{"id":7149,"date":"2020-06-16T15:17:20","date_gmt":"2020-06-16T06:17:20","guid":{"rendered":"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/?p=7149"},"modified":"2022-04-01T11:24:24","modified_gmt":"2022-04-01T02:24:24","slug":"targeted_panel_ngs_gsd_ts_1","status":"publish","type":"post","link":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/targeted_panel_ngs_gsd_ts_1\/","title":{"rendered":"\u30bf\u30fc\u30b2\u30c3\u30c8\u907a\u4f1d\u5b50\u30d1\u30cd\u30eb\u307e\u305f\u306f\u30a8\u30af\u30bd\u30fc\u30e0-\u907a\u4f1d\u6027\u75be\u60a3\u7814\u7a76\u306e\u305f\u3081\u306e\u9069\u5207\u306aNGS\u30a2\u30d7\u30ed\u30fc\u30c1\u306f\u3069\u3063\u3061\uff1f"},"content":{"rendered":"<p>\u25bc\u3053\u3093\u306a\u65b9\u306b\u304a\u3059\u3059\u3081\u3067\u3059\uff01<br \/>\n\u30fb\u907a\u4f1d\u6027\u75be\u60a3\u306eNGS\u7814\u7a76\u306b\u8208\u5473\u304c\u3042\u308b<br \/>\n\u30fbNGS\u306e\u7814\u7a76\u3092\u3069\u306e\u3088\u3046\u306b\u9032\u3081\u3088\u3046\u304b\u8ff7\u3063\u3066\u3044\u308b<br \/>\n\u30fb\u7814\u7a76\u306b\u30bf\u30fc\u30b2\u30c3\u30c8\u907a\u4f1d\u5b50\u30d1\u30cd\u30eb\u3092\u5c0e\u5165\u3057\u305f\u3044<\/p>\n<h2>\u6b21\u4e16\u4ee3\u30b7\u30fc\u30b1\u30f3\u30b7\u30f3\u30b0\uff08NGS\uff09\u306b\u3088\u308b\u907a\u4f1d\u6027\u75be\u60a3\u7814\u7a76<\/h2>\n<p><a href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/life-science\/sequencing\/next-generation-sequencing.html?CID=Csd_cdx_sbu_r04_jp_cp1347_pjt5611_csd00000_0so_blg_op_lgn_kt_s00_ngs16_Social_LAB\" target=\"_blank\" rel=\"noopener noreferrer\">\u6b21\u4e16\u4ee3\u30b7\u30fc\u30b1\u30f3\u30b7\u30f3\u30b0\uff08NGS\uff09<\/a>\u306f\u3001\u6570\u5341\u4e07\u304b\u3089\u6570\u5343\u4e07\u306e\u30b7\u30fc\u30b1\u30f3\u30b9\u3092\u540c\u6642\u306b\u5b9f\u884c\u3059\u308b\u3053\u3068\u306e\u3067\u304d\u308b\u30cf\u30a4\u30b9\u30eb\u30fc\u30d7\u30c3\u30c8\u306a\u89e3\u6790\u65b9\u6cd5\u3067\u3059\u3002\u5fc3\u7b4b\u75c7\u306a\u3069\u306e\u591a\u56e0\u5b50\u907a\u4f1d\u6027\u75be\u60a3\u3092\u7814\u7a76\u3057\u3066\u3044\u308b\u7814\u7a76\u8005\u306f\u3001NGS\u3092\u4f7f\u7528\u3057\u3066\u75be\u60a3\u95a2\u9023\u907a\u4f1d\u5b50\u3092\u8fc5\u901f\u304b\u3064\u52b9\u679c\u7684\u306b\u5206\u6790\u3057\u3066\u3044\u307e\u3059\u3002\u3042\u306a\u305f\u304c\u3053\u306e\u30a2\u30d7\u30ea\u30b1\u30fc\u30b7\u30e7\u30f3\u3067NGS\u306e\u4f7f\u7528\u3092\u691c\u8a0e\u3057\u3066\u3044\u308b\u5834\u5408\u3001\u304a\u305d\u3089\u304f\u300c\u30bf\u30fc\u30b2\u30c3\u30c8\u907a\u4f1d\u5b50\u30d1\u30cd\u30eb\u307e\u305f\u306f\u30a8\u30af\u30bd\u30fc\u30e0\u30b7\u30fc\u30b1\u30f3\u30b7\u30f3\u30b0\u306e\u3069\u3061\u3089\u3092\u5b9f\u884c\u3059\u308b\u3079\u304d\u304b\uff1f\u300d\u3068\u7591\u554f\u3092\u6301\u3064\u3067\u3057\u3087\u3046\u3002\u30bf\u30fc\u30b2\u30c3\u30c8\u30b7\u30fc\u30b1\u30f3\u30b7\u30f3\u30b0\u306f\u81e8\u5e8a\u7814\u7a76\u3067\u3088\u304f\u7528\u3044\u3089\u308c\u3066\u3044\u307e\u3059\u304c\u3001\u3053\u308c\u304c\u7814\u7a76\u30cb\u30fc\u30ba\u306b\u9069\u3057\u3066\u3044\u308b\u304b\u3069\u3046\u304b\u3092\u3069\u306e\u3088\u3046\u306b\u3057\u3066\u77e5\u308b\u306e\u3067\u3057\u3087\u3046\u304b\uff1f<br \/>\n<iframe loading=\"lazy\" title=\"Targeted Panels or Exome \u2013 Which is Right for Inherited Disease Research? - Seq It Out #20\" width=\"760\" height=\"428\" src=\"https:\/\/www.youtube.com\/embed\/zuWmekivQ4c?feature=oembed\" frameborder=\"0\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture\" allowfullscreen><\/iframe><\/p>\n<h2>\u30bf\u30fc\u30b2\u30c3\u30c8\u30b7\u30fc\u30b1\u30f3\u30b7\u30f3\u30b0<\/h2>\n<p>\u30bf\u30fc\u30b2\u30c3\u30c8\u30b7\u30fc\u30b1\u30f3\u30b7\u30f3\u30b0\u306b\u3064\u3044\u3066\u3001\u3082\u3046\u5c11\u3057\u8a73\u3057\u304f\u898b\u3066\u307f\u307e\u3057\u3087\u3046\u3002\u30bf\u30fc\u30b2\u30c3\u30c8\u30b7\u30fc\u30b1\u30f3\u30b7\u30f3\u30b0\u306f\u3001\u5358\u7d14\u306aPCR\u53cd\u5fdc\u3068\u907a\u4f1d\u5b50\u30d1\u30cd\u30eb\u3092\u4f7f\u7528\u3057\u3066\u3001\u7279\u5b9a\u306e\u907a\u4f1d\u5b50\u307e\u305f\u306f\u907a\u4f1d\u5b50\u9818\u57df\u3092\u9078\u629e\u7684\u306b\u5897\u5e45\u3059\u308b\u6fc3\u7e2e\u306e\u30b9\u30c6\u30c3\u30d7\u3092\u542b\u307f\u307e\u3059\u3002\u907a\u4f1d\u5b50\u30d1\u30cd\u30eb\u306f\u30aa\u30ea\u30b4\u30cc\u30af\u30ec\u30aa\u30c1\u30c9\u30d7\u30e9\u30a4\u30de\u30fc\u30da\u30a2\u306e\u30d7\u30fc\u30eb\u3067\u69cb\u6210\u3055\u308c\u3066\u3044\u307e\u3059\u3002\u5404\u30d7\u30e9\u30a4\u30de\u30fc\u30da\u30a2\u306fPCR\u306b\u3088\u308a\u7279\u5b9a\u306e\u9818\u57df\u3092\u5897\u5e45\u3059\u308b\uff08DNA\u30a2\u30f3\u30d7\u30ea\u30b3\u30f3\u306e\u30e9\u30a4\u30d6\u30e9\u30ea\u3092\u751f\u6210