{"id":853,"date":"2018-05-21T00:00:00","date_gmt":"2018-05-21T00:00:00","guid":{"rendered":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/rna-purification2\/"},"modified":"2024-12-25T16:20:18","modified_gmt":"2024-12-25T07:20:18","slug":"rna-purification2","status":"publish","type":"post","link":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/rna-purification2\/","title":{"rendered":"RNA\u7cbe\u88fd\u3067\u6ce8\u610f\u3059\u3079\u304d\u30c6\u30af\u30cb\u30c3\u30af -\u305d\u306e2-"},"content":{"rendered":"<p>RNA\u306e\u8abf\u6574\u30fb\u7cbe\u88fd\u306f\u3001\u6b21\u4e16\u4ee3\u30b7\u30fc\u30b1\u30f3\u30b7\u30f3\u30b0\u3001\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u306b\u3088\u308b\u767a\u73fe\u5b9a\u91cf\uff08RT-qPCR\uff09\u3001\u30ce\u30fc\u30b6\u30f3\u30d6\u30ed\u30c3\u30c8\u5206\u6790\u3084cRNA\u5408\u6210\u306a\u3069\u3001\u3055\u307e\u3056\u307e\u306a\u5b9f\u9a13\u306b\u5fc5\u8981\u3068\u306a\u308b\u57fa\u672c\u7684\u306a\u6280\u8853\u3067\u3059\u3002<\/p>\n<p><strong>\u3057\u304b\u3057\u306a\u304c\u3089RNA\u306e\u8abf\u88fd\u306e\u30b9\u30c6\u30c3\u30d7\u306f\u3001\u56de\u53ce\u3055\u308c\u308bRNA\u306e\u30d7\u30ed\u30d5\u30a1\u30a4\u30ea\u30f3\u30b0\u306e\u7dad\u6301\u3084\u3001RNA\u306e\u7d14\u5ea6\u3001\u53ce\u91cf\u306a\u3069\u3001\u4ee5\u5f8c\u306e\u5206\u6790\u7d50\u679c\u306b\u5927\u304d\u306a\u5f71\u97ff\u3092\u53ca\u307c\u3059\u3053\u3068\u304c\u77e5\u3089\u308c\u3066\u3044\u307e\u3059\u3002<\/strong><\/p>\n<p>\u672c\u30c8\u30d4\u30c3\u30af\u3067\u306f\u3001\u5b9f\u9a13\u5ba4\u3067\u306eRNA\u8abf\u88fd\u306e\u305f\u3081\u306b\u5fc5\u8981\u306a10\u306e\u6ce8\u610f\u70b9\u3092\u7d39\u4ecb\u3057\u3066\u304a\u308a\u3001\u300c<a href=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/RNA-purification1\/?cid=bid_sap_nap_r04_jp_cp0000_pjt0000_bid00000_0so_blg_op_awa_oc_s00_nap2_Social_LAB\" target=\"_blank\" rel=\"noopener\">RNA\u7cbe\u88fd\u3092\u6539\u5584\u3059\u308b\u65b9\u6cd5 -\u305d\u306e1-<\/a>\u300d\u306b\u7d9a\u304f\u6b8b\u308a\u306e5\u3064\u306e\u6ce8\u610f\u70b9(6~10)\u306b\u3064\u3044\u3066\u7d39\u4ecb\u3057\u307e\u3059\u3002<\/p>\n<p>\u307e\u3060\u305d\u306e1\u3092\u8aad\u3093\u3067\u3044\u306a\u3044\u65b9\u306f<a href=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/RNA-purification1\/?cid=bid_sap_nap_r04_jp_cp0000_pjt0000_bid00000_0so_blg_op_awa_oc_s00_nap2_Social_LAB\" target=\"_blank\" rel=\"noopener\">\u3053\u3061\u3089<\/a><\/p>\n<h1>6. DNase\u51e6\u7406<\/h1>\n<p>RNA\u3092RT-PCR\u30d9\u30fc\u30b9\u306e\u89e3\u6790\u6cd5\u3067\u89e3\u6790\u3059\u308b\u5834\u5408\u3001RNA\u30b5\u30f3\u30d7\u30eb\u4e2d\u306b\u6b8b\u5b58\u3059\u308bgDNA\uff08\u30b2\u30ce\u30e0DNA\uff09\u3092\u9664\u53bb\u3059\u308b\u305f\u3081\u306bDNase\u51e6\u7406\u3092\u884c\u3046\u3053\u3068\u3092\u304a\u52e7\u3081\u3057\u307e\u3059\u3002\u7279\u306b\u813e\u81d3\u306e\u3088\u3046\u306aDNA\u304c\u591a\u3044\u7d44\u7e54\u304b\u3089RNA\u3092\u62bd\u51fa\u3059\u308b\u5834\u5408\u306f\u3001DNase\u51e6\u7406\u3092\u5fc5\u305a\u884c\u3063\u3066\u304f\u3060\u3055\u3044\u3002<\/p>\n<p><a href=\"http:\/\/www.thermofisher.com\/order\/catalog\/product\/12185010?CID=bid_sap_nap_r04_jp_cp0000_pjt0000_bid00000_0so_blg_op_awa_oc_s00_nap2_Social_LAB\" target=\"_blank\" rel=\"noopener\">PureLink\u2122 DNase Set<\/a>\u306f\u3001\u30aa\u30f3\u30ab\u30e9\u30e0\u3067DNA\u3092\u52b9\u679c\u7684\u306b\u9664\u53bb\u3059\u308b\u306e\u306b\u6700\u9069\u5316\u3055\u308c\u305f\u30ad\u30c3\u30c8\u3067\u3042\u308a\u3001PureLink\u2122 RNA Mini Kit\u3084TRIzol\u2122 Plus RNA Purification Kit\u306a\u3069\u30b9\u30d4\u30f3\u30ab\u30e9\u30e0\u3092\u7528\u3044\u305f\u7cbe\u88fd\u30b7\u30b9\u30c6\u30e0\u3068\u7d44\u307f\u5408\u308f\u305b\u3066\u4f7f\u7528\u3057\u307e\u3059\u3002<\/p>\n<p>\u307e\u305f\u7cbe\u88fd\u5f8c\u306eRNA\u30b5\u30f3\u30d7\u30eb\u518d\u61f8\u6fc1\u7528\u306e<a href=\"http:\/\/www.thermofisher.com\/order\/catalog\/product\/AM1907?CID=bid_sap_nap_r04_jp_cp0000_pjt0000_bid00000_0so_blg_op_awa_oc_s00_nap2_Social_LAB\" target=\"_blank\" rel=\"noopener\">TURBO DNA-free\u2122 DNase<\/a>\u306f\u3001\u3055\u307e\u3056\u307eRNA\u7cbe\u88fd\u30b7\u30b9\u30c6\u30e0\u3067\u56de\u53ce\u3057\u305fRNA\u306b\u5229\u7528\u53ef\u80fd\u3067\u3059\u3002Kit\u306b\u306f\u5f37\u529b\u306aTURBO DNase\u3068\u53cd\u5fdc\u7d42\u4e86\u5f8c\u306e\u593e\u96d1\u6210\u5206\u3092\u9664\u53bb\u3059\u308bRemoval reagent\u304c\u30bb\u30c3\u30c8\u3055\u308c\u3066\u3044\u307e\u3059\u3002<\/p>\n<p>\u4e21\u88fd\u54c1\u3068\u3082\u306b\u3001\u9ad8\u54c1\u8cea\u306eDNase