{"id":696,"date":"2017-03-16T00:00:00","date_gmt":"2017-03-16T00:00:00","guid":{"rendered":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/qpcr-basic40\/"},"modified":"2025-04-16T15:22:54","modified_gmt":"2025-04-16T06:22:54","slug":"qpcr-basic40","status":"publish","type":"post","link":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/qpcr-basic40\/","title":{"rendered":"\u540c\u4e00\u53cd\u5fdc\u30672\u7a2e\u985e\u4ee5\u4e0a\u306e\u907a\u4f1d\u5b50\u3092\u691c\u51fa\u3059\u308b\u3001\u30de\u30eb\u30c1\u30d7\u30ec\u30c3\u30af\u30b9\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u306e\u5229\u70b9\u3068\u306f\uff1f"},"content":{"rendered":"<p>\u30de\u30eb\u30c1\u30d7\u30ec\u30c3\u30af\u30b9PCR\u306f\u3001\u540c\u4e00\u53cd\u5fdc\u306b\u304a\u3051\u308b2\u7a2e\u985e\u4ee5\u4e0a\u306e\u907a\u4f1d\u5b50\u914d\u5217\u3092\u5897\u5e45\u3057\u7279\u7570\u7684\u306b\u691c\u51fa\u3059\u308b\u65b9\u6cd5\u3067\u3059\u3002\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u30de\u30eb\u30c1\u30d7\u30ec\u30c3\u30af\u30b9\u306f\u3001\u5b9a\u6027\u307e\u305f\u306f\u5b9a\u91cf\u7684\u7d50\u679c\u3092\u5f97\u308b\u305f\u3081\u306b\u4f7f\u7528\u3055\u308c\u307e\u3059\u3002\u4eca\u56de\u306f<strong>\u30de\u30eb\u30c1\u30d7\u30ec\u30c3\u30af\u30b9\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u306e\u6982\u8981\u3068\u5229\u70b9\u306b\u3064\u3044\u3066<\/strong>\u3054\u7d39\u4ecb\u3057\u307e\u3059\u3002<\/p>\n<h2>\u30de\u30eb\u30c1\u30d7\u30ec\u30c3\u30af\u30b9\u306e\u6982\u8981<\/h2>\n<p><strong>\u30de\u30eb\u30c1\u30d7\u30ec\u30c3\u30af\u30b9PCR\u306f\u3001\u540c\u4e00\u53cd\u5fdc\u306b\u304a\u3051\u308b2\u7a2e\u985e\u4ee5\u4e0a\u306e\u907a\u4f1d\u5b50\u914d\u5217\u3092\u5897\u5e45\u3057\u7279\u7570\u7684\u306b\u691c\u51fa\u3059\u308b\u65b9\u6cd5\u3067\u3059\u3002<\/strong>\u30de\u30eb\u30c1\u30d7\u30ec\u30c3\u30af\u30b9PCR\u3092\u6210\u529f\u3055\u305b\u308b\u305f\u3081\u306b\u306f\u3001\u30b2\u30eb\u96fb\u6c17\u6cf3\u52d5\u306a\u3069\u306e\u30a8\u30f3\u30c9\u30dd\u30a4\u30f3\u30c8\u691c\u51fa\u6cd5\u306b\u3088\u3063\u3066\u76ee\u7684\u306e\u3059\u3079\u3066\u306e\u914d\u5217\u304c\u691c\u51fa\u3055\u308c\u308b\u306e\u306b\u5341\u5206\u306a\u5897\u5e45\u7523\u7269\u304c\u751f\u6210\u3055\u308c\u306a\u304f\u3066\u306f\u306a\u308a\u307e\u305b\u3093\u3002\u30de\u30eb\u30c1\u30d7\u30ec\u30c3\u30af\u30b9PCR\u306f\u3001\u5b9a\u6027\u7684\u7d50\u679c\u3092\u5f97\u308b\u305f\u3081\u306b\u4f7f\u7528\u3055\u308c\u307e\u3059\u3002<\/p>\n<p><strong>\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u30de\u30eb\u30c1\u30d7\u30ec\u30c3\u30af\u30b9\u306f\u3001\u5b9a\u6027\u307e\u305f\u306f\u5b9a\u91cf\u7684\u7d50\u679c\u3092\u5f97\u308b\u305f\u3081\u306b\u4f7f\u7528\u3055\u308c\u307e\u3059\u3002<\/strong>\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u30de\u30eb\u30c1\u30d7\u30ec\u30af\u30c3\u30af\u30b9\u3092\u6210\u529f\u3055\u305b\u308b\u305f\u3081\u306b\u306f\u3001\u76ee\u7684\u306e\u914d\u5217\u306b\u95a2\u3057\u3066\u5341\u5206\u306a\u30b7\u30b0\u30ca\u30eb\u304c\u751f\u6210\u3055\u308c\u306a\u304f\u3066\u306f\u306a\u308a\u307e\u305b\u3093\u3002<\/p>\n<p>\u300c\u30d7\u30ec\u30c3\u30af\u30b9\u300d\u3068\u3044\u3046\u8868\u73fe\u306f\u3001\u591a\u91cd\u9805\u306e\u8868\u73fe\u306b\u4f7f\u7528\u3055\u308c\u307e\u3059\u3002\u30b7\u30f3\u30b0\u30eb\u30d7\u30ec\u30c3\u30af\u30b9\u306f\u5358\u4e00\u306e\u907a\u4f1d\u5b50\u914d\u5217\u3092\u5897\u5e45\u3059\u308b\u3088\u3046\u306b\u30c7\u30b6\u30a4\u30f3\u3055\u308c\u305f\u30a2\u30c3\u30bb\u30a4\u3067\u3059\u3002\u30c7\u30e5\u30d7\u30ec\u30c3\u30af\u30b9\u306f\u30012\u500b\u306e\u907a\u4f1d\u5b50\u914d\u5217\u3092\u5897\u5e45\u3059\u308b\u3088\u3046\u306b\u30c7\u30b6\u30a4\u30f3\u3055\u308c\u305f\u30a2\u30c3\u30bb\u30a4\u3067\u3059\u3002<strong>\u6700\u3082\u4e00\u822c\u7684\u306a\u30de\u30eb\u30c1\u30d7\u30ec\u30c3\u30af\u30b9\u306f\u30c7\u30e5\u30d7\u30ec\u30c3\u30af\u30b9\u3067\u3042\u308a\u3001\u30bf\u30fc\u30b2\u30c3\u30c8\u907a\u4f1d\u5b50\u306e\u30a2\u30c3\u30bb\u30a4\u3092\u3001\u5bfe\u7167\u307e\u305f\u306f\u6a19\u6e96\u5316\u907a\u4f1d\u5b50\u3068\u540c\u4e00\u306e\u30a6\u30a7\u30eb\u3067\u884c\u308f\u308c\u307e\u3059\u3002<\/strong><\/p>\n<p>\u3044\u304f\u3064\u304b\u306e\u5e02\u8ca9\u306e\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u30ad\u30c3\u30c8\u304c\u30de\u30eb\u30c1\u30d7\u30ec\u30c3\u30af\u30b9\u7528\u306b\u30c7\u30b6\u30a4\u30f3\u3055\u308c\u691c\u8a3c\u3055\u308c\u3066\u3044\u307e\u3059\u3002\u4f8b\u3048\u3070\u3001<a href=\"https:\/\/www.thermofisher.com\/order\/catalog\/product\/4427409?CID=gsd_pcr_sbu_r04_jp_cp0000_pjt0000_gsd00000_0so_blg_op_awa_oc_s00_qpcr46_Social_LAB\" target=\"_blank\" rel=\"noopener noreferrer\">Applied Biosystems\u2122 MicroSEQ\u2122 <em>E. coli<\/em> O157:H7 Kit<\/a> \u306f\u3001\u6a19\u7684\u3068\u3059\u308b<em>E.coli<\/em>\u30a2\u30c3\u30bb\u30a4\u3092\u5185\u5728\u6027\u967d\u6027\u5bfe\u7167\u3068\u3068\u3082\u306b\u30de\u30eb\u30c1\u30d7\u30ec\u30c3\u30af\u30b9\u3057\u307e\u3059\u3002\u7814\u7a76\u306b\u5fdc\u7528\u3059\u308b\u969b\u306b\u306f\u3001\u7814\u7a76\u8005\u81ea\u8eab\u304c\u30de\u30eb\u30c1\u30d7\u30ec\u30c3\u30af\u30b9\u3059\u308b\u30a2\u30c3\u30bb\u30a4\u3092\u9078\u629e\u3057\u3001\u30de\u30eb\u30c1\u30d7\u30ec\u30c3\u30af\u30b9\u306e\u691c\u8a3c\u3082\u884c\u3046\u5fc5\u8981\u304c\u3042\u308a\u307e\u3059\u3002\u30de\u30eb\u30c1\u30d7\u30ec\u30c3\u30af\u30b9\u30a2\u30c3\u30bb\u30a4\u306e\u69cb\u7bc9\u3092\u691c\u8a0e\u3059\u308b\u5834\u5408\u306b\u306f\u3001\u30de\u30eb\u30c1\u30d7\u30ec\u30c3\u30af\u30b9\u306e\u5229\u70b9\u3068\u3001\u305d\u306e\u691c\u8a3c\u3092\u884c\u3046\u306e\u306b\u5fc5\u8981\u306a\u691c\u8a0e\u304c\u3069\u306e\u7a0b\u5ea6\u5fc5\u8981\u304b\u719f\u8003\u3059\u308b\u3053\u3068\u304c\u5fc5\u8981\u3067\u3059\u3002<\/p>\n<h2>\u30de\u30eb\u30c1\u30d7\u30ec\u30c3\u30af\u30b9\u306e\u5229\u70b9<\/h2>\n<p><strong>\u30de\u30eb\u30c1\u30d7\u30ec\u30c3\u30af\u30b9\u306e3\u3064\u306e\u5229\u70b9\u306f\u3001\u30b9\u30eb\u30fc\u30d7\u30c3\u30c8\u306e\u5897\u52a0<\/strong>\uff08\u30d7\u30ec\u30fc\u30c8\u5f53\u305f\u308a\u3088\u308a\u591a\u304f\u306e\u8a66\u6599\u304c\u30a2\u30c3\u30bb\u30a4\u53ef\u80fd\uff09\u3001<strong>\u30b5\u30f3\u30d7\u30eb\u4f7f\u7528\u91cf\u306e\u6e1b\u5c11<\/strong>\u304a\u3088\u3073<strong>\u8a66\u85ac\u4f7f\u7528\u91cf\u306e\u6e1b\u5c11<\/strong>\u3067\u3059\u3002\u3053\u308c\u3089\u306e\u30e1\u30ea\u30c3\u30c8\u306f\u5b9f\u9a13\u4e2d\u306e\u30bf\u30fc\u30b2\u30c3\u30c8\u6570\u306b\u3088\u308a\u307e\u3059\u3002\u4f8b\u3048\u3070\u3001\u5358\u4e00\u306e\u30bf\u30fc\u30b2\u30c3\u30c8\u30a2\u30c3\u30bb\u30a4\u306e\u5b9a\u91cf\u7684\u5b9f\u9a13\u306b\u304a\u3044\u3066\u306f\u3001\u30bf\u30fc\u30b2\u30c3\u30c8\u3068\u5185\u5728\u6027\u30b3\u30f3\u30c8\u30ed\u30fc\u30