{"id":9272,"date":"2021-04-09T16:15:55","date_gmt":"2021-04-09T07:15:55","guid":{"rendered":"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/?p=9272"},"modified":"2022-04-01T10:06:05","modified_gmt":"2022-04-01T01:06:05","slug":"basic_ngs_gsd_mkt_3","status":"publish","type":"post","link":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/basic_ngs_gsd_mkt_3\/","title":{"rendered":"\u6b21\u4e16\u4ee3\u30b7\u30fc\u30b1\u30f3\u30b5 \u30c7\u30fc\u30bf\u89e3\u6790  \u907a\u4f1d\u5b50\u5909\u7570\u89e3\u6790\u306e\u305f\u3081\u306e\u6700\u9069\u306a\u30ab\u30d0\u30ec\u30c3\u30b8"},"content":{"rendered":"<p>\u8fd1\u5e74\u3001\u6b21\u4e16\u4ee3\u30b7\u30fc\u30b1\u30f3\u30b5\uff08NGS\uff09\u3092\u7528\u3044\u305f\u30b2\u30ce\u30e0\u89e3\u6790\u304c\u3055\u307e\u3056\u307e\u306a\u9818\u57df\u3067\u6d3b\u7528\u3055\u308c\u3066\u3044\u307e\u3059\u304c\u3001\u300c\u3044\u307e\u3055\u3089\u805e\u3051\u306a\u3044\u3051\u3069\u3001\u3053\u308c\u3063\u3066\u3069\u3046\u8003\u3048\u305f\u3089\u3044\u3044\u306e\uff1f\u300d\u3068\u60a9\u307e\u308c\u3066\u3044\u308b\u70b9\u306f\u610f\u5916\u3068\u591a\u3044\u306e\u3067\u306f\u306a\u3044\u3067\u3057\u3087\u3046\u304b\u3002NGS\u3092\u4f7f\u7528\u3057\u305f\u89e3\u6790\u306b\u304a\u3044\u3066\u3001\u5b9f\u9a13\u3092\u59cb\u3081\u308b\u524d\u306b\u77e5\u3063\u3066\u304a\u304f\u3079\u304d\u30dd\u30a4\u30f3\u30c8\u304c\u308f\u304b\u3063\u3066\u3044\u308c\u3070\u3001\u5b9f\u9a13\u3084\u30c7\u30fc\u30bf\u89e3\u6790\u306b\u304a\u3051\u308b\u30df\u30b9\u3082\u4f4e\u6e1b\u3055\u305b\u308b\u3053\u3068\u304c\u3067\u304d\u307e\u3059\u3002<\/p>\n<p>\u4eca\u56de\u306f\u3001NGS\u306b\u3088\u308b\u907a\u4f1d\u5b50\u5909\u7570\u89e3\u6790\u306e\u30ab\u30d0\u30ec\u30c3\u30b8\u306e\u8003\u3048\u65b9\u3064\u3044\u3066\u3001\u52d5\u753b\u3067\u8a73\u3057\u304f\u3054\u7d39\u4ecb\u3057\u307e\u3059\u3002\u3053\u308c\u307e\u3067\u306b\u3054\u7d39\u4ecb\u3057\u305f\u57fa\u672c\u539f\u7406\u3084\u624b\u6cd5\u306e\u9078\u629e\u57fa\u6e96\u306a\u3069\u3068\u5408\u308f\u305b\u3066\u3001NGS\u306e\u57fa\u672c\u7684\u306a\u77e5\u8b58\u3092\u7fd2\u5f97\u3057\u3066\u304a\u304d\u307e\u3057\u3087\u3046\u3002<\/p>\n<p>\u25bc\u3053\u3093\u306a\u65b9\u306b\u304a\u3059\u3059\u3081\u3067\u3059\uff01<br \/>\n\u30fbNGS\u521d\u5fc3\u8005<br \/>\n\u30fb\u81ea\u5206\u306e\u76ee\u7684\u306b\u5408\u3063\u305f\u6b21\u4e16\u4ee3\u30b7\u30fc\u30b1\u30f3\u30b5\u306e\u6d3b\u7528\u65b9\u6cd5\u3092\u6a21\u7d22\u3057\u3066\u3044\u308b\u65b9<br \/>\n\u30fb\u6b21\u4e16\u4ee3\u30b7\u30fc\u30b1\u30f3\u30b5\u306e\u51fa\u529b\u3059\u308b\u81a8\u5927\u306a\u30c7\u30fc\u30bf\u306e\u89e3\u6790\u304c\u4e0d\u5b89\u306a\u65b9<\/p>\n<h2>\u30ab\u30d0\u30ec\u30c3\u30b8\u3000- \u91cd\u306a\u308a\u3042\u3046\u30c7\u30fc\u30bf &#8211;<\/h2>\n<p>\u591a\u304f\u306eNGS\u521d\u5fc3\u8005\u306e\u65b9\u304c\u6700\u521d\u306b\u3076\u3064\u304b\u308b\u58c1\u306fNGS\u306e\u30c7\u30fc\u30bf\u89e3\u6790\u3067\u306f\u306a\u3044\u3067\u3057\u3087\u3046\u304b\u3002\u3053\u308c\u306fNGS\u3068\u3044\u3046\u5b9f\u9a13\u7cfb\u304c\u4ed6\u306e\u7cfb\u3068\u7570\u306a\u308a\u3001\u30c7\u30fc\u30bf\u91cf\u304c\u975e\u5e38\u306b\u591a\u3044\u3046\u3048\u306b\u60c5\u5831\u51e6\u7406\u30d7\u30ed\u30bb\u30b9\u3067\u76ee\u306b\u898b\u3048\u306a\u3044\u90e8\u5206\u304c\u591a\u304f\u3001\u30c7\u30fc\u30bf\u304c\u5f97\u3089\u308c\u308b\u30a4\u30e1\u30fc\u30b8\u3092\u6349\u3048\u308b\u3053\u3068\u304c\u96e3\u3057\u3044\u304b\u3089\u3060\u3068\u8003\u3048\u3089\u308c\u307e\u3059\u3002\u3067\u306f\u3001\u3069\u306e\u3088\u3046\u3053\u3068\u306b\u6c17\u3092\u4ed8\u3051\u3066\u89e3\u6790\u306e\u6e96\u5099\u3092\u9032\u3081\u308c\u3070\u3088\u3044\u306e\u3067\u3057\u3087\u3046\u304b\u3002\u30ab\u30d0\u30ec\u30c3\u30b8\u3068\u3044\u3046\u89b3\u70b9\u304b\u3089\u89e3\u8aac\u3057\u307e\u3059\u3002<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignright wp-image-9274 