{"id":8443,"date":"2021-01-29T11:25:39","date_gmt":"2021-01-29T02:25:39","guid":{"rendered":"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/?p=8443"},"modified":"2024-07-04T13:13:02","modified_gmt":"2024-07-04T04:13:02","slug":"protein_expression_mb_bid_ts_1","status":"publish","type":"post","link":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/protein_expression_mb_bid_ts_1\/","title":{"rendered":"\u3042\u306a\u305f\u306e\u30bf\u30f3\u30d1\u30af\u8cea\u306b\u3068\u3063\u3066\u6700\u9069\u306a\u767a\u73fe\u7cfb\u306f\uff1f"},"content":{"rendered":"<h2>\u306f\u3058\u3081\u306b<\/h2>\n<p>\u7d44\u307f\u63db\u3048\u30bf\u30f3\u30d1\u30af\u8cea\u767a\u73fe\u306f\u3001\u591a\u304f\u306e\u7814\u7a76\u30d7\u30ed\u30b8\u30a7\u30af\u30c8\u306b\u304a\u3044\u3066\u6b20\u304b\u305b\u306a\u3044\u6280\u8853\u306e\u4e00\u3064\u3067\u3059\u3002\u54fa\u4e73\u985e\u7d30\u80de\u3001\u6606\u866b\u7d30\u80de\u3001\u9175\u6bcd\u3001\u5927\u8178\u83cc\u3092\u7528\u3044\u305f\u7cfb\u3001\u304a\u3088\u3073\u7121\u7d30\u80de\u767a\u73fe\u7cfb\u306a\u3069\u3055\u307e\u3056\u307e\u306a\u767a\u73fe\u7cfb\u304c\u958b\u767a\u3055\u308c\u3066\u3044\u307e\u3059\u304c\u3001\u3059\u3079\u3066\u306e\u30bf\u30f3\u30d1\u30af\u8cea\u3001\u30a2\u30d7\u30ea\u30b1\u30fc\u30b7\u30e7\u30f3\u306b\u6700\u9069\u306a\u767a\u73fe\u7cfb\u306f\u7121\u304f\u3001\u4f7f\u7528\u7528\u9014\u3001\u76ee\u7684\u30bf\u30f3\u30d1\u30af\u8cea\u306b\u5408\u308f\u305b\u3066\u4f7f\u3044\u5206\u3051\u308b\u5fc5\u8981\u304c\u3042\u308a\u307e\u3059\u3002<\/p>\n<p>\u4ee5\u4e0b\u306e\u8868\u306f\u5404\u767a\u73fe\u7cfb\u306e\u7279\u9577\u3001\u8ab2\u984c\u3092\u307e\u3068\u3081\u305f\u3082\u306e\u3067\u3059\u3002\u5b9f\u969b\u306b\u8a66\u3057\u3066\u307f\u306a\u3044\u3068\u308f\u304b\u3089\u306a\u3044\u3053\u3068\u3082\u3044\u307e\u3060\u591a\u304f\u3042\u308a\u307e\u3059\u304c\u3001\u6700\u9069\u306a\u767a\u73fe\u7cfb\u3092\u7d5e\u308a\u8fbc\u3080\u76ee\u5b89\u306b\u306a\u308b\u306f\u305a\u3067\u3059\u3002\u307e\u305f\u3001\u8868\u306e\u5f8c\u306b\u767a\u73fe\u7cfb\u3054\u3068\u306e\u73fe\u5728\u304a\u52e7\u3081\u306e\u88fd\u54c1\u3001\u304a\u3088\u3073\u95a2\u9023\u3059\u308b\u6280\u8853\u3092\u3054\u7d39\u4ecb\u3057\u307e\u3059\u306e\u3067\u4f75\u305b\u3066\u3054\u53c2\u7167\u304f\u3060\u3055\u3044\u3002<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter size-full wp-image-8463\" src=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2021\/01\/63a6631bb0826417be60b91a4e23ffdf.jpg\" alt=\"\" width=\"850\" height=\"557\" srcset=\"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2021\/01\/63a6631bb0826417be60b91a4e23ffdf.jpg 850w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2021\/01\/63a6631bb0826417be60b91a4e23ffdf-300x197.jpg 300w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2021\/01\/63a6631bb0826417be60b91a4e23ffdf-768x503.jpg 768w\" sizes=\"auto, (max-width: 850px) 100vw, 850px\" \/><\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter size-full wp-image-8448\" src=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2021\/01\/0161352a3d2ab457dfa6640c52a8eb52.jpg\" alt=\"\" width=\"850\" height=\"250\" \/><\/p>\n<h2>\u5404\u767a\u73fe\u7cfb\u306b\u3064\u3044\u3066\uff5e\u304a\u52e7\u3081\u306e\u88fd\u54c1\u60c5\u5831<\/h2>\n<h3>\u54fa\u4e73\u985e\u7d30\u80de\u767a\u73fe\u7cfb<\/h3>\n<p>\u7279\u306b\u54fa\u4e73\u985e\u7531\u6765\u30bf\u30f3\u30d1\u30af\u8cea\u306e\u767a\u73fe\u3067\u306f\u6d3b\u6027\u3092\u6301\u3064\u30bf\u30f3\u30d1\u30af\u8cea\u304c\u5f97\u3089\u308c\u308b\u53ef\u80fd\u6027\u304c\u3082\u3063\u3068\u3082\u9ad8\u3044\u3068\u8a00\u3048\u307e\u3059\u304c\u3001\u4e00\u822c\u7684\u306b\u30b3\u30b9\u30c8\u304c\u9ad8\u304f\u3001\u767a\u73fe\u30ec\u30d9\u30eb\u304c\u4f4e\u3044\u3053\u3068\u304c\u8ab2\u984c\u3067\u3059\u3002\u305f\u3060\u3057\u3001\u7dcf\u30bf\u30f3\u30d1\u30af\u8cea\u3042\u305f\u308a\u306e\u767a\u73fe\u91cf\u304c\u5c11\u306a\u3044\u305f\u3081\u7cbe\u88fd\u306b\u624b\u9593\u304c\u304b\u304b\u308a\u307e\u3059\u3002\u3064\u307e\u308a\u3001\u3044\u304b\u306b\u767a\u73fe\u30ec\u30d9\u30eb\u3092\u4e0a\u3052\u308b\u304b\u304c\u30dd\u30a4\u30f3\u30c8\u3068\u306a\u308a\u307e\u3059\u3002\u307e\u305a\u306f\u901a\u5e38\u9ad8\u767a\u73fe\u3092\u671b\u3081\u308b\u30d9\u30af\u30bf\u30fc\u306e\u9078\u629e\u304c\u809d\u8981\u3067\u3059\u3002\u73fe\u5728\u3001\u5f53\u793e\u3067\u306f\u4ee5\u4e0b\u306e\u30d9\u30af\u30bf\u30fc\u304c\u9ad8\u767a\u73fe\u3092\u671f\u5f85\u3067\u304d\u307e\u3059\u3002<\/p>\n<p><a href=\"https:\/\/www.thermofisher.com\/order\/catalog\/product\/A14697#\/A14697?CID=bid_clb_pex_r04_jp_cp1433_pjt7096_bid00000_0so_blg_op_awa_oc_s00_pe1_Social_LAB\" target=\"_blank\" rel=\"noopener\">pcDNA\u21223.4 TOPO\u2122 TA Cloning Kit<\/a><\/p>\n<p>\u307e\u305f\u3001\u6d6e\u904a\u57f9\u990a\u7cfb\u3067\u6bd4\u8f03\u7684\u9ad8\u767a\u73fe\u306a\u30b7\u30b9\u30c6\u30e0\u304c\u51fa\u59cb\u3081\u3066\u3044\u307e\u3059\uff08\u6297\u4f53\u3092g\/L\u30b9\u30b1\u30fc\u30eb\uff09\u3002\u6d6e\u904a\u7d30\u80de\u7528\u306e\u8a2d\u5099\u3092\u6e96\u5099\u3057\u3066\u3044\u305f\u3060\u304f\u5fc5\u8981\u304c\u3042\u308a\u307e\u3059\u304c\u3001\u305c\u3072\u4e00\u5ea6\u304a\u8a66\u3057\u304f\u3060\u3055\u3044\u3002<\/p>\n<p><a href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/life-science\/protein-biology\/protein-expression\/mammalian-protein-expression\/transient-mammalian-protein-expression\/expi293-expression-system.html?CID=bid_clb_pex_r04_jp_cp1433_pjt7096_bid00000_0so_blg_op_awa_oc_s00_pe1_Social_LAB\" target=\"_blank\" rel=\"noopener\">Gibco\u2122 Expi293\u2122Expression System<\/a><br \/>\n<a href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/life-science\/protein-biology\/protein-expression\/mammalian-protein-expression\/transient-mammalian-protein-expression\/expicho-expression-system.html?CID=bid_clb_pex_r04_jp_cp1433_pjt7096_bid00000_0so_blg_op_awa_oc_s00_pe1_Social_LAB\" target=\"_blank\" rel=\"noopener\">Gibco\u2122 ExpiCHO\u2122 Expression System<\/a><\/p>\n<p>\u307e\u305f\u3001\u54fa\u4e73\u985e\u7d30\u80de\u767a\u73fe\u7cfb\u306f\u7cd6\u9396\u4ed8\u52a0\u304c\u8d77\u3053\u308b\u3053\u3068\u304c\u30e1\u30ea\u30c3\u30c8\u306e\u4e00\u3064\u3067\u3059\u304c\u3001\u69cb\u9020\u89e3\u6790\u3092\u884c\u3046\u5834\u5408\u306b\u90aa\u9b54\u306b\u306a\u308b\u3053\u3068\u3082\u3042\u308b\u3068\u601d\u3044\u307e\u3059\u3002\u305d\u3093\u306a\u5834\u5408\u306f<a