{"id":8233,"date":"2021-08-20T14:25:31","date_gmt":"2021-08-20T05:25:31","guid":{"rendered":"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/?p=8233"},"modified":"2021-09-10T16:42:00","modified_gmt":"2021-09-10T07:42:00","slug":"agrigenomics_ma_gsd_ts_3","status":"publish","type":"post","link":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/agrigenomics_ma_gsd_ts_3\/","title":{"rendered":"\u990a\u6b96\u696d\u3067\u306e\u52b9\u679c\u7684\u306a\u30b8\u30a7\u30ce\u30bf\u30a4\u30d4\u30f3\u30b0\uff1aTiago Hori\u535a\u58eb\u3078\u306e\u30a4\u30f3\u30bf\u30d3\u30e5\u30fc"},"content":{"rendered":"<p>\u30e0\u30fc\u30eb\u8c9d\u306e\u5317\u7c73\u6700\u5927\u306e\u751f\u7523\u52a0\u5de5\u696d\u8005\u3067\u3042\u308b\u30a2\u30c8\u30e9\u30f3\u30c6\u30a3\u30c3\u30af\u30a2\u30af\u30a2\u30d5\u30a1\u30fc\u30e0\u793e\u3001\u305d\u306e\u6c34\u7523\u990a\u6b96\u30a4\u30ce\u30d9\u30fc\u30b7\u30e7\u30f3\u30c1\u30fc\u30e0\u306e\u30c7\u30a3\u30ec\u30af\u30bf\u30fc\u3067\u3042\u308bTiago Hori\u535a\u58eb\u306b\u3068\u3063\u3066\u3001\u30b7\u30fc\u30b1\u30f3\u30b7\u30f3\u30b0\u306b\u3088\u308b\u30bf\u30fc\u30b2\u30c3\u30c8\u30b8\u30a7\u30ce\u30bf\u30a4\u30d4\u30f3\u30b0\uff08GBS\uff09\u3092\u6c34\u7523\u990a\u6b96\u306b\u53d6\u308a\u5165\u308c\u308b\u3053\u3068\u306b\u304a\u3051\u308b\u8ab2\u984c\u306f\u3001\u30b3\u30b9\u30c8\u30c0\u30a6\u30f3\u3067\u3057\u305f\u3002Hori\u535a\u58eb\u304c\u898b\u3064\u3051\u305f\u89e3\u6c7a\u7b56\u306fApplied Biosystems\u2122 AgriSeq\u2122\u30d7\u30e9\u30c3\u30c8\u30db\u30fc\u30e0\u3067\u3042\u308a\u3001\u30a2\u30c8\u30e9\u30f3\u30c6\u30a3\u30c3\u30af\u30a2\u30af\u30a2\u30d5\u30a1\u30fc\u30e0\u793e\u3067\u306e\u52b9\u679c\u7684\u306a\u6d3b\u7528\u65b9\u6cd5\u306b\u3064\u3044\u3066\u3054\u7d39\u4ecb\u3044\u305f\u3060\u304d\u307e\u3057\u305f\u3002<\/p>\n<p><iframe loading=\"lazy\" title=\"Using the Medium Density Panels to Increase the Feasibility of Imputation-Based Genomic Selection\" width=\"760\" height=\"428\" src=\"https:\/\/www.youtube.com\/embed\/XUGl9raLMmk?feature=oembed\" frameborder=\"0\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture\" allowfullscreen><\/iframe><\/p>\n<h2>AgriSeq Target GBS\u30bd\u30ea\u30e5\u30fc\u30b7\u30e7\u30f3\u3092\u3069\u306e\u3088\u3046\u306b\u6d3b\u7528\u3057\u3066\u3044\u307e\u3059\u304b\uff1f<\/h2>\n<p>\u6c34\u7523\u990a\u6b96\u305d\u308c\u81ea\u4f53\u304c\u3001Hori\u535a\u58eb\u3068\u30a2\u30c8\u30e9\u30f3\u30c6\u30a3\u30c3\u30af\u30a2\u30af\u30a2\u30d5\u30a1\u30fc\u30e0\u304c\u76f4\u9762\u3057\u305f\u8ab2\u984c\u3067\u3057\u305f\u3002\u300c\u591a\u304f\u306e\u5bb6\u755c\u306e\u5834\u5408\u3001\u4e00\u982d\u3042\u305f\u308a\u306e\u4fa1\u5024\u304c\u975e\u5e38\u306b\u9ad8\u3044\u305f\u3081\u3001\u7e41\u6b96\u306e\u305f\u3081\u306e\u30b2\u30ce\u30e0\u9078\u629e\u306f\u3001Applied Biosystems\u2122 <a href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/life-science\/microarray-analysis\/agrigenomics-solutions-microarrays-gbs.html?CID=Social_LAB\" target=\"_blank\" rel=\"noopener noreferrer\">Axiom<\/a> \u306e\u3088\u3046\u306a\u9ad8\u5bc6\u5ea6\u30a2\u30ec\u30a4\u3092\u4f7f\u7528\u3057\u3066\u884c\u308f\u308c\u307e\u3059\u300d\u3068Hori\u535a\u58eb\u306f\u8aac\u660e\u3057\u307e\u3059\u3002\u300c\u6c34\u7523\u990a\u6b96\u3067\u306f\u30011\u5339\u3042\u305f\u308a\u306e\u4fa1\u5024\u304c\u975e\u5e38\u306b\u4f4e\u3044\u305f\u3081\u3001\u500b\u4f53\u3042\u305f\u308a\u306e\u907a\u4f1d\u5b50\u578b\u6c7a\u5b9a\u30b3\u30b9\u30c8\u3092\u524a\u6e1b\u3059\u308b\u3088\u3046\u52aa\u3081\u306a\u3051\u308c\u3070\u306a\u308a\u307e\u305b\u3093\u3002\u300d\u3053\u308c\u306f\u3001\u5927\u898f\u6a21\u30d1\u30cd\u30eb\u3092\u4f7f\u7528\u3059\u308b\u306e\u3067\u306f\u306a\u304f\u3001\u4fa1\u5024\u306e\u9ad8\u3044\u30b2\u30ce\u30e0\u30bf\u30fc\u30b2\u30c3\u30c8\u3092\u898b\u3064\u3051\u3066\u3001\u305d\u308c\u3089\u306b\u30d5\u30a9\u30fc\u30ab\u30b9\u3059\u308b\u3053\u3068\u3092\u610f\u5473\u3057\u307e\u3059\u3002<\/p>\n<p>\u30a2\u30c8\u30e9\u30f3\u30c6\u30a3\u30c3\u30af\u30a2\u30af\u30a2\u30d5\u30a1\u30fc\u30e0\u793e\u306f\u3001\u9ad8\u5bc6\u5ea6\u306eApplied Biosystems\u2122 <a href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/life-science\/microarray-analysis\/agrigenomics-solutions-microarrays-gbs\/axiom-genotyping-solution-agrigenomics.html?CID=gsd_agr_agn_r04_jp_cp1427_pjt6899_gsd00000_0so_blg_op_awa_og_s00_ma16_Social_LAB\" target=\"_blank\" rel=\"noopener