{"id":768,"date":"2017-04-06T00:00:00","date_gmt":"2017-04-06T00:00:00","guid":{"rendered":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/qpcr-basic43\/"},"modified":"2025-04-16T15:22:17","modified_gmt":"2025-04-16T06:22:17","slug":"qpcr-basic43","status":"publish","type":"post","link":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/qpcr-basic43\/","title":{"rendered":"\u6709\u6a5f\u6eb6\u5a92\uff1f\u305d\u308c\u3068\u3082\u30b7\u30ea\u30ab\u30d9\u30fc\u30b9\uff1f \u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u306b\u304a\u3051\u308b\u6838\u9178\u306e\u7cbe\u88fd\u304a\u3088\u3073\u5b9a\u91cf\u65b9\u6cd5"},"content":{"rendered":"<h2>\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u306b\u304a\u3051\u308b\u6838\u9178\u7cbe\u88fd\u6cd5<\/h2>\n<p>\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u306b\u7528\u3044\u308b\u6838\u9178\u306e\u7cbe\u88fd\u3092\u884c\u3046\u524d\u306b\u3001\u30b5\u30f3\u30d7\u30eb\u306e\u7a2e\u985e\uff08\u7d30\u80de\u307e\u305f\u306f\u7d44\u7e54\uff09\u304a\u3088\u3073\u9069\u5207\u306a\u7cbe\u88fd\u65b9\u6cd5\u306e\u9078\u629e\u306b\u3064\u3044\u3066\u8003\u5bdf\u3059\u308b\u3053\u3068\u304c\u5fc5\u8981\u3067\u3059\u3002DNA\u304a\u3088\u3073RNA\u5206\u96e2\u6cd5\u306b\u3088\u308a\u3001\u7c21\u4fbf\u6027\u3084\u3001\u6709\u6a5f\u6eb6\u5a92\u306e\u5fc5\u8981\u306e\u6709\u7121\u3001\u304a\u3088\u3073\u56de\u53ce\u3057\u305f\u6838\u9178\u306e\u7d14\u5ea6\uff08DNA\uff08RNA\u7cbe\u88fd\u306e\u5834\u5408\uff09\u3001\u30bf\u30f3\u30d1\u30af\u8cea\u3001\u6709\u6a5f\u6eb6\u5a92\u306e\u6b8b\u5b58\uff09\u304c\u7570\u306a\u308a\u307e\u3059\u3002<\/p>\n<p>\u4eca\u56de\u306f\u3001<strong>\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u306b\u304a\u3051\u308b\u6838\u9178\u306e\u7cbe\u88fd\u304a\u3088\u3073\u5b9a\u91cf\u65b9\u6cd5<\/strong>\u306b\u3064\u3044\u3066\u3001\u4e3b\u3068\u3057\u3066RNA\u5206\u96e2\u306b\u3064\u3044\u3066\u3054\u7d39\u4ecb\u3057\u307e\u3059\u304c\u3001\u30ac\u30a4\u30c9\u30e9\u30a4\u30f3\u306e\u307b\u3068\u3093\u3069\u306fDNA\u306e\u5206\u96e2\u306b\u3082\u5f53\u3066\u306f\u307e\u308a\u307e\u3059\u3002<\/p>\n<h2>\u6709\u6a5f\u6eb6\u5a92\u3092\u7528\u3044\u305f\u7cbe\u88fd\u6cd5<\/h2>\n<p><strong>1-Step \u306e\u8a66\u85ac\u30d9\u30fc\u30b9\u306e\u6709\u6a5f\u62bd\u51fa\u6cd5\u306f\u3001RNA\u3092\u69d8\u3005\u306a\u7a2e\u985e\u306e\u7d30\u80de\u304a\u3088\u3073\u7d44\u7e54\u304b\u3089\u7cbe\u88fd\u3059\u308b\u306e\u306b\u975e\u5e38\u306b\u52b9\u679c\u7684\u306a\u65b9\u6cd5\u3067\u3059\u3002<\/strong>\u591a\u304f\u306e\u30d7\u30ed\u30c8\u30b3\u30eb\u3067\u306f\u3001\u6838\u9178\u3092RNase\u306e\u4f5c\u7528\u304b\u3089\u4fdd\u8b77\u3057\u3001\u6838\u9178\u306e\u5b8c\u5168\u6027\u3092\u7dad\u6301\u3057\u306a\u304c\u3089\u7d30\u80de\u3092\u7834\u58ca\u3057\u3066\u7d30\u80de\u6210\u5206\u3092\u6eb6\u89e3\u3059\u308b\u305f\u3081\u306b\u3001\u30d5\u30a7\u30ce\u30fc\u30eb\u3068\u30b0\u30a2\u30cb\u30b8\u30f3\u30a4\u30bd\u30c1\u30aa\u30b7\u30a2\u30cd\u30fc\u30c8\u306e\u6df7\u5408\u7269\u3092\u4f7f\u7528\u3057\u307e\u3059\u3002\u901a\u5e38\u3001\u305d\u3053\u306b\u30af\u30ed\u30ed\u30db\u30eb\u30e0\u3092\u6dfb\u52a0\u3057\u3001\u9060\u5fc3\u5206\u96e2\u306b\u3088\u3063\u3066\u6df7\u5408\u7269\u3092\u6c34\u76f8\u3068\u6709\u6a5f\u76f8\u306b\u5206\u96e2\u3057\u307e\u3059\u3002\u30b0\u30a2\u30cb\u30b8\u30f3\u30a4\u30bd\u30c1\u30aa\u30b7\u30a2\u30cd\u30fc\u30c8\u306e\u5b58\u5728\u4e0b\u3067\u306fRNA\u306f\u6c34\u76f8\u306b\u5b58\u5728\u3057\u3001DNA\u304a\u3088\u3073\u30bf\u30f3\u30d1\u30af\u8cea\u306f\u6709\u6a5f\u76f8\u304a\u3088\u3073\u4e2d\u9593\u76f8\u306b\u79fb\u52d5\u3057\u307e\u3059\u3002\u305d\u306e\u5f8cRNA\u3092\u30a4\u30bd\u30d7\u30ed\u30d1\u30ce\u30fc\u30eb\u6c88\u6bbf\u306b\u3088\u308a\u6c34\u76f8\u304b\u3089\u56de\u53ce\u3057\u307e\u3059\u3002<\/p>\n<p><strong>\u3053\u306e\u65b9\u6cd5\u306f\u6bd4\u8f03\u7684\u8fc5\u901f\u3067\u3042\u308a\u3001\u9ad8\u53ce\u91cf\u3067RNA\u3092\u5f97\u308b\u3053\u3068\u304c\u53ef\u80fd\u3067\u3059\u304c\u3001\u6bd2\u6027\u306e\u3042\u308b\u5316\u5b66\u85ac\u54c1\u3092\u4f7f\u7528\u3059\u308b\u3053\u3068\u304c\u5fc5\u8981\u3067\u3001\u4ed6\u306e\u65b9\u6cd5\u3068\u6bd4\u8f03\u3057\u3066\u3088\u308a\u9ad8\u304fDNA\u304c\u6b8b\u5b58\u3059\u308b\u53ef\u80fd\u6027\u304c\u3042\u308a\u307e\u3059\u3002<\/strong>\u6b8b\u7559\u3059\u308b\u30b0\u30a2\u30cb\u30b8\u30f3\u3001\u30d5\u30a7\u30ce\u30fc\u30eb\u307e\u305f\u306f\u30a2\u30eb\u30b3\u30fc\u30eb\u304ccDNA\u5408\u6210\u52b9\u7387\u3092\u8457\u3057\u304f\u4f4e\u4e0b\u3055\u305b\u308b\u53ef\u80fd\u6027\u3082\u3042\u308a\u307e\u3059\u3002<\/p>\n<h2>\u30b7\u30ea\u30ab\u30d3\u30fc\u30ba\u307e\u305f\u306f\u30d5\u30a3\u30eb\u30bf\u30fc\u30d9\u30fc\u30b9\u3092\u7528\u3044\u305f\u7cbe\u88fd\u6cd5<\/h2>\n<p><strong>\u307b\u3068\u3093\u3069\u306e\u30b7\u30ea\u30ab\u30d3\u30fc\u30ba\u307e\u305f\u306f\u30d5\u30a3\u30eb\u30bf\u30fc\u30d9\u30fc\u30b9\u306e\u65b9\u6cd5\u3067\u306f\u3001RNA\u3092\u5185\u5728\u6027\u306eRNase\u306e\u4f5c\u7528\u304b\u3089\u4fdd\u8b77\u3059\u308b\u30ab\u30aa\u30c8\u30ed\u30d4\u30c3\u30af\u5869\u3067\u3042\u308b\u30b0\u30a2\u30cb\u30b8\u30f3\u30a4\u30bd\u30c1\u30aa\u30b7\u30a2\u30cd\u30fc\u30c8\u306e\u5b58\u5728\u4e0b\u3067\u8a66\u6599\u306e\u6eb6\u89e3\u304a\u3088\u3073\u5747\u8cea\u5316\u3092\u884c\u3044\u307e\u3059<\/strong>\uff08 <a href=\"https:\/\/www.ncbi.nlm.nih.gov\/pubmed\/518835\" target=\"_blank\" rel=\"noopener noreferrer\">Biochemistry 18:5294 \uff081979\uff09<\/a>\uff09\u3002\u5747\u8cea\u5316\u306e\u5f8c\u3001\u8a66\u6599\u306b\u30a8\u30bf\u30ce\u30fc\u30eb\u3092\u6dfb\u52a0\u3057\u3066RNA\u3092\u30b7\u30ea\u30ab\u30d9\u30fc\u30b9\u306e\u30d3\u30fc\u30ba\u307e\u305f\u306f\u30d5\u30a3\u30eb\u30bf\u30fc\u306b\u7d50\u5408\u3055\u305b\u3001\u4e0d\u7d14\u7269\u3092\u6d17\u6d44\u306b\u3088\u3063\u3066\u52b9\u7387\u3088\u304f\u9664\u53bb\u3057\u307e\u3059\uff08<a