{"id":952,"date":"2019-01-10T00:00:00","date_gmt":"2019-01-10T00:00:00","guid":{"rendered":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/cancer7\/"},"modified":"2025-02-28T14:48:18","modified_gmt":"2025-02-28T05:48:18","slug":"cancer7","status":"publish","type":"post","link":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/cancer7\/","title":{"rendered":"\u3010\u3044\u307e\u3055\u3089\u805e\u3051\u306a\u3044\u304c\u3093\u306e\u57fa\u790e 7\u3011\u304c\u3093\u5897\u6b96\u30b7\u30b0\u30ca\u30eb\u3068\u30bf\u30fc\u30b2\u30c6\u30a3\u30f3\u30b0"},"content":{"rendered":"\n<h2>\u304c\u3093\u7d30\u80de\u306e\u5897\u6b96<\/h2>\n<p>\u907a\u4f1d\u5b50\u5909\u7570\u306e\u84c4\u7a4d\u306f\u3001\u6700\u7d42\u7684\u306b\u7d30\u80de\u5468\u671f\u8abf\u7bc0\u306b\u5fc5\u8981\u3068\u3055\u308c\u308b\u30e1\u30ab\u30cb\u30ba\u30e0\u3092\u59a8\u3052\u307e\u3059\u3002\u6b63\u5e38\u306a\u72b6\u614b\u3067\u306f\u3001\u5897\u6b96\u30b7\u30b0\u30ca\u30eb\u306e\u7523\u751f\u304a\u3088\u3073\u4f1d\u64ad\u306a\u3089\u3073\u306b\u7d30\u80de\u5897\u6b96\u304c\u9ad8\u5ea6\u306b\u8abf\u7bc0\u3055\u308c\u3066\u3044\u307e\u3059\u3002\u5897\u6b96\u30d7\u30ed\u30bb\u30b9\u306e\u53b3\u5bc6\u306a\u5236\u5fa1\u306f\u3001\u5065\u5168\u306a\u7d44\u7e54\u306e\u69cb\u9020\u304a\u3088\u3073\u6a5f\u80fd\u306e\u7dad\u6301\u3092\u30b5\u30dd\u30fc\u30c8\u3057\u307e\u3059\u3002\u5897\u6b96\u306b\u95a2\u9023\u3059\u308b\u30b7\u30b0\u30ca\u30eb\u4f1d\u9054\u7d4c\u8def\u306f\u3001\u901a\u5e38\u3001\u5fc5\u8981\u306b\u306a\u308b\u3068\u6d3b\u6027\u5316\u3055\u308c\u3001\u4e0d\u8981\u306b\u306a\u308b\u3068\u4e0d\u6d3b\u6027\u5316\u3055\u308c\u307e\u3059\u3002<\/p>\n<h4>\u7d30\u80de\u5468\u671f\u8abf\u7bc0\u4e0d\u5168<\/h4>\n<p>\u60aa\u6027\u7d30\u80de\u306e\u30db\u30fc\u30eb\u30de\u30fc\u30af\uff08\u7279\u5fb4\uff09\u306e\u4e00\u3064\u306f\u3001\u6052\u5e38\u7684\u8abf\u7bc0\u306e\u55aa\u5931\u304a\u3088\u3073\u6301\u7d9a\u7684\u3001\u3042\u308b\u3044\u306f\u5236\u5fa1\u4e0d\u80fd\u306a\u5897\u6b96\u3067\u3059\u3002\u6b63\u5e38\u306a\u30db\u30e1\u30aa\u30b9\u30bf\u30b7\u30b9\u3092\u7dad\u6301\u3059\u308b\u305f\u3081\u306b\u3001\u7d30\u80de\u5206\u88c2\u5468\u671f\u306f\u53b3\u5bc6\u306b\u5236\u5fa1\u3055\u308c\u3066\u3044\u307e\u3059\uff08\u56f32.1\uff09\u3002\u30d2\u30c8\u304c\u3093\u3067\u306f\u3001\u7d30\u80de\u5468\u671f\u306eG1\u671f\u306b\u8abf\u7bc0\u4e0d\u5168\u304c\u751f\u3058\u3001\u305d\u3053\u3067\u7d30\u80de\u306f\u5897\u6b96\u3092\u958b\u59cb\u3059\u308b\u304b\u3001\u7d30\u80de\u5468\u671f\u304b\u3089\u9038\u8131\u3057G0\u671f\u306e\u9759\u6b62\u72b6\u614b\u306b\u5165\u308b\u3053\u3068\u304c\u7814\u7a76\u8005\u306b\u3088\u3063\u3066\u78ba\u8a8d\u3055\u308c\u307e\u3057\u305f\u00a0<sup>*1\u20133<\/sup>\u3002<\/p>\n<p><a href=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/1-58.jpg\"><img loading=\"lazy\" decoding=\"async\" class=\"size-full wp-image-3036 aligncenter\" src=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/1-58.jpg\" alt=\"\u304c\u3093\u30c9\u30e9\u30a4\u30d0\u30fc\u304a\u3088\u3073\u305d\u306e\u7d30\u80de\u5468\u671f\" width=\"494\" height=\"469\" \/><\/a> <a href=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/2-10.jpg\"><img loading=\"lazy\" decoding=\"async\" class=\"size-full wp-image-3037 aligncenter\" src=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/2-10.jpg\" alt=\"Phospho-CENP-A pSer7 Rabbit Polyclonal Antibody\" width=\"481\" height=\"315\" \/><\/a><\/p>\n<h4>\u7d30\u80de\u5897\u6b96\u306e\u691c\u51fa<\/h4>\n<p>\u816b\u760d\u6291\u5236\u56e0\u5b50TP53\u3092\u30b3\u30fc\u30c9\u3059\u308b\u907a\u4f1d\u5b50\u306b\u304a\u3051\u308b\u4f53\u7d30\u80de\u5909\u7570\u306f\u3001\u30d2\u30c8\u30b2\u30ce\u30e0\u306e\u4ed6\u306e\u65e2\u77e5\u306e\u30c9\u30e9\u30a4\u30d0\u30fc\u907a\u4f1d\u5b50\u306b\u5f71\u97ff\u3092\u53ca\u307c\u3059\u5909\u7570\u3088\u308a\u3082\u9ad8\u983b\u5ea6\u3067\u767a\u751f\u3057\u307e\u3059\u3002p53\u30b7\u30b0\u30ca\u30eb\u4f1d\u9054\u306e\u8abf\u7bc0\u4e0d\u5168\u306f\u3001\u7121\u5236\u5fa1\u306a\u7d30\u80de\u5897\u6b96\u3092\u5f15\u304d\u8d77\u3053\u3057\u307e\u3059\u3002\u307e\u305f\u3001TP53\u306b\u304a\u3051\u308b\u751f\u6b96\u7d30\u80de\u7cfb\u5217\u306e\u7570\u5e38\u306f\u3001\u30ea\u30fb\u30d5\u30e9\u30a6\u30e1\u30cb\u75c7\u5019\u7fa4\u2015\u3055\u307e\u3056\u307e\u306a\u304c\u3093\u306e\u65e9\u671f\u767a\u75c7\u306e\u7d20\u56e0\u304c\u3042\u308b\u72b6\u614b\u2015\u3092\u751f\u3058\u307e\u3059\u3002p53\u306b\u95a2\u3059\u308b\u60c5\u5831\u306f\u30011979\u5e74\u306b\u521d\u3081\u3066\u767a\u8868\u3055\u308c\u3001\u305d\u306e\u6570\u5341\u5e74\u5f8c\u306b\u907a\u4f1d\u5b50\u306e\u767a\u304c\u3093\u7279\u6027\u306b\u3064\u3044\u3066\u78ba\u8a8d\u3055\u308c\u307e\u3057\u305f\u00a0<sup>*4,5<\/sup>\u3002<\/p>\n<p><a href=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/1-59.jpg\"><img loading=\"lazy\" decoding=\"async\" class=\"size-full wp-image-3038 aligncenter\" src=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/1-59.jpg\" alt=\"p53 Mouse Monoclonal Antibody (DO-7)\" width=\"482\" height=\"255\" \/><\/a> <a href=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/2-11.jpg\"><img loading=\"lazy\" decoding=\"async\" class=\"size-full wp-image-3039 aligncenter\" src=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/2-11.jpg\" alt=\"HCS Mitotic Index Kit\" width=\"978\" height=\"477\" \/><\/a><\/p>\n<p>\u5f53\u8a18\u4e8b\u306f\u3001\u304c\u3093\u5897\u6b96\u30b7\u30b0\u30ca\u30eb\u4f1d\u9054\u7d4c\u8def\u306e\u63a2\u7d22\u30ac\u30a4\u30c9\u30d6\u30c3\u30af\u304b\u3089\u306e\u629c\u7c8b\u3067\u3059\u3002<br \/>\n\u30ac\u30a4\u30c9\u30d6\u30c3\u30af\u306f\u4e0b\u8a18\u304b\u3089\u7121\u6599\u3067\u30c0\u30a6\u30f3\u30ed\u30fc\u30c9\u9802\u3051\u307e\u3059\u3002<\/p>\n<p><strong><a class=\"btn btn-red\" href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/global\/forms\/antibody-cancer-guidebook-form.html?CID=bid_pca_aup_r04_jp_cp0000_pjt0000_bid00000_0so_blg_op_awa_oc_s00_ab12_Social_LAB\" target=\"_blank\" rel=\"noopener\">\u7121\u6599\u30ac\u30a4\u30c9\u30d6\u30c3\u30af\u3092\u30c0\u30a6\u30f3\u30ed\u30fc\u30c9\u3059\u308b<\/a><\/strong><\/p>\n<h2>\u5897\u6b96\u56e0\u5b50\u7d4c\u8def\u306e\u8abf\u7bc0\u4e0d\u5168<\/h2>\n<h4>\u5897\u6b96\u56e0\u5b50\u30b7\u30b0\u30ca\u30eb\u4f1d\u9054<\/h4>\n<p>\u6b63\u5e38\u7d30\u80de\u304a\u3088\u3073\u591a\u304f\u306e\u816b\u760d\u306b\u304a\u3044\u3066\u3001G1\u521d\u671f\u306f\u3001\u30de\u30a4\u30c8\u30b8\u30a7\u30f3\u4f9d\u5b58\u6027\u3067\u3001\u5897\u6b96\u56e0\u5b50\u306e\u5b58\u5728\u3092\u5fc5\u8981\u3068\u3057\u307e\u3059\u3002\u4e00\u65b9\u3001G1\u5f8c\u671f\u306f\u30de\u30a4\u30c8\u30b8\u30a7\u30f3\u523a\u6fc0\u306b\u4f9d\u5b58\u305b\u305a\u306b\u7d99\u7d9a\u3057\u307e\u3059\u3002\u3057\u304b\u3057\u306a\u304c\u3089\u3001\u4e00\u90e8\u306e\u816b\u760d\u306f\u30ea\u30ac\u30f3\u30c9\u4f9d\u5b58\u6027\u306e\u5897\u6b96\u56e0\u5b50\u30b7\u30b0\u30ca\u30eb\u306e\u975e\u5b58\u5728\u4e0b\u306b\u304a\u3051\u308b\u5897\u6b96\u80fd\u3092\u7372\u5f97\u3057\u307e\u3059\u3002\u816b\u760d\u7d30\u80de\u5897\u6b96\u306b\u95a2\u4e0e\u3059\u308b\u3068\u8003\u3048\u3089\u308c\u308b\u5897\u6b96\u56e0\u5b50\u7d4c\u8def\u306e\u591a\u69d8\u6027\u3092\u56f32.2\u306b\u793a\u3057\u307e\u3059\u00a0<sup>*6,7<\/sup>\u3002<br \/>\n\u4e0a\u76ae\u6210\u9577\u56e0\u5b50\u53d7\u5bb9\u4f53\uff08EGFR\uff09\u3092\u4ecb\u3059\u308b\u816b\u760d\u7d30\u80de\u30b7\u30b0\u30ca\u30eb\u4f1d\u9054\u306f\u3001\u30ea\u30ac\u30f3\u30c9\u4f9d\u5b58\u6027\u304a\u3088\u3073\u30ea\u30ac\u30f3\u30c9\u975e\u4f9d\u5b58\u6027\u306e\u53d7\u5bb9\u4f53\u6d3b\u6027\u5316\u6a5f\u69cb\u3092\u4ecb\u3057\u3066\u6a5f\u80fd\u3057\u307e\u3059\u3002\u4f8b\u3048\u3070\u3001\u7279\u5b9a\u306e\u30bf\u30a4\u30d7\u306e\u795e\u7d4c\u81a0\u82bd\u816b\u306f\u3001EGFR\u306e\u7d30\u80de\u5916\u30c9\u30e1\u30a4\u30f3\u306e\u6b20\u5931\u3092\u62b1\u3048\u3066\u3044\u308b\u306b\u3082\u304b\u304b\u308f\u3089\u305a\u3001\u69cb\u6210\u7684\u6d3b\u6027\u5316\u578b\u306e\u30b7\u30b0\u30ca\u30eb\u4f1d\u9054\u3092\u4ecb\u3057\u3066\u767a\u73fe\u3057\u307e\u3059\u00a0<sup>*8<\/sup>\u3002<br \/>\n\u304c\u3093\u5897\u6b96\u304a\u3088\u3073\u6210\u9577\u306e\u8abf\u7bc0\u4e0d\u5168\u306b\u3064\u3044\u3066\u306f\u3001\u591a\u304f\u306e\u70b9\u306b\u304a\u3044\u3066\u660e\u3089\u304b\u306b\u3055\u308c\u3066\u3044\u307e\u3059\u00a0<sup>*2<\/sup>\u3002<\/p>\n<ul>\n<li>\u816b\u760d\u306b\u3088\u308b\u5897\u6b96\u56e0\u5b50\u7523\u751f\u5897\u52a0\u306e\u53ef\u80fd\u6027<\/li>\n<li>\u60aa\u6027\u7d30\u80de\u8868\u9762\u306b\u304a\u3051\u308b\u5897\u6b96\u56e0\u5b50\u53d7\u5bb9\u4f53\u6570\u5897\u52a0\u306e\u53ef\u80fd\u6027<\/li>\n<li>\u5f62\u8cea\u8ee2\u63db\u7d30\u80de\u306b\u304a\u3051\u308b\u53d7\u5bb9\u4f53\u69cb\u9020\u5909\u5316\u306e\u53ef\u80fd\u6027<\/li>\n<li>\u816b\u760d\u5fae\u5c0f\u74b0\u5883\u306b\u304a\u3044\u3066\u7523\u751f\u3057\u305f\u5897\u6b96\u56e0\u5b50\u306b\u5bfe\u3057\u3001\u304c\u3093\u6027\u7d30\u80de\u304c\u4e0d\u9069\u5207\u306b\u53cd\u5fdc\u3059\u308b\u53ef\u80fd\u6027<\/li>\n<li>\u5897\u6b96\u56e0\u5b50\u53d7\u5bb9\u4f53\u306e\u30bf\u30f3\u30d1\u30af\u8cea\u4e0b\u6d41\u306e\u8abf\u7bc0\u4e0d\u5168\u306e\u53ef\u80fd\u6027<\/li>\n<\/ul>\n<p><a href=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/1-60.jpg\"><img loading=\"lazy\" decoding=\"async\" class=\"size-full wp-image-3040 aligncenter\" src=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/1-60.jpg\" alt=\"\u816b\u760d\u5f62\u6210\u306b\u95a2\u4e0e\u3059\u308b\u4e00\u822c\u7684\u306a\u53d7\u5bb9\u4f53\u578b\u30c1\u30ed\u30b7\u30f3\u30ad\u30ca\u30fc\u30bc\u7d4c\u8def\" width=\"485\" height=\"685\" \/><\/a><\/p>\n<h2>\u5897\u6b96\u56e0\u5b50\u53d7\u5bb9\u4f53\u7d4c\u8def\u3078\u306e\u30bf\u30fc\u30b2\u30c6\u30a3\u30f3\u30b0<\/h2>\n<h4>\u53d7\u5bb9\u4f53\u578b\u30c1\u30ed\u30b7\u30f3\u30ad\u30ca\u30fc\u30bc\uff08RTK\uff09<\/h4>\n<p>\u901a\u5e38\u3001\u5897\u6b96\u56e0\u5b50\u53d7\u5bb9\u4f53\u578b\u30c1\u30ed\u30b7\u30f3\u30ad\u30ca\u30fc\u30bc\u306e\u6d3b\u6027\u5316\u306f\u3001\u30ea\u30ac\u30f3\u30c9\u306e\u53d7\u5bb9\u4f53\u7d30\u80de\u5916\u30c9\u30e1\u30a4\u30f3\u3078\u306e\u7d50\u5408\u304b\u3089\u59cb\u307e\u308a\u307e\u3059\uff08\u56f32.3\uff09\u3002\u7d9a\u3044\u3066\u3001\u53d7\u5bb9\u4f53\u306e\u7d30\u80de\u8cea\u5074\u672b\u7aef\u306e\u30ad\u30ca\u30fc\u30bc\u30c9\u30e1\u30a4\u30f3\u306e\u30c1\u30ed\u30b7\u30f3\u6b8b\u57fa\u306e\u81ea\u5df1\u30ea\u30f3\u9178\u5316\u304c\u751f\u3058\u3001\u7d30\u80de\u5897\u6b96\u304a\u3088\u3073\u4ed6\u306e\u30d7\u30ed\u30bb\u30b9\u306b\u91cd\u8981\u306a\u907a\u4f1d\u5b50\u3092\u5236\u5fa1\u3059\u308b\u4e0b\u6d41\u30b7\u30b0\u30ca\u30eb\u4f1d\u9054\u30bf\u30f3\u30d1\u30af\u8cea\u306e\u305f\u3081\u306e\u30c9\u30c3\u30ad\u30f3\u30b0\u30b9\u30c6\u30fc\u30b7\u30e7\u30f3\u3068\u3057\u3066\u6a5f\u80fd\u3057\u307e\u3059\u3002<\/p>\n<p>\u4e0a\u76ae\u6210\u9577\u56e0\u5b50\uff08EGF\uff09\u306f\u3001\u4e0a\u76ae\u816b\u760d\u306b\u304a\u3044\u3066\u9ad8\u767a\u73fe\u3059\u308b\u30bf\u30f3\u30d1\u30af\u8cea\u3067\u3042\u308bEGFR\u306b\u7d50\u5408\u3057\u307e\u3059\u3002EGFR\u7d4c\u8def\u306f\u6a19\u7684\u6cbb\u7642\u306e\u30e2\u30c7\u30eb\u3067\u3001\u5b9f\u969b\u306b\u304c\u3093\u6cbb\u7642\u85ac\u306e\u6a19\u7684\u3068\u3057\u3066\u306e\u6700\u521d\u306e\u5897\u6b96\u56e0\u5b50\u53d7\u5bb9\u4f53\u3068\u3057\u3066\u63d0\u5531\u3055\u308c\u307e\u3057\u305f\u3002\u816b\u760d\u7d30\u80de\u5897\u6b96\u306b\u95a2\u4e0e\u3059\u308b\u4e00\u822c\u7684\u306a\u5897\u6b96\u56e0\u5b50\u7d4c\u8def\u306e\u4ee3\u8868\u4f8b\u3092\u88682.1.\u306b\u793a\u3057\u307e\u3059\u3002\u304c\u3093\u6cbb\u7642\u85ac\u3068\u3057\u3066\u627f\u8a8d\u3055\u308c\u305f\u30c1\u30ed\u30b7\u30f3\u30ad\u30ca\u30fc\u30bc\u963b\u5bb3\u5264\uff08TKI\uff09\u306e\u6a19\u7684\u3068\u3055\u308c\u3066\u3044\u308b\u5897\u6b96\u56e0\u5b50\u53d7\u5bb9\u4f53\u306f\u592a\u5b57\u3067\u8868\u793a\u3057\u3066\u3044\u307e\u3059\u00a0<sup>*7<\/sup>\u3002<\/p>\n<p><a href=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/1-61.jpg\"><img loading=\"lazy\" decoding=\"async\" class=\"size-full wp-image-3041 aligncenter\" src=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/1-61.jpg\" alt=\"\u4e0a\u76ae\u6210\u9577\u56e0\u5b50\u53d7\u5bb9\u4f53\" width=\"487\" height=\"408\" \/><\/a> <a href=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/2-12.jpg\"><img loading=\"lazy\" decoding=\"async\" class=\"size-full wp-image-3042 aligncenter\" src=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/2-12.jpg\" alt=\"\u816b\u760d\u5f62\u6210\u306b\u95a2\u4e0e\u3059\u308b\u4ee3\u8868\u7684\u306a\u5897\u6b96\u56e0\u5b50\u304a\u3088\u3073\u53d7\u5bb9\u4f53\u578b\u30c1\u30ed\u30b7\u30f3\u30ad\u30ca\u30fc\u30bc\" width=\"1020\" height=\"763\" \/><\/a><\/p>\n<h4>\u304c\u3093\u7814\u7a76\u306e\u305f\u3081\u306e\u30a4\u30e0\u30ce\u30a2\u30c3\u30bb\u30a4<\/h4>\n<p><strong>EGFR In-Cell ELISA\u30ad\u30c3\u30c8<\/strong><br \/>\n\u9175\u7d20\u7d50\u5408\u514d\u75ab\u5438\u7740\u6e2c\u5b9a\u6cd5\uff08ELISA\uff09\u306f\u3001\u30bf\u30f3\u30d1\u30af\u8cea\u5b9a\u91cf\u306e\u6a19\u6e96\u7684\u306a\u624b\u6cd5\u3067\u3059\u3002ELISA\u306f\u3001\u6bd4\u8f03\u7684\u89e3\u6790\u304c\u5bb9\u6613\u3067\u3001\u8fc5\u901f\u306b\u7d50\u679c\u304c\u5f97\u3089\u308c\u308b\u305f\u3081\u3001\u30cf\u30a4\u30b9\u30eb\u30fc\u30d7\u30c3\u30c8\u30b9\u30af\u30ea\u30fc\u30cb\u30f3\u30b0\u306b\u5bfe\u5fdc\u53ef\u80fd\u3067\u3059\u3002\u5f53\u793e\u306f\u3001\u816b\u760d\u5b66\u3001\u514d\u75ab\u5b66\u3001\u795e\u7d4c\u751f\u7269\u5b66\u3001\u5e79\u7d30\u80de\u7814\u7a76\u3001\u304a\u3088\u3073\u4ed6\u306e\u5206\u91ce\u306b\u304a\u3051\u308b\u30bf\u30f3\u30d1\u30af\u8cea\u306e\u5b9a\u91cf\u304a\u3088\u3073\u89e3\u6790\u3092\u652f\u63f4\u3059\u308b\u305f\u3081\u306e\u5e45\u5e83\u3044\u88fd\u54c1\u3092\u63d0\u4f9b\u3057\u3066\u3044\u307e\u3059\u3002<br \/>\n<a href=\"http:\/\/www.thermofisher.com\/in-cell-ELISA?CID=bid_pca_aup_r04_jp_cp0000_pjt0000_bid00000_0so_blg_op_awa_oc_s00_ab12_Social_LAB\" target=\"_blank\" rel=\"noopener\">Thermo Scientific\u2122 Pierce\u2122 EGFR Colorimetric In-Cell ELISA Kit\uff08\u88fd\u54c1\u756a\u53f7 62205\uff09\u306b\u95a2\u3059\u308b\u8a73\u3057\u3044\u60c5\u5831\u306f\u3053\u3061\u3089\u3092\u3054\u89a7\u304f\u3060\u3055\u3044\u3002<\/a><br \/>\n\u307e\u305f\u3001\u304c\u3093\u7814\u7a76\u304a\u3088\u3073\u4ed6\u306e\u7814\u7a76\u5206\u91ce\u306b\u95a2\u9023\u3059\u308b\u5e83\u7bc4\u306a\u30bf\u30fc\u30b2\u30c3\u30c8\u3092\u7814\u7a76\u3059\u308b\u305f\u3081\u306e\u6570\u767e\u3082\u306eELISA\u30ad\u30c3\u30c8\u304a\u3088\u3073\u4ed6\u306e\u30a4\u30e0\u30ce\u30a2\u30c3\u30bb\u30a4\u3082\u63d0\u4f9b\u3057\u3066\u3044\u307e\u3059\u3002<a href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/life-science\/antibodies\/immunoassays.html?CID=bid_pca_aup_r04_jp_cp0000_pjt0000_bid00000_0so_blg_op_awa_oc_s00_ab12_Social_LAB\" target=\"_blank\" rel=\"noopener\">\u5f53\u793e\u306e\u30a4\u30e0\u30ce\u30a2\u30c3\u30bb\u30a4\u306b\u95a2\u3059\u308b\u8a73\u3057\u3044\u60c5\u5831\u306f\u3053\u3061\u3089\u3092\u3054\u89a7\u304f\u3060\u3055\u3044\u3002<\/a><\/p>\n<p><a href=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/1-62.jpg\"><img loading=\"lazy\" decoding=\"async\" class=\"size-full wp-image-3043 aligncenter\" src=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/1-62.jpg\" alt=\"Thermo Scientific Pierce EGFR in-cell ELISA\u30ad\u30c3\u30c8\u306e\u8fd1\u8d64\u5916\u5149\u691c\u51fa\u6cd5\u3068 \u6bd4\u8272\u691c\u51fa\u6cd5\u306b\u3088\u308b\u7d50\u679c\u306f\u8fd1\u4f3c\" width=\"490\" height=\"343\" \/><\/a> <a href=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/2-13.jpg\"><img loading=\"lazy\" decoding=\"async\" class=\"size-full wp-image-3044 aligncenter\" src=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/2-13.jpg\" alt=\"EGFR in-cell ELISA\u30ad\u30c3\u30c8\u306f\u3001EGFR\u30bf\u30f3\u30d1\u30af\u8cea\u306e\u30ec\u30d9 \u30eb\u3001\u6d3b\u6027\u5316\u3001\u304a\u3088\u3073\u6291\u5236\u3092\u6e2c\u5b9a\u3059\u308b\u305f\u3081\u306e\u8fc5\u901f\u304b\u3064\u78ba\u5b9f\u306a \u30d5\u30a9\u30fc\u30de\u30c3\u30c8\u3092\u63d0\u4f9b\" width=\"988\" height=\"466\" \/><\/a><\/p>\n<h4>\u304c\u3093\u306b\u304a\u3051\u308b\u8840\u7ba1\u5185\u76ae\u5897\u6b96\u56e0\u5b50\u30b7\u30b0\u30ca\u30eb\u4f1d\u9054<\/h4>\n<p>EGFR\u306a\u3069\u306e\u53d7\u5bb9\u4f53\u578b\u30c1\u30ed\u30b7\u30f3\u30ad\u30ca\u30fc\u30bc\uff08RTK\uff09\u306f\u3001\u9577\u3044\u9593\u3001\u816b\u760d\u7d30\u80de\u5897\u6b96\u3068\u306e\u95a2\u9023\u6027\u304c\u793a\u5506\u3055\u308c\u3066\u304d\u307e\u3057\u305f\u3002\u8840\u7ba1\u5185\u76ae\u5897\u6b96\u56e0\u5b50\uff08VEGF\uff09\u304a\u3088\u3073\u305d\u306eRTK\u3001VEGF\u53d7\u5bb9\u4f53\uff08VEGFR\uff09\u306f\u3001\u816b\u760d\u5897\u6b96\u306b\u9ad8\u983b\u5ea6\u3067\u5bc4\u4e0e\u3059\u308b\u4ed6\u306e\u30b7\u30b0\u30ca\u30eb\u4f1d\u9054\u30cd\u30c3\u30c8\u30ef\u30fc\u30af\u3067\u3059\uff08\u56f32.4\uff09\u3002\u3057\u304b\u3057\u306a\u304c\u3089\u3001VEGF\u304a\u3088\u3073VEGFR\u306f\u3001\u304c\u3093\u3084\u7cd6\u5c3f\u75c5\u306a\u3069\u306e\u75be\u60a3\u306b\u5bc4\u4e0e\u3059\u308b\u75c5\u7684\u8840\u7ba1\u65b0\u751f\u306b\u95a2\u9023\u3059\u308b\u7570\u5e38\u5236\u5fa1\u3068\u6700\u3082\u5bc6\u63a5\u306b\u95a2\u4fc2\u3057\u3066\u3044\u307e\u3059\u3002<br \/>\nVEGF-A\u306eVEGF\u53d7\u5bb9\u4f532\uff08VEGFR-2\uff09\u3078\u306e\u7d50\u5408\u306f\u3001Ras\/Raf\/MAPK\/ERK\u7d4c\u8def\u304a\u3088\u3073PI3K\/Akt\/mTOR\u7d4c\u8def\u306e\u6d3b\u6027\u5316\u3092\u4ecb\u3059\u308b\u5185\u76ae\u7d30\u80de\u306e\u5897\u6b96\u306b\u3064\u306a\u304c\u308a\u307e\u3059\u00a0<sup>*20<\/sup> \u3002\u8fd1\u5e74\u3001\u8840\u7ba1\u65b0\u751f\u304a\u3088\u3073VEGF\u7d4c\u8def\u3092\u963b\u5bb3\u3059\u308b\u8907\u6570\u306e\u85ac\u5264\u304c\u3001\u80ba\u3001\u81b5\u81d3\u3001\u814e\u81d3\u3001\u80c3\u3001\u809d\u81d3\u3001\u304a\u3088\u3073\u4ed6\u306e\u5668\u5b98\u306e\u7279\u5b9a\u306e\u304c\u3093\u306b\u5bfe\u3059\u308b\u6cbb\u7642\u85ac\u3068\u3057\u3066FDA\u304a\u3088\u3073\u4ed6\u306e\u4e16\u754c\u306e\u533b\u85ac\u54c1\u898f\u5236\u5f53\u5c40\u306b\u627f\u8a8d\u3055\u308c\u3066\u3044\u307e\u3059\u3002\u5b8c\u5168\u306b\u306f\u7db2\u7f85\u3057\u3066\u3044\u307e\u305b\u3093\u304c\u3001VEGF\u7d4c\u8def\u3092\u6a19\u7684\u3068\u3059\u308b\u963b\u5bb3\u5264\u306e\u30ea\u30b9\u30c8\u3092\u88682.3\u306b\u793a\u3057\u307e\u3059\u3002\u3053\u308c\u3089\u306e\u85ac\u5264\u306e\u5927\u90e8\u5206\u306f\u30de\u30eb\u30c1\u30ad\u30ca\u30fc\u30bc\u963b\u5bb3\u5264\u3067\u3042\u308b\u3053\u3068\u306b\u6ce8\u76ee\u3057\u3066\u304f\u3060\u3055\u3044\u00a0<sup>*21\u00a0<\/sup>\u3002<br \/>\n\u7814\u7a76\u8005\u305f\u3061\u306f\u3001VEGF\u7d4c\u8def\u304c\u816b\u760d\u8840\u7ba1\u65b0\u751f\u3092\u30b5\u30dd\u30fc\u30c8\u3059\u308b\u30d7\u30ed\u30bb\u30b9\u306b\u6975\u3081\u3066\u91cd\u8981\u3067\u3042\u308b\u3053\u3068\u306b\u52a0\u3048\u3066\u3001VEGF\u7d4c\u8def\u30b7\u30b0\u30ca\u30eb\u4f1d\u9054\u306f\u4e73\u304c\u3093\u7d30\u80de\u682a\u306e\u5897\u6b96\u306b\u76f4\u63a5\u5f71\u97ff\u3092\u53ca\u307c\u3059\u53ef\u80fd\u6027\u306b\u3064\u3044\u3066\u3082\u5831\u544a\u3057\u3066\u3044\u307e\u3059\u00a0<sup>*22<\/sup>\u3002<\/p>\n<p><a href=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/1-63.jpg\"><img loading=\"lazy\" decoding=\"async\" class=\"size-full wp-image-3045 aligncenter\" src=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/1-63.jpg\" alt=\"\u8840\u7ba1\u5185\u76ae\u5897\u6b96\u56e0\u5b50\u304a\u3088\u3073\u304c\u3093\u9032\u884c\" width=\"488\" height=\"451\" \/><\/a> <a href=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/2-14.jpg\"><img loading=\"lazy\" decoding=\"async\" class=\"size-full wp-image-3046 aligncenter\" src=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/2-14.jpg\" alt=\"\u7c73\u56fdFDA\u3067\u627f\u8a8d\u3055\u308c\u305f\u4ee3\u8868\u7684\u306aVEGF\u7d4c\u8def\u963b\u5bb3\u5264\" width=\"982\" height=\"348\" \/><\/a><\/p>\n<h4>\u5897\u6b96\u56e0\u5b50\u304a\u3088\u3073\u5897\u6b96\u56e0\u5b50\u53d7\u5bb9\u4f53\u306e\u691c\u51fa<\/h4>\n<p>&nbsp;<\/p>\n<p><a href=\"http:\/\/www.thermofisher.com\/VEGF?CID=bid_pca_aup_r04_jp_cp0000_pjt0000_bid00000_0so_blg_op_awa_oc_s00_ab12_Social_LAB\" target=\"_blank\" rel=\"noopener\">\u5f53\u793e\u306f\u3001VEGF\u304a\u3088\u3073VEGFR\u30d5\u30a1\u30df\u30ea\u30fc\u30bf\u30f3\u30d1\u30af\u8cea\u306a\u3089\u3073\u306b\u4ed6\u306e\u5897\u6b96\u56e0\u5b50\u30b9\u30fc\u30d1\u30fc\u30d5\u30a1\u30df\u30ea\u30fc\u30bf\u30f3\u30d1\u30af\u8cea\u3092\u691c\u51fa\u3059\u308b\u305f\u3081\u306e\u5e45\u5e83\u3044\u6297\u4f53\u3092\u63d0\u4f9b\u3057\u3066\u3044\u307e\u3059\u3002\u88fd\u54c1\u306b\u95a2\u3059\u308b\u8a73\u3057\u3044\u60c5\u5831\u306f \u3053\u3061\u3089\u3092\u3054\u89a7\u304f\u3060\u3055\u3044\u3002<\/a><\/p>\n<p><a href=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/1-64.jpg\"><img loading=\"lazy\" decoding=\"async\" class=\"size-full wp-image-3047 aligncenter\" src=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/1-64.jpg\" alt=\"VEGF Receptor 2 \/Flk-1 Mouse Monoclonal Antibody \uff08A\uff09\" width=\"1002\" height=\"824\" \/><\/a><\/p>\n<h4>\u30c8\u30e9\u30f3\u30b9\u30d5\u30a9\u30fc\u30df\u30f3\u30b0\u5897\u6b96\u56e0\u5b50-\u03b2<\/h4>\n<p>\u53d7\u5bb9\u4f53\u578b\u30c1\u30ed\u30b7\u30f3\u30ad\u30ca\u30fc\u30bc\u7d4c\u8def\u306b\u52a0\u3048\u3066\u3001\u30c8\u30e9\u30f3\u30b9\u30d5\u30a9\u30fc\u30df\u30f3\u30b0\u5897\u6b96\u56e0\u5b50\u30d5\u30a1\u30df\u30ea\u30fc\u306b\u3082\u3001\u4ed6\u306e\u4e3b\u8981\u306a\u30b7\u30b0\u30ca\u30eb\u4f1d\u9054\u30cd\u30c3\u30c8\u30ef\u30fc\u30af\u304c\u542b\u307e\u308c\u3066\u304a\u308a\u3001\u305d\u308c\u304c\u969c\u5bb3\u3055\u308c\u308b\u3068\u3001\u304c\u3093\u7d30\u80de\u306e\u5897\u6b96\u304c\u4fc3\u9032\u3055\u308c\u308b\u53ef\u80fd\u6027\u304c\u3042\u308a\u307e\u3059\uff08\u56f32.5\uff09\u3002\u30c8\u30e9\u30f3\u30b9\u30d5\u30a9\u30fc\u30df\u30f3\u30b0\u5897\u6b96\u56e0\u5b50\uff08TGF-\u03b2\uff09\u306f\u3001\u69cb\u9020\u7684\u306b\u30db\u30e2\u4e8c\u91cf\u4f53\u3092\u5f62\u6210\u3059\u308b\u30b5\u30a4\u30c8\u30ab\u30a4\u30f3\u306e\u30d5\u30a1\u30df\u30ea\u30fc\u3067\u3059\u3002\u54fa\u4e73\u985e\u30a2\u30a4\u30bd\u30d5\u30a9\u30fc\u30e0\u306b\u306f\u3001TGF-\u03b21\u3001TGF-\u03b22\u3001\u304a\u3088\u3073TGF-\u03b23\u304c\u3042\u308a\u3001\u95a2\u9023\u3059\u308b\u30bb\u30ea\u30f3\/\u30b9\u30ec\u30aa\u30cb\u30f3\u53d7\u5bb9\u4f53\u3068\u3068\u3082\u306b\u7d30\u80de\u5897\u6b96\u3001\u8840\u7ba1\u65b0\u751f\u3001\u514d\u75ab\u53cd\u5fdc\u3001\u30a2\u30dd\u30c8\u30fc\u30b7\u30b9\u3001\u304a\u3088\u3073\u4ed6\u306e\u6a5f\u80fd\u3092\u542b\u3080\u8907\u6570\u306e\u751f\u7269\u5b66\u7684\u30d7\u30ed\u30bb\u30b9\u3092\u5236\u5fa1\u3057\u3066\u3044\u307e\u3059\u3002TGF-\u03b2\u30b7\u30b0\u30ca\u30eb\u4f1d\u9054\u306e\u8abf\u7bc0\u4e0d\u5168\u306f\u3001\u5275\u50b7\u6cbb\u7652\u306e\u7570\u5e38\u3001\u7d44\u7e54\u7dda\u7dad\u5316\u3001\u5fc3\u8840\u7ba1\u75be\u60a3\u3001\u304c\u3093\u3001\u81ea\u5df1\u514d\u75ab\u75be\u60a3\u3001\u304a\u3088\u3073\u4ed6\u306e\u969c\u5bb3\u306b\u95a2\u4fc2\u3057\u307e\u3059\u3002SMAD\u306f\u3001\u9032\u5316\u7684\u306b\u4fdd\u5b58\u3055\u308c\u305f\u7d30\u80de\u5185\u30bf\u30f3\u30d1\u30af\u8cea\u3067\u3001\u30bb\u30ea\u30f3\/\u30b9\u30ec\u30aa\u30cb\u30f3\u30ad\u30ca\u30fc\u30bc\u53d7\u5bb9\u4f53\u306b\u3088\u3063\u3066\u6d3b\u6027\u5316\u3055\u308c\u3001\u6838\u79fb\u884c\u304c\u751f\u3058\u3001\u305d\u308c\u306b\u7d9a\u304dTGF-\u03b2\u30b7\u30b0\u30ca\u30eb\u4f1d\u9054\u306e\u8ee2\u5199\u5236\u5fa1\u56e0\u5b50\u3068\u3057\u3066\u6a5f\u80fd\u3057\u307e\u3059\u00a0<sup>*31,32<\/sup>\u3002<\/p>\n<p><a