{"id":847,"date":"2018-04-26T00:00:00","date_gmt":"2018-04-26T00:00:00","guid":{"rendered":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/transfectiontips-1\/"},"modified":"2024-12-25T16:22:16","modified_gmt":"2024-12-25T07:22:16","slug":"transfectiontips-1","status":"publish","type":"post","link":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/transfectiontips-1\/","title":{"rendered":"\u57f9\u990a\u7d30\u80de\u306b\u304a\u3051\u308bsiRNA\u306e\u5c0e\u5165\u3092\u6700\u9069\u5316\u3059\u308bTips\u30c8\u30c3\u30d710\u3010\u524d\u7de8\u3011"},"content":{"rendered":"<p>\u307f\u306a\u3055\u3093\u306f<a href=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/guidelines-for-maintaining-cultured-cells\/?cid=bid_clb_tfx_r04_jp_cp0000_pjt0000_bid00000_0so_blg_op_awa_oc_s00_cc18_Social_LAB\" target=\"_blank\" rel=\"noopener\">\u57f9\u990a\u7d30\u80de<\/a>\u3092\u6271\u3046\u4e2d\u3067\u3001\u30c8\u30e9\u30f3\u30b9\u30d5\u30a7\u30af\u30b7\u30e7\u30f3\u306b\u304a\u56f0\u308a\u3067\u306f\u306a\u3044\u3067\u3057\u3087\u3046\u304b\uff1f<\/p>\n<p>\u672c\u8a18\u4e8b\u3067\u306f\u3001\u591a\u304f\u306e\u4eba\u304c\u5229\u7528\u3059\u308b\u30c8\u30e9\u30f3\u30b9\u30d5\u30a7\u30af\u30b7\u30e7\u30f3\u306e\u6700\u9069\u5316\u306b\u5f79\u7acb\u3064\u8981\u7d2010\u70b9\uff08\u4eca\u56de\u306f1~5\u306e\u4e0b\u8a185\u70b9\uff09\u306b\u3064\u3044\u3066\u7d39\u4ecb\u3044\u305f\u3057\u307e\u3059\u3002<\/p>\n<p>&nbsp;<\/p>\n<p>\u4ee5\u4e0b\u306e\u63a8\u5968\u4e8b\u9805\u306f\u3059\u3079\u3066siRNA\u306b\u95a2\u3059\u308b\u3082\u306e\u3067\u3059\u304c\u3001miRNAmimic\/inhibitor\u306b\u3082\u9069\u7528\u53ef\u80fd\u3067\u3059\u3002<\/p>\n<p>&nbsp;<\/p>\n<h1>\uff11. \u5b9f\u9a13\u3092\u884c\u3046\u969b\u306e\u4e00\u8cab\u6027<\/h1>\n<p>\u6761\u4ef6\u3092\u6700\u9069\u5316\u3059\u308b\u969b\u3001\u30d7\u30ed\u30c8\u30b3\u30eb\u306e\u5404\u30b9\u30c6\u30c3\u30d7\u3092\u5b9f\u65bd\u3059\u308b\u9806\u5e8f\u3001\u30bf\u30a4\u30df\u30f3\u30b0\u304a\u3088\u3073\u65b9\u6cd5\u306b\u4e00\u8cab\u6027\u304c\u3042\u308b\u3088\u3046\u306b\u6ce8\u610f\u3057\u307e\u3057\u3087\u3046\u3002\u5b9f\u9a13\u5168\u4f53\u3092\u901a\u3058\u3066\u30d7\u30ed\u30bb\u30b9\u306e\u5909\u52d5\u304c\u5c11\u306a\u304f\u3059\u308b\u3053\u3068\u3067\u3001\u7d50\u679c\u306e\u518d\u73fe\u6027\u3068\u4fe1\u983c\u6027\u304c\u3088\u308a\u9ad8\u304f\u306a\u308b\u304b\u3089\u3067\u3059\u3002<\/p>\n<h1>\uff12. \u30c8\u30e9\u30f3\u30b9\u30d5\u30a7\u30af\u30b7\u30e7\u30f3\u30d7\u30ed\u30c8\u30b3\u30eb\u306e\u9069\u5207\u306a\u9078\u629e<\/h1>\n<ul>\n<li>\u6a19\u6e96\u7684\u306a\u30c8\u30e9\u30f3\u30b9\u30d5\u30a7\u30af\u30b7\u30e7\u30f3\u30d7\u30ed\u30c8\u30b3\u30eb\uff08<strong>\u30d5\u30a9\u30ef\u30fc\u30c9\u30c8\u30e9\u30f3\u30b9\u30d5\u30a7\u30af\u30b7\u30e7\u30f3<\/strong>\uff09\n<ul>\n<li>\u30c8\u30e9\u30f3\u30b9\u30d5\u30a7\u30af\u30b7\u30e7\u30f3\u306e\u7d0424\u6642\u9593\u524d\u306b\u7d30\u80de\u3092\u64ad\u7a2e\u3057\u307e\u3059\u3002<\/li>\n<\/ul>\n<\/li>\n<\/ul>\n<ul>\n<li><strong>\u30ea\u30d0\u30fc\u30b9\u30c8\u30e9\u30f3\u30b9\u30d5\u30a7\u30af\u30b7\u30e7\u30f3<\/strong>\n<ul>\n<li>\u7d30\u80de\u3092\u64ad\u7a2e\u3059\u308b\u540c\u3058\u6642\u671f\u306b\u30c8\u30e9\u30f3\u30b9\u30d5\u30a7\u30af\u30b7\u30e7\u30f3\u3092\u884c\u3046\u3053\u3068\u304c\u53ef\u80fd\u3067\u3001<strong>\u524d\u65e5\u306e\u7d30\u80de\u64ad\u7a2e\u64cd\u4f5c\u3092\u7701\u304f\u3053\u3068\u304c\u3067\u304d\u307e\u3059\u3002<\/strong>\u3055\u3089\u306b\u3001\u9069\u5207\u306a\u30ea\u30d0\u30fc\u30b9\u30c8\u30e9\u30f3\u30b9\u30d5\u30a7\u30af\u30b7\u30e7\u30f3\u30d7\u30ed\u30c8\u30b3\u30eb\uff08<a href=\"http:\/\/www.thermofisher.com\/order\/catalog\/en\/US\/adirect\/lt?cmd=catProductDetail&amp;productID=AM4510?cid=bid_clb_tfx_r04_jp_cp0000_pjt0000_bid00000_0so_blg_op_awa_oc_s00_cc18_Social_LAB\" target=\"_blank\" rel=\"noopener\">RNAiMax<\/a>\u306e\u4f7f\u7528\u306a\u3069\uff09\u3092\u7528\u3044\u305f\u7d50\u679c\u3001<strong>\u3042\u308b\u7d30\u80de\u682a\u3067\u306f\u3088\u308a\u52b9\u7387\u306e\u3088\u3044\u30c8\u30e9\u30f3\u30b9\u30d5\u30a7\u30af\u30c8\u304c\u53ef\u80fd<\/strong>\u306b\u306a\u308a\u3001siRNA\u6fc3\u5ea6\u306e\u4f4e\u6e1b\uff08\u30aa\u30d5\u30bf\u30fc\u30b2\u30c3\u30c8\u52b9\u679c\u3092\u6e1b\u5c11\u3055\u305b\u308b\u5834\u5408\u304c\u3042\u308b\uff09\u3084\u3001\u3088\u308a\u5e83\u7bc4\u56f2\u306e\u7d30\u80de\u6fc3\u5ea6\u3067\u5229\u7528\u53ef\u80fd\u3068\u306a\u308b\u3053\u3068\u3082\u5206\u304b\u3063\u3066\u3044\u307e\u3059\u3002<\/li>\n<\/ul>\n<\/li>\n<\/ul>\n<p>&nbsp;<\/p>\n<h1>\uff