size-full\" src=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2021\/04\/pic1-e1617920392902.png\" alt=\"\" width=\"400\" height=\"246\" \/><\/p>\n<p>NGS\u3067\u306f\u4e00\u822c\u7684\u306b\u3001\u65e2\u77e5\u306e\u907a\u4f1d\u60c5\u5831\u3092\u6301\u3064\u751f\u7269\u3092\u89e3\u6790\u3059\u308b\u5834\u5408\u3001\u3042\u308b\u7a0b\u5ea6\u306e\u9577\u3055\u306e\u914d\u5217\u60c5\u5831\u3092\u53d6\u5f97\u3057\u305f\u5f8c\u3001\u30b2\u30ce\u30e0\u4e0a\u306e\u3069\u306e\u4f4d\u7f6e\u306b\u5bfe\u5fdc\u3059\u308b\u914d\u5217\u304b\u3092\u30ea\u30d5\u30a1\u30ec\u30f3\u30b9\u914d\u5217\u3068\u7167\u5408\u3057\u307e\u3059\uff08\u30de\u30c3\u30d4\u30f3\u30b0\uff09\u3002\u307e\u305f\u3001\u4e00\u5ea6\u306e\u30b7\u30fc\u30b1\u30f3\u30b9\u3067\u81a8\u5927\u306a\u91cf\u306e\u30c7\u30fc\u30bf\u304c\u5f97\u3089\u308c\u308b\u305f\u3081\u3001\u540c\u3058\u30ea\u30d5\u30a1\u30ec\u30f3\u30b9\u914d\u5217\u4e0a\u306e\u30dd\u30b8\u30b7\u30e7\u30f3\u3092\u5225\u3005\u306e\u30b7\u30fc\u30b1\u30f3\u30b9\u30ea\u30fc\u30c9\u304c\u30ab\u30d0\u30fc\u3057\u5408\u3063\u3066\u30b7\u30fc\u30b1\u30f3\u30b9\u3057\u3066\u3044\u308b\u72b6\u614b\u3092\u4f5c\u308a\u51fa\u3059\u3053\u3068\u304c\u3067\u304d\u307e\u3059\u3002\u3057\u305f\u304c\u3063\u3066\u3001\u3053\u308c\u3089\u306e\u30c7\u30fc\u30bf\u306f\u30de\u30c3\u30d4\u30f3\u30b0\u3059\u308b\u3068\u3001\u30ea\u30d5\u30a1\u30ec\u30f3\u30b9\u914d\u5217\u4e0a\u306e\u3055\u307e\u3056\u307e\u306a\u9818\u57df\u306b\u7a4d\u307f\u91cd\u306a\u308b\u3053\u3068\u306b\u306a\u308a\u307e\u3059\u3002\u3053\u306e\u30c7\u30fc\u30bf\u306e\u91cd\u306a\u308a\u3092\u30ab\u30d0\u30ec\u30c3\u30b8\u3068\u547c\u3073\u307e\u3059\u3002\u307e\u305f\u3001\u3053\u306e\u30ab\u30d0\u30ec\u30c3\u30b8\u306e\u539a\u307f\u3092<strong>coverage depth<\/strong>\u3001\u5bfe\u8c61\u306e\u30b2\u30ce\u30e0\u9818\u57df\u4e0a\u306b\u5bfe\u3057\u3066\u306e\u30c7\u30fc\u30bf\u306e\u5747\u4e00\u6027\u3092<strong>uniformity<\/strong>\u3068\u547c\u3073\u307e\u3059\u3002<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignright size-full wp-image-9276\" src=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2021\/04\/pic2-e1617920487394.png\" alt=\"\" width=\"400\" height=\"167\" \/><\/p>\n<p>\u3053\u308c\u3089\u306fNGS\u306e\u30c7\u30fc\u30bf\u306e\u4fe1\u983c\u6027\u306e\u6307\u6a19\u3068\u306a\u308b\u305f\u3081\u3001\u975e\u5e38\u306b\u91cd\u8981\u306a\u9805\u76ee\u3068\u306a\u3063\u3066\u3044\u307e\u3059\u3002\u3057\u304b\u3057\u3001NGS\u3067\u306f\u81a8\u5927\u306a\u91cf\u306e\u30c7\u30fc\u30bf\u304c\u5f97\u3089\u308c\u308b\u3068\u306f\u3044\u3048\u3001\u30b3\u30b9\u30c8\u7b49\u3092\u8003\u3048\u308b\u3068\u30b5\u30f3\u30d7\u30eb\u3042\u305f\u308a\u306e\u30c7\u30fc\u30bf\u91cf\uff08\u9818\u57df\u306e\u9577\u3055\u3001coverage depth\u306a\u3069\uff09\u3092\u9069\u5207\u306b\u8a2d\u5b9a\u3059\u308b\u5fc5\u8981\u304c\u3042\u308a\u3001\u305d\u308c\u3068\u3068\u3082\u306b\u4e00\u5ea6\u306b\u30b7\u30fc\u30b1\u30f3\u30b9\u3067\u304d\u308b\u30b5\u30f3\u30d7\u30eb\u6570\u3092\u6982\u7b97\u3057\u3066\u304a\u304f\u5fc5\u8981\u304c\u3042\u308a\u307e\u3059\u3002<\/p>\n<p>&nbsp;<\/p>\n<p>\u3067\u306f\u3001\u5b9f\u969b\u306b\u3055\u307e\u3056\u307e\u306a\u907a\u4f1d\u5b50\u5909\u7570\u89e3\u6790\u3092\u9032\u3081\u3066\u3044\u304f\u3046\u3048\u3067\u3001\u3053\u308c\u3089\u3092\u3069\u306e\u3088\u3046\u306b\u8a2d\u5b9a\u3057\u3066\u3044\u304f\u5fc5\u8981\u304c\u3042\u308b\u3067\u3057\u3087\u3046\u304b\u3002<\/p>\n<p>\u4e0b\u306e\u52d5\u753b\u3067\u306f\u3001\u30ab\u30d0\u30ec\u30c3\u30b8\u306e\u6982\u5ff5\u3068\u907a\u4f1d\u5b50\u5909\u7570\u89e3\u6790\u306b\u304a\u3051\u308b\u8003\u3048\u65b9\u3092\u307e\u3068\u3081\u3066\u304a\u308a\u307e\u3059\u306e\u3067\u3001\u305c\u3072\u3054\u8996\u8074\u304f\u3060\u3055\u3044\u3002<br \/>\n<iframe loading=\"lazy\" title=\"\u6b21\u4e16\u4ee3\u30b7\u30fc\u30b1\u30f3\u30b9\u7528\u8a9e\u304c\u308f\u304b\u308b\uff01\u5909\u7570\u89e3\u6790\u306e\u305f\u3081\u306e\u6700\u9069\u306a\u30ab\u30d0\u30ec\u30c3\u30b8\" width=\"760\" height=\"428\" src=\"https:\/\/www.youtube.com\/embed\/-wqt0OCR6UA?feature=oembed\" frameborder=\"0\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture\" allowfullscreen><\/iframe><\/p>\n<h2>\u307e\u3068\u3081<\/h2>\n<p>\u30fbNGS\u306b\u304a\u3051\u308b\u30c7\u30fc\u30bf\u306e\u91cd\u306a\u308a\u3092coverage depth\u3001\u5747\u4e00\u6027\u3092uniformity\u3068\u3044\u3046\u3002<br \/>\n\u30fb\u30c7\u30fc\u30bf\u306e\u4fe1\u983c\u6027\u306e\u305f\u3081\u306b\u907a\u4f1d\u5b50\u5909\u7570\u306e\u7a2e\u985e\u306b\u3088\u3063\u3066\u30ab\u30d0\u30ec\u30c3\u30b8\u3092\u8003\u3048\u308b\u5fc5\u8981\u304c\u3042\u308b\u3002<br \/>\n\u30fb\u30b5\u30f3\u30d7\u30eb\u3042\u305f\u308a\u306e\u9069\u5207\u306a\u30ab\u30d0\u30ec\u30c3\u30b8\u3092\u8a2d\u5b9a\u3059\u308c\u3070\u3001\u30b7\u30fc\u30b1\u30f3\u30b9\u3042\u305f\u308a\u306e\u89e3\u6790\u53ef\u80fd\u30b5\u30f3\u30d7\u30eb\u6570\u3082\u8a2d\u5b9a\u3067\u304d\u308b\u3002<\/p>\n<p>NGS\u306e\u57fa\u672c\u7684\u306a\u30c7\u30fc\u30bf\u306e\u53d6\u5f97\u306e\u6d41\u308c\u306f\u3001\u300c<a