I\u3068\u6700\u9069\u5316\u3055\u308c\u305f\u53cd\u5fdc\u7de9\u885d\u6db2\u304c\u30bb\u30c3\u30c8\u306b\u306a\u3063\u3066\u304a\u308a\u3001\u77ed\u6642\u9593\u3067\u7c21\u5358\u306b\u3001\u304b\u3064DNase\u306e\u4e0d\u6d3b\u6027\u5316\u306e\u305f\u3081\u306e\u6709\u6a5f\u6eb6\u5a92\u51e6\u7406\u3084\u71b1\u51e6\u7406\u306e\u5fc5\u8981\u304c\u3042\u308a\u307e\u305b\u3093\u3002<\/p>\n<h1>7. RNase-free\u306e\u74b0\u5883\u3092\u6574\u3048\u308b<\/h1>\n<p>\u81ea\u7136\u754c\u306b\u306f\u3042\u3089\u3086\u308b\u5834\u6240\u306bRNase\u304c\u5b58\u5728\u3059\u308b\u305f\u3081\u3001RNA\u306e\u5b9f\u9a13\u3092\u59cb\u3081\u308b\u524d\u306b\u30e9\u30dc\u74b0\u5883\u3092\u3057\u3063\u304b\u308a\u30c1\u30a7\u30c3\u30af\u3057\u307e\u3057\u3087\u3046\u3002\u7279\u306b\u7cbe\u88fd\u5f8c\u306eRNA\u306b\u76f4\u63a5\u89e6\u308c\u308b\u53ef\u80fd\u6027\u306e\u3042\u308b\u3082\u306e\u306f\u3059\u3079\u3066RNase-free\u306b\u3059\u308b\u5fc5\u8981\u304c\u3042\u308a\u307e\u3059\u3002\u307e\u305a\u306f\u5c11\u306a\u304f\u3068\u3082\u4ee5\u4e0b\u306e\u70b9\u306b\u3064\u3044\u3066\u78ba\u8a8d\u3057\u3066\u304f\u3060\u3055\u3044\uff1a<\/p>\n<ul>\n<li>\u5b9f\u9a13\u53f0\u3084\u5668\u5177\u8868\u9762\u306eRNase-free\u51e6\u7406<\/li>\n<\/ul>\n<p>\u7814\u7a76\u5ba4\u306e\u30d9\u30f3\u30c1\u30c8\u30c3\u30d7\u3084\u30ac\u30e9\u30b9\u5668\u5177\u3001\u30d7\u30e9\u30b9\u30c1\u30c3\u30af\u3084\u305d\u306e\u4ed6\u306e\u5668\u5177\u306f\u8868\u9762\u304c\u5916\u90e8\u306e\u74b0\u5883\u306b\u3055\u3089\u3055\u308c\u3066\u3044\u308b\u305f\u3081\u3001\u3053\u308c\u3089\u306e\u5668\u5177\u306b\u4ed8\u7740\u3057\u305fRNase\u304c\u91cd\u8981\u306a\u5b9f\u9a13\u7cfb\u3078\u306eRNase\u30b3\u30f3\u30bf\u30df\u306e\u539f\u56e0\u306b\u306a\u308b\u5834\u5408\u304c\u3042\u308a\u307e\u3059\u3002\u3053\u3046\u3057\u305f\u5668\u5177\u8868\u9762\u306b\u4ed8\u7740\u3059\u308bRNase\u306f\u3001\u30e9\u30dc\u74b0\u5883\u306b\u304a\u3044\u3066\u3082\u30d0\u30af\u30c6\u30ea\u30a2\u3084\u771f\u83cc\u80de\u5b50\u7531\u6765\u306b\u3088\u308b\u5834\u5408\u304c\u591a\u304f\u3001\u30d2\u30c8\u306e\u76ae\u819a\u8868\u9762\u304b\u3089\u8131\u843d\u3057\u305f\u6b7b\u7d30\u80de\u304c\u539f\u56e0\u306e\u5834\u5408\u3082\u3042\u308a\u307e\u3059\u3002\u3053\u306e\u69d8\u306a\u30d9\u30f3\u30c1\u30c8\u30c3\u30d7\u3084\u5668\u5177\u8868\u9762\u306eRNase\u9664\u53bb\u51e6\u7406\u306f\u3001<a href=\"\/\/www.thermofisher.com\/order\/catalog\/product\/AM9780?CID=Social_LAB\" target=\"_blank\" rel=\"noopener\">RNaseZap\u2122 RNase Decontamination Solution<\/a>\u3084<a href=\"https:\/\/www.thermofisher.com\/order\/catalog\/product\/AM9786?CID=bid_sap_nap_r04_jp_cp0000_pjt0000_bid00000_0so_blg_op_awa_oc_s00_nap2_Social_LAB\" target=\"_blank\" rel=\"noopener\">RNaseZap\u2122 RNase Decontamination Wipes<\/a>\u3092\u7528\u3044\u308c\u3070\u7c21\u5358\u306b\u884c\u3048\u307e\u3059\u3002<\/p>\n<ul>\n<li>RNA\u3092\u6271\u3046\u969b\u306e\u6ce8\u610f<\/li>\n<\/ul>\n<p>\u5e38\u306bRNase\u30d5\u30ea\u30fc\u306e\u30c1\u30c3\u30d7\u3001\u30c1\u30e5\u30fc\u30d6\u304a\u3088\u3073\u8a66\u85ac\u3092\u4f7f\u7528\u3057\u3001\u5b9f\u9a13\u4e2d\u306b\u624b\u888b\u3092\u983b\u7e41\u306b\u4ea4\u63db\u3059\u308b\u3053\u3068\u3082\u5927\u5207\u3067\u3059\u3002<\/p>\n<h1>8. \u9069\u5207\u306a\u30a8\u30bf\u30ce\u30fc\u30eb\u6c88\u6bbf\u306e\u65b9\u6cd5<\/h1>\n<p>RNA\u7cbe\u88fd\u5f8c\u3001\u6fc3\u7e2e\u306a\u3069\u306e\u76ee\u7684\u3067\u30a8\u30bf\u30ce\u30fc\u30eb\u6c88\u6bbf\u3092\u884c\u3046\u5834\u5408\u304c\u3042\u308a\u307e\u3059\u3002\u64cd\u4f5c\u306b\u4f34\u3046RNA\u306e\u30ed\u30b9\u3092\u6700\u5c0f\u9650\u306b\u6291\u3048\u308b\u305f\u3081\u306b\u3001\u6b63\u3057\u3044\u64cd\u4f5c\u304c\u5fc5\u8981\u3067\u3059\u3002<\/p>\n<p>\u4ee5\u4e0b\u3092\u78ba\u8a8d\u3057\u3066\u304f\u3060\u3055\u3044\u3002<\/p>\n<ul>\n<li>\u5fc5\u8981\u306a\u7269\n<ul>\n<li>\u30a2\u30eb\u30b3\u30fc\u30eb\uff08\u30a8\u30bf\u30ce\u30fc\u30eb\u307e\u305f\u306f\u30a4\u30bd\u30d7\u30ed\u30d1\u30ce\u30fc\u30eb\uff09\u3067RNA\u3092\u6c88\u6bbf\u3055\u305b\u308b\u305f\u3081\u306e\u6700\u5c0f\u6fc3\u5ea6\u306e1\u4fa1\u967d\u30a4\u30aa\u30f3\uff080.2 M Na+\u3001K+\u304a\u3088\u30730.5 M NH4+\u306a\u3069\uff09<\/li>\n<\/ul>\n<\/li>\n<li>\u4e3b\u306a\u30ef\u30fc\u30af\u30d5\u30ed\u30fc\n<ul>\n<li>\u6700\u7d42\u6fc3\u5ea6\u304c5M\u306b\u306a\u308b\u3088\u3046\u306b\u9162\u9178\u30a2\u30f3\u30e2\u30cb\u30a6\u30e0\u3092RNA\u30b5\u30f3\u30d7\u30eb\u306b\u6dfb\u52a0\u5f8c\u3001\u6eb6\u6db2\u306e2.5\u500d\u5bb9\u91cf\u306e\u30a8\u30bf\u30ce\u30fc\u30eb(\u30a4\u30bd\u30d7\u30ed\u30d1\u30ce\u30fc\u30eb\u306e\u5834\u5408\u306f\u7b49\u91cf)\u3092\u6dfb\u52a0\u3057\u3001\u3088\u304f\u30df\u30c3\u30af\u30b9\u3057\u307e\u3059\u3002\u307e\u305f-20\u2103\u306715\u5206\u9593\u4ee5\u4e0a\u51b7\u5374\u3059\u308b\u3053\u3068\u306b\u3088\u308a\u3001RNA\u306e\u56de\u53ce\u52b9\u7387\u304c\u9ad8\u304f\u306a\u308a\u307e\u3059\u3002<\/li>\n<li>\u51b7\u5374\u5f8c\u3001RNA\u309212,000 x