{"id":725,"date":"2020-06-26T00:00:00","date_gmt":"2020-06-25T15:00:00","guid":{"rendered":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/altsplicing-analysis-microarray-software\/"},"modified":"2021-12-20T19:07:15","modified_gmt":"2021-12-20T10:07:15","slug":"software_ma_gsd_ts_5","status":"publish","type":"post","link":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/software_ma_gsd_ts_5\/","title":{"rendered":"\u30d5\u30ea\u30fc\u306e\u30de\u30a4\u30af\u30ed\u30a2\u30ec\u30a4\u89e3\u6790\u30bd\u30d5\u30c8\u3092\u4f7f\u3063\u3066\u9078\u629e\u7684\u30b9\u30d7\u30e9\u30a4\u30b7\u30f3\u30b0\u3092\u89e3\u6790\u3057\u3066\u307f\u3088\u3046\uff01"},"content":{"rendered":"<p>\u5f0a\u793e\u3067\u306f\u767a\u73fe\u7528\u306e\u30de\u30a4\u30af\u30ed\u30a2\u30ec\u30a4\u3068\u3057\u3066\u3055\u307e\u3056\u307e\u306a\u88fd\u54c1\u3092\u3054\u7528\u610f\u3057\u3066\u3044\u307e\u3059\u304c\u3001\u4e2d\u3067\u3082\u6b21\u4e16\u4ee3\u578b\u30de\u30a4\u30af\u30ed\u30a2\u30ec\u30a4\u306eApplied Biosystems\u2122 Clariom\u2122 D\u306f\u5727\u5012\u7684\u306a\u30d7\u30ed\u30fc\u30d6\u6570\u3067\u8ee2\u5199\u9818\u57df\u5168\u4f53\u3092\u30ab\u30d0\u30fc\u3057\u3001\u30c8\u30e9\u30f3\u30b9\u30af\u30ea\u30d7\u30c8\u30fc\u30e0\u89e3\u6790\u306b\u7d76\u5927\u306a\u5a01\u529b\u3092\u767a\u63ee\u3057\u307e\u3059\u3002<\/p>\n<p>Clariom D\u306e\u6700\u5927\u306e\u7279\u5fb4\u306e\u4e00\u3064\u306f\u30a8\u30af\u30bd\u30f3\u30b8\u30e3\u30f3\u30af\u30b7\u30e7\u30f3\u90e8\u306b\u8a2d\u8a08\u3055\u308c\u305f\u30d7\u30ed\u30fc\u30d6\u3067\u3001\u3053\u308c\u306b\u3088\u308a<strong>\u9078\u629e\u7684\u30b9\u30d7\u30e9\u30a4\u30b7\u30f3\u30b0\u3092\u9ad8\u7cbe\u5ea6\u3067\u89e3\u6790<\/strong>\u3067\u304d\u307e\u3059\u3002\u6b21\u4e16\u4ee3\u30b7\u30fc\u30b1\u30f3\u30b5\u30fc\u3092\u7528\u3044\u305fRNA-Seq\u3067\u3082\u9078\u629e\u7684\u30b9\u30d7\u30e9\u30a4\u30b7\u30f3\u30b0\u306f\u89e3\u6790\u3067\u304d\u307e\u3059\u304c\u30013\u5104\u4ee5\u4e0a\u306e\u30ea\u30fc\u30c9\u6570\u304c\u5fc5\u8981\u3068\u3082\u8a00\u308f\u308c\u3066\u304a\u308a\u3001\u89e3\u6790\u306b\u306f\u30b3\u30b9\u30c8\u3084\u624b\u9593\u304c\u304b\u304b\u308a\u307e\u3059\u3002\u6b21\u4e16\u4ee3\u578b\u30de\u30a4\u30af\u30ed\u30a2\u30ec\u30a4\u306eClariom D\u306f\u7c21\u4fbf\u304b\u3064\u4f4e\u30b3\u30b9\u30c8\u3067\u9078\u629e\u7684\u30b9\u30d7\u30e9\u30a4\u30b7\u30f3\u30b0\u89e3\u6790\u304c\u3067\u304d\u308b\u3001\u5f0a\u793e\u30a2\u30ec\u30a4\u88fd\u54c1\u306e\u30d5\u30e9\u30c3\u30b0\u30b7\u30c3\u30d7\u3068\u547c\u3076\u306b\u3075\u3055\u308f\u3057\u3044\u30a2\u30ec\u30a4\u3067\u3059\u3002<\/p>\n<p>\u3053\u3053\u3067\u306f\u3001\u5f0a\u793e\u306e\u30d5\u30ea\u30fc\u89e3\u6790\u30bd\u30d5\u30c8\u3092\u7528\u3044\u3066Clariom D\u306b\u3088\u308b\u30c7\u30fc\u30bf\u89e3\u6790\u306e\u65b9\u6cd5\u3092\u3054\u7d39\u4ecb\u3057\u307e\u3059\u3002<\/p>\n<h2>Clariom D\u30b5\u30f3\u30d7\u30eb\u30c7\u30fc\u30bf\u3067\u5165\u624b\u3057\u3088\u3046<\/h2>\n<p>\u30b5\u30f3\u30d7\u30eb\u30c7\u30fc\u30bf\u306f\u3001\u5404\u30de\u30a4\u30af\u30ed\u30a2\u30ec\u30a4\u88fd\u54c1\u306e\u30da\u30fc\u30b8\u5185\u306b\u3042\u308a\u307e\u3059\u3002<br \/>\n\u5f0a\u793e\u3067\u306f\u3001\u89e3\u6790\u30bd\u30d5\u30c8\u30a6\u30a7\u30a2\u3067\u3055\u307e\u3056\u307e\u306a\u30c7\u30fc\u30bf\u89e3\u6790\u3092\u8a66\u305b\u308b\u3088\u3046\u306b\u3001Web\u304b\u3089\u81ea\u7531\u306b\u30c0\u30a6\u30f3\u30ed\u30fc\u30c9\u3067\u304d\u308b\u30b5\u30f3\u30d7\u30eb\u30c7\u30fc\u30bf\u3092\u3054\u63d0\u4f9b\u3057\u3066\u3044\u307e\u3059\u3002<\/p>\n<p>\u306f\u3058\u3081\u306b<a href=\"https:\/\/www.thermofisher.com\/order\/catalog\/product\/902922#\/902922?CID=gsd_mic_gex_r04_jp_cp0000_pjt0000_gsd00000_0so_blg_op_awa_oc_s00_ma9_Social_LAB\" target=\"_blank\" rel=\"noopener noreferrer\">\u30d2\u30c8\u7528Clariom D<\/a>\u306e\u88fd\u54c1\u30da\u30fc\u30b8 \u3092\u958b\u304d\u307e\u3059\u3002\u306a\u304a\u3001Clariom D\u306e\u30b5\u30f3\u30d7\u30eb\u30d5\u30a1\u30a4\u30eb\u306e\u30c0\u30a6\u30f3\u30ed\u30fc\u30c9\u304b\u3089TAC\u3078\u306e\u53d6\u308a\u8fbc\u307f\u307e\u3067\u306f\u3001\u30d6\u30ed\u30b0\u300c<a href=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/software_ma_gsd_ts_2\/?CID=gsd_mic_gex_r04_jp_cp0000_pjt0000_gsd00000_0so_blg_op_awa_oc_s00_ma9_Social_LAB\" target=\"_blank\" rel=\"noopener noreferrer\">\u30d5\u30ea\u30fc\u306e\u30de\u30a4\u30af\u30ed\u30a2\u30ec\u30a4\u89e3\u6790\u30bd\u30d5\u30c8\u3092\u4f7f\u3063\u3066\u30c7\u30fc\u30bf\u3092\u53d6\u308a\u8fbc\u307f\u3001\u907a\u4f1d\u5b50\u767a\u73fe\u89e3\u6790\u3092\u306f\u3058\u3081\u3088\u3046\uff01<\/a>\u300d\u306e\u300c\u30b5\u30f3\u30d7\u30eb\u30c7\u30fc\u30bf\u3092\u30c0\u30a6\u30f3\u30ed\u30fc\u30c9\u3057\u3088\u3046 \u300d\u304b\u3089\u300cCEL\u30d5\u30a1\u30a4\u30eb\u3092\u7528\u3044\u3066\u89e3\u6790\u958b\u59cb\uff01\u300d\u307e\u3067\u3092\u53c2\u8003\u306b\u3057\u3066\u304f\u3060\u3055\u3044\u3002<\/p>\n<p>Clariom D\u306e\u30b5\u30f3\u30d7\u30eb\u30c7\u30fc\u30bf\u540d\u306f\u300cSample Data: Clariom D Human Assay\u300d\u3067\u3001Liver\u306eRep1-3\u3001Muscle\u306eRep1-3\u3001Spleen\u306eRep1-3\u3092\u3053\u306e\u30d6\u30ed\u30b0\u3067\u306f\u9078\u629e\u3057\u3066\u3044\u307e\u3059\u3002Clariom D\u306fClariom S\u3088\u308a\u3082\u30d7\u30ed\u30fc\u30d6\u6570\u304c\u591a\u3044\u305f\u3081\u3001\u89e3\u6790\u306b\u6642\u9593\u304c\u304b\u304b\u308a\u307e\u3059\u306e\u3067\u3054\u6ce8\u610f\u304f\u3060\u3055\u3044\uff08\u30d1\u30bd\u30b3\u30f3\u306e\u30b9\u30da\u30c3\u30af\u306b\u3082\u3088\u308a\u307e\u3059\u304c\u3001\u4e0b\u8a18\u306e\u4f8b\u306e\u3088\u3046\u306bN=3\u30673\u7fa4\u3060\u306830\u5206\uff5e40\u5206\u7a0b\u5ea6\u304b\u304b\u308a\u307e\u3059\uff09\u3002<br \/>\n<img loading=\"lazy\" decoding=\"async\" class=\"aligncenter size-full wp-image-7327\" src=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2017\/03\/05-01.jpg\" alt=\"\" width=\"363\" height=\"305\" srcset=\"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2017\/03\/05-01.jpg 363w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2017\/03\/05-01-300x252.jpg 300w\" sizes=\"auto, (max-width: 363px) 100vw, 363px\" \/><\/p>\n<h2>\u9078\u629e\u7684\u30b9\u30d7\u30e9\u30a4\u30b7\u30f3\u30b0\u306e\u89e3\u6790\u7d50\u679c\u3092\u898b\u3066\u307f\u3088\u3046<\/h2>\n<p>Clariom