href=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/basic_ngs_gsd_mkt_1?cid=csd_ngs_sbu_r04_jp_cp1444_pjt7240_csd00000_0so_blg_op_awa_og_s00_ngs32_Social_LAB\" target=\"_blank\" rel=\"noopener\">\u4eca\u3055\u3089\u805e\u3051\u306a\u3044\uff01Ion Torrent\u30b7\u30b9\u30c6\u30e0\u306e\u539f\u7406\u3068\u306f<\/a>\u300d\u3084\u300c<a href=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/basic_ngs_gsd_mkt_2\/?cid=csd_ngs_sbu_r04_jp_cp1444_pjt7240_csd00000_0so_blg_op_awa_og_s00_ngs32_Social_LAB\" target=\"_blank\" rel=\"noopener\">\u77e5\u3063\u3066\u307e\u3059\u304b\uff1f\u5168\u30b2\u30ce\u30e0\u30ea\u30b7\u30fc\u30b1\u30f3\u30b9\u3068\u30bf\u30fc\u30b2\u30c3\u30c8\u30ea\u30b7\u30fc\u30b1\u30f3\u30b9<\/a>\u300d\u306e\u52d5\u753b\u3067\u3082\u7d39\u4ecb\u3057\u3066\u304a\u308a\u307e\u3059\u306e\u3067\u3001\u305c\u3072\u4e00\u5ea6\u3054\u89a7\u304f\u3060\u3055\u3044\u3002<\/p>\n<p>Ion Torrent\u2122 NGS\u3092\u7528\u3044\u305f\u57fa\u672c\u7684\u306a\u539f\u7406\u3084\u30a2\u30d7\u30ea\u30b1\u30fc\u30b7\u30e7\u30f3\u306b\u95a2\u3059\u308b\u60c5\u5831\u306f\u4ee5\u4e0b\u306eURL\u304b\u3089\u78ba\u8a8d\u3044\u305f\u3060\u304f\u3053\u3068\u304c\u3067\u304d\u307e\u3059\u3002<br \/>\n<a href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/life-science\/sequencing\/next-generation-sequencing\/ngs-basics.html?cid=csd_ngs_sbu_r04_jp_cp1444_pjt7240_csd00000_0so_blg_op_awa_og_s00_ngs32_Social_LAB\" target=\"_blank\" rel=\"noopener\">https:\/\/www.thermofisher.com\/jp\/ja\/home\/life-science\/sequencing\/next-generation-sequencing\/ngs-basics.html<\/a><\/p>\n<h2>\u6b21\u4e16\u4ee3\u30b7\u30fc\u30b1\u30f3\u30b9 \u30c7\u30fc\u30bf\u89e3\u6790\u30aa\u30f3\u30e9\u30a4\u30f3\u500b\u5225\u76f8\u8ac7<\/h2>\n<p>IonTorrent\u30e6\u30fc\u30b6\u3067\u30c7\u30fc\u30bf\u89e3\u6790\u306b\u95a2\u3059\u308b\u5177\u4f53\u7684\u306a\u8ab2\u984c\u3092\u304a\u6301\u3061\u306e\u65b9\u306b\u306f\u3001\u7121\u6599\u306e\u500b\u5225\u76f8\u8ac7\u306e\u6642\u9593\u3092\u958b\u8a2d\u3057\u3066\u3044\u307e\u3059\u3002<\/p>\n<p><a class=\"btn btn-red\" href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/technical-resources\/seminars\/ngs-data-analysis-online-consultation.html?cid=csd_ngs_sbu_r04_jp_cp1444_pjt7240_csd00000_0so_blg_op_awa_og_s00_ngs32_Social_LAB\" target=\"_blank\" rel=\"noopener noreferrer\">\u8a73\u7d30\u3092\u898b\u308b<\/a><\/p>\n<p>\u7814\u7a76\u7528\u306b\u306e\u307f\u4f7f\u7528\u3067\u304d\u307e\u3059\u3002\u8a3a\u65ad\u7528\u306b\u306f\u4f7f\u7528\u3044\u305f\u3060\u3051\u307e\u305b\u3093\u3002<\/p>\n","protected":false},"excerpt":{"rendered":"<p>\u8fd1\u5e74\u3001\u6b21\u4e16\u4ee3\u30b7\u30fc\u30b1\u30f3\u30b5\uff08NGS\uff09\u3092\u7528\u3044\u305f\u30b2\u30ce\u30e0\u89e3\u6790\u304c\u3055\u307e\u3056\u307e\u306a\u9818\u57df\u3067\u6d3b\u7528\u3055\u308c\u3066\u3044\u307e\u3059\u304c\u3001\u300c\u3044\u307e\u3055\u3089\u805e\u3051\u306a\u3044\u3051\u3069\u3001\u3053\u308c\u3063\u3066\u3069\u3046\u8003\u3048\u305f\u3089\u3044\u3044\u306e\uff1f\u300d\u3068\u60a9\u307e\u308c\u3066\u3044\u308b\u70b9\u306f\u610f\u5916\u3068\u591a\u3044\u306e\u3067\u306f\u306a\u3044\u3067\u3057\u3087\u3046\u304b\u3002NGS\u3092\u4f7f\u7528\u3057\u305f\u89e3\u6790\u306b\u304a\u3044\u3066<\/p>\n","protected":false},"author":975,"featured_media":9297,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_monsterinsights_skip_tracking":false,"_genesis_hide_title":false,"_genesis_hide_breadcrumbs":false,"_genesis_hide_singular_image":false,"_genesis_hide_footer_widgets":false,"_genesis_custom_body_class":"","_genesis_custom_post_class":"","_genesis_layout":"","_jetpack_newsletter_access":"","_jetpack_dont_email_post_to_subs":false,"_jetpack_newsletter_tier_id":0,"_jetpack_memberships_contains_paywalled_content":false,"_jetpack_feature_clip_id":0,"_jetpack_memberships_contains_paid_content":false,"footnotes":"","jetpack_post_was_ever_published":false},"categories":[156],"tags":[165],"division":[],"class_list":["post-9272","post","type-post","status-publish","format-standard","has-post-thumbnail","category-mol-bio","tag-ngs","entry"],"_selected_authors":"","_selected_reviewers":"","acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v27.8 (Yoast SEO v27.8) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>\u6b21\u4e16\u4ee3\u30b7\u30fc\u30b1\u30f3\u30b5 \u30c7\u30fc\u30bf\u89e3\u6790 \u907a\u4f1d\u5b50\u5909\u7570\u89e3\u6790\u306e\u305f\u3081\u306e\u6700\u9069\u306a\u30ab\u30d0\u30ec\u30c3\u30b8 - Learning at the Bench<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/basic_ngs_gsd_mkt_3\/\" \/>\n<meta property=\"og:locale\" content=\"ja_JP\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"\u6b21\u4e16\u4ee3\u30b7\u30fc\u30b1\u30f3\u30b5 \u30c7\u30fc\u30bf\u89e3\u6790 \u907a\u4f1d\u5b50\u5909\u7570\u89e3\u6790\u306e\u305f\u3081\u306e\u6700\u9069\u306a\u30ab\u30d0\u30ec\u30c3\u30b8\" \/>\n<meta property=\"og:description\" content=\"\u8fd1\u5e74\u3001\u6b21\u4e16\u4ee3\u30b7\u30fc\u30b1\u30f3\u30b5\uff08NGS\uff09\u3092\u7528\u3044\u305f\u30b2\u30ce\u30e0\u89e3\u6790\u304c\u3055\u307e\u3056\u307e\u306a\u9818\u57df\u3067\u6d3b\u7528\u3055\u308c\u3066\u3044\u307e\u3059\u304c\u3001\u300c\u3044\u307e\u3055\u3089\u805e\u3051\u306a\u3044\u3051\u3069\u3001\u3053\u308c\u3063\u3066\u3069\u3046\u8003\u3048\u305f\u3089\u3044\u3044\u306e\uff1f\u300d\u3068\u60a9\u307e\u308c\u3066\u3044\u308b\u70b9\u306f\u610f\u5916\u3068\u591a\u3044\u306e\u3067\u306f\u306a\u3044\u3067\u3057\u3087\u3046\u304b\u3002NGS\u3092\u4f7f\u7528\u3057\u305f\u89e3\u6790\u306b\u304a\u3044\u3066\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/basic_ngs_gsd_mkt_3\/\" \/>\n<meta property=\"og:site_name\" content=\"Learning at the Bench\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/ThermoFisherJapan\" \/>\n<meta property=\"article:published_time\" content=\"2021-04-09T07:15:55+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2022-04-01T01:06:05+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2021\/04\/shutterstock_1536784736-1.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"600\" \/>\n\t<meta property=\"og:image:height\" content=\"300\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"LatB Staff\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:creator\" content=\"@ThermoFisherJP\" \/>\n<meta name=\"twitter:site\" content=\"@ThermoFisherJP\" \/>\n<meta name=\"twitter:label1\" content=\"\u57f7\u7b46\u8005\" \/>\n\t<meta name=\"twitter:data1\" content=\"LatB Staff\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/basic_ngs_gsd_mkt_3\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/basic_ngs_gsd_mkt_3\\\/\"},\"author\":{\"name\":\"LatB Staff\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#\\\/schema\\\/person\\\/bdbe319a2001f279ddce6ab8eaad1253\"},\"headline\":\"\u6b21\u4e16\u4ee3\u30b7\u30fc\u30b1\u30f3\u30b5 \u30c7\u30fc\u30bf\u89e3\u6790 \u907a\u4f1d\u5b50\u5909\u7570\u89e3\u6790\u306e\u305f\u3081\u306e\u6700\u9069\u306a\u30ab\u30d0\u30ec\u30c3\u30b8\",\"datePublished\":\"2021-04-09T07:15:55+00:00\",\"dateModified\":\"2022-04-01T01:06:05+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/basic_ngs_gsd_mkt_3\\\/\"},\"wordCount\":52,\"commentCount\":0,\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/basic_ngs_gsd_mkt_3\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2021\\\/04\\\/shutterstock_1536784736-1.jpg\",\"keywords\":[\"\u6b21\u4e16\u4ee3\u30b7\u30fc\u30b1\u30f3\u30b5\"],\"articleSection\":[\"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023\"],\"inLanguage\":\"ja\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/basic_ngs_gsd_mkt_3\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/basic_ngs_gsd_mkt_3\\\/\",\"url\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/basic_ngs_gsd_mkt_3\\\/\",\"name\":\"\u6b21\u4e16\u4ee3\u30b7\u30fc\u30b1\u30f3\u30b5 \u30c7\u30fc\u30bf\u89e3\u6790 \u907a\u4f1d\u5b50\u5909\u7570\u89e3\u6790\u306e\u305f\u3081\u306e\u6700\u9069\u306a\u30ab\u30d0\u30ec\u30c3\u30b8 - Learning at the