href=\"https:\/\/www.ncbi.nlm.nih.gov\/pubmed\/284385\" target=\"_blank\" rel=\"noopener noreferrer\">Proc Natl Acad Sci USA 76:615\uff081979\uff09<\/a>\uff09\u3002\u7cbe\u88fd\u3057\u305fTotal RNA\u306f\u6c34\u3067\u6eb6\u51fa\u3057\u307e\u3059\u3002<\/p>\n<p><strong>\u3053\u306e\u65b9\u6cd5\u306f\u6709\u6a5f\u6eb6\u5a92\u62bd\u51fa\u6cd5\u3088\u308a\u3082\u3055\u3089\u306b\u8fc5\u901f\u3067\u3001\u30d5\u30a7\u30ce\u30fc\u30eb\u3092\u5fc5\u8981\u3068\u3057\u307e\u305b\u3093\u3002<\/strong>RNA\u306e\u53ce\u91cf\u306f\u6eb6\u5a92\u62bd\u51fa\u307b\u3069\u9ad8\u304f\u3042\u308a\u307e\u305b\u3093\u304c\u3001\u30bf\u30f3\u30d1\u30af\u8cea\u3001\u8102\u8cea\u3001\u591a\u7cd6\u985e\u3001DNA\u304a\u3088\u3073\u7cbe\u88fd\u8a66\u85ac\u306b\u95a2\u3059\u308b\u7d14\u5ea6\u306f\u901a\u5e38\u6709\u6a5f\u6eb6\u5a92\u62bd\u51fa\u3088\u308a\u3082\u826f\u597d\u3067\u3059\u3002<strong>\u6d17\u6d44\u304c\u4e0d\u5b8c\u5168\u3060\u3068\u30b0\u30a2\u30cb\u30b8\u30f3\u304a\u3088\u3073\u30a8\u30bf\u30ce\u30fc\u30eb\u304c\u6b8b\u5b58\u3057\u3001cDNA\u5408\u6210\u52b9\u7387\u306b\u3068\u3082\u306b\u60aa\u5f71\u97ff\u3092\u4e0e\u3048\u308b\u53ef\u80fd\u6027\u304c\u3042\u308a\u307e\u3059\u3002<\/strong><\/p>\n<h2>RNA\u306e\u54c1\u8cea\u306e\u8a55\u4fa1<\/h2>\n<p><strong>RNA\u306e\u54c1\u8cea\u3068\u91cf\u306e\u8a55\u4fa1\u306b\u304a\u3044\u3066\u306f\u3001\u914d\u616e\u3059\u3079\u304d\u91cd\u8981\u70b9\u304c\u3044\u304f\u3064\u304b\u3042\u308a\u307e\u3059\u3002<\/strong>A260\/A280 \u6bd4\u304c1.8\u304b\u30892.0 \u306e\u9593\u3067\u3042\u308b\u3053\u3068\u3092\u78ba\u8a8d\u3057\u3066\u304f\u3060\u3055\u3044\u3002\u6bd4\u304c1.8 \u4ee5\u4e0b\u3067\u3042\u308b\u5834\u5408\u306b\u306f\u30bf\u30f3\u30d1\u30af\u8cea\u306e\u6c5a\u67d3\u304c\u793a\u5506\u3055\u308c\u3001\u53cd\u5fdc\u52b9\u7387\u3092\u4f4e\u4e0b\u3055\u305b\u308b\u53ef\u80fd\u6027\u304c\u3042\u308a\u307e\u3059\u3002A260\/A230 \u6bd4\u306f\u3001\u30ab\u30aa\u30c8\u30ed\u30d4\u30c3\u30af\u5869\u3067\u3042\u308b\u30b0\u30a2\u30cb\u30b8\u30f3\u30a4\u30bd\u30c1\u30aa\u30b7\u30a2\u30ca\u30fc\u30c8\u304a\u3088\u3073\u30d5\u30a7\u30ce\u30fc\u30eb\u306a\u3069\u3001\u9175\u7d20\u53cd\u5fdc\u3092\u963b\u5bb3\u3059\u308b\u3001\u30d5\u30a7\u30ce\u30fc\u30eb\u74b0\u3092\u6709\u3059\u308b\u6210\u5206\u306e\u6b8b\u5b58\u306e\u8a55\u4fa1\u306b\u6709\u7528\u3067\u3059\u3002RNA\u306e\u5206\u89e3\u5ea6\u3092\u3001\u5909\u6027\u30b2\u30eb\u4e0a\u307e\u305f\u306fAgilent Bioanalyzer\u306a\u3069\u306e\u88c5\u7f6e\u4e0a\u3067\u8a55\u4fa1\u3057\u3066\u304f\u3060\u3055\u3044\uff08\u56f3\uff09\u3002<\/p>\n<div id=\"attachment_2034\" style=\"width: 752px\" class=\"wp-caption aligncenter\"><a href=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/qpcr-basic43-fig.png\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-2034\" class=\"size-full wp-image-2034\" src=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/qpcr-basic43-fig.png\" alt=\"qpcr-basic43-fig\" width=\"742\" height=\"472\" \/><\/a><p id=\"caption-attachment-2034\" class=\"wp-caption-text\">\u56f3 RNA\u306e\u5206\u89e3\u5ea6\u3092\u793a\u3059\u3001Agilent Bioanalyzer\u30c8\u30ec\u30fc\u30b9\u304a\u3088\u3073\u30b2\u30eb\u30a4\u30e1\u30fc\u30b8\u30022\u3064\u306e\u86cd\u5149\u30d4\u30fc\u30af\u306f18S\u304a\u3088\u307328S\u306erRNA\u30d0\u30f3\u30c9\u306b\u76f8\u5f53\u3057\u307e\u3059\u3002\u5206\u89e3\u3057\u3066\u3044\u306a\u3044\u54fa\u4e73\u985e\u306etotal RNA \u306f\u300118S \u304a\u3088\u307328S \u306erRNA\u3092\u8868\u30592 \u672c\u306e\u30d0\u30f3\u30c9\u307e\u305f\u306f\u30d4\u30fc\u30af\u3092\u793a\u3057\u307e\u3059\u3002\u4e00\u822c\u7684\u306b\u300128S rRNA \u306e\u8f1d\u5ea6\u306f18S rRNA \u306e2 \u500d\u3067\u3059\uff08\u3042\u308b\u3044\u306fAgilent Bioanalyzer\u30c8\u30ec\u30fc\u30b9\u306b\u304a\u3051\u308b\u30d4\u30fc\u30af\u4e0b\u9762\u7a4d\u304c2\u500d\u3067\u3059\uff09\u3002<\/p><\/div>\n<p>Agilent Bioanalyzer\u3067\u306f\u3001RNA\u306e\u54c1\u8cea\u6c7a\u5b9a\u3092\u3055\u3089\u306b\u9032\u5316\u3055\u305b\u3066\u3001RIN\uff08RNA integrity number\uff09\u5024\u3092\u7b97\u51fa\u3057\u307e\u3059\u3002RIN\u5024\u306f\u3001\u5206\u89e3\u7523\u7269\u3082\u542b\u3081\u305f\u5168\u4f53\u306e\u30c8\u30ec\u30fc\u30b9\u304b\u3089\u7b97\u51fa\u3055\u308c\u3001\u901a\u5e38rRNA\u30d4\u30fc\u30af\u306e\u307f\u3092\u8a55\u4fa1\u3059\u308b\u3088\u308a\u3082\u512a\u308c\u3066\u3044\u307e\u3059\u3002<\/p>\n<p>\u7570\u306a\u308b\u7d44\u7e54\u7531\u6765\u306eRNA\u306b\u95a2\u3057\u3066RIN\u5024\u3092\u6bd4\u8f03\u3059\u308b\u3053\u3068\u306b\u3088\u308a\u3001\u54c1\u8cea\u306e\u6a19\u6e96\u5316\u304a\u3088\u3073\u4e00\u8cab\u6027\u306e\u7dad\u6301\u304c\u53ef\u80fd\u3067\u3059\u3002<\/p>\n<h2>\u5b9a\u91cf\u306e\u7cbe\u5ea6<\/h2>\n<p>RNA\u306e\u5b9a\u91cf\u306e\u305f\u3081\u306b\u306f\u3001\u3088\u308a\u9ad8\u3044\u611f\u5ea6\u3001\u7cbe\u5ea6\u304a\u3088\u3073\u9ad8\u30b9\u30eb\u30fc\u30d7\u30c3\u30c8\u3092\u5b9f\u73fe\u3059\u308b\u3088\u3046\u306b\u30c7\u30b6\u30a4\u30f3\u3055\u308c\u305f\u3001<a href=\"https:\/\/www.thermofisher.com\/order\/catalog\/product\/R11491?CID=gsd_pcr_sbu_r04_jp_cp0000_pjt0000_gsd00000_0so_blg_op_awa_oc_s00_qpcr49_Social_LAB\" target=\"_blank\" rel=\"noopener noreferrer\">Invitrogen\u2122 RiboGreen\u2122 \u8272\u7d20<\/a>\u304a\u3088\u3073<a href=\"https:\/\/www.thermofisher.com\/order\/catalog\/product\/P7581?CID=gsd_pcr_sbu_r04_jp_cp0000_pjt0000_gsd00000_0so_blg_op_awa_oc_s00_qpcr49_Social_LAB\" target=\"_blank\" rel=\"noopener noreferrer\">Invitrogen\u2122 PicoGreen\u2122 \u8272\u7d20<\/a>\u306a\u3069\u306e<strong>\u86cd\u5149\u8272\u7d20\u3092\u7528\u3044\u308b\u65b9\u6cd5\u304c\u3001UV\u5438\u53ce\u6cd5\u3088\u308a\u3082\u512a\u308c\u3066\u3044\u307e\u3059\u3002<\/strong>UV\u5438\u53ce\u6e2c\u5b9a\u6cd5\u3067\u306f\u6838\u9178\u3068\u904a\u96e2\u306e\u30cc\u30af\u30ec\u30aa\u30c1\u30c9\u3092\u8b58\u5225\u3059\u308b\u3053\u3068\u304c\u4e0d\u53ef\u80fd\u3067\u3059\u3002\u5b9f\u969b\u3001\u904a\u96e2\u306e\u30cc\u30af\u30ec\u30aa\u30c1\u30c9\u306f260nm\u306b\u304a\u3044\u3066\u6838\u9178\u3088\u308a\u3082\u5438\u53ce\u304c\u9ad8\u304f\u306a\u308a\u307e\u3059\u3002\u540c\u69d8\u306b\u3001UV\u5438\u53ce\u6e2c\u5b9a\u6cd5\u3067\u306f\u540c\u4e00\u8a66\u6599\u306b\u304a\u3044\u3066RNA\u3068DNA\u3092\u8b58\u5225\u3067\u304d\u307e\u305b\u3093\u3002\u3055\u3089\u306b\u7cbe\u88fd\u3057\u305f\u6838\u9178\u306b\u542b\u307e\u308c\u308b\u3053\u3068\u306e\u591a\u3044\u593e\u96d1\u7269\u306fUV\u5438\u53ce\u3092\u793a\u3057\u307e\u3059\u3002\u6700\u5f8c\u306b\u3001UV\u5438\u5149\u5149\u5ea6\u8a08\u306f\u6e2c\u5b9a\u306e\u305f\u3081\u306b\u304b\u306a\u308a\u306e\u91cf\u306e\u8a66\u6599\u3092\u6d88\u8cbb\u3057\u307e\u3059\u3002\u86cd\u5149\u8272\u7d20\u306b\u95a2\u3057\u3066\u306f\u5e45\u5e83\u3044\u7a2e\u985e\u306e\u8272\u7d20\u304c\u5165\u624b\u53ef\u80fd\u3067\u3059\u306e\u3067\u3001\u6838\u9178\u3092\u904a\u96e2\u306e\u30cc\u30af\u30ec\u30aa\u30c1\u30c9\u304b\u3089\u8b58\u5225\u3059\u308b\u3053\u3068\u304c\u53ef\u80fd\u306a\u8272\u7d20\u3001\u540c\u4e00\u8a66\u6599\u306b\u304a\u3044\u3066DNA\u3092RNA\u304b\u3089\u8b58\u5225\u3059\u308b\u3053\u3068\u304c\u53ef\u80fd\u306a\u8272\u7d20\u304a\u3088\u3073\u4e00\u822c\u7684\u306a\u593e\u96d1\u7269\u306b\u611f\u53d7\u6027\u306e\u306a\u3044\u8272\u7d20\u306a\u3069\u3001\u524d\u8ff0\u306e\u3059\u3079\u3066\u306e\u6b20\u70b9\u3092\u514b\u670d\u3059\u308b\u3053\u3068\u306e\u3067\u304d\u308b\u8a66\u85ac\u3092\u9078\u629e\u3059\u308b\u3053\u3068\u304c\u53ef\u80fd\u3067\u3059\u3002<a href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/industrial\/spectroscopy-elemental-isotope-analysis\/molecular-spectroscopy\/fluorometers\/qubit.html?CID=gsd_pcr_sbu_r04_jp_cp0000_pjt0000_gsd00000_0so_blg_op_awa_oc_s00_qpcr49_Social_LAB\" target=\"_blank\" rel=\"noopener noreferrer\">Invitrogen\u2122 Qubit\u2122 Quantitation Platform<\/a> \u306f\u3001DNA\u3001RNA\u307e\u305f\u306f\u30bf\u30f3\u30d1\u30af\u8cea\u306b\u7d50\u5408\u3059\u308b\u3068\u86cd\u5149\u6027\u306b\u306a\u308b\u6700\u5148\u7aef\u306e\u86cd\u5149\u8272\u7d20\u3092\u7528\u3044\u308b\u3001Quant-iT \u86cd\u5149\u6280\u8853\u3092\u4f7f\u7528\u3057\u3066\u3044\u307e\u3059\u3002<a href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/brands\/product-brand\/quant-it.html?CID=gsd_pcr_sbu_r04_jp_cp0000_pjt0000_gsd00000_0so_blg_op_awa_oc_s00_qpcr49_Social_LAB\" target=\"_blank\" rel=\"noopener noreferrer\">Invitrogen\u2122 Quant-iT\u2122 Assay Kit<\/a> \u306f\u7814\u7a76\u5bfe\u8c61\u306e\u5206\u5b50\uff08\u593e\u96d1\u7269\u3092\u542b\u307e\u306a\u3044\uff09\u306e\u6fc3\u5ea6\u306e\u307f\u3092\u6e2c\u5b9a\u3067\u304d\u308b\u305f\u3081\u3001\u7279\u7570\u6027\u304c\u9ad8\u304f\u3001UV\u5438\u53ce\u6e2c\u5b9a\u3088\u308a\u3082\u6b63\u78ba\u306a\u7d50\u679c\u304c\u5f97\u3089\u308c\u307e\u3059\u3002\u3057\u304b\u3082\u3001\u4e00\u822c\u7684\u306b\u86cd\u5149\u8272\u7d20\u3092\u4f7f\u7528\u3059\u308b\u5b9a\u91cf\u6cd5\u306f\u975e\u5e38\u306b\u611f\u5ea6\u304c\u9ad8\u304f\u3001\u5c11\u91cf\u306e\u8a66\u6599\u3057\u304b\u5fc5\u8981\u3068\u3057\u307e\u305b\u3093\u3002<\/p>\n<h2>\u907a\u4f1d\u5b50\u767a\u73fe\u7814\u7a76\u306b\u304a\u3051\u308b\u30b2\u30ce\u30e0DNA\u306e\u6b8b\u5b58<\/h2>\n<p>\u524d\u56de\u306e\u8a18\u4e8b\u306b\u304a\u3044\u3066\u3001\u30d7\u30e9\u30a4\u30de\u30fc\u30c7\u30b6\u30a4\u30f3\u304c\u3001\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u53cd\u5fdc\u306b\u304a\u3044\u3066\u6b8b\u5b58DNA\u7531\u6765\u306e\u5897\u5e45\u3092\u6392\u9664\u3059\u308b\u305f\u3081\u306e\u7b2c\u4e00\u6b69\u3067\u3042\u308b\u3068\u3044\u3046\u3053\u3068\u3092\u3054\u7d39\u4ecb\u3057\u307e\u3057\u305f\u3002<strong>RNA\u306e\u7cbe\u88fd\u6bb5\u968e\u306b\u304a\u3051\u308b\u8a66\u6599\u306eDNase\u51e6\u7406\u306fDNA\u3092\u3082\u3068\u304b\u3089\u30b3\u30f3\u30c8\u30ed\u30fc\u30eb\u3059\u308b\u3053\u3068\u3092\u53ef\u80fd\u3068\u3059\u308b\u65b9\u6cd5\u3067\u3059\u3002<\/strong>\u5f93\u6765\u306eDNase I \u9175\u7d20\u306b\u52a0\u3048\u3066\u3001\u5f53\u793e\u3067\u306f\u3001\u89e6\u5a92\u7684\u306b\u91ce\u751f\u578bDNase I\u3088\u308a\u3082\u512a\u308c\u305f\u3001\u9ad8\u6d3b\u6027<a href=\"https:\/\/www.thermofisher.com\/order\/catalog\/product\/AM2238?CID=gsd_pcr_sbu_r04_jp_cp0000_pjt0000_gsd00000_0so_blg_op_awa_oc_s00_qpcr49_Social_LAB\" target=\"_blank\" rel=\"noopener noreferrer\">Invitrogen\u2122 TURBO\u2122 DNase<\/a> \u3092\u63d0\u4f9b\u3057\u3066\u3044\u307e\u3059\u3002TURBO DNase\u306f\u3001RT-PCR\u306e\u969c\u5bb3\u3068\u306a\u308b\u3054\u304f\u5c11\u91cf\u306eDNA\u3082\u9664\u53bb\u3059\u308b\u3053\u3068\u304c\u53ef\u80fd\u3067\u3059\u3002DNase\u51e6\u7406\u306f\u3001\u7cbe\u88fd\u65b9\u6cd5\u306b\u5fdc\u3058\u3066\u3001\u6eb6\u6db2\u4e2d\u3067\u3082\u30ab\u30e9\u30e0\u4e0a\u3067\u3082\u884c\u3046\u3053\u3068\u304c\u3067\u304d\u307e\u3059\u3002\u30ab\u30e9\u30e0\u4e0a\u3067\u306eDNase\u51e6\u7406\u306b\u306f\u30b7\u30ea\u30ab\u30de\u30c8\u30ea\u30c3\u30af\u30b9\u62bd\u51fa\u3092\u4f7f\u7528\u3059\u308b\u306e\u304c\u4e00\u822c\u7684\u3067\u3001\u5869\u6d17\u6d44\u304c\u9175\u7d20\u81ea\u8eab\u3092\u9664\u53bb\u3059\u308b\u305f\u3081\u3001\u6eb6\u6db2\u4e2d\u306e\u51e6\u7406\u3068\u306f\u7570\u306a\u308a\u3001EDTA\u306e\u5b58\u5728\u4e0b\u3067\u52a0\u71b1\u306b\u3088\u308b\u4e0d\u6d3b\u5316\u3092\u884c\u3046\u5fc5\u8981\u306f\u3042\u308a\u307e\u305b\u3093\u3002\u6b20\u70b9\u3068\u3057\u3066\u306f\u3001\u30ab\u30e9\u30e0\u4e0a\u3067\u306e\u53cd\u5fdc\u306b\u306f\u3088\u308a\u5927\u91cf\u306e\u9175\u7d20\u304c\u5fc5\u8981\u3067\u3059\u3002<\/p>\n<p><strong>\u6eb6\u6db2\u4e2d\u3067\u306eDNase\u53cd\u5fdc\u306f\u3001\u5f93\u676565\u00b0C\u306b\u304a\u3051\u308bDNase\u306e\u52a0\u71b1\u4e0d\u6d3b\u5316\u3092\u5fc5\u8981\u3068\u3057\u307e\u3059\u3002\u53cd\u5fdc\u306b\u5fc5\u8981\u306a\u30de\u30b0\u30cd\u30b7\u30a6\u30e0\u304c\u3001\u3053\u306e\u6e29\u5ea6\u306b\u304a\u3044\u3066\u306f\u30de\u30b0\u30cd\u30b7\u30a6\u30e0\u4f9d\u5b58\u6027\u306eRNA\u52a0\u6c34\u5206\u89e3\u3092\u5f15\u304d\u8d77\u3053\u3059\u53ef\u80fd\u6027\u304c\u3042\u308a\u307e\u3059\u3002<\/strong><a