{"id":7841,"date":"2020-10-08T13:44:38","date_gmt":"2020-10-08T04:44:38","guid":{"rendered":"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/?p=7841"},"modified":"2025-02-10T14:31:33","modified_gmt":"2025-02-10T05:31:33","slug":"gene-editing_bid_ts_1","status":"publish","type":"post","link":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/gene-editing_bid_ts_1\/","title":{"rendered":"\u305d\u3046\u3044\u3046\u3053\u3068\u3060\u3063\u305f\u306e\u304b ! \u30b2\u30ce\u30e0\u7de8\u96c6\u5b9f\u9a13\uff08CRISPR\/Cas9\uff09 \uff5e\u7b2c1\u56de\u3000CRISPR\/Cas9\u30b7\u30b9\u30c6\u30e0\u306e\u539f\u7406\uff5e"},"content":{"rendered":"<h2>\u306f\u3058\u3081\u306b<\/h2>\n<p>A\u3055\u3093\u306f\u3053\u308c\u304b\u3089\u30b2\u30ce\u30e0\u7de8\u96c6\u3092\u5229\u7528\u3057\u3066\u907a\u4f1d\u5b50\u3092\u89e3\u6790\u3057\u305f\u3044\u3068\u8003\u3048\u3066\u3044\u307e\u3059\u3002\u3088\u304f\u8033\u306b\u3059\u308bCRISPR\/Cas9\u3067\u5b9f\u65bd\u3057\u305f\u3044\u306e\u3067\u3059\u304c\u3001\u4f55\u304b\u3089\u624b\u3092\u3064\u3051\u3066\u3044\u3044\u306e\u304b\u308f\u304b\u308a\u307e\u305b\u3093\u3002CRISPR\u3068\u306f\uff1fCas9\u30cc\u30af\u30ec\u30a2\u30fc\u30bc\u3068\u306f\uff1f\u7591\u554f\u3070\u304b\u308a\u306a\u306e\u3067\u30b2\u30ce\u30e0\u7de8\u96c6\u3084CRISPR\/Cas9\u30b7\u30b9\u30c6\u30e0\u306b\u8a73\u3057\u3044\u5148\u8f29\u306b\u6559\u3048\u3066\u3082\u3089\u3046\u3053\u3068\u306b\u306a\u308a\u307e\u3057\u305f\u3002<img loading=\"lazy\" decoding=\"async\" class=\"aligncenter wp-image-13986\" src=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/04\/gene-editing_bid_ts_3-01.png\" alt=\"\" width=\"500\" height=\"267\" srcset=\"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/04\/gene-editing_bid_ts_3-01.png 1787w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/04\/gene-editing_bid_ts_3-01-300x160.png 300w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/04\/gene-editing_bid_ts_3-01-1024x546.png 1024w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/04\/gene-editing_bid_ts_3-01-768x410.png 768w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/04\/gene-editing_bid_ts_3-01-1536x819.png 1536w\" sizes=\"auto, (max-width: 500px) 100vw, 500px\" \/><\/p>\n<h2>CRISPR\/Cas9\u30b7\u30b9\u30c6\u30e0\u3068\u306f<\/h2>\n<p><span style=\"color: #3366ff\">A\u3055\u3093<\/span>\uff1a<br \/>\n\u5148\u8f29\u3001CRISPR\/Cas9\u3092\u4f7f\u3063\u3066\u30b2\u30ce\u30e0\u7de8\u96c6\u5b9f\u9a13\u3092\u884c\u3044\u305f\u3044\u3093\u3067\u3059\u3002\u4f55\u304b\u3089\u59cb\u3081\u308c\u3070\u3044\u3044\u3067\u3059\u304b\uff1f<\/p>\n<p><span style=\"color: #ff00ff\">\u5148\u8f29<\/span>\uff1a<br \/>\n\u3058\u3083\u3042\u3001\u307e\u305a\u306f\u5b9f\u9a13\u524d\u306bCRISPR\/Cas9\u30b7\u30b9\u30c6\u30e0\u3092\u7406\u89e3\u3057\u3066\u304a\u3053\u3046\u304b\u3002\u305d\u306e\u65b9\u304c\u9078\u629e\u80a2\u3082\u5e83\u304c\u308b\u3088\u3002<\/p>\n<p><span style=\"color: #3366ff\">A\u3055\u3093<\/span>\uff1a<br \/>\n\u3088\u308d\u3057\u304f\u304a\u9858\u3044\u3057\u307e\u3059\uff01<\/p>\n<p><span style=\"color: #ff00ff\">\u5148\u8f29<\/span>\uff1a<br \/>\n\u3067\u306f\u554f\u984c\u3002CRISPR\/Cas9\u306b\u7d76\u5bfe\u306b\u5fc5\u8981\u306a\u3082\u306e\u306f2\u3064\u3067\u3059\u3002\u3055\u3066\u4f55\u3067\u3057\u3087\u3046\uff1f<\/p>\n<p><span style=\"color: #3366ff\">A\u3055\u3093<\/span>\uff1a<br \/>\n\u307e\u305a\u3001\u30b2\u30ce\u30e0\u3092\u5207\u65ad\u3059\u308b\u30cf\u30b5\u30df\u304c\u5fc5\u8981\u3067\u3059\u3088\u306d\u3001\u3053\u308c\u304cCas9\u3067\u3057\u305f\u3063\u3051\u3002\u3042\u3068\u306f\u2026\uff1f<\/p>\n<p><span style=\"color: #ff00ff\">\u5148\u8f29<\/span>\uff1a<br \/>\nCas9\u306f\u6b63\u89e3\u3002\u3082\u3046\u4e00\u3064\u306f\u30ac\u30a4\u30c9RNA\u3060\u3088\u3002\u5207\u65ad\u5834\u6240\u3092\u6c7a\u3081\u308b\u305f\u3081\u306e\u6848\u5185\u5f79\u306a\u3093\u3060\u3002<\/p>\n<p>\u5148\u8f29\u306e\u8a00\u3046\u3068\u304a\u308a\u3001Cas9\u3068\u30ac\u30a4\u30c9RNA\u304c\u30b2\u30ce\u30e0\u7de8\u96c6\u306e\u300c\u4e3b\u5f79\u300d\u3068\u8003\u3048\u307e\u3057\u3087\u3046\u3002<\/p>\n<ul>\n<li><b>Cas9\u30cc\u30af\u30ec\u30a2\u30fc\u30bc<\/b>\uff1a\u30b2\u30ce\u30e0\u3092\u5207\u65ad\u3059\u308b\u9175\u7d20\u3000\uff08\u30cf\u30b5\u30df\u306e\u5f79\uff09<\/li>\n<li><b>\u30ac\u30a4\u30c9RNA<\/b>\uff1a\u5207\u65ad\u90e8\u4f4d\u3092\u8a8d\u8b58\u3059\u308b\u5f79\u5272\u3092\u6301\u3063\u3066\u3044\u308bRNA \uff08\u6a19\u7684\u907a\u4f1d\u5b50\u3078\u306e\u6848\u5185\u5f79\uff09<\/li>\n<\/ul>\n<p>\u7d30\u80de\u5185\u3067\u3001Cas9\u30cc\u30af\u30ec\u30a2\u30fc\u30bc\u306f\u30ac\u30a4\u30c9RNA\u3068\u7d50\u5408\u3057\u3066\u3044\u307e\u3059\u3002\u30ac\u30a4\u30c9RNA\u304c\u76ee\u7684\u907a\u4f1d\u5b50\u306b\u7d50\u5408\u3059\u308b\u3068Cas9\u30cc\u30af\u30ec\u30a2\u30fc\u30bc\u304c\u305d\u3053\u306b\u30ea\u30af\u30eb\u30fc\u30c8\u3055\u308c\u3066\u30b2\u30ce\u30e0\u304c\u5207\u65ad\u3055\u308c\u307e\u3059\u3002<\/p>\n<p><span style=\"color: #ff00ff\">\u5148\u8f29<\/span>\uff1a<br \/>\n\u4e3b\u5f79\u306f\u3053\u306e2\u4eba\u3060\u3051\u3069\u30012\u4eba\u304c\u52d5\u304f\u821e\u53f0\uff08\u30b2\u30ce\u30e0\uff09\u306b\u3082\u91cd\u8981\u306a\u30dd\u30a4\u30f3\u30c8\u304c\u3042\u308b\u3093\u3060\u3002Cas9\u304cDNA\u5207\u65ad\u3092\u884c\u3046\u305f\u3081\u306b\u306f\u3001<b>\u30b2\u30ce\u30e0\u4e0a\u306bPAM\u914d\u5217\u304c\u5fc5\u8981<\/b>\u306a\u3093\u3060\u3088\u3002<\/p>\n<h2>\u30cf\u30b5\u30df\u5f79\uff1aCas9\u306b\u5fc5\u9808\u306aPAM\u914d\u5217<\/h2>\n<p>PAM\u914d\u5217\uff08\u30d7\u30ed\u30c8\u30b9\u30da\u30fc\u30b5\u30fc\u96a3\u63a5\u914d\u5217\uff09\u306f\u3001Cas9\u304c\u6a19\u7684\u306e\u4e8c\u672c\u9396\u914d\u5217\u3092\u8a8d\u8b58\u3059\u308b\u305f\u3081\u306b\u5fc5\u8981\u306a\u30b2\u30ce\u30e0\u4e0a\u306e\u914d\u5217\u3067\u3059\u3002\u305f\u3068\u3048\u3070\u3001\u5f93\u6765\u306eCas9\u306f\u3001SpCas9\u306f\u5316\u81bf\u6027\u9023\u9396\u7403\u83cc\u3001Streptococcus pyogenes\u306b\u7531\u6765\u3059\u308b\u30af\u30e9\u30b92\u306eType\u2161\u306e\u9175\u7d20\u3067\u3001\u307b\u304b\u306e\u56e0\u5b50\u3092\u5fc5\u8981\u3068\u305b\u305a\u5358\u72ec\u3067\u6d3b\u6027\u3092\u6301\u3064\u305f\u3081\u3001\u30b2\u30ce\u30e0\u7de8\u96c6\u7528\u306e\u30cc\u30af\u30ec\u30a2\u30fc\u30bc\u3068\u3057\u3066\u6700\u521d\u306b\u4f7f\u308f\u308c\u305f\u9175\u7d20\u3067\u3059\u3002SpCa9\u306ePAM\u914d\u5217\u306fNGG\uff08N\u306fA\u3001C\u3001G\u3001T\u3069\u306e\u5869\u57fa\u3067\u3082\u53ef\u80fd\uff09\u3067\u3059\u3002\u305d\u306e\u305f\u3081\u3001<u>SpCas9<\/u><u>\u3092\u4f7f\u7528\u3059\u308b\u30b2\u30ce\u30e0\u7de8\u96c6\u306b\u306f\u3001\u4e8c\u672c\u9396\u30b2\u30ce\u30e0\u306e\u3069\u3061\u3089\u304b\u306b<\/u><u>NGG<\/u><u>\u914d\u5217\u304c\u5fc5\u9808<\/u>\u3067\u3059\u3002<\/p>\n<div id=\"attachment_14490\" style=\"width: 571px\" class=\"wp-caption aligncenter\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-14490\" class=\"size-full wp-image-14490\" src=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2020\/10\/gene-editing_bid_ts_1-01.jpg\" alt=\"\u30bf\u30fc\u30b2\u30c3\u30c8\u914d\u5217\u3068PAM\u914d\u5217\" width=\"561\" height=\"153\" srcset=\"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2020\/10\/gene-editing_bid_ts_1-01.jpg 561w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2020\/10\/gene-editing_bid_ts_1-01-300x82.jpg 300w\" sizes=\"auto, (max-width: 561px) 100vw, 561px\" \/><p