eb\u3068\u3068\u3082\u306b\u30c7\u30e5\u30d7\u30ec\u30c3\u30af\u30b9\u3068\u3057\u3066\u30e9\u30f3\u3067\u304d\u308b\u3053\u3068\u306b\u3088\u308a\u3001\u30b9\u30eb\u30fc\u30d7\u30c3\u30c8\u304c\u5897\u52a0\u3057\u3001\u8a66\u6599\u304a\u3088\u3073\u8a66\u85ac\u306e\u4f7f\u7528\u91cf\u30922\u500d\u6e1b\u5c11\u3055\u305b\u308b\u3053\u3068\u304c\u53ef\u80fd\u3067\u3059\u3002\u3057\u304b\u3057\u30012\u500b\u306e\u30bf\u30fc\u30b2\u30c3\u30c8\u30a2\u30c3\u30bb\u30a4\u304c\u542b\u307e\u308c\u308b\u5b9a\u91cf\u7684\u5b9f\u9a13\u306e\u5834\u5408\u306b\u306f\u3001\u3059\u3079\u3066\u306e\u30c7\u30fc\u30bf\u3092\u5f97\u308b\u305f\u3081\u306b\u3001\u30bf\u30fc\u30b2\u30c3\u30c81\u3068\u30ce\u30fc\u30de\u30e9\u30a4\u30b6\u30fc\u3001\u304a\u3088\u3073\u30bf\u30fc\u30b2\u30c3\u30c82\u3068\u30ce\u30fc\u30de\u30e9\u30a4\u30b6\u30fc\u3068\u3044\u30462\u7a2e\u985e\u306e\u30c7\u30e5\u30d7\u30ec\u30c3\u30af\u30b9\u304c\u5fc5\u8981\u3067\u3059\u3002\u3053\u306e\u5834\u5408\u3001\u30b9\u30eb\u30fc\u30d7\u30c3\u30c8\u306f\u5897\u52a0\u3057\u307e\u3059\u304c\u3001\u8a66\u6599\u304a\u3088\u3073\u8a66\u85ac\u306e\u4f7f\u7528\u91cf\u306e\u6e1b\u5c11\u306f1.5\u500d\u306b\u6291\u3048\u3089\u308c\u307e\u3059\u3002\u3053\u308c\u30893\u3064\u306e\u5229\u70b9\u306f\u3001\u5b9f\u9a13\u306b\u4f7f\u7528\u3059\u308b\u907a\u4f1d\u5b50\u914d\u5217\u306e\u6570\u306e\u95a2\u6570\u3068\u3057\u3066\u4ee5\u4e0b\u306e\u5f0f\u3067\u8868\u73fe\u3055\u308c\u307e\u3059\u3002<\/p>\n<p>\u6539\u826f\u500d\u6570 =\uff08 \u907a\u4f1d\u5b50\u6570\uff09\/ \uff08\u907a\u4f1d\u5b50\u6570 \u2013 1\uff09<\/p>\n<p><strong>\u30bf\u30fc\u30b2\u30c3\u30c8\u3068\u5185\u5728\u6027\u30b3\u30f3\u30c8\u30ed\u30fc\u30eb\u3068\u30de\u30eb\u30c1\u30d7\u30ec\u30c3\u30af\u30b9\u3059\u308b\u3082\u3046\u4e00\u3064\u306e\u5229\u70b9\u306f\u3001\u30d4\u30da\u30c3\u30c6\u30a3\u30f3\u30b0\u306e\u30a8\u30e9\u30fc\u3092\u6700\u5c0f\u5316\u3067\u304d\u308b\u3053\u3068\u3067\u3059\u3002<\/strong>\u540c\u4e00\u30a6\u30a7\u30eb\u304b\u3089\u306e\u30bf\u30fc\u30b2\u30c3\u30c8\u3068\u5185\u5728\u6027\u30b3\u30f3\u30c8\u30ed\u30fc\u30eb\u306e\u30c7\u30fc\u30bf\u306f\u3001\u540c\u4e00\u306e\u8a66\u6599\u6dfb\u52a0\u64cd\u4f5c\u306b\u7531\u6765\u3057\u3066\u3044\u308b\u305f\u3081\u3001\u30d4\u30da\u30c3\u30c6\u30a3\u30f3\u30b0\u306e\u30a8\u30e9\u30fc\u306f\u30bf\u30fc\u30b2\u30c3\u30c8\u304a\u3088\u3073\u30ce\u30fc\u30de\u30e9\u30a4\u30b6\u30fc\u306e\u7d50\u679c\u306b\u540c\u7b49\u306b\u5f71\u97ff\u3057\u3066\u3044\u308b\u3068\u8003\u3048\u3089\u308c\u307e\u3059\u3002\u3053\u306e\u5229\u70b9\u3092\u5229\u7528\u3059\u308b\u305f\u3081\u306b\u306f\u3001\u53cd\u5fa9\u7cbe\u5ea6\u3092\u8a08\u7b97\u3059\u308b\u524d\u306b\u30bf\u30fc\u30b2\u30c3\u30c8\u30c7\u30fc\u30bf\u3092\u540c\u4e00\u30a6\u30a7\u30eb\u306e\u6a19\u6e96\u5316\u30c7\u30fc\u30bf\u3067\u6a19\u6e96\u5316\u3059\u308b\u3053\u3068\u304c\u5fc5\u8981\u3067\u3059\u3002\u30b7\u30f3\u30b0\u30eb\u30d7\u30ec\u30c3\u30af\u30b9\u6cd5\u306b\u3088\u308a\u89e3\u6790\u3055\u308c\u305f\uff08\u30a6\u30a7\u30eb\u30d9\u30fc\u30b9\u306e\u6a19\u6e96\u5316\u306a\u3057\uff09\u30de\u30eb\u30c1\u30d7\u30ec\u30c3\u30af\u30b9\u30c7\u30fc\u30bf\u3068\u3001\u30de\u30eb\u30c1\u30d7\u30ec\u30c3\u30af\u30b9\u6cd5\u306b\u3088\u308a\u884c\u308f\u308c\u305f\u89e3\u6790\u3068\u306e\u6bd4\u8f03\u306b\u3088\u308a\u3001\u30b7\u30f3\u30b0\u30eb\u30d7\u30ec\u30c3\u30af\u30b9\u306e\u30a8\u30e9\u30fc\u306b\u3082\u3088\u308a\u307e\u3059\u304c\u3001\u30de\u30eb\u30c1\u30d7\u30ec\u30c3\u30af\u30b9\u7cbe\u5ea6\u306e\u5229\u70b9\u304c\u6975\u3081\u3066\u5927\u304d\u304f\u306a\u308b\u53ef\u80fd\u6027\u306e\u3042\u308b\u3053\u3068\u304c\u793a\u3055\u308c\u3066\u3044\u307e\u3059\u3002\u4f8b\u3048\u3070\u3001\u30b7\u30f3\u30b0\u30eb\u30d7\u30ec\u30c3\u30af\u30b9\u306e\u30a8\u30e9\u30fc\u304c\u6700\u5c0f\u3067\u3042\u308b\u8a66\u6599\u306b\u304a\u3044\u3066\u306f\u3001\u30de\u30eb\u30c1\u30d7\u30ec\u30c3\u30af\u30b9\u7cbe\u5ea6\u306e\u5229\u70b9\u3082\u6700\u5c0f\u3068\u306a\u308a\u307e\u3059\u3002<\/p>\n<p><strong>\u30de\u30eb\u30c1\u30d7\u30ec\u30c3\u30af\u30b9\u7cbe\u5ea6\u306e\u5229\u70b9\u306f\u3001\u3088\u308a\u9ad8\u3044\u7cbe\u5ea6\u3092\u5fc5\u8981\u3068\u3059\u308b\u5b9a\u91cf\u7684\u5b9f\u9a13\u306b\u304a\u3044\u3066\u306f\u7279\u306b\u91cd\u8981\u3067\u3059\u3002<\/strong>\u4f8b\u3048\u3070\u3001\u30b3\u30d4\u30fc\u6570\u5909\u7570\u306e\u5b9f\u9a13\u306b\u304a\u3044\u3066\u30011\u30b3\u30d4\u30fc\u306e\u907a\u4f1d\u5b50\u304b\u30892\u30b3\u30d4\u30fc\u3092\u8b58\u5225\u3059\u308b\u306e\u306f2\u500d\u306e\u5909\u5316\u3067\u3042\u308a\u3001\u826f\u597d\u306a\u7cbe\u5ea6\u304c\u5fc5\u8981\u3067\u3059\u3002\u3057\u304b\u3057\u30012\u30b3\u30d4\u30fc\u304b\u30893\u30b3\u30d4\u30fc\u3092\u8b58\u5225\u3059\u308b\u306e\u306f\u308f\u305a\u304b1.5\u500d\u306e\u5909\u5316\u3067\u3042\u308a\u3001\u3055\u3089\u306b\u512a\u308c\u305f\u7cbe\u5ea6\u304c\u8981\u6c42\u3055\u308c\u307e\u3059\u3002\u30de\u30eb\u30c1\u30d7\u30ec\u30af\u30b7\u30f3\u30b0\u306f\u3001\u3053\u306e\u3088\u3046\u306a\u30bf\u30a4\u30d7\u306e\u5b9f\u9a13\u306b\u5fc5\u8981\u3068\u3055\u308c\u308b\u7cbe\u5ea6\u3092\u5f97\u308b\u305f\u3081\u306b\u63a8\u5968\u3055\u308c\u308b\u4e00\u3064\u306e\u65b9\u6cd5\u3067\u3059\u3002<\/p>\n<h2>\u30de\u30eb\u30c1\u30d7\u30ec\u30af\u30b7\u30f3\u30b0\u7528\u88c5\u7f6e<\/h2>\n<p>\u30de\u30eb\u30c1\u30d7\u30ec\u30c3\u30af\u30b9\u30a2\u30c3\u30bb\u30a4\u3067\u306f\u901a\u5e38\u540c\u4e00\u306e\u30a6\u30a7\u30eb\u306b\u8907\u6570\u306e\u8272\u7d20\u304c\u542b\u307e\u308c\u3066\u3044\u307e\u3059\u3002\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u88c5\u7f6e\u306f\u540c\u4e00\u306e\u30a6\u30a7\u30eb\u306b\u5b58\u5728\u3059\u308b\u3053\u308c\u3089\u306e\u7570\u306a\u308b\u8272\u7d20\u3092\u6b63\u78ba\u306b\u6e2c\u5b9a\u3059\u308b\u3053\u3068\u304c\u3067\u304d\u308b\u5fc5\u8981\u304c\u3042\u308a\u307e\u3059\u3002\u4e00\u65b9\u306e\u8272\u7d20\u306e\u30b7\u30b0\u30ca\u30eb\u304c\u4ed6\u65b9\u306e\u8272\u7d20\u306e\u30b7\u30b0\u30ca\u30eb\u3068\u6bd4\u8f03\u3057\u3066\u6975\u3081\u3066\u9ad8\u3044\u5834\u5408\u306b\u304a\u3044\u3066\u3082\u3001\u5404\u8272\u7d20\u306b\u95a2\u3057\u3066\u7279\u7570\u7684\u306b\u6e2c\u5b9a\u3067\u304d\u308b\u3053\u3068\u304c\u5fc5\u8981\u3067\u3059\u3002<\/p>\n<h2>\u30de\u30eb\u30c1\u30d7\u30ec\u30af\u30b7\u30f3\u30b0\u306b\u63a8\u5968\u3055\u308c\u308b\u30b1\u30df\u30b9\u30c8\u30ea<\/h2>\n<p>\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u30de\u30eb\u30c1\u30d7\u30ec\u30af\u30b7\u30f3\u30b0\u306b\u6700\u9069\u306a\u86cd\u5149\u30b1\u30df\u30b9\u30c8\u30ea\u306f\u3001\u30de\u30eb\u30c1\u30d7\u30ec\u30c3\u30af\u30b9\u306b\u304a\u3044\u3066\u5404\u907a\u4f1d\u5b50\u914d\u5217\u3092\u691c\u51fa\u3059\u308b\u305f\u3081\u306b\u3001\u305d\u308c\u305e\u308c\u7570\u306a\u3063\u305f\u8272\u7d20\u3092\u4f7f\u7528\u3067\u304d\u308b\u3082\u306e\u3067\u3059\u3002\u307b\u3068\u3093\u3069\u306e\u30de\u30eb\u30c1\u30d7\u30ec\u30af\u30b7\u30f3\u30b0\u306f\u3001TaqMan\u30d7\u30ed\u30fc\u30d6\u30d9\u30fc\u30b9\u306e\u30a2\u30c3\u30bb\u30a4\u306b\u4ee3\u8868\u3055\u308c\u308b\u3001\u591a\u91cd\u8272\u7d20\u3001\u9ad8\u7279\u7570\u6027\u30b1\u30df\u30b9\u30c8\u30ea\u3092\u7528\u3044\u3066\u884c\u308f\u308c\u3066\u3044\u307e\u3059\u3002<\/p>\n<p><strong>RNA\u3092\u542b\u3080\u30de\u30eb\u30c1\u30d7\u30ec\u30c3\u30af\u30b9\u30a2\u30c3\u30bb\u30a4\u306b\u304a\u3044\u3066\u306f\u3001\u4e00\u822c\u7684\u306b1-Step