href=\"https:\/\/www.thermofisher.com\/order\/catalog\/product\/AM1906?CID=gsd_pcr_sbu_r04_jp_cp0000_pjt0000_gsd00000_0so_blg_op_awa_oc_s00_qpcr49_Social_LAB\" target=\"_blank\" rel=\"noopener noreferrer\">Invitrogen\u2122 DNA-free\u2122 \u30ad\u30c3\u30c8<\/a>\u304a\u3088\u3073<a href=\"https:\/\/www.thermofisher.com\/order\/catalog\/product\/AM1907?CID=gsd_pcr_sbu_r04_jp_cp0000_pjt0000_gsd00000_0so_blg_op_awa_oc_s00_qpcr49_Social_LAB\" target=\"_blank\" rel=\"noopener noreferrer\">Invitrogen\u2122 TURBO DNA-free\u2122 \u30ad\u30c3\u30c8<\/a>\u306f\u3001\u65b0\u898f\u306eDNase\u4e0d\u6d3b\u6027\u5316\u8a66\u85ac\u3092\u4f7f\u7528\u3057\u3066\u3053\u308c\u3089\u306e\u554f\u984c\u3092\u56de\u907f\u3057\u307e\u3059\u3002DNase\u9175\u7d20\u3092\u53cd\u5fdc\u304b\u3089\u9664\u53bb\u3059\u308b\u306e\u306b\u52a0\u3048\u3066\u3001\u4e0d\u6d3b\u6027\u5316\u8a66\u85ac\u306f\u4e8c\u4fa1\u306e\u967d\u30a4\u30aa\u30f3\u306b\u7d50\u5408\u3057\u53cd\u5fdc\u7de9\u885d\u6db2\u304b\u3089\u9664\u53bb\u3057\u307e\u3059\u3002\u3053\u306e\u305f\u3081\u53cd\u5fdc\u52b9\u7387\u306b\u5f71\u97ff\u3092\u4e0e\u3048\u308b\u53ef\u80fd\u6027\u306e\u3042\u308b\u4e8c\u4fa1\u306e\u967d\u30a4\u30aa\u30f3\u3092RT-PCR\u53cd\u5fdc\u306b\u4f7f\u7528\u3059\u308b\u3053\u3068\u3078\u306e\u6050\u308c\u3092\u6291\u3048\u308b\u3053\u3068\u304c\u3067\u304d\u307e\u3059\u3002<\/p>\n<h2><\/h2>\n<h2>\u3010\u7121\u6599\u516c\u958b\u4e2d\u3011\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u30cf\u30f3\u30c9\u30d6\u30c3\u30af<\/h2>\n<p>\u3053\u306e\u30cf\u30f3\u30c9\u30d6\u30c3\u30af\u3067\u306f\u3001\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u306e\u7406\u8ad6\u3084\u5b9f\u9a13\u30c7\u30b6\u30a4\u30f3\u306e\u8a2d\u8a08\u306a\u3069\u3001\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u306e\u57fa\u790e\u77e5\u8b58\u304c\u63b2\u8f09\u3055\u308c\u3066\u3044\u307e\u3059\u3002\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u3092\u59cb\u3081\u305f\u3070\u304b\u308a\u306e\u65b9\u3084\u3053\u308c\u304b\u3089\u5b9f\u9a13\u3092\u8003\u3048\u3066\u3044\u308b\u65b9\u306b\u3046\u3063\u3066\u3064\u3051\u306e\u30cf\u30f3\u30c9\u30d6\u30c3\u30af\u3067\u3059\u3002PDF\u30d5\u30a1\u30a4\u30eb\u306e\u30c0\u30a6\u30f3\u30ed\u30fc\u30c9\u3092\u3054\u5e0c\u671b\u306e\u65b9\u306f\u3001\u4e0b\u8a18\u30dc\u30bf\u30f3\u3088\u308a\u304a\u7533\u3057\u8fbc\u307f\u304f\u3060\u3055\u3044\u3002<\/p>\n<p><a class=\"btn btn-red\" href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/global\/forms\/real-time-pcr-handbook-form.html?CID=gsd_pcr_sbu_r04_jp_cp0000_pjt0000_gsd00000_0so_blg_op_awa_oc_s00_qpcr49_Social_LAB\" target=\"_blank\" rel=\"noopener\">\u30c0\u30a6\u30f3\u30ed\u30fc\u30c9\u3059\u308b<\/a><\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>\u7814\u7a76\u7528\u306b\u306e\u307f\u4f7f\u7528\u3067\u304d\u307e\u3059\u3002\u8a3a\u65ad\u7528\u306b\u306f\u4f7f\u7528\u3044\u305f\u3060\u3051\u307e\u305b\u3093\u3002<\/p>\n","protected":false},"excerpt":{"rendered":"<p>\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u306b\u7528\u3044\u308b\u6838\u9178\u306e\u7cbe\u88fd\u3092\u884c\u3046\u524d\u306b\u3001\u30b5\u30f3\u30d7\u30eb\u306e\u7a2e\u985e\u304a\u3088\u3073\u9069\u5207\u306a\u7cbe\u88fd\u65b9\u6cd5\u306e\u9078\u629e\u306b\u3064\u3044\u3066\u8003\u5bdf\u3059\u308b\u3053\u3068\u304c\u5fc5\u8981\u3067\u3059\u3002DNA\u304a\u3088\u3073RNA\u5206\u96e2\u6cd5\u306b\u3088\u308a\u3001\u7c21\u4fbf\u6027\u3084\u3001\u6709\u6a5f\u6eb6\u5a92\u306e\u5fc5\u8981\u306e\u6709\u7121\u3001\u304a\u3088\u3073\u56de\u53ce\u3057\u305f\u6838\u9178\u306e\u7d14\u5ea6\u304c\u7570\u306a\u308a\u307e\u3059\u3002\u4eca\u56de\u306f\u3001\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u306b\u7528\u3044\u308b\u6838\u9178\u306e\u7cbe\u88fd\u304a\u3088\u3073\u5b9a\u91cf\u65b9\u6cd5\u306b\u3064\u3044\u3066\u3054\u7d39\u4ecb\u3057\u307e\u3059\u3002<\/p>\n","protected":false},"author":988,"featured_media":3484,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_monsterinsights_skip_tracking":false,"_genesis_hide_title":false,"_genesis_hide_breadcrumbs":false,"_genesis_hide_singular_image":false,"_genesis_hide_footer_widgets":false,"_genesis_custom_body_class":"","_genesis_custom_post_class":"","_genesis_layout":"","_jetpack_newsletter_access":"","_jetpack_dont_email_post_to_subs":false,"_jetpack_newsletter_tier_id":0,"_jetpack_memberships_contains_paywalled_content":false,"_jetpack_feature_clip_id":0,"_jetpack_memberships_contains_paid_content":false,"footnotes":"","jetpack_post_was_ever_published":false},"categories":[156],"tags":[7],"division":[],"class_list":["post-768","post","type-post","status-publish","format-standard","has-post-thumbnail","category-mol-bio","tag-qpcr","entry"],"_selected_authors":"","_selected_reviewers":"","acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v27.8 (Yoast SEO v27.8) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>\u6709\u6a5f\u6eb6\u5a92\uff1f\u305d\u308c\u3068\u3082\u30b7\u30ea\u30ab\u30d9\u30fc\u30b9\uff1f \u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u306b\u304a\u3051\u308b\u6838\u9178\u306e\u7cbe\u88fd\u304a\u3088\u3073\u5b9a\u91cf\u65b9\u6cd5 - Learning at the Bench<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/qpcr-basic43\/\" \/>\n<meta property=\"og:locale\" content=\"ja_JP\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"\u6709\u6a5f\u6eb6\u5a92\uff1f\u305d\u308c\u3068\u3082\u30b7\u30ea\u30ab\u30d9\u30fc\u30b9\uff1f \u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u306b\u304a\u3051\u308b\u6838\u9178\u306e\u7cbe\u88fd\u304a\u3088\u3073\u5b9a\u91cf\u65b9\u6cd5\" \/>\n<meta property=\"og:description\" content=\"\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u306b\u7528\u3044\u308b\u6838\u9178\u306e\u7cbe\u88fd\u3092\u884c\u3046\u524d\u306b\u3001\u30b5\u30f3\u30d7\u30eb\u306e\u7a2e\u985e\u304a\u3088\u3073\u9069\u5207\u306a\u7cbe\u88fd\u65b9\u6cd5\u306e\u9078\u629e\u306b\u3064\u3044\u3066\u8003\u5bdf\u3059\u308b\u3053\u3068\u304c\u5fc5\u8981\u3067\u3059\u3002DNA\u304a\u3088\u3073RNA\u5206\u96e2\u6cd5\u306b\u3088\u308a\u3001\u7c21\u4fbf\u6027\u3084\u3001\u6709\u6a5f\u6eb6\u5a92\u306e\u5fc5\u8981\u306e\u6709\u7121\u3001\u304a\u3088\u3073\u56de\u53ce\u3057\u305f\u6838\u9178\u306e\u7d14\u5ea6\u304c\u7570\u306a\u308a\u307e\u3059\u3002\u4eca\u56de\u306f\u3001\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u306b\u7528\u3044\u308b\u6838\u9178\u306e\u7cbe\u88fd\u304a\u3088\u3073\u5b9a\u91cf\u65b9\u6cd5\u306b\u3064\u3044\u3066\u3054\u7d39\u4ecb\u3057\u307e\u3059\u3002\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/qpcr-basic43\/\" \/>\n<meta property=\"og:site_name\" content=\"Learning at the Bench\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/ThermoFisherJapan\" \/>\n<meta property=\"article:published_time\" content=\"2017-04-06T00:00:00+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2025-04-16T06:22:17+00:00\" \/>\n<meta property=\"og:image\" content=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/qpcr-basic43-title.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"1200\" \/>\n\t<meta property=\"og:image:height\" content=\"630\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"LATB Staff\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:creator\" content=\"@ThermoFisherJP\" \/>\n<meta name=\"twitter:site\" content=\"@ThermoFisherJP\" \/>\n<meta name=\"twitter:label1\" content=\"\u57f7\u7b46\u8005\" \/>\n\t<meta name=\"twitter:data1\" content=\"LATB Staff\" \/>\n\t<meta name=\"twitter:label2\" content=\"\u63a8\u5b9a\u8aad\u307f\u53d6\u308a\u6642\u9593\" \/>\n\t<meta name=\"twitter:data2\" content=\"10\u5206\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/qpcr-basic43\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/qpcr-basic43\\\/\"},\"author\":{\"name\":\"LATB Staff\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#\\\/schema\\\/person\\\/00a095a01d54afcdf9457465feb04f7d\"},\"headline\":\"\u6709\u6a5f\u6eb6\u5a92\uff1f\u305d\u308c\u3068\u3082\u30b7\u30ea\u30ab\u30d9\u30fc\u30b9\uff1f \u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u306b\u304a\u3051\u308b\u6838\u9178\u306e\u7cbe\u88fd\u304a\u3088\u3073\u5b9a\u91cf\u65b9\u6cd5\",\"datePublished\":\"2017-04-06T00:00:00+00:00\",\"dateModified\":\"2025-04-16T06:22:17+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/qpcr-basic43\\\/\"},\"wordCount\":143,\"commentCount\":0,\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/qpcr-basic43\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2019\\\/07\\\/qpcr-basic43-title.jpg\",\"keywords\":[\"\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\"],\"articleSection\":[\"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023\"],\"inLanguage\":\"ja\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/qpcr-basic43\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/qpcr-basic43\\\/\",\"url\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/qpcr-basic43\\\/\",\"name\":\"\u6709\u6a5f\u6eb6\u5a92\uff1f\u305d\u308c\u3068\u3082\u30b7\u30ea\u30ab\u30d9\u30fc\u30b9\uff1f \u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u306b\u304a\u3051\u308b\u6838\u9178\u306e\u7cbe\u88fd\u304a\u3088\u3073\u5b9a\u91cf\u65b9\u6cd5 - Learning at the Bench\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/qpcr-basic43\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/qpcr-basic43\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2019\\\/07\\\/qpcr-basic43-title.jpg\",\"datePublished\":\"2017-04-06T00:00:00+00:00\",\"dateModified\":\"2025-04-16T06:22:17+00:00\",\"author\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#\\\/schema\\\/person\\\/00a095a01d54afcdf9457465feb04f7d\"},\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/qpcr-basic43\\\/#breadcrumb\"},\"inLanguage\":\"ja\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/qpcr-basic43\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"ja\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/qpcr-basic43\\\/#primaryimage\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2019\\\/07\\\/qpcr-basic43-title.jpg\",\"contentUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2019\\\/07\\\/qpcr-basic43-title.jpg\",\"width\":1200,\"height\":630,\"caption\":\"qpcr-basic43-title\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/qpcr-basic43\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"\u6709\u6a5f\u6eb6\u5a92\uff1f\u305d\u308c\u3068\u3082\u30b7\u30ea\u30ab\u30d9\u30fc\u30b9\uff1f \u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u306b\u304a\u3051\u308b\u6838\u9178\u306e\u7cbe\u88fd\u304a\u3088\u3073\u5b9a\u91cf\u65b9\u6cd5\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#website\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/\",\"name\":\"Learning at the Bench\",\"description\":\"\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"ja\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#\\\/schema\\\/person\\\/00a095a01d54afcdf9457465feb04f7d\",\"name\":\"LATB Staff\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"ja\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/8803277856c8b753feb4217dff0f9953327452df1a615c3c88b2f9864efb2ddd?