13. \u5065\u5eb7\u306a\u7d30\u80de\u3092\u6700\u9069\u306a\u5bc6\u5ea6\u3067\u64ad\u7a2e<\/h1>\n<p>\u7d30\u80de\u306f\u300140\uff5e80\uff05\u306e\u30b3\u30f3\u30d5\u30eb\u30a8\u30f3\u30c8\uff08\u7d30\u80de\u5bc6\u5ea6\uff09\u3067\u3001\u6bd4\u8f03\u7684\u5c11\u306a\u3044\u7d99\u4ee3\u6570\uff0850\u56de\u672a\u6e80\u306a\u3069\uff09\u3067\u53e4\u3059\u304e\u306a\u3044\u3082\u306e\u3092\u4f7f\u7528\u3059\u308b\u5fc5\u8981\u304c\u3042\u308a\u307e\u3059\u3002\u3053\u308c\u306f\u3001<strong>\u6642\u9593\u304c\u7d4c\u3064\u306b\u3064\u308c\u3066\u57f9\u990a\u7d30\u80de\u306f\u3001\u65e9\u671f\u7d99\u4ee3\u6642\u306e\u7d30\u80de\u3068\u6bd4\u3079\u3066\u8868\u73fe\u578b\u30fb\u6210\u9577\u7279\u6027\u306a\u3069\u306e\u767a\u73fe\u30d7\u30ed\u30d5\u30a1\u30a4\u30eb\u304c\u3088\u308a\u4e0d\u5747\u4e00\u306b\u306a\u3063\u3066\u304f\u308b\u304b\u3089<\/strong>\u3067\u3059\u3002<\/p>\n<p>\u307e\u305f\u3001\u591a\u304f\u306e\u7d30\u80de\u306f\u3001\u57f9\u990a\u6761\u4ef6\u306b\u3088\u3063\u3066\u30b9\u30c8\u30ec\u30b9\u304c\u304b\u3051\u3089\u308c\u305f\u5834\u5408\u3067\u3082\u3053\u3046\u3057\u305f\u767a\u73fe\u30d7\u30ed\u30d5\u30a1\u30a4\u30eb\u306e\u5909\u5316\u304c\u767a\u751f\u3057\u3066\u3057\u307e\u3044\u307e\u3059\uff08\u4e0b\u8a18\u53c2\u7167\uff09\u3002<\/p>\n<p>\u767a\u73fe\u30d7\u30ed\u30d5\u30a1\u30a4\u30eb\u306e\u5909\u5316\u306b\u5f71\u97ff\u3057\u5f97\u308b<strong>6\u3064<\/strong>\u306e\u8981\u56e0<\/p>\n<ul>\n<li>\u983b\u7e41\u306a\u6e29\u5ea6\u30fbpH\u306e\u5909\u5316<\/li>\n<li>\u7d30\u80de\u306e\u904e\u5270\u6210\u9577\u306b\u3088\u308b\u57f9\u5730\u4e2d\u306e\u6804\u990a\u4e0d\u8db3<\/li>\n<li>\u975e\u5e38\u306b\u4f4e\u3044\u7d30\u80de\u5bc6\u5ea6\u3067\u306e\u7d99\u4ee3\u57f9\u990a\u306b\u8d77\u56e0\u3059\u308b\u4e0d\u5b89\u5b9a\u6027<\/li>\n<li>\u30c8\u30ea\u30d7\u30b7\u30f3\u3078\u306e\u9577\u671f\u66dd\u9732<\/li>\n<li>\u6fc0\u3057\u3044\u30d4\u30da\u30c3\u30c8\u64cd\u4f5c\u3084\u9060\u5fc3\u5206\u96e2<\/li>\n<li>\u30de\u30a4\u30b3\u30d7\u30e9\u30ba\u30de\u6c5a\u67d3<\/li>\n<\/ul>\n<p>&nbsp;<\/p>\n<p>\u307e\u305f\u3001\u30c8\u30e9\u30f3\u30b9\u30d5\u30a7\u30af\u30b7\u30e7\u30f3\u3092\u884c\u3046\u969b\u306b\u306f\u3001\u7d30\u80de\u304c\u591a\u3059\u304e\u308b\u307e\u305f\u306f\u5c11\u306a\u3059\u304e\u308b\u7d30\u80de\u5bc6\u5ea6\u306f\u30c8\u30e9\u30f3\u30b9\u30d5\u30a7\u30af\u30b7\u30e7\u30f3\u52b9\u7387\u306b\u5f71\u97ff\u3092\u4e0e\u3048\u308b\u53ef\u80fd\u6027\u304c\u3042\u308b\u306e\u3067\u6ce8\u610f\u304c\u5fc5\u8981\u3067\u3059\u3002<\/p>\n<p>\u671b\u307e\u3057\u3044\u30c8\u30e9\u30f3\u30b9\u30d5\u30a7\u30af\u30b7\u30e7\u30f3\u5bb9\u5668\u306e\u8868\u9762\u7a4d\u306b\u57fa\u3065\u3044\u3066\u3001\u7d30\u80de\u5bc6\u5ea6\u306b\u3064\u3044\u3066\u6761\u4ef6\u691c\u8a0e\u3059\u308b\u3068\u3088\u3044\u3067\u3057\u3087\u3046\u3002<\/p>\n<p>&nbsp;<\/p>\n<h1>\uff14. \u9069\u5207\u306a\u57f9\u5730\u304a\u3088\u3073\u57f9\u990a\u6761\u4ef6\u306e\u9078\u629e<\/h1>\n<p>\u2714<strong>\u6297\u751f\u7269\u8cea<\/strong><\/p>\n<p>\u5fc5\u8981\u3067\u306a\u3044\u5834\u5408\u3084\u3001siRNA\u306e\u7d30\u80de\u3078\u306e\u53d6\u308a\u8fbc\u307f\u6642\u306b\u7d30\u80de\u6bd2\u6027\u3092\u5897\u52a0\u3055\u305b\u3066\u3057\u307e\u3046\u3053\u3068\u3082\u3042\u308a\u307e\u3059\u306e\u3067\u9664\u3044\u3066\u304f\u3060\u3055\u3044\u3002<\/p>\n<p>\u2714<strong>siRNA\u30c8\u30e9\u30f3\u30b9\u30d5\u30a7\u30af\u30b7\u30e7\u30f3\u8a66\u85ac<\/strong><\/p>\n<p>\u30c8\u30e9\u30f3\u30b9\u30d5\u30a7\u30af\u30b7\u30e7\u30f3\u306e\u6761\u4ef6\u3068\u3057\u3066\u3001\u7121\u8840\u6e05\u307e\u305f\u306f\u4f4e\u8840\u6e05\u57f9\u5730\u3092\u5fc5\u8981\u3068\u3059\u308b\u3053\u3068\u304c\u3042\u308b\u305f\u3081\u3001<strong>\u5fc5\u305a\u30e1\u30fc\u30ab\u30fc\u306e\u63a8\u5968\u4e8b\u9805\u306b\u6ce8\u610f\u3057\u3066\u304f\u3060\u3055\u3044<\/strong>\u3002<\/p>\n<p>\u2714<strong>\u57f9\u5730<\/strong><\/p>\n<p>\u76ee\u7684\u306e\u7d30\u80de\u306b\u9069\u3057\u305f\u57f9\u5730\u3092\u9078\u629e\u3057\u3066\u304f\u3060\u3055\u3044\u3002\u4f8b\u3048\u3070\u3001\u4ed6\u306e\u7d30\u80de\u3088\u308a\u3082\u591a\u304f\u306e\u30b0\u30eb\u30b3\u30fc\u30b9\u3092\u5fc5\u8981\u3068\u3059\u308b\u3082\u306e\u3084\u3001\u8ffd\u52a0\u306e\u30a2\u30df\u30ce\u9178\u3092\u5fc5\u8981\u3068\u3059\u308b\u7d30\u80de\u3082\u3042\u308a\u307e\u3059\u3002<\/p>\n<h1>\uff15. \u9ad8\u54c1\u8cea\u306asiRNA\u3092\u3088\u308a\u4f4e\u3044\u6709\u52b9\u6fc3\u5ea6\u3067\u306e\u4f7f\u7528<\/h1>\n<p>siRNA\u306f\u3001\u30a8\u30bf\u30ce\u30fc\u30eb\u3001\u5869\u985e\u306a\u3069\u306e\u5408\u6210\u904e\u7a0b\u3067<strong>\u30b3\u30f3\u30bf\u30df\u3059\u308b\u7269\u8cea\u3092\u542b\u307e\u306a\u3044\u3088\u3046\u306b\u3057\u306a\u3051\u308c\u3070\u306a\u308a\u307e\u305b\u3093\u3002<\/strong>\u307e\u305f\u300130 