RT-PCR\u3088\u308a\u30822-Step RT-PCR\u304c\u63a8\u5968\u3055\u308c\u307e\u3059\u3002<\/strong>1-StepRT-PCR\u3067\u306f\u3001\u9006\u8ee2\u5199\u3068PCR\u306b\u540c\u6fc3\u5ea6\u306e\u30d7\u30e9\u30a4\u30de\u30fc\u304c\u5fc5\u8981\u3068\u306a\u308a\u3001\u30de\u30eb\u30c1\u30d7\u30ec\u30af\u30b7\u30f3\u30b0\u306b\u304a\u3051\u308b\u30d7\u30e9\u30a4\u30de\u30fc\u6fc3\u5ea6\u306e\u6700\u9069\u5316\u304c\u5236\u9650\u3055\u308c\u307e\u3059\u30022-Step RT-PCR\u306b\u304a\u3044\u3066\u306f\u3001\u9006\u8ee2\u5199\u306b\u5f71\u97ff\u3092\u53ca\u307c\u3059\u3053\u3068\u306a\u304f\u3001\u30de\u30eb\u30c1\u30d7\u30ec\u30af\u30b7\u30f3\u30b0\u7528\u306b\u30d7\u30e9\u30a4\u30de\u30fc\u6fc3\u5ea6\u306e\u6700\u9069\u5316\u3092\u691c\u8a0e\u3059\u308b\u3053\u3068\u304c\u53ef\u80fd\u3067\u3059\u3002<\/p>\n<h2>\u30de\u30eb\u30c1\u30d7\u30ec\u30c3\u30af\u30b9\u53cd\u5fdc\u7528\u8272\u7d20\u306e\u9078\u629e<\/h2>\n<p><strong>\u30de\u30eb\u30c1\u30d7\u30ec\u30c3\u30af\u30b9\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u3092\u884c\u3046\u5834\u5408\u3001\u691c\u51fa\u3059\u308b\u5404\u907a\u4f1d\u5b50\u306b\u306f\u3001\u305d\u308c\u305e\u308c\u7570\u306a\u308b\u30ec\u30dd\u30fc\u30bf\u30fc\u8272\u7d20\u3092\u7528\u3044\u308b\u4e8b\u304c\u5fc5\u8981\u3067\u3059\u3002<\/strong>\u9078\u629e\u3057\u305f\u30ec\u30dd\u30fc\u30bf\u30fc\u8272\u7d20\u3092\u540c\u4e00\u306e\u30a6\u30a7\u30eb\u5185\u306b\u304a\u3044\u3066\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u88c5\u7f6e\u306b\u3088\u3063\u3066\u52b1\u8d77\u3057\u6b63\u78ba\u306b\u691c\u51fa\u3059\u308b\u3053\u3068\u304c\u5fc5\u8981\u3067\u3059\u3002\u30e1\u30fc\u30ab\u30fc\u306f\u5404\u88c5\u7f6e\u306b\u3064\u3044\u3066\u63a8\u5968\u3059\u308b\u8272\u7d20\u3092\u7d39\u4ecb\u3057\u3066\u3044\u307e\u3059\u3002Applied Biosystems\u2122 \u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u30de\u30b9\u30bf\u30fc\u30df\u30c3\u30af\u30b9\u306b\u306f\u8d64\u8272\u30d1\u30c3\u30b7\u30d6\u30ec\u30d5\u30a1\u30ec\u30f3\u30b9\u8272\u7d20\uff08ROX\u8272\u7d20\uff09\u304c\u542b\u307e\u308c\u3066\u3044\u307e\u3059\u3002\u9752\u8272\u306e\u307f\u3092\u52b1\u8d77\u3059\u308b\u88c5\u7f6e\u306f\u3001\u3053\u306eROX\u8272\u7d20\u3092\u30d1\u30c3\u30b7\u30d6\u30ec\u30d5\u30a1\u30ec\u30f3\u30b9\u8272\u7d20\u3068\u3057\u3066\u52b1\u8d77\u3055\u305b\u308b\u3053\u3068\u304c\u3067\u304d\u307e\u3059\u304c\u3001\u9752\u8272\u52b1\u8d77\u306f\u4e00\u822c\u7684\u306b\u8d64\u8272\u8272\u7d20\u3092\u30ec\u30dd\u30fc\u30bf\u30fc\u3068\u3057\u3066\u4f7f\u7528\u3059\u308b\u306b\u306f\u5341\u5206\u3067\u306f\u3042\u308a\u307e\u305b\u3093\u3002<\/p>\n<p><strong>\u30ec\u30dd\u30fc\u30bf\u30fc\u8272\u7d20\u306f\u30bf\u30fc\u30b2\u30c3\u30c8\u907a\u4f1d\u5b50\u3084\u907a\u4f1d\u5b50\u7523\u7269\u306e\u7a2e\u985e\u306b\u3088\u3063\u3066\u9078\u629e\u3059\u308b\u5fc5\u8981\u306f\u3042\u308a\u307e\u305b\u3093\u304c\u3001\u9069\u5207\u306a\u8272\u7d20\u306e\u9078\u629e\u3092\u884c\u3046\u3053\u3068\u306b\u3088\u308a\u3001\u30de\u30eb\u30c1\u30d7\u30ec\u30c3\u30af\u30b9\u30a2\u30c3\u30bb\u30a4\u3092\u7c21\u7d20\u5316\u3059\u308b\u3053\u3068\u304c\u53ef\u80fd\u3067\u3059\u3002<\/strong>\u4f8b\u3048\u3070\u3001Invitrogen\u2122 FAM\u2122 \u8272\u7d20\u306f\u3001TaqMan\u30d7\u30ed\u30fc\u30d6\u3067\u4f7f\u7528\u3055\u308c\u308b\u6700\u3082\u4e00\u822c\u7684\u306a\u30ec\u30dd\u30fc\u30bf\u30fc\u8272\u7d20\u3067\u3059\u3002\u5f53\u793e\u3067\u306f\u3001\u30bf\u30fc\u30b2\u30c3\u30c8\u30a2\u30c3\u30bb\u30a4\u7528\u306e\u30ec\u30dd\u30fc\u30bf\u30fc\u3068\u3057\u3066FAM\u8272\u7d20\u3092\u9078\u629e\u3057\u3001\u5185\u5728\u6027\u30b3\u30f3\u30c8\u30ed\u30fc\u30eb\u7528\u306e\u30ec\u30dd\u30fc\u30bf\u30fc\u3068\u3057\u3066Invitrogen\u2122 VIC\u2122 \u8272\u7d20\u3092\u9078\u629e\u3059\u308b\u3053\u3068\u3092\u304a\u52e7\u3081\u3057\u3066\u304a\u308a\u307e\u3059\u3002\u3053\u306e\u7d44\u307f\u5408\u308f\u305b\u306b\u3088\u308a\u3001FAM\u8272\u7d20\u6a19\u8b58\u3092\u3057\u305f\u8907\u6570\u306e\u30bf\u30fc\u30b2\u30c3\u30c8\u3068\u3001\u5185\u5728\u6027\u30b3\u30f3\u30c8\u30ed\u30fc\u30eb\u7528\u306e\u3001VIC \u8272\u7d20\u306e2\u7a2e\u985e\u306e\u8272\u7d20\u3092\u7d44\u307f\u5408\u308f\u305b\u305f\u30de\u30eb\u30c1\u30d7\u30ec\u30c3\u30af\u30b9\u30a2\u30c3\u30bb\u30a4\u3092\u3059\u308b\u3053\u3068\u304c\u53ef\u80fd\u3067\u3059\u3002\u30c8\u30ea\u30d7\u30ec\u30c3\u30af\u30b9\u30a2\u30c3\u30bb\u30a4\u3092\u884c\u3046\u5834\u5408\u306b\u306f\u30013\u756a\u76ee\u306e\u8272\u7d20\u3068\u3057\u3066Invitrogen\u2122 NED\u2122 \u8272\u7d20\u3092FAM\u8272\u7d20\u304a\u3088\u3073VIC \u8272\u7d20\u3068\u3068\u3082\u306b\u4f7f\u7528\u3067\u304d\u307e\u3059\u3002NED\u8272\u7d20\u3092\u4f7f\u7528\u3059\u308b\u5834\u5408\u306b\u306f\u3001\u540c\u4e00\u306e\u30a6\u30a7\u30eb\u306bTAMRA\u8272\u7d20\u304c\u5b58\u5728\u3057\u306a\u3044\u3088\u3046\u3054\u6ce8\u610f\u304f\u3060\u3055\u3044\u3002<\/p>\n<h2>\u30de\u30eb\u30c1\u30d7\u30ec\u30c3\u30af\u30b9PCR\u306b\u304a\u3051\u308b\u30d0\u30a4\u30a2\u30b9<\/h2>\n<p><strong>\u30de\u30eb\u30c1\u30d7\u30ec\u30c3\u30af\u30b9PCR\u3067\u306e\u504f\u308a\uff08\u30d0\u30a4\u30a2\u30b9\uff09\u306f\u3001\u30de\u30eb\u30c1\u30d7\u30ec\u30c3\u30af\u30b9\u30a2\u30c3\u30bb\u30a4\u306b\u304a\u3044\u3066\u8d77\u3053\u308a\u5f97\u308b\u597d\u307e\u3057\u304f\u306a\u3044\u73fe\u8c61\u3067\u3001\u30d0\u30a4\u30a2\u30b9\u304c\u304b\u304b\u308b\u3068\u3088\u308a\u591a\u304f\u5b58\u5728\u3059\u308b\u907a\u4f1d\u5b50\u304cDNA\u30dd\u30ea\u30e1\u30e9\u30fc\u30bc\u306b\u3088\u3063\u3066\u504f\u3063\u3066\u5897\u5e45\u3055\u308c\u3001\u5b58\u5728\u91cf\u306e\u5c11\u306a\u3044\u907a\u4f1d\u5b50\u306e\u5897\u5e45\u3092\u6291\u5236\u3057\u3066\u3057\u307e\u3044\u307e\u3059\u3002<\/strong>\u30d0\u30a4\u30a2\u30b9\u3078\u306e\u5bfe\u51e6\u6cd5\u306f\u3088\u308a\u591a\u304f\u5b58\u5728\u3059\u308b\u30bf\u30fc\u30b2\u30c3\u30c8\u3078\u306ePCR\u30d7\u30e9\u30a4\u30de\u30fc\u6fc3\u5ea6\u3092\u6e1b\u5c11\u3055\u305b\u308b\u3053\u3068\u3067\u3001\u300c\u30d7\u30e9\u30a4\u30de\u30fc\u30ea\u30df\u30c3\u30c8\u300d\u3068\u547c\u3070\u308c\u3066\u3044\u307e\u3059\u3002\u5236\u9650\u3092\u304b\u3051\u305f\u30d7\u30e9\u30a