{"id":8377,"date":"2026-08-25T13:36:30","date_gmt":"2026-08-25T13:36:30","guid":{"rendered":"https:\/\/www.thermofisher.com\/blog\/life-in-the-lab\/?p=8377"},"modified":"2026-08-25T13:36:33","modified_gmt":"2026-08-25T13:36:33","slug":"bioprocessing-single-use-process-control-scale-up","status":"publish","type":"post","link":"https:\/\/www.thermofisher.com\/blog\/life-in-the-lab\/bioprocessing-single-use-process-control-scale-up\/","title":{"rendered":"How can biomanufacturers strengthen process control as they scale operations?"},"content":{"rendered":"\n<div class=\"wp-block-tf-blocks-definition-block\">\n<figure class=\"wp-block-image size-large is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"602\" src=\"https:\/\/admin.acceleratingscience.com\/life-in-the-lab\/wp-content\/uploads\/sites\/10\/2026\/08\/Process-Control-Blog-Header-Image-1024x602.jpg\" alt=\"Process Control-Blog-Header-Image\" class=\"wp-image-8390\" style=\"width:1570px\" srcset=\"https:\/\/admin.acceleratingscience.com\/life-in-the-lab\/wp-content\/uploads\/sites\/10\/2026\/08\/Process-Control-Blog-Header-Image-1024x602.jpg 1024w, https:\/\/admin.acceleratingscience.com\/life-in-the-lab\/wp-content\/uploads\/sites\/10\/2026\/08\/Process-Control-Blog-Header-Image-300x176.jpg 300w, https:\/\/admin.acceleratingscience.com\/life-in-the-lab\/wp-content\/uploads\/sites\/10\/2026\/08\/Process-Control-Blog-Header-Image-768x452.jpg 768w, https:\/\/admin.acceleratingscience.com\/life-in-the-lab\/wp-content\/uploads\/sites\/10\/2026\/08\/Process-Control-Blog-Header-Image-1536x904.jpg 1536w, https:\/\/admin.acceleratingscience.com\/life-in-the-lab\/wp-content\/uploads\/sites\/10\/2026\/08\/Process-Control-Blog-Header-Image-2048x1205.jpg 2048w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<p>Biomanufacturers can strengthen process control during scale-up by centralizing process data, connecting equipment through distributed control systems (DCS), and standardizing data models and control strategies across scales. This approach improves process visibility and traceability while reducing manual configuration, variability, and tech transfer complexity.<\/p>\n<\/div>\n\n\n<style>.wp-block-kadence-spacer.kt-block-spacer-8377_7afda8-f7 .kt-block-spacer{height:20px;}.wp-block-kadence-spacer.kt-block-spacer-8377_7afda8-f7 .kt-divider{border-top-width:1px;height:1px;border-top-color:#eee;width:100%;border-top-style:solid;}<\/style>\n<div class=\"wp-block-kadence-spacer aligncenter kt-block-spacer-8377_7afda8-f7\"><div class=\"kt-block-spacer kt-block-spacer-halign-center\"><\/div><\/div>\n\n\n\n<div class=\"wp-block-tf-blocks-definition-block\">\n<h2 class=\"wp-block-heading\" id=\"h-introduction\">Introduction<\/h2>\n\n\n\n<p><\/p>\n\n\n\n<p>As biomanufacturers scale from process development to commercial production, maintaining process visibility and consistency becomes increasingly difficult. Multiproduct facilities, hybrid manufacturing environments, and growing automation demands often introduce disconnected systems, inconsistent data architectures, and operational silos that can slow scale-up and weaken process control.<\/p>\n\n\n\n<p>From bench-scale development to commercial manufacturing, tech transfer can also become increasingly complex and time-consuming due to different vessel sizes and disparate automation platforms. Manufacturers can encounter several challenges, including:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Additional manual labor during tech transfer<\/li>\n\n\n\n<li>Limited continuity of process data across the manufacturing lifecycle<\/li>\n\n\n\n<li>Increased variability during scale-up<\/li>\n<\/ul>\n\n\n\n<p>At the same time, manufacturers are under increasing pressure to maintain compliance by quickly identifying and investigating deviations. When alarms, events, audit trails, and process data exist across multiple systems, gaining a clear operational picture becomes more difficult.<\/p>\n\n\n\n<p>To address these challenges, many manufacturers are adopting centralized automation and scalable analytics strategies that help improve process visibility, simplify tech transfer, and support more connected manufacturing operations.<\/p>\n<\/div>\n\n\n<style>.wp-block-kadence-advancedbtn.kb-btns8377_149078-ea{gap:var(--global-kb-gap-xs, 0.5rem );justify-content:flex-start;align-items:center;}.kt-btns8377_149078-ea .kt-button{font-weight:normal;font-style:normal;}.kt-btns8377_149078-ea .kt-btn-wrap-0{margin-right:5px;}.wp-block-kadence-advancedbtn.kt-btns8377_149078-ea .kt-btn-wrap-0 .kt-button{color:#555555;border-color:#555555;}.wp-block-kadence-advancedbtn.kt-btns8377_149078-ea .kt-btn-wrap-0 .kt-button:hover, .wp-block-kadence-advancedbtn.kt-btns8377_149078-ea .kt-btn-wrap-0 .kt-button:focus{color:#ffffff;border-color:#444444;}.wp-block-kadence-advancedbtn.kt-btns8377_149078-ea .kt-btn-wrap-0 .kt-button::before{display:none;}.wp-block-kadence-advancedbtn.kt-btns8377_149078-ea .kt-btn-wrap-0 .kt-button:hover, .wp-block-kadence-advancedbtn.kt-btns8377_149078-ea .kt-btn-wrap-0 .kt-button:focus{background:#444444;}<\/style>\n<div class=\"wp-block-kadence-advancedbtn kb-buttons-wrap kb-btns8377_149078-ea\"><style>ul.menu .wp-block-kadence-advancedbtn .kb-btn8377_828056-de.kb-button{width:initial;}.wp-block-kadence-advancedbtn .kb-btn8377_828056-de.kb-button{background:#cf2e2e;}.wp-block-kadence-advancedbtn .kb-btn8377_828056-de.kb-button:hover, .wp-block-kadence-advancedbtn .kb-btn8377_828056-de.kb-button:focus{background:#cf2e2e;}<\/style><a class=\"kb-button kt-button button kb-btn8377_828056-de kt-btn-size-large kt-btn-width-type-auto kb-btn-global-fill  kt-btn-has-text-true kt-btn-has-svg-false  wp-block-kadence-singlebtn\" href=\"https:\/\/www.thermofisher.com\/us\/en\/home\/global\/forms\/bioprocessing\/single-use\/insights-hub.html\"><span class=\"kt-btn-inner-text\">Subscribe Now<\/span><\/a><\/div>\n\n\n<style>.wp-block-kadence-spacer.kt-block-spacer-8377_947be6-ff .kt-block-spacer{height:20px;}.wp-block-kadence-spacer.kt-block-spacer-8377_947be6-ff .kt-divider{border-top-width:1px;height:1px;border-top-color:#eee;width:100%;border-top-style:solid;}<\/style>\n<div class=\"wp-block-kadence-spacer aligncenter kt-block-spacer-8377_947be6-ff\"><div class=\"kt-block-spacer kt-block-spacer-halign-center\"><\/div><\/div>\n\n\n\n<div class=\"wp-block-tf-blocks-definition-block\">\n<h2 class=\"wp-block-heading\" id=\"h-why-is-centralized-data-aggregation-important-for-process-control\">Why is centralized data aggregation important for process control?<\/h2>\n\n\n\n<p><\/p>\n\n\n\n<p>Bioprocess data is often spread across multiple equipment platforms, vendors, and software systems. This fragmentation can create data silos and affect compliance readiness, making it harder to identify, trace, and review audit trails.<\/p>\n\n\n\n<p>A centralized data management strategy enables a single source of truth across manufacturing operations, helping to streamline traceability, strengthen data integrity, and provide operators with better visibility into process performance. With centralized access to process data, manufacturers can streamline deviation investigations and make fast operational decisions.<\/p>\n<\/div>\n\n\n<style>.wp-block-kadence-spacer.kt-block-spacer-8377_9c81bb-85 .kt-block-spacer{height:20px;}.wp-block-kadence-spacer.kt-block-spacer-8377_9c81bb-85 .kt-divider{border-top-width:1px;height:1px;border-top-color:#eee;width:100%;border-top-style:solid;}<\/style>\n<div class=\"wp-block-kadence-spacer aligncenter kt-block-spacer-8377_9c81bb-85\"><div class=\"kt-block-spacer kt-block-spacer-halign-center\"><hr class=\"kt-divider\" \/><\/div><\/div>\n\n\n\n<div class=\"wp-block-tf-blocks-definition-block\">\n<h2 class=\"wp-block-heading\" id=\"h-how-can-distributed-control-systems-dcs-help-improve-scale-up-and-simplify-tech-transfer\">How can distributed control systems (DCS) help improve scale-up and simplify tech transfer?<\/h2>\n\n\n\n<p><\/p>\n\n\n\n<p>As biomanufacturing operations scale, many facilities find themselves managing multiple automation platforms across vessel sizes, production lines, and sites. When process development, scale-up, and manufacturing systems operate independently, they can create data silos, increase tech transfer complexity, and reduce visibility across the broader process workflow. Unlike isolated programmable logic controller (PLC)- based systems, DCS allow operators to monitor processes holistically and share data between equipment across upstream and downstream operations.<\/p>\n<\/div>\n\n\n<style>.wp-block-kadence-spacer.kt-block-spacer-8377_6b07c1-af .kt-block-spacer{height:20px;}.wp-block-kadence-spacer.kt-block-spacer-8377_6b07c1-af .kt-divider{border-top-width:1px;height:1px;border-top-color:#eee;width:100%;border-top-style:solid;}<\/style>\n<div class=\"wp-block-kadence-spacer aligncenter kt-block-spacer-8377_6b07c1-af\"><div class=\"kt-block-spacer kt-block-spacer-halign-center\"><hr class=\"kt-divider\" \/><\/div><\/div>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-isolated-automation-vs-distributed-control-systems\">Isolated Automation vs. Distributed Control Systems<\/h2>\n\n\n\n<p><\/p>\n\n\n<style>.kb-table-container8377_f671d2-c4{overflow-x:auto;}.kb-table8377_f671d2-c4 tr > *:nth-child(1){width:30%;}.kb-table8377_f671d2-c4 tr > *:nth-child(2){width:35%;}.kb-table8377_f671d2-c4 tr > *:nth-child(3){width:35%;}.kb-table8377_f671d2-c4{table-layout:fixed;width:100%;}.kb-table-container .kb-table8377_f671d2-c4 th{padding-top:var(--global-kb-spacing-xxs, 0.5rem);padding-right:var(--global-kb-spacing-xxs, 0.5rem);padding-bottom:var(--global-kb-spacing-xxs, 0.5rem);padding-left:var(--global-kb-spacing-xxs, 0.5rem);text-align:center;}.kb-table-container .kb-table8377_f671d2-c4 caption{text-align:center;}.kb-table-container .kb-table8377_f671d2-c4 td{padding-top:var(--global-kb-spacing-xxs, 0.5rem);padding-right:var(--global-kb-spacing-xxs, 0.5rem);padding-bottom:var(--global-kb-spacing-xxs, 