{"id":681,"date":"2017-03-09T00:00:00","date_gmt":"2017-03-09T00:00:00","guid":{"rendered":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/qpcr-basic39\/"},"modified":"2025-04-16T15:25:18","modified_gmt":"2025-04-16T06:25:18","slug":"qpcr-basic39","status":"publish","type":"post","link":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/qpcr-basic39\/","title":{"rendered":"\u7570\u306a\u308bPCR\u7523\u7269\u3092\u8b58\u5225\u3067\u304d\u308b\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u306e\u89e3\u96e2\u66f2\u7dda\u89e3\u6790\u3068\u306f\uff1f"},"content":{"rendered":"<p>\u89e3\u96e2\u66f2\u7dda\u89e3\u6790\u306f\u3001\u30d7\u30e9\u30a4\u30de\u30fc\u30c0\u30a4\u30de\u30fc\u526f\u7523\u7269\u7b49\u304c\u5b58\u5728\u3059\u308b\u304b\u3069\u3046\u304bPCR\u7523\u7269\u3092\u8abf\u3079\u3001\u53cd\u5fdc\u7279\u7570\u6027\u3092\u78ba\u8a8d\u3059\u308b\u305f\u3081\u306e\u3001\u7c21\u4fbf\u3067\u660e\u77ad\u306a\u65b9\u6cd5\u3067\u3059\u3002\u6838\u9178\u306eTm\u306f\u3001\u7a2e\u3005\u306e\u8981\u56e0\u306e\u3046\u3061\u3001\u9396\u306e\u9577\u3055\u3001GC\u542b\u91cf\u304a\u3088\u3073\u5869\u57fa\u306e\u30df\u30b9\u30de\u30c3\u30c1\u306b\u3088\u308a\u5f71\u97ff\u3055\u308c\u308b\u305f\u3081\u3001\u591a\u304f\u306e\u5834\u5408\u878d\u89e3\u7279\u6027\u306b\u3088\u308a\u3001\u7570\u306a\u308bPCR\u7523\u7269\u3092\u8b58\u5225\u3059\u308b\u3053\u3068\u304c\u53ef\u80fd\u3067\u3059\u3002\u4eca\u56de\u306f\u3001\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u3092\u5229\u7528\u3057\u305f\u89e3\u96e2\u66f2\u7dda\u89e3\u6790\u306e\u6982\u8981\u3068\u89e3\u6790\u65b9\u6cd5\u306b\u3064\u3044\u3066\u3054\u7d39\u4ecb\u3057\u307e\u3059\u3002<\/p>\n<h2>\u89e3\u96e2\u66f2\u7dda\u89e3\u6790\u304a\u3088\u3073\u691c\u51fa\u30b7\u30b9\u30c6\u30e0<\/h2>\n<p><strong>\u89e3\u96e2\u66f2\u7dda\u89e3\u6790\u306f\u3001\u86cd\u5149\u7269\u8cea\u304c\u30a2\u30f3\u30d7\u30ea\u30b3\u30f3\u306b\u7d50\u5408\u3057\u305f\u72b6\u614b\u3092\u4fdd\u3064\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u691c\u51fa\u7cfb\u3067\u306e\u307f\u884c\u3046\u3053\u3068\u304c\u3067\u304d\u307e\u3059\u3002<\/strong>Applied Biosystems\u2122 SYBR\u2122 Green I\u8272\u7d20\u307e\u305f\u306fApplied Biosystems\u2122 SYBR\u2122 GreenER\u2122 \u8272\u7d20\u3092\u4f7f\u7528\u3057\u305f\u5897\u5e45\u3057\u305f\u53cd\u5fdc\u7cfb\u3067\u306f\u6e29\u5ea6\u89e3\u96e2\u66f2\u7dda\u89e3\u6790\u3092\u884c\u3046\u3053\u3068\u304c\u3067\u304d\u307e\u3059\u3002TaqMan \u30d7\u30ed\u30fc\u30d6\u306e\u3088\u3046\u306b2 \u91cd\u6a19\u8b58\u3055\u308c\u305f\u30d7\u30ed\u30fc\u30d6\u306f\u3001PCR\u4e2d\u306b\u86cd\u5149\u7269\u8cea\u3092\u53cd\u5fdc\u6eb6\u6db2\u4e2d\u306b\u653e\u51fa\u3059\u308b\u3053\u3068\u306b\u3088\u308a\u3001\u30b7\u30b0\u30ca\u30eb\u306b\u975e\u53ef\u9006\u7684\u306a\u5909\u5316\u3092\u751f\u3058\u308b\u305f\u3081\u3001\u89e3\u96e2\u66f2\u7dda\u89e3\u6790\u3092\u884c\u3046\u3053\u3068\u306f\u3067\u304d\u307e\u305b\u3093\u3002\u3057\u304b\u3057\u3001\u3053\u308c\u3089\u306e\u65b9\u6cd5\u306f\u7279\u7570\u6027\u306e\u9ad8\u3044\u306e\u3067\u89e3\u96e2\u66f2\u7dda\u89e3\u6790\u304c\u3067\u304d\u306a\u3044\u3053\u3068\u306f\u5927\u304d\u306a\u554f\u984c\u3068\u306f\u306a\u308a\u307e\u305b\u3093\u3002<\/p>\n<p>SYBR Green I \u8272\u7d20\u304a\u3088\u3073SYBR GreenER\u8272\u7d20\u306e\u86cd\u5149\u30ec\u30d9\u30eb\u306f\u3044\u305a\u308c\u3082\u4e8c\u672c\u9396DNA\u306b\u7d50\u5408\u3059\u308b\u3068\u8457\u3057\u304f\u4e0a\u6607\u3057\u307e\u3059\u3002\u4e8c\u672c\u9396DNA\u306e\u89e3\u96e2\u3092\u3053\u306e\u86cd\u5149\u30ec\u30d9\u30eb\u3067\u30e2\u30cb\u30bf\u30fc\u3059\u308b\u3068\u3001DNA\u304c\u4e00\u672c\u9396\u306b\u306a\u308a\u8272\u7d20\u304cDNA\u304b\u3089\u904a\u96e2\u3059\u308b\u3068\u540c\u6642\u306b\u86cd\u5149\u306e\u4f4e\u4e0b\u304c\u691c\u51fa\u3055\u308c\u307e\u3059\u3002<\/p>\n<h2>\u89e3\u96e2\u66f2\u7dda\u89e3\u6790\u306e\u91cd\u8981\u6027<\/h2>\n<p><strong>\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u306e\u7279\u7570\u6027\u306f\u4f7f\u7528\u3059\u308b\u30d7\u30e9\u30a4\u30de\u30fc\u304a\u3088\u3073\u53cd\u5fdc\u6761\u4ef6\u306b\u3088\u3063\u3066\u6c7a\u307e\u308a\u307e\u3059\u3002<\/strong>\u975e\u5e38\u306b\u826f\u597d\u306b\u30c7\u30b6\u30a4\u30f3\u3055\u308c\u305f\u30d7\u30e9\u30a4\u30de\u30fc\u3067\u3082\u30d7\u30e9\u30a4\u30de\u30fc\u30c0\u30a4\u30de\u30fc\u3092\u5f62\u6210\u3057\u305f\u308a\u975e\u7279\u7570\u7684\u7523\u7269\u3092\u5897\u5e45\u3059\u308b\u53ef\u80fd\u6027\u304c\u5e38\u306b\u5b58\u5728\u3057\u307e\u3059\uff08\u56f31\uff09\u3002\u307e\u305f\u3001\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u3092\u884c\u3046\u969b\u306b\u306f\u3001RNA\u8a66