{"id":8605,"date":"2021-05-28T09:35:11","date_gmt":"2021-05-28T00:35:11","guid":{"rendered":"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/?p=8605"},"modified":"2024-09-18T16:36:14","modified_gmt":"2024-09-18T07:36:14","slug":"ce_basic_dne_gsd_ts_1","status":"publish","type":"post","link":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/ce_basic_dne_gsd_ts_1\/","title":{"rendered":"\u30b5\u30f3\u30ac\u30fc\u30b7\u30fc\u30b1\u30f3\u30b9\u306e\u539f\u7406"},"content":{"rendered":"<p>\u4eca\u56de\u306f\u3001\u9577\u5e74\u306b\u4e98\u3063\u3066\u30b4\u30fc\u30eb\u30c9\u30b9\u30bf\u30f3\u30c0\u30fc\u30c9\u3068\u3055\u308c\u3066\u304d\u305f\u6280\u8853\u306e\u57fa\u790e\u3092\u3001\u6539\u3081\u3066\u632f\u308a\u8fd4\u3063\u3066\u307f\u307e\u3057\u3087\u3046\u3002\u3059\u3067\u306b\u304a\u5bdf\u3057\u306e\u65b9\u3082\u3044\u308b\u304b\u3068\u601d\u3044\u307e\u3059\u304c\u3001\u305d\u3046\u3067\u3059\u3001\u30ad\u30e3\u30d4\u30e9\u30ea\u30fc\u96fb\u6c17\u6cf3\u52d5\u3092\u4f7f\u7528\u3057\u305f\u30b5\u30f3\u30ac\u30fc\u30b7\u30fc\u30b1\u30f3\u30b9\uff08\u30b5\u30f3\u30ac\u30fc\u6cd5\uff09\u306b\u3064\u3044\u3066\u306e\u304a\u8a71\u3067\u3059\u3002<\/p>\n<p>\u300c\u306a\u305c\u3001\u30b5\u30f3\u30ac\u30fc\u30b7\u30fc\u30b1\u30f3\u30b9\u3068\u547c\u3070\u308c\u3066\u3044\u308b\u306e\u304b\uff1f\u300d\u3068\u3001\u7591\u554f\u306b\u601d\u3063\u3066\u3044\u308b\u65b9\u3082\u591a\u304f\u3044\u308b\u304b\u3082\u3057\u308c\u307e\u305b\u3093\u3002\u30b5\u30f3\u30ac\u30fc\u30b7\u30fc\u30b1\u30f3\u30b9\u3068\u3044\u3046\u540d\u524d\u306f\u3001\u4eca\u304b\u308940\u5e74\u4ee5\u4e0a\u524d\u306e70\u5e74\u4ee3\u534a\u3070\u306b\u3001\u3053\u306e\u753b\u671f\u7684\u306a\u6280\u8853\u3092\u958b\u767a\u3057\u305fFrederic Sanger\u306b\u7531\u6765\u3057\u3066\u3044\u307e\u3059\u3002<\/p>\n<p>\u3067\u306f\u3001\u65e9\u901f\u30b5\u30f3\u30ac\u30fc\u30b7\u30fc\u30b1\u30f3\u30b9\u306e\u539f\u7406\u3092\u898b\u3066\u3044\u304d\u307e\u3057\u3087\u3046\u3002<br \/>\n\u203b\u30d6\u30ed\u30b0\u672c\u6587\u3067YouTube\u52d5\u753b\u5185\u5bb9\u3092\u304a\u4f1d\u3048\u3057\u3066\u3044\u307e\u3059\u306e\u3067\u3001\u5408\u308f\u305b\u3066\u3054\u89a7\u304f\u3060\u3055\u3044\u3002<\/p>\n<p><iframe loading=\"lazy\" title=\"How does Sanger Sequencing Work? \u2013 Seq It Out #1\" width=\"760\" height=\"428\" src=\"https:\/\/www.youtube.com\/embed\/e2G5zx-OJIw?feature=oembed\" frameborder=\"0\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share\" referrerpolicy=\"strict-origin-when-cross-origin\" allowfullscreen><\/iframe><\/p>\n<h2>\u30b7\u30fc\u30b1\u30f3\u30b9\u53cd\u5fdc\u306e\u539f\u7406<\/h2>\n<p>\u3059\u3079\u3066\u306f\u3001\u77ed\u9396\u306e\u30d7\u30e9\u30a4\u30de\u30fc\u304c\u3001\u6e2c\u5b9a\u9818\u57df\u306e\u96a3\u306b\u7d50\u5408\u3059\u308b\u3068\u3053\u308d\u304b\u3089\u59cb\u307e\u308a\u307e\u3059\u30024\u7a2e\u985e\u306e\u30cc\u30af\u30ec\u30aa\u30c1\u30c9\u306e\u5b58\u5728\u4e0b\u3067\u3001\u30dd\u30ea\u30e1\u30e9\u30fc\u30bc\u9175\u7d20\u304c\u3001\u92f3\u578bDNA\u306e\u76f8\u88dc\u7684\u306a\u30cc\u30af\u30ec\u30aa\u30c1\u30c9\u3092\u30d7\u30e9\u30a4\u30de\u30fc\u306b\u7d50\u5408\u3055\u305b\u3001\u4f38\u9577\u3055\u305b\u3066\u3044\u304d\u307e\u3059\u3002\u6b63\u78ba\u306aDNA\u914d\u5217\u3092\u6c7a\u5b9a\u3059\u308b\u305f\u3081\u306b\u306f\u3001\u3053\u306e\u53cd\u5fdc\u3092\u9014\u4e2d\u3067\u505c\u6b62\u3055\u305b\u3001\u4f38\u9577\u304c\u505c\u6b62\u3057\u305f\u6700\u5f8c\u306e\u5869\u57fa\u3092\u7279\u5b9a\u3059\u308b\u5fc5\u8981\u304c\u3042\u308b\u306e\u3067\u3059\u304c\u3001\u307e\u305a\u30b5\u30f3\u30ac\u30fc\u306f\u30ea\u30dc\u30cc\u30af\u30ec\u30aa\u30c1\u30c9\u304b\u3089\u9178\u7d20\u539f\u5b50\u3092\u53d6\u308a\u9664\u304f\u3053\u3068\u306b\u3088\u308a\u3001\u3053\u306e\u4f38\u9577\u53cd\u5fdc\u306e\u505c\u6b62\u3092\u5b9f\u73fe\u3057\u307e\u3057\u305f\u3002\u3053\u306e\u3088\u3046\u306a\u30cc\u30af\u30ec\u30aa\u30c1\u30c9\u306f\u3001\u30b8\u30c7\u30aa\u30ad\u30b7\u30cc\u30af\u30ec\u30aa\u30c1\u30c9\u3068\u547c\u3070\u308c\u3001\u3053\u308c\u304c\u30ea\u30dc\u30cc\u30af\u30ec\u30aa\u30c1\u30c9\u306e\u4ee3\u308f\u308a\u306b\u53d6\u308a\u8fbc\u307e\u308c\u308b\u3068\u3001\u3044\u308f\u3070\u30ec\u30f3\u30c1\u3092\u30ae\u30a2\u306b\u6295