{"id":7346,"date":"2020-06-30T13:26:53","date_gmt":"2020-06-30T04:26:53","guid":{"rendered":"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/?p=7346"},"modified":"2024-09-18T17:11:02","modified_gmt":"2024-09-18T08:11:02","slug":"fastpcr_ce_gsd_ts_1","status":"publish","type":"post","link":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/fastpcr_ce_gsd_ts_1\/","title":{"rendered":"\u5922\u306e\u6642\u9593\u77ed\u7e2e\uff01Fast\u30b5\u30a4\u30af\u30eb\u30b7\u30fc\u30b1\u30f3\u30b9\u3092\u3054\u5b58\u3058\u3067\u3059\u304b\uff1f"},"content":{"rendered":"<p>Fast PCR\u306f\u8fc5\u901f\u306b\u7d50\u679c\u3092\u51fa\u305b\u308b\u6a5f\u5668\u30fb\u8a66\u85ac\u3092\u7d44\u307f\u5408\u308f\u305b\u3066\u4f7f\u7528\u3059\u308b\u3053\u3068\u306b\u3088\u308a\u3001\u5b9f\u9a13\u6642\u9593\u3092\u5927\u5e45\u306b\u77ed\u7e2e\u3067\u304d\u308b\u6280\u8853\u3067\u3059\u3002\u3053\u306e\u6280\u8853\u306b\u3088\u308a\u3001\u300cPCR\u53cd\u5fdc\u300d\u3068\u300c\u30b5\u30a4\u30af\u30eb\u30b7\u30fc\u30b1\u30f3\u30b9\u53cd\u5fdc\u300d\u306e\u4e21\u65b9\u306e\u30e9\u30f3\u30bf\u30a4\u30e0\u3092\u5927\u5e45\u306b\u77ed\u7e2e\u3059\u308b\u3053\u3068\u304c\u3067\u304d\u307e\u3059\u3002<br \/>\n\u305d\u3053\u3067\u4eca\u56de\u306f\u3001Fast PCR\u306b\u3064\u3044\u3066\u3001\u3054\u7d39\u4ecb\u3057\u307e\u3059\u3002<\/p>\n<p>\u25bc\u3053\u3093\u306a\u65b9\u306b\u304a\u3059\u3059\u3081\u3067\u3059\uff01<br \/>\n\u30fb\u53cd\u5fdc\u306e\u5f85\u3061\u6642\u9593\u3092\u77ed\u7e2e\u3057\u305f\u3044\u3068\u601d\u3063\u3066\u3044\u308b\u65b9<br \/>\n\u30fb\u65bd\u8a2d\u306e\u30b5\u30fc\u30de\u30eb\u30b5\u30a4\u30af\u30e9\u30fc\u304cFast\u306b\u5bfe\u5fdc\u3057\u3066\u3044\u308b\u304b\u308f\u304b\u3089\u306a\u3044\u65b9<\/p>\n<h2>Fast PCR\u304c\u53ef\u80fd\u306a\u30b5\u30fc\u30de\u30eb\u30b5\u30a4\u30af\u30e9\u30fc\u304b\u78ba\u8a8d\u3057\u3066\u307f\u307e\u3057\u3087\u3046\uff01<\/h2>\n<p>\u30d6\u30ed\u30c3\u30af\u306e\u30e9\u30f3\u30d7\u30b9\u30d4\u30fc\u30c9\u304c\u9ad8\u901f\u5316\u3055\u308c\u305f\u30b5\u30fc\u30de\u30eb\u30b5\u30a4\u30af\u30e9\u30fc\u3092\u4f7f\u7528\u3059\u308b\u3053\u3068\u3067\u3001\u5404\u30b9\u30c6\u30c3\u30d7\u306e\u6e29\u5ea6\u5909\u5316\u306b\u304b\u304b\u308b\u6642\u9593\u304c\u77ed\u7e2e\u3055\u308c\u308b\u305f\u3081\u3001\u4e00\u3064\u306e\u30d7\u30ed\u30b0\u30e9\u30e0\u306b\u304b\u304b\u308b\u6642\u9593\u304c\u77ed\u304f\u306a\u308a\u307e\u3059\u3002<br \/>\n<a href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/life-science\/pcr\/thermal-cyclers-realtime-instruments\/thermal-cyclers.html?CID=gsd_cap_sbu_r04_jp_cp1349_pjt5618_gsd00000_0so_blg_op_lgn_kt_s00_dne7_Social_LAB\" target=\"_blank\" rel=\"noopener noreferrer\">Applied Biosystems\u306eFast PCR\u5bfe\u5fdc\u30b5\u30fc\u30de\u30eb\u30b5\u30a4\u30af\u30e9\u30fc\u306e\u30e9\u30a4\u30f3\u30a2\u30c3\u30d7<\/a><\/p>\n<h2>Fast PCR\u306b\u3088\u308b\u30b7\u30fc\u30b1\u30f3\u30b9\u7528PCR\u7523\u7269\u5897\u5e45\u306e\u30dd\u30a4\u30f3\u30c8<\/h2>\n<p>Fast PCR\u5bfe\u5fdc\u30b5\u30fc\u30de\u30eb\u30b5\u30a4\u30af\u30e9\u30fc\u306b\u52a0\u3048\u3001<a href=\"https:\/\/www.thermofisher.com\/order\/catalog\/product\/14000012#\/14000012?CID=gsd_cap_sbu_r04_jp_cp1349_pjt5618_gsd00000_0so_blg_op_lgn_kt_s00_dne7_Social_LAB\" target=\"_blank\" rel=\"noopener noreferrer\">Invitrogen\u2122 Platinum\u2122 II Hot-Start PCR Master Mix<\/a>\u306a\u3069\u3001PCR\u7523\u7269\u3092\u77ed\u6642\u9593\u3067\u5408\u6210\u3067\u304d\u308b\u9175\u7d20\u3092\u9078\u629e\u3059\u308b\u3053\u3068\u3067\u3001\u3055\u3089\u306a\u308b\u6642\u9593\u77ed\u7e2e\u304c\u53ef\u80fd\u306b\u306a\u308a\u307e\u3059\u3002<br \/>\n2\u3064\u306e\u30d7\u30ed\u30b0\u30e9\u30e0\u3092\u3001GC\u542b\u91cf\u3084\u3001\u4f38\u9577\u3055\u305b\u308b\u30b5\u30a4\u30ba\u306b\u3088\u3063\u3066\u4f7f\u3044\u5206\u3051\u307e\u3059\u3002<br \/>\n<img loading=\"lazy\" decoding=\"async\" class=\"aligncenter