href=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/1-65.jpg\"><img loading=\"lazy\" decoding=\"async\" class=\"size-full wp-image-3048 aligncenter\" src=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/1-65.jpg\" alt=\"\u4e3b\u8981\u306a\u30b7\u30b0\u30ca\u30eb\u4f1d\u9054\u7d4c\u8def\" width=\"488\" height=\"634\" \/><\/a> <a href=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/2-15.jpg\"><img loading=\"lazy\" decoding=\"async\" class=\"size-full wp-image-3049 aligncenter\" src=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/2-15.jpg\" alt=\"SMAD2 Mouse Monoclonal Antibody (5G7)\u3000\" width=\"488\" height=\"784\" \/><\/a><\/p>\n<h4>\u304c\u3093\u306b\u304a\u3051\u308b\u7570\u5e38\u306a\u30b7\u30b0\u30ca\u30eb\u4f1d\u9054<\/h4>\n<p>\u56f32.6\u306b\u793a\u3057\u305f\u30b7\u30b0\u30ca\u30eb\u4f1d\u9054\u30ab\u30b9\u30b1\u30fc\u30c9\u306f\u3001\u6b63\u5e38\u306a\u7d30\u80de\u30d7\u30ed\u30bb\u30b9\u3092\u5236\u5fa1\u3057\u3066\u3044\u308b\u8907\u6570\u306e\u7d4c\u8def\u304c\u60aa\u6027\u7d30\u80de\u306e\u5897\u6b96\u306b\u3082\u5bc4\u4e0e\u3057\u3066\u3044\u308b\u3053\u3068\u3092\u793a\u3057\u3066\u3044\u307e\u3059\u3002\u6210\u9577\u304a\u3088\u3073\u5897\u6b96\u306b\u95a2\u4e0e\u3059\u308b\u91cd\u8981\u306a\u7d4c\u8def\u306b\u306f\u3001\u3053\u308c\u3089\u306b\u9650\u5b9a\u3055\u308c\u307e\u305b\u3093\u304c\u3001PI3K\/Akt\/mTor\u3001Ras\/Raf\/MEK\u3001\u304a\u3088\u3073Wnt\/\u03b2-\u30ab\u30c6\u30cb\u30f3\u306e\u30b7\u30b0\u30ca\u30eb\u4f1d\u9054\u7d4c\u8def\u304c\u3042\u308a\u307e\u3059\u00a0<sup>*33\u201335<\/sup>\u3002<br \/>\n\u3053\u308c\u3089\u306e\u7d4c\u8def\u306f\u3001\u304c\u3093\u306e\u5897\u6b96\u304a\u3088\u3073\u6210\u9577\u3092\u5236\u5fa1\u3059\u308b\u4ed6\u306b\u3001\u96c6\u5408\u7684\u306b\u8907\u6570\u306e\u751f\u7406\u7684\u30d7\u30ed\u30bb\u30b9\u3092\u8abf\u7bc0\u3057\u3066\u3044\u307e\u3059\u00a0<sup>*36\u00a0<\/sup>\u3002<\/p>\n<ul>\n<li>\u30a2\u30dd\u30c8\u30fc\u30b7\u30b9<\/li>\n<li>\u7d30\u80de\u5468\u671f\u8abf\u7bc0<\/li>\n<li>DNA\u306e\u7dad\u6301<\/li>\n<li>\u907a\u4f1d\u5b50\u8ee2\u5199<\/li>\n<li>\u751f\u5b58<\/li>\n<li>\u4ee3\u8b1d<\/li>\n<li>\u8840\u7ba1\u65b0\u751f<\/li>\n<li>\u5275\u50b7\u6cbb\u7652<\/li>\n<li>\u7d30\u80de\u904a\u8d70<\/li>\n<li>\u5206\u5316<\/li>\n<li>\u305d\u306e\u4ed6\u306e\u6a5f\u80fd<\/li>\n<\/ul>\n<p><a href=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/1-66.jpg\"><img loading=\"lazy\" decoding=\"async\" class=\"size-full wp-image-3050 aligncenter\" src=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/1-66.jpg\" alt=\"\u304c\u3093\u7d30\u80de\u306e\u5897\u6b96\u3092\u4fc3\u9032\u3059\u308b\u91cd\u8981\u306a\u30b7\u30b0\u30ca\u30eb\u4f1d\u9054\u7d4c\u8def\" width=\"483\" height=\"719\" \/><\/a> <a href=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/2-16.jpg\"><img loading=\"lazy\" decoding=\"async\" class=\"size-full wp-image-3051 aligncenter\" src=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/2-16.jpg\" alt=\"Ki-67 Rabbit Polyclonal Antibody\" width=\"486\" height=\"937\" \/><\/a><\/p>\n<h4>\u00a0\u6297\u4f53\uff1a\u304c\u3093\u7814\u7a76\u306e\u305f\u3081\u306e\u5f37\u529b\u306a\u30c4\u30fc\u30eb<\/h4>\n<p>\u5f53\u793e\u3067\u306f74,000\u7a2e\u985e\u4ee5\u4e0a\u306e\u4e00\u6b21\u6297\u4f53\u304a\u3088\u3073\u4e8c\u6b21\u6297\u4f53\u3092\u63d0\u4f9b\u3057\u3066\u304a\u308a\u307e\u3059\u3002<a href=\"http:\/\/www.thermofisher.com\/spectraviewer?CID=bid_pca_aup_r04_jp_cp0000_pjt0000_bid00000_0so_blg_op_awa_oc_s00_ab12_Social_LAB\" target=\"_blank\" rel=\"noopener\">\u30de\u30eb\u30c1\u30ab\u30e9\u30fc\u6297\u4f53\u30d1\u30cd\u30eb\u306b\u5fc5\u8981\u3068\u3055\u308c\u308b\u30a2\u30d7\u30ea\u30b1\u30fc\u30b7\u30e7\u30f3\u306e\u305f\u3081\u306eSpectraViewer\u306b\u3064\u3044\u3066\u306f\u3053\u3061\u3089\u3092\u3054\u89a7\u304f\u3060\u3055\u3044\u3002<\/a><\/p>\n<h2>\u3010\u7121\u6599\u30c0\u30a6\u30f3\u30ed\u30fc\u30c9\u3011\u304c\u3093\u5897\u6b96\u30b7\u30b0\u30ca\u30eb\u4f1d\u9054\u7d4c\u8def\u306e\u63a2\u7d22\u30ac\u30a4\u30c9\u30d6\u30c3\u30af<\/h2>\n<p>\u5f53\u8a18\u4e8b\u306f\u3001\u304c\u3093\u5897\u6b96\u30b7\u30b0\u30ca\u30eb\u4f1d\u9054\u7d4c\u8def\u306e\u63a2\u7d22\u30ac\u30a4\u30c9\u30d6\u30c3\u30af\u304b\u3089\u306e\u629c\u7c8b\u3067\u3059\u3002\u4e0b\u8a18\u306e\u5185\u5bb9\u3092\u542b\u3080PDF\u306f\u4e0b\u8a18\u304b\u3089\u7121\u6599\u3067\u30c0\u30a6\u30f3\u30ed\u30fc\u30c9\u9802\u3051\u307e\u3059\u3002<\/p>\n<p>\uff5e\u4e3b\u306a\u5185\u5bb9\uff5e<\/p>\n<ol>\n<li>\u304c\u3093\u6982\u8ad6<\/li>\n<li>\u304c\u3093\u5897\u6b96\u30b7\u30b0\u30ca\u30eb\u4f1d\u9054<\/li>\n<li>PI3K\/Akt\/mTOR\u30b7\u30b0\u30ca\u30eb\u4f1d\u9054\u7d4c\u8def<\/li>\n<li>Ras\/Raf\/MEK\/ERK(MAPK)\u30b7\u30b0\u30ca\u30eb\u4f1d\u9054\u7d4c\u8def<\/li>\n<li>Wnt\/\u03b2-\u30ab\u30c6\u30cb\u30f3 \u30b7\u30b0\u30ca\u30eb\u4f1d\u9054\u7d4c\u8def<\/li>\n<li>\u6297\u4f53\uff1a\u304c\u3093\u7814\u7a76\u306e\u305f\u3081\u306e\u5354\u529b\u306a\u30c4\u30fc\u30eb<\/li>\n<\/ol>\n<p><strong><a class=\"btn btn-red\" href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/global\/forms\/antibody-cancer-guidebook-form.html?CID=bid_pca_aup_r04_jp_cp0000_pjt0000_bid00000_0so_blg_op_awa_oc_s00_ab12_Social_LAB\" target=\"_blank\" rel=\"noopener\">\u7121\u6599\u30ac\u30a4\u30c9\u30d6\u30c3\u30af\u3092\u30c0\u30a6\u30f3\u30ed\u30fc\u30c9\u3059\u308b<\/a><\/strong><\/p>\n<h2>\u3010\u7121\u6599\u30c0\u30a6\u30f3\u30ed\u30fc\u30c9\u3011\u304c\u3093\u7814\u7a76\u3092\u4fc3\u9032\u3055\u305b\u308b\u907a\u4f1d\u5b50\u89e3\u6790\u6280\u8853\u30cf\u30f3\u30c9\u30d6\u30c3\u30af<\/h2>\n<p>\u307e\u305f\u3001\u8907\u6570\u306e\u304c\u3093\u7814\u7a76\u9818\u57df\u306b\u304a\u3051\u308b\u8208\u5473\u6df1\u3044\u6700\u65b0\u306e\u767a\u898b\u3092\u53ef\u80fd\u306b\u3059\u308b\u907a\u4f1d\u5b50\u89e3\u6790\u6280\u8853\u3092\u7d39\u4ecb\u3059\u308b\u30cf\u30f3\u30c9\u30d6\u30c3\u30af\u3082\u914d\u5e03\u3057\u3066\u3044\u307e\u3059\u3002\u4f75\u305b\u3066\u3054\u3089\u3093\u304f\u3060\u3055\u3044\u3002<\/p>\n<p><a class=\"btn btn-red\" href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/global\/forms\/cancer-genetic-tech-ebook-download.html?CID=bid_pca_aup_r04_jp_cp0000_pjt0000_bid00000_0so_blg_op_awa_oc_s00_ab12_Social_LAB\" target=\"_blank\" rel=\"noopener\">\u7121\u6599\u30cf\u30f3\u30c9\u30d6\u30c3\u30af\u3092\u30c0\u30a6\u30f3\u30ed\u30fc\u30c9\u3059\u308b<\/a><\/p>\n<p><span style=\"font-size: 8pt\">\u53c2\u8003\u6587\u732e\uff1a<br \/>\n1. Chen HZ, Tsai SY, Leone G (2009) Emerging roles of E2Fs in cancer: an exit from cell cycle control.\u00a0Nat Rev Cancer 9(11):785\u2013797.<br \/>\n2. Hanahan D, Weinberg RA (2011) Hallmarks of cancer: the next generation. Cell 144(5):646\u2013674.<br \/>\n3. Golias CH, Charalabopoulos A, Charalabopoulos K (2004) Cell proliferation and cell cycle control: a mini\u00a0review. Int J Clin Pract 58(12):1134\u20131141.<br \/>\n4. Vogelstein B, Prives C (2009) The rise of p53. Nature Publishing Group website. http:\/\/www.nature.com\/reviews\/posters\/p53\/index.html (second panel)<br \/>\n5. Olivier M, Hollstein M, Hainaut P (2010) TP53 mutations in human cancers: origins, consequences, and\u00a0clinical use. Cold Spring Harb Perspect Biol 2(1):a001008.<br \/>\n6. Kamal A, Boehm MF, Burrows FJ (2004) Therapeutic and diagnostic implications of HSP90 activation.