{"id":777,"date":"2017-04-11T00:00:00","date_gmt":"2017-04-11T00:00:00","guid":{"rendered":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/qpcr-basic44\/"},"modified":"2025-04-16T15:22:09","modified_gmt":"2025-04-16T06:22:09","slug":"qpcr-basic44","status":"publish","type":"post","link":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/qpcr-basic44\/","title":{"rendered":"1-Step qRT-PCR\u30682-Step qRT-PCR\u306e\u5229\u70b9\u3068\u6b20\u70b9\u3068\u306f\uff1f \u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u306e\u9006\u8ee2\u5199\u53cd\u5fdc\u306b\u304a\u3044\u3066\u6c17\u3092\u3064\u3051\u308b\u3079\u304d\u30dd\u30a4\u30f3\u30c8"},"content":{"rendered":"<h2>\u9006\u8ee2\u5199\u9175\u7d20\u3068\u306f\uff1f<\/h2>\n<p>\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u306b\u4f7f\u7528\u3055\u308c\u308b\u9006\u8ee2\u5199\u9175\u7d20\u306e\u5927\u90e8\u5206\u306f\u3001\u30c8\u30ea\u9aa8\u9ac4\u82bd\u7403\u75c7\u30a6\u30a4\u30eb\u30b9\uff08AMV\uff09\u307e\u305f\u306f\u30e2\u30ed\u30cb\u30fc\u30de\u30a6\u30b9\u767d\u8840\u75c5\u30a6\u30a4\u30eb\u30b9\uff08M-MLV\uff09\u7531\u6765\u3067\u3059\u3002\u5929\u7136\u306eAMV\u9006\u8ee2\u5199\u9175\u7d20\u306f\u4e00\u822c\u7684\u306bM-MLV\u3088\u308a\u3082\u71b1\u5b89\u5b9a\u6027\u3067\u3059\u304c\u53ce\u91cf\u306f\u4f4e\u304f\u306a\u308a\u307e\u3059\u3002\u3057\u304b\u3057\u3001\u5929\u7136\u578b\u306e\u9175\u7d20\u3092\u6539\u5909\u3059\u308b\u3053\u3068\u306b\u3088\u308a\u3001\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u306b\u3068\u3063\u3066\u7406\u60f3\u7684\u306a\u6027\u8cea\u3092\u6709\u3059\u308b\u5909\u7570\u4f53\u304c\u5f97\u3089\u308c\u307e\u3059\u3002<strong>\u7406\u60f3\u7684\u306a\u9006\u8ee2\u5199\u9175\u7d20\u306b\u306f\u4ee5\u4e0b\u306e\u3088\u3046\u306a\u6027\u8cea\u304c\u5099\u308f\u3063\u3066\u3044\u307e\u3059\u3002<\/strong><\/p>\n<ul>\n<li><strong>\u71b1\u5b89\u5b9a\u6027<\/strong>\uff1a\u4e8c\u6b21\u69cb\u9020\u306f\u53cd\u5fdc\u306e\u611f\u5ea6\u306b\u5927\u304d\u306a\u5f71\u97ff\u3092\u4e0e\u3048\u307e\u3059\u3002\u5929\u7136\u578b\u306eRT\u306e\u6027\u80fd\u306b\u7406\u60f3\u7684\u306a\u6e29\u5ea6\u306f42\u00b0C\u304b\u308950\u00b0C\u306e\u9593\u3067\u3059\u304c\u3001\u71b1\u5b89\u5b9a\u578b\u306eRT\u306f\u3053\u306e\u6e29\u5ea6\u7bc4\u56f2\u306e\u9ad8\u6e29\u57df\uff08\u3042\u308b\u3044\u306f\u305d\u308c\u4ee5\u4e0a\u306e\u6e29\u5ea6\uff09\u306b\u304a\u3044\u3066\u6a5f\u80fd\u3057\u3001GC\u542b\u91cf\u306e\u9ad8\u3044\u9818\u57df\u306e\u9006\u8ee2\u5199\u3082\u53ef\u80fd\u3067\u3059\u3002<\/li>\n<li><strong>RNase H\u6d3b\u6027<\/strong>\uff1aRNase H\u30c9\u30e1\u30a4\u30f3\u306f\u901a\u5e38\u306e\u5929\u7136\u578b\u9006\u8ee2\u5199\u9175\u7d20\u306b\u5b58\u5728\u3057\u3001in vivo \u3067\u6b21\u306e\u8907\u88fd\u6bb5\u968e\u306e\u305f\u3081\u306bRNA-DNA\u30d8\u30c6\u30ed\u4e8c\u91cf\u4f53\u306eRNA\u3092\u89e3\u96e2\u3059\u308b\u305f\u3081\u306b\u6a5f\u80fd\u3057\u307e\u3059\u3002\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u306b\u304a\u3044\u3066\u306f\u3001RNase H\u6d3b\u6027\u306b\u3088\u308a\u53ce\u91cf\u304a\u3088\u3073\u5b8c\u5168\u9577\u306ecDNA\u306e\u5272\u5408\u304c\u5927\u304d\u304f\u4f4e\u4e0b\u3059\u308b\u53ef\u80fd\u6027\u304c\u3042\u308a\u3001\u611f\u5ea6\u306e\u4f4e\u4e0b\u306b\u3064\u306a\u304c\u308a\u307e\u3059\u3002RNase H\u6d3b\u6027\u3092\u4f4e\u4e0b\u3055\u305b\u305fRT\u304c\u3044\u304f\u3064\u304b\u958b\u767a\u3055\u308c\u3066\u304a\u308a\u3001\u4e2d\u3067\u3082<a href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/life-science\/pcr\/reverse-transcription\/reverse-transcriptase-enzymes.html?CID=gsd_pcr_sbu_r04_jp_cp0000_pjt0000_gsd00000_0so_blg_op_awa_oc_s00_qpcr50_Social_LAB\" target=\"_blank\" rel=\"noopener noreferrer\">Invitrogen\u2122 SuperScript\u2122 III\u304a\u3088\u3073IV<\/a>\u304c\u6700\u3082\u512a\u308c\u3066\u3044\u307e\u3059\u3002<\/li>\n<\/ul>\n<h2>1-Step qRT-PCR\u304a\u3088\u30732-Step qRT-PCR<\/h2>\n<p><strong>1-Step qRT-PCR\u3092\u9078\u629e\u3059\u308b\u304b2-Step qRT-PCR\u3092\u9078\u629e\u3059\u308b\u304b\u306f\u3001\u7c21\u4fbf\u6027\u3001\u611f\u5ea6\u304a\u3088\u3073\u30a2\u30c3\u30bb\u30a4\u30c7\u30b6\u30a4\u30f3\u306b\u3088\u308a\u5de6\u53f3\u3055\u308c\u307e\u3059\u3002<\/strong>\u5404\u5b9f\u9a13\u306b\u95a2\u3057\u3066\u3001\u305d\u308c\u305e\u308c\u306e\u65b9\u6cd5\u306e\u5229\u70b9\u304a\u3088\u3073\u6b20\u70b9\u3092\u8a55\u4fa1\u3059\u308b\u5fc5\u8981\u304c\u3042\u308a\u307e\u3059\u3002<\/p>\n<p><strong>1-Step\u53cd\u5fdc\u306b\u304a\u3044\u3066\u306f\u3001\u9006\u8ee2\u5199\u306e\u9593\u306f\u9006\u8ee2\u5199\u9175\u7d20\u3068\u71b1\u5b89\u5b9a\u6027DNA\u30dd\u30ea\u30e1\u30e9\u30fc\u30bc\u306e\u4e21\u65b9\u304c\u5b58\u5728\u3057\u3001\u9ad8\u6e29\u306eDNA\u30dd\u30ea\u30e1\u30e9\u30fc\u30bc\u6d3b\u6027\u5316\u6bb5\u968e\uff08\u3044\u308f\u3086\u308b\u30db\u30c3\u30c8\u30b9\u30bf\u30fc\u30c8\uff09\u306b\u304a\u3044\u3066RT\u304c\u4e0d\u6d3b\u6027\u5316\u3055\u308c\u307e\u3059\u3002<\/strong>\u901a\u5e38\u3001RT\u306b\u306fDNA\u30dd\u30ea\u30e1\u30e9\u30fc\u30bc\u306b\u3068\u3063\u3066\u6700\u9069\u3067\u306f\u306a\u3044\u30d0\u30c3\u30d5\u30a1\u30fc\u304c\u9069\u3057\u3066\u3044\u307e\u3059\u3002\u3053\u306e\u305f\u3081\u30011-Step \u53cd\u5fdc\u306e\u30d0\u30c3\u30d5\u30a1\u30fc\u306f\u4e21\u65b9\u306e\u9175\u7d20\u306b\u95a2\u3057\u3066\u3001\u8a31\u5bb9\u53ef\u80fd\u3067\u306f\u3042\u308b\u3051\u308c\u3069\u6700\u9069\u3068\u306f\u3044\u3048\u306a\u3044\u6a5f\u80fd\u6027\u3092\u4f9b\u7d66\u3059\u308b\u3001\u59a5\u5354\u7684\u306a\u30bd\u30ea\u30e5\u30fc\u30b7\u30e7\u30f3\u3068\u306a\u3063\u3066\u3044\u307e\u3059\u3002\u3053\u306e\u6a5f\u80fd\u6027\u306e\u308f\u305a\u304b\u306a\u4f4e\u4e0b\u306f\u3001\u5358\u4e00\u30c1\u30e5\u30fc\u30d6\u5185\u3067\u3059\u3079\u3066\u306ecDNA\u7523\u7269\u304cPCR\u6bb5\u968e\u3067\u5897\u5e45\u3055\u308c\u308b\u3068\u3044\u3046\u5229\u70b9\u306b\u3088\u308a\u88dc\u308f\u308c\u307e\u3059\u3002<\/p>\n<p><strong>2-Step qRT-PCR\u306b\u304a\u3044\u3066\u306f\u3001\u9006\u8ee2\u5199\u306f\u9006\u8ee2\u5199\u7528\u306b\u6700\u9069\u5316\u3055\u308c\u305f\u30d0\u30c3\u30d5\u30a1\u30fc\u4e2d\u3067\u884c\u308f\u308c\u307e\u3059\u3002<\/strong>\u9006\u8ee2\u5199\u304c\u5b8c\u4e86\u3059\u308b\u3068\u3001\u7d0410%\u306ecDNA\u3092PCR\u7528\u306b\u6700\u9069\u5316\u3055\u308c\u305f\u30d0\u30c3\u30d5\u30a1\u30fc\u4e2d\u3067\u306e\u5404\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u53cd\u5fdc\u306b\u79fb\u884c\u3067\u304d\u307e\u3059\u3002<\/p>\n<h3>1-Step qRT-PCR\u306e\u5229\u70b9<\/h3>\n<ul>\n<li style=\"list-style-type: none\">\n<ul>\n<li><strong>\u30b3\u30f3\u30bf\u30df\u30cd\u30fc\u30b7\u30e7\u30f3\u306e\u9632\u6b62<\/strong>\uff1a\u5358\u72ec\u30c1\u30e5\u30fc\u30d6\u5185\u3067\u9023\u7d9a\u3057\u3066\u53cd\u5fdc\u3059\u308b\u306e\u3067\u3001RT\u6bb5\u968e\u3068PCR\u6bb5\u968e\u306e\u9593\u3067\u306e\u6c5a\u67d3\u7269\u8cea\u306e\u30b3\u30f3\u30bf\u30df\u9632\u6b62\u3055\u308c\u307e\u3059\u3002<\/li>\n<li><strong>\u7c21\u4fbf\u6027<\/strong>\uff1a\u30d4\u30da\u30c3\u30c6\u30a4\u30f3\u30b0\u30b9\u30c6\u30c3\u30d7\u6570\u304c\u6e1b\u5c11\u3057\u3001\u30cf\u30f3\u30ba\u30aa\u30f3\u6642\u9593\u304c\u6700\u5c0f\u9650\u306b\u6291\u3048\u3089\u308c\u307e\u3059\u3002<\/li>\n<li><strong>\u30cf\u30a4\u30b9\u30eb\u30fc\u30d7\u30c3\u30c8\u306e\u30b5\u30f3\u30d7\u30eb\u30b9\u30af\u30ea\u30fc\u30cb\u30f3\u30b0<\/strong>\uff1a\u7406\u7531\u306f\u5148\u8ff0\u3057\u305f\u3068\u304a\u308a\u3067\u3059\u3002<\/li>\n<\/ul>\n<\/li>\n<\/ul>\n<ul>\n<li><strong>\u611f\u5ea6<\/strong>\uff1a1-Step\u53cd\u5fdc\u306b\u304a\u3044\u3066\u306f\u751f\u6210\u3057\u305fcDNA\u304c\u3059\u3079\u3066\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u5897\u5e45\u306b\u5229\u7528\u3055\u308c\u308b\u305f\u3081\u30012-Step\u53cd\u5fdc\u3068\u6bd4\u8f03\u3057\u3066\u3088\u308a\u611f\u5ea6\u304c\u9ad8\u304f\u306a\u308b\u53ef\u80fd\u6027\u304c\u3042\u308a\u307e\u3059\u3002<\/li>\n<\/ul>\n<h3>1-Step qRT-PCR\u306e\u6b20\u70b9<\/h3>\n<ul>\n<li><strong>\u30d7\u30e9\u30a4\u30de\u30fc\u30c0\u30a4\u30de\u30fc\u306e\u751f\u6210\u53ef\u80fd\u6027\u306e\u5897\u52a0<\/strong>\uff1a1-Step\u53cd\u5fdc\u306e\u521d\u671f\u304b\u3089\u5b58\u5728\u3059\u308b\u30d5\u30a9\u30ef\u30fc\u30c9\u304a\u3088\u3073\u30ea\u30d0\u30fc\u30b9\u306e\u907a\u4f1d\u5b50\u7279\u7570\u7684\u30d7\u30e9\u30a4\u30de\u30fc\u306f\u3001\u9006\u8ee2\u5199\u6761\u4ef6\u3067\u3042\u308b42\u00b0C\uff5e50\u00b0C\u306e\u6e29\u5ea6\u7bc4\u56f2\u3067\u30c0\u30a4\u30de\u30fc\u3092\u5f62\u6210\u3059\u308b\u53ef\u80fd\u6027\u304c\u3088\u308a\u9ad8\u304f\u306a\u308a\u307e\u3059\u3002\u3053\u308c\u306f\u3001DNA\u7d50\u5408\u8272\u7d20\u3092\u691c\u51fa\u306b\u4f7f\u7528\u3059\u308b\u969b\u306b\u306f\u7279\u306b\u554f\u984c\u3067\u3059\u3002<\/li>\n<li><strong>cDNA\u3092\u4ed6\u306e\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u53cd\u5fdc\u306b\u4f7f\u7528\u3059\u308b\u3053\u3068\u304c\u4e0d\u53ef\u80fd<\/strong>\uff1a1-Step\u53cd\u5fdc\u3067\u306f\u3001RT\u30b9\u30c6\u30c3\u30d7\u304b\u3089\u306ecDNA\u304c\u3059\u3079\u3066\u4f7f\u7528\u3055\u308c\u307e\u3059\u3002\u3053\u306e\u305f\u3081\u3001\u53cd\u5fdc\u306b\u5931\u6557\u3059\u308b\u3068\u3059\u3079\u3066\u306e\u8a66\u6599\u304c\u5931\u308f\u308c\u3066\u3057\u307e\u3044\u307e\u3059\u3002<\/li>\n<\/ul>\n<h3>2-Step qRT-PCR\u306e\u5229\u70b9<\/h3>\n<ul>\n<li><strong>cDNA\u3092\u4fdd\u5b58\u3057\u3066\u3055\u3089\u306b\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u53cd\u5fdc\u3092\u884c\u3046\u3053\u3068\u304c\u53ef\u80fd<\/strong>\uff1a2-Step qRT-PCR\u3067\u306f\u8907\u6570\u56de\u306eqRT-PCR\u53cd\u5fdc\u306b\u5341\u5206\u306a\u91cf\u306ecDNA\u3092\u5408\u6210\u3057\u307e\u3059\u306e\u3067\u3001\u30ec\u30a2\u306a\u8a66\u6599\u307e\u305f\u306f\u91cf\u306e\u9650\u3089\u308c\u305f\u8a66\u6599\u306b\u306f\u6700\u9069\u3067\u3059\u3002<\/li>\n<li><strong>\u611f\u5ea6<\/strong>\uff1a2-Step\u53cd\u5fdc\u306b\u304a\u3044\u3066\u306f\u3001RT\u3068PCR\u53cd\u5fdc\u306f\u305d\u308c\u305e\u308c\u500b\u5225\u306b\u6700\u9069\u5316\u3055\u308c\u305f\u30d0\u30c3\u30d5\u30a1\u30fc\u4e2d\u3067\u884c\u308f\u308c\u308b\u305f\u3081\u30011-Step\u53cd\u5fdc\u3068\u6bd4\u8f03\u3057\u3066\u3088\u308a\u611f\u5ea6\u304c\u9ad8\u304f\u306a\u308b\u53ef\u80fd\u6027\u304c\u3042\u308a\u307e\u3059\u3002<\/li>\n<li><strong>\u8907\u6570\u306e\u30bf\u30fc\u30b2\u30c3\u30c8<\/strong>\uff1a\u4f7f\u7528\u3059\u308bRT\u30d7\u30e9\u30a4\u30de\u30fc\u306b\u3088\u3063\u3066\u306f\u3001\u5358\u4e00\u306eRNA\u8a66\u6599\u304b\u3089\u8907\u6570\u306e\u30bf\u30fc\u30b2\u30c3\u30c8\u306e\u89e3\u6790\u3092\u884c\u3046\u3053\u3068\u304c\u53ef\u80fd\u3067\u3059\u3002<\/li>\n<\/ul>\n<h3>2-Step qRT-PCR\u306e\u6b20\u70b9<\/h3>\n<ul>\n<li><strong>RT\u9175\u7d20\u304a\u3088\u3073\u30d0\u30c3\u30d5\u30a1\u30fc\u304c\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u3092\u963b\u5bb3\u3059\u308b\u53ef\u80fd\u6027<\/strong>\uff1a\u901a\u5e38\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u53cd\u5fdc\u306bcDNA\u5408\u6210\u53cd\u5fdc\u6db2\u309210\uff05\u7a0b\u5ea6\u4f7f\u7528\u3057\u307e\u3059\u304c\u3001\u3053\u308c\u306f\u9069\u6b63\u306b\u5e0c\u91c8\u3092\u884c\u308f\u306a\u3044\u3068\u3001RT\u304a\u3088\u3073\u95a2\u9023\u3059\u308b\u30d0\u30c3\u30d5\u30a1\u30fc\u6210\u5206\u304cDNA\u30dd\u30ea\u30e1\u30e9\u30fc\u30bc\u3092\u963b\u5bb3\u3059\u308b\u53ef\u80fd\u6027\u304c\u3042\u308b\u305f\u3081\u3067\u3059\u3002<\/li>\n<li><strong>\u7c21\u4fbf\u6027\u304c\u4f4e\u3044<\/strong>\uff1a2-Step\u53cd\u5fdc\u306b\u306f\u3088\u308a\u591a\u304f\u306e\u64cd\u4f5c\u304c\u5fc5\u8981\u3067\u3042\u308a\u3001\u30cf\u30a4\u30b9\u30eb\u30fc\u30d7\u30c3\u30c8\u30a2\u30d7\u30ea\u30b1\u30fc\u30b7\u30e7\u30f3\u3078\u306e\u9069\u5fdc\u6027\u304c\u3088\u308a\u4f4e\u304f\u306a\u308a\u307e\u3059\u3002<\/li>\n<li><strong>\u30b3\u30f3\u30bf\u30df\u30cd\u30fc\u30b7\u30e7\u30f3\u306e\u5371\u967a\u6027<\/strong>\uff1a\u5404\u30b9\u30c6\u30c3\u30d7\u306b\u7570\u306a\u308b\u30c1\u30e5\u30fc\u30d6\u3092\u4f7f\u7528\u3059\u308b\u305f\u3081\u3001\u30b3\u30f3\u30bf\u30df\u30cd\u30fc\u30b7\u30e7\u30f3\u306e\u5371\u967a\u5ea6\u304c\u5897\u3057\u307e\u3059\u3002<\/li>\n<\/ul>\n<h2>RNA\u30d7\u30e9\u30a4\u30df\u30f3\u30b0\u6cd5<\/h2>\n<p><strong>\u9006\u8ee2\u5199\u306fqRT-PCR\u53cd\u5fdc\u306b\u304a\u3044\u3066\u6700\u3082\u5909\u52d5\u8981\u56e0\u304c\u591a\u3044\u5de5\u7a0b\u3067\u3059\u3002<\/strong>cDNA\u306e\u5408\u6210\u53cd\u5fdc\u306b\u306f\u907a\u4f1d\u5b50\u7a2e\u3001\u30aa\u30ea\u30b4\uff08dT\uff09\u307e\u305f\u306f\u30e9\u30f3\u30c0\u30e0\u30d7\u30e9\u30a4\u30de\u30fc\u304c\u4f7f\u7528\u53ef\u80fd\u3067\uff08\u56f3\uff09\u3001\u30d7\u30e9\u30a4\u30de\u30fc\u306e\u9078\u629e\u304cRT\u52b9\u7387\u304a\u3088\u3073\u4e00\u8cab\u6027\u3001\u305d\u3057\u3066\u305d\u306e\u7d50\u679c\u3068\u3057\u3066\u30c7\u30fc\u30bf\u306e\u7cbe\u5ea6\u306b\u5927\u304d\u306a\u5f71\u97ff\u3092\u4e0e\u3048\u307e\u3059\u3002<\/p>\n<p><strong>\u30e9\u30f3\u30c0\u30e0\u30d7\u30e9\u30a4\u30de\u30fc\u306f\u591a\u304f\u306ecDNA\u306e\u5408\u6210\u306b\u9069\u3057\u3066\u304a\u308a\u3001\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u306b\u304a\u3044\u3066\u6700\u9ad8\u306e\u611f\u5ea6\u3092\u63d0\u4f9b\u3059\u308b\u3053\u3068\u304c\u53ef\u80fd\u3067\u3059\u3002<\/strong>\u30e9\u30f3\u30c0\u30e0\u30d7\u30e9\u30a4\u30de\u30fc\u306f\u307e\u305f\u3001\u7d