wp-image-7390 size-full\" src=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2020\/06\/fig-1-e1594020586331.jpg\" alt=\"\" width=\"500\" height=\"306\" \/><\/p>\n<p>\u307e\u305f\u3001PCR\u53cd\u5fdc\u5f8c\u306e\u7cbe\u88fd\u6cd5\u3068\u3057\u3066<a href=\"https:\/\/www.thermofisher.com\/order\/catalog\/product\/75001.200.UL#\/75001.200.UL?CID=gsd_cap_sbu_r04_jp_cp1349_pjt5618_gsd00000_0so_blg_op_lgn_kt_s00_dne7_Social_LAB\" target=\"_blank\" rel=\"noopener noreferrer\">ExoSAP-IT\u2122 Express PCR Product Cleanup Reagent<\/a>\u3092\u9078\u629e\u3059\u308b\u3068\u3001PCR\u7523\u7269\u306e\u7cbe\u88fd\u304c5\u5206\u3067\u5b8c\u4e86\u3057\u307e\u3059\u3002<\/p>\n<h2>Fast\u30b5\u30a4\u30af\u30eb\u30b7\u30fc\u30b1\u30f3\u30b9\u53cd\u5fdc\u306e\u30dd\u30a4\u30f3\u30c8<\/h2>\n<p>Fast PCR\u304c\u53ef\u80fd\u306a\u30b5\u30fc\u30de\u30eb\u30b5\u30a4\u30af\u30e9\u30fc\u3068Applied Biosystems\u2122 BigDye\u2122 Terminator Cycle Sequencing\u8a66\u85ac\u3067\u6642\u9593\u77ed\u7e2e\u3092\u5b9f\u73fe\u3059\u308b\u305f\u3081\u306b\u958b\u767a\u3055\u308c\u305fFast\u30b7\u30fc\u30b1\u30f3\u30b9\u30d7\u30ed\u30c8\u30b3\u30eb\u3092\u4f7f\u7528\u3057\u307e\u3059\u3002<br \/>\n<img loading=\"lazy\" decoding=\"async\" class=\"aligncenter size-full wp-image-7351\" src=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2020\/06\/fig2.jpg\" alt=\"\" width=\"405\" height=\"116\" srcset=\"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2020\/06\/fig2.jpg 405w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2020\/06\/fig2-300x86.jpg 300w\" sizes=\"auto, (max-width: 405px) 100vw, 405px\" \/>\u5f93\u6765\u306e\u53cd\u5fdc\u6642\u9593\u3088\u308a\u7d041\u6642\u959320\u5206\u77ed\u7e2e\u3067\u304d\u307e\u3059\uff08\u4f7f\u7528\u3059\u308b\u30b5\u30fc\u30de\u30eb\u30b5\u30a4\u30af\u30e9\u30fc\u306e\u30e9\u30f3\u30d7\u30b9\u30d4\u30fc\u30c9\u306b\u3088\u3063\u3066\u3001\u77ed\u7e2e\u6642\u9593\u304c\u5909\u308f\u308a\u307e\u3059\uff09\u3002\u307e\u305f\u3001\u30b5\u30a4\u30af\u30eb\u30b7\u30fc\u30b1\u30f3\u30b9\u53cd\u5fdc\u5f8c\u306e\u7cbe\u88fd\u6cd5\u3068\u3057\u3066<a href=\"https:\/\/www.thermofisher.com\/order\/catalog\/product\/4376486#\/4376486?CID=gsd_cap_sbu_r04_jp_cp1349_pjt5618_gsd00000_0so_blg_op_lgn_kt_s00_dne7_Social_LAB\" target=\"_blank\" rel=\"noopener noreferrer\">Applied Biosystems\u2122 BigDye XTerminator\u2122 Purification Kit<\/a>\u3092\u9078\u629e\u3059\u308b\u3068\u3001\u30b5\u30f3\u30d7\u30eb\u7cbe\u88fd\u304c\u300c\u52a0\u3048\u3066\u300d\u300c\u6df7\u305c\u308b\u300d\u3060\u3051\u3067\u5b8c\u4e86\u3057\u307e\u3059\u3002<br \/>\n\u3053\u3061\u3089\u3082\u3054\u89a7\u304f\u3060\u3055\u3044<br \/>\n<iframe loading=\"lazy\" title=\"How to Purify Sequencing Reactions with the BigDye XTerminator Kit\" width=\"760\" height=\"428\" src=\"https:\/\/www.youtube.com\/embed\/_M62FSXMBf4?feature=oembed\" frameborder=\"0\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share\" referrerpolicy=\"strict-origin-when-cross-origin\" allowfullscreen><\/iframe><\/p>\n<h2>\u307e\u3068\u3081<\/h2>\n<p>\u30fbFast PCR\u304c\u53ef\u80fd\u306a\u30b5\u30fc\u30de\u30eb\u30b5\u30a4\u30af\u30e9\u30fc\u304b\u78ba\u8a8d\u3057\u307e\u3057\u3087\u3046<br \/>\n\u30fbPCR\u7523\u7269\u3092\u77ed\u6642\u9593\u3067\u5408\u6210\u3067\u304d\u308b\u9175\u7d20\u3092\u9078\u629e\u3057\u307e\u3057\u3087\u3046<br \/>\n\u30fbFast\u30b7\u30fc\u30b1\u30f3\u30b9\u30d7\u30ed\u30c8\u30b3\u30eb\u3067\u5927\u5e45\u306b\u6642\u9593\u77ed\u7e2e\u3057\u307e\u3057\u3087\u3046<\/p>\n<p>\u6642\u9593\u77ed\u7e2e\u3092\u304a\u8003\u3048\u306e\u65b9\u306f\u3001Fast