\u00a0Trends Mol Med 10(6):283\u2013290.<br \/>\n7. Scaltriti M, Baselga J (2006) The epidermal growth factor receptor pathway: a model for targeted therapy.\u00a0Clin Cancer Res 12(18):5268\u20135272.<br \/>\n8. Frederick L, Wang XY, Eley G, James CD (2000) Diversity and frequency of epidermal growth factor receptor\u00a0mutations in human glioblastomas. Cancer Res 60(5):1383\u20131387.<br \/>\n9. Li R, Pourpak A, Morris SW (2009) Inhibition of the insulin-like growth factor-1 receptor (IGF1R) tyrosine kinase as a novel cancer therapy approach. J Med Chem 52(16):4981\u20135004.<br \/>\n10. Ehnman M, \u00d6stman A (2014) Therapeutic targeting of platelet-derived growth factor receptors in solid\u00a0tumors. Expert Opin Investig Drugs 23(2):211\u2013226.<br \/>\n11. Dieci MV, Arnedos M, Andre F, Soria JC (2013) Fibroblast growth factor receptor inhibitors as a cancer\u00a0treatment: from a biologic rationale to medical perspectives. Cancer Discov 3(3):264\u2013279.<br \/>\n12. National Cancer Institute website (2011) FDA approval for gefitinib. http:\/\/www.cancer.gov\/cancertopics\/druginfo\/fda-gefitinib<br \/>\n13. Bristol-Myers Squibb (2013) Erbitux (cetuximab) prescribing information. http:\/\/packageinserts.bms.com\/pi\/pi_erbitux.pdf<br \/>\n14. Genentech (2014) Tarceva (erlotinib) prescribing info. http:\/\/www.gene.com\/download\/pdf\/tarceva_prescribing.pdf<br \/>\n15. Amgen (2014) Vectibix (panitumumab) prescribing info. http:\/\/pi.amgen.com\/united_states\/vectibix\/vectibix_pi.pdf<br \/>\n16. GlaxoSmithKline (2014) Tykerb (lapatinib) prescribing information. https:\/\/www.gsksource.com\/gskprm\/htdocs\/documents\/tykerb-pi-pil.pdf<br \/>\n17. Genentech (2014) Herceptin (trastuzumab) prescribing information. http:\/\/www.gene.com\/download\/pdf\/herceptin_prescribing.pdf<br \/>\n18. Genentech (2013) Perjeta (pertuzumab) prescribing information. http:\/\/www.gene.com\/download\/pdf\/perjeta_prescribing.pdf<br \/>\n19. Genentech (2014) Kadcycla (ado-trastuzumab emtansine) prescribing information. http:\/\/www.gene.com\/download\/pdf\/kadcyla_prescribing.pdf<br \/>\n20. Grothey A, Galanis E (2009) Targeting angiogenesis: progress with anti-VEGF treatment with large molecules. Nat Rev Clin Oncol 6(9):507\u2013518.<br \/>\n21. National Cancer Institute website (2011) Angiogenesis inhibitors. http:\/\/www.cancer.gov\/cancertopics\/factsheet\/Therapy\/angiogenesis-inhibitors<br \/>\n22. Liang Y, Brekken RA, Hyder SM (2006) Vascular endothelial growth factor induces proliferation of breast\u00a0cancer cells and inhibits the anti-proliferative activity of anti-hormones. Endocr Relat Cancer 13(3):905\u2013919.<br \/>\n23. Genetech (2014) Avastin (bevacizumab) prescribing information. http:\/\/www.gene.com\/download\/pdf\/avastin_prescribing.pdf<br \/>\n24. Bayer HealthCare Pharmaceuticals (2013) Nexavar (sorafenib) prescribing information. http:\/\/labeling.bayerhealthcare.com\/html\/products\/pi\/Nexavar_PI.pdf<br \/>\n25. Pfizer Laboratories (2014) Sutent (sunitinib malate) prescribing information. http:\/\/labeling.pfizer.com\/ShowLabeling.aspx?id=607<br \/>\n26. GlaxoSmithKline (2014) Votrient (pazopanib) prescribing information. https:\/\/www.gsksource.com\/gskprm\/htdocs\/documents\/votrient-pi-mg.pdf<br \/>\n27. AstraZeneca (2014) Caprelsa (vandetanib) prescribing information. http:\/\/www.caprelsahcp.com\/content\/dam\/physician-services\/us\/201-caprelsahcp-com\/home\/caprelsa.pdf<br \/>\n28. Pfizer Laboratories (2014) Inlyta (axitinib) prescribing information. http:\/\/labeling.pfizer.com\/ShowLabeling.aspx?id=759<br \/>\n29. Sanofi-Aventis (2014) Zaltrap (ziv-aflibercept) prescribing information. http:\/\/products.sanofi.us\/zaltrap\/zaltrap.html<br \/>\n30. Eli Lilly and Company (2014) Cyramza (ramucirumab) prescribing information. http:\/\/pi.lilly.com\/us\/cyramzapi.pdf<br \/>\n31. Samanta D, Datta PK (2012) Alterations in the Smad pathway in human cancers. Front Biosci (Landmark\u00a0Ed) 17:1281\u20131293. http:\/\/www.ncbi.nlm.nih.gov\/pmc\/articles\/PMC4281477\/<br \/>\n32. Derynck R, Zhang YE (2003) Smad-dependent and Smad-independent pathways in TGF-beta family\u00a0signalling. Nature 425(6958):577\u2013584. http:\/\/www.nature.com\/nature\/journal\/v425\/n6958\/full\/nature02006.html<br \/>\n33. CancerLink.ru website (2013) New molecular biomarkers candidates for the development of multiparametric\u00a0platforms for hepatocellular carcinoma diagnosis, prognosis and personalised therapy. http:\/\/cancerlink.ru\/ennew-molecular-biomarkers-for-hepatocellular-carcinoma-diagnosis.html<br \/>\n34. Le PN, McDermott JD, Jimeno A (2015) Targeting the Wnt pathway in human cancers: therapeutic targeting\u00a0with a focus on OMP-54F28. Pharmacol Ther 146C:1\u201311.<br \/>\n35. LoPiccolo J, Blumenthal GM, Bernstein WB, Dennis PA (2008) Targeting the PI3K\/Akt\/mTOR pathway:\u00a0effective combinations and clinical considerations. Drug Resist Updat 11(1\u20132):32\u201350. http:\/\/www.ncbi.nlm.nih.gov\/pmc\/articles\/PMC2442829\/pdf\/nihms51320.pdf<br \/>\n36. Witsch E, Sela M, Yarden Y (2010) Roles for growth factors in cancer progression. Physiology 25(2):85\u2013101.<br \/>\n<\/span><\/p>\n<p>&nbsp;<\/p>\n<p>\u7814\u7a76\u7528\u306b\u306e\u307f\u4f7f\u7528\u3067\u304d\u307e\u3059\u3002\u8a3a\u65ad\u76ee\u7684\u304a\u3088\u3073\u305d\u306e\u624b\u7d9a\u304d\u4e0a\u3067\u306e\u4f7f\u7528\u306f\u3067\u304d\u307e\u305b\u3093\u3002<\/p>\n","protected":false},"excerpt":{"rendered":"<p>\u304c\u3093\u7d30\u80de\u306e\u5897\u6b96 \u907a\u4f1d\u5b50\u5909\u7570\u306e\u84c4\u7a4d\u306f\u3001\u6700\u7d42\u7684\u306b\u7d30\u80de\u5468\u671f\u8abf\u7bc0\u306b\u5fc5\u8981\u3068\u3055\u308c\u308b\u30e1\u30ab\u30cb\u30ba\u30e0\u3092\u59a8\u3052\u307e\u3059\u3002\u6b63\u5e38\u306a\u72b6\u614b\u3067\u306f\u3001\u5897\u6b96\u30b7\u30b0\u30ca\u30eb\u306e\u7523\u751f\u304a\u3088\u3073\u4f1d\u64ad\u306a\u3089\u3073\u306b\u7d30\u80de\u5897\u6b96\u304c\u9ad8\u5ea6\u306b\u8abf\u7bc0\u3055\u308c\u3066\u3044\u307e\u3059\u3002\u5897\u6b96\u30d7\u30ed\u30bb\u30b9\u306e\u53b3\u5bc6\u306a\u5236\u5fa1\u306f\u3001\u5065\u5168\u306a\u7d44\u7e54\u306e\u69cb<\/p>\n","protected":false},"author":988,"featured_media":3902,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_monsterinsights_skip_tracking":false,"_genesis_hide_title":false,"_genesis_hide_breadcrumbs":false,"_genesis_hide_singular_image":false,"_genesis_hide_footer_widgets":false,"_genesis_custom_body_class":"","_genesis_custom_post_class":"","_genesis_layout":"","_jetpack_newsletter_access":"","_jetpack_dont_email_post_to_subs":false,"_jetpack_newsletter_tier_id":0,"_jetpack_memberships_contains_paywalled_content":false,"_jetpack_feature_clip_id":0,"_jetpack_memberships_contains_paid_content":false,"footnotes":"","jetpack_post_was_ever_published":false},"categories":[156],"tags":[83,32],"division":[],"class_list":{"0":"post-952","1":"post","2":"type-post","3":"status-publish","4":"format-standard","5":"has-post-thumbnail","7":"category-mol-bio","8":"tag-cancer","9":"tag-antibody","10":"entry"},"_selected_authors":"","_selected_reviewers":"","acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v27.8 (Yoast SEO v27.8) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>\u3010\u3044\u307e\u3055\u3089\u805e\u3051\u306a\u3044\u304c\u3093\u306e\u57fa\u790e 7\u3011\u304c\u3093\u5897\u6b96\u30b7\u30b0\u30ca\u30eb\u3068\u30bf\u30fc\u30b2\u30c6\u30a3\u30f3\u30b0 - Learning at the Bench<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/cancer7\/\" \/>\n<meta property=\"og:locale\" content=\"ja_JP\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"\u3010\u3044\u307e\u3055\u3089\u805e\u3051\u306a\u3044\u304c\u3093\u306e\u57fa\u790e 