D\u306e\u89e3\u6790\u306eQC\u78ba\u8a8d\u65b9\u6cd5\u306fClariom S\u3092\u4f8b\u306b\u3057\u305f\u30d6\u30ed\u30b0\u300c<a href=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/software_ma_gsd_ts_3\/?CID=gsd_mic_gex_r04_jp_cp0000_pjt0000_gsd00000_0so_blg_op_awa_oc_s00_ma9_Social_LAB\" target=\"_blank\" rel=\"noopener noreferrer\">\u30d5\u30ea\u30fc\u306e\u30de\u30a4\u30af\u30ed\u30a2\u30ec\u30a4\u89e3\u6790\u30bd\u30d5\u30c8\u3092\u4f7f\u3063\u3066\u89e3\u6790\u30c7\u30fc\u30bf\u306b\u7570\u5e38\u304c\u306a\u3044\u304b\u78ba\u8a8d\u3057\u3066\u307f\u3088\u3046\uff01<\/a>\u300d\u3001\u907a\u4f1d\u5b50\u767a\u73fe\u89e3\u6790\u306e\u7d50\u679c\u306f\u300c<a href=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/software_ma_gsd_ts_4\/?CID=gsd_mic_gex_r04_jp_cp0000_pjt0000_gsd00000_0so_blg_op_awa_oc_s00_ma9_Social_LAB\" target=\"_blank\" rel=\"noopener noreferrer\">\u30d5\u30ea\u30fc\u306e\u30de\u30a4\u30af\u30ed\u30a2\u30ec\u30a4\u89e3\u6790\u30bd\u30d5\u30c8\u3092\u4f7f\u3063\u3066\u767a\u73fe\u89e3\u6790\u3057\u3066\u307f\u3088\u3046\uff01<\/a>\u300d\u3068\u540c\u69d8\u3067\u3059\u3002<\/p>\n<p>\u3053\u3053\u3067\u306f\u3001Clariom D\u3092\u306f\u3058\u3081\u3068\u3057\u305f\u9078\u629e\u7684\u30b9\u30d7\u30e9\u30a4\u30b7\u30f3\u30b0\u306e\u89e3\u6790\u304c\u3067\u304d\u308b\u30a2\u30ec\u30a4\u3067\u3057\u304b\u78ba\u8a8d\u3067\u304d\u306a\u3044\u300cAlt-Splice View\u300d\u306e\u898b\u65b9\u3092\u3054\u7d39\u4ecb\u3057\u307e\u3059\u3002<\/p>\n<p>Clariom D\u306e\u89e3\u6790\u7d50\u679c\u306e\u300cGene View\u300d\u306e\u53f3\u6a2a\u306b\u3001Clariom S\u306e\u89e3\u6790\u6642\u306b\u306f\u306a\u304b\u3063\u305f\u300cAlt-Splice View\u300d\u3068\u3044\u3046\u30a2\u30a4\u30b3\u30f3\u304c\u8868\u793a\u3055\u308c\u307e\u3059\u3002\u3053\u308c\u3092\u30af\u30ea\u30c3\u30af\u3057\u307e\u3059\u3002<br \/>\n<img loading=\"lazy\" decoding=\"async\" class=\"aligncenter size-full wp-image-7328\" src=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2017\/03\/05-02.jpg\" alt=\"\" width=\"437\" height=\"35\" srcset=\"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2017\/03\/05-02.jpg 437w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2017\/03\/05-02-300x24.jpg 300w\" sizes=\"auto, (max-width: 437px) 100vw, 437px\" \/>\u3059\u308b\u3068\u3001\u4e0b\u8a18\u306e\u753b\u9762\u304c\u73fe\u308c\u307e\u3059\u3002<br \/>\n<img loading=\"lazy\" decoding=\"async\" class=\"aligncenter size-full wp-image-7329\" src=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2017\/03\/05-03.jpg\" alt=\"\" width=\"793\" height=\"476\" srcset=\"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2017\/03\/05-03.jpg 793w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2017\/03\/05-03-300x180.jpg 300w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2017\/03\/05-03-768x461.jpg 768w\" sizes=\"auto, (max-width: 793px) 100vw, 793px\" \/>\u3053\u306e4\u3064\u306b\u308f\u304b\u308c\u3066\u3044\u308b\u753b\u9762\u306f\u3001\u305d\u308c\u305e\u308c\u4e0b\u56f3\u306e\u5185\u5bb9\u3092\u610f\u5473\u3057\u3066\u3044\u307e\u3059\u3002<br \/>\n<img loading=\"lazy\" decoding=\"async\" class=\"aligncenter size-full wp-image-7330\" src=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2017\/03\/05-04.jpg\" alt=\"\" width=\"856\" height=\"460\" srcset=\"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2017\/03\/05-04.jpg 856w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2017\/03\/05-04-300x161.jpg 300w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2017\/03\/05-04-768x413.jpg 768w\" sizes=\"auto, (max-width: 856px) 100vw, 856px\" \/>\u3067\u306f\u3001\u5de6\u4e0a\u306e\u300cGene Table\u300d\u304b\u3089\u898b\u3066\u3044\u304d\u307e\u3057\u3087\u3046\u3002<br \/>\n<img loading=\"lazy\" decoding=\"async\" class=\"aligncenter size-full wp-image-7331\" src=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2017\/03\/05-05.jpg\" alt=\"\" width=\"589\" height=\"359\" srcset=\"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2017\/03\/05-05.jpg 589w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2017\/03\/05-05-300x183.jpg 300w\" sizes=\"auto, (max-width: 589px) 100vw, 589px\" \/>\u5de6\u5074\u306e\u80cc\u666f\u304c\u30b0\u30ec\u30fc\u306e\u5217\u306f\u3001\u300c05_\u30d5\u30ea\u30fc\u306e\u30de\u30a4\u30af\u30ed\u30a2\u30ec\u30a4\u89e3\u6790\u30bd\u30d5\u30c8\u3092\u4f7f\u3063\u3066\u767a\u73fe\u89e3\u6790\u3057\u3066\u307f\u3088\u3046\uff01\u300d\u3067\u3054\u7d39\u4ecb\u3057\u305fGene Table\u3068\u540c\u69d8\u306e\u5185\u5bb9\u3067\u3059\u3002<br \/>\n\u53f3\u5074\u306e\u80cc\u666f\u304c\u9752\u3044\u5217\u304c\u3001Alt-Splice View\u72ec\u81ea\u306e\u5185\u5bb9\u3067\u3001\u3053\u306e\u5de6\u4e0b\u306e\u300cPSRs\/JUCs Table\u300d\u306e\u4e00\u756a\u4e0a\u306e\u884c\u306e\u5185\u5bb9\u304c\u305d\u306e\u307e\u307e\u3053\u3053\u306b\u66f8\u304b\u308c\u3066\u3044\u307e\u3059\u3002<br \/>\n\u305d\u308c\u3067\u306f\u3001\u3053\u306e\u80cc\u666f\u304c\u9752\u3044\u5217\u3092\u3082\u3046\u5c11\u3057\u8a73\u3057\u304f\u898b\u308b\u305f\u3081\u306b\u3001\u300cPSRs\/JUCs Table\u300d\u3092\u898b\u3066\u307f\u307e\u3057\u3087\u3046\u3002<br \/>\n<img loading=\"lazy\" decoding=\"async\" class=\"aligncenter size-full wp-image-7332\" src=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2017\/03\/05-06.jpg\" alt=\"\" width=\"564\" height=\"184\" srcset=\"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2017\/03\/05-06.jpg 564w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2017\/03\/05-06-300x98.jpg 300w\" sizes=\"auto, (max-width: 564px) 100vw, 564px\" \/><br \/>\n<img loading=\"lazy\" decoding=\"async\" class=\"aligncenter size-full wp-image-7344\" src=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2020\/06\/table.jpg\" alt=\"\" width=\"866\" height=\"351\" srcset=\"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2020\/06\/table.jpg 866w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2020\/06\/table-300x122.jpg 300w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2020\/06\/table-768x311.jpg 768w\" sizes=\"auto, (max-width: 866px) 100vw, 866px\" \/><br \/>\n\u4e0a\u56f3\u306e\u3088\u3046\u306b\u3001\u5404PSR\/Junction ID\u306e\u4e2d\u3067Event Score\u304c\u9ad8\u3044\u9806\u306b\u4e26\u3093\u3067\u304a\u308a\u3001Splicing