id=\"caption-attachment-14490\" class=\"wp-caption-text\">\u56f31\uff1a\u30bf\u30fc\u30b2\u30c3\u30c8\u914d\u5217\u3068PAM\u914d\u5217<\/p><\/div>\n<p><span style=\"color: #3366ff\">A\u3055\u3093<\/span>\uff1a<br \/>\n\u76ee\u7684\u907a\u4f1d\u5b50\u306bNGG\u3001\u3064\u307e\u308a\u300cGG\u300d\u304c\u306a\u304b\u3063\u305f\u3089\u3001CRISPR\u30b7\u30b9\u30c6\u30e0\u306f\u4f7f\u3048\u306a\u3044\u3063\u3066\u3053\u3068\u3067\u3059\u304b\uff1f\u3069\u3053\u3067\u3082\u5207\u308c\u308b\u308f\u3051\u3058\u3083\u306a\u3044\u3093\u3060\u3002<\/p>\n<p><span style=\"color: #ff00ff\">\u5148\u8f29<\/span>\uff1a<br \/>\nSpCas9\u306e\u5834\u5408\u306f\u3001\u305d\u3046\u306a\u308b\u306d\u3002\u3067\u3082SpCas9\u4ee5\u5916\u306eCas9\u3082\u3042\u308b\u3057\u3001\u6700\u8fd1\u306f\u307b\u304b\u306b\u3082Cas12\u3001Cas3\u306a\u3069\u591a\u304f\u306e\u30cc\u30af\u30ec\u30a2\u30fc\u30bc\u304c\u77e5\u3089\u308c\u308b\u3088\u3046\u306b\u306a\u3063\u3066\u3044\u3066\u3001\u305d\u308c\u305e\u308cPAM\u914d\u5217\u304c\u7570\u306a\u308b\u304b\u3089\u3001\u3053\u308c\u3089\u306e\u30cc\u30af\u30ec\u30a2\u30fc\u30bc\u3092\u7d44\u307f\u5408\u308f\u305b\u308c\u3070\u3001\u5e83\u7bc4\u56f2\u306b\u308f\u305f\u3063\u3066\u30b2\u30ce\u30e0\u7de8\u96c6\u304c\u3067\u304d\u308b\u67d4\u8edf\u306a\u30b7\u30b9\u30c6\u30e0\u306b\u306a\u308b\u3088\u3002<\/p>\n<table border=\"2\" cellpadding=\"10%\">\n<caption><strong>\u88681\u3000\u30b2\u30ce\u30e0\u7de8\u96c6\u306e3\u3064\u306e\u4f9b\u4e0e\u65b9\u6cd5<\/strong><\/caption>\n<caption style=\"text-align: left\">Type\u2161\u30cc\u30af\u30ec\u30a2\u30fc\u30bc<\/caption>\n<thead>\n<tr bgcolor=\"aliceblue\">\n<td style=\"text-align: center\" width=\"85\"><\/td>\n<td style=\"text-align: center\" width=\"96\">PAM\u914d\u5217<\/td>\n<td style=\"text-align: center\" width=\"121\">\u30a2\u30df\u30ce\u9178\u6570<\/td>\n<td style=\"text-align: center\" width=\"132\">\u30bf\u30fc\u30b2\u30c3\u30c8\u306b\u7d50\u5408\u3059\u308b\u30ac\u30a4\u30c9RNA\u306e\u9577\u3055\uff08crRNA\u9577\uff09<\/td>\n<td style=\"text-align: center\" width=\"208\">\u7279\u5fb4<\/td>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td width=\"85\">SpCas9<\/td>\n<td width=\"96\">NGG<\/td>\n<td width=\"121\">1368a.a\uff084.1 kbp\uff09<\/td>\n<td width=\"132\">19~20 nt<\/td>\n<td width=\"208\">\u5f93\u6765\u306e\u30cc\u30af\u30ec\u30a2\u30fc\u30bc<\/td>\n<\/tr>\n<tr>\n<td width=\"85\">SaCas9<\/td>\n<td width=\"96\">NNGRR(T)<\/td>\n<td width=\"121\">1053a.a\uff083.2 kbp\uff09<\/td>\n<td width=\"132\">20~22 nt<\/td>\n<td width=\"208\">\u30a2\u30c7\u30ce\u968f\u4f34\u30a6\u30a4\u30eb\u30b9\u306b\u30d1\u30c3\u30b1\u30fc\u30b8\u30f3\u30b0\u53ef\u80fd<\/td>\n<\/tr>\n<tr>\n<td width=\"85\">Cj Cas9<\/td>\n<td width=\"96\">NNNNRYAC<\/td>\n<td width=\"121\">984a.a\uff083.0 kbp\uff09<\/td>\n<td width=\"132\">21~23 nt<\/td>\n<td width=\"208\">\u5206\u5b50\u91cf\u304c\u975e\u5e38\u306b\u5c0f\u3055\u3044<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table border=\"2\" cellpadding=\"10%\">\n<caption style=\"text-align: left\">Type\u2164\u30cc\u30af\u30ec\u30a2\u30fc\u30bc<\/caption>\n<thead>\n<tr bgcolor=\"aliceblue\">\n<td style=\"text-align: center\" width=\"85\"><\/td>\n<td style=\"text-align: center\" width=\"96\">PAM\u914d\u5217<\/td>\n<td style=\"text-align: center\" width=\"121\">\u30a2\u30df\u30ce\u9178\u6570<\/td>\n<td style=\"text-align: center\" width=\"132\">\u30bf\u30fc\u30b2\u30c3\u30c8\u306b\u7d50\u5408\u3059\u308b\u30ac\u30a4\u30c9RNA\u306e\u9577\u3055\uff08crRNA\u9577\uff09<\/td>\n<td style=\"text-align: center\" width=\"208\">\u7279\u5fb4<\/td>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td width=\"85\">Cas12a<br \/>\n(Cpf1)<\/td>\n<td width=\"96\">TTN<\/td>\n<td width=\"121\">1307a.a\uff083.9 kbp\uff09<\/td>\n<td width=\"132\">20~23 nt<\/td>\n<td width=\"208\">sticky end\u3067\u5207\u65ad\u3001\u30ac\u30a4\u30c9RNA\u304c\u77ed\u3044\uff08~43 nt\uff09\u3001DETECTOR\u30b7\u30b9\u30c6\u30e0\u306b\u5fdc\u7528<\/td>\n<\/tr>\n<tr>\n<td width=\"85\">Cas14a<\/td>\n<td width=\"96\">TTTR<\/td>\n<td width=\"121\">530a.a<\/td>\n<td width=\"132\">20 nt<\/td>\n<td width=\"208\">1\u672c\u9396DNA\u3082\u5207\u65ad<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table border=\"2\" cellpadding=\"10%\">\n<caption style=\"text-align: left\">Type\u2165\u30cc\u30af\u30ec\u30a2\u30fc\u30bc<\/caption>\n<thead>\n<tr bgcolor=\"aliceblue\">\n<td style=\"text-align: center\" width=\"85\"><\/td>\n<td style=\"text-align: center\" width=\"96\">PAM\u914d\u5217<\/td>\n<td style=\"text-align: center\" width=\"121\">\u30a2\u30df\u30ce\u9178\u6570<\/td>\n<td style=\"text-align: center\" width=\"132\">\u30bf\u30fc\u30b2\u30c3\u30c8\u306b\u7d50\u5408\u3059\u308b\u30ac\u30a4\u30c9RNA\u306e\u9577\u3055\uff08crRNA\u9577\uff09<\/td>\n<td style=\"text-align: center\" width=\"208\">\u7279\u5fb4<\/td>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td width=\"85\">Cas13a<\/td>\n<td width=\"96\">3&#8242; A \/U\/C<\/td>\n<td width=\"121\">1160a.a<\/td>\n<td width=\"132\">28 nt<\/td>\n<td width=\"208\">1\u672c\u9396RNA\u3092\u5207\u65ad\u3001\u30ac\u30a4\u30c9RNA\u306e\u5916\u5074\u3092\u5207\u65ad\u3001SHERLOCK\u30b7\u30b9\u30c6\u30e0\u306b\u5fdc\u7528<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>\u203bnt=\u5869\u57fa<\/p>\n<p>\u88681\u306e\u3088\u3046\u306b\u3001SpCas9\u4ee5\u5916\u306b\u3082\u591a\u304f\u306e\u30cc\u30af\u30ec\u30a2\u30fc\u30bc\u304c\u77e5\u3089\u308c\u3066\u3044\u307e\u3059\u3002\u305d\u308c\u305e\u308cPAM\u914d\u5217\u3084\u5206\u5b50\u91cf\u306a\u3069\u7279\u5fb4\u304c\u3055\u307e\u3056\u307e\u3067\u3059\u3002<\/p>\n<p>\u305f\u3068\u3048\u3070<em>In vivo<\/em>\u3067CRISPR\/Cas9\u30b7\u30b9\u30c6\u30e0\u3092\u30c7\u30ea\u30d0\u30ea\u30fc\u3059\u308b\u5834\u5408\u3001\u30a2\u30c7\u30ce\u968f\u4f34\u30a6\u30a4\u30eb\u30b9\uff08AAV\uff09\u3092\u5229\u7528\u3059\u308b\u3053\u3068\u304c\u591a\u3044\u3067\u3059\u304c\u3001SpCas9\u3067\u306f\u5206\u5b50\u91cf\u304c\u5927\u304d\u304f\u30d1\u30c3\u30b1\u30fc\u30b8\u30f3\u30b0\u304c\u96e3\u3057\u3044\u305f\u3081\u3001\u3088\u308a\u5206\u5b50\u91cf\u304c\u5c0f\u3055\u306aSaCas9\u304c\u4f7f\u7528\u3055\u308c\u307e\u3059\u3002\u307e\u305f\u3001Cas12\uff08Cpf1\u3068\u3082\u547c\u3070\u308c\u307e\u3059\uff09\u306fPAM\u914d\u5217\u304cTTN\u3067\u3059\u3002\u3064\u307e\u308a\u3001SpCas9\u306ePAM\u914d\u5217\uff08NGG\uff09\u304c\u5229\u7528\u3067\u304d\u306a\u3044\u907a\u4f1d\u5b50\u3067\u3082\u3001TT\u304c\u5b58\u5728\u3059\u308c\u3070\u30b2\u30ce\u30e0\u7de8\u96c6\u304c\u53ef\u80fd\u3067\u3059\u3002\u307e\u305f\u3001Cas12\uff08Cpf1\uff09\u3067\u306f\u30ac\u30a4\u30c9RNA\u81ea\u4f53\u304c\u975e\u5e38\u306b\u77ed\u3044\uff0842\u5869\u57fa\uff09\u305f\u3081gRNA\u306e\u4f5c\u6210\u304c\u5bb9\u6613\u3068\u3044\u3046\u30e1\u30ea\u30c3\u30c8\u3082\u3042\u308a\u307e\u3059\u3002\u3053\u306e\u3088\u3046\u306bSpCas9\u4ee5\u5916\u306b\u3082\u591a\u304f\u306eCas9\u304c\u767a\u898b\u3055\u308c\u3066\u304a\u308a\u3001\u30b2\u30ce\u30e0\u4e0a\u306e\u591a\u304f\u306e\u90e8\u4f4d\u3067\u30b2\u30ce\u30e0\u7de8\u96c6\u3067\u304d\u308b\u3088\u3046\u67d4\u8edf\u6027\u304c\u9ad8\u304f\u306a\u3063\u3066\u304d\u3066\u3044\u307e\u3059\u3002<\/p>\n<h2>\u6a19\u7684\u914d\u5217\u307e\u3067\u306e\u6848\u5185\u5f79\uff1a\u30ac\u30a4\u30c9RNA\u306e\u4ed5\u7d44\u307f<\/h2>\n<p><span style=\"color: #3366ff\">A\u3055\u3093<\/span>\uff1a<br \/>\n\u88681\u3092\u898b\u308b\u3068\u3001\u30cc\u30af\u30ec\u30a2\u30fc\u30bc\u306e\u7a2e\u985e\u306b\u3088\u3063\u3066\u3001\u30ac\u30a4\u30c9RNA\u306e\u9577\u3055\u3082\u9055\u3046\u3093\u3067\u3059\u306d\u3002SpCas9\u306e\u30ac\u30a4\u30c9RNA\u306f19\uff5e20\u5869\u57fa\u3042\u308c\u3070\u3044\u3044\u3093\u3067\u3059\u304b\uff1f<\/p>\n<p><span style=\"color: #ff00ff\">\u5148\u8f29<\/span>\uff1a<br \/>\n\u3044\u3084\u300120\u5869\u57fa\u306b80\u5869\u57fa\u3092\u8db3\u3057\u3066\u3001\u5168\u9577100\u5869\u57fa\u304c\u5fc5\u8981\u306a\u3093\u3060\u3002\u3053\u3053\u306f\u3061\u3087\u3063\u3068\u308f\u304b\u308a\u306b\u304f\u3044\u3088\u306d\u3002\u56f32\u3092\u898b\u3066\u307f\u3088\u3046\u3002<\/p>\n<div id=\"attachment_7911\" style=\"width: 796px\" class=\"wp-caption aligncenter\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-7911\" class=\"wp-image-7911 size-full\" src=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2020\/10\/fig1.jpg\" alt=\"SpCas9\u306e\u30b2\u30ce\u30e0\u7de8\u96c6\u306e\u539f\u7406\" width=\"786\" height=\"496\" srcset=\"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2020\/10\/fig1.jpg 786w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2020\/10\/fig1-300x189.jpg 300w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2020\/10\/fig1-768x485.jpg 768w\" sizes=\"auto, (max-width: 786px) 100vw, 786px\" \/><p id=\"caption-attachment-7911\" class=\"wp-caption-text\">\u56f32\uff1aSpCas9\u306e\u30b2\u30ce\u30e0\u7de8\u96c6\u306e\u539f\u7406<\/p><\/div>\n<p>\u56f32\u306e\u3068\u304a\u308a\u3001\u30ac\u30a4\u30c9RNA\u306e\u3046\u3061\u30015\u2019\u5074\u306e19\u5869\u57fa\u307e\u305f\u306f20\u5869\u57fa\u306f\u76ee\u7684\u306e\u907a\u4f1d\u5b50\u306b\u5bfe\u3059\u308b\u76f8\u88dc\u914d\u5217\uff08Target complementary crRNA\uff1a<b>crRNA<\/b>\uff09\u306b\u306a\u308a\u30013\u2019\u5074\u306e80\u5869\u57fa\u306f\u30c8\u30e9\u30f3\u30b9\u6d3b\u6027\u5316\u578b\u914d\u5217\uff08Trans-activating crRNA\uff1a<b>tracrRNA<\/b>\uff09\u3068\u547c\u3070\u308c\u308bSpCas9\u304c\u7d50\u5408\u3059\u308b\u914d\u5217\u306b\u306a\u308a\u307e\u3059\u3002\u305d\u306e\u305f\u3081\u3001SpCas9\u306e\u30ac\u30a4\u30c9RNA\u306b\u306f100\u5869\u57fa\u306e\u4e00\u672c\u9396RNA\uff08single guide RNA\uff09\u304c\u4f7f\u7528\u3055\u308c\u3066\u304d\u307e\u3057\u305f\u3002\u305d\u308c\u305e\u308c\u306e\u5f79\u5272\u3092\u4e0b\u8a18\u306b\u307e\u3068\u3081\u307e\u3059\u3002<\/p>\n<ul>\n<li><b>crRNA\uff1a\u30ac\u30a4\u30c9RNA\u306e\u3046\u3061\u3001\u76ee\u7684\u907a\u4f1d\u5b50\u306b\u7d50\u5408\u3059\u308b\u914d\u5217<\/b><br \/>\ncrRNA\u914d\u5217\u306fPAM\u914d\u5217\u304c\u30b2\u30ce\u30e0\u4e0a\u306b\u591a\u304f\u5b58\u5728\u3057\u3066\u3044\u308c\u3070\u4f55\u901a\u308a\u3082\u30c7\u30b6\u30a4\u30f3\u3067\u304d\u307e\u3059\u304c\u3001\u3053\u306e\u914d\u5217\u306b\u3088\u3063\u3066\u5207\u65ad\u6d3b\u6027\u3068\u30aa\u30d5\u30bf\u30fc\u30b2\u30c3\u30c8\u5207\u65ad\u306e\u52b9\u7387\u304c\u5927\u304d\u304f\u7570\u306a\u308a\u307e\u3059\u3002\u30aa\u30d5\u30bf\u30fc\u30b2\u30c3\u30c8\u3068\u306f\u3001\u76ee\u7684\u907a\u4f1d\u5b50\u3068\u306f\u7570\u306a\u308b\u30b2\u30ce\u30e0\u914d\u5217\u4e0a\u3067\u5207\u65ad\u3068\u5909\u7570\u5c0e\u5165\u304c\u8d77\u304d\u308b\u73fe\u8c61\u3067\u3059\u3002crRNA\u914d\u5217\u306e\u7279\u7570\u6027\u304c\u4f4e\u3044\u3068\u30aa\u30d5\u30bf\u30fc\u30b2\u30c3\u30c8\u306b\u3088\u308b\u5909\u7570\u5c0e\u5165\u306e\u767a\u751f\u7387\u304c\u9ad8\u304f\u306a\u308a\u307e\u3059\u3002\u305d\u306e\u305f\u3081\u3001<a href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/life-science\/genome-editing\/invitrogen-truedesign-genome-editor.html?CID=bid_syn_gns_r04_jp_cp1361_pjt5742_bid00000_0so_blg_op_lgn_kt_s00_ge1_Social_LAB\" target=\"_blank\" rel=\"noopener\">Invitrogen\u2122 GeneArt\u2122 CRISPR Search and Design Tool<\/a>\u306e\u3088\u3046\u306a\u512a\u308c\u305f\u30c7\u30b6\u30a4\u30ca\u30fc\u30b5\u30a4\u30c8\u3092\u7528\u3044\u3066\u7279\u7570\u6027\u306e\u9ad8\u3044\u30ac\u30a4\u30c9RNA\u3092\u4f5c\u6210\u3059\u308b\u3053\u3068\u3092\u304a\u3059\u3059\u3081\u3057\u307e\u3059\uff08\u30c7\u30b6\u30a4\u30f3\u306e\u65b9\u6cd5\u306f\u3001<a href=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/gene-editing_bid_ts_2\/?CID=bid_syn_gns_r04_jp_cp1361_pjt5742_bid00000_0so_blg_op_lgn_kt_s00_ge1_Social_LAB\" target=\"_blank\" rel=\"noopener\">\u7b2c2\u56de<\/a>\u3067\u8a73\u3057\u304f\u3054\u7d39\u4ecb\u3057\u307e\u3059\uff09\u3002<\/li>\n<li><b>tracrRNA\uff1a\u30ac\u30a4\u30c9RNA\u306e\u3046\u3061\u3001Cas9\u304c\u7d50\u5408\u3059\u308b\u914d\u5217<\/b><br \/>\ntracrRNA\u914d\u5217\u306fSpCas9\u304c\u6d3b\u6027\u3092\u6301\u3064\u305f\u3081\u306b\u5fc5\u9808\u306a\u5171\u901a\u914d\u5217\u3067\u3001Cas9\u3068\u306e\u8907\u5408\u4f53\u3067\u306f\u30d8\u30a2\u30d4\u30f3\u69cb\u9020\u3092\u5f62\u6210\u3057\u307e\u3059\u3002\u56f32\u306e\u3088\u3046\u306b\u3001\u76ee\u7684\u306e\u907a\u4f1d\u5b50\u306bCas9\u30cc\u30af\u30ec\u30a2\u30fc\u30bc\u304c\u30ea\u30af\u30eb\u30fc\u30c8\u3055\u308c\u308b\u3068\u3001Cas9\u306b\u3088\u308a\u30b2\u30ce\u30e0\u304c\u5207\u65ad\u3055\u308c\u307e\u3059\u3002\u5207\u65ad\u90e8\u4f4d\u306fPAM\u914d\u5217\u306e\u4e0a\u6d413\u5869\u57fa\u76ee\u30684\u5869\u57fa\u76ee\u3067\u5207\u65ad\u3055\u308c\u307e\u3059\u306e\u3067\u3001\u5909\u7570\u306f\u3053\u306e\u5468\u8fba\u306b\u633f\u5165\u3055\u308c\u308b\u3053\u3068\u306b\u306a\u308a\u307e\u3059\u3002<\/li>\n<\/ul>\n<h2>\u30ce\u30c3\u30af\u30a2\u30a6\u30c8\u5b9f\u9a13\u3068\u30ce\u30c3\u30af\u30a4\u30f3\u5b9f\u9a13<\/h2>\n<p><span style=\"color: #3366ff\">A\u3055\u3093<\/span>\uff1a<br \/>\n\u3068\u3053\u308d\u3067\u5148\u8f29\u3001\u30b2\u30ce\u30e0\u7de8\u96c6\u306b\u306f\u30ce\u30c3\u30af\u30a4\u30f3\u5b9f\u9a13\u3068\u30ce\u30c3\u30af\u30a2\u30a6\u30c8\u5b9f\u9a13\u304c\u3042\u308a\u307e\u3059\u3088\u306d\u3002\u50d5\u306f\u5b9f\u9a13\u3067\u300c\u907a\u4f1d\u5b50\u306e\u6a5f\u80fd\u3092\u7834\u58ca\u300d\u3067\u304d\u308c\u3070\u3044\u3044\u3093\u3067\u3059\u304c\u3001\u3069\u3063\u3061\u306b\u306a\u308b\u3093\u3067\u3057\u3087\u3046\u3002<\/p>\n<p><span style=\"color: #ff00ff\">\u5148\u8f29<\/span>\uff1a<br \/>\n\u907a\u4f1d\u5b50\u306e\u6a5f\u80fd\u3092\u7834\u58ca\u3059\u308b\u3060\u3051\u306a\u3089\u3001\u76ee\u7684\u907a\u4f1d\u5b50\u914d\u5217\u306b\u30e9\u30f3\u30c0\u30e0\u5909\u7570\u3092\u8d77\u3053\u305b\u3070\u3044\u3044\u304b\u3089\u3001<b>\u30ce\u30c3\u30af\u30a2\u30a6\u30c8\u5b9f\u9a13<\/b>\u3067\u5341\u5206\u3060\u3088\u3002<\/p>\n<p><span style=\"color: #3366ff\">A\u3055\u3093<\/span>\uff1a<br \/>\n\u30e9\u30f3\u30c0\u30e0\u5909\u7570\u3063\u3066\u4f55\u3067\u3059\u304b\uff1f<\/p>\n<p><span style=\"color: #ff00ff\">\u5148\u8f29<\/span>\uff1a<br \/>\nCas9\u3067\u30b2\u30ce\u30e0\u304c\u5207\u65ad\u3055\u308c\u305f\u5f8c\u3001\u7d30\u80de\u5185\u3067\u5207\u65ad\u7b87\u6240\u306e\u4fee\u5fa9\u304c\u8d77\u3053\u308b\u3093\u3060\u3002\u305d\u306e\u3068\u304d\u3001\u5207\u65ad\u3055\u308c\u305f\u5834\u6240\u306b\u5909\u7570\u304c\u5165\u308b\u3053\u3068\u304c\u3042\u308b\u3093\u3060\u3088\u3002\u3053\u306e\u5909\u7570\u306f\u6b20\u5931\u306e\u3053\u3068\u3082\u3042\u308b\u3057\u633f\u5165\u306e\u3053\u3068\u3082\u3042\u308b\u3002\u30b3\u30f3\u30c8\u30ed\u30fc\u30eb\u3067\u304d\u306a\u3044\u3051\u3069\u3001\u6570\u5869\u57fa\u304b\u3089\u6570\u5341\u5869\u57fa\u306e\u5909\u7570\u304c\u5165\u308b\u3053\u3068\u304c\u591a\u3044\u3088\u3002<\/p>\n<div id=\"attachment_7908\" style=\"width: 438px\" class=\"wp-caption