noreferrer\">Axiom\u30a2\u30ec\u30a4<\/a>\u304c\u5229\u7528\u53ef\u80fd\u306b\u306a\u308a\u6b21\u7b2c\u3001\u4f7f\u7528\u3092\u958b\u59cb\u3057\u307e\u3057\u305f\u3002\u3053\u308c\u306b\u3088\u308a\u3001\u96c6\u56e3\u5185\u3067\u6709\u610f\u306b\u5909\u52d5\u3059\u308b\u7d0450,000\u306e\u4e00\u5869\u57fa\u591a\u578b\uff08SNP\uff09\u30b5\u30a4\u30c8\u3092\u30b2\u30ce\u30e0\u5168\u4f53\u306b\u308f\u305f\u3063\u3066\u7279\u5b9a\u3067\u304d\u3001\u305d\u306e\u60c5\u5831\u3092\u4f7f\u7528\u3057\u3066\u3001\u3088\u308a\u5c11\u306a\u3044SNP\u3092\u5bfe\u8c61\u3068\u3059\u308b\u5b89\u4fa1\u306a384\u30a2\u30ec\u30a4\u3092\u69cb\u7bc9\u3057\u307e\u3057\u305f\u3002Hori\u535a\u58eb\u306f\u3055\u3089\u306b\u3001\u751f\u7269\u7a2e\u3054\u3068\u306b\u7279\u5316\u3057\u305f2,000\uff5e3,000\u306e\u3082\u3063\u3068\u3082\u6709\u7528\u306aSNP\u3092\u5099\u3048\u305fApplied Biosystems\u2122 <a href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/life-science\/agricultural-biotechnology\/agrigenomics\/agriseq-targeted-genotyping-sequencing.html?CID=gsd_agr_agn_r04_jp_cp1427_pjt6899_gsd00000_0so_blg_op_awa_og_s00_ma16_Social_LAB\" target=\"_blank\" rel=\"noopener noreferrer\">AgriSeq\u30d1\u30cd\u30eb<\/a>\u3092\u958b\u767a\u3059\u308b\u3053\u3068\u306b\u3088\u308a\u3001\u5927\u304d\u306a\u30b3\u30b9\u30c8\u524a\u6e1b\u3092\u9054\u6210\u3057\u307e\u3057\u305f\u3002<\/p>\n<h2>\u5c02\u7528\u306b\u958b\u767a\u3055\u308c\u305fAgriSeq\u30d1\u30cd\u30eb\u3092\u4f7f\u7528\u3059\u308b\u7406\u7531<\/h2>\n<p>Hori\u535a\u58eb\u306f\u300c\u3053\u306e\u30d7\u30e9\u30c3\u30c8\u30db\u30fc\u30e0\u306f\u3001\u6c34\u7523\u990a\u6b96\u306b\u304a\u3051\u308b\u30b2\u30ce\u30e0\u9078\u629e\u3092\u52b9\u679c\u7684\u306b\u5b9f\u73fe\u3059\u308b\u552f\u4e00\u306e\u65b9\u6cd5\u3067\u3059\u300d\u3068\u30b7\u30f3\u30d7\u30eb\u306b\u8aac\u660e\u3057\u3066\u3044\u307e\u3059\u3002AgriSeq\u30d1\u30cd\u30eb\u306f\u3001\u4f4e\u5bc6\u5ea6\u306aPCR\u6cd5\u3068\u9ad8\u5bc6\u5ea6\u3067\u3042\u308b\u304c\u3088\u308a\u9ad8\u4fa1\u306a\u30a2\u30ec\u30a4\u306e\u4e2d\u9593\u3068\u306a\u308b\u30011,000\uff5e5,000\u30ab\u6240\u306eSNP\u30bf\u30a4\u30d4\u30f3\u30b0\u3092\u4f4e\u30b3\u30b9\u30c8\u3067\u5b9f\u73fe\u3057\u307e\u3059\u3002Hori\u535a\u58eb\u3068\u5f7c\u306e\u30c1\u30fc\u30e0\u306f\u3001\u4ee5\u524d\u304b\u3089\u990a\u6b96\u3055\u308c\u3066\u78ba\u7acb\u3055\u308c\u3066\u3044\u308b\u7a2e\u3067\u306f\u306a\u3044\u3001\u3064\u307e\u308a\u300c\u65e2\u306b\u30a2\u30ec\u30a4\u304c\u5b58\u5728\u3059\u308b\u30a2\u30c8\u30e9\u30f3\u30c6\u30a3\u30c3\u30af\u30b5\u30fc\u30e2\u30f3\u3067\u5229\u7528\u3067\u304d\u308b\u3088\u3046\u306a\u30ea\u30bd\u30fc\u30b9\u3092\u6301\u3063\u3066\u3044\u306a\u3044\u300d\u65b0\u305f\u306a\u990a\u6b96\u7a2e\u306b\u30b2\u30ce\u30e0\u9078\u629e\u3092\u9069\u7528\u3067\u304d\u307e\u3059\u3002<\/p>\n<h2>AgriSeq\u30c6\u30af\u30ce\u30ed\u30b8\u30fc\u3092\u63a1\u7528\u3057\u3066\u3088\u304b\u3063\u305f\u70b9\u306f\uff1f<\/h2>\n<p>Hori\u535a\u58eb\u306f\u3001Axiom\u30c6\u30af\u30ce\u30ed\u30b8\u30fc\u304c\u5f7c\u306e\u696d\u52d9\u3067\u6a5f\u80fd\u3059\u308b\u304b\u3069\u3046\u304b\u306b\u3064\u3044\u3066\u306f\u5fc3\u914d\u3057\u3066\u3044\u307e\u305b\u3093\u3067\u3057\u305f\u3002\u3080\u3057\u308d\u3001\u5f7c\u306e\u61f8\u5ff5\u306fAgriSeq\u30d7\u30e9\u30c3\u30c8\u30d5\u30a9\u30fc\u30e0\u3067\u3057\u305f\u3002\u300c\u30a2\u30ec\u30a4\u3092\u4f7f\u7528\u3059\u308b\u3053\u3068\u306f\u4ed6\u306e\u30b0\u30eb\u30fc\u30d7\u306b\u3088\u3063\u3066\u904e\u53bb\u306b\u691c\u8a3c\u3055\u308c\u3066\u3044\u305f\u305f\u3081\u5fc3\u914d\u3057\u3066\u3044\u307e\u305b\u3093\u3067\u3057\u305f\u304c\u3001\u4e00\u90e8\u306e\u6c34\u751f\u52d5\u7269\u306f\u975e\u5e38\u306b\u8907\u96d1\u306a\u30b2\u30ce\u30e0\u3092\u6301\u3063\u3066\u3044\u308b\u305f\u3081\u3001AgriSeq\u30d7\u30e9\u30c3\u30c8\u30db\u30fc\u30e0\u304c\u6b63\u3057\u304f\u6a5f\u80fd\u3059\u308b\u304b\u5c11\u3057\u5fc3\u914d\u3057\u307e\u3057\u305f\u300d\u3002\u4e00\u90e8\u306e\u9b5a\u306f\u3001\u6700\u5927400\u672c\u306e\u67d3\u8272\u4f53\u3068\u3001\u6700\u59274\u500d\u4f53\u306e\u500d\u6570\u6027\u3092\u6301\u3064\u53ef\u80fd\u6027\u304c\u3042\u308a\u3001\u5f93\u6765\u306e\u52d5\u7269\u30b2\u30ce\u30df\u30af\u30b9\u624b\u6cd5\u306b\u6bd4\u3079\u8907\u96d1\u3067\u3059\u3002<\/p>\n<p>\u5909\u7570\u691c\u51fa\u3068\u30de\u30c3\u30d4\u30f3\u30b0\u306e\u30a8\u30e9\u30fc\u306b\u3064\u3044\u3066\u61f8\u5ff5\u304c\u3042\u308a\u307e\u3057\u305f\u304c\u3001Hori\u535a\u58eb\u306e\u30c1\u30fc\u30e0\u306f\u3001\u5f53\u793e\u3068\u5354\u529b\u3057\u3066\u3001\u8907\u96d1\u306a\u30b2\u30ce\u30e0\u306b\u5bfe\u3059\u308b\u3044\u304f\u3064\u304b\u306e\u30d1\u30cd\u30eb\u3092\u958b\u767a\u3067\u304d\u3001\u305d\u308c\u3089\u30ab\u30b9\u30bf\u30e0\u30c7\u30b6\u30a4\u30f3\u306e\u30d1\u30cd\u30eb\u306f\u3046\u307e\u304f\u6a5f\u80fd\u3057\u307e\u3057\u305f\u3002\u30b5\u30fc\u30e2\u30d5\u30a3\u30c3\u30b7\u30e3\u30fc\