{"display_name":"LatB Staff","author_link":"https:\/\/admin.acceleratingscience.com\/author\/lgbadmin\/"},"comment_info":0,"category_info":[{"term_id":156,"name":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","slug":"mol-bio","term_group":0,"term_taxonomy_id":156,"taxonomy":"category","description":"","parent":0,"count":538,"filter":"raw","meta":[],"cat_ID":156,"category_count":538,"category_description":"","cat_name":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","category_nicename":"mol-bio","category_parent":0}],"tag_info":false,"jetpack-related-posts":[{"id":25325,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/exosome-gene-expression-ts-r-25019\/","url_meta":{"origin":6657,"position":0},"title":"\u3010\u7b2c5\u56de\u3011 &#8220;RNA cargo&#8221;\u306e\u7cbe\u88fd\u3068\u5b9a\u91cf\u89e3\u6790\u300d\uff5emRNA\u306e\u5b9a\u91cf\u89e3\u6790\uff5e","author":"LatB Staff","date":"2026\u5e746\u670811\u65e5","format":false,"excerpt":"\u4eca\u56de\u306f\u3001\u30a8\u30af\u30bd\u30bd\u30fc\u30e0\uff08\u30a8\u30ad\u30bd\u30bd\u30fc\u30e0\uff09\u4e2d\u306emRNA\u306e\u5b9a\u91cf\u89e3\u6790\u306b\u3064\u3044\u3066\u8aac\u660e\u3057\u307e\u3059\u3002\u7b2c3\u56de\u3067\u30a8\u30af\u30bd\u30bd\u30fc\u30e0\u304b\u2026","rel":"","context":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","block_context":{"text":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/mol-bio\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25018_eyecatch-1.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25018_eyecatch-1.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25018_eyecatch-1.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25018_eyecatch-1.jpg?resize=700%2C400&ssl=1 2x"},"classes":[]},{"id":25247,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/exosome-gene-expression-ts-r-25018\/","url_meta":{"origin":6657,"position":1},"title":"\u3010\u7b2c4\u56de\u3011&#8221;RNA cargo&#8221;\u306e\u7cbe\u88fd\u3068\u5b9a\u91cf\u89e3\u6790\uff5emiRNA\u306e\u5b9a\u91cf\u89e3\u6790\uff5e","author":"LatB Staff","date":"2026\u5e745\u670829\u65e5","format":false,"excerpt":"\u524d\u56de\uff08\u3010\u7b2c3\u56de\u3011\u201cRNA cargo\u201d\u306e\u7cbe\u88fd\u3068\u5b9a\u91cf\u89e3\u6790\uff09\u3067\u306f\u3001\u30a8\u30af\u30bd\u30bd\u30fc\u30e0 \uff08\u30a8\u30ad\u30bd\u30bd\u30fc\u30e0\uff09 \u304b\u3089\u306e\u2026","rel":"","context":"\u5206\u6790\u30fb\u6e2c\u5b9a\u95a2\u9023","block_context":{"text":"\u5206\u6790\u30fb\u6e2c\u5b9a\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/analysis\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25018_eyecatch-1.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25018_eyecatch-1.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25018_eyecatch-1.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25018_eyecatch-1.jpg?resize=700%2C400&ssl=1 2x"},"classes":[]},{"id":24187,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/ngs-gene-expression-csd-ts-ion-25073\/","url_meta":{"origin":6657,"position":2},"title":"\u3010\u3084\u3063\u3066\u307f\u305f\u3011\u5fae\u91cf\u30fb\u5206\u89e3RNA\u306b\u3088\u308b\u767a\u73fe\u89e3\u6790\u306e\u6700\u9069\u89e3\u306f\uff1fRNA-Seq\u3068Ion AmpliSeq Transcriptome\u3092\u6bd4\u3079\u3066\u307f\u305f","author":"LatB Staff","date":"2025\u5e7411\u670828\u65e5","format":false,"excerpt":"\u6b21\u4e16\u4ee3\u30b7\u30fc\u30b1\u30f3\u30b5\u3067\u306e\u767a\u73fe\u89e3\u6790\u306b\u53d6\u308a\u7d44\u3080\u969b\u3001RNA\u30b5\u30f3\u30d7\u30eb\u304c\u300c\u5c11\u306a\u3059\u304e\u308b\u300d\u300c\u5206\u89e3\u3057\u3066\u3044\u308b\u300d\u3068\u3044\u3046\u72b6\u6cc1\u306f\u2026","rel":"","context":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","block_context":{"text":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/mol-bio\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/11\/ngs-gene-expression-csd-ts-ion-25073_eyecatch-scaled.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/11\/ngs-gene-expression-csd-ts-ion-25073_eyecatch-scaled.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/11\/ngs-gene-expression-csd-ts-ion-25073_eyecatch-scaled.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/11\/ngs-gene-expression-csd-ts-ion-25073_eyecatch-scaled.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/11\/ngs-gene-expression-csd-ts-ion-25073_eyecatch-scaled.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/11\/ngs-gene-expression-csd-ts-ion-25073_eyecatch-scaled.