\u6599\u304c\u30b2\u30ce\u30e0DNA\u3092\u542b\u307f\u3001\u305d\u306eDNA\u304c\u5897\u5e45\u3055\u308c\u308b\u53ef\u80fd\u6027\u3082\u5b58\u5728\u3057\u307e\u3059\u3002\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u306e\u7279\u7570\u6027\u306f\u878d\u89e3\u66f2\u7dda\u89e3\u6790\u3092\u7528\u3044\u3066\u78ba\u8a8d\u3059\u308b\u3053\u3068\u304c\u53ef\u80fd\u3067\u3059\u3002\u878d\u89e3\u66f2\u7dda\u89e3\u6790\u3092\u884c\u3046\u3053\u3068\u304c\u3067\u304d\u306a\u3044\u5834\u5408\u306b\u306f\u3001\u53cd\u5fdc\u9593\u306eCt\u5024\u306e\u5dee\u304c\u59a5\u5f53\u306a\u3082\u306e\u3067\u3042\u308a\u3001\u975e\u7279\u7570\u7684\u7523\u7269\u306e\u5b58\u5728\u306b\u8d77\u56e0\u3059\u308b\u3082\u306e\u3067\u306f\u306a\u3044\u3053\u3068\u3092\u78ba\u8a8d\u3059\u308b\u305f\u3081\u306e\u8ffd\u52a0\u691c\u8a3c\u304c\u5fc5\u8981\u3067\u3059\u3002<\/p>\n<div id=\"attachment_1853\" style=\"width: 721px\" class=\"wp-caption aligncenter\"><a href=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/qpcr-basic39-fig1.png\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-1853\" class=\"size-full wp-image-1853\" src=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/qpcr-basic39-fig1.png\" alt=\"qpcr-basic39-fig1\" width=\"711\" height=\"556\" \/><\/a><p id=\"caption-attachment-1853\" class=\"wp-caption-text\">\u56f31 \u89e3\u96e2\u66f2\u7dda\u89e3\u6790\u306b\u3088\u308a\u3001\u89e3\u96e2\u66f2\u7dda\u306b\u304a\u3044\u3066\u5897\u5e45\u7523\u7269\u306e\u30d4\u30fc\u30af\u306e\u5de6\u5074\u306b\u898b\u3089\u308c\u308b\u8ffd\u52a0\u30d4\u30fc\u30af\u3068\u3057\u3066\u793a\u3055\u308c\u308b\u3001\u30d7\u30e9\u30a4\u30de\u30fc\u30c0\u30a4\u30de\u30fc\u306a\u3069\u306e\u975e\u7279\u7570\u7684\u7523\u7269\u306e\u5b58\u5728\u3092\u691c\u51fa\u3059\u308b\u3053\u3068\u304c\u53ef\u80fd\u3067\u3059\u3002<\/p><\/div>\n<h2>\u89e3\u96e2\u66f2\u7dda\u89e3\u6790\u3068\u30d7\u30e9\u30a4\u30de\u30fc\u30c0\u30a4\u30de\u30fc<\/h2>\n<p><strong>\u30d7\u30e9\u30a4\u30de\u30fc\u30c0\u30a4\u30de\u30fc\u306f2\u672c\u306ePCR\u30d7\u30e9\u30a4\u30de\u30fc\uff08\u540c\u4e00\u30d7\u30e9\u30a4\u30de\u30fc\u540c\u58eb\u53ca\u3073\u7570\u306a\u308b\u30d7\u30e9\u30a4\u30de\u30fc\u540c\u58eb\u306e\u3044\u305a\u308c\u3082\uff09\u304c\u3001\u30bf\u30fc\u30b2\u30c3\u30c8\u306e\u4ee3\u308f\u308a\u306b\u304a\u4e92\u3044\u306b\u7d50\u5408\u3057\u3042\u3046\u3053\u3068\u306b\u3088\u308a\u5f62\u6210\u3055\u308c\u307e\u3059\u3002<\/strong>\u30d7\u30e9\u30a4\u30de\u30fc\u30c0\u30a4\u30de\u30fc\u306eTm \u5024\u306f\u30a2\u30f3\u30d7\u30ea\u30b3\u30f3\u306eTm \u5024\u3088\u308a\u3082\u4f4e\u3044\u305f\u3081\u3001\u89e3\u96e2\u66f2\u7dda\u89e3\u6790\u306b\u3088\u308a\u30d7\u30e9\u30a4\u30de\u30fc\u30c0\u30a4\u30de\u30fc\u306e\u5b58\u5728\u3092\u78ba\u8a8d\u3067\u304d\u307e\u3059\u3002\u30c6\u30f3\u30d7\u30ec\u30fc\u30c8\u3092\u542b\u3080\u30b5\u30f3\u30d7\u30eb\u4e2d\u306b\u304a\u3051\u308b\u30d7\u30e9\u30a4\u30de\u30fc\u30c0\u30a4\u30de\u30fc\u306e\u5b58\u5728\u306f\u3001PCR\u52b9\u7387\u3092\u4f4e\u4e0b\u3055\u305b\u89e3\u6790\u304c\u4e0d\u660e\u77ad\u3068\u306a\u308b\u305f\u3081\u3001\u597d\u307e\u3057\u304f\u3042\u308a\u307e\u305b\u3093\u3002\u30d7\u30e9\u30a4\u30de\u30fc\u30c0\u30a4\u30de\u30fc\u306f\u3001\u30d7\u30e9\u30a4\u30de\u30fc\u304c\u5341\u5206\u306b\u5b58\u5728\u3057\u30c6\u30f3\u30d7\u30ec\u30fc\u30c8\u304c\u5b58\u5728\u3057\u306a\u3044\u72b6\u614b\u3067\u3042\u308b\u30c6\u30f3\u30d7\u30ec\u30fc\u30c8\u306a\u3057\u306e\u6761\u4ef6\uff08NTC\uff09\u3067\u6700\u3082\u983b\u7e41\u306b\u5f62\u6210\u3055\u308c\u307e\u3059\u3002NTC\u306b\u304a\u3051\u308b\u30d7\u30e9\u30a4\u30de\u30fc\u30c0\u30a4\u30de\u30fc\u306e\u5b58\u5728\u306f\u3001\u30c6\u30f3\u30d7\u30ec\u30fc\u30c8\u3092\u542b\u3080\u53cd\u5fdc\u4e2d\u306b\u3082\u30d7\u30e9\u30a4\u30de\u30fc\u30c0\u30a4\u30de\u30fc\u304c\u5b58\u5728\u3059\u308b\u3068\u3044\u3046\u3053\u3068\u3092\u610f\u5473\u3057\u307e\u3059\u3002NTC\u306b\u30d7\u30e9\u30a4\u30de\u30fc\u30c0\u30a4\u30de\u30fc\u304c\u8a8d\u3081\u3089\u308c\u305f\u5834\u5408\u306b\u306f\u3001\u30d7\u30e9\u30a4\u30de\u30fc\u306e\u30c7\u30b6\u30a4\u30f3\u3092\u898b\u76f4\u3059\u3053\u3068\u304c\u5fc5\u8981\u3067\u3059\u3002NTC\u306e\u878d\u89e3\u66f2\u7dda\u89e3\u6790\u306b\u3088\u308a\u3001\u30d7\u30e9\u30a4\u30de\u30fc\u30c0\u30a4\u30de\u30fc\u3068\u8a66\u85ac\u7d44\u6210\u306b\u542b\u307e\u308c\u308b\u30b3\u30f3\u30bf\u30df\u3057\u3066\u3044\u308b\u6838\u9178\u306b\u3088\u308b\u7591\u4f3c\u5897\u5e45\u3092\u8b58\u5225\u3059\u308b\u3053\u3068\u304c\u53ef\u80fd\u3067\u3059\u3002<\/p>\n<h2>\u89e3\u96e2\u66f2\u7dda\u89e3\u6790\u306e\u65b9\u6cd5<\/h2>\n<p><strong>\u89e3\u96e2\u66f2\u7dda\u89e3\u6790\u3092