bp\u3088\u308a\u9577\u3044\u4e8c\u672c\u9396RNA\u306f\u3001\u975e\u7279\u7570\u7684\u306a\u30a4\u30f3\u30bf\u30fc\u30d5\u30a7\u30ed\u30f3\u5fdc\u7b54\u3092\u6d3b\u6027\u5316\u3059\u308b\u3053\u3068\u306b\u3088\u3063\u3066\u907a\u4f1d\u5b50\u767a\u73fe\u3092\u5909\u5316\u3055\u305b\u3001\u7d30\u80de\u6bd2\u6027\u3092\u3082\u305f\u3089\u3057\u307e\u3059\u3002<\/p>\n<p>&nbsp;<\/p>\n<p>\u3044\u304b\u304c\u3067\u3057\u305f\u3067\u3057\u3087\u3046\u304b\uff1f<\/p>\n<p>\u57f9\u990a\u7d30\u80de\u306b\u304a\u3051\u308bsiRNA\u306e\u5c0e\u5165\u3092\u6700\u9069\u5316\u3059\u308bTips \u30c8\u30c3\u30d710\u3010\u5f8c\u7de8\u3011\u306b\u3064\u3044\u3066\u3082\u3054\u53c2\u7167\u304f\u3060\u3055\u3044\uff01<\/p>\n<p>&nbsp;<\/p>\n<h1>\u3010\u7121\u6599\u30c0\u30a6\u30f3\u30ed\u30fc\u30c9\u3011\u7d30\u80de\u57f9\u990a\u57fa\u790e\u30cf\u30f3\u30c9\u30d6\u30c3\u30af<\/h1>\n<p>\u73fe\u5728\u3001\u4e0b\u8a182\u70b9\u306e\u57fa\u790e\u60c5\u5831\u3092\u307e\u3068\u3081\u305f\u7121\u6599\u30cf\u30f3\u30c9\u30d6\u30c3\u30af\u3092\u3054\u7528\u610f\u3057\u3066\u3044\u307e\u3059\uff08\u65e5\u672c\u8a9e\u7248\u3001\u7d04100\u30da\u30fc\u30b8\uff09\u3002<\/p>\n<ul>\n<li>\u7d30\u80de\u57f9\u990a<\/li>\n<li>\u30c8\u30e9\u30f3\u30b9\u30d5\u30a7\u30af\u30b7\u30e7\u30f3<\/li>\n<\/ul>\n<p>PDF\u30d5\u30a1\u30a4\u30eb\u306e\u30c0\u30a6\u30f3\u30ed\u30fc\u30c9\u3092\u3054\u5e0c\u671b\u306e\u65b9\u306f\u3001\u4e0b\u8a18\u30dc\u30bf\u30f3\u3088\u308a\u304a\u7533\u3057\u8fbc\u307f\u304f\u3060\u3055\u3044\uff01<\/p>\n<p><a class=\"btn btn-red\" href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/global\/forms\/gibco-cell-culture-basics-handbook-form.html?CID=bid_clb_tfx_r04_jp_cp0000_pjt0000_bid00000_0so_blg_op_awa_oc_s00_cc18_Social_LAB\" target=\"_blank\" rel=\"noopener\">\u7d30\u80de\u57f9\u990a\u57fa\u790e\u30cf\u30f3\u30c9\u30d6\u30c3\u30af\u3092\u30c0\u30a6\u30f3\u30ed\u30fc\u30c9<\/a><\/p>\n<p>&nbsp;<\/p>\n<p>\u7814\u7a76\u7528\u306b\u306e\u307f\u4f7f\u7528\u3067\u304d\u307e\u3059\u3002\u8a3a\u65ad\u7528\u306b\u306f\u4f7f\u7528\u3044\u305f\u3060\u3051\u307e\u305b\u3093\u3002<\/p>\n","protected":false},"excerpt":{"rendered":"<p>\u307f\u306a\u3055\u3093\u306f\u57f9\u990a\u7d30\u80de\u3092\u6271\u3046\u4e2d\u3067\u3001\u30c8\u30e9\u30f3\u30b9\u30d5\u30a7\u30af\u30b7\u30e7\u30f3\u306b\u304a\u56f0\u308a\u3067\u306f\u306a\u3044\u3067\u3057\u3087\u3046\u304b\uff1f \u672c\u8a18\u4e8b\u3067\u306f\u3001\u591a\u304f\u306e\u4eba\u304c\u5229\u7528\u3059\u308b\u30c8\u30e9\u30f3\u30b9\u30d5\u30a7\u30af\u30b7\u30e7\u30f3\u306e\u6700\u9069\u5316\u306b\u5f79\u7acb\u3064\u8981\u7d2010\u70b9\uff08\u4eca\u56de\u306f1~5\u306e\u4e0b\u8a185\u70b9\uff09\u306b\u3064\u3044\u3066\u7d39\u4ecb\u3044\u305f\u3057\u307e\u3059\u3002 &nbsp;<\/p>\n","protected":false},"author":988,"featured_media":3622,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_monsterinsights_skip_tracking":false,"_genesis_hide_title":false,"_genesis_hide_breadcrumbs":false,"_genesis_hide_singular_image":false,"_genesis_hide_footer_widgets":false,"_genesis_custom_body_class":"","_genesis_custom_post_class":"","_genesis_layout":"","_jetpack_newsletter_access":"","_jetpack_dont_email_post_to_subs":false,"_jetpack_newsletter_tier_id":0,"_jetpack_memberships_contains_paywalled_content":false,"_jetpack_feature_clip_id":0,"_jetpack_memberships_contains_paid_content":false,"footnotes":"","jetpack_post_was_ever_published":false},"categories":[159],"tags":[67],"division":[],"class_list":["post-847","post","type-post","status-publish","format-standard","has-post-thumbnail","category-cell","tag-transfection","entry"],"_selected_authors":"","_selected_reviewers":"","acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v27.8 (Yoast SEO v27.8) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>\u57f9\u990a\u7d30\u80de\u306b\u304a\u3051\u308bsiRNA\u306e\u5c0e\u5165\u3092\u6700\u9069\u5316\u3059\u308bTips\u30c8\u30c3\u30d710\u3010\u524d\u7de8\u3011 - Learning at the Bench<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/transfectiontips-1\/\" \/>\n<meta property=\"og:locale\" content=\"ja_JP\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"\u57f9\u990a\u7d30\u80de\u306b\u304a\u3051\u308bsiRNA\u306e\u5c0e\u5165\u3092\u6700\u9069\u5316\u3059\u308bTips\u30c8\u30c3\u30d710\u3010\u524d\u7de8\u3011\" \/>\n<meta