{"id":7161,"date":"2020-06-19T10:19:41","date_gmt":"2020-06-19T01:19:41","guid":{"rendered":"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/?p=7161"},"modified":"2021-12-02T11:05:31","modified_gmt":"2021-12-02T02:05:31","slug":"basic_ma_gsd_ts_1","status":"publish","type":"post","link":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/basic_ma_gsd_ts_1\/","title":{"rendered":"\u3010\u3084\u3063\u3066\u307f\u305f\u3011\u6d17\u6d44\u67d3\u8272\u7528\u30b7\u30b9\u30c6\u30e0\u5229\u7528\u6642\u306e\u8a66\u85ac\u3092\u7f6e\u304d\u9593\u9055\u3048\u3066\u907a\u4f1d\u5b50\u767a\u73fe\u89e3\u6790\u7528\u30a2\u30ec\u30a4\u306e\u30c7\u30fc\u30bf\u3092\u53d6\u5f97\u3057\u3066\u307f\u305f\u2015\uff11"},"content":{"rendered":"<p>\u3053\u306e\u30d6\u30ed\u30b0\u3067\u306f\u30de\u30a4\u30af\u30ed\u30a2\u30ec\u30a4\u30b7\u30b9\u30c6\u30e0GCS3000 7G System\u3092\u6700\u8fd1\u4f7f\u7528\u3057\u59cb\u3081\u305f\u3051\u308c\u3069\u3082\u3001\u307e\u3060\u6570\u56de\u3057\u304b\u4f7f\u3063\u3066\u304a\u3089\u305a\u4f7f\u3044\u6163\u308c\u3066\u3044\u306a\u3044\u65b9\u5411\u3051\u306b\u3001\u30b7\u30b9\u30c6\u30e0\u64cd\u4f5c\u3067\u3088\u304f\u3042\u308b\u30c8\u30e9\u30d6\u30eb\u4e8b\u4f8b\u3084\u5bfe\u51e6\u65b9\u6cd5\u3092\u3054\u7d39\u4ecb\u3057\u307e\u3059\uff01<\/p>\n<h2>GCS 3000 7G System\u306b\u3064\u3044\u3066<\/h2>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"size-full wp-image-7162 alignright\" src=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2020\/06\/GCS3000-7G.jpg\" alt=\"\" width=\"280\" height=\"120\" \/><\/p>\n<p>Applied Biosystems\u2122 GeneChip\u2122 Scanner 3000 7G System\u306f\u3001\u30cf\u30a4\u30d6\u30ea\u30c0\u30a4\u30bc\u30fc\u30b7\u30e7\u30f3\u304b\u3089\u6d17\u6d44\u3001\u67d3\u8272\u3001\u30b9\u30ad\u30e3\u30f3\u306b\u5fc5\u8981\u306a\u6a5f\u5668\u304c\u7d71\u5408\u3055\u308c\u305f\u30ab\u30fc\u30c8\u30ea\u30c3\u30b8\u30a2\u30ec\u30a4\u5c02\u7528\u306e\u30b7\u30b9\u30c6\u30e0\u3067\u3059\u3002\u30b7\u30b9\u30c6\u30e0\u306f\u3001\u30cf\u30a4\u30d6\u30ea\u30c0\u30a4\u30bc\u30fc\u30b7\u30e7\u30f3\u88c5\u7f6e\u300cApplied Biosystems\u2122 GeneChipTM Hybridization Oven 645\u300d\u3001\u81ea\u52d5\u6d17\u6d44\u30fb\u67d3\u8272\u88c5\u7f6e\u300cApplied Biosystems\u2122 GeneChipTM Fluidics Sta\uff54ion 450\u300d\u3001\u305d\u3057\u3066\u30b9\u30ad\u30e3\u30ca\u30fc\u300cApplied Biosystems\u2122 GeneChipTM Scanner 3000 7G\u300d\u306e3\u7a2e\u985e\u306e\u88c5\u7f6e\u3067\u69cb\u6210\u3055\u308c\u3066\u3044\u307e\u3059\u3002<\/p>\n<p>\u3053\u308c\u3089\u30b7\u30b9\u30c6\u30e0\u306e\u4e2d\u3067\u64cd\u4f5c\u9593\u9055\u3044\u306b\u3088\u308b\u30c8\u30e9\u30d6\u30eb\u3092\u8d77\u3053\u3059\u53ef\u80fd\u6027\u304c\u9ad8\u3044\u88c5\u7f6e\u304c\u300cGeneChip Fluidics Sta\uff54ion 450\u300d\u3067\u3059\u3002\u4eca\u56de\u306f\u6d17\u6d44\u8a66\u85ac\u3092\u30bb\u30c3\u30c8\u3059\u308b\u4f4d\u7f6e\u3092\u7f6e\u304d\u9593\u9055\u3048\u305f\u5834\u5408\u306b\u8d77\u304d\u308b\u300cMissing Fluid Error\uff08Fluid not detected\uff09\u300d\u306b\u3064\u3044\u3066\u3054\u7d39\u4ecb\u3044\u305f\u3057\u307e\u3059\u3002<\/p>\n<p><span style=\"font-family: 'Helvetica Neue Light', Helvetica, Arial, sans-serif;font-size: 28px\">Missing Fluid Error\u3068\u306f<\/span><\/p>\n<p>Missing Fluid Error\u306fFluidics Station\u306e\u30e9\u30a4\u30f3\u5185\u3092\u901a\u308b\u6db2\u4f53\u306e\u4f1d\u5c0e\u5ea6\uff08\u5869\u6fc3\u5ea6\uff09\u3092\u30bb\u30f3\u30b5\u30fc\u304c\u6e2c\u5b9a\u3057\u3001\u671f\u5f85\u5024\u4ee5\u4e0a\u306e\u5024\u306b\u306a\u3063\u305f\u5834\u5408\u306b\u767a\u751f\u3057\u307e\u3059\u3002\u30b3\u30f3\u30d4\u30e5\u30fc\u30bf\u30fc\u753b\u9762\u306b\u306f\u4e0b\u56f3\u306e\u3088\u3046\u306b\u3001\u3069\u306eFluidics Station\u306e\u3069\u306ePosition\uff08\u30e2\u30b8\u30e5\u30fc\u30eb\u756a\u53f7\uff09\u3067\u30a8\u30e9\u30fc\u304c\u767a\u751f\u3057\u305f\u304b\u30e1\u30c3\u30bb\u30fc\u30b8\u304c\u8868\u793a\u3055\u308c\u307e\u3059\u3002<br \/>\n<img loading=\"lazy\" decoding=\"async\" class=\"aligncenter size-full wp-image-7163\" src=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2020\/06\/PC-Error-message.jpg\" alt=\"\" width=\"356\" height=\"119\" srcset=\"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2020\/06\/PC-Error-message.jpg 356w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2020\/06\/PC-Error-message-300x100.jpg 300w\" sizes=\"auto, (max-width: 356px) 100vw, 356px\" \/><br \/>\n\u305d\u3057\u3066\u3001\u30a8\u30e9\u30fc\u304c\u767a\u751f\u3057\u305fFluidics Station\u306e\u30e2\u30b8\u30e5\u30fc\u30eb\u306e\u6db2\u6676\u753b\u9762\u306b\u306f\u201c\u30a8\u30e9\u30fc\u30e1\u30c3\u30bb\u30fc\u30b8\u306e\u5185\u5bb9\uff08Missing Fluid Error\uff09\u201d\u3001\u201c\u8aad\u307f\u53d6\u3063\u305f\u5024\u3068\u671f\u5f85\u5024\u201d\u3001\u201c\u30a8\u30e9\u30fc\u306e\u767a\u751f\u3057\u305fStage\u201d\u304c\u9806\u756a\u306b\u8868\u793a\u3055\u308c\u307e\u3059\u3002<br \/>\n\u203b\u3053\u308c\u3089\u306e\u30e1\u30c3\u30bb\u30fc\u30b8\u306f\u975e\u5e38\u306b\u91cd\u8981\u306b\u306a\u308b\u305f\u3081\u3001\u30a8\u30e9\u30fc\u767a\u751f\u6642\u306f\u5fc5\u305a\u66f8\u304d\u7559\u3081\u3066\u304a\u3044\u3066\u304f\u3060\u3055\u3044\u3002<\/p>\n<p style=\"text-align: center\"><strong>Missing Fluid Error<\/strong><strong>\u767a\u751f\u6642\u306e<\/strong><strong>\u30e2\u30b8\u30e5\u30fc\u30eb\u6db2\u6676\u753b\u9762\uff1a<\/strong><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter size-full wp-image-7165\" src=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2020\/06\/Figure3-2.jpg\" alt=\"\" width=\"704\" height=\"462\" srcset=\"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2020\/06\/Figure3-2.jpg 704w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2020\/06\/Figure3-2-300x197.jpg 300w\" sizes=\"auto, (max-width: 704px) 100vw, 704px\" \/><\/p>\n<h2>Wash Buffer A \u3068 Wash Buffer B\u306e\u30dc\u30c8\u30eb\u3092\u7f6e\u304d\u9593\u9055\u3048\u305f\u5834\u5408<\/h2>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter size-full wp-image-7175\" src=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2020\/06\/table1-3.jpg\" alt=\"\" width=\"1003\" height=\"142\" srcset=\"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2020\/06\/table1-3.jpg 1003w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2020\/06\/table1-3-300x42.jpg 300w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2020\/06\/table1-3-768x109.jpg 768w\" sizes=\"auto, (max-width: 1003px) 100vw, 1003px\" \/><\/p>\n<p><strong>Missing Fluid Error<\/strong><strong>\u767a\u751f\u6642\u306e<\/strong><strong>\u6db2\u6676\u753b\u9762\uff1a<\/strong><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter size-full