g\u306710\u5206\u9593\u9060\u5fc3\u3057\u3001\u614e\u91cd\u306b\u4e0a\u6e05\u3092\u9664\u53bb\u3057\u307e\u3059\u3002<\/li>\n<li>\u5fae\u91cf\u306aRNA\uff08ng\/mL\uff09\u3092\u5b89\u5b9a\u7684\u306b\u56de\u53ce\u3059\u308b\u305f\u3081\u306b\u306f\u3001\u5171\u6c88\u6bbf\u5264\uff08\u30b0\u30ea\u30b3\u30fc\u30b2\u30f3\u3001\u9175\u6bcdRNA\u307e\u305f\u306f\u30ea\u30cb\u30a2\u30a2\u30af\u30ea\u30eb\u30a2\u30df\u30c9\u306a\u3069\uff09\u3092\u4f7f\u7528\u3059\u308b\u5fc5\u8981\u304c\u3042\u308a\u307e\u3059\u3002\u30ea\u30cb\u30a2\u30a2\u30af\u30ea\u30eb\u30a2\u30df\u30c9\u3084DNase\u51e6\u7406\u3055\u308c\u305f\u30b0\u30ea\u30b3\u30fc\u30b2\u30f3\u306f\u3001RNA\u3078\u306eDNA\u306e\u30b3\u30f3\u30bf\u30df\u30cd\u30fc\u30b7\u30e7\u30f3\u304c\u306a\u3044\u305f\u3081\u3001RT-PCR\u30d9\u30fc\u30b9\u306e\u30a2\u30d7\u30ea\u30b1\u30fc\u30b7\u30e7\u30f3\u306b\u9069\u3057\u305f\u5171\u6c88\u6bbf\u5264\u3068\u8a00\u3048\u307e\u3059\u3002\u307e\u305f\u3001\u9175\u6bcdtRNA\u304a\u3088\u3073DNase\u672a\u51e6\u7406\u306e\u30b0\u30ea\u30b3\u30fc\u30b2\u30f3\u306f\u3001\u30b5\u30f3\u30d7\u30eb\u3078\u306e\u6838\u9178\u306e\u30b3\u30f3\u30bf\u30df\u306e\u539f\u56e0\u3068\u306a\u308b\u305f\u3081\u3001RT-PCR\u30d9\u30fc\u30b9\u306e\u30a2\u30d7\u30ea\u30b1\u30fc\u30b7\u30e7\u30f3\u306e\u7d50\u679c\u306b\u60aa\u5f71\u97ff\u3092\u4e0e\u3048\u308b\u53ef\u80fd\u6027\u304c\u3042\u308a\u307e\u3059\u3002<\/li>\n<li>\u4e0a\u6e05\u3092\u9664\u53bb\u5f8c\u300170\uff05\u30a8\u30bf\u30ce\u30fc\u30eb\u306b\u3088\u308b\u30ea\u30f3\u30b9\u3092\u884c\u3044\u3001\u904e\u5270\u306a\u5869\u3092\u9664\u304d\u307e\u3059\u3002<strong>\u306a\u304aRNA\u30da\u30ec\u30c3\u30c8\u306f\u30a8\u30bf\u30ce\u30fc\u30eb\u3092\u6c17\u5316\u3055\u305b\u3066\u304b\u3089\u6eb6\u89e3\u3057\u307e\u3059\u304c\u3001RNA\u3092\u4e7e\u71e5\u3055\u305b\u3059\u304e\u308b\u3068\u518d\u61f8\u6fc1\u304c\u56f0\u96e3\u306b\u306a\u308b\u305f\u3081\u3001\u6ce8\u610f\u3057\u3066\u304f\u3060\u3055\u3044\u3002<\/strong><\/li>\n<\/ul>\n<\/li>\n<\/ul>\n<h1>9. RNA\u306e\u6eb6\u89e3<\/h1>\n<p>\u7cbe\u88fdRNA\u30da\u30ec\u30c3\u30c8\u3092\u518d\u6eb6\u89e3\u3059\u308b\u969b\u306b\u306f\u3001\u4ee5\u4e0b\u306e3\u70b9\u306b\u3054\u6ce8\u610f\u304f\u3060\u3055\u3044\u3002<\/p>\n<ul>\n<li>Buffer\u306f\u3001RNase-free\u3067\u3042\u308b<\/li>\n<li>\u5f31\u9178\u6027\u306epH\uff08pH 6\uff5e7\uff09\u4e2d\u3067\u306fRNA\u304c\u3088\u308a\u5b89\u5b9a<\/li>\n<li>RNase\u306e\u30b3\u30f3\u30bf\u30df\u30cd\u30fc\u30b7\u30e7\u30f3\u306e\u5bfe\u7b56\u3068\u3057\u3066\u3001\u4f4e\u6fc3\u5ea6\u306e\u30ad\u30ec\u30fc\u30c8\u5264\uff08EDTA\u306a\u3069\uff09\u3092\u6dfb\u52a0\u3059\u308b<\/li>\n<\/ul>\n<p><a href=\"http:\/\/www.thermofisher.com\/order\/catalog\/product\/AM7001?CID=bid_sap_nap_r04_jp_cp0000_pjt0000_bid00000_0so_blg_op_awa_oc_s00_nap2_Social_LAB\" target=\"_blank\" rel=\"noopener\">THE RNA Storage Solution<\/a>\u306f\u3053\u308c\u30893\u3064\u306e\u57fa\u6e96\u306e\u3059\u3079\u3066\u3092\u6e80\u305f\u3057\u305fRNA\u4fdd\u5b58\u7528\u306ebuffer\u3067\u3059\u3002<\/p>\n<h1>10. \u7cbe\u88fd\u5f8c\u306eRNA\u306e\u4fdd\u5b58<\/h1>\n<p>\u7cbe\u88fdRNA\u306e\u4fdd\u5b58\u306f\u3001<strong>\u77ed\u671f\u9593\u3067\u3042\u308c\u3070buffer\u307e\u305f\u306fRNase-free water\u306b\u6eb6\u89e3\u3057\u305f\u72b6\u614b\u3067\u3001-20\u2103\u3067\u4fdd\u5b58\u3067\u304d\u307e\u3059<\/strong>\u3002<\/p>\n<p>\u3057\u304b\u3057\u306a\u304c\u3089<strong>\u9577\u671f\u4fdd\u5b58\u3059\u308b\u5834\u5408\u306f-80\u2103\u3067\u4fdd\u5b58\u3057\u307e\u3059<\/strong>\u3002buffer\u307e\u305f\u306fRNase-free water\u306b\u6eb6\u89e3\u3057\u305f\u72b6\u614b\u3067\u306e\u4fdd\u5b58\u3082\u53ef\u80fd\u3067\u3059\u304c\u3001<strong>\u30a8\u30bf\u30ce\u30fc\u30eb\u6c88\u6bbf\u306e\u72b6\u614b\uff08RNA\u30b5\u30f3\u30d7\u30eb\u306b\u6700\u7d42\u6fc3\u5ea6\u304c0.5M\u306b\u306a\u308b\u3088\u3046\u306b\u9162\u9178\u30a2\u30f3\u30e2\u30cb\u30a6\u30e0\u3092\u6dfb\u52a0\u5f8c\u30012.5\u500d\u5bb9\u91cf\u306e\u30a8\u30bf\u30ce\u30fc\u30eb\u3092\u6dfb\u52a0\u3057\u3066\u30df\u30c3\u30af\u30b9\u3057\u305f\u72b6\u614b\uff09\u3067-80\u2103\u3067\u306e\u4fdd\u5b58\u304c\u6700\u3082RNA\u304c\u5b89\u5b9a\u3067\u3059\u3002<\/strong><\/p>\n<p>\u307e\u305fRNA\u6eb6\u6db2\u306f\u3001\u5c0f\u5206\u3051\u3057\u3066\u4fdd\u5b58\u3059\u308b\u3053\u3068\u3092\u304a\u52e7\u3081\u3057\u307e\u3059\u3002\u3053\u308c\u306f\u51cd\u7d50\u878d\u89e3\u30b5\u30a4\u30af\u30eb\u3092\u6291\u3048\u308b\u3053\u3068\u3067RNA\u306e\u30c0\u30e1\u30fc\u30b8\u3092\u9632\u304e\u3001\u3055\u3089\u306b\u306fRNase\u306e\u30b3\u30f3\u30bf\u30df\u30cd\u30fc\u30b7\u30e7\u30f3\u306e\u30ea\u30b9\u30af\u3092\u6700\u5c0f\u9650\u306b\u6291\u3048\u308b\u3053\u3068\u304c\u3067\u304d\u308b\u304b\u3089\u3067\u3059\u3002<\/p>\n<p>&nbsp;<\/p>\n<h2>\u3010\u7121\u6599\u30c0\u30a6\u30f3\u30ed\u30fc\u30c9\u3011Gibco\u7d30\u80de\u57f9\u990a\u57fa\u790e\u30cf\u30f3\u30c9\u30d6\u30c3\u30af<\/h2>\n<p>\u7d30\u80de\u57f9\u990a\u306b\u95a2\u3059\u308b\u57fa\u790e\u60c5\u5831\u3092\u89e3\u8aac\u3057\u305f\u30cf\u30f3\u30c9\u30d6\u30c3\u30af\u3092\u3054\u7528\u610f\u3057\u3066\u3044\u307e\u3059\uff08\u65e5\u672c\u8a9e\u7248\u3001\u7d04100\u30da\u30fc\u30b8\uff09\u3002PDF\u30d5\u30a1\u30a4\u30eb\u306e\u30c0\u30a6\u30f3\u30ed\u30fc\u30c9\u3092\u3054\u5e0c\u671b\u306e\u65b9\u306f\u3001\u4e0b\u8a18\u30dc\u30bf\u30f3\u3088\u308a\u304a\u7533\u3057\u8fbc\u307f\u304f\u3060\u3055\u3044\u3002<\/p>\n<p><a