property=\"og:description\" content=\"\u307f\u306a\u3055\u3093\u306f\u57f9\u990a\u7d30\u80de\u3092\u6271\u3046\u4e2d\u3067\u3001\u30c8\u30e9\u30f3\u30b9\u30d5\u30a7\u30af\u30b7\u30e7\u30f3\u306b\u304a\u56f0\u308a\u3067\u306f\u306a\u3044\u3067\u3057\u3087\u3046\u304b\uff1f \u672c\u8a18\u4e8b\u3067\u306f\u3001\u591a\u304f\u306e\u4eba\u304c\u5229\u7528\u3059\u308b\u30c8\u30e9\u30f3\u30b9\u30d5\u30a7\u30af\u30b7\u30e7\u30f3\u306e\u6700\u9069\u5316\u306b\u5f79\u7acb\u3064\u8981\u7d2010\u70b9\uff08\u4eca\u56de\u306f1~5\u306e\u4e0b\u8a185\u70b9\uff09\u306b\u3064\u3044\u3066\u7d39\u4ecb\u3044\u305f\u3057\u307e\u3059\u3002 &nbsp;\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/transfectiontips-1\/\" \/>\n<meta property=\"og:site_name\" content=\"Learning at the Bench\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/ThermoFisherJapan\" \/>\n<meta property=\"article:published_time\" content=\"2018-04-26T00:00:00+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2024-12-25T07:22:16+00:00\" \/>\n<meta property=\"og:image\" content=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/COL04097-iStock-15956581-XXXLARGE-1.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"1200\" \/>\n\t<meta property=\"og:image:height\" content=\"630\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"LATB Staff\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:creator\" content=\"@ThermoFisherJP\" \/>\n<meta name=\"twitter:site\" content=\"@ThermoFisherJP\" \/>\n<meta name=\"twitter:label1\" content=\"\u57f7\u7b46\u8005\" \/>\n\t<meta name=\"twitter:data1\" content=\"LATB Staff\" \/>\n\t<meta name=\"twitter:label2\" content=\"\u63a8\u5b9a\u8aad\u307f\u53d6\u308a\u6642\u9593\" \/>\n\t<meta name=\"twitter:data2\" content=\"5\u5206\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/transfectiontips-1\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/transfectiontips-1\\\/\"},\"author\":{\"name\":\"LATB Staff\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#\\\/schema\\\/person\\\/201e6a5abb838fa34e8ff0174b015d36\"},\"headline\":\"\u57f9\u990a\u7d30\u80de\u306b\u304a\u3051\u308bsiRNA\u306e\u5c0e\u5165\u3092\u6700\u9069\u5316\u3059\u308bTips\u30c8\u30c3\u30d710\u3010\u524d\u7de8\u3011\",\"datePublished\":\"2018-04-26T00:00:00+00:00\",\"dateModified\":\"2024-12-25T07:22:16+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/transfectiontips-1\\\/\"},\"wordCount\":25,\"commentCount\":0,\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/transfectiontips-1\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2019\\\/07\\\/COL04097-iStock-15956581-XXXLARGE-1.jpg\",\"keywords\":[\"\u30c8\u30e9\u30f3\u30b9\u30d5\u30a7\u30af\u30b7\u30e7\u30f3\"],\"articleSection\":[\"\u7d30\u80de\u57f9\u990a\u30fb\u30a4\u30e1\u30fc\u30b8\u30f3\u30b0\"],\"inLanguage\":\"ja\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/transfectiontips-1\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/transfectiontips-1\\\/\",\"url\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/transfectiontips-1\\\/\",\"name\":\"\u57f9\u990a\u7d30\u80de\u306b\u304a\u3051\u308bsiRNA\u306e\u5c0e\u5165\u3092\u6700\u9069\u5316\u3059\u308bTips\u30c8\u30c3\u30d710\u3010\u524d\u7de8\u3011 - Learning at the Bench\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/transfectiontips-1\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/transfectiontips-1\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2019\\\/07\\\/COL04097-iStock-15956581-XXXLARGE-1.jpg\",\"datePublished\":\"2018-04-26T00:00:00+00:00\",\"dateModified\":\"2024-12-25T07:22:16+00:00\",\"author\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#\\\/schema\\\/person\\\/201e6a5abb838fa34e8ff0174b015d36\"},\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/transfectiontips-1\\\/#breadcrumb\"},\"inLanguage\":\"ja\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/transfectiontips-1\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"ja\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/transfectiontips-1\\\/#primaryimage\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2019\\\/07\\\/COL04097-iStock-15956581-XXXLARGE-1.jpg\",\"contentUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2019\\\/07\\\/COL04097-iStock-15956581-XXXLARGE-1.jpg\",\"width\":1200,\"height\":630},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/transfectiontips-1\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"\u57f9\u990a\u7d30\u80de\u306b\u304a\u3051\u308bsiRNA\u306e\u5c0e\u5165\u3092\u6700\u9069\u5316\u3059\u308bTips\u30c8\u30c3\u30d710\u3010\u524d\u7de8\u3011\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#website\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/\",\"name\":\"Learning at the Bench\",\"description\":\"\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"ja\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#\\\/schema\\\/person\\\/201e6a5abb838fa34e8ff0174b015d36\",\"name\":\"LATB Staff\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"ja\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/8803277856c8b753feb4217dff0f9953327452df1a615c3c88b2f9864efb2ddd?