aligncenter\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-7908\" class=\"wp-image-7908 size-full\" src=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2020\/10\/fig2.jpg\" alt=\"CRISPR\/Cas9 \u30ce\u30c3\u30af\u30a2\u30a6\u30c8\u5b9f\u9a13\u3067\u5909\u7570\u304c\u5165\u308b\u4ed5\u7d44\u307f\" width=\"428\" height=\"331\" srcset=\"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2020\/10\/fig2.jpg 428w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2020\/10\/fig2-300x232.jpg 300w\" sizes=\"auto, (max-width: 428px) 100vw, 428px\" \/><p id=\"caption-attachment-7908\" class=\"wp-caption-text\">\u56f33\uff1aCRISPR\/Cas9 \u30ce\u30c3\u30af\u30a2\u30a6\u30c8\u5b9f\u9a13\u3067\u5909\u7570\u304c\u5165\u308b\u4ed5\u7d44\u307f<\/p><\/div>\n<p>\u30ce\u30c3\u30af\u30a2\u30a6\u30c8\u5b9f\u9a13\u3067\u5909\u7570\u304c\u5165\u308b\u4ed5\u7d44\u307f\u3092\u3001\u3082\u3046\u5c11\u3057\u8a73\u3057\u304f\u3054\u8aac\u660e\u3057\u307e\u3057\u3087\u3046\u3002<br \/>\n\u307e\u305a\u3001\u30ac\u30a4\u30c9RNA\u3068Cas9\u30cc\u30af\u30ec\u30a2\u30fc\u30bc\u304c\u7d30\u80de\u5185\u306b\u633f\u5165\u3055\u308c\u308b\u3068\u3001Cas9\u30cc\u30af\u30ec\u30a2\u30fc\u30bc\u306f\u30ac\u30a4\u30c9RNA\u3068\u7d50\u5408\u3057\u3066\u8907\u5408\u4f53\u3092\u5f62\u6210\u3057\u307e\u3059\u3002\u3053\u306e\u8907\u5408\u4f53\u306fCas9\u30cc\u30af\u30ec\u30a2\u30fc\u30bc\u672b\u7aef\u306e\u6838\u79fb\u884c\u30b7\u30b0\u30ca\u30eb\u306b\u3088\u308a\u6838\u306b\u79fb\u884c\u3057\u3001\u6838\u5185\u3067PAM\u914d\u5217\uff08NGG\uff09\u306b\u7d50\u5408\u3057\u307e\u3059\u3002Cas9\u30cc\u30af\u30ec\u30a2\u30fc\u30bc\u306f\u30b2\u30ce\u30e0DNA\u3092\u5dfb\u304d\u623b\u3059\u6d3b\u6027\u304c\u3042\u308b\u305f\u3081\u3001\u7d50\u5408\u3057\u305fPAM\u914d\u5217\u3068\u4e0a\u6d41\u306e\u4e8c\u672c\u9396\u30b2\u30ce\u30e0DNA\u304c1\u672c\u9396\u306b\u4e56\u96e2\u3057\u3001\u30ac\u30a4\u30c9RNA\u304c\u76f8\u88dc\u9396\u306e\u30b2\u30ce\u30e0\u3068\u7d50\u5408\u3057\u307e\u3059\u3002\u305d\u306e\u5f8c\u3001Cas9\u30cc\u30af\u30ec\u30a2\u30fc\u30bc\u306f\u76ee\u7684\u907a\u4f1d\u5b50\u306ePAM\u914d\u5217\u306e\u4e0a\u6d413\u5869\u57fa\u76ee\u30684\u5869\u57fa\u76ee\u3067\u30b2\u30ce\u30e0\u3092\u5207\u65ad\u3057\u307e\u3059\uff08\u30c0\u30d6\u30eb\u30b9\u30c8\u30e9\u30f3\u30c9\u30d6\u30ec\u30fc\u30af\u3001DSB\u3001\u3068\u547c\u3070\u308c\u307e\u3059\uff09\u3002\u5207\u65ad\u304c\u8d77\u3053\u3063\u3066\u3082\u3001\u901a\u5e38\u306f\u7d30\u80de\u5185\u306e\u4fee\u5fa9\u7d4c\u8def\uff08\u975e\u76f8\u540c\u672b\u7aef\u7d50\u5408\uff1bnon homologous end joint\uff09\u306b\u3088\u308a\u3082\u3068\u306e\u914d\u5217\u306b\u623b\u3055\u308c\u307e\u3059\u3002\u3068\u3053\u308d\u304c\u7d30\u80de\u5185\u306b\u30ac\u30a4\u30c9RNA\u3068Cas9\u306e\u8907\u5408\u4f53\u304c\u6b8b\u5b58\u3057\u3066\u3044\u308b\u3068\u518d\u5207\u65ad\u304c\u8d77\u304d\u307e\u3059\u3002<\/p>\n<p>\u3053\u3046\u3057\u3066\u5207\u65ad\u30fb\u4fee\u5fa9\u304c\u7e70\u308a\u8fd4\u3055\u308c\u308b\u9593\u306b\u3001\u4f4e\u3044\u78ba\u7387\u3067\u4fee\u5fa9\u30a8\u30e9\u30fc\u304c\u8d77\u304d\u5909\u7570\u304c\u5165\u308a\u307e\u3059\u3002\u3053\u306e\u5909\u7570\u306f\u30e9\u30f3\u30c0\u30e0\u306e\u305f\u3081\u3001\u3069\u306e\u3088\u3046\u306a\u5909\u7570\u306a\u306e\u304b\u3001\u6b20\u5931\u306a\u306e\u304b\u633f\u5165\u306a\u306e\u304b\u3001\u3069\u308c\u304f\u3089\u3044\u306e\u5869\u57fa\u6570\u3067\u5909\u7570\u304c\u5165\u308b\u306e\u304b\u3092\u30b3\u30f3\u30c8\u30ed\u30fc\u30eb\u3067\u304d\u307e\u305b\u3093\u3002\u305d\u306e\u305f\u3081\u3001\u6a39\u7acb\u3057\u305f\u30b2\u30ce\u30e0\u7de8\u96c6\u5909\u7570\u4f53\u306e\u5909\u7570\u90e8\u4f4d\u306e\u30b7\u30fc\u30b1\u30f3\u30b9\u3092\u884c\u3044\u5909\u7570\u306e\u78ba\u8a8d\u3092\u884c\u3044\u307e\u3059\u3002\u30b7\u30fc\u30b1\u30f3\u30b9\u306e\u7d50\u679c\u304b\u3089\u907a\u4f1d\u5b50\u306e\u4e21\u30a2\u30ec\u30eb\u306b\u5909\u7570\u304c\u5165\u3063\u305f\u306e\u304b\uff08\u30db\u30e2\u306e\u5909\u7570\uff09\u307e\u305f\u306f\u7247\u30a2\u30ec\u30eb\u306b\u5909\u7570\u304c\u633f\u5165\u3055\u308c\u305f\u306e\u304b\uff08\u30d8\u30c6\u30ed\u5909\u7570\uff09\u3082\u5224\u65ad\u3067\u304d\u307e\u3059\u3002\u5909\u7570\u306e\u78ba\u8a8d\u306b\u3064\u3044\u3066\u306f\u3001<a href=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/gene-editing_bid_ts_5\/?CID=bid_syn_gns_r04_jp_cp1361_pjt5742_bid00000_0so_blg_op_lgn_kt_s00_ge1_Social_LAB\" target=\"_blank\" rel=\"noopener\">\u7b2c5\u56de<\/a>\u3067\u8a73\u3057\u304f\u3054\u7d39\u4ecb\u3057\u307e\u3059\u3002<\/p>\n<p><span style=\"color: #3366ff\">A\u3055\u3093<\/span>\uff1a<br \/>\n\u306a\u308b\u307b\u3069\u3002<br \/>\n\u3058\u3083\u3042\u307e\u305a\u306f\u30ce\u30c3\u30af\u30a2\u30a6\u30c8\u5b9f\u9a13\u3092\u8a66\u3057\u3066\u307f\u307e\u3059\uff01<\/p>\n<p>\u4e00\u822c\u7684\u306b\u3001A\u3055\u3093\u306e\u3088\u3046\u306b\u30ce\u30c3\u30af\u30a2\u30a6\u30c8\u5b9f\u9a13\u3092\u884c\u3063\u3066\u3044\u308b\u7814\u7a76\u8005\u306e\u65b9\u304c\u307e\u3060\u307e\u3060\u591a\u3044\u305f\u3081\u3001\u3053\u306e\u30d6\u30ed\u30b0\u3067\u306f\u3001\u30ce\u30c3\u30af\u30a2\u30a6\u30c8\u5b9f\u9a13\u306e\u30b2\u30ce\u30e0\u7de8\u96c6\u65b9\u6cd5\u3092\u3054\u7d39\u4ecb\u3057\u3066\u3044\u304d\u307e\u3059\u3002\u306a\u304a\u3001\u30ce\u30c3\u30af\u30a4\u30f3\u5b9f\u9a13\u306e\u5834\u5408\u306f\u3001Cas9\u3068\u30ac\u30a4\u30c9RNA\u306b\u52a0\u3048\u3001\u30c9\u30ca\u30fcDNA\u3082\u5fc5\u8981\u306b\u306a\u308a\u307e\u3059\u304c\u3001\u8a73\u3057\u304f\u306f\u7b2c7\u56de\u3067\u7d39\u4ecb\u3057\u307e\u3059\u3002<\/p>\n<h2>\u307e\u3068\u3081\uff1a\u30b2\u30ce\u30e0\u7de8\u96c6\u306e\u4e3b\u5f79\u306fCas9\u3068\u30ac\u30a4\u30c9RNA<\/h2>\n<p>A\u541b\u306b\u3088\u308b\u300c\u306f\u3058\u3081\u3066\u306e\u30b2\u30ce\u30e0\u7de8\u96c6\u5b9f\u9a13\u300d\u3067\u306f\u3001\u307e\u305a\u306f\u30b2\u30ce\u30e0\u7de8\u96c6\u306e\u4e3b\u5f79\u3084\u821e\u53f0\u3092\u7406\u89e3\u3059\u308b\u3068\u3053\u308d\u304b\u3089\u59cb\u307e\u308a\u307e\u3057\u305f\u3002\u30b2\u30ce\u30e0\u7de8\u96c6\u3067\u306f\u3001\u30b2\u30ce\u30e0\u3092\u5207\u65ad\u3059\u308b\u30cf\u30b5\u30df\u5f79\u3067\u3042\u308bCas9\u30cc\u30af\u30ec\u30a2\u30fc\u30bc\u3001\u305d\u308c\u306b\u6a19\u7684\u914d\u5217\u307e\u3067\u306e\u6848\u5185\u5f79\u3067\u3042\u308b\u30ac\u30a4\u30c9RNA\u3001\u3053\u306e2\u4eba\u304c\u4e3b\u5f79\u3067\u3059\u3002\u3053\u308c\u3089\u304c\u52d5\u304f\u821e\u53f0\uff08\u30b2\u30ce\u30e0\uff09\u4e0a\u3067\u5fc5\u8981\u306a\u306e\u306fPAM\u914d\u5217\u3002\u3053\u306e\u914d\u5217\u306f\u30cc\u30af\u30ec\u30a2\u30fc\u30bc\u306e\u7a2e\u985e\u306b\u3088\u3063\u3066\u7570\u306a\u308b\u3053\u3068\u304c\u308f\u304b\u308a\u307e\u3057\u305f\u3002<\/p>\n<p><span style=\"color: #3366ff\">A\u3055\u3093<\/span>\uff1a<br \/>\n\u3060\u3044\u3076\u308f\u304b\u3063\u3066\u304d\u307e\u3057\u305f\u3002\u8a66\u3057\u306bSpCas9\u3067\u30ac\u30a4\u30c9RNA\u304c\u30c7\u30b6\u30a4\u30f3\u3067\u304d\u308b\u304b\u3001\u8a66\u3057\u3066\u307f\u3088\u3046\u304b\u306a\u2026\u3002\u3082\u3057PAM\u914d\u5217\u306eGG\u304c\u306a\u3051\u308c\u3070\u3001\u5225\u306eCas9\u3092\u8a66\u3057\u3066\u307f\u308b\u3053\u3068\u306b\u3057\u307e\u3059\u3002<\/p>\n<p><span style=\"color: #ff00ff\">\u5148\u8f29<\/span>\uff1a<br \/>\n\u3044\u3044\u3068\u601d\u3046\u3088\u3002\u3058\u3083\u3042<a