\u3052\u8fbc\u3093\u3067\u52d5\u304d\u3092\u6b62\u3081\u308b\u3088\u3046\u306b\u3001\u4f38\u9577\u53cd\u5fdc\u3092\u6b62\u3081\u308b\u50cd\u304d\u3092\u3057\u307e\u3059\u3002\u3064\u307e\u308a\u3001\u30dd\u30ea\u30e1\u30e9\u30fc\u30bc\u9175\u7d20\u306f\u3053\u306e\u5148DNA\u65ad\u7247\u306b\u3001\u901a\u5e38\u306e\u30cc\u30af\u30ec\u30aa\u30c1\u30c9\u3092\u8ffd\u52a0\u3059\u308b\u3053\u3068\u304c\u3067\u304d\u306a\u304f\u306a\u308b\u306e\u3067\u3059\u3002\u4f38\u9577\u53cd\u5fdc\u3092\u505c\u6b62\u3055\u305b\u3001\u305d\u306e\u6700\u5f8c\u306e\u5869\u57fa\u304c\u4f55\u3067\u3042\u308b\u304b\u3092\u7279\u5b9a\u3059\u308b\u305f\u3081\u3001\u30b8\u30c7\u30aa\u30ad\u30b7\u30cc\u30af\u30ec\u30aa\u30c1\u30c9\u3092\u5404\u5869\u57fa4\u3064\u306e\u7279\u5b9a\u306e\u8272\u3092\u6a19\u8b58\u3057\u3001\u8b58\u5225\u3067\u304d\u308b\u3088\u3046\u306b\u3057\u3066\u3044\u307e\u3059\u3002<br \/>\n\u3053\u306e\u3088\u3046\u306b\u3001\u30b5\u30f3\u30ac\u30fc\u30b7\u30fc\u30b1\u30f3\u30b9\u3067\u306f\u30013\u2019\u672b\u7aef\u304c\u30b8\u30c7\u30aa\u30ad\u30b7\u30cc\u30af\u30ec\u30aa\u30c1\u30c9\u3067\u7d42\u308f\u308b\u30011\u5869\u57fa\u9055\u3044\u306e\u3055\u307e\u3056\u307e\u306a\u9577\u3055\u306e\u53cd\u5fdc\u7523\u7269\u304c\u5408\u6210\u3055\u308c\u307e\u3059\u3002<\/p>\n<h2>\u30b7\u30fc\u30b1\u30f3\u30b5\u30fc\u3067\u306e\u691c\u51fa\u539f\u7406<\/h2>\n<p>\u30b7\u30fc\u30b1\u30f3\u30b9\u53cd\u5fdc\u3067\u5f97\u3089\u308c\u305f\u30011\u5869\u57fa\u9055\u3044\u306e\u3055\u307e\u3056\u307e\u306a\u9577\u3055\u306e\u53cd\u5fdc\u7523\u7269\u3092\u3001\u30b7\u30fc\u30b1\u30f3\u30b5\u30fc\u3092\u7528\u3044\u305f\u30ad\u30e3\u30d4\u30e9\u30ea\u30fc\u96fb\u6c17\u6cf3\u52d5\u3067\u5206\u96e2\u3055\u305b\u307e\u3059\u3002\u53cd\u5fdc\u7523\u7269\u306f\u3001\u30b2\u30eb\u30dd\u30ea\u30de\u30fc\u304c\u5145\u586b\u3055\u308c\u305f\u9577\u3044\u30ac\u30e9\u30b9\u30ad\u30e3\u30d4\u30e9\u30ea\u30fc\u306b\u96fb\u6c17\u7684\u306b\u53d6\u308a\u8fbc\u307e\u308c\u3001DNA\u65ad\u7247\u81ea\u4f53\u306f\u8ca0\u306e\u96fb\u8377\u3092\u5e2f\u3073\u3066\u3044\u307e\u3059\u306e\u3067\u3001\u30ad\u30e3\u30d4\u30e9\u30ea\u30fc\u96fb\u6c17\u6cf3\u52d5\u4e2d\u306f\u3001\u96fb\u754c\u3092\u5370\u52a0\u3059\u308b\u3053\u3068\u306b\u3088\u3063\u3066\u3001\u967d\u6975\u5074\u306b\u6d41\u308c\u3066\u3044\u304d\u307e\u3059\u3002\u30b2\u30eb\u306e\u4e2d\u3092\u79fb\u52d5\u3059\u308b\u901f\u5ea6\u306f\u3001DNA\u65ad\u7247\u306e\u5206\u5b50\u91cf\u306b\u53cd\u6bd4\u4f8b\u3057\u3001\u77ed\u3044\u65ad\u7247\u306f\u65e9\u304f\u6d41\u308c\u3001\u9577\u3044\u65ad\u7247\u306f\u6642\u9593\u304c\u304b\u304b\u308a\u307e\u3059\u3002\u3053\u306e\u30d7\u30ed\u30bb\u30b9\u3067\u30011\u5869\u57fa\u9055\u3044\u306e\u65ad\u7247\u3092\u5206\u96e2\u3057\u3066\u3044\u304d\u307e\u3059\u3002\u30ad\u30e3\u30d4\u30e9\u30ea\u30fc\u306e\u7aef\u306b\u306f\u7a93\u304c\u3042\u308a\u3001\u305d\u3053\u306b\u30ec\u30fc\u30b6\u30fc\u3092\u5f53\u3066\u30013\u2019\u672b\u7aef\u304c\u86cd\u5149\u3067\u6a19\u8b58\u3055\u308c\u305fDNA\u65ad\u7247\u304c\u901a\u904e\u3059\u308b\u3068\u540c\u6642\u306b\u52b1\u8d77\u3057\u307e\u3059\u3002\u52b1\u8d77\u3055\u308c\u305f\u86cd\u5149\u306f\u3001\u7279\u7570\u7684\u306a\u6ce2\u9577\u3092\u653e\u51fa\u3057\u307e\u3059\u306e\u3067\u3001\u305d\u308c\u3092\u5149\u30bb\u30f3\u30b5\u30fc\u3067\u691c\u51fa\u3057\u307e\u3059\u3002\u305d\u306e\u5f8c\u3001\u30bd\u30d5\u30c8\u30a6\u30a8\u30a2\u3067\u691c\u51fa\u3055\u308c\u305f\u4fe1\u53f7\u3092\u8aad\u307f\u53d6\u308a\u3001\u5869\u57fa\u60c5\u5831\u306b\u5909\u63db\u3057\u307e\u3059\u3002<\/p>\n<p>4\u3064\u306e\u30b8\u30c7\u30aa\u30ad\u30b7\u30cc\u30af\u30ec\u30aa\u30c1\u30c9\u5b58\u5728\u4e0b\u3067\u30b7\u30fc\u30b1\u30f3\u30b9\u53cd\u5fdc\u3092\u5b9f\u884c\u3059\u308b\u3068\u3001\u6700\u7d42\u7684\u306b\u672b\u7aef\u304c\u5404\u5869\u57fa\u306e\u86cd\u5149\u3067\u6a19\u8b58\u3055\u308c\u305f1\u5869\u57fa\u9055\u3044\u306eDNA\u65ad\u7247\u304c\u5f97\u3089\u308c\u30011\u5869\u57fa\u9055\u3044\u3067\u5206\u96e2\u3001\u6e2c\u5b9a\u3055\u308c\u307e\u3059\u3002\u305d\u3057\u3066\u3001\u30ab\u30e9\u30d5\u30eb\u306a\u6ce2\u5f62\u3067\u5869\u57fa\u914d\u5217\u304c\u793a\u3055\u308c\u305f\u30c7\u30fc\u30bf\u30d5\u30a1\u30a4\u30eb\u3068\u3001\u914d\u5217\u60c5\u5831\u306e\u30c6\u30ad\u30b9\u30c8\u30d5\u30a1\u30a4\u30eb\u304c\u5f97\u3089\u308c\u308b\u3001\u3068\u3044\u3046\u6d41\u308c\u3067\u3059\u3002<\/p>\n<p>\u3053\u308c\u304c\u30b5\u30f3\u30ac\u30fc\u30b7\u30fc\u30b1\u30f3\u30b9\u306e\u539f\u7406\u3067\u3059\u3002<\/p>\n<h2>\u307e\u3068\u3081<\/h2>\n<p>\u30fb\u30b5\u30f3\u30ac\u30fc\u30b7\u30fc\u30b1\u30f3\u30b9\u306f\u3001Frederic