class=\"btn btn-red\" href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/global\/forms\/gibco-cell-culture-basics-handbook-form.html?CID=bid_sap_nap_r04_jp_cp0000_pjt0000_bid00000_0so_blg_op_awa_oc_s00_nap2_Social_LAB\" target=\"_blank\" rel=\"noopener noreferrer\">\u30c0\u30a6\u30f3\u30ed\u30fc\u30c9\u3059\u308b<\/a><\/p>\n<p>&nbsp;<\/p>\n<p>\u7814\u7a76\u7528\u306b\u306e\u307f\u4f7f\u7528\u3067\u304d\u307e\u3059\u3002\u8a3a\u65ad\u76ee\u7684\u304a\u3088\u3073\u305d\u306e\u624b\u7d9a\u304d\u4e0a\u3067\u306e\u4f7f\u7528\u306f\u3067\u304d\u307e\u305b\u3093\u3002<\/p>\n","protected":false},"excerpt":{"rendered":"<p>RNA\u306e\u8abf\u6574\u30fb\u7cbe\u88fd\u306f\u3001\u6b21\u4e16\u4ee3\u30b7\u30fc\u30b1\u30f3\u30b7\u30f3\u30b0\u3001\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u306b\u3088\u308b\u767a\u73fe\u5b9a\u91cf\uff08RT-qPCR\uff09\u3001\u30ce\u30fc\u30b6\u30f3\u30d6\u30ed\u30c3\u30c8\u5206\u6790\u3084cRNA\u5408\u6210\u306a\u3069\u3001\u3055\u307e\u3056\u307e\u306a\u5b9f\u9a13\u306b\u5fc5\u8981\u3068\u306a\u308b\u57fa\u672c\u7684\u306a\u6280\u8853\u3067\u3059\u3002 \u3057\u304b\u3057\u306a\u304c\u3089RNA\u306e\u8abf\u88fd\u306e\u30b9\u30c6\u30c3\u30d7\u306f\u3001<\/p>\n","protected":false},"author":988,"featured_media":3628,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_monsterinsights_skip_tracking":false,"_genesis_hide_title":false,"_genesis_hide_breadcrumbs":false,"_genesis_hide_singular_image":false,"_genesis_hide_footer_widgets":false,"_genesis_custom_body_class":"","_genesis_custom_post_class":"","_genesis_layout":"","_jetpack_newsletter_access":"","_jetpack_dont_email_post_to_subs":false,"_jetpack_newsletter_tier_id":0,"_jetpack_memberships_contains_paywalled_content":false,"_jetpack_feature_clip_id":0,"_jetpack_memberships_contains_paid_content":false,"footnotes":"","jetpack_post_was_ever_published":false},"categories":[159],"tags":[77],"division":[],"class_list":["post-853","post","type-post","status-publish","format-standard","has-post-thumbnail","category-cell","tag-nucleic-acid-purification","entry"],"_selected_authors":"","_selected_reviewers":"","acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v27.8 (Yoast SEO v27.8) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>RNA\u7cbe\u88fd\u3067\u6ce8\u610f\u3059\u3079\u304d\u30c6\u30af\u30cb\u30c3\u30af -\u305d\u306e2- Learning at the Bench<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/rna-purification2\/\" \/>\n<meta property=\"og:locale\" content=\"ja_JP\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"RNA\u7cbe\u88fd\u3067\u6ce8\u610f\u3059\u3079\u304d\u30c6\u30af\u30cb\u30c3\u30af -\u305d\u306e2-\" \/>\n<meta property=\"og:description\" content=\"RNA\u306e\u8abf\u6574\u30fb\u7cbe\u88fd\u306f\u3001\u6b21\u4e16\u4ee3\u30b7\u30fc\u30b1\u30f3\u30b7\u30f3\u30b0\u3001\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u306b\u3088\u308b\u767a\u73fe\u5b9a\u91cf\uff08RT-qPCR\uff09\u3001\u30ce\u30fc\u30b6\u30f3\u30d6\u30ed\u30c3\u30c8\u5206\u6790\u3084cRNA\u5408\u6210\u306a\u3069\u3001\u3055\u307e\u3056\u307e\u306a\u5b9f\u9a13\u306b\u5fc5\u8981\u3068\u306a\u308b\u57fa\u672c\u7684\u306a\u6280\u8853\u3067\u3059\u3002 \u3057\u304b\u3057\u306a\u304c\u3089RNA\u306e\u8abf\u88fd\u306e\u30b9\u30c6\u30c3\u30d7\u306f\u3001\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/rna-purification2\/\" \/>\n<meta property=\"og:site_name\" content=\"Learning at the Bench\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/ThermoFisherJapan\" \/>\n<meta property=\"article:published_time\" content=\"2018-05-21T00:00:00+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2024-12-25T07:20:18+00:00\" \/>\n<meta property=\"og:image\" content=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/TS-NAP-Molecular-Biology-Imagery-RNA-and-Plasmids-Global-1-e1526867446514-1.