{"id":798,"date":"2017-05-19T00:00:00","date_gmt":"2017-05-19T00:00:00","guid":{"rendered":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/how-securely-are-your-data-stored\/"},"modified":"2025-02-27T11:33:23","modified_gmt":"2025-02-27T02:33:23","slug":"how-securely-are-your-data-stored","status":"publish","type":"post","link":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/how-securely-are-your-data-stored\/","title":{"rendered":"\u30af\u30e9\u30a6\u30c9\u74b0\u5883\u3067\u306e\u7814\u7a76\u30c7\u30fc\u30bf\u306e\u4fdd\u7ba1\u306f\u30db\u30f3\u30c8\u306b\u5b89\u5168\uff1f"},"content":{"rendered":"<p>\u81ea\u5206\u306e\u7814\u7a76\u5ba4\u306e\u30b3\u30f3\u30d4\u30e5\u30fc\u30bf\u304b\u3089\u3001\u81ea\u5206\u306e\u7814\u7a76\u30c7\u30fc\u30bf\u3084\u6587\u66f8\u5316\u3055\u308c\u305f\u7814\u7a76\u6210\u679c\u304c\u524a\u9664\u3055\u308c\u305f\u308a\u76d7\u96e3\u3055\u308c\u308b\u3088\u3046\u306a\u61f8\u5ff5\u304c\u3042\u308b\u5834\u5408\u3001\u4f55\u3092\u3059\u3079\u304d\u3067\u3057\u3087\u3046\u304b\uff1f\u6b63\u89e3\u306f\u3001\u300c<strong>\u7814\u7a76\u5ba4\u306e\u30b3\u30f3\u30d4\u30e5\u30fc\u30bf\u306b1\u30b3\u30d4\u30fc\u3001\u81ea\u5b85\u306e\u30b3\u30f3\u30d4\u30e5\u30fc\u30bf\u306b1\u30b3\u30d4\u30fc\u3001\u8857\u306e\u4e2d\u309224\u6642\u9593\u3001\u90317\u65e5\u9593\u8d70\u3063\u3066\u3044\u308b\u88c5\u7532\u8eca\u306e\u4e2d\u306b1\u30b3\u30d4\u30fc\u4fdd\u5b58\u3059\u308b<\/strong>\u300d\u3067\u3059\u3002\u3053\u308c\u3067\u90fd\u5e02\u30ec\u30d9\u30eb\u306e\u5927\u707d\u5bb3\u304c\u3042\u3063\u3066\u3082\u7814\u7a76\u30c7\u30fc\u30bf\u304c\u4fdd\u8b77\u3055\u308c\u308b\u306f\u305a\u3067\u3059\u3002\u3082\u3061\u308d\u3093\u3001\u88c5\u7532\u8eca\u306e\u4e2d\u306b\u30c7\u30fc\u30bf\u3092\u4fdd\u7ba1\u3059\u308b\u3053\u3068\u306f\u96e3\u3057\u3044\u3067\u3059\u304c\u3001\u30c7\u30fc\u30bf\u3092\u5b89\u5168\u304b\u3064\u78ba\u5b9f\u306b\u4fdd\u5b58\u3059\u308b\u5fc5\u8981\u304c\u3042\u308a\u307e\u3059\u3002\u73fe\u5728\u306f\u3001<strong><a href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/digital-solutions.html?CID=cdi_cbu_sbu_r04_jp_cp0000_pjt0000_bid00000_0so_blg_op_awa_oc_s00_digi3_Social_LAB\" target=\"_blank\" rel=\"noopener noreferrer\">Thermo Fisher Connect<\/a>\u306e\u3088\u3046\u306a\u30af\u30e9\u30a6\u30c9\u30bd\u30ea\u30e5\u30fc\u30b7\u30e7\u30f3\u304c\u3042\u308b\u305f\u3081\u3001\u7814\u7a76\u30c7\u30fc\u30bf\u3092\u3069\u3053\u306b\u4fdd\u5b58\u3059\u308b\u304b\u306b\u3064\u3044\u3066\u306f\u5fc3\u914d\u3059\u308b\u5fc5\u8981\u306f\u3042\u308a\u307e\u305b\u3093\u3002<\/strong><\/p>\n<p><a href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/digital-solutions.html?CID=cdi_cbu_sbu_r04_jp_cp0000_pjt0000_bid00000_0so_blg_op_awa_oc_s00_digi3_Social_LAB\" target=\"_blank\" rel=\"noopener noreferrer\">Thermo Fisher Connect<\/a>\u306f\u3001\u9769\u65b0\u7684\u306a\u7814\u7a76\u8005\u306b\u306a\u308b\u305f\u3081\u306e\u5168\u304f\u65b0\u3057\u3044\u65b9\u6cd5\u3067\u3059\u3002\u4e00\u8a00\u3067\u8aac\u660e\u3059\u308b\u3068\u3001\u300c<strong>\u3059\u3079\u3066\u304c\u63a5\u7d9a\u3055\u308c\u3066\u3044\u308b<\/strong>\u300d\u3068\u3044\u3046\u3053\u3068\u3067\u3059\u3002<a href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/digital-solutions.html?CID=cdi_cbu_sbu_r04_jp_cp0000_pjt0000_bid00000_0so_blg_op_awa_oc_s00_digi3_Social_LAB\" target=\"_blank\" rel=\"noopener noreferrer\">Thermo Fisher Connect<\/a>\u306b\u3088\u308a\u3001<strong>\u89e3\u6790\u30c7\u30fc\u30bf\u30d5\u30a1\u30a4\u30eb\u306e\u81ea\u52d5\u30a2\u30c3\u30d7\u30ed\u30fc\u30c9<\/strong>\u3084<strong>\u4fdd\u7ba1<\/strong>\u3001\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u6a5f\u5668\u306a\u3069\u306e<strong>\u30ea\u30e2\u30fc\u30c8\u30e2\u30cb\u30bf\u30ea\u30f3\u30b0<\/strong>\u3001<strong>\u9ad8\u901f\u306a\u30c7\u30fc\u30bf\u89e3\u6790<\/strong>\u3001\u30d7\u30ed\u30b8\u30a7\u30af\u30c8\u30d5\u30a9\u30eb\u30c0\u3068\u30c7\u30fc\u30bf\u30bb\u30c3\u30c8\u306e<strong>\u5171\u540c\u7814\u7a76\u8005\u3068\u306e\u5b89\u5168\u306a\u5171\u6709<\/strong>\u304c\u53ef\u80fd\u3067\u3059\u3002\u8a73\u7d30\u306b\u3064\u3044\u3066\u306f\u4e0b\u8a18\u306e\u8a18\u4e8b\u3092\u3054\u89a7\u304f\u3060\u3055\u3044\u3002<br \/>\n<a href=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/5-ways-connecting-with-the-cloud-can-help-save-time-in-the-lab\/?CID=cdi_cbu_sbu_r04_jp_cp0000_pjt0000_bid00000_0so_blg_op_awa_oc_s00_digi3_Social_LAB\" target=\"_blank\" rel=\"noopener\">\u6642\u9593\u7bc0\u7d04\uff01\u7814\u7a76\u5ba4\u3067\u30af\u30e9\u30a6\u30c9\u74b0\u5883\u3092\u4f7f\u7528\u3059\u308b\u3079\u304d5\u3064\u306e\u30e1\u30ea\u30c3\u30c8\u3068\u306f\uff1f \u00bb<\/a><\/p>\n<p><a href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/digital-solutions.html?CID=cdi_cbu_sbu_r04_jp_cp0000_pjt0000_bid00000_0so_blg_op_awa_oc_s00_digi3_Social_LAB\" target=\"_blank\" rel=\"noopener noreferrer\">Thermo Fisher Connect<\/a>\u3092\u4f7f\u7528\u3059\u308b\u3068\u3001\u89e3\u6790\u88c5\u7f6e\u3084\u7814\u7a76\u5ba4\u306e\u30ed\u30fc\u30ab\u30eb\u306b\u3042\u308b\u30b3\u30f3\u30d4\u30e5\u30fc\u30bf\u306e\u30c7\u30fc\u30bf\u3060\u3051\u3067\u306a\u304f\u3001<strong>\u753b\u50cf\u30d5\u30a1\u30a4\u30eb\u3001\u30d7\u30ec\u30bc\u30f3\u30c6\u30fc\u30b7\u30e7\u30f3\u30b9\u30e9\u30a4\u30c9\u3001PDF\u30d5\u30a1\u30a4\u30eb\u3001\u305d\u306e\u4ed6\u306e\u91cd\u8981\u306a\u6587\u732e\u3092\u5b89\u5168\u306b\u4fdd\u5b58\u3059\u308b\u305f\u3081\u306b\u30a2\u30c3\u30d7\u30ed\u30fc\u30c9\u3067\u304d\u307e\u3059\u3002<\/strong>\u30d5\u30a1\u30a4\u30eb\u304c\u4fdd\u5b58\u3055\u308c\u305f\u3089\u3001\u30d5\u30a9\u30eb\u30c0\u3092\u4f5c\u6210\u3057\u3066\u7ba1\u7406\u3057\u3001\u305d\u306e\u30d5\u30a1\u30a4\u30eb\u3092\u7814\u7a76\u5ba4\u306e\u4ed6\u306e\u7814\u7a76\u8005\u307e\u305f\u306f\u4e16\u754c\u4e2d\u306e\u4ed6\u306e\u7814\u7a76\u8005\u3068\u5171\u6709\u3067\u304d\u307e\u3059\u3002<\/p>\n<p><strong>\u30c7\u30fc\u30bf\u306e\u5206\u6790\u3068\u4fdd\u5b58\u306b\u52a0\u3048\u3066\u3001\u5f0a\u793e\u306f\u30c7\u30fc\u30bf\u30bb\u30ad\u30e5\u30ea\u30c6\u30a3\u3001\u30c7\u30fc\u30bf\u4fdd\u8b77\u3001\u30c7\u30fc\u30bf\u30d7\u30e9\u30a4\u30d0\u30b7\u30fc\u3092\u975e\u5e38\u306b\u91cd\u8981\u306a\u3082\u306e\u3068\u3057\u3066\u3044\u307e\u3059\u3002<\/strong>\u5f0a\u793e\u306f\u3001\u30af\u30e9\u30a6\u30c9\u74b0\u5883\u3067\u30c7\u30fc\u30bf\u3092\u78ba\u5b9f\u306b\u4fdd\u8b77\u3059\u308b\u305f\u3081\u306b\u3001\u3044\u304f\u3064\u304b\u306e\u6a19\u6e96\u3068\u30dd\u30ea\u30b7\u30fc\u3092\u5b9f\u88c5\u3057\u3066\u3044\u307e\u3059\u3002\u305f\u3068\u3048\u3070\u3001\u30af\u30e9\u30a6\u30c9\u30d7\u30e9\u30c3\u30c8\u30d5\u30a9\u30fc\u30e0\u30c6\u30af\u30ce\u30ed\u30b8\u30fc\u306e\u30ea\u30fc\u30c0\u30fc\u3067\u3042\u308bAmazon Web Services\uff08AWS\uff09\u304c\u3001\u5f0a\u793e\u306e\u30a4\u30f3\u30d5\u30e9\u30b9\u30c8\u30e9\u30af\u30c1\u30e3\u30d1\u30fc\u30c8\u30ca\u30fc\u3068\u3057\u3066\u9078\u3070\u308c\u307e\u3057\u305f\u3002\uff08AWS\u30c7\u30fc\u30bf\u30bb\u30f3\u30bf\u30fc\u306f\u6700\u9ad8\u6c34\u6e96\u306eSSAE 16\u8a8d\u8a3c\u3092\u53d6\u5f97\u3057\u3001Service Organization Control 1\uff08SOC1\u00ae\uff09\u30ec\u30dd\u30fc\u30c8\u3092\u516c\u958b\u3057\u3066\u3044\u307e\u3059\uff09\u3002<\/p>\n<p>\u3053\u306e\u30bf\u30a4\u30d7\u306e\u30bb\u30ad\u30e5\u30ea\u30c6\u30a3\u3068\u305d\u306e\u4ed6\u306e\u30b7\u30b9\u30c6\u30e0\u30b3\u30f3\u30c8\u30ed\u30fc\u30eb\u3092\u4f7f\u7528\u3059\u308b\u3053\u3068\u3067\u3001<a href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/digital-solutions.html?CID=cdi_cbu_sbu_r04_jp_cp0000_pjt0000_bid00000_0so_blg_op_awa_oc_s00_digi3_Social_LAB\" target=\"_blank\" rel=\"noopener noreferrer\">Thermo Fisher Connect<\/a>\u306f\u30e6\u30fc\u30b6\u30fc\u30c7\u30fc\u30bf\u3092\u5206\u96e2\u3057\u3001\u30c7\u30fc\u30bf\u6240\u6709\u8005\u306e\u307f\u306b\u30a2\u30af\u30bb\u30b9\u3092\u5236\u9650\u3057\u3001\u30c7\u30fc\u30bf\u6240\u6709\u8005\u304c\u5171\u6709\u3057\u306a\u3044\u9650\u308a\u3001\u4ed6\u306e\u30e6\u30fc\u30b6\u30fc\u306f\u305d\u306e\u30c7\u30fc\u30bf\u3092\u898b\u308b\u3053\u3068\u304c\u3067\u304d\u307e\u305b\u3093\u3002\u30ed\u30fc\u30ab\u30eb\u306b\u3042\u308b\u30b3\u30f3\u30d4\u30e5\u30fc\u30bf\u307e\u305f\u306f\u89e3\u6790\u88c5\u7f6e\u304b\u3089<a href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/digital-solutions.html?CID=cdi_cbu_sbu_r04_jp_cp0000_pjt0000_bid00000_0so_blg_op_awa_oc_s00_digi3_Social_LAB\" target=\"_blank\" rel=\"noopener noreferrer\">Thermo Fisher Connect<\/a>\u306b\u30c7\u30fc\u30bf\u304c\u30a2\u30c3\u30d7\u30ed\u30fc\u30c9\u3055\u308c\u308b\u3068\u3001\u30c7\u30fc\u30bf\u306f\u30a6\u30a7\u30d6\u4e0a\u306e\u30af\u30ec\u30b8\u30c3\u30c8\u30ab\u30fc\u30c9\u53d6\u5f15\u3068\u540c\u3058\u30bf\u30a4\u30d7\u306e\u6280\u8853\u3092\u4f7f\u7528\u3057\u3066\u6697\u53f7\u5316\u3055\u308c\u307e\u3059\u3002\u307e\u305f\u3001\u30a2\u30c3\u30d7\u30ed\u30fc\u30c9\u5f8c\u3001\u30c7\u30fc\u30bf\u304c\u4fdd\u5b58\u3055\u308c\u308b\u969b\u306b\u3082\u6697\u53f7\u5316\u30b9\u30c6\u30c3\u30d7\u304c\u518d\u5ea6\u4f7f\u7528\u3055\u308c\u307e\u3059\u3002<strong>\u5f0a\u793e\u306e\u30e9\u30dc\u88c5\u7f6e\u3084\u89e3\u6790\u88c5\u7f6e\u306e\u591a\u304f\u306f\u3001\u30a4\u30f3\u30bf\u30fc\u30cd\u30c3\u30c8\u306b\u63a5\u7d9a\u3055\u308c\u3066\u3044\u308b\u306e\u3067\u3001<a