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/8803277856c8b753feb4217dff0f9953327452df1a615c3c88b2f9864efb2ddd?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/8803277856c8b753feb4217dff0f9953327452df1a615c3c88b2f9864efb2ddd?s=96&d=mm&r=g\",\"caption\":\"LATB Staff\"},\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/author\\\/latbstaff\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"\u6709\u6a5f\u6eb6\u5a92\uff1f\u305d\u308c\u3068\u3082\u30b7\u30ea\u30ab\u30d9\u30fc\u30b9\uff1f \u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u306b\u304a\u3051\u308b\u6838\u9178\u306e\u7cbe\u88fd\u304a\u3088\u3073\u5b9a\u91cf\u65b9\u6cd5 - Learning at the Bench","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/qpcr-basic43\/","og_locale":"ja_JP","og_type":"article","og_title":"\u6709\u6a5f\u6eb6\u5a92\uff1f\u305d\u308c\u3068\u3082\u30b7\u30ea\u30ab\u30d9\u30fc\u30b9\uff1f \u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u306b\u304a\u3051\u308b\u6838\u9178\u306e\u7cbe\u88fd\u304a\u3088\u3073\u5b9a\u91cf\u65b9\u6cd5","og_description":"\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u306b\u7528\u3044\u308b\u6838\u9178\u306e\u7cbe\u88fd\u3092\u884c\u3046\u524d\u306b\u3001\u30b5\u30f3\u30d7\u30eb\u306e\u7a2e\u985e\u304a\u3088\u3073\u9069\u5207\u306a\u7cbe\u88fd\u65b9\u6cd5\u306e\u9078\u629e\u306b\u3064\u3044\u3066\u8003\u5bdf\u3059\u308b\u3053\u3068\u304c\u5fc5\u8981\u3067\u3059\u3002DNA\u304a\u3088\u3073RNA\u5206\u96e2\u6cd5\u306b\u3088\u308a\u3001\u7c21\u4fbf\u6027\u3084\u3001\u6709\u6a5f\u6eb6\u5a92\u306e\u5fc5\u8981\u306e\u6709\u7121\u3001\u304a\u3088\u3073\u56de\u53ce\u3057\u305f\u6838\u9178\u306e\u7d14\u5ea6\u304c\u7570\u306a\u308a\u307e\u3059\u3002\u4eca\u56de\u306f\u3001\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u306b\u7528\u3044\u308b\u6838\u9178\u306e\u7cbe\u88fd\u304a\u3088\u3073\u5b9a\u91cf\u65b9\u6cd5\u306b\u3064\u3044\u3066\u3054\u7d39\u4ecb\u3057\u307e\u3059\u3002","og_url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/qpcr-basic43\/","og_site_name":"Learning at the Bench","article_publisher":"https:\/\/www.facebook.com\/ThermoFisherJapan","article_published_time":"2017-04-06T00:00:00+00:00","article_modified_time":"2025-04-16T06:22:17+00:00","og_image":[{"width":1200,"height":630,"url":"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/qpcr-basic43-title.jpg","type":"image\/jpeg"}],"author":"LATB Staff","twitter_card":"summary_large_image","twitter_creator":"@ThermoFisherJP","twitter_site":"@ThermoFisherJP","twitter_misc":{"\u57f7\u7b46\u8005":"LATB Staff","\u63a8\u5b9a\u8aad\u307f\u53d6\u308a\u6642\u9593":"10\u5206"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/qpcr-basic43\/#article","isPartOf":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/qpcr-basic43\/"},"author":{"name":"LATB Staff","@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#\/schema\/person\/00a095a01d54afcdf9457465feb04f7d"},"headline":"\u6709\u6a5f\u6eb6\u5a92\uff1f\u305d\u308c\u3068\u3082\u30b7\u30ea\u30ab\u30d9\u30fc\u30b9\uff1f \u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u306b\u304a\u3051\u308b\u6838\u9178\u306e\u7cbe\u88fd\u304a\u3088\u3073\u5b9a\u91cf\u65b9\u6cd5","datePublished":"2017-04-06T00:00:00+00:00","dateModified":"2025-04-16T06:22:17+00:00","mainEntityOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/qpcr-basic43\/"},"wordCount":143,"commentCount":0,"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/qpcr-basic43\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/qpcr-basic43-title.jpg","keywords":["\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR"],"articleSection":["\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023"],"inLanguage":"ja","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/qpcr-basic43\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/qpcr-basic43\/","url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/qpcr-basic43\/","name":"\u6709\u6a5f\u6eb6\u5a92\uff1f\u305d\u308c\u3068\u3082\u30b7\u30ea\u30ab\u30d9\u30fc\u30b9\uff1f \u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u306b\u304a\u3051\u308b\u6838\u9178\u306e\u7cbe\u88fd\u304a\u3088\u3073\u5b9a\u91cf\u65b9\u6cd5 - Learning at the Bench","isPartOf":{"@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/qpcr-basic43\/#primaryimage"},"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/qpcr-basic43\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/qpcr-basic43-title.jpg","datePublished":"2017-04-06T00:00:00+00:00","dateModified":"2025-04-16T06:22:17+00:00","author":{"@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#\/schema\/person\/00a095a01d54afcdf9457465feb04f7d"},"breadcrumb":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/qpcr-basic43\/#breadcrumb"},"inLanguage":"ja","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/qpcr-basic43\/"]}]},{"@type":"ImageObject","inLanguage":"ja","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/qpcr-basic43\/#primaryimage","url":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/qpcr-basic43-title.jpg","contentUrl":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/qpcr-basic43-title.jpg","width":1200,"height":630,"caption":"qpcr-basic43-title"},{"@type":"BreadcrumbList","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/qpcr-basic43\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/"},{"@type":"ListItem","position":2,"name":"\u6709\u6a5f\u6eb6\u5a92\uff1f\u305d\u308c\u3068\u3082\u30b7\u30ea\u30ab\u30d9\u30fc\u30b9\uff1f \u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u306b\u304a\u3051\u308b\u6838\u9178\u306e\u7cbe\u88fd\u304a\u3088\u3073\u5b9a\u91cf\u65b9\u6cd5"}]},{"@type":"WebSite","@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#website","url":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/","name":"Learning at the Bench","description":"","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"ja"},{"@type":"Person","@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#\/schema\/person\/00a095a01d54afcdf9457465feb04f7d","name":"LATB Staff","image":{"@type":"ImageObject","inLanguage":"ja","@id":"https:\/\/secure.gravatar.com\/avatar\/8803277856c8b753feb4217dff0f9953327452df1a615c3c88b2f9864efb2ddd?