{"id":856,"date":"2018-07-10T00:00:00","date_gmt":"2018-07-10T00:00:00","guid":{"rendered":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/ph-gradient\/"},"modified":"2023-12-28T13:57:41","modified_gmt":"2023-12-28T04:57:41","slug":"ph-gradient","status":"publish","type":"post","link":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/ph-gradient\/","title":{"rendered":"\u30a4\u30f3\u30bf\u30af\u30c8\u30bf\u30f3\u30d1\u30af\u8cea\u5206\u96e2\u306b\u5869\u30b0\u30e9\u30b8\u30a8\u30f3\u30c8\u3068pH\u30b0\u30e9\u30b8\u30a8\u30f3\u30c8\u306e\u3069\u3061\u3089\u3092\u9078\u629e\u3057\u307e\u3059\u304b\uff1f"},"content":{"rendered":"<p>\u904e\u53bb20\u5e74\u3067\u3001\u4f4e\u5206\u5b50\u533b\u85ac\u54c1\u306e\u958b\u767a\u304b\u3089\u9ad8\u5206\u5b50\u533b\u85ac\u54c1\u306e\u958b\u767a\u306b\u79fb\u884c\u304c\u9032\u3093\u3067\u3044\u307e\u3059\u3002\u73fe\u5728\u3001\u30d0\u30a4\u30aa\u533b\u85ac\u54c1\u306f\u533b\u85ac\u54c1\u5e02\u5834\u306e\u4e0a\u4f4d\u534a\u5206\u4ee5\u4e0a\u3092\u5360\u3081\u3066\u3044\u307e\u3059\u3002\u3053\u306e\u3088\u3046\u306a\u4e2d\u3001\u30d0\u30a4\u30aa\u533b\u85ac\u54c1\u306e\u958b\u767a\u304b\u3089\u54c1\u8cea\u7ba1\u7406\u306b\u304a\u3044\u3066\u3001\u30a4\u30aa\u30f3\u4ea4\u63db\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc\u3092\u5229\u7528\u3057\u305f\u30a4\u30f3\u30bf\u30af\u30c8\u30bf\u30f3\u30d1\u30af\u8cea\u306e\u5206\u96e2\u304c\u5e83\u304f\u884c\u308f\u308c\u308b\u3088\u3046\u306b\u306a\u308a\u307e\u3057\u305f\u3002\u306a\u304b\u3067\u3082\u3001<u>\u30c1\u30e3\u30fc\u30b8\u30d0\u30ea\u30a2\u30f3\u30c8\u306e\u5206\u6790\u306f\u3001\u30d0\u30a4\u30aa\u533b\u85ac\u54c1\u306e\u5b89\u5168\u6027\u3084\u52b9\u80fd\u3092\u78ba\u4fdd\u3059\u308b\u305f\u3081\u306b\u975e\u5e38\u306b\u91cd\u8981\u306a\u5206\u6790\u306e\u4e00\u3064\u3067\u3059\u3002<\/u><\/p>\n<p>\u4e00\u822c\u7684\u306b\u30c1\u30e3\u30fc\u30b8\u30d0\u30ea\u30a2\u30f3\u30c8\u306e\u5206\u6790\u306f\u3001\u30a4\u30aa\u30f3\u4ea4\u63db\u30ab\u30e9\u30e0\u3092\u4f7f\u7528\u3057\u305f\u4ee5\u4e0b\u4e8c\u3064\u306e\u79fb\u52d5\u76f8\u3092\u5229\u7528\u3057\u307e\u3059\u3002<\/p>\n<ul>\n<li>\u5869\u30b0\u30e9\u30b8\u30a8\u30f3\u30c8<\/li>\n<li>pH\u30b0\u30e9\u30b8\u30a8\u30f3\u30c8<\/li>\n<\/ul>\n<p>\u3053\u3053\u3067\u306f\u3001\u30c1\u30e3\u30fc\u30b8\u30d0\u30ea\u30a2\u30f3\u30c8\u306e\u5206\u6790\u3092\u884c\u3046\u969b\u306b\u91cd\u8981\u306a<strong>\u5869\u30b0\u30e9\u30b8\u30a8\u30f3\u30c8\u3068<\/strong><strong>pH<\/strong><strong>\u30b0\u30e9\u30b8\u30a8\u30f3\u30c8\u306e\u9055\u3044<\/strong>\u3092\u3054\u7d39\u4ecb\u3057\u307e\u3059\u3002<\/p>\n<p>&nbsp;<\/p>\n<h4><span style=\"font-size: 12pt\"><strong>\u25a0\u5869\u30b0\u30e9\u30b8\u30a8\u30f3\u30c8<\/strong><\/span><\/h4>\n<p>\u30d0\u30a4\u30aa\u533b\u85ac\u54c1\u306e\u5834\u5408\u306e\u30a4\u30f3\u30bf\u30af\u30c8\u30bf\u30f3\u30d1\u30af\u8cea\u3068\u3057\u3066\u3001\u4e00\u822c\u7684\u306b\u30e2\u30ce\u30af\u30ed\u30fc\u30ca\u30eb\u6297\u4f53\uff08mAb\uff09\u304c\u77e5\u3089\u308c\u3066\u3044\u307e\u3059\u3002\u5869\u30b0\u30e9\u30b8\u30a8\u30f3\u30c8\u3067\u306f\u3001\u3053\u306emAb\u3068\u30ca\u30c8\u30ea\u30a6\u30a4\u30aa\u30f3\uff08Na<sup>+<\/sup>\uff09\u304cIEX\uff08\u30a4\u30aa\u30f3\u4ea4\u63db\uff09\u56fa\u5b9a\u76f8\u306e\u30a4\u30aa\u30f3\u4ea4\u63db\u57fa\u3092\u596a\u3044\u5408\u3044\u307e\u3059\u3002\u5869\u6fc3\u5ea6\u304c\u9ad8\u304f\u306a\u308b\u306b\u3064\u308c\u3001\u30a4\u30aa\u30f3\u4ea4\u63db\u90e8\u4f4d\u306e\u4e89\u596a\u3067\u30ca\u30c8\u30ea\u30a6\u30e0\u30a4\u30aa\u30f3\u304cmAb\u306b\u52dd\u3063\u3066\u3044\u304f\u305f\u3081\u3001mAb\u306f\u6eb6\u51fa\u3057\u59cb\u3081\u307e\u3059\u3002\u5869\u30b0\u30e9\u30b8\u30a7\u30f3\u30c8\u3067\u306f\u3001\u3053\u306emAb\u306f\u30ab\u30e9\u30e0\u5168\u4f53\u306e\u9023\u7d9a\u7684\u306a\u76f8\u4e92\u4f5c\u7528\u3092\u901a\u3057\u3066\u6eb6\u51fa\u3055\u308c\u308b\u305f\u3081\u3001\u30ab\u30e9\u30e0\u306e\u9577\u3055\u304c\u9577\u3044\u307b\u3069\u5206\u96e2\u304c\u826f\u597d\u306b\u306a\u308a\u307e\u3059\u3002<\/p>\n<p>&nbsp;<\/p>\n<h4><span style=\"font-size: 