0.5rem);padding-left:var(--global-kb-spacing-xxs, 0.5rem);text-align:left;}.kb-table-container .kb-table8377_f671d2-c4 td, .kb-table8377_f671d2-c4 th{border-top:1px solid #abb8c3;border-right:1px solid #abb8c3;border-bottom:1px solid #abb8c3;border-left:1px solid #abb8c3;}@media all and (max-width: 1024px){.kb-table-container .kb-table8377_f671d2-c4 td, .kb-table8377_f671d2-c4 th{border-top:1px solid #abb8c3;border-right:1px solid #abb8c3;border-bottom:1px solid #abb8c3;border-left:1px solid #abb8c3;}}@media all and (max-width: 767px){.kb-table-container .kb-table8377_f671d2-c4 td, .kb-table8377_f671d2-c4 th{border-top:1px solid #abb8c3;border-right:1px solid #abb8c3;border-bottom:1px solid #abb8c3;border-left:1px solid #abb8c3;}}<\/style><div class=\"kb-table-container kb-table-container8377_f671d2-c4 wp-block-kadence-table\"><table class=\"kb-table kb-table8377_f671d2-c4\">\n<style>.kb-table-container .kb-table tr.kb-table-row8377_c9fffe-9e{background-color:rgba(151,154,156,0.17);}<\/style><tr class=\"kb-table-row kb-table-row8377_c9fffe-9e\">\n<td  class=\"kb-table-data kb-table-data8377_9433ad-e1\">\n\n<p><strong>Consideration<\/strong><\/p>\n\n<\/td>\n\n<td  class=\"kb-table-data kb-table-data8377_30a2f6-e2\">\n\n<p><strong>Isolated Automation \/ <\/strong><br><strong>PLC-Based Systems<\/strong><\/p>\n\n<\/td>\n\n<td  class=\"kb-table-data kb-table-data8377_6af4b3-c0\">\n\n<p id=\"h-distributed-control-system-dcs\"><strong>Distributed Control System (DCS)<\/strong><\/p>\n\n<\/td>\n<\/tr>\n\n<tr class=\"kb-table-row kb-table-row8377_aa61be-27\">\n<td  class=\"kb-table-data kb-table-data8377_585920-93\">\n\n<p>Process visibility<\/p>\n\n<\/td>\n\n<td  class=\"kb-table-data kb-table-data8377_41f3d4-aa\">\n\n<p>Individual systems or equipment<\/p>\n\n<\/td>\n\n<td  class=\"kb-table-data kb-table-data8377_b8ae13-7a\">\n\n<p>Broader process visibility<\/p>\n\n<\/td>\n<\/tr>\n\n<tr class=\"kb-table-row kb-table-row8377_92424a-d4\">\n<td  class=\"kb-table-data kb-table-data8377_dba92a-65\">\n\n<p>Data sharing<\/p>\n\n<\/td>\n\n<td  class=\"kb-table-data kb-table-data8377_4a6baf-d1\">\n\n<p>Can remain siloed<\/p>\n\n<\/td>\n\n<td  class=\"kb-table-data kb-table-data8377_c57bfc-14\">\n\n<p>Supports data sharing across equipment<\/p>\n\n<\/td>\n<\/tr>\n\n<tr class=\"kb-table-row kb-table-row8377_33f644-7d\">\n<td  class=\"kb-table-data kb-table-data8377_d9c7c9-97\">\n\n<p>Scale-up configuration<\/p>\n\n<\/td>\n\n<td  class=\"kb-table-data kb-table-data8377_56ef29-fc\">\n\n<p>Settings may require manual recreation<\/p>\n\n<\/td>\n\n<td  class=\"kb-table-data kb-table-data8377_50a729-0c\">\n\n<p>Reusable control strategies can support scale-up<\/p>\n\n<\/td>\n<\/tr>\n\n<tr class=\"kb-table-row kb-table-row8377_bc5314-96\">\n<td  class=\"kb-table-data kb-table-data8377_90eace-07\">\n\n<p>Data consistency<\/p>\n\n<\/td>\n\n<td  class=\"kb-table-data kb-table-data8377_1e81f3-dd\">\n\n<p>Naming and structures may vary<\/p>\n\n<\/td>\n\n<td  class=\"kb-table-data kb-table-data8377_a07abb-81\">\n\n<p>Standardized architectures can improve consistency<\/p>\n\n<\/td>\n<\/tr>\n\n<tr class=\"kb-table-row kb-table-row8377_638eef-7b\">\n<td  class=\"kb-table-data kb-table-data8377_1d0137-7b\">\n\n<p>Tech transfer<\/p>\n\n<\/td>\n\n<td  class=\"kb-table-data kb-table-data8377_ddb5c6-7a\">\n\n<p>Greater manual configuration complexity<\/p>\n\n<\/td>\n\n<td  class=\"kb-table-data kb-table-data8377_dc67bf-fb\">\n\n<p>Supports transfer of verified process configurations<\/p>\n\n<\/td>\n<\/tr>\n<\/table><\/div>\n\n\n<div class=\"wp-block-tf-blocks-definition-block\">\n<p>Additionally, inconsistent naming conventions and data structures across platforms can make it difficult to unify process data across equipment, facilities, and production stages. For example, the same process parameter may be labeled differently between systems, vessels, or automation platforms, creating disconnected data that complicates downstream integration.<\/p>\n\n\n\n<p id=\"h-\">Rebuilding process settings manually across scales or facilities can also increase the risk of human error and make process knowledge transfer more difficult to maintain. By using standardized DCS architectures and reusable control strategies, biomanufacturers can reduce variability by enabling operators to apply verified process configurations across production lines and vessel sizes rather than recreating settings manually for each run.<\/p>\n<\/div>\n\n\n<style>.wp-block-kadence-spacer.kt-block-spacer-8377_71aa61-f0 .kt-block-spacer{height:20px;}.wp-block-kadence-spacer.kt-block-spacer-8377_71aa61-f0 .kt-divider{border-top-width:1px;height:1px;border-top-color:#eee;width:100%;border-top-style:solid;}<\/style>\n<div class=\"wp-block-kadence-spacer aligncenter kt-block-spacer-8377_71aa61-f0\"><div class=\"kt-block-spacer kt-block-spacer-halign-center\"><hr class=\"kt-divider\" \/><\/div><\/div>\n\n\n\n<div class=\"wp-block-tf-blocks-definition-block\">\n<h2 class=\"wp-block-heading\" id=\"h-building-a-more-connected-manufacturing-strategy\">Building a more connected manufacturing strategy<\/h2>\n\n\n\n<p><\/p>\n\n\n\n<p>As biomanufacturing operations become more complex, strengthening process control requires more than standalone data systems or <strong>isolated automation tools.