Index\u304c2\u500d\u4ee5\u4e0a\u3001P-value\u304c0.05\u672a\u6e80\u3067\u30d5\u30a3\u30eb\u30bf\u30ea\u30f3\u30b0\u304c\u304b\u304b\u3063\u3066\u3044\u307e\u3059\u3002\u3064\u307e\u308a\u3001\u9078\u629e\u7684\u30b9\u30d7\u30e9\u30a4\u30b7\u30f3\u30b0\u304c\u8d77\u3053\u3063\u3066\u3044\u308b\u53ef\u80fd\u6027\u304c\u9ad8\u3044\u9806\u306b\u4e26\u3093\u3067\u3044\u308b\u3053\u3068\u306b\u306a\u308a\u307e\u3059\u3002\u306a\u304aSplicing Index\u306f\u4ee5\u4e0b\u306e\u3088\u3046\u306b\u89e3\u91c8\u3067\u304d\u307e\u3059\u3002<br \/>\nSplicing Index\u306e\u5024\u304c\u5c0f\u3055\u3044\uff1aLiver\u306b\u304a\u3044\u3066\u3001\u3053\u306e\u90e8\u5206\u306eExon\u306e\u767a\u73fe\u91cf\u304c\u4f4e\u3044<br \/>\nSplicing Index\u306e\u5024\u304c\u5927\u304d\u3044\uff1aLiver\u306b\u304a\u3044\u3066\u3001\u3053\u306e\u90e8\u5206\u306eExon\u306e\u767a\u73fe\u91cf\u304c\u9ad8\u3044<\/p>\n<h2>\u907a\u4f1d\u5b50\u540d\u3067\u691c\u7d22\u3057\u3001\u89e3\u6790\u7d50\u679c\u3092\u78ba\u8a8d\u3057\u3088\u3046<\/h2>\n<p>\u6b21\u306b\u3001\u3053\u306e\u30b5\u30f3\u30d7\u30eb\u30c7\u30fc\u30bf\u306e\u4e2d\u3067\u9078\u629e\u7684\u30b9\u30d7\u30e9\u30a4\u30b7\u30f3\u30b0\u304c\u304a\u3053\u3063\u3066\u3044\u308b\u4f8b\u3068\u3057\u3066\u3001Annexin A7\u3092\u898b\u3066\u307f\u308b\u3053\u3068\u306b\u3057\u307e\u3057\u3087\u3046\u3002Gene Table\u306e\u4e0b\u90e8\u306b\u3042\u308b\u691c\u7d22\u30dc\u30c3\u30af\u30b9\u306b\u3001\u300cANXA7\u300d\u3068\u5165\u529b\u3057\u3066\u304f\u3060\u3055\u3044\u3002<br \/>\n<img loading=\"lazy\" decoding=\"async\" class=\"aligncenter size-full wp-image-7333\" src=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2017\/03\/05-07.jpg\" alt=\"\" width=\"246\" height=\"405\" srcset=\"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2017\/03\/05-07.jpg 246w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2017\/03\/05-07-182x300.jpg 182w\" sizes=\"auto, (max-width: 246px) 100vw, 246px\" \/>\u305d\u3046\u3059\u308b\u3068\u3001\u53f3\u4e0a\u306e\u56f3\u3001\u53f3\u4e0b\u306e\u56f3\u3001\u5de6\u4e0b\u306e\u8868\u306e\u8868\u793a\u304c\u5909\u308f\u308a\u3001\u3053\u306e4\u3064\u306e\u56f3\u3084\u8868\u306f\u3059\u3079\u3066\u9023\u52d5\u3057\u3066\u3044\u308b\u306e\u304c\u308f\u304b\u308a\u307e\u3059\u3002<br \/>\n<img loading=\"lazy\" decoding=\"async\" class=\"aligncenter size-full wp-image-7334\" src=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2017\/03\/05-08.jpg\" alt=\"\" width=\"648\" height=\"350\" srcset=\"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2017\/03\/05-08.jpg 648w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2017\/03\/05-08-300x162.jpg 300w\" sizes=\"auto, (max-width: 648px) 100vw, 648px\" \/>\u3053\u306eAnnexin A7\u306e\u300cPSRs\/JUCs Table\u300d\u306eSplicing Index\u306b\u7740\u76ee\u3057\u3066\u307f\u307e\u3057\u3087\u3046\u3002\u4e0b\u56f3\u306e\u3088\u3046\u306b\u3001\u4e00\u756a\u4e0a\u306ePSR\u306eSplicing Index\u304c\u98db\u3073\u629c\u3051\u3066\u5c0f\u3055\u3044\u5024\u3092\u793a\u3057\u3066\u3044\u308b\u3053\u3068\u304c\u5206\u304b\u308a\u307e\u3059\u3002<br \/>\n\u3053\u308c\u306f\u3001Liver\u306b\u304a\u3044\u3066\u3053\u306e\u30a8\u30af\u30bd\u30f3\u9818\u57df\u306e\u767a\u73fe\u304c\u6975\u3081\u3066\u4f4e\u3044\u3053\u3068\u3092\u610f\u5473\u3057\u3066\u3044\u307e\u3059\u3002<br \/>\n<img loading=\"lazy\" decoding=\"async\" class=\"aligncenter size-full wp-image-7335\" src=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2017\/03\/05-09.jpg\" alt=\"\" width=\"583\" height=\"153\" srcset=\"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2017\/03\/05-09.jpg 583w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2017\/03\/05-09-300x79.jpg 300w\" sizes=\"auto, (max-width: 583px) 100vw, 583px\" \/>\u3067\u306f\u6b21\u306b\u3001\u53f3\u4e0a\u306e\u300cAlt-Splice Visualization\u300d\u3092\u898b\u3066\u307f\u307e\u3057\u3087\u3046\u3002<br \/>\n\u307e\u305a\u3001\u7fa4\u540dLiver\u3068Muscle\u306e\u5de6\u6a2a\u306e\u25a1\u306b\u30c1\u30a7\u30c3\u30af\u3092\u5165\u308c\u3066\u304f\u3060\u3055\u3044\u3002<br \/>\n<img loading=\"lazy\" decoding=\"async\" class=\"aligncenter size-full wp-image-7323\" src=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2017\/03\/05-10.jpg\" alt=\"\" width=\"408\" height=\"140\" srcset=\"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2017\/03\/05-10.jpg 408w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2017\/03\/05-10-300x103.jpg 300w\" sizes=\"auto, (max-width: 408px) 100vw, 408px\" \/>\u4e0b\u56f3\u306e\u3088\u3046\u306b\u3001Liver\u3068Muscle\u30b5\u30f3\u30d7\u30eb\u306e\u5404\u30a8\u30af\u30bd\u30f3\u306e\u767a\u73fe\u91cf\u304c\u8868\u793a\u3055\u308c\u307e\u3057\u305f\u3002\u9752\u306f\u767a\u73fe\u91cf\u304c\u591a\u304f\u3001\u9ec4\u8272\u306f\u767a\u73fe\u91cf\u304c\u5c0f\u3055\u3044\u3053\u3068\u3092\u610f\u5473\u3057\u3066\u3044\u307e\u3059\u3002<br \/>\n<img loading=\"lazy\" decoding=\"async\" class=\"aligncenter size-full wp-image-7324\" src=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2017\/03\/05-11.jpg\" alt=\"\" width=\"639\" height=\"211\" srcset=\"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2017\/03\/05-11.jpg 639w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2017\/03\/05-11-300x99.jpg 300w\" sizes=\"auto, (max-width: 639px) 100vw, 639px\" \/>\u4e0a\u56f3\u3067\u306f\u9078\u629e\u3055\u308c\u3066\u3044\u308b\u30a8\u30af\u30bd\u30f3\u9818\u57df\u306b\u304a\u3044\u3066\u3001Liver\u3067\u306f\u9ec4\u8272\uff08\uff1d\u767a\u73fe\u91cf\u304c\u5c0f\u3055\u3044\uff09\u3001Muscle\u3067\u306f\u9752\u8272\uff08\uff1d\u767a\u73fe\u91cf\u304c\u5927\u304d\u3044\uff09\u306b\u8868\u793a\u3055\u308c\u3066\u3044\u307e\u3059\u3002\u4e0b\u56f3\u306e\u4e00\u756a\u4e0b\u306e\u30b0\u30e9\u30d5\u3067\u306f\u3001Splicing Index\u3054\u3068\u306b\u8272\u5206\u3051\u3055\u308c\u3066\u3044\u307e\u3059\u304c\u3001\u3053\u306e\u9078\u629e\u3055\u308c\u3066\u3044\u308b\u5834\u6240\u306fSplicing Index\u304c-112.98\u3068\u3001\u7d76\u5bfe\u5024\u304c\u975e\u5e38\u306b\u9ad8\u304f\u3001<strong>\u9078\u629e\u7684\u30b9\u30d7\u30e9\u30a4\u30b7\u30f3\u30b0\u304c\u8d77\u3053\u3063\u3066\u3044\u308b\u53ef\u80fd\u6027\u304c\u9ad8\u3044<\/strong>\u3053\u3068\u304c\u63a8\u6e2c\u3055\u308c\u307e\u3059\u3002<br \/>\n<img