{"id":723,"date":"2017-03-23T00:00:00","date_gmt":"2017-03-23T00:00:00","guid":{"rendered":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/qpcr-basic41\/"},"modified":"2025-04-16T15:22:38","modified_gmt":"2025-04-16T06:22:38","slug":"qpcr-basic41","status":"publish","type":"post","link":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/qpcr-basic41\/","title":{"rendered":"\u86cd\u5149\u30b7\u30b0\u30ca\u30eb\u306b\u5909\u52d5\u3092\u8d77\u3053\u3059\u539f\u56e0\u3068\u306f\uff1f \u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u306b\u304a\u3051\u308b\u5149\u5b66\u7684\u5909\u52d5"},"content":{"rendered":"<p><strong>\u3069\u306e\u3088\u3046\u306a\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u88c5\u7f6e\u306b\u304a\u3044\u3066\u3082\u3001\u9069\u6027\u306a\u6027\u80fd\u3092\u7dad\u6301\u3059\u308b\u305f\u3081\u306b\u3001\u9069\u5207\u306a\u6642\u671f\u306b\u6b63\u78ba\u306a\u88dc\u6b63\u3092\u5b9f\u884c\u3059\u308b\u3053\u3068\u304c\u6975\u3081\u3066\u91cd\u8981\u3067\u3059\u3002<\/strong>\u88dc\u6b63\u306b\u3088\u308a\u3001\u30c7\u30fc\u30bf\u306e\u5b8c\u5168\u6027\u304a\u3088\u3073\u4e00\u8cab\u6027\u304c\u9577\u671f\u9593\u306b\u308f\u305f\u308a\u7dad\u6301\u3055\u308c\u307e\u3059\u3002\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u88c5\u7f6e\u306f\u3001\u5b9a\u671f\u7684\u306a\u30e1\u30f3\u30c6\u30ca\u30f3\u30b9\u306e\u4e00\u74b0\u3068\u3057\u3066\u3001\u307e\u305f\u65b0\u3057\u3044\u8272\u7d20\u3092\u521d\u3081\u3066\u4f7f\u7528\u3059\u308b\u524d\u306b\u3001\u88fd\u9020\u8005\u304b\u3089\u63d0\u4f9b\u3055\u308c\u308b\u53d6\u6271\u8aac\u660e\u66f8\u306b\u5f93\u3063\u3066\u88dc\u6b63\u3059\u308b\u5fc5\u8981\u304c\u3042\u308a\u307e\u3059\u3002<strong>\u4eca\u56de\u306f\u88dc\u6b63\u304c\u5fc5\u8981\u306a\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u306b\u304a\u3051\u308b\u5149\u5b66\u7684\u5909\u52d5\u306b\u3064\u3044\u3066\u307e\u3068\u3081\u307e\u3057\u305f\u306e\u3067\u3054\u7d39\u4ecb\u3057\u307e\u3059\u3002<\/strong><\/p>\n<h2>\u52b1\u8d77\/\u86cd\u5149\u306e\u88dc\u6b63<\/h2>\n<p>\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u88c5\u7f6e\u306e\u5149\u5b66\u7cfb\u306f<strong>\u5927\u304d\u304f2\u3064\u306e\u7a2e\u985e<\/strong>\u306b\u5206\u985e\u3055\u308c\u307e\u3059\u3002\u4e00\u3064\u306f<strong>\u30cf\u30ed\u30b2\u30f3\u30e9\u30f3\u30d7\u3084LED\u306a\u3069\u306e\u52b1\u8d77\u5149\u6e90<\/strong>\u3001\u3082\u3046\u4e00\u3064\u306f<strong>CCD\u307e\u305f\u306f\u30d5\u30a9\u30c8\u30c0\u30a4\u30aa\u30fc\u30c9\u306e\u3088\u3046\u306a\u86cd\u5149\u691c\u51fa\u5668<\/strong>\u3067\u3059\u3002\u88fd\u9020\u30e1\u30fc\u30ab\u30fc\u306b\u3088\u308a\u30d6\u30ed\u30c3\u30af\u5185\u306e\u30a6\u30a7\u30eb\u9593\u306e\u52b1\u8d77\u5f37\u5ea6\u304a\u3088\u3073\u86cd\u5149\u611f\u5ea6\u306b\u95a2\u3057\u305f\u512a\u308c\u305f\u5747\u4e00\u6027\u304c\u5f97\u3089\u308c\u3066\u3044\u307e\u3059\u304c\u3001\u5e38\u306b\u3044\u304f\u3089\u304b\u306e\u5909\u52d5\u306f\u5b58\u5728\u3057\u5f97\u307e\u3059\u3002\u3053\u306e\u5909\u52d5\u306f\u3001\u88c5\u7f6e\u306e\u4f7f\u7528\u5e74\u6570\u304a\u3088\u3073\u4f7f\u7528\u56de\u6570\u306e\u5897\u52a0\u3068\u3068\u3082\u306b\u5897\u5927\u3059\u308b\u53ef\u80fd\u6027\u304c\u3042\u308a\u307e\u3059\u3002\u30d7\u30ec\u30fc\u30c8\u9593\u306e\u88dc\u6b63\u3055\u308c\u3066\u3044\u306a\u3044\u52b1\u8d77\uff0f\u86cd\u5149\u306fCt\u5024\u304c\u30b7\u30d5\u30c8\u3059\u308b\u539f\u56e0\u3068\u306a\u308b\u53ef\u80fd\u6027\u304c\u3042\u308a\u307e\u3059\u3002\u3057\u304b\u3057\u3001\u30d1\u30c3\u30b7\u30d6\u30ec\u30d5\u30a1\u30ec\u30f3\u30b9\u8272\u7d20\u3092\u53cd\u5fdc\u306b\u4f7f\u7528\u3057\u3066\u3044\u308b\u5834\u5408\u306b\u306f\u3001\u3053\u308c\u3089\u306e\u5dee\u306f\u30ec\u30dd\u30fc\u30bf\u30fc\u304a\u3088\u3073\u30d1\u30c3\u30b7\u30d6\u30ec\u30d5\u30a1\u30ec\u30f3\u30b9\u306e\u30b7\u30b0\u30ca\u30eb\u306b\u540c\u7b49\u306e\u5f71\u97ff\u3092\u4e0e\u3048\u308b\u305f\u3081\u3001\u30ec\u30dd\u30fc\u30bf\u30fc\u3092\u30d1\u30c3\u30b7\u30d6\u30ec\u30d5\u30a1\u30ec\u30f3\u30b9\u306b\u5bfe\u3057\u3066\u6a19\u6e96\u5316\u3059\u308b\u3053\u3068\u306b\u3088\u308a\u5dee\u304c\u88dc\u6b63\u3055\u308c\u307e\u3059\u3002<\/p>\n<h2>\u4e00\u822c\u7684\u306a\u5149\u5b66\u7684\u5909\u52d5<\/h2>\n<p>\u5f93\u6765\u306e\u30d7\u30e9\u30b9\u30c1\u30c3\u30af\u88fdPCR\u30d7\u30ec\u30fc\u30c8\u304a\u3088\u3073\u30c1\u30e5\u30fc\u30d6\u306b\u304a\u3044\u3066\u306f\u3001\u6db2\u4f53\u8a66\u85ac\u304c\u30a6\u30a7\u30eb\u306e\u5e95\u90e8\u306b\u3042\u308a\u3001\u305d\u306e\u6db2\u4f53\u306e\u4e0a\u306b\u7a7a\u9699\u304c\u5b58\u5728\u3057\u3001\u30d7\u30e9\u30b9\u30c1\u30c3\u30af\u306e\u30b7\u30fc\u30eb\u304c\u30a6\u30a7\u30eb\u3092\u8986\u3063\u3066\u3044\u307e\u3057\u305f\u3002\u3053\u306e\u5f62\u72b6\u3067\u306f\u6e29\u5ea6\u306b\u95a2\u9023\u3057\u305f\u69d8\u3005\u306a