{"id":900,"date":"2018-12-27T00:00:00","date_gmt":"2018-12-27T00:00:00","guid":{"rendered":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/cancer3\/"},"modified":"2025-02-28T11:17:52","modified_gmt":"2025-02-28T02:17:52","slug":"cancer3","status":"publish","type":"post","link":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/cancer3\/","title":{"rendered":"\u3010\u3044\u307e\u3055\u3089\u805e\u3051\u306a\u3044\u304c\u3093\u306e\u57fa\u790e 3\u3011\u304c\u3093\u3068\u5fae\u5c0f\u74b0\u5883\u306e\u95a2\u4fc2\u3068\u306f\uff1f"},"content":{"rendered":"<p><br \/>\n19\u4e16\u7d00\u306b\u3001\u708e\u75c7\u30a4\u30d9\u30f3\u30c8\u3068\u304c\u3093\u9032\u884c\u3068\u306e\u95a2\u9023\u6027\u306b\u95a2\u3059\u308b\u6700\u521d\u306e\u77e5\u898b\u304c\u5831\u544a\u3055\u308c\u307e\u3057\u305f\u3002\u3053\u308c\u3089\u306e\u5148\u306e\u77e5\u898b\u3092\u30b5\u30dd\u30fc\u30c8\u3059\u308b\u75ab\u5b66\u7684\u3001\u5b9f\u9a13\u7684\u3001\u304a\u3088\u3073\u81e8\u5e8a\u7684\u8a3c\u62e0\u3092\u63d0\u4f9b\u3059\u308b\u6570\u591a\u304f\u306e\u5831\u544a\u304c\u5287\u7684\u306b\u5897\u52a0\u3057\u3066\u304d\u3066\u3044\u307e\u3059\u3002\u73fe\u5728\u3001\u304c\u3093\u306e\u767a\u751f\u306b\u304a\u3051\u308b\u30ea\u30b9\u30af\u30d5\u30a1\u30af\u30bf\u30fc\u3068\u3057\u3066\u306e\u6162\u6027\u708e\u75c7\u306e\u5b58\u5728\u306b\u95a2\u3057\u3066\u306f\u591a\u5927\u306a\u60c5\u5831\u304c\u5b58\u5728\u3057\u307e\u3059\u304c\u3001\u3053\u306e\u30d7\u30ed\u30bb\u30b9\u3092\u8a98\u5c0e\u3059\u308b\u6b63\u78ba\u306a\u30e1\u30ab\u30cb\u30ba\u30e0\u306f\u5b8c\u5168\u306b\u306f\u7406\u89e3\u3055\u308c\u3066\u3044\u307e\u305b\u3093<sup>*1<\/sup>\u3002<br \/>\n\u524d\u304c\u3093\u671f\u306f\u3001\u7d30\u80de\u306e\u6210\u9577\u304a\u3088\u3073\u751f\u5b58\u306b\u5fc5\u8981\u306a\u7d4c\u8def\u306e\u6d3b\u6027\u5316\u3092\u3082\u305f\u3089\u3059\u30b2\u30ce\u30e0\u7570\u5e38\u3092\u7279\u5fb4\u3068\u3057\u307e\u3059\u3002\u5fae\u5c0f\u74b0\u5883\u306b\u306f\u3001\u6025\u6027\u640d\u50b7\u306b\u5bfe\u3059\u308b\u7d44\u7e54\u53cd\u5fdc\u306b\u985e\u4f3c\u3059\u308b\u30d7\u30ed\u30bb\u30b9\u3092\u4ecb\u3057\u3066\u816b\u760d\u5f62\u6210\u8868\u73fe\u578b\u3092\u3055\u3089\u306b\u30b5\u30dd\u30fc\u30c8\u304a\u3088\u3073\u4fc3\u9032\u3059\u308b\u514d\u75ab\u7d30\u80de\u304c\u542b\u307e\u308c\u307e\u3059\u3002\u6162\u6027\u708e\u75c7\u30a4\u30d9\u30f3\u30c8\u304c\u91ce\u653e\u3057\u3067\u3001\u816b\u760d\u5fae\u5c0f\u74b0\u5883\u306b\u4e00\u8cab\u3057\u3066\u5b58\u5728\u3057\u3066\u3044\u308b\u3068\u3001\u816b\u760d\u9032\u884c\uff08\u6d78\u6f64\u304a\u3088\u3073\u8ee2\u79fb\uff09\u304c\u4fc3\u9032\u3055\u308c\u307e\u3059<sup>*2<\/sup>\u3002 \u65b0\u751f\u7269\u306e\u9032\u884c\u306f\u3001\u304c\u3093\u7d30\u80de\u5358\u72ec\u306e\u5897\u6b96\u30d7\u30ed\u30bb\u30b9\u3067\u306f\u816b\u760d\u306e\u9032\u884c\u3092\u5f15\u304d\u8d77\u3053\u3059\u306e\u306b\u4e0d\u5341\u5206\u3067\u3042\u308b\u3068\u3055\u308c\u3066\u304d\u307e\u3057\u305f\u304c\u3001\u305d\u308c\u3088\u308a\u3082\u3080\u3057\u308d\u3001\u708e\u75c7\u7d30\u80de\u3001\u6210\u9577\u56e0\u5b50\u3001\u6d3b\u6027\u5316\u9593\u8cea\u7d30\u80de\u3001\u304a\u3088\u3073DNA\u640d\u50b7\u5264\u304c\u8c4a\u5bcc\u306a\u5fae\u5c0f\u74b0\u5883\u306e\u72b6\u6cc1\u306b\u304a\u3051\u308b\u6301\u7d9a\u7684\u306a\u5897\u6b96\u306b\u4f9d\u5b58\u3057\u3066\u3044\u307e\u3059\uff08\u56f33.1\uff09<sup>*3<\/sup>\u3002<\/p>\n<p>\u203b\u672c\u8a18\u4e8b\u306e\u672b\u5c3e\u306b\u304a\u3044\u3066\u3001\u816b\u760d\u95a2\u9023\u708e\u75c7\u3092\u8a55\u4fa1\u3059\u308b\u305f\u3081\u306e\u6297\u4f53\u30d9\u30fc\u30b9\u306e\u30c4\u30fc\u30eb\u306b\u3064\u3044\u3066\u4f53\u7cfb\u7684\u306b\u5b66\u3079\u308b\u7121\u6599\u30b3\u30f3\u30c6\u30f3\u30c4\u3092\u7d39\u4ecb\u3057\u3066\u3044\u307e\u3059\u3002<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"size-full wp-image-2920 aligncenter\" src=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/1-12.jpg\" alt=\"\u304c\u3093\u9032\u884c\u306b\u304a\u3051\u308b\u74b0\u5883\u8981\u56e0\u3001\u907a\u4f1d\u7684\u4e0d\u5b89\u5b9a\u6027\u3001\u304a\u3088\u3073\u708e\u75c7\u306e\u9593\u306e\u8907\u96d1\u306a\u76f8 \u4e92\u4f5c\u7528\u3092\u793a\u3059\u7c21\u7565\u56f3\" width=\"397\" height=\"600\" \/><\/p>\n<p>\u514d\u75ab\u7d30\u80de\u76e3\u8996\u306e\u4e3b\u8981\u306a\u5f79\u5272\u306e\u4e00\u3064\u306f\u3001\u7d44\u7e54\u306e\u69cb\u9020\u304a\u3088\u3073\u6a5f\u80fd\u3092\u78ba\u5b9f\u306b\u7dad\u6301\u3057\u3001\u75c5\u539f\u4f53\u304b\u3089\u5bbf\u4e3b\u3092\u4fdd\u8b77\u3059\u308b\u6025\u6027\u708e\u75c7\u53cd\u5fdc\u3092\u4ea2\u9032\u3055\u305b\u308b\u3053\u3068\u3067\u3059\u3002\u611f\u67d3\u3084\u5916\u50b7\u306b\u3088\u308b\u4fb5\u8972\u3092\u53d7\u3051\u3066\u3044\u308b\u9593\u3001\u9846\u7c92\u7403\u304c\u6025\u6027\u708e\u75c7\u90e8\u4f4d\u306b\u52d5\u54e1\u3055\u308c\u3001\u7d44\u7e54\u306e\u640d\u50b7\u3092\u9650\u5c40\u5316\u3057\u3001\u6cbb\u7652\u3092\u958b\u59cb\u3057\u307e\u3059\u3002\u30de\u30af\u30ed\u30d5\u30a1\u30fc\u30b8\u3084\u4ed6\u306e\u7d30\u80de\u30bf\u30a4\u30d7\u306a\u3069\u306e\u767d\u8840\u7403\u306f\u3001\u672b\u68a2\u5faa\u74b0\u304b\u3089\u640d\u50b7\u90e8\u4f4d\u306b\u52d5\u54e1\u3055\u308c\u3001\u640d\u50b7\u3057\u305f\u7d30\u80de\u304a\u3088\u3073\u30c7\u30d6\u30ea\u3092\u9664\u53bb\u3057\u3001\u708e\u75c7\u306e\u89e3\u6c7a\u3092\u4fc3\u9032\u3057\u307e\u3059\u3002\u7dda\u7dad\u82bd\u7d30\u80de\u306f\u3001\u7d30\u80de\u5916\u30de\u30c8\u30ea\u30c3\u30af\u30b9\u6c88\u7740\u306b\u5fc5\u8981\u3068\u3055\u308c\u307e\u3059\u3002\u307e\u305f\u3001\u8840\u7ba1\u5185\u76ae\u7d30\u80de\u306f\u3001\u7d44\u7e54\u4fee\u5fa9\u30d7\u30ed\u30bb\u30b9\u306b\u5fc5\u8981\u3068\u3055\u308c\u308b\u8840\u7ba1\u65b0\u751f\u3092\u5a92\u4ecb\u3057\u307e\u3059\u3002\u304c\u3093\u9032\u884c\u306b\u95a2\u3057\u3066\u3001\u514d\u75ab\u7d30\u80de\u306e\u7279\u5b9a\u306e\u96c6\u56e3\u304c\u6297\u816b\u760d\u7279\u6027\u307e\u305f\u306f\u816b\u760d\u5f62\u6210\u4fc3\u9032\u80fd\u3092\u6301\u3064\u3053\u3068\u304c\u6570\u4eba\u306e\u79d1\u5b66\u8005\u306b\u3088\u308a\u660e\u3089\u304b\u306b\u3055\u308c\u3066\u304a\u308a\u3001\u75be\u60a3\u9032\u884c\u306f\u7d30\u80de\u30b5\u30d6\u30bb\u30c3\u30c8\u3068\u53ef\u6eb6\u6027\u30e1\u30c7\u30a3\u30a8\u30fc\u30bf\u30fc\u306e\u30d0\u30e9\u30f3\u30b9\u74b0\u5883\u306b\u4f9d\u5b58\u3059\u308b\u3068\u8003\u3048\u3089\u308c\u3066\u3044\u307e\u3059\u3002\u60aa\u6027\u816b\u760d\u306f\u9ad8\u983b\u5ea6\u3067\u6162\u6027\u7684\u3067\u6301\u7d9a\u3059\u308b\u75c5\u7684\u708e\u75c7\u3092\u4f34\u3046\u3053\u3068\u304c\u591a\u304f\u306e\u6587\u732e\u3067\u5831\u544a\u3055\u308c\u3066\u3044\u307e\u3059<sup>*2\u20134<\/sup>\u3002<\/p>\n<p>\u816b\u760d\u5fae\u5c0f\u74b0\u5883\u306f\u3001\u591a\u69d8\u306a\u7d30\u80de\u30b5\u30d6\u30bb\u30c3\u30c8\u304b\u3089\u69cb\u6210\u3055\u308c\u3066\u3044\u307e\u3059\uff08\u56f33.2\uff09\u3002\u56fa\u5f62\u816b\u760d\u306b\u304a\u3051\u308b\u304c\u3093\u9593\u8cea\u304a\u3088\u3073\u514d\u75ab\u7cfb\u306b\u57fa\u3065\u304f\u30d0\u30a4\u30aa\u30de\u30fc\u30ab\u30fc\u30d7\u30ed\u30d5\u30a1\u30a4\u30eb\u306b\u3064\u3044\u3066\u8abf\u3079\u305f\u6700\u8fd1\u306e\u7814\u7a76\u306b\u304a\u3044\u3066\u3001\u304c\u3093\u6cbb\u7642\u306b\u5bfe\u3059\u308b\u751f\u5b58\u304a\u3088\u3073\/\u307e\u305f\u306f\u53cd\u5fdc\u6027\u3068\u7279\u5b9a\u306e\u7d30\u80de\u96c6\u56e3\u306e\u5272\u5408\u3068\u306e\u9593\u306b\u306f\u6b63\u307e\u305f\u306f\u8ca0\u306e\u76f8\u95a2\u6027\u304c\u3042\u308b\u53ef\u80fd\u6027\u304c\u793a\u3055\u308c\u307e\u3057\u305f\u3002\u4f8b\u3048\u3070\u3001\u30d2\u30c8\u4e73\u304c\u3093\u306e\u8abf\u67fb\u7814\u7a76\u3067\u306f\u3001\u304c\u3093\u9593\u8cea\u95a2\u9023\u7dda\u7dad\u82bd\u7d30\u80de\uff08CAF\uff09\u306f\u3001\u816b\u760d\u5f62\u6210\u5fae\u5c0f\u74b0\u5883\u306b\u5bc4\u4e0e\u3057\u3001\u751f\u5b58\u3068\u8ca0\u306e\u76f8\u95a2\u304c\u3042\u308b\u3053\u3068\u304c\u793a\u3055\u308c\u307e\u3057\u305f\u3002\u3053\u308c\u3089\u306e\u7d30\u80de\u306f\u3001\u30b1\u30e2\u30ab\u30a4\u30f3\u9593\u8cea\u7d30\u80de\u7531\u6765\u56e0\u5b501\uff08SDF-1\u3001\u5225\u540d\uff1aCXCL12\uff09\u3068\u547c\u3070\u308c\u308b\u5f37\u529b\u306a\u30ea\u30f3\u30d1\u7403\u304a\u3088\u3073\u30de\u30af\u30ed\u30d5\u30a1\u30fc\u30b8\u8d70\u5316\u6027\u56e0\u5b50\u3092\u7523\u751f\u3057\u307e\u3059\u3002\u3053\u306e\u30b1\u30e2\u30ab\u30a4\u30f3\u306e\u30b7\u30b0\u30ca\u30eb\u306f\u53d7\u5bb9\u4f53CXCR4\u3092\u4ecb\u3057\u3066\u3001\u816b\u760d\u7d30\u80de\u306e\u5897\u6b96\u3001\u6d78\u6f64\u3001\u304a\u3088\u3073\u816b\u760d\u8840\u7ba1\u65b0\u751f\u3092\u4fc3\u9032\u3057\u307e\u3059<sup>*5\u20137<\/sup>\u3002<img loading=\"lazy\" decoding=\"async\" class=\"size-full wp-image-2921 