wp-image-7166\" src=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2020\/06\/Figure4-2.jpg\" alt=\"\" width=\"646\" height=\"463\" srcset=\"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2020\/06\/Figure4-2.jpg 646w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2020\/06\/Figure4-2-300x215.jpg 300w\" sizes=\"auto, (max-width: 646px) 100vw, 646px\" \/><br \/>\n\u2192\u30d7\u30ed\u30c8\u30b3\u30eb\u958b\u59cb\u6642\u306f\u307e\u305aWash Buffer A\u3067\u6d17\u6d44\u304c\u884c\u308f\u308c\u308b\u305f\u3081\u3001<br \/>\nWash Buffer A \u3068 Wash Buffer B\u306e\u30dc\u30c8\u30eb\u3092\u7f6e\u304d\u9593\u9055\u3048\u305f\u5834\u5408\u306f<br \/>\n\u958b\u59cb\u5f8c\u3059\u3050\u306bMissing Fluid Error\u304c\u767a\u751f\u3057\u307e\u3059\u3002<br \/>\n\u96fb\u6c17\u4f1d\u5c0e\u5ea6\u306e\u6e2c\u5b9a\u5024\u306fWash Buffer B \u3092\u691c\u77e5\u3057\u3066\u304a\u308a\u3001500\uff5e600\u53f0\u306e\u6570\u5024\u3092\u793a\u3057\u307e\u3059\u3002<\/p>\n<p><strong>\u5bfe\u51e6\u65b9\u6cd5\uff1a<\/strong><br \/>\n\u5404\u30e2\u30b8\u30e5\u30fc\u30eb\u306b\u30bb\u30c3\u30c8\u3057\u3066\u3044\u308b\u30a2\u30ec\u30a4\u3092Wash Block\u304b\u3089\u53d6\u308a\u51fa\u3057\u3001\u30a2\u30ec\u30a4\u5185\u3092Wash Buffer A\u306b\u7f6e\u63db\u3001\u906e\u5149\u6761\u4ef6\u4e0b\u3067\u4fdd\u7ba1\u3057\u307e\u3059\u30024\u2103\u906e\u5149\u6761\u4ef6\u4e0b\u3067\u306f3\u6642\u9593\u4fdd\u7ba1\u53ef\u80fd\u3067\u3059\u3002<br \/>\n\u307e\u305f\u3001\u67d3\u8272\u8a66\u85ac\u304a\u3088\u3073Array Holding Buffer\u306e\u30c1\u30e5\u30fc\u30d6\u306f\u30e2\u30b8\u30e5\u30fc\u30eb\u304b\u3089\u4e00\u65e6\u53d6\u308a\u5916\u3057\u3066\u906e\u5149\u6761\u4ef6\u4e0b\u3067\u4fdd\u7ba1\u3057\u307e\u3059\u3002<br \/>\nWash Buffer A\u3068Wash Buffer B\u306e\u30dc\u30c8\u30eb\u3092\u6b63\u3057\u3044\u4f4d\u7f6e\u306b\u30bb\u30c3\u30c8\u3057\u3066\u304b\u3089\u3001PRIME450\u30d7\u30ed\u30c8\u30b3\u30eb\u3092\u5b9f\u65bd\u3057\u3001\u30e9\u30a4\u30f3\u5185\u3092\u6b63\u3057\u3044Buffer\u306b\u7f6e\u63db\u3057\u307e\u3059\u3002\u305d\u306e\u3042\u3068\u306b\u518d\u5ea6\u5404\u30a2\u30ec\u30a4\u306b\u9069\u3057\u305f\u6d17\u6d44\u67d3\u8272\u30d7\u30ed\u30b3\u30eb\u3092\u5b9f\u884c\u3057\u307e\u3059\u3002\u30a8\u30e9\u30fc\u304c\u767a\u751f\u3057\u305f\u5de5\u7a0b\u304b\u3089\u518d\u958b\u3059\u308b\u969b\u306f\u3001\u518d\u958b\u3059\u308b\u5de5\u7a0b\u304c\u30a8\u30e9\u30fc\u306e\u8d77\u304d\u305fStage\u3067\u3042\u308b\u3053\u3068\u3092\u78ba\u8a8d\u3057\u3001Resume\u30dc\u30bf\u30f3\u3092\u62bc\u3057\u3066\u518d\u958b\u3057\u307e\u3059\u3002<\/p>\n<p style=\"text-align: center\"><strong>\uff1c\u6d17\u6d44\u67d3\u8272\u7d42\u4e86\u5f8c\u306e\u30b9\u30ad\u30e3\u30f3\u7d50\u679c\uff1e<\/strong><br \/>\n<img loading=\"lazy\" decoding=\"async\" class=\"aligncenter size-full wp-image-7170\" src=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2020\/06\/Test1-Scan-image.jpg\" alt=\"\" width=\"570\" height=\"565\" srcset=\"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2020\/06\/Test1-Scan-image.jpg 570w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2020\/06\/Test1-Scan-image-300x297.jpg 300w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2020\/06\/Test1-Scan-image-150x150.jpg 150w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2020\/06\/Test1-Scan-image-80x80.jpg 80w\" sizes=\"auto, (max-width: 570px) 100vw, 570px\" \/><br \/>\n<strong>\uff1c\u540c\u4e00\u30b5\u30f3\u30d7\u30eb\u3067\u6b63\u5e38\u306b\u6d17\u6d44\u67d3\u8272\u304c\u7d42\u4e86\u3057\u305f\u3068\u304d\u306e\u30b9\u30ad\u30e3\u30f3\u7d50\u679c\uff1e<\/strong><br \/>\n<img loading=\"lazy\" decoding=\"async\" class=\"aligncenter size-full wp-image-7174\" src=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2020\/06\/20200512_Hela-100ng-1.jpg\" alt=\"\" width=\"570\" height=\"571\" srcset=\"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2020\/06\/20200512_Hela-100ng-1.jpg 570w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2020\/06\/20200512_Hela-100ng-1-300x300.jpg 300w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2020\/06\/20200512_Hela-100ng-1-150x150.jpg 150w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2020\/06\/20200512_Hela-100ng-1-80x80.jpg 80w\" sizes=\"auto, (max-width: 570px) 100vw, 570px\" \/><\/p>\n<p style=\"text-align: left\"><strong>\u25c7SST-RMA\u306b\u3088\u308bNormalization\u5f8c\u306e\u4e21\u30a2\u30ec\u30a4\u7d50\u679c\u306e\u30b7\u30b0\u30ca\u30eb\u76f8\u95a2\u4fc2\u6570\uff08Pearson\u2019s Correlation\uff09\uff1a0.993<\/strong><\/p>\n<h2>Wash Buffer A\u3001\uff22\u306e\u30dc\u30c8\u30eb\u306e\u30bb\u30c3\u30c8\u3092\u5fd8\u308c\u3066\u3001DI Water\u306e\u30dc\u30c8\u30eb\u3092\u30bb\u30c3\u30c8\u3057\u305f\u307e\u307e\u306e\u72b6\u614b\u3067\u6d17\u6d44\u67d3\u8272\u3092\u5b9f\u884c\u3057\u305f\u5834\u5408<\/h2>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter size-full wp-image-7176\" src=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2020\/06\/table2-1.jpg\" alt=\"\" width=\"999\" height=\"141\" srcset=\"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2020\/06\/table2-1.jpg 999w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2020\/06\/table2-1-300x42.jpg 300w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2020\/06\/table2-1-768x108.jpg 768w\" sizes=\"auto, (max-width: 999px) 100vw, 999px\" \/><br \/>\n<strong>Missing Fluid Error\u767a\u751f\u6642\u306e\u30e2\u30b8\u30e5\u30fc\u30eb\u6db2\u6676\u753b\u9762\uff1a<\/strong><br \/>\n<img loading=\"lazy\" decoding=\"async\" class=\"aligncenter size-full wp-image-7167\" src=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2020\/06\/Figure5-2.jpg\" alt=\"\" width=\"703\" height=\"463\" srcset=\"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2020\/06\/Figure5-2.jpg 703w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2020\/06\/Figure5-2-300x198.jpg 300w\" sizes=\"auto, (max-width: 703px) 100vw, 703px\" \/><br \/>\n\u2192\u30d7\u30ed\u30c8\u30b3\u30eb\u958b\u59cb\u6642\u306f\u307e\u305aWash Buffer A\u3067\u6d17\u6d44\u304c\u884c\u308f\u308c\u308b\u305f\u3081\u3001<br \/>\nWash Buffer A \u3068 DI water\u306e\u30dc\u30c8\u30eb\u3092\u7f6e\u304d\u9593\u9055\u3048\u305f\u5834\u5408\u306f<br \/>\n\u958b\u59cb\u5f8c\u3059\u3050\u306bMissing Fluid Error\u304c\u767a\u751f\u3057\u307e\u3059\u3002<br \/>\n\u96fb\u6c17\u4f1d\u5c0e\u5ea6\u306e\u6e2c\u5b9a\u5024\u306fDI water\u3092\u691c\u77e5\u3057\u3066\u304a\u308a\u3001900\u53f0\u306e\u6570\u5024\u3092\u793a\u3057\u307e\u3059\u3002<\/p>\n<p><strong>\u539f\u56e0\uff1a<\/strong>\u6d17\u6d44\u67d3\u8272\u306e\u6700\u521d\u306e\u5de5\u7a0b\u306fWash Buffer A\u3092\u7528\u3044\u305f\u6d17\u6d44\u304c\u884c\u308f\u308c\u307e\u3059\u304c\u3001Wash Buffer A \u306e\u30dc\u30c8\u30eb\u4f4d\u7f6e\u306bDI water\u306e\u30dc\u30c8\u30eb\u3092\u30bb\u30c3\u30c8\u3057\u305f\u305f\u3081\u3001Wash Buffer A\u306e\u30e9\u30a4\u30f3\u5185\u3092DI water\u304c\u6d41\u308c\u3001Missing Fluid Error\u304c\u767a\u751f\u3057\u307e\u3059\u3002<\/p>\n<p><strong>\u5bfe\u51e6\u65b9\u6cd5\uff1a<\/strong><br \/>\n\u5404\u30e2\u30b8\u30e5\u30fc\u30eb\u306b\u30bb\u30c3\u30c8\u3057\u3066\u3044\u308b\u30a2\u30ec\u30a4\u3092Wash Block\u304b\u3089\u53d6\u308a\u51fa\u3057\u3001\u30a2\u30ec\u30a4\u5185\u3092Wash Buffer A\u306b\u7f6e\u63db\u3001\u906e\u5149\u6761\u4ef6\u4e0b\u3067\u4fdd\u7ba1\u3057\u307e\u3059\u30024\u2103\u906e\u5149\u6761\u4ef6\u4e0b\u3067\u306f3\u6642\u9593\u4fdd\u7ba1\u53ef\u80fd\u3067\u3059\u3002<br \/>\n\u307e\u305f\u3001\u67d3\u8272\u8a66\u85ac\u304a\u3088\u3073Array Holding Buffer\u306e\u30c1\u30e5\u30fc\u30d6\u306f\u30e2\u30b8\u30e5\u30fc\u30eb\u304b\u3089\u4e00\u65e6\u53d6\u308a\u5916\u3057\u3066\u906e\u5149\u6761\u4ef6\u4e0b\u3067\u4fdd\u7ba1\u3057\u307e\u3059\u3002<br \/>\nWash Buffer A\u3068DI Water\u306e\u30dc\u30c8\u30eb\u3092\u6b63\u3057\u3044\u4f4d\u7f6e\u306b\u30bb\u30c3\u30c8\u3057\u3066\u304b\u3089\u3001PRIME450\u30d7\u30ed\u30c8\u30b3\u30eb\u3092\u5b9f\u65bd\u3057\u3001\u30e9\u30a4\u30f3\u5185\u3092\u6b63\u3057\u3044Buffer\u306b\u7f6e\u63db\u3057\u307e\u3059\u3002\u305d\u306e\u3042\u3068\u306b\u518d\u5ea6\u5404\u30a2\u30ec\u30a4\u306b\u9069\u3057\u305f\u6d17\u6d44\u67d3\u8272\u30d7\u30ed\u30b3\u30eb\u3092\u5b9f\u884c\u3057\u307e\u3059\u3002\u30a8\u30e9\u30fc\u304c\u767a\u751f\u3057\u305f\u5de5\u7a0b\u304b\u3089\u518d\u958b\u3059\u308b\u969b\u306f\u3001\u518d\u958b\u3059\u308b\u5de5\u7a0b\u304c\u30a8\u30e9\u30fc\u306e\u8d77\u304d\u305fStage\u3067\u3042\u308b\u3053\u3068\u3092\u78ba\u8a8d\u3057\u3001Resume\u30dc\u30bf\u30f3\u3092\u62bc\u3057\u3066\u518d\u958b\u3057\u307e\u3059\u3002<\/p>\n<p style=\"text-align: center\"><strong>\uff1c\u6d17\u6d44\u67d3\u8272\u7d42\u4e86\u5f8c\u306e\u30b9\u30ad\u30e3\u30f3\u7d50\u679c\uff1e<\/strong><br \/>\n<img loading=\"lazy\" decoding=\"async\" class=\"aligncenter size-full wp-image-7172\" src=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2020\/06\/Test3-Scan-image.jpg\" alt=\"\" width=\"562\" height=\"560\" srcset=\"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2020\/06\/Test3-Scan-image.jpg 562w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2020\/06\/Test3-Scan-image-300x300.jpg 300w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2020\/06\/Test3-Scan-image-150x150.jpg 150w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2020\/06\/Test3-Scan-image-80x80.jpg 80w\" sizes=\"auto, (max-width: 562px) 100vw, 562px\" \/><\/p>\n<p style=\"text-align: left\">\u2192Missing Fluid Error\u304c\u767a\u751f\u3059\u308b\u307e\u3067\u306bDI Water\u304c\u308f\u305a\u304b\u306b\u30a2\u30ec\u30a4\u5185\u306b\u5165\u3063\u305f\u3053\u3068\u3067\u3001\u30d7\u30ed\u30fc\u30d6\u304c\u5265\u304c\u308c\u3066\u3057\u307e\u3044\u86cd\u5149\u5f37\u5ea6\u304c\u3084\u3084\u4f4e\u304f\u306a\u3063\u305f\u3068\u8003\u3048\u3089\u308c\u307e\u3059\u3002<\/p>\n<p style=\"text-align: center\"><strong>\uff1c\u540c\u4e00\u30b5\u30f3\u30d7\u30eb\u3067\u6b63\u5e38\u306b\u6d17\u6d44\u67d3\u8272\u304c\u7d42\u4e86\u3057\u305f\u3068\u304d\u306e\u30b9\u30ad\u30e3\u30f3\u7d50\u679c\uff1e<\/strong><br \/>\n<img loading=\"lazy\" decoding=\"async\" class=\"aligncenter size-full wp-image-7171\" src=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2020\/06\/20200512_Hela-50ng-PM.jpg\" alt=\"\" width=\"563\" height=\"559\" srcset=\"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2020\/06\/20200512_Hela-50ng-PM.jpg 563w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2020\/06\/20200512_Hela-50ng-PM-300x298.jpg 300w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2020\/06\/20200512_Hela-50ng-PM-150x150.jpg 150w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2020\/06\/20200512_Hela-50ng-PM-80x80.jpg 80w\" sizes=\"auto, (max-width: 563px) 100vw, 563px\" \/><\/p>\n<p><strong>\u25c7SST-RMA\u306b\u3088\u308bNormalization\u5f8c\u306e\u4e21\u30a2\u30ec\u30a4\u7d50\u679c\u306e\u30b7\u30b0\u30ca\u30eb\u76f8\u95a2\u4fc2\u6570\uff08Pearson\u2019s Correlation\uff09\uff1a0.984<\/strong><\/p>\n<h2>Wash Buffer B\u3068DI Water\u306e\u30dc\u30c8\u30eb\u3092\u7f6e\u304d\u9593\u9055\u3048\u305f\u5834\u5408<\/h2>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter size-full wp-image-7180\" src=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2020\/06\/table3-1.jpg\" alt=\"\" width=\"1002\" height=\"142\" srcset=\"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2020\/06\/table3-1.jpg 1002w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2020\/06\/table3-1-300x43.jpg 300w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2020\/06\/table3-1-768x109.jpg 768w\" sizes=\"auto, (max-width: 1002px) 100vw, 1002px\" \/><br \/>\n<strong>Missing Fluid Error\u767a\u751f\u6642\u306e\u30e2\u30b8\u30e5\u30fc\u30eb\u6db2\u6676\u753b\u9762\uff1a<\/strong><br \/>\n<img loading=\"lazy\" decoding=\"async\" class=\"aligncenter size-full wp-image-7168\" src=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2020\/06\/Figure6-1.jpg\" alt=\"\" width=\"660\" height=\"463\" srcset=\"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2020\/06\/Figure6-1.jpg 660w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2020\/06\/Figure6-1-300x210.jpg 300w\" sizes=\"auto, (max-width: 660px) 100vw, 660px\" \/><br \/>\n\u2192\u30d7\u30ed\u30c8\u30b3\u30eb\u3092\u958b\u59cb\u3059\u308b\u3068\u3001Wash Buffer A\u3067\u6d17\u6d44\u5f8c\u306fWash Buffer B\u3067\u306e\u6d17\u6d44\u304c\u884c\u308f\u308c\u307e\u3059\u3002Wash Buffer B\u3068DI Water\u306e\u30dc\u30c8\u30eb\u3092\u7f6e\u304d\u9593\u9055\u3048\u305f\u5834\u5408\u306fWash Buffer B\u3067\u306e\u6d17\u6d44\u6642\u306bMissing Fluid Error\u304c\u767a\u751f\u3057\u307e\u3059\u3002<br \/>\n\u96fb\u6c17\u4f1d\u5c0e\u5ea6\u306e\u6e2c\u5b9a\u5024\u306fDI Water\u3092\u691c\u77e5\u3057\u3066\u304a\u308a\u3001900\u53f0\u306e\u6570\u5024\u3092\u793a\u3057\u307e\u3059\u3002<\/p>\n<p><strong>\u539f\u56e0\uff1a<\/strong>\u6d17\u6d44\u67d3\u8272\u306eWash Buffer A\u3067\u306e\u6d17\u6d44\u5f8c\u306f\u3001Wash Buffer B\u3067\u306e\u6d17\u6d44\u304c\u884c\u308f\u308c\u308b\u304c\u3001Wash Buffer B \u306e\u30dc\u30c8\u30eb\u4f4d\u7f6e\u306bDI water\u306e\u30dc\u30c8\u30eb\u3092\u30bb\u30c3\u30c8\u3057\u305f\u305f\u3081\u3001Wash Buffer B\u306e\u30e9\u30a4\u30f3\u5185\u3092DI water\u304c\u6d41\u308c\u3066\u3001Missing Fluid Error\u304c\u767a\u751f\u3057\u305f\u3002<\/p>\n<p style=\"text-align: left\">\u5bfe\u51e6\u65b9\u6cd5\uff1a<br \/>\n\u5404\u30e2\u30b8\u30e5\u30fc\u30eb\u306b\u30bb\u30c3\u30c8\u3057\u3066\u3044\u308b\u30a2\u30ec\u30a4\u3092Wash Block\u304b\u3089\u53d6\u308a\u51fa\u3057\u3001\u30a2\u30ec\u30a4\u5185\u3092Wash Buffer A\u306b\u7f6e\u63db\u3001\u906e\u5149\u6761\u4ef6\u4e0b\u3067\u4fdd\u7ba1\u3057\u307e\u3059\u30024\u2103\u906e\u5149\u6761\u4ef6\u4e0b\u3067\u306f3\u6642\u9593\u4fdd\u7ba1\u53ef\u80fd\u3067\u3059\u3002<br \/>\n\u307e\u305f\u3001\u67d3\u8272\u8a66\u85ac\u304a\u3088\u3073Array Holding Buffer\u306e\u30c1\u30e5\u30fc\u30d6\u306f\u30e2\u30b8\u30e5\u30fc\u30eb\u304b\u3089\u4e00\u65e6\u53d6\u308a\u5916\u3057\u3066\u906e\u5149\u6761\u4ef6\u4e0b\u3067\u4fdd\u7ba1\u3057\u307e\u3059\u3002<br \/>\nWash Buffer \uff22\u3068DI Water\u306e\u30dc\u30c8\u30eb\u3092\u6b63\u3057\u3044\u4f4d\u7f6e\u306b\u30bb\u30c3\u30c8\u3057\u3066\u304b\u3089\u3001PRIME450\u30d7\u30ed\u30c8\u30b3\u30eb\u3092\u5b9f\u65bd\u3057\u3001\u30e9\u30a4\u30f3\u5185\u3092\u6b63\u3057\u3044Buffer\u306b\u7f6e\u63db\u3057\u307e\u3059\u3002\u305d\u306e\u3042\u3068\u306b\u518d\u5ea6\u5404\u30a2\u30ec\u30a4\u306b\u9069\u3057\u305f\u6d17\u6d44\u67d3\u8272\u30d7\u30ed\u30b3\u30eb\u3092\u5b9f\u884c\u3057\u307e\u3059\u3002\u30a8\u30e9\u30fc\u304c\u767a\u751f\u3057\u305f\u5de5\u7a0b\u304b\u3089\u518d\u958b\u3059\u308b\u969b\u306f\u3001\u518d\u958b\u3059\u308b\u5de5\u7a0b\u304c\u30a8\u30e9\u30fc\u306e\u8d77\u304d\u305fStage\u3067\u3042\u308b\u3053\u3068\u3092\u78ba\u8a8d\u3057\u3001Resume\u30dc\u30bf\u30f3\u3092\u62bc\u3057\u3066\u518d\u958b\u3057\u307e\u3059\u3002<\/p>\n<p style=\"text-align: center\"><strong>\uff1c\u6d17\u6d44\u67d3\u8272\u7d42\u4e86\u5f8c\u306e\u30b9\u30ad\u30e3\u30f3\u7d50\u679c\uff1e<\/strong><br \/>\n<img loading=\"lazy\" decoding=\"async\" class=\"aligncenter size-full wp-image-7173\" src=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2020\/06\/Test2-Scan-image.jpg\" alt=\"\" width=\"559\" height=\"557\" srcset=\"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2020\/06\/Test2-Scan-image.jpg 559w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2020\/06\/Test2-Scan-image-300x300.jpg 300w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2020\/06\/Test2-Scan-image-150x150.jpg 150w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2020\/06\/Test2-Scan-image-80x80.jpg 80w\" sizes=\"auto, (max-width: 559px) 100vw, 559px\" \/><\/p>\n<p style=\"text-align: left\">\u2192Missing Fluid Error\u304c\u767a\u751f\u3059\u308b\u307e\u3067\u306b\u6570\u56de\uff24\uff29 Water\u3067\u306e\u6d17\u6d44\u304c\u884c\u308f\u308c\u3066\u3057\u307e\u3063\u305f\u305f\u3081\u30d7\u30ed\u30fc\u30d6\u304c\u5265\u304c\u308c\u3066\u3057\u307e\u3044\u3001\u5168\u4f53\u7684\u306b\u86cd\u5149\u5f37\u5ea6\u304c\u4f4e\u304f\u306a\u3063\u3066\u3044\u307e\u3059\u3002<br \/>\n\u3053\u306e\u3088\u3046\u306a\u5834\u5408\u306b\u306f\u30cf\u30a4\u30d6\u30ea\u30c0\u30a4\u30bc\u30fc\u30b7\u30e7\u30f3\u5de5\u7a0b\u304b\u3089\u306e\u3084\u308a\u76f4\u3057\u3092\u63a8\u5968\u3057\u307e\u3059\u3002<\/p>\n<p style=\"text-align: center\"><strong>\uff1c\u540c\u4e00\u30b5\u30f3\u30d7\u30eb\u3067\u6b63\u5e38\u306b\u6d17\u6d44\u67d3\u8272\u304c\u7d42\u4e86\u3057\u305f\u3068\u304d\u306e\u30b9\u30ad\u30e3\u30f3\u7d50\u679c\uff1e<\/strong><br \/>\n<img loading=\"lazy\" decoding=\"async\" class=\"aligncenter size-full wp-image-7174\" src=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2020\/06\/20200512_Hela-100ng-1.jpg\" alt=\"\" width=\"570\" height=\"571\" srcset=\"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2020\/06\/20200512_Hela-100ng-1.jpg 570w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2020\/06\/20200512_Hela-100ng-1-300x300.jpg 300w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2020\/06\/20200512_Hela-100ng-1-150x150.jpg 150w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2020\/06\/20200512_Hela-100ng-1-80x80.jpg 80w\" sizes=\"auto, (max-width: 570px) 100vw, 570px\" \/><\/p>\n<p><strong>\u25c7SST-RMA\u306b\u3088\u308bNormalization\u5f8c\u306e\u4e21\u30a2\u30ec\u30a4\u7d50\u679c\u306e\u30b7\u30b0\u30ca\u30eb\u76f8\u95a2\u4fc2\u6570\uff08Pearson\u2019s Correlation\uff09\uff1a0.652<\/strong><\/p>\n<h2>\u5404\u30dc\u30c8\u30eb\u3092\u30bb\u30c3\u30c8\u3057\u3066\u3044\u308b\u4f4d\u7f6e\u306f\u6b63\u3057\u3044\u306e\u306bMissing Fluid Error\u304c\u767a\u751f\u3059\u308b\u3002<\/h2>\n<p>\u96fb\u6c17\u4f1d\u5c0e\u5ea6\u306e\u6e2c\u5b9a\u5024\u304c900\u53f0\u8fd1\u4f4d\u3067\u3001\u30dc\u30c8\u30eb\u306e\u4f4d\u7f6e\u304c\u6b63\u3057\u304f\u30bb\u30c3\u30c8\u3055\u308c\u3066\u3044\u308b\u5834\u5408\u306b\u306f\u3001\u30e9\u30a4\u30f3\u5185\u306e\u7a7a\u6c17\u3092\u691c\u77e5\u3057\u3066\u3044\u308b\u53ef\u80fd\u6027\u304c\u8003\u3048\u3089\u308c\u307e\u3059\u3002<\/p>\n<p><strong>\u539f\u56e0\uff1a<\/strong><br \/>\n\u6d17\u6d44\u67d3\u8272\u5b9f\u65bd\u524d\u306ePRIME 450\u5b9f\u65bd\u6642\u306b\u30e9\u30a4\u30f3\u5185\u306b\u3042\u308b\u7a7a\u6c17\u3092\u9664\u53bb\u3067\u304d\u3066\u3044\u306a\u304b\u3063\u305f\u3001\u30dc\u30c8\u30eb\u5185\u306eBuffer\u91cf\u304c\u4e0d\u8db3\u3057\u7a7a\u6c17\u3092\u5438\u3044\u8fbc\u3093\u3067\u3057\u307e\u3063\u305f\u3001\u3042\u308b\u3044\u306f\u30dc\u30c8\u30eb\u5185\u306eBuffer\u5438\u3044\u8fbc\u307f\u53e3\u306e\u30e9\u30a4\u30f3\u304c\u53cd\u308a\u8fd4\u308a\u30dc\u30c8\u30eb\u5185\u306eBuffer\u6db2\u9762\u3088\u308a\u9ad8\u3044\u4f4d\u7f6e\u306b\u51fa\u3066\u3057\u307e\u3063\u305f\u3053\u3068\u3067\u7a7a\u6c17\u3092\u5438\u3044\u8fbc\u3093\u3067\u3057\u307e\u3063\u305f\u7b49\u304c\u539f\u56e0\u3068\u3057\u3066\u8003\u3048\u3089\u308c\u307e\u3059\u3002<\/p>\n<p><strong>\u5bfe\u51e6\u65b9\u6cd5\uff1a<\/strong><br \/>\n\u5404\u30e2\u30b8\u30e5\u30fc\u30eb\u306b\u30bb\u30c3\u30c8\u3057\u3066\u3044\u308b\u30a2\u30ec\u30a4\u3092Wash Block\u304b\u3089\u53d6\u308a\u51fa\u3057\u3001\u30a2\u30ec\u30a4\u5185\u3092Wash Buffer A\u306b\u7f6e\u63db\u3001\u906e\u5149\u6761\u4ef6\u4e0b\u3067\u4fdd\u7ba1\u3057\u307e\u3059\u30024\u2103\u906e\u5149\u6761\u4ef6\u4e0b\u3067\u306f3\u6642\u9593\u4fdd\u7ba1\u53ef\u80fd\u3067\u3059\u3002<br \/>\n\u307e\u305f\u3001\u67d3\u8272\u8a66\u85ac\u304a\u3088\u3073Array Holding Buffer\u306e\u30c1\u30e5\u30fc\u30d6\u306f\u30e2\u30b8\u30e5\u30fc\u30eb\u304b\u3089\u4e00\u65e6\u53d6\u308a\u5916\u3057\u3066\u906e\u5149\u6761\u4ef6\u4e0b\u3067\u4fdd\u7ba1\u3057\u307e\u3059\u3002<br \/>\n\u518d\u5ea6PRIME450\u30d7\u30ed\u30c8\u30b3\u30eb\u3092\u5b9f\u65bd\u3057\u3001\u30e9\u30a4\u30f3\u5185\u306b\u542b\u307e\u308c\u308b\u6c17\u6ce1\u3092\u9664\u53bb\u3057\u307e\u3059\u3002\u305d\u306e\u3042\u3068\u306b\u518d\u5ea6\u5404\u30a2\u30ec\u30a4\u306b\u9069\u3057\u305f\u6d17\u6d44\u67d3\u8272\u30d7\u30ed\u30b3\u30eb\u3092\u5b9f\u884c\u3057\u307e\u3059\u3002\u30a8\u30e9\u30fc\u306e\u767a\u751f\u3057\u305f\u30d7\u30ed\u30c8\u30b3\u30eb\u306e\u4f4d\u7f6e\u304b\u3089\u518d\u958b\u3059\u308b\u5834\u5408\u306f\u3001\u30a8\u30e9\u30fc\u304c\u8d77\u304d\u305fStage\u3092\u78ba\u8a8d\u3057\u3001\u30d7\u30ed\u30c8\u30b3\u30eb\u306eStep\u3092Restart