\u3059\u308b\uff09\u3088\u3046\u306b\u8a2d\u8a08\u3055\u308c\u3066\u3044\u3066\u3001\u30b7\u30fc\u30b1\u30f3\u30b7\u30f3\u30b0\u306e\u305f\u3081\u306e\u6e96\u5099\u304c\u6574\u3063\u3066\u3044\u307e\u3059\u30021\u3064\u306e\u30e9\u30a4\u30d6\u30e9\u30ea\u306f1\u3064\u306e\u30b5\u30f3\u30d7\u30eb\u306b\u5bfe\u5fdc\u3057\u3001\u8907\u6570\u306e\u30e9\u30a4\u30d6\u30e9\u30ea\u3092\u4e00\u7dd2\u306b\u30d7\u30fc\u30eb\u3057\u3066\u30011\u56de\u306e\u30e9\u30f3\u3067\u540c\u6642\u306b\u30b7\u30fc\u30b1\u30f3\u30b9\u51e6\u7406\u3059\u308b\u3053\u3068\u304c\u3067\u304d\u307e\u3059\u3002<\/p>\n<h2>\u9069\u5207\u306a\u30a2\u30d7\u30ed\u30fc\u30c1\u306e\u691c\u8a0e<\/h2>\n<p>\u3067\u306f\u3001\u3042\u306a\u305f\u306e\u7814\u7a76\u3078\u306e\u9069\u5207\u306a\u30a2\u30d7\u30ed\u30fc\u30c1\u3092\u6c7a\u5b9a\u3059\u308b\u969b\u306b\u8003\u616e\u3059\u3079\u304d\u30dd\u30a4\u30f3\u30c8\u306f\u4f55\u3067\u3057\u3087\u3046\u304b\uff1f\u307e\u305a\u3001NGS\u306f\u5927\u91cf\u306e\u30c7\u30fc\u30bf\u3092\u751f\u6210\u3059\u308b\u305f\u3081\u3001\u5927\u898f\u6a21\u306a\u300c\u30c7\u30fc\u30bf\u30bb\u30c3\u30c8\u306e\u7ba1\u7406\u300d\u306e\u5f71\u97ff\u3092\u8003\u616e\u3059\u308b\u3053\u3068\u304c\u91cd\u8981\u3067\u3059\u3002\u3069\u306e\u907a\u4f1d\u5b50\u3092\u63a2\u7d22\u3059\u308b\u3079\u304d\u304b\u308f\u304b\u3089\u306a\u3044\u5834\u5408\u306f\u3001\u4f55\u5343\u3082\u306e\u907a\u4f1d\u5b50\u3092\u8abf\u3079\u3066\u691c\u51fa\u3055\u308c\u305f\u5909\u7570\u3092\u7db2\u7f85\u7684\u306b\u628a\u63e1\u3059\u308b\u3053\u3068\u304c\u3067\u304d\u308b\u30a8\u30af\u30bd\u30fc\u30e0\u30b7\u30fc\u30b1\u30f3\u30b7\u30f3\u30b0\u304c\u5f79\u7acb\u3061\u307e\u3059\u3002\u305f\u3060\u3057\u3001\u3053\u308c\u306b\u3088\u308a\u5927\u91cf\u306e\u30c7\u30fc\u30bf\u304c\u4f5c\u6210\u3055\u308c\u308b\u53ef\u80fd\u6027\u304c\u3042\u308a\u307e\u3059\u3002\u75be\u60a3\u3068\u306e\u95a2\u9023\u304c\u77e5\u3089\u308c\u3066\u3044\u308b\u3001\u307e\u305f\u306f\u7591\u3044\u306e\u3042\u308b\u907a\u4f1d\u5b50\u3092\u5206\u6790\u3059\u308b\u5834\u5408\u3001\u5927\u898f\u6a21\u306a\u30c7\u30fc\u30bf\u30bb\u30c3\u30c8\u306f\u30d0\u30a4\u30aa\u30a4\u30f3\u30d5\u30a9\u30de\u30c6\u30a3\u30af\u30b9\u3092\u56f0\u96e3\u306a\u3082\u306e\u306b\u3057\u3001\u30b3\u30b9\u30c8\u3092\u8ffd\u52a0\u3057\u3066\u3082\u307b\u3068\u3093\u3069\u3001\u3082\u3057\u304f\u306f\u5168\u304f\u826f\u3044\u7d50\u679c\u3092\u5f97\u3089\u308c\u307e\u305b\u3093\u3002\u3053\u306e\u3088\u3046\u306a\u30a2\u30d7\u30ea\u30b1\u30fc\u30b7\u30e7\u30f3\u3067\u306f\u3001\u30bf\u30fc\u30b2\u30c3\u30c8\u30b7\u30fc\u30b1\u30f3\u30b7\u30f3\u30b0\u306e\u65b9\u304c\u3001\u7279\u5b9a\u306e\u907a\u4f1d\u5b50\u306b\u57fa\u3065\u3044\u305f\u3001\u3088\u308a\u5c0f\u3055\u304f\u7ba1\u7406\u3057\u3084\u3059\u3044\u30c7\u30fc\u30bf\u30bb\u30c3\u30c8\u3092\u751f\u6210\u3067\u304d\u308b\u305f\u3081\u3001\u6642\u9593\u30fb\u30b3\u30b9\u30c8\u30fb\u30c7\u30fc\u30bf\u5206\u6790\u306e\u52b4\u529b\u3092\u7bc0\u7d04\u3067\u304d\u307e\u3059\u3002<br \/>\n\u6b21\u306b\u5c0f\u3055\u306a\u30b2\u30ce\u30e0\u9818\u57df\u306b\u6ce8\u76ee\u3057\u3066\u307f\u308b\u3068\u3001\u30bf\u30fc\u30b2\u30c3\u30c8\u30b7\u30fc\u30b1\u30f3\u30b7\u30f3\u30b0\u30a2\u30d7\u30ed\u30fc\u30c1\u306e\u65b9\u304c\u306f\u308b\u304b\u306b\u6df1\u3044\u300c\u30ab\u30d0\u30ec\u30c3\u30b8\uff08\u8aad\u307f\u53d6\u308a\u6df1\u5ea6\uff09\u300d\u3092\u5b9f\u73fe\u3057\u307e\u3059\u3002\u30a8\u30af\u30bd\u30fc\u30e0\u30b7\u30fc\u30b1\u30f3\u30b7\u30f3\u30b0\u30a2\u30d7\u30ed\u30fc\u30c1\u306e100\u30ab\u30d0\u30ec\u30c3\u30b8\u306b\u5bfe\u3057\u3066\u3001\u6700\u59275,000\u30ab\u30d0\u30ec\u30c3\u30b8\u3067\u3059\u3002\u3053\u308c\u306b\u3088\u308a\u3001\u30bf\u30fc\u30b2\u30c3\u30c8\u30b7\u30fc\u30b1\u30f3\u30b7\u30f3\u30b0\u3067\u306f\u7279\u5b9a\u306e\u75be\u60a3\u306b\u95a2\u9023\u3059\u308b\u4f4e\u983b\u5ea6\u5909\u7570\u306e\u540c\u5b9a\u304c\u53ef\u80fd\u306b\u306a\u308a\u3001\u907a\u4f1d\u5b50\u306e\u30b5\u30d6\u30bb\u30c3\u30c8\u5185\u306e\u3059\u3079\u3066\u306e\u6f5c\u5728\u7684\u306a\u5909\u7570\u304c\u78ba\u5b9f\u306b\u691c\u51fa\u3055\u308c\u308b\u3088\u3046\u306b\u306a\u308a\u307e\u3059\u3002\u4e00\u65b9\u3067\u3001\u30a8\u30af\u30bd\u30fc\u30e0\u30b7\u30fc\u30b1\u30f3\u30b7\u30f3\u30b0 \u30a2\u30d7\u30ed\u30fc\u30c1\u3067\u306f\u3044\u304f\u3064\u304b\u306e\u91cd\u8981\u306a\u5909\u7570\u304c\u691c\u51fa\u3055\u308c\u306a\u3044\u5834\u5408\u304c\u3042\u308a\u307e\u3059\u3002\u305f\u3060\u3001\u75be\u60a3\u306e\u539f\u56e0\u3068\u306a\u308b\u907a\u4f1d\u5b50\u304c\u5b8c\u5168\u306b\u308f\u304b\u3063\u3066\u3044\u306a\u3044\u5834\u5408\u306f\u3001\u7279\u5b9a\u306e\u30b2\u30ce\u30e0\u9818\u57df \u3092\u898b\u843d\u3068\u3059\u30ea\u30b9\u30af\u304c\u3042\u3063\u305f\u3068\u3057\u3066\u3082\u3001\u7814\u7a76\u3092\u9032\u3081\u308b\u305f\u3081\u306b\u3053\u3061\u3089\u3092\u9078\u629e\u3059\u308b\u4fa1\u5024\u304c\u3042\u308b\u304b\u3082\u3057\u308c\u307e\u305b\u3093\u3002<br \/>\n\u3082\u30461\u3064\u306e\u91cd\u8981\u306a\u554f\u984c\u70b9 \u306f\u3001\u300c\u5b9f\u969b\u306b\u3069\u308c\u304f\u3089\u3044\u306e\u3053\u3068\u3092\u77e5\u308a\u305f\u3044\u304b\u300d\u3067\u3059\u3002\u91cd\u8981\u306a\u5909\u7570\u306b\u6ce8\u76ee\u3057\u3066\u3044\u308b\u81e8\u5e8a\u7814\u7a76\u8005\u306e\u305f\u3081\u306b\u3001\u30bf\u30fc\u30b2\u30c3\u30c8\u907a\u4f1d\u5b50\u30d1\u30cd\u30eb\u306f\u95a2\u5fc3\u306e\u3042\u308b\u30b2\u30ce\u30e0\u9818\u57df\u306e\u307f\u3092\u542b\u3081\u305f\u30ab\u30b9\u30bf\u30de\u30a4\u30ba\u304c\u53ef\u80fd\u3067\u3059\u3002\u307e\u305f\u3001\u591a\u6570\u306e\u5909\u7570\uff08\u305d\u306e\u304b\u306a\u308a\u306e\u5272\u5408\u304c\u91cd\u8981\u3067\u3042\u308b\u304b\u3069\u3046\u304b\u304c\u672a\u77e5\uff09\u3092\u751f\u6210\u3059\u308b\u30a8\u30af\u30bd\u30fc\u30e0\u30b7\u30fc\u30b1\u30f3\u30b7\u30f3\u30b0 \u3068\u306f\u7570\u306a\u308a\u3001\u30bf\u30fc\u30b2\u30c3\u30c8\u30b7\u30fc\u30b1\u30f3\u30b7\u30f3\u30b0\u306f\u305d\u306e\u3088\u3046\u306a\u5909\u7570\u306b\u51fa\u304f\u308f\u3059\u30ea\u30b9\u30af\u3092\u8efd\u6e1b\u3059\u308b\u306e\u306b\u5f79\u7acb\u3061\u307e\u3059\u3002<br \/>\n\u4ee5\u4e0a\u306e\u3088\u3046\u306b\u3001\u30c7\u30fc\u30bf\u7ba1\u7406\u306e\u52b4\u529b\u30fb\u691c\u51fa\u611f\u5ea6\u306e\u9ad8\u3055\u30fb\u91cd\u8981\u306a\u9818\u57df\u3078\u306e\u7684\u3092\u7d5e\u3063\u305f\u89e3\u6790\u3068\u3044\u3046\u70b9\u306b\u304a\u3044\u3066\u306f\u3001\u30a8\u30af\u30bd\u30fc\u30e0\u30b7\u30fc\u30b1\u30f3\u30b7\u30f3\u30b0\u3088\u308a\u3082\u30bf\u30fc\u30b2\u30c3\u30c8\u30b7\u30fc\u30b1\u30f3\u30b7\u30f3\u30b0\u304c\u512a\u308c\u3066\u3044\u307e\u3059\u3002<\/p>\n<h2>\u307e\u3068\u3081<\/h2>\n<p>Ion AmpliSeq\u2122 \u30bf\u30fc\u30b2\u30c3\u30c8NGS\u30d1\u30cd\u30eb\u306e\u8a73\u7d30\u306b\u3064\u3044\u3066\u306f\u3001<a href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/life-science\/sequencing\/next-generation-sequencing\/ion-torrent-next-generation-sequencing-workflow\/ion-torrent-next-generation-sequencing-select-targets\/ampliseq-target-selection.html?CID=Csd_cdx_sbu_r04_jp_cp1347_pjt5611_csd00000_0so_blg_op_lgn_kt_s00_ngs16_Social_LAB\" target=\"_blank\" rel=\"noopener noreferrer\">\u3053\u3061\u3089<\/a>\u3092\u3054\u89a7\u304f\u3060\u3055\u3044\u3002<\/p>\n<p>NGS\u30d1\u30cd\u30eb\u3092\u95b2\u89a7\u3057\u305f\u308a\u3001\u72ec\u81ea\u306b\u30c7\u30b6\u30a4\u30f3\u3057\u305f\u308a\u3059\u308b\u306b\u306f\u3001<a href=\"https:\/\/www.ampliseq.com\/login\/login.action\" target=\"_blank\" rel=\"noopener noreferrer\">Ion AmpliSeq Designer<\/a>\u306b\u30a2\u30af\u30bb\u30b9\u3057\u3066\u304f\u3060\u3055\u3044\u3002<\/p>\n<p><strong>\u53c2\u8003\u60c5\u5831<\/strong><br \/>\n\u30fb<a href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/life-science\/sequencing\/next-generation-sequencing\/ion-torrent-next-generation-sequencing-workflow\/ion-torrent-next-generation-sequencing-select-targets\/ampliseq-target-selection\/ion-ampliseq-on-demand-panels-targeted-sequencing.html?CID=Csd_cdx_sbu_r04_jp_cp1347_pjt5611_csd00000_0so_blg_op_lgn_kt_s00_ngs16_Social_LAB\" target=\"_blank\" rel=\"noopener noreferrer\">\u30bf\u30fc\u30b2\u30c3\u30c8\u30b7\u30fc\u30b1\u30f3\u30b7\u30f3\u30b0\u306e\u305f\u3081\u306e Ion AmpliSeq On-Demand \u30d1\u30cd\u30eb<\/a><br \/>\n\u30fb<a href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/jp-contact.html?CID=Csd_cdx_sbu_r04_jp_cp1347_pjt5611_csd00000_0so_blg_op_lgn_kt_s00_ngs16_Social_LAB\" target=\"_blank\" rel=\"noopener noreferrer\">\u88fd\u54c1\u3084\u6280\u8853\u306b\u95a2\u3059\u308b\u304a\u554f\u3044\u5408\u308f\u305b<\/a><\/p>\n<h2>\u6b21\u4e16\u4ee3\u30b7\u30fc\u30b1\u30f3\u30b5\uff08NGS\uff09\u5165\u9580<\/h2>\n<p>\u6b21\u4e16\u4ee3\u30b7\u30fc\u30b1\u30f3\u30b9\u306e\u539f\u7406\u3084\u4f55\u304c\u3067\u304d\u308b\u304b\u304c\u3088\u304f\u308f\u304b\u3089\u306a\u3044\u3001\u307e\u305f\u306f\u81ea\u5206\u306e\u7814\u7a76\u9818\u57df\u306b\u3069\u306e\u3088\u3046\u306b\u6d3b\u7528\u3067\u304d\u308b\u304b\u308f\u304b\u3089\u306a\u3044\u3068\u3044\u3046\u65b9\u5411\u3051\u306b\u3001\u6b21\u4e16\u4ee3\u30b7\u30fc\u30b1\u30f3\u30b9\u306e\u57fa\u672c\u3084\u5404\u7814\u7a76\u9818\u57df\u306b\u7279\u5316\u3057\u305f\u30a2\u30d7\u30ea\u30b1\u30fc\u30b7\u30e7\u30f3\u3092\u307e\u3068\u3081\u307e\u3057\u305f\u3002\u30ea\u30f3\u30af\u5148\u304b\u3089\u3001\u305d\u308c\u305e\u308c\u306e\u9818\u57df\u306b\u5fdc\u3058\u305f\u30da\u30fc\u30b8\u3092\u3054\u89a7\u3044\u305f\u3060\u3051\u307e\u3059\u3002<\/p>\n<p><a