href=\"https:\/\/www.thermofisher.com\/order\/catalog\/product\/A39240#\/A39240?CID=bid_clb_pex_r04_jp_cp1433_pjt7096_bid00000_0so_blg_op_awa_oc_s00_pe1_Social_LAB\" target=\"_blank\" rel=\"noopener\">Gibco\u2122 Expi293F\u2122 GnTI- Cells<\/a>\u3092\u3054\u691c\u8a0e\u304f\u3060\u3055\u3044\u3002<\/p>\n<h3>\u6606\u866b\u7d30\u80de\u767a\u73fe\u7cfb<\/h3>\n<p>\u54fa\u4e73\u985e\u7d30\u80de\u767a\u73fe\u7cfb\u306b\u6b21\u3044\u3067\u9ad8\u6d3b\u6027\u306e\u30bf\u30f3\u30d1\u30af\u8cea\u304c\u5f97\u3089\u308c\u3001\u304b\u3064\u3001\u3046\u307e\u304f\u3044\u3051\u3070\u767a\u73fe\u30ec\u30d9\u30eb\u304c\u9ad8\u3044\u3068\u3044\u3046\u5229\u70b9\u304c\u3042\u308a\u307e\u3059\u3002\u3057\u304b\u3057\u3001\u901a\u5e38\u30d0\u30ad\u30e5\u30ed\u30a6\u30a4\u30eb\u30b9\u3092\u4f7f\u7528\u3059\u308b\u305f\u3081\u3001\u305d\u306e\u624b\u9593\u3068\u6642\u9593\u304c\u554f\u984c\u3068\u8003\u3048\u3089\u308c\u308b\u65b9\u304c\u591a\u3044\u306e\u3067\u306f\u306a\u3044\u3067\u3057\u3087\u3046\u304b\u3002\u4ee5\u4e0b\u306e\u88fd\u54c1\u3082\u30d0\u30ad\u30e5\u30ed\u30a6\u30a4\u30eb\u30b9\u3092\u4f7f\u7528\u3057\u3066\u3044\u307e\u3059\u304c\u3001\u5404\u30b9\u30c6\u30c3\u30d7\u306e\u52b9\u7387\u3092\u4e0a\u3052\u308b\u3053\u3068\u306b\u3088\u308a\u30a6\u30a4\u30eb\u30b9\u5897\u5e45\u30b9\u30c6\u30c3\u30d7\u3092\u7701\u304d\u3001\u6700\u77ed1\u9031\u9593\u7a0b\u5ea6\u3067\u30bf\u30f3\u30d1\u30af\u8cea\u767a\u73fe\u3092\u884c\u3046\u3053\u3068\u304c\u3067\u304d\u307e\u3059\u3002<\/p>\n<p><a href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/life-science\/protein-biology\/protein-expression\/insect-protein-expression\/expisf-expression-system.html?CID=bid_clb_pex_r04_jp_cp1433_pjt7096_bid00000_0so_blg_op_awa_oc_s00_pe1_Social_LAB\" target=\"_blank\" rel=\"noopener\">Gibco\u2122 ExpiSf9\u2122 Baculovirus Expression System<\/a><br \/>\n\u203b\u5404\u793e\u30d0\u30ad\u30e5\u30ed\u30a6\u30a4\u30eb\u30b9\u306e\u30b2\u30ce\u30e0DNA\u3067\u3042\u308bBacmid\u4f5c\u6210\u65b9\u6cd5\u3092\u5de5\u592b\u3057\u3066\u3044\u307e\u3059\u304c\u3001\u4e0a\u8a18\u30b7\u30b9\u30c6\u30e0\u3067\u306f\u5c02\u7528\u306e\u5927\u8178\u83cc\u5185\u3067Bacmid\u4f5c\u6210\u3092\u884c\u3046\u3001Bac-to-Bac\u2122\u30b7\u30b9\u30c6\u30e0\u3092\u63a1\u7528\u3057\u3066\u3044\u307e\u3059\u3002<br \/>\n\u3061\u306a\u307f\u306b\u30d0\u30ad\u30e5\u30ed\u30a6\u30a4\u30eb\u30b9\u3092\u4f7f\u7528\u3057\u306a\u3044\u7cfb\u3082\u3042\u308a\u307e\u3059\u3002\u767a\u73fe\u30ec\u30d9\u30eb\u306f\u4e00\u822c\u7684\u306b\u30d0\u30ad\u30e5\u30ed\u30a6\u30a4\u30eb\u30b9\u3092\u4f7f\u7528\u3057\u305f\u6642\u3088\u308a\u3082\u4f4e\u304f\u306a\u308a\u307e\u3059\u304c\u3001\u54fa\u4e73\u985e\u7d30\u80de\u767a\u73fe\u7cfb\u3068\u540c\u3058\u3088\u3046\u306b\u30c8\u30e9\u30f3\u30b9\u30d5\u30a7\u30af\u30b7\u30e7\u30f3\u306b\u3088\u308a\u4e00\u904e\u6027\u3001\u5b89\u5b9a\u767a\u73fe\u304c\u53ef\u80fd\u3067\u3059\u3002<\/p>\n<p><a href=\"https:\/\/www.thermofisher.com\/order\/catalog\/product\/K81001#\/K81001?CID=bid_clb_pex_r04_jp_cp1433_pjt7096_bid00000_0so_blg_op_awa_oc_s00_pe1_Social_LAB\" target=\"_blank\" rel=\"noopener\">Invitrogen\u2122 InsectSelect\u2122\u30b7\u30b9\u30c6\u30e0<\/a>\uff08Sf9\u7d30\u80de\u306a\u3069\u4f7f\u7528\uff09<\/p>\n<h3>\u9175\u6bcd\u767a\u73fe\u7cfb<\/h3>\n<p>\u5358\u7d30\u80de\u751f\u7269\u3067\u3059\u304c\u771f\u6838\u751f\u7269\u3067\u3059\u306e\u3067\u3001\u5c0f\u80de\u4f53\u3092\u6301\u3064\u305f\u3081\u5206\u6ccc\u767a\u73fe\u304c\u884c\u3048\u307e\u3059\u3002<strong>\u4e3b\u306bSaccharomyces cerevisiae\u3092\u4f7f\u3063\u305f\u7cfb\u3068Pichia pastoris\u3092\u4f7f\u3063\u305f\u7cfb\u304c\u3042\u308a\u307e\u3059\u304c\u3001\u30bf\u30f3\u30d1\u30af\u8cea\u306e\u5927\u91cf\u767a\u73fe\u306b\u306f\u4e3b\u306b\u5f8c\u8005\uff08Pichia\uff09\u304c\u4f7f\u7528\u3055\u308c\u307e\u3059\u3002<\/strong>\u5927\u8178\u83cc\u3088\u308a\u306f\u5c11\u3057\u624b\u9593\u304c\u304b\u304b\u308a\u307e\u3059\u304c\u3001Pichia\u3060\u3068\u304b\u306a\u308a\u9ad8\u767a\u73fe\u3082\u671f\u5f85\u3067\u304d\u307e\u3059\u3002\u9175\u6bcd\u306e\u5834\u5408\u3001\u7d44\u307f\u63db\u3048\u4f53\u306e\u9078\u5225\u306b\u6804\u990a\u8981\u6c42\u6027\u3092\u5229\u7528\u3059\u308b\u3053\u3068\u304c\u591a\u304f\u305d\u306e\u5834\u5408\u6700\u5c0f\u57f9\u5730\u3092\u4f7f\u7528\u3059\u308b\u5fc5\u8981\u304c\u3042\u308a\u307e\u3059\u304c\u3001\u5927\u8178\u83cc\u3068\u540c\u69d8\u306b\u6297\u751f\u7269\u8cea\u8010\u6027\u3067\u9078\u5225\u3059\u308b\u30b7\u30b9\u30c6\u30e0\u3082\u6e96\u5099\u3055\u308c\u3066\u3044\u307e\u3059\u3002<\/p>\n<p><a href=\"https:\/\/www.thermofisher.com\/order\/catalog\/product\/K174001#\/K174001?CID=bid_clb_pex_r04_jp_cp1433_pjt7096_bid00000_0so_blg_op_awa_oc_s00_pe1_Social_LAB\" target=\"_blank\" rel=\"noopener\">Invitrogen\u2122 EasySelect\u2122 Pichia Expression Kit<\/a><\/p>\n<h3>\u5927\u8178\u83cc\u767a\u73fe\u7cfb<\/h3>\n<p>\u3068\u306b\u304b\u304f\u5b89\u4fa1\u3067\u9ad8\u767a\u73fe\u3067\u304d\u308b\u53ef\u80fd\u6027\u304c\u3042\u308b\u306e\u3067\u3001\u307e\u305a\u306f\u4e00\u5ea6\u8a66\u3057\u3066\u307f\u308b\u4fa1\u5024\u304c\u3042\u308b\u3068\u601d\u3044\u307e\u3059\u3002\u307e\u305f\u3001\u4e0d\u6eb6\u5316\u3057\u3066\u3082\u3044\u3044\u5834\u5408\u306a\u3069\u306f\u6700\u9069\u3060\u3068\u601d\u308f\u308c\u307e\u3059\u3002\u305f\u3060\u3057\u3001\u30ea\u30d5\u30a9\u30fc\u30eb\u30c7\u30a3\u30f3\u30b0\u306b\u3088\u308a\u5c01\u5165\u4f53\u3092\u53ef\u6eb6\u5316\u3059\u308b\u3053\u3068\u3082\u53ef\u80fd\u306a\u5834\u5408\u3082\u3042\u308a\u307e\u3059\u3002<\/p>\n<p><a href=\"https:\/\/www.thermofisher.com\/order\/catalog\/product\/89867#\/89867?CID=bid_clb_pex_r04_jp_cp1433_pjt7096_bid00000_0so_blg_op_awa_oc_s00_pe1_Social_LAB\" target=\"_blank\" rel=\"noopener\">Thermo Scientific\u2122 Pierce\u2122 Protein Refolding Kit<\/a><\/p>\n<p>\u306a\u304a\u3001\u819c\u30bf\u30f3\u30d1\u30af\u8cea\u306e\u3088\u3046\u306b\u3082\u3068\u3082\u3068\u4e0d\u6eb6\u6027\u306e\u3082\u306e\u3001\u304a\u3088\u3073\u5206\u6ccc\u30bf\u30f3\u30d1\u30af\u8cea\u306a\u3069\u306b\u306f\u901a\u5e38\u4e0d\u5411\u304d\u3067\u3059\uff08\u4e00\u90e8\u30d9\u30af\u30bf\u30fc\u3067\u306f\u53ef\u80fd\u306a\u5834\u5408\u3082\u3042\u308a\u307e\u3059\uff09\u304c\u3001\u7d30\u80de\u8cea\u5c40\u5728\u306e\u53ef\u6eb6\u6027\u30bf\u30f3\u30d1\u30af\u8cea\u306e\u5834\u5408\u3001\u8a66\u3057\u3066\u307f\u308b\u4fa1\u5024\u304c\u5341\u5206\u3042\u308b\u3068\u601d\u3044\u307e\u3059\u3002<br \/>\n\u3055\u307e\u3056\u307e\u306a\u30e1\u30fc\u30ab\u30fc\u304b\u3089\u540c\u3058\u3088\u3046\u306a\u30b7\u30b9\u30c6\u30e0\u304c\u8ca9\u58f2\u3055\u308c\u3066\u3044\u307e\u3059\u304c\u3001IPTG\u8a98\u5c0e\u3092\u304b\u3051\u308b\u524d\u304b\u3089\u767a\u73fe\u3057\u3066\u3057\u307e\u3046\u554f\u984c\u3067\u3001\u767a\u73fe\u30bf\u30f3\u30d1\u30af\u8cea\u306e\u4e0d\u6eb6\u5316\u3001\u6bd2\u6027\u306b\u3088\u308b\u53ce\u91cf\u4f4e\u4e0b\u306e\u539f\u56e0\u306b\u306a\u308b\u8a98\u5c0e\u6f0f\u308c\u306e\u554f\u984c\u3092\u89e3\u6d88\u3067\u304d\u308bBL21-AI\u2122\u682a\u306b\u3064\u3044\u3066\u306f\u4e00\u8003\u306e\u4fa1\u5024\u304c\u3042\u308b\u3068\u601d\u3044\u307e\u3059\uff08\u30a2\u30e9\u30d3\u30ce\u30fc\u30b9\u8a98\u5c0e\u7cfb\u3092\u4f7f\u7528\u3057\u3066\u3044\u307e\u3059\u304c\u3001\u4e00\u822c\u7684\u306apET\u7cfb\u30d9\u30af\u30bf\u30fc\u3092\u4f7f\u7528\u53ef\u80fd\u3067\u3059\uff09\u3002<\/p>\n<p><a href=\"https:\/\/www.thermofisher.com\/order\/catalog\/product\/C607003#\/C607003?CID=bid_clb_pex_r04_jp_cp1433_pjt7096_bid00000_0so_blg_op_awa_oc_s00_pe1_Social_LAB\" target=\"_blank\" rel=\"noopener\">Invitrogen\u2122 BL21-AI\u2122 One Shot\u2122 Chemically Competent E. coli<\/a><\/p>\n<p>\u306a\u304a\u3001\u4e00\u822c\u7684\u306b\u306f\u30bf\u30b0\u7121\u3057\u3088\u308a\u306f\u3001\u77ed\u3044\u3082\u306e\u3067\u3082N\u672b\u7aef\u5074\u306b\u4ed8\u3051\u305f\u65b9\u304c\u767a\u73fe\u6210\u529f\u7387\u306f\u9ad8\u3044\u3088\u3046\u3067\u3059\u3002\u5f53\u793eGateway\u30b7\u30b9\u30c6\u30e0\u3092\u4f7f\u3048\u3070\u5404\u7a2e\u30bf\u30b0\u3068\u306e\u76f8\u6027\u3092\u8abf\u3079\u308b\u306e\u306b\u4fbf\u5229\u3067\u3059\uff08\u305d\u306e\u4ed6\u306e\u95a2\u9023\u6280\u8853\u53c2\u7167\uff09\u3002\u307e\u305f\u3001\u4eba\u5de5\u907a\u4f1d\u5b50\u5408\u6210\u3092\u5229\u7528\u3057\u3001\u30b3\u30c9\u30f3\u306e\u6700\u9069\u5316\u3092\u884c\u3046\u306e\u3082\u9ad8\u53ce\u91cf\u3092\u5f97\u308b\u305f\u3081\u306b\u306f\u6709\u52b9\u306a\u5834\u5408\u304c\u591a\u3044\u3088\u3046\u3067\u3059\uff08\u305d\u306e\u4ed6\u306e\u95a2\u9023\u6280\u8853\u53c2\u7167\uff09\u3002<\/p>\n<h3>\u85fb\u985e\u767a\u73fe\u7cfb<\/h3>\n<p>\u30bf\u30f3\u30d1\u30af\u8cea\u3092\u5927\u91cf\u306b\u4f5c\u308a\u305f\u3044\u5834\u5408\u306b\u4f7f\u7528\u3055\u308c\u308b\u30b1\u30fc\u30b9\u306f\u5c11\u306a\u304f\u3001\u5149\u5408\u6210\u306a\u3069\u3001\u690d\u7269\u7279\u6709\u306e\u6a5f\u80fd\u306b\u95a2\u3059\u308b\u7814\u7a76\u306b\u30e2\u30c7\u30eb\u751f\u7269\u3068\u3057\u3066\u4f7f\u7528\u3055\u308c\u308b\u306e\u304c\u307b\u3068\u3093\u3069\u3060\u3068\u601d\u308f\u308c\u307e\u3059\u3002\u305d\u306e\u4ed6\u30d0\u30a4\u30aa\u71c3\u6599\u958b\u767a\u306e\u30d1\u30a4\u30ed\u30c3\u30c8\u5b9f\u9a13\u306b\u4f7f\u7528\u3055\u308c\u308b\u3053\u3068\u3082\u3042\u308a\u305d\u3046\u3067\u3059\u3002<br \/>\n\u5f53\u793e\u306f\u3082\u3063\u3068\u3082\u3088\u304f\u4f7f\u7528\u3055\u308c\u3066\u3044\u308b\u682a\u306e\u4e00\u3064\u3067\u3042\u308b\u3001<a href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/life-science\/protein-biology\/protein-expression\/algal-protein-expression.html?CID=bid_clb_pex_r04_jp_cp1433_pjt7096_bid00000_0so_blg_op_awa_oc_s00_pe1_Social_LAB\" target=\"_blank\" rel=\"noopener\">\u30e9\u30f3\u85fbSynechococcus elongatus\u304a\u3088\u3073\u30af\u30e9\u30df\u30c9\u30e2\u30ca\u30b9Chlamydomonas reinhardtii 137c\u3067\u4f7f\u7528\u53ef\u80fd\u306a\u57f9\u5730\u3068\u30d9\u30af\u30bf\u30fc<\/a>\u306e\u8ca9\u58f2\u3092\u884c\u3063\u3066\u3044\u307e\u3059\u3002<\/p>\n<p>\u306a\u304a\u3001\u54fa\u4e73\u985e\u7531\u6765\u306e\u907a\u4f1d\u5b50\u3092\u767a\u73fe\u3055\u305b\u308b\u5834\u5408\u306f\u3001\u5869\u57fa\u914d\u5217\u306e\u6700\u9069\u5316\u304c\u6709\u52b9\u306a\u5834\u5408\u304c\u591a\u3044\u3088\u3046\u3067\u3059\u3002\u4eba\u5de5\u907a\u4f1d\u5b50\u5408\u6210\u3092\u5229\u7528\u3057\u3001\u30b3\u30c9\u30f3\u306e\u6700\u9069\u5316\u3092\u884c\u3046\u306e\u3082\u9ad8\u53ce\u91cf\u3092\u5f97\u308b\u305f\u3081\u306b\u306f\u6709\u52b9\u306a\u5834\u5408\u304c\u591a\u3044\u3088\u3046\u3067\u3059\uff08\u305d\u306e\u4ed6\u306e\u95a2\u9023\u6280\u8853\u53c2\u7167\uff09\u3002<\/p>\n<h3>\u7121\u7d30\u80de\u767a\u73fe\u7cfb<\/h3>\n<p>\u30cf\u30a4\u30b3\u30b9\u30c8\u3067\u3042\u308b\u3053\u3068\u306f\u5909\u308f\u308a\u3042\u308a\u307e\u305b\u3093\u304c\u3001\u6bd4\u8f03\u7684\u9ad8\u767a\u73fe\u304c\u671f\u5f85\u3067\u304d\u308b\u30b7\u30b9\u30c6\u30e0\u3068\u3057\u3066\u3001\u5927\u8178\u83cc\u3001\u5c0f\u9ea6\u80da\u82bd\u3001\u54fa\u4e73\u985e\u7d30\u80de\u3001\u6606\u866b\u7d30\u80de\u3092\u4f7f\u3063\u305f\u7cfb\u304c\u958b\u767a\u3055\u308c\u3066\u3044\u307e\u3059\u3002\u7279\u306b\u69cb\u9020\u89e3\u6790\u7528\u306b\u5b89\u5b9a\u540c\u4f4d\u4f53\u306a\u3069\u306e\u30e9\u30d9\u30eb\u3092\u5165\u308c\u3089\u308c\u305f\u3044\u5834\u5408\u306b\u306f\u691c\u8a0e\u3055\u308c\u308b\u4fa1\u5024\u304c\u3042\u308b\u3068\u601d\u3044\u307e\u3059\u3002\u307e\u305f\u300196 well\u30d7\u30ec\u30fc\u30c8\u306a\u3069\u3067\u3082\u884c\u3048\u3066\u3001\u57fa\u672c\u7684\u306b\u77ed\u6642\u9593\u3067\u5b8c\u4e86\u3059\u308b\u305f\u3081\u3001\u30cf\u30a4\u30b9\u30eb\u30fc\u30d7\u30c3\u30c8\u30d5\u30ec\u30f3\u30c9\u30ea\u30fc\u306a\u767a\u73fe\u7cfb\u3060\u3068\u8a00\u3048\u307e\u3059\u3002\u307e\u305f\u3001\u767a\u73fe\u81ea\u4f53\u306f\u7d44\u307f\u63db\u3048\u5b9f\u9a13\u306b\u306f\u3042\u305f\u308a\u307e\u305b\u3093\u3002\u5de5\u592b\u3059\u308c\u3070\u5168\u884c\u7a0b\u3092\u975e\u7d44\u307f\u63db\u3048\u5b9f\u9a13\u3068\u3057\u3066\u884c\u3046\u3053\u3068\u3082\u53ef\u80fd\u3067\u3059\u3002<br \/>\n\u5f53\u793e\u3067\u306f\u5927\u8178\u83cc\u304a\u3088\u3073\u54fa\u4e73\u985e\u7d30\u80de\u7531\u6765\u306e\u62bd\u51fa\u6db2\u3092\u4f7f\u7528\u3057\u305f\u7cfb\u3092\u8ca9\u58f2\u3057\u3066\u3044\u307e\u3059\u3002\u3084\u306f\u308a\u54fa\u4e73\u985e\u7531\u6765\u306e\u30bf\u30f3\u30d1\u30af\u8cea\u306e\u767a\u73fe\u306b\u306f\u54fa\u4e73\u985e\u7531\u6765\u306e\u7cfb\u306e\u65b9\u304c\u76f8\u6027\u306f\u3044\u3044\u3088\u3046\u3067\u3059\u3002<\/p>\n<p>\u5927\u8178\u83cc\u7121\u7d30\u80de\u767a\u73fe\u7cfb\uff1a<a