12pt\"><strong>\u25a0pH\u30b0\u30e9\u30b8\u30a8\u30f3\u30c8<\/strong><\/span><\/h4>\n<p>pH\u30b0\u30e9\u30b8\u30a8\u30f3\u30c8\u3092\u4f7f\u7528\u3059\u308b\u5834\u5408\u3001mAb\u306f\u56fa\u5b9a\u76f8\u306e\u30a4\u30aa\u30f3\u4ea4\u63db\u57fa\u306b\u7d50\u5408\u3057\u307e\u3059\u3002\u305d\u306e\u5f8c\u3001pH\u3092\u6b21\u7b2c\u306b\u4e0a\u6607\u3055\u305b\u3066\u3044\u304d\u307e\u3059\u3002mAb\u306e\u96fb\u8377\u304c\u7b49\u96fb\u70b9\uff08pI\uff09\u306b\u304a\u3044\u3066\u5168\u304f\u30c1\u30e3\u30fc\u30b8\u3092\u3082\u305f\u306a\u3044\u72b6\u614b\uff08\u30cb\u30e5\u30fc\u30c8\u30e9\u30eb\uff09\u306b\u306a\u308b\u3068\u3001mAb\u306f\u904a\u96e2\u3057\u3001\u6eb6\u51fa\u3057\u307e\u3059\u3002<strong>\u5869\u30b0\u30e9\u30b8\u30a8\u30f3\u30c8\u3068\u306f\u7570\u306a\u308a\u3001\u3053\u308c\u4ee5\u964d\u306f\u56fa\u5b9a\u76f8\u3068\u306e\u76f8\u4e92\u4f5c\u7528\u304c\u767a\u751f\u3057\u306a\u3044\u305f\u3081\u3001\u30ab\u30e9\u30e0\u306e\u9577\u3055\u306f\u5206\u96e2\u306b\u307b\u3068\u3093\u3069\u5f71\u97ff\u3057\u307e\u305b\u3093\u3002<\/strong><\/p>\n<p>&nbsp;<\/p>\n<h2><strong>\u5869\u30b0\u30e9\u30b8\u30a8\u30f3\u30c8\u3001\u305d\u308c\u3068\u3082<\/strong><strong>pH<\/strong><strong>\u30b0\u30e9\u30b8\u30a8\u30f3\u30c8\uff1f<\/strong><\/h2>\n<p><strong>\u00a0<\/strong><\/p>\n<p>\u5869\u30b0\u30e9\u30b8\u30a8\u30f3\u30c8\u306f\u4e00\u822c\u7684\u3067\u3001\u591a\u304f\u306e\u4eba\u304c\u4f7f\u3044\u6163\u308c\u3066\u3044\u3066\u3001\u7279\u306b\u554f\u984c\u306a\u304f\u4f7f\u308f\u308c\u3066\u3044\u307e\u3059\u3002\u3057\u304b\u3057\u3001\u4eca\u306e\u3084\u308a\u65b9\u306b\u56fa\u57f7\u3059\u308b\u3053\u3068\u304c\u6700\u826f\u306a\u306e\u3067\u3057\u3087\u3046\u304b\uff1f<\/p>\n<p>\u305d\u3053\u3067\u3001\u5869\u30b0\u30e9\u30b8\u30a8\u30f3\u30c8\u3068pH\u30b0\u30e9\u30b8\u30a8\u30f3\u30c8\u306e\u8003\u3048\u3089\u308c\u308b\u6b20\u70b9\u3092\u307e\u3068\u3081\u3066\u307f\u307e\u3057\u305f\uff08\u4e0b\u8a18\u53c2\u7167\uff09\u3002<\/p>\n<p>&nbsp;<\/p>\n<h4>\u25bc\u5869\u30b0\u30e9\u30b8\u30a8\u30f3\u30c8\u306e\u6b20\u70b9<\/h4>\n<ul>\n<li>\u5206\u6790\u6642\u9593\u304c\u9577\u304f\u306a\u308b\uff06\u30d0\u30c3\u30af\u30d7\u30ec\u30c3\u30b7\u30e3\u30fc\uff08\u80cc\u5727\uff09\u304c\u9ad8\u307e\u308b\n<ul>\n<li>\u30ab\u30e9\u30e0\u306e\u4ed5\u69d8\u3067\u5b9a\u3081\u3066\u3044\u308b\u5727\u529b\u7bc4\u56f2\u3092\u8d85\u3048\u3001\u30ab\u30e9\u30e0\u306e\u5145\u586b\u5264\u3092\u7834\u58ca\u3059\u308b\u304a\u305d\u308c\u304c\u3042\u308b\u3002<\/li>\n<\/ul>\n<\/li>\n<li>\u6700\u9069\u306a\u5206\u96e2\u6761\u4ef6\u3092\u691c\u8a0e\u3059\u308b\u305f\u3081\u306e\u624b\u9593\u3068\u6642\u9593\u304c\u304b\u304b\u308b<\/li>\n<li>\u9ad8\u5869\u6fc3\u5ea6\u30d0\u30c3\u30d5\u30a1\u30fc\u4e2d\u306b\u30b5\u30f3\u30d7\u30eb\u304c\u3042\u308b\u5834\u5408\u3001\u30ab\u30e9\u30e0\u30d8\u30c3\u30c9\u3067\u6eb6\u96e2\u6db2\u3068\u306e\u30d0\u30c3\u30d5\u30a1\u30fc\u4ea4\u63db\u304c\u8d77\u3053\u308b\u304a\u305d\u308c\u304c\u3042\u308b\n<ul>\n<li>\u79fb\u52d5\u76f8\u3068\u30b5\u30f3\u30d7\u30eb\u306e\u5869\u6fc3\u5ea6\u304c\u5927\u304d\u304f\u7570\u306a\u308b\u305f\u3081\u3001\u5206\u96e2\u304c\u4f4e\u4e0b\u3059\u308b\u3002<\/li>\n<\/ul>\n<\/li>\n<\/ul>\n<p>&nbsp;<\/p>\n<h4>\u25bcpH\u30b0\u30e9\u30b8\u30a8\u30f3\u30c8\u306e\u6b20\u70b9<\/h4>\n<ul>\n<li>\u518d\u73fe\u6027\u306e\u3042\u308b\u76f4\u7dda\u306epH\u30b0\u30e9\u30b8\u30a8\u30f3\u30c8\u3092\u751f\u6210\u3059\u308b\u3053\u3068\u304c\u96e3\u3057\u3044\u3002\n<ul>\n<li>\u30d7\u30ed\u30b0\u30e9\u30e0\u3055\u308c\u305f\u30b0\u30e9\u30b8\u30a8\u30f3\u30c8\u306epH\u3092\u5b9f\u6e2c\u3059\u308b\u3068\u3001\u30b0\u30e9\u30b8\u30a8\u30f3\u30c8\u304c\u66f2\u7dda\u306b\u306a\u3063\u305f\u308a\u3001\u518d\u73fe\u6027\u304c\u60aa\u304f\u306a\u3063\u305f\u308a\u3059\u308b\u5834\u5408\u304c\u3042\u308b\u3002\u305d\u306e\u305f\u3081\u3001\u30b0\u30e9\u30b8\u30a8\u30f3\u30c8\u3092\u5f62\u6210\u3059\u308b\u305f\u3081\u306bpH\u30d0\u30c3\u30d5\u30a1\u30fc\u539f\u6db2\u3092\u8abf\u88fd\u3059\u308b\u3053\u3068\u306f\u6c7a\u3057\u3066\u7c21\u5358\u3067\u306f\u306a\u3044\u3002<\/li>\n<\/ul>\n<\/li>\n<\/ul>\n<p>&nbsp;<\/p>\n<p>\u307e\u305f\u3001<span style=\"font-size: 18pt\"><a href=\"https:\/\/www.youtube.com\/watch?v=_zsYUjHqiQw\">\u52d5\u753b\u3067\u5206\u304b\u308bpH\u30b0\u30e9\u30b8\u30a8\u30f3\u30c8\u306b\u3088\u308b\u30c1\u30e3\u30fc\u30b8\u30d0\u30ea\u30a2\u30f3\u30c8\u5206\u6790<\/a><\/span>\u3082\u5408\u308f\u305b\u3066\u3054\u53c2\u7167\u304f\u3060\u3055\u3044\uff01<\/p>\n<h2>\u307e\u3068\u3081<\/h2>\n<p>mAb\u306e\u30c1\u30e3\u30fc\u30b8\u30d0\u30ea\u30a2\u30f3\u30c8\u5206\u6790\u306b\u304a\u3051\u308b\u30a4\u30aa\u30f3\u4ea4\u63db\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc\u306f\u3001\u5869\u30b0\u30e9\u30b8\u30a8\u30f3\u30c8\u307e\u305f\u306fpH\u30b0\u30e9\u30b8\u30a8\u30f3\u30c8\u3067\u884c\u3046\u3053\u3068\u304c\u3067\u304d\u307e\u3059\u3002\u3044\u305a\u308c\u306e\u30a2\u30d7\u30ed\u30fc\u30c1\u306b\u3082\u5229\u70b9\u3068\u6b20\u70b9\u304c\u3042\u308a\u307e\u3059\u304c\u3001<strong>\u7279\u306b\u8fd1\u5e74\u306e<\/strong><strong>pH<\/strong