href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/digital-solutions.html?CID=cdi_cbu_sbu_r04_jp_cp0000_pjt0000_bid00000_0so_blg_op_awa_oc_s00_digi3_Social_LAB\" target=\"_blank\" rel=\"noopener noreferrer\">Thermo Fisher Connect<\/a>\u3092\u4f7f\u7528\u3059\u308b\u3053\u3068\u3067\u3001\u3044\u3064\u3067\u3082\u3001\u3069\u3053\u3067\u3082\u3001\u305d\u306e\u89e3\u6790\u30c7\u30fc\u30bf\u3084\u89e3\u6790\u88c5\u7f6e\u306b\u63a5\u7d9a\u3067\u304d\u307e\u3059\u3002<\/strong><\/p>\n<p><a href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/digital-solutions.html?CID=cdi_cbu_sbu_r04_jp_cp0000_pjt0000_bid00000_0so_blg_op_awa_oc_s00_digi3_Social_LAB\" target=\"_blank\" rel=\"noopener noreferrer\">Thermo Fisher Connect<\/a>\u3092\u7814\u7a76\u5ba4\u3067\u4f7f\u7528\u3059\u308b\u3053\u3068\u306f\u3001<strong>\u6700\u5148\u7aef\u306e\u7814\u7a76\u3092\u30b5\u30dd\u30fc\u30c8\u3059\u308b\u753b\u671f\u7684\u306a\u65b9\u6cd5\u3067\u3042\u308a\u3001\u6bce\u65e5\u306e\u5b9f\u9a13\u30ef\u30fc\u30af\u30d5\u30ed\u30fc\u306b\u304a\u3044\u3066\u7d71\u5408\u3055\u308c\u305f\u79d1\u5b66\u7684\u30c4\u30fc\u30eb<\/strong>\u3067\u3059\u3002\u5b9f\u9a13\u3092\u8a08\u753b\u3059\u308b\u3053\u3068\u304b\u3089\u3001\u89e3\u6790\u88c5\u7f6e\u3092\u76e3\u8996\u3057\u3001\u7d50\u679c\u3092\u5206\u6790\u3059\u308b\u3068\u3053\u308d\u307e\u3067\u3001\u5b9f\u9a13\u30c7\u30fc\u30bf\u304c\u30af\u30e9\u30a6\u30c9\u74b0\u5883\u3067\u5b89\u5168\u306b\u4fdd\u7ba1\u3055\u308c\u3066\u3044\u308b\u3053\u3068\u3084\u5f0a\u793e\u306f\u7814\u7a76\u5168\u4f53\u3092\u901a\u3058\u3066\u4fe1\u983c\u3067\u304d\u308b\u30d1\u30fc\u30c8\u30ca\u30fc\u3067\u3042\u308b\u3053\u3068\u304c\u78ba\u4fe1\u3067\u304d\u308b\u3053\u3068\u3067\u3057\u3087\u3046\u3002<strong><a href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/digital-solutions.html?CID=cdi_cbu_sbu_r04_jp_cp0000_pjt0000_bid00000_0so_blg_op_awa_oc_s00_digi3_Social_LAB\" target=\"_blank\" rel=\"noopener noreferrer\">Thermo Fisher Connect<\/a>\u3067\u7814\u7a76\u30c7\u30fc\u30bf\u3092\u4fdd\u5b58\u3059\u308b\u3053\u3068\u306f\u3001\u88c5\u7532\u8eca\u3092\u501f\u308a\u308b\u3088\u308a\u306f\u308b\u304b\u306b\u7c21\u5358\u3067\u3059\uff01<\/strong><\/p>\n<p>&nbsp;<\/p>\n<p>\u7814\u7a76\u7528\u306b\u306e\u307f\u4f7f\u7528\u3067\u304d\u307e\u3059\u3002\u8a3a\u65ad\u76ee\u7684\u304a\u3088\u3073\u305d\u306e\u624b\u7d9a\u304d\u4e0a\u3067\u306e\u4f7f\u7528\u306f\u3067\u304d\u307e\u305b\u3093\u3002<\/p>\n","protected":false},"excerpt":{"rendered":"<p>\u81ea\u5206\u306e\u7814\u7a76\u5ba4\u306e\u30b3\u30f3\u30d4\u30e5\u30fc\u30bf\u304b\u3089\u3001\u81ea\u5206\u306e\u7814\u7a76\u30c7\u30fc\u30bf\u3084\u6587\u66f8\u5316\u3055\u308c\u305f\u7814\u7a76\u6210\u679c\u304c\u524a\u9664\u3055\u308c\u305f\u308a\u76d7\u96e3\u3055\u308c\u308b\u3088\u3046\u306a\u61f8\u5ff5\u304c\u3042\u308b\u5834\u5408\u3001\u4f55\u3092\u3059\u3079\u304d\u3067\u3057\u3087\u3046\u304b\uff1fThermo Fihser Connect\u306e\u3088\u3046\u306a\u30af\u30e9\u30a6\u30c9\u30bd\u30ea\u30e5\u30fc\u30b7\u30e7\u30f3\u3092\u5229\u7528\u3059\u308c\u3070\u3001\u7814\u7a76\u30c7\u30fc\u30bf\u3092\u3069\u3053\u306b\u4fdd\u5b58\u3059\u308b\u304b\u306b\u3064\u3044\u3066\u306f\u5fc3\u914d\u3059\u308b\u5fc5\u8981\u306f\u3042\u308a\u307e\u305b\u3093\u3002<\/p>\n","protected":false},"author":988,"featured_media":3527,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_monsterinsights_skip_tracking":false,"_genesis_hide_title":false,"_genesis_hide_breadcrumbs":false,"_genesis_hide_singular_image":false,"_genesis_hide_footer_widgets":false,"_genesis_custom_body_class":"","_genesis_custom_post_class":"","_genesis_layout":"","_jetpack_newsletter_access":"","_jetpack_dont_email_post_to_subs":false,"_jetpack_newsletter_tier_id":0,"_jetpack_memberships_contains_paywalled_content":false,"_jetpack_feature_clip_id":0,"_jetpack_memberships_contains_paid_content":false,"footnotes":"","jetpack_post_was_ever_published":false},"categories":[155],"tags":[64],"division":[],"class_list":["post-798","post","type-post","status-publish","format-standard","has-post-thumbnail","category-else","tag-cloud","entry"],"_selected_authors":"","_selected_reviewers":"","acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v27.8 (Yoast SEO v27.8) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>\u30af\u30e9\u30a6\u30c9\u74b0\u5883\u3067\u306e\u7814\u7a76\u30c7\u30fc\u30bf\u306e\u4fdd\u7ba1\u306f\u30db\u30f3\u30c8\u306b\u5b89\u5168\uff1f - Learning at the Bench<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/how-securely-are-your-data-stored\/\" \/>\n<meta property=\"og:locale\" content=\"ja_JP\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"\u30af\u30e9\u30a6\u30c9\u74b0\u5883\u3067\u306e\u7814\u7a76\u30c7\u30fc\u30bf\u306e\u4fdd\u7ba1\u306f\u30db\u30f3\u30c8\u306b\u5b89\u5168\uff1f\" \/>\n<meta property=\"og:description\" content=\"\u81ea\u5206\u306e\u7814\u7a76\u5ba4\u306e\u30b3\u30f3\u30d4\u30e5\u30fc\u30bf\u304b\u3089\u3001\u81ea\u5206\u306e\u7814\u7a76\u30c7\u30fc\u30bf\u3084\u6587\u66f8\u5316\u3055\u308c\u305f\u7814\u7a76\u6210\u679c\u304c\u524a\u9664\u3055\u308c\u305f\u308a\u76d7\u96e3\u3055\u308c\u308b\u3088\u3046\u306a\u61f8\u5ff5\u304c\u3042\u308b\u5834\u5408\u3001\u4f55\u3092\u3059\u3079\u304d\u3067\u3057\u3087\u3046\u304b\uff1fThermo Fihser Connect\u306e\u3088\u3046\u306a\u30af\u30e9\u30a6\u30c9\u30bd\u30ea\u30e5\u30fc\u30b7\u30e7\u30f3\u3092\u5229\u7528\u3059\u308c\u3070\u3001\u7814\u7a76\u30c7\u30fc\u30bf\u3092\u3069\u3053\u306b\u4fdd\u5b58\u3059\u308b\u304b\u306b\u3064\u3044\u3066\u306f\u5fc3\u914d\u3059\u308b\u5fc5\u8981\u306f\u3042\u308a\u307e\u305b\u3093\u3002\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/how-securely-are-your-data-stored\/\" \/>\n<meta property=\"og:site_name\" content=\"Learning at the Bench\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/ThermoFisherJapan\" \/>\n<meta property=\"article:published_time\" content=\"2017-05-19T00:00:00+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2025-02-27T02:33:23+00:00\" \/>\n<meta property=\"og:image\" content=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/how-securely-are-your-data-stored-title.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"1200\" \/>\n\t<meta property=\"og:image:height\" content=\"630\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"LATB Staff\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:creator\" content=\"@ThermoFisherJP\" \/>\n<meta name=\"twitter:site\" content=\"@ThermoFisherJP\" \/>\n<meta name=\"twitter:label1\" content=\"\u57f7\u7b46\u8005\" \/>\n\t<meta name=\"twitter:data1\" content=\"LATB Staff\" \/>\n\t<meta name=\"twitter:label2\" content=\"\u63a8\u5b9a\u8aad\u307f\u53d6\u308a\u6642\u9593\" \/>\n\t<meta name=\"twitter:data2\" content=\"5\u5206\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/how-securely-are-your-data-stored\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/how-securely-are-your-data-stored\\\/\"},\"author\":{\"name\":\"LATB Staff\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#\\\/schema\\\/person\\\/201e6a5abb838fa34e8ff0174b015d36\"},\"headline\":\"\u30af\u30e9\u30a6\u30c9\u74b0\u5883\u3067\u306e\u7814\u7a76\u30c7\u30fc\u30bf\u306e\u4fdd\u7ba1\u306f\u30db\u30f3\u30c8\u306b\u5b89\u5168\uff1f\",\"datePublished\":\"2017-05-19T00:00:00+00:00\",\"dateModified\":\"2025-02-27T02:33:23+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/how-securely-are-your-data-stored\\\/\"},\"wordCount\":40,\"commentCount\":0,\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/how-securely-are-your-data-stored\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2019\\\/07\\\/how-securely-are-your-data-stored-title.jpg\",\"keywords\":[\"\u30af\u30e9\u30a6\u30c9\"],\"articleSection\":[\"\u305d\u306e\u4ed6\"],\"inLanguage\":\"ja\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/how-securely-are-your-data-stored\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/how-securely-are-your-data-stored\\\/\",\"url\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/how-securely-are-your-data-stored\\\/\",\"name\":\"\u30af\u30e9\u30a6\u30c9\u74b0\u5883\u3067\u306e\u7814\u7a76\u30c7\u30fc\u30bf\u306e\u4fdd\u7ba1\u306f\u30db\u30f3\u30c8\u306b\u5b89\u5168\uff1f - Learning at the