Sanger\u304c\u958b\u767a\u3057\u305f\u6280\u8853<br \/>\n\u30fb\u30b7\u30fc\u30b1\u30f3\u30b9\u53cd\u5fdc\u3067\u306f\u3001\u9014\u4e2d\u3067\u4f38\u9577\u53cd\u5fdc\u3092\u505c\u6b62\u3057\u30013\u2019\u672b\u7aef\u304c\u5404\u5869\u57fa\u3092\u8b58\u5225\u3059\u308b\u86cd\u5149\u3067\u6a19\u8b58\u3055\u308c\u305f\u30011\u5869\u57fa\u9055\u3044\u306e\u65ad\u7247\u3092\u5408\u6210<br \/>\n\u30fb\u30b7\u30fc\u30b1\u30f3\u30b5\u30fc\u3067\u306e\u30ad\u30e3\u30d4\u30e9\u30ea\u30fc\u96fb\u6c17\u6cf3\u52d5\u3067\u30011\u5869\u57fa\u9055\u3044\u306e\u65ad\u7247\u3092\u5206\u96e2\u3057\u3001\u6d41\u308c\u3066\u304d\u305f\u9806\u306b3\u2019\u672b\u7aef\u306e\u86cd\u5149\u3092\u691c\u51fa\u3059\u308b\u3053\u3068\u3067\u3001\u5869\u57fa\u914d\u5217\u3092\u6c7a\u5b9a<\/p>\n<h3>\u3010\u7121\u6599\u516c\u958b\u4e2d\u3011\u30b5\u30f3\u30ac\u30fc\u30b7\u30fc\u30b1\u30f3\u30b9\u306e\u57fa\u790e<\/h3>\n<p>\u3053\u306e\u30b1\u30df\u30b9\u30c8\u30ea\u30fc\u30ac\u30a4\u30c9\u3067\u306f\u3001\u30ef\u30fc\u30af\u30d5\u30ed\u30fc\u304b\u3089\u30a2\u30d7\u30ea\u30b1\u30fc\u30b7\u30e7\u30f3\u307e\u3067\u30b5\u30f3\u30ac\u30fc\u30b7\u30fc\u30b1\u30f3\u30b9\u306e\u57fa\u672c\u539f\u7406\u3092\u5b66\u3079\u307e\u3059\u3002<\/p>\n<p><a class=\"btn btn-red\" href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/global\/forms\/sanger-sequencing-guide-download.html?CID=gsd_cap_sbu_r04_jp_cp1425_pjt7502_gsd00000_0so_blg_op_awa_og_s00_Social_LAB_dne9\" target=\"_blank\" rel=\"noopener noreferrer\">\u30c0\u30a6\u30f3\u30ed\u30fc\u30c9\u3059\u308b<\/a><\/p>\n<p>\u7814\u7a76\u7528\u306b\u306e\u307f\u4f7f\u7528\u3067\u304d\u307e\u3059\u3002\u8a3a\u65ad\u7528\u306b\u306f\u4f7f\u7528\u3044\u305f\u3060\u3051\u307e\u305b\u3093\u3002<\/p>\n","protected":false},"excerpt":{"rendered":"<p>\u4eca\u56de\u306f\u3001\u9577\u5e74\u306b\u4e98\u3063\u3066\u30b4\u30fc\u30eb\u30c9\u30b9\u30bf\u30f3\u30c0\u30fc\u30c9\u3068\u3055\u308c\u3066\u304d\u305f\u6280\u8853\u306e\u57fa\u790e\u3092\u3001\u6539\u3081\u3066\u632f\u308a\u8fd4\u3063\u3066\u307f\u307e\u3057\u3087\u3046\u3002\u3059\u3067\u306b\u304a\u5bdf\u3057\u306e\u65b9\u3082\u3044\u308b\u304b\u3068\u601d\u3044\u307e\u3059\u304c\u3001\u305d\u3046\u3067\u3059\u3001\u30ad\u30e3\u30d4\u30e9\u30ea\u30fc\u96fb\u6c17\u6cf3\u52d5\u3092\u4f7f\u7528\u3057\u305f\u30b5\u30f3\u30ac\u30fc\u30b7\u30fc\u30b1\u30f3\u30b9\uff08\u30b5\u30f3\u30ac\u30fc\u6cd5\uff09\u306b\u3064\u3044\u3066\u306e\u304a\u8a71\u3067<\/p>\n","protected":false},"author":975,"featured_media":9636,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_monsterinsights_skip_tracking":false,"_genesis_hide_title":false,"_genesis_hide_breadcrumbs":false,"_genesis_hide_singular_image":false,"_genesis_hide_footer_widgets":false,"_genesis_custom_body_class":"","_genesis_custom_post_class":"","_genesis_layout":"","_jetpack_newsletter_access":"","_jetpack_dont_email_post_to_subs":false,"_jetpack_newsletter_tier_id":0,"_jetpack_memberships_contains_paywalled_content":false,"_jetpack_feature_clip_id":0,"_jetpack_memberships_contains_paid_content":false,"footnotes":"","jetpack_post_was_ever_published":false},"categories":[156],"tags":[172],"division":[],"class_list":{"0":"post-8605","1":"post","2":"type-post","3":"status-publish","4":"format-standard","5":"has-post-thumbnail","7":"category-mol-bio","8":"tag-ce","9":"entry"},"_selected_authors":"","_selected_reviewers":"","acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v27.8 (Yoast SEO v27.8) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>\u30b5\u30f3\u30ac\u30fc\u30b7\u30fc\u30b1\u30f3\u30b9\u306e\u539f\u7406 - Learning at the Bench<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/ce_basic_dne_gsd_ts_1\/\" \/>\n<meta property=\"og:locale\" content=\"ja_JP\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"\u30b5\u30f3\u30ac\u30fc\u30b7\u30fc\u30b1\u30f3\u30b9\u306e\u539f\u7406\" \/>\n<meta