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/8803277856c8b753feb4217dff0f9953327452df1a615c3c88b2f9864efb2ddd?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/8803277856c8b753feb4217dff0f9953327452df1a615c3c88b2f9864efb2ddd?s=96&d=mm&r=g\",\"caption\":\"LATB Staff\"},\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/author\\\/latbstaff\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"\u57f9\u990a\u7d30\u80de\u306b\u304a\u3051\u308bsiRNA\u306e\u5c0e\u5165\u3092\u6700\u9069\u5316\u3059\u308bTips\u30c8\u30c3\u30d710\u3010\u524d\u7de8\u3011 - Learning at the Bench","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/transfectiontips-1\/","og_locale":"ja_JP","og_type":"article","og_title":"\u57f9\u990a\u7d30\u80de\u306b\u304a\u3051\u308bsiRNA\u306e\u5c0e\u5165\u3092\u6700\u9069\u5316\u3059\u308bTips\u30c8\u30c3\u30d710\u3010\u524d\u7de8\u3011","og_description":"\u307f\u306a\u3055\u3093\u306f\u57f9\u990a\u7d30\u80de\u3092\u6271\u3046\u4e2d\u3067\u3001\u30c8\u30e9\u30f3\u30b9\u30d5\u30a7\u30af\u30b7\u30e7\u30f3\u306b\u304a\u56f0\u308a\u3067\u306f\u306a\u3044\u3067\u3057\u3087\u3046\u304b\uff1f \u672c\u8a18\u4e8b\u3067\u306f\u3001\u591a\u304f\u306e\u4eba\u304c\u5229\u7528\u3059\u308b\u30c8\u30e9\u30f3\u30b9\u30d5\u30a7\u30af\u30b7\u30e7\u30f3\u306e\u6700\u9069\u5316\u306b\u5f79\u7acb\u3064\u8981\u7d2010\u70b9\uff08\u4eca\u56de\u306f1~5\u306e\u4e0b\u8a185\u70b9\uff09\u306b\u3064\u3044\u3066\u7d39\u4ecb\u3044\u305f\u3057\u307e\u3059\u3002 &nbsp;","og_url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/transfectiontips-1\/","og_site_name":"Learning at the Bench","article_publisher":"https:\/\/www.facebook.com\/ThermoFisherJapan","article_published_time":"2018-04-26T00:00:00+00:00","article_modified_time":"2024-12-25T07:22:16+00:00","og_image":[{"width":1200,"height":630,"url":"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/COL04097-iStock-15956581-XXXLARGE-1.jpg","type":"image\/jpeg"}],"author":"LATB Staff","twitter_card":"summary_large_image","twitter_creator":"@ThermoFisherJP","twitter_site":"@ThermoFisherJP","twitter_misc":{"\u57f7\u7b46\u8005":"LATB Staff","\u63a8\u5b9a\u8aad\u307f\u53d6\u308a\u6642\u9593":"5\u5206"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/transfectiontips-1\/#article","isPartOf":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/transfectiontips-1\/"},"author":{"name":"LATB Staff","@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#\/schema\/person\/201e6a5abb838fa34e8ff0174b015d36"},"headline":"\u57f9\u990a\u7d30\u80de\u306b\u304a\u3051\u308bsiRNA\u306e\u5c0e\u5165\u3092\u6700\u9069\u5316\u3059\u308bTips\u30c8\u30c3\u30d710\u3010\u524d\u7de8\u3011","datePublished":"2018-04-26T00:00:00+00:00","dateModified":"2024-12-25T07:22:16+00:00","mainEntityOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/transfectiontips-1\/"},"wordCount":25,"commentCount":0,"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/transfectiontips-1\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/COL04097-iStock-15956581-XXXLARGE-1.jpg","keywords":["\u30c8\u30e9\u30f3\u30b9\u30d5\u30a7\u30af\u30b7\u30e7\u30f3"],"articleSection":["\u7d30\u80de\u57f9\u990a\u30fb\u30a4\u30e1\u30fc\u30b8\u30f3\u30b0"],"inLanguage":"ja","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/transfectiontips-1\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/transfectiontips-1\/","url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/transfectiontips-1\/","name":"\u57f9\u990a\u7d30\u80de\u306b\u304a\u3051\u308bsiRNA\u306e\u5c0e\u5165\u3092\u6700\u9069\u5316\u3059\u308bTips\u30c8\u30c3\u30d710\u3010\u524d\u7de8\u3011 - Learning at the