<\/strong><\/p>\n\n\n\n<p>Biomanufacturers can help strengthen process control by:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Centralizing process data to improve traceability and streamline deviation investigations<\/li>\n\n\n\n<li>Using DCS to connect equipment and improve operational visibility<\/li>\n\n\n\n<li>Standardizing data models and control strategies across vessel sizes and facilities<\/li>\n\n\n\n<li>Reducing manual configuration steps during scale-up and tech transfer to help minimize variability<\/li>\n<\/ul>\n<\/div>\n\n\n<style>.wp-block-kadence-advancedbtn.kb-btns8377_ae9a63-dc{gap:var(--global-kb-gap-xs, 0.5rem );justify-content:flex-start;align-items:center;}.kt-btns8377_ae9a63-dc .kt-button{font-weight:normal;font-style:normal;}.kt-btns8377_ae9a63-dc .kt-btn-wrap-0{margin-right:5px;}.wp-block-kadence-advancedbtn.kt-btns8377_ae9a63-dc .kt-btn-wrap-0 .kt-button{color:#555555;border-color:#555555;}.wp-block-kadence-advancedbtn.kt-btns8377_ae9a63-dc .kt-btn-wrap-0 .kt-button:hover, .wp-block-kadence-advancedbtn.kt-btns8377_ae9a63-dc .kt-btn-wrap-0 .kt-button:focus{color:#ffffff;border-color:#444444;}.wp-block-kadence-advancedbtn.kt-btns8377_ae9a63-dc .kt-btn-wrap-0 .kt-button::before{display:none;}.wp-block-kadence-advancedbtn.kt-btns8377_ae9a63-dc .kt-btn-wrap-0 .kt-button:hover, .wp-block-kadence-advancedbtn.kt-btns8377_ae9a63-dc .kt-btn-wrap-0 .kt-button:focus{background:#444444;}<\/style>\n<div class=\"wp-block-kadence-advancedbtn kb-buttons-wrap kb-btns8377_ae9a63-dc\"><style>ul.menu .wp-block-kadence-advancedbtn .kb-btn8377_635d64-cb.kb-button{width:initial;}.wp-block-kadence-advancedbtn .kb-btn8377_635d64-cb.kb-button{background:#979a9c;}.wp-block-kadence-advancedbtn .kb-btn8377_635d64-cb.kb-button:hover, .wp-block-kadence-advancedbtn .kb-btn8377_635d64-cb.kb-button:focus{color:#abb8c3;background:#ffffff;border-top:1px solid #abb8c3;border-right:1px solid #abb8c3;border-bottom:1px solid #abb8c3;border-left:1px solid #abb8c3;}@media all and (max-width: 1024px){.wp-block-kadence-advancedbtn .kb-btn8377_635d64-cb.kb-button:hover, .wp-block-kadence-advancedbtn .kb-btn8377_635d64-cb.kb-button:focus{border-top:1px solid #abb8c3;border-right:1px solid #abb8c3;border-bottom:1px solid #abb8c3;border-left:1px solid #abb8c3;}}@media all and (max-width: 767px){.wp-block-kadence-advancedbtn .kb-btn8377_635d64-cb.kb-button:hover, .wp-block-kadence-advancedbtn .kb-btn8377_635d64-cb.kb-button:focus{border-top:1px solid #abb8c3;border-right:1px solid #abb8c3;border-bottom:1px solid #abb8c3;border-left:1px solid #abb8c3;}}<\/style><a class=\"kb-button kt-button button kb-btn8377_635d64-cb kt-btn-size-large kt-btn-width-type-auto kb-btn-global-fill  kt-btn-has-text-true kt-btn-has-svg-false  wp-block-kadence-singlebtn\" href=\"https:\/\/documents.thermofisher.com\/TFS-Assets\/BPD\/Flyers\/biomanufacturers-strengthen-centralized-dcs-automation-flyer.pdf\" target=\"_blank\" rel=\"noreferrer noopener\"><span class=\"kt-btn-inner-text\">Download PDF<\/span><\/a><\/div>\n\n\n<style>.wp-block-kadence-spacer.kt-block-spacer-8377_9ea7e0-36 .kt-block-spacer{height:20px;}.wp-block-kadence-spacer.kt-block-spacer-8377_9ea7e0-36 .kt-divider{border-top-width:1px;height:1px;border-top-color:#eee;width:100%;border-top-style:solid;}<\/style>\n<div class=\"wp-block-kadence-spacer aligncenter kt-block-spacer-8377_9ea7e0-36\"><div class=\"kt-block-spacer kt-block-spacer-halign-center\"><\/div><\/div>\n\n\n\n<figure class=\"wp-block-image alignright size-full is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"405\" height=\"279\" src=\"http:\/\/admin.acceleratingscience.com\/life-in-the-lab\/wp-content\/uploads\/sites\/10\/2026\/08\/Screenshot-2026-08-20-121407.png\" alt=\"product spotlight\" class=\"wp-image-8531\" style=\"width:350px\" srcset=\"https:\/\/admin.acceleratingscience.com\/life-in-the-lab\/wp-content\/uploads\/sites\/10\/2026\/08\/Screenshot-2026-08-20-121407.png 405w, https:\/\/admin.acceleratingscience.com\/life-in-the-lab\/wp-content\/uploads\/sites\/10\/2026\/08\/Screenshot-2026-08-20-121407-300x207.png 300w, https:\/\/admin.acceleratingscience.com\/life-in-the-lab\/wp-content\/uploads\/sites\/10\/2026\/08\/Screenshot-2026-08-20-121407-96x65.png 96w\" sizes=\"auto, (max-width: 405px) 100vw, 405px\" \/><\/figure>\n\n\n\n<div class=\"wp-block-tf-blocks-definition-block\">\n<h3 class=\"wp-block-heading\" id=\"h-product-spotlight\">Product spotlight<\/h3>\n\n\n\n<p><\/p>\n\n\n\n<p>See how Thermo Scientific <a href=\"https:\/\/www.thermofisher.com\/us\/en\/home\/bioprocessing\/products\/single-use\/automation-data-management\/software.html?