aligncenter\" src=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/1-13.jpg\" alt=\"\u708e\u75c7\u6027\u816b\u760d\u5fae\u5c0f\u74b0\u5883\u306e\u4ee3\u8868\u7684\u306a\u7d30\u80de\u6210\u5206\" width=\"408\" height=\"611\" \/><\/p>\n<p>\u591a\u7a2e\u591a\u69d8\u306a\u304c\u3093\u306b\u304a\u3044\u3066\u3001\u30de\u30af\u30ed\u30d5\u30a1\u30fc\u30b8\u306e\u5b58\u5728\u306f\u8840\u7ba1\u5bc6\u5ea6\u306e\u5897\u52a0\u304a\u3088\u3073\u4f4e\u3044\u81e8\u5e8a\u6210\u7e3e\u3068\u76f8\u95a2\u3059\u308b\u3053\u3068\u304c\u6570\u591a\u304f\u306e\u7814\u7a76\u3067\u7acb\u8a3c\u3055\u308c\u3066\u3044\u307e\u3059\u3002\u816b\u760d\u95a2\u9023\u30de\u30af\u30ed\u30d5\u30a1\u30fc\u30b8\uff08TAM\uff09\u306e\u5b58\u5728\u306f\u816b\u760d\u5897\u6b96\u3092\u30b5\u30dd\u30fc\u30c8\u3057\u307e\u3059\u3002\u3055\u3089\u306b\u3001\u816b\u760d\u7279\u7570\u7684CD8+ \u7d30\u80de\u50b7\u5bb3\u6027T\u30ea\u30f3\u30d1\u7403\uff08CTL\uff09\u304c\u4f4e\u30ec\u30d9\u30eb\u3067\u3042\u308b\u306e\u306b\u5bfe\u3057\u3001\u30de\u30af\u30ed\u30d5\u30a1\u30fc\u30b8\u304a\u3088\u3073CD4+ T\u7d30\u80de\u304c\u9ad8\u30ec\u30d9\u30eb\u3067\u3042\u308b\u3068\u3044\u3046\u7d30\u80de\u306e\u7279\u5fb4\u306f\u30ea\u30b9\u30af\u30d5\u30ea\u30fc\u306e\u751f\u5b58\u3092\u4f4e\u6e1b\u3055\u305b\u308b\u3053\u3068\u304c\u4e88\u6e2c\u3055\u308c\u307e\u3057\u305f\u3002\u307e\u305f\u3001\u30de\u30a6\u30b9\u30e2\u30c7\u30eb\u3092\u7528\u3044\u305f\u3055\u307e\u3056\u307e\u306a\u7814\u7a76\u306b\u304a\u3044\u3066\u3001\u4e73\u623f\u306eTAM\u3092\u6e1b\u5c11\u3055\u305b\u308b\u64cd\u4f5c\u306b\u3088\u308b\u816b\u760d\u5fae\u5c0f\u74b0\u5883\u306e\u5909\u5316\u306f\u3001\u708e\u75c7\u3092\u4fc3\u9032\u3057\u3001\u6bba\u816b\u760d\u6d3b\u6027\u3092\u963b\u5bb3\u3059\u308b\u3053\u3068\u3067\u3001\u5316\u5b66\u7642\u6cd5\u306b\u5bfe\u3059\u308b\u53cd\u5fdc\u6027\u3092\u5897\u5f37\u3057\u3001\u816b\u760d\u7279\u7570\u7684CTL\u306e\u6a5f\u80fd\u3092\u9ad8\u3081\u308b\u53ef\u80fd\u6027\u304c\u3042\u308b\u3053\u3068\u304c\u793a\u3055\u308c\u3066\u3044\u307e\u3059<sup>*5<\/sup>\u3002<\/p>\n<h4>CD4+ T\u7d30\u80de\u30b5\u30d6\u30bb\u30c3\u30c8<\/h4>\n<p>\u56fa\u5f62\u816b\u760d\u306e\u4e2d\u306b\u306f\u3001\u3044\u304f\u3064\u304b\u306e\u30bf\u30a4\u30d7\u306eT\u7d30\u80de\u30b5\u30d6\u30bb\u30c3\u30c8\u304c\u5b58\u5728\u3057\u307e\u3059\uff08\u56f33.3\uff09\u3002Th1\u304a\u3088\u3073Th2\u30b5\u30d6\u30bb\u30c3\u30c8\u306f\u3001\u6700\u521d\u306b\u540c\u5b9a\u3055\u308c\u3001\u5e83\u304f\u7279\u6027\u6c7a\u5b9a\u3055\u308c\u307e\u3057\u305f\u3002Th1\u7d30\u80de\u7cfb\u7d71\u306f\u8ee2\u5199\u56e0\u5b50T-bet\u306b\u3088\u3063\u3066\u5236\u5fa1\u3055\u308c\u3066\u3044\u308b\u306e\u306b\u5bfe\u3057\u3001Th2\u7d30\u80de\u5206\u5316\u306b\u306fGATA-3\u304c\u5f71\u97ff\u3092\u53ca\u307c\u3057\u307e\u3059\u3002CD4+ T\u30d8\u30eb\u30d1\u30fc1\uff08Th1\uff09\u7d30\u80de\u306f\u3001\u816b\u760d\u8840\u7ba1\u65b0\u751f\u3092\u6291\u5236\u3057\u3001\u6297\u539f\u63d0\u793a\u7d30\u80de\uff08APC\uff09\u304a\u3088\u3073NK\u7d30\u80de\u306e\u52d5\u54e1\u3092\u4ecb\u3059\u308b\u6297\u816b\u760d\u7279\u6027\u3092\u6301\u3061\u3001\u30a4\u30f3\u30bf\u30fc\u30ed\u30a4\u30ad\u30f3-2\uff08IL-2\uff09\u3084\u30a4\u30f3\u30bf\u30fc\u30d5\u30a7\u30ed\u30f3\u03b3\uff08IFN-\u03b3\uff09\u306a\u3069\u306e\u30b5\u30a4\u30c8\u30ab\u30a4\u30f3\u3092\u7523\u751f\u3059\u308b\u3053\u3068\u306b\u3088\u3063\u3066CD8+\u7d30\u80de\u306e\u6a5f\u80fd\u3092\u30b5\u30dd\u30fc\u30c8\u3057\u307e\u3059\u3002\u4e00\u822c\u7684\u306b\u3001Th2\u7d30\u80de\u306f\u6bba\u816b\u760d\u6027\u597d\u9178\u7403\u3092\u52d5\u54e1\u3059\u308bIL-4\u304a\u3088\u3073IL-13\u0336\u30b5\u30a4\u30c8\u30ab\u30a4\u30f3\u3092\u7523\u751f\u3059\u308b\u3053\u3068\u306b\u3088\u3063\u3066\u6297\u816b\u760d\u53cd\u5fdc\u306b\u5bc4\u4e0e\u3057\u307e\u3059\u3002\u9006\u306b\u3001Th2\u306f\u3001IL-5\u306e\u5206\u6ccc\u3092\u4ecb\u3057\u3066\u816b\u760d\u9032\u884c\u3092\u4fc3\u9032\u3059\u308b\u3068\u3055\u308c\u307e\u3059\u3002Th17\u7d30\u80de\u306f\u3001\u6297\u83cc\u6027\u7d44\u7e54\u708e\u75c7\u306b\u95a2\u4e0e\u3059\u308bIL-17\u3001IL-21\u304a\u3088\u3073IL-22\u3092\u7523\u751f\u3057\u3001\u591a\u304f\u306e\u304c\u3093\u306b\u304a\u3051\u308b\u816b\u760d\u306e\u6210\u9577\u304a\u3088\u3073\u8840\u7ba1\u65b0\u751f\u3092\u30b5\u30dd\u30fc\u30c8\u3059\u308b\u3068\u4e00\u822c\u7684\u306b\u8003\u3048\u3089\u308c\u3066\u3044\u307e\u3059\u3002FOXP3+ CD4+ Treg\u306f\u3001FOXP3\u8ee2\u5199\u56e0\u5b50\u3092\u767a\u73fe\u3057\u3001\u514d\u75ab\u5b66\u7684\u6052\u5e38\u6027\u304a\u3088\u3073\u81ea\u5df1\u5bdb\u5bb9\u306e\u7dad\u6301\u306b\u91cd\u8981\u3068\u3055\u308c\u307e\u3059\u3002<\/p>\n<p>\u5236\u5fa1\u6027T\u7d30\u80de\uff08Treg\uff09\u306f\u3001\u4ed6\u306eT\u7d30\u80de\u30b5\u30d6\u30bb\u30c3\u30c8\u3092\u963b\u5bb3\u3057\u3001\u816b\u760d\u9032\u884c\u306b\u5bdb\u5927\u306a\u95a2\u4e0e\u3092\u3057\u3066\u3044\u308b\u3068\u8003\u3048\u3089\u308c\u307e\u3059\u3002FOXP3\u3092\u4ecb\u3059\u308bT\u30a8\u30d5\u30a7\u30af\u30bf\u30fc\u7d30\u80de\u306eTreg\u3078\u306e\u5206\u5316\u8a98\u5c0e\u306f\u3001\u816b\u760d\u5fae\u5c0f\u74b0\u5883\u5185\u306bTreg\u304c\u591a\u6570\u5b58\u5728\u3059\u308b\u6f5c\u5728\u7684\u306a\u8981\u56e0\u3068\u3057\u3066\u793a\u5506\u3055\u308c\u3066\u3044\u307e\u3059\u3002Treg\u306f\u3001\u4ed6\u306e\u816b\u760d\u304c\u30ea\u30f3\u30d1\u7403\u306b\u6d78\u6f64\u3059\u308b\u6a5f\u80fd\u3092\u6291\u5236\u3057\u307e\u3059\u304c\u3001\u901a\u5e38\u3001\u816b\u760d\u9032\u884c\u306b\u5bdb\u5bb9\u306a\u74b0\u5883\u3092\u4f9b\u7d66\u3057\u3066\u3044\u308b\u3068\u8aac\u660e\u3055\u308c\u307e\u3059\u3002Treg\u306f\u3001IL-10\u3001\u30c8\u30e9\u30f3\u30b9\u30d5\u30a9\u30fc\u30df\u30f3\u30b0\u5897\u6b96\u56e0\u5b50\u03b2\uff08TGF-\u03b2\uff09\u306e\u7523\u751f\u3001\u304a\u3088\u3073\u7d30\u80de\u50b7\u5bb3\u6027T\u30ea\u30f3\u30d1\u7403\u6297\u539f4\uff08CTLA4\uff09\u306e\u95a2\u4e0e\u3092\u4ecb\u3057\u3066\u514d\u75ab\u53cd\u5fdc\u3092\u6291\u5236\u3059\u308b\u3053\u3068\u306b\u3088\u3063\u3066\u3001\u816b\u760d\u7d30\u80de\u3092\u76f4\u63a5\u6bba\u50b7\u3059\u308b\u53ef\u80fd\u6027\u306e\u3042\u308bCD8+T\u7d30\u80de\uff08\u7d30\u80de\u50b7\u5bb3\u6027T\u30ea\u30f3\u30d1\u7403 [CTL]\u3068\u3082\u547c\u3070\u308c\u308b\uff09\u306a\u3069\u306e\u6bba\u816b\u760d\u7d30\u80de\u306b\u3088\u308b\u6297\u539f\u8a8d\u8b58\u304a\u3088\u3073\u816b\u760d\u7d30\u80de\u306e\u30af\u30ea\u30a2\u30e9\u30f3\u30b9\u3092\u6291\u5236\u3057\u307e\u3059<sup>*8,9<\/sup>\u3002<\/p>\n<p><a href=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/1-14.jpg\"><img loading=\"lazy\" decoding=\"async\" class=\"size-full wp-image-2922 aligncenter\" src=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/1-14.jpg\" alt=\"T\u7d30\u80de\u30b5\u30d6\u30bb\u30c3\u30c8\" width=\"401\" height=\"513\" \/><\/a><a href=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/1-42.jpg\"><img loading=\"lazy\" decoding=\"async\" class=\"size-full wp-image-2998 aligncenter\" src=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/1-42.jpg\" alt=\"CD8 Mouse Monoclonal Antibody (3B5)\" width=\"431\" height=\"472\" \/><\/a><\/p>\n<h4>\u30a4\u30e0\u30ce\u30a2\u30c3\u30bb\u30a4\u3092\u4f7f\u7528\u3059\u308bTh1\/Th2\u30b5\u30a4\u30c8\u30ab\u30a4\u30f3\u75d5\u8de1\u306e\u691c\u51fa<\/h4>\n<p>\u9ad8\u54c1\u8cea\u306e\u4e00\u6b21\u6297\u4f53\u304a\u3088\u3073\u4e8c\u6b21\u6297\u4f53\u306e\u5e45\u5e83\u3044\u30e9\u30a4\u30f3\u30a2\u30c3\u30d7\u306b\u52a0\u3048\u3066\u3001\u5f53\u793e\u3067\u306f\u3001\u30b5\u30a4\u30c8\u30ab\u30a4\u30f3\u304a\u3088\u3073\u4ed6\u306e\u76ee\u7684\u306e\u53ef\u6eb6\u6027\u307e\u305f\u306f\u7d30\u80de\u5185\u30bf\u30f3\u30d1\u30af\u8cea\u3092\u691c\u51fa\u3059\u308b\u305f\u3081\u306e\u5e83\u7bc4\u306aELISA\u30ad\u30c3\u30c8\u3092\u63d0\u4f9b\u3057\u3066\u3044\u307e\u3059\u3002\u611f\u5ea6\u3001\u7cbe\u5ea6\u3001\u304a\u3088\u3073\u4e00\u8cab\u6027\u306e\u3042\u308b\u6027\u80fd\u3092\u78ba\u5b9f\u3059\u308b\u305f\u3081\u306b\u3001\u5f53\u793e\u306eELISA\u30ad\u30c3\u30c8\u306f\u3001\u611f\u5ea6\u3001\u7279\u7570\u6027\u3001\u7cbe\u5ea6\u3001\u30ed\u30c3\u30c8\u9593\u306e\u4e00\u8cab\u6027\u3001\u56de\u53ce\u7387\u3001\u304a\u3088\u3073\u5e73\u884c\u6027\u3092\u542b\u3080\u696d\u754c\u57fa\u6e96\u306b\u9069\u5408\u3059\u308b\u3053\u3068\u304c\u8a66\u9a13\u306b\u3088\u3063\u3066\u4fdd\u8a3c\u3055\u308c\u3066\u3044\u307e\u3059\u3002\u8a73\u7d30\u306f\u3001ELISA validation and qualitytesting\uff08ELISA\u306e\u691c\u8a3c\u304a\u3088\u3073\u54c1\u8cea\u691c\u67fb\uff09\u3092\u3054\u89a7\u304f\u3060\u3055\u3044\u3002<img loading=\"lazy\" decoding=\"async\" class=\"size-full wp-image-2923 aligncenter\" src=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/1-15.jpg\" alt=\"\u4ee3\u8868\u7684\u306aTh1\/Th2\u30b5\u30a4\u30c8\u30ab\u30a4\u30f3\u3092\u691c\u51fa\u3059\u308b\u305f\u3081\u306eELISA\u30ad\u30c3\u30c8\" width=\"807\" height=\"374\" \/><a