\u884c\u3046\u305f\u3081\u306b\u3001\u30b5\u30fc\u30de\u30eb\u30b5\u30a4\u30af\u30ea\u30f3\u30b0\u30d7\u30ed\u30c8\u30b3\u30eb\u306e\u76f4\u5f8c\u306b\u878d\u89e3\u30d7\u30ed\u30d5\u30a1\u30a4\u30eb\u3092\u7d44\u3080\u3088\u3046\u306b\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u88c5\u7f6e\u3092\u30d7\u30ed\u30b0\u30e9\u30e0\u3059\u308b\u3053\u3068\u304c\u53ef\u80fd\u3067\u3059\u3002<\/strong>\u5897\u5e45\u304c\u5b8c\u4e86\u3057\u305f\u5f8c\u306b\u3001\u5897\u5e45\u7523\u7269\u3092\u52a0\u71b1\u3057\u3066\u5b8c\u5168\u306a\u89e3\u96e2\u66f2\u7dda\u30c7\u30fc\u30bf\u3092\u56de\u53ce\u3057\u307e\u3059\uff08\u56f32\uff09\u3002\u73fe\u5728\u307b\u3068\u3093\u3069\u306e\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u88c5\u7f6e\u306b\u304a\u3044\u3066\u3001\u89e3\u6790\u30d1\u30c3\u30b1\u30fc\u30b8\u306b\u3053\u306e\u6a5f\u80fd\u304c\u7d44\u307f\u8fbc\u307e\u308c\u3066\u3044\u307e\u3059\u3002<\/p>\n<div id=\"attachment_1854\" style=\"width: 734px\" class=\"wp-caption aligncenter\"><a href=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/qpcr-basic39-fig2.png\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-1854\" class=\"size-full wp-image-1854\" src=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/qpcr-basic39-fig2.png\" alt=\"qpcr-basic39-fig2\" width=\"724\" height=\"514\" \/><\/a><p id=\"caption-attachment-1854\" class=\"wp-caption-text\">\u56f32 Applied Biosystems \u88c5\u7f6e\u4e0a\u3067\u306e\u89e3\u96e2\u66f2\u7dda\u30b5\u30fc\u30de\u30eb\u30d7\u30ed\u30d5\u30a1\u30a4\u30eb\u8a2d\u5b9a\u306e\u4f8b\u3092\u793a\u3057\u3066\u3044\u307e\u3059\uff08DNA\u5909\u6027\u306e\u305f\u3081\u306b94\u00b0C\u307e\u3067\u6025\u901f\u306b\u52a0\u71b1\u3057\u3001\u7d9a\u3044\u306660\u00b0C\u307e\u3067\u51b7\u5374\u3057\u307e\u3057\u305f\uff09\u3002<\/p><\/div>\n<p>&nbsp;<\/p>\n<h2>\u3010\u7121\u6599\u516c\u958b\u4e2d\u3011\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u30cf\u30f3\u30c9\u30d6\u30c3\u30af<\/h2>\n<p>\u3053\u306e\u30cf\u30f3\u30c9\u30d6\u30c3\u30af\u3067\u306f\u3001\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u306e\u7406\u8ad6\u3084\u5b9f\u9a13\u30c7\u30b6\u30a4\u30f3\u306e\u8a2d\u8a08\u306a\u3069\u3001\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u306e\u57fa\u790e\u77e5\u8b58\u304c\u63b2\u8f09\u3055\u308c\u3066\u3044\u307e\u3059\u3002\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u3092\u59cb\u3081\u305f\u3070\u304b\u308a\u306e\u65b9\u3084\u3053\u308c\u304b\u3089\u5b9f\u9a13\u3092\u8003\u3048\u3066\u3044\u308b\u65b9\u306b\u3046\u3063\u3066\u3064\u3051\u306e\u30cf\u30f3\u30c9\u30d6\u30c3\u30af\u3067\u3059\u3002PDF\u30d5\u30a1\u30a4\u30eb\u306e\u30c0\u30a6\u30f3\u30ed\u30fc\u30c9\u3092\u3054\u5e0c\u671b\u306e\u65b9\u306f\u3001\u4e0b\u8a18\u30dc\u30bf\u30f3\u3088\u308a\u304a\u7533\u3057\u8fbc\u307f\u304f\u3060\u3055\u3044\u3002<\/p>\n<p><a class=\"btn btn-red\" href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/global\/forms\/real-time-pcr-handbook-form.html?CID=gsd_pcr_sbu_r04_jp_cp0000_pjt0000_gsd00000_0so_blg_op_awa_oc_s00_qpcr45_Social_LAB\" target=\"_blank\" rel=\"noopener\">\u30c0\u30a6\u30f3\u30ed\u30fc\u30c9\u3059\u308b<\/a><\/p>\n<h2>\u3010\u7121\u6599\u516c\u958b\u4e2d\u3011\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u30c8\u30e9\u30d6\u30eb\u30b7\u30e5\u30fc\u30c6\u30a3\u30f3\u30b0<\/h2>\n<p>\u7570\u5e38\u306aS\u5b57\u72b6\u306e\u5897\u5e45\u66f2\u7dda\u3001NTC\u3067\u306e\u5897\u5e45\u691c\u51fa\u3001\u5897\u5e45\u304c\u898b\u3089\u308c\u306a\u3044\u306a\u3069\u3001\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u306e\u5b9f\u9a13\u4e2d\u306b\u56f0\u3063\u305f\u969b\u306e\u624b\u52a9\u3051\u306b\u306a\u308b\u60c5\u5831\u3092\u7d39\u4ecb\u3057\u3066\u3044\u307e\u3059\u3002PDF\u30d5\u30a1\u30a4\u30eb\u306e\u30c0\u30a6\u30f3\u30ed\u30fc\u30c9\u3092\u3054\u5e0c\u671b\u306e\u65b9\u306f\u3001\u4e0b\u8a18\u30dc\u30bf\u30f3\u3088\u308a\u304a\u7533\u3057\u8fbc\u307f\u304f\u3060\u3055\u3044\u3002<\/p>\n<p><a class=\"btn