><strong>\u30b0\u30e9\u30b8\u30a8\u30f3\u30c8\u30d0\u30c3\u30d5\u30a1\u30fc\u306e\u6539\u5584\u306b\u3088\u308a\u3001\u30d0\u30c3\u30d5\u30a1\u30fc\u8abf\u88fd\u306e\u554f\u984c\u306f\u307b\u3068\u3093\u3069\u89e3\u6c7a\u3057\u3001\u9ad8\u5206\u96e2\u304b\u3064\u9ad8\u3044\u518d\u73fe\u6027\u3067\u8fc5\u901f\u306b\u30e1\u30bd\u30c3\u30c9\u958b\u767a\u3068\u5206\u96e2\u3092\u884c\u306a\u3048\u308b\u3088\u3046\u306b\u306a\u308a\u307e\u3057\u305f\u3002<\/strong>\u305d\u306e\u305f\u3081pH\u30b0\u30e9\u30b8\u30a8\u30f3\u30c8\u306b\u3088\u308b\u30a2\u30d7\u30ed\u30fc\u30c1\u306f\u5927\u5909\u9b45\u529b\u7684\u306a\u3082\u306e\u3068\u306a\u3063\u3066\u3044\u307e\u3059\u3002<\/p>\n<p>&nbsp;<\/p>\n<p>\u4ee5\u4e0b\u306b\u95a2\u9023\u60c5\u5831\u3092\u63b2\u8f09\u3057\u3066\u304a\u308a\u307e\u3059\u306e\u3067\u3001\u305c\u3072\u3054\u89a7\u304f\u3060\u3055\u3044\u3002<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<h2>\u95a2\u9023\u60c5\u5831<\/h2>\n<p>\u2714<a href=\"http:\/\/www.thermofisher.com\/jp\/ja\/home\/industrial\/pharma-biopharma\/biopharmaceutical-analytical-testing\/intact-protein-analysis-workflows.html?CID=Social\">\u30a4\u30f3\u30bf\u30af\u30c8\u30bf\u30f3\u30d1\u30af\u8cea\u5206\u6790\u30ef\u30fc\u30af\u30d5\u30ed\u30fc<\/a><\/p>\n<p>\u2714<a href=\"http:\/\/tools.thermofisher.com\/content\/sfs\/brochures\/AN-21684-LC-NISTmAb-Charge-Variant-Analysis-AN21684-EN.pdf?CID=Social\">NIBRT\u30a2\u30d7\u30ea\u30b1\u30fc\u30b7\u30e7\u30f3\u30ce\u30fc\u30c8<\/a>\uff08\u82f1\u8a9e\uff09\uff1a\u30c1\u30e3\u30fc\u30b8\u30d0\u30ea\u30a2\u30f3\u30c8\u5206\u6790\u306e\u305f\u3081\u306eThermo Scientific\u2122 CX-1 pH\u30b0\u30e9\u30b8\u30a8\u30f3\u30c8\u30d0\u30c3\u30d5\u30a1\u30fc\u306e\u8a73\u7d30\u60c5\u5831\u3092\u63b2\u8f09\u3002<\/p>\n<p>\u2714<a href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/industrial\/pharma-biopharma\/biopharmaceutical-analytical-testing\/intact-protein-analysis-workflows\/charge-variant-analysis.html?CID=Social\">\u30c1\u30e3\u30fc\u30b8\u30d0\u30ea\u30a2\u30f3\u30c8\u5206\u6790\u306b\u3064\u3044\u3066<\/a><\/p>\n<p>\u2714<a href=\"http:\/\/apps.thermoscientific.com\/media\/cmd\/Biopharma_Compendium\/#6?CID=Social\">\u30d0\u30a4\u30aa\u533b\u85ac\u54c1\u7279\u6027\u89e3\u6790\u306b\u95a2\u3059\u308b\u60c5\u5831\uff1a\u300eBiopharmaceutical Characterization Application Compendium\u300f\uff08\u30d0\u30a4\u30aa\u533b\u85ac\u54c1\u7279\u6027\u89e3\u6790\u30a2\u30d7\u30ea\u30b1\u30fc\u30b7\u30e7\u30f3\u96c6\u3001\u82f1\u8a9e\uff09<\/a><\/p>\n<p>&nbsp;<\/p>\n<p>\u7814\u7a76\u7528\u306b\u306e\u307f\u4f7f\u7528\u3067\u304d\u307e\u3059\u3002\u8a3a\u65ad\u7528\u306b\u306f\u4f7f\u7528\u3044\u305f\u3060\u3051\u307e\u305b\u3093\u3002<\/p>\n","protected":false},"excerpt":{"rendered":"<p>\u904e\u53bb20\u5e74\u3067\u3001\u4f4e\u5206\u5b50\u533b\u85ac\u54c1\u306e\u958b\u767a\u304b\u3089\u9ad8\u5206\u5b50\u533b\u85ac\u54c1\u306e\u958b\u767a\u306b\u79fb\u884c\u304c\u9032\u3093\u3067\u3044\u307e\u3059\u3002\u73fe\u5728\u3001\u30d0\u30a4\u30aa\u533b\u85ac\u54c1\u306f\u533b\u85ac\u54c1\u5e02\u5834\u306e\u4e0a\u4f4d\u534a\u5206\u4ee5\u4e0a\u3092\u5360\u3081\u3066\u3044\u307e\u3059\u3002\u3053\u306e\u3088\u3046\u306a\u4e2d\u3001\u30d0\u30a4\u30aa\u533b\u85ac\u54c1\u306e\u958b\u767a\u304b\u3089\u54c1\u8cea\u7ba1\u7406\u306b\u304a\u3044\u3066\u3001\u30a4\u30aa\u30f3\u4ea4\u63db\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc\u3092<\/p>\n","protected":false},"author":988,"featured_media":3631,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_monsterinsights_skip_tracking":false,"_genesis_hide_title":false,"_genesis_hide_breadcrumbs":false,"_genesis_hide_singular_image":false,"_genesis_hide_footer_widgets":false,"_genesis_custom_body_class":"","_genesis_custom_post_class":"","_genesis_layout":"","_jetpack_newsletter_access":"","_jetpack_dont_email_post_to_subs":false,"_jetpack_newsletter_tier_id":0,"_jetpack_memberships_contains_paywalled_content":false,"_jetpack_hide_featured_image":false,"_jetpack_featured_image_duplicate_dismissed":0,"_jetpack_feature_clip_id":0,"_jetpack_memberships_contains_paid_content":false,"footnotes":"","jetpack_post_was_ever_published":false},"categories":[157],"tags":[52],"division":[],"class_list":["post-856","post","type-post","status-publish","format-standard","has-post-thumbnail","category-analysis","tag-ion-chromatography","entry"],"_selected_authors":"","_selected_reviewers":"","acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v28.9 (Yoast SEO