loading=\"lazy\" decoding=\"async\" class=\"aligncenter size-full wp-image-7325\" src=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2017\/03\/05-12.jpg\" alt=\"\" width=\"720\" height=\"383\" srcset=\"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2017\/03\/05-12.jpg 720w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2017\/03\/05-12-300x160.jpg 300w\" sizes=\"auto, (max-width: 720px) 100vw, 720px\" \/>\u4e0a\u56f3\u3067\u306f\u9078\u629e\u3055\u308c\u3066\u3044\u308b\u30a8\u30af\u30bd\u30f3\u9818\u57df\u306b\u304a\u3044\u3066\u3001Liver\u3067\u306f\u9ec4\u8272\uff08\uff1d\u767a\u73fe\u91cf\u304c\u5c0f\u3055\u3044\uff09\u3001Muscle\u3067\u306f\u9752\u8272\uff08\uff1d\u767a\u73fe\u91cf\u304c\u5927\u304d\u3044\uff09\u306b\u8868\u793a\u3055\u308c\u3066\u3044\u307e\u3059\u3002\u4e0b\u56f3\u306e\u4e00\u756a\u4e0b\u306e\u30b0\u30e9\u30d5\u3067\u306f\u3001Splicing Index\u3054\u3068\u306b\u8272\u5206\u3051\u304c\u3055\u308c\u3066\u3044\u307e\u3059\u304c\u3001\u3053\u306e\u9078\u629e\u3055\u308c\u3066\u3044\u308b\u5834\u6240\u306fSplicing Index\u304c-112.98\u3068\u3001\u7d76\u5bfe\u5024\u304c\u975e\u5e38\u306b\u9ad8\u304f\u3001\u9078\u629e\u7684\u30b9\u30d7\u30e9\u30a4\u30b7\u30f3\u30b0\u304c\u751f\u3058\u3066\u3044\u308b\u8208\u5473\u6df1\u3044\u4f8b\u3068\u3044\u3048\u308b\u3067\u3057\u3087\u3046\u3002<\/p>\n<p>\u6b21\u306b\u3001\u30d3\u30e5\u30fc\u30ef\u30fc\u4e0b\u90e8\u306b\u3042\u308bGenomic View\u306b\u7740\u76ee\u3057\u3066\u307f\u307e\u3057\u3087\u3046\u3002<br \/>\n<img loading=\"lazy\" decoding=\"async\" class=\"aligncenter size-full wp-image-7326\" src=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2017\/03\/05-13.jpg\" alt=\"\" width=\"800\" height=\"301\" srcset=\"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2017\/03\/05-13.jpg 800w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2017\/03\/05-13-300x113.jpg 300w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2017\/03\/05-13-768x289.jpg 768w\" sizes=\"auto, (max-width: 800px) 100vw, 800px\" \/><br \/>\n\u3053\u3053\u306b\u306f\u5404\u7a2e\u30c7\u30fc\u30bf\u30d9\u30fc\u30b9\u3088\u308a\u53ce\u96c6\u3057\u305f\u8ee2\u5199\u7523\u7269\u30a2\u30a4\u30bd\u30d5\u30a9\u30fc\u30e0\u304c\u5217\u6319\u3055\u308c\u3066\u3044\u307e\u3059\u3002\u5404\u30b9\u30d7\u30e9\u30a4\u30b9\u30d0\u30ea\u30a2\u30f3\u30c8\u306e\u3046\u3061\u3001Liver\u3067\u767a\u73fe\u3057\u3066\u3044\u308b\u53ef\u80fd\u6027\u306e\u9ad8\u3044\u30a2\u30a4\u30bd\u30d5\u30a9\u30fc\u30e0\u306f\u4e0a\u90e8\u306b\u3001Muscle\u306e\u53ef\u80fd\u6027\u304c\u9ad8\u3044\u3082\u306e\u306f\u4e0b\u90e8\u306b\u306a\u308b\u3088\u3046\u306b\u4e26\u3093\u3067\u3044\u307e\u3059\u3002<\/p>\n<p>\u3053\u306e\u3088\u3046\u306b\u3057\u3066\u3001\u3069\u306e\u3088\u3046\u306a\u30b9\u30d7\u30e9\u30a4\u30b9\u30d0\u30ea\u30a2\u30f3\u30c8\u304c\u5404\u30b5\u30f3\u30d7\u30eb\u3067\u767a\u73fe\u3057\u3066\u3044\u308b\u304b\u306e\u4e88\u60f3\u3092\u7acb\u3066\u308b\u3053\u3068\u304c\u3067\u304d\u307e\u3059\u3002<\/p>\n<h2>\u307e\u3068\u3081<\/h2>\n<p>\u4eca\u56de\u306f\u30de\u30a4\u30af\u30ed\u30a2\u30ec\u30a4\u306e\u89e3\u6790\u7528\u30bd\u30d5\u30c8\u30a6\u30a7\u30a2TAC\uff08Applied Biosystems\u2122 Transcriptome Analysis Console\uff09\u3092\u7528\u3044\u3066\u3001\u9078\u629e\u7684\u30b9\u30d7\u30e9\u30a4\u30b7\u30f3\u30b0\u306e\u89e3\u6790\u65b9\u6cd5\u306b\u3064\u3044\u3066\u7c21\u5358\u306b\u3054\u7d39\u4ecb\u3057\u307e\u3057\u305f\u3002<\/p>\n<p>TAC\u3067\u306f\u30b7\u30f3\u30d7\u30eb\u306a\u767a\u73fe\u89e3\u6790\u3060\u3051\u3067\u306a\u304f\u3001\u9078\u629e\u7684\u30b9\u30d7\u30e9\u30a4\u30b7\u30f3\u30b0\u306e\u3088\u3046\u306a\u9ad8\u5ea6\u306a\u89e3\u6790\u3082\u6975\u3081\u3066\u7c21\u5358\u306b\u884c\u3046\u3053\u3068\u304c\u3067\u304d\u307e\u3059\u3002\u9078\u629e\u7684\u30b9\u30d7\u30e9\u30a4\u30b7\u30f3\u30b0\u306b\u3088\u308b\u30d0\u30a4\u30aa\u30de\u30fc\u30ab\u30fc\u63a2\u7d22\u306a\u3069\u3092\u3054\u691c\u8a0e\u306e\u65b9\u306f\u3001\u662f\u975e\u3068\u3082TAC\u306b\u3088\u308b\u89e3\u6790\u3092\u4f53\u9a13\u3057\u3066\u307f\u3066\u304f\u3060\u3055\u3044\u3002<\/p>\n<h2>\u30de\u30a4\u30af\u30ed\u30a2\u30ec\u30a4\u306e\u624b\u5f15\u304d<\/h2>\n<p>DNA\u30de\u30a4\u30af\u30ed\u30a2\u30ec\u30a4\u306f\u767b\u5834\u3057\u3066\u304b\u3089\u3059\u3067\u306b20\u5e74\u304c\u7d4c\u3061\u3001\u540c\u3058\u3088\u3046\u306b\u7db2\u7f85\u7684\u306a\u767a\u73fe\u89e3\u6790\u304c\u51fa\u6765\u308b\u6b21\u4e16\u4ee3\u30b7\u30fc\u30b1\u30f3\u30b5\u30fc\u306e\u666e\u53ca\u3082\u3042\u3063\u3066\u3001\u719f\u6210\u3057\u305f\u6280\u8853\u3068\u8a00\u3048\u307e\u3059\u3002\u3057\u304b\u3057\u30de\u30a4\u30af\u30ed\u30a2\u30ec\u30a4\u306f\u6b21\u4e16\u4ee3\u30b7\u30fc\u30b1\u30f3\u30b5\u30fc\u306b\u6bd4\u3079\u3066\u30b3\u30b9\u30c8\u7684\u306a\u30e1\u30ea\u30c3\u30c8\u304c\u3042\u308a\u3001\u307e\u305f\u89e3\u6790\u306e\u5bb9\u6613\u3055\u306a\u3069\u304b\u3089\u3001\u307e\u3060\u307e\u3060\u5f37\u529b\u306a\u7db2\u7f85\u7684\u306a\u907a\u4f1d\u5b50\u767a\u73fe\u89e3\u6790\u304c\u51fa\u6765\u308b\u6280\u8853\u3068\u3057\u3066\u3001\u8fd1\u5e74\u898b\u76f4\u3055\u308c\u3066\u6765\u3066\u3044\u308b\u6280\u8853\u3067\u3082\u3042\u308a\u307e\u3059\u3002<br \/>\n\u3053\u306e\u624b\u5f15\u304d\u306f\u305d\u306e\u30de\u30a4\u30af\u30ed\u30a2\u30ec\u30a4\u306e\u539f\u7406\u3084\u57fa\u790e\u3001\u30ef\u30fc\u30af\u30d5\u30ed\u30fc\u306a\u3069\u306b\u3064\u3044\u3066\u5b66\u3079\u308b\u30da\u30fc\u30b8\u3067\u3059\u3002<\/p>\n<p><a class=\"btn btn-red\" href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/life-science\/microarray-analysis\/microarray-education.html?CID=gsd_mic_gex_r04_jp_cp0000_pjt0000_gsd00000_0so_blg_op_awa_oc_s00_ma9_Social_LAB\" target=\"_blank\" rel=\"noopener noreferrer\">\u8a73\u7d30\u3092\u898b\u308b<\/a><\/p>\n<p>&nbsp;<\/p>\n<p>\u7814\u7a76\u7528\u306b\u306e\u307f\u4f7f\u7528\u3067\u304d\u307e\u3059\u3002\u8a3a\u65ad\u7528\u306b\u306f\u4f7f\u7528\u3044\u305f\u3060\u3051\u307e\u305b\u3093\u3002<\/p>\n","protected":false},"excerpt":{"rendered":"<p>\u5f0a\u793e\u3067\u306f\u767a\u73fe\u7528\u306e\u30de\u30a4\u30af\u30ed\u30a2\u30ec\u30a4\u3068\u3057\u3066\u69d8\u3005\u306a\u88fd\u54c1\u3092\u3054\u7528\u610f\u3057\u3066\u3044\u307e\u3059\u304c\u3001\u4e2d\u3067\u3082\u6b21\u4e16\u4ee3\u578b\u30de\u30a4\u30af\u30ed\u30a2\u30ec\u30a4\u306eClariom