PCR\u3092\u691c\u8a0e\u3057\u3066\u307f\u3066\u304f\u3060\u3055\u3044<\/p>\n<h2>\u3010\u7121\u6599\u516c\u958b\u4e2d\u3011\u30b5\u30f3\u30ac\u30fc\u30b7\u30fc\u30b1\u30f3\u30b9\u306e\u57fa\u790e<\/h2>\n<p>\u3053\u306e\u8cc7\u6599\u3067\u306f\u3001\u30ef\u30fc\u30af\u30d5\u30ed\u30fc\u304b\u3089\u30a2\u30d7\u30ea\u30b1\u30fc\u30b7\u30e7\u30f3\u307e\u3067\u30b5\u30f3\u30ac\u30fc\u30b7\u30fc\u30b1\u30f3\u30b9\u306e\u57fa\u672c\u3092\u5b66\u3079\u307e\u3059\u3002PDF\u30d5\u30a1\u30a4\u30eb\u306e\u30c0\u30a6\u30f3\u30ed\u30fc\u30c9\u3092\u3054\u5e0c\u671b\u306e\u65b9\u306f\u3001\u4e0b\u8a18\u30dc\u30bf\u30f3\u3088\u308a\u304a\u7533\u3057\u8fbc\u307f\u304f\u3060\u3055\u3044\u3002<\/p>\n<p><a class=\"btn btn-red\" href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/global\/forms\/sanger-sequencing-guide-download.html?CID=gsd_cap_sbu_r04_jp_cp1349_pjt5618_gsd00000_0so_blg_op_lgn_kt_s00_dne7_Social_LAB\" target=\"_blank\" rel=\"noopener noreferrer\">\u30c0\u30a6\u30f3\u30ed\u30fc\u30c9\u3059\u308b<\/a><\/p>\n<p>&nbsp;<\/p>\n<p>\u7814\u7a76\u7528\u306b\u306e\u307f\u4f7f\u7528\u3067\u304d\u307e\u3059\u3002\u8a3a\u65ad\u7528\u306b\u306f\u4f7f\u7528\u3044\u305f\u3060\u3051\u307e\u305b\u3093\u3002<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Fast PCR\u306f\u8fc5\u901f\u306b\u7d50\u679c\u3092\u51fa\u305b\u308b\u6a5f\u5668\u30fb\u8a66\u85ac\u3092\u7d44\u307f\u5408\u308f\u305b\u3066\u4f7f\u7528\u3059\u308b\u3053\u3068\u306b\u3088\u308a\u3001\u5b9f\u9a13\u6642\u9593\u3092\u5927\u5e45\u306b\u77ed\u7e2e\u3067\u304d\u308b\u6280\u8853\u3067\u3059\u3002\u3053\u306e\u6280\u8853\u306b\u3088\u308a\u3001\u300cPCR\u53cd\u5fdc\u300d\u3068\u300c\u30b5\u30a4\u30af\u30eb\u30b7\u30fc\u30b1\u30f3\u30b9\u53cd\u5fdc\u300d\u306e\u4e21\u65b9\u306e\u30e9\u30f3\u30bf\u30a4\u30e0\u3092\u5927\u5e45\u306b\u77ed\u7e2e\u3059\u308b\u3053\u3068\u304c\u3067\u304d\u307e<\/p>\n","protected":false},"author":975,"featured_media":10147,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_monsterinsights_skip_tracking":false,"_genesis_hide_title":false,"_genesis_hide_breadcrumbs":false,"_genesis_hide_singular_image":false,"_genesis_hide_footer_widgets":false,"_genesis_custom_body_class":"","_genesis_custom_post_class":"","_genesis_layout":"","_jetpack_newsletter_access":"","_jetpack_dont_email_post_to_subs":false,"_jetpack_newsletter_tier_id":0,"_jetpack_memberships_contains_paywalled_content":false,"_jetpack_feature_clip_id":0,"_jetpack_memberships_contains_paid_content":false,"footnotes":"","jetpack_post_was_ever_published":false},"categories":[156],"tags":[172],"division":[],"class_list":{"0":"post-7346","1":"post","2":"type-post","3":"status-publish","4":"format-standard","5":"has-post-thumbnail","7":"category-mol-bio","8":"tag-ce","9":"entry"},"_selected_authors":"","_selected_reviewers":"","acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v27.8 (Yoast SEO v27.8) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>\u5922\u306e\u6642\u9593\u77ed\u7e2e\uff01Fast\u30b5\u30a4\u30af\u30eb\u30b7\u30fc\u30b1\u30f3\u30b9\u3092\u3054\u5b58\u3058\u3067\u3059\u304b\uff1f - Learning at the Bench<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/fastpcr_ce_gsd_ts_1\/\" \/>\n<meta property=\"og:locale\" content=\"ja_JP\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"\u5922\u306e\u6642\u9593\u77ed\u7e2e\uff01Fast\u30b5\u30a4\u30af\u30eb\u30b7\u30fc\u30b1\u30f3\u30b9\u3092\u3054\u5b58\u3058\u3067\u3059\u304b\uff1f\" \/>\n<meta property=\"og:description\" content=\"Fast PCR\u306f\u8fc5\u901f\u306b\u7d50\u679c\u3092\u51fa\u305b\u308b\u6a5f\u5668\u30fb\u8a66\u85ac\u3092\u7d44\u307f\u5408\u308f\u305b\u3066\u4f7f\u7528\u3059\u308b\u3053\u3068\u306b\u3088\u308a\u3001\u5b9f\u9a13\u6642\u9593\u3092\u5927\u5e45\u306b\u77ed\u7e2e\u3067\u304d\u308b\u6280\u8853\u3067\u3059\u3002\u3053\u306e\u6280\u8853\u306b\u3088\u308a\u3001\u300cPCR\u53cd\u5fdc\u300d\u3068\u300c\u30b5\u30a4\u30af\u30eb\u30b7\u30fc\u30b1\u30f3\u30b9\u53cd\u5fdc\u300d\u306e\u4e21\u65b9\u306e\u30e9\u30f3\u30bf\u30a4\u30e0\u3092\u5927\u5e45\u306b\u77ed\u7e2e\u3059\u308b\u3053\u3068\u304c\u3067\u304d\u307e\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/fastpcr_ce_gsd_ts_1\/\" \/>\n<meta