href=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/gene-editing_bid_ts_2\/?CID=bid_syn_gns_r04_jp_cp1361_pjt5742_bid00000_0so_blg_op_lgn_kt_s00_ge1_Social_LAB\" rel=\"noopener\" target=\"_blank\">\u6b21\u56de<\/a>\u306f\u30ac\u30a4\u30c9RNA\u30c7\u30b6\u30a4\u30f3\u65b9\u6cd5\u3084\u30c4\u30fc\u30eb\u306b\u3064\u3044\u3066\u304a\u8a71\u3057\u3088\u3046\u304b\u3002<\/p>\n<p>\uff1c\u30b2\u30ce\u30e0\u7de8\u96c6\u5b9f\u9a13\u30b7\u30ea\u30fc\u30ba\uff1e<br \/>\n\u305d\u3046\u3044\u3046\u3053\u3068\u3060\u3063\u305f\u306e\u304b ! \u30b2\u30ce\u30e0\u7de8\u96c6\u5b9f\u9a13\uff08CRISPR\/Cas9\uff09 \uff5e\u7b2c1\u56de\u3000CRISPR\/Cas9\u30b7\u30b9\u30c6\u30e0\u306e\u539f\u7406\uff5e<br \/>\n<a href=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/gene-editing_bid_ts_2\/?CID=bid_syn_gns_r04_jp_cp1361_pjt5742_bid00000_0so_blg_op_lgn_kt_s00_ge1_Social_LAB\" target=\"_blank\" rel=\"noopener\">\u305d\u3046\u3044\u3046\u3053\u3068\u3060\u3063\u305f\u306e\u304b ! \u30b2\u30ce\u30e0\u7de8\u96c6\u5b9f\u9a13\uff08CRISPR\/Cas9\uff09 \uff5e\u7b2c2\u56de\u3000\u30ac\u30a4\u30c9RNA\u306e\u30c7\u30b6\u30a4\u30f3\uff5e<\/a><br \/>\n<a href=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/gene-editing_bid_ts_3\/?CID=bid_syn_gns_r04_jp_cp1361_pjt5742_bid00000_0so_blg_op_lgn_kt_s00_ge1_Social_LAB\" target=\"_blank\" rel=\"noopener\">\u305d\u3046\u3044\u3046\u3053\u3068\u3060\u3063\u305f\u306e\u304b ! \u30b2\u30ce\u30e0\u7de8\u96c6\u5b9f\u9a13\uff08CRISPR\/Cas9\uff09 \uff5e\u7b2c3\u56de\u30003\u3064\u306eCRIPSR\/Cas9\u5b9f\u9a13\u7cfb\uff5e<\/a><br \/>\n<a href=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/gene-editing_bid_ts_4\/?CID=bid_syn_gns_r04_jp_cp1361_pjt5742_bid00000_0so_blg_op_lgn_kt_s00_ge1_Social_LAB\" target=\"_blank\" rel=\"noopener\">\u305d\u3046\u3044\u3046\u3053\u3068\u3060\u3063\u305f\u306e\u304b ! \u30b2\u30ce\u30e0\u7de8\u96c6\u5b9f\u9a13\uff08CRISPR\/Cas9\uff09 \uff5e\u7b2c4\u56de\u3000\u30c8\u30e9\u30f3\u30b9\u30d5\u30a7\u30af\u30b7\u30e7\u30f3\uff5e<\/a><br \/>\n<a href=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/gene-editing_bid_ts_5\/?CID=bid_syn_gns_r04_jp_cp1361_pjt5742_bid00000_0so_blg_op_lgn_kt_s00_ge1_Social_LAB\" target=\"_blank\" rel=\"noopener\">\u305d\u3046\u3044\u3046\u3053\u3068\u3060\u3063\u305f\u306e\u304b ! \u30b2\u30ce\u30e0\u7de8\u96c6\u5b9f\u9a13\uff08CRISPR\/Cas9\uff09 \uff5e\u7b2c5\u56de\u3000\u5909\u7570\u306e\u78ba\u8a8d\u65b9\u6cd5\uff5e<\/a><br \/>\n<a href=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/gene-editing_bid_ts_6\/?CID=bid_syn_gns_r04_jp_cp1361_pjt5742_bid00000_0so_blg_op_lgn_kt_s00_ge1_Social_LAB\" target=\"_blank\" rel=\"noopener\">\u305d\u3046\u3044\u3046\u3053\u3068\u3060\u3063\u305f\u306e\u304b ! \u30b2\u30ce\u30e0\u7de8\u96c6\u5b9f\u9a13\uff08CRISPR\/Cas9\uff09 \uff5e\u7b2c6\u56de\u3000\u30aa\u30d5\u30bf\u30fc\u30b2\u30c3\u30c8\u52b9\u679c\uff5e<\/a><br \/>\n<a href=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/gene-editing_bid_ts_7\/?CID=bid_syn_gns_r04_jp_cp1361_pjt5742_bid00000_0so_blg_op_lgn_kt_s00_ge1_Social_LAB\" target=\"_blank\" rel=\"noopener\">\u305d\u3046\u3044\u3046\u3053\u3068\u3060\u3063\u305f\u306e\u304b ! \u30b2\u30ce\u30e0\u7de8\u96c6\u5b9f\u9a13\uff08CRISPR\/Cas9\uff09 \uff5e\u7b2c7\u56de\u3000\u30ce\u30c3\u30af\u30a4\u30f3\uff5e<\/a><\/p>\n<p>\uff1c\u30b2\u30ce\u30e0\u7de8\u96c6\u306e\u57fa\u790e\u7684\u306a\u5185\u5bb9\uff1e<br \/>\n<a href=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/crispr-cas9_basic_bid_ts_1\/?CID=bid_syn_gns_r04_jp_cp1361_pjt5742_bid00000_0so_blg_op_lgn_kt_s00_ge1_Social_LAB\" target=\"_blank\" rel=\"noopener\">\u30b2\u30ce\u30e0\u7de8\u96c6\u306e\u539f\u7406\u3068\u624b\u5f15\u304d<\/a><\/p>\n<h3>\u5b9f\u969b\u306bCRISPR\/Cas9\u30b2\u30ce\u30e0\u7de8\u96c6\u3092\u59cb\u3081\u308b\u65b9\u306b\u304a\u3059\u3059\u3081\uff01<\/h3>\n<p>\u30c8\u30ec\u30fc\u30cb\u30f3\u30b0\u3068\u8a66\u85ac\u304c\u30bb\u30c3\u30c8\u306b\u306a\u3063\u305f\u30b2\u30ce\u30e0\u7de8\u96c6\u5b9f\u9a13\u30b9\u30bf\u30fc\u30bf\u30fc\u30d1\u30c3\u30af<\/p>\n<p><a class=\"btn btn-red\" href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/products-and-services\/services\/technical-services\/starter-pack.html?CID=bid_syn_gns_r04_jp_cp1361_pjt5742_bid00000_0so_blg_op_lgn_kt_s00_ge1_Social_LAB\" target=\"_blank\" rel=\"noopener noreferrer\">\u8a73\u7d30\u3092\u898b\u308b<\/a><\/p>\n<h3>\uff3b\u7121\u6599\u516c\u958b\u4e2d\uff3dCRISPR\u30b2\u30ce\u30e0\u7de8\u96c6\u30ea\u30bd\u30fc\u30b9\u30ac\u30a4\u30c9<\/h3>\n<p>\u30b2\u30ce\u30e0\u7de8\u96c6\u306e\u57fa\u790e\u306e\u5fa9\u7fd2\u3001\u3088\u308a\u6df1\u3044\u77e5\u8b58\u306e\u7372\u5f97\u3001\u307e\u305f\u306f\u6700\u65b0\u306e\u7814\u7a76\u30c4\u30fc\u30eb\u306e\u691c\u7d22\u304c\u3067\u304d\u307e\u3059\u3002\u30b2\u30ce\u30e0\u7de8\u96c6\u306e\u4e2d\u6838\u3068\u3057\u3066\u3001\u521d\u5fc3\u8005\u304b\u3089\u7d4c\u9a13\u8005\u307e\u3067\u3001\u8c4a\u5bcc\u3067\u4fe1\u983c\u3067\u304d\u308b\u6280\u8853\u7684\u306a\u5185\u5bb9\u3092\u63d0\u4f9b\u3057\u3066\u3044\u307e\u3059\u3002<\/p>\n<p><a class=\"btn btn-red\" href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/global\/forms\/genome-editing-resource-guide-form-download.html?CID=bid_syn_gns_r04_jp_cp1361_pjt5742_bid00000_0so_blg_op_lgn_kt_s00_ge1_Social_LAB\" target=\"_blank\" rel=\"noopener noreferrer\">\u30c0\u30a6\u30f3\u30ed\u30fc\u30c9\u3059\u308b<\/a><\/p>\n<p>\u7814\u7a76\u7528\u306b\u306e\u307f\u4f7f\u7528\u3067\u304d\u307e\u3059\u3002\u8a3a\u65ad\u7528\u306b\u306f\u4f7f\u7528\u3044\u305f\u3060\u3051\u307e\u305b\u3093\u3002<\/p>\n","protected":false},"excerpt":{"rendered":"<p>\u306f\u3058\u3081\u306b A\u3055\u3093\u306f\u3053\u308c\u304b\u3089\u30b2\u30ce\u30e0\u7de8\u96c6\u3092\u5229\u7528\u3057\u3066\u907a\u4f1d\u5b50\u3092\u89e3\u6790\u3057\u305f\u3044\u3068\u8003\u3048\u3066\u3044\u307e\u3059\u3002\u3088\u304f\u8033\u306b\u3059\u308bCRISPR\/Cas9\u3067\u5b9f\u65bd\u3057\u305f\u3044\u306e\u3067\u3059\u304c\u3001\u4f55\u304b\u3089\u624b\u3092\u3064\u3051\u3066\u3044\u3044\u306e\u304b\u308f\u304b\u308a\u307e\u305b\u3093\u3002CRISPR\u3068\u306f\uff1fCas9\u30cc\u30af\u30ec\u30a2\u30fc\u30bc\u3068\u306f\uff1f\u7591<\/p>\n","protected":false},"author":975,"featured_media":10134,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_monsterinsights_skip_tracking":false,"_genesis_hide_title":false,"_genesis_hide_breadcrumbs":false,"_genesis_hide_singular_image":false,"_genesis_hide_footer_widgets":false,"_genesis_custom_body_class":"","_genesis_custom_post_class":"","_genesis_layout":"","_jetpack_newsletter_access":"","_jetpack_dont_email_post_to_subs":false,"_jetpack_newsletter_tier_id":0,"_jetpack_memberships_contains_paywalled_content":false,"_jetpack_feature_clip_id":0,"_jetpack_memberships_contains_paid_content":false,"footnotes":"","jetpack_post_was_ever_published":false},"categories":[156],"tags":[190,175],"division":[],"class_list":{"0":"post-7841","1":"post","2":"type-post","3":"status-publish","4":"format-standard","5":"has-post-thumbnail","7":"category-mol-bio","8":"tag-crispr-cas9","9":"tag-genome-editing","10":"entry"},"_selected_authors":"","_selected_reviewers":"","acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v27.8 (Yoast SEO v27.8) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>\u305d\u3046\u3044\u3046\u3053\u3068\u3060\u3063\u305f\u306e\u304b ! \u30b2\u30ce\u30e0\u7de8\u96c6\u5b9f\u9a13\uff08CRISPR\/Cas9\uff09 \uff5e\u7b2c1\u56de\u3000CRISPR\/Cas9\u30b7\u30b9\u30c6\u30e0\u306e\u539f\u7406\uff5e - Learning at the