Bench\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/basic_ngs_gsd_mkt_3\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/basic_ngs_gsd_mkt_3\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2021\\\/04\\\/shutterstock_1536784736-1.jpg\",\"datePublished\":\"2021-04-09T07:15:55+00:00\",\"dateModified\":\"2022-04-01T01:06:05+00:00\",\"author\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#\\\/schema\\\/person\\\/bdbe319a2001f279ddce6ab8eaad1253\"},\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/basic_ngs_gsd_mkt_3\\\/#breadcrumb\"},\"inLanguage\":\"ja\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/basic_ngs_gsd_mkt_3\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"ja\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/basic_ngs_gsd_mkt_3\\\/#primaryimage\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2021\\\/04\\\/shutterstock_1536784736-1.jpg\",\"contentUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2021\\\/04\\\/shutterstock_1536784736-1.jpg\",\"width\":600,\"height\":300},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/basic_ngs_gsd_mkt_3\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"\u6b21\u4e16\u4ee3\u30b7\u30fc\u30b1\u30f3\u30b5 \u30c7\u30fc\u30bf\u89e3\u6790 \u907a\u4f1d\u5b50\u5909\u7570\u89e3\u6790\u306e\u305f\u3081\u306e\u6700\u9069\u306a\u30ab\u30d0\u30ec\u30c3\u30b8\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#website\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/\",\"name\":\"Learning at the Bench\",\"description\":\"\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"ja\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#\\\/schema\\\/person\\\/bdbe319a2001f279ddce6ab8eaad1253\",\"name\":\"LatB Staff\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"ja\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g\",\"caption\":\"LatB Staff\"},\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/author\\\/lgbadmin\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"\u6b21\u4e16\u4ee3\u30b7\u30fc\u30b1\u30f3\u30b5 \u30c7\u30fc\u30bf\u89e3\u6790 \u907a\u4f1d\u5b50\u5909\u7570\u89e3\u6790\u306e\u305f\u3081\u306e\u6700\u9069\u306a\u30ab\u30d0\u30ec\u30c3\u30b8 - Learning at the Bench","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/basic_ngs_gsd_mkt_3\/","og_locale":"ja_JP","og_type":"article","og_title":"\u6b21\u4e16\u4ee3\u30b7\u30fc\u30b1\u30f3\u30b5 \u30c7\u30fc\u30bf\u89e3\u6790 \u907a\u4f1d\u5b50\u5909\u7570\u89e3\u6790\u306e\u305f\u3081\u306e\u6700\u9069\u306a\u30ab\u30d0\u30ec\u30c3\u30b8","og_description":"\u8fd1\u5e74\u3001\u6b21\u4e16\u4ee3\u30b7\u30fc\u30b1\u30f3\u30b5\uff08NGS\uff09\u3092\u7528\u3044\u305f\u30b2\u30ce\u30e0\u89e3\u6790\u304c\u3055\u307e\u3056\u307e\u306a\u9818\u57df\u3067\u6d3b\u7528\u3055\u308c\u3066\u3044\u307e\u3059\u304c\u3001\u300c\u3044\u307e\u3055\u3089\u805e\u3051\u306a\u3044\u3051\u3069\u3001\u3053\u308c\u3063\u3066\u3069\u3046\u8003\u3048\u305f\u3089\u3044\u3044\u306e\uff1f\u300d\u3068\u60a9\u307e\u308c\u3066\u3044\u308b\u70b9\u306f\u610f\u5916\u3068\u591a\u3044\u306e\u3067\u306f\u306a\u3044\u3067\u3057\u3087\u3046\u304b\u3002NGS\u3092\u4f7f\u7528\u3057\u305f\u89e3\u6790\u306b\u304a\u3044\u3066","og_url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/basic_ngs_gsd_mkt_3\/","og_site_name":"Learning at the Bench","article_publisher":"https:\/\/www.facebook.com\/ThermoFisherJapan","article_published_time":"2021-04-09T07:15:55+00:00","article_modified_time":"2022-04-01T01:06:05+00:00","og_image":[{"width":600,"height":300,"url":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2021\/04\/shutterstock_1536784736-1.jpg","type":"image\/jpeg"}],"author":"LatB Staff","twitter_card":"summary_large_image","twitter_creator":"@ThermoFisherJP","twitter_site":"@ThermoFisherJP","twitter_misc":{"\u57f7\u7b46\u8005":"LatB Staff"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/basic_ngs_gsd_mkt_3\/#article","isPartOf":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/basic_ngs_gsd_mkt_3\/"},"author":{"name":"LatB Staff","@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#\/schema\/person\/bdbe319a2001f279ddce6ab8eaad1253"},"headline":"\u6b21\u4e16\u4ee3\u30b7\u30fc\u30b1\u30f3\u30b5 \u30c7\u30fc\u30bf\u89e3\u6790 \u907a\u4f1d\u5b50\u5909\u7570\u89e3\u6790\u306e\u305f\u3081\u306e\u6700\u9069\u306a\u30ab\u30d0\u30ec\u30c3\u30b8","datePublished":"2021-04-09T07:15:55+00:00","dateModified":"2022-04-01T01:06:05+00:00","mainEntityOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/basic_ngs_gsd_mkt_3\/"},"wordCount":52,"commentCount":0,"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/basic_ngs_gsd_mkt_3\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2021\/04\/shutterstock_1536784736-1.jpg","keywords":["\u6b21\u4e16\u4ee3\u30b7\u30fc\u30b1\u30f3\u30b5"],"articleSection":["\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023"],"inLanguage":"ja","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/basic_ngs_gsd_mkt_3\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/basic_ngs_gsd_mkt_3\/","url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/basic_ngs_gsd_mkt_3\/","name":"\u6b21\u4e16\u4ee3\u30b7\u30fc\u30b1\u30f3\u30b5 \u30c7\u30fc\u30bf\u89e3\u6790 \u907a\u4f1d\u5b50\u5909\u7570\u89e3\u6790\u306e\u305f\u3081\u306e\u6700\u9069\u306a\u30ab\u30d0\u30ec\u30c3\u30b8 - Learning at the Bench","isPartOf":{"@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/basic_ngs_gsd_mkt_3\/#primaryimage"},"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/basic_ngs_gsd_mkt_3\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2021\/04\/shutterstock_1536784736-1.jpg","datePublished":"2021-04-09T07:15:55+00:00","dateModified":"2022-04-01T01:06:05+00:00","author":{"@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#\/schema\/person\/bdbe319a2001f279ddce6ab8eaad1253"},"breadcrumb":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/basic_ngs_gsd_mkt_3\/#breadcrumb"},"inLanguage":"ja","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/basic_ngs_gsd_mkt_3\/"]}]},{"@type":"ImageObject","inLanguage":"ja","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/basic_ngs_gsd_mkt_3\/#primaryimage","url":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2021\/04\/shutterstock_1536784736-1.jpg","contentUrl":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2021\/04\/shutterstock_1536784736-1.jpg","width":600,"height":300},{"@type":"BreadcrumbList","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/basic_ngs_gsd_mkt_3\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/"},{"@type":"ListItem","position":2,"name":"\u6b21\u4e16\u4ee3\u30b7\u30fc\u30b1\u30f3\u30b5 \u30c7\u30fc\u30bf\u89e3\u6790 \u907a\u4f1d\u5b50\u5909\u7570\u89e3\u6790\u306e\u305f\u3081\u306e\u6700\u9069\u306a\u30ab\u30d0\u30ec\u30c3\u30b8"}]},{"@type":"WebSite","@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#website","url":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/","name":"Learning at the Bench","description":"","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"ja"},{"@type":"Person","@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#\/schema\/person\/bdbe319a2001f279ddce6ab8eaad1253","name":"LatB Staff","image":{"@type":"ImageObject","inLanguage":"ja","@id":"https:\/\/secure.gravatar.com\/avatar\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g","caption":"LatB Staff"},"url":"https:\/\/admin.acceleratingscience.com\/author\/lgbadmin\/"}]}},"taxonomy_info":{"category":[{"value":156,"label":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023"}],"post_tag":[{"value":165,"label":"\u6b21\u4e16\u4ee3\u30b7\u30fc\u30b1\u30f3\u30b5"}]},"featured_image_src_large":["https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2021\/04\/shutterstock_1536784736-1.jpg",600,300,false],"author_info":{"display_name":"LatB Staff","author_link":"https:\/\/admin.acceleratingscience.com\/author\/lgbadmin\/"},"comment_info":0,"category_info":[{"term_id":156,"name":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","slug":"mol-bio","term_group":0,"term_taxonomy_id":156,"taxonomy":"category","description":"","parent":0,"count":539,"filter":"raw","meta":[],"cat_ID":156,"category_count":539,"category_description":"","cat_name":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","category_nicename":"mol-bio","category_parent":0}],"tag_info":[{"term_id":165,"name":"\u6b21\u4e16\u4ee3\u30b7\u30fc\u30b1\u30f3\u30b5","slug":"ngs","term_group":0,"term_taxonomy_id":165,"taxonomy":"post_tag","description":"","parent":0,"count":71,"filter":"raw","meta":[]}],"jetpack-related-posts":[{"id":24647,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/sanger-seq-mutational-analysis-gsd-ts-ce-26007\/","url_meta":{"origin":9272,"position":0},"title":"\u30de\u30a4\u30ca\u30fc\u5909\u7570\u3092\u691c\u51fa\uff01Minor Variant Finder\u30bd\u30d5\u30c8\u30a6\u30a8\u30a2","author":"LatB Staff","date":"2026\u5e742\u67089\u65e5","format":false,"excerpt":"\u30ad\u30e3\u30d4\u30e9\u30ea\u30fc\u30b7\u30fc\u30b1\u30f3\u30b5\u3067\u306f\u300125%\u7a0b\u5ea6\u306e\u5272\u5408\u306e\u5909\u7570\u3092\u691c\u51fa\u3059\u308b\u3053\u3068\u304c\u3067\u304d\u307e\u3059\u304c\u3001\u3053\u308c\u3088\u308a\u3082\u4f4e\u3044\u5272\u5408\u306e\u5909\u2026","rel":"","context":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","block_context":{"text":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/mol-bio\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/01\/sanger-seq-mutational-analysis-gsd-ts-ce-26007_eyecatch.