\">TruBio Process Control Software on the DeltaV<\/a> Live platform helps reduce variability and strengthen process control through integrated automation and real-time analytics.<\/p>\n<\/div>\n\n\n\n<p><\/p>\n\n\n\n<p><\/p>\n\n\n\n<p><\/p>\n\n\n<style>.wp-block-kadence-spacer.kt-block-spacer-8377_7b3f06-4f .kt-block-spacer{height:6px;}.wp-block-kadence-spacer.kt-block-spacer-8377_7b3f06-4f .kt-divider{border-top-width:1px;height:1px;border-top-color:#eee;width:80%;border-top-style:solid;}<\/style>\n<div class=\"wp-block-kadence-spacer aligncenter kt-block-spacer-8377_7b3f06-4f\"><div class=\"kt-block-spacer kt-block-spacer-halign-center\"><\/div><\/div>\n\n\n\n<p class=\"has-medium-font-size\">Explore more strategies in the <a href=\"https:\/\/www.thermofisher.com\/us\/en\/home\/bioprocessing\/resources\/insights-hub.html?\">Bioprocess Insights Hub<\/a>.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Isolated Automation vs. Distributed Control Systems Explore more strategies in the Bioprocess Insights Hub.<\/p>\n","protected":false},"author":1867,"featured_media":8390,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_monsterinsights_skip_tracking":false,"_genesis_hide_title":false,"_genesis_hide_breadcrumbs":false,"_genesis_hide_singular_image":false,"_genesis_hide_footer_widgets":false,"_genesis_custom_body_class":"","_genesis_custom_post_class":"","_genesis_layout":"","_jetpack_newsletter_access":"","_jetpack_dont_email_post_to_subs":false,"_jetpack_newsletter_tier_id":0,"_jetpack_memberships_contains_paywalled_content":false,"_jetpack_memberships_contains_paid_content":false,"footnotes":""},"categories":[24],"tags":[1599,1602,1504,1601,1592,1600,1603,1234],"division":[],"class_list":{"0":"post-8377","1":"post","2":"type-post","3":"status-publish","4":"format-standard","5":"has-post-thumbnail","7":"category-bioprocessing","8":"tag-biomanufacturing-process-control-2","9":"tag-biomanufacturing-scale-up-2","10":"tag-bioprocess-automation","11":"tag-centralized-process-data-2","12":"tag-distributed-control-system-dcs","13":"tag-process-control-2","14":"tag-process-data-management-2","15":"tag-tech-transfer","16":"entry"},"_selected_authors":[1475],"_selected_reviewers":[],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v27.8 (Yoast SEO v27.8) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>How can biomanufacturers strengthen process control as they scale operations? - Life in the Lab<\/title>\n<meta name=\"description\" content=\"Learn how centralized process data and distributed control systems help biomanufacturers improve process control, scale-up, and tech transfer.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.thermofisher.com\/blog\/life-in-the-lab\/bioprocessing-single-use-process-control-scale-up\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"How can biomanufacturers strengthen process control as they scale operations?\" \/>\n<meta property=\"og:description\" content=\"Learn how centralized process data and distributed control systems help biomanufacturers improve process control, scale-up, and tech transfer.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.thermofisher.com\/blog\/life-in-the-lab\/bioprocessing-single-use-process-control-scale-up\/\" \/>\n<meta property=\"og:site_name\" content=\"Life in the Lab\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/thermofisher\" \/>\n<meta property=\"article:published_time\" content=\"2026-08-25T13:36:30+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2026-08-25T13:36:33+00:00\" \/>\n<meta property=\"og:image\" content=\"http:\/\/admin.acceleratingscience.com\/life-in-the-lab\/wp-content\/uploads\/sites\/10\/2026\/08\/Process-Control-Blog-Header-Image-scaled.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"2560\" \/>\n\t<meta property=\"og:image:height\" content=\"1506\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"Chandra Trisuel Kamatham\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:creator\" content=\"@thermofisher\" \/>\n<meta name=\"twitter:site\" content=\"@thermofisher\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Chandra Trisuel Kamatham\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"4 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/life-in-the-lab\\\/bioprocessing-single-use-process-control-scale-up\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/life-in-the-lab\\\/bioprocessing-single-use-process-control-scale-up\\\/\"},\"author\":{\"name\":\"Chandra Trisuel Kamatham\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/life-in-the-lab\\\/#\\\/schema\\\/person\\\/4fcc1f6ee629bcf55630e406799baa05\"},\"headline\":\"How can biomanufacturers strengthen process control as they scale operations?