D\u306f\u5727\u5012\u7684\u306a\u30d7\u30ed\u30fc\u30d6\u6570\u3067\u8ee2\u5199\u9818\u57df\u5168\u4f53\u3092\u30ab\u30d0\u30fc\u3057\u3001\u30c8\u30e9\u30f3\u30b9\u30af\u30ea\u30d7\u30c8\u30fc\u30e0\u89e3\u6790\u306b\u7d76\u5927\u306a\u5a01\u529b\u3092\u767a\u63ee\u3057\u307e\u3059\u3002\u4eca\u56de\u306f\u3001\u5f0a\u793e\u306e\u30d5\u30ea\u30fc\u89e3\u6790\u30bd\u30d5\u30c8\u3092\u7528\u3044\u3066Clariom D\u306b\u3088\u308b\u30c7\u30fc\u30bf\u89e3\u6790\u306e\u65b9\u6cd5\u3092\u3054\u7d39\u4ecb\u3057\u305f\u3044\u3068\u601d\u3044\u307e\u3059\u3002<\/p>\n","protected":false},"author":988,"featured_media":3381,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_monsterinsights_skip_tracking":false,"_genesis_hide_title":false,"_genesis_hide_breadcrumbs":false,"_genesis_hide_singular_image":false,"_genesis_hide_footer_widgets":false,"_genesis_custom_body_class":"","_genesis_custom_post_class":"","_genesis_layout":"","_jetpack_newsletter_access":"","_jetpack_dont_email_post_to_subs":false,"_jetpack_newsletter_tier_id":0,"_jetpack_memberships_contains_paywalled_content":false,"_jetpack_hide_featured_image":false,"_jetpack_featured_image_duplicate_dismissed":0,"_jetpack_feature_clip_id":0,"_jetpack_memberships_contains_paid_content":false,"footnotes":"","jetpack_post_was_ever_published":false},"categories":[156],"tags":[71],"division":[],"class_list":["post-725","post","type-post","status-publish","format-standard","has-post-thumbnail","category-mol-bio","tag-microarray","entry"],"_selected_authors":"","_selected_reviewers":"","acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v28.9 (Yoast SEO v28.9) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>\u30d5\u30ea\u30fc\u306e\u30de\u30a4\u30af\u30ed\u30a2\u30ec\u30a4\u89e3\u6790\u30bd\u30d5\u30c8\u3092\u4f7f\u3063\u3066\u9078\u629e\u7684\u30b9\u30d7\u30e9\u30a4\u30b7\u30f3\u30b0\u3092\u89e3\u6790\u3057\u3066\u307f\u3088\u3046\uff01 - Learning at the Bench<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/software_ma_gsd_ts_5\/\" \/>\n<meta property=\"og:locale\" content=\"ja_JP\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"\u30d5\u30ea\u30fc\u306e\u30de\u30a4\u30af\u30ed\u30a2\u30ec\u30a4\u89e3\u6790\u30bd\u30d5\u30c8\u3092\u4f7f\u3063\u3066\u9078\u629e\u7684\u30b9\u30d7\u30e9\u30a4\u30b7\u30f3\u30b0\u3092\u89e3\u6790\u3057\u3066\u307f\u3088\u3046\uff01\" \/>\n<meta property=\"og:description\" content=\"\u5f0a\u793e\u3067\u306f\u767a\u73fe\u7528\u306e\u30de\u30a4\u30af\u30ed\u30a2\u30ec\u30a4\u3068\u3057\u3066\u69d8\u3005\u306a\u88fd\u54c1\u3092\u3054\u7528\u610f\u3057\u3066\u3044\u307e\u3059\u304c\u3001\u4e2d\u3067\u3082\u6b21\u4e16\u4ee3\u578b\u30de\u30a4\u30af\u30ed\u30a2\u30ec\u30a4\u306eClariom D\u306f\u5727\u5012\u7684\u306a\u30d7\u30ed\u30fc\u30d6\u6570\u3067\u8ee2\u5199\u9818\u57df\u5168\u4f53\u3092\u30ab\u30d0\u30fc\u3057\u3001\u30c8\u30e9\u30f3\u30b9\u30af\u30ea\u30d7\u30c8\u30fc\u30e0\u89e3\u6790\u306b\u7d76\u5927\u306a\u5a01\u529b\u3092\u767a\u63ee\u3057\u307e\u3059\u3002\u4eca\u56de\u306f\u3001\u5f0a\u793e\u306e\u30d5\u30ea\u30fc\u89e3\u6790\u30bd\u30d5\u30c8\u3092\u7528\u3044\u3066Clariom D\u306b\u3088\u308b\u30c7\u30fc\u30bf\u89e3\u6790\u306e\u65b9\u6cd5\u3092\u3054\u7d39\u4ecb\u3057\u305f\u3044\u3068\u601d\u3044\u307e\u3059\u3002\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/software_ma_gsd_ts_5\/\" \/>\n<meta property=\"og:site_name\" content=\"Learning at the Bench\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/ThermoFisherJapan\" \/>\n<meta property=\"article:published_time\" content=\"2020-06-25T15:00:00+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2021-12-20T10:07:15+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/free-software-for-microarray-title-5.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"1200\" \/>\n\t<meta property=\"og:image:height\" content=\"624\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"LATB Staff\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:creator\" content=\"@ThermoFisherJP\" \/>\n<meta name=\"twitter:site\" content=\"@ThermoFisherJP\" \/>\n<meta name=\"twitter:label1\" content=\"\u57f7\u7b46\u8005\" \/>\n\t<meta name=\"twitter:data1\" content=\"LATB Staff\" \/>\n\t<meta name=\"twitter:label2\" content=\"\u63a8\u5b9a\u8aad\u307f\u53d6\u308a\u6642\u9593\" \/>\n\t<meta name=\"twitter:data2\" content=\"1\u5206\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/software_ma_gsd_ts_5\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/software_ma_gsd_ts_5\\\/\"},\"author\":{\"name\":\"LATB Staff\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#\\\/schema\\\/person\\\/201e6a5abb838fa34e8ff0174b015d36\"},\"headline\":\"\u30d5\u30ea\u30fc\u306e\u30de\u30a4\u30af\u30ed\u30a2\u30ec\u30a4\u89e3\u6790\u30bd\u30d5\u30c8\u3092\u4f7f\u3063\u3066\u9078\u629e\u7684\u30b9\u30d7\u30e9\u30a4\u30b7\u30f3\u30b0\u3092\u89e3\u6790\u3057\u3066\u307f\u3088\u3046\uff01\",\"datePublished\":\"2020-06-25T15:00:00+00:00\",\"dateModified\":\"2021-12-20T10:07:15+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/software_ma_gsd_ts_5\\\/\"},\"wordCount\":139,\"commentCount\":0,\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/software_ma_gsd_ts_5\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2019\\\/07\\\/free-software-for-microarray-title-5.jpg\",\"keywords\":[\"\u30de\u30a4\u30af\u30ed\u30a2\u30ec\u30a4\"],\"articleSection\":[\"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023\"],\"inLanguage\":\"ja\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/software_ma_gsd_ts_5\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/software_ma_gsd_ts_5\\\/\",\"url\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/software_ma_gsd_ts_5\\\/\",\"name\":\"\u30d5\u30ea\u30fc\u306e\u30de\u30a4\u30af\u30ed\u30a2\u30ec\u30a4\u89e3\u6790\u30bd\u30d5\u30c8\u3092\u4f7f\u3063\u3066\u9078\u629e\u7684\u30b9\u30d7\u30e9\u30a4\u30b7\u30f3\u30b0\u3092\u89e3\u6790\u3057\u3066\u307f\u3088\u3046\uff01 - Learning at the