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/8803277856c8b753feb4217dff0f9953327452df1a615c3c88b2f9864efb2ddd?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/8803277856c8b753feb4217dff0f9953327452df1a615c3c88b2f9864efb2ddd?s=96&d=mm&r=g","caption":"LATB Staff"},"url":"https:\/\/admin.acceleratingscience.com\/author\/latbstaff\/"}]}},"taxonomy_info":{"category":[{"value":156,"label":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023"}],"post_tag":[{"value":7,"label":"\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR"}]},"featured_image_src_large":["https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/qpcr-basic43-title-1024x538.jpg",760,399,true],"author_info":{"display_name":"LATB Staff","author_link":"https:\/\/admin.acceleratingscience.com\/author\/latbstaff\/"},"comment_info":0,"category_info":[{"term_id":156,"name":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","slug":"mol-bio","term_group":0,"term_taxonomy_id":156,"taxonomy":"category","description":"","parent":0,"count":539,"filter":"raw","meta":[],"cat_ID":156,"category_count":539,"category_description":"","cat_name":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","category_nicename":"mol-bio","category_parent":0}],"tag_info":[{"term_id":7,"name":"\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR","slug":"qpcr","term_group":0,"term_taxonomy_id":7,"taxonomy":"post_tag","description":"","parent":0,"count":91,"filter":"raw","meta":[]}],"jetpack-related-posts":[{"id":25247,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/exosome-gene-expression-ts-r-25018\/","url_meta":{"origin":768,"position":0},"title":"\u3010\u7b2c4\u56de\u3011&#8221;RNA cargo&#8221;\u306e\u7cbe\u88fd\u3068\u5b9a\u91cf\u89e3\u6790\uff5emiRNA\u306e\u5b9a\u91cf\u89e3\u6790\uff5e","author":"LatB Staff","date":"2026\u5e745\u670829\u65e5","format":false,"excerpt":"\u524d\u56de\uff08\u3010\u7b2c3\u56de\u3011\u201cRNA cargo\u201d\u306e\u7cbe\u88fd\u3068\u5b9a\u91cf\u89e3\u6790\uff09\u3067\u306f\u3001\u30a8\u30af\u30bd\u30bd\u30fc\u30e0 \uff08\u30a8\u30ad\u30bd\u30bd\u30fc\u30e0\uff09 \u304b\u3089\u306e\u2026","rel":"","context":"\u5206\u6790\u30fb\u6e2c\u5b9a\u95a2\u9023","block_context":{"text":"\u5206\u6790\u30fb\u6e2c\u5b9a\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/analysis\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25018_eyecatch-1.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25018_eyecatch-1.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25018_eyecatch-1.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25018_eyecatch-1.jpg?resize=700%2C400&ssl=1 2x"},"classes":[]},{"id":25325,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/exosome-gene-expression-ts-r-25019\/","url_meta":{"origin":768,"position":1},"title":"\u3010\u7b2c5\u56de\u3011 &#8220;RNA cargo&#8221;\u306e\u7cbe\u88fd\u3068\u5b9a\u91cf\u89e3\u6790\u300d\uff5emRNA\u306e\u5b9a\u91cf\u89e3\u6790\uff5e","author":"LatB Staff","date":"2026\u5e746\u670811\u65e5","format":false,"excerpt":"\u4eca\u56de\u306f\u3001\u30a8\u30af\u30bd\u30bd\u30fc\u30e0\uff08\u30a8\u30ad\u30bd\u30bd\u30fc\u30e0\uff09\u4e2d\u306emRNA\u306e\u5b9a\u91cf\u89e3\u6790\u306b\u3064\u3044\u3066\u8aac\u660e\u3057\u307e\u3059\u3002\u7b2c3\u56de\u3067\u30a8\u30af\u30bd\u30bd\u30fc\u30e0\u304b\u2026","rel":"","context":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","block_context":{"text":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/mol-bio\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25018_eyecatch-1.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25018_eyecatch-1.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25018_eyecatch-1.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25018_eyecatch-1.jpg?resize=700%2C400&ssl=1 2x"},"classes":[]},{"id":25565,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/exosome-antibody-ts-r-25068\/","url_meta":{"origin":768,"position":2},"title":"\u3010\u7b2c8\u56de\u3011\u30a8\u30af\u30bd\u30bd\u30fc\u30e0\u30b5\u30d6\u30bf\u30a4\u30d7\u306e\u5206\u753b\u6cd5 \uff1a \u30a6\u30a7\u30b9\u30bf\u30f3\u30d6\u30ed\u30c3\u30c8\uff0fqRT-PCR\uff0f\u30b7\u30fc\u30b1\u30f3\u30b9\u89e3\u6790\u306b\u9069\u3057\u305f\u5206\u753b\u65b9\u6cd5","author":"LatB Staff","date":"2026\u5e749\u670829\u65e5","format":false,"excerpt":"\u672c\u7a3f\u3067\u306f\u3001\u30a8\u30af\u30bd\u30bd\u30fc\u30e0\u819c\u4e0a\u306e\u7279\u5b9a\u306e\u30bf\u30f3\u30d1\u30af\u8cea\u3092\u6a19\u7684\u3068\u3057\u305f\u514d\u75ab\u5438\u7740\u6cd5\u306b\u57fa\u3065\u304f\u5206\u753b\u624b\u6cd5\u3092\u7d39\u4ecb\u3057\u307e\u3059\u3002\u30a8\u30af\u2026","rel":"","context":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","block_context":{"text":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/mol-bio\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25019_eyecatch.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25019_eyecatch.