property=\"og:site_name\" content=\"Learning at the Bench\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/ThermoFisherJapan\" \/>\n<meta property=\"article:published_time\" content=\"2020-06-30T04:26:53+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2024-09-18T08:11:02+00:00\" \/>\n<meta property=\"og:image\" content=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2020\/06\/2021-10-13_12h26_43.png\" \/>\n\t<meta property=\"og:image:width\" content=\"709\" \/>\n\t<meta property=\"og:image:height\" content=\"271\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/png\" \/>\n<meta name=\"author\" content=\"LatB Staff\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:creator\" content=\"@ThermoFisherJP\" \/>\n<meta name=\"twitter:site\" content=\"@ThermoFisherJP\" \/>\n<meta name=\"twitter:label1\" content=\"\u57f7\u7b46\u8005\" \/>\n\t<meta name=\"twitter:data1\" content=\"LatB Staff\" \/>\n\t<meta name=\"twitter:label2\" content=\"\u63a8\u5b9a\u8aad\u307f\u53d6\u308a\u6642\u9593\" \/>\n\t<meta name=\"twitter:data2\" content=\"4\u5206\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/fastpcr_ce_gsd_ts_1\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/fastpcr_ce_gsd_ts_1\\\/\"},\"author\":{\"name\":\"LatB Staff\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#\\\/schema\\\/person\\\/bdbe319a2001f279ddce6ab8eaad1253\"},\"headline\":\"\u5922\u306e\u6642\u9593\u77ed\u7e2e\uff01Fast\u30b5\u30a4\u30af\u30eb\u30b7\u30fc\u30b1\u30f3\u30b9\u3092\u3054\u5b58\u3058\u3067\u3059\u304b\uff1f\",\"datePublished\":\"2020-06-30T04:26:53+00:00\",\"dateModified\":\"2024-09-18T08:11:02+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/fastpcr_ce_gsd_ts_1\\\/\"},\"wordCount\":67,\"commentCount\":0,\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/fastpcr_ce_gsd_ts_1\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2020\\\/06\\\/2021-10-13_12h26_43.png\",\"keywords\":[\"\u30ad\u30e3\u30d4\u30e9\u30ea\u30fc\u96fb\u6c17\u6cf3\u52d5\"],\"articleSection\":[\"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023\"],\"inLanguage\":\"ja\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/fastpcr_ce_gsd_ts_1\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/fastpcr_ce_gsd_ts_1\\\/\",\"url\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/fastpcr_ce_gsd_ts_1\\\/\",\"name\":\"\u5922\u306e\u6642\u9593\u77ed\u7e2e\uff01Fast\u30b5\u30a4\u30af\u30eb\u30b7\u30fc\u30b1\u30f3\u30b9\u3092\u3054\u5b58\u3058\u3067\u3059\u304b\uff1f - Learning at the Bench\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/fastpcr_ce_gsd_ts_1\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/fastpcr_ce_gsd_ts_1\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2020\\\/06\\\/2021-10-13_12h26_43.png\",\"datePublished\":\"2020-06-30T04:26:53+00:00\",\"dateModified\":\"2024-09-18T08:11:02+00:00\",\"author\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#\\\/schema\\\/person\\\/bdbe319a2001f279ddce6ab8eaad1253\"},\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/fastpcr_ce_gsd_ts_1\\\/#breadcrumb\"},\"inLanguage\":\"ja\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/fastpcr_ce_gsd_ts_1\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"ja\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/fastpcr_ce_gsd_ts_1\\\/#primaryimage\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2020\\\/06\\\/2021-10-13_12h26_43.png\",\"contentUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2020\\\/06\\\/2021-10-13_12h26_43.png\",\"width\":709,\"height\":271},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/fastpcr_ce_gsd_ts_1\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"\u5922\u306e\u6642\u9593\u77ed\u7e2e\uff01Fast\u30b5\u30a4\u30af\u30eb\u30b7\u30fc\u30b1\u30f3\u30b9\u3092\u3054\u5b58\u3058\u3067\u3059\u304b\uff1f\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#website\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/\",\"name\":\"Learning