\u73fe\u8c61\u304c\u767a\u751f\u3057\u307e\u3059\u3002<\/p>\n<p>\u30b5\u30a4\u30af\u30eb\u4e2d\u306b\u304a\u3044\u3066\u3001\u6e29\u5ea6\u306f95\u2103\u306b\u9054\u3057\u307e\u3059\u3002\u305d\u306e\u3088\u3046\u306a\u9ad8\u6e29\u306b\u304a\u3044\u3066\u306f\u3001\u6c34\u5206\u306f\u30a6\u30a7\u30eb\u306e\u7a7a\u9699\u3078\u3068\u84b8\u767a\u3057\u3066\u3044\u304d\u307e\u3059\u3002\u3053\u306e\u6c34\u84b8\u6c17\u3042\u308b\u3044\u306f\u30b9\u30c1\u30fc\u30e0\u306f\u30c1\u30e5\u30fc\u30d6\u306e\u4f4e\u6e29\u58c1\u4e0a\u306b\u51dd\u7d50\u3057\u3001\u6c34\u6ef4\u3068\u3057\u3066\u5e95\u90e8\u306e\u8a66\u85ac\u306b\u623b\u3063\u3066\u3044\u304d\u307e\u3059\u3002\u3053\u306e\u300c<strong>\u9084\u6d41<\/strong>\u300d\u3068\u547c\u3070\u308c\u308b\u904e\u7a0b\u306fPCR\u53cd\u5fdc\u3092\u901a\u3057\u3066\u7d99\u7d9a\u3057\u307e\u3059\u3002<\/p>\n<p>\u6b21\u306b\u3001\u9ad8\u6e29\u306b\u304a\u3044\u3066\u306f\u6db2\u4f53\u8a66\u85ac\u4e2d\u306b\u6eb6\u89e3\u3057\u3066\u3044\u308b\u7a7a\u6c17\u306e\u6eb6\u89e3\u5ea6\u304c\u4f4e\u4e0b\u3057\u3001\u5c0f\u3055\u306a\u6c17\u6ce1\u304c\u767a\u751f\u3057\u307e\u3059\u3002<\/p>\n<p>\u3055\u3089\u306b\u3001\u30b9\u30c1\u30fc\u30e0\u306e\u5727\u529b\u304c\u30d7\u30e9\u30b9\u30c1\u30c3\u30af\u306e\u30b7\u30fc\u30eb\u306b\u529b\u3092\u53ca\u307c\u3057\u3001PCR\u306e\u9593\u306b\u30b7\u30fc\u30eb\u306e\u5f62\u72b6\u304c\u5c11\u3057\u5909\u5316\u3057\u307e\u3059\u3002<\/p>\n<p><strong>\u3053\u308c\u3089\u306e\u6e29\u5ea6\u306b\u95a2\u9023\u3057\u305f\u73fe\u8c61\u306f\u3059\u3079\u3066\u3001\u52b1\u8d77\u304a\u3088\u3073\u86cd\u5149\u306e\u5149\u8def\u306b\u304a\u3044\u3066\u767a\u751f\u3057\u3001\u86cd\u5149\u30b7\u30b0\u30ca\u30eb\u306b\u5909\u52d5\u3092\u8d77\u3053\u3059\u539f\u56e0\u3068\u306a\u308b\u53ef\u80fd\u6027\u304c\u3042\u308a\u307e\u3059\u3002<\/strong>\u3053\u308c\u3089\u306e\u5909\u52d5\u306e\u5ea6\u5408\u3044\u306f\u3001\u8a66\u85ac\u306b\u6eb6\u89e3\u3057\u3066\u3044\u308b\u7a7a\u6c17\u306e\u91cf\u3084\u30d7\u30ec\u30fc\u30c8\u304c\u3044\u304b\u306b\u3088\u304f\u30b7\u30fc\u30eb\u3055\u308c\u3066\u3044\u308b\u304b\u3068\u3044\u3063\u305f\u8981\u56e0\u306b\u3088\u3063\u3066\u69d8\u3005\u306b\u5909\u5316\u3057\u307e\u3059\u3002<\/p>\n<p><strong>\u4e00\u822c\u7684\u306b\u3053\u306e\u5149\u5b66\u7684\u5909\u52d5\u306f\u30ec\u30dd\u30fc\u30bf\u30fc\u30b7\u30b0\u30ca\u30eb\u306b\u660e\u3089\u304b\u306a\u6b6a\u307f\u3092\u5f15\u304d\u8d77\u3053\u3059\u3053\u3068\u306f\u3042\u308a\u307e\u305b\u3093\u304c\u3001\u53cd\u5fa9\u306e\u7cbe\u5ea6\u306b\u306f\u5f71\u97ff\u3092\u4e0e\u3048\u307e\u3059\u3002<\/strong>\u30d1\u30c3\u30b7\u30d6\u30ec\u30d5\u30a1\u30ec\u30f3\u30b9\u8272\u7d20\u304c\u5b58\u5728\u3059\u308b\u5834\u5408\u3001\u30d1\u30c3\u30b7\u30d6\u30ec\u30d5\u30a1\u30ec\u30f3\u30b9\u8272\u7d20\u306f\u30ec\u30dd\u30fc\u30bf\u30fc\u3068\u540c\u3058\u5149\u8def\u306b\u5b58\u5728\u3059\u308b\u305f\u3081\u3001\u30ec\u30dd\u30fc\u30bf\u30fc\u3092\u30d1\u30c3\u30b7\u30d6\u30ec\u30d5\u30a1\u30ec\u30f3\u30b9\u306b\u5bfe\u3057\u3066\u6a19\u6e96\u5316\u3059\u308b\u3053\u3068\u306b\u3088\u308a\u3053\u308c\u3089\u306e\u5909\u52d5\u306f\u88dc\u6b63\u3055\u308c\u307e\u3059\u3002<\/p>\n<h2>\u7cbe\u5ea6\u306e\u5411\u4e0a<\/h2>\n<p><strong>\u30d1\u30c3\u30b7\u30d6\u30ec\u30d5\u30a1\u30ec\u30f3\u30b9\u306b\u3088\u308b\u6a19\u6e96\u5316\u306e\u88dc\u6b63\u52b9\u679c\u306f\u3001\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u30c7\u30fc\u30bf\u306e\u7cbe\u5ea6\u3092\u5411\u4e0a\u3055\u305b\u307e\u3059\u3002<\/strong>\u6539\u5584\u306e\u5ea6\u5408\u3044\u306f\u3001\u8a66\u85ac\u3084\u30d7\u30ec\u30fc\u30c8\u306e\u8abf\u88fd\u65b9\u6cd5\u306a\u3069\u3001\u591a\u304f\u306e\u56e0\u5b50\u306b\u3088\u308a\u7570\u306a\u308a\u307e\u3059\u3002<\/p>\n<h2>\u7279\u6b8a\u306a\u5149\u5b66\u7684\u5909\u52d5<\/h2>\n<p><strong>\u7279\u6b8a\u306a\u5149\u5b66\u7684\u5909\u52d5\u306f\u3001\u30b5\u30fc\u30de\u30eb\u30b5\u30a4\u30af\u30eb\u306b\u95a2\u9023\u3057\u305f\u7570\u5e38\u3067\u3001\u30ec\u30dd\u30fc\u30bf\u30fc\u30b7\u30b0\u30ca\u30eb\u306b\u660e\u3089\u304b\u306a\u7570\u5e38\u3092\u5f15\u304d\u8d77\u3053\u3057\u307e\u3059\u304c\u3001\u30e9\u30f3\u4e2d\u306e\u3059\u3079\u3066\u306e\u53cd\u5fdc\u306b\u666e\u904d\u7684\u3067\u306f\u3042\u308a\u307e\u305b\u3093\u3002<\/strong>\u7279\u6b8a\u306a\u5149\u5b66\u7684\u5909\u52d5\u306e\u4e00\u3064\u306e\u4f8b\u306f\u3001\u30d7\u30ec\u30fc\u30c8\u30b7\u30fc\u30eb\u306e\u5927\u304d\u306a\u5f62\u72b6\u5909\u5316\u3067\u3042\u308a\u3001\u300c\u5149\u5b66\u7684\u30ef\u30fc\u30d4\u30f3\u30b0\u300d\u3068\u547c\u3076\u3053\u3068\u3082\u3067\u304d\u307e\u3059\u3002\u5149\u5b66\u7684\u30ef\u30fc\u30d4\u30f3\u30b0\u306f\u3001\u30a6\u30a7\u30eb\u306e\u30b7\u30fc\u30eb\u304c\u4e0d\u5341\u5206\u306a\u5834\u5408\u306b\u3001PCR\u53cd\u5fdc\u4e2d\u306b\u52a0\u71b1\u3055\u308c\u305