class=\"btn btn-red\" href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/life-science\/sequencing\/next-generation-sequencing\/ngs-basics.html?CID=Csd_cdx_sbu_r04_jp_cp1347_pjt5611_csd00000_0so_blg_op_lgn_kt_s00_ngs16_Social_LAB\" target=\"_blank\" rel=\"noopener noreferrer\">\u8a73\u7d30\u3092\u898b\u308b<\/a><\/p>\n<h2>\u6b21\u4e16\u4ee3\u30b7\u30fc\u30b1\u30f3\u30b9 \u30c7\u30fc\u30bf\u89e3\u6790\u30aa\u30f3\u30e9\u30a4\u30f3\u500b\u5225\u76f8\u8ac7<\/h2>\n<p>IonTorrent\u30e6\u30fc\u30b6\u3067\u30c7\u30fc\u30bf\u89e3\u6790\u306b\u95a2\u3059\u308b\u5177\u4f53\u7684\u306a\u8ab2\u984c\u3092\u304a\u6301\u3061\u306e\u65b9\u306b\u306f\u3001\u7121\u6599\u306e\u500b\u5225\u76f8\u8ac7\u306e\u6642\u9593\u3092\u958b\u8a2d\u3057\u3066\u3044\u307e\u3059\u3002<\/p>\n<p><a class=\"btn btn-red\" href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/technical-resources\/seminars\/ngs-data-analysis-online-consultation.html?CID=Csd_cdx_sbu_r04_jp_cp1347_pjt5611_csd00000_0so_blg_op_lgn_kt_s00_ngs16_Social_LAB\" target=\"_blank\" rel=\"noopener noreferrer\">\u8a73\u7d30\u3092\u898b\u308b<\/a><\/p>\n<p>&nbsp;<\/p>\n<p>\u7814\u7a76\u7528\u306b\u306e\u307f\u4f7f\u7528\u3067\u304d\u307e\u3059\u3002\u8a3a\u65ad\u7528\u306b\u306f\u4f7f\u7528\u3044\u305f\u3060\u3051\u307e\u305b\u3093\u3002<\/p>\n","protected":false},"excerpt":{"rendered":"<p>\u25bc\u3053\u3093\u306a\u65b9\u306b\u304a\u3059\u3059\u3081\u3067\u3059\uff01 \u30fb\u907a\u4f1d\u6027\u75be\u60a3\u306eNGS\u7814\u7a76\u306b\u8208\u5473\u304c\u3042\u308b \u30fbNGS\u306e\u7814\u7a76\u3092\u3069\u306e\u3088\u3046\u306b\u9032\u3081\u3088\u3046\u304b\u8ff7\u3063\u3066\u3044\u308b \u30fb\u7814\u7a76\u306b\u30bf\u30fc\u30b2\u30c3\u30c8\u907a\u4f1d\u5b50\u30d1\u30cd\u30eb\u3092\u5c0e\u5165\u3057\u305f\u3044 \u6b21\u4e16\u4ee3\u30b7\u30fc\u30b1\u30f3\u30b7\u30f3\u30b0\uff08NGS\uff09\u306b\u3088\u308b\u907a\u4f1d\u6027\u75be\u60a3\u7814\u7a76 \u6b21\u4e16\u4ee3\u30b7\u30fc<\/p>\n","protected":false},"author":975,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_monsterinsights_skip_tracking":false,"_genesis_hide_title":false,"_genesis_hide_breadcrumbs":false,"_genesis_hide_singular_image":false,"_genesis_hide_footer_widgets":false,"_genesis_custom_body_class":"","_genesis_custom_post_class":"","_genesis_layout":"","_jetpack_newsletter_access":"","_jetpack_dont_email_post_to_subs":false,"_jetpack_newsletter_tier_id":0,"_jetpack_memberships_contains_paywalled_content":false,"_jetpack_feature_clip_id":0,"_jetpack_memberships_contains_paid_content":false,"footnotes":"","jetpack_post_was_ever_published":false},"categories":[156],"tags":[165],"division":[],"class_list":{"0":"post-7149","1":"post","2":"type-post","3":"status-publish","4":"format-standard","6":"category-mol-bio","7":"tag-ngs","8":"entry"},"_selected_authors":"","_selected_reviewers":"","acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v27.8 (Yoast SEO v27.8) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>\u30bf\u30fc\u30b2\u30c3\u30c8\u907a\u4f1d\u5b50\u30d1\u30cd\u30eb\u307e\u305f\u306f\u30a8\u30af\u30bd\u30fc\u30e0-\u907a\u4f1d\u6027\u75be\u60a3\u7814\u7a76\u306e\u305f\u3081\u306e\u9069\u5207\u306aNGS\u30a2\u30d7\u30ed\u30fc\u30c1\u306f\u3069\u3063\u3061\uff1f - Learning at the Bench<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/targeted_panel_ngs_gsd_ts_1\/\" \/>\n<meta property=\"og:locale\" content=\"ja_JP\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"\u30bf\u30fc\u30b2\u30c3\u30c8\u907a\u4f1d\u5b50\u30d1\u30cd\u30eb\u307e\u305f\u306f\u30a8\u30af\u30bd\u30fc\u30e0-\u907a\u4f1d\u6027\u75be\u60a3\u7814\u7a76\u306e\u305f\u3081\u306e\u9069\u5207\u306aNGS\u30a2\u30d7\u30ed\u30fc\u30c1\u306f\u3069\u3063\u3061\uff1f\" \/>\n<meta property=\"og:description\" content=\"\u25bc\u3053\u3093\u306a\u65b9\u306b\u304a\u3059\u3059\u3081\u3067\u3059\uff01 \u30fb\u907a\u4f1d\u6027\u75be\u60a3\u306eNGS\u7814\u7a76\u306b\u8208\u5473\u304c\u3042\u308b \u30fbNGS\u306e\u7814\u7a76\u3092\u3069\u306e\u3088\u3046\u306b\u9032\u3081\u3088\u3046\u304b\u8ff7\u3063\u3066\u3044\u308b \u30fb\u7814\u7a76\u306b\u30bf\u30fc\u30b2\u30c3\u30c8\u907a\u4f1d\u5b50\u30d1\u30cd\u30eb\u3092\u5c0e\u5165\u3057\u305f\u3044 \u6b21\u4e16\u4ee3\u30b7\u30fc\u30b1\u30f3\u30b7\u30f3\u30b0\uff08NGS\uff09\u306b\u3088\u308b\u907a\u4f1d\u6027\u75be\u60a3\u7814\u7a76 \u6b21\u4e16\u4ee3\u30b7\u30fc\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/targeted_panel_ngs_gsd_ts_1\/\" \/>\n<meta