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/01\/sanger-seq-mutational-analysis-gsd-ts-ce-26007_eyecatch.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/01\/sanger-seq-mutational-analysis-gsd-ts-ce-26007_eyecatch.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/01\/sanger-seq-mutational-analysis-gsd-ts-ce-26007_eyecatch.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/01\/sanger-seq-mutational-analysis-gsd-ts-ce-26007_eyecatch.jpg?resize=1050%2C600&ssl=1 3x"},"classes":[]},{"id":24953,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/ngs-gene-expression-csd-ts-ion-26011\/","url_meta":{"origin":9272,"position":1},"title":"\u30e9\u30a4\u30d6\u30e9\u30ea\u30fc\u8abf\u88fd\u306e\u81ea\u52d5\u5316\u3067NGS\u306e\u53ef\u80fd\u6027\u3092\u5e83\u3052\u308b\u2015Ion Chef\u30b7\u30b9\u30c6\u30e0\u304c\u5909\u3048\u308b\u7814\u7a76\u5ba4\u306e\u30ef\u30fc\u30af\u30d5\u30ed\u30fc","author":"LatB Staff","date":"2026\u5e744\u670810\u65e5","format":false,"excerpt":"\u524d\u51e6\u7406\u306e\u81ea\u52d5\u5316\u304c\u3001NGS\u306e\u65b0\u3057\u3044\u6a19\u6e96\u3092\u3064\u304f\u308b\u6b21\u4e16\u4ee3\u30b7\u30fc\u30b1\u30f3\u30b7\u30f3\u30b0\uff08NGS\uff09\u304c\u65e5\u5e38\u7684\u306a\u7814\u7a76\u30c4\u30fc\u30eb\u3068\u306a\u3063\u2026","rel":"","context":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","block_context":{"text":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/mol-bio\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/02\/ngs-gene-expression-csd-ts-ion-26011_eyecatch.jpeg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/02\/ngs-gene-expression-csd-ts-ion-26011_eyecatch.jpeg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/02\/ngs-gene-expression-csd-ts-ion-26011_eyecatch.jpeg?resize=525%2C300&ssl=1 1.5x"},"classes":[]},{"id":24187,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/ngs-gene-expression-csd-ts-ion-25073\/","url_meta":{"origin":9272,"position":2},"title":"\u3010\u3084\u3063\u3066\u307f\u305f\u3011\u5fae\u91cf\u30fb\u5206\u89e3RNA\u306b\u3088\u308b\u767a\u73fe\u89e3\u6790\u306e\u6700\u9069\u89e3\u306f\uff1fRNA-Seq\u3068Ion AmpliSeq Transcriptome\u3092\u6bd4\u3079\u3066\u307f\u305f","author":"LatB Staff","date":"2025\u5e7411\u670828\u65e5","format":false,"excerpt":"\u6b21\u4e16\u4ee3\u30b7\u30fc\u30b1\u30f3\u30b5\u3067\u306e\u767a\u73fe\u89e3\u6790\u306b\u53d6\u308a\u7d44\u3080\u969b\u3001RNA\u30b5\u30f3\u30d7\u30eb\u304c\u300c\u5c11\u306a\u3059\u304e\u308b\u300d\u300c\u5206\u89e3\u3057\u3066\u3044\u308b\u300d\u3068\u3044\u3046\u72b6\u6cc1\u306f\u2026","rel":"","context":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","block_context":{"text":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/mol-bio\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/11\/ngs-gene-expression-csd-ts-ion-25073_eyecatch-scaled.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/11\/ngs-gene-expression-csd-ts-ion-25073_eyecatch-scaled.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/11\/ngs-gene-expression-csd-ts-ion-25073_eyecatch-scaled.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/11\/ngs-gene-expression-csd-ts-ion-25073_eyecatch-scaled.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/11\/ngs-gene-expression-csd-ts-ion-25073_eyecatch-scaled.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/11\/ngs-gene-expression-csd-ts-ion-25073_eyecatch-scaled.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":20152,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/exosome-nucleic-acid-purification-ts-r-25017\/","url_meta":{"origin":9272,"position":3},"title":"\u3010\u7b2c3\u56de\u3011\u201cRNA cargo\u201d\u306e\u7cbe\u88fd\u3068\u5b9a\u91cf\u89e3\u6790","author":"LatB Staff","date":"2026\u5e745\u670813\u65e5","format":false,"excerpt":"\u7b2c2\u56de\u3067\u306f\u3001\u57f9\u990a\u4e0a\u6e05\u3084\u3055\u307e\u3056\u307e\u306a\u4f53\u6db2\u30b5\u30f3\u30d7\u30eb\u304b\u3089\u306e\u30a8\u30af\u30bd\u30bd\u30fc\u30e0\u306e\u6fc3\u7e2e\u30fb\u56de\u53ce\u65b9\u6cd5\u306b\u3064\u3044\u3066\u7d39\u4ecb\u3057\u307e\u3057\u305f\u304c\u2026","rel":"","context":"\u305d\u306e\u4ed6","block_context":{"text":"\u305d\u306e\u4ed6","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/else\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/f17931341a23d82235760ed66ded9c41.