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"1200\" \/>\n\t<meta property=\"og:image:height\" content=\"1088\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"LATB Staff\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:creator\" content=\"@ThermoFisherJP\" \/>\n<meta name=\"twitter:site\" content=\"@ThermoFisherJP\" \/>\n<meta name=\"twitter:label1\" content=\"\u57f7\u7b46\u8005\" \/>\n\t<meta name=\"twitter:data1\" content=\"LATB Staff\" \/>\n\t<meta name=\"twitter:label2\" content=\"\u63a8\u5b9a\u8aad\u307f\u53d6\u308a\u6642\u9593\" \/>\n\t<meta name=\"twitter:data2\" content=\"8\u5206\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/rna-purification2\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/rna-purification2\\\/\"},\"author\":{\"name\":\"LATB Staff\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#\\\/schema\\\/person\\\/201e6a5abb838fa34e8ff0174b015d36\"},\"headline\":\"RNA\u7cbe\u88fd\u3067\u6ce8\u610f\u3059\u3079\u304d\u30c6\u30af\u30cb\u30c3\u30af -\u305d\u306e2-\",\"datePublished\":\"2018-05-21T00:00:00+00:00\",\"dateModified\":\"2024-12-25T07:20:18+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/rna-purification2\\\/\"},\"wordCount\":135,\"commentCount\":0,\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/rna-purification2\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2019\\\/07\\\/TS-NAP-Molecular-Biology-Imagery-RNA-and-Plasmids-Global-1-e1526867446514-1.jpg\",\"keywords\":[\"\u6838\u9178\u7cbe\u88fd\"],\"articleSection\":[\"\u7d30\u80de\u57f9\u990a\u30fb\u30a4\u30e1\u30fc\u30b8\u30f3\u30b0\"],\"inLanguage\":\"ja\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/rna-purification2\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/rna-purification2\\\/\",\"url\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/rna-purification2\\\/\",\"name\":\"RNA\u7cbe\u88fd\u3067\u6ce8\u610f\u3059\u3079\u304d\u30c6\u30af\u30cb\u30c3\u30af -\u305d\u306e2- Learning at the Bench\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/rna-purification2\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/rna-purification2\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2019\\\/07\\\/TS-NAP-Molecular-Biology-Imagery-RNA-and-Plasmids-Global-1-e1526867446514-1.jpg\",\"datePublished\":\"2018-05-21T00:00:00+00:00\",\"dateModified\":\"2024-12-25T07:20:18+00:00\",\"author\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#\\\/schema\\\/person\\\/201e6a5abb838fa34e8ff0174b015d36\"},\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/rna-purification2\\\/#breadcrumb\"},\"inLanguage\":\"ja\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/rna-purification2\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"ja\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/rna-purification2\\\/#primaryimage\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2019\\\/07\\\/TS-NAP-Molecular-Biology-Imagery-RNA-and-Plasmids-Global-1-e1526867446514-1.jpg\",\"contentUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2019\\\/07\\\/TS-NAP-Molecular-Biology-Imagery-RNA-and-Plasmids-Global-1-e1526867446514-1.jpg\",\"width\":1200,\"height\":1088},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/rna-purification2\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"RNA\u7cbe\u88fd\u3067\u6ce8\u610f\u3059\u3079\u304d\u30c6\u30af\u30cb\u30c3\u30af -\u305d\u306e2-\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#website\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/\",\"name\":\"Learning at the Bench\",\"description\":\"\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"ja\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#\\\/schema\\\/person\\\/201e6a5abb838fa34e8ff0174b015d36\",\"name\":\"LATB Staff\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"ja\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/8803277856c8b753feb4217dff0f9953327452df1a615c3c88b2f9864efb2ddd?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/8803277856c8b753feb4217dff0f9953327452df1a615c3c88b2f9864efb2ddd?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/8803277856c8b753feb4217dff0f9953327452df1a615c3c88b2f9864efb2ddd?s=96&d=mm&r=g\",\"caption\":\"LATB Staff\"},\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/author\\\/latbstaff\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"RNA\u7cbe\u88fd\u3067\u6ce8\u610f\u3059\u3079\u304d\u30c6\u30af\u30cb\u30c3\u30af -\u305d\u306e2- Learning at the Bench","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/rna-purification2\/","og_locale":"ja_JP","og_type":"article","og_title":"RNA\u7cbe\u88fd\u3067\u6ce8\u610f\u3059\u3079\u304d\u30c6\u30af\u30cb\u30c3\u30af -\u305d\u306e2-","og_description":"RNA\u306e\u8abf\u6574\u30fb\u7cbe\u88fd\u306f\u3001\u6b21\u4e16\u4ee3\u30b7\u30fc\u30b1\u30f3\u30b7\u30f3\u30b0\u3001\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u306b\u3088\u308b\u767a\u73fe\u5b9a\u91cf\uff08RT-qPCR\uff09\u3001\u30ce\u30fc\u30b6\u30f3\u30d6\u30ed\u30c3\u30c8\u5206\u6790\u3084cRNA\u5408\u6210\u306a\u3069\u3001\u3055\u307e\u3056\u307e\u306a\u5b9f\u9a13\u306b\u5fc5\u8981\u3068\u306a\u308b\u57fa\u672c\u7684\u306a\u6280\u8853\u3067\u3059\u3002 \u3057\u304b\u3057\u306a\u304c\u3089RNA\u306e\u8abf\u88fd\u306e\u30b9\u30c6\u30c3\u30d7\u306f\u3001","og_url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/rna-purification2\/","og_site_name":"Learning at the