Bench\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/how-securely-are-your-data-stored\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/how-securely-are-your-data-stored\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2019\\\/07\\\/how-securely-are-your-data-stored-title.jpg\",\"datePublished\":\"2017-05-19T00:00:00+00:00\",\"dateModified\":\"2025-02-27T02:33:23+00:00\",\"author\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#\\\/schema\\\/person\\\/201e6a5abb838fa34e8ff0174b015d36\"},\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/how-securely-are-your-data-stored\\\/#breadcrumb\"},\"inLanguage\":\"ja\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/how-securely-are-your-data-stored\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"ja\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/how-securely-are-your-data-stored\\\/#primaryimage\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2019\\\/07\\\/how-securely-are-your-data-stored-title.jpg\",\"contentUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2019\\\/07\\\/how-securely-are-your-data-stored-title.jpg\",\"width\":1200,\"height\":630,\"caption\":\"how-securely-are-your-data-stored-title\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/how-securely-are-your-data-stored\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"\u30af\u30e9\u30a6\u30c9\u74b0\u5883\u3067\u306e\u7814\u7a76\u30c7\u30fc\u30bf\u306e\u4fdd\u7ba1\u306f\u30db\u30f3\u30c8\u306b\u5b89\u5168\uff1f\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#website\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/\",\"name\":\"Learning at the Bench\",\"description\":\"\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"ja\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#\\\/schema\\\/person\\\/201e6a5abb838fa34e8ff0174b015d36\",\"name\":\"LATB Staff\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"ja\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/8803277856c8b753feb4217dff0f9953327452df1a615c3c88b2f9864efb2ddd?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/8803277856c8b753feb4217dff0f9953327452df1a615c3c88b2f9864efb2ddd?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/8803277856c8b753feb4217dff0f9953327452df1a615c3c88b2f9864efb2ddd?s=96&d=mm&r=g\",\"caption\":\"LATB Staff\"},\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/author\\\/latbstaff\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"\u30af\u30e9\u30a6\u30c9\u74b0\u5883\u3067\u306e\u7814\u7a76\u30c7\u30fc\u30bf\u306e\u4fdd\u7ba1\u306f\u30db\u30f3\u30c8\u306b\u5b89\u5168\uff1f - Learning at the Bench","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/how-securely-are-your-data-stored\/","og_locale":"ja_JP","og_type":"article","og_title":"\u30af\u30e9\u30a6\u30c9\u74b0\u5883\u3067\u306e\u7814\u7a76\u30c7\u30fc\u30bf\u306e\u4fdd\u7ba1\u306f\u30db\u30f3\u30c8\u306b\u5b89\u5168\uff1f","og_description":"\u81ea\u5206\u306e\u7814\u7a76\u5ba4\u306e\u30b3\u30f3\u30d4\u30e5\u30fc\u30bf\u304b\u3089\u3001\u81ea\u5206\u306e\u7814\u7a76\u30c7\u30fc\u30bf\u3084\u6587\u66f8\u5316\u3055\u308c\u305f\u7814\u7a76\u6210\u679c\u304c\u524a\u9664\u3055\u308c\u305f\u308a\u76d7\u96e3\u3055\u308c\u308b\u3088\u3046\u306a\u61f8\u5ff5\u304c\u3042\u308b\u5834\u5408\u3001\u4f55\u3092\u3059\u3079\u304d\u3067\u3057\u3087\u3046\u304b\uff1fThermo Fihser Connect\u306e\u3088\u3046\u306a\u30af\u30e9\u30a6\u30c9\u30bd\u30ea\u30e5\u30fc\u30b7\u30e7\u30f3\u3092\u5229\u7528\u3059\u308c\u3070\u3001\u7814\u7a76\u30c7\u30fc\u30bf\u3092\u3069\u3053\u306b\u4fdd\u5b58\u3059\u308b\u304b\u306b\u3064\u3044\u3066\u306f\u5fc3\u914d\u3059\u308b\u5fc5\u8981\u306f\u3042\u308a\u307e\u305b\u3093\u3002","og_url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/how-securely-are-your-data-stored\/","og_site_name":"Learning at the Bench","article_publisher":"https:\/\/www.facebook.com\/ThermoFisherJapan","article_published_time":"2017-05-19T00:00:00+00:00","article_modified_time":"2025-02-27T02:33:23+00:00","og_image":[{"width":1200,"height":630,"url":"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/how-securely-are-your-data-stored-title.jpg","type":"image\/jpeg"}],"author":"LATB Staff","twitter_card":"summary_large_image","twitter_creator":"@ThermoFisherJP","twitter_site":"@ThermoFisherJP","twitter_misc":{"\u57f7\u7b46\u8005":"LATB Staff","\u63a8\u5b9a\u8aad\u307f\u53d6\u308a\u6642\u9593":"5\u5206"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/how-securely-are-your-data-stored\/#article","isPartOf":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/how-securely-are-your-data-stored\/"},"author":{"name":"LATB