u30b5\u30a4\u30a8\u30f3\u30c6\u30a3\u30d5\u30a3\u30c3\u30af\u306e\u30aa\u30fc\u30b9\u30c6\u30a3\u30f3\u30c1\u30fc\u30e0\uff08AgriSeq\u306e\u958b\u767a\u30c1\u30fc\u30e0\u306f\u30c6\u30ad\u30b5\u30b9\u5dde\u30aa\u30fc\u30b9\u30c6\u30a3\u30f3\u306b\u3042\u308a\u307e\u3059\uff09\u306b\u3064\u3044\u3066\u300c\u30d0\u30a4\u30aa\u30a4\u30f3\u30d5\u30a9\u30de\u30c6\u30a3\u30af\u30b9\u6280\u8853\u3092\u901a\u3058\u3066\u79c1\u305f\u3061\u3092\u52a9\u3051\u3066\u304f\u308c\u307e\u3057\u305f\u3002\u79c1\u305f\u3061\u306e\u30b2\u30ce\u30e0\u306f\u5927\u304d\u3059\u304e\u3066\u3001\u8a2d\u8a08\u306b\u306f\u901a\u5e38\u306eWeb\u30d7\u30e9\u30c3\u30c8\u30db\u30fc\u30e0\u3092\u4f7f\u7528\u3067\u304d\u306a\u304b\u3063\u305f\u305f\u3081\u3001\u30b5\u30fc\u30e2\u30d5\u30a3\u30c3\u30b7\u30e3\u30fc\u5074\u3067\u30c7\u30b6\u30a4\u30f3\u3092\u884c\u3063\u3066\u304f\u308c\u307e\u3057\u305f\u300d\u3068Hori\u535a\u58eb\u306f\u8aac\u660e\u3057\u307e\u3059\u3002\u300c\u3068\u3066\u3082\u3044\u3044\u7d4c\u9a13\u3067\u3057\u305f\u3002\u300d<\/p>\n<h2>\u4eca\u5f8c\u3069\u306e\u3088\u3046\u306b\u696d\u52d9\u304c\u9032\u5c55\u3057\u3066\u3044\u304f\u3068\u601d\u3044\u307e\u3059\u304b\uff1f<\/h2>\n<p>\u9b5a\u985e\u7528\u306eAgriSeq\u30d1\u30cd\u30eb\u306e\u4f5c\u6210\u306b\u6210\u529f\u3057\u305f\u5f8c\u3001\u30a2\u30c8\u30e9\u30f3\u30c6\u30a3\u30c3\u30af\u30a2\u30af\u30a2\u30d5\u30a1\u30fc\u30e0\u793e\u306f\u3001\u3053\u306e\u30d7\u30ed\u30bb\u30b9\u3092\u8c9d\u985e\u3001\u3064\u307e\u308a\u9b5a\u985e\u3068\u306f\u975e\u5e38\u306b\u7570\u306a\u308b\u30b2\u30ce\u30e0\u3092\u6301\u3061\u3001\u4e00\u5339\u3042\u305f\u308a\u306e\u4fa1\u5024\u304c\u3055\u3089\u306b\u4f4e\u3044\u65b0\u8208\u7a2e\u306b\u5fdc\u7528\u3059\u308b\u3053\u3068\u306b\u95a2\u5fc3\u3092\u6301\u3063\u3066\u3044\u307e\u3059\u3002\u3053\u308c\u3092\u5ff5\u982d\u306b\u7f6e\u3044\u3066\u5f7c\u3089\u306f\u3001\u3088\u308a\u591a\u304f\u306e\u751f\u7269\u7a2e\u306b\u3064\u3044\u3066\u3001\u7d4c\u6e08\u7684\u3067\u3042\u308a\u306a\u304c\u3089\u30b2\u30ce\u30e0\u9078\u629e\u306e\u305f\u3081\u306e\u5341\u5206\u5305\u62ec\u7684\u306a\u60c5\u5831\u3092\u5f97\u308b\u3053\u3068\u304c\u3067\u304d\u308b\u30dd\u30a4\u30f3\u30c8\u3092\u898b\u3064\u3051\u308b\u305f\u3081\u306b\u30011,000\u3055\u3089\u306b\u306f500 SNP\u3068\u3044\u3063\u305f\u3088\u308a\u7126\u70b9\u3092\u7d5e\u3063\u305f\u30d1\u30cd\u30eb\u3092\u6c42\u3081\u3066\u3044\u307e\u3059\u3002Hori\u535a\u58eb\u306f\u300c\u6c34\u7523\u990a\u6b96\u306e\u30b8\u30a7\u30ce\u30bf\u30a4\u30d4\u30f3\u30b0\u306b\u304a\u3044\u3066\u3001\u53ef\u80fd\u306a\u9650\u308a\u306e\u4f4e\u30b3\u30b9\u30c8\u5316\u3092\u5e38\u306b\u8ffd\u6c42\u3059\u308b\u3064\u3082\u308a\u3067\u3059\u300d\u3068\u8a9e\u3063\u3066\u3044\u307e\u3059\u3002\u5f53\u793e\u306f\u5f7c\u3089\u304c\u305d\u308c\u3092\u5b9f\u73fe\u3059\u308b\u306e\u3092\u652f\u63f4\u3059\u308b\u6e96\u5099\u304c\u3067\u304d\u3066\u3044\u307e\u3059\u3002<\/p>\n<p>\u30a2\u30b0\u30ea\u30b2\u30ce\u30df\u30af\u30b9\u3092\u6c34\u7523\u990a\u6b96\u306b\u5c0e\u5165\u3059\u308b\u65b9\u6cd5\u306e\u8a73\u7d30\u306b\u3064\u3044\u3066\u306f\u3001\u5f53\u793e\u306e<a href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/life-science\/agricultural-biotechnology\/agrigenomics\/agrigenomics-solutions-aquaculture.html?CID=gsd_agr_agn_r04_jp_cp1427_pjt6899_gsd00000_0so_blg_op_awa_og_s00_ma16_Social_LAB\" target=\"_blank\" rel=\"noopener noreferrer\">\u30a2\u30b0\u30ea\u30b2\u30ce\u30df\u30af\u30b9<\/a>\u95a2\u9023\u88fd\u54c1\u30da\u30fc\u30b8\u3092\u3001\u30de\u30a4\u30af\u30ed\u30a2\u30ec\u30a4\u3068GBS\u3092\u7528\u3044\u305f\u30a2\u30b0\u30ea\u30b2\u30ce\u30df\u30af\u30b9\u30bd\u30ea\u30e5\u30fc\u30b7\u30e7\u30f3\u306b\u3064\u3044\u3066\u306f\u3001<a href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/life-science\/microarray-analysis\/agrigenomics-solutions-microarrays-gbs.html?CID=gsd_agr_agn_r04_jp_cp1427_pjt6899_gsd00000_0so_blg_op_awa_og_s00_ma16_Social_LAB\" target=\"_blank\" rel=\"noopener\">\u3053\u3061\u3089<\/a>\u3092\u3054\u89a7\u304f\u3060\u3055\u3044\u3002<a href=\"https:\/\/assets.thermofisher.com\/TFS-Assets\/GSD\/brochures\/agrigenomics-brochure.pdf?cid=gsd_agr_agn_r04_jp_cp1427_pjt6899_gsd00000_0so_blg_op_awa_og_s00_ma16_Social_LAB\" target=\"_blank\" rel=\"noopener noreferrer\">\u30d1\u30f3\u30d5\u30ec\u30c3\u30c8\u306e\u30c0\u30a6\u30f3\u30ed\u30fc\u30c9<\/a>\u304a\u3088\u3073\u3001<a href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/global\/forms\/industrial\/agrigenomics-contact-request.html?CID=gsd_agr_agn_r04_jp_cp1427_pjt6899_gsd00000_0so_blg_op_awa_og_s00_ma16_Social_LAB\" target=\"_blank\" rel=\"noopener