btn-red\" href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/global\/forms\/pcr-system-troubleshooting.html?CID=gsd_pcr_sbu_r04_jp_cp0000_pjt0000_gsd00000_0so_blg_op_awa_oc_s00_qpcr45_Social_LAB\" target=\"_blank\" rel=\"noopener\">\u30c0\u30a6\u30f3\u30ed\u30fc\u30c9\u3059\u308b<\/a><\/p>\n<p>&nbsp;<\/p>\n<p>\u7814\u7a76\u7528\u306b\u306e\u307f\u4f7f\u7528\u3067\u304d\u307e\u3059\u3002\u8a3a\u65ad\u7528\u306b\u306f\u4f7f\u7528\u3044\u305f\u3060\u3051\u307e\u305b\u3093\u3002<\/p>\n","protected":false},"excerpt":{"rendered":"<p>\u89e3\u96e2\u66f2\u7dda\u89e3\u6790\u306f\u3001\u30d7\u30e9\u30a4\u30de\u30fc\u30c0\u30a4\u30de\u30fc\u526f\u7523\u7269\u7b49\u304c\u5b58\u5728\u3059\u308b\u304b\u3069\u3046\u304bPCR\u7523\u7269\u3092\u8abf\u3079\u3001\u53cd\u5fdc\u7279\u7570\u6027\u3092\u78ba\u8a8d\u3059\u308b\u305f\u3081\u306e\u3001\u7c21\u4fbf\u3067\u660e\u77ad\u306a\u65b9\u6cd5\u3067\u3059\u3002\u4eca\u56de\u306f\u3001\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u3092\u5229\u7528\u3057\u305f\u89e3\u96e2\u66f2\u7dda\u89e3\u6790\u306e\u6982\u8981\u3068\u89e3\u6790\u65b9\u6cd5\u306b\u3064\u3044\u3066\u3054\u7d39\u4ecb\u3057\u307e\u3059\u3002<\/p>\n","protected":false},"author":988,"featured_media":3235,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_monsterinsights_skip_tracking":false,"_genesis_hide_title":false,"_genesis_hide_breadcrumbs":false,"_genesis_hide_singular_image":false,"_genesis_hide_footer_widgets":false,"_genesis_custom_body_class":"","_genesis_custom_post_class":"","_genesis_layout":"","_jetpack_newsletter_access":"","_jetpack_dont_email_post_to_subs":false,"_jetpack_newsletter_tier_id":0,"_jetpack_memberships_contains_paywalled_content":false,"_jetpack_feature_clip_id":0,"_jetpack_memberships_contains_paid_content":false,"footnotes":"","jetpack_post_was_ever_published":false},"categories":[156],"tags":[7],"division":[],"class_list":["post-681","post","type-post","status-publish","format-standard","has-post-thumbnail","category-mol-bio","tag-qpcr","entry"],"_selected_authors":"","_selected_reviewers":"","acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v27.8 (Yoast SEO v27.8) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>\u7570\u306a\u308bPCR\u7523\u7269\u3092\u8b58\u5225\u3067\u304d\u308b\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u306e\u89e3\u96e2\u66f2\u7dda\u89e3\u6790\u3068\u306f\uff1f - Learning at the Bench<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/qpcr-basic39\/\" \/>\n<meta property=\"og:locale\" content=\"ja_JP\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"\u7570\u306a\u308bPCR\u7523\u7269\u3092\u8b58\u5225\u3067\u304d\u308b\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u306e\u89e3\u96e2\u66f2\u7dda\u89e3\u6790\u3068\u306f\uff1f\" \/>\n<meta property=\"og:description\" content=\"\u89e3\u96e2\u66f2\u7dda\u89e3\u6790\u306f\u3001\u30d7\u30e9\u30a4\u30de\u30fc\u30c0\u30a4\u30de\u30fc\u526f\u7523\u7269\u7b49\u304c\u5b58\u5728\u3059\u308b\u304b\u3069\u3046\u304bPCR\u7523\u7269\u3092\u8abf\u3079\u3001\u53cd\u5fdc\u7279\u7570\u6027\u3092\u78ba\u8a8d\u3059\u308b\u305f\u3081\u306e\u3001\u7c21\u4fbf\u3067\u660e\u77ad\u306a\u65b9\u6cd5\u3067\u3059\u3002\u4eca\u56de\u306f\u3001\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u3092\u5229\u7528\u3057\u305f\u89e3\u96e2\u66f2\u7dda\u89e3\u6790\u306e\u6982\u8981\u3068\u89e3\u6790\u65b9\u6cd5\u306b\u3064\u3044\u3066\u3054\u7d39\u4ecb\u3057\u307e\u3059\u3002\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/qpcr-basic39\/\" \/>\n<meta property=\"og:site_name\" content=\"Learning at the Bench\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/ThermoFisherJapan\" \/>\n<meta property=\"article:published_time\" content=\"2017-03-09T00:00:00+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2025-04-16T06:25:18+00:00\" \/>\n<meta property=\"og:image\" content=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/qpcr-basic39-title.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"1200\" \/>\n\t<meta property=\"og:image:height\" content=\"628\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"LATB Staff\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:creator\" content=\"@ThermoFisherJP\" \/>\n<meta name=\"twitter:site\" content=\"@ThermoFisherJP\" \/>\n<meta name=\"twitter:label1\" content=\"\u57f7\u7b46\u8005\" \/>\n\t<meta name=\"twitter:data1\" content=\"LATB Staff\" \/>\n\t<meta name=\"twitter:label2\" content=\"\u63a8\u5b9a\u8aad\u307f\u53d6\u308a\u6642\u9593\" \/>\n\t<meta name=\"twitter:data2\" content=\"7\u5206\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/qpcr-basic39\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/qpcr-basic39\\\/\"},\"author\":{\"name\":\"LATB