30\u83cc\u6027RNA\u306a\u3069\u306e\u975e\u30a2\u30c7\u30cb\u30eb\u5316RNA\u306b\u304a\u3044\u3066\u3082\u7406\u60f3\u7684\u3067\u3059\u3002\u30e9\u30f3\u30c0\u30e0\u30d7\u30e9\u30a4\u30de\u30fc\u306f\u30bf\u30fc\u30b2\u30c3\u30c8\u5206\u5b50\u5168\u4f53\u306b\u30a2\u30cb\u30fc\u30eb\u3059\u308b\u305f\u3081\u3001\u5206\u89e3\u3057\u305f\u8ee2\u5199\u7523\u7269\u3084\u4e8c\u6b21\u69cb\u9020\u304c\u5b58\u5728\u3057\u3066\u3044\u3066\u3082\u907a\u4f1d\u5b50\u7279\u7570\u7684\u30d7\u30e9\u30a4\u30de\u30fc\u3084\u30aa\u30ea\u30b4\uff08dT\uff09\u30d7\u30e9\u30a4\u30de\u30fc\u306e\u5834\u5408\u307b\u3069\u5927\u304d\u306a\u554f\u984c\u306b\u306f\u306a\u308a\u307e\u305b\u3093\u3002<\/p>\n<p>\u53ce\u91cf\u306e\u5411\u4e0a\u306f\u671b\u307e\u3057\u3044\u3053\u3068\u3067\u3059\u304c\u3001<strong>\u30e9\u30f3\u30c0\u30e0\u30d7\u30e9\u30a4\u30de\u30fc\u3067\u306f\u30b3\u30d4\u30fc\u6570\u3092\u904e\u5927\u8a55\u4fa1\u3057\u3066\u3057\u307e\u3046\u53ef\u80fd\u6027\u304c\u3042\u308b\u3053\u3068\u304c\u30c7\u30fc\u30bf\u304b\u3089\u793a\u3055\u308c\u3066\u3044\u307e\u3059\u3002<\/strong>\u30e9\u30f3\u30c0\u30e0\u30d7\u30e9\u30a4\u30de\u30fc\u3068\u30aa\u30ea\u30b4\uff08dT\uff09\u30d7\u30e9\u30a4\u30de\u30fc\u306e\u7d44\u307f\u5408\u308f\u305b\u3092\u5229\u7528\u3059\u308b\u3053\u3068\u3067\u3001\u540c\u4e00\u306eRT\u53cd\u5fdc\u306b\u304a\u3044\u3066\u4e21\u8005\u306e\u9577\u6240\u3092\u7d44\u307f\u5408\u308f\u305b\u308b\u3053\u3068\u306b\u3088\u308a\u3001\u30c7\u30fc\u30bf\u306e\u54c1\u8cea\u3092\u5411\u4e0a\u3055\u305b\u308b\u3053\u3068\u304c\u53ef\u80fd\u306a\u5834\u5408\u3082\u3042\u308a\u307e\u3059\u3002\u30e9\u30f3\u30c0\u30e0\u30d7\u30e9\u30a4\u30de\u30fc\u306f2-Step\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u306b\u304a\u3044\u3066\u306e\u307f\u4f7f\u7528\u3055\u308c\u307e\u3059\u3002<\/p>\n<p><strong>\u30aa\u30ea\u30b4\uff08dT\uff09\u30d7\u30e9\u30a4\u30de\u30fc\u306f\u3001\u305d\u306emRNA\u3078\u306e\u7279\u7570\u6027\u304a\u3088\u3073\u540c\u4e00\u306ecDNA\u30d7\u30fc\u30eb\u304b\u3089\u591a\u304f\u306e\u7570\u306a\u308b\u30bf\u30fc\u30b2\u30c3\u30c8\u3092\u89e3\u6790\u3059\u308b\u3053\u3068\u304c\u53ef\u80fd\u3067\u3042\u308b\u3053\u3068\u304b\u3089\u30012-Step \u53cd\u5fdc\u306b\u591a\u7528\u3055\u308c\u3066\u3044\u307e\u3059\u3002<\/strong>\u3057\u304b\u3057\u3001\u30aa\u30ea\u30b4\uff08dT\uff09\u30d7\u30e9\u30a4\u30de\u30fc\u306f\u5e38\u306b\u8ee2\u5199\u7269\u306e3\u2032\u672b\u7aef\u304b\u3089\u9006\u8ee2\u5199\u3092\u958b\u59cb\u3059\u308b\u305f\u3081\u3001\u5f37\u56fa\u306a\u4e8c\u6b21\u69cb\u9020\u304c\u5b58\u5728\u3059\u308b\u3068\u4e0d\u5b8c\u5168\u306acDNA \u306e\u5408\u6210\u306b\u3064\u306a\u304c\u308b\u53ef\u80fd\u6027\u304c\u3042\u308a\u307e\u3059\u3002FFPE\u8a66\u6599\u304b\u3089\u5358\u96e2\u3055\u308c\u305fRNA\u306a\u3069\u306e\u3001\u30d5\u30e9\u30b0\u30e1\u30f3\u30c8\u5316\u3057\u305fRNA\u306e\u30aa\u30ea\u30b4\uff08dT\uff09\u30d7\u30e9\u30a4\u30df\u30f3\u30b0\u3082\u554f\u984c\u3092\u751f\u3058\u308b\u53ef\u80fd\u6027\u304c\u3042\u308a\u307e\u3059\u3002\u3057\u304b\u3057\u3001\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u30d7\u30e9\u30a4\u30de\u30fc\u304c\u30bf\u30fc\u30b2\u30c3\u30c8\u306e3\u2032\u672b\u7aef\u8fd1\u508d\u306b\u30c7\u30b6\u30a4\u30f3\u3055\u308c\u3066\u3044\u308b\u9650\u308a\u3001\u3053\u306e\u4f4d\u7f6e\u306e\u4e0b\u6d41\u306b\u304a\u3051\u308b\u65e9\u671f\u4f38\u9577\u505c\u6b62\u306f\u901a\u5e38\u91cd\u5927\u306a\u554f\u984c\u3068\u306f\u306a\u308a\u307e\u305b\u3093\u3002<\/p>\n<div id=\"attachment_2058\" style=\"width: 738px\" class=\"wp-caption aligncenter\"><a href=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/qpcr-basic44-fig.png\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-2058\" class=\"size-full wp-image-2058\" src=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/qpcr-basic44-fig.png\" alt=\"qpcr-basic44-fig\" width=\"728\" height=\"394\" \/><\/a><p id=\"caption-attachment-2058\" class=\"wp-caption-text\">\u56f3 \u4e00\u822c\u7684\u306b\u4f7f\u7528\u3055\u308c\u308bRNA\u30d7\u30e9\u30a4\u30df\u30f3\u30b0\u6cd5\u306e\u56f3\u89e3<\/p><\/div>\n<p><strong>\u5f0a\u793e\u3067\u306f\u3044\u304f\u3064\u304b\u306e\u7a2e\u985e\u306e\u30aa\u30ea\u30b4\uff08dT\uff09\u30d7\u30e9\u30a4\u30de\u30fc\u3092\u3054\u63d0\u4f9b\u3057\u3066\u3044\u307e\u3059\u3002<\/strong><a href=\"https:\/\/www.thermofisher.com\/order\/catalog\/product\/18418020?CID=gsd_pcr_sbu_r04_jp_cp0000_pjt0000_gsd00000_0so_blg_op_awa_oc_s00_qpcr50_Social_LAB\" target=\"_blank\" rel=\"noopener noreferrer\">Oligo\uff08dT\uff0920<\/a>\u306f\u3001\u30c1\u30df\u30b8\u30f320\u91cf\u4f53\u306e\u5747\u4e00\u6df7\u5408\u7269\u3067\u3042\u308a\u3001<a href=\"https:\/\/www.thermofisher.com\/order\/catalog\/product\/18418012?CID=gsd_pcr_sbu_r04_jp_cp0000_pjt0000_gsd00000_0so_blg_op_awa_oc_s00_qpcr50_Social_LAB\" target=\"_blank\" rel=\"noopener noreferrer\">Oligo\uff08dT\uff0912-18<\/a>\u306f\u3001\u30c1\u30df\u30b8\u30f312 \u91cf\u4f53\u3068\u30c1\u30df\u30b8\u30f318\u91cf\u4f53\u306e\u6df7\u5408\u7269\u3067\u3059\u3002<a href=\"https:\/\/www.thermofisher.com\/order\/catalog\/product\/12577011?CID=gsd_pcr_sbu_r04_jp_cp0000_pjt0000_gsd00000_0so_blg_op_awa_oc_s00_qpcr50_Social_LAB\" target=\"_blank\" rel=\"noopener noreferrer\">\u30a2\u30f3\u30ab\u30fc\u4ed8\u304d\u30aa\u30ea\u30b4\uff08dT\uff09\u30d7\u30e9\u30a4\u30de\u30fc<\/a>\u306f\u30013\u2032UTR\/poly\uff08A\uff09\u30b8\u30e3\u30f3\u30af\u30b7\u30e7\u30f3\u3067\u30a2\u30cb\u30fc\u30eb\u3059\u308b\u3053\u3068\u306b\u3088\u308a\u3001poly\uff08A\uff09\u30b9\u30ea\u30c3\u30d7\u3092\u56de\u907f\u3059\u308b\u3088\u3046\u306b\u30c7\u30b6\u30a4\u30f3\u3055\u308c\u3066\u3044\u307e\u3059\u3002\u71b1\u5b89\u5b9a\u6027\u306e\u9ad8\u3044RT\u3067\u306f\u3001\u77ed\u3044\u30d7\u30e9\u30a4\u30de\u30fc\u3068\u6bd4\u8f03\u3057\u3066\u9ad8\u6e29\u3067\u3088\u308a\u5805\u56fa\u306b\u30a2\u30cb\u30fc\u30eb\u3057\u305f\u72b6\u614b\u3092\u4fdd\u6301\u3059\u308b\u3001\u9577\u3044\u30d7\u30e9\u30a4\u30de\u30fc\u306e\u307b\u3046\u304c\u6027\u80fd\u304c\u9ad8\u304f\u306a\u308b\u53ef\u80fd\u6027\u3082\u3042\u308a\u307e\u3059\u3002\u6a19\u6e96\u5316\u306b18SrRNA\u3092\u4f7f\u7528\u3059\u308b\u5834\u5408\u306b\u306f\u3001\u30aa\u30ea\u30b4\uff08dT\uff09\u30d7\u30e9\u30a4\u30de\u30fc\u306f\u63a8\u5968\u3057\u307e\u305b\u3093\u3002<\/p>\n<p><strong>\u914d\u5217\u7279\u7570\u7684\u30d7\u30e9\u30a4\u30de\u30fc\u306f\u3001\u6700\u9ad8\u306e\u7279\u7570\u6027\u3092\u793a\u3057\u3001RT\u7528\u30d7\u30e9\u30a4\u30de\u30fc\u306e\u4e2d\u3067\u306f\u6700\u3082\u4e00\u8cab\u6027\u306e\u3042\u308b\u3053\u3068\u304c\u793a\u3055\u308c\u3066\u3044\u307e\u3059\u3002<\/strong>\u3057\u304b\u3057\u3001\u914d\u5217\u7279\u7570\u7684\u30d7\u30e9\u30a4\u30de\u30fc\u306f\u30aa\u30ea\u30b4\uff08dT\uff09\u30d7\u30e9\u30a4\u30de\u30fc\u3084\u30e9\u30f3\u30c0\u30e0\u30d7\u30e9\u30a4\u30de\u30fc\u306e\u3088\u3046\u306a\u67d4\u8edf\u6027\u3092\u5f97\u308b\u3053\u3068\u306f\u3067\u304d\u305a\u3001\u30bf\u30fc\u30b2\u30c3\u30c8\u907a\u4f1d\u5b50\u7523\u7269\u306ecDNA\u30b3\u30d4\u30fc\u306e\u307f\u304c\u5408\u6210\u3055\u308c\u307e\u3059\u3002\u3053\u306e\u305f\u3081\u914d\u5217\u7279\u7570\u7684\u30d7\u30e9\u30a4\u30de\u30fc\u306f\u3001\u5c11\u91cf\u307e\u305f\u306f\u8cb4\u91cd\u306a\u8a66\u6599\u3092\u53d6\u308a\u6271\u3046\u7814\u7a76\u306b\u304a\u3044\u3066\u306f\u4e00\u822c\u7684\u306b\u6700\u826f\u306e\u9078\u629e\u80a2\u3067\u306f\u3042\u308a\u307e\u305b\u3093\u30021-Step