href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/life-science\/antibodies\/immunoassays\/procartaplex-assays-luminex\/procartaplex-immunoassays.html?CID=bid_pca_aup_r04_jp_cp0000_pjt0000_bid00000_0so_blg_op_awa_oc_s00_ab8_Social_LAB\" target=\"_blank\" rel=\"noopener\">\u5f53\u793e\u306e\u30d2\u30c8\u304a\u3088\u3073\u30de\u30a6\u30b9\u30b5\u30a4\u30c8\u30ab\u30a4\u30f3\u306e\u30de\u30eb\u30c1\u30d7\u30ec\u30c3\u30af\u30b9\u89e3\u6790\u7528Luminex\u30ad\u30c3\u30c8\u306f\u3053\u3061\u3089\u3092\u3054\u89a7\u304f\u3060\u3055\u3044\u3002<\/a><\/p>\n<p>\u5f53\u8a18\u4e8b\u306f\u3001\u816b\u760d\u95a2\u9023\u708e\u75c7\u3092\u8a55\u4fa1\u3059\u308b\u305f\u3081\u306e\u6297\u4f53\u30d9\u30fc\u30b9\u306e\u30c4\u30fc\u30eb\u30ac\u30a4\u30c9\u30d6\u30c3\u30af\u304b\u3089\u306e\u629c\u7c8b\u3067\u3059\u3002<br \/>\n\u30ac\u30a4\u30c9\u30d6\u30c3\u30af\u306f\u4e0b\u8a18\u304b\u3089\u7121\u6599\u3067\u30c0\u30a6\u30f3\u30ed\u30fc\u30c9\u9802\u3051\u307e\u3059\u3002<\/p>\n<p><strong><a class=\"btn btn-red\" href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/global\/forms\/antibody-inflammation-tumor-guidebook-form.html?CID=bid_pca_aup_r04_jp_cp0000_pjt0000_bid00000_0so_blg_op_awa_oc_s00_ab8_Social_LAB\" target=\"_blank\" rel=\"noopener\">\u7121\u6599\u30ac\u30a4\u30c9\u30d6\u30c3\u30af\u3092\u30c0\u30a6\u30f3\u30ed\u30fc\u30c9\u3059\u308b<\/a><\/strong><\/p>\n<h4>\u7d30\u80de\u50b7\u5bb3\u6027T\u30ea\u30f3\u30d1\u7403<\/h4>\n<p>T\u7d30\u80de\u306e\u816b\u760d\u5fae\u5c0f\u74b0\u5883\u3078\u306e\u6f0f\u51fa\u3001T\u7d30\u80de\u306e\u8907\u88fd\u3001\u304a\u3088\u3073\u816b\u760d\u5185\u306b\u304a\u3051\u308b\u30af\u30ed\u30fc\u30f3\u6027\u5897\u6b96\u306f\u3001CD8+T\u7d30\u80de\u306e\u6bba\u816b\u760d\u6d3b\u6027\u306b\u5fc5\u8981\u3068\u8003\u3048\u3089\u308c\u307e\u3059\u3002\u6297\u539f\u7279\u7570\u7684CTL\u306f\u3001\u6a19\u7684\u7d30\u80de\u306b\u304a\u3051\u308b\u30a2\u30dd\u30c8\u30fc\u30b7\u30b9\u3092\u8a98\u5c0e\u3059\u308b\u30d1\u30fc\u30d5\u30a9\u30ea\u30f3\u3001\u30b0\u30e9\u30f3\u30b6\u30a4\u30e0\u3001\u304a\u3088\u3073Fas\u30ea\u30ac\u30f3\u30c9<br \/>\n\uff08FasL\uff09\u306a\u3069\u306e\u30bf\u30f3\u30d1\u30af\u8cea\u3092\u7523\u751f\u3057\u307e\u3059\uff08\u56f33.4\uff09\u3002\u816b\u760d\u7d30\u80de\u306e\u514d\u75ab\u56de\u907f\u306b\u306f\u8907\u6570\u306e\u6a5f\u69cb\u304c\u5bc4\u4e0e\u3057\u3066\u3044\u307e\u3059\u3002\u6297\u816b\u760d\u514d\u75ab\u53cd\u5fdc\u3092\u5236\u9650\u3059\u308b\u8981\u56e0\u306e\u4f8b\u3068\u3057\u3066\u306f\u3001\u3053\u308c\u3089\u306b\u9650\u5b9a\u3055\u308c\u307e\u305b\u3093\u304c\u3001\u304c\u3093\u7d30\u80de\u306e\u8fd1\u508d\u304b\u3089\u306e\u30a8\u30d5\u30a7\u30af\u30bf\u30fcT\u7d30\u80de\u306e\u6392\u9664\u3001T\u7d30\u80de\u6570\u306e\u6e1b\u5c11\u3001\u304a\u3088\u3073T\u7d30\u80de\u306e\u304c\u3093\u7d30\u80de\u3092\u8a8d\u8b58\u3057\u6392\u9664\u3059\u308b\u80fd\u529b\u306e\u4f4e\u4e0b\u304c\u6319\u3052\u3089\u308c\u307e\u3059\u300210 \u4f8b\u3048\u3070\u3001\u7279\u5b9a\u306e\u816b\u760d\u95a2\u9023\u30de\u30af\u30ed\u30d5\u30a1\u30fc\u30b8\uff08TAM\uff09\u306f\u3001\u4e00\u3064\u306e\u7406\u7531\u3068\u3057\u3066\u30a8\u30d5\u30a7\u30af\u30bf\u30fcT\u7d30\u80de\u306e\u6a5f\u80fd\u3092\u6291\u5236\u3059\u308b\u6291\u5236\u6027\u30b5\u30a4\u30c8\u30ab\u30a4\u30f3\u306eIL-10\u3092\u5206\u6ccc\u3059\u308b\u3053\u3068\u304b\u3089\u3001\u816b\u760d\u539f\u6027\u3067\u3042\u308b\u3068\u8003\u3048\u3089\u308c\u3066\u3044\u307e\u3059\u3002<img loading=\"lazy\" decoding=\"async\" class=\"size-full wp-image-2924 aligncenter\" src=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/1-16.jpg\" alt=\"\u6d3b\u6027\u5316\u30a8\u30d5\u30a7\u30af\u30bf\u30fcCD8+T\u7d30\u80de\u306f\u7d30\u80de\u6eb6\u89e3\u6027\u9846\u7c92\u3001\u30b0\u30e9\u30f3\u30b6\u30a4\u30e0\u3001\u304a\u3088 \u3073\u30d1\u30fc\u30d5\u30a9\u30ea\u30f3\u3092\u7523\u751f\" width=\"388\" height=\"385\" \/>T\u7d30\u80de\u53cd\u5fdc\u306e\u6291\u5236\u306f\u3001\u3055\u307e\u3056\u307e\u306a\u6291\u5236\u6027\u7d30\u80de\u8868\u9762\u5206\u5b50\u306e\u767a\u73fe\u306b\u3082\u95a2\u4fc2\u3057\u307e\u3059\u3002\u304c\u3093\u7d30\u80de\u3001\u5358\u7403\u3001\u30de\u30af\u30ed\u30d5\u30a1\u30fc\u30b8\u3001\u304a\u3088\u3073\u6a39\u72b6\u7d30\u80de\u306f\u3001\u6d3b\u6027\u5316T\u7d30\u80de\u306b\u3088\u3063\u3066\u767a\u73fe\u3055\u308c\u308bPD-1\u306b\u95a2\u4e0e\u3059\u308b\u30d7\u30ed\u30b0\u30e9\u30e0\u7d30\u80de\u6b7b\u30bf\u30f3\u30d1\u30af\u8cea1\u30ea\u30ac\u30f3\u30c91\uff08PD-1L\uff09\u3092\u767a\u73fe\u3057\u307e\u3059\u3002\u3053\u306e\u76f8\u4e92\u4f5c\u7528\u306f\u3001T\u7d30\u80de\u5897\u6b96\u3001\u30b5\u30a4\u30c8\u30ab\u30a4\u30f3\u7523\u751f\u3001\u304a\u3088\u3073CD8+ T\u7d30\u80de\u306b\u304a\u3051\u308b\u7d30\u80de\u6eb6\u89e3\u6d3b\u6027\u3092\u6291\u5236\u3057\u307e\u3059\u3002\u30c8\u30ea\u30d7\u30c8\u30d5\u30a1\u30f3\u4ee3\u8b1d\u306e\u8abf\u7bc0\u306f\u3001\u816b\u760d\u304c\u514d\u75ab\u7834\u58ca\u3092\u56de\u907f\u3059\u308b\u3082\u3046\u4e00\u3064\u306e\u65b9\u6cd5\u3067\u3059\u3002\u3053\u306e\u5fc5\u9808\u30a2\u30df\u30ce\u9178\u306f\u3001\u816b\u760d\u7d30\u80de\u3001APC\u3001\u304a\u3088\u3073\u9aa8\u9ac4\u7cfb\u7531\u6765\u30b5\u30d7\u30ec\u30c3\u30b5\u30fc\u7d30\u80de\uff08MDSC\uff09\u306b\u304a\u3044\u3066\u767a\u73fe\u3059\u308b\u9175\u7d20\u3067\u3042\u308b\u30a4\u30f3\u30c9\u30fc\u30eb\u30a2\u30df\u30f3-2,3-\u30b8\u30aa\u30ad\u30b7\u30b2\u30ca\u30fc\u30bc\uff08IDO\uff09\u3092\u5fc5\u8981\u3068\u3059\u308b\u30d7\u30ed\u30bb\u30b9\u3092\u4ecb\u3057\u3066\u7570\u5316\u3055\u308c\u307e\u3059\u3002\u30ad\u30cc\u30ec\u30cb\u30f3\u306a\u3069\u306e\u30c8\u30ea\u30d7\u30c8\u30d5\u30a1\u30f3\u5206\u89e3\u7523\u7269\u304a\u3088\u3073\u30c8\u30ea\u30d7\u30c8\u30d5\u30a1\u30f3\u306e\u67af\u6e07\u306b\u3088\u3063\u3066\u751f\u3058\u305f\u3053\u306e\u514d\u75ab\u6291\u5236\u7684\u74b0\u5883\u306f\u3001\u816b\u760d\u6d78\u6f64\u30ea\u30f3\u30d1\u7403\u306b\u30a2\u30cd\u30eb\u30ae\u30fc\u304a\u3088\u3073\u30a2\u30dd\u30c8\u30fc\u30b7\u30b9\u3092\u8a98\u5c0e\u3057\u307e\u3059\u3002\u307e\u305f\u3001IDO\u306f\u30ca\u30a4\u30fc\u30d6T\u7d30\u80de\u306eTreg\u3078\u306e\u5206\u5316\u3092\u4fc3\u9032\u3057\u307e\u3059<sup>*11,12<\/sup>\u3002<\/p>\n<p>\u816b\u760d\u5fae\u5c0f\u74b0\u5883\u5185\u3067\u306f\u3001\u7279\u5b9a\u306e\u30b1\u30e2\u30ab\u30a4\u30f3\u306e\u6d3b\u6027\u3082T\u7d30\u80de\u304a\u3088\u3073\u4ed6\u306e\u7d30\u80de\u30bf\u30a4\u30d7\u306e\u84c4\u7a4d\u306b\u5f71\u97ff\u3092\u53ca\u307c\u3057\u307e\u3059\u3002\u4f8b\u3048\u3070\u3001\u816b\u760d\u5fae\u5c0f\u74b0\u5883\u5185\u3067\u30b1\u30e2\u30ab\u30a4\u30f3\u306f\u7ffb\u8a33\u5f8c\u4fee\u98fe\u3055\u308c\u307e\u3059\u3002\u4e00\u4f8b\u3068\u3057\u3066\u3001CCL2\u3078\u306e\u7a92\u7d20\u306e\u7ffb\u8a33\u5f8c\u4ed8\u52a0\u306b\u3064\u3044\u3066\u8aac\u660e\u3057\u307e\u3059\u3002\u816b\u760d\u8fd1\u508d\u306f\u6d3b\u6027\u9178\u7d20\u7a2e\u304a\u3088\u3073\u6d3b\u6027\u7a92\u7d20\u7a2e\u304c\u8c4a\u5bcc\u3067\u3001CCL2\u306e\u7a92\u7d20\uff08N-CCL2\uff09\u306f\u816b\u760d\u9593\u8cea\u306b\u304a\u3051\u308bT\u7d30\u80de\u306e\u9694\u96e2\u306b\u5bc4\u4e0e\u3057\u307e\u3059\u304c\u3001\u816b\u760d\u5fae\u5c0f\u74b0\u5883\u5185\u306e\u5358\u7403\u306e\u8a98\u5f15\u304a\u3088\u3073\u96c6\u7a4d\u3092\u4fc3\u9032\u3057\u307e\u3059<sup>*13<\/sup>\u3002<\/p>\n<p>\u8108\u7ba1\u69cb\u9020\u306f\u30a8\u30d5\u30a7\u30af\u30bf\u30fcT\u7d30\u80de\u306e\u30a2\u30af\u30bb\u30b9\u3082\u6392\u9664\u3057\u3066\u3044\u308b\u3068\u8003\u3048\u3089\u308c\u307e\u3059\u304c\u3001Treg\u304a\u3088\u3073\u9aa8\u9ac4\u6027\u7d30\u80de\u306e\u901a\u904e\u3092\u53ef\u80fd\u3068\u3057\u307e\u3059\u3002\u3053\u306e\u3053\u3068\u306f\u3001\u5185\u76aeFas\u30ea\u30ac\u30f3\u30c9\uff08FasL\uff09\u306e\u767a\u73fe\u30ec\u30d9\u30eb\u304c\u4e0a\u6607\u3057\u305f\u816b\u760d\u306b\u542b\u307e\u308c\u308bCD8+ T\u7d30\u80de\u306f\u308f\u305a\u304b\u3067\u3059\u304c\u3001Treg\u306f\u8c4a\u5bcc\u3067\u3042\u308a\u3001\u3053\u308c\u306fc-FLIP\u306e\u9ad8\u767a\u73fe\u306b\u3088\u308aFasL\u3092\u4ecb\u3059\u308b\u30a2\u30dd\u30c8\u30fc\u30b7\u30b9\u306b\u5bfe\u3057\u3066\u4fdd\u8b77\u3055\u308c\u3066\u3044\u308b\u3068\u3044\u3046\u89b3\u5bdf\u306b\u3088\u3063\u3066\u652f\u6301\u3055\u308c\u307e\u3059\u3002\u3053\u308c\u3089\u304a\u3088\u3073\u4ed6\u306e\u514d\u75ab\u56de\u907f\u6a5f\u69cb\u306b\u306f\u3001\u514d\u75ab\u7642\u6cd5\u6226\u7565\u306b\u5bfe\u3059\u308b\u91cd\u8981\u306a\u9650\u754c\u304c\u5b58\u5728\u3057\u3066\u304a\u308a\u3001\u305d\u3046\u3067\u306a\u3051\u308c\u3070\u816b\u760d\u7279\u7570\u7684T\u7d30\u80de\u6d3b\u6027\u304c\u4e0a\u6607\u3059\u308b\u306f\u305a\u3068\u8003\u3048\u3089\u308c\u307e\u3059<sup>*12<\/sup>\u3002<\/p>\n<h4>\u30de\u30af\u30ed\u30d5\u30a1\u30fc\u30b8\u304a\u3088\u3073\u304c\u3093\u95a2\u9023\u708e\u75c7<\/h4>\n<p>\u816b\u760d\u6297\u539f\u7279\u7570\u7684CTL\u306f\u3001\u6291\u5236\u6027\u30de\u30af\u30ed\u30d5\u30a1\u30fc\u30b8\u30b5\u30d6\u30bb\u30c3\u30c8\u306e\u5b58\u5728\u3092\u542b\u3080\u591a\u7a2e\u591a\u69d8\u306a\u6a5f\u69cb\u306b\u3088\u3063\u3066\u6291\u5236\u3055\u308c\u307e\u3059\uff08\u56f33.5\uff09\u3002\u30de\u30af\u30ed\u30d5\u30a1\u30fc\u30b8\u30b5\u30d6\u30bb\u30c3\u30c8\u306f\u3001\u816b\u760d\u5fae\u5c0f\u74b0\u5883\u5185\u306e\u5927\u90e8\u5206\u3092\u5360\u3081\u3001\u591a\u304f\u306e\u7570\u306a\u308b\u6a5f\u69cb\u3092\u4ecb\u