4\u30de\u30fc\u6fc3\u5ea6\u306f\u3001\u5c11\u306a\u304f\u3068\u3082\u6307\u6570\u95a2\u6570\u7684\u306b\u5897\u5e45\u3057\u3001\u4e14\u3064PCR\u7523\u7269\u304c\u84c4\u7a4d\u3057\u5b58\u5728\u91cf\u306e\u5c11\u306a\u3044\u30bf\u30fc\u30b2\u30c3\u30c8\u306e\u5897\u5e45\u3092\u963b\u5bb3\u3057\u3066\u3057\u307e\u3046\u524d\u306b\u30d7\u30e9\u30a4\u30de\u30fc\u304c\u67af\u6e07\u3059\u308b\u7a0b\u5ea6\u306e\u6fc3\u5ea6\u3067\u3042\u308b\u5fc5\u8981\u304c\u3042\u308a\u307e\u3059\u3002<\/p>\n<p>\u30de\u30eb\u30c1\u30d7\u30ec\u30c3\u30af\u30b9\u30a2\u30c3\u30bb\u30a4\u3092\u3059\u308b\u5834\u5408\u306b\u306f\u3001PCR\u53cd\u5fdc\u306b\u304a\u3051\u308b\u5404\u907a\u4f1d\u5b50\u3084\u907a\u4f1d\u5b50\u7523\u7269\u306e\u7d76\u5bfeDNA\u91cf\u307e\u305f\u306fcDNA\u91cf\u306b\u57fa\u3065\u3044\u3066\u3001\u3069\u306e\u907a\u4f1d\u5b50\u304c\u30d0\u30a4\u30a2\u30b9\u3092\u8d77\u3053\u3059\u53ef\u80fd\u6027\u304c\u3042\u308b\u304b\u3092\u78ba\u8a8d\u3059\u308b\u5fc5\u8981\u304c\u3042\u308a\u307e\u3059\u3002\u30c7\u30e5\u30d7\u30ec\u30c3\u30af\u30b9\u306b\u304a\u3044\u3066\u6700\u3082\u4e00\u822c\u7684\u306a3\u3064\u306e\u30b7\u30ca\u30ea\u30aa\u3092\u4ee5\u4e0b\u306b\u793a\u3057\u307e\u3059\u3002<\/p>\n<h3>\u30c7\u30e5\u30d7\u30ec\u30c3\u30af\u30b9\u30b7\u30ca\u30ea\u30aa1<\/h3>\n<p>\u3053\u308c\u304c\u6700\u3082\u4e00\u822c\u7684\u306a\u30b7\u30ca\u30ea\u30aa\u3067\u3059\u3002<strong>\u3088\u308a\u591a\u304f\u5b58\u5728\u3059\u308b\u907a\u4f1d\u5b50\u307e\u305f\u306f\u907a\u4f1d\u5b50\u7523\u7269\u304c\u3059\u3079\u3066\u306e\u30b5\u30f3\u30d7\u30eb\u306b\u304a\u3044\u3066\u540c\u4e00\u306e\u5834\u5408<\/strong>\u3002\u30d7\u30e9\u30a4\u30de\u30fc\u30ea\u30df\u30c3\u30c8\u306f\u3001\u6700\u3082\u591a\u304f\u5b58\u5728\u3059\u308b\u30bf\u30fc\u30b2\u30c3\u30c8\u306b\u5bfe\u3057\u3066\u306e\u307f\u884c\u3046\u3053\u3068\u304c\u5fc5\u8981\u3067\u3059\u3002\u4f8b\u3048\u3070\u3001\u771f\u6838\u751f\u7269\u306e\u7dcfRNA\u306e20%\u306b\u76f8\u5f53\u3059\u308b18S rRNA \u304c\u5185\u5728\u6027\u30b3\u30f3\u30c8\u30ed\u30fc\u30eb\u3067\u3042\u308b\u3068\u3057\u307e\u3059\u300218S rRNA \u7531\u6765\u306ecDNA\u306f\u3059\u3079\u3066\u306e\u30b5\u30f3\u30d7\u30eb\u306b\u304a\u3044\u3066\u3001\u3069\u306emRNA\u7531\u6765\u306ecDNA\u3088\u308a\u3082\u591a\u304f\u5b58\u5728\u3057\u307e\u3059\u3002\u3053\u306e\u305f\u3081\u300118S rRNA\u30a2\u30c3\u30bb\u30a4\u306e\u307f\u30d7\u30e9\u30a4\u30de\u30fc\u30ea\u30df\u30c3\u30c8\u3092\u884c\u3046\u3053\u3068\u304c\u5fc5\u8981\u3067\u3059\u3002<\/p>\n<h3>\u30c7\u30e5\u30d7\u30ec\u30c3\u30af\u30b9\u30b7\u30ca\u30ea\u30aa2<\/h3>\n<p><strong>2\u3064\u306e\u907a\u4f1d\u5b50\u304c\u3059\u3079\u3066\u306e\u30b5\u30f3\u30d7\u30eb\u306b\u304a\u3044\u3066\u307b\u307c\u540c\u4e00\u91cf\u5b58\u5728\u3059\u308b\u5834\u5408<\/strong>\u3002\u4e00\u822c\u7684\u306b\u3001Threshold\u304c\u540c\u3058\u3067\u3042\u308b\u3068\u4eee\u5b9a\u3057\u305f\u5834\u5408\u30012\u3064\u306e\u907a\u4f1d\u5b50\u9593\u306eCt \u306e\u5dee\u304c3\u4ee5\u4e0a\u3042\u308b\u5834\u5408\u306f\u907a\u4f1d\u5b50\u91cf\u306f\u540c\u7b49\u3068\u3044\u3048\u307e\u305b\u3093\u3002\u30b3\u30d4\u30fc\u6570\u591a\u578b\u306a\u3069\u306e\u30b2\u30ce\u30e0DNA\u89e3\u6790\u306e\u591a\u304f\u306f\u3053\u306e\u30b7\u30ca\u30ea\u30aa\u306b\u3042\u3066\u306f\u307e\u308a\u307e\u3059\u3002\u30b7\u30ca\u30ea\u30aa2\u306b\u304a\u3044\u3066\u306f2\u3064\u306e\u907a\u4f1d\u5b50\u304c\u307b\u307c\u540c\u6642\u306b\u6307\u6570\u95a2\u6570\u7684\u5897\u5e45\u30e9\u30a4\u30f3\u3092\u793a\u3059\u305f\u3081\u3001\u30d7\u30e9\u30a4\u30de\u30fc\u30ea\u30df\u30c3\u30c8\u306f\u5fc5\u8981\u3042\u308a\u307e\u305b\u3093\u3002<\/p>\n<h3>\u30c7\u30e5\u30d7\u30ec\u30c3\u30af\u30b9\u30b7\u30ca\u30ea\u30aa3<\/h3>\n<p>\u3053\u306e\u30b7\u30ca\u30ea\u30aa\u306b\u304a\u3044\u3066\u306f\u3001\u3044\u305a\u308c\u306e\u907a\u4f1d\u5b50\u304a\u3088\u3073\u907a\u4f1d\u5b50\u7523\u7269\u3082\u6975\u3081\u3066\u591a\u304f\u5b58\u5728\u3059\u308b\u53ef\u80fd\u6027\u304c\u3042\u308a\u307e\u3059\u3002\u3053\u306e\u5834\u5408\u3044\u305a\u308c\u306e\u30a2\u30c3\u30bb\u30a4\u3082\u30d7\u30e9\u30a4\u30de\u30fc\u30ea\u30df\u30c3\u30c8\u306e\u5fc5\u8981\u304c\u3042\u308a\u307e\u3059\u3002<\/p>\n<h2>\u30de\u30eb\u30c1\u30d7\u30ec\u30c3\u30af\u30b9\u30d7\u30e9\u30a4\u30de\u30fc\u76f8\u4e92\u4f5c\u7528<\/h2>\n<p><strong>\u30de\u30eb\u30c1\u30d7\u30ec\u30c3\u30af\u30b9\u30a2\u30c3\u30bb\u30a4\u306b\u95a2\u3059\u308b\u3082\u3046\u4e00\u3064\u306e\u6ce8\u610f\u70b9\u306f\u3001\u7570\u306a\u308b\u30a2\u30c3\u30bb\u30a4\u7528\u30d7\u30e9\u30a4\u30de\u30fc\u9593\u306b\u304a\u3053\u308b\u76f8\u4e92\u4f5c\u7528\u3067\u3059\u3002<\/strong>\u30de\u30eb\u30c1\u30d7\u30ec\u30c3\u30af\u30b9\u4e2d\u306e\u30a2\u30c3\u30bb\u30a4\u6570\u306e\u5897\u52a0\u306b\u3088\u308a\u30d7\u30e9\u30a4\u30de\u30fc\u30da\u30a2\u306e\u6570\u3082\u5897\u52a0\u3059\u308b\u305f\u3081\u3001\u305d\u308c\u305e\u308c\u306e\u30d7\u30e9\u30a4\u30de\u30fc\u540c\u58eb\u306e\u53cd\u5fdc\u306e\u76f8\u4e92\u4f5c\u7528\u306e\u30ea\u30b9\u30af\u3082\u5897\u5927\u3057\u307e\u3059\u3002\u4f8b\u3048\u3070\u30014\u3064\u306ePCR\u30d7\u30e9\u30a4\u30de\u30fc\u3092\u542b\u3080\u30c7\u30e5\u30d7\u30ec\u30c3\u30af\u30b9\u30a2\u30c3\u30bb\u30a4\u306b\u304a\u3044\u3066\u306f\u30016\u3064\u306e\u30d7\u30e9\u30a4\u30de\u30fc\u30da\u30a2\u304c\u751f\u3058\u308b\u53ef\u80fd\u6027\u304c\u3042\u308a\u307e\u3059\u30026\u3064\u306ePCR\u30d7\u30e9\u30a4\u30de\u30fc\u3067\u306f\u300115\u306e\u30d7\u30e9\u30a4\u30de\u30fc\u30da\u30a2\u304c\u751f\u3058\u308b\u53ef\u80fd\u6027\u304c\u3042\u308a\u307e\u3059\u3002\u5404\u30a2\u30c3\u30bb\u30a4\u306f\u3001\u30b7\u30f3\u30b0\u30eb\u30d7\u30ec\u30c3\u30af\u30b9\u306b\u304a\u3044\u3066\u306f\u826f\u597d\u306a\u6027\u80fd\u3092\u793a\u3057\u307e\u3059\u304c\u3001\u30de\u30eb\u30c1\u30d7\u30ec\u30c3\u30af\u30b9\u30a2\u30c3\u30bb\u30a4\u306b\u304a\u3044\u3066\u306f\u30d7\u30e9\u30a4\u30de\u30fc\u540c\u58eb\u306e\u76f8\u4e92\u4f5c\u7528\u304c\u7af6\u5408\u7523\u7269\u3092\u751f\u6210\u3057\u3001\u5897\u5e45\u3092\u6291\u5236\u3059\u308b\u53ef\u80fd\u6027\u304c\u3042\u308a\u307e\u3059\u3002\u30d7\u30e9\u30a4\u30de\u30fc\u540c\u58eb\u306e\u76f8\u4e92\u4f5c\u7528\u306f\u3001\u30de\u30eb\u30c1\u30d7\u30ec\u30c3\u30af\u30b9\u306b\u4f7f\u7528\u3055\u308c\u308b\u30a2\u30c3\u30bb\u30a4\u304c\u76f8\u540c\u914d\u5217\u3092\u542b\u3080\u5834\u5408\u306b\u751f\u3058\u308b\u53ef\u80fd\u6027\u304c\u3042\u308a\u307e\u3059\u3002\u30d7\u30e9\u30a4\u30de\u30fc\u76f8\u4e92\u4f5c\u7528\u304c\u8d77\u3053\u308b\u5834\u5408\u306f\u3001\u7570\u306a\u308b\u30a2\u30c3\u30bb\u30a4\u3092\u30de\u30eb\u30c1\u30d7\u30ec\u30c3\u30af\u30b9\u306b\u4f7f\u7528\u3059\u308b\u3053\u3068\u304c\u305d\u306e\u5bfe\u51e6\u6cd5\u3068\u306a\u308a\u307e\u3059\u3002<\/p>\n<p>&nbsp;<\