property=\"og:site_name\" content=\"Learning at the Bench\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/ThermoFisherJapan\" \/>\n<meta property=\"article:published_time\" content=\"2020-06-16T06:17:20+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2022-04-01T02:24:24+00:00\" \/>\n<meta name=\"author\" content=\"LatB Staff\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:creator\" content=\"@ThermoFisherJP\" \/>\n<meta name=\"twitter:site\" content=\"@ThermoFisherJP\" \/>\n<meta name=\"twitter:label1\" content=\"\u57f7\u7b46\u8005\" \/>\n\t<meta name=\"twitter:data1\" content=\"LatB Staff\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/targeted_panel_ngs_gsd_ts_1\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/targeted_panel_ngs_gsd_ts_1\\\/\"},\"author\":{\"name\":\"LatB Staff\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#\\\/schema\\\/person\\\/bdbe319a2001f279ddce6ab8eaad1253\"},\"headline\":\"\u30bf\u30fc\u30b2\u30c3\u30c8\u907a\u4f1d\u5b50\u30d1\u30cd\u30eb\u307e\u305f\u306f\u30a8\u30af\u30bd\u30fc\u30e0-\u907a\u4f1d\u6027\u75be\u60a3\u7814\u7a76\u306e\u305f\u3081\u306e\u9069\u5207\u306aNGS\u30a2\u30d7\u30ed\u30fc\u30c1\u306f\u3069\u3063\u3061\uff1f\",\"datePublished\":\"2020-06-16T06:17:20+00:00\",\"dateModified\":\"2022-04-01T02:24:24+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/targeted_panel_ngs_gsd_ts_1\\\/\"},\"wordCount\":30,\"commentCount\":0,\"keywords\":[\"\u6b21\u4e16\u4ee3\u30b7\u30fc\u30b1\u30f3\u30b5\"],\"articleSection\":[\"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023\"],\"inLanguage\":\"ja\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/targeted_panel_ngs_gsd_ts_1\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/targeted_panel_ngs_gsd_ts_1\\\/\",\"url\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/targeted_panel_ngs_gsd_ts_1\\\/\",\"name\":\"\u30bf\u30fc\u30b2\u30c3\u30c8\u907a\u4f1d\u5b50\u30d1\u30cd\u30eb\u307e\u305f\u306f\u30a8\u30af\u30bd\u30fc\u30e0-\u907a\u4f1d\u6027\u75be\u60a3\u7814\u7a76\u306e\u305f\u3081\u306e\u9069\u5207\u306aNGS\u30a2\u30d7\u30ed\u30fc\u30c1\u306f\u3069\u3063\u3061\uff1f - Learning at the Bench\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#website\"},\"datePublished\":\"2020-06-16T06:17:20+00:00\",\"dateModified\":\"2022-04-01T02:24:24+00:00\",\"author\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#\\\/schema\\\/person\\\/bdbe319a2001f279ddce6ab8eaad1253\"},\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/targeted_panel_ngs_gsd_ts_1\\\/#breadcrumb\"},\"inLanguage\":\"ja\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/targeted_panel_ngs_gsd_ts_1\\\/\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/targeted_panel_ngs_gsd_ts_1\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"\u30bf\u30fc\u30b2\u30c3\u30c8\u907a\u4f1d\u5b50\u30d1\u30cd\u30eb\u307e\u305f\u306f\u30a8\u30af\u30bd\u30fc\u30e0-\u907a\u4f1d\u6027\u75be\u60a3\u7814\u7a76\u306e\u305f\u3081\u306e\u9069\u5207\u306aNGS\u30a2\u30d7\u30ed\u30fc\u30c1\u306f\u3069\u3063\u3061\uff1f\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#website\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/\",\"name\":\"Learning at the Bench\",\"description\":\"\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"ja\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#\\\/schema\\\/person\\\/bdbe319a2001f279ddce6ab8eaad1253\",\"name\":\"LatB Staff\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"ja\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g\",\"caption\":\"LatB Staff\"},\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/author\\\/lgbadmin\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"\u30bf\u30fc\u30b2\u30c3\u30c8\u907a\u4f1d\u5b50\u30d1\u30cd\u30eb\u307e\u305f\u306f\u30a8\u30af\u30bd\u30fc\u30e0-\u907a\u4f1d\u6027\u75be\u60a3\u7814\u7a76\u306e\u305f\u3081\u306e\u9069\u5207\u306aNGS\u30a2\u30d7\u30ed\u30fc\u30c1\u306f\u3069\u3063\u3061\uff1f - Learning at the Bench","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/targeted_panel_ngs_gsd_ts_1\/","og_locale":"ja_JP","og_type":"article","og_title":"\u30bf\u30fc\u30b2\u30c3\u30c8\u907a\u4f1d\u5b50\u30d1\u30cd\u30eb\u307e\u305f\u306f\u30a8\u30af\u30bd\u30fc\u30e0-\u907a\u4f1d\u6027\u75be\u60a3\u7814\u7a76\u306e\u305f\u3081\u306e\u9069\u5207\u306aNGS\u30a2\u30d7\u30ed\u30fc\u30c1\u306f\u3069\u3063\u3061\uff1f","og_description":"\u25bc\u3053\u3093\u306a\u65b9\u306b\u304a\u3059\u3059\u3081\u3067\u3059\uff01 \u30fb\u907a\u4f1d\u6027\u75be\u60a3\u306eNGS\u7814\u7a76\u306b\u8208\u5473\u304c\u3042\u308b \u30fbNGS\u306e\u7814\u7a76\u3092\u3069\u306e\u3088\u3046\u306b\u9032\u3081\u3088\u3046\u304b\u8ff7\u3063\u3066\u3044\u308b \u30fb\u7814\u7a76\u306b\u30bf\u30fc\u30b2\u30c3\u30c8\u907a\u4f1d\u5b50\u30d1\u30cd\u30eb\u3092\u5c0e\u5165\u3057\u305f\u3044 \u6b21\u4e16\u4ee3\u30b7\u30fc\u30b1\u30f3\u30b7\u30f3\u30b0\uff08NGS\uff09\u306b\u3088\u308b\u907a\u4f1d\u6027\u75be\u60a3\u7814\u7a76 \u6b21\u4e16\u4ee3\u30b7\u30fc","og_url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/targeted_panel_ngs_gsd_ts_1\/","og_site_name":"Learning at the Bench","article_publisher":"https:\/\/www.facebook.com\/ThermoFisherJapan","article_published_time":"2020-06-16T06:17:20+00:00","article_modified_time":"2022-04-01T02:24:24+00:00","author":"LatB Staff","twitter_card":"summary_large_image","twitter_creator":"@ThermoFisherJP","twitter_site":"@ThermoFisherJP","twitter_misc":{"\u57f7\u7b46\u8005":"LatB Staff"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/targeted_panel_ngs_gsd_ts_1\/#article","isPartOf":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/targeted_panel_ngs_gsd_ts_1\/"},"author":{"name":"LatB Staff","@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#\/schema\/person\/bdbe319a2001f279ddce6ab8eaad1253"},"headline":"\u30bf\u30fc\u30b2\u30c3\u30c8\u907a\u4f1d\u5b50\u30d1\u30cd\u30eb\u307e\u305f\u306f\u30a8\u30af\u30bd\u30fc\u30e0-\u907a\u4f1d\u6027\u75be\u60a3\u7814\u7a76\u306e\u305f\u3081\u306e\u9069\u5207\u306aNGS\u30a2\u30d7\u30ed\u30fc\u30c1\u306f\u3069\u3063\u3061\uff1f","datePublished":"2020-06-16T06:17:20+00:00","dateModified":"2022-04-01T02:24:24+00:00","mainEntityOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/targeted_panel_ngs_gsd_ts_1\/"},"wordCount":30,"commentCount":0,"keywords":["\u6b21\u4e16\u4ee3\u30b7\u30fc\u30b1\u30f3\u30b5"],"articleSection":["\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023"],"inLanguage":"ja","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/targeted_panel_ngs_gsd_ts_1\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/targeted_panel_ngs_gsd_ts_1\/","url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/targeted_panel_ngs_gsd_ts_1\/","name":"\u30bf\u30fc\u30b2\u30c3\u30c8\u907a\u4f1d\u5b50\u30d1\u30cd\u30eb\u307e\u305f\u306f\u30a8\u30af\u30bd\u30fc\u30e0-\u907a\u4f1d\u6027\u75be\u60a3\u7814\u7a76\u306e\u305f\u3081\u306e\u9069\u5207\u306aNGS\u30a2\u30d7\u30ed\u30fc\u30c1\u306f\u3069\u3063\u3061\uff1f - Learning at the Bench","isPartOf":{"@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#website"},"datePublished":"2020-06-16T06:17:20+00:00","dateModified":"2022-04-01T02:24:24+00:00","author":{"@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#\/schema\/person\/bdbe319a2001f279ddce6ab8eaad1253"},"breadcrumb":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/targeted_panel_ngs_gsd_ts_1\/#breadcrumb"},"inLanguage":"ja","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/targeted_panel_ngs_gsd_ts_1\/"]}]},{"@type":"BreadcrumbList","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/targeted_panel_ngs_gsd_ts_1\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/"},{"@type":"ListItem","position":2,"name":"\u30bf\u30fc\u30b2\u30c3\u30c8\u907a\u4f1d\u5b50\u30d1\u30cd\u30eb\u307e\u305f\u306f\u30a8\u30af\u30bd\u30fc\u30e0-\u907a\u4f1d\u6027\u75be\u60a3\u7814\u7a76\u306e\u305f\u3081\u306e\u9069\u5207\u306aNGS\u30a2\u30d7\u30ed\u30fc\u30c1\u306f\u3069\u3063\u3061\uff1f"}]},{"@type":"WebSite","@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#website","url":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/","name":"Learning at the Bench","description":"","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"ja"},{"@type":"Person","@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#\/schema\/person\/bdbe319a2001f279ddce6ab8eaad1253","name":"LatB Staff","image":{"@type":"ImageObject","inLanguage":"ja","@id":"https:\/\/secure.gravatar.com\/avatar\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g","caption":"LatB Staff"},"url":"https:\/\/admin.acceleratingscience.com\/author\/lgbadmin\/"}]}},"taxonomy_info":{"category":[{"value":156,"label":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023"}],"post_tag":[{"value":165,"label":"\u6b21\u4e16\u4ee3\u30b7\u30fc\u30b1\u30f3\u30b5"}]},"featured_image_src_large":false,"author_info":{"display_name":"LatB