at the Bench\",\"description\":\"\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"ja\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#\\\/schema\\\/person\\\/bdbe319a2001f279ddce6ab8eaad1253\",\"name\":\"LatB Staff\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"ja\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g\",\"caption\":\"LatB Staff\"},\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/author\\\/lgbadmin\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"\u5922\u306e\u6642\u9593\u77ed\u7e2e\uff01Fast\u30b5\u30a4\u30af\u30eb\u30b7\u30fc\u30b1\u30f3\u30b9\u3092\u3054\u5b58\u3058\u3067\u3059\u304b\uff1f - Learning at the Bench","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/fastpcr_ce_gsd_ts_1\/","og_locale":"ja_JP","og_type":"article","og_title":"\u5922\u306e\u6642\u9593\u77ed\u7e2e\uff01Fast\u30b5\u30a4\u30af\u30eb\u30b7\u30fc\u30b1\u30f3\u30b9\u3092\u3054\u5b58\u3058\u3067\u3059\u304b\uff1f","og_description":"Fast PCR\u306f\u8fc5\u901f\u306b\u7d50\u679c\u3092\u51fa\u305b\u308b\u6a5f\u5668\u30fb\u8a66\u85ac\u3092\u7d44\u307f\u5408\u308f\u305b\u3066\u4f7f\u7528\u3059\u308b\u3053\u3068\u306b\u3088\u308a\u3001\u5b9f\u9a13\u6642\u9593\u3092\u5927\u5e45\u306b\u77ed\u7e2e\u3067\u304d\u308b\u6280\u8853\u3067\u3059\u3002\u3053\u306e\u6280\u8853\u306b\u3088\u308a\u3001\u300cPCR\u53cd\u5fdc\u300d\u3068\u300c\u30b5\u30a4\u30af\u30eb\u30b7\u30fc\u30b1\u30f3\u30b9\u53cd\u5fdc\u300d\u306e\u4e21\u65b9\u306e\u30e9\u30f3\u30bf\u30a4\u30e0\u3092\u5927\u5e45\u306b\u77ed\u7e2e\u3059\u308b\u3053\u3068\u304c\u3067\u304d\u307e","og_url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/fastpcr_ce_gsd_ts_1\/","og_site_name":"Learning at the Bench","article_publisher":"https:\/\/www.facebook.com\/ThermoFisherJapan","article_published_time":"2020-06-30T04:26:53+00:00","article_modified_time":"2024-09-18T08:11:02+00:00","og_image":[{"width":709,"height":271,"url":"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2020\/06\/2021-10-13_12h26_43.png","type":"image\/png"}],"author":"LatB Staff","twitter_card":"summary_large_image","twitter_creator":"@ThermoFisherJP","twitter_site":"@ThermoFisherJP","twitter_misc":{"\u57f7\u7b46\u8005":"LatB Staff","\u63a8\u5b9a\u8aad\u307f\u53d6\u308a\u6642\u9593":"4\u5206"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/fastpcr_ce_gsd_ts_1\/#article","isPartOf":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/fastpcr_ce_gsd_ts_1\/"},"author":{"name":"LatB Staff","@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#\/schema\/person\/bdbe319a2001f279ddce6ab8eaad1253"},"headline":"\u5922\u306e\u6642\u9593\u77ed\u7e2e\uff01Fast\u30b5\u30a4\u30af\u30eb\u30b7\u30fc\u30b1\u30f3\u30b9\u3092\u3054\u5b58\u3058\u3067\u3059\u304b\uff1f","datePublished":"2020-06-30T04:26:53+00:00","dateModified":"2024-09-18T08:11:02+00:00","mainEntityOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/fastpcr_ce_gsd_ts_1\/"},"wordCount":67,"commentCount":0,"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/fastpcr_ce_gsd_ts_1\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2020\/06\/2021-10-13_12h26_43.png","keywords":["\u30ad\u30e3\u30d4\u30e9\u30ea\u30fc\u96fb\u6c17\u6cf3\u52d5"],"articleSection":["\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023"],"inLanguage":"ja","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/fastpcr_ce_gsd_ts_1\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/fastpcr_ce_gsd_ts_1\/","url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/fastpcr_ce_gsd_ts_1\/","name":"\u5922\u306e\u6642\u9593\u77ed\u7e2e\uff01Fast\u30b5\u30a4\u30af\u30eb\u30b7\u30fc\u30b1\u30f3\u30b9\u3092\u3054\u5b58\u3058\u3067\u3059\u304b\uff1f - Learning at the