7\u3011\u304c\u3093\u5897\u6b96\u30b7\u30b0\u30ca\u30eb\u3068\u30bf\u30fc\u30b2\u30c6\u30a3\u30f3\u30b0\" \/>\n<meta property=\"og:description\" content=\"\u304c\u3093\u7d30\u80de\u306e\u5897\u6b96 \u907a\u4f1d\u5b50\u5909\u7570\u306e\u84c4\u7a4d\u306f\u3001\u6700\u7d42\u7684\u306b\u7d30\u80de\u5468\u671f\u8abf\u7bc0\u306b\u5fc5\u8981\u3068\u3055\u308c\u308b\u30e1\u30ab\u30cb\u30ba\u30e0\u3092\u59a8\u3052\u307e\u3059\u3002\u6b63\u5e38\u306a\u72b6\u614b\u3067\u306f\u3001\u5897\u6b96\u30b7\u30b0\u30ca\u30eb\u306e\u7523\u751f\u304a\u3088\u3073\u4f1d\u64ad\u306a\u3089\u3073\u306b\u7d30\u80de\u5897\u6b96\u304c\u9ad8\u5ea6\u306b\u8abf\u7bc0\u3055\u308c\u3066\u3044\u307e\u3059\u3002\u5897\u6b96\u30d7\u30ed\u30bb\u30b9\u306e\u53b3\u5bc6\u306a\u5236\u5fa1\u306f\u3001\u5065\u5168\u306a\u7d44\u7e54\u306e\u69cb\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/cancer7\/\" \/>\n<meta property=\"og:site_name\" content=\"Learning at the Bench\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/ThermoFisherJapan\" \/>\n<meta property=\"article:published_time\" content=\"2019-01-10T00:00:00+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2025-02-28T05:48:18+00:00\" \/>\n<meta property=\"og:image\" content=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/17107e39d57b8bc5e797aba6ae6904eb-1.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"900\" \/>\n\t<meta property=\"og:image:height\" content=\"473\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"LATB Staff\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:creator\" content=\"@ThermoFisherJP\" \/>\n<meta name=\"twitter:site\" content=\"@ThermoFisherJP\" \/>\n<meta name=\"twitter:label1\" content=\"\u57f7\u7b46\u8005\" \/>\n\t<meta name=\"twitter:data1\" content=\"LATB Staff\" \/>\n\t<meta name=\"twitter:label2\" content=\"\u63a8\u5b9a\u8aad\u307f\u53d6\u308a\u6642\u9593\" \/>\n\t<meta name=\"twitter:data2\" content=\"27\u5206\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/cancer7\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/cancer7\\\/\"},\"author\":{\"name\":\"LATB Staff\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#\\\/schema\\\/person\\\/00a095a01d54afcdf9457465feb04f7d\"},\"headline\":\"\u3010\u3044\u307e\u3055\u3089\u805e\u3051\u306a\u3044\u304c\u3093\u306e\u57fa\u790e 7\u3011\u304c\u3093\u5897\u6b96\u30b7\u30b0\u30ca\u30eb\u3068\u30bf\u30fc\u30b2\u30c6\u30a3\u30f3\u30b0\",\"datePublished\":\"2019-01-10T00:00:00+00:00\",\"dateModified\":\"2025-02-28T05:48:18+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/cancer7\\\/\"},\"wordCount\":748,\"commentCount\":0,\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/cancer7\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2019\\\/07\\\/17107e39d57b8bc5e797aba6ae6904eb-1.jpg\",\"keywords\":[\"\u304c\u3093\",\"\u6297\u4f53\"],\"articleSection\":[\"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023\"],\"inLanguage\":\"ja\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/cancer7\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/cancer7\\\/\",\"url\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/cancer7\\\/\",\"name\":\"\u3010\u3044\u307e\u3055\u3089\u805e\u3051\u306a\u3044\u304c\u3093\u306e\u57fa\u790e 7\u3011\u304c\u3093\u5897\u6b96\u30b7\u30b0\u30ca\u30eb\u3068\u30bf\u30fc\u30b2\u30c6\u30a3\u30f3\u30b0 - Learning at the Bench\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/cancer7\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/cancer7\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2019\\\/07\\\/17107e39d57b8bc5e797aba6ae6904eb-1.jpg\",\"datePublished\":\"2019-01-10T00:00:00+00:00\",\"dateModified\":\"2025-02-28T05:48:18+00:00\",\"author\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#\\\/schema\\\/person\\\/00a095a01d54afcdf9457465feb04f7d\"},\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/cancer7\\\/#breadcrumb\"},\"inLanguage\":\"ja\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/cancer7\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"ja\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/cancer7\\\/#primaryimage\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2019\\\/07\\\/17107e39d57b8bc5e797aba6ae6904eb-1.jpg\",\"contentUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2019\\\/07\\\/17107e39d57b8bc5e797aba6ae6904eb-1.jpg\",\"width\":900,\"height\":473},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/cancer7\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"\u3010\u3044\u307e\u3055\u3089\u805e\u3051\u306a\u3044\u304c\u3093\u306e\u57fa\u790e 7\u3011\u304c\u3093\u5897\u6b96\u30b7\u30b0\u30ca\u30eb\u3068\u30bf\u30fc\u30b2\u30c6\u30a3\u30f3\u30b0\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#website\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/\",\"name\":\"Learning at the Bench\",\"description\":\"\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"ja\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#\\\/schema\\\/person\\\/00a095a01d54afcdf9457465feb04f7d\",\"name\":\"LATB Staff\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"ja\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/8803277856c8b753feb4217dff0f9953327452df1a615c3c88b2f9864efb2ddd?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/8803277856c8b753feb4217dff0f9953327452df1a615c3c88b2f9864efb2ddd?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/8803277856c8b753feb4217dff0f9953327452df1a615c3c88b2f9864efb2ddd?s=96&d=mm&r=g\",\"caption\":\"LATB Staff\"},\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/author\\\/latbstaff\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"\u3010\u3044\u307e\u3055\u3089\u805e\u3051\u306a\u3044\u304c\u3093\u306e\u57fa\u790e 7\u3011\u304c\u3093\u5897\u6b96\u30b7\u30b0\u30ca\u30eb\u3068\u30bf\u30fc\u30b2\u30c6\u30a3\u30f3\u30b0 - Learning at the Bench","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/cancer7\/","og_locale":"ja_JP","og_type":"article","og_title":"\u3010\u3044\u307e\u3055\u3089\u805e\u3051\u306a\u3044\u304c\u3093\u306e\u57fa\u790e 7\u3011\u304c\u3093\u5897\u6b96\u30b7\u30b0\u30ca\u30eb\u3068\u30bf\u30fc\u30b2\u30c6\u30a3\u30f3\u30b0","og_description":"\u304c\u3093\u7d30\u80de\u306e\u5897\u6b96 \u907a\u4f1d\u5b50\u5909\u7570\u306e\u84c4\u7a4d\u306f\u3001\u6700\u7d42\u7684\u306b\u7d30\u80de\u5468\u671f\u8abf\u7bc0\u306b\u5fc5\u8981\u3068\u3055\u308c\u308b\u30e1\u30ab\u30cb\u30ba\u30e0\u3092\u59a8\u3052\u307e\u3059\u3002\u6b63\u5e38\u306a\u72b6\u614b\u3067\u306f\u3001\u5897\u6b96\u30b7\u30b0\u30ca\u30eb\u306e\u7523\u751f\u304a\u3088\u3073\u4f1d\u64ad\u306a\u3089\u3073\u306b\u7d30\u80de\u5897\u6b96\u304c\u9ad8\u5ea6\u306b\u8abf\u7bc0\u3055\u308c\u3066\u3044\u307e\u3059\u3002\u5897\u6b96\u30d7\u30ed\u30bb\u30b9\u306e\u53b3\u5bc6\u306a\u5236\u5fa1\u306f\u3001\u5065\u5168\u306a\u7d44\u7e54\u306e\u69cb","og_url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/cancer7\/","og_site_name":"Learning at the Bench","article_publisher":"https:\/\/www.facebook.com\/ThermoFisherJapan","article_published_time":"2019-01-10T00:00:00+00:00","article_modified_time":"2025-02-28T05:48:18+00:00","og_image":[{"width":900,"height":473,"url":"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/17107e39d57b8bc5e797aba6ae6904eb-1.jpg","type":"image\/jpeg"}],"author":"LATB Staff","twitter_card":"summary_large_image","twitter_creator":"@ThermoFisherJP","twitter_site":"@ThermoFisherJP","twitter_misc":{"\u57f7\u7b46\u8005":"LATB Staff","\u63a8\u5b9a\u8aad\u307f\u53d6\u308a\u6642\u9593":"27\u5206"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/cancer7\/#article","isPartOf":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/cancer7\/"},"author":{"name":"LATB