property=\"og:description\" content=\"\u4eca\u56de\u306f\u3001\u9577\u5e74\u306b\u4e98\u3063\u3066\u30b4\u30fc\u30eb\u30c9\u30b9\u30bf\u30f3\u30c0\u30fc\u30c9\u3068\u3055\u308c\u3066\u304d\u305f\u6280\u8853\u306e\u57fa\u790e\u3092\u3001\u6539\u3081\u3066\u632f\u308a\u8fd4\u3063\u3066\u307f\u307e\u3057\u3087\u3046\u3002\u3059\u3067\u306b\u304a\u5bdf\u3057\u306e\u65b9\u3082\u3044\u308b\u304b\u3068\u601d\u3044\u307e\u3059\u304c\u3001\u305d\u3046\u3067\u3059\u3001\u30ad\u30e3\u30d4\u30e9\u30ea\u30fc\u96fb\u6c17\u6cf3\u52d5\u3092\u4f7f\u7528\u3057\u305f\u30b5\u30f3\u30ac\u30fc\u30b7\u30fc\u30b1\u30f3\u30b9\uff08\u30b5\u30f3\u30ac\u30fc\u6cd5\uff09\u306b\u3064\u3044\u3066\u306e\u304a\u8a71\u3067\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/ce_basic_dne_gsd_ts_1\/\" \/>\n<meta property=\"og:site_name\" content=\"Learning at the Bench\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/ThermoFisherJapan\" \/>\n<meta property=\"article:published_time\" content=\"2021-05-28T00:35:11+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2024-09-18T07:36:14+00:00\" \/>\n<meta property=\"og:image\" content=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2021\/05\/shutterstock_1079848190-scaled.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"2560\" \/>\n\t<meta property=\"og:image:height\" content=\"1707\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"LatB Staff\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:creator\" content=\"@ThermoFisherJP\" \/>\n<meta name=\"twitter:site\" content=\"@ThermoFisherJP\" \/>\n<meta name=\"twitter:label1\" content=\"\u57f7\u7b46\u8005\" \/>\n\t<meta name=\"twitter:data1\" content=\"LatB Staff\" \/>\n\t<meta name=\"twitter:label2\" content=\"\u63a8\u5b9a\u8aad\u307f\u53d6\u308a\u6642\u9593\" \/>\n\t<meta name=\"twitter:data2\" content=\"5\u5206\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/ce_basic_dne_gsd_ts_1\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/ce_basic_dne_gsd_ts_1\\\/\"},\"author\":{\"name\":\"LatB Staff\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#\\\/schema\\\/person\\\/bdbe319a2001f279ddce6ab8eaad1253\"},\"headline\":\"\u30b5\u30f3\u30ac\u30fc\u30b7\u30fc\u30b1\u30f3\u30b9\u306e\u539f\u7406\",\"datePublished\":\"2021-05-28T00:35:11+00:00\",\"dateModified\":\"2024-09-18T07:36:14+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/ce_basic_dne_gsd_ts_1\\\/\"},\"wordCount\":18,\"commentCount\":0,\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/ce_basic_dne_gsd_ts_1\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2021\\\/05\\\/shutterstock_1079848190-scaled.jpg\",\"keywords\":[\"\u30ad\u30e3\u30d4\u30e9\u30ea\u30fc\u96fb\u6c17\u6cf3\u52d5\"],\"articleSection\":[\"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023\"],\"inLanguage\":\"ja\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/ce_basic_dne_gsd_ts_1\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/ce_basic_dne_gsd_ts_1\\\/\",\"url\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/ce_basic_dne_gsd_ts_1\\\/\",\"name\":\"\u30b5\u30f3\u30ac\u30fc\u30b7\u30fc\u30b1\u30f3\u30b9\u306e\u539f\u7406 - Learning at the Bench\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/ce_basic_dne_gsd_ts_1\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/ce_basic_dne_gsd_ts_1\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2021\\\/05\\\/shutterstock_1079848190-scaled.jpg\",\"datePublished\":\"2021-05-28T00:35:11+00:00\",\"dateModified\":\"2024-09-18T07:36:14+00:00\",\"author\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#\\\/schema\\\/person\\\/bdbe319a2001f279ddce6ab8eaad1253\"},\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/ce_basic_dne_gsd_ts_1\\\/#breadcrumb\"},\"inLanguage\":\"ja\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/ce_basic_dne_gsd_ts_1\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"ja\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/ce_basic_dne_gsd_ts_1\\\/#primaryimage\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2021\\\/05\\\/shutterstock_1079848190-scaled.jpg\",\"contentUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2021\\\/05\\\/shutterstock_1079848190-scaled.jpg\",\"width\":2560,\"height\":1707},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/ce_basic_dne_gsd_ts_1\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"\u30b5\u30f3\u30ac\u30fc\u30b7\u30fc\u30b1\u30f3\u30b9\u306e\u539f\u7406\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#website\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/\",\"name\":\"Learning