Bench","isPartOf":{"@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/fastpcr_ce_gsd_ts_1\/#primaryimage"},"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/fastpcr_ce_gsd_ts_1\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2020\/06\/2021-10-13_12h26_43.png","datePublished":"2020-06-30T04:26:53+00:00","dateModified":"2024-09-18T08:11:02+00:00","author":{"@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#\/schema\/person\/bdbe319a2001f279ddce6ab8eaad1253"},"breadcrumb":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/fastpcr_ce_gsd_ts_1\/#breadcrumb"},"inLanguage":"ja","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/fastpcr_ce_gsd_ts_1\/"]}]},{"@type":"ImageObject","inLanguage":"ja","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/fastpcr_ce_gsd_ts_1\/#primaryimage","url":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2020\/06\/2021-10-13_12h26_43.png","contentUrl":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2020\/06\/2021-10-13_12h26_43.png","width":709,"height":271},{"@type":"BreadcrumbList","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/fastpcr_ce_gsd_ts_1\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/"},{"@type":"ListItem","position":2,"name":"\u5922\u306e\u6642\u9593\u77ed\u7e2e\uff01Fast\u30b5\u30a4\u30af\u30eb\u30b7\u30fc\u30b1\u30f3\u30b9\u3092\u3054\u5b58\u3058\u3067\u3059\u304b\uff1f"}]},{"@type":"WebSite","@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#website","url":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/","name":"Learning at the Bench","description":"","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"ja"},{"@type":"Person","@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#\/schema\/person\/bdbe319a2001f279ddce6ab8eaad1253","name":"LatB Staff","image":{"@type":"ImageObject","inLanguage":"ja","@id":"https:\/\/secure.gravatar.com\/avatar\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g","caption":"LatB Staff"},"url":"https:\/\/admin.acceleratingscience.com\/author\/lgbadmin\/"}]}},"taxonomy_info":{"category":[{"value":156,"label":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023"}],"post_tag":[{"value":172,"label":"\u30ad\u30e3\u30d4\u30e9\u30ea\u30fc\u96fb\u6c17\u6cf3\u52d5"}]},"featured_image_src_large":["https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2020\/06\/2021-10-13_12h26_43.png",709,271,false],"author_info":{"display_name":"LatB Staff","author_link":"https:\/\/admin.acceleratingscience.com\/author\/lgbadmin\/"},"comment_info":0,"category_info":[{"term_id":156,"name":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","slug":"mol-bio","term_group":0,"term_taxonomy_id":156,"taxonomy":"category","description":"","parent":0,"count":538,"filter":"raw","meta":[],"cat_ID":156,"category_count":538,"category_description":"","cat_name":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","category_nicename":"mol-bio","category_parent":0}],"tag_info":[{"term_id":172,"name":"\u30ad\u30e3\u30d4\u30e9\u30ea\u30fc\u96fb\u6c17\u6cf3\u52d5","slug":"ce","term_group":0,"term_taxonomy_id":172,"taxonomy":"post_tag","description":"","parent":0,"count":34,"filter":"raw","meta":[]}],"jetpack-related-posts":[{"id":23370,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/pcr-dna-gsd-ts-tr-25061\/","url_meta":{"origin":7346,"position":0},"title":"\u3010\u3084\u3063\u3066\u307f\u305f\u3011PCR\u5f8c\u306e\u4fdd\u5b58\u6e29\u5ea6\u306f4\u2103\u4e00\u629e\u3067\u3059\u304b\uff1f\u4ed6\u306e\u6e29\u5ea6\u3082\u8a66\u3057\u3066\u307f\u305f","author":"LatB Staff","date":"2025\u5e7410\u670816\u65e5","format":false,"excerpt":"PCR\uff08\u30dd\u30ea\u30e1\u30e9\u30fc\u30bc\u9023\u9396\u53cd\u5fdc\uff09\u306f\u3001\u5206\u5b50\u751f\u7269\u5b66\u306e\u5b9f\u9a13\u306e\u6839\u5e79\u3092\u306a\u3059\u975e\u5e38\u306b\u91cd\u8981\u306a\u6280\u8853\u3067\u3059\u3002PCR\u3092\u884c\u3063\u305f\u5f8c\u2026","rel":"","context":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","block_context":{"text":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/mol-bio\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/10\/pcr-dna-gsd-ts-tr-25061_eyecatch.