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/f17931341a23d82235760ed66ded9c41.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/f17931341a23d82235760ed66ded9c41.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/f17931341a23d82235760ed66ded9c41.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/f17931341a23d82235760ed66ded9c41.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/f17931341a23d82235760ed66ded9c41.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":24462,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/battery-development-microscopy-csm-25076\/","url_meta":{"origin":9272,"position":4},"title":"\u5168\u56fa\u4f53\u96fb\u6c60\u306e\u9769\u65b0\u3092\u652f\u3048\u308b\u5148\u7aef\u7684\u7279\u6027\u8a55\u4fa1\u6280\u8853\u306e\u63a2\u7a76","author":"LatB Staff","date":"2025\u5e7412\u670817\u65e5","format":false,"excerpt":"\u5168\u56fa\u4f53\u96fb\u6c60\u306e\u958b\u767a\u3067\u306f\u3001\u4f7f\u7528\u3055\u308c\u308b\u6750\u6599\u306e\u7406\u89e3\u3092\u6df1\u3081\u308b\u305f\u3081\u306b\u3001\u5148\u7aef\u7684\u306a\u6027\u8a55\u4fa1\u6280\u8853\u304c\u4e0d\u53ef\u6b20\u3067\u3059\u3002\u3053\u308c\u3089\u306e\u624b\u2026","rel":"","context":"\u5206\u6790\u30fb\u6e2c\u5b9a\u95a2\u9023","block_context":{"text":"\u5206\u6790\u30fb\u6e2c\u5b9a\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/analysis\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/12\/battery-development-microscopy-csm-25076_eyecatch.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/12\/battery-development-microscopy-csm-25076_eyecatch.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/12\/battery-development-microscopy-csm-25076_eyecatch.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/12\/battery-development-microscopy-csm-25076_eyecatch.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/12\/battery-development-microscopy-csm-25076_eyecatch.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/12\/battery-development-microscopy-csm-25076_eyecatch.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":25325,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/exosome-gene-expression-ts-r-25019\/","url_meta":{"origin":9272,"position":5},"title":"\u3010\u7b2c5\u56de\u3011 &#8220;RNA cargo&#8221;\u306e\u7cbe\u88fd\u3068\u5b9a\u91cf\u89e3\u6790\u300d\uff5emRNA\u306e\u5b9a\u91cf\u89e3\u6790\uff5e","author":"LatB Staff","date":"2026\u5e746\u670811\u65e5","format":false,"excerpt":"\u4eca\u56de\u306f\u3001\u30a8\u30af\u30bd\u30bd\u30fc\u30e0\uff08\u30a8\u30ad\u30bd\u30bd\u30fc\u30e0\uff09\u4e2d\u306emRNA\u306e\u5b9a\u91cf\u89e3\u6790\u306b\u3064\u3044\u3066\u8aac\u660e\u3057\u307e\u3059\u3002\u7b2c3\u56de\u3067\u30a8\u30af\u30bd\u30bd\u30fc\u30e0\u304b\u2026","rel":"","context":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","block_context":{"text":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/mol-bio\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25018_eyecatch-1.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25018_eyecatch-1.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25018_eyecatch-1.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25018_eyecatch-1.jpg?resize=700%2C400&ssl=1 2x"},"classes":[]}],"jetpack_sharing_enabled":true,"amp_enabled":true,"jetpack_featured_media_url":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2021\/04\/shutterstock_1536784736-1.jpg","_links":{"self":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/posts\/9272","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/users\/975"}],"replies":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/comments?post=9272"}],"version-history":[{"count":0,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/posts\/9272\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/media\/9297"}],"wp:attachment":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/media?parent=9272"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/categories?post=9272"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/tags?post=9272"},{"taxonomy":"division","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/division?post=9272"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}