Staff","@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#\/schema\/person\/201e6a5abb838fa34e8ff0174b015d36"},"headline":"\u30af\u30e9\u30a6\u30c9\u74b0\u5883\u3067\u306e\u7814\u7a76\u30c7\u30fc\u30bf\u306e\u4fdd\u7ba1\u306f\u30db\u30f3\u30c8\u306b\u5b89\u5168\uff1f","datePublished":"2017-05-19T00:00:00+00:00","dateModified":"2025-02-27T02:33:23+00:00","mainEntityOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/how-securely-are-your-data-stored\/"},"wordCount":40,"commentCount":0,"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/how-securely-are-your-data-stored\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/how-securely-are-your-data-stored-title.jpg","keywords":["\u30af\u30e9\u30a6\u30c9"],"articleSection":["\u305d\u306e\u4ed6"],"inLanguage":"ja","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/how-securely-are-your-data-stored\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/how-securely-are-your-data-stored\/","url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/how-securely-are-your-data-stored\/","name":"\u30af\u30e9\u30a6\u30c9\u74b0\u5883\u3067\u306e\u7814\u7a76\u30c7\u30fc\u30bf\u306e\u4fdd\u7ba1\u306f\u30db\u30f3\u30c8\u306b\u5b89\u5168\uff1f - Learning at the Bench","isPartOf":{"@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/how-securely-are-your-data-stored\/#primaryimage"},"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/how-securely-are-your-data-stored\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/how-securely-are-your-data-stored-title.jpg","datePublished":"2017-05-19T00:00:00+00:00","dateModified":"2025-02-27T02:33:23+00:00","author":{"@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#\/schema\/person\/201e6a5abb838fa34e8ff0174b015d36"},"breadcrumb":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/how-securely-are-your-data-stored\/#breadcrumb"},"inLanguage":"ja","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/how-securely-are-your-data-stored\/"]}]},{"@type":"ImageObject","inLanguage":"ja","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/how-securely-are-your-data-stored\/#primaryimage","url":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/how-securely-are-your-data-stored-title.jpg","contentUrl":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/how-securely-are-your-data-stored-title.jpg","width":1200,"height":630,"caption":"how-securely-are-your-data-stored-title"},{"@type":"BreadcrumbList","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/how-securely-are-your-data-stored\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/"},{"@type":"ListItem","position":2,"name":"\u30af\u30e9\u30a6\u30c9\u74b0\u5883\u3067\u306e\u7814\u7a76\u30c7\u30fc\u30bf\u306e\u4fdd\u7ba1\u306f\u30db\u30f3\u30c8\u306b\u5b89\u5168\uff1f"}]},{"@type":"WebSite","@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#website","url":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/","name":"Learning at the Bench","description":"","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"ja"},{"@type":"Person","@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#\/schema\/person\/201e6a5abb838fa34e8ff0174b015d36","name":"LATB Staff","image":{"@type":"ImageObject","inLanguage":"ja","@id":"https:\/\/secure.gravatar.com\/avatar\/8803277856c8b753feb4217dff0f9953327452df1a615c3c88b2f9864efb2ddd?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/8803277856c8b753feb4217dff0f9953327452df1a615c3c88b2f9864efb2ddd?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/8803277856c8b753feb4217dff0f9953327452df1a615c3c88b2f9864efb2ddd?s=96&d=mm&r=g","caption":"LATB Staff"},"url":"https:\/\/admin.acceleratingscience.com\/author\/latbstaff\/"}]}},"taxonomy_info":{"category":[{"value":155,"label":"\u305d\u306e\u4ed6"}],"post_tag":[{"value":64,"label":"\u30af\u30e9\u30a6\u30c9"}]},"featured_image_src_large":["https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/how-securely-are-your-data-stored-title-1024x538.jpg",760,399,true],"author_info":{"display_name":"LATB Staff","author_link":"https:\/\/admin.acceleratingscience.com\/author\/latbstaff\/"},"comment_info":0,"category_info":[{"term_id":155,"name":"\u305d\u306e\u4ed6","slug":"else","term_group":0,"term_taxonomy_id":155,"taxonomy":"category","description":"","parent":0,"count":63,"filter":"raw","meta":[],"cat_ID":155,"category_count":63,"category_description":"","cat_name":"\u305d\u306e\u4ed6","category_nicename":"else","category_parent":0}],"tag_info":[{"term_id":64,"name":"\u30af\u30e9\u30a6\u30c9","slug":"cloud","term_group":0,"term_taxonomy_id":64,"taxonomy":"post_tag","description":"","parent":0,"count":3,"filter":"raw","meta":[]}],"jetpack-related-posts":[{"id":25016,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/battery-development-battery-manufacturing-csm-26014\/","url_meta":{"origin":798,"position":0},"title":"Fraunhofer