f\u84cb\u304b\u3089\u306e\u71b1\u3068\u5727\u529b\u306b\u3088\u3063\u3066\u30b7\u30fc\u30eb\u304c\u6b63\u3057\u304f\u88c5\u7740\u3055\u308c\u308b\u3053\u3068\u306b\u3088\u308a\u8d77\u3053\u308a\u307e\u3059\u3002\u3082\u3046\u4e00\u3064\u306e\u4f8b\u306f\u3001PCR\u53cd\u5fdc\u4e2d\u306b\u7834\u88c2\u3059\u308b\u5927\u304d\u306a\u6c17\u6ce1\u306e\u767a\u751f\u3067\u3059\u3002<\/p>\n<p><strong>\u5897\u5e45\u30d7\u30ed\u30c3\u30c8\u306b\u304a\u3051\u308b\u7570\u5e38\u306f\u30d9\u30fc\u30b9\u30e9\u30a4\u30f3\u306b\u554f\u984c\u3092\u5f15\u304d\u8d77\u3053\u3059\u53ef\u80fd\u6027\u304c\u3042\u308a\u3001Ct\u5024\u306b\u3082\u5f71\u97ff\u3092\u53ca\u307c\u3059\u53ef\u80fd\u6027\u304c\u3042\u308a\u307e\u3059\u3002<\/strong>\u30d1\u30c3\u30b7\u30d6\u30ec\u30d5\u30a1\u30ec\u30f3\u30b9\u8272\u7d20\u306b\u5bfe\u3059\u308b\u6a19\u6e96\u5316\u306f\u5149\u5b66\u7684\u30ef\u30fc\u30d4\u30f3\u30b0\u306b\u5bfe\u3059\u308b\u512a\u308c\u305f\u88dc\u6b63\u3092\u63d0\u4f9b\u3059\u308b\u305f\u3081\u3001\u88dc\u6b63\u3055\u308c\u305f\u5897\u5e45\u30d7\u30ed\u30c3\u30c8\u306b\u306f\u5168\u304f\u7570\u5e38\u304c\u898b\u3089\u308c\u306a\u3044\u5834\u5408\u3082\u3042\u308a\u307e\u3059\u3002\u6a19\u6e96\u5316\u306f\u5927\u304d\u306a\u6c17\u6ce1\u306e\u7834\u88c2\u306b\u5bfe\u3059\u308b\u5b8c\u5168\u306a\u88dc\u6b63\u306f\u884c\u3044\u307e\u305b\u3093\u304c\u3001\u5927\u304d\u306a\u6c17\u6ce1\u306e\u7834\u88c2\u306b\u8d77\u56e0\u3059\u308b\u30c7\u30fc\u30bf\u306e\u7570\u5e38\u3092\u6700\u5c0f\u9650\u306b\u6291\u3048\u308b\u3053\u3068\u306f\u53ef\u80fd\u3067\u3059\u3002<\/p>\n<h2>\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u30cf\u30f3\u30c9\u30d6\u30c3\u30af \u7121\u6599\u30c0\u30a6\u30f3\u30ed\u30fc\u30c9<\/h2>\n<p>\u3053\u306e\u30cf\u30f3\u30c9\u30d6\u30c3\u30af\u3067\u306f\u3001\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u306e\u7406\u8ad6\u3084\u5b9f\u9a13\u30c7\u30b6\u30a4\u30f3\u306e\u8a2d\u8a08\u306a\u3069\u3001\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u306e\u57fa\u790e\u77e5\u8b58\u304c\u63b2\u8f09\u3055\u308c\u3066\u3044\u307e\u3059\u3002\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u3092\u59cb\u3081\u305f\u3070\u304b\u308a\u306e\u65b9\u3084\u3053\u308c\u304b\u3089\u5b9f\u9a13\u3092\u8003\u3048\u3066\u3044\u308b\u65b9\u306b\u3046\u3063\u3066\u3064\u3051\u306e\u30cf\u30f3\u30c9\u30d6\u30c3\u30af\u3067\u3059\u3002PDF\u30d5\u30a1\u30a4\u30eb\u306e\u30c0\u30a6\u30f3\u30ed\u30fc\u30c9\u3092\u3054\u5e0c\u671b\u306e\u65b9\u306f\u3001\u4e0b\u8a18\u30dc\u30bf\u30f3\u3088\u308a\u304a\u7533\u3057\u8fbc\u307f\u304f\u3060\u3055\u3044\u3002<\/p>\n<p><a class=\"btn btn-red\" href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/global\/forms\/real-time-pcr-handbook-form.html?CID=gsd_pcr_sbu_r04_jp_cp0000_pjt0000_gsd00000_0so_blg_op_awa_oc_s00_qpcr47_Social_LAB\" target=\"_blank\" rel=\"noopener\">\u30c0\u30a6\u30f3\u30ed\u30fc\u30c9\u3059\u308b<\/a><\/p>\n<h2>\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u30c8\u30e9\u30d6\u30eb\u30b7\u30e5\u30fc\u30c6\u30a3\u30f3\u30b0 \u7121\u6599\u30c0\u30a6\u30f3\u30ed\u30fc\u30c9<\/h2>\n<p>\u7570\u5e38\u306aS\u5b57\u72b6\u306e\u5897\u5e45\u66f2\u7dda\u3001NTC\u3067\u306e\u5897\u5e45\u691c\u51fa\u3001\u5897\u5e45\u304c\u898b\u3089\u308c\u306a\u3044\u306a\u3069\u3001\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u306e\u5b9f\u9a13\u4e2d\u306b\u56f0\u3063\u305f\u969b\u306e\u624b\u52a9\u3051\u306b\u306a\u308b\u60c5\u5831\u3092\u7d39\u4ecb\u3057\u3066\u3044\u307e\u3059\u3002PDF\u30d5\u30a1\u30a4\u30eb\u306e\u30c0\u30a6\u30f3\u30ed\u30fc\u30c9\u3092\u3054\u5e0c\u671b\u306e\u65b9\u306f\u3001\u4e0b\u8a18\u30dc\u30bf\u30f3\u3088\u308a\u304a\u7533\u3057\u8fbc\u307f\u304f\u3060\u3055\u3044\u3002<\/p>\n<p><a class=\"btn btn-red\" href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/global\/forms\/pcr-system-troubleshooting.html?CID=gsd_pcr_sbu_r04_jp_cp0000_pjt0000_gsd00000_0so_blg_op_awa_oc_s00_qpcr47_Social_LAB\" target=\"_blank\" rel=\"noopener\">\u30c0\u30a6\u30f3\u30ed\u30fc\u30c9\u3059\u308b<\/a><\/p>\n<p>&nbsp;<\/p>\n<p>\u7814\u7a76\u7528\u306b\u306e\u307f\u4f7f\u7528\u3067\u304d\u307e\u3059\u3002\u8a3a\u65ad\u7528\u306b\u306f\u4f7f\u7528\u3044\u305f\u3060\u3051\u307e\u305b\u3093\u3002<\/p>\n","protected":false},"excerpt":{"rendered":"<p>\u3069\u306e\u3088\u3046\u306a\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u88c5\u7f6e\u306b\u304a\u3044\u3066\u3082\u3001\u9069\u6027\u306a\u6027\u80fd\u3092\u7dad\u6301\u3059\u308b\u305f\u3081\u306b\u3001\u9069\u5207\u306a\u6642\u671f\u306b\u6b63\u78ba\u306a\u88dc\u6b63\u3092\u5b9f\u884c\u3059\u308b\u3053\u3068\u304c\u6975\u3081\u3066\u91cd\u8981\u3067\u3059\u3002\u88dc\u6b63\u306b\u3088\u308a\u3001\u30c7\u30fc\u30bf\u306e\u5b8c\u5168\u6027\u304a\u3088\u3073\u4e00\u8cab\u6027\u304c\u9577\u671f\u9593\u306b\u308f\u305f\