Step\u306b\u5909\u66f4\u3057\u3066\u518d\u958b\u3057\u307e\u3059\u3002<br \/>\n\u203bPRIME 450 \u5b9f\u65bd\u5f8c\u3001\u30d7\u30ed\u30c8\u30b3\u30eb\u3092\u518d\u958b\u3057\u3066\u3082\u540c\u69d8\u306e\u30a8\u30e9\u30fc\u304c\u767a\u751f\u3059\u308b\u5834\u5408\u306f\u30b7\u30b9\u30c6\u30e0\u81ea\u4f53\u306b\u30c8\u30e9\u30d6\u30eb\u304c\u8d77\u304d\u3066\u3044\u308b\u53ef\u80fd\u6027\u304c\u9ad8\u3044\u3068\u8003\u3048\u3089\u308c\u307e\u3059\u3002\u5f0a\u793e\u30c6\u30af\u30cb\u30ab\u30eb\u30b5\u30dd\u30fc\u30c8\u3082\u3057\u304f\u306f\u30d5\u30a3\u30fc\u30eb\u30c9\u30a8\u30f3\u30b8\u30cb\u30a2\u307e\u3067\u3054\u9023\u7d61\u304f\u3060\u3055\u3044\u3002<\/p>\n<h2>\u307e\u3068\u3081<\/h2>\n<p>\u30fb\u6d17\u6d44\u8a66\u85ac\u306e\u7f6e\u304d\u9593\u9055\u3044\u306b\u3088\u3063\u3066\u306f\u30a2\u30ec\u30a4\u306e\u7d50\u679c\u3092\u5f97\u3089\u308c\u306a\u3044\u3053\u3068\u304c\u3042\u308b\u305f\u3081\u3001Fluidics Station\u3067\u306e\u6d17\u6d44\u67d3\u8272\u524d\u306b\u306f\u30bb\u30c3\u30c8\u3057\u3066\u3044\u308b\u8a66\u85ac\u306e\u30dc\u30c8\u30eb\u306e\u4f4d\u7f6e\u3092\u3057\u3063\u304b\u308a\u3068\u78ba\u8a8d\u3059\u308b\u3002<\/p>\n<p>\u30c8\u30e9\u30d6\u30eb\u304c\u8d77\u304d\u306a\u3044\u3053\u3068\u304c\u4e00\u756a\u826f\u3044\u3067\u3059\u304c\u3001\u3082\u3057\u30b7\u30b9\u30c6\u30e0\u64cd\u4f5c\u3067\u30c8\u30e9\u30d6\u30eb\u304c\u767a\u751f\u3057\u305f\u969b\u306b\u4e0d\u5b89\u306a\u70b9\u304c\u3054\u3056\u3044\u307e\u3057\u305f\u3089\u304a\u6c17\u8efd\u306b<a href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/jp-contact.html?CID=Gsd_mic_gex_r04_jp_cp1349_pjt5973_gsd00000_0so_blg_op_lgn_kt_s00_ma7_Social_LAB\" target=\"_blank\" rel=\"noopener noreferrer\">\u30c6\u30af\u30cb\u30ab\u30eb\u30b5\u30dd\u30fc\u30c8<\/a>\u307e\u3067\u304a\u554f\u3044\u5408\u308f\u305b\u304f\u3060\u3055\u3044\u3002<\/p>\n<p>&nbsp;<\/p>\n<p>\u7814\u7a76\u7528\u306b\u306e\u307f\u4f7f\u7528\u3067\u304d\u307e\u3059\u3002\u8a3a\u65ad\u7528\u306b\u306f\u4f7f\u7528\u3044\u305f\u3060\u3051\u307e\u305b\u3093\u3002<\/p>\n","protected":false},"excerpt":{"rendered":"<p>\u3053\u306e\u30d6\u30ed\u30b0\u3067\u306f\u30de\u30a4\u30af\u30ed\u30a2\u30ec\u30a4\u30b7\u30b9\u30c6\u30e0GCS3000 7G System\u3092\u6700\u8fd1\u4f7f\u7528\u3057\u59cb\u3081\u305f\u3051\u308c\u3069\u3082\u3001\u307e\u3060\u6570\u56de\u3057\u304b\u4f7f\u3063\u3066\u304a\u3089\u305a\u4f7f\u3044\u6163\u308c\u3066\u3044\u306a\u3044\u65b9\u5411\u3051\u306b\u3001\u30b7\u30b9\u30c6\u30e0\u64cd\u4f5c\u3067\u3088\u304f\u3042\u308b\u30c8\u30e9\u30d6\u30eb\u4e8b\u4f8b\u3084\u5bfe\u51e6\u65b9\u6cd5\u3092\u3054\u7d39\u4ecb\u3057\u307e\u3059\uff01 GCS 3<\/p>\n","protected":false},"author":975,"featured_media":7174,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_monsterinsights_skip_tracking":false,"_genesis_hide_title":false,"_genesis_hide_breadcrumbs":false,"_genesis_hide_singular_image":false,"_genesis_hide_footer_widgets":false,"_genesis_custom_body_class":"","_genesis_custom_post_class":"","_genesis_layout":"","_jetpack_newsletter_access":"","_jetpack_dont_email_post_to_subs":false,"_jetpack_newsletter_tier_id":0,"_jetpack_memberships_contains_paywalled_content":false,"_jetpack_feature_clip_id":0,"_jetpack_memberships_contains_paid_content":false,"footnotes":"","jetpack_post_was_ever_published":false},"categories":[156],"tags":[28],"division":[],"class_list":{"0":"post-7161","1":"post","2":"type-post","3":"status-publish","4":"format-standard","5":"has-post-thumbnail","7":"category-mol-bio","8":"tag-experiment","9":"entry"},"_selected_authors":"","_selected_reviewers":"","acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v27.8 (Yoast SEO v27.8) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>\u3010\u3084\u3063\u3066\u307f\u305f\u3011\u6d17\u6d44\u67d3\u8272\u7528\u30b7\u30b9\u30c6\u30e0\u5229\u7528\u6642\u306e\u8a66\u85ac\u3092\u7f6e\u304d\u9593\u9055\u3048\u3066\u907a\u4f1d\u5b50\u767a\u73fe\u89e3\u6790\u7528\u30a2\u30ec\u30a4\u306e\u30c7\u30fc\u30bf\u3092\u53d6\u5f97\u3057\u3066\u307f\u305f\u2015\uff11 - Learning at the Bench<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/basic_ma_gsd_ts_1\/\" \/>\n<meta property=\"og:locale\" content=\"ja_JP\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"\u3010\u3084\u3063\u3066\u307f\u305f\u3011\u6d17\u6d44\u67d3\u8272\u7528\u30b7\u30b9\u30c6\u30e0\u5229\u7528\u6642\u306e\u8a66\u85ac\u3092\u7f6e\u304d\u9593\u9055\u3048\u3066\u907a\u4f1d\u5b50\u767a\u73fe\u89e3\u6790\u7528\u30a2\u30ec\u30a4\u306e\u30c7\u30fc\u30bf\u3092\u53d6\u5f97\u3057\u3066\u307f\u305f\u2015\uff11\" \/>\n<meta property=\"og:description\" content=\"\u3053\u306e\u30d6\u30ed\u30b0\u3067\u306f\u30de\u30a4\u30af\u30ed\u30a2\u30ec\u30a4\u30b7\u30b9\u30c6\u30e0GCS3000 7G System\u3092\u6700\u8fd1\u4f7f\u7528\u3057\u59cb\u3081\u305f\u3051\u308c\u3069\u3082\u3001\u307e\u3060\u6570\u56de\u3057\u304b\u4f7f\u3063\u3066\u304a\u3089\u305a\u4f7f\u3044\u6163\u308c\u3066\u3044\u306a\u3044\u65b9\u5411\u3051\u306b\u3001\u30b7\u30b9\u30c6\u30e0\u64cd\u4f5c\u3067\u3088\u304f\u3042\u308b\u30c8\u30e9\u30d6\u30eb\u4e8b\u4f8b\u3084\u5bfe\u51e6\u65b9\u6cd5\u3092\u3054\u7d39\u4ecb\u3057\u307e\u3059\uff01 GCS 3\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/basic_ma_gsd_ts_1\/\" \/>\n<meta property=\"og:site_name\" content=\"Learning at the Bench\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/ThermoFisherJapan\" \/>\n<meta property=\"article:published_time\" content=\"2020-06-19T01:19:41+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2021-12-02T02:05:31+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2020\/06\/20200512_Hela-100ng-1.