Staff","@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#\/schema\/person\/00a095a01d54afcdf9457465feb04f7d"},"headline":"\u3010\u3044\u307e\u3055\u3089\u805e\u3051\u306a\u3044\u304c\u3093\u306e\u57fa\u790e 7\u3011\u304c\u3093\u5897\u6b96\u30b7\u30b0\u30ca\u30eb\u3068\u30bf\u30fc\u30b2\u30c6\u30a3\u30f3\u30b0","datePublished":"2019-01-10T00:00:00+00:00","dateModified":"2025-02-28T05:48:18+00:00","mainEntityOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/cancer7\/"},"wordCount":748,"commentCount":0,"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/cancer7\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/17107e39d57b8bc5e797aba6ae6904eb-1.jpg","keywords":["\u304c\u3093","\u6297\u4f53"],"articleSection":["\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023"],"inLanguage":"ja","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/cancer7\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/cancer7\/","url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/cancer7\/","name":"\u3010\u3044\u307e\u3055\u3089\u805e\u3051\u306a\u3044\u304c\u3093\u306e\u57fa\u790e 7\u3011\u304c\u3093\u5897\u6b96\u30b7\u30b0\u30ca\u30eb\u3068\u30bf\u30fc\u30b2\u30c6\u30a3\u30f3\u30b0 - Learning at the Bench","isPartOf":{"@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/cancer7\/#primaryimage"},"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/cancer7\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/17107e39d57b8bc5e797aba6ae6904eb-1.jpg","datePublished":"2019-01-10T00:00:00+00:00","dateModified":"2025-02-28T05:48:18+00:00","author":{"@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#\/schema\/person\/00a095a01d54afcdf9457465feb04f7d"},"breadcrumb":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/cancer7\/#breadcrumb"},"inLanguage":"ja","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/cancer7\/"]}]},{"@type":"ImageObject","inLanguage":"ja","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/cancer7\/#primaryimage","url":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/17107e39d57b8bc5e797aba6ae6904eb-1.jpg","contentUrl":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/17107e39d57b8bc5e797aba6ae6904eb-1.jpg","width":900,"height":473},{"@type":"BreadcrumbList","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/cancer7\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/"},{"@type":"ListItem","position":2,"name":"\u3010\u3044\u307e\u3055\u3089\u805e\u3051\u306a\u3044\u304c\u3093\u306e\u57fa\u790e 7\u3011\u304c\u3093\u5897\u6b96\u30b7\u30b0\u30ca\u30eb\u3068\u30bf\u30fc\u30b2\u30c6\u30a3\u30f3\u30b0"}]},{"@type":"WebSite","@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#website","url":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/","name":"Learning at the Bench","description":"","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"ja"},{"@type":"Person","@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#\/schema\/person\/00a095a01d54afcdf9457465feb04f7d","name":"LATB Staff","image":{"@type":"ImageObject","inLanguage":"ja","@id":"https:\/\/secure.gravatar.com\/avatar\/8803277856c8b753feb4217dff0f9953327452df1a615c3c88b2f9864efb2ddd?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/8803277856c8b753feb4217dff0f9953327452df1a615c3c88b2f9864efb2ddd?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/8803277856c8b753feb4217dff0f9953327452df1a615c3c88b2f9864efb2ddd?s=96&d=mm&r=g","caption":"LATB Staff"},"url":"https:\/\/admin.acceleratingscience.com\/author\/latbstaff\/"}]}},"taxonomy_info":{"category":[{"value":156,"label":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023"}],"post_tag":[{"value":83,"label":"\u304c\u3093"},{"value":32,"label":"\u6297\u4f53"}]},"featured_image_src_large":["https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/17107e39d57b8bc5e797aba6ae6904eb-1.jpg",760,399,false],"author_info":{"display_name":"LATB Staff","author_link":"https:\/\/admin.acceleratingscience.com\/author\/latbstaff\/"},"comment_info":0,"category_info":[{"term_id":156,"name":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","slug":"mol-bio","term_group":0,"term_taxonomy_id":156,"taxonomy":"category","description":"","parent":0,"count":538,"filter":"raw","meta":[],"cat_ID":156,"category_count":538,"category_description":"","cat_name":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","category_nicename":"mol-bio","category_parent":0}],"tag_info":[{"term_id":83,"name":"\u304c\u3093","slug":"cancer","term_group":0,"term_taxonomy_id":83,"taxonomy":"post_tag","description":"","parent":0,"count":23,"filter":"raw","meta":[]},{"term_id":32,"name":"\u6297\u4f53","slug":"antibody","term_group":0,"term_taxonomy_id":32,"taxonomy":"post_tag","description":"","parent":0,"count":31,"filter":"raw","meta":[]}],"jetpack-related-posts":[{"id":23457,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/cell-culture-cell-culture-basic-bid-ts-mbr-25063\/","url_meta":{"origin":952,"position":0},"title":"\u7d30\u80de\u57f9\u990a\u7528\u306e\u8840\u6e05\uff08FBS\uff09\u3068\u6297\u751f\u7269\u8cea\u306e\u30dd\u30a4\u30f3\u30c8\uff5e\u7d30\u80de\u57f9\u990a\u306e\u5b8c\u5168\u30b5\u30dd\u30fc\u30c8\u30ac\u30a4\u30c9 \u305d\u306e5","author":"LatB Staff","date":"2025\u5e7410\u670822\u65e5","format":false,"excerpt":"\u300c\u7d30\u80de\u57f9\u990a\u306e\u5b8c\u5168\u30b5\u30dd\u30fc\u30c8\u30ac\u30a4\u30c9\u300d\u306f\u3001\u7d30\u80de\u57f9\u990a\u306b\u521d\u3081\u3066\u6311\u6226\u3059\u308b\u65b9\u3084\u3001\u307e\u3060\u7d4c\u9a13\u306e\u6d45\u3044\u65b9\u306b\u5411\u3051\u3066\u3001\u57fa\u790e\u77e5\u8b58\u2026","rel":"","context":"\u7d30\u80de\u57f9\u990a\u30fb\u30a4\u30e1\u30fc\u30b8\u30f3\u30b0","block_context":{"text":"\u7d30\u80de\u57f9\u990a\u30fb\u30a4\u30e1\u30fc\u30b8\u30f3\u30b0","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/cell\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/10\/cell-culture-cell-culture-basic-bid-ts-mbr-25063_eyecatch-scaled.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/10\/cell-culture-cell-culture-basic-bid-ts-mbr-25063_eyecatch-scaled.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/10\/cell-culture-cell-culture-basic-bid-ts-mbr-25063_eyecatch-scaled.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/10\/cell-culture-cell-culture-basic-bid-ts-mbr-25063_eyecatch-scaled.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/10\/cell-culture-cell-culture-basic-bid-ts-mbr-25063_eyecatch-scaled.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/10\/cell-culture-cell-culture-basic-bid-ts-mbr-25063_eyecatch-scaled.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":23098,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/cell-culture-cell-culture-basic-bid-ts-mbr-25059\/","url_meta":{"origin":952,"position":1},"title":"\u7d30\u80de\u57f9\u990a\u7528\u306e\u57f9\u5730\uff5e\u521d\u5fc3\u8005\u5fc5\u898b\uff01\u7d30\u80de\u57f9\u990a\u306e\u5b8c\u5168\u30b5\u30dd\u30fc\u30c8\u30ac\u30a4\u30c9 \u305d\u306e4","author":"LatB Staff","date":"2025\u5e7410\u67082\u65e5","format":false,"excerpt":"\u300c\u7d30\u80de\u57f9\u990a\u306e\u5b8c\u5168\u30b5\u30dd\u30fc\u30c8\u30ac\u30a4\u30c9\u300d\u306f\u3001\u7d30\u80de\u57f9\u990a\u306b\u521d\u3081\u3066\u6311\u6226\u3055\u308c\u308b\u65b9\u3084\u3001\u307e\u3060\u7d4c\u9a13\u306e\u6d45\u3044\u65b9\u306b\u5411\u3051\u3066\u3001\u57fa\u790e\u77e5\u2026","rel":"","context":"\u7d30\u80de\u57f9\u990a\u30fb\u30a4\u30e1\u30fc\u30b8\u30f3\u30b0","block_context":{"text":"\u7d30\u80de\u57f9\u990a\u30fb\u30a4\u30e1\u30fc\u30b8\u30f3\u30b0","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/cell\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/09\/cell-culture-cell-culture-basic-bid-ts-mbr-25059_eycatch.