noreferrer\">\u304a\u554f\u3044\u5408\u308f\u305b\u30d5\u30a9\u30fc\u30e0<\/a>\u304b\u3089\u76f4\u63a5\u3054\u8cea\u554f\u3044\u305f\u3060\u304f\u3053\u3068\u3082\u53ef\u80fd\u3067\u3059\u3002<\/p>\n<p>&nbsp;<\/p>\n<p>\u7814\u7a76\u7528\u306b\u306e\u307f\u4f7f\u7528\u3067\u304d\u307e\u3059\u3002\u8a3a\u65ad\u76ee\u7684\u304a\u3088\u3073\u305d\u306e\u624b\u7d9a\u304d\u4e0a\u3067\u306e\u4f7f\u7528\u306f\u3067\u304d\u307e\u305b\u3093\u3002<\/p>\n","protected":false},"excerpt":{"rendered":"<p>\u30e0\u30fc\u30eb\u8c9d\u306e\u5317\u7c73\u6700\u5927\u306e\u751f\u7523\u52a0\u5de5\u696d\u8005\u3067\u3042\u308b\u30a2\u30c8\u30e9\u30f3\u30c6\u30a3\u30c3\u30af\u30a2\u30af\u30a2\u30d5\u30a1\u30fc\u30e0\u793e\u3001\u305d\u306e\u6c34\u7523\u990a\u6b96\u30a4\u30ce\u30d9\u30fc\u30b7\u30e7\u30f3\u30c1\u30fc\u30e0\u306e\u30c7\u30a3\u30ec\u30af\u30bf\u30fc\u3067\u3042\u308bTiago Hori\u535a\u58eb\u306b\u3068\u3063\u3066\u3001\u30b7\u30fc\u30b1\u30f3\u30b7\u30f3\u30b0\u306b\u3088\u308b\u30bf\u30fc\u30b2\u30c3\u30c8\u30b8\u30a7\u30ce\u30bf\u30a4\u30d4\u30f3\u30b0\uff08GBS\uff09\u3092\u6c34\u7523<\/p>\n","protected":false},"author":975,"featured_media":9839,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_monsterinsights_skip_tracking":false,"_genesis_hide_title":false,"_genesis_hide_breadcrumbs":false,"_genesis_hide_singular_image":false,"_genesis_hide_footer_widgets":false,"_genesis_custom_body_class":"","_genesis_custom_post_class":"","_genesis_layout":"","_jetpack_newsletter_access":"","_jetpack_dont_email_post_to_subs":false,"_jetpack_newsletter_tier_id":0,"_jetpack_memberships_contains_paywalled_content":false,"_jetpack_hide_featured_image":false,"_jetpack_featured_image_duplicate_dismissed":0,"_jetpack_feature_clip_id":0,"_jetpack_memberships_contains_paid_content":false,"footnotes":"","jetpack_post_was_ever_published":false},"categories":[156],"tags":[71],"division":[],"class_list":["post-8233","post","type-post","status-publish","format-standard","has-post-thumbnail","category-mol-bio","tag-microarray","entry"],"_selected_authors":"","_selected_reviewers":"","acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v28.9 (Yoast SEO v28.9) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>\u990a\u6b96\u696d\u3067\u306e\u52b9\u679c\u7684\u306a\u30b8\u30a7\u30ce\u30bf\u30a4\u30d4\u30f3\u30b0\uff1aTiago Hori\u535a\u58eb\u3078\u306e\u30a4\u30f3\u30bf\u30d3\u30e5\u30fc - Learning at the Bench<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/agrigenomics_ma_gsd_ts_3\/\" \/>\n<meta property=\"og:locale\" content=\"ja_JP\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"\u990a\u6b96\u696d\u3067\u306e\u52b9\u679c\u7684\u306a\u30b8\u30a7\u30ce\u30bf\u30a4\u30d4\u30f3\u30b0\uff1aTiago Hori\u535a\u58eb\u3078\u306e\u30a4\u30f3\u30bf\u30d3\u30e5\u30fc\" \/>\n<meta property=\"og:description\" content=\"\u30e0\u30fc\u30eb\u8c9d\u306e\u5317\u7c73\u6700\u5927\u306e\u751f\u7523\u52a0\u5de5\u696d\u8005\u3067\u3042\u308b\u30a2\u30c8\u30e9\u30f3\u30c6\u30a3\u30c3\u30af\u30a2\u30af\u30a2\u30d5\u30a1\u30fc\u30e0\u793e\u3001\u305d\u306e\u6c34\u7523\u990a\u6b96\u30a4\u30ce\u30d9\u30fc\u30b7\u30e7\u30f3\u30c1\u30fc\u30e0\u306e\u30c7\u30a3\u30ec\u30af\u30bf\u30fc\u3067\u3042\u308bTiago Hori\u535a\u58eb\u306b\u3068\u3063\u3066\u3001\u30b7\u30fc\u30b1\u30f3\u30b7\u30f3\u30b0\u306b\u3088\u308b\u30bf\u30fc\u30b2\u30c3\u30c8\u30b8\u30a7\u30ce\u30bf\u30a4\u30d4\u30f3\u30b0\uff08GBS\uff09\u3092\u6c34\u7523\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/agrigenomics_ma_gsd_ts_3\/\" \/>\n<meta property=\"og:site_name\" content=\"Learning at the Bench\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/ThermoFisherJapan\" \/>\n<meta property=\"article:published_time\" content=\"2021-08-20T05:25:31+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2021-09-10T07:42:00+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2021\/08\/shutterstock_1938816793-scaled.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"2560\" \/>\n\t<meta property=\"og:image:height\" content=\"1707\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"LatB Staff\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:creator\" content=\"@ThermoFisherJP\" \/>\n<meta name=\"twitter:site\" content=\"@ThermoFisherJP\" \/>\n<meta name=\"twitter:label1\" content=\"\u57f7\u7b46\u8005\" \/>\n\t<meta name=\"twitter:data1\" content=\"LatB Staff\" \/>\n\t<meta name=\"twitter:label2\" content=\"\u63a8\u5b9a\u8aad\u307f\u53d6\u308a\u6642\u9593\" \/>\n\t<meta name=\"twitter:data2\" content=\"1\u5206\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/agrigenomics_ma_gsd_ts_3\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/agrigenomics_ma_gsd_ts_3\\\/\"},\"author\":{\"name\":\"LatB