\",\"datePublished\":\"2026-08-25T13:36:30+00:00\",\"dateModified\":\"2026-08-25T13:36:33+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/life-in-the-lab\\\/bioprocessing-single-use-process-control-scale-up\\\/\"},\"wordCount\":673,\"commentCount\":0,\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/life-in-the-lab\\\/bioprocessing-single-use-process-control-scale-up\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/life-in-the-lab\\\/wp-content\\\/uploads\\\/sites\\\/10\\\/2026\\\/08\\\/Process-Control-Blog-Header-Image-scaled.jpg\",\"keywords\":[\"Biomanufacturing process control\",\"Biomanufacturing scale-up\",\"bioprocess automation\",\"Centralized process data\",\"Distributed control system (DCS) \u2022\",\"Process control\",\"Process data management\",\"tech transfer\"],\"articleSection\":[\"Bioprocessing\"],\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/life-in-the-lab\\\/bioprocessing-single-use-process-control-scale-up\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/life-in-the-lab\\\/bioprocessing-single-use-process-control-scale-up\\\/\",\"url\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/life-in-the-lab\\\/bioprocessing-single-use-process-control-scale-up\\\/\",\"name\":\"How can biomanufacturers strengthen process control as they scale operations? - Life in the Lab\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/life-in-the-lab\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/life-in-the-lab\\\/bioprocessing-single-use-process-control-scale-up\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/life-in-the-lab\\\/bioprocessing-single-use-process-control-scale-up\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/life-in-the-lab\\\/wp-content\\\/uploads\\\/sites\\\/10\\\/2026\\\/08\\\/Process-Control-Blog-Header-Image-scaled.jpg\",\"datePublished\":\"2026-08-25T13:36:30+00:00\",\"dateModified\":\"2026-08-25T13:36:33+00:00\",\"author\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/life-in-the-lab\\\/#\\\/schema\\\/person\\\/4fcc1f6ee629bcf55630e406799baa05\"},\"description\":\"Learn how centralized process data and distributed control systems help biomanufacturers improve process control, scale-up, and tech transfer.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/life-in-the-lab\\\/bioprocessing-single-use-process-control-scale-up\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/life-in-the-lab\\\/bioprocessing-single-use-process-control-scale-up\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/life-in-the-lab\\\/bioprocessing-single-use-process-control-scale-up\\\/#primaryimage\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/life-in-the-lab\\\/wp-content\\\/uploads\\\/sites\\\/10\\\/2026\\\/08\\\/Process-Control-Blog-Header-Image-scaled.jpg\",\"contentUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/life-in-the-lab\\\/wp-content\\\/uploads\\\/sites\\\/10\\\/2026\\\/08\\\/Process-Control-Blog-Header-Image-scaled.jpg\",\"width\":2560,\"height\":1506,\"caption\":\"Process-Control-Blog-Header-Image-scaled\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/life-in-the-lab\\\/bioprocessing-single-use-process-control-scale-up\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/life-in-the-lab\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"How can biomanufacturers strengthen process control as they scale operations?\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/life-in-the-lab\\\/#website\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/life-in-the-lab\\\/\",\"name\":\"Life in the Lab\",\"description\":\"\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/life-in-the-lab\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/life-in-the-lab\\\/#\\\/schema\\\/person\\\/4fcc1f6ee629bcf55630e406799baa05\",\"name\":\"Chandra Trisuel Kamatham\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/bf386d486485be363eaf4625350d93db852a089f51ebf9c93d497cb3d7f73963?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/bf386d486485be363eaf4625350d93db852a089f51ebf9c93d497cb3d7f73963?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/bf386d486485be363eaf4625350d93db852a089f51ebf9c93d497cb3d7f73963?s=96&d=mm&r=g\",\"caption\":\"Chandra Trisuel Kamatham\"},\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/author\\\/chandratrisuel-kamatham1thermofisher-com\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"How can biomanufacturers strengthen process control as they scale operations? - Life in the Lab","description":"Learn how centralized process data and distributed control systems help biomanufacturers improve process control, scale-up, and tech transfer.