FFB\u306e\u96fb\u6c60\u30a4\u30ce\u30d9\u30fc\u30b7\u30e7\u30f3\u30cf\u30d6\u3000\u7814\u7a76\u3068\u7523\u696d\u3092\u3064\u306a\u3050\u67b6\u3051\u6a4b","author":"LatB Staff","date":"2026\u5e743\u670830\u65e5","format":false,"excerpt":"\u30bf\u30a4\u30c8\u30eb Fraunhofer FFB\u306e\u96fb\u6c60\u30a4\u30ce\u30d9\u30fc\u30b7\u30e7\u30f3\u30cf\u30d6\u3000\u7814\u7a76\u3068\u7523\u696d\u3092\u3064\u306a\u3050\u67b6\u3051\u6a4b\u6b27\u5dde\u306b\u304a\u3051\u308b\u2026","rel":"","context":"\u5206\u6790\u30fb\u6e2c\u5b9a\u95a2\u9023","block_context":{"text":"\u5206\u6790\u30fb\u6e2c\u5b9a\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/analysis\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/03\/battery-development-battery-manufacturing-csm-26014_eyecatch.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/03\/battery-development-battery-manufacturing-csm-26014_eyecatch.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/03\/battery-development-battery-manufacturing-csm-26014_eyecatch.jpg?resize=525%2C300&ssl=1 1.5x"},"classes":[]},{"id":24953,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/ngs-gene-expression-csd-ts-ion-26011\/","url_meta":{"origin":798,"position":1},"title":"\u30e9\u30a4\u30d6\u30e9\u30ea\u30fc\u8abf\u88fd\u306e\u81ea\u52d5\u5316\u3067NGS\u306e\u53ef\u80fd\u6027\u3092\u5e83\u3052\u308b\u2015Ion Chef\u30b7\u30b9\u30c6\u30e0\u304c\u5909\u3048\u308b\u7814\u7a76\u5ba4\u306e\u30ef\u30fc\u30af\u30d5\u30ed\u30fc","author":"LatB Staff","date":"2026\u5e744\u670810\u65e5","format":false,"excerpt":"\u524d\u51e6\u7406\u306e\u81ea\u52d5\u5316\u304c\u3001NGS\u306e\u65b0\u3057\u3044\u6a19\u6e96\u3092\u3064\u304f\u308b\u6b21\u4e16\u4ee3\u30b7\u30fc\u30b1\u30f3\u30b7\u30f3\u30b0\uff08NGS\uff09\u304c\u65e5\u5e38\u7684\u306a\u7814\u7a76\u30c4\u30fc\u30eb\u3068\u306a\u3063\u2026","rel":"","context":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","block_context":{"text":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/mol-bio\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/02\/ngs-gene-expression-csd-ts-ion-26011_eyecatch.jpeg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/02\/ngs-gene-expression-csd-ts-ion-26011_eyecatch.jpeg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/02\/ngs-gene-expression-csd-ts-ion-26011_eyecatch.jpeg?resize=525%2C300&ssl=1 1.5x"},"classes":[]},{"id":24495,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/laboratory-nalgene-lpd-25076\/","url_meta":{"origin":798,"position":2},"title":"\u30e9\u30dc\u30dc\u30c8\u30eb\u306f\u3059\u3054\u3044\uff01\uff5e\u30e9\u30dc\u3067\u4f7f\u3046\u30dc\u30c8\u30eb\u306e\u79d8\u5bc6\u3092\u63a2\u308b\uff5e","author":"LatB Staff","date":"2025\u5e7412\u670824\u65e5","format":false,"excerpt":"\u65e5\u5e38\u751f\u6d3b\u3067\u4f7f\u3046\u30dc\u30c8\u30eb\u3068\u3001\u30e9\u30dc\u3067\u4f7f\u3046\u30dc\u30c8\u30eb\u3068\u3067\u306f\u4f55\u304c\u9055\u3046\u306e\u3067\u3057\u3087\u3046\u304b\uff1f\u4e00\u822c\u7684\u306a\u30dc\u30c8\u30eb\u3068\u30e9\u30dc\u30dc\u30c8\u30eb\u3068\u306e\u9055\u2026","rel":"","context":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","block_context":{"text":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/mol-bio\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/12\/laboratory-nalgene-lpd-25076_eyecatch-scaled.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/12\/laboratory-nalgene-lpd-25076_eyecatch-scaled.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/12\/laboratory-nalgene-lpd-25076_eyecatch-scaled.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/12\/laboratory-nalgene-lpd-25076_eyecatch-scaled.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/12\/laboratory-nalgene-lpd-25076_eyecatch-scaled.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/12\/laboratory-nalgene-lpd-25076_eyecatch-scaled.