Bench","isPartOf":{"@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/transfectiontips-1\/#primaryimage"},"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/transfectiontips-1\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/COL04097-iStock-15956581-XXXLARGE-1.jpg","datePublished":"2018-04-26T00:00:00+00:00","dateModified":"2024-12-25T07:22:16+00:00","author":{"@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#\/schema\/person\/201e6a5abb838fa34e8ff0174b015d36"},"breadcrumb":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/transfectiontips-1\/#breadcrumb"},"inLanguage":"ja","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/transfectiontips-1\/"]}]},{"@type":"ImageObject","inLanguage":"ja","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/transfectiontips-1\/#primaryimage","url":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/COL04097-iStock-15956581-XXXLARGE-1.jpg","contentUrl":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/COL04097-iStock-15956581-XXXLARGE-1.jpg","width":1200,"height":630},{"@type":"BreadcrumbList","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/transfectiontips-1\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/"},{"@type":"ListItem","position":2,"name":"\u57f9\u990a\u7d30\u80de\u306b\u304a\u3051\u308bsiRNA\u306e\u5c0e\u5165\u3092\u6700\u9069\u5316\u3059\u308bTips\u30c8\u30c3\u30d710\u3010\u524d\u7de8\u3011"}]},{"@type":"WebSite","@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#website","url":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/","name":"Learning at the Bench","description":"","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"ja"},{"@type":"Person","@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#\/schema\/person\/201e6a5abb838fa34e8ff0174b015d36","name":"LATB Staff","image":{"@type":"ImageObject","inLanguage":"ja","@id":"https:\/\/secure.gravatar.com\/avatar\/8803277856c8b753feb4217dff0f9953327452df1a615c3c88b2f9864efb2ddd?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/8803277856c8b753feb4217dff0f9953327452df1a615c3c88b2f9864efb2ddd?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/8803277856c8b753feb4217dff0f9953327452df1a615c3c88b2f9864efb2ddd?s=96&d=mm&r=g","caption":"LATB Staff"},"url":"https:\/\/admin.acceleratingscience.com\/author\/latbstaff\/"}]}},"taxonomy_info":{"category":[{"value":159,"label":"\u7d30\u80de\u57f9\u990a\u30fb\u30a4\u30e1\u30fc\u30b8\u30f3\u30b0"}],"post_tag":[{"value":67,"label":"\u30c8\u30e9\u30f3\u30b9\u30d5\u30a7\u30af\u30b7\u30e7\u30f3"}]},"featured_image_src_large":["https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/COL04097-iStock-15956581-XXXLARGE-1-1024x538.jpg",760,399,true],"author_info":{"display_name":"LATB Staff","author_link":"https:\/\/admin.acceleratingscience.com\/author\/latbstaff\/"},"comment_info":0,"category_info":[{"term_id":159,"name":"\u7d30\u80de\u57f9\u990a\u30fb\u30a4\u30e1\u30fc\u30b8\u30f3\u30b0","slug":"cell","term_group":0,"term_taxonomy_id":159,"taxonomy":"category","description":"","parent":0,"count":104,"filter":"raw","meta":[],"cat_ID":159,"category_count":104,"category_description":"","cat_name":"\u7d30\u80de\u57f9\u990a\u30fb\u30a4\u30e1\u30fc\u30b8\u30f3\u30b0","category_nicename":"cell","category_parent":0}],"tag_info":[{"term_id":67,"name":"\u30c8\u30e9\u30f3\u30b9\u30d5\u30a7\u30af\u30b7\u30e7\u30f3","slug":"transfection","term_group":0,"term_taxonomy_id":67,"taxonomy":"post_tag","description":"","parent":0,"count":17,"filter":"raw","meta":[]}],"jetpack-related-posts":[{"id":23864,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/protein-expression-cloning-bid-ts-mbr-25070\/","url_meta":{"origin":847,"position":0},"title":"\u521d\u5fc3\u8005\u3067\u3082\u5b89\u5fc3\uff01\u7c21\u5358\u306b\u3067\u304d\u308b\u767a\u73fe\u30d9\u30af\u30bf\u30fc\u306e\u4f5c\u308a\u65b9\uff1a\u4eba\u5de5\u907a\u4f1d\u5b50\u5408\u6210\u30b5\u30fc\u30d3\u30b9\u306e\u5229\u7528\u6cd5","author":"LatB Staff","date":"2025\u5e7411\u670813\u65e5","format":false,"excerpt":"\u30bf\u30f3\u30d1\u30af\u8cea\u767a\u73fe\u5b9f\u9a13\u306b\u306f\u767a\u73fe\u30d9\u30af\u30bf\u30fc\u304c\u6b20\u304b\u305b\u307e\u305b\u3093\u304c\u3001\u4e00\u304b\u3089\u4f5c\u308b\u3068\u306a\u308b\u3068\u3001\u304b\u306a\u308a\u306e\u624b\u9593\u3068\u7d4c\u9a13\u304c\u5fc5\u8981\u3067\u3059\u2026","rel":"","context":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","block_context":{"text":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/mol-bio\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/10\/protein-expression-cloning-bid-ts-mbr-25070_eyecatch.png?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/10\/protein-expression-cloning-bid-ts-mbr-25070_eyecatch.png?