{"id":10125,"date":"2019-04-09T12:00:16","date_gmt":"2019-04-09T12:00:16","guid":{"rendered":"https:\/\/www.thermofisher.com\/blog\/materials\/?p=10125"},"modified":"2026-09-18T14:44:03","modified_gmt":"2026-09-18T19:44:03","slug":"the-faqs-about-web-gauging","status":"publish","type":"post","link":"https:\/\/www.thermofisher.com\/blog\/materials\/the-faqs-about-web-gauging\/","title":{"rendered":"The FAQs about Web Gauging"},"content":{"rendered":"<p>Producers of plastic films, extrusion coatings, blown films, rubber\/vinyl, some building materials, lithium-ion batteries, and nonwovens use <a href=\"https:\/\/www.thermofisher.com\/us\/en\/home\/industrial\/manufacturing-processing\/measurement-control-systems\/moving-web-thickness-weight-measurement-systems.html?icid=CAD_blog_p2p_2019April\">web gauging technology<\/a> to make operations more efficient and minimize waste.\u00a0 Too much or too little coating of materials, or too thin or too thick dimensions, could hurt the performance of the product.\u00a0 Too much of a <a href=\"https:\/\/www.thermofisher.com\/us\/en\/home\/industrial\/manufacturing-processing\/measurement-control-systems\/metals-coating-weight-thickness-measurement-gauges.html?icid=CAD_blog_p2p_2019April\">coating<\/a> or extra thickness could also increase raw material costs and cut into the manufacturer\u2019s profits.\u00a0 Too thin or too little coating could cause sub-standard products that need to be tossed in the trash, which would increase scrap costs as well.<\/p>\n<p>A <a href=\"https:\/\/www.thermofisher.com\/us\/en\/home\/industrial\/manufacturing-processing\/measurement-control-systems\/moving-web-thickness-weight-measurement-systems.html?icid=CAD_blog_p2p_2019April\">Web Gauge <\/a>is a measurement and control system used for anything manufactured in a continuous web process. Web gauging systems help ensure efficient production of uniform, reliable, functional products, and help manufacturers meet stringent customer specifications and guarantee the performance of products. It also helps to make operations more efficient and minimize waste.<\/p>\n<p>If your company is thinking of purchasing a web gauging system, you probably have many questions about the various technologies available.\u00a0 We\u2019ve answered many of those questions on our website.\u00a0 Visit <a href=\"https:\/\/www.thermofisher.com\/us\/en\/home\/industrial\/manufacturing-processing\/online-non-contact-measurement-gauges\/-web-thickness-basis-weight-measurement\/web-gauging-solutions-faqs.html?icid=CAD_blog_p2p_2019April\">Web Gauging Solutions FAQs<\/a> to find the answers to these frequently asked questions about web gauging thickness and basis weight measurement systems:<\/p>\n<ul>\n<li>Why are thickness and basis weight measurement and control systems needed in continuous web manufacturing?<\/li>\n<li>Are there other benefits from using a web thickness measurement and control system?<\/li>\n<li>What is the typical payback period (ROI) of a web gauging system<\/li>\n<li>Are there special considerations for nonwovens?<\/li>\n<li>Are there special considerations for building materials?<\/li>\n<li>Are there special considerations for extrusion?<\/li>\n<li>Are there special considerations for coating and converting?<\/li>\n<li>Are there special considerations for rubber calendering?<\/li>\n<li>Are there special considerations for lithium-ion batteries?<\/li>\n<\/ul>\n<p>Read the answers to these questions, as well as access videos and product comparison tables on our <a href=\"https:\/\/www.thermofisher.com\/us\/en\/home\/industrial\/manufacturing-processing\/online-non-contact-measurement-gauges\/-web-thickness-basis-weight-measurement\/web-gauging-solutions-faqs.html?icid=CAD_blog_p2p_2019April\">Web Gauging Solutions FAQs<\/a> page.