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/10\/pcr-dna-gsd-ts-tr-25061_eyecatch.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/10\/pcr-dna-gsd-ts-tr-25061_eyecatch.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/10\/pcr-dna-gsd-ts-tr-25061_eyecatch.jpg?resize=700%2C400&ssl=1 2x"},"classes":[]},{"id":25247,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/exosome-gene-expression-ts-r-25018\/","url_meta":{"origin":7346,"position":1},"title":"\u3010\u7b2c4\u56de\u3011&#8221;RNA cargo&#8221;\u306e\u7cbe\u88fd\u3068\u5b9a\u91cf\u89e3\u6790\uff5emiRNA\u306e\u5b9a\u91cf\u89e3\u6790\uff5e","author":"LatB Staff","date":"2026\u5e745\u670829\u65e5","format":false,"excerpt":"\u524d\u56de\uff08\u3010\u7b2c3\u56de\u3011\u201cRNA cargo\u201d\u306e\u7cbe\u88fd\u3068\u5b9a\u91cf\u89e3\u6790\uff09\u3067\u306f\u3001\u30a8\u30af\u30bd\u30bd\u30fc\u30e0 \uff08\u30a8\u30ad\u30bd\u30bd\u30fc\u30e0\uff09 \u304b\u3089\u306e\u2026","rel":"","context":"\u5206\u6790\u30fb\u6e2c\u5b9a\u95a2\u9023","block_context":{"text":"\u5206\u6790\u30fb\u6e2c\u5b9a\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/analysis\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25018_eyecatch-1.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25018_eyecatch-1.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25018_eyecatch-1.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25018_eyecatch-1.jpg?resize=700%2C400&ssl=1 2x"},"classes":[]},{"id":25325,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/exosome-gene-expression-ts-r-25019\/","url_meta":{"origin":7346,"position":2},"title":"\u3010\u7b2c5\u56de\u3011 &#8220;RNA cargo&#8221;\u306e\u7cbe\u88fd\u3068\u5b9a\u91cf\u89e3\u6790\u300d\uff5emRNA\u306e\u5b9a\u91cf\u89e3\u6790\uff5e","author":"LatB Staff","date":"2026\u5e746\u670811\u65e5","format":false,"excerpt":"\u4eca\u56de\u306f\u3001\u30a8\u30af\u30bd\u30bd\u30fc\u30e0\uff08\u30a8\u30ad\u30bd\u30bd\u30fc\u30e0\uff09\u4e2d\u306emRNA\u306e\u5b9a\u91cf\u89e3\u6790\u306b\u3064\u3044\u3066\u8aac\u660e\u3057\u307e\u3059\u3002\u7b2c3\u56de\u3067\u30a8\u30af\u30bd\u30bd\u30fc\u30e0\u304b\u2026","rel":"","context":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","block_context":{"text":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/mol-bio\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25018_eyecatch-1.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25018_eyecatch-1.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25018_eyecatch-1.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25018_eyecatch-1.jpg?resize=700%2C400&ssl=1 2x"},"classes":[]},{"id":23665,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/pcr-dna-gsd-ts-tr-25064\/","url_meta":{"origin":7346,"position":3},"title":"\u3010\u3084\u3063\u3066\u307f\u305f\u3011PCR\u306e\u30a2\u30cb\u30fc\u30ea\u30f3\u30b0\u6e29\u5ea6\u3092\u601d\u3044\u5207\u308a\u632f\u3063\u3066\u307f\u305f","author":"LatB Staff","date":"2025\u5e7410\u670828\u65e5","format":false,"excerpt":"\u65b0\u305f\u306aPCR\u691c\u51fa\u7cfb\u3092\u69cb\u7bc9\u3059\u308b\u5834\u5408\u3001\u4f55\u3088\u308a\u3082\u30d7\u30e9\u30a4\u30de\u30fc\u306e\u914d\u5217\u304c\u91cd\u8981\u3068\u3044\u3046\u3053\u3068\u306f\u591a\u304f\u306e\u65b9\u304c\u8a8d\u8b58\u3057\u3066\u3044\u308b\u306e\u2026","rel":"","context":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","block_context":{"text":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/mol-bio\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/10\/pcr-dna-gsd-ts-tr-25064_eyecatch-scaled.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/10\/pcr-dna-gsd-ts-tr-25064_eyecatch-scaled.