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.thermofisher.com\/blog\/life-in-the-lab\/bioprocessing-single-use-process-control-scale-up\/","og_locale":"en_US","og_type":"article","og_title":"How can biomanufacturers strengthen process control as they scale operations?","og_description":"Learn how centralized process data and distributed control systems help biomanufacturers improve process control, scale-up, and tech transfer.","og_url":"https:\/\/www.thermofisher.com\/blog\/life-in-the-lab\/bioprocessing-single-use-process-control-scale-up\/","og_site_name":"Life in the Lab","article_publisher":"https:\/\/www.facebook.com\/thermofisher","article_published_time":"2026-08-25T13:36:30+00:00","article_modified_time":"2026-08-25T13:36:33+00:00","og_image":[{"width":2560,"height":1506,"url":"http:\/\/admin.acceleratingscience.com\/life-in-the-lab\/wp-content\/uploads\/sites\/10\/2026\/08\/Process-Control-Blog-Header-Image-scaled.jpg","type":"image\/jpeg"}],"author":"Chandra Trisuel Kamatham","twitter_card":"summary_large_image","twitter_creator":"@thermofisher","twitter_site":"@thermofisher","twitter_misc":{"Written by":"Chandra Trisuel Kamatham","Est. reading time":"4 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.thermofisher.com\/blog\/life-in-the-lab\/bioprocessing-single-use-process-control-scale-up\/#article","isPartOf":{"@id":"https:\/\/www.thermofisher.com\/blog\/life-in-the-lab\/bioprocessing-single-use-process-control-scale-up\/"},"author":{"name":"Chandra Trisuel Kamatham","@id":"https:\/\/admin.acceleratingscience.com\/life-in-the-lab\/#\/schema\/person\/4fcc1f6ee629bcf55630e406799baa05"},"headline":"How can biomanufacturers strengthen process control as they scale operations?","datePublished":"2026-08-25T13:36:30+00:00","dateModified":"2026-08-25T13:36:33+00:00","mainEntityOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/life-in-the-lab\/bioprocessing-single-use-process-control-scale-up\/"},"wordCount":673,"commentCount":0,"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/life-in-the-lab\/bioprocessing-single-use-process-control-scale-up\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/life-in-the-lab\/wp-content\/uploads\/sites\/10\/2026\/08\/Process-Control-Blog-Header-Image-scaled.jpg","keywords":["Biomanufacturing process control","Biomanufacturing scale-up","bioprocess automation","Centralized process data","Distributed control system (DCS) \u2022","Process control","Process data management","tech transfer"],"articleSection":["Bioprocessing"],"inLanguage":"en-US","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/www.thermofisher.com\/blog\/life-in-the-lab\/bioprocessing-single-use-process-control-scale-up\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/www.thermofisher.com\/blog\/life-in-the-lab\/bioprocessing-single-use-process-control-scale-up\/","url":"https:\/\/www.thermofisher.com\/blog\/life-in-the-lab\/bioprocessing-single-use-process-control-scale-up\/","name":"How can biomanufacturers strengthen process control as they scale operations? - Life in the Lab","isPartOf":{"@id":"https:\/\/admin.acceleratingscience.com\/life-in-the-lab\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/life-in-the-lab\/bioprocessing-single-use-process-control-scale-up\/#primaryimage"},"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/life-in-the-lab\/bioprocessing-single-use-process-control-scale-up\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/life-in-the-lab\/wp-content\/uploads\/sites\/10\/2026\/08\/Process-Control-Blog-Header-Image-scaled.jpg","datePublished":"2026-08-25T13:36:30+00:00","dateModified":"2026-08-25T13:36:33+00:00","author":{"@id":"https:\/\/admin.acceleratingscience.com\/life-in-the-lab\/#\/schema\/person\/4fcc1f6ee629bcf55630e406799baa05"},"description":"Learn how centralized process data and distributed control systems help biomanufacturers improve process control, scale-up, and tech transfer.","breadcrumb":{"@id":"https:\/\/www.thermofisher.com\/blog\/life-in-the-lab\/bioprocessing-single-use-process-control-scale-up\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.thermofisher.com\/blog\/life-in-the-lab\/bioprocessing-single-use-process-control-scale-up\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.thermofisher.com\/blog\/life-in-the-lab\/bioprocessing-single-use-process-control-scale-up\/#primaryimage","url":"https:\/\/admin.acceleratingscience.com\/life-in-the-lab\/wp-content\/uploads\/sites\/10\/2026\/08\/Process-Control-Blog-Header-Image-scaled.jpg","contentUrl":"https:\/\/admin.acceleratingscience.com\/life-in-the-lab\/wp-content\/uploads\/sites\/10\/2026\/08\/Process-Control-Blog-Header-Image-scaled.jpg","width":2560,"height":1506,"caption":"Process-Control-Blog-Header-Image-scaled"},{"@type":"BreadcrumbList","@id":"https:\/\/www.thermofisher.com\/blog\/life-in-the-lab\/bioprocessing-single-use-process-control-scale-up\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/admin.acceleratingscience.com\/life-in-the-lab\/"},{"@type":"ListItem","position":2,"name":"How can biomanufacturers strengthen process control as they scale operations?"}]},{"@type":"WebSite","@id":"https:\/\/admin.acceleratingscience.com\/life-in-the-lab\/#website","url":"https:\/\/admin.acceleratingscience.com\/life-in-the-lab\/","name":"Life in the Lab","description":"","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/admin.acceleratingscience.com\/life-in-the-lab\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Person","@id":"https:\/\/admin.acceleratingscience.com\/life-in-the-lab\/#\/schema\/person\/4fcc1f6ee629bcf55630e406799baa05","name":"Chandra Trisuel Kamatham","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/secure.gravatar.com\/avatar\/bf386d486485be363eaf4625350d93db852a089f51ebf9c93d497cb3d7f73963?