<\/p>\n<p><em>Editor\u2019s Note:\u00a0 If you want to learn more about the technology, feel free to download our free ebook: <\/em><a href=\"https:\/\/www.thermofisher.com\/us\/en\/home\/global\/forms\/industrial\/web-gauging-ebook-registration-form.html?icid=CAD_blog_p2p_2019April\"><em>What you need to know about Web Gauging Systems<\/em><\/a><em>. It includes easy-to-understand explanations of the technology, benefits, and economics of web gauging systems, as well as why they are typically used. <\/em><\/p>\n<p><em>Access the ebook: <\/em><a href=\"https:\/\/www.thermofisher.com\/us\/en\/home\/global\/forms\/industrial\/web-gauging-ebook-registration-form.html?icid=CAD_blog_p2p_2019April\"><em>What you need to know about Web Gauging Systems<\/em><\/a><\/p>\n<p><a href=\"https:\/\/www.thermofisher.com\/us\/en\/home\/global\/forms\/industrial\/web-gauging-ebook-registration-form.html?icid=CAD_MM_Gauging_FeaturedWebGaugingEBook_blog\"><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter size-full wp-image-10208\" src=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/7\/2019\/04\/CAD-Web-Gauging-eBook-E-Signature-Banner-700x125b.png\" alt=\"Download free web gauging ebook\" width=\"700\" height=\"125\" srcset=\"https:\/\/admin.acceleratingscience.com\/materials\/wp-content\/uploads\/sites\/7\/2019\/04\/CAD-Web-Gauging-eBook-E-Signature-Banner-700x125b.png 700w, https:\/\/admin.acceleratingscience.com\/materials\/wp-content\/uploads\/sites\/7\/2019\/04\/CAD-Web-Gauging-eBook-E-Signature-Banner-700x125b-300x54.png 300w\" sizes=\"auto, (max-width: 700px) 100vw, 700px\" \/><\/a><\/p>\n","protected":false},"excerpt":{"rendered":"<p>Producers of plastic films, extrusion coatings, blown films, rubber\/vinyl, some building materials, lithium-ion batteries, and nonwovens use web gauging technology to make operations more efficient and minimize waste.\u00a0 Too much or too little coating of materials, or too thin or too thick dimensions, could hurt the performance of the product.\u00a0 Too much of a coating<\/p>\n","protected":false},"author":60,"featured_media":10141,"comment_status":"open","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_monsterinsights_skip_tracking":false,"_genesis_hide_title":false,"_genesis_hide_breadcrumbs":false,"_genesis_hide_singular_image":false,"_genesis_hide_footer_widgets":false,"_genesis_custom_body_class":"","_genesis_custom_post_class":"","_genesis_layout":"","footnotes":""},"categories":[960,961,21],"tags":[938,941,942,955],"division":[],"class_list":["post-10125","post","type-post","status-publish","format-standard","has-post-thumbnail","category-manufacturing-processing","category-process-control","category-quality-control-and-assurance-verification","tag-ceramics-glass","tag-electronics-semiconductors","tag-energy-materials","tag-polymer-plastics","entry"],"_selected_authors":[1576],"_selected_reviewers":[],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v28.9 (Yoast SEO v28.9) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>The FAQs about Web Gauging - Advancing Materials<\/title>\n<meta name=\"description\" content=\"Get answers to common web gauging questions and learn how these systems measure thickness, basis weight, and coatings for process and quality control.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.thermofisher.com\/blog\/materials\/the-faqs-about-web-gauging\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"The FAQs about Web Gauging\" \/>\n<meta property=\"og:description\" content=\"Get answers to common web gauging questions and learn how these systems measure thickness, basis weight, and coatings for process and quality control.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.thermofisher.com\/blog\/materials\/the-faqs-about-web-gauging\/\" \/>\n<meta property=\"og:site_name\" content=\"Advancing Materials\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/thermofisher\" \/>\n<meta property=\"article:published_time\" content=\"2019-04-09T12:00:16+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2026-09-18T19:44:03+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/admin.acceleratingscience.com\/materials\/wp-content\/uploads\/sites\/7\/2019\/04\/faqs.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"698\" \/>\n\t<meta property=\"og:image:height\" content=\"384\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"Tracey Sinha-Spinks\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:creator\" content=\"@thermofisher\" \/>\n<meta name=\"twitter:site\" content=\"@thermofisher\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Tracey Sinha-Spinks\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"3 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/materials\\\/the-faqs-about-web-gauging\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/materials\\\/the-faqs-about-web-gauging\\\/\"},\"author\":{\"name\":\"Tracey Sinha-Spinks\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/materials\\\/#\\\/schema\\\/person\\\/7180a02a41298a0e0deb0f49fd1620f2\"},\"headline\":\"The