Staff\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#\\\/schema\\\/person\\\/8fb77bfc3606f049738f28976032baa7\"},\"headline\":\"\u990a\u6b96\u696d\u3067\u306e\u52b9\u679c\u7684\u306a\u30b8\u30a7\u30ce\u30bf\u30a4\u30d4\u30f3\u30b0\uff1aTiago Hori\u535a\u58eb\u3078\u306e\u30a4\u30f3\u30bf\u30d3\u30e5\u30fc\",\"datePublished\":\"2021-08-20T05:25:31+00:00\",\"dateModified\":\"2021-09-10T07:42:00+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/agrigenomics_ma_gsd_ts_3\\\/\"},\"wordCount\":52,\"commentCount\":0,\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/agrigenomics_ma_gsd_ts_3\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2021\\\/08\\\/shutterstock_1938816793-scaled.jpg\",\"keywords\":[\"\u30de\u30a4\u30af\u30ed\u30a2\u30ec\u30a4\"],\"articleSection\":[\"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023\"],\"inLanguage\":\"ja\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/agrigenomics_ma_gsd_ts_3\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/agrigenomics_ma_gsd_ts_3\\\/\",\"url\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/agrigenomics_ma_gsd_ts_3\\\/\",\"name\":\"\u990a\u6b96\u696d\u3067\u306e\u52b9\u679c\u7684\u306a\u30b8\u30a7\u30ce\u30bf\u30a4\u30d4\u30f3\u30b0\uff1aTiago Hori\u535a\u58eb\u3078\u306e\u30a4\u30f3\u30bf\u30d3\u30e5\u30fc - Learning at the Bench\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/agrigenomics_ma_gsd_ts_3\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/agrigenomics_ma_gsd_ts_3\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2021\\\/08\\\/shutterstock_1938816793-scaled.jpg\",\"datePublished\":\"2021-08-20T05:25:31+00:00\",\"dateModified\":\"2021-09-10T07:42:00+00:00\",\"author\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#\\\/schema\\\/person\\\/8fb77bfc3606f049738f28976032baa7\"},\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/agrigenomics_ma_gsd_ts_3\\\/#breadcrumb\"},\"inLanguage\":\"ja\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/agrigenomics_ma_gsd_ts_3\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"ja\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/agrigenomics_ma_gsd_ts_3\\\/#primaryimage\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2021\\\/08\\\/shutterstock_1938816793-scaled.jpg\",\"contentUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2021\\\/08\\\/shutterstock_1938816793-scaled.jpg\",\"width\":2560,\"height\":1707},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/agrigenomics_ma_gsd_ts_3\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"\u990a\u6b96\u696d\u3067\u306e\u52b9\u679c\u7684\u306a\u30b8\u30a7\u30ce\u30bf\u30a4\u30d4\u30f3\u30b0\uff1aTiago Hori\u535a\u58eb\u3078\u306e\u30a4\u30f3\u30bf\u30d3\u30e5\u30fc\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#website\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/\",\"name\":\"Learning at the Bench\",\"description\":\"\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"ja\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#\\\/schema\\\/person\\\/8fb77bfc3606f049738f28976032baa7\",\"name\":\"LatB Staff\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"ja\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g\",\"caption\":\"LatB Staff\"},\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/author\\\/lgbadmin\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"\u990a\u6b96\u696d\u3067\u306e\u52b9\u679c\u7684\u306a\u30b8\u30a7\u30ce\u30bf\u30a4\u30d4\u30f3\u30b0\uff1aTiago Hori\u535a\u58eb\u3078\u306e\u30a4\u30f3\u30bf\u30d3\u30e5\u30fc - Learning at the Bench","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/agrigenomics_ma_gsd_ts_3\/","og_locale":"ja_JP","og_type":"article","og_title":"\u990a\u6b96\u696d\u3067\u306e\u52b9\u679c\u7684\u306a\u30b8\u30a7\u30ce\u30bf\u30a4\u30d4\u30f3\u30b0\uff1aTiago Hori\u535a\u58eb\u3078\u306e\u30a4\u30f3\u30bf\u30d3\u30e5\u30fc","og_description":"\u30e0\u30fc\u30eb\u8c9d\u306e\u5317\u7c73\u6700\u5927\u306e\u751f\u7523\u52a0\u5de5\u696d\u8005\u3067\u3042\u308b\u30a2\u30c8\u30e9\u30f3\u30c6\u30a3\u30c3\u30af\u30a2\u30af\u30a2\u30d5\u30a1\u30fc\u30e0\u793e\u3001\u305d\u306e\u6c34\u7523\u990a\u6b96\u30a4\u30ce\u30d9\u30fc\u30b7\u30e7\u30f3\u30c1\u30fc\u30e0\u306e\u30c7\u30a3\u30ec\u30af\u30bf\u30fc\u3067\u3042\u308bTiago Hori\u535a\u58eb\u306b\u3068\u3063\u3066\u3001\u30b7\u30fc\u30b1\u30f3\u30b7\u30f3\u30b0\u306b\u3088\u308b\u30bf\u30fc\u30b2\u30c3\u30c8\u30b8\u30a7\u30ce\u30bf\u30a4\u30d4\u30f3\u30b0\uff08GBS\uff09\u3092\u6c34\u7523","og_url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/agrigenomics_ma_gsd_ts_3\/","og_site_name":"Learning