Bench\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/software_ma_gsd_ts_5\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/software_ma_gsd_ts_5\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2019\\\/07\\\/free-software-for-microarray-title-5.jpg\",\"datePublished\":\"2020-06-25T15:00:00+00:00\",\"dateModified\":\"2021-12-20T10:07:15+00:00\",\"author\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#\\\/schema\\\/person\\\/201e6a5abb838fa34e8ff0174b015d36\"},\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/software_ma_gsd_ts_5\\\/#breadcrumb\"},\"inLanguage\":\"ja\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/software_ma_gsd_ts_5\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"ja\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/software_ma_gsd_ts_5\\\/#primaryimage\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2019\\\/07\\\/free-software-for-microarray-title-5.jpg\",\"contentUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2019\\\/07\\\/free-software-for-microarray-title-5.jpg\",\"width\":1200,\"height\":624,\"caption\":\"free-software-for-microarray-title\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/software_ma_gsd_ts_5\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"\u30d5\u30ea\u30fc\u306e\u30de\u30a4\u30af\u30ed\u30a2\u30ec\u30a4\u89e3\u6790\u30bd\u30d5\u30c8\u3092\u4f7f\u3063\u3066\u9078\u629e\u7684\u30b9\u30d7\u30e9\u30a4\u30b7\u30f3\u30b0\u3092\u89e3\u6790\u3057\u3066\u307f\u3088\u3046\uff01\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#website\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/\",\"name\":\"Learning at the Bench\",\"description\":\"\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"ja\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#\\\/schema\\\/person\\\/201e6a5abb838fa34e8ff0174b015d36\",\"name\":\"LATB Staff\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"ja\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/8803277856c8b753feb4217dff0f9953327452df1a615c3c88b2f9864efb2ddd?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/8803277856c8b753feb4217dff0f9953327452df1a615c3c88b2f9864efb2ddd?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/8803277856c8b753feb4217dff0f9953327452df1a615c3c88b2f9864efb2ddd?s=96&d=mm&r=g\",\"caption\":\"LATB Staff\"},\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/author\\\/latbstaff\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"\u30d5\u30ea\u30fc\u306e\u30de\u30a4\u30af\u30ed\u30a2\u30ec\u30a4\u89e3\u6790\u30bd\u30d5\u30c8\u3092\u4f7f\u3063\u3066\u9078\u629e\u7684\u30b9\u30d7\u30e9\u30a4\u30b7\u30f3\u30b0\u3092\u89e3\u6790\u3057\u3066\u307f\u3088\u3046\uff01 - Learning at the Bench","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/software_ma_gsd_ts_5\/","og_locale":"ja_JP","og_type":"article","og_title":"\u30d5\u30ea\u30fc\u306e\u30de\u30a4\u30af\u30ed\u30a2\u30ec\u30a4\u89e3\u6790\u30bd\u30d5\u30c8\u3092\u4f7f\u3063\u3066\u9078\u629e\u7684\u30b9\u30d7\u30e9\u30a4\u30b7\u30f3\u30b0\u3092\u89e3\u6790\u3057\u3066\u307f\u3088\u3046\uff01","og_description":"\u5f0a\u793e\u3067\u306f\u767a\u73fe\u7528\u306e\u30de\u30a4\u30af\u30ed\u30a2\u30ec\u30a4\u3068\u3057\u3066\u69d8\u3005\u306a\u88fd\u54c1\u3092\u3054\u7528\u610f\u3057\u3066\u3044\u307e\u3059\u304c\u3001\u4e2d\u3067\u3082\u6b21\u4e16\u4ee3\u578b\u30de\u30a4\u30af\u30ed\u30a2\u30ec\u30a4\u306eClariom D\u306f\u5727\u5012\u7684\u306a\u30d7\u30ed\u30fc\u30d6\u6570\u3067\u8ee2\u5199\u9818\u57df\u5168\u4f53\u3092\u30ab\u30d0\u30fc\u3057\u3001\u30c8\u30e9\u30f3\u30b9\u30af\u30ea\u30d7\u30c8\u30fc\u30e0\u89e3\u6790\u306b\u7d76\u5927\u306a\u5a01\u529b\u3092\u767a\u63ee\u3057\u307e\u3059\u3002\u4eca\u56de\u306f\u3001\u5f0a\u793e\u306e\u30d5\u30ea\u30fc\u89e3\u6790\u30bd\u30d5\u30c8\u3092\u7528\u3044\u3066Clariom D\u306b\u3088\u308b\u30c7\u30fc\u30bf\u89e3\u6790\u306e\u65b9\u6cd5\u3092\u3054\u7d39\u4ecb\u3057\u305f\u3044\u3068\u601d\u3044\u307e\u3059\u3002","og_url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/software_ma_gsd_ts_5\/","og_site_name":"Learning at the Bench","article_publisher":"https:\/\/www.facebook.com\/ThermoFisherJapan","article_published_time":"2020-06-25T15:00:00+00:00","article_modified_time":"2021-12-20T10:07:15+00:00","og_image":[{"width":1200,"height":624,"url":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/free-software-for-microarray-title-5.jpg","type":"image\/jpeg"}],"author":"LATB Staff","twitter_card":"summary_large_image","twitter_creator":"@ThermoFisherJP","twitter_site":"@ThermoFisherJP","twitter_misc":{"\u57f7\u7b46\u8005":"LATB Staff","\u63a8\u5b9a\u8aad\u307f\u53d6\u308a\u6642\u9593":"1\u5206"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/software_ma_gsd_ts_5\/#article","isPartOf":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/software_ma_gsd_ts_5\/"},"author":{"name":"LATB Staff","@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#\/schema\/person\/201e6a5abb838fa34e8ff0174b015d36"},"headline":"\u30d5\u30ea\u30fc\u306e\u30de\u30a4\u30af\u30ed\u30a2\u30ec\u30a4\u89e3\u6790\u30bd\u30d5\u30c8\u3092\u4f7f\u3063\u3066\u9078\u629e\u7684\u30b9\u30d7\u30e9\u30a4\u30b7\u30f3\u30b0\u3092\u89e3\u6790\u3057\u3066\u307f\u3088\u3046\uff01","datePublished":"2020-06-25T15:00:00+00:00","dateModified":"2021-12-20T10:07:15+00:00","mainEntityOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/software_ma_gsd_ts_5\/"},"wordCount":139,"commentCount":0,"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/software_ma_gsd_ts_5\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/free-software-for-microarray-title-5.jpg","keywords":["\u30de\u30a4\u30af\u30ed\u30a2\u30ec\u30a4"],"articleSection":["\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023"],"inLanguage":"ja","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/software_ma_gsd_ts_5\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/software_ma_gsd_ts_5\/","url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/software_ma_gsd_ts_5\/","name":"\u30d5\u30ea\u30fc\u306e\u30de\u30a4\u30af\u30ed\u30a2\u30ec\u30a4\u89e3\u6790\u30bd\u30d5\u30c8\u3092\u4f7f\u3063\u3066\u9078\u629e\u7684\u30b9\u30d7\u30e9\u30a4\u30b7\u30f3\u30b0\u3092\u89e3\u6790\u3057\u3066\u307f\u3088\u3046\uff01 - Learning at the