u308a\u7dad\u6301\u3055\u308c\u307e\u3059\u3002\u4eca\u56de\u306f\u88dc\u6b63\u304c\u5fc5\u8981\u306a\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u306b\u304a\u3051\u308b\u5149\u5b66\u7684\u5909\u52d5\u306b\u3064\u3044\u3066\u307e\u3068\u3081\u307e\u3057\u305f\u306e\u3067\u3054\u7d39\u4ecb\u3057\u307e\u3059\u3002<\/p>\n","protected":false},"author":988,"featured_media":3327,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_monsterinsights_skip_tracking":false,"_genesis_hide_title":false,"_genesis_hide_breadcrumbs":false,"_genesis_hide_singular_image":false,"_genesis_hide_footer_widgets":false,"_genesis_custom_body_class":"","_genesis_custom_post_class":"","_genesis_layout":"","_jetpack_newsletter_access":"","_jetpack_dont_email_post_to_subs":false,"_jetpack_newsletter_tier_id":0,"_jetpack_memberships_contains_paywalled_content":false,"_jetpack_feature_clip_id":0,"_jetpack_memberships_contains_paid_content":false,"footnotes":"","jetpack_post_was_ever_published":false},"categories":[156],"tags":[7],"division":[],"class_list":["post-723","post","type-post","status-publish","format-standard","has-post-thumbnail","category-mol-bio","tag-qpcr","entry"],"_selected_authors":"","_selected_reviewers":"","acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v27.8 (Yoast SEO v27.8) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>\u86cd\u5149\u30b7\u30b0\u30ca\u30eb\u306b\u5909\u52d5\u3092\u8d77\u3053\u3059\u539f\u56e0\u3068\u306f\uff1f \u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u306b\u304a\u3051\u308b\u5149\u5b66\u7684\u5909\u52d5 - Learning at the Bench<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/qpcr-basic41\/\" \/>\n<meta property=\"og:locale\" content=\"ja_JP\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"\u86cd\u5149\u30b7\u30b0\u30ca\u30eb\u306b\u5909\u52d5\u3092\u8d77\u3053\u3059\u539f\u56e0\u3068\u306f\uff1f \u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u306b\u304a\u3051\u308b\u5149\u5b66\u7684\u5909\u52d5\" \/>\n<meta property=\"og:description\" content=\"\u3069\u306e\u3088\u3046\u306a\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u88c5\u7f6e\u306b\u304a\u3044\u3066\u3082\u3001\u9069\u6027\u306a\u6027\u80fd\u3092\u7dad\u6301\u3059\u308b\u305f\u3081\u306b\u3001\u9069\u5207\u306a\u6642\u671f\u306b\u6b63\u78ba\u306a\u88dc\u6b63\u3092\u5b9f\u884c\u3059\u308b\u3053\u3068\u304c\u6975\u3081\u3066\u91cd\u8981\u3067\u3059\u3002\u88dc\u6b63\u306b\u3088\u308a\u3001\u30c7\u30fc\u30bf\u306e\u5b8c\u5168\u6027\u304a\u3088\u3073\u4e00\u8cab\u6027\u304c\u9577\u671f\u9593\u306b\u308f\u305f\u308a\u7dad\u6301\u3055\u308c\u307e\u3059\u3002\u4eca\u56de\u306f\u88dc\u6b63\u304c\u5fc5\u8981\u306a\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u306b\u304a\u3051\u308b\u5149\u5b66\u7684\u5909\u52d5\u306b\u3064\u3044\u3066\u307e\u3068\u3081\u307e\u3057\u305f\u306e\u3067\u3054\u7d39\u4ecb\u3057\u307e\u3059\u3002\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/qpcr-basic41\/\" \/>\n<meta property=\"og:site_name\" content=\"Learning at the Bench\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/ThermoFisherJapan\" \/>\n<meta property=\"article:published_time\" content=\"2017-03-23T00:00:00+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2025-04-16T06:22:38+00:00\" \/>\n<meta property=\"og:image\" content=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/qpcr-basic41-title.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"1200\" \/>\n\t<meta property=\"og:image:height\" content=\"630\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"LATB Staff\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:creator\" content=\"@ThermoFisherJP\" \/>\n<meta name=\"twitter:site\" content=\"@ThermoFisherJP\" \/>\n<meta name=\"twitter:label1\" content=\"\u57f7\u7b46\u8005\" \/>\n\t<meta name=\"twitter:data1\" content=\"LATB Staff\" \/>\n\t<meta name=\"twitter:label2\" content=\"\u63a8\u5b9a\u8aad\u307f\u53d6\u308a\u6642\u9593\" \/>\n\t<meta name=\"twitter:data2\" content=\"6\u5206\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/qpcr-basic41\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/qpcr-basic41\\\/\"},\"author\":{\"name\":\"LATB Staff\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#\\\/schema\\\/person\\\/201e6a5abb838fa34e8ff0174b015d36\"},\"headline\":\"\u86cd\u5149\u30b7\u30b0\u30ca\u30eb\u306b\u5909\u52d5\u3092\u8d77\u3053\u3059\u539f\u56e0\u3068\u306f\uff1f \u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u306b\u304a\u3051\u308b\u5149\u5b66\u7684\u5909\u52d5\",\"datePublished\":\"2017-03-23T00:00:00+00:00\",\"dateModified\":\"2025-04-16T06:22:38+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/qpcr-basic41\\\/\"},\"wordCount\":26,\"commentCount\":0,\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/qpcr-basic41\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2019\\\/07\\\/qpcr-basic41-title.jpg\",\"keywords\":[\"\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\"],\"articleSection\":[\"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023\"],\"inLanguage\":\"ja\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/qpcr-basic41\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/qpcr-basic41\\\/\",\"url\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/qpcr-basic41\\\/\",\"name\":\"\u86cd\u5149\u30b7\u30b0\u30ca\u30eb\u306b\u5909\u52d5\u3092\u8d77\u3053\u3059\u539f\u56e0\u3068\u306f\uff1f \u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u306b\u304a\u3051\u308b\u5149\u5b66\u7684\u5909\u52d5 - Learning at the Bench\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/qpcr-basic41\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/qpcr-basic41\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2019\\\/07\\\/qpcr-basic41-title.jpg\",\"datePublished\":\"2017-03-23T00:00:00+00:00\",\"dateModified\":\"2025-04-16T06:22:38+00:00\",\"author\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#\\\/schema\\\/person\\\/201e6a5abb838fa34e8ff0174b015d36\"},\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/qpcr-basic41\\\/#breadcrumb\"},\"inLanguage\":\"ja\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/qpcr-basic41\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"ja\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/qpcr-basic41\\\/#primaryimage\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2019\\\/07\\\/qpcr-basic41-title.jpg\",\"contentUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2019\\\/07\\\/qpcr-basic41-title.jpg\",\"width\":1200,\"height\":630,\"caption\":\"qpcr-basic41-title\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/qpcr-basic41\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"\u86cd\u5149\u30b7\u30b0\u30ca\u30eb\u306b\u5909\u52d5\u3092\u8d77\u3053\u3059\u539f\u56e0\u3068\u306f\uff1f \u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u306b\u304a\u3051\u308b\u5149\u5b66\u7684\u5909\u52d5\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#website\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/\",\"name\":\"Learning at the Bench\",\"description\":\"\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"ja\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#\\\/schema\\\/person\\\/201e6a5abb838fa34e8ff0174b015d36\",\"name\":\"LATB Staff\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"ja\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/8803277856c8b753feb4217dff0f9953327452df1a615c3c88b2f9864efb2ddd?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/8803277856c8b753feb4217dff0f9953327452df1a615c3c88b2f9864efb2ddd?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/8803277856c8b753feb4217dff0f9953327452df1a615c3c88b2f9864efb2ddd?s=96&d=mm&r=g\",\"caption\":\"LATB Staff\"},\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/author\\\/latbstaff\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"\u86cd\u5149\u30b7\u30b0\u30ca\u30eb\u306b\u5909\u52d5\u3092\u8d77\u3053\u3059\u539f\u56e0\u3068\u306f\uff1f \u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u306b\u304a\u3051\u308b\u5149\u5b66\u7684\u5909\u52d5 - Learning at the Bench","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/qpcr-basic41\/","og_locale":"ja_JP","og_type":"article","og_title":"\u86cd\u5149\u30b7\u30b0\u30ca\u30eb\u306b\u5909\u52d5\u3092\u8d77\u3053\u3059\u539f\u56e0\u3068\u306f\uff1f \u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u306b\u304a\u3051\u308b\u5149\u5b66\u7684\u5909\u52d5","og_description":"\u3069\u306e\u3088\u3046\u306a\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u88c5\u7f6e\u306b\u304a\u3044\u3066\u3082\u3001\u9069\u6027\u306a\u6027\u80fd\u3092\u7dad\u6301\u3059\u308b\u305f\u3081\u306b\u3001\u9069\u5207\u306a\u6642\u671f\u306b\u6b63\u78ba\u306a\u88dc\u6b63\u3092\u5b9f\u884c\u3059\u308b\u3053\u3068\u304c\u6975\u3081\u3066\u91cd\u8981\u3067\u3059\u3002\u88dc\u6b63\u306b\u3088\u308a\u3001\u30c7\u30fc\u30bf\u306e\u5b8c\u5168\u6027\u304a\u3088\u3073\u4e00\u8cab\u6027\u304c\u9577\u671f\u9593\u306b\u308f\u305f\u308a\u7dad\u6301\u3055\u308c\u307e\u3059\u3002\u4eca\u56de\u306f\u88dc\u6b63\u304c\u5fc5\u8981\u306a\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u306b\u304a\u3051\u308b\u5149\u5b66\u7684\u5909\u52d5\u306b\u3064\u3044\u3066\u307e\u3068\u3081\u307e\u3057\u305f\u306e\u3067\u3054\u7d39\u4ecb\u3057\u307e\u3059\u3002","og_url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/qpcr-basic41\/","og_site_name":"Learning at the Bench","article_publisher":"https:\/\/www.facebook.com\/ThermoFisherJapan","article_published_time":"2017-03-23T00:00:00+00:00","article_modified_time":"2025-04-16T06:22:38+00:00","og_image":[{"width":1200,"height":630,"url":"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/qpcr-basic41-title.jpg","type":"image\/jpeg"}],"author":"LATB