Bench","article_publisher":"https:\/\/www.facebook.com\/ThermoFisherJapan","article_published_time":"2018-05-21T00:00:00+00:00","article_modified_time":"2024-12-25T07:20:18+00:00","og_image":[{"width":1200,"height":1088,"url":"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/TS-NAP-Molecular-Biology-Imagery-RNA-and-Plasmids-Global-1-e1526867446514-1.jpg","type":"image\/jpeg"}],"author":"LATB Staff","twitter_card":"summary_large_image","twitter_creator":"@ThermoFisherJP","twitter_site":"@ThermoFisherJP","twitter_misc":{"\u57f7\u7b46\u8005":"LATB Staff","\u63a8\u5b9a\u8aad\u307f\u53d6\u308a\u6642\u9593":"8\u5206"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/rna-purification2\/#article","isPartOf":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/rna-purification2\/"},"author":{"name":"LATB Staff","@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#\/schema\/person\/201e6a5abb838fa34e8ff0174b015d36"},"headline":"RNA\u7cbe\u88fd\u3067\u6ce8\u610f\u3059\u3079\u304d\u30c6\u30af\u30cb\u30c3\u30af -\u305d\u306e2-","datePublished":"2018-05-21T00:00:00+00:00","dateModified":"2024-12-25T07:20:18+00:00","mainEntityOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/rna-purification2\/"},"wordCount":135,"commentCount":0,"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/rna-purification2\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/TS-NAP-Molecular-Biology-Imagery-RNA-and-Plasmids-Global-1-e1526867446514-1.jpg","keywords":["\u6838\u9178\u7cbe\u88fd"],"articleSection":["\u7d30\u80de\u57f9\u990a\u30fb\u30a4\u30e1\u30fc\u30b8\u30f3\u30b0"],"inLanguage":"ja","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/rna-purification2\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/rna-purification2\/","url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/rna-purification2\/","name":"RNA\u7cbe\u88fd\u3067\u6ce8\u610f\u3059\u3079\u304d\u30c6\u30af\u30cb\u30c3\u30af -\u305d\u306e2- Learning at the Bench","isPartOf":{"@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/rna-purification2\/#primaryimage"},"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/rna-purification2\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/TS-NAP-Molecular-Biology-Imagery-RNA-and-Plasmids-Global-1-e1526867446514-1.jpg","datePublished":"2018-05-21T00:00:00+00:00","dateModified":"2024-12-25T07:20:18+00:00","author":{"@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#\/schema\/person\/201e6a5abb838fa34e8ff0174b015d36"},"breadcrumb":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/rna-purification2\/#breadcrumb"},"inLanguage":"ja","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/rna-purification2\/"]}]},{"@type":"ImageObject","inLanguage":"ja","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/rna-purification2\/#primaryimage","url":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/TS-NAP-Molecular-Biology-Imagery-RNA-and-Plasmids-Global-1-e1526867446514-1.jpg","contentUrl":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/TS-NAP-Molecular-Biology-Imagery-RNA-and-Plasmids-Global-1-e1526867446514-1.jpg","width":1200,"height":1088},{"@type":"BreadcrumbList","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/rna-purification2\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/"},{"@type":"ListItem","position":2,"name":"RNA\u7cbe\u88fd\u3067\u6ce8\u610f\u3059\u3079\u304d\u30c6\u30af\u30cb\u30c3\u30af -\u305d\u306e2-"}]},{"@type":"WebSite","@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#website","url":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/","name":"Learning at the Bench","description":"","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"ja"},{"@type":"Person","@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#\/schema\/person\/201e6a5abb838fa34e8ff0174b015d36","name":"LATB Staff","image":{"@type":"ImageObject","inLanguage":"ja","@id":"https:\/\/secure.gravatar.com\/avatar\/8803277856c8b753feb4217dff0f9953327452df1a615c3c88b2f9864efb2ddd?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/8803277856c8b753feb4217dff0f9953327452df1a615c3c88b2f9864efb2ddd?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/8803277856c8b753feb4217dff0f9953327452df1a615c3c88b2f9864efb2ddd?s=96&d=mm&r=g","caption":"LATB Staff"},"url":"https:\/\/admin.acceleratingscience.com\/author\/latbstaff\/"}]}},"taxonomy_info":{"category":[{"value":159,"label":"\u7d30\u80de\u57f9\u990a\u30fb\u30a4\u30e1\u30fc\u30b8\u30f3\u30b0"}],"post_tag":[{"value":77,"label":"\u6838\u9178\u7cbe\u88fd"}]},"featured_image_src_large":["https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/TS-NAP-Molecular-Biology-Imagery-RNA-and-Plasmids-Global-1-e1526867446514-1-1024x928.jpg",760,689,true],"author_info":{"display_name":"LATB