Bench","isPartOf":{"@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/software_ma_gsd_ts_5\/#primaryimage"},"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/software_ma_gsd_ts_5\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/free-software-for-microarray-title-5.jpg","datePublished":"2020-06-25T15:00:00+00:00","dateModified":"2021-12-20T10:07:15+00:00","author":{"@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#\/schema\/person\/201e6a5abb838fa34e8ff0174b015d36"},"breadcrumb":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/software_ma_gsd_ts_5\/#breadcrumb"},"inLanguage":"ja","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/software_ma_gsd_ts_5\/"]}]},{"@type":"ImageObject","inLanguage":"ja","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/software_ma_gsd_ts_5\/#primaryimage","url":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/free-software-for-microarray-title-5.jpg","contentUrl":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/free-software-for-microarray-title-5.jpg","width":1200,"height":624,"caption":"free-software-for-microarray-title"},{"@type":"BreadcrumbList","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/software_ma_gsd_ts_5\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/"},{"@type":"ListItem","position":2,"name":"\u30d5\u30ea\u30fc\u306e\u30de\u30a4\u30af\u30ed\u30a2\u30ec\u30a4\u89e3\u6790\u30bd\u30d5\u30c8\u3092\u4f7f\u3063\u3066\u9078\u629e\u7684\u30b9\u30d7\u30e9\u30a4\u30b7\u30f3\u30b0\u3092\u89e3\u6790\u3057\u3066\u307f\u3088\u3046\uff01"}]},{"@type":"WebSite","@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#website","url":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/","name":"Learning at the Bench","description":"","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"ja"},{"@type":"Person","@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#\/schema\/person\/201e6a5abb838fa34e8ff0174b015d36","name":"LATB Staff","image":{"@type":"ImageObject","inLanguage":"ja","@id":"https:\/\/secure.gravatar.com\/avatar\/8803277856c8b753feb4217dff0f9953327452df1a615c3c88b2f9864efb2ddd?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/8803277856c8b753feb4217dff0f9953327452df1a615c3c88b2f9864efb2ddd?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/8803277856c8b753feb4217dff0f9953327452df1a615c3c88b2f9864efb2ddd?s=96&d=mm&r=g","caption":"LATB Staff"},"url":"https:\/\/admin.acceleratingscience.com\/author\/latbstaff\/"}]}},"taxonomy_info":{"category":[{"value":156,"label":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023"}],"post_tag":[{"value":71,"label":"\u30de\u30a4\u30af\u30ed\u30a2\u30ec\u30a4"}]},"featured_image_src_large":["https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/free-software-for-microarray-title-5-1024x532.jpg",760,395,true],"author_info":{"display_name":"LATB Staff","author_link":"https:\/\/admin.acceleratingscience.com\/author\/latbstaff\/"},"comment_info":0,"category_info":[{"term_id":156,"name":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","slug":"mol-bio","term_group":0,"term_taxonomy_id":156,"taxonomy":"category","description":"","parent":0,"count":540,"filter":"raw","meta":[],"cat_ID":156,"category_count":540,"category_description":"","cat_name":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","category_nicename":"mol-bio","category_parent":0}],"tag_info":[{"term_id":71,"name":"\u30de\u30a4\u30af\u30ed\u30a2\u30ec\u30a4","slug":"microarray","term_group":0,"term_taxonomy_id":71,"taxonomy":"post_tag","description":"","parent":0,"count":28,"filter":"raw","meta":[]}],"jetpack-related-posts":[{"id":20152,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/exosome-nucleic-acid-purification-ts-r-25017\/","url_meta":{"origin":725,"position":0},"title":"\u3010\u7b2c3\u56de\u3011\u201cRNA cargo\u201d\u306e\u7cbe\u88fd\u3068\u5b9a\u91cf\u89e3\u6790","author":"LatB Staff","date":"2026\u5e745\u670813\u65e5","format":false,"excerpt":"\u7b2c2\u56de\u3067\u306f\u3001\u57f9\u990a\u4e0a\u6e05\u3084\u3055\u307e\u3056\u307e\u306a\u4f53\u6db2\u30b5\u30f3\u30d7\u30eb\u304b\u3089\u306e\u30a8\u30af\u30bd\u30bd\u30fc\u30e0\u306e\u6fc3\u7e2e\u30fb\u56de\u53ce\u65b9\u6cd5\u306b\u3064\u3044\u3066\u7d39\u4ecb\u3057\u307e\u3057\u305f\u304c\u2026","rel":"","context":"\u305d\u306e\u4ed6","block_context":{"text":"\u305d\u306e\u4ed6","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/else\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/f17931341a23d82235760ed66ded9c41.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/f17931341a23d82235760ed66ded9c41.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/f17931341a23d82235760ed66ded9c41.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/f17931341a23d82235760ed66ded9c41.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/f17931341a23d82235760ed66ded9c41.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/f17931341a23d82235760ed66ded9c41.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":24647,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/sanger-seq-mutational-analysis-gsd-ts-ce-26007\/","url_meta":{"origin":725,"position":1},"title":"\u30de\u30a4\u30ca\u30fc\u5909\u7570\u3092\u691c\u51fa\uff01Minor Variant Finder\u30bd\u30d5\u30c8\u30a6\u30a8\u30a2","author":"LatB Staff","date":"2026\u5e742\u67089\u65e5","format":false,"excerpt":"\u30ad\u30e3\u30d4\u30e9\u30ea\u30fc\u30b7\u30fc\u30b1\u30f3\u30b5\u3067\u306f\u300125%\u7a0b\u5ea6\u306e\u5272\u5408\u306e\u5909\u7570\u3092\u691c\u51fa\u3059\u308b\u3053\u3068\u304c\u3067\u304d\u307e\u3059\u304c\u3001\u3053\u308c\u3088\u308a\u3082\u4f4e\u3044\u5272\u5408\u306e\u5909\u2026","rel":"","context":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","block_context":{"text":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/mol-bio\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/01\/sanger-seq-mutational-analysis-gsd-ts-ce-26007_eyecatch.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/01\/sanger-seq-mutational-analysis-gsd-ts-ce-26007_eyecatch.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/01\/sanger-seq-mutational-analysis-gsd-ts-ce-26007_eyecatch.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/01\/sanger-seq-mutational-analysis-gsd-ts-ce-26007_eyecatch.