3057\u3066\u7d44\u7e54\u640d\u50b7\u3001\u6162\u6027\u708e\u75c7\u3001\u304a\u3088\u3073\u816b\u760d\u9032\u884c\u306b\u5bc4\u4e0e\u3057\u307e\u3059\u3002\u4f8b\u3048\u3070\u3001\u9aa8\u9ac4\u7531\u6765\u514d\u75ab\u6291\u5236\u7d30\u80de\uff08MDSC\uff09\u306f\u3001\u30ea\u30f3\u30d1\u5668\u5b98\u306b\u52d5\u54e1\u3055\u308c\u308b\u3068\u3001\u6d3b\u6027\u9178\u7d20\u7a2e\uff08ROS\uff09\u306e\u7523\u751f\u3092\u4e0a\u65b9\u5236\u5fa1\u3057\u307e\u3059\u3002STAT3\u3092\u5a92\u4ecb\u3059\u308b\u6a5f\u69cb\u3092\u4ecb\u3057\u3066\u3001MDSC\u306f\u30a2\u30eb\u30ae\u30ca\u30fc\u30bc1\uff08ARG1\uff09\u6d3b\u6027\u3092\u4e0a\u6607\u3055\u305b\u3001\u4e00\u9178\u5316\u7a92\u7d20\uff08NO\uff09\u30ec\u30d9\u30eb\u3092\u4f4e\u4e0b\u3055\u305b\u307e\u3059\u3002CD8+T\u7d30\u80de\u306b\u5bfe\u3059\u308b\u6297\u539f\u3092\u63d0\u793a\u3059\u308b\u30d7\u30ed\u30bb\u30b9\u306b\u304a\u3044\u3066\u3001\u7279\u5b9a\u306eROS\u3001\u7279\u306b\u30da\u30eb\u30aa\u30ad\u30b7\u30ca\u30a4\u30c8\u30e9\u30a4\u30c8\u306f\u3001MDSC\u306b\u3088\u3063\u3066\u7523\u751f\u3057\u3001T\u7d30\u80de\u306b\u3088\u3063\u3066\u767a\u73fe\u3055\u308c\u308bTCR\u304a\u3088\u3073CD8\u5206\u5b50\u306e\u30cb\u30c8\u30ed\u30b7\u30eb\u5316\u3092\u8a98\u5c0e\u3057\u307e\u3059\u3002\u3053\u308c\u3089\u306e\u30d7\u30ed\u30bb\u30b9\u306f\u540c\u7a2e\u6297\u539f\u306b\u53cd\u5fdc\u3057\u305fT\u7d30\u80de\u306b\u304a\u3044\u3066\u30a2\u30cd\u30eb\u30ae\u30fc\u3092\u8a98\u5c0e\u3057\u307e\u3059\u3002\u4e0a\u65b9\u5236\u5fa1\u3055\u308c\u308bSTAT1\u6d3b\u6027\u306f\u816b\u760d\u90e8\u4f4d\u306b\u904a\u8d70\u3059\u308bMDSC\u3067\u691c\u51fa\u3055\u308c\u3066\u304a\u308a\u3001\u816b\u760d\u90e8\u4f4d\u306b\u304a\u3044\u3066\u9ad8\u30ec\u30d9\u30eb\u306e\u8a98\u5c0e\u578b\u4e00\u9178\u5316\u7a92\u7d20\u5408\u6210\u9175\u7d20\uff08iNOS\uff09\u3001NO\u3001\u304a\u3088\u3073ARG1\u3068\u4f4e\u30ec\u30d9\u30eb\u306eROS\u3092\u7523\u751f\u3057\u307e\u3059\u3002\u3053\u306e\u72b6\u6cc1\u306b\u304a\u3044\u3066\u3001\u6297\u539f\u975e\u7279\u7570\u7684\u306bCD8+T \u7d30\u80de\u6a5f\u80fd\u306eMDSC\u963b\u5bb3\u304c\u751f\u3058\u307e\u3059<sup>*14<\/sup>\u3002<a href=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/1-17.jpg\"><img loading=\"lazy\" decoding=\"async\" class=\"size-full wp-image-2926 aligncenter\" src=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/1-17.jpg\" alt=\"CTL\u306e\u8ca0\u306e\u5236\u5fa1\" width=\"399\" height=\"369\" \/><\/a><\/p>\n<p>STAT\u7d4c\u8def\u304a\u3088\u3073NF-\u03baB\u7d4c\u8def\u3092\u4ecb\u3059\u308b\u8ee2\u5199\u5236\u5fa1\u306f\u3001MDSC\u306e\u514d\u75ab\u6291\u5236\u3092\u4ef2\u4ecb\u3057\u307e\u3059\u3002\u3044\u3063\u305f\u3093\u6d3b\u6027\u5316\u3055\u308c\u308b\u3068\u3001MDSC\u306f\u30a2\u30eb\u30ae\u30ca\u30fc\u30bc1\u3001\u8a98\u5c0e\u578bNOS\uff08NOS2\uff09\u3001IDO\u3001NADPH\u30aa\u30ad\u30b7\u30c0\u30fc\u30bc\u3001\u306a\u3089\u3073\u306b\u7d30\u80de\u50b7\u5bb3\u6027T\u30ea\u30f3\u30d1\u7403\u3001DC\u3001\u304a\u3088\u3073NK\u7d30\u80de\u3092\u6291\u5236\u3059\u308b\u514d\u75ab\u6291\u5236\u6027\u30b5\u30a4\u30c8\u30ab\u30a4\u30f3\u3092\u7523\u751f\u3057\u3001Treg\u306e\u5897\u52a0\u3092\u3082\u305f\u3089\u3057\u307e\u3059\u3002\u816b\u760d\u5fae\u5c0f\u74b0\u5883\u5185\u3067\u306f\u3001MDSC\u304c\u5206\u5316\u3057\u3001\u816b\u760d\u95a2\u9023\u30de\u30af\u30ed\u30d5\u30a1\u30fc\u30b8\uff08TAM\uff09\u3068\u306a\u308a\u307e\u3059\u3002TAM\u306f\u3001\u30a2\u30eb\u30ae\u30ca\u30fc\u30bc1\u307e\u305f\u306fiNOS\u3092\u3001\u540c\u6642\u306b\u3067\u306f\u3042\u308a\u307e\u305b\u3093\u304c\u4e0a\u65b9\u5236\u5fa1\u3057\u307e\u3059\u3002TAM\u306f\u3001\u30a4\u30f3\u30bf\u30fc\u30ed\u30a4\u30ad\u30f3-1\u03b2\/ IL-1\u03b2\u3001IL-6\u3001IL-10\u304a\u3088\u3073\u30c8\u30e9\u30f3\u30b9\u30d5\u30a9\u30fc\u30df\u30f3\u30b0\u5897\u6b96\u56e0\u5b50-\u03b2\uff08TGF-\u03b2\uff09\u306a\u3069\u306e\u6291\u5236\u6027\u30b5\u30a4\u30c8\u30ab\u30a4\u30f3\u306e\u7523\u751f\u3092\u4ecb\u3059\u308b\u975e\u7279\u7570\u7684\u306aT\u7d30\u80de\u306e\u6291\u5236\u306b\u5bc4\u4e0e\u3057\u307e\u3059\u3002M1 TAM\u30b5\u30d6\u30bb\u30c3\u30c8\u306f\u816b\u760d\u7d30\u80de\u50b7\u5bb3\u6027\u306b\u95a2\u9023\u3059\u308b\u306e\u306b\u5bfe\u3057\u3001M2\u30b5\u30d6\u30bb\u30c3\u30c8\u306f\u816b\u760d\u9032\u884c\u306b\u95a2\u4fc2\u3057\u307e\u3059\uff08\u56f33.6\uff09<sup>*15,16<\/sup>\u3002<img loading=\"lazy\" decoding=\"async\" class=\"size-full wp-image-2928 aligncenter\" src=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/1-19.jpg\" alt=\"\u9aa8\u9ac4\u7cfb\u7531\u6765\u30b5\u30d7\u30ec\u30c3\u30b5\u30fc\u7d30\u80de\u30b5\u30d6\u30bb\u30c3\u30c8\" width=\"395\" height=\"383\" \/>\u6297\u4f53\u306f\u3001\u514d\u75ab\u86cd\u5149\u30a4\u30e1\u30fc\u30b8\u30f3\u30b0\u3001\u514d\u75ab\u7d44\u7e54\u5316\u5b66\u3001\u30a6\u30a7\u30b9\u30bf\u30f3\u30d6\u30ed\u30c3\u30c6\u30a3\u30f3\u30b0\u3001ELISA\u3001\u30d5\u30ed\u30fc\u30b5\u30a4\u30c8\u30e1\u30c8\u30ea\u30fc\u3001\u304a\u3088\u3073\u4ed6\u306e\u30a2\u30d7\u30ea\u30b1\u30fc\u30b7\u30e7\u30f3\u3092\u542b\u3080\u8907\u6570\u306e\u30a2\u30d7\u30ea\u30b1\u30fc\u30b7\u30e7\u30f3\u3067\u4f7f\u7528\u3055\u308c\u3066\u3044\u307e\u3059\u3002\u5f53\u793e\u306e\u6297\u4f53\u304c\u512a\u308c\u305f\u5b9f\u9a13\u7d50\u679c\u306e\u9054\u6210\u3092\u53ef\u80fd\u3068\u3059\u308b\u3053\u3068\u306f\u4e16\u754c\u4e2d\u306e\u591a\u304f\u306e\u6587\u732e\u3067\u5b9f\u8a3c\u3055\u308c\u3066\u3044\u307e\u3059\u3002<a href=\"http:\/\/www.thermofisher.com\/jp\/ja\/home\/life-science\/antibodies.html?CID=bid_pca_aup_r04_jp_cp0000_pjt0000_bid00000_0so_blg_op_awa_oc_s00_ab8_Social_LAB\" target=\"_blank\" rel=\"noopener\">\u6297\u4f53\u691c\u7d22\u30c4\u30fc\u30eb\u3067\u3001\u76ee\u7684\u306e\u7814\u7a76\u306b\u9069\u3057\u305f\u6297\u4f53\u3092\u898b\u3064\u3051\u308b\u305f\u3081\u306b\u306f\u3053\u3061\u3089\u3092\u3054\u89a7\u304f\u3060\u3055\u3044\u3002<\/a><\/p>\n<p>\u60aa\u6027\u7d30\u80de\u304a\u3088\u3073\u975e\u5f62\u8cea\u8ee2\u63db\u7d30\u80de\u304b\u3089\u306a\u308b\u304c\u3093\u7d44\u7e54\u306f\u3001\u8907\u96d1\u306a\u816b\u760d\u5fae\u5c0f\u74b0\u5883\u3092\u69cb\u6210\u3057\u307e\u3059\u3002\u816b\u760d\u74b0\u5883\u306b\u306f\u3001\u816b\u760d\u539f\u6027\u3068\u6297\u816b\u760d\u6027\u306e\u4e21\u65b9\u306e\u7279\u6027\u3092\u6301\u3064T\u7d30\u80de\u304a\u3088\u3073\u9aa8\u9ac4\u30b5\u30d6\u30bb\u30c3\u30c8\u306e\u4ed6\u3001\u4ed6\u306e\u6570\u7a2e\u306e\u767d\u8840\u7403\u3001\u9aa8\u9ac4\u7531\u6765\u708e\u75c7\u7d30\u80de\u3001\u8840\u7ba1\u304a\u3088\u3073\u30ea\u30f3\u30d1\u7ba1\u3001\u7dda\u7dad\u82bd\u7d30\u80de\u3001\u306a\u3089\u3073\u306b\u8102\u80aa\u7d30\u80de\u304c\u542b\u307e\u308c\u307e\u3059<sup>*12,17<\/sup>\u3002 \u3055\u307e\u3056\u307e\u306a\u7d30\u80de\u30bf\u30a4\u30d7\u3001\u767a\u73fe\u3055\u308c\u308b\u4ee3\u8868\u7684\u30de\u30fc\u30ab\u30fc\u3001\u304a\u3088\u3073\u3044\u304f\u3064\u304b\u306e\u65e2\u77e5\u306e\u6a5f\u80fd\u306b\u95a2\u3059\u308b\u30a2\u30a6\u30c8\u30e9\u30a4\u30f3\u3092\u88683.2\u306b\u793a\u3057\u307e\u3059\u3002<\/p>\n<p><a href=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/1-20.jpg\"><img loading=\"lazy\" decoding=\"async\" class=\"size-full wp-image-2929 aligncenter\" src=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/1-20.jpg\" alt=\"\u816b\u760d\u5fae\u5c0f\u74b0\u5883\u306e\u767d\u8840\u7403\u306b\u95a2\u9023\u3059\u308b\u5171\u901a\u306e\u7279\u5fb4\" width=\"809\" height=\"524\" \/><\/a><\/p>\n<p>\u30b5\u30a4\u30c8\u30ab\u30a4\u30f3\u306f\u3001\u816b\u760d\u5fae\u5c0f\u74b0\u5883\u306b\u304a\u3051\u308b\u7d30\u80de\u9593\u30b3\u30df\u30e5\u30cb\u30b1\u30fc\u30b7\u30e7\u30f3\u3092\u5a92\u4ecb\u3059\u308b\u4f4e\u5206\u5b50\u91cf\u30bf\u30f3\u30d1\u30af\u8cea\u3067\u3059\u3002\u30de\u30af\u30ed\u30d5\u30a1\u30fc\u30b8\u304a\u3088\u3073\u30ea\u30f3\u30d1\u7403\u306a\u3069\u306e\u514d\u75ab\u7d30\u80de\u3001\u306a\u3089\u3073\u306b\u7dda\u7dad\u82bd\u7d30\u80de\u304a\u3088\u3073\u5185\u76ae\u7d30\u80de\u306a\u3069\u306e\u9593\u8cea\u7d30\u80de\u306f\u3001\u7d30\u80de\u5206\u5316\u3001\u6210\u9577\u3001\u751f\u5b58\u3001\u904a\u8d70\u3001\u304a\u3088\u3073\u514d\u75ab\u7d30\u80de\u6d3b\u6027\u5316\u306b\u95a2\u4e0e\u3059\u308b\u30b5\u30a4\u30c8\u30ab\u30a4\u30f3\u3092\u653e\u51fa\u3057\u307e\u3059\u3002\u30b5\u30a4\u30c8\u30ab\u30a4\u30f3\u306f\u3001\u6297\u816b\u760d\u6d3b\u6027\u304b\u3089\u7d30\u80de\u5f62\u8cea\u8ee2\u63db\u304a\u3088\u3073\u60aa\u6027\u816b\u760d\u306e\u8a98\u5c0e\u306b\u81f3\u308b\u307e\u3067\u3001\u304c\u3093\u7d30\u80de\u306b\u5e45\u5e83\u3044\u5f71\u97ff\u3092\u4e0e\u3048\u307e\u3059\u3002\u30b5\u30a4\u30c8\u30ab\u30a4\u30f3\u6d3b\u6027\u306e\u6700\u7d42\u7d50\u679c\u306f\u3001\u708e\u75c7\u8a98\u767a\u6027\u304a\u3088\u3073\u6297\u708e\u75c7\u6027\u306e\u30b5\u30a4\u30c8\u30ab\u30a4\u30f3\u306e\u30d0\u30e9\u30f3\u30b9\u3001\u30b5\u30a4\u30c8\u30ab\u30a4\u30f3\u53d7\u5bb9\u4f53\u306e\u767a\u73fe\u3001\u306a\u3089\u3073\u306b\u816b\u760d\u5fae\u5c0f\u74b0\u5883\u306e\u7d30\u80de\u69cb\u6210\u306b\u4f9d\u5b58\u3057\u307e\u3059<sup>*18<\/sup>\u3002 \u816b\u760d\u95a2\u9023\u708e\u75c7\u306e\u62e1\u5927\u306b\u4e00\u822c\u7684\u306b\u95a2\u4e0e\u3059\u308b\u30b5\u30a4\u30c8\u30ab\u30a4\u30f3\u3001\u30b1\u30e2\u30ab\u30a4\u30f3\u3001\u304a\u3088\u3073\u6210\u9577\u56e0\u5b50\u306e\u91cd\u8981\u306a\u7279\u5fb4\u3092\u88683.3\u306b\u793a\u3057\u307e\u3059\u3002<\/p>\n<p><a href=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/1-21.jpg\"><img loading=\"lazy\" decoding=\"async\" class=\"size-full wp-image-2930 aligncenter\" src=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/1-21.jpg\" alt=\"\u816b\u760d\u5fae\u5c0f\u74b0\u5883\u306e\u767d\u8840\u7403\u306b\u95a2\u9023\u3059\u308b\u30bf\u30f3\u30d1\u30af\u8cea\" width=\"811\" height=\"404\" \/><\/a><\/p>\n<h4>\u816b\u760d\u6210\u9577\u3092\u6291\u5236\u3059\u308b\u514d\u75ab\u8abf\u7bc0\u5264<\/h4>\n<p>\u904e\u53bb10\u5e74\u306e\u9593\u3001\u7814\u7a76\u8005\u305f\u3061\u306f\u3001\u514d\u75ab\u7cfb\u306e\u6297\u816b\u760d\u6d3b\u6027\u306e\u5229\u7528\u3092\u76ee\u7684\u3068\u3057\u305f\u6570\u591a\u304f\u306e\u6cbb\u7642\u30a2\u30d7\u30ed\u30fc\u30c1\u3092\u8003\u6848\u3057\u3066\u304d\u307e\u3057\u305f\u3002\u4f8b\u3048\u3070\u3001\u3055\u307e\u3056\u307e\u306a\u304c\u3093\u306b\u5bfe\u3059\u308b\u6cbb\u7642\u7528\u304a\u3088\u3073\u4e88\u9632\u7528\u30ef\u30af\u30c1\u30f3\u306e\u6210\u529f\u306e\u53ef\u80fd\u6027\u306b\u3064\u3044\u3066\u5e45\u5e83\u304f\u8a66\u9a13\u3055\u308c\u3066\u3044\u307e\u3059\u3002IL-2\u306a\u3069\u306e\u30b5\u30a4\u30c8\u30ab\u30a4\u30f3\u306f\u30e1\u30e9\u30ce\u30fc\u30de\u304a\u3088\u3073\u4ed6\u306e\u304c\u3093\u306b\u5bfe\u3059\u308b\u514d\u75ab\u53cd\u5fdc\u3092\u5897\u5f37\u3059\u308b\u305f\u3081\u306b\u51e6\u65b9\u3055\u308c\u3066\u304a\u308a\u3001\u81ea\u5df1\u990a\u5b50CD8+T\u7d30\u80de\u7642\u6cd5\u306b\u3064\u3044\u3066\u8a55\u4fa1\u3059\u308b\u305f\u3081\u306e\u8907\u6570\u306e\u81e8\u5e8a\u8a66\u9a13\u304c\u9032\u884c\u4e2d\u3067\u3001\u5206\u5b50\u6a19\u7684T\u7d30\u80de\u7642\u6cd5\u3092\u63a1\u7528\u3059\u308b\u5b9f\u73fe\u53ef\u80fd\u6027\u306b\u3064\u3044\u3066\u8a55\u4fa1\u3059\u308b\u3053\u3068\u306f\u7814\u7a76\u306e\u6d3b\u52d5\u7684\u306a\u9818\u57df\u3068\u306a\u3063\u3066\u3044\u307e\u3059<sup>*19\u201321<\/sup>\u3002<\/p>\n<p>T\u7d30\u80de\u306f\u5e45\u5e83\u3044\u5171\u523a\u6fc0\u53d7\u5bb9\u4f53\u3092\u767a\u73fe\u3057\u307e\u3059\uff08\u56f33.7\uff09\u3002T\u7d30\u80de\u6d3b\u6027\u5316\u3092\u6c7a\u5b9a\u3059\u308b\u7279\u7570\u7684\u306a\u5236\u5fa1\u6a5f\u69cb\u306b\u3064\u3044\u3066\u6df1\u304f\u7406\u89e3\u3059\u308b\u3053\u3068\u304c\u3001\u514d\u75ab\u6291\u5236\u3092\u963b\u5bb3\u3057\u3001T\u7d30\u80de\u3092\u4ecb\u3059\u308b\u6297\u816b\u760d\u6d3b\u6027\u3092\u5897\u5f37\u3059\u308b\u514d\u75ab\u7642\u6cd5\u7528\u6297\u4f53\u306e\u8fd1\u5e74\u306e\u958b\u767a\u306b\u3064\u306a\u304c\u3063\u3066\u3044\u307e\u3059\u30022\u3064\u306e\u65b0\u898f\u85ac\u5264\u304c\u304c\u3093\u6cbb\u7642\u306b\u65b0\u3057\u3044\u30d1\u30e9\u30c0\u30a4\u30e0\u3092\u3082\u305f\u3089\u3057\u307e\u3057\u305f\u3002\u8fd1\u5e74\u3001\u30c1\u30a7\u30c3\u30af\u30dd\u30a4\u30f3\u30c8\u30bf\u30f3\u30d1\u30af\u306e\u8ceaCTLA-4\u304a\u3088\u3073PD-1\u306e\u963b\u5bb3\u5264\u304c\u30e1\u30e9\u30ce\u30fc\u30de\u304a\u3088\u3073\u975e\u5c0f\u7d30\u80de\u80ba\u304c\u3093\uff08NSCLC\uff09\u306e\u6cbb\u7642\u85ac\u3068\u3057\u3066FDA\u306b\u627f\u8a8d\u3055\u308c\u307e\u3057\u305f\uff08\u88683.4\uff09<sup>*22\u201324<\/sup>\u3002<\/p>\n<p><a href=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/1-22.jpg\"><img loading=\"lazy\" decoding=\"async\" class=\"size-full wp-image-2931 aligncenter\" src=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/1-22.jpg\" alt=\"T\u7d30\u80de\u306e\u5171\u523a\u6fc0\u5206\u5b50\u304a\u3088\u3073\u5171\u6291\u5236\u5206\u5b50\u306a\u3089\u3073\u306b\u305d\u308c\u3089\u306b\u5bfe\u5fdc\u3059\u308b\u30ea\u30ac\u30f3\u30c9\" width=\"400\" height=\"374\" \/><\/a><\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"size-full wp-image-2933 aligncenter\" src=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/1-24.jpg\" alt=\"\u304c\u3093\u6cbb\u7642\u85ac\u3068\u3057\u3066FDA\u306b\u627f\u8a8d\u3055\u308c\u305f\u30c1\u30a7\u30c3\u30af\u30dd\u30a4\u30f3\u30c8\u963b\u5bb3\u5264\" width=\"806\" height=\"249\" \/><a href=\"http:\/\/www.thermofisher.com\/jp\/ja\/home\/life-science\/antibodies.html?CID=bid_pca_aup_r04_jp_cp0000_pjt0000_bid00000_0so_blg_op_awa_oc_s00_ab8_Social_LAB\" target=\"_blank\" rel=\"noopener\">\u8a73\u7d30\u306f\u3053\u3061\u3089\u3092\u3054\u89a7\u304f\u3060\u3055\u3044\u3002<\/a><\/p>\n<h2>\u3010\u7121\u6599\u30c0\u30a6\u30f3\u30ed\u30fc\u30c9\u3011\u816b\u760d\u95a2\u9023\u708e\u75c7\u3092\u8a55\u4fa1\u3059\u308b\u305f\u3081\u306e\u6297\u4f53\u30d9\u30fc\u30b9\u306e\u30c4\u30fc\u30eb<\/h2>\n<p>\u5f53\u8a18\u4e8b\u306f\u3001\u816b\u760d\u95a2\u9023\u708e\u75c7\u3092\u8a55\u4fa1\u3059\u308b\u305f\u3081\u306e\u6297\u4f53\u30d9\u30fc\u30b9\u306e\u30c4\u30fc\u30eb\u30ac\u30a4\u30c9\u30d6\u30c3\u30af\u304b\u3089\u306e\u629c\u7c8b\u3067\u3059\u3002\u4ee5\u4e0b\u306e\u5185\u5bb9\u3092\u542b\u3080PDF\u306f\u4e0b\u8a18\u304b\u3089\u7121\u6599\u3067\u30c0\u30a6\u30f3\u30ed\u30fc\u30c9\u9802\u3051\u307e\u3059\u3002<\/p>\n<ol>\n<li>\u6162\u6027\u708e\u75c7\u304a\u3088\u3073\u304c\u3093<\/li>\n<li>\u304c\u3093\u30c9\u30e9\u30a4\u30d0\u30fc\u907a\u4f1d\u5b50\u304a\u3088\u3073\u708e\u75c7<\/li>\n<li>\u816b\u760d\u5fae\u5c0f\u74b0\u5883<\/li>\n<li>\u30b7\u30b0\u30ca\u30eb\u4f1d\u9054\u304a\u3088\u3073\u816b\u760d\u95a2\u9023\u708e\u75c7<\/li>\n<li>\u8981\u7d04\u304a\u3088\u3073\u4ed8\u9332<\/li>\n<\/ol>\n<p><strong><a class=\"btn btn-red\" href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/global\/forms\/antibody-inflammation-tumor-guidebook-form.html?CID=bid_pca_aup_r04_jp_cp0000_pjt0000_bid00000_0so_blg_op_awa_oc_s00_ab8_Social_LAB\" target=\"_blank\" rel=\"noopener\">\u7121\u6599\u30ac\u30a4\u30c9\u30d6\u30c3\u30af\u3092\u30c0\u30a6\u30f3\u30ed\u30fc\u30c9\u3059\u308b<\/a><\/strong><\/p>\n<h2>\u3010\u7121\u6599\u30c0\u30a6\u30f3\u30ed\u30fc\u30c9\u3011\u304c\u3093\u7814\u7a76\u3092\u4fc3\u9032\u3055\u305b\u308b\u907a\u4f1d\u5b50\u89e3\u6790\u6280\u8853\u30cf\u30f3\u30c9\u30d6\u30c3\u30af<\/h2>\n<p>\u307e\u305f\u3001\u8907\u6570\u306e\u304c\u3093\u7814\u7a76\u9818\u57df\u306b\u304a\u3051\u308b\u8208\u5473\u6df1\u3044\u6700\u65b0\u306e\u767a\u898b\u3092\u53ef\u80fd\u306b\u3059\u308b\u907a\u4f1d\u5b50\u89e3\u6790\u6280\u8853\u3092\u7d39\u4ecb\u3059\u308b\u30cf\u30f3\u30c9\u30d6\u30c3\u30af\u3082\u914d\u5e03\u3057\u3066\u3044\u307e\u3059\u3002\u4f75\u305b\u3066\u3054\u3089\u3093\u304f\u3060\u3055\u3044\u3002<\/p>\n<p><a class=\"btn btn-red\" href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/global\/forms\/cancer-genetic-tech-ebook-download.html?CID=bid_pca_aup_r04_jp_cp0000_pjt0000_bid00000_0so_blg_op_awa_oc_s00_ab8_Social_LAB\" target=\"_blank\" rel=\"noopener\">\u7121\u6599\u30cf\u30f3\u30c9\u30d6\u30c3\u30af\u3092\u30c0\u30a6\u30f3\u30ed\u30fc\u30c9\u3059\u308b<\/a><\/p>\n<p><span style=\"font-size: 8pt\">\u53c2\u8003\u6587\u732e\uff1a<br \/>\n1. Balkwill F, Mantovani A (2001) Inflammation and cancer: back to Virchow? Lancet 357(9255):539\u2013545.<br \/>\n2. Medzhitov R (2008) Origin and physiological roles of inflammation. Nature\u00a0454(7203):428\u2013435.<br \/>\n3. Coussens LM, Werb Z (2002) Inflammation and cancer. Nature 420(6917):860\u2013867.<br \/>\n4. Shiao SL, Ganesan AP, Rugo HS et al. (2011) Immune microenvironments in\u00a0solid tumors: new targets for therapy. Genes Dev 25(24):2559\u20132572.<br \/>\n5. Gajewski TF, Schreiber H, Fu YX (2013) Innate and adaptive immune cells in the\u00a0tumor microenvironment. Nature Immunol 10:1014\u20131022.<br \/>\n6. DeNardo DG, Brennan DJ, Rexhepaj E et al. (2011) Leukocyte complexity\u00a0predicts breast cancer survival and functionally regulates response to\u00a0chemotherapy. Cancer Discov 1(1):54\u201367.<br \/>\n7. Yang L, Karin M (2014) Roles of tumor suppressors in regulating tumorassociated\u00a0inflammation. Cell Death Differ 21(11):1677\u20131686.<br \/>\n8. Kim HJ, Cantor H (2014) CD4 T-Cell Subsets and Tumor Immunity: The Helpful\u00a0and the not-so-helpful. Cancer Immunol Res 2(2):91\u201398.<br \/>\n9. Anestakis D, Petanidis S, Kalyvas S et al. (2015) Mechanisms and applications\u00a0of interleukins in cancer immunotherapy. Int J Mol Sci 16(1):1691\u20131710.<br \/>\n10. Spranger S, Koblish HK, Horton B et al. (2014) Mechanism of tumor rejection\u00a0with doublets of CTLA-4, PD-1\/PD-L1, or IDO blockade involves restored\u00a0IL-2 production and proliferation of CD8(+) T cells directly within the tumor\u00a0microenvironment. Immuno Ther Cancer 2:3.<br \/>\n11. Platten M, Wick W, Van den Eynde BJ (2012) Tryptophan catabolism in cancer:\u00a0beyond IDO and tryptophan depletion. Cancer Res 72(21):5435\u20135440.