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/10\/pcr-dna-gsd-ts-tr-25064_eyecatch-scaled.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/10\/pcr-dna-gsd-ts-tr-25064_eyecatch-scaled.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/10\/pcr-dna-gsd-ts-tr-25064_eyecatch-scaled.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/10\/pcr-dna-gsd-ts-tr-25064_eyecatch-scaled.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":24545,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/digital-pcr-gene-expression-gsd-ts-sd-25082\/","url_meta":{"origin":7346,"position":4},"title":"\u3010Absolute Q\u30c7\u30b8\u30bf\u30ebPCR\u30b7\u30b9\u30c6\u30e0\u306e\u6d3b\u7528\u4f8b\u3011\u30df\u30c8\u30b3\u30f3\u30c9\u30ea\u30a2DNA\u306e\u5b9a\u91cf","author":"LatB Staff","date":"2026\u5e741\u670816\u65e5","format":false,"excerpt":"Applied Biosystems\u2122 QuantStudio\u2122 Absolute Q\u2122 \u30c7\u30b8\u30bf\u30ebP\u2026","rel":"","context":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","block_context":{"text":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/mol-bio\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/12\/digital-pcr-gene-expression-gsd-ts-sd-25082_eyecatch.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/12\/digital-pcr-gene-expression-gsd-ts-sd-25082_eyecatch.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/12\/digital-pcr-gene-expression-gsd-ts-sd-25082_eyecatch.jpg?resize=525%2C300&ssl=1 1.5x"},"classes":[]},{"id":25565,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/exosome-antibody-ts-r-25068_\/","url_meta":{"origin":7346,"position":5},"title":"\u3010\u7b2c8\u56de\u3011\u30a8\u30af\u30bd\u30bd\u30fc\u30e0\u30b5\u30d6\u30bf\u30a4\u30d7\u306e\u5206\u753b\u6cd5 \uff1a \u30a6\u30a7\u30b9\u30bf\u30f3\u30d6\u30ed\u30c3\u30c8\uff0fqRT-PCR\uff0f\u30b7\u30fc\u30b1\u30f3\u30b9\u89e3\u6790\u306b\u9069\u3057\u305f\u5206\u753b\u65b9\u6cd5","author":"LatB Staff","date":"2026\u5e749\u670829\u65e5","format":false,"excerpt":"\u672c\u7a3f\u3067\u306f\u3001\u30a8\u30af\u30bd\u30bd\u30fc\u30e0\u819c\u4e0a\u306e\u7279\u5b9a\u306e\u30bf\u30f3\u30d1\u30af\u8cea\u3092\u6a19\u7684\u3068\u3057\u305f\u514d\u75ab\u5438\u7740\u6cd5\u306b\u57fa\u3065\u304f\u5206\u753b\u624b\u6cd5\u3092\u7d39\u4ecb\u3057\u307e\u3059\u3002\u30a8\u30af\u2026","rel":"","context":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","block_context":{"text":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/mol-bio\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25019_eyecatch.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25019_eyecatch.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25019_eyecatch.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25019_eyecatch.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25019_eyecatch.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25019_eyecatch.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]}],"jetpack_sharing_enabled":true,"amp_enabled":true,"jetpack_featured_media_url":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2020\/06\/2021-10-13_12h26_43.png","_links":{"self":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/posts\/7346","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/users\/975"}],"replies":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/comments?post=7346"}],"version-history":[{"count":0,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/posts\/7346\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/media\/10147"}],"wp:attachment":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/media?parent=7346"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/categories?post=7346"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/tags?post=7346"},{"taxonomy":"division","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/division?post=7346"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}