at the Bench","article_publisher":"https:\/\/www.facebook.com\/ThermoFisherJapan","article_published_time":"2021-08-20T05:25:31+00:00","article_modified_time":"2021-09-10T07:42:00+00:00","og_image":[{"width":2560,"height":1707,"url":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2021\/08\/shutterstock_1938816793-scaled.jpg","type":"image\/jpeg"}],"author":"LatB Staff","twitter_card":"summary_large_image","twitter_creator":"@ThermoFisherJP","twitter_site":"@ThermoFisherJP","twitter_misc":{"\u57f7\u7b46\u8005":"LatB Staff","\u63a8\u5b9a\u8aad\u307f\u53d6\u308a\u6642\u9593":"1\u5206"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/agrigenomics_ma_gsd_ts_3\/#article","isPartOf":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/agrigenomics_ma_gsd_ts_3\/"},"author":{"name":"LatB Staff","@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#\/schema\/person\/8fb77bfc3606f049738f28976032baa7"},"headline":"\u990a\u6b96\u696d\u3067\u306e\u52b9\u679c\u7684\u306a\u30b8\u30a7\u30ce\u30bf\u30a4\u30d4\u30f3\u30b0\uff1aTiago Hori\u535a\u58eb\u3078\u306e\u30a4\u30f3\u30bf\u30d3\u30e5\u30fc","datePublished":"2021-08-20T05:25:31+00:00","dateModified":"2021-09-10T07:42:00+00:00","mainEntityOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/agrigenomics_ma_gsd_ts_3\/"},"wordCount":52,"commentCount":0,"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/agrigenomics_ma_gsd_ts_3\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2021\/08\/shutterstock_1938816793-scaled.jpg","keywords":["\u30de\u30a4\u30af\u30ed\u30a2\u30ec\u30a4"],"articleSection":["\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023"],"inLanguage":"ja","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/agrigenomics_ma_gsd_ts_3\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/agrigenomics_ma_gsd_ts_3\/","url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/agrigenomics_ma_gsd_ts_3\/","name":"\u990a\u6b96\u696d\u3067\u306e\u52b9\u679c\u7684\u306a\u30b8\u30a7\u30ce\u30bf\u30a4\u30d4\u30f3\u30b0\uff1aTiago Hori\u535a\u58eb\u3078\u306e\u30a4\u30f3\u30bf\u30d3\u30e5\u30fc - Learning at the Bench","isPartOf":{"@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/agrigenomics_ma_gsd_ts_3\/#primaryimage"},"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/agrigenomics_ma_gsd_ts_3\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2021\/08\/shutterstock_1938816793-scaled.jpg","datePublished":"2021-08-20T05:25:31+00:00","dateModified":"2021-09-10T07:42:00+00:00","author":{"@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#\/schema\/person\/8fb77bfc3606f049738f28976032baa7"},"breadcrumb":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/agrigenomics_ma_gsd_ts_3\/#breadcrumb"},"inLanguage":"ja","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/agrigenomics_ma_gsd_ts_3\/"]}]},{"@type":"ImageObject","inLanguage":"ja","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/agrigenomics_ma_gsd_ts_3\/#primaryimage","url":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2021\/08\/shutterstock_1938816793-scaled.jpg","contentUrl":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2021\/08\/shutterstock_1938816793-scaled.jpg","width":2560,"height":1707},{"@type":"BreadcrumbList","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/agrigenomics_ma_gsd_ts_3\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/"},{"@type":"ListItem","position":2,"name":"\u990a\u6b96\u696d\u3067\u306e\u52b9\u679c\u7684\u306a\u30b8\u30a7\u30ce\u30bf\u30a4\u30d4\u30f3\u30b0\uff1aTiago Hori\u535a\u58eb\u3078\u306e\u30a4\u30f3\u30bf\u30d3\u30e5\u30fc"}]},{"@type":"WebSite","@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#website","url":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/","name":"Learning at the Bench","description":"","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"ja"},{"@type":"Person","@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#\/schema\/person\/8fb77bfc3606f049738f28976032baa7","name":"LatB Staff","image":{"@type":"ImageObject","inLanguage":"ja","@id":"https:\/\/secure.gravatar.com\/avatar\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g","caption":"LatB Staff"},"url":"https:\/\/admin.acceleratingscience.com\/author\/lgbadmin\/"}]}},"taxonomy_info":{"category":[{"value":156,"label":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023"}],"post_tag":[{"value":71,"label":"\u30de\u30a4\u30af\u30ed\u30a2\u30ec\u30a4"}]},"featured_image_src_large":["https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2021\/08\/shutterstock_1938816793-1024x683.jpg",760,507,true],"author_info":{"display_name":"LatB