href=\"https:\/\/www.thermofisher.com\/order\/catalog\/product\/K990100#\/K990100?CID=bid_clb_pex_r04_jp_cp1433_pjt7096_bid00000_0so_blg_op_awa_oc_s00_pe1_Social_LAB\" target=\"_blank\" rel=\"noopener\">Invitrogen\u2122 Expressway\u2122 Cell-Free Expression System<\/a><br \/>\n\u54fa\u4e73\u985e\u7121\u7d30\u80de\u767a\u73fe\u7cfb\uff1a<a href=\"https:\/\/www.thermofisher.com\/order\/catalog\/product\/88881#\/88881?CID=bid_clb_pex_r04_jp_cp1433_pjt7096_bid00000_0so_blg_op_awa_oc_s00_pe1_Social_LAB\" target=\"_blank\" rel=\"noopener\">Thermo Scientific\u2122 1-Step Human Coupled IVT Kit \u2013 DNA<\/a><\/p>\n<h2><\/h2>\n<h2>\u305d\u306e\u4ed6\u306e\u95a2\u9023\u6280\u8853<\/h2>\n<p>\u5b9f\u9a13\u3092\u59cb\u3081\u308b\u969b\u3001\u307e\u305a\u306f\u3069\u306e\u3088\u3046\u306a\u767a\u73fe\u30d9\u30af\u30bf\u30fc\u3092\u4f7f\u7528\u3059\u308b\u304b\u3092\u8003\u3048\u308b\u5fc5\u8981\u304c\u3042\u308a\u307e\u3059\u3002\u305d\u306e\u969b\u3001\u4ee5\u4e0b\u306e\u691c\u7d22\u30b5\u30a4\u30c8\u304c\u4fbf\u5229\u3067\u3059\u3002<\/p>\n<p><a href=\"https:\/\/igene.thermofisher.com\/products\/selector\/vectors?CID=bid_clb_pex_r04_jp_cp1433_pjt7096_bid00000_0so_blg_op_awa_oc_s00_pe1_Social_LAB\" target=\"_blank\" rel=\"noopener\">Vector Selection Tool<\/a><\/p>\n<p>\u767a\u73fe\u30d9\u30af\u30bf\u30fc\u306e\u6e96\u5099\u306b\u306f\u30af\u30ed\u30fc\u30cb\u30f3\u30b0\u6280\u8853\u304c\u5fc5\u8981\u3067\u3059\u3002\u3053\u308c\u304b\u3089\u59cb\u3081\u3089\u308c\u308b\u65b9\u306b\u306f\u4ee5\u4e0b\u30cf\u30f3\u30ba\u30aa\u30f3\u30c8\u30ec\u30fc\u30cb\u30f3\u30b0\u304c\u304a\u52e7\u3081\u3067\u3059\u3002<\/p>\n<p><a href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/technical-resources\/trainings\/lifescience-training.html#t3?CID=bid_clb_pex_r04_jp_cp1433_pjt7096_bid00000_0so_blg_op_awa_oc_s00_pe1_Social_LAB\" target=\"_blank\" rel=\"noopener\">\u521d\u3081\u3066\u306e\u30af\u30ed\u30fc\u30cb\u30f3\u30b0\u30cf\u30f3\u30ba\u30aa\u30f3\u30c8\u30ec\u30fc\u30cb\u30f3\u30b0<\/a><\/p>\n<p>\u307e\u305f\u3001\u4e00\u304b\u3089\u8a66\u85ac\u306a\u3069\u3092\u305d\u308d\u3048\u308b\u5fc5\u8981\u304c\u3042\u308b\u5834\u5408\u306a\u3069\u3001\u4eba\u5de5\u907a\u4f1d\u5b50\u5408\u6210\u3067\u767a\u73fe\u30d9\u30af\u30bf\u30fc\u3092\u4f5c\u3063\u3066\u3057\u307e\u3046\u306e\u3082\u4e00\u624b\u3067\u3059\u3002\u5f53\u793e\u306e\u591a\u304f\u306e\u30d9\u30af\u30bf\u30fc\u306f\u672c\u30b5\u30fc\u30d3\u30b9\u3067\u306f\u7121\u511f\u3067\uff08\u30af\u30ed\u30fc\u30cb\u30f3\u30b0\u4ee3\u306f\u5fc5\u8981\uff09\u3054\u5229\u7528\u3044\u305f\u3060\u3051\u307e\u3059\u306e\u3067\u4fbf\u5229\u3067\u3059\u3002\u307e\u305f\u3001<a href=\"http:\/\/&lt;a href=&quot;mailto:jptech@thermofisher.com&quot;&gt;\u30c6\u30af\u30cb\u30ab\u30eb\u30b5\u30dd\u30fc\u30c8&lt;\/a&gt;\">\u30c6\u30af\u30cb\u30ab\u30eb\u30b5\u30dd\u30fc\u30c8<\/a>\u3078\u304a\u554f\u3044\u5408\u308f\u305b\u3044\u305f\u3060\u3051\u308c\u3070\u9069\u5207\u306a\u30d9\u30af\u30bf\u30fc\u306e\u9078\u3073\u65b9\u306a\u3069\u3054\u6848\u5185\u53ef\u80fd\u3067\u3059\u3002<\/p>\n<p><a href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/life-science\/cloning\/gene-synthesis.html?CID=bid_clb_pex_r04_jp_cp1433_pjt7096_bid00000_0so_blg_op_awa_oc_s00_pe1_Social_LAB\" target=\"_blank\" rel=\"noopener\">GeneArt\u907a\u4f1d\u5b50\u5408\u6210\u30b5\u30fc\u30d3\u30b9<\/a><\/p>\n<p>\u3055\u3089\u306b\u3001\u7279\u306b\u5019\u88dc\u907a\u4f1d\u5b50\u306e\u7531\u6765\u751f\u7269\u3068\u767a\u73fe\u7528\u306e\u30db\u30b9\u30c8\u751f\u7269\u304c\u9032\u5316\u7684\u306b\u96e2\u308c\u3066\u3044\u308b\u5834\u5408\u306a\u3069\u3001\u6700\u9069\u5316\u304c\u975e\u5e38\u306b\u6709\u52b9\u306a\u5834\u5408\u304c\u3042\u308a\u307e\u3059\u3002\u30d2\u30c8\u306e\u907a\u4f1d\u5b50\u3092\u5927\u8178\u83cc\u3084\u85fb\u985e\u306a\u3069\u3067\u767a\u73fe\u3055\u305b\u308b\u5834\u5408\u306f\u6700\u9069\u5316\u3092\u884c\u3046\u305f\u3081\u306b\u907a\u4f1d\u5b50\u3092\u4eba\u5de5\u5408\u6210\u3059\u308b\u3068\u3044\u3046\u3053\u3068\u3082\u3042\u308a\u307e\u3059\u3002\u307e\u305f\u3001\u610f\u5916\u3068\u30d2\u30c8\u306e\u907a\u4f1d\u5b50\u3092\u30d2\u30c8\u306e\u7d30\u80de\u3067\u767a\u73fe\u3055\u305b\u308b\u5834\u5408\u3067\u3082\u6700\u9069\u5316\u306b\u3088\u308a\u767a\u73fe\u91cf\u304c\u5897\u3048\u308b\u3053\u3068\u304c\u3042\u308a\u307e\u3059\u3002<\/p>\n<p><a href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/life-science\/cloning\/gene-synthesis\/geneart-gene-synthesis\/geneoptimizer.html?CID=bid_clb_pex_r04_jp_cp1433_pjt7096_bid00000_0so_blg_op_awa_oc_s00_pe1_Social_LAB\" target=\"_blank\" rel=\"noopener\">GeneArt\u2122 GeneOptimizer\u2122<\/a><\/p>\n<p>\u3084\u306f\u308a\u3069\u306e\u767a\u73fe\u7cfb\u304c\u6700\u9069\u5316\u306f\u8a66\u3057\u3066\u307f\u306a\u3044\u3068\u308f\u304b\u3089\u306a\u3044\u3053\u3068\u304c\u3042\u308a\u307e\u3059\u3002\u5927\u8178\u83cc\u767a\u73fe\u7cfb\u3067\u306f\u4e0d\u6eb6\u5316\u3057\u3066\u3057\u307e\u3044\u3001\u30bf\u30b0\u3092\u8907\u6570\u7a2e\u985e\u8a66\u3059\u5fc5\u8981\u304c\u3042\u308b\u3001\u3042\u308b\u3044\u306f\u5927\u8178\u83cc\u3092\u3042\u304d\u3089\u3081\u3066\u54fa\u4e73\u985e\u7d30\u80de\u767a\u73fe\u7cfb\u3092\u8a66\u3059\u306a\u3069\u3002Gateway\u30c6\u30af\u30ce\u30ed\u30b8\u30fc\u3092\u5229\u7528\u3059\u308c\u3070\u3001\u5bfe\u8c61\u907a\u4f1d\u5b50\u306e\u4ed6\u306e\u767a\u73fe\u30d9\u30af\u30bf\u30fc\u3078\u306e\u4e57\u305b\u63db\u3048\u3092\u7c21\u4fbf\u306b\u884c\u3048\u307e\u3059\u3002<\/p>\n<p><a href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/life-science\/cloning\/gateway-cloning.html?CID=bid_clb_pex_r04_jp_cp1433_pjt7096_bid00000_0so_blg_op_awa_oc_s00_pe1_Social_LAB\" target=\"_blank\" rel=\"noopener\">Gateway\u30c6\u30af\u30ce\u30ed\u30b8\u30fc<\/a><\/p>\n<p>\u6700\u5f8c\u306b\u3001\u5b9f\u9a13\u306b\u4f7f\u7528\u3059\u308b\u7d44\u307f\u63db\u3048\u30bf\u30f3\u30d1\u30af\u8cea\u3092\u767a\u73fe\u3059\u308b\u30b5\u30fc\u30d3\u30b9\u3082\u3054\u3056\u3044\u307e\u3059\u3002<\/p>\n<p><a href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/products-and-services\/services\/custom-services\/protein-expression-services.html#guide?CID=bid_clb_pex_r04_jp_cp1433_pjt7096_bid00000_0so_blg_op_awa_oc_s00_pe1_Social_LAB\" target=\"_blank\" rel=\"noopener\">\u30bf\u30f3\u30d1\u30af\u8cea\u767a\u73fe\u53d7\u8a17\u30b5\u30fc\u30d3\u30b9<\/a><\/p>\n<p>\u305d\u306e\u4ed6\u3054\u4e0d\u660e\u70b9\u306a\u70b9\u306f\u304a\u6c17\u8efd\u306b<a