Bench<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/gene-editing_bid_ts_1\/\" \/>\n<meta property=\"og:locale\" content=\"ja_JP\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"\u305d\u3046\u3044\u3046\u3053\u3068\u3060\u3063\u305f\u306e\u304b ! \u30b2\u30ce\u30e0\u7de8\u96c6\u5b9f\u9a13\uff08CRISPR\/Cas9\uff09 \uff5e\u7b2c1\u56de\u3000CRISPR\/Cas9\u30b7\u30b9\u30c6\u30e0\u306e\u539f\u7406\uff5e\" \/>\n<meta property=\"og:description\" content=\"\u306f\u3058\u3081\u306b A\u3055\u3093\u306f\u3053\u308c\u304b\u3089\u30b2\u30ce\u30e0\u7de8\u96c6\u3092\u5229\u7528\u3057\u3066\u907a\u4f1d\u5b50\u3092\u89e3\u6790\u3057\u305f\u3044\u3068\u8003\u3048\u3066\u3044\u307e\u3059\u3002\u3088\u304f\u8033\u306b\u3059\u308bCRISPR\/Cas9\u3067\u5b9f\u65bd\u3057\u305f\u3044\u306e\u3067\u3059\u304c\u3001\u4f55\u304b\u3089\u624b\u3092\u3064\u3051\u3066\u3044\u3044\u306e\u304b\u308f\u304b\u308a\u307e\u305b\u3093\u3002CRISPR\u3068\u306f\uff1fCas9\u30cc\u30af\u30ec\u30a2\u30fc\u30bc\u3068\u306f\uff1f\u7591\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/gene-editing_bid_ts_1\/\" \/>\n<meta property=\"og:site_name\" content=\"Learning at the Bench\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/ThermoFisherJapan\" \/>\n<meta property=\"article:published_time\" content=\"2020-10-08T04:44:38+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2025-02-10T05:31:33+00:00\" \/>\n<meta property=\"og:image\" content=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2020\/10\/shutterstock_1483033733-scaled.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"2560\" \/>\n\t<meta property=\"og:image:height\" content=\"1950\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"LatB Staff\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:creator\" content=\"@ThermoFisherJP\" \/>\n<meta name=\"twitter:site\" content=\"@ThermoFisherJP\" \/>\n<meta name=\"twitter:label1\" content=\"\u57f7\u7b46\u8005\" \/>\n\t<meta name=\"twitter:data1\" content=\"LatB Staff\" \/>\n\t<meta name=\"twitter:label2\" content=\"\u63a8\u5b9a\u8aad\u307f\u53d6\u308a\u6642\u9593\" \/>\n\t<meta name=\"twitter:data2\" content=\"15\u5206\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/gene-editing_bid_ts_1\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/gene-editing_bid_ts_1\\\/\"},\"author\":{\"name\":\"LatB Staff\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#\\\/schema\\\/person\\\/bdbe319a2001f279ddce6ab8eaad1253\"},\"headline\":\"\u305d\u3046\u3044\u3046\u3053\u3068\u3060\u3063\u305f\u306e\u304b ! \u30b2\u30ce\u30e0\u7de8\u96c6\u5b9f\u9a13\uff08CRISPR\\\/Cas9\uff09 \uff5e\u7b2c1\u56de\u3000CRISPR\\\/Cas9\u30b7\u30b9\u30c6\u30e0\u306e\u539f\u7406\uff5e\",\"datePublished\":\"2020-10-08T04:44:38+00:00\",\"dateModified\":\"2025-02-10T05:31:33+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/gene-editing_bid_ts_1\\\/\"},\"wordCount\":284,\"commentCount\":0,\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/gene-editing_bid_ts_1\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2020\\\/10\\\/shutterstock_1483033733-scaled.jpg\",\"keywords\":[\"CRISPR\\\/CAS9\",\"\u30b2\u30ce\u30e0\u7de8\u96c6\"],\"articleSection\":[\"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023\"],\"inLanguage\":\"ja\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/gene-editing_bid_ts_1\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/gene-editing_bid_ts_1\\\/\",\"url\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/gene-editing_bid_ts_1\\\/\",\"name\":\"\u305d\u3046\u3044\u3046\u3053\u3068\u3060\u3063\u305f\u306e\u304b ! \u30b2\u30ce\u30e0\u7de8\u96c6\u5b9f\u9a13\uff08CRISPR\\\/Cas9\uff09 \uff5e\u7b2c1\u56de\u3000CRISPR\\\/Cas9\u30b7\u30b9\u30c6\u30e0\u306e\u539f\u7406\uff5e - Learning at the Bench\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/gene-editing_bid_ts_1\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/gene-editing_bid_ts_1\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2020\\\/10\\\/shutterstock_1483033733-scaled.jpg\",\"datePublished\":\"2020-10-08T04:44:38+00:00\",\"dateModified\":\"2025-02-10T05:31:33+00:00\",\"author\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#\\\/schema\\\/person\\\/bdbe319a2001f279ddce6ab8eaad1253\"},\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/gene-editing_bid_ts_1\\\/#breadcrumb\"},\"inLanguage\":\"ja\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/gene-editing_bid_ts_1\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"ja\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/gene-editing_bid_ts_1\\\/#primaryimage\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2020\\\/10\\\/shutterstock_1483033733-scaled.jpg\",\"contentUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2020\\\/10\\\/shutterstock_1483033733-scaled.jpg\",\"width\":2560,\"height\":1950},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/gene-editing_bid_ts_1\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"\u305d\u3046\u3044\u3046\u3053\u3068\u3060\u3063\u305f\u306e\u304b ! \u30b2\u30ce\u30e0\u7de8\u96c6\u5b9f\u9a13\uff08CRISPR\\\/Cas9\uff09 \uff5e\u7b2c1\u56de\u3000CRISPR\\\/Cas9\u30b7\u30b9\u30c6\u30e0\u306e\u539f\u7406\uff5e\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#website\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/\",\"name\":\"Learning at the Bench\",\"description\":\"\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"ja\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#\\\/schema\\\/person\\\/bdbe319a2001f279ddce6ab8eaad1253\",\"name\":\"LatB Staff\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"ja\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g\",\"caption\":\"LatB Staff\"},\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/author\\\/lgbadmin\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"\u305d\u3046\u3044\u3046\u3053\u3068\u3060\u3063\u305f\u306e\u304b ! \u30b2\u30ce\u30e0\u7de8\u96c6\u5b9f\u9a13\uff08CRISPR\/Cas9\uff09 \uff5e\u7b2c1\u56de\u3000CRISPR\/Cas9\u30b7\u30b9\u30c6\u30e0\u306e\u539f\u7406\uff5e - Learning at the Bench","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/gene-editing_bid_ts_1\/","og_locale":"ja_JP","og_type":"article","og_title":"\u305d\u3046\u3044\u3046\u3053\u3068\u3060\u3063\u305f\u306e\u304b ! \u30b2\u30ce\u30e0\u7de8\u96c6\u5b9f\u9a13\uff08CRISPR\/Cas9\uff09 \uff5e\u7b2c1\u56de\u3000CRISPR\/Cas9\u30b7\u30b9\u30c6\u30e0\u306e\u539f\u7406\uff5e","og_description":"\u306f\u3058\u3081\u306b A\u3055\u3093\u306f\u3053\u308c\u304b\u3089\u30b2\u30ce\u30e0\u7de8\u96c6\u3092\u5229\u7528\u3057\u3066\u907a\u4f1d\u5b50\u3092\u89e3\u6790\u3057\u305f\u3044\u3068\u8003\u3048\u3066\u3044\u307e\u3059\u3002\u3088\u304f\u8033\u306b\u3059\u308bCRISPR\/Cas9\u3067\u5b9f\u65bd\u3057\u305f\u3044\u306e\u3067\u3059\u304c\u3001\u4f55\u304b\u3089\u624b\u3092\u3064\u3051\u3066\u3044\u3044\u306e\u304b\u308f\u304b\u308a\u307e\u305b\u3093\u3002CRISPR\u3068\u306f\uff1fCas9\u30cc\u30af\u30ec\u30a2\u30fc\u30bc\u3068\u306f\uff1f\u7591","og_url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/gene-editing_bid_ts_1\/","og_site_name":"Learning at the Bench","article_publisher":"https:\/\/www.facebook.com\/ThermoFisherJapan","article_published_time":"2020-10-08T04:44:38+00:00","article_modified_time":"2025-02-10T05:31:33+00:00","og_image":[{"width":2560,"height":1950,"url":"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2020\/10\/shutterstock_1483033733-scaled.jpg","type":"image\/jpeg"}],"author":"LatB