/p>\n<h2>\u3010\u7121\u6599\u516c\u958b\u4e2d\u3011\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u30cf\u30f3\u30c9\u30d6\u30c3\u30af<\/h2>\n<p>\u3053\u306e\u30cf\u30f3\u30c9\u30d6\u30c3\u30af\u3067\u306f\u3001\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u306e\u7406\u8ad6\u3084\u5b9f\u9a13\u30c7\u30b6\u30a4\u30f3\u306e\u8a2d\u8a08\u306a\u3069\u3001\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u306e\u57fa\u790e\u77e5\u8b58\u304c\u63b2\u8f09\u3055\u308c\u3066\u3044\u307e\u3059\u3002\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u3092\u59cb\u3081\u305f\u3070\u304b\u308a\u306e\u65b9\u3084\u3053\u308c\u304b\u3089\u5b9f\u9a13\u3092\u8003\u3048\u3066\u3044\u308b\u65b9\u306b\u3046\u3063\u3066\u3064\u3051\u306e\u30cf\u30f3\u30c9\u30d6\u30c3\u30af\u3067\u3059\u3002PDF\u30d5\u30a1\u30a4\u30eb\u306e\u30c0\u30a6\u30f3\u30ed\u30fc\u30c9\u3092\u3054\u5e0c\u671b\u306e\u65b9\u306f\u3001\u4e0b\u8a18\u30dc\u30bf\u30f3\u3088\u308a\u304a\u7533\u3057\u8fbc\u307f\u304f\u3060\u3055\u3044\u3002<\/p>\n<p><a class=\"btn btn-red\" href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/global\/forms\/real-time-pcr-handbook-form.html?CID=gsd_pcr_sbu_r04_jp_cp0000_pjt0000_gsd00000_0so_blg_op_awa_oc_s00_qpcr46_Social_LAB\" target=\"_blank\" rel=\"noopener\">\u30c0\u30a6\u30f3\u30ed\u30fc\u30c9\u3059\u308b<\/a><\/p>\n<h2>\u3010\u7121\u6599\u516c\u958b\u4e2d\u3011\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u30c8\u30e9\u30d6\u30eb\u30b7\u30e5\u30fc\u30c6\u30a3\u30f3\u30b0<\/h2>\n<p>\u7570\u5e38\u306aS\u5b57\u72b6\u306e\u5897\u5e45\u66f2\u7dda\u3001NTC\u3067\u306e\u5897\u5e45\u691c\u51fa\u3001\u5897\u5e45\u304c\u898b\u3089\u308c\u306a\u3044\u306a\u3069\u3001\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u306e\u5b9f\u9a13\u4e2d\u306b\u56f0\u3063\u305f\u969b\u306e\u624b\u52a9\u3051\u306b\u306a\u308b\u60c5\u5831\u3092\u7d39\u4ecb\u3057\u3066\u3044\u307e\u3059\u3002PDF\u30d5\u30a1\u30a4\u30eb\u306e\u30c0\u30a6\u30f3\u30ed\u30fc\u30c9\u3092\u3054\u5e0c\u671b\u306e\u65b9\u306f\u3001\u4e0b\u8a18\u30dc\u30bf\u30f3\u3088\u308a\u304a\u7533\u3057\u8fbc\u307f\u304f\u3060\u3055\u3044\u3002<\/p>\n<p><a class=\"btn btn-red\" href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/global\/forms\/pcr-system-troubleshooting.html?CID=gsd_pcr_sbu_r04_jp_cp0000_pjt0000_gsd00000_0so_blg_op_awa_oc_s00_qpcr46_Social_LAB\" target=\"_blank\" rel=\"noopener\">\u30c0\u30a6\u30f3\u30ed\u30fc\u30c9\u3059\u308b<\/a><\/p>\n<p>&nbsp;<\/p>\n<p>\u7814\u7a76\u7528\u306b\u306e\u307f\u4f7f\u7528\u3067\u304d\u307e\u3059\u3002\u8a3a\u65ad\u7528\u306b\u306f\u4f7f\u7528\u3044\u305f\u3060\u3051\u307e\u305b\u3093\u3002<\/p>\n","protected":false},"excerpt":{"rendered":"<p>\u30de\u30eb\u30c1\u30d7\u30ec\u30c3\u30af\u30b9PCR\u306f\u3001\u540c\u4e00\u53cd\u5fdc\u306b\u304a\u3051\u308b2\u7a2e\u985e\u4ee5\u4e0a\u306e\u907a\u4f1d\u5b50\u914d\u5217\u3092\u5897\u5e45\u3057\u7279\u7570\u7684\u306b\u691c\u51fa\u3059\u308b\u65b9\u6cd5\u3067\u3059\u3002\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u30de\u30eb\u30c1\u30d7\u30ec\u30c3\u30af\u30b9\u306f\u3001\u5b9a\u6027\u307e\u305f\u306f\u5b9a\u91cf\u7684\u7d50\u679c\u3092\u5f97\u308b\u305f\u3081\u306b\u4f7f\u7528\u3055\u308c\u307e\u3059\u3002\u4eca\u56de\u306f\u30de\u30eb\u30c1\u30d7\u30ec\u30c3\u30af\u30b9\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u306e\u6982\u8981\u3068\u5229\u70b9\u306b\u3064\u3044\u3066\u3054\u7d39\u4ecb\u3057\u307e\u3059\u3002<\/p>\n","protected":false},"author":988,"featured_media":3260,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_monsterinsights_skip_tracking":false,"_genesis_hide_title":false,"_genesis_hide_breadcrumbs":false,"_genesis_hide_singular_image":false,"_genesis_hide_footer_widgets":false,"_genesis_custom_body_class":"","_genesis_custom_post_class":"","_genesis_layout":"","_jetpack_newsletter_access":"","_jetpack_dont_email_post_to_subs":false,"_jetpack_newsletter_tier_id":0,"_jetpack_memberships_contains_paywalled_content":false,"_jetpack_feature_clip_id":0,"_jetpack_memberships_contains_paid_content":false,"footnotes":"","jetpack_post_was_ever_published":false},"categories":[156],"tags":[7],"division":[],"class_list":["post-696","post","type-post","status-publish","format-standard","has-post-thumbnail","category-mol-bio","tag-qpcr","entry"],"_selected_authors":"","_selected_reviewers":"","acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v27.8 (Yoast SEO v27.8) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>\u540c\u4e00\u53cd\u5fdc\u30672\u7a2e\u985e\u4ee5\u4e0a\u306e\u907a\u4f1d\u5b50\u3092\u691c\u51fa\u3059\u308b\u3001\u30de\u30eb\u30c1\u30d7\u30ec\u30c3\u30af\u30b9\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u306e\u5229\u70b9\u3068\u306f\uff1f - Learning at the Bench<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/qpcr-basic40\/\" \/>\n<meta property=\"og:locale\" content=\"ja_JP\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"\u540c\u4e00\u53cd\u5fdc\u30672\u7a2e\u985e\u4ee5\u4e0a\u306e\u907a\u4f1d\u5b50\u3092\u691c\u51fa\u3059\u308b\u3001\u30de\u30eb\u30c1\u30d7\u30ec\u30c3\u30af\u30b9\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u306e\u5229\u70b9\u3068\u306f\uff1f\" \/>\n<meta property=\"og:description\" content=\"\u30de\u30eb\u30c1\u30d7\u30ec\u30c3\u30af\u30b9PCR\u306f\u3001\u540c\u4e00\u53cd\u5fdc\u306b\u304a\u3051\u308b2\u7a2e\u985e\u4ee5\u4e0a\u306e\u907a\u4f1d\u5b50\u914d\u5217\u3092\u5897\u5e45\u3057\u7279\u7570\u7684\u306b\u691c\u51fa\u3059\u308b\u65b9\u6cd5\u3067\u3059\u3002\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u30de\u30eb\u30c1\u30d7\u30ec\u30c3\u30af\u30b9\u306f\u3001\u5b9a\u6027\u307e\u305f\u306f\u5b9a\u91cf\u7684\u7d50\u679c\u3092\u5f97\u308b\u305f\u3081\u306b\u4f7f\u7528\u3055\u308c\u307e\u3059\u3002\u4eca\u56de\u306f\u30de\u30eb\u30c1\u30d7\u30ec\u30c3\u30af\u30b9\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u306e\u6982\u8981\u3068\u5229\u70b9\u306b\u3064\u3044\u3066\u3054\u7d39\u4ecb\u3057\u307e\u3059\u3002\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/qpcr-basic40\/\" \/>\n<meta property=\"og:site_name\" content=\"Learning at the Bench\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/ThermoFisherJapan\" \/>\n<meta property=\"article:published_time\" content=\"2017-03-16T00:00:00+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2025-04-16T06:22:54+00:00\" \/>\n<meta property=\"og:image\" content=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/qpcr-basic40-title.