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":24462,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/battery-development-microscopy-csm-25076\/","url_meta":{"origin":798,"position":3},"title":"\u5168\u56fa\u4f53\u96fb\u6c60\u306e\u9769\u65b0\u3092\u652f\u3048\u308b\u5148\u7aef\u7684\u7279\u6027\u8a55\u4fa1\u6280\u8853\u306e\u63a2\u7a76","author":"LatB Staff","date":"2025\u5e7412\u670817\u65e5","format":false,"excerpt":"\u5168\u56fa\u4f53\u96fb\u6c60\u306e\u958b\u767a\u3067\u306f\u3001\u4f7f\u7528\u3055\u308c\u308b\u6750\u6599\u306e\u7406\u89e3\u3092\u6df1\u3081\u308b\u305f\u3081\u306b\u3001\u5148\u7aef\u7684\u306a\u6027\u8a55\u4fa1\u6280\u8853\u304c\u4e0d\u53ef\u6b20\u3067\u3059\u3002\u3053\u308c\u3089\u306e\u624b\u2026","rel":"","context":"\u5206\u6790\u30fb\u6e2c\u5b9a\u95a2\u9023","block_context":{"text":"\u5206\u6790\u30fb\u6e2c\u5b9a\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/analysis\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/12\/battery-development-microscopy-csm-25076_eyecatch.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/12\/battery-development-microscopy-csm-25076_eyecatch.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/12\/battery-development-microscopy-csm-25076_eyecatch.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/12\/battery-development-microscopy-csm-25076_eyecatch.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/12\/battery-development-microscopy-csm-25076_eyecatch.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/12\/battery-development-microscopy-csm-25076_eyecatch.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":25200,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/battery-development-battery-manufacturing-csm-26019\/","url_meta":{"origin":798,"position":4},"title":"BTRY\u793e \u306e\u5168\u56fa\u4f53\u96fb\u6c60\u6280\u8853\u3068\u96fb\u6c17\u81ea\u52d5\u8eca\u5411\u3051\u30a8\u30cd\u30eb\u30ae\u30fc\u8caf\u8535\u3078\u306e\u53ef\u80fd\u6027 BTRY AG\u5171\u540c\u5275\u696d\u8005 \u517c CEO Moritz Futscher\u6c0f\u3078\u306e\u30a4\u30f3\u30bf\u30d3\u30e5\u30fc","author":"LatB Staff","date":"2026\u5e745\u670826\u65e5","format":false,"excerpt":"\u539f\u6587\uff08\u82f1\u8a9e\uff09\uff1aBTRY\u2019s solid state battery technology and i\u2026","rel":"","context":"\u5206\u6790\u30fb\u6e2c\u5b9a\u95a2\u9023","block_context":{"text":"\u5206\u6790\u30fb\u6e2c\u5b9a\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/analysis\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/battery-development-battery-manufacturing-csm-26019_eyecatch.jpg?resize=350%2C200&ssl=1","width":350,"height":200},"classes":[]},{"id":24968,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/cloning-protein-expression-bid-ts-mbr-26012_\/","url_meta":{"origin":798,"position":5},"title":"\u5927\u8178\u83cc\u306e\u98fc\u3044\u65b9\uff5e\u5b9f\u9a13\u306b\u5fc5\u8981\u306a\u8a2d\u5099\u3092\u305d\u308d\u3048\u3088\u3046","author":"LatB Staff","date":"2026\u5e743\u670816\u65e5","format":false,"excerpt":"\u5206\u5b50\u751f\u7269\u5b66\u306e\u9ece\u660e\u671f\u3092\u652f\u3048\u3066\u304d\u305f\u5927\u8178\u83cc\uff08Escherichia coli\uff09\u3067\u3059\u304c\u3001\u8fd1\u5e74\u3067\u306f\u5168\u304f\u6271\u308f\u306a\u3044\u2026","rel":"","context":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","block_context":{"text":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/mol-bio\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/03\/cloning-protein-expression-bid-ts-mbr-26012_eyecatch.png?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/03\/cloning-protein-expression-bid-ts-mbr-26012_eyecatch.png?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/03\/cloning-protein-expression-bid-ts-mbr-26012_eyecatch.png?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/03\/cloning-protein-expression-bid-ts-mbr-26012_eyecatch.png?resize=700%2C400&ssl=1 2x"},"classes":[]}],"jetpack_sharing_enabled":true,"amp_enabled":true,"jetpack_featured_media_url":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/how-securely-are-your-data-stored-title.jpg","_links":{"self":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/posts\/798","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/users\/988"}],"replies":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/comments?post=798"}],"version-history":[{"count":0,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/posts\/798\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/media\/3527"}],"wp:attachment":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/media?parent=798"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/categories?post=798"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/tags?post=798"},{"taxonomy":"division","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/division?post=798"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}