at the Bench\",\"description\":\"\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"ja\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#\\\/schema\\\/person\\\/bdbe319a2001f279ddce6ab8eaad1253\",\"name\":\"LatB Staff\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"ja\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g\",\"caption\":\"LatB Staff\"},\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/author\\\/lgbadmin\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"\u30b5\u30f3\u30ac\u30fc\u30b7\u30fc\u30b1\u30f3\u30b9\u306e\u539f\u7406 - Learning at the Bench","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/ce_basic_dne_gsd_ts_1\/","og_locale":"ja_JP","og_type":"article","og_title":"\u30b5\u30f3\u30ac\u30fc\u30b7\u30fc\u30b1\u30f3\u30b9\u306e\u539f\u7406","og_description":"\u4eca\u56de\u306f\u3001\u9577\u5e74\u306b\u4e98\u3063\u3066\u30b4\u30fc\u30eb\u30c9\u30b9\u30bf\u30f3\u30c0\u30fc\u30c9\u3068\u3055\u308c\u3066\u304d\u305f\u6280\u8853\u306e\u57fa\u790e\u3092\u3001\u6539\u3081\u3066\u632f\u308a\u8fd4\u3063\u3066\u307f\u307e\u3057\u3087\u3046\u3002\u3059\u3067\u306b\u304a\u5bdf\u3057\u306e\u65b9\u3082\u3044\u308b\u304b\u3068\u601d\u3044\u307e\u3059\u304c\u3001\u305d\u3046\u3067\u3059\u3001\u30ad\u30e3\u30d4\u30e9\u30ea\u30fc\u96fb\u6c17\u6cf3\u52d5\u3092\u4f7f\u7528\u3057\u305f\u30b5\u30f3\u30ac\u30fc\u30b7\u30fc\u30b1\u30f3\u30b9\uff08\u30b5\u30f3\u30ac\u30fc\u6cd5\uff09\u306b\u3064\u3044\u3066\u306e\u304a\u8a71\u3067","og_url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/ce_basic_dne_gsd_ts_1\/","og_site_name":"Learning at the Bench","article_publisher":"https:\/\/www.facebook.com\/ThermoFisherJapan","article_published_time":"2021-05-28T00:35:11+00:00","article_modified_time":"2024-09-18T07:36:14+00:00","og_image":[{"width":2560,"height":1707,"url":"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2021\/05\/shutterstock_1079848190-scaled.jpg","type":"image\/jpeg"}],"author":"LatB Staff","twitter_card":"summary_large_image","twitter_creator":"@ThermoFisherJP","twitter_site":"@ThermoFisherJP","twitter_misc":{"\u57f7\u7b46\u8005":"LatB Staff","\u63a8\u5b9a\u8aad\u307f\u53d6\u308a\u6642\u9593":"5\u5206"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/ce_basic_dne_gsd_ts_1\/#article","isPartOf":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/ce_basic_dne_gsd_ts_1\/"},"author":{"name":"LatB Staff","@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#\/schema\/person\/bdbe319a2001f279ddce6ab8eaad1253"},"headline":"\u30b5\u30f3\u30ac\u30fc\u30b7\u30fc\u30b1\u30f3\u30b9\u306e\u539f\u7406","datePublished":"2021-05-28T00:35:11+00:00","dateModified":"2024-09-18T07:36:14+00:00","mainEntityOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/ce_basic_dne_gsd_ts_1\/"},"wordCount":18,"commentCount":0,"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/ce_basic_dne_gsd_ts_1\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2021\/05\/shutterstock_1079848190-scaled.jpg","keywords":["\u30ad\u30e3\u30d4\u30e9\u30ea\u30fc\u96fb\u6c17\u6cf3\u52d5"],"articleSection":["\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023"],"inLanguage":"ja","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/ce_basic_dne_gsd_ts_1\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/ce_basic_dne_gsd_ts_1\/","url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/ce_basic_dne_gsd_ts_1\/","name":"\u30b5\u30f3\u30ac\u30fc\u30b7\u30fc\u30b1\u30f3\u30b9\u306e\u539f\u7406 - Learning at the