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":23239,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/ngs-gene-expression-csd-ts-bfx-25060\/","url_meta":{"origin":6657,"position":3},"title":"\u98df\u54c1\u958b\u767a\u306b\u304a\u3051\u308b\u83cc\u53e2\u89e3\u6790\u3068\u907a\u4f1d\u5b50\u767a\u73fe\u89e3\u6790\u306e\u6d3b\u7528","author":"LatB Staff","date":"2025\u5e7410\u67088\u65e5","format":false,"excerpt":"\u907a\u4f1d\u5b50\u95a2\u9023\u306e\u89e3\u6790\u6280\u8853\u304c\u7814\u7a76\u306e\u307f\u306a\u3089\u305a\u7523\u696d\u5206\u91ce\u3067\u6d3b\u7528\u3055\u308c\u308b\u3088\u3046\u306b\u306a\u308a\u3001\u5e74\u6708\u304c\u7d4c\u904e\u3059\u308b\u306b\u3064\u308c\u3066\u5fdc\u7528\u7bc4\u56f2\u3082\u2026","rel":"","context":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","block_context":{"text":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/mol-bio\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/09\/ngs-gene-expression-gsd-ts-tr-25060_eyecatch.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/09\/ngs-gene-expression-gsd-ts-tr-25060_eyecatch.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/09\/ngs-gene-expression-gsd-ts-tr-25060_eyecatch.jpg?resize=525%2C300&ssl=1 1.5x"},"classes":[]},{"id":24647,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/sanger-seq-mutational-analysis-gsd-ts-ce-26007\/","url_meta":{"origin":6657,"position":4},"title":"\u30de\u30a4\u30ca\u30fc\u5909\u7570\u3092\u691c\u51fa\uff01Minor Variant Finder\u30bd\u30d5\u30c8\u30a6\u30a8\u30a2","author":"LatB Staff","date":"2026\u5e742\u67089\u65e5","format":false,"excerpt":"\u30ad\u30e3\u30d4\u30e9\u30ea\u30fc\u30b7\u30fc\u30b1\u30f3\u30b5\u3067\u306f\u300125%\u7a0b\u5ea6\u306e\u5272\u5408\u306e\u5909\u7570\u3092\u691c\u51fa\u3059\u308b\u3053\u3068\u304c\u3067\u304d\u307e\u3059\u304c\u3001\u3053\u308c\u3088\u308a\u3082\u4f4e\u3044\u5272\u5408\u306e\u5909\u2026","rel":"","context":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","block_context":{"text":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/mol-bio\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/01\/sanger-seq-mutational-analysis-gsd-ts-ce-26007_eyecatch.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/01\/sanger-seq-mutational-analysis-gsd-ts-ce-26007_eyecatch.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/01\/sanger-seq-mutational-analysis-gsd-ts-ce-26007_eyecatch.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/01\/sanger-seq-mutational-analysis-gsd-ts-ce-26007_eyecatch.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/01\/sanger-seq-mutational-analysis-gsd-ts-ce-26007_eyecatch.jpg?resize=1050%2C600&ssl=1 3x"},"classes":[]},{"id":25565,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/exosome-antibody-ts-r-25068_\/","url_meta":{"origin":6657,"position":5},"title":"\u3010\u7b2c8\u56de\u3011\u30a8\u30af\u30bd\u30bd\u30fc\u30e0\u30b5\u30d6\u30bf\u30a4\u30d7\u306e\u5206\u753b\u6cd5 \uff1a \u30a6\u30a7\u30b9\u30bf\u30f3\u30d6\u30ed\u30c3\u30c8\uff0fqRT-PCR\uff0f\u30b7\u30fc\u30b1\u30f3\u30b9\u89e3\u6790\u306b\u9069\u3057\u305f\u5206\u753b\u65b9\u6cd5","author":"LatB Staff","date":"2026\u5e749\u670829\u65e5","format":false,"excerpt":"\u672c\u7a3f\u3067\u306f\u3001\u30a8\u30af\u30bd\u30bd\u30fc\u30e0\u819c\u4e0a\u306e\u7279\u5b9a\u306e\u30bf\u30f3\u30d1\u30af\u8cea\u3092\u6a19\u7684\u3068\u3057\u305f\u514d\u75ab\u5438\u7740\u6cd5\u306b\u57fa\u3065\u304f\u5206\u753b\u624b\u6cd5\u3092\u7d39\u4ecb\u3057\u307e\u3059\u3002\u30a8\u30af\u2026","rel":"","context":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","block_context":{"text":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/mol-bio\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25019_eyecatch.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25019_eyecatch.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25019_eyecatch.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25019_eyecatch.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25019_eyecatch.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25019_eyecatch.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]}],"jetpack_sharing_enabled":true,"amp_enabled":true,"jetpack_featured_media_url":"","_links":{"self":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/posts\/6657","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/users\/975"}],"replies":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/comments?post=6657"}],"version-history":[{"count":0,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/posts\/6657\/revisions"}],"wp:attachment":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/media?parent=6657"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/categories?post=6657"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/tags?post=6657"},{"taxonomy":"division","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/division?post=6657"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}