Staff\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#\\\/schema\\\/person\\\/201e6a5abb838fa34e8ff0174b015d36\"},\"headline\":\"\u7570\u306a\u308bPCR\u7523\u7269\u3092\u8b58\u5225\u3067\u304d\u308b\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u306e\u89e3\u96e2\u66f2\u7dda\u89e3\u6790\u3068\u306f\uff1f\",\"datePublished\":\"2017-03-09T00:00:00+00:00\",\"dateModified\":\"2025-04-16T06:25:18+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/qpcr-basic39\\\/\"},\"wordCount\":76,\"commentCount\":0,\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/qpcr-basic39\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2019\\\/07\\\/qpcr-basic39-title.jpg\",\"keywords\":[\"\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\"],\"articleSection\":[\"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023\"],\"inLanguage\":\"ja\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/qpcr-basic39\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/qpcr-basic39\\\/\",\"url\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/qpcr-basic39\\\/\",\"name\":\"\u7570\u306a\u308bPCR\u7523\u7269\u3092\u8b58\u5225\u3067\u304d\u308b\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u306e\u89e3\u96e2\u66f2\u7dda\u89e3\u6790\u3068\u306f\uff1f - Learning at the Bench\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/qpcr-basic39\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/qpcr-basic39\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2019\\\/07\\\/qpcr-basic39-title.jpg\",\"datePublished\":\"2017-03-09T00:00:00+00:00\",\"dateModified\":\"2025-04-16T06:25:18+00:00\",\"author\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#\\\/schema\\\/person\\\/201e6a5abb838fa34e8ff0174b015d36\"},\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/qpcr-basic39\\\/#breadcrumb\"},\"inLanguage\":\"ja\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/qpcr-basic39\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"ja\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/qpcr-basic39\\\/#primaryimage\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2019\\\/07\\\/qpcr-basic39-title.jpg\",\"contentUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2019\\\/07\\\/qpcr-basic39-title.jpg\",\"width\":1200,\"height\":628},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/qpcr-basic39\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"\u7570\u306a\u308bPCR\u7523\u7269\u3092\u8b58\u5225\u3067\u304d\u308b\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u306e\u89e3\u96e2\u66f2\u7dda\u89e3\u6790\u3068\u306f\uff1f\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#website\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/\",\"name\":\"Learning at the Bench\",\"description\":\"\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"ja\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#\\\/schema\\\/person\\\/201e6a5abb838fa34e8ff0174b015d36\",\"name\":\"LATB Staff\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"ja\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/8803277856c8b753feb4217dff0f9953327452df1a615c3c88b2f9864efb2ddd?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/8803277856c8b753feb4217dff0f9953327452df1a615c3c88b2f9864efb2ddd?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/8803277856c8b753feb4217dff0f9953327452df1a615c3c88b2f9864efb2ddd?s=96&d=mm&r=g\",\"caption\":\"LATB Staff\"},\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/author\\\/latbstaff\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"\u7570\u306a\u308bPCR\u7523\u7269\u3092\u8b58\u5225\u3067\u304d\u308b\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u306e\u89e3\u96e2\u66f2\u7dda\u89e3\u6790\u3068\u306f\uff1f - Learning at the Bench","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/qpcr-basic39\/","og_locale":"ja_JP","og_type":"article","og_title":"\u7570\u306a\u308bPCR\u7523\u7269\u3092\u8b58\u5225\u3067\u304d\u308b\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u306e\u89e3\u96e2\u66f2\u7dda\u89e3\u6790\u3068\u306f\uff1f","og_description":"\u89e3\u96e2\u66f2\u7dda\u89e3\u6790\u306f\u3001\u30d7\u30e9\u30a4\u30de\u30fc\u30c0\u30a4\u30de\u30fc\u526f\u7523\u7269\u7b49\u304c\u5b58\u5728\u3059\u308b\u304b\u3069\u3046\u304bPCR\u7523\u7269\u3092\u8abf\u3079\u3001\u53cd\u5fdc\u7279\u7570\u6027\u3092\u78ba\u8a8d\u3059\u308b\u305f\u3081\u306e\u3001\u7c21\u4fbf\u3067\u660e\u77ad\u306a\u65b9\u6cd5\u3067\u3059\u3002\u4eca\u56de\u306f\u3001\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u3092\u5229\u7528\u3057\u305f\u89e3\u96e2\u66f2\u7dda\u89e3\u6790\u306e\u6982\u8981\u3068\u89e3\u6790\u65b9\u6cd5\u306b\u3064\u3044\u3066\u3054\u7d39\u4ecb\u3057\u307e\u3059\u3002","og_url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/qpcr-basic39\/","og_site_name":"Learning at the Bench","article_publisher":"https:\/\/www.facebook.com\/ThermoFisherJapan","article_published_time":"2017-03-09T00:00:00+00:00","article_modified_time":"2025-04-16T06:25:18+00:00","og_image":[{"width":1200,"height":628,"url":"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/qpcr-basic39-title.jpg","type":"image\/jpeg"}],"author":"LATB Staff","twitter_card":"summary_large_image","twitter_creator":"@ThermoFisherJP","twitter_site":"@ThermoFisherJP","twitter_misc":{"\u57f7\u7b46\u8005":"LATB