Bench","isPartOf":{"@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/ce_basic_dne_gsd_ts_1\/#primaryimage"},"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/ce_basic_dne_gsd_ts_1\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2021\/05\/shutterstock_1079848190-scaled.jpg","datePublished":"2021-05-28T00:35:11+00:00","dateModified":"2024-09-18T07:36:14+00:00","author":{"@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#\/schema\/person\/bdbe319a2001f279ddce6ab8eaad1253"},"breadcrumb":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/ce_basic_dne_gsd_ts_1\/#breadcrumb"},"inLanguage":"ja","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/ce_basic_dne_gsd_ts_1\/"]}]},{"@type":"ImageObject","inLanguage":"ja","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/ce_basic_dne_gsd_ts_1\/#primaryimage","url":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2021\/05\/shutterstock_1079848190-scaled.jpg","contentUrl":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2021\/05\/shutterstock_1079848190-scaled.jpg","width":2560,"height":1707},{"@type":"BreadcrumbList","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/ce_basic_dne_gsd_ts_1\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/"},{"@type":"ListItem","position":2,"name":"\u30b5\u30f3\u30ac\u30fc\u30b7\u30fc\u30b1\u30f3\u30b9\u306e\u539f\u7406"}]},{"@type":"WebSite","@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#website","url":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/","name":"Learning at the Bench","description":"","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"ja"},{"@type":"Person","@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#\/schema\/person\/bdbe319a2001f279ddce6ab8eaad1253","name":"LatB Staff","image":{"@type":"ImageObject","inLanguage":"ja","@id":"https:\/\/secure.gravatar.com\/avatar\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g","caption":"LatB Staff"},"url":"https:\/\/admin.acceleratingscience.com\/author\/lgbadmin\/"}]}},"taxonomy_info":{"category":[{"value":156,"label":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023"}],"post_tag":[{"value":172,"label":"\u30ad\u30e3\u30d4\u30e9\u30ea\u30fc\u96fb\u6c17\u6cf3\u52d5"}]},"featured_image_src_large":["https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2021\/05\/shutterstock_1079848190-1024x683.jpg",760,507,true],"author_info":{"display_name":"LatB Staff","author_link":"https:\/\/admin.acceleratingscience.com\/author\/lgbadmin\/"},"comment_info":1,"category_info":[{"term_id":156,"name":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","slug":"mol-bio","term_group":0,"term_taxonomy_id":156,"taxonomy":"category","description":"","parent":0,"count":538,"filter":"raw","meta":[],"cat_ID":156,"category_count":538,"category_description":"","cat_name":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","category_nicename":"mol-bio","category_parent":0}],"tag_info":[{"term_id":172,"name":"\u30ad\u30e3\u30d4\u30e9\u30ea\u30fc\u96fb\u6c17\u6cf3\u52d5","slug":"ce","term_group":0,"term_taxonomy_id":172,"taxonomy":"post_tag","description":"","parent":0,"count":34,"filter":"raw","meta":[]}],"jetpack-related-posts":[{"id":24647,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/sanger-seq-mutational-analysis-gsd-ts-ce-26007\/","url_meta":{"origin":8605,"position":0},"title":"\u30de\u30a4\u30ca\u30fc\u5909\u7570\u3092\u691c\u51fa\uff01Minor Variant Finder\u30bd\u30d5\u30c8\u30a6\u30a8\u30a2","author":"LatB Staff","date":"2026\u5e742\u67089\u65e5","format":false,"excerpt":"\u30ad\u30e3\u30d4\u30e9\u30ea\u30fc\u30b7\u30fc\u30b1\u30f3\u30b5\u3067\u306f\u300125%\u7a0b\u5ea6\u306e\u5272\u5408\u306e\u5909\u7570\u3092\u691c\u51fa\u3059\u308b\u3053\u3068\u304c\u3067\u304d\u307e\u3059\u304c\u3001\u3053\u308c\u3088\u308a\u3082\u4f4e\u3044\u5272\u5408\u306e\u5909\u2026","rel":"","context":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","block_context":{"text":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/mol-bio\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/01\/sanger-seq-mutational-analysis-gsd-ts-ce-26007_eyecatch.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/01\/sanger-seq-mutational-analysis-gsd-ts-ce-26007_eyecatch.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/01\/sanger-seq-mutational-analysis-gsd-ts-ce-26007_eyecatch.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/01\/sanger-seq-mutational-analysis-gsd-ts-ce-26007_eyecatch.