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25019_eyecatch.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25019_eyecatch.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25019_eyecatch.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25019_eyecatch.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":20152,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/exosome-nucleic-acid-purification-ts-r-25017\/","url_meta":{"origin":768,"position":3},"title":"\u3010\u7b2c3\u56de\u3011\u201cRNA cargo\u201d\u306e\u7cbe\u88fd\u3068\u5b9a\u91cf\u89e3\u6790","author":"LatB Staff","date":"2026\u5e745\u670813\u65e5","format":false,"excerpt":"\u7b2c2\u56de\u3067\u306f\u3001\u57f9\u990a\u4e0a\u6e05\u3084\u3055\u307e\u3056\u307e\u306a\u4f53\u6db2\u30b5\u30f3\u30d7\u30eb\u304b\u3089\u306e\u30a8\u30af\u30bd\u30bd\u30fc\u30e0\u306e\u6fc3\u7e2e\u30fb\u56de\u53ce\u65b9\u6cd5\u306b\u3064\u3044\u3066\u7d39\u4ecb\u3057\u307e\u3057\u305f\u304c\u2026","rel":"","context":"\u305d\u306e\u4ed6","block_context":{"text":"\u305d\u306e\u4ed6","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/else\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/f17931341a23d82235760ed66ded9c41.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/f17931341a23d82235760ed66ded9c41.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/f17931341a23d82235760ed66ded9c41.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/f17931341a23d82235760ed66ded9c41.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/f17931341a23d82235760ed66ded9c41.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/f17931341a23d82235760ed66ded9c41.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":20124,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/exosome-gene-therapy-ts-r-25015\/","url_meta":{"origin":768,"position":4},"title":"\u3010\u7b2c1\u56de\u3011Exosome\uff08\u30a8\u30af\u30bd\u30bd\u30fc\u30e0\uff0f\u30a8\u30ad\u30bd\u30bd\u30fc\u30e0\uff09\u3068\u306f\uff1f","author":"LatB Staff","date":"2026\u5e744\u670815\u65e5","format":false,"excerpt":"Exosome\uff08\u30a8\u30af\u30bd\u30bd\u30fc\u30e0\uff0f\u30a8\u30ad\u30bd\u30bd\u30fc\u30e0\uff09\u306e\u7814\u7a76\u304c\u6ce8\u76ee\u3092\u96c6\u3081\u3066\u3044\u307e\u3059\u3002\u8208\u5473\u306f\u3042\u3063\u3066\u3082\u3001\u3069\u306e\u3088\u3046\u306b\u7814\u2026","rel":"","context":"\u305d\u306e\u4ed6","block_context":{"text":"\u305d\u306e\u4ed6","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/else\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/03\/6fae859c8c1eacdaa39f3ae843ae1bda-scaled.png?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/03\/6fae859c8c1eacdaa39f3ae843ae1bda-scaled.png?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/03\/6fae859c8c1eacdaa39f3ae843ae1bda-scaled.png?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/03\/6fae859c8c1eacdaa39f3ae843ae1bda-scaled.png?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/03\/6fae859c8c1eacdaa39f3ae843ae1bda-scaled.png?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/03\/6fae859c8c1eacdaa39f3ae843ae1bda-scaled.png?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":24187,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/ngs-gene-expression-csd-ts-ion-25073\/","url_meta":{"origin":768,"position":5},"title":"\u3010\u3084\u3063\u3066\u307f\u305f\u3011\u5fae\u91cf\u30fb\u5206\u89e3RNA\u306b\u3088\u308b\u767a\u73fe\u89e3\u6790\u306e\u6700\u9069\u89e3\u306f\uff1fRNA-Seq\u3068Ion AmpliSeq Transcriptome\u3092\u6bd4\u3079\u3066\u307f\u305f","author":"LatB Staff","date":"2025\u5e7411\u670828\u65e5","format":false,"excerpt":"\u6b21\u4e16\u4ee3\u30b7\u30fc\u30b1\u30f3\u30b5\u3067\u306e\u767a\u73fe\u89e3\u6790\u306b\u53d6\u308a\u7d44\u3080\u969b\u3001RNA\u30b5\u30f3\u30d7\u30eb\u304c\u300c\u5c11\u306a\u3059\u304e\u308b\u300d\u300c\u5206\u89e3\u3057\u3066\u3044\u308b\u300d\u3068\u3044\u3046\u72b6\u6cc1\u306f\u2026","rel":"","context":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","block_context":{"text":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/mol-bio\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/11\/ngs-gene-expression-csd-ts-ion-25073_eyecatch-scaled.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/11\/ngs-gene-expression-csd-ts-ion-25073_eyecatch-scaled.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/11\/ngs-gene-expression-csd-ts-ion-25073_eyecatch-scaled.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/11\/ngs-gene-expression-csd-ts-ion-25073_eyecatch-scaled.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/11\/ngs-gene-expression-csd-ts-ion-25073_eyecatch-scaled.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/11\/ngs-gene-expression-csd-ts-ion-25073_eyecatch-scaled.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]}],"jetpack_sharing_enabled":true,"amp_enabled":true,"jetpack_featured_media_url":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/qpcr-basic43-title.jpg","_links":{"self":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/posts\/768","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/users\/988"}],"replies":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/comments?post=768"}],"version-history":[{"count":0,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/posts\/768\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/media\/3484"}],"wp:attachment":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/media?parent=768"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/categories?post=768"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/tags?post=768"},{"taxonomy":"division","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/division?post=768"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}