<br \/>\n12. Joyce JA, Fearon DT (2015) T cell exclusion, immune privilege, and the tumormicroenvironment. Science 348(6230): 74\u201380.<br \/>\n13. Molon B, Ugel S, Del Pozzo F et al. (2011) Chemokine nitration prevents\u00a0intratumoral infiltration of antigen-specific T cell. JEM 208(10):1949\u201362.<br \/>\n14. Gabrilovich DI, Nagaraj S (2009) Myeloid-derived suppressor cells as regulators\u00a0of the immune system. Nat Rev Immunol 9(3):162\u2013174.<br \/>\n15. Sharda DR, Yu S, Ray M et al. (2011) Regulation of macrophage arginase\u00a0expression and tumor growth by the Ron receptor tyrosine kinase. J Immunol\u00a0187(5):2181\u20132192.<br \/>\n16. Allavena P, Sica A, Solinas G, et al. (2008) The inflammatory micro-environment\u00a0in tumor progression: the role of the tumor-associated macrophages. Crit Rev\u00a0Oncol Hematol 66(1):1\u20139.<br \/>\n17. Balkwill FR, Capasso M, Hagemann T (2012) The tumor microenvironment. Cell\u00a0Science 125(Pt 23):5591\u20135596.<br \/>\n18. Landskron G, De la Fuente M, Thuwajit P et al. (2014) Chronic inflammation and\u00a0cytokines in the tumor microenvironment. J Immunol Res 2014:149185.<br \/>\n19. Johns Hopkins Medicine. http:\/\/www.hopkinsmedicine.org\/kimmel_cancer_center\/centers\/breast_cancer_program\/breast_cancer_vaccine.html<br \/>\n20. Cancer Research Institute. (2015) Timeline of progress. http:\/\/www.cancerresearch.org\/our-strategy-impact\/timeline-of-progress\/timeline-detail<br \/>\n21. The Scientist. (2015) The CAR T-cell race. http:\/\/www.the-scientist.com\/?articles.view\/articleNo\/42462\/title\/The-CAR-T-Cell-Race\/<br \/>\n22. Zamarin D, Wolchok JD (2014) Potentiation of immunomodulatory antibodytherapy with oncolytic viruses for treatment of cancer. Mol Ther Oncolytics\u00a01:14004.<br \/>\n23. National Cancer Institute. FDA Approval for Ipilimumab. http:\/\/www.cancer.gov\/about-cancer\/treatment\/drugs\/fda-ipilimumab. Accessed March 2015.<br \/>\n24. FDA News Release. FDA approves Keytruda for advanced non-small cell lungcancer. http:\/\/www.fda.gov\/NewsEvents\/Newsroom\/PressAnnouncements\/ucm465444.htm. Accessed October 2015.<\/span><\/p>\n<p>&nbsp;<\/p>\n<p>\u7814\u7a76\u7528\u306b\u306e\u307f\u4f7f\u7528\u3067\u304d\u307e\u3059\u3002\u8a3a\u65ad\u76ee\u7684\u304a\u3088\u3073\u305d\u306e\u624b\u7d9a\u304d\u4e0a\u3067\u306e\u4f7f\u7528\u306f\u3067\u304d\u307e\u305b\u3093\u3002<\/p>\n","protected":false},"excerpt":{"rendered":"<p>19\u4e16\u7d00\u306b\u3001\u708e\u75c7\u30a4\u30d9\u30f3\u30c8\u3068\u304c\u3093\u9032\u884c\u3068\u306e\u95a2\u9023\u6027\u306b\u95a2\u3059\u308b\u6700\u521d\u306e\u77e5\u898b\u304c\u5831\u544a\u3055\u308c\u307e\u3057\u305f\u3002\u3053\u308c\u3089\u306e\u5148\u306e\u77e5\u898b\u3092\u30b5\u30dd\u30fc\u30c8\u3059\u308b\u75ab\u5b66\u7684\u3001\u5b9f\u9a13\u7684\u3001\u304a\u3088\u3073\u81e8\u5e8a\u7684\u8a3c\u62e0\u3092\u63d0\u4f9b\u3059\u308b\u6570\u591a\u304f\u306e\u5831\u544a\u304c\u5287\u7684\u306b\u5897\u52a0\u3057\u3066\u304d\u3066\u3044\u307e\u3059\u3002\u73fe\u5728\u3001\u304c\u3093\u306e\u767a\u751f\u306b\u304a\u3051\u308b\u30ea\u30b9<\/p>\n","protected":false},"author":988,"featured_media":3757,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_monsterinsights_skip_tracking":false,"_genesis_hide_title":false,"_genesis_hide_breadcrumbs":false,"_genesis_hide_singular_image":false,"_genesis_hide_footer_widgets":false,"_genesis_custom_body_class":"","_genesis_custom_post_class":"","_genesis_layout":"","_jetpack_newsletter_access":"","_jetpack_dont_email_post_to_subs":false,"_jetpack_newsletter_tier_id":0,"_jetpack_memberships_contains_paywalled_content":false,"_jetpack_feature_clip_id":0,"_jetpack_memberships_contains_paid_content":false,"footnotes":"","jetpack_post_was_ever_published":false},"categories":[156],"tags":[83,32],"division":[],"class_list":{"0":"post-900","1":"post","2":"type-post","3":"status-publish","4":"format-standard","5":"has-post-thumbnail","7":"category-mol-bio","8":"tag-cancer","9":"tag-antibody","10":"entry"},"_selected_authors":"","_selected_reviewers":"","acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v27.8 (Yoast SEO v27.8) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>\u3010\u3044\u307e\u3055\u3089\u805e\u3051\u306a\u3044\u304c\u3093\u306e\u57fa\u790e 3\u3011\u304c\u3093\u3068\u5fae\u5c0f\u74b0\u5883\u306e\u95a2\u4fc2\u3068\u306f\uff1f - Learning at the Bench<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/cancer3\/\" \/>\n<meta property=\"og:locale\" content=\"ja_JP\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"\u3010\u3044\u307e\u3055\u3089\u805e\u3051\u306a\u3044\u304c\u3093\u306e\u57fa\u790e 3\u3011\u304c\u3093\u3068\u5fae\u5c0f\u74b0\u5883\u306e\u95a2\u4fc2\u3068\u306f\uff1f\" \/>\n<meta property=\"og:description\" content=\"19\u4e16\u7d00\u306b\u3001\u708e\u75c7\u30a4\u30d9\u30f3\u30c8\u3068\u304c\u3093\u9032\u884c\u3068\u306e\u95a2\u9023\u6027\u306b\u95a2\u3059\u308b\u6700\u521d\u306e\u77e5\u898b\u304c\u5831\u544a\u3055\u308c\u307e\u3057\u305f\u3002\u3053\u308c\u3089\u306e\u5148\u306e\u77e5\u898b\u3092\u30b5\u30dd\u30fc\u30c8\u3059\u308b\u75ab\u5b66\u7684\u3001\u5b9f\u9a13\u7684\u3001\u304a\u3088\u3073\u81e8\u5e8a\u7684\u8a3c\u62e0\u3092\u63d0\u4f9b\u3059\u308b\u6570\u591a\u304f\u306e\u5831\u544a\u304c\u5287\u7684\u306b\u5897\u52a0\u3057\u3066\u304d\u3066\u3044\u307e\u3059\u3002\u73fe\u5728\u3001\u304c\u3093\u306e\u767a\u751f\u306b\u304a\u3051\u308b\u30ea\u30b9\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/cancer3\/\" \/>\n<meta property=\"og:site_name\" content=\"Learning at the Bench\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/ThermoFisherJapan\" \/>\n<meta property=\"article:published_time\" content=\"2018-12-27T00:00:00+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2025-02-28T02:17:52+00:00\" \/>\n<meta property=\"og:image\" content=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/PA049-A1808OB_Handbook-InflammationTumorSuppression_PB_46-1-2.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"900\" \/>\n\t<meta property=\"og:image:height\" content=\"473\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"LATB Staff\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:creator\" content=\"@ThermoFisherJP\" \/>\n<meta name=\"twitter:site\" content=\"@ThermoFisherJP\" \/>\n<meta name=\"twitter:label1\" content=\"\u57f7\u7b46\u8005\" \/>\n\t<meta name=\"twitter:data1\" content=\"LATB Staff\" \/>\n\t<meta name=\"twitter:label2\" content=\"\u63a8\u5b9a\u8aad\u307f\u53d6\u308a\u6642\u9593\" \/>\n\t<meta name=\"twitter:data2\" content=\"28\u5206\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/cancer3\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/cancer3\\\/\"},\"author\":{\"name\":\"LATB Staff\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#\\\/schema\\\/person\\\/00a095a01d54afcdf9457465feb04f7d\"},\"headline\":\"\u3010\u3044\u307e\u3055\u3089\u805e\u3051\u306a\u3044\u304c\u3093\u306e\u57fa\u790e 3\u3011\u304c\u3093\u3068\u5fae\u5c0f\u74b0\u5883\u306e\u95a2\u4fc2\u3068\u306f\uff1f\",\"datePublished\":\"2018-12-27T00:00:00+00:00\",\"dateModified\":\"2025-02-28T02:17:52+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/cancer3\\\/\"},\"wordCount\":613,\"commentCount\":0,\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/cancer3\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2019\\\/07\\\/PA049-A1808OB_Handbook-InflammationTumorSuppression_PB_46-1-2.jpg\",\"keywords\":[\"\u304c\u3093\",\"\u6297\u4f53\"],\"articleSection\":[\"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023\"],\"inLanguage\":\"ja\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/cancer3\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/cancer3\\\/\",\"url\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/cancer3\\\/\",\"name\":\"\u3010\u3044\u307e\u3055\u3089\u805e\u3051\u306a\u3044\u304c\u3093\u306e\u57fa\u790e 3\u3011\u304c\u3093\u3068\u5fae\u5c0f\u74b0\u5883\u306e\u95a2\u4fc2\u3068\u306f\uff1f - Learning at the Bench\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/cancer3\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/cancer3\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2019\\\/07\\\/PA049-A1808OB_Handbook-InflammationTumorSuppression_PB_46-1-2.jpg\",\"datePublished\":\"2018-12-27T00:00:00+00:00\",\"dateModified\":\"2025-02-28T02:17:52+00:00\",\"author\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#\\\/schema\\\/person\\\/00a095a01d54afcdf9457465feb04f7d\"},\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/cancer3\\\/#breadcrumb\"},\"inLanguage\":\"ja\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/cancer3\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"ja\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/cancer3\\\/#primaryimage\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2019\\\/07\\\/PA049-A1808OB_Handbook-InflammationTumorSuppression_PB_46-1-2.jpg\",\"contentUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2019\\\/07\\\/PA049-A1808OB_Handbook-InflammationTumorSuppression_PB_46-1-2.jpg\",\"width\":900,\"height\":473},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/cancer3\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"\u3010\u3044\u307e\u3055\u3089\u805e\u3051\u306a\u3044\u304c\u3093\u306e\u57fa\u790e 3\u3011\u304c\u3093\u3068\u5fae\u5c0f\u74b0\u5883\u306e\u95a2\u4fc2\u3068\u306f\uff1f\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#website\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/\",\"name\":\"Learning at the Bench\",\"description\":\"\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"ja\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#\\\/schema\\\/person\\\/00a095a01d54afcdf9457465feb04f7d\",\"name\":\"LATB Staff\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"ja\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/8803277856c8b753feb4217dff0f9953327452df1a615c3c88b2f9864efb2ddd?