qRT-PCR\u53cd\u5fdc\u306b\u304a\u3044\u3066\u306fcDNA\u5408\u6210\u306b\u306f\u5e38\u306b\u914d\u5217\u7279\u7570\u7684\u30d7\u30e9\u30a4\u30de\u30fc\u3092\u4f7f\u7528\u3057\u307e\u3059\u304c\u30012-Step \u53cd\u5fdc\u306b\u304a\u3044\u3066\u306f\u4ed6\u306e\u30d7\u30e9\u30a4\u30de\u30fc\u3092\u7528\u3044\u307e\u3059\u3002<\/p>\n<p>\u5404\u30d7\u30e9\u30a4\u30de\u30fc\u306f\u305d\u308c\u305e\u308c\u7279\u5fb4\u7684\u306a\u7406\u8ad6\u7684\u9577\u6240\u3068\u6b20\u70b9\u3092\u6709\u3057\u3066\u3044\u307e\u3059\u3002\u3055\u3089\u306b\u5404\u30bf\u30fc\u30b2\u30c3\u30c8\u306f\u7570\u306a\u308b\u30d7\u30e9\u30a4\u30de\u30fc\u306b\u5bfe\u3057\u3066\u7570\u306a\u3063\u305f\u53cd\u5fdc\u3092\u793a\u3059\u53ef\u80fd\u6027\u304c\u3042\u308a\u307e\u3059\u3002\u7406\u60f3\u7684\u306b\u306f\u3001\u521d\u671f\u306e\u30a2\u30c3\u30bb\u30a4\u8a55\u4fa1\u6bb5\u968e\u306b\u304a\u3044\u3066\u5404\u30d7\u30e9\u30a4\u30de\u30fc\u3092\u8a55\u4fa1\u3057\u3001\u3069\u306e\u30d7\u30e9\u30a4\u30de\u30fc\u3067\u6700\u9069\u306a\u611f\u5ea6\u3068\u7cbe\u5ea6\u3092\u5f97\u3089\u308c\u308b\u304b\u3092\u6c7a\u5b9a\u3059\u308b\u3053\u3068\u304c\u5fc5\u8981\u3067\u3059\u3002<\/p>\n<h2>\u9006\u8ee2\u5199\u306e\u52b9\u7387\u306b\u5f71\u97ff\u3092\u4e0e\u3048\u308b\u56e0\u5b50<\/h2>\n<p><strong>\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u306b\u304a\u3044\u3066\u3001RT\u30b9\u30c6\u30fc\u30b8\u306fPCR\u30b9\u30c6\u30fc\u30b8\u3088\u308a\u3082\u4e00\u8cab\u6027\u304c\u4f4e\u304f\u306a\u3063\u3066\u3044\u307e\u3059\u3002<\/strong>\u3053\u308c\u306f\u3001\u30c6\u30f3\u30d7\u30ec\u30fc\u30c8RNA\u306b\u95a2\u9023\u3057\u305f\u8981\u56e0\u306e\u7d44\u307f\u5408\u308f\u305b\u306b\u3088\u308b\u3082\u306e\u3067\u3001\u71b1\u5b89\u5b9a\u6027DNA\u30dd\u30ea\u30e1\u30e9\u30fc\u30bc\u306b\u95a2\u3057\u3066\u306f\u901a\u5e38\u3053\u306e\u7d44\u307f\u5408\u308f\u305b\u306b\u3088\u308b\u8a66\u9a13\u306f\u884c\u308f\u308c\u3066\u3044\u307e\u305b\u3093\u3002\u3053\u308c\u3089\u306e\u8981\u56e0\u3068\u3057\u3066\u4ee5\u4e0b\u306e\u3082\u306e\u304c\u6319\u3052\u3089\u308c\u307e\u3059\u3002<\/p>\n<ul>\n<li><strong>RNA\u5206\u89e3\u5ea6\u306e\u76f8\u9055<\/strong>\uff1a\u7279\u5b9a\u306eRNA\u8a66\u6599\u306e\u5206\u89e3\u91cf\u306f\u3001cDNA\u306b\u5909\u63db\u3055\u308c\u3066\u5b9a\u91cf\u3055\u308c\u308bmRNA\u30bf\u30fc\u30b2\u30c3\u30c8\u306e\u5272\u5408\u306b\u76f4\u63a5\u5f71\u97ff\u3057\u307e\u3059\u3002\u4f7f\u7528\u3059\u308bRT\u30d7\u30e9\u30a4\u30de\u30fc\u306b\u3088\u3063\u3066\u306f\u3001\u5206\u89e3\u306e\u5f71\u97ff\u306b\u3088\u308a\u3001RT\u306b\u3088\u308b\u5b8c\u5168\u9577\u306e\u30bf\u30fc\u30b2\u30c3\u30c8\u30a2\u30f3\u30d7\u30ea\u30b3\u30f3\u306ecDNA\u306e\u751f\u6210\u304c\u963b\u5bb3\u3055\u308c\u308b\u53ef\u80fd\u6027\u304c\u3042\u308a\u307e\u3059\u3002RT\u52b9\u7387\u304c\u4f4e\u3044\u307b\u3069PCR\u30a2\u30c3\u30bb\u30a4\u306e\u611f\u5ea6\u306f\u4f4e\u304f\u306a\u308a\u307e\u3059\u3002\u6a19\u6e96\u5316\u3055\u308c\u3066\u3044\u306a\u3044\u52b9\u7387\u306e\u5909\u52d5\u306f\u4e0d\u6b63\u78ba\u306a\u7d50\u679c\u306b\u3064\u306a\u304c\u308b\u53ef\u80fd\u6027\u304c\u3042\u308a\u307e\u3059\u3002<\/li>\n<li><strong>GC\u542b\u91cf\u3001RNA\u8a66\u6599\u306e\u8907\u96d1\u6027\u304a\u3088\u3073\u4f7f\u7528\u3059\u308bRT\u9175\u7d20<\/strong>\uff1aRNA\u767a\u73fe\u91cf\u306e\u6bd4\u8f03\u306b\u304a\u3044\u3066\u306f\u3001RT\u304c\u8a66\u6599\u9593\u306e\u3055\u3051\u3089\u308c\u306a\u3044\u5dee\u306b\u611f\u53d7\u6027\u304c\u4f4e\u3044\u307b\u3069\u7cbe\u5ea6\u306f\u9ad8\u304f\u306a\u308a\u307e\u3059\u3002\u4f8b\u3048\u3070\u3001RT\u30d7\u30e9\u30a4\u30de\u30fc\u306b\u9069\u5408\u3057\u306a\u3044\u3059\u3079\u3066\u306e\u30d0\u30c3\u30af\u30b0\u30e9\u30a6\u30f3\u30c9\u306e\u6838\u9178\u306b\u3088\u308b\u8a66\u6599\u306e\u8907\u96d1\u6027\u3060\u3051\u3067\u3082\u300110\u500d\u306b\u304a\u3088\u3076\u53cd\u5fdc\u52b9\u7387\u306e\u5dee\u3092\u3082\u305f\u3089\u3057\u5f97\u308b\u3053\u3068\u304c\u30c7\u30fc\u30bf\u306b\u3088\u3063\u3066\u793a\u3055\u308c\u3066\u3044\u307e\u3059\u3002\u3053\u306e\u3088\u3046\u306a\u30d0\u30c3\u30af\u30b0\u30e9\u30a6\u30f3\u30c9\u306b\u304a\u3044\u3066\u3082\u4e00\u8cab\u3057\u305fcDNA\u5408\u6210\u304c\u53ef\u80fd\u306aRT\u304c\u7406\u60f3\u7684\u3067\u3059\u3002<\/li>\n<li><strong>\u6709\u6a5f\u6eb6\u5a92\u304a\u3088\u3073\u30ab\u30aa\u30c8\u30ed\u30d4\u30c3\u30af\u5869\u306e\u6b8b\u5b58<\/strong>\uff1a\u30a8\u30bf\u30ce\u30fc\u30eb\u304a\u3088\u3073\u30b0\u30a2\u30cb\u30b8\u30f3\u306fRNA\u3092\u52b9\u7387\u7684\u306b\u62bd\u51fa\u3059\u308b\u305f\u3081\u306b\u5fc5\u8981\u3067\u3059\u304c\u3001\u9175\u7d20\u53cd\u5fdc\u3092\u5f37\u304f\u963b\u5bb3\u3057\u307e\u3059\u3002RNA\u8a66\u6599\u9593\u306b\u304a\u3051\u308b\u3053\u308c\u3089\u306e\u6c5a\u67d3\u7269\u8cea\u306e\u91cf\u306e\u5dee\u306f\u3001\u8a66\u6599\u9593\u306e\u6bd4\u8f03\u306b\u5f71\u97ff\u3092\u4e0e\u3048\u308b\u53ef\u80fd\u6027\u304c\u3042\u308a\u307e\u3059\u3002\u3053\u306e\u305f\u3081\u3001\u3053\u308c\u3089\u306e\u593e\u96d1\u7269\u306e\u91cf\u304c\u4e00\u8cab\u3057\u3066\u4f4e\u304f\u306a\u308b\u3088\u3046\u306aRNA\u7cbe\u88fd\u65b9\u6cd5\u3092\u4f7f\u7528\u3059\u308b\u3053\u3068\u304c\u91cd\u8981\u3067\u3059\u3002\u5f0a\u793e\u3067\u306f\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u53cd\u5fdc\u306b\u304a\u3044\u3066\u3001\u691c\u8a3c\u6e08\u307f\u306e\u30ce\u30fc\u30de\u30e9\u30a4\u30b6\u30fc\u907a\u4f1d\u5b50\u3092\u4f7f\u7528\u3059\u308b\u3053\u3068\u3082\u63a8\u5968\u3057\u3066\u3044\u307e\u3059\u3002<\/li>\n<\/ul>\n<h2><\/h2>\n<h2>\u3010\u7121\u6599\u516c\u958b\u4e2d\u3011\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u30cf\u30f3\u30c9\u30d6\u30c3\u30af<\/h2>\n<p>\u3053\u306e\u30cf\u30f3\u30c9\u30d6\u30c3\u30af\u3067\u306f\u3001\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u306e\u7406\u8ad6\u3084\u5b9f\u9a13\u30c7\u30b6\u30a4\u30f3\u306e\u8a2d\u8a08\u306a\u3069\u3001\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u306e\u57fa\u790e\u77e5\u8b58\u304c\u63b2\u8f09\u3055\u308c\u3066\u3044\u307e\u3059\u3002\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u3092\u59cb\u3081\u305f\u3070\u304b\u308a\u306e\u65b9\u3084\u3053\u308c\u304b\u3089\u5b9f\u9a13\u3092\u8003\u3048\u3066\u3044\u308b\u65b9\u306b\u3046\u3063\u3066\u3064\u3051\u306e\u30cf\u30f3\u30c9\u30d6\u30c3\u30af\u3067\u3059\u3002PDF\u30d5\u30a1\u30a4\u30eb\u306e\u30c0\u30a6\u30f3\u30ed\u30fc\u30c9\u3092\u3054\u5e0c\u671b\u306e\u65b9\u306f\u3001\u4e0b\u8a18\u30dc\u30bf\u30f3\u3088\u308a\u304a\u7533\u3057\u8fbc\u307f\u304f\u3060\u3055\u3044\u3002<\/p>\n<p><a