Staff","author_link":"https:\/\/admin.acceleratingscience.com\/author\/latbstaff\/"},"comment_info":0,"category_info":[{"term_id":159,"name":"\u7d30\u80de\u57f9\u990a\u30fb\u30a4\u30e1\u30fc\u30b8\u30f3\u30b0","slug":"cell","term_group":0,"term_taxonomy_id":159,"taxonomy":"category","description":"","parent":0,"count":104,"filter":"raw","meta":[],"cat_ID":159,"category_count":104,"category_description":"","cat_name":"\u7d30\u80de\u57f9\u990a\u30fb\u30a4\u30e1\u30fc\u30b8\u30f3\u30b0","category_nicename":"cell","category_parent":0}],"tag_info":[{"term_id":77,"name":"\u6838\u9178\u7cbe\u88fd","slug":"nucleic-acid-purification","term_group":0,"term_taxonomy_id":77,"taxonomy":"post_tag","description":"","parent":0,"count":16,"filter":"raw","meta":[]}],"jetpack-related-posts":[{"id":25247,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/exosome-gene-expression-ts-r-25018\/","url_meta":{"origin":853,"position":0},"title":"\u3010\u7b2c4\u56de\u3011&#8221;RNA cargo&#8221;\u306e\u7cbe\u88fd\u3068\u5b9a\u91cf\u89e3\u6790\uff5emiRNA\u306e\u5b9a\u91cf\u89e3\u6790\uff5e","author":"LatB Staff","date":"2026\u5e745\u670829\u65e5","format":false,"excerpt":"\u524d\u56de\uff08\u3010\u7b2c3\u56de\u3011\u201cRNA cargo\u201d\u306e\u7cbe\u88fd\u3068\u5b9a\u91cf\u89e3\u6790\uff09\u3067\u306f\u3001\u30a8\u30af\u30bd\u30bd\u30fc\u30e0 \uff08\u30a8\u30ad\u30bd\u30bd\u30fc\u30e0\uff09 \u304b\u3089\u306e\u2026","rel":"","context":"\u5206\u6790\u30fb\u6e2c\u5b9a\u95a2\u9023","block_context":{"text":"\u5206\u6790\u30fb\u6e2c\u5b9a\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/analysis\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25018_eyecatch-1.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25018_eyecatch-1.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25018_eyecatch-1.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25018_eyecatch-1.jpg?resize=700%2C400&ssl=1 2x"},"classes":[]},{"id":25325,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/exosome-gene-expression-ts-r-25019\/","url_meta":{"origin":853,"position":1},"title":"\u3010\u7b2c5\u56de\u3011 &#8220;RNA cargo&#8221;\u306e\u7cbe\u88fd\u3068\u5b9a\u91cf\u89e3\u6790\u300d\uff5emRNA\u306e\u5b9a\u91cf\u89e3\u6790\uff5e","author":"LatB Staff","date":"2026\u5e746\u670811\u65e5","format":false,"excerpt":"\u4eca\u56de\u306f\u3001\u30a8\u30af\u30bd\u30bd\u30fc\u30e0\uff08\u30a8\u30ad\u30bd\u30bd\u30fc\u30e0\uff09\u4e2d\u306emRNA\u306e\u5b9a\u91cf\u89e3\u6790\u306b\u3064\u3044\u3066\u8aac\u660e\u3057\u307e\u3059\u3002\u7b2c3\u56de\u3067\u30a8\u30af\u30bd\u30bd\u30fc\u30e0\u304b\u2026","rel":"","context":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","block_context":{"text":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/mol-bio\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25018_eyecatch-1.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25018_eyecatch-1.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25018_eyecatch-1.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25018_eyecatch-1.jpg?resize=700%2C400&ssl=1 2x"},"classes":[]},{"id":20152,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/exosome-nucleic-acid-purification-ts-r-25017\/","url_meta":{"origin":853,"position":2},"title":"\u3010\u7b2c3\u56de\u3011\u201cRNA cargo\u201d\u306e\u7cbe\u88fd\u3068\u5b9a\u91cf\u89e3\u6790","author":"LatB Staff","date":"2026\u5e745\u670813\u65e5","format":false,"excerpt":"\u7b2c2\u56de\u3067\u306f\u3001\u57f9\u990a\u4e0a\u6e05\u3084\u3055\u307e\u3056\u307e\u306a\u4f53\u6db2\u30b5\u30f3\u30d7\u30eb\u304b\u3089\u306e\u30a8\u30af\u30bd\u30bd\u30fc\u30e0\u306e\u6fc3\u7e2e\u30fb\u56de\u53ce\u65b9\u6cd5\u306b\u3064\u3044\u3066\u7d39\u4ecb\u3057\u307e\u3057\u305f\u304c\u2026","rel":"","context":"\u305d\u306e\u4ed6","block_context":{"text":"\u305d\u306e\u4ed6","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/else\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/f17931341a23d82235760ed66ded9c41.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/f17931341a23d82235760ed66ded9c41.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/f17931341a23d82235760ed66ded9c41.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/f17931341a23d82235760ed66ded9c41.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/f17931341a23d82235760ed66ded9c41.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/f17931341a23d82235760ed66ded9c41.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":24187,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/ngs-gene-expression-csd-ts-ion-25073\/","url_meta":{"origin":853,"position":3},"title":"\u3010\u3084\u3063\u3066\u307f\u305f\u3011\u5fae\u91cf\u30fb\u5206\u89e3RNA\u306b\u3088\u308b\u767a\u73fe\u89e3\u6790\u306e\u6700\u9069\u89e3\u306f\uff1fRNA-Seq\u3068Ion AmpliSeq Transcriptome\u3092\u6bd4\u3079\u3066\u307f\u305f","author":"LatB Staff","date":"2025\u5e7411\u670828\u65e5","format":false,"excerpt":"\u6b21\u4e16\u4ee3\u30b7\u30fc\u30b1\u30f3\u30b5\u3067\u306e\u767a\u73fe\u89e3\u6790\u306b\u53d6\u308a\u7d44\u3080\u969b\u3001RNA\u30b5\u30f3\u30d7\u30eb\u304c\u300c\u5c11\u306a\u3059\u304e\u308b\u300d\u300c\u5206\u89e3\u3057\u3066\u3044\u308b\u300d\u3068\u3044\u3046\u72b6\u6cc1\u306f\u2026","rel":"","context":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","block_context":{"text":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/mol-bio\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/11\/ngs-gene-expression-csd-ts-ion-25073_eyecatch-scaled.