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/09\/cell-culture-cell-culture-basic-bid-ts-mbr-25059_eycatch.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/09\/cell-culture-cell-culture-basic-bid-ts-mbr-25059_eycatch.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/09\/cell-culture-cell-culture-basic-bid-ts-mbr-25059_eycatch.jpg?resize=700%2C400&ssl=1 2x"},"classes":[]},{"id":24152,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/cell-culture-protein-expression-bid-ts-mbr-25074\/","url_meta":{"origin":952,"position":2},"title":"\u30bf\u30f3\u30d1\u30af\u7523\u751f\u3084\u30a6\u30a4\u30eb\u30b9\u7523\u751f\u3092\u76ee\u7684\u3068\u3057\u305f\u9ad8\u5bc6\u5ea6\u7d30\u80de\u57f9\u990a\u30b7\u30b9\u30c6\u30e0\u5c0e\u5165\u306e\u7b2c\u4e00\u6b69\uff1a\u7d30\u80de\u682a\u306e\u7d99\u4ee3\u3068\u51cd\u7d50\u4fdd\u5b58\u7de8","author":"LatB Staff","date":"2025\u5e7412\u67083\u65e5","format":false,"excerpt":"\u9ad8\u5bc6\u5ea6\u7d30\u80de\u57f9\u990a\u30b7\u30b9\u30c6\u30e0\u3067\u306f\u3001\u5c02\u7528\u306e\u6d6e\u904a\u7d30\u80de\u682a\u3092\u7528\u3044\u3066\u6c7a\u3081\u3089\u308c\u305f\u624b\u9806\u3067\u57f9\u990a\u3057\u307e\u3059\u3002\u5b89\u5b9a\u7684\u306b\u904b\u7528\u3059\u308b\u305f\u3081\u2026","rel":"","context":"\u7d30\u80de\u57f9\u990a\u30fb\u30a4\u30e1\u30fc\u30b8\u30f3\u30b0","block_context":{"text":"\u7d30\u80de\u57f9\u990a\u30fb\u30a4\u30e1\u30fc\u30b8\u30f3\u30b0","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/cell\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/11\/cell-culture-protein-expression-bid-ts-mbr-25074_eycatch.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/11\/cell-culture-protein-expression-bid-ts-mbr-25074_eycatch.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/11\/cell-culture-protein-expression-bid-ts-mbr-25074_eycatch.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/11\/cell-culture-protein-expression-bid-ts-mbr-25074_eycatch.jpg?resize=700%2C400&ssl=1 2x"},"classes":[]},{"id":20124,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/exosome-gene-therapy-ts-r-25015\/","url_meta":{"origin":952,"position":3},"title":"\u3010\u7b2c1\u56de\u3011Exosome\uff08\u30a8\u30af\u30bd\u30bd\u30fc\u30e0\uff0f\u30a8\u30ad\u30bd\u30bd\u30fc\u30e0\uff09\u3068\u306f\uff1f","author":"LatB Staff","date":"2026\u5e744\u670815\u65e5","format":false,"excerpt":"Exosome\uff08\u30a8\u30af\u30bd\u30bd\u30fc\u30e0\uff0f\u30a8\u30ad\u30bd\u30bd\u30fc\u30e0\uff09\u306e\u7814\u7a76\u304c\u6ce8\u76ee\u3092\u96c6\u3081\u3066\u3044\u307e\u3059\u3002\u8208\u5473\u306f\u3042\u3063\u3066\u3082\u3001\u3069\u306e\u3088\u3046\u306b\u7814\u2026","rel":"","context":"\u305d\u306e\u4ed6","block_context":{"text":"\u305d\u306e\u4ed6","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/else\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/03\/6fae859c8c1eacdaa39f3ae843ae1bda-scaled.png?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/03\/6fae859c8c1eacdaa39f3ae843ae1bda-scaled.png?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/03\/6fae859c8c1eacdaa39f3ae843ae1bda-scaled.png?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/03\/6fae859c8c1eacdaa39f3ae843ae1bda-scaled.png?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/03\/6fae859c8c1eacdaa39f3ae843ae1bda-scaled.png?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/03\/6fae859c8c1eacdaa39f3ae843ae1bda-scaled.png?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":23765,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/cell-culture-cell-count-bid-ts-mbr-25065\/","url_meta":{"origin":952,"position":4},"title":"\u3010\u3084\u3063\u3066\u307f\u305f\u3011\u51dd\u96c6\u3057\u3084\u3059\u3044\u7d30\u80de\u3092\u3042\u306e\u624b\u3053\u306e\u624b\u3067\u307b\u3050\u3057\u3066\u307f\u305f","author":"LatB Staff","date":"2025\u5e7411\u67084\u65e5","format":false,"excerpt":"\u7d30\u80de\u57f9\u990a\u5b9f\u9a13\u306b\u304a\u3044\u3066\u3001\u7d30\u80de\u6570\u3084\u751f\u7d30\u80de\u7387\u30fb\u6b7b\u7d30\u80de\u7387\u306e\u6e2c\u5b9a\uff08\u3044\u308f\u3086\u308b\u30bb\u30eb\u30ab\u30a6\u30f3\u30c8\uff09\u306f\u91cd\u8981\u306a\u30b9\u30c6\u30c3\u30d7\u3067\u3059\u3002\u2026","rel":"","context":"\u7d30\u80de\u57f9\u990a\u30fb\u30a4\u30e1\u30fc\u30b8\u30f3\u30b0","block_context":{"text":"\u7d30\u80de\u57f9\u990a\u30fb\u30a4\u30e1\u30fc\u30b8\u30f3\u30b0","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/cell\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/10\/cell-culture-cell-count-bid-ts-mbr-25065_eyecatch-scaled.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/10\/cell-culture-cell-count-bid-ts-mbr-25065_eyecatch-scaled.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/10\/cell-culture-cell-count-bid-ts-mbr-25065_eyecatch-scaled.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/10\/cell-culture-cell-count-bid-ts-mbr-25065_eyecatch-scaled.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/10\/cell-culture-cell-count-bid-ts-mbr-25065_eyecatch-scaled.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/10\/cell-culture-cell-count-bid-ts-mbr-25065_eyecatch-scaled.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":25608,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/cell-culture-basic-cell-culture-bpg-26026\/","url_meta":{"origin":952,"position":5},"title":"\u3010\u7b2c3\u56de\u3011Gibco\u57f9\u5730 60\u5e74\u306e\u30a4\u30ce\u30d9\u30fc\u30b7\u30e7\u30f3\u3002\u7d30\u80de\u57f9\u990a\u306e\u6b74\u53f2\u306f\u57f9\u5730\u306e\u6b74\u53f2\u3002","author":"LatB Staff","date":"2026\u5e7410\u67087\u65e5","format":false,"excerpt":"\u3053\u306e\u30d6\u30ed\u30b0\u3067\u306f\u3001\u30d0\u30a4\u30aa\u30d7\u30ed\u30c0\u30af\u30b7\u30e7\u30f3\u30c1\u30fc\u30e0\u304c\u533b\u85ac\u54c1\u88fd\u9020\u306b\u95a2\u9023\u3059\u308b\u3055\u307e\u3056\u307e\u306a\u30c8\u30d4\u30c3\u30af\u3092\u30b7\u30ea\u30fc\u30ba\u3067\u3054\u7d39\u4ecb\u2026","rel":"","context":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","block_context":{"text":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/mol-bio\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/08\/cell-culture-basic-cell-culture-bpg-26026_eyecatch.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/08\/cell-culture-basic-cell-culture-bpg-26026_eyecatch.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/08\/cell-culture-basic-cell-culture-bpg-26026_eyecatch.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/08\/cell-culture-basic-cell-culture-bpg-26026_eyecatch.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/08\/cell-culture-basic-cell-culture-bpg-26026_eyecatch.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/08\/cell-culture-basic-cell-culture-bpg-26026_eyecatch.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]}],"jetpack_sharing_enabled":true,"amp_enabled":true,"jetpack_featured_media_url":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/17107e39d57b8bc5e797aba6ae6904eb-1.jpg","_links":{"self":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/posts\/952","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/users\/988"}],"replies":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/comments?post=952"}],"version-history":[{"count":0,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/posts\/952\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/media\/3902"}],"wp:attachment":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/media?parent=952"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/categories?post=952"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/tags?post=952"},{"taxonomy":"division","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/division?post=952"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}