href=\"mailto:jptech@thermofisher.com\">\u30c6\u30af\u30cb\u30ab\u30eb\u30b5\u30dd\u30fc\u30c8<\/a>\u307e\u3067\u3054\u9023\u7d61\u304f\u3060\u3055\u3044\u3002<br \/>\nTel: 0120-477-392\uff08\u30c0\u30a4\u30ec\u30af\u30c8\u756a\u53f76\uff09<\/p>\n<h2>\u3010\u7121\u6599\u516c\u958b\u4e2d\u3011Protein Expression\u30cf\u30f3\u30c9\u30d6\u30c3\u30af<\/h2>\n<p>\u30bf\u30f3\u30d1\u30af\u767a\u73fe\u306e\u5b9f\u9a13\u3092\u691c\u8a0e\u3057\u3066\u3044\u308b\u65b9\u3084\u3001\u8a73\u7d30\u60c5\u5831\u3092\u78ba\u8a8d\u3057\u305f\u3044\u65b9\u306b\u3046\u3063\u3066\u3064\u3051\u306e\u30cf\u30f3\u30c9\u30d6\u30c3\u30af\u3067\u3059\u3002<\/p>\n<p><a class=\"btn btn-red\" href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/global\/forms\/protein-expression-handbook-download.html?CID=bid_clb_pex_r04_jp_cp1433_pjt7096_bid00000_0so_blg_op_awa_oc_s00_pe1_Social_LAB\" target=\"_blank\" rel=\"noopener noreferrer\">\u30c0\u30a6\u30f3\u30ed\u30fc\u30c9\u3059\u308b<\/a><\/p>\n<p>\u7814\u7a76\u7528\u306b\u306e\u307f\u4f7f\u7528\u3067\u304d\u307e\u3059\u3002\u8a3a\u65ad\u7528\u306b\u306f\u4f7f\u7528\u3044\u305f\u3060\u3051\u307e\u305b\u3093\u3002<\/p>\n","protected":false},"excerpt":{"rendered":"<p>\u306f\u3058\u3081\u306b \u7d44\u307f\u63db\u3048\u30bf\u30f3\u30d1\u30af\u8cea\u767a\u73fe\u306f\u3001\u591a\u304f\u306e\u7814\u7a76\u30d7\u30ed\u30b8\u30a7\u30af\u30c8\u306b\u304a\u3044\u3066\u6b20\u304b\u305b\u306a\u3044\u6280\u8853\u306e\u4e00\u3064\u3067\u3059\u3002\u54fa\u4e73\u985e\u7d30\u80de\u3001\u6606\u866b\u7d30\u80de\u3001\u9175\u6bcd\u3001\u5927\u8178\u83cc\u3092\u7528\u3044\u305f\u7cfb\u3001\u304a\u3088\u3073\u7121\u7d30\u80de\u767a\u73fe\u7cfb\u306a\u3069\u3055\u307e\u3056\u307e\u306a\u767a\u73fe\u7cfb\u304c\u958b\u767a\u3055\u308c\u3066\u3044\u307e\u3059\u304c\u3001\u3059\u3079\u3066\u306e\u30bf\u30f3\u30d1\u30af\u8cea\u3001\u30a2<\/p>\n","protected":false},"author":975,"featured_media":10014,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_monsterinsights_skip_tracking":false,"_genesis_hide_title":false,"_genesis_hide_breadcrumbs":false,"_genesis_hide_singular_image":false,"_genesis_hide_footer_widgets":false,"_genesis_custom_body_class":"","_genesis_custom_post_class":"","_genesis_layout":"","_jetpack_newsletter_access":"","_jetpack_dont_email_post_to_subs":false,"_jetpack_newsletter_tier_id":0,"_jetpack_memberships_contains_paywalled_content":false,"_jetpack_hide_featured_image":false,"_jetpack_featured_image_duplicate_dismissed":0,"_jetpack_feature_clip_id":0,"_jetpack_memberships_contains_paid_content":false,"footnotes":"","jetpack_post_was_ever_published":false},"categories":[156],"tags":[168],"division":[],"class_list":["post-8443","post","type-post","status-publish","format-standard","has-post-thumbnail","category-mol-bio","tag-protein-expression","entry"],"_selected_authors":"","_selected_reviewers":"","acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v28.9 (Yoast SEO v28.9) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>\u3042\u306a\u305f\u306e\u30bf\u30f3\u30d1\u30af\u8cea\u306b\u3068\u3063\u3066\u6700\u9069\u306a\u767a\u73fe\u7cfb\u306f\uff1f - Learning at the Bench<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/protein_expression_mb_bid_ts_1\/\" \/>\n<meta property=\"og:locale\" content=\"ja_JP\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"\u3042\u306a\u305f\u306e\u30bf\u30f3\u30d1\u30af\u8cea\u306b\u3068\u3063\u3066\u6700\u9069\u306a\u767a\u73fe\u7cfb\u306f\uff1f\" \/>\n<meta property=\"og:description\" content=\"\u306f\u3058\u3081\u306b \u7d44\u307f\u63db\u3048\u30bf\u30f3\u30d1\u30af\u8cea\u767a\u73fe\u306f\u3001\u591a\u304f\u306e\u7814\u7a76\u30d7\u30ed\u30b8\u30a7\u30af\u30c8\u306b\u304a\u3044\u3066\u6b20\u304b\u305b\u306a\u3044\u6280\u8853\u306e\u4e00\u3064\u3067\u3059\u3002\u54fa\u4e73\u985e\u7d30\u80de\u3001\u6606\u866b\u7d30\u80de\u3001\u9175\u6bcd\u3001\u5927\u8178\u83cc\u3092\u7528\u3044\u305f\u7cfb\u3001\u304a\u3088\u3073\u7121\u7d30\u80de\u767a\u73fe\u7cfb\u306a\u3069\u3055\u307e\u3056\u307e\u306a\u767a\u73fe\u7cfb\u304c\u958b\u767a\u3055\u308c\u3066\u3044\u307e\u3059\u304c\u3001\u3059\u3079\u3066\u306e\u30bf\u30f3\u30d1\u30af\u8cea\u3001\u30a2\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/protein_expression_mb_bid_ts_1\/\" \/>\n<meta property=\"og:site_name\" content=\"Learning at the Bench\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/ThermoFisherJapan\" \/>\n<meta property=\"article:published_time\" content=\"2021-01-29T02:25:39+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2024-07-04T04:13:02+00:00\" \/>\n<meta property=\"og:image\" content=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2021\/01\/shutterstock_1354969193.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"1024\" \/>\n\t<meta property=\"og:image:height\" content=\"768\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"LatB Staff\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:creator\" content=\"@ThermoFisherJP\" \/>\n<meta name=\"twitter:site\" content=\"@ThermoFisherJP\" \/>\n<meta name=\"twitter:label1\" content=\"\u57f7\u7b46\u8005\" \/>\n\t<meta name=\"twitter:data1\" content=\"LatB Staff\" \/>\n\t<meta name=\"twitter:label2\" content=\"\u63a8\u5b9a\u8aad\u307f\u53d6\u308a\u6642\u9593\" \/>\n\t<meta name=\"twitter:data2\" content=\"11\u5206\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/protein_expression_mb_bid_ts_1\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/protein_expression_mb_bid_ts_1\\\/\"},\"author\":{\"name\":\"LatB Staff\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#\\\/schema\\\/person\\\/8fb77bfc3606f049738f28976032baa7\"},\"headline\":\"\u3042\u306a\u305f\u306e\u30bf\u30f3\u30d1\u30af\u8cea\u306b\u3068\u3063\u3066\u6700\u9069\u306a\u767a\u73fe\u7cfb\u306f\uff1f\",\"datePublished\":\"2021-01-29T02:25:39+00:00\",\"dateModified\":\"2024-07-04T04:13:02+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/protein_expression_mb_bid_ts_1\\\/\"},\"wordCount\":96,\"commentCount\":0,\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/protein_expression_mb_bid_ts_1\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2021\\\/01\\\/shutterstock_1354969193.jpg\",\"keywords\":[\"\u30bf\u30f3\u30d1\u30af\u8cea\u767a\u73fe\"],\"articleSection\":[\"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023\"],\"inLanguage\":\"ja\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/protein_expression_mb_bid_ts_1\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/protein_expression_mb_bid_ts_1\\\/\",\"url\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/protein_expression_mb_bid_ts_1\\\/\",\"name\":\"\u3042\u306a\u305f\u306e\u30bf\u30f3\u30d1\u30af\u8cea\u306b\u3068\u3063\u3066\u6700\u9069\u306a\u767a\u73fe\u7cfb\u306f\uff1f - Learning at the Bench\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/protein_expression_mb_bid_ts_1\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/protein_expression_mb_bid_ts_1\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2021\\\/01\\\/shutterstock_1354969193.jpg\",\"datePublished\":\"2021-01-29T02:25:39+00:00\",\"dateModified\":\"2024-07-04T04:13:02+00:00\",\"author\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#\\\/schema\\\/person\\\/8fb77bfc3606f049738f28976032baa7\"},\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/protein_expression_mb_bid_ts_1\\\/#breadcrumb\"},\"inLanguage\":\"ja\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/protein_expression_mb_bid_ts_1\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"ja\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/protein_expression_mb_bid_ts_1\\\/#primaryimage\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2021\\\/01\\\/shutterstock_1354969193.jpg\",\"contentUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2021\\\/01\\\/shutterstock_1354969193.jpg\",\"width\":1024,\"height\":768},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/protein_expression_mb_bid_ts_1\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"\u3042\u306a\u305f\u306e\u30bf\u30f3\u30d1\u30af\u8cea\u306b\u3068\u3063\u3066\u6700\u9069\u306a\u767a\u73fe\u7cfb\u306f\uff1f\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#website\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/\",\"name\":\"Learning at the Bench\",\"description\":\"\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"ja\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#\\\/schema\\\/person\\\/8fb77bfc3606f049738f28976032baa7\",\"name\":\"LatB Staff\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"ja\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g\",\"caption\":\"LatB Staff\"},\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/author\\\/lgbadmin\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"\u3042\u306a\u305f\u306e\u30bf\u30f3\u30d1\u30af\u8cea\u306b\u3068\u3063\u3066\u6700\u9069\u306a\u767a\u73fe\u7cfb\u306f\uff1f - Learning at the Bench","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/protein_expression_mb_bid_ts_1\/","og_locale":"ja_JP","og_type":"article","og_title":"\u3042\u306a\u305f\u306e\u30bf\u30f3\u30d1\u30af\u8cea\u306b\u3068\u3063\u3066\u6700\u9069\u306a\u767a\u73fe\u7cfb\u306f\uff1f","og_description":"\u306f\u3058\u3081\u306b \u7d44\u307f\u63db\u3048\u30bf\u30f3\u30d1\u30af\u8cea\u767a\u73fe\u306f\u3001\u591a\u304f\u306e\u7814\u7a76\u30d7\u30ed\u30b8\u30a7\u30af\u30c8\u306b\u304a\u3044\u3066\u6b20\u304b\u305b\u306a\u3044\u6280\u8853\u306e\u4e00\u3064\u3067\u3059\u3002\u54fa\u4e73\u985e\u7d30\u80de\u3001\u6606\u866b\u7d30\u80de\u3001\u9175\u6bcd\u3001\u5927\u8178\u83cc\u3092\u7528\u3044\u305f\u7cfb\u3001\u304a\u3088\u3073\u7121\u7d30\u80de\u767a\u73fe\u7cfb\u306a\u3069\u3055\u307e\u3056\u307e\u306a\u767a\u73fe\u7cfb\u304c\u958b\u767a\u3055\u308c\u3066\u3044\u307e\u3059\u304c\u3001\u3059\u3079\u3066\u306e\u30bf\u30f3\u30d1\u30af\u8cea\u3001\u30a2","og_url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/protein_expression_mb_bid_ts_1\/","og_site_name":"Learning at the Bench","article_publisher":"https:\/\/www.facebook.com\/ThermoFisherJapan","article_published_time":"2021-01-29T02:25:39+00:00","article_modified_time":"2024-07-04T04:13:02+00:00","og_image":[{"width":1024,"height":768,"url":"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2021\/01\/shutterstock_1354969193.jpg","type":"image\/jpeg"}],"author":"LatB Staff","twitter_card":"summary_large_image","twitter_creator":"@ThermoFisherJP","twitter_site":"@ThermoFisherJP","twitter_misc":{"\u57f7\u7b46\u8005":"LatB Staff","\u63a8\u5b9a\u8aad\u307f\u53d6\u308a\u6642\u9593":"11\u5206"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/protein_expression_mb_bid_ts_1\/#article","isPartOf":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/protein_expression_mb_bid_ts_1\/"},"author":{"name":"LatB Staff","@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#\/schema\/person\/8fb77bfc3606f049738f28976032baa7"},"headline":"\u3042\u306a\u305f\u306e\u30bf\u30f3\u30d1\u30af\u8cea\u306b\u3068\u3063\u3066\u6700\u9069\u306a\u767a\u73fe\u7cfb\u306f\uff1f","datePublished":"2021-01-29T02:25:39+00:00","dateModified":"2024-07-04T04:13:02+00:00","mainEntityOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/protein_expression_mb_bid_ts_1\/"},"wordCount":96,"commentCount":0,"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/protein_expression_mb_bid_ts_1\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2021\/01\/shutterstock_1354969193.jpg","keywords":["\u30bf\u30f3\u30d1\u30af\u8cea\u767a\u73fe"],"articleSection":["\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023"],"inLanguage":"ja","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/protein_expression_mb_bid_ts_1\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/protein_expression_mb_bid_ts_1\/","url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/protein_expression_mb_bid_ts_1\/","name":"\u3042\u306a\u305f\u306e\u30bf\u30f3\u30d1\u30af\u8cea\u306b\u3068\u3063\u3066\u6700\u9069\u306a\u767a\u73fe\u7cfb\u306f\uff1f - Learning at the