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"1200\" \/>\n\t<meta property=\"og:image:height\" content=\"628\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"LATB Staff\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:creator\" content=\"@ThermoFisherJP\" \/>\n<meta name=\"twitter:site\" content=\"@ThermoFisherJP\" \/>\n<meta name=\"twitter:label1\" content=\"\u57f7\u7b46\u8005\" \/>\n\t<meta name=\"twitter:data1\" content=\"LATB Staff\" \/>\n\t<meta name=\"twitter:label2\" content=\"\u63a8\u5b9a\u8aad\u307f\u53d6\u308a\u6642\u9593\" \/>\n\t<meta name=\"twitter:data2\" content=\"14\u5206\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/qpcr-basic40\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/qpcr-basic40\\\/\"},\"author\":{\"name\":\"LATB Staff\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#\\\/schema\\\/person\\\/201e6a5abb838fa34e8ff0174b015d36\"},\"headline\":\"\u540c\u4e00\u53cd\u5fdc\u30672\u7a2e\u985e\u4ee5\u4e0a\u306e\u907a\u4f1d\u5b50\u3092\u691c\u51fa\u3059\u308b\u3001\u30de\u30eb\u30c1\u30d7\u30ec\u30c3\u30af\u30b9\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u306e\u5229\u70b9\u3068\u306f\uff1f\",\"datePublished\":\"2017-03-16T00:00:00+00:00\",\"dateModified\":\"2025-04-16T06:22:54+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/qpcr-basic40\\\/\"},\"wordCount\":88,\"commentCount\":0,\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/qpcr-basic40\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2019\\\/07\\\/qpcr-basic40-title.jpg\",\"keywords\":[\"\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\"],\"articleSection\":[\"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023\"],\"inLanguage\":\"ja\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/qpcr-basic40\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/qpcr-basic40\\\/\",\"url\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/qpcr-basic40\\\/\",\"name\":\"\u540c\u4e00\u53cd\u5fdc\u30672\u7a2e\u985e\u4ee5\u4e0a\u306e\u907a\u4f1d\u5b50\u3092\u691c\u51fa\u3059\u308b\u3001\u30de\u30eb\u30c1\u30d7\u30ec\u30c3\u30af\u30b9\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u306e\u5229\u70b9\u3068\u306f\uff1f - Learning at the Bench\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/qpcr-basic40\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/qpcr-basic40\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2019\\\/07\\\/qpcr-basic40-title.jpg\",\"datePublished\":\"2017-03-16T00:00:00+00:00\",\"dateModified\":\"2025-04-16T06:22:54+00:00\",\"author\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#\\\/schema\\\/person\\\/201e6a5abb838fa34e8ff0174b015d36\"},\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/qpcr-basic40\\\/#breadcrumb\"},\"inLanguage\":\"ja\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/qpcr-basic40\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"ja\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/qpcr-basic40\\\/#primaryimage\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2019\\\/07\\\/qpcr-basic40-title.jpg\",\"contentUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2019\\\/07\\\/qpcr-basic40-title.jpg\",\"width\":1200,\"height\":628,\"caption\":\"qpcr-basic40-title\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/qpcr-basic40\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"\u540c\u4e00\u53cd\u5fdc\u30672\u7a2e\u985e\u4ee5\u4e0a\u306e\u907a\u4f1d\u5b50\u3092\u691c\u51fa\u3059\u308b\u3001\u30de\u30eb\u30c1\u30d7\u30ec\u30c3\u30af\u30b9\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u306e\u5229\u70b9\u3068\u306f\uff1f\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#website\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/\",\"name\":\"Learning at the Bench\",\"description\":\"\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"ja\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#\\\/schema\\\/person\\\/201e6a5abb838fa34e8ff0174b015d36\",\"name\":\"LATB Staff\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"ja\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/8803277856c8b753feb4217dff0f9953327452df1a615c3c88b2f9864efb2ddd?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/8803277856c8b753feb4217dff0f9953327452df1a615c3c88b2f9864efb2ddd?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/8803277856c8b753feb4217dff0f9953327452df1a615c3c88b2f9864efb2ddd?s=96&d=mm&r=g\",\"caption\":\"LATB Staff\"},\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/author\\\/latbstaff\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"\u540c\u4e00\u53cd\u5fdc\u30672\u7a2e\u985e\u4ee5\u4e0a\u306e\u907a\u4f1d\u5b50\u3092\u691c\u51fa\u3059\u308b\u3001\u30de\u30eb\u30c1\u30d7\u30ec\u30c3\u30af\u30b9\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u306e\u5229\u70b9\u3068\u306f\uff1f - Learning at the Bench","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/qpcr-basic40\/","og_locale":"ja_JP","og_type":"article","og_title":"\u540c\u4e00\u53cd\u5fdc\u30672\u7a2e\u985e\u4ee5\u4e0a\u306e\u907a\u4f1d\u5b50\u3092\u691c\u51fa\u3059\u308b\u3001\u30de\u30eb\u30c1\u30d7\u30ec\u30c3\u30af\u30b9\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u306e\u5229\u70b9\u3068\u306f\uff1f","og_description":"\u30de\u30eb\u30c1\u30d7\u30ec\u30c3\u30af\u30b9PCR\u306f\u3001\u540c\u4e00\u53cd\u5fdc\u306b\u304a\u3051\u308b2\u7a2e\u985e\u4ee5\u4e0a\u306e\u907a\u4f1d\u5b50\u914d\u5217\u3092\u5897\u5e45\u3057\u7279\u7570\u7684\u306b\u691c\u51fa\u3059\u308b\u65b9\u6cd5\u3067\u3059\u3002\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u30de\u30eb\u30c1\u30d7\u30ec\u30c3\u30af\u30b9\u306f\u3001\u5b9a\u6027\u307e\u305f\u306f\u5b9a\u91cf\u7684\u7d50\u679c\u3092\u5f97\u308b\u305f\u3081\u306b\u4f7f\u7528\u3055\u308c\u307e\u3059\u3002\u4eca\u56de\u306f\u30de\u30eb\u30c1\u30d7\u30ec\u30c3\u30af\u30b9\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u306e\u6982\u8981\u3068\u5229\u70b9\u306b\u3064\u3044\u3066\u3054\u7d39\u4ecb\u3057\u307e\u3059\u3002","og_url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/qpcr-basic40\/","og_site_name":"Learning at the Bench","article_publisher":"https:\/\/www.facebook.com\/ThermoFisherJapan","article_published_time":"2017-03-16T00:00:00+00:00","article_modified_time":"2025-04-16T06:22:54+00:00","og_image":[{"width":1200,"height":628,"url":"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/qpcr-basic40-title.jpg","type":"image\/jpeg"}],"author":"LATB Staff","twitter_card":"summary_large_image","twitter_creator":"@ThermoFisherJP","twitter_site":"@ThermoFisherJP","twitter_misc":{"\u57f7\u7b46\u8005":"LATB Staff","\u63a8\u5b9a\u8aad\u307f\u53d6\u308a\u6642\u9593":"14\u5206"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/qpcr-basic40\/#article","isPartOf":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/qpcr-basic40\/"},"author":{"name":"LATB