Staff","author_link":"https:\/\/admin.acceleratingscience.com\/author\/lgbadmin\/"},"comment_info":0,"category_info":[{"term_id":156,"name":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","slug":"mol-bio","term_group":0,"term_taxonomy_id":156,"taxonomy":"category","description":"","parent":0,"count":538,"filter":"raw","meta":[],"cat_ID":156,"category_count":538,"category_description":"","cat_name":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","category_nicename":"mol-bio","category_parent":0}],"tag_info":[{"term_id":165,"name":"\u6b21\u4e16\u4ee3\u30b7\u30fc\u30b1\u30f3\u30b5","slug":"ngs","term_group":0,"term_taxonomy_id":165,"taxonomy":"post_tag","description":"","parent":0,"count":71,"filter":"raw","meta":[]}],"jetpack-related-posts":[{"id":24953,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/ngs-gene-expression-csd-ts-ion-26011\/","url_meta":{"origin":7149,"position":0},"title":"\u30e9\u30a4\u30d6\u30e9\u30ea\u30fc\u8abf\u88fd\u306e\u81ea\u52d5\u5316\u3067NGS\u306e\u53ef\u80fd\u6027\u3092\u5e83\u3052\u308b\u2015Ion Chef\u30b7\u30b9\u30c6\u30e0\u304c\u5909\u3048\u308b\u7814\u7a76\u5ba4\u306e\u30ef\u30fc\u30af\u30d5\u30ed\u30fc","author":"LatB Staff","date":"2026\u5e744\u670810\u65e5","format":false,"excerpt":"\u524d\u51e6\u7406\u306e\u81ea\u52d5\u5316\u304c\u3001NGS\u306e\u65b0\u3057\u3044\u6a19\u6e96\u3092\u3064\u304f\u308b\u6b21\u4e16\u4ee3\u30b7\u30fc\u30b1\u30f3\u30b7\u30f3\u30b0\uff08NGS\uff09\u304c\u65e5\u5e38\u7684\u306a\u7814\u7a76\u30c4\u30fc\u30eb\u3068\u306a\u3063\u2026","rel":"","context":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","block_context":{"text":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/mol-bio\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/02\/ngs-gene-expression-csd-ts-ion-26011_eyecatch.jpeg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/02\/ngs-gene-expression-csd-ts-ion-26011_eyecatch.jpeg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/02\/ngs-gene-expression-csd-ts-ion-26011_eyecatch.jpeg?resize=525%2C300&ssl=1 1.5x"},"classes":[]},{"id":24187,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/ngs-gene-expression-csd-ts-ion-25073\/","url_meta":{"origin":7149,"position":1},"title":"\u3010\u3084\u3063\u3066\u307f\u305f\u3011\u5fae\u91cf\u30fb\u5206\u89e3RNA\u306b\u3088\u308b\u767a\u73fe\u89e3\u6790\u306e\u6700\u9069\u89e3\u306f\uff1fRNA-Seq\u3068Ion AmpliSeq Transcriptome\u3092\u6bd4\u3079\u3066\u307f\u305f","author":"LatB Staff","date":"2025\u5e7411\u670828\u65e5","format":false,"excerpt":"\u6b21\u4e16\u4ee3\u30b7\u30fc\u30b1\u30f3\u30b5\u3067\u306e\u767a\u73fe\u89e3\u6790\u306b\u53d6\u308a\u7d44\u3080\u969b\u3001RNA\u30b5\u30f3\u30d7\u30eb\u304c\u300c\u5c11\u306a\u3059\u304e\u308b\u300d\u300c\u5206\u89e3\u3057\u3066\u3044\u308b\u300d\u3068\u3044\u3046\u72b6\u6cc1\u306f\u2026","rel":"","context":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","block_context":{"text":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/mol-bio\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/11\/ngs-gene-expression-csd-ts-ion-25073_eyecatch-scaled.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/11\/ngs-gene-expression-csd-ts-ion-25073_eyecatch-scaled.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/11\/ngs-gene-expression-csd-ts-ion-25073_eyecatch-scaled.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/11\/ngs-gene-expression-csd-ts-ion-25073_eyecatch-scaled.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/11\/ngs-gene-expression-csd-ts-ion-25073_eyecatch-scaled.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/11\/ngs-gene-expression-csd-ts-ion-25073_eyecatch-scaled.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":24647,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/sanger-seq-mutational-analysis-gsd-ts-ce-26007\/","url_meta":{"origin":7149,"position":2},"title":"\u30de\u30a4\u30ca\u30fc\u5909\u7570\u3092\u691c\u51fa\uff01Minor Variant Finder\u30bd\u30d5\u30c8\u30a6\u30a8\u30a2","author":"LatB Staff","date":"2026\u5e742\u67089\u65e5","format":false,"excerpt":"\u30ad\u30e3\u30d4\u30e9\u30ea\u30fc\u30b7\u30fc\u30b1\u30f3\u30b5\u3067\u306f\u300125%\u7a0b\u5ea6\u306e\u5272\u5408\u306e\u5909\u7570\u3092\u691c\u51fa\u3059\u308b\u3053\u3068\u304c\u3067\u304d\u307e\u3059\u304c\u3001\u3053\u308c\u3088\u308a\u3082\u4f4e\u3044\u5272\u5408\u306e\u5909\u2026","rel":"","context":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","block_context":{"text":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/mol-bio\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/01\/sanger-seq-mutational-analysis-gsd-ts-ce-26007_eyecatch.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/01\/sanger-seq-mutational-analysis-gsd-ts-ce-26007_eyecatch.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/01\/sanger-seq-mutational-analysis-gsd-ts-ce-26007_eyecatch.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/01\/sanger-seq-mutational-analysis-gsd-ts-ce-26007_eyecatch.