class=\"btn btn-red\" href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/global\/forms\/real-time-pcr-handbook-form.html?CID=gsd_pcr_sbu_r04_jp_cp0000_pjt0000_gsd00000_0so_blg_op_awa_oc_s00_qpcr50_Social_LAB\" target=\"_blank\" rel=\"noopener\">\u30c0\u30a6\u30f3\u30ed\u30fc\u30c9\u3059\u308b<\/a><\/p>\n<h2>\u3010\u7121\u6599\u516c\u958b\u4e2d\u3011\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u30c8\u30e9\u30d6\u30eb\u30b7\u30e5\u30fc\u30c6\u30a3\u30f3\u30b0<\/h2>\n<p>\u7570\u5e38\u306aS\u5b57\u72b6\u306e\u5897\u5e45\u66f2\u7dda\u3001NTC\u3067\u306e\u5897\u5e45\u691c\u51fa\u3001\u5897\u5e45\u304c\u898b\u3089\u308c\u306a\u3044\u306a\u3069\u3001\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u306e\u5b9f\u9a13\u4e2d\u306b\u56f0\u3063\u305f\u969b\u306e\u624b\u52a9\u3051\u306b\u306a\u308b\u60c5\u5831\u3092\u7d39\u4ecb\u3057\u3066\u3044\u307e\u3059\u3002PDF\u30d5\u30a1\u30a4\u30eb\u306e\u30c0\u30a6\u30f3\u30ed\u30fc\u30c9\u3092\u3054\u5e0c\u671b\u306e\u65b9\u306f\u3001\u4e0b\u8a18\u30dc\u30bf\u30f3\u3088\u308a\u304a\u7533\u3057\u8fbc\u307f\u304f\u3060\u3055\u3044\u3002<\/p>\n<p><a class=\"btn btn-red\" href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/global\/forms\/pcr-system-troubleshooting.html?CID=gsd_pcr_sbu_r04_jp_cp0000_pjt0000_gsd00000_0so_blg_op_awa_oc_s00_qpcr50_Social_LAB\" target=\"_blank\" rel=\"noopener\">\u30c0\u30a6\u30f3\u30ed\u30fc\u30c9\u3059\u308b<\/a><\/p>\n<p>&nbsp;<\/p>\n<p>\u7814\u7a76\u7528\u306b\u306e\u307f\u4f7f\u7528\u3067\u304d\u307e\u3059\u3002\u8a3a\u65ad\u7528\u306b\u306f\u4f7f\u7528\u3044\u305f\u3060\u3051\u307e\u305b\u3093\u3002<\/p>\n","protected":false},"excerpt":{"rendered":"<p>\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u306e\u9006\u8ee2\u5199\u53cd\u5fdc\u306b\u304a\u3051\u308b\u9006\u8ee2\u5199\u9175\u7d20\u3084\u30d7\u30e9\u30a4\u30de\u30fc\u306f\u3069\u306e\u3088\u3046\u306b\u9078\u3079\u3070\u826f\u3044\u3067\u3057\u3087\u3046\u304b\uff1f\u4eca\u56de\u306f\u30011-Step qRT-PCR\u30682-Step qRT-PCR\u306e\u5229\u70b9\u3068\u6b20\u70b9\u3084\u3001\u30d7\u30e9\u30a4\u30de\u30fc\u306e\u9078\u629e\u306a\u3069\u3001\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u306e\u9006\u8ee2\u5199\u53cd\u5fdc\u306b\u304a\u3044\u3066\u6c17\u3092\u3064\u3051\u308b\u3079\u304d\u30dd\u30a4\u30f3\u30c8\u3092\u3054\u7d39\u4ecb\u3057\u307e\u3059\u3002<\/p>\n","protected":false},"author":988,"featured_media":3498,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_monsterinsights_skip_tracking":false,"_genesis_hide_title":false,"_genesis_hide_breadcrumbs":false,"_genesis_hide_singular_image":false,"_genesis_hide_footer_widgets":false,"_genesis_custom_body_class":"","_genesis_custom_post_class":"","_genesis_layout":"","_jetpack_newsletter_access":"","_jetpack_dont_email_post_to_subs":false,"_jetpack_newsletter_tier_id":0,"_jetpack_memberships_contains_paywalled_content":false,"_jetpack_hide_featured_image":false,"_jetpack_featured_image_duplicate_dismissed":0,"_jetpack_feature_clip_id":0,"_jetpack_memberships_contains_paid_content":false,"footnotes":"","jetpack_post_was_ever_published":false},"categories":[156],"tags":[7],"division":[],"class_list":["post-777","post","type-post","status-publish","format-standard","has-post-thumbnail","category-mol-bio","tag-qpcr","entry"],"_selected_authors":"","_selected_reviewers":"","acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v28.9 (Yoast SEO v28.9) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>1-Step qRT-PCR\u30682-Step qRT-PCR\u306e\u5229\u70b9\u3068\u6b20\u70b9\u3068\u306f\uff1f \u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u306e\u9006\u8ee2\u5199\u53cd\u5fdc\u306b\u304a\u3044\u3066\u6c17\u3092\u3064\u3051\u308b\u3079\u304d\u30dd\u30a4\u30f3\u30c8 - Learning at the Bench<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/qpcr-basic44\/\" \/>\n<meta property=\"og:locale\" content=\"ja_JP\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"1-Step qRT-PCR\u30682-Step qRT-PCR\u306e\u5229\u70b9\u3068\u6b20\u70b9\u3068\u306f\uff1f \u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u306e\u9006\u8ee2\u5199\u53cd\u5fdc\u306b\u304a\u3044\u3066\u6c17\u3092\u3064\u3051\u308b\u3079\u304d\u30dd\u30a4\u30f3\u30c8\" \/>\n<meta property=\"og:description\" content=\"\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u306e\u9006\u8ee2\u5199\u53cd\u5fdc\u306b\u304a\u3051\u308b\u9006\u8ee2\u5199\u9175\u7d20\u3084\u30d7\u30e9\u30a4\u30de\u30fc\u306f\u3069\u306e\u3088\u3046\u306b\u9078\u3079\u3070\u826f\u3044\u3067\u3057\u3087\u3046\u304b\uff1f\u4eca\u56de\u306f\u30011-Step qRT-PCR\u30682-Step qRT-PCR\u306e\u5229\u70b9\u3068\u6b20\u70b9\u3084\u3001\u30d7\u30e9\u30a4\u30de\u30fc\u306e\u9078\u629e\u306a\u3069\u3001\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u306e\u9006\u8ee2\u5199\u53cd\u5fdc\u306b\u304a\u3044\u3066\u6c17\u3092\u3064\u3051\u308b\u3079\u304d\u30dd\u30a4\u30f3\u30c8\u3092\u3054\u7d39\u4ecb\u3057\u307e\u3059\u3002\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/qpcr-basic44\/\" \/>\n<meta property=\"og:site_name\" content=\"Learning at the Bench\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/ThermoFisherJapan\" \/>\n<meta property=\"article:published_time\" content=\"2017-04-11T00:00:00+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2025-04-16T06:22:09+00:00\" \/>\n<meta property=\"og:image\" content=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/qpcr-basic44-title.