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/01\/sanger-seq-mutational-analysis-gsd-ts-ce-26007_eyecatch.jpg?resize=1050%2C600&ssl=1 3x"},"classes":[]},{"id":23665,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/pcr-dna-gsd-ts-tr-25064\/","url_meta":{"origin":8605,"position":1},"title":"\u3010\u3084\u3063\u3066\u307f\u305f\u3011PCR\u306e\u30a2\u30cb\u30fc\u30ea\u30f3\u30b0\u6e29\u5ea6\u3092\u601d\u3044\u5207\u308a\u632f\u3063\u3066\u307f\u305f","author":"LatB Staff","date":"2025\u5e7410\u670828\u65e5","format":false,"excerpt":"\u65b0\u305f\u306aPCR\u691c\u51fa\u7cfb\u3092\u69cb\u7bc9\u3059\u308b\u5834\u5408\u3001\u4f55\u3088\u308a\u3082\u30d7\u30e9\u30a4\u30de\u30fc\u306e\u914d\u5217\u304c\u91cd\u8981\u3068\u3044\u3046\u3053\u3068\u306f\u591a\u304f\u306e\u65b9\u304c\u8a8d\u8b58\u3057\u3066\u3044\u308b\u306e\u2026","rel":"","context":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","block_context":{"text":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/mol-bio\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/10\/pcr-dna-gsd-ts-tr-25064_eyecatch-scaled.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/10\/pcr-dna-gsd-ts-tr-25064_eyecatch-scaled.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/10\/pcr-dna-gsd-ts-tr-25064_eyecatch-scaled.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/10\/pcr-dna-gsd-ts-tr-25064_eyecatch-scaled.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/10\/pcr-dna-gsd-ts-tr-25064_eyecatch-scaled.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/10\/pcr-dna-gsd-ts-tr-25064_eyecatch-scaled.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":24953,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/ngs-gene-expression-csd-ts-ion-26011\/","url_meta":{"origin":8605,"position":2},"title":"\u30e9\u30a4\u30d6\u30e9\u30ea\u30fc\u8abf\u88fd\u306e\u81ea\u52d5\u5316\u3067NGS\u306e\u53ef\u80fd\u6027\u3092\u5e83\u3052\u308b\u2015Ion Chef\u30b7\u30b9\u30c6\u30e0\u304c\u5909\u3048\u308b\u7814\u7a76\u5ba4\u306e\u30ef\u30fc\u30af\u30d5\u30ed\u30fc","author":"LatB Staff","date":"2026\u5e744\u670810\u65e5","format":false,"excerpt":"\u524d\u51e6\u7406\u306e\u81ea\u52d5\u5316\u304c\u3001NGS\u306e\u65b0\u3057\u3044\u6a19\u6e96\u3092\u3064\u304f\u308b\u6b21\u4e16\u4ee3\u30b7\u30fc\u30b1\u30f3\u30b7\u30f3\u30b0\uff08NGS\uff09\u304c\u65e5\u5e38\u7684\u306a\u7814\u7a76\u30c4\u30fc\u30eb\u3068\u306a\u3063\u2026","rel":"","context":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","block_context":{"text":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/mol-bio\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/02\/ngs-gene-expression-csd-ts-ion-26011_eyecatch.jpeg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/02\/ngs-gene-expression-csd-ts-ion-26011_eyecatch.jpeg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/02\/ngs-gene-expression-csd-ts-ion-26011_eyecatch.jpeg?resize=525%2C300&ssl=1 1.5x"},"classes":[]},{"id":23864,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/protein-expression-cloning-bid-ts-mbr-25070\/","url_meta":{"origin":8605,"position":3},"title":"\u521d\u5fc3\u8005\u3067\u3082\u5b89\u5fc3\uff01\u7c21\u5358\u306b\u3067\u304d\u308b\u767a\u73fe\u30d9\u30af\u30bf\u30fc\u306e\u4f5c\u308a\u65b9\uff1a\u4eba\u5de5\u907a\u4f1d\u5b50\u5408\u6210\u30b5\u30fc\u30d3\u30b9\u306e\u5229\u7528\u6cd5","author":"LatB Staff","date":"2025\u5e7411\u670813\u65e5","format":false,"excerpt":"\u30bf\u30f3\u30d1\u30af\u8cea\u767a\u73fe\u5b9f\u9a13\u306b\u306f\u767a\u73fe\u30d9\u30af\u30bf\u30fc\u304c\u6b20\u304b\u305b\u307e\u305b\u3093\u304c\u3001\u4e00\u304b\u3089\u4f5c\u308b\u3068\u306a\u308b\u3068\u3001\u304b\u306a\u308a\u306e\u624b\u9593\u3068\u7d4c\u9a13\u304c\u5fc5\u8981\u3067\u3059\u2026","rel":"","context":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","block_context":{"text":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/mol-bio\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/10\/protein-expression-cloning-bid-ts-mbr-25070_eyecatch.png?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/10\/protein-expression-cloning-bid-ts-mbr-25070_eyecatch.png?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/10\/protein-expression-cloning-bid-ts-mbr-25070_eyecatch.png?