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/8803277856c8b753feb4217dff0f9953327452df1a615c3c88b2f9864efb2ddd?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/8803277856c8b753feb4217dff0f9953327452df1a615c3c88b2f9864efb2ddd?s=96&d=mm&r=g\",\"caption\":\"LATB Staff\"},\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/author\\\/latbstaff\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"\u3010\u3044\u307e\u3055\u3089\u805e\u3051\u306a\u3044\u304c\u3093\u306e\u57fa\u790e 3\u3011\u304c\u3093\u3068\u5fae\u5c0f\u74b0\u5883\u306e\u95a2\u4fc2\u3068\u306f\uff1f - Learning at the Bench","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/cancer3\/","og_locale":"ja_JP","og_type":"article","og_title":"\u3010\u3044\u307e\u3055\u3089\u805e\u3051\u306a\u3044\u304c\u3093\u306e\u57fa\u790e 3\u3011\u304c\u3093\u3068\u5fae\u5c0f\u74b0\u5883\u306e\u95a2\u4fc2\u3068\u306f\uff1f","og_description":"19\u4e16\u7d00\u306b\u3001\u708e\u75c7\u30a4\u30d9\u30f3\u30c8\u3068\u304c\u3093\u9032\u884c\u3068\u306e\u95a2\u9023\u6027\u306b\u95a2\u3059\u308b\u6700\u521d\u306e\u77e5\u898b\u304c\u5831\u544a\u3055\u308c\u307e\u3057\u305f\u3002\u3053\u308c\u3089\u306e\u5148\u306e\u77e5\u898b\u3092\u30b5\u30dd\u30fc\u30c8\u3059\u308b\u75ab\u5b66\u7684\u3001\u5b9f\u9a13\u7684\u3001\u304a\u3088\u3073\u81e8\u5e8a\u7684\u8a3c\u62e0\u3092\u63d0\u4f9b\u3059\u308b\u6570\u591a\u304f\u306e\u5831\u544a\u304c\u5287\u7684\u306b\u5897\u52a0\u3057\u3066\u304d\u3066\u3044\u307e\u3059\u3002\u73fe\u5728\u3001\u304c\u3093\u306e\u767a\u751f\u306b\u304a\u3051\u308b\u30ea\u30b9","og_url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/cancer3\/","og_site_name":"Learning at the Bench","article_publisher":"https:\/\/www.facebook.com\/ThermoFisherJapan","article_published_time":"2018-12-27T00:00:00+00:00","article_modified_time":"2025-02-28T02:17:52+00:00","og_image":[{"width":900,"height":473,"url":"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/PA049-A1808OB_Handbook-InflammationTumorSuppression_PB_46-1-2.jpg","type":"image\/jpeg"}],"author":"LATB Staff","twitter_card":"summary_large_image","twitter_creator":"@ThermoFisherJP","twitter_site":"@ThermoFisherJP","twitter_misc":{"\u57f7\u7b46\u8005":"LATB Staff","\u63a8\u5b9a\u8aad\u307f\u53d6\u308a\u6642\u9593":"28\u5206"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/cancer3\/#article","isPartOf":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/cancer3\/"},"author":{"name":"LATB Staff","@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#\/schema\/person\/00a095a01d54afcdf9457465feb04f7d"},"headline":"\u3010\u3044\u307e\u3055\u3089\u805e\u3051\u306a\u3044\u304c\u3093\u306e\u57fa\u790e 3\u3011\u304c\u3093\u3068\u5fae\u5c0f\u74b0\u5883\u306e\u95a2\u4fc2\u3068\u306f\uff1f","datePublished":"2018-12-27T00:00:00+00:00","dateModified":"2025-02-28T02:17:52+00:00","mainEntityOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/cancer3\/"},"wordCount":613,"commentCount":0,"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/cancer3\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/PA049-A1808OB_Handbook-InflammationTumorSuppression_PB_46-1-2.jpg","keywords":["\u304c\u3093","\u6297\u4f53"],"articleSection":["\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023"],"inLanguage":"ja","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/cancer3\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/cancer3\/","url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/cancer3\/","name":"\u3010\u3044\u307e\u3055\u3089\u805e\u3051\u306a\u3044\u304c\u3093\u306e\u57fa\u790e 3\u3011\u304c\u3093\u3068\u5fae\u5c0f\u74b0\u5883\u306e\u95a2\u4fc2\u3068\u306f\uff1f - Learning at the Bench","isPartOf":{"@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/cancer3\/#primaryimage"},"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/cancer3\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/PA049-A1808OB_Handbook-InflammationTumorSuppression_PB_46-1-2.jpg","datePublished":"2018-12-27T00:00:00+00:00","dateModified":"2025-02-28T02:17:52+00:00","author":{"@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#\/schema\/person\/00a095a01d54afcdf9457465feb04f7d"},"breadcrumb":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/cancer3\/#breadcrumb"},"inLanguage":"ja","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/cancer3\/"]}]},{"@type":"ImageObject","inLanguage":"ja","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/cancer3\/#primaryimage","url":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/PA049-A1808OB_Handbook-InflammationTumorSuppression_PB_46-1-2.jpg","contentUrl":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/PA049-A1808OB_Handbook-InflammationTumorSuppression_PB_46-1-2.jpg","width":900,"height":473},{"@type":"BreadcrumbList","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/cancer3\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/"},{"@type":"ListItem","position":2,"name":"\u3010\u3044\u307e\u3055\u3089\u805e\u3051\u306a\u3044\u304c\u3093\u306e\u57fa\u790e 3\u3011\u304c\u3093\u3068\u5fae\u5c0f\u74b0\u5883\u306e\u95a2\u4fc2\u3068\u306f\uff1f"}]},{"@type":"WebSite","@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#website","url":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/","name":"Learning at the Bench","description":"","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"ja"},{"@type":"Person","@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#\/schema\/person\/00a095a01d54afcdf9457465feb04f7d","name":"LATB Staff","image":{"@type":"ImageObject","inLanguage":"ja","@id":"https:\/\/secure.gravatar.com\/avatar\/8803277856c8b753feb4217dff0f9953327452df1a615c3c88b2f9864efb2ddd?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/8803277856c8b753feb4217dff0f9953327452df1a615c3c88b2f9864efb2ddd?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/8803277856c8b753feb4217dff0f9953327452df1a615c3c88b2f9864efb2ddd?s=96&d=mm&r=g","caption":"LATB Staff"},"url":"https:\/\/admin.acceleratingscience.com\/author\/latbstaff\/"}]}},"taxonomy_info":{"category":[{"value":156,"label":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023"}],"post_tag":[{"value":83,"label":"\u304c\u3093"},{"value":32,"label":"\u6297\u4f53"}]},"featured_image_src_large":["https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/PA049-A1808OB_Handbook-InflammationTumorSuppression_PB_46-1-2.jpg",760,399,false],"author_info":{"display_name":"LATB Staff","author_link":"https:\/\/admin.acceleratingscience.com\/author\/latbstaff\/"},"comment_info":0,"category_info":[{"term_id":156,"name":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","slug":"mol-bio","term_group":0,"term_taxonomy_id":156,"taxonomy":"category","description":"","parent":0,"count":538,"filter":"raw","meta":[],"cat_ID":156,"category_count":538,"category_description":"","cat_name":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","category_nicename":"mol-bio","category_parent":0}],"tag_info":[{"term_id":83,"name":"\u304c\u3093","slug":"cancer","term_group":0,"term_taxonomy_id":83,"taxonomy":"post_tag","description":"","parent":0,"count":23,"filter":"raw","meta":[]},{"term_id":32,"name":"\u6297\u4f53","slug":"antibody","term_group":0,"term_taxonomy_id":32,"taxonomy":"post_tag","description":"","parent":0,"count":31,"filter":"raw","meta":[]}],"jetpack-related-posts":[{"id":20124,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/exosome-gene-therapy-ts-r-25015\/","url_meta":{"origin":900,"position":0},"title":"\u3010\u7b2c1\u56de\u3011Exosome\uff08\u30a8\u30af\u30bd\u30bd\u30fc\u30e0\uff0f\u30a8\u30ad\u30bd\u30bd\u30fc\u30e0\uff09\u3068\u306f\uff1f","author":"LatB Staff","date":"2026\u5e744\u670815\u65e5","format":false,"excerpt":"Exosome\uff08\u30a8\u30af\u30bd\u30bd\u30fc\u30e0\uff0f\u30a8\u30ad\u30bd\u30bd\u30fc\u30e0\uff09\u306e\u7814\u7a76\u304c\u6ce8\u76ee\u3092\u96c6\u3081\u3066\u3044\u307e\u3059\u3002\u8208\u5473\u306f\u3042\u3063\u3066\u3082\u3001\u3069\u306e\u3088\u3046\u306b\u7814\u2026","rel":"","context":"\u305d\u306e\u4ed6","block_context":{"text":"\u305d\u306e\u4ed6","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/else\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/03\/6fae859c8c1eacdaa39f3ae843ae1bda-scaled.png?