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"570\" \/>\n\t<meta property=\"og:image:height\" content=\"571\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"LatB Staff\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:creator\" content=\"@ThermoFisherJP\" \/>\n<meta name=\"twitter:site\" content=\"@ThermoFisherJP\" \/>\n<meta name=\"twitter:label1\" content=\"\u57f7\u7b46\u8005\" \/>\n\t<meta name=\"twitter:data1\" content=\"LatB Staff\" \/>\n\t<meta name=\"twitter:label2\" content=\"\u63a8\u5b9a\u8aad\u307f\u53d6\u308a\u6642\u9593\" \/>\n\t<meta name=\"twitter:data2\" content=\"1\u5206\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/basic_ma_gsd_ts_1\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/basic_ma_gsd_ts_1\\\/\"},\"author\":{\"name\":\"LatB Staff\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#\\\/schema\\\/person\\\/bdbe319a2001f279ddce6ab8eaad1253\"},\"headline\":\"\u3010\u3084\u3063\u3066\u307f\u305f\u3011\u6d17\u6d44\u67d3\u8272\u7528\u30b7\u30b9\u30c6\u30e0\u5229\u7528\u6642\u306e\u8a66\u85ac\u3092\u7f6e\u304d\u9593\u9055\u3048\u3066\u907a\u4f1d\u5b50\u767a\u73fe\u89e3\u6790\u7528\u30a2\u30ec\u30a4\u306e\u30c7\u30fc\u30bf\u3092\u53d6\u5f97\u3057\u3066\u307f\u305f\u2015\uff11\",\"datePublished\":\"2020-06-19T01:19:41+00:00\",\"dateModified\":\"2021-12-02T02:05:31+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/basic_ma_gsd_ts_1\\\/\"},\"wordCount\":264,\"commentCount\":0,\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/basic_ma_gsd_ts_1\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2020\\\/06\\\/20200512_Hela-100ng-1.jpg\",\"keywords\":[\"\u3084\u3063\u3066\u307f\u305f\"],\"articleSection\":[\"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023\"],\"inLanguage\":\"ja\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/basic_ma_gsd_ts_1\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/basic_ma_gsd_ts_1\\\/\",\"url\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/basic_ma_gsd_ts_1\\\/\",\"name\":\"\u3010\u3084\u3063\u3066\u307f\u305f\u3011\u6d17\u6d44\u67d3\u8272\u7528\u30b7\u30b9\u30c6\u30e0\u5229\u7528\u6642\u306e\u8a66\u85ac\u3092\u7f6e\u304d\u9593\u9055\u3048\u3066\u907a\u4f1d\u5b50\u767a\u73fe\u89e3\u6790\u7528\u30a2\u30ec\u30a4\u306e\u30c7\u30fc\u30bf\u3092\u53d6\u5f97\u3057\u3066\u307f\u305f\u2015\uff11 - Learning at the Bench\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/basic_ma_gsd_ts_1\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/basic_ma_gsd_ts_1\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2020\\\/06\\\/20200512_Hela-100ng-1.jpg\",\"datePublished\":\"2020-06-19T01:19:41+00:00\",\"dateModified\":\"2021-12-02T02:05:31+00:00\",\"author\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#\\\/schema\\\/person\\\/bdbe319a2001f279ddce6ab8eaad1253\"},\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/basic_ma_gsd_ts_1\\\/#breadcrumb\"},\"inLanguage\":\"ja\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/basic_ma_gsd_ts_1\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"ja\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/basic_ma_gsd_ts_1\\\/#primaryimage\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2020\\\/06\\\/20200512_Hela-100ng-1.jpg\",\"contentUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2020\\\/06\\\/20200512_Hela-100ng-1.jpg\",\"width\":570,\"height\":571},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/basic_ma_gsd_ts_1\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"\u3010\u3084\u3063\u3066\u307f\u305f\u3011\u6d17\u6d44\u67d3\u8272\u7528\u30b7\u30b9\u30c6\u30e0\u5229\u7528\u6642\u306e\u8a66\u85ac\u3092\u7f6e\u304d\u9593\u9055\u3048\u3066\u907a\u4f1d\u5b50\u767a\u73fe\u89e3\u6790\u7528\u30a2\u30ec\u30a4\u306e\u30c7\u30fc\u30bf\u3092\u53d6\u5f97\u3057\u3066\u307f\u305f\u2015\uff11\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#website\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/\",\"name\":\"Learning at the Bench\",\"description\":\"\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"ja\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#\\\/schema\\\/person\\\/bdbe319a2001f279ddce6ab8eaad1253\",\"name\":\"LatB Staff\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"ja\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g\",\"caption\":\"LatB Staff\"},\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/author\\\/lgbadmin\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"\u3010\u3084\u3063\u3066\u307f\u305f\u3011\u6d17\u6d44\u67d3\u8272\u7528\u30b7\u30b9\u30c6\u30e0\u5229\u7528\u6642\u306e\u8a66\u85ac\u3092\u7f6e\u304d\u9593\u9055\u3048\u3066\u907a\u4f1d\u5b50\u767a\u73fe\u89e3\u6790\u7528\u30a2\u30ec\u30a4\u306e\u30c7\u30fc\u30bf\u3092\u53d6\u5f97\u3057\u3066\u307f\u305f\u2015\uff11 - Learning at the Bench","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/basic_ma_gsd_ts_1\/","og_locale":"ja_JP","og_type":"article","og_title":"\u3010\u3084\u3063\u3066\u307f\u305f\u3011\u6d17\u6d44\u67d3\u8272\u7528\u30b7\u30b9\u30c6\u30e0\u5229\u7528\u6642\u306e\u8a66\u85ac\u3092\u7f6e\u304d\u9593\u9055\u3048\u3066\u907a\u4f1d\u5b50\u767a\u73fe\u89e3\u6790\u7528\u30a2\u30ec\u30a4\u306e\u30c7\u30fc\u30bf\u3092\u53d6\u5f97\u3057\u3066\u307f\u305f\u2015\uff11","og_description":"\u3053\u306e\u30d6\u30ed\u30b0\u3067\u306f\u30de\u30a4\u30af\u30ed\u30a2\u30ec\u30a4\u30b7\u30b9\u30c6\u30e0GCS3000 7G System\u3092\u6700\u8fd1\u4f7f\u7528\u3057\u59cb\u3081\u305f\u3051\u308c\u3069\u3082\u3001\u307e\u3060\u6570\u56de\u3057\u304b\u4f7f\u3063\u3066\u304a\u3089\u305a\u4f7f\u3044\u6163\u308c\u3066\u3044\u306a\u3044\u65b9\u5411\u3051\u306b\u3001\u30b7\u30b9\u30c6\u30e0\u64cd\u4f5c\u3067\u3088\u304f\u3042\u308b\u30c8\u30e9\u30d6\u30eb\u4e8b\u4f8b\u3084\u5bfe\u51e6\u65b9\u6cd5\u3092\u3054\u7d39\u4ecb\u3057\u307e\u3059\uff01 GCS 3","og_url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/basic_ma_gsd_ts_1\/","og_site_name":"Learning at the Bench","article_publisher":"https:\/\/www.facebook.com\/ThermoFisherJapan","article_published_time":"2020-06-19T01:19:41+00:00","article_modified_time":"2021-12-02T02:05:31+00:00","og_image":[{"width":570,"height":571,"url":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2020\/06\/20200512_Hela-100ng-1.jpg","type":"image\/jpeg"}],"author":"LatB Staff","twitter_card":"summary_large_image","twitter_creator":"@ThermoFisherJP","twitter_site":"@ThermoFisherJP","twitter_misc":{"\u57f7\u7b46\u8005":"LatB Staff","\u63a8\u5b9a\u8aad\u307f\u53d6\u308a\u6642\u9593":"1\u5206"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/basic_ma_gsd_ts_1\/#article","isPartOf":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/basic_ma_gsd_ts_1\/"},"author":{"name":"LatB Staff","@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#\/schema\/person\/bdbe319a2001f279ddce6ab8eaad1253"},"headline":"\u3010\u3084\u3063\u3066\u307f\u305f\u3011\u6d17\u6d44\u67d3\u8272\u7528\u30b7\u30b9\u30c6\u30e0\u5229\u7528\u6642\u306e\u8a66\u85ac\u3092\u7f6e\u304d\u9593\u9055\u3048\u3066\u907a\u4f1d\u5b50\u767a\u73fe\u89e3\u6790\u7528\u30a2\u30ec\u30a4\u306e\u30c7\u30fc\u30bf\u3092\u53d6\u5f97\u3057\u3066\u307f\u305f\u2015\uff11","datePublished":"2020-06-19T01:19:41+00:00","dateModified":"2021-12-02T02:05:31+00:00","mainEntityOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/basic_ma_gsd_ts_1\/"},"wordCount":264,"commentCount":0,"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/basic_ma_gsd_ts_1\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2020\/06\/20200512_Hela-100ng-1.jpg","keywords":["\u3084\u3063\u3066\u307f\u305f"],"articleSection":["\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023"],"inLanguage":"ja","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/basic_ma_gsd_ts_1\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/basic_ma_gsd_ts_1\/","url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/basic_ma_gsd_ts_1\/","name":"\u3010\u3084\u3063\u3066\u307f\u305f\u3011\u6d17\u6d44\u67d3\u8272\u7528\u30b7\u30b9\u30c6\u30e0\u5229\u7528\u6642\u306e\u8a66\u85ac\u3092\u7f6e\u304d\u9593\u9055\u3048\u3066\u907a\u4f1d\u5b50\u767a\u73fe\u89e3\u6790\u7528\u30a2\u30ec\u30a4\u306e\u30c7\u30fc\u30bf\u3092\u53d6\u5f97\u3057\u3066\u307f\u305f\u2015\uff11 - Learning at the Bench","isPartOf":{"@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/basic_ma_gsd_ts_1\/#primaryimage"},"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/basic_ma_gsd_ts_1\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2020\/06\/20200512_Hela-100ng-1.jpg","datePublished":"2020-06-19T01:19:41+00:00","dateModified":"2021-12-02T02:05:31+00:00","author":{"@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#\/schema\/person\/bdbe319a2001f279ddce6ab8eaad1253"},"breadcrumb":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/basic_ma_gsd_ts_1\/#breadcrumb"},"inLanguage":"ja","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/basic_ma_gsd_ts_1\/"]}]},{"@type":"ImageObject","inLanguage":"ja","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/basic_ma_gsd_ts_1\/#primaryimage","url":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2020\/06\/20200512_Hela-100ng-1.jpg","contentUrl":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2020\/06\/20200512_Hela-100ng-1.jpg","width":570,"height":571},{"@type":"BreadcrumbList","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/basic_ma_gsd_ts_1\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/"},{"@type":"ListItem","position":2,"name":"\u3010\u3084\u3063\u3066\u307f\u305f\u3011\u6d17\u6d44\u67d3\u8272\u7528\u30b7\u30b9\u30c6\u30e0\u5229\u7528\u6642\u306e\u8a66\u85ac\u3092\u7f6e\u304d\u9593\u9055\u3048\u3066\u907a\u4f1d\u5b50\u767a\u73fe\u89e3\u6790\u7528\u30a2\u30ec\u30a4\u306e\u30c7\u30fc\u30bf\u3092\u53d6\u5f97\u3057\u3066\u307f\u305f\u2015\uff11"}]},{"@type":"WebSite","@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#website","url":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/","name":"Learning at the Bench","description":"","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"ja"},{"@type":"Person","@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#\/schema\/person\/bdbe319a2001f279ddce6ab8eaad1253","name":"LatB Staff","image":{"@type":"ImageObject","inLanguage":"ja","@id":"https:\/\/secure.gravatar.com\/avatar\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g","caption":"LatB Staff"},"url":"https:\/\/admin.acceleratingscience.com\/author\/lgbadmin\/"}]}},"taxonomy_info":{"category":[{"value":156,"label":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023"}],"post_tag":[{"value":28,"label":"\u3084\u3063\u3066\u307f\u305f"}]},"featured_image_src_large":["https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2020\/06\/20200512_Hela-100ng-1.jpg",570,571,false],"author_info":{"display_name":"LatB Staff","author_link":"https:\/\/admin.acceleratingscience.com\/author\/lgbadmin\/"},"comment_info":0,"category_info":[{"term_id":156,"name":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","slug":"mol-bio","term_group":0,"term_taxonomy_id":156,"taxonomy":"category","description":"","parent":0,"count":538,"filter":"raw","meta":[],"cat_ID":156,"category_count":538,"category_description":"","cat_name":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","category_nicename":"mol-bio","category_parent":0}],"tag_info":[{"term_id":28,"name":"\u3084\u3063\u3066\u307f\u305f","slug":"experiment","term_group":0,"term_taxonomy_id":28,"taxonomy":"post_tag","description":"","parent":0,"count":73,"filter":"raw","meta":[]}],"jetpack-related-posts":[{"id":23370,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/pcr-dna-gsd-ts-tr-25061\/","url_meta":{"origin":7161,"position":0},"title":"\u3010\u3084\u3063\u3066\u307f\u305f\u3011PCR\u5f8c\u306e\u4fdd\u5b58\u6e29\u5ea6\u306f4\u2103\u4e00\u629e\u3067\u3059\u304b\uff1f\u4ed6\u306e\u6e29\u5ea6\u3082\u8a66\u3057\u3066\u307f\u305f","author":"LatB Staff","date":"2025\u5e7410\u670816\u65e5","format":false,"excerpt":"PCR\uff08\u30dd\u30ea\u30e1\u30e9\u30fc\u30bc\u9023\u9396\u53cd\u5fdc\uff09\u306f\u3001\u5206\u5b50\u751f\u7269\u5b66\u306e\u5b9f\u9a13\u306e\u6839\u5e79\u3092\u306a\u3059\u975e\u5e38\u306b\u91cd\u8981\u306a\u6280\u8853\u3067\u3059\u3002PCR\u3092\u884c\u3063\u305f\u5f8c\u2026","rel":"","context":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","block_context":{"text":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/mol-bio\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/10\/pcr-dna-gsd-ts-tr-25061_eyecatch.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/10\/pcr-dna-gsd-ts-tr-25061_eyecatch.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/10\/pcr-dna-gsd-ts-tr-25061_eyecatch.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/10\/pcr-dna-gsd-ts-tr-25061_eyecatch.jpg?resize=700%2C400&ssl=1 2x"},"classes":[]},{"id":24545,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/digital-pcr-gene-expression-gsd-ts-sd-25082\/","url_meta":{"origin":7161,"position":1},"title":"\u3010Absolute Q\u30c7\u30b8\u30bf\u30ebPCR\u30b7\u30b9\u30c6\u30e0\u306e\u6d3b\u7528\u4f8b\u3011\u30df\u30c8\u30b3\u30f3\u30c9\u30ea\u30a2DNA\u306e\u5b9a\u91cf","author":"LatB Staff","date":"2026\u5e741\u670816\u65e5","format":false,"excerpt":"Applied Biosystems\u2122 QuantStudio\u2122 Absolute Q\u2122 \u30c7\u30b8\u30bf\u30ebP\u2026","rel":"","context":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","block_context":{"text":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/mol-bio\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/12\/digital-pcr-gene-expression-gsd-ts-sd-25082_eyecatch.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/12\/digital-pcr-gene-expression-gsd-ts-sd-25082_eyecatch.