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/10\/protein-expression-cloning-bid-ts-mbr-25070_eyecatch.png?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/10\/protein-expression-cloning-bid-ts-mbr-25070_eyecatch.png?resize=700%2C400&ssl=1 2x"},"classes":[]},{"id":25723,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/cell-culture-basic-cell-culture-bpg-26031\/","url_meta":{"origin":847,"position":1},"title":"\u3010\u7b2c4\u56de\u3011CHO\u7d30\u80de\u682a\u958b\u767a\u3092\u3088\u308a\u8fc5\u901f\u306b\u2015\u9ad8\u751f\u7523\u6027\u30fb\u9577\u671f\u5b89\u5b9a\u6027\u30fb\u30b9\u30b1\u30fc\u30e9\u30d3\u30ea\u30c6\u30a3\u3092\u8a55\u4fa1\u3057\u305fCHOvantage GS CLD Kit","author":"LatB Staff","date":"2026\u5e7411\u67086\u65e5","format":false,"excerpt":"\u6297\u4f53\u533b\u85ac\u54c1\u306e\u958b\u767a\u3067\u306f\u3001\u76ee\u7684\u306e\u6297\u4f53\u3092\u300c\u305f\u304f\u3055\u3093\u4f5c\u308c\u308b\u300d\u7d30\u80de\u3092\u898b\u3064\u3051\u308b\u3060\u3051\u3067\u306f\u5341\u5206\u3067\u306f\u3042\u308a\u307e\u305b\u3093\u3002\u9ad8\u3044\u751f\u2026","rel":"","context":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","block_context":{"text":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/mol-bio\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/10\/cell-culture-basic-cell-culture-bpg-26031_eyecatch.png?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/10\/cell-culture-basic-cell-culture-bpg-26031_eyecatch.png?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/10\/cell-culture-basic-cell-culture-bpg-26031_eyecatch.png?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/10\/cell-culture-basic-cell-culture-bpg-26031_eyecatch.png?resize=700%2C400&ssl=1 2x"},"classes":[]},{"id":24152,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/cell-culture-protein-expression-bid-ts-mbr-25074\/","url_meta":{"origin":847,"position":2},"title":"\u30bf\u30f3\u30d1\u30af\u7523\u751f\u3084\u30a6\u30a4\u30eb\u30b9\u7523\u751f\u3092\u76ee\u7684\u3068\u3057\u305f\u9ad8\u5bc6\u5ea6\u7d30\u80de\u57f9\u990a\u30b7\u30b9\u30c6\u30e0\u5c0e\u5165\u306e\u7b2c\u4e00\u6b69\uff1a\u7d30\u80de\u682a\u306e\u7d99\u4ee3\u3068\u51cd\u7d50\u4fdd\u5b58\u7de8","author":"LatB Staff","date":"2025\u5e7412\u67083\u65e5","format":false,"excerpt":"\u9ad8\u5bc6\u5ea6\u7d30\u80de\u57f9\u990a\u30b7\u30b9\u30c6\u30e0\u3067\u306f\u3001\u5c02\u7528\u306e\u6d6e\u904a\u7d30\u80de\u682a\u3092\u7528\u3044\u3066\u6c7a\u3081\u3089\u308c\u305f\u624b\u9806\u3067\u57f9\u990a\u3057\u307e\u3059\u3002\u5b89\u5b9a\u7684\u306b\u904b\u7528\u3059\u308b\u305f\u3081\u2026","rel":"","context":"\u7d30\u80de\u57f9\u990a\u30fb\u30a4\u30e1\u30fc\u30b8\u30f3\u30b0","block_context":{"text":"\u7d30\u80de\u57f9\u990a\u30fb\u30a4\u30e1\u30fc\u30b8\u30f3\u30b0","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/cell\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/11\/cell-culture-protein-expression-bid-ts-mbr-25074_eycatch.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/11\/cell-culture-protein-expression-bid-ts-mbr-25074_eycatch.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/11\/cell-culture-protein-expression-bid-ts-mbr-25074_eycatch.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/11\/cell-culture-protein-expression-bid-ts-mbr-25074_eycatch.jpg?resize=700%2C400&ssl=1 2x"},"classes":[]},{"id":24108,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/cell-culture-cell-count-bid-ts-mbr-25065-2\/","url_meta":{"origin":847,"position":3},"title":"\u3010\u7b2c6\u56de\u3011 \u30a6\u30a7\u30b9\u30bf\u30f3\u30d6\u30ed\u30c3\u30c6\u30a3\u30f3\u30b0\u6cd5\u306b\u3088\u308b \u300e\u30a8\u30af\u30bd\u30bd\u30fc\u30e0\u4e2d\u306e\u30bf\u30f3\u30d1\u30af\u8cea\uff08Protein cargo\uff09\u300f\u306e\u89e3\u6790","author":"LatB Staff","date":"2026\u5e747\u670815\u65e5","format":false,"excerpt":"\u30a8\u30af\u30bd\u30bd\u30fc\u30e0\uff08\u30a8\u30ad\u30bd\u30bd\u30fc\u30e0\uff09\u306f\u3001\u7d30\u80de\u304b\u3089\u5206\u6ccc\u3055\u308c\u308b\u5c0f\u3055\u306a\u819c\u5c0f\u80de\u3067\u3001\u6838\u9178\uff08RNA\uff0fDNA\uff09\u3060\u3051\u3067\u306a\u304f\u3001\u2026","rel":"","context":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","block_context":{"text":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/mol-bio\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/11\/cell-culture-cell-count-bid-ts-mbr-25065_eyecatch.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/11\/cell-culture-cell-count-bid-ts-mbr-25065_eyecatch.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/11\/cell-culture-cell-count-bid-ts-mbr-25065_eyecatch.