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/01\/sanger-seq-mutational-analysis-gsd-ts-ce-26007_eyecatch.jpg?resize=1050%2C600&ssl=1 3x"},"classes":[]},{"id":23239,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/ngs-gene-expression-csd-ts-bfx-25060\/","url_meta":{"origin":7149,"position":3},"title":"\u98df\u54c1\u958b\u767a\u306b\u304a\u3051\u308b\u83cc\u53e2\u89e3\u6790\u3068\u907a\u4f1d\u5b50\u767a\u73fe\u89e3\u6790\u306e\u6d3b\u7528","author":"LatB Staff","date":"2025\u5e7410\u67088\u65e5","format":false,"excerpt":"\u907a\u4f1d\u5b50\u95a2\u9023\u306e\u89e3\u6790\u6280\u8853\u304c\u7814\u7a76\u306e\u307f\u306a\u3089\u305a\u7523\u696d\u5206\u91ce\u3067\u6d3b\u7528\u3055\u308c\u308b\u3088\u3046\u306b\u306a\u308a\u3001\u5e74\u6708\u304c\u7d4c\u904e\u3059\u308b\u306b\u3064\u308c\u3066\u5fdc\u7528\u7bc4\u56f2\u3082\u2026","rel":"","context":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","block_context":{"text":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/mol-bio\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/09\/ngs-gene-expression-gsd-ts-tr-25060_eyecatch.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/09\/ngs-gene-expression-gsd-ts-tr-25060_eyecatch.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/09\/ngs-gene-expression-gsd-ts-tr-25060_eyecatch.jpg?resize=525%2C300&ssl=1 1.5x"},"classes":[]},{"id":24122,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/gene-therapy-purification-affinity-chromatography-bpg-25072\/","url_meta":{"origin":7149,"position":4},"title":"\u3010\u7c21\u5358\u89e3\u8aac\uff01\u3011\u907a\u4f1d\u5b50\u6cbb\u7642\u306b\u304a\u3051\u308b\u7cbe\u88fd\u30b9\u30b1\u30fc\u30eb\u30a2\u30c3\u30d7\u306e\u30dd\u30a4\u30f3\u30c8","author":"LatB Staff","date":"2025\u5e7411\u670826\u65e5","format":false,"excerpt":"\u8fd1\u5e74\u3001\u907a\u4f1d\u5b50\u6cbb\u7642\u306e\u6025\u901f\u306a\u767a\u5c55\u306b\u3088\u308a\u3001\u6cbb\u7642\u6cd5\u306e\u958b\u767a\u3068\u5b9f\u7528\u5316\u306b\u5411\u3051\u305f\u53d6\u308a\u7d44\u307f\u304c\u6d3b\u767a\u5316\u3057\u3066\u3044\u307e\u3059\u3002 \u672c\u30d6\u30ed\u2026","rel":"","context":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","block_context":{"text":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/mol-bio\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/11\/ngs-gene-expression-bpg-25072_eycatch.png?resize=350%2C200&ssl=1","width":350,"height":200},"classes":[]},{"id":20124,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/exosome-gene-therapy-ts-r-25015\/","url_meta":{"origin":7149,"position":5},"title":"\u3010\u7b2c1\u56de\u3011Exosome\uff08\u30a8\u30af\u30bd\u30bd\u30fc\u30e0\uff0f\u30a8\u30ad\u30bd\u30bd\u30fc\u30e0\uff09\u3068\u306f\uff1f","author":"LatB Staff","date":"2026\u5e744\u670815\u65e5","format":false,"excerpt":"Exosome\uff08\u30a8\u30af\u30bd\u30bd\u30fc\u30e0\uff0f\u30a8\u30ad\u30bd\u30bd\u30fc\u30e0\uff09\u306e\u7814\u7a76\u304c\u6ce8\u76ee\u3092\u96c6\u3081\u3066\u3044\u307e\u3059\u3002\u8208\u5473\u306f\u3042\u3063\u3066\u3082\u3001\u3069\u306e\u3088\u3046\u306b\u7814\u2026","rel":"","context":"\u305d\u306e\u4ed6","block_context":{"text":"\u305d\u306e\u4ed6","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/else\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/03\/6fae859c8c1eacdaa39f3ae843ae1bda-scaled.png?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/03\/6fae859c8c1eacdaa39f3ae843ae1bda-scaled.png?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/03\/6fae859c8c1eacdaa39f3ae843ae1bda-scaled.png?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/03\/6fae859c8c1eacdaa39f3ae843ae1bda-scaled.png?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/03\/6fae859c8c1eacdaa39f3ae843ae1bda-scaled.png?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/03\/6fae859c8c1eacdaa39f3ae843ae1bda-scaled.png?resize=1400%2C800&ssl=1 4x"},"classes":[]}],"jetpack_sharing_enabled":true,"amp_enabled":true,"jetpack_featured_media_url":"","_links":{"self":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/posts\/7149","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/users\/975"}],"replies":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/comments?post=7149"}],"version-history":[{"count":0,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/posts\/7149\/revisions"}],"wp:attachment":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/media?parent=7149"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/categories?post=7149"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/tags?post=7149"},{"taxonomy":"division","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/division?post=7149"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}