FAQs about Web Gauging\",\"datePublished\":\"2019-04-09T12:00:16+00:00\",\"dateModified\":\"2026-09-18T19:44:03+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/materials\\\/the-faqs-about-web-gauging\\\/\"},\"wordCount\":375,\"commentCount\":0,\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/materials\\\/the-faqs-about-web-gauging\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/materials\\\/wp-content\\\/uploads\\\/sites\\\/7\\\/2019\\\/04\\\/faqs.jpg\",\"keywords\":[\"Ceramics\\\/Glass\",\"Electronics\\\/Semiconductors\",\"Energy Materials\",\"Polymer\\\/Plastics\"],\"articleSection\":[\"Manufacturing and Processing\",\"Process Control\",\"QA\\\/QC Verification\"],\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/materials\\\/the-faqs-about-web-gauging\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/materials\\\/the-faqs-about-web-gauging\\\/\",\"url\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/materials\\\/the-faqs-about-web-gauging\\\/\",\"name\":\"The FAQs about Web Gauging - Advancing Materials\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/materials\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/materials\\\/the-faqs-about-web-gauging\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/materials\\\/the-faqs-about-web-gauging\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/materials\\\/wp-content\\\/uploads\\\/sites\\\/7\\\/2019\\\/04\\\/faqs.jpg\",\"datePublished\":\"2019-04-09T12:00:16+00:00\",\"dateModified\":\"2026-09-18T19:44:03+00:00\",\"author\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/materials\\\/#\\\/schema\\\/person\\\/7180a02a41298a0e0deb0f49fd1620f2\"},\"description\":\"Get answers to common web gauging questions and learn how these systems measure thickness, basis weight, and coatings for process and quality control.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/materials\\\/the-faqs-about-web-gauging\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/materials\\\/the-faqs-about-web-gauging\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/materials\\\/the-faqs-about-web-gauging\\\/#primaryimage\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/materials\\\/wp-content\\\/uploads\\\/sites\\\/7\\\/2019\\\/04\\\/faqs.jpg\",\"contentUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/materials\\\/wp-content\\\/uploads\\\/sites\\\/7\\\/2019\\\/04\\\/faqs.jpg\",\"width\":698,\"height\":384,\"caption\":\"rolls of colored vinyl and films\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/materials\\\/the-faqs-about-web-gauging\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/materials\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"The FAQs about Web Gauging\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/materials\\\/#website\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/materials\\\/\",\"name\":\"Advancing Materials\",\"description\":\"Spectroscopy, spectrometry, and materials science stories and solutions about advancing research and improving product development\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/materials\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/materials\\\/#\\\/schema\\\/person\\\/7180a02a41298a0e0deb0f49fd1620f2\",\"name\":\"Tracey Sinha-Spinks\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/431cca04c22f1b34637b6e5f3d1d2f7ad802acd3a4e32bde2782ecceb519b918?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/431cca04c22f1b34637b6e5f3d1d2f7ad802acd3a4e32bde2782ecceb519b918?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/431cca04c22f1b34637b6e5f3d1d2f7ad802acd3a4e32bde2782ecceb519b918?s=96&d=mm&r=g\",\"caption\":\"Tracey Sinha-Spinks\"},\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/author\\\/tracey-sinhaspinks\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"The FAQs about Web Gauging - Advancing Materials","description":"Get answers to common web gauging questions and learn how these systems measure thickness, basis weight, and coatings for process and quality control.