Staff","twitter_card":"summary_large_image","twitter_creator":"@ThermoFisherJP","twitter_site":"@ThermoFisherJP","twitter_misc":{"\u57f7\u7b46\u8005":"LATB Staff","\u63a8\u5b9a\u8aad\u307f\u53d6\u308a\u6642\u9593":"6\u5206"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/qpcr-basic41\/#article","isPartOf":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/qpcr-basic41\/"},"author":{"name":"LATB Staff","@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#\/schema\/person\/201e6a5abb838fa34e8ff0174b015d36"},"headline":"\u86cd\u5149\u30b7\u30b0\u30ca\u30eb\u306b\u5909\u52d5\u3092\u8d77\u3053\u3059\u539f\u56e0\u3068\u306f\uff1f \u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u306b\u304a\u3051\u308b\u5149\u5b66\u7684\u5909\u52d5","datePublished":"2017-03-23T00:00:00+00:00","dateModified":"2025-04-16T06:22:38+00:00","mainEntityOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/qpcr-basic41\/"},"wordCount":26,"commentCount":0,"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/qpcr-basic41\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/qpcr-basic41-title.jpg","keywords":["\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR"],"articleSection":["\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023"],"inLanguage":"ja","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/qpcr-basic41\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/qpcr-basic41\/","url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/qpcr-basic41\/","name":"\u86cd\u5149\u30b7\u30b0\u30ca\u30eb\u306b\u5909\u52d5\u3092\u8d77\u3053\u3059\u539f\u56e0\u3068\u306f\uff1f \u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u306b\u304a\u3051\u308b\u5149\u5b66\u7684\u5909\u52d5 - Learning at the Bench","isPartOf":{"@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/qpcr-basic41\/#primaryimage"},"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/qpcr-basic41\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/qpcr-basic41-title.jpg","datePublished":"2017-03-23T00:00:00+00:00","dateModified":"2025-04-16T06:22:38+00:00","author":{"@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#\/schema\/person\/201e6a5abb838fa34e8ff0174b015d36"},"breadcrumb":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/qpcr-basic41\/#breadcrumb"},"inLanguage":"ja","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/qpcr-basic41\/"]}]},{"@type":"ImageObject","inLanguage":"ja","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/qpcr-basic41\/#primaryimage","url":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/qpcr-basic41-title.jpg","contentUrl":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/qpcr-basic41-title.jpg","width":1200,"height":630,"caption":"qpcr-basic41-title"},{"@type":"BreadcrumbList","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/qpcr-basic41\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/"},{"@type":"ListItem","position":2,"name":"\u86cd\u5149\u30b7\u30b0\u30ca\u30eb\u306b\u5909\u52d5\u3092\u8d77\u3053\u3059\u539f\u56e0\u3068\u306f\uff1f \u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u306b\u304a\u3051\u308b\u5149\u5b66\u7684\u5909\u52d5"}]},{"@type":"WebSite","@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#website","url":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/","name":"Learning at the Bench","description":"","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"ja"},{"@type":"Person","@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#\/schema\/person\/201e6a5abb838fa34e8ff0174b015d36","name":"LATB Staff","image":{"@type":"ImageObject","inLanguage":"ja","@id":"https:\/\/secure.gravatar.com\/avatar\/8803277856c8b753feb4217dff0f9953327452df1a615c3c88b2f9864efb2ddd?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/8803277856c8b753feb4217dff0f9953327452df1a615c3c88b2f9864efb2ddd?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/8803277856c8b753feb4217dff0f9953327452df1a615c3c88b2f9864efb2ddd?s=96&d=mm&r=g","caption":"LATB Staff"},"url":"https:\/\/admin.acceleratingscience.com\/author\/latbstaff\/"}]}},"taxonomy_info":{"category":[{"value":156,"label":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023"}],"post_tag":[{"value":7,"label":"\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR"}]},"featured_image_src_large":["https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/qpcr-basic41-title-1024x538.jpg",760,399,true],"author_info":{"display_name":"LATB