Bench","isPartOf":{"@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/protein_expression_mb_bid_ts_1\/#primaryimage"},"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/protein_expression_mb_bid_ts_1\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2021\/01\/shutterstock_1354969193.jpg","datePublished":"2021-01-29T02:25:39+00:00","dateModified":"2024-07-04T04:13:02+00:00","author":{"@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#\/schema\/person\/8fb77bfc3606f049738f28976032baa7"},"breadcrumb":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/protein_expression_mb_bid_ts_1\/#breadcrumb"},"inLanguage":"ja","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/protein_expression_mb_bid_ts_1\/"]}]},{"@type":"ImageObject","inLanguage":"ja","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/protein_expression_mb_bid_ts_1\/#primaryimage","url":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2021\/01\/shutterstock_1354969193.jpg","contentUrl":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2021\/01\/shutterstock_1354969193.jpg","width":1024,"height":768},{"@type":"BreadcrumbList","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/protein_expression_mb_bid_ts_1\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/"},{"@type":"ListItem","position":2,"name":"\u3042\u306a\u305f\u306e\u30bf\u30f3\u30d1\u30af\u8cea\u306b\u3068\u3063\u3066\u6700\u9069\u306a\u767a\u73fe\u7cfb\u306f\uff1f"}]},{"@type":"WebSite","@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#website","url":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/","name":"Learning at the Bench","description":"","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"ja"},{"@type":"Person","@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#\/schema\/person\/8fb77bfc3606f049738f28976032baa7","name":"LatB Staff","image":{"@type":"ImageObject","inLanguage":"ja","@id":"https:\/\/secure.gravatar.com\/avatar\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g","caption":"LatB Staff"},"url":"https:\/\/admin.acceleratingscience.com\/author\/lgbadmin\/"}]}},"taxonomy_info":{"category":[{"value":156,"label":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023"}],"post_tag":[{"value":168,"label":"\u30bf\u30f3\u30d1\u30af\u8cea\u767a\u73fe"}]},"featured_image_src_large":["https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2021\/01\/shutterstock_1354969193.jpg",760,570,false],"author_info":{"display_name":"LatB Staff","author_link":"https:\/\/admin.acceleratingscience.com\/author\/lgbadmin\/"},"comment_info":0,"category_info":[{"term_id":156,"name":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","slug":"mol-bio","term_group":0,"term_taxonomy_id":156,"taxonomy":"category","description":"","parent":0,"count":540,"filter":"raw","meta":[],"cat_ID":156,"category_count":540,"category_description":"","cat_name":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","category_nicename":"mol-bio","category_parent":0}],"tag_info":[{"term_id":168,"name":"\u30bf\u30f3\u30d1\u30af\u8cea\u767a\u73fe","slug":"protein-expression","term_group":0,"term_taxonomy_id":168,"taxonomy":"post_tag","description":"","parent":0,"count":10,"filter":"raw","meta":[]}],"jetpack-related-posts":[{"id":23864,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/protein-expression-cloning-bid-ts-mbr-25070\/","url_meta":{"origin":8443,"position":0},"title":"\u521d\u5fc3\u8005\u3067\u3082\u5b89\u5fc3\uff01\u7c21\u5358\u306b\u3067\u304d\u308b\u767a\u73fe\u30d9\u30af\u30bf\u30fc\u306e\u4f5c\u308a\u65b9\uff1a\u4eba\u5de5\u907a\u4f1d\u5b50\u5408\u6210\u30b5\u30fc\u30d3\u30b9\u306e\u5229\u7528\u6cd5","author":"LatB Staff","date":"2025\u5e7411\u670813\u65e5","format":false,"excerpt":"\u30bf\u30f3\u30d1\u30af\u8cea\u767a\u73fe\u5b9f\u9a13\u306b\u306f\u767a\u73fe\u30d9\u30af\u30bf\u30fc\u304c\u6b20\u304b\u305b\u307e\u305b\u3093\u304c\u3001\u4e00\u304b\u3089\u4f5c\u308b\u3068\u306a\u308b\u3068\u3001\u304b\u306a\u308a\u306e\u624b\u9593\u3068\u7d4c\u9a13\u304c\u5fc5\u8981\u3067\u3059\u2026","rel":"","context":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","block_context":{"text":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/mol-bio\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/10\/protein-expression-cloning-bid-ts-mbr-25070_eyecatch.png?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/10\/protein-expression-cloning-bid-ts-mbr-25070_eyecatch.png?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/10\/protein-expression-cloning-bid-ts-mbr-25070_eyecatch.png?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/10\/protein-expression-cloning-bid-ts-mbr-25070_eyecatch.png?resize=700%2C400&ssl=1 2x"},"classes":[]},{"id":24606,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/transfection-antibody-bid-ts-mbr-26004\/","url_meta":{"origin":8443,"position":1},"title":"\u7d30\u80de\u5185\u30bf\u30f3\u30d1\u30af\u8cea\u9664\u53bb\u30b7\u30b9\u30c6\u30e0\uff08Trim-Away\u6cd5\uff09\u306e\u7d39\u4ecb\uff5e\u30a8\u30ec\u30af\u30c8\u30ed\u30dd\u30ec\u30fc\u30b7\u30e7\u30f3\u6a5f\u5668\u3092\u4f7f\u7528\u3057\u3066\uff5e","author":"LatB Staff","date":"2026\u5e742\u67084\u65e5","format":false,"excerpt":"2018\u5e74\u306e\u6587\u732e(1)\u3067\u7d30\u80de\u5185\u306e\u5185\u5728\u6027\u30bf\u30f3\u30d1\u30af\u8cea\u3092\u76f4\u63a5\u5206\u89e3\u3059\u308b\u3001Trim-Away\u6cd5\u304c\u7d39\u4ecb\u3055\u308c\u307e\u3057\u305f\u2026","rel":"","context":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","block_context":{"text":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/mol-bio\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/01\/transfection-antibody-bid-ts-mbr-26004_eyecatch.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/01\/transfection-antibody-bid-ts-mbr-26004_eyecatch.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/01\/transfection-antibody-bid-ts-mbr-26004_eyecatch.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/01\/transfection-antibody-bid-ts-mbr-26004_eyecatch.jpg?resize=700%2C400&ssl=1 2x"},"classes":[]},{"id":25565,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/exosome-antibody-ts-r-25068\/","url_meta":{"origin":8443,"position":2},"title":"\u3010\u7b2c8\u56de\u3011\u30a8\u30af\u30bd\u30bd\u30fc\u30e0\u30b5\u30d6\u30bf\u30a4\u30d7\u306e\u5206\u753b\u6cd5 \uff1a \u30a6\u30a7\u30b9\u30bf\u30f3\u30d6\u30ed\u30c3\u30c8\uff0fqRT-PCR\uff0f\u30b7\u30fc\u30b1\u30f3\u30b9\u89e3\u6790\u306b\u9069\u3057\u305f\u5206\u753b\u65b9\u6cd5","author":"LatB Staff","date":"2026\u5e749\u670829\u65e5","format":false,"excerpt":"\u672c\u7a3f\u3067\u306f\u3001\u30a8\u30af\u30bd\u30bd\u30fc\u30e0\u819c\u4e0a\u306e\u7279\u5b9a\u306e\u30bf\u30f3\u30d1\u30af\u8cea\u3092\u6a19\u7684\u3068\u3057\u305f\u514d\u75ab\u5438\u7740\u6cd5\u306b\u57fa\u3065\u304f\u5206\u753b\u624b\u6cd5\u3092\u7d39\u4ecb\u3057\u307e\u3059\u3002\u30a8\u30af\u2026","rel":"","context":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","block_context":{"text":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/mol-bio\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25019_eyecatch.