v28.9) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>\u30a4\u30f3\u30bf\u30af\u30c8\u30bf\u30f3\u30d1\u30af\u8cea\u5206\u96e2\u306b\u5869\u30b0\u30e9\u30b8\u30a8\u30f3\u30c8\u3068pH\u30b0\u30e9\u30b8\u30a8\u30f3\u30c8\u306e\u3069\u3061\u3089\u3092\u9078\u629e\u3057\u307e\u3059\u304b\uff1f - Learning at the Bench<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/ph-gradient\/\" \/>\n<meta property=\"og:locale\" content=\"ja_JP\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"\u30a4\u30f3\u30bf\u30af\u30c8\u30bf\u30f3\u30d1\u30af\u8cea\u5206\u96e2\u306b\u5869\u30b0\u30e9\u30b8\u30a8\u30f3\u30c8\u3068pH\u30b0\u30e9\u30b8\u30a8\u30f3\u30c8\u306e\u3069\u3061\u3089\u3092\u9078\u629e\u3057\u307e\u3059\u304b\uff1f\" \/>\n<meta property=\"og:description\" content=\"\u904e\u53bb20\u5e74\u3067\u3001\u4f4e\u5206\u5b50\u533b\u85ac\u54c1\u306e\u958b\u767a\u304b\u3089\u9ad8\u5206\u5b50\u533b\u85ac\u54c1\u306e\u958b\u767a\u306b\u79fb\u884c\u304c\u9032\u3093\u3067\u3044\u307e\u3059\u3002\u73fe\u5728\u3001\u30d0\u30a4\u30aa\u533b\u85ac\u54c1\u306f\u533b\u85ac\u54c1\u5e02\u5834\u306e\u4e0a\u4f4d\u534a\u5206\u4ee5\u4e0a\u3092\u5360\u3081\u3066\u3044\u307e\u3059\u3002\u3053\u306e\u3088\u3046\u306a\u4e2d\u3001\u30d0\u30a4\u30aa\u533b\u85ac\u54c1\u306e\u958b\u767a\u304b\u3089\u54c1\u8cea\u7ba1\u7406\u306b\u304a\u3044\u3066\u3001\u30a4\u30aa\u30f3\u4ea4\u63db\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc\u3092\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/ph-gradient\/\" \/>\n<meta property=\"og:site_name\" content=\"Learning at the Bench\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/ThermoFisherJapan\" \/>\n<meta property=\"article:published_time\" content=\"2018-07-10T00:00:00+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2023-12-28T04:57:41+00:00\" \/>\n<meta property=\"og:image\" content=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/shutterstock_389524267b-c-BLOG.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"1200\" \/>\n\t<meta property=\"og:image:height\" content=\"630\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"LATB Staff\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:creator\" content=\"@ThermoFisherJP\" \/>\n<meta name=\"twitter:site\" content=\"@ThermoFisherJP\" \/>\n<meta name=\"twitter:label1\" content=\"\u57f7\u7b46\u8005\" \/>\n\t<meta name=\"twitter:data1\" content=\"LATB Staff\" \/>\n\t<meta name=\"twitter:label2\" content=\"\u63a8\u5b9a\u8aad\u307f\u53d6\u308a\u6642\u9593\" \/>\n\t<meta name=\"twitter:data2\" content=\"5\u5206\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/ph-gradient\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/ph-gradient\\\/\"},\"author\":{\"name\":\"LATB Staff\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#\\\/schema\\\/person\\\/201e6a5abb838fa34e8ff0174b015d36\"},\"headline\":\"\u30a4\u30f3\u30bf\u30af\u30c8\u30bf\u30f3\u30d1\u30af\u8cea\u5206\u96e2\u306b\u5869\u30b0\u30e9\u30b8\u30a8\u30f3\u30c8\u3068pH\u30b0\u30e9\u30b8\u30a8\u30f3\u30c8\u306e\u3069\u3061\u3089\u3092\u9078\u629e\u3057\u307e\u3059\u304b\uff1f\",\"datePublished\":\"2018-07-10T00:00:00+00:00\",\"dateModified\":\"2023-12-28T04:57:41+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/ph-gradient\\\/\"},\"wordCount\":47,\"commentCount\":0,\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/ph-gradient\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2019\\\/07\\\/shutterstock_389524267b-c-BLOG.jpg\",\"keywords\":[\"\u30a4\u30aa\u30f3\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc\"],\"articleSection\":[\"\u5206\u6790\u30fb\u6e2c\u5b9a\u95a2\u9023\"],\"inLanguage\":\"ja\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/ph-gradient\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/ph-gradient\\\/\",\"url\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/ph-gradient\\\/\",\"name\":\"\u30a4\u30f3\u30bf\u30af\u30c8\u30bf\u30f3\u30d1\u30af\u8cea\u5206\u96e2\u306b\u5869\u30b0\u30e9\u30b8\u30a8\u30f3\u30c8\u3068pH\u30b0\u30e9\u30b8\u30a8\u30f3\u30c8\u306e\u3069\u3061\u3089\u3092\u9078\u629e\u3057\u307e\u3059\u304b\uff1f - Learning at the