Staff","author_link":"https:\/\/admin.acceleratingscience.com\/author\/latbstaff\/"},"comment_info":0,"category_info":[{"term_id":156,"name":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","slug":"mol-bio","term_group":0,"term_taxonomy_id":156,"taxonomy":"category","description":"","parent":0,"count":540,"filter":"raw","meta":[],"cat_ID":156,"category_count":540,"category_description":"","cat_name":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","category_nicename":"mol-bio","category_parent":0}],"tag_info":[{"term_id":7,"name":"\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR","slug":"qpcr","term_group":0,"term_taxonomy_id":7,"taxonomy":"post_tag","description":"","parent":0,"count":91,"filter":"raw","meta":[]}],"jetpack-related-posts":[{"id":25325,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/exosome-gene-expression-ts-r-25019\/","url_meta":{"origin":723,"position":0},"title":"\u3010\u7b2c5\u56de\u3011 &#8220;RNA cargo&#8221;\u306e\u7cbe\u88fd\u3068\u5b9a\u91cf\u89e3\u6790\u300d\uff5emRNA\u306e\u5b9a\u91cf\u89e3\u6790\uff5e","author":"LatB Staff","date":"2026\u5e746\u670811\u65e5","format":false,"excerpt":"\u4eca\u56de\u306f\u3001\u30a8\u30af\u30bd\u30bd\u30fc\u30e0\uff08\u30a8\u30ad\u30bd\u30bd\u30fc\u30e0\uff09\u4e2d\u306emRNA\u306e\u5b9a\u91cf\u89e3\u6790\u306b\u3064\u3044\u3066\u8aac\u660e\u3057\u307e\u3059\u3002\u7b2c3\u56de\u3067\u30a8\u30af\u30bd\u30bd\u30fc\u30e0\u304b\u2026","rel":"","context":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","block_context":{"text":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/mol-bio\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25018_eyecatch-1.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25018_eyecatch-1.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25018_eyecatch-1.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25018_eyecatch-1.jpg?resize=700%2C400&ssl=1 2x"},"classes":[]},{"id":25247,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/exosome-gene-expression-ts-r-25018\/","url_meta":{"origin":723,"position":1},"title":"\u3010\u7b2c4\u56de\u3011&#8221;RNA cargo&#8221;\u306e\u7cbe\u88fd\u3068\u5b9a\u91cf\u89e3\u6790\uff5emiRNA\u306e\u5b9a\u91cf\u89e3\u6790\uff5e","author":"LatB Staff","date":"2026\u5e745\u670829\u65e5","format":false,"excerpt":"\u524d\u56de\uff08\u3010\u7b2c3\u56de\u3011\u201cRNA cargo\u201d\u306e\u7cbe\u88fd\u3068\u5b9a\u91cf\u89e3\u6790\uff09\u3067\u306f\u3001\u30a8\u30af\u30bd\u30bd\u30fc\u30e0 \uff08\u30a8\u30ad\u30bd\u30bd\u30fc\u30e0\uff09 \u304b\u3089\u306e\u2026","rel":"","context":"\u5206\u6790\u30fb\u6e2c\u5b9a\u95a2\u9023","block_context":{"text":"\u5206\u6790\u30fb\u6e2c\u5b9a\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/analysis\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25018_eyecatch-1.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25018_eyecatch-1.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25018_eyecatch-1.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25018_eyecatch-1.jpg?resize=700%2C400&ssl=1 2x"},"classes":[]},{"id":25565,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/exosome-antibody-ts-r-25068\/","url_meta":{"origin":723,"position":2},"title":"\u3010\u7b2c8\u56de\u3011\u30a8\u30af\u30bd\u30bd\u30fc\u30e0\u30b5\u30d6\u30bf\u30a4\u30d7\u306e\u5206\u753b\u6cd5 \uff1a \u30a6\u30a7\u30b9\u30bf\u30f3\u30d6\u30ed\u30c3\u30c8\uff0fqRT-PCR\uff0f\u30b7\u30fc\u30b1\u30f3\u30b9\u89e3\u6790\u306b\u9069\u3057\u305f\u5206\u753b\u65b9\u6cd5","author":"LatB Staff","date":"2026\u5e749\u670829\u65e5","format":false,"excerpt":"\u672c\u7a3f\u3067\u306f\u3001\u30a8\u30af\u30bd\u30bd\u30fc\u30e0\u819c\u4e0a\u306e\u7279\u5b9a\u306e\u30bf\u30f3\u30d1\u30af\u8cea\u3092\u6a19\u7684\u3068\u3057\u305f\u514d\u75ab\u5438\u7740\u6cd5\u306b\u57fa\u3065\u304f\u5206\u753b\u624b\u6cd5\u3092\u7d39\u4ecb\u3057\u307e\u3059\u3002\u30a8\u30af\u2026","rel":"","context":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","block_context":{"text":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/mol-bio\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25019_eyecatch.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25019_eyecatch.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25019_eyecatch.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25019_eyecatch.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25019_eyecatch.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25019_eyecatch.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":24545,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/digital-pcr-gene-expression-gsd-ts-sd-25082\/","url_meta":{"origin":723,"position":3},"title":"\u3010Absolute Q\u30c7\u30b8\u30bf\u30ebPCR\u30b7\u30b9\u30c6\u30e0\u306e\u6d3b\u7528\u4f8b\u3011\u30df\u30c8\u30b3\u30f3\u30c9\u30ea\u30a2DNA\u306e\u5b9a\u91cf","author":"LatB Staff","date":"2026\u5e741\u670816\u65e5","format":false,"excerpt":"Applied Biosystems\u2122 QuantStudio\u2122 Absolute Q\u2122 \u30c7\u30b8\u30bf\u30ebP\u2026","rel":"","context":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","block_context":{"text":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/mol-bio\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/12\/digital-pcr-gene-expression-gsd-ts-sd-25082_eyecatch.