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"1200\" \/>\n\t<meta property=\"og:image:height\" content=\"628\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"LATB Staff\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:creator\" content=\"@ThermoFisherJP\" \/>\n<meta name=\"twitter:site\" content=\"@ThermoFisherJP\" \/>\n<meta name=\"twitter:label1\" content=\"\u57f7\u7b46\u8005\" \/>\n\t<meta name=\"twitter:data1\" content=\"LATB Staff\" \/>\n\t<meta name=\"twitter:label2\" content=\"\u63a8\u5b9a\u8aad\u307f\u53d6\u308a\u6642\u9593\" \/>\n\t<meta name=\"twitter:data2\" content=\"13\u5206\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/qpcr-basic44\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/qpcr-basic44\\\/\"},\"author\":{\"name\":\"LATB Staff\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#\\\/schema\\\/person\\\/201e6a5abb838fa34e8ff0174b015d36\"},\"headline\":\"1-Step qRT-PCR\u30682-Step qRT-PCR\u306e\u5229\u70b9\u3068\u6b20\u70b9\u3068\u306f\uff1f \u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u306e\u9006\u8ee2\u5199\u53cd\u5fdc\u306b\u304a\u3044\u3066\u6c17\u3092\u3064\u3051\u308b\u3079\u304d\u30dd\u30a4\u30f3\u30c8\",\"datePublished\":\"2017-04-11T00:00:00+00:00\",\"dateModified\":\"2025-04-16T06:22:09+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/qpcr-basic44\\\/\"},\"wordCount\":191,\"commentCount\":0,\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/qpcr-basic44\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2019\\\/07\\\/qpcr-basic44-title.jpg\",\"keywords\":[\"\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\"],\"articleSection\":[\"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023\"],\"inLanguage\":\"ja\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/qpcr-basic44\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/qpcr-basic44\\\/\",\"url\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/qpcr-basic44\\\/\",\"name\":\"1-Step qRT-PCR\u30682-Step qRT-PCR\u306e\u5229\u70b9\u3068\u6b20\u70b9\u3068\u306f\uff1f \u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u306e\u9006\u8ee2\u5199\u53cd\u5fdc\u306b\u304a\u3044\u3066\u6c17\u3092\u3064\u3051\u308b\u3079\u304d\u30dd\u30a4\u30f3\u30c8 - Learning at the Bench\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/qpcr-basic44\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/qpcr-basic44\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2019\\\/07\\\/qpcr-basic44-title.jpg\",\"datePublished\":\"2017-04-11T00:00:00+00:00\",\"dateModified\":\"2025-04-16T06:22:09+00:00\",\"author\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#\\\/schema\\\/person\\\/201e6a5abb838fa34e8ff0174b015d36\"},\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/qpcr-basic44\\\/#breadcrumb\"},\"inLanguage\":\"ja\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/qpcr-basic44\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"ja\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/qpcr-basic44\\\/#primaryimage\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2019\\\/07\\\/qpcr-basic44-title.jpg\",\"contentUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2019\\\/07\\\/qpcr-basic44-title.jpg\",\"width\":1200,\"height\":628,\"caption\":\"qpcr-basic44-title\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/qpcr-basic44\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"1-Step qRT-PCR\u30682-Step qRT-PCR\u306e\u5229\u70b9\u3068\u6b20\u70b9\u3068\u306f\uff1f \u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u306e\u9006\u8ee2\u5199\u53cd\u5fdc\u306b\u304a\u3044\u3066\u6c17\u3092\u3064\u3051\u308b\u3079\u304d\u30dd\u30a4\u30f3\u30c8\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#website\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/\",\"name\":\"Learning at the Bench\",\"description\":\"\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"ja\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#\\\/schema\\\/person\\\/201e6a5abb838fa34e8ff0174b015d36\",\"name\":\"LATB Staff\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"ja\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/8803277856c8b753feb4217dff0f9953327452df1a615c3c88b2f9864efb2ddd?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/8803277856c8b753feb4217dff0f9953327452df1a615c3c88b2f9864efb2ddd?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/8803277856c8b753feb4217dff0f9953327452df1a615c3c88b2f9864efb2ddd?s=96&d=mm&r=g\",\"caption\":\"LATB Staff\"},\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/author\\\/latbstaff\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"1-Step qRT-PCR\u30682-Step qRT-PCR\u306e\u5229\u70b9\u3068\u6b20\u70b9\u3068\u306f\uff1f \u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u306e\u9006\u8ee2\u5199\u53cd\u5fdc\u306b\u304a\u3044\u3066\u6c17\u3092\u3064\u3051\u308b\u3079\u304d\u30dd\u30a4\u30f3\u30c8 - Learning at the Bench","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/qpcr-basic44\/","og_locale":"ja_JP","og_type":"article","og_title":"1-Step qRT-PCR\u30682-Step qRT-PCR\u306e\u5229\u70b9\u3068\u6b20\u70b9\u3068\u306f\uff1f \u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u306e\u9006\u8ee2\u5199\u53cd\u5fdc\u306b\u304a\u3044\u3066\u6c17\u3092\u3064\u3051\u308b\u3079\u304d\u30dd\u30a4\u30f3\u30c8","og_description":"\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u306e\u9006\u8ee2\u5199\u53cd\u5fdc\u306b\u304a\u3051\u308b\u9006\u8ee2\u5199\u9175\u7d20\u3084\u30d7\u30e9\u30a4\u30de\u30fc\u306f\u3069\u306e\u3088\u3046\u306b\u9078\u3079\u3070\u826f\u3044\u3067\u3057\u3087\u3046\u304b\uff1f\u4eca\u56de\u306f\u30011-Step qRT-PCR\u30682-Step qRT-PCR\u306e\u5229\u70b9\u3068\u6b20\u70b9\u3084\u3001\u30d7\u30e9\u30a4\u30de\u30fc\u306e\u9078\u629e\u306a\u3069\u3001\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u306e\u9006\u8ee2\u5199\u53cd\u5fdc\u306b\u304a\u3044\u3066\u6c17\u3092\u3064\u3051\u308b\u3079\u304d\u30dd\u30a4\u30f3\u30c8\u3092\u3054\u7d39\u4ecb\u3057\u307e\u3059\u3002","og_url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/qpcr-basic44\/","og_site_name":"Learning at the Bench","article_publisher":"https:\/\/www.facebook.com\/ThermoFisherJapan","article_published_time":"2017-04-11T00:00:00+00:00","article_modified_time":"2025-04-16T06:22:09+00:00","og_image":[{"width":1200,"height":628,"url":"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/qpcr-basic44-title.jpg","type":"image\/jpeg"}],"author":"LATB Staff","twitter_card":"summary_large_image","twitter_creator":"@ThermoFisherJP","twitter_site":"@ThermoFisherJP","twitter_misc":{"\u57f7\u7b46\u8005":"LATB Staff","\u63a8\u5b9a\u8aad\u307f\u53d6\u308a\u6642\u9593":"13\u5206"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/qpcr-basic44\/#article","isPartOf":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/qpcr-basic44\/"},"author":{"name":"LATB Staff","@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#\/schema\/person\/201e6a5abb838fa34e8ff0174b015d36"},"headline":"1-Step qRT-PCR\u30682-Step qRT-PCR\u306e\u5229\u70b9\u3068\u6b20\u70b9\u3068\u306f\uff1f \u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u306e\u9006\u8ee2\u5199\u53cd\u5fdc\u306b\u304a\u3044\u3066\u6c17\u3092\u3064\u3051\u308b\u3079\u304d\u30dd\u30a4\u30f3\u30c8","datePublished":"2017-04-11T00:00:00+00:00","dateModified":"2025-04-16T06:22:09+00:00","mainEntityOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/qpcr-basic44\/"},"wordCount":191,"commentCount":0,"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/qpcr-basic44\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/qpcr-basic44-title.jpg","keywords":["\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR"],"articleSection":["\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023"],"inLanguage":"ja","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/qpcr-basic44\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/qpcr-basic44\/","url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/qpcr-basic44\/","name":"1-Step qRT-PCR\u30682-Step qRT-PCR\u306e\u5229\u70b9\u3068\u6b20\u70b9\u3068\u306f\uff1f \u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u306e\u9006\u8ee2\u5199\u53cd\u5fdc\u306b\u304a\u3044\u3066\u6c17\u3092\u3064\u3051\u308b\u3079\u304d\u30dd\u30a4\u30f3\u30c8 - Learning at the Bench","isPartOf":{"@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/qpcr-basic44\/#primaryimage"},"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/qpcr-basic44\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/qpcr-basic44-title.jpg","datePublished":"2017-04-11T00:00:00+00:00","dateModified":"2025-04-16T06:22:09+00:00","author":{"@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#\/schema\/person\/201e6a5abb838fa34e8ff0174b015d36"},"breadcrumb":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/qpcr-basic44\/#breadcrumb"},"inLanguage":"ja","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/qpcr-basic44\/"]}]},{"@type":"ImageObject","inLanguage":"ja","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/qpcr-basic44\/#primaryimage","url":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/qpcr-basic44-title.jpg","contentUrl":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/qpcr-basic44-title.jpg","width":1200,"height":628,"caption":"qpcr-basic44-title"},{"@type":"BreadcrumbList","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/qpcr-basic44\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/"},{"@type":"ListItem","position":2,"name":"1-Step qRT-PCR\u30682-Step qRT-PCR\u306e\u5229\u70b9\u3068\u6b20\u70b9\u3068\u306f\uff1f \u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u306e\u9006\u8ee2\u5199\u53cd\u5fdc\u306b\u304a\u3044\u3066\u6c17\u3092\u3064\u3051\u308b\u3079\u304d\u30dd\u30a4\u30f3\u30c8"}]},{"@type":"WebSite","@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#website","url":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/","name":"Learning at the Bench","description":"","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"ja"},{"@type":"Person","@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#\/schema\/person\/201e6a5abb838fa34e8ff0174b015d36","name":"LATB Staff","image":{"@type":"ImageObject","inLanguage":"ja","@id":"https:\/\/secure.gravatar.com\/avatar\/8803277856c8b753feb4217dff0f9953327452df1a615c3c88b2f9864efb2ddd?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/8803277856c8b753feb4217dff0f9953327452df1a615c3c88b2f9864efb2ddd?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/8803277856c8b753feb4217dff0f9953327452df1a615c3c88b2f9864efb2ddd?s=96&d=mm&r=g","caption":"LATB Staff"},"url":"https:\/\/admin.acceleratingscience.com\/author\/latbstaff\/"}]}},"taxonomy_info":{"category":[{"value":156,"label":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023"}],"post_tag":[{"value":7,"label":"\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR"}]},"featured_image_src_large":["https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/qpcr-basic44-title-1024x536.jpg",760,398,true],"author_info":{"display_name":"LATB Staff","author_link":"https:\/\/admin.acceleratingscience.com\/author\/latbstaff\/"},"comment_info":0,"category_info":[{"term_id":156,"name":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","slug":"mol-bio","term_group":0,"term_taxonomy_id":156,"taxonomy":"category","description":"","parent":0,"count":540,"filter":"raw","meta":[],"cat_ID":156,"category_count":540,"category_description":"","cat_name":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","category_nicename":"mol-bio","category_parent":0}],"tag_info":[{"term_id":7,"name":"\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR","slug":"qpcr","term_group":0,"term_taxonomy_id":7,"taxonomy":"post_tag","description":"","parent":0,"count":91,"filter":"raw","meta":[]}],"jetpack-related-posts":[{"id":25247,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/exosome-gene-expression-ts-r-25018\/","url_meta":{"origin":777,"position":0},"title":"\u3010\u7b2c4\u56de\u3011&#8221;RNA cargo&#8221;\u306e\u7cbe\u88fd\u3068\u5b9a\u91cf\u89e3\u6790\uff5emiRNA\u306e\u5b9a\u91cf\u89e3\u6790\uff5e","author":"LatB Staff","date":"2026\u5e745\u670829\u65e5","format":false,"excerpt":"\u524d\u56de\uff08\u3010\u7b2c3\u56de\u3011\u201cRNA cargo\u201d\u306e\u7cbe\u88fd\u3068\u5b9a\u91cf\u89e3\u6790\uff09\u3067\u306f\u3001\u30a8\u30af\u30bd\u30bd\u30fc\u30e0 \uff08\u30a8\u30ad\u30bd\u30bd\u30fc\u30e0\uff09 \u304b\u3089\u306e\u2026","rel":"","context":"\u5206\u6790\u30fb\u6e2c\u5b9a\u95a2\u9023","block_context":{"text":"\u5206\u6790\u30fb\u6e2c\u5b9a\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/analysis\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25018_eyecatch-1.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25018_eyecatch-1.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25018_eyecatch-1.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25018_eyecatch-1.jpg?resize=700%2C400&ssl=1 2x"},"classes":[]},{"id":25325,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/exosome-gene-expression-ts-r-25019\/","url_meta":{"origin":777,"position":1},"title":"\u3010\u7b2c5\u56de\u3011 &#8220;RNA cargo&#8221;\u306e\u7cbe\u88fd\u3068\u5b9a\u91cf\u89e3\u6790\u300d\uff5emRNA\u306e\u5b9a\u91cf\u89e3\u6790\uff5e","author":"LatB Staff","date":"2026\u5e746\u670811\u65e5","format":false,"excerpt":"\u4eca\u56de\u306f\u3001\u30a8\u30af\u30bd\u30bd\u30fc\u30e0\uff08\u30a8\u30ad\u30bd\u30bd\u30fc\u30e0\uff09\u4e2d\u306emRNA\u306e\u5b9a\u91cf\u89e3\u6790\u306b\u3064\u3044\u3066\u8aac\u660e\u3057\u307e\u3059\u3002\u7b2c3\u56de\u3067\u30a8\u30af\u30bd\u30bd\u30fc\u30e0\u304b\u2026","rel":"","context":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","block_context":{"text":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/mol-bio\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25018_eyecatch-1.