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/11\/cell-culture-cell-count-bid-ts-mbr-25065_eyecatch.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/11\/cell-culture-cell-count-bid-ts-mbr-25065_eyecatch.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/11\/cell-culture-cell-count-bid-ts-mbr-25065_eyecatch.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":25608,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/cell-culture-basic-cell-culture-bpg-26026\/","url_meta":{"origin":847,"position":4},"title":"\u3010\u7b2c3\u56de\u3011Gibco\u57f9\u5730 60\u5e74\u306e\u30a4\u30ce\u30d9\u30fc\u30b7\u30e7\u30f3\u3002\u7d30\u80de\u57f9\u990a\u306e\u6b74\u53f2\u306f\u57f9\u5730\u306e\u6b74\u53f2\u3002","author":"LatB Staff","date":"2026\u5e7410\u67087\u65e5","format":false,"excerpt":"\u3053\u306e\u30d6\u30ed\u30b0\u3067\u306f\u3001\u30d0\u30a4\u30aa\u30d7\u30ed\u30c0\u30af\u30b7\u30e7\u30f3\u30c1\u30fc\u30e0\u304c\u533b\u85ac\u54c1\u88fd\u9020\u306b\u95a2\u9023\u3059\u308b\u3055\u307e\u3056\u307e\u306a\u30c8\u30d4\u30c3\u30af\u3092\u30b7\u30ea\u30fc\u30ba\u3067\u3054\u7d39\u4ecb\u2026","rel":"","context":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","block_context":{"text":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/mol-bio\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/08\/cell-culture-basic-cell-culture-bpg-26026_eyecatch.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/08\/cell-culture-basic-cell-culture-bpg-26026_eyecatch.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/08\/cell-culture-basic-cell-culture-bpg-26026_eyecatch.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/08\/cell-culture-basic-cell-culture-bpg-26026_eyecatch.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/08\/cell-culture-basic-cell-culture-bpg-26026_eyecatch.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/08\/cell-culture-basic-cell-culture-bpg-26026_eyecatch.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":25540,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/cloning-cell-separation-bid-ts-mbr-26023\/","url_meta":{"origin":847,"position":5},"title":"\u5927\u8178\u83cc\u306e\u98fc\u3044\u65b92\uff5e\u5b9f\u969b\u306b\u57f9\u990a\u3057\u3066\u307f\u3088\u3046","author":"LatB Staff","date":"2026\u5e748\u670826\u65e5","format":false,"excerpt":"\u30d6\u30ed\u30b0\u300c\u5927\u8178\u83cc\u306e\u98fc\u3044\u65b9\uff5e\u5b9f\u9a13\u306b\u5fc5\u8981\u306a\u8a2d\u5099\u3092\u305d\u308d\u3048\u3088\u3046\u300d\u3067\u306f\u3001\u30af\u30ed\u30fc\u30cb\u30f3\u30b0\u3084\u7d44\u307f\u63db\u3048\u30bf\u30f3\u30d1\u30af\u8cea\u767a\u73fe\u306e\u7528\u2026","rel":"","context":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","block_context":{"text":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/mol-bio\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/08\/cloning-cell-separation-bid-ts-mbr-26023_eyecatch.png?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/08\/cloning-cell-separation-bid-ts-mbr-26023_eyecatch.png?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/08\/cloning-cell-separation-bid-ts-mbr-26023_eyecatch.png?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/08\/cloning-cell-separation-bid-ts-mbr-26023_eyecatch.png?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/08\/cloning-cell-separation-bid-ts-mbr-26023_eyecatch.png?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/08\/cloning-cell-separation-bid-ts-mbr-26023_eyecatch.png?resize=1400%2C800&ssl=1 4x"},"classes":[]}],"jetpack_sharing_enabled":true,"amp_enabled":true,"jetpack_featured_media_url":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/COL04097-iStock-15956581-XXXLARGE-1.jpg","_links":{"self":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/posts\/847","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/users\/988"}],"replies":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/comments?post=847"}],"version-history":[{"count":0,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/posts\/847\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/media\/3622"}],"wp:attachment":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/media?parent=847"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/categories?post=847"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/tags?post=847"},{"taxonomy":"division","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/division?post=847"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}