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/12\/digital-pcr-gene-expression-gsd-ts-sd-25082_eyecatch.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/12\/digital-pcr-gene-expression-gsd-ts-sd-25082_eyecatch.jpg?resize=525%2C300&ssl=1 1.5x"},"classes":[]},{"id":25121,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/elisa-nucleic-acid-purification-bid-ts-mbr-26017\/","url_meta":{"origin":723,"position":4},"title":"\u3044\u307e\u3055\u3089\u805e\u3051\u306a\u30444PL\u306e\u57fa\u672c\uff1a4\u30d1\u30e9\u30e1\u30fc\u30bf\u30fc\u30ed\u30b8\u30b9\u30c6\u30a3\u30c3\u30af\u3092\u308f\u304b\u308a\u3084\u3059\u304f\u89e3\u8aac","author":"LATB Staff","date":"2026\u5e745\u67087\u65e5","format":false,"excerpt":"ELISA\u306e\u691c\u91cf\u7dda\u3084\u7528\u91cf\u53cd\u5fdc\u66f2\u7dda\u3092\u4f5c\u6210\u3059\u308b\u3068\u304d\u306b\u30014\u30d1\u30e9\u30e1\u30fc\u30bf\u30fc\u30ed\u30b8\u30b9\u30c6\u30a3\u30c3\u30af\uff084PL\uff09\u30e2\u30c7\u30eb\u3092\u4f7f\u7528\u2026","rel":"","context":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","block_context":{"text":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/mol-bio\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/04\/elisa-nucleic-acid-purification-bid-ts-mbr-26017_eyecatch-1-scaled.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/04\/elisa-nucleic-acid-purification-bid-ts-mbr-26017_eyecatch-1-scaled.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/04\/elisa-nucleic-acid-purification-bid-ts-mbr-26017_eyecatch-1-scaled.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/04\/elisa-nucleic-acid-purification-bid-ts-mbr-26017_eyecatch-1-scaled.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/04\/elisa-nucleic-acid-purification-bid-ts-mbr-26017_eyecatch-1-scaled.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/04\/elisa-nucleic-acid-purification-bid-ts-mbr-26017_eyecatch-1-scaled.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":24416,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/cell-imaging-fluorescent-dye-bid-ts-mbr-25076\/","url_meta":{"origin":723,"position":5},"title":"Cell Painting Assay\u3067\u7528\u3044\u3089\u308c\u308b\u8a66\u85ac\u306b\u3064\u3044\u3066\uff08MitoTracker\u3092\u7528\u3044\u305f\u30df\u30c8\u30b3\u30f3\u30c9\u30ea\u30a2\u67d3\u8272\uff09","author":"LatB Staff","date":"2025\u5e7412\u670819\u65e5","format":false,"excerpt":"\u8fd1\u5e74\u3001\u30bb\u30eb\u30da\u30a4\u30f3\u30c6\u30a3\u30f3\u30b0\uff08Cell Painting\uff09\u3068\u3044\u3046\u30a2\u30c3\u30bb\u30a4\u65b9\u6cd5\u304c\u5e83\u307e\u308a\u3064\u3064\u3042\u308a\u307e\u3059\u3002\u4f8b\u3048\u3070\u2026","rel":"","context":"\u7d30\u80de\u57f9\u990a\u30fb\u30a4\u30e1\u30fc\u30b8\u30f3\u30b0","block_context":{"text":"\u7d30\u80de\u57f9\u990a\u30fb\u30a4\u30e1\u30fc\u30b8\u30f3\u30b0","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/cell\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/12\/cell-imaging-fluorescent-dye-bid-ts-mbr-25076_eyecatch-scaled.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/12\/cell-imaging-fluorescent-dye-bid-ts-mbr-25076_eyecatch-scaled.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/12\/cell-imaging-fluorescent-dye-bid-ts-mbr-25076_eyecatch-scaled.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/12\/cell-imaging-fluorescent-dye-bid-ts-mbr-25076_eyecatch-scaled.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/12\/cell-imaging-fluorescent-dye-bid-ts-mbr-25076_eyecatch-scaled.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/12\/cell-imaging-fluorescent-dye-bid-ts-mbr-25076_eyecatch-scaled.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]}],"jetpack_sharing_enabled":true,"amp_enabled":true,"jetpack_featured_media_url":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/qpcr-basic41-title.jpg","_links":{"self":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/posts\/723","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/users\/988"}],"replies":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/comments?post=723"}],"version-history":[{"count":0,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/posts\/723\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/media\/3327"}],"wp:attachment":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/media?parent=723"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/categories?post=723"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/tags?post=723"},{"taxonomy":"division","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/division?post=723"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}