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25019_eyecatch.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25019_eyecatch.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25019_eyecatch.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25019_eyecatch.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25019_eyecatch.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":24108,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/cell-culture-cell-count-bid-ts-mbr-25065-2\/","url_meta":{"origin":8443,"position":3},"title":"\u3010\u7b2c6\u56de\u3011 \u30a6\u30a7\u30b9\u30bf\u30f3\u30d6\u30ed\u30c3\u30c6\u30a3\u30f3\u30b0\u6cd5\u306b\u3088\u308b \u300e\u30a8\u30af\u30bd\u30bd\u30fc\u30e0\u4e2d\u306e\u30bf\u30f3\u30d1\u30af\u8cea\uff08Protein cargo\uff09\u300f\u306e\u89e3\u6790","author":"LatB Staff","date":"2026\u5e747\u670815\u65e5","format":false,"excerpt":"\u30a8\u30af\u30bd\u30bd\u30fc\u30e0\uff08\u30a8\u30ad\u30bd\u30bd\u30fc\u30e0\uff09\u306f\u3001\u7d30\u80de\u304b\u3089\u5206\u6ccc\u3055\u308c\u308b\u5c0f\u3055\u306a\u819c\u5c0f\u80de\u3067\u3001\u6838\u9178\uff08RNA\uff0fDNA\uff09\u3060\u3051\u3067\u306a\u304f\u3001\u2026","rel":"","context":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","block_context":{"text":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/mol-bio\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/11\/cell-culture-cell-count-bid-ts-mbr-25065_eyecatch.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/11\/cell-culture-cell-count-bid-ts-mbr-25065_eyecatch.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/11\/cell-culture-cell-count-bid-ts-mbr-25065_eyecatch.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/11\/cell-culture-cell-count-bid-ts-mbr-25065_eyecatch.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/11\/cell-culture-cell-count-bid-ts-mbr-25065_eyecatch.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/11\/cell-culture-cell-count-bid-ts-mbr-25065_eyecatch.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":25540,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/cloning-cell-separation-bid-ts-mbr-26023\/","url_meta":{"origin":8443,"position":4},"title":"\u5927\u8178\u83cc\u306e\u98fc\u3044\u65b92\uff5e\u5b9f\u969b\u306b\u57f9\u990a\u3057\u3066\u307f\u3088\u3046","author":"LatB Staff","date":"2026\u5e748\u670826\u65e5","format":false,"excerpt":"\u30d6\u30ed\u30b0\u300c\u5927\u8178\u83cc\u306e\u98fc\u3044\u65b9\uff5e\u5b9f\u9a13\u306b\u5fc5\u8981\u306a\u8a2d\u5099\u3092\u305d\u308d\u3048\u3088\u3046\u300d\u3067\u306f\u3001\u30af\u30ed\u30fc\u30cb\u30f3\u30b0\u3084\u7d44\u307f\u63db\u3048\u30bf\u30f3\u30d1\u30af\u8cea\u767a\u73fe\u306e\u7528\u2026","rel":"","context":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","block_context":{"text":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/mol-bio\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/08\/cloning-cell-separation-bid-ts-mbr-26023_eyecatch.png?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/08\/cloning-cell-separation-bid-ts-mbr-26023_eyecatch.png?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/08\/cloning-cell-separation-bid-ts-mbr-26023_eyecatch.png?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/08\/cloning-cell-separation-bid-ts-mbr-26023_eyecatch.png?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/08\/cloning-cell-separation-bid-ts-mbr-26023_eyecatch.png?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/08\/cloning-cell-separation-bid-ts-mbr-26023_eyecatch.png?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":24187,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/ngs-gene-expression-csd-ts-ion-25073\/","url_meta":{"origin":8443,"position":5},"title":"\u3010\u3084\u3063\u3066\u307f\u305f\u3011\u5fae\u91cf\u30fb\u5206\u89e3RNA\u306b\u3088\u308b\u767a\u73fe\u89e3\u6790\u306e\u6700\u9069\u89e3\u306f\uff1fRNA-Seq\u3068Ion AmpliSeq Transcriptome\u3092\u6bd4\u3079\u3066\u307f\u305f","author":"LatB Staff","date":"2025\u5e7411\u670828\u65e5","format":false,"excerpt":"\u6b21\u4e16\u4ee3\u30b7\u30fc\u30b1\u30f3\u30b5\u3067\u306e\u767a\u73fe\u89e3\u6790\u306b\u53d6\u308a\u7d44\u3080\u969b\u3001RNA\u30b5\u30f3\u30d7\u30eb\u304c\u300c\u5c11\u306a\u3059\u304e\u308b\u300d\u300c\u5206\u89e3\u3057\u3066\u3044\u308b\u300d\u3068\u3044\u3046\u72b6\u6cc1\u306f\u2026","rel":"","context":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","block_context":{"text":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/mol-bio\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/11\/ngs-gene-expression-csd-ts-ion-25073_eyecatch-scaled.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/11\/ngs-gene-expression-csd-ts-ion-25073_eyecatch-scaled.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/11\/ngs-gene-expression-csd-ts-ion-25073_eyecatch-scaled.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/11\/ngs-gene-expression-csd-ts-ion-25073_eyecatch-scaled.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/11\/ngs-gene-expression-csd-ts-ion-25073_eyecatch-scaled.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/11\/ngs-gene-expression-csd-ts-ion-25073_eyecatch-scaled.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]}],"jetpack_sharing_enabled":true,"amp_enabled":true,"jetpack_featured_media_url":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2021\/01\/shutterstock_1354969193.jpg","_links":{"self":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/posts\/8443","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/users\/975"}],"replies":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/comments?post=8443"}],"version-history":[{"count":0,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/posts\/8443\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/media\/10014"}],"wp:attachment":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/media?parent=8443"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/categories?post=8443"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/tags?post=8443"},{"taxonomy":"division","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/division?post=8443"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}