Staff","twitter_card":"summary_large_image","twitter_creator":"@ThermoFisherJP","twitter_site":"@ThermoFisherJP","twitter_misc":{"\u57f7\u7b46\u8005":"LatB Staff","\u63a8\u5b9a\u8aad\u307f\u53d6\u308a\u6642\u9593":"15\u5206"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/gene-editing_bid_ts_1\/#article","isPartOf":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/gene-editing_bid_ts_1\/"},"author":{"name":"LatB Staff","@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#\/schema\/person\/bdbe319a2001f279ddce6ab8eaad1253"},"headline":"\u305d\u3046\u3044\u3046\u3053\u3068\u3060\u3063\u305f\u306e\u304b ! \u30b2\u30ce\u30e0\u7de8\u96c6\u5b9f\u9a13\uff08CRISPR\/Cas9\uff09 \uff5e\u7b2c1\u56de\u3000CRISPR\/Cas9\u30b7\u30b9\u30c6\u30e0\u306e\u539f\u7406\uff5e","datePublished":"2020-10-08T04:44:38+00:00","dateModified":"2025-02-10T05:31:33+00:00","mainEntityOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/gene-editing_bid_ts_1\/"},"wordCount":284,"commentCount":0,"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/gene-editing_bid_ts_1\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2020\/10\/shutterstock_1483033733-scaled.jpg","keywords":["CRISPR\/CAS9","\u30b2\u30ce\u30e0\u7de8\u96c6"],"articleSection":["\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023"],"inLanguage":"ja","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/gene-editing_bid_ts_1\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/gene-editing_bid_ts_1\/","url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/gene-editing_bid_ts_1\/","name":"\u305d\u3046\u3044\u3046\u3053\u3068\u3060\u3063\u305f\u306e\u304b ! \u30b2\u30ce\u30e0\u7de8\u96c6\u5b9f\u9a13\uff08CRISPR\/Cas9\uff09 \uff5e\u7b2c1\u56de\u3000CRISPR\/Cas9\u30b7\u30b9\u30c6\u30e0\u306e\u539f\u7406\uff5e - Learning at the Bench","isPartOf":{"@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/gene-editing_bid_ts_1\/#primaryimage"},"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/gene-editing_bid_ts_1\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2020\/10\/shutterstock_1483033733-scaled.jpg","datePublished":"2020-10-08T04:44:38+00:00","dateModified":"2025-02-10T05:31:33+00:00","author":{"@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#\/schema\/person\/bdbe319a2001f279ddce6ab8eaad1253"},"breadcrumb":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/gene-editing_bid_ts_1\/#breadcrumb"},"inLanguage":"ja","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/gene-editing_bid_ts_1\/"]}]},{"@type":"ImageObject","inLanguage":"ja","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/gene-editing_bid_ts_1\/#primaryimage","url":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2020\/10\/shutterstock_1483033733-scaled.jpg","contentUrl":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2020\/10\/shutterstock_1483033733-scaled.jpg","width":2560,"height":1950},{"@type":"BreadcrumbList","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/gene-editing_bid_ts_1\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/"},{"@type":"ListItem","position":2,"name":"\u305d\u3046\u3044\u3046\u3053\u3068\u3060\u3063\u305f\u306e\u304b ! \u30b2\u30ce\u30e0\u7de8\u96c6\u5b9f\u9a13\uff08CRISPR\/Cas9\uff09 \uff5e\u7b2c1\u56de\u3000CRISPR\/Cas9\u30b7\u30b9\u30c6\u30e0\u306e\u539f\u7406\uff5e"}]},{"@type":"WebSite","@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#website","url":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/","name":"Learning at the Bench","description":"","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"ja"},{"@type":"Person","@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#\/schema\/person\/bdbe319a2001f279ddce6ab8eaad1253","name":"LatB Staff","image":{"@type":"ImageObject","inLanguage":"ja","@id":"https:\/\/secure.gravatar.com\/avatar\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g","caption":"LatB Staff"},"url":"https:\/\/admin.acceleratingscience.com\/author\/lgbadmin\/"}]}},"taxonomy_info":{"category":[{"value":156,"label":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023"}],"post_tag":[{"value":190,"label":"CRISPR\/CAS9"},{"value":175,"label":"\u30b2\u30ce\u30e0\u7de8\u96c6"}]},"featured_image_src_large":["https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2020\/10\/shutterstock_1483033733-1024x780.jpg",760,579,true],"author_info":{"display_name":"LatB Staff","author_link":"https:\/\/admin.acceleratingscience.com\/author\/lgbadmin\/"},"comment_info":5,"category_info":[{"term_id":156,"name":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","slug":"mol-bio","term_group":0,"term_taxonomy_id":156,"taxonomy":"category","description":"","parent":0,"count":538,"filter":"raw","meta":[],"cat_ID":156,"category_count":538,"category_description":"","cat_name":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","category_nicename":"mol-bio","category_parent":0}],"tag_info":[{"term_id":190,"name":"CRISPR\/CAS9","slug":"crispr-cas9","term_group":0,"term_taxonomy_id":190,"taxonomy":"post_tag","description":"","parent":0,"count":9,"filter":"raw","meta":[]},{"term_id":175,"name":"\u30b2\u30ce\u30e0\u7de8\u96c6","slug":"genome-editing","term_group":0,"term_taxonomy_id":175,"taxonomy":"post_tag","description":"","parent":0,"count":14,"filter":"raw","meta":[]}],"jetpack-related-posts":[{"id":23864,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/protein-expression-cloning-bid-ts-mbr-25070\/","url_meta":{"origin":7841,"position":0},"title":"\u521d\u5fc3\u8005\u3067\u3082\u5b89\u5fc3\uff01\u7c21\u5358\u306b\u3067\u304d\u308b\u767a\u73fe\u30d9\u30af\u30bf\u30fc\u306e\u4f5c\u308a\u65b9\uff1a\u4eba\u5de5\u907a\u4f1d\u5b50\u5408\u6210\u30b5\u30fc\u30d3\u30b9\u306e\u5229\u7528\u6cd5","author":"LatB Staff","date":"2025\u5e7411\u670813\u65e5","format":false,"excerpt":"\u30bf\u30f3\u30d1\u30af\u8cea\u767a\u73fe\u5b9f\u9a13\u306b\u306f\u767a\u73fe\u30d9\u30af\u30bf\u30fc\u304c\u6b20\u304b\u305b\u307e\u305b\u3093\u304c\u3001\u4e00\u304b\u3089\u4f5c\u308b\u3068\u306a\u308b\u3068\u3001\u304b\u306a\u308a\u306e\u624b\u9593\u3068\u7d4c\u9a13\u304c\u5fc5\u8981\u3067\u3059\u2026","rel":"","context":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","block_context":{"text":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/mol-bio\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/10\/protein-expression-cloning-bid-ts-mbr-25070_eyecatch.png?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/10\/protein-expression-cloning-bid-ts-mbr-25070_eyecatch.png?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/10\/protein-expression-cloning-bid-ts-mbr-25070_eyecatch.png?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/10\/protein-expression-cloning-bid-ts-mbr-25070_eyecatch.png?resize=700%2C400&ssl=1 2x"},"classes":[]},{"id":24187,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/ngs-gene-expression-csd-ts-ion-25073\/","url_meta":{"origin":7841,"position":1},"title":"\u3010\u3084\u3063\u3066\u307f\u305f\u3011\u5fae\u91cf\u30fb\u5206\u89e3RNA\u306b\u3088\u308b\u767a\u73fe\u89e3\u6790\u306e\u6700\u9069\u89e3\u306f\uff1fRNA-Seq\u3068Ion AmpliSeq Transcriptome\u3092\u6bd4\u3079\u3066\u307f\u305f","author":"LatB Staff","date":"2025\u5e7411\u670828\u65e5","format":false,"excerpt":"\u6b21\u4e16\u4ee3\u30b7\u30fc\u30b1\u30f3\u30b5\u3067\u306e\u767a\u73fe\u89e3\u6790\u306b\u53d6\u308a\u7d44\u3080\u969b\u3001RNA\u30b5\u30f3\u30d7\u30eb\u304c\u300c\u5c11\u306a\u3059\u304e\u308b\u300d\u300c\u5206\u89e3\u3057\u3066\u3044\u308b\u300d\u3068\u3044\u3046\u72b6\u6cc1\u306f\u2026","rel":"","context":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","block_context":{"text":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/mol-bio\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/11\/ngs-gene-expression-csd-ts-ion-25073_eyecatch-scaled.