Staff","author_link":"https:\/\/admin.acceleratingscience.com\/author\/lgbadmin\/"},"comment_info":0,"category_info":[{"term_id":156,"name":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","slug":"mol-bio","term_group":0,"term_taxonomy_id":156,"taxonomy":"category","description":"","parent":0,"count":540,"filter":"raw","meta":[],"cat_ID":156,"category_count":540,"category_description":"","cat_name":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","category_nicename":"mol-bio","category_parent":0}],"tag_info":[{"term_id":71,"name":"\u30de\u30a4\u30af\u30ed\u30a2\u30ec\u30a4","slug":"microarray","term_group":0,"term_taxonomy_id":71,"taxonomy":"post_tag","description":"","parent":0,"count":28,"filter":"raw","meta":[]}],"jetpack-related-posts":[{"id":25200,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/battery-development-battery-manufacturing-csm-26019\/","url_meta":{"origin":8233,"position":0},"title":"BTRY\u793e \u306e\u5168\u56fa\u4f53\u96fb\u6c60\u6280\u8853\u3068\u96fb\u6c17\u81ea\u52d5\u8eca\u5411\u3051\u30a8\u30cd\u30eb\u30ae\u30fc\u8caf\u8535\u3078\u306e\u53ef\u80fd\u6027 BTRY AG\u5171\u540c\u5275\u696d\u8005 \u517c CEO Moritz Futscher\u6c0f\u3078\u306e\u30a4\u30f3\u30bf\u30d3\u30e5\u30fc","author":"LatB Staff","date":"2026\u5e745\u670826\u65e5","format":false,"excerpt":"\u539f\u6587\uff08\u82f1\u8a9e\uff09\uff1aBTRY\u2019s solid state battery technology and i\u2026","rel":"","context":"\u5206\u6790\u30fb\u6e2c\u5b9a\u95a2\u9023","block_context":{"text":"\u5206\u6790\u30fb\u6e2c\u5b9a\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/analysis\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/battery-development-battery-manufacturing-csm-26019_eyecatch.jpg?resize=350%2C200&ssl=1","width":350,"height":200},"classes":[]},{"id":24707,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/battery-manufacturing-battery-development-csm-26009\/","url_meta":{"origin":8233,"position":1},"title":"\u96fb\u6c60\u88fd\u9020\u306b\u5411\u3051\u305f\u591a\u5c64\u96fb\u6975\u30b3\u30fc\u30c6\u30a3\u30f3\u30b0\u6280\u8853\u306e\u9032\u5c55","author":"LatB Staff","date":"2026\u5e742\u670824\u65e5","format":false,"excerpt":"\u9ad8\u5ea6\u306a\u96fb\u6975\u8a2d\u8a08\u3068\u3001\u305d\u308c\u304c\u96fb\u6c60\u96fb\u6975\u306e\u6027\u80fd\u304a\u3088\u3073\u52b9\u7387\u306b\u4e0e\u3048\u308b\u5f71\u97ff8inks \u5171\u540c\u5275\u696d\u8005\u517c CEO Dr.\u2026","rel":"","context":"\u5206\u6790\u30fb\u6e2c\u5b9a\u95a2\u9023","block_context":{"text":"\u5206\u6790\u30fb\u6e2c\u5b9a\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/analysis\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/02\/battery-manufacturing-battery-development-csm-26009_eyecatch.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/02\/battery-manufacturing-battery-development-csm-26009_eyecatch.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/02\/battery-manufacturing-battery-development-csm-26009_eyecatch.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/02\/battery-manufacturing-battery-development-csm-26009_eyecatch.jpg?resize=700%2C400&ssl=1 2x"},"classes":[]},{"id":24152,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/cell-culture-protein-expression-bid-ts-mbr-25074\/","url_meta":{"origin":8233,"position":2},"title":"\u30bf\u30f3\u30d1\u30af\u7523\u751f\u3084\u30a6\u30a4\u30eb\u30b9\u7523\u751f\u3092\u76ee\u7684\u3068\u3057\u305f\u9ad8\u5bc6\u5ea6\u7d30\u80de\u57f9\u990a\u30b7\u30b9\u30c6\u30e0\u5c0e\u5165\u306e\u7b2c\u4e00\u6b69\uff1a\u7d30\u80de\u682a\u306e\u7d99\u4ee3\u3068\u51cd\u7d50\u4fdd\u5b58\u7de8","author":"LatB Staff","date":"2025\u5e7412\u67083\u65e5","format":false,"excerpt":"\u9ad8\u5bc6\u5ea6\u7d30\u80de\u57f9\u990a\u30b7\u30b9\u30c6\u30e0\u3067\u306f\u3001\u5c02\u7528\u306e\u6d6e\u904a\u7d30\u80de\u682a\u3092\u7528\u3044\u3066\u6c7a\u3081\u3089\u308c\u305f\u624b\u9806\u3067\u57f9\u990a\u3057\u307e\u3059\u3002\u5b89\u5b9a\u7684\u306b\u904b\u7528\u3059\u308b\u305f\u3081\u2026","rel":"","context":"\u7d30\u80de\u57f9\u990a\u30fb\u30a4\u30e1\u30fc\u30b8\u30f3\u30b0","block_context":{"text":"\u7d30\u80de\u57f9\u990a\u30fb\u30a4\u30e1\u30fc\u30b8\u30f3\u30b0","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/cell\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/11\/cell-culture-protein-expression-bid-ts-mbr-25074_eycatch.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/11\/cell-culture-protein-expression-bid-ts-mbr-25074_eycatch.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/11\/cell-culture-protein-expression-bid-ts-mbr-25074_eycatch.