Staff","\u63a8\u5b9a\u8aad\u307f\u53d6\u308a\u6642\u9593":"7\u5206"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/qpcr-basic39\/#article","isPartOf":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/qpcr-basic39\/"},"author":{"name":"LATB Staff","@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#\/schema\/person\/201e6a5abb838fa34e8ff0174b015d36"},"headline":"\u7570\u306a\u308bPCR\u7523\u7269\u3092\u8b58\u5225\u3067\u304d\u308b\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u306e\u89e3\u96e2\u66f2\u7dda\u89e3\u6790\u3068\u306f\uff1f","datePublished":"2017-03-09T00:00:00+00:00","dateModified":"2025-04-16T06:25:18+00:00","mainEntityOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/qpcr-basic39\/"},"wordCount":76,"commentCount":0,"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/qpcr-basic39\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/qpcr-basic39-title.jpg","keywords":["\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR"],"articleSection":["\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023"],"inLanguage":"ja","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/qpcr-basic39\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/qpcr-basic39\/","url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/qpcr-basic39\/","name":"\u7570\u306a\u308bPCR\u7523\u7269\u3092\u8b58\u5225\u3067\u304d\u308b\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u306e\u89e3\u96e2\u66f2\u7dda\u89e3\u6790\u3068\u306f\uff1f - Learning at the Bench","isPartOf":{"@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/qpcr-basic39\/#primaryimage"},"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/qpcr-basic39\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/qpcr-basic39-title.jpg","datePublished":"2017-03-09T00:00:00+00:00","dateModified":"2025-04-16T06:25:18+00:00","author":{"@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#\/schema\/person\/201e6a5abb838fa34e8ff0174b015d36"},"breadcrumb":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/qpcr-basic39\/#breadcrumb"},"inLanguage":"ja","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/qpcr-basic39\/"]}]},{"@type":"ImageObject","inLanguage":"ja","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/qpcr-basic39\/#primaryimage","url":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/qpcr-basic39-title.jpg","contentUrl":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/qpcr-basic39-title.jpg","width":1200,"height":628},{"@type":"BreadcrumbList","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/qpcr-basic39\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/"},{"@type":"ListItem","position":2,"name":"\u7570\u306a\u308bPCR\u7523\u7269\u3092\u8b58\u5225\u3067\u304d\u308b\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u306e\u89e3\u96e2\u66f2\u7dda\u89e3\u6790\u3068\u306f\uff1f"}]},{"@type":"WebSite","@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#website","url":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/","name":"Learning at the Bench","description":"","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"ja"},{"@type":"Person","@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#\/schema\/person\/201e6a5abb838fa34e8ff0174b015d36","name":"LATB Staff","image":{"@type":"ImageObject","inLanguage":"ja","@id":"https:\/\/secure.gravatar.com\/avatar\/8803277856c8b753feb4217dff0f9953327452df1a615c3c88b2f9864efb2ddd?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/8803277856c8b753feb4217dff0f9953327452df1a615c3c88b2f9864efb2ddd?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/8803277856c8b753feb4217dff0f9953327452df1a615c3c88b2f9864efb2ddd?s=96&d=mm&r=g","caption":"LATB Staff"},"url":"https:\/\/admin.acceleratingscience.com\/author\/latbstaff\/"}]}},"taxonomy_info":{"category":[{"value":156,"label":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023"}],"post_tag":[{"value":7,"label":"\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR"}]},"featured_image_src_large":["https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/qpcr-basic39-title-1024x536.jpg",760,398,true],"author_info":{"display_name":"LATB Staff","author_link":"https:\/\/admin.acceleratingscience.com\/author\/latbstaff\/"},"comment_info":0,"category_info":[{"term_id":156,"name":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","slug":"mol-bio","term_group":0,"term_taxonomy_id":156,"taxonomy":"category","description":"","parent":0,"count":540,"filter":"raw","meta":[],"cat_ID":156,"category_count":540,"category_description":"","cat_name":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","category_nicename":"mol-bio","category_parent":0}],"tag_info":[{"term_id":7,"name":"\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR","slug":"qpcr","term_group":0,"term_taxonomy_id":7,"taxonomy":"post_tag","description":"","parent":0,"count":91,"filter":"raw","meta":[]}],"jetpack-related-posts":[{"id":25325,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/exosome-gene-expression-ts-r-25019\/","url_meta":{"origin":681,"position":0},"title":"\u3010\u7b2c5\u56de\u3011 &#8220;RNA cargo&#8221;\u306e\u7cbe\u88fd\u3068\u5b9a\u91cf\u89e3\u6790\u300d\uff5emRNA\u306e\u5b9a\u91cf\u89e3\u6790\uff5e","author":"LatB Staff","date":"2026\u5e746\u670811\u65e5","format":false,"excerpt":"\u4eca\u56de\u306f\u3001\u30a8\u30af\u30bd\u30bd\u30fc\u30e0\uff08\u30a8\u30ad\u30bd\u30bd\u30fc\u30e0\uff09\u4e2d\u306emRNA\u306e\u5b9a\u91cf\u89e3\u6790\u306b\u3064\u3044\u3066\u8aac\u660e\u3057\u307e\u3059\u3002\u7b2c3\u56de\u3067\u30a8\u30af\u30bd\u30bd\u30fc\u30e0\u304b\u2026","rel":"","context":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","block_context":{"text":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/mol-bio\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25018_eyecatch-1.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25018_eyecatch-1.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25018_eyecatch-1.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25018_eyecatch-1.jpg?resize=700%2C400&ssl=1 2x"},"classes":[]},{"id":25247,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/exosome-gene-expression-ts-r-25018\/","url_meta":{"origin":681,"position":1},"title":"\u3010\u7b2c4\u56de\u3011&#8221;RNA cargo&#8221;\u306e\u7cbe\u88fd\u3068\u5b9a\u91cf\u89e3\u6790\uff5emiRNA\u306e\u5b9a\u91cf\u89e3\u6790\uff5e","author":"LatB Staff","date":"2026\u5e745\u670829\u65e5","format":false,"excerpt":"\u524d\u56de\uff08\u3010\u7b2c3\u56de\u3011\u201cRNA cargo\u201d\u306e\u7cbe\u88fd\u3068\u5b9a\u91cf\u89e3\u6790\uff09\u3067\u306f\u3001\u30a8\u30af\u30bd\u30bd\u30fc\u30e0 \uff08\u30a8\u30ad\u30bd\u30bd\u30fc\u30e0\uff09 \u304b\u3089\u306e\u2026","rel":"","context":"\u5206\u6790\u30fb\u6e2c\u5b9a\u95a2\u9023","block_context":{"text":"\u5206\u6790\u30fb\u6e2c\u5b9a\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/analysis\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25018_eyecatch-1.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25018_eyecatch-1.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25018_eyecatch-1.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25018_eyecatch-1.jpg?resize=700%2C400&ssl=1 2x"},"classes":[]},{"id":25565,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/exosome-antibody-ts-r-25068\/","url_meta":{"origin":681,"position":2},"title":"\u3010\u7b2c8\u56de\u3011\u30a8\u30af\u30bd\u30bd\u30fc\u30e0\u30b5\u30d6\u30bf\u30a4\u30d7\u306e\u5206\u753b\u6cd5 \uff1a \u30a6\u30a7\u30b9\u30bf\u30f3\u30d6\u30ed\u30c3\u30c8\uff0fqRT-PCR\uff0f\u30b7\u30fc\u30b1\u30f3\u30b9\u89e3\u6790\u306b\u9069\u3057\u305f\u5206\u753b\u65b9\u6cd5","author":"LatB Staff","date":"2026\u5e749\u670829\u65e5","format":false,"excerpt":"\u672c\u7a3f\u3067\u306f\u3001\u30a8\u30af\u30bd\u30bd\u30fc\u30e0\u819c\u4e0a\u306e\u7279\u5b9a\u306e\u30bf\u30f3\u30d1\u30af\u8cea\u3092\u6a19\u7684\u3068\u3057\u305f\u514d\u75ab\u5438\u7740\u6cd5\u306b\u57fa\u3065\u304f\u5206\u753b\u624b\u6cd5\u3092\u7d39\u4ecb\u3057\u307e\u3059\u3002\u30a8\u30af\u2026","rel":"","context":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","block_context":{"text":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/mol-bio\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25019_eyecatch.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25019_eyecatch.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25019_eyecatch.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25019_eyecatch.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25019_eyecatch.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25019_eyecatch.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":24545,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/digital-pcr-gene-expression-gsd-ts-sd-25082\/","url_meta":{"origin":681,"position":3},"title":"\u3010Absolute Q\u30c7\u30b8\u30bf\u30ebPCR\u30b7\u30b9\u30c6\u30e0\u306e\u6d3b\u7528\u4f8b\u3011\u30df\u30c8\u30b3\u30f3\u30c9\u30ea\u30a2DNA\u306e\u5b9a\u91cf","author":"LatB Staff","date":"2026\u5e741\u670816\u65e5","format":false,"excerpt":"Applied Biosystems\u2122 QuantStudio\u2122 Absolute Q\u2122 \u30c7\u30b8\u30bf\u30ebP\u2026","rel":"","context":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","block_context":{"text":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/mol-bio\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/12\/digital-pcr-gene-expression-gsd-ts-sd-25082_eyecatch.