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.thermofisher.com\/blog\/materials\/the-faqs-about-web-gauging\/","og_locale":"en_US","og_type":"article","og_title":"The FAQs about Web Gauging","og_description":"Get answers to common web gauging questions and learn how these systems measure thickness, basis weight, and coatings for process and quality control.","og_url":"https:\/\/www.thermofisher.com\/blog\/materials\/the-faqs-about-web-gauging\/","og_site_name":"Advancing Materials","article_publisher":"https:\/\/www.facebook.com\/thermofisher","article_published_time":"2019-04-09T12:00:16+00:00","article_modified_time":"2026-09-18T19:44:03+00:00","og_image":[{"width":698,"height":384,"url":"https:\/\/admin.acceleratingscience.com\/materials\/wp-content\/uploads\/sites\/7\/2019\/04\/faqs.jpg","type":"image\/jpeg"}],"author":"Tracey Sinha-Spinks","twitter_card":"summary_large_image","twitter_creator":"@thermofisher","twitter_site":"@thermofisher","twitter_misc":{"Written by":"Tracey Sinha-Spinks","Est. reading time":"3 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.thermofisher.com\/blog\/materials\/the-faqs-about-web-gauging\/#article","isPartOf":{"@id":"https:\/\/www.thermofisher.com\/blog\/materials\/the-faqs-about-web-gauging\/"},"author":{"name":"Tracey Sinha-Spinks","@id":"https:\/\/admin.acceleratingscience.com\/materials\/#\/schema\/person\/7180a02a41298a0e0deb0f49fd1620f2"},"headline":"The FAQs about Web Gauging","datePublished":"2019-04-09T12:00:16+00:00","dateModified":"2026-09-18T19:44:03+00:00","mainEntityOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/materials\/the-faqs-about-web-gauging\/"},"wordCount":375,"commentCount":0,"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/materials\/the-faqs-about-web-gauging\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/materials\/wp-content\/uploads\/sites\/7\/2019\/04\/faqs.jpg","keywords":["Ceramics\/Glass","Electronics\/Semiconductors","Energy Materials","Polymer\/Plastics"],"articleSection":["Manufacturing and Processing","Process Control","QA\/QC Verification"],"inLanguage":"en-US","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/www.thermofisher.com\/blog\/materials\/the-faqs-about-web-gauging\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/www.thermofisher.com\/blog\/materials\/the-faqs-about-web-gauging\/","url":"https:\/\/www.thermofisher.com\/blog\/materials\/the-faqs-about-web-gauging\/","name":"The FAQs about Web Gauging - Advancing Materials","isPartOf":{"@id":"https:\/\/admin.acceleratingscience.com\/materials\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/materials\/the-faqs-about-web-gauging\/#primaryimage"},"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/materials\/the-faqs-about-web-gauging\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/materials\/wp-content\/uploads\/sites\/7\/2019\/04\/faqs.jpg","datePublished":"2019-04-09T12:00:16+00:00","dateModified":"2026-09-18T19:44:03+00:00","author":{"@id":"https:\/\/admin.acceleratingscience.com\/materials\/#\/schema\/person\/7180a02a41298a0e0deb0f49fd1620f2"},"description":"Get answers to common web gauging questions and learn how these systems measure thickness, basis weight, and coatings for process and quality control.","breadcrumb":{"@id":"https:\/\/www.thermofisher.com\/blog\/materials\/the-faqs-about-web-gauging\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.thermofisher.com\/blog\/materials\/the-faqs-about-web-gauging\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.thermofisher.com\/blog\/materials\/the-faqs-about-web-gauging\/#primaryimage","url":"https:\/\/admin.acceleratingscience.com\/materials\/wp-content\/uploads\/sites\/7\/2019\/04\/faqs.jpg","contentUrl":"https:\/\/admin.acceleratingscience.com\/materials\/wp-content\/uploads\/sites\/7\/2019\/04\/faqs.jpg","width":698,"height":384,"caption":"rolls of colored vinyl and films"},{"@type":"BreadcrumbList","@id":"https:\/\/www.thermofisher.com\/blog\/materials\/the-faqs-about-web-gauging\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/admin.acceleratingscience.com\/materials\/"},{"@type":"ListItem","position":2,"name":"The FAQs about Web Gauging"}]},{"@type":"WebSite","@id":"https:\/\/admin.acceleratingscience.com\/materials\/#website","url":"https:\/\/admin.acceleratingscience.com\/materials\/","name":"Advancing Materials","description":"Spectroscopy, spectrometry, and materials science stories and solutions about advancing research and improving product development","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/admin.acceleratingscience.com\/materials\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Person","@id":"https:\/\/admin.acceleratingscience.com\/materials\/#\/schema\/person\/7180a02a41298a0e0deb0f49fd1620f2","name":"Tracey Sinha-Spinks","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/secure.gravatar.com\/avatar\/431cca04c22f1b34637b6e5f3d1d2f7ad802acd3a4e32bde2782ecceb519b918?