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/01\/sanger-seq-mutational-analysis-gsd-ts-ce-26007_eyecatch.jpg?resize=1050%2C600&ssl=1 3x"},"classes":[]},{"id":25623,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/exosome-flow-cytometry-ts-r-25069\/","url_meta":{"origin":725,"position":2},"title":"\u3010\u7b2c9\u56de\u3011 \u30d5\u30ed\u30fc\u30b5\u30a4\u30c8\u30e1\u30c8\u30ea\u30fc\u89e3\u6790\u7528\u30a8\u30af\u30bd\u30bd\u30fc\u30e0\u30b5\u30d6\u30bf\u30a4\u30d7\u306e\u56de\u53ce","author":"LatB Staff","date":"2026\u5e7410\u670830\u65e5","format":false,"excerpt":"\u672c\u7a3f\u3067\u306f\u3001\u30ca\u30ce\u30b5\u30a4\u30ba\u306e\u5c0f\u80de\uff08\u76f4\u5f8430\uff5e100 nm\uff09\u3067\u3042\u308b\u30a8\u30af\u30bd\u30bd\u30fc\u30e0\u3092\u3001\u78c1\u6c17\u30d3\u30fc\u30ba\uff08Invitro\u2026","rel":"","context":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","block_context":{"text":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/mol-bio\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25019_eyecatch.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25019_eyecatch.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25019_eyecatch.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25019_eyecatch.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25019_eyecatch.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25019_eyecatch.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":24187,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/ngs-gene-expression-csd-ts-ion-25073\/","url_meta":{"origin":725,"position":3},"title":"\u3010\u3084\u3063\u3066\u307f\u305f\u3011\u5fae\u91cf\u30fb\u5206\u89e3RNA\u306b\u3088\u308b\u767a\u73fe\u89e3\u6790\u306e\u6700\u9069\u89e3\u306f\uff1fRNA-Seq\u3068Ion AmpliSeq Transcriptome\u3092\u6bd4\u3079\u3066\u307f\u305f","author":"LatB Staff","date":"2025\u5e7411\u670828\u65e5","format":false,"excerpt":"\u6b21\u4e16\u4ee3\u30b7\u30fc\u30b1\u30f3\u30b5\u3067\u306e\u767a\u73fe\u89e3\u6790\u306b\u53d6\u308a\u7d44\u3080\u969b\u3001RNA\u30b5\u30f3\u30d7\u30eb\u304c\u300c\u5c11\u306a\u3059\u304e\u308b\u300d\u300c\u5206\u89e3\u3057\u3066\u3044\u308b\u300d\u3068\u3044\u3046\u72b6\u6cc1\u306f\u2026","rel":"","context":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","block_context":{"text":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/mol-bio\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/11\/ngs-gene-expression-csd-ts-ion-25073_eyecatch-scaled.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/11\/ngs-gene-expression-csd-ts-ion-25073_eyecatch-scaled.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/11\/ngs-gene-expression-csd-ts-ion-25073_eyecatch-scaled.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/11\/ngs-gene-expression-csd-ts-ion-25073_eyecatch-scaled.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/11\/ngs-gene-expression-csd-ts-ion-25073_eyecatch-scaled.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/11\/ngs-gene-expression-csd-ts-ion-25073_eyecatch-scaled.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":25247,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/exosome-gene-expression-ts-r-25018\/","url_meta":{"origin":725,"position":4},"title":"\u3010\u7b2c4\u56de\u3011&#8221;RNA cargo&#8221;\u306e\u7cbe\u88fd\u3068\u5b9a\u91cf\u89e3\u6790\uff5emiRNA\u306e\u5b9a\u91cf\u89e3\u6790\uff5e","author":"LatB Staff","date":"2026\u5e745\u670829\u65e5","format":false,"excerpt":"\u524d\u56de\uff08\u3010\u7b2c3\u56de\u3011\u201cRNA cargo\u201d\u306e\u7cbe\u88fd\u3068\u5b9a\u91cf\u89e3\u6790\uff09\u3067\u306f\u3001\u30a8\u30af\u30bd\u30bd\u30fc\u30e0 \uff08\u30a8\u30ad\u30bd\u30bd\u30fc\u30e0\uff09 \u304b\u3089\u306e\u2026","rel":"","context":"\u5206\u6790\u30fb\u6e2c\u5b9a\u95a2\u9023","block_context":{"text":"\u5206\u6790\u30fb\u6e2c\u5b9a\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/analysis\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25018_eyecatch-1.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25018_eyecatch-1.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25018_eyecatch-1.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25018_eyecatch-1.jpg?resize=700%2C400&ssl=1 2x"},"classes":[]},{"id":25565,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/exosome-antibody-ts-r-25068\/","url_meta":{"origin":725,"position":5},"title":"\u3010\u7b2c8\u56de\u3011\u30a8\u30af\u30bd\u30bd\u30fc\u30e0\u30b5\u30d6\u30bf\u30a4\u30d7\u306e\u5206\u753b\u6cd5 \uff1a \u30a6\u30a7\u30b9\u30bf\u30f3\u30d6\u30ed\u30c3\u30c8\uff0fqRT-PCR\uff0f\u30b7\u30fc\u30b1\u30f3\u30b9\u89e3\u6790\u306b\u9069\u3057\u305f\u5206\u753b\u65b9\u6cd5","author":"LatB Staff","date":"2026\u5e749\u670829\u65e5","format":false,"excerpt":"\u672c\u7a3f\u3067\u306f\u3001\u30a8\u30af\u30bd\u30bd\u30fc\u30e0\u819c\u4e0a\u306e\u7279\u5b9a\u306e\u30bf\u30f3\u30d1\u30af\u8cea\u3092\u6a19\u7684\u3068\u3057\u305f\u514d\u75ab\u5438\u7740\u6cd5\u306b\u57fa\u3065\u304f\u5206\u753b\u624b\u6cd5\u3092\u7d39\u4ecb\u3057\u307e\u3059\u3002\u30a8\u30af\u2026","rel":"","context":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","block_context":{"text":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/mol-bio\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25019_eyecatch.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25019_eyecatch.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25019_eyecatch.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25019_eyecatch.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25019_eyecatch.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25019_eyecatch.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]}],"jetpack_sharing_enabled":true,"amp_enabled":true,"jetpack_featured_media_url":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/free-software-for-microarray-title-5.jpg","_links":{"self":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/posts\/725","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/users\/988"}],"replies":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/comments?post=725"}],"version-history":[{"count":0,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/posts\/725\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/media\/3381"}],"wp:attachment":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/media?parent=725"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/categories?post=725"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/tags?post=725"},{"taxonomy":"division","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/division?post=725"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}