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/11\/ngs-gene-expression-csd-ts-ion-25073_eyecatch-scaled.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/11\/ngs-gene-expression-csd-ts-ion-25073_eyecatch-scaled.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/11\/ngs-gene-expression-csd-ts-ion-25073_eyecatch-scaled.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/11\/ngs-gene-expression-csd-ts-ion-25073_eyecatch-scaled.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/11\/ngs-gene-expression-csd-ts-ion-25073_eyecatch-scaled.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":23239,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/ngs-gene-expression-csd-ts-bfx-25060\/","url_meta":{"origin":7841,"position":2},"title":"\u98df\u54c1\u958b\u767a\u306b\u304a\u3051\u308b\u83cc\u53e2\u89e3\u6790\u3068\u907a\u4f1d\u5b50\u767a\u73fe\u89e3\u6790\u306e\u6d3b\u7528","author":"LatB Staff","date":"2025\u5e7410\u67088\u65e5","format":false,"excerpt":"\u907a\u4f1d\u5b50\u95a2\u9023\u306e\u89e3\u6790\u6280\u8853\u304c\u7814\u7a76\u306e\u307f\u306a\u3089\u305a\u7523\u696d\u5206\u91ce\u3067\u6d3b\u7528\u3055\u308c\u308b\u3088\u3046\u306b\u306a\u308a\u3001\u5e74\u6708\u304c\u7d4c\u904e\u3059\u308b\u306b\u3064\u308c\u3066\u5fdc\u7528\u7bc4\u56f2\u3082\u2026","rel":"","context":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","block_context":{"text":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/mol-bio\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/09\/ngs-gene-expression-gsd-ts-tr-25060_eyecatch.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/09\/ngs-gene-expression-gsd-ts-tr-25060_eyecatch.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/09\/ngs-gene-expression-gsd-ts-tr-25060_eyecatch.jpg?resize=525%2C300&ssl=1 1.5x"},"classes":[]},{"id":23665,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/pcr-dna-gsd-ts-tr-25064\/","url_meta":{"origin":7841,"position":3},"title":"\u3010\u3084\u3063\u3066\u307f\u305f\u3011PCR\u306e\u30a2\u30cb\u30fc\u30ea\u30f3\u30b0\u6e29\u5ea6\u3092\u601d\u3044\u5207\u308a\u632f\u3063\u3066\u307f\u305f","author":"LatB Staff","date":"2025\u5e7410\u670828\u65e5","format":false,"excerpt":"\u65b0\u305f\u306aPCR\u691c\u51fa\u7cfb\u3092\u69cb\u7bc9\u3059\u308b\u5834\u5408\u3001\u4f55\u3088\u308a\u3082\u30d7\u30e9\u30a4\u30de\u30fc\u306e\u914d\u5217\u304c\u91cd\u8981\u3068\u3044\u3046\u3053\u3068\u306f\u591a\u304f\u306e\u65b9\u304c\u8a8d\u8b58\u3057\u3066\u3044\u308b\u306e\u2026","rel":"","context":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","block_context":{"text":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/mol-bio\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/10\/pcr-dna-gsd-ts-tr-25064_eyecatch-scaled.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/10\/pcr-dna-gsd-ts-tr-25064_eyecatch-scaled.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/10\/pcr-dna-gsd-ts-tr-25064_eyecatch-scaled.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/10\/pcr-dna-gsd-ts-tr-25064_eyecatch-scaled.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/10\/pcr-dna-gsd-ts-tr-25064_eyecatch-scaled.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/10\/pcr-dna-gsd-ts-tr-25064_eyecatch-scaled.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":24606,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/transfection-antibody-bid-ts-mbr-26004\/","url_meta":{"origin":7841,"position":4},"title":"\u7d30\u80de\u5185\u30bf\u30f3\u30d1\u30af\u8cea\u9664\u53bb\u30b7\u30b9\u30c6\u30e0\uff08Trim-Away\u6cd5\uff09\u306e\u7d39\u4ecb\uff5e\u30a8\u30ec\u30af\u30c8\u30ed\u30dd\u30ec\u30fc\u30b7\u30e7\u30f3\u6a5f\u5668\u3092\u4f7f\u7528\u3057\u3066\uff5e","author":"LatB Staff","date":"2026\u5e742\u67084\u65e5","format":false,"excerpt":"2018\u5e74\u306e\u6587\u732e(1)\u3067\u7d30\u80de\u5185\u306e\u5185\u5728\u6027\u30bf\u30f3\u30d1\u30af\u8cea\u3092\u76f4\u63a5\u5206\u89e3\u3059\u308b\u3001Trim-Away\u6cd5\u304c\u7d39\u4ecb\u3055\u308c\u307e\u3057\u305f\u2026","rel":"","context":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","block_context":{"text":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/mol-bio\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/01\/transfection-antibody-bid-ts-mbr-26004_eyecatch.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/01\/transfection-antibody-bid-ts-mbr-26004_eyecatch.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/01\/transfection-antibody-bid-ts-mbr-26004_eyecatch.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/01\/transfection-antibody-bid-ts-mbr-26004_eyecatch.jpg?resize=700%2C400&ssl=1 2x"},"classes":[]},{"id":20152,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/exosome-nucleic-acid-purification-ts-r-25017\/","url_meta":{"origin":7841,"position":5},"title":"\u3010\u7b2c3\u56de\u3011\u201cRNA cargo\u201d\u306e\u7cbe\u88fd\u3068\u5b9a\u91cf\u89e3\u6790","author":"LatB Staff","date":"2026\u5e745\u670813\u65e5","format":false,"excerpt":"\u7b2c2\u56de\u3067\u306f\u3001\u57f9\u990a\u4e0a\u6e05\u3084\u3055\u307e\u3056\u307e\u306a\u4f53\u6db2\u30b5\u30f3\u30d7\u30eb\u304b\u3089\u306e\u30a8\u30af\u30bd\u30bd\u30fc\u30e0\u306e\u6fc3\u7e2e\u30fb\u56de\u53ce\u65b9\u6cd5\u306b\u3064\u3044\u3066\u7d39\u4ecb\u3057\u307e\u3057\u305f\u304c\u2026","rel":"","context":"\u305d\u306e\u4ed6","block_context":{"text":"\u305d\u306e\u4ed6","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/else\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/f17931341a23d82235760ed66ded9c41.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/f17931341a23d82235760ed66ded9c41.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/f17931341a23d82235760ed66ded9c41.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/f17931341a23d82235760ed66ded9c41.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/f17931341a23d82235760ed66ded9c41.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/f17931341a23d82235760ed66ded9c41.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]}],"jetpack_sharing_enabled":true,"amp_enabled":true,"jetpack_featured_media_url":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2020\/10\/shutterstock_1483033733-scaled.jpg","_links":{"self":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/posts\/7841","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/users\/975"}],"replies":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/comments?post=7841"}],"version-history":[{"count":0,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/posts\/7841\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/media\/10134"}],"wp:attachment":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/media?parent=7841"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/categories?post=7841"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/tags?post=7841"},{"taxonomy":"division","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/division?post=7841"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}