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25018_eyecatch-1.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25018_eyecatch-1.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25018_eyecatch-1.jpg?resize=700%2C400&ssl=1 2x"},"classes":[]},{"id":25565,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/exosome-antibody-ts-r-25068\/","url_meta":{"origin":777,"position":2},"title":"\u3010\u7b2c8\u56de\u3011\u30a8\u30af\u30bd\u30bd\u30fc\u30e0\u30b5\u30d6\u30bf\u30a4\u30d7\u306e\u5206\u753b\u6cd5 \uff1a \u30a6\u30a7\u30b9\u30bf\u30f3\u30d6\u30ed\u30c3\u30c8\uff0fqRT-PCR\uff0f\u30b7\u30fc\u30b1\u30f3\u30b9\u89e3\u6790\u306b\u9069\u3057\u305f\u5206\u753b\u65b9\u6cd5","author":"LatB Staff","date":"2026\u5e749\u670829\u65e5","format":false,"excerpt":"\u672c\u7a3f\u3067\u306f\u3001\u30a8\u30af\u30bd\u30bd\u30fc\u30e0\u819c\u4e0a\u306e\u7279\u5b9a\u306e\u30bf\u30f3\u30d1\u30af\u8cea\u3092\u6a19\u7684\u3068\u3057\u305f\u514d\u75ab\u5438\u7740\u6cd5\u306b\u57fa\u3065\u304f\u5206\u753b\u624b\u6cd5\u3092\u7d39\u4ecb\u3057\u307e\u3059\u3002\u30a8\u30af\u2026","rel":"","context":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","block_context":{"text":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/mol-bio\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25019_eyecatch.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25019_eyecatch.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25019_eyecatch.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25019_eyecatch.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25019_eyecatch.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25019_eyecatch.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":24545,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/digital-pcr-gene-expression-gsd-ts-sd-25082\/","url_meta":{"origin":777,"position":3},"title":"\u3010Absolute Q\u30c7\u30b8\u30bf\u30ebPCR\u30b7\u30b9\u30c6\u30e0\u306e\u6d3b\u7528\u4f8b\u3011\u30df\u30c8\u30b3\u30f3\u30c9\u30ea\u30a2DNA\u306e\u5b9a\u91cf","author":"LatB Staff","date":"2026\u5e741\u670816\u65e5","format":false,"excerpt":"Applied Biosystems\u2122 QuantStudio\u2122 Absolute Q\u2122 \u30c7\u30b8\u30bf\u30ebP\u2026","rel":"","context":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","block_context":{"text":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/mol-bio\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/12\/digital-pcr-gene-expression-gsd-ts-sd-25082_eyecatch.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/12\/digital-pcr-gene-expression-gsd-ts-sd-25082_eyecatch.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/12\/digital-pcr-gene-expression-gsd-ts-sd-25082_eyecatch.jpg?resize=525%2C300&ssl=1 1.5x"},"classes":[]},{"id":25472,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/exosome-ts-r-25067\/","url_meta":{"origin":777,"position":4},"title":"\u3010\u7b2c7\u56de\u3011 \u30a8\u30af\u30bd\u30bd\u30fc\u30e0\u30b5\u30d6\u30bf\u30a4\u30d7\u306e\u5206\u753b\u306e\u6982\u8981","author":"LatB Staff","date":"2026\u5e748\u670813\u65e5","format":false,"excerpt":"\u7d30\u80de\u304c\u5206\u6ccc\u3059\u308b\u7d30\u80de\u5916\u5c0f\u80de\u306e\u4e2d\u3067\u3082\u3001\u30a8\u30af\u30bd\u30bd\u30fc\u30e0\u306f\u305d\u306e\u60c5\u5831\u4f1d\u9054\u6a5f\u80fd\u3084\u75be\u60a3\u3068\u306e\u95a2\u9023\u6027\u304b\u3089\u6ce8\u76ee\u3092\u96c6\u3081\u3066\u3044\u307e\u2026","rel":"","context":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","block_context":{"text":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/mol-bio\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25019_eyecatch.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25019_eyecatch.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25019_eyecatch.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25019_eyecatch.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25019_eyecatch.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25019_eyecatch.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":24187,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/ngs-gene-expression-csd-ts-ion-25073\/","url_meta":{"origin":777,"position":5},"title":"\u3010\u3084\u3063\u3066\u307f\u305f\u3011\u5fae\u91cf\u30fb\u5206\u89e3RNA\u306b\u3088\u308b\u767a\u73fe\u89e3\u6790\u306e\u6700\u9069\u89e3\u306f\uff1fRNA-Seq\u3068Ion AmpliSeq Transcriptome\u3092\u6bd4\u3079\u3066\u307f\u305f","author":"LatB Staff","date":"2025\u5e7411\u670828\u65e5","format":false,"excerpt":"\u6b21\u4e16\u4ee3\u30b7\u30fc\u30b1\u30f3\u30b5\u3067\u306e\u767a\u73fe\u89e3\u6790\u306b\u53d6\u308a\u7d44\u3080\u969b\u3001RNA\u30b5\u30f3\u30d7\u30eb\u304c\u300c\u5c11\u306a\u3059\u304e\u308b\u300d\u300c\u5206\u89e3\u3057\u3066\u3044\u308b\u300d\u3068\u3044\u3046\u72b6\u6cc1\u306f\u2026","rel":"","context":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","block_context":{"text":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/mol-bio\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/11\/ngs-gene-expression-csd-ts-ion-25073_eyecatch-scaled.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/11\/ngs-gene-expression-csd-ts-ion-25073_eyecatch-scaled.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/11\/ngs-gene-expression-csd-ts-ion-25073_eyecatch-scaled.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/11\/ngs-gene-expression-csd-ts-ion-25073_eyecatch-scaled.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/11\/ngs-gene-expression-csd-ts-ion-25073_eyecatch-scaled.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/11\/ngs-gene-expression-csd-ts-ion-25073_eyecatch-scaled.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]}],"jetpack_sharing_enabled":true,"amp_enabled":true,"jetpack_featured_media_url":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/qpcr-basic44-title.jpg","_links":{"self":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/posts\/777","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/users\/988"}],"replies":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/comments?post=777"}],"version-history":[{"count":0,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/posts\/777\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/media\/3498"}],"wp:attachment":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/media?parent=777"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/categories?post=777"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/tags?post=777"},{"taxonomy":"division","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/division?post=777"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}