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/bf386d486485be363eaf4625350d93db852a089f51ebf9c93d497cb3d7f73963?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/bf386d486485be363eaf4625350d93db852a089f51ebf9c93d497cb3d7f73963?s=96&d=mm&r=g","caption":"Chandra Trisuel Kamatham"},"url":"https:\/\/admin.acceleratingscience.com\/author\/chandratrisuel-kamatham1thermofisher-com\/"}]}},"taxonomy_info":{"category":[{"value":24,"label":"Bioprocessing"}],"post_tag":[{"value":1599,"label":"Biomanufacturing process control"},{"value":1602,"label":"Biomanufacturing scale-up"},{"value":1504,"label":"bioprocess automation"},{"value":1601,"label":"Centralized process data"},{"value":1592,"label":"Distributed control system (DCS) \u2022"},{"value":1600,"label":"Process control"},{"value":1603,"label":"Process data management"},{"value":1234,"label":"tech transfer"}]},"featured_image_src_large":["https:\/\/admin.acceleratingscience.com\/life-in-the-lab\/wp-content\/uploads\/sites\/10\/2026\/08\/Process-Control-Blog-Header-Image-1024x602.jpg",760,447,true],"author_info":{"display_name":"Chandra Trisuel Kamatham","author_link":"https:\/\/admin.acceleratingscience.com\/author\/chandratrisuel-kamatham1thermofisher-com\/"},"comment_info":0,"category_info":[{"term_id":24,"name":"Bioprocessing","slug":"bioprocessing","term_group":0,"term_taxonomy_id":24,"taxonomy":"category","description":"","parent":0,"count":76,"filter":"raw","meta":[],"cat_ID":24,"category_count":76,"category_description":"","cat_name":"Bioprocessing","category_nicename":"bioprocessing","category_parent":0}],"tag_info":[{"term_id":1599,"name":"Biomanufacturing process control","slug":"biomanufacturing-process-control-2","term_group":0,"term_taxonomy_id":1599,"taxonomy":"post_tag","description":"","parent":0,"count":1,"filter":"raw","meta":[]},{"term_id":1602,"name":"Biomanufacturing scale-up","slug":"biomanufacturing-scale-up-2","term_group":0,"term_taxonomy_id":1602,"taxonomy":"post_tag","description":"","parent":0,"count":1,"filter":"raw","meta":[]},{"term_id":1504,"name":"bioprocess automation","slug":"bioprocess-automation","term_group":0,"term_taxonomy_id":1504,"taxonomy":"post_tag","description":"","parent":0,"count":2,"filter":"raw","meta":[]},{"term_id":1601,"name":"Centralized process data","slug":"centralized-process-data-2","term_group":0,"term_taxonomy_id":1601,"taxonomy":"post_tag","description":"","parent":0,"count":1,"filter":"raw","meta":[]},{"term_id":1592,"name":"Distributed control system (DCS) \u2022","slug":"distributed-control-system-dcs","term_group":0,"term_taxonomy_id":1592,"taxonomy":"post_tag","description":"","parent":0,"count":1,"filter":"raw","meta":[]},{"term_id":1600,"name":"Process control","slug":"process-control-2","term_group":0,"term_taxonomy_id":1600,"taxonomy":"post_tag","description":"","parent":0,"count":1,"filter":"raw","meta":[]},{"term_id":1603,"name":"Process data management","slug":"process-data-management-2","term_group":0,"term_taxonomy_id":1603,"taxonomy":"post_tag","description":"","parent":0,"count":1,"filter":"raw","meta":[]},{"term_id":1234,"name":"tech transfer","slug":"tech-transfer","term_group":0,"term_taxonomy_id":1234,"taxonomy":"post_tag","description":"","parent":0,"count":2,"filter":"raw","meta":[]}],"jetpack-related-posts":[],"jetpack_sharing_enabled":true,"jetpack_featured_media_url":"https:\/\/admin.acceleratingscience.com\/life-in-the-lab\/wp-content\/uploads\/sites\/10\/2026\/08\/Process-Control-Blog-Header-Image-scaled.jpg","_links":{"self":[{"href":"https:\/\/www.thermofisher.com\/blog\/life-in-the-lab\/wp-json\/wp\/v2\/posts\/8377","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.thermofisher.com\/blog\/life-in-the-lab\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.thermofisher.com\/blog\/life-in-the-lab\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/life-in-the-lab\/wp-json\/wp\/v2\/users\/1867"}],"replies":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/life-in-the-lab\/wp-json\/wp\/v2\/comments?post=8377"}],"version-history":[{"count":4,"href":"https:\/\/www.thermofisher.com\/blog\/life-in-the-lab\/wp-json\/wp\/v2\/posts\/8377\/revisions"}],"predecessor-version":[{"id":8605,"href":"https:\/\/www.thermofisher.com\/blog\/life-in-the-lab\/wp-json\/wp\/v2\/posts\/8377\/revisions\/8605"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/life-in-the-lab\/wp-json\/wp\/v2\/media\/8390"}],"wp:attachment":[{"href":"https:\/\/www.thermofisher.com\/blog\/life-in-the-lab\/wp-json\/wp\/v2\/media?parent=8377"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/life-in-the-lab\/wp-json\/wp\/v2\/categories?post=8377"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/life-in-the-lab\/wp-json\/wp\/v2\/tags?post=8377"},{"taxonomy":"division","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/life-in-the-lab\/wp-json\/wp\/v2\/division?post=8377"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}