Bench\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/ph-gradient\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/ph-gradient\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2019\\\/07\\\/shutterstock_389524267b-c-BLOG.jpg\",\"datePublished\":\"2018-07-10T00:00:00+00:00\",\"dateModified\":\"2023-12-28T04:57:41+00:00\",\"author\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#\\\/schema\\\/person\\\/201e6a5abb838fa34e8ff0174b015d36\"},\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/ph-gradient\\\/#breadcrumb\"},\"inLanguage\":\"ja\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/ph-gradient\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"ja\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/ph-gradient\\\/#primaryimage\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2019\\\/07\\\/shutterstock_389524267b-c-BLOG.jpg\",\"contentUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2019\\\/07\\\/shutterstock_389524267b-c-BLOG.jpg\",\"width\":1200,\"height\":630},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/ph-gradient\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"\u30a4\u30f3\u30bf\u30af\u30c8\u30bf\u30f3\u30d1\u30af\u8cea\u5206\u96e2\u306b\u5869\u30b0\u30e9\u30b8\u30a8\u30f3\u30c8\u3068pH\u30b0\u30e9\u30b8\u30a8\u30f3\u30c8\u306e\u3069\u3061\u3089\u3092\u9078\u629e\u3057\u307e\u3059\u304b\uff1f\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#website\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/\",\"name\":\"Learning at the Bench\",\"description\":\"\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"ja\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#\\\/schema\\\/person\\\/201e6a5abb838fa34e8ff0174b015d36\",\"name\":\"LATB Staff\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"ja\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/8803277856c8b753feb4217dff0f9953327452df1a615c3c88b2f9864efb2ddd?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/8803277856c8b753feb4217dff0f9953327452df1a615c3c88b2f9864efb2ddd?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/8803277856c8b753feb4217dff0f9953327452df1a615c3c88b2f9864efb2ddd?s=96&d=mm&r=g\",\"caption\":\"LATB Staff\"},\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/author\\\/latbstaff\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"\u30a4\u30f3\u30bf\u30af\u30c8\u30bf\u30f3\u30d1\u30af\u8cea\u5206\u96e2\u306b\u5869\u30b0\u30e9\u30b8\u30a8\u30f3\u30c8\u3068pH\u30b0\u30e9\u30b8\u30a8\u30f3\u30c8\u306e\u3069\u3061\u3089\u3092\u9078\u629e\u3057\u307e\u3059\u304b\uff1f - Learning at the Bench","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/ph-gradient\/","og_locale":"ja_JP","og_type":"article","og_title":"\u30a4\u30f3\u30bf\u30af\u30c8\u30bf\u30f3\u30d1\u30af\u8cea\u5206\u96e2\u306b\u5869\u30b0\u30e9\u30b8\u30a8\u30f3\u30c8\u3068pH\u30b0\u30e9\u30b8\u30a8\u30f3\u30c8\u306e\u3069\u3061\u3089\u3092\u9078\u629e\u3057\u307e\u3059\u304b\uff1f","og_description":"\u904e\u53bb20\u5e74\u3067\u3001\u4f4e\u5206\u5b50\u533b\u85ac\u54c1\u306e\u958b\u767a\u304b\u3089\u9ad8\u5206\u5b50\u533b\u85ac\u54c1\u306e\u958b\u767a\u306b\u79fb\u884c\u304c\u9032\u3093\u3067\u3044\u307e\u3059\u3002\u73fe\u5728\u3001\u30d0\u30a4\u30aa\u533b\u85ac\u54c1\u306f\u533b\u85ac\u54c1\u5e02\u5834\u306e\u4e0a\u4f4d\u534a\u5206\u4ee5\u4e0a\u3092\u5360\u3081\u3066\u3044\u307e\u3059\u3002\u3053\u306e\u3088\u3046\u306a\u4e2d\u3001\u30d0\u30a4\u30aa\u533b\u85ac\u54c1\u306e\u958b\u767a\u304b\u3089\u54c1\u8cea\u7ba1\u7406\u306b\u304a\u3044\u3066\u3001\u30a4\u30aa\u30f3\u4ea4\u63db\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc\u3092","og_url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/ph-gradient\/","og_site_name":"Learning at the Bench","article_publisher":"https:\/\/www.facebook.com\/ThermoFisherJapan","article_published_time":"2018-07-10T00:00:00+00:00","article_modified_time":"2023-12-28T04:57:41+00:00","og_image":[{"width":1200,"height":630,"url":"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/shutterstock_389524267b-c-BLOG.jpg","type":"image\/jpeg"}],"author":"LATB Staff","twitter_card":"summary_large_image","twitter_creator":"@ThermoFisherJP","twitter_site":"@ThermoFisherJP","twitter_misc":{"\u57f7\u7b46\u8005":"LATB Staff","\u63a8\u5b9a\u8aad\u307f\u53d6\u308a\u6642\u9593":"5\u5206"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/ph-gradient\/#article","isPartOf":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/ph-gradient\/"},"author":{"name":"LATB