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/12\/digital-pcr-gene-expression-gsd-ts-sd-25082_eyecatch.jpg?resize=525%2C300&ssl=1 1.5x"},"classes":[]},{"id":24416,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/cell-imaging-fluorescent-dye-bid-ts-mbr-25076\/","url_meta":{"origin":7161,"position":2},"title":"Cell Painting Assay\u3067\u7528\u3044\u3089\u308c\u308b\u8a66\u85ac\u306b\u3064\u3044\u3066\uff08MitoTracker\u3092\u7528\u3044\u305f\u30df\u30c8\u30b3\u30f3\u30c9\u30ea\u30a2\u67d3\u8272\uff09","author":"LatB Staff","date":"2025\u5e7412\u670819\u65e5","format":false,"excerpt":"\u8fd1\u5e74\u3001\u30bb\u30eb\u30da\u30a4\u30f3\u30c6\u30a3\u30f3\u30b0\uff08Cell Painting\uff09\u3068\u3044\u3046\u30a2\u30c3\u30bb\u30a4\u65b9\u6cd5\u304c\u5e83\u307e\u308a\u3064\u3064\u3042\u308a\u307e\u3059\u3002\u4f8b\u3048\u3070\u2026","rel":"","context":"\u7d30\u80de\u57f9\u990a\u30fb\u30a4\u30e1\u30fc\u30b8\u30f3\u30b0","block_context":{"text":"\u7d30\u80de\u57f9\u990a\u30fb\u30a4\u30e1\u30fc\u30b8\u30f3\u30b0","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/cell\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/12\/cell-imaging-fluorescent-dye-bid-ts-mbr-25076_eyecatch-scaled.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/12\/cell-imaging-fluorescent-dye-bid-ts-mbr-25076_eyecatch-scaled.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/12\/cell-imaging-fluorescent-dye-bid-ts-mbr-25076_eyecatch-scaled.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/12\/cell-imaging-fluorescent-dye-bid-ts-mbr-25076_eyecatch-scaled.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/12\/cell-imaging-fluorescent-dye-bid-ts-mbr-25076_eyecatch-scaled.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/12\/cell-imaging-fluorescent-dye-bid-ts-mbr-25076_eyecatch-scaled.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":24382,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/cell-imaging-fluorescent-dye-bid-ts-mbr-25075\/","url_meta":{"origin":7161,"position":3},"title":"Cell Painting Assay\u3067\u7528\u3044\u3089\u308c\u308b\u8a66\u85ac\u306b\u3064\u3044\u3066 (Hoechst\u3092\u7528\u3044\u305f\u6838\u67d3\u8272\uff09","author":"LatB Staff","date":"2025\u5e7412\u670810\u65e5","format":false,"excerpt":"\u8fd1\u5e74\u3001\u30bb\u30eb\u30da\u30a4\u30f3\u30c6\u30a3\u30f3\u30b0\uff08Cell Painting\uff09\u3068\u3044\u3046\u30a2\u30c3\u30bb\u30a4\u65b9\u6cd5\u304c\u5e83\u307e\u308a\u3064\u3064\u3042\u308a\u307e\u3059\u3002\u7d30\u80de\u306b\u2026","rel":"","context":"\u7d30\u80de\u57f9\u990a\u30fb\u30a4\u30e1\u30fc\u30b8\u30f3\u30b0","block_context":{"text":"\u7d30\u80de\u57f9\u990a\u30fb\u30a4\u30e1\u30fc\u30b8\u30f3\u30b0","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/cell\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/11\/cell-imaging-fluorescent-dye-bid-ts-mbr-25075_eyecatch-scaled.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/11\/cell-imaging-fluorescent-dye-bid-ts-mbr-25075_eyecatch-scaled.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/11\/cell-imaging-fluorescent-dye-bid-ts-mbr-25075_eyecatch-scaled.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/11\/cell-imaging-fluorescent-dye-bid-ts-mbr-25075_eyecatch-scaled.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/11\/cell-imaging-fluorescent-dye-bid-ts-mbr-25075_eyecatch-scaled.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/11\/cell-imaging-fluorescent-dye-bid-ts-mbr-25075_eyecatch-scaled.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":24953,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/ngs-gene-expression-csd-ts-ion-26011\/","url_meta":{"origin":7161,"position":4},"title":"\u30e9\u30a4\u30d6\u30e9\u30ea\u30fc\u8abf\u88fd\u306e\u81ea\u52d5\u5316\u3067NGS\u306e\u53ef\u80fd\u6027\u3092\u5e83\u3052\u308b\u2015Ion Chef\u30b7\u30b9\u30c6\u30e0\u304c\u5909\u3048\u308b\u7814\u7a76\u5ba4\u306e\u30ef\u30fc\u30af\u30d5\u30ed\u30fc","author":"LatB Staff","date":"2026\u5e744\u670810\u65e5","format":false,"excerpt":"\u524d\u51e6\u7406\u306e\u81ea\u52d5\u5316\u304c\u3001NGS\u306e\u65b0\u3057\u3044\u6a19\u6e96\u3092\u3064\u304f\u308b\u6b21\u4e16\u4ee3\u30b7\u30fc\u30b1\u30f3\u30b7\u30f3\u30b0\uff08NGS\uff09\u304c\u65e5\u5e38\u7684\u306a\u7814\u7a76\u30c4\u30fc\u30eb\u3068\u306a\u3063\u2026","rel":"","context":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","block_context":{"text":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/mol-bio\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/02\/ngs-gene-expression-csd-ts-ion-26011_eyecatch.jpeg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/02\/ngs-gene-expression-csd-ts-ion-26011_eyecatch.jpeg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/02\/ngs-gene-expression-csd-ts-ion-26011_eyecatch.jpeg?resize=525%2C300&ssl=1 1.5x"},"classes":[]},{"id":24427,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/twin-screw-extrusion-extruder-cad-25076\/","url_meta":{"origin":7161,"position":5},"title":"\u4e8c\u8ef8\u62bc\u51fa\u6a5f\u306e\u57fa\u790e\u2467\uff1a\u5f8c\u5de5\u7a0b\u3068\u30b5\u30f3\u30d7\u30eb\u306e\u56de\u53ce 3D\u30d7\u30ea\u30f3\u30c6\u30a3\u30f3\u30b0\u7528\u30d5\u30a3\u30e9\u30e1\u30f3\u30c8\u306e\u4f5c\u88fd","author":"LatB Staff","date":"2025\u5e7412\u670816\u65e5","format":false,"excerpt":"\u4e8c\u8ef8\u62bc\u51fa\u6a5f\u306e\u57fa\u790e\u30b7\u30ea\u30fc\u30ba\u3067\u306f\u88c5\u7f6e\u306e\u4ed5\u7d44\u307f\u3084\u7279\u9577\u3001\u30d1\u30e9\u30e1\u30fc\u30bf\u30fc\u8a2d\u5b9a\u3084\u305d\u306e\u610f\u5473\u3001\u5f8c\u5de5\u7a0b\u30aa\u30d7\u30b7\u30e7\u30f3\u3092\u7d44\u307f\u5408\u2026","rel":"","context":"\u305d\u306e\u4ed6","block_context":{"text":"\u305d\u306e\u4ed6","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/else\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/12\/0a52b388a96d915f746c8911521e3771.png?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/12\/0a52b388a96d915f746c8911521e3771.png?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/12\/0a52b388a96d915f746c8911521e3771.png?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/12\/0a52b388a96d915f746c8911521e3771.png?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/12\/0a52b388a96d915f746c8911521e3771.png?resize=1050%2C600&ssl=1 3x"},"classes":[]}],"jetpack_sharing_enabled":true,"amp_enabled":true,"jetpack_featured_media_url":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2020\/06\/20200512_Hela-100ng-1.jpg","_links":{"self":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/posts\/7161","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/users\/975"}],"replies":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/comments?post=7161"}],"version-history":[{"count":0,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/posts\/7161\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/media\/7174"}],"wp:attachment":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/media?parent=7161"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/categories?post=7161"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/tags?post=7161"},{"taxonomy":"division","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/division?post=7161"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}