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/431cca04c22f1b34637b6e5f3d1d2f7ad802acd3a4e32bde2782ecceb519b918?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/431cca04c22f1b34637b6e5f3d1d2f7ad802acd3a4e32bde2782ecceb519b918?s=96&d=mm&r=g","caption":"Tracey Sinha-Spinks"},"url":"https:\/\/admin.acceleratingscience.com\/author\/tracey-sinhaspinks\/"}]}},"taxonomy_info":{"category":[{"value":960,"label":"Manufacturing and Processing"},{"value":961,"label":"Process Control"},{"value":21,"label":"QA\/QC Verification"}],"post_tag":[{"value":938,"label":"Ceramics\/Glass"},{"value":941,"label":"Electronics\/Semiconductors"},{"value":942,"label":"Energy Materials"},{"value":955,"label":"Polymer\/Plastics"}]},"featured_image_src_large":["https:\/\/admin.acceleratingscience.com\/materials\/wp-content\/uploads\/sites\/7\/2019\/04\/faqs.jpg",698,384,false],"author_info":{"display_name":"Tracey Sinha-Spinks","author_link":"https:\/\/admin.acceleratingscience.com\/author\/tracey-sinhaspinks\/"},"comment_info":0,"category_info":[{"term_id":960,"name":"Manufacturing and Processing","slug":"manufacturing-processing","term_group":0,"term_taxonomy_id":960,"taxonomy":"category","description":"","parent":0,"count":116,"filter":"raw","meta":[],"cat_ID":960,"category_count":116,"category_description":"","cat_name":"Manufacturing and Processing","category_nicename":"manufacturing-processing","category_parent":0},{"term_id":961,"name":"Process Control","slug":"process-control","term_group":0,"term_taxonomy_id":961,"taxonomy":"category","description":"","parent":0,"count":91,"filter":"raw","meta":[],"cat_ID":961,"category_count":91,"category_description":"","cat_name":"Process Control","category_nicename":"process-control","category_parent":0},{"term_id":21,"name":"QA\/QC Verification","slug":"quality-control-and-assurance-verification","term_group":0,"term_taxonomy_id":21,"taxonomy":"category","description":"","parent":0,"count":132,"filter":"raw","meta":[],"cat_ID":21,"category_count":132,"category_description":"","cat_name":"QA\/QC Verification","category_nicename":"quality-control-and-assurance-verification","category_parent":0}],"tag_info":[{"term_id":938,"name":"Ceramics\/Glass","slug":"ceramics-glass","term_group":0,"term_taxonomy_id":938,"taxonomy":"post_tag","description":"","parent":0,"count":11,"filter":"raw","meta":[]},{"term_id":941,"name":"Electronics\/Semiconductors","slug":"electronics-semiconductors","term_group":0,"term_taxonomy_id":941,"taxonomy":"post_tag","description":"","parent":0,"count":34,"filter":"raw","meta":[]},{"term_id":942,"name":"Energy Materials","slug":"energy-materials","term_group":0,"term_taxonomy_id":942,"taxonomy":"post_tag","description":"","parent":0,"count":29,"filter":"raw","meta":[]},{"term_id":955,"name":"Polymer\/Plastics","slug":"polymer-plastics","term_group":0,"term_taxonomy_id":955,"taxonomy":"post_tag","description":"","parent":0,"count":221,"filter":"raw","meta":[]}],"_links":{"self":[{"href":"https:\/\/www.thermofisher.com\/blog\/materials\/wp-json\/wp\/v2\/posts\/10125","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.thermofisher.com\/blog\/materials\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.thermofisher.com\/blog\/materials\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/materials\/wp-json\/wp\/v2\/users\/60"}],"replies":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/materials\/wp-json\/wp\/v2\/comments?post=10125"}],"version-history":[{"count":0,"href":"https:\/\/www.thermofisher.com\/blog\/materials\/wp-json\/wp\/v2\/posts\/10125\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/materials\/wp-json\/wp\/v2\/media\/10141"}],"wp:attachment":[{"href":"https:\/\/www.thermofisher.com\/blog\/materials\/wp-json\/wp\/v2\/media?parent=10125"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/materials\/wp-json\/wp\/v2\/categories?post=10125"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/materials\/wp-json\/wp\/v2\/tags?post=10125"},{"taxonomy":"division","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/materials\/wp-json\/wp\/v2\/division?post=10125"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}