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/11\/cell-culture-protein-expression-bid-ts-mbr-25074_eycatch.jpg?resize=700%2C400&ssl=1 2x"},"classes":[]},{"id":24545,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/digital-pcr-gene-expression-gsd-ts-sd-25082\/","url_meta":{"origin":8233,"position":3},"title":"\u3010Absolute Q\u30c7\u30b8\u30bf\u30ebPCR\u30b7\u30b9\u30c6\u30e0\u306e\u6d3b\u7528\u4f8b\u3011\u30df\u30c8\u30b3\u30f3\u30c9\u30ea\u30a2DNA\u306e\u5b9a\u91cf","author":"LatB Staff","date":"2026\u5e741\u670816\u65e5","format":false,"excerpt":"Applied Biosystems\u2122 QuantStudio\u2122 Absolute Q\u2122 \u30c7\u30b8\u30bf\u30ebP\u2026","rel":"","context":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","block_context":{"text":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/mol-bio\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/12\/digital-pcr-gene-expression-gsd-ts-sd-25082_eyecatch.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/12\/digital-pcr-gene-expression-gsd-ts-sd-25082_eyecatch.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/12\/digital-pcr-gene-expression-gsd-ts-sd-25082_eyecatch.jpg?resize=525%2C300&ssl=1 1.5x"},"classes":[]},{"id":25247,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/exosome-gene-expression-ts-r-25018\/","url_meta":{"origin":8233,"position":4},"title":"\u3010\u7b2c4\u56de\u3011&#8221;RNA cargo&#8221;\u306e\u7cbe\u88fd\u3068\u5b9a\u91cf\u89e3\u6790\uff5emiRNA\u306e\u5b9a\u91cf\u89e3\u6790\uff5e","author":"LatB Staff","date":"2026\u5e745\u670829\u65e5","format":false,"excerpt":"\u524d\u56de\uff08\u3010\u7b2c3\u56de\u3011\u201cRNA cargo\u201d\u306e\u7cbe\u88fd\u3068\u5b9a\u91cf\u89e3\u6790\uff09\u3067\u306f\u3001\u30a8\u30af\u30bd\u30bd\u30fc\u30e0 \uff08\u30a8\u30ad\u30bd\u30bd\u30fc\u30e0\uff09 \u304b\u3089\u306e\u2026","rel":"","context":"\u5206\u6790\u30fb\u6e2c\u5b9a\u95a2\u9023","block_context":{"text":"\u5206\u6790\u30fb\u6e2c\u5b9a\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/analysis\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25018_eyecatch-1.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25018_eyecatch-1.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25018_eyecatch-1.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25018_eyecatch-1.jpg?resize=700%2C400&ssl=1 2x"},"classes":[]},{"id":24647,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/sanger-seq-mutational-analysis-gsd-ts-ce-26007\/","url_meta":{"origin":8233,"position":5},"title":"\u30de\u30a4\u30ca\u30fc\u5909\u7570\u3092\u691c\u51fa\uff01Minor Variant Finder\u30bd\u30d5\u30c8\u30a6\u30a8\u30a2","author":"LatB Staff","date":"2026\u5e742\u67089\u65e5","format":false,"excerpt":"\u30ad\u30e3\u30d4\u30e9\u30ea\u30fc\u30b7\u30fc\u30b1\u30f3\u30b5\u3067\u306f\u300125%\u7a0b\u5ea6\u306e\u5272\u5408\u306e\u5909\u7570\u3092\u691c\u51fa\u3059\u308b\u3053\u3068\u304c\u3067\u304d\u307e\u3059\u304c\u3001\u3053\u308c\u3088\u308a\u3082\u4f4e\u3044\u5272\u5408\u306e\u5909\u2026","rel":"","context":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","block_context":{"text":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/mol-bio\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/01\/sanger-seq-mutational-analysis-gsd-ts-ce-26007_eyecatch.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/01\/sanger-seq-mutational-analysis-gsd-ts-ce-26007_eyecatch.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/01\/sanger-seq-mutational-analysis-gsd-ts-ce-26007_eyecatch.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/01\/sanger-seq-mutational-analysis-gsd-ts-ce-26007_eyecatch.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/01\/sanger-seq-mutational-analysis-gsd-ts-ce-26007_eyecatch.jpg?resize=1050%2C600&ssl=1 3x"},"classes":[]}],"jetpack_sharing_enabled":true,"amp_enabled":true,"jetpack_featured_media_url":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2021\/08\/shutterstock_1938816793-scaled.jpg","_links":{"self":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/posts\/8233","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/users\/975"}],"replies":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/comments?post=8233"}],"version-history":[{"count":0,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/posts\/8233\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/media\/9839"}],"wp:attachment":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/media?parent=8233"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/categories?post=8233"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/tags?post=8233"},{"taxonomy":"division","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/division?post=8233"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}