Staff","@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#\/schema\/person\/201e6a5abb838fa34e8ff0174b015d36"},"headline":"\u30a4\u30f3\u30bf\u30af\u30c8\u30bf\u30f3\u30d1\u30af\u8cea\u5206\u96e2\u306b\u5869\u30b0\u30e9\u30b8\u30a8\u30f3\u30c8\u3068pH\u30b0\u30e9\u30b8\u30a8\u30f3\u30c8\u306e\u3069\u3061\u3089\u3092\u9078\u629e\u3057\u307e\u3059\u304b\uff1f","datePublished":"2018-07-10T00:00:00+00:00","dateModified":"2023-12-28T04:57:41+00:00","mainEntityOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/ph-gradient\/"},"wordCount":47,"commentCount":0,"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/ph-gradient\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/shutterstock_389524267b-c-BLOG.jpg","keywords":["\u30a4\u30aa\u30f3\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc"],"articleSection":["\u5206\u6790\u30fb\u6e2c\u5b9a\u95a2\u9023"],"inLanguage":"ja","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/ph-gradient\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/ph-gradient\/","url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/ph-gradient\/","name":"\u30a4\u30f3\u30bf\u30af\u30c8\u30bf\u30f3\u30d1\u30af\u8cea\u5206\u96e2\u306b\u5869\u30b0\u30e9\u30b8\u30a8\u30f3\u30c8\u3068pH\u30b0\u30e9\u30b8\u30a8\u30f3\u30c8\u306e\u3069\u3061\u3089\u3092\u9078\u629e\u3057\u307e\u3059\u304b\uff1f - Learning at the Bench","isPartOf":{"@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/ph-gradient\/#primaryimage"},"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/ph-gradient\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/shutterstock_389524267b-c-BLOG.jpg","datePublished":"2018-07-10T00:00:00+00:00","dateModified":"2023-12-28T04:57:41+00:00","author":{"@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#\/schema\/person\/201e6a5abb838fa34e8ff0174b015d36"},"breadcrumb":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/ph-gradient\/#breadcrumb"},"inLanguage":"ja","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/ph-gradient\/"]}]},{"@type":"ImageObject","inLanguage":"ja","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/ph-gradient\/#primaryimage","url":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/shutterstock_389524267b-c-BLOG.jpg","contentUrl":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/shutterstock_389524267b-c-BLOG.jpg","width":1200,"height":630},{"@type":"BreadcrumbList","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/ph-gradient\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/"},{"@type":"ListItem","position":2,"name":"\u30a4\u30f3\u30bf\u30af\u30c8\u30bf\u30f3\u30d1\u30af\u8cea\u5206\u96e2\u306b\u5869\u30b0\u30e9\u30b8\u30a8\u30f3\u30c8\u3068pH\u30b0\u30e9\u30b8\u30a8\u30f3\u30c8\u306e\u3069\u3061\u3089\u3092\u9078\u629e\u3057\u307e\u3059\u304b\uff1f"}]},{"@type":"WebSite","@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#website","url":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/","name":"Learning at the Bench","description":"","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"ja"},{"@type":"Person","@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#\/schema\/person\/201e6a5abb838fa34e8ff0174b015d36","name":"LATB Staff","image":{"@type":"ImageObject","inLanguage":"ja","@id":"https:\/\/secure.gravatar.com\/avatar\/8803277856c8b753feb4217dff0f9953327452df1a615c3c88b2f9864efb2ddd?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/8803277856c8b753feb4217dff0f9953327452df1a615c3c88b2f9864efb2ddd?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/8803277856c8b753feb4217dff0f9953327452df1a615c3c88b2f9864efb2ddd?s=96&d=mm&r=g","caption":"LATB Staff"},"url":"https:\/\/admin.acceleratingscience.com\/author\/latbstaff\/"}]}},"taxonomy_info":{"category":[{"value":157,"label":"\u5206\u6790\u30fb\u6e2c\u5b9a\u95a2\u9023"}],"post_tag":[{"value":52,"label":"\u30a4\u30aa\u30f3\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc"}]},"featured_image_src_large":["https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/shutterstock_389524267b-c-BLOG-1024x538.jpg",760,399,true],"author_info":{"display_name":"LATB Staff","author_link":"https:\/\/admin.acceleratingscience.com\/author\/latbstaff\/"},"comment_info":0,"category_info":[{"term_id":157,"name":"\u5206\u6790\u30fb\u6e2c\u5b9a\u95a2\u9023","slug":"analysis","term_group":0,"term_taxonomy_id":157,"taxonomy":"category","description":"","parent":0,"count":107,"filter":"raw","meta":[],"cat_ID":157,"category_count":107,"category_description":"","cat_name":"\u5206\u6790\u30fb\u6e2c\u5b9a\u95a2\u9023","category_nicename":"analysis","category_parent":0}],"tag_info":[{"term_id":52,"name":"\u30a4\u30aa\u30f3\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc","slug":"ion-chromatography","term_group":0,"term_taxonomy_id":52,"taxonomy":"post_tag","description":"","parent":0,"count":12,"filter":"raw","meta":[]}],"jetpack-related-posts":[{"id":25362,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/battery-development-ion-chromatography-csm-26020\/","url_meta":{"origin":856,"position":0},"title":"IC-MS\/MS\u3092\u7528\u3044\u305f\u30ea\u30c1\u30a6\u30e0\u30a4\u30aa\u30f3\u96fb\u6c60\u8ca0\u6975\u306e\u52a3\u5316\u89e3\u6790","author":"LatB Staff","date":"2026\u5e746\u670826\u65e5","format":false,"excerpt":"\u539f\u6587\uff08\u82f1\u8a9e\uff09\uff1aExploring Lithium-Ion Battery Anode Degrada\u2026","rel":"","context":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","block_context":{"text":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/mol-bio\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/06\/battery-development-ion-chromatography-csm-26020_eyecatch.