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/12\/digital-pcr-gene-expression-gsd-ts-sd-25082_eyecatch.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/12\/digital-pcr-gene-expression-gsd-ts-sd-25082_eyecatch.jpg?resize=525%2C300&ssl=1 1.5x"},"classes":[]},{"id":24187,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/ngs-gene-expression-csd-ts-ion-25073\/","url_meta":{"origin":681,"position":4},"title":"\u3010\u3084\u3063\u3066\u307f\u305f\u3011\u5fae\u91cf\u30fb\u5206\u89e3RNA\u306b\u3088\u308b\u767a\u73fe\u89e3\u6790\u306e\u6700\u9069\u89e3\u306f\uff1fRNA-Seq\u3068Ion AmpliSeq Transcriptome\u3092\u6bd4\u3079\u3066\u307f\u305f","author":"LatB Staff","date":"2025\u5e7411\u670828\u65e5","format":false,"excerpt":"\u6b21\u4e16\u4ee3\u30b7\u30fc\u30b1\u30f3\u30b5\u3067\u306e\u767a\u73fe\u89e3\u6790\u306b\u53d6\u308a\u7d44\u3080\u969b\u3001RNA\u30b5\u30f3\u30d7\u30eb\u304c\u300c\u5c11\u306a\u3059\u304e\u308b\u300d\u300c\u5206\u89e3\u3057\u3066\u3044\u308b\u300d\u3068\u3044\u3046\u72b6\u6cc1\u306f\u2026","rel":"","context":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","block_context":{"text":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/mol-bio\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/11\/ngs-gene-expression-csd-ts-ion-25073_eyecatch-scaled.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/11\/ngs-gene-expression-csd-ts-ion-25073_eyecatch-scaled.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/11\/ngs-gene-expression-csd-ts-ion-25073_eyecatch-scaled.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/11\/ngs-gene-expression-csd-ts-ion-25073_eyecatch-scaled.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/11\/ngs-gene-expression-csd-ts-ion-25073_eyecatch-scaled.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/11\/ngs-gene-expression-csd-ts-ion-25073_eyecatch-scaled.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":25121,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/elisa-nucleic-acid-purification-bid-ts-mbr-26017\/","url_meta":{"origin":681,"position":5},"title":"\u3044\u307e\u3055\u3089\u805e\u3051\u306a\u30444PL\u306e\u57fa\u672c\uff1a4\u30d1\u30e9\u30e1\u30fc\u30bf\u30fc\u30ed\u30b8\u30b9\u30c6\u30a3\u30c3\u30af\u3092\u308f\u304b\u308a\u3084\u3059\u304f\u89e3\u8aac","author":"LATB Staff","date":"2026\u5e745\u67087\u65e5","format":false,"excerpt":"ELISA\u306e\u691c\u91cf\u7dda\u3084\u7528\u91cf\u53cd\u5fdc\u66f2\u7dda\u3092\u4f5c\u6210\u3059\u308b\u3068\u304d\u306b\u30014\u30d1\u30e9\u30e1\u30fc\u30bf\u30fc\u30ed\u30b8\u30b9\u30c6\u30a3\u30c3\u30af\uff084PL\uff09\u30e2\u30c7\u30eb\u3092\u4f7f\u7528\u2026","rel":"","context":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","block_context":{"text":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/mol-bio\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/04\/elisa-nucleic-acid-purification-bid-ts-mbr-26017_eyecatch-1-scaled.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/04\/elisa-nucleic-acid-purification-bid-ts-mbr-26017_eyecatch-1-scaled.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/04\/elisa-nucleic-acid-purification-bid-ts-mbr-26017_eyecatch-1-scaled.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/04\/elisa-nucleic-acid-purification-bid-ts-mbr-26017_eyecatch-1-scaled.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/04\/elisa-nucleic-acid-purification-bid-ts-mbr-26017_eyecatch-1-scaled.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/04\/elisa-nucleic-acid-purification-bid-ts-mbr-26017_eyecatch-1-scaled.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]}],"jetpack_sharing_enabled":true,"amp_enabled":true,"jetpack_featured_media_url":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/qpcr-basic39-title.jpg","_links":{"self":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/posts\/681","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/users\/988"}],"replies":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/comments?post=681"}],"version-history":[{"count":0,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/posts\/681\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/media\/3235"}],"wp:attachment":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/media?parent=681"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/categories?post=681"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/tags?post=681"},{"taxonomy":"division","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/division?post=681"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}