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/10\/protein-expression-cloning-bid-ts-mbr-25070_eyecatch.png?resize=700%2C400&ssl=1 2x"},"classes":[]},{"id":25540,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/cloning-cell-separation-bid-ts-mbr-26023\/","url_meta":{"origin":8605,"position":4},"title":"\u5927\u8178\u83cc\u306e\u98fc\u3044\u65b92\uff5e\u5b9f\u969b\u306b\u57f9\u990a\u3057\u3066\u307f\u3088\u3046","author":"LatB Staff","date":"2026\u5e748\u670826\u65e5","format":false,"excerpt":"\u30d6\u30ed\u30b0\u300c\u5927\u8178\u83cc\u306e\u98fc\u3044\u65b9\uff5e\u5b9f\u9a13\u306b\u5fc5\u8981\u306a\u8a2d\u5099\u3092\u305d\u308d\u3048\u3088\u3046\u300d\u3067\u306f\u3001\u30af\u30ed\u30fc\u30cb\u30f3\u30b0\u3084\u7d44\u307f\u63db\u3048\u30bf\u30f3\u30d1\u30af\u8cea\u767a\u73fe\u306e\u7528\u2026","rel":"","context":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","block_context":{"text":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/mol-bio\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/08\/cloning-cell-separation-bid-ts-mbr-26023_eyecatch.png?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/08\/cloning-cell-separation-bid-ts-mbr-26023_eyecatch.png?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/08\/cloning-cell-separation-bid-ts-mbr-26023_eyecatch.png?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/08\/cloning-cell-separation-bid-ts-mbr-26023_eyecatch.png?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/08\/cloning-cell-separation-bid-ts-mbr-26023_eyecatch.png?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/08\/cloning-cell-separation-bid-ts-mbr-26023_eyecatch.png?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":24382,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/cell-imaging-fluorescent-dye-bid-ts-mbr-25075\/","url_meta":{"origin":8605,"position":5},"title":"Cell Painting Assay\u3067\u7528\u3044\u3089\u308c\u308b\u8a66\u85ac\u306b\u3064\u3044\u3066 (Hoechst\u3092\u7528\u3044\u305f\u6838\u67d3\u8272\uff09","author":"LatB Staff","date":"2025\u5e7412\u670810\u65e5","format":false,"excerpt":"\u8fd1\u5e74\u3001\u30bb\u30eb\u30da\u30a4\u30f3\u30c6\u30a3\u30f3\u30b0\uff08Cell Painting\uff09\u3068\u3044\u3046\u30a2\u30c3\u30bb\u30a4\u65b9\u6cd5\u304c\u5e83\u307e\u308a\u3064\u3064\u3042\u308a\u307e\u3059\u3002\u7d30\u80de\u306b\u2026","rel":"","context":"\u7d30\u80de\u57f9\u990a\u30fb\u30a4\u30e1\u30fc\u30b8\u30f3\u30b0","block_context":{"text":"\u7d30\u80de\u57f9\u990a\u30fb\u30a4\u30e1\u30fc\u30b8\u30f3\u30b0","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/cell\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/11\/cell-imaging-fluorescent-dye-bid-ts-mbr-25075_eyecatch-scaled.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/11\/cell-imaging-fluorescent-dye-bid-ts-mbr-25075_eyecatch-scaled.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/11\/cell-imaging-fluorescent-dye-bid-ts-mbr-25075_eyecatch-scaled.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/11\/cell-imaging-fluorescent-dye-bid-ts-mbr-25075_eyecatch-scaled.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/11\/cell-imaging-fluorescent-dye-bid-ts-mbr-25075_eyecatch-scaled.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/11\/cell-imaging-fluorescent-dye-bid-ts-mbr-25075_eyecatch-scaled.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]}],"jetpack_sharing_enabled":true,"amp_enabled":true,"jetpack_featured_media_url":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2021\/05\/shutterstock_1079848190-scaled.jpg","_links":{"self":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/posts\/8605","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/users\/975"}],"replies":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/comments?post=8605"}],"version-history":[{"count":0,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/posts\/8605\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/media\/9636"}],"wp:attachment":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/media?parent=8605"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/categories?post=8605"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/tags?post=8605"},{"taxonomy":"division","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/division?post=8605"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}