Staff","@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#\/schema\/person\/201e6a5abb838fa34e8ff0174b015d36"},"headline":"\u540c\u4e00\u53cd\u5fdc\u30672\u7a2e\u985e\u4ee5\u4e0a\u306e\u907a\u4f1d\u5b50\u3092\u691c\u51fa\u3059\u308b\u3001\u30de\u30eb\u30c1\u30d7\u30ec\u30c3\u30af\u30b9\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u306e\u5229\u70b9\u3068\u306f\uff1f","datePublished":"2017-03-16T00:00:00+00:00","dateModified":"2025-04-16T06:22:54+00:00","mainEntityOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/qpcr-basic40\/"},"wordCount":88,"commentCount":0,"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/qpcr-basic40\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/qpcr-basic40-title.jpg","keywords":["\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR"],"articleSection":["\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023"],"inLanguage":"ja","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/qpcr-basic40\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/qpcr-basic40\/","url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/qpcr-basic40\/","name":"\u540c\u4e00\u53cd\u5fdc\u30672\u7a2e\u985e\u4ee5\u4e0a\u306e\u907a\u4f1d\u5b50\u3092\u691c\u51fa\u3059\u308b\u3001\u30de\u30eb\u30c1\u30d7\u30ec\u30c3\u30af\u30b9\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u306e\u5229\u70b9\u3068\u306f\uff1f - Learning at the Bench","isPartOf":{"@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/qpcr-basic40\/#primaryimage"},"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/qpcr-basic40\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/qpcr-basic40-title.jpg","datePublished":"2017-03-16T00:00:00+00:00","dateModified":"2025-04-16T06:22:54+00:00","author":{"@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#\/schema\/person\/201e6a5abb838fa34e8ff0174b015d36"},"breadcrumb":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/qpcr-basic40\/#breadcrumb"},"inLanguage":"ja","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/qpcr-basic40\/"]}]},{"@type":"ImageObject","inLanguage":"ja","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/qpcr-basic40\/#primaryimage","url":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/qpcr-basic40-title.jpg","contentUrl":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/qpcr-basic40-title.jpg","width":1200,"height":628,"caption":"qpcr-basic40-title"},{"@type":"BreadcrumbList","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/qpcr-basic40\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/"},{"@type":"ListItem","position":2,"name":"\u540c\u4e00\u53cd\u5fdc\u30672\u7a2e\u985e\u4ee5\u4e0a\u306e\u907a\u4f1d\u5b50\u3092\u691c\u51fa\u3059\u308b\u3001\u30de\u30eb\u30c1\u30d7\u30ec\u30c3\u30af\u30b9\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u306e\u5229\u70b9\u3068\u306f\uff1f"}]},{"@type":"WebSite","@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#website","url":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/","name":"Learning at the Bench","description":"","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"ja"},{"@type":"Person","@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#\/schema\/person\/201e6a5abb838fa34e8ff0174b015d36","name":"LATB Staff","image":{"@type":"ImageObject","inLanguage":"ja","@id":"https:\/\/secure.gravatar.com\/avatar\/8803277856c8b753feb4217dff0f9953327452df1a615c3c88b2f9864efb2ddd?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/8803277856c8b753feb4217dff0f9953327452df1a615c3c88b2f9864efb2ddd?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/8803277856c8b753feb4217dff0f9953327452df1a615c3c88b2f9864efb2ddd?s=96&d=mm&r=g","caption":"LATB Staff"},"url":"https:\/\/admin.acceleratingscience.com\/author\/latbstaff\/"}]}},"taxonomy_info":{"category":[{"value":156,"label":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023"}],"post_tag":[{"value":7,"label":"\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR"}]},"featured_image_src_large":["https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/qpcr-basic40-title-1024x536.jpg",760,398,true],"author_info":{"display_name":"LATB Staff","author_link":"https:\/\/admin.acceleratingscience.com\/author\/latbstaff\/"},"comment_info":0,"category_info":[{"term_id":156,"name":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","slug":"mol-bio","term_group":0,"term_taxonomy_id":156,"taxonomy":"category","description":"","parent":0,"count":540,"filter":"raw","meta":[],"cat_ID":156,"category_count":540,"category_description":"","cat_name":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","category_nicename":"mol-bio","category_parent":0}],"tag_info":[{"term_id":7,"name":"\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR","slug":"qpcr","term_group":0,"term_taxonomy_id":7,"taxonomy":"post_tag","description":"","parent":0,"count":91,"filter":"raw","meta":[]}],"jetpack-related-posts":[{"id":24187,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/ngs-gene-expression-csd-ts-ion-25073\/","url_meta":{"origin":696,"position":0},"title":"\u3010\u3084\u3063\u3066\u307f\u305f\u3011\u5fae\u91cf\u30fb\u5206\u89e3RNA\u306b\u3088\u308b\u767a\u73fe\u89e3\u6790\u306e\u6700\u9069\u89e3\u306f\uff1fRNA-Seq\u3068Ion AmpliSeq Transcriptome\u3092\u6bd4\u3079\u3066\u307f\u305f","author":"LatB Staff","date":"2025\u5e7411\u670828\u65e5","format":false,"excerpt":"\u6b21\u4e16\u4ee3\u30b7\u30fc\u30b1\u30f3\u30b5\u3067\u306e\u767a\u73fe\u89e3\u6790\u306b\u53d6\u308a\u7d44\u3080\u969b\u3001RNA\u30b5\u30f3\u30d7\u30eb\u304c\u300c\u5c11\u306a\u3059\u304e\u308b\u300d\u300c\u5206\u89e3\u3057\u3066\u3044\u308b\u300d\u3068\u3044\u3046\u72b6\u6cc1\u306f\u2026","rel":"","context":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","block_context":{"text":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/mol-bio\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/11\/ngs-gene-expression-csd-ts-ion-25073_eyecatch-scaled.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/11\/ngs-gene-expression-csd-ts-ion-25073_eyecatch-scaled.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/11\/ngs-gene-expression-csd-ts-ion-25073_eyecatch-scaled.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/11\/ngs-gene-expression-csd-ts-ion-25073_eyecatch-scaled.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/11\/ngs-gene-expression-csd-ts-ion-25073_eyecatch-scaled.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/11\/ngs-gene-expression-csd-ts-ion-25073_eyecatch-scaled.