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/06\/battery-development-ion-chromatography-csm-26020_eyecatch.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/06\/battery-development-ion-chromatography-csm-26020_eyecatch.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/06\/battery-development-ion-chromatography-csm-26020_eyecatch.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/06\/battery-development-ion-chromatography-csm-26020_eyecatch.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/06\/battery-development-ion-chromatography-csm-26020_eyecatch.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":25170,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/antibody-purification-vaccine-bpg-26018\/","url_meta":{"origin":856,"position":1},"title":"\u3010\u7c21\u5358\u89e3\u8aac\uff01\u3011\u30d0\u30a4\u30b9\u30da\u30b7\u30d5\u30a3\u30c3\u30af\u6297\u4f53\u7cbe\u88fd\u306e\u57fa\u790e\u3068\u30a2\u30d5\u30a3\u30cb\u30c6\u30a3\u6a39\u8102\u9078\u629e","author":"LatB Staff","date":"2026\u5e745\u670819\u65e5","format":false,"excerpt":"\u5c0e\u5165 \u30d0\u30a4\u30b9\u30da\u30b7\u30d5\u30a3\u30c3\u30af\u6297\u4f53\uff08bispecific antibody\u3001\u4ee5\u4e0bBsAb\uff09\u306f\u30012\u3064\u306e\u7570\u306a\u308b\u2026","rel":"","context":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","block_context":{"text":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/mol-bio\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/04\/antibody-purification-vaccine-bpg-26018_eyecatch.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/04\/antibody-purification-vaccine-bpg-26018_eyecatch.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/04\/antibody-purification-vaccine-bpg-26018_eyecatch.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/04\/antibody-purification-vaccine-bpg-26018_eyecatch.jpg?resize=700%2C400&ssl=1 2x"},"classes":[]},{"id":25090,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/battery-development-elemental-analysis-csm-26016\/","url_meta":{"origin":856,"position":2},"title":"\u30ea\u30c1\u30a6\u30e0\u30a4\u30aa\u30f3\u96fb\u6c60\u88fd\u9020\uff1a\u4f7f\u7528\u3055\u308c\u308b\u5316\u5b66\u5206\u6790\u6280\u8853","author":"LatB Staff","date":"2026\u5e744\u670820\u65e5","format":false,"excerpt":"\u9ad8\u6027\u80fd\u96fb\u6c60\u306b\u5bfe\u3059\u308b\u9700\u8981\u306e\u6025\u5897\u306f\u3001\u751f\u7523\u306e\u3042\u3089\u3086\u308b\u6bb5\u968e\u306b\u304a\u3051\u308b\u5927\u898f\u6a21\u306a\u6295\u8cc7\u3092\u4fc3\u3057\u3066\u3044\u307e\u3059\u3002\u96fb\u6c60\u7814\u7a76\u304a\u3088\u3073\u2026","rel":"","context":"\u5206\u6790\u30fb\u6e2c\u5b9a\u95a2\u9023","block_context":{"text":"\u5206\u6790\u30fb\u6e2c\u5b9a\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/analysis\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/04\/battery-development-elemental-analysis-csm-26016_eyecatch.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/04\/battery-development-elemental-analysis-csm-26016_eyecatch.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/04\/battery-development-elemental-analysis-csm-26016_eyecatch.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/04\/battery-development-elemental-analysis-csm-26016_eyecatch.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/04\/battery-development-elemental-analysis-csm-26016_eyecatch.jpg?resize=1050%2C600&ssl=1 3x"},"classes":[]},{"id":24695,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/environmental-analysis-laboratory-lpd-26008\/","url_meta":{"origin":856,"position":3},"title":"Orion Pro Star pH\uff0fISE\u30e1\u30fc\u30bf\u30fc\u3067\u5b9f\u73fe\u3059\u308b\u30a2\u30f3\u30e2\u30cb\u30a2\u30a4\u30aa\u30f3\u306e\u8fc5\u901f\u30fb\u9ad8\u7cbe\u5ea6\u6e2c\u5b9a\u5165\u9580","author":"LatB Staff","date":"2026\u5e742\u670818\u65e5","format":false,"excerpt":"\u6c34\u8cea\u30fb\u5ec3\u6c34\u51e6\u7406\u306e\u73fe\u5834\u3067\u306f\u3001\u30a2\u30f3\u30e2\u30cb\u30a2\u6fc3\u5ea6\u306e\u7ba1\u7406\u306f\u51e6\u7406\u30d7\u30ed\u30bb\u30b9\u3092\u6b63\u5e38\u306b\u4fdd\u3061\u3001\u6cd5\u898f\u5236\u306b\u9069\u5408\u3059\u308b\u305f\u3081\u306b\u6b20\u304b\u2026","rel":"","context":"\u5206\u6790\u30fb\u6e2c\u5b9a\u95a2\u9023","block_context":{"text":"\u5206\u6790\u30fb\u6e2c\u5b9a\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/analysis\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/01\/environmental-analysis-laboratory-lpd-26008_eyecatch_.