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/03\/6fae859c8c1eacdaa39f3ae843ae1bda-scaled.png?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/03\/6fae859c8c1eacdaa39f3ae843ae1bda-scaled.png?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/03\/6fae859c8c1eacdaa39f3ae843ae1bda-scaled.png?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/03\/6fae859c8c1eacdaa39f3ae843ae1bda-scaled.png?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/03\/6fae859c8c1eacdaa39f3ae843ae1bda-scaled.png?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":25472,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/exosome-ts-r-25067\/","url_meta":{"origin":900,"position":1},"title":"\u3010\u7b2c7\u56de\u3011 \u30a8\u30af\u30bd\u30bd\u30fc\u30e0\u30b5\u30d6\u30bf\u30a4\u30d7\u306e\u5206\u753b\u306e\u6982\u8981","author":"LatB Staff","date":"2026\u5e748\u670813\u65e5","format":false,"excerpt":"\u7d30\u80de\u304c\u5206\u6ccc\u3059\u308b\u7d30\u80de\u5916\u5c0f\u80de\u306e\u4e2d\u3067\u3082\u3001\u30a8\u30af\u30bd\u30bd\u30fc\u30e0\u306f\u305d\u306e\u60c5\u5831\u4f1d\u9054\u6a5f\u80fd\u3084\u75be\u60a3\u3068\u306e\u95a2\u9023\u6027\u304b\u3089\u6ce8\u76ee\u3092\u96c6\u3081\u3066\u3044\u307e\u2026","rel":"","context":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","block_context":{"text":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/mol-bio\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25019_eyecatch.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25019_eyecatch.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25019_eyecatch.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25019_eyecatch.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25019_eyecatch.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25019_eyecatch.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":24545,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/digital-pcr-gene-expression-gsd-ts-sd-25082\/","url_meta":{"origin":900,"position":2},"title":"\u3010Absolute Q\u30c7\u30b8\u30bf\u30ebPCR\u30b7\u30b9\u30c6\u30e0\u306e\u6d3b\u7528\u4f8b\u3011\u30df\u30c8\u30b3\u30f3\u30c9\u30ea\u30a2DNA\u306e\u5b9a\u91cf","author":"LatB Staff","date":"2026\u5e741\u670816\u65e5","format":false,"excerpt":"Applied Biosystems\u2122 QuantStudio\u2122 Absolute Q\u2122 \u30c7\u30b8\u30bf\u30ebP\u2026","rel":"","context":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","block_context":{"text":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/mol-bio\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/12\/digital-pcr-gene-expression-gsd-ts-sd-25082_eyecatch.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/12\/digital-pcr-gene-expression-gsd-ts-sd-25082_eyecatch.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/12\/digital-pcr-gene-expression-gsd-ts-sd-25082_eyecatch.jpg?resize=525%2C300&ssl=1 1.5x"},"classes":[]},{"id":25608,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/cell-culture-basic-cell-culture-bpg-26026\/","url_meta":{"origin":900,"position":3},"title":"\u3010\u7b2c3\u56de\u3011Gibco\u57f9\u5730 60\u5e74\u306e\u30a4\u30ce\u30d9\u30fc\u30b7\u30e7\u30f3\u3002\u7d30\u80de\u57f9\u990a\u306e\u6b74\u53f2\u306f\u57f9\u5730\u306e\u6b74\u53f2\u3002","author":"LatB Staff","date":"2026\u5e7410\u67087\u65e5","format":false,"excerpt":"\u3053\u306e\u30d6\u30ed\u30b0\u3067\u306f\u3001\u30d0\u30a4\u30aa\u30d7\u30ed\u30c0\u30af\u30b7\u30e7\u30f3\u30c1\u30fc\u30e0\u304c\u533b\u85ac\u54c1\u88fd\u9020\u306b\u95a2\u9023\u3059\u308b\u3055\u307e\u3056\u307e\u306a\u30c8\u30d4\u30c3\u30af\u3092\u30b7\u30ea\u30fc\u30ba\u3067\u3054\u7d39\u4ecb\u2026","rel":"","context":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","block_context":{"text":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/mol-bio\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/08\/cell-culture-basic-cell-culture-bpg-26026_eyecatch.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/08\/cell-culture-basic-cell-culture-bpg-26026_eyecatch.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/08\/cell-culture-basic-cell-culture-bpg-26026_eyecatch.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/08\/cell-culture-basic-cell-culture-bpg-26026_eyecatch.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/08\/cell-culture-basic-cell-culture-bpg-26026_eyecatch.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/08\/cell-culture-basic-cell-culture-bpg-26026_eyecatch.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":23098,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/cell-culture-cell-culture-basic-bid-ts-mbr-25059\/","url_meta":{"origin":900,"position":4},"title":"\u7d30\u80de\u57f9\u990a\u7528\u306e\u57f9\u5730\uff5e\u521d\u5fc3\u8005\u5fc5\u898b\uff01\u7d30\u80de\u57f9\u990a\u306e\u5b8c\u5168\u30b5\u30dd\u30fc\u30c8\u30ac\u30a4\u30c9 \u305d\u306e4","author":"LatB Staff","date":"2025\u5e7410\u67082\u65e5","format":false,"excerpt":"\u300c\u7d30\u80de\u57f9\u990a\u306e\u5b8c\u5168\u30b5\u30dd\u30fc\u30c8\u30ac\u30a4\u30c9\u300d\u306f\u3001\u7d30\u80de\u57f9\u990a\u306b\u521d\u3081\u3066\u6311\u6226\u3055\u308c\u308b\u65b9\u3084\u3001\u307e\u3060\u7d4c\u9a13\u306e\u6d45\u3044\u65b9\u306b\u5411\u3051\u3066\u3001\u57fa\u790e\u77e5\u2026","rel":"","context":"\u7d30\u80de\u57f9\u990a\u30fb\u30a4\u30e1\u30fc\u30b8\u30f3\u30b0","block_context":{"text":"\u7d30\u80de\u57f9\u990a\u30fb\u30a4\u30e1\u30fc\u30b8\u30f3\u30b0","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/cell\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/09\/cell-culture-cell-culture-basic-bid-ts-mbr-25059_eycatch.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/09\/cell-culture-cell-culture-basic-bid-ts-mbr-25059_eycatch.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/09\/cell-culture-cell-culture-basic-bid-ts-mbr-25059_eycatch.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/09\/cell-culture-cell-culture-basic-bid-ts-mbr-25059_eycatch.jpg?resize=700%2C400&ssl=1 2x"},"classes":[]},{"id":23457,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/cell-culture-cell-culture-basic-bid-ts-mbr-25063\/","url_meta":{"origin":900,"position":5},"title":"\u7d30\u80de\u57f9\u990a\u7528\u306e\u8840\u6e05\uff08FBS\uff09\u3068\u6297\u751f\u7269\u8cea\u306e\u30dd\u30a4\u30f3\u30c8\uff5e\u7d30\u80de\u57f9\u990a\u306e\u5b8c\u5168\u30b5\u30dd\u30fc\u30c8\u30ac\u30a4\u30c9 \u305d\u306e5","author":"LatB Staff","date":"2025\u5e7410\u670822\u65e5","format":false,"excerpt":"\u300c\u7d30\u80de\u57f9\u990a\u306e\u5b8c\u5168\u30b5\u30dd\u30fc\u30c8\u30ac\u30a4\u30c9\u300d\u306f\u3001\u7d30\u80de\u57f9\u990a\u306b\u521d\u3081\u3066\u6311\u6226\u3059\u308b\u65b9\u3084\u3001\u307e\u3060\u7d4c\u9a13\u306e\u6d45\u3044\u65b9\u306b\u5411\u3051\u3066\u3001\u57fa\u790e\u77e5\u8b58\u2026","rel":"","context":"\u7d30\u80de\u57f9\u990a\u30fb\u30a4\u30e1\u30fc\u30b8\u30f3\u30b0","block_context":{"text":"\u7d30\u80de\u57f9\u990a\u30fb\u30a4\u30e1\u30fc\u30b8\u30f3\u30b0","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/cell\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/10\/cell-culture-cell-culture-basic-bid-ts-mbr-25063_eyecatch-scaled.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/10\/cell-culture-cell-culture-basic-bid-ts-mbr-25063_eyecatch-scaled.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/10\/cell-culture-cell-culture-basic-bid-ts-mbr-25063_eyecatch-scaled.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/10\/cell-culture-cell-culture-basic-bid-ts-mbr-25063_eyecatch-scaled.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/10\/cell-culture-cell-culture-basic-bid-ts-mbr-25063_eyecatch-scaled.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/10\/cell-culture-cell-culture-basic-bid-ts-mbr-25063_eyecatch-scaled.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]}],"jetpack_sharing_enabled":true,"amp_enabled":true,"jetpack_featured_media_url":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/PA049-A1808OB_Handbook-InflammationTumorSuppression_PB_46-1-2.jpg","_links":{"self":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/posts\/900","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/users\/988"}],"replies":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/comments?post=900"}],"version-history":[{"count":0,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/posts\/900\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/media\/3757"}],"wp:attachment":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/media?parent=900"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/categories?post=900"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/tags?post=900"},{"taxonomy":"division","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/division?post=900"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}