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":25325,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/exosome-gene-expression-ts-r-25019\/","url_meta":{"origin":696,"position":1},"title":"\u3010\u7b2c5\u56de\u3011 &#8220;RNA cargo&#8221;\u306e\u7cbe\u88fd\u3068\u5b9a\u91cf\u89e3\u6790\u300d\uff5emRNA\u306e\u5b9a\u91cf\u89e3\u6790\uff5e","author":"LatB Staff","date":"2026\u5e746\u670811\u65e5","format":false,"excerpt":"\u4eca\u56de\u306f\u3001\u30a8\u30af\u30bd\u30bd\u30fc\u30e0\uff08\u30a8\u30ad\u30bd\u30bd\u30fc\u30e0\uff09\u4e2d\u306emRNA\u306e\u5b9a\u91cf\u89e3\u6790\u306b\u3064\u3044\u3066\u8aac\u660e\u3057\u307e\u3059\u3002\u7b2c3\u56de\u3067\u30a8\u30af\u30bd\u30bd\u30fc\u30e0\u304b\u2026","rel":"","context":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","block_context":{"text":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/mol-bio\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25018_eyecatch-1.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25018_eyecatch-1.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25018_eyecatch-1.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25018_eyecatch-1.jpg?resize=700%2C400&ssl=1 2x"},"classes":[]},{"id":25247,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/exosome-gene-expression-ts-r-25018\/","url_meta":{"origin":696,"position":2},"title":"\u3010\u7b2c4\u56de\u3011&#8221;RNA cargo&#8221;\u306e\u7cbe\u88fd\u3068\u5b9a\u91cf\u89e3\u6790\uff5emiRNA\u306e\u5b9a\u91cf\u89e3\u6790\uff5e","author":"LatB Staff","date":"2026\u5e745\u670829\u65e5","format":false,"excerpt":"\u524d\u56de\uff08\u3010\u7b2c3\u56de\u3011\u201cRNA cargo\u201d\u306e\u7cbe\u88fd\u3068\u5b9a\u91cf\u89e3\u6790\uff09\u3067\u306f\u3001\u30a8\u30af\u30bd\u30bd\u30fc\u30e0 \uff08\u30a8\u30ad\u30bd\u30bd\u30fc\u30e0\uff09 \u304b\u3089\u306e\u2026","rel":"","context":"\u5206\u6790\u30fb\u6e2c\u5b9a\u95a2\u9023","block_context":{"text":"\u5206\u6790\u30fb\u6e2c\u5b9a\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/analysis\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25018_eyecatch-1.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25018_eyecatch-1.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25018_eyecatch-1.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25018_eyecatch-1.jpg?resize=700%2C400&ssl=1 2x"},"classes":[]},{"id":25565,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/exosome-antibody-ts-r-25068\/","url_meta":{"origin":696,"position":3},"title":"\u3010\u7b2c8\u56de\u3011\u30a8\u30af\u30bd\u30bd\u30fc\u30e0\u30b5\u30d6\u30bf\u30a4\u30d7\u306e\u5206\u753b\u6cd5 \uff1a \u30a6\u30a7\u30b9\u30bf\u30f3\u30d6\u30ed\u30c3\u30c8\uff0fqRT-PCR\uff0f\u30b7\u30fc\u30b1\u30f3\u30b9\u89e3\u6790\u306b\u9069\u3057\u305f\u5206\u753b\u65b9\u6cd5","author":"LatB Staff","date":"2026\u5e749\u670829\u65e5","format":false,"excerpt":"\u672c\u7a3f\u3067\u306f\u3001\u30a8\u30af\u30bd\u30bd\u30fc\u30e0\u819c\u4e0a\u306e\u7279\u5b9a\u306e\u30bf\u30f3\u30d1\u30af\u8cea\u3092\u6a19\u7684\u3068\u3057\u305f\u514d\u75ab\u5438\u7740\u6cd5\u306b\u57fa\u3065\u304f\u5206\u753b\u624b\u6cd5\u3092\u7d39\u4ecb\u3057\u307e\u3059\u3002\u30a8\u30af\u2026","rel":"","context":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","block_context":{"text":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/mol-bio\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25019_eyecatch.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25019_eyecatch.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25019_eyecatch.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25019_eyecatch.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25019_eyecatch.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25019_eyecatch.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":23864,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/protein-expression-cloning-bid-ts-mbr-25070\/","url_meta":{"origin":696,"position":4},"title":"\u521d\u5fc3\u8005\u3067\u3082\u5b89\u5fc3\uff01\u7c21\u5358\u306b\u3067\u304d\u308b\u767a\u73fe\u30d9\u30af\u30bf\u30fc\u306e\u4f5c\u308a\u65b9\uff1a\u4eba\u5de5\u907a\u4f1d\u5b50\u5408\u6210\u30b5\u30fc\u30d3\u30b9\u306e\u5229\u7528\u6cd5","author":"LatB Staff","date":"2025\u5e7411\u670813\u65e5","format":false,"excerpt":"\u30bf\u30f3\u30d1\u30af\u8cea\u767a\u73fe\u5b9f\u9a13\u306b\u306f\u767a\u73fe\u30d9\u30af\u30bf\u30fc\u304c\u6b20\u304b\u305b\u307e\u305b\u3093\u304c\u3001\u4e00\u304b\u3089\u4f5c\u308b\u3068\u306a\u308b\u3068\u3001\u304b\u306a\u308a\u306e\u624b\u9593\u3068\u7d4c\u9a13\u304c\u5fc5\u8981\u3067\u3059\u2026","rel":"","context":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","block_context":{"text":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/mol-bio\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/10\/protein-expression-cloning-bid-ts-mbr-25070_eyecatch.png?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/10\/protein-expression-cloning-bid-ts-mbr-25070_eyecatch.png?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/10\/protein-expression-cloning-bid-ts-mbr-25070_eyecatch.png?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/10\/protein-expression-cloning-bid-ts-mbr-25070_eyecatch.png?resize=700%2C400&ssl=1 2x"},"classes":[]},{"id":24545,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/digital-pcr-gene-expression-gsd-ts-sd-25082\/","url_meta":{"origin":696,"position":5},"title":"\u3010Absolute Q\u30c7\u30b8\u30bf\u30ebPCR\u30b7\u30b9\u30c6\u30e0\u306e\u6d3b\u7528\u4f8b\u3011\u30df\u30c8\u30b3\u30f3\u30c9\u30ea\u30a2DNA\u306e\u5b9a\u91cf","author":"LatB Staff","date":"2026\u5e741\u670816\u65e5","format":false,"excerpt":"Applied Biosystems\u2122 QuantStudio\u2122 Absolute Q\u2122 \u30c7\u30b8\u30bf\u30ebP\u2026","rel":"","context":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","block_context":{"text":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/mol-bio\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/12\/digital-pcr-gene-expression-gsd-ts-sd-25082_eyecatch.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/12\/digital-pcr-gene-expression-gsd-ts-sd-25082_eyecatch.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/12\/digital-pcr-gene-expression-gsd-ts-sd-25082_eyecatch.jpg?resize=525%2C300&ssl=1 1.5x"},"classes":[]}],"jetpack_sharing_enabled":true,"amp_enabled":true,"jetpack_featured_media_url":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/qpcr-basic40-title.jpg","_links":{"self":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/posts\/696","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/users\/988"}],"replies":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/comments?post=696"}],"version-history":[{"count":0,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/posts\/696\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/media\/3260"}],"wp:attachment":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/media?parent=696"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/categories?post=696"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/tags?post=696"},{"taxonomy":"division","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/division?post=696"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}