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/11\/ngs-gene-expression-csd-ts-ion-25073_eyecatch-scaled.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/11\/ngs-gene-expression-csd-ts-ion-25073_eyecatch-scaled.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/11\/ngs-gene-expression-csd-ts-ion-25073_eyecatch-scaled.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/11\/ngs-gene-expression-csd-ts-ion-25073_eyecatch-scaled.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/11\/ngs-gene-expression-csd-ts-ion-25073_eyecatch-scaled.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":25565,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/exosome-antibody-ts-r-25068\/","url_meta":{"origin":853,"position":4},"title":"\u3010\u7b2c8\u56de\u3011\u30a8\u30af\u30bd\u30bd\u30fc\u30e0\u30b5\u30d6\u30bf\u30a4\u30d7\u306e\u5206\u753b\u6cd5 \uff1a \u30a6\u30a7\u30b9\u30bf\u30f3\u30d6\u30ed\u30c3\u30c8\uff0fqRT-PCR\uff0f\u30b7\u30fc\u30b1\u30f3\u30b9\u89e3\u6790\u306b\u9069\u3057\u305f\u5206\u753b\u65b9\u6cd5","author":"LatB Staff","date":"2026\u5e749\u670829\u65e5","format":false,"excerpt":"\u672c\u7a3f\u3067\u306f\u3001\u30a8\u30af\u30bd\u30bd\u30fc\u30e0\u819c\u4e0a\u306e\u7279\u5b9a\u306e\u30bf\u30f3\u30d1\u30af\u8cea\u3092\u6a19\u7684\u3068\u3057\u305f\u514d\u75ab\u5438\u7740\u6cd5\u306b\u57fa\u3065\u304f\u5206\u753b\u624b\u6cd5\u3092\u7d39\u4ecb\u3057\u307e\u3059\u3002\u30a8\u30af\u2026","rel":"","context":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","block_context":{"text":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/mol-bio\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25019_eyecatch.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25019_eyecatch.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25019_eyecatch.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25019_eyecatch.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25019_eyecatch.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25019_eyecatch.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":24953,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/ngs-gene-expression-csd-ts-ion-26011\/","url_meta":{"origin":853,"position":5},"title":"\u30e9\u30a4\u30d6\u30e9\u30ea\u30fc\u8abf\u88fd\u306e\u81ea\u52d5\u5316\u3067NGS\u306e\u53ef\u80fd\u6027\u3092\u5e83\u3052\u308b\u2015Ion Chef\u30b7\u30b9\u30c6\u30e0\u304c\u5909\u3048\u308b\u7814\u7a76\u5ba4\u306e\u30ef\u30fc\u30af\u30d5\u30ed\u30fc","author":"LatB Staff","date":"2026\u5e744\u670810\u65e5","format":false,"excerpt":"\u524d\u51e6\u7406\u306e\u81ea\u52d5\u5316\u304c\u3001NGS\u306e\u65b0\u3057\u3044\u6a19\u6e96\u3092\u3064\u304f\u308b\u6b21\u4e16\u4ee3\u30b7\u30fc\u30b1\u30f3\u30b7\u30f3\u30b0\uff08NGS\uff09\u304c\u65e5\u5e38\u7684\u306a\u7814\u7a76\u30c4\u30fc\u30eb\u3068\u306a\u3063\u2026","rel":"","context":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","block_context":{"text":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/mol-bio\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/02\/ngs-gene-expression-csd-ts-ion-26011_eyecatch.jpeg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/02\/ngs-gene-expression-csd-ts-ion-26011_eyecatch.jpeg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/02\/ngs-gene-expression-csd-ts-ion-26011_eyecatch.jpeg?resize=525%2C300&ssl=1 1.5x"},"classes":[]}],"jetpack_sharing_enabled":true,"amp_enabled":true,"jetpack_featured_media_url":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/TS-NAP-Molecular-Biology-Imagery-RNA-and-Plasmids-Global-1-e1526867446514-1.jpg","_links":{"self":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/posts\/853","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/users\/988"}],"replies":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/comments?post=853"}],"version-history":[{"count":0,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/posts\/853\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/media\/3628"}],"wp:attachment":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/media?parent=853"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/categories?post=853"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/tags?post=853"},{"taxonomy":"division","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/division?post=853"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}