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/01\/environmental-analysis-laboratory-lpd-26008_eyecatch_.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/01\/environmental-analysis-laboratory-lpd-26008_eyecatch_.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/01\/environmental-analysis-laboratory-lpd-26008_eyecatch_.jpg?resize=700%2C400&ssl=1 2x"},"classes":[]},{"id":25608,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/cell-culture-basic-cell-culture-bpg-26026\/","url_meta":{"origin":856,"position":4},"title":"\u3010\u7b2c3\u56de\u3011Gibco\u57f9\u5730 60\u5e74\u306e\u30a4\u30ce\u30d9\u30fc\u30b7\u30e7\u30f3\u3002\u7d30\u80de\u57f9\u990a\u306e\u6b74\u53f2\u306f\u57f9\u5730\u306e\u6b74\u53f2\u3002","author":"LatB Staff","date":"2026\u5e7410\u67087\u65e5","format":false,"excerpt":"\u3053\u306e\u30d6\u30ed\u30b0\u3067\u306f\u3001\u30d0\u30a4\u30aa\u30d7\u30ed\u30c0\u30af\u30b7\u30e7\u30f3\u30c1\u30fc\u30e0\u304c\u533b\u85ac\u54c1\u88fd\u9020\u306b\u95a2\u9023\u3059\u308b\u3055\u307e\u3056\u307e\u306a\u30c8\u30d4\u30c3\u30af\u3092\u30b7\u30ea\u30fc\u30ba\u3067\u3054\u7d39\u4ecb\u2026","rel":"","context":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","block_context":{"text":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/mol-bio\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/08\/cell-culture-basic-cell-culture-bpg-26026_eyecatch.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/08\/cell-culture-basic-cell-culture-bpg-26026_eyecatch.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/08\/cell-culture-basic-cell-culture-bpg-26026_eyecatch.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/08\/cell-culture-basic-cell-culture-bpg-26026_eyecatch.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/08\/cell-culture-basic-cell-culture-bpg-26026_eyecatch.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/08\/cell-culture-basic-cell-culture-bpg-26026_eyecatch.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":24614,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/battery-manufacturing-elemental-analysis-csm-26005\/","url_meta":{"origin":856,"position":5},"title":"\u96fb\u6c60\u30ea\u30b5\u30a4\u30af\u30eb\u306b\u304a\u3051\u308b\u5143\u7d20\u5206\u6790","author":"LatB Staff","date":"2026\u5e741\u670827\u65e5","format":false,"excerpt":"\u81ea\u52d5\u8eca\u306e\u96fb\u52d5\u5316\u3068\u518d\u751f\u53ef\u80fd\u30a8\u30cd\u30eb\u30ae\u30fc\u306e\u8caf\u8535\u80fd\u529b\u306e\u5897\u52a0\u306f\u3001\u3068\u3082\u306b\u96fb\u6c60\u306b\u5bfe\u3059\u308b\u9700\u8981\u306e\u5927\u5e45\u306a\u52a0\u901f\u3092\u3082\u305f\u3089\u3057\u3066\u2026","rel":"","context":"\u5206\u6790\u30fb\u6e2c\u5b9a\u95a2\u9023","block_context":{"text":"\u5206\u6790\u30fb\u6e2c\u5b9a\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/analysis\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/01\/battery-manufacturing-elemental-analysis-csm-26005_eyecatch.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/01\/battery-manufacturing-elemental-analysis-csm-26005_eyecatch.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/01\/battery-manufacturing-elemental-analysis-csm-26005_eyecatch.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/01\/battery-manufacturing-elemental-analysis-csm-26005_eyecatch.jpg?resize=700%2C400&ssl=1 2x"},"classes":[]}],"jetpack_sharing_enabled":true,"amp_enabled":true,"jetpack_featured_media_url":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/shutterstock_389524267b-c-BLOG.jpg","_links":{"self":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/posts\/856","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/users\/988"}],"replies":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/comments?post=856"}],"version-history":[{"count":0,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/posts\/856\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/media\/3631"}],"wp:attachment":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/media?parent=856"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/categories?post=856"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/tags?post=856"},{"taxonomy":"division","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/division?post=856"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}