{"id":10975,"date":"2021-02-16T14:00:25","date_gmt":"2021-02-16T20:00:25","guid":{"rendered":"https:\/\/admin.acceleratingscience.com\/materials\/?p=10975"},"modified":"2021-05-28T18:06:10","modified_gmt":"2021-05-28T23:06:10","slug":"choosing-the-right-uv-vis","status":"publish","type":"post","link":"https:\/\/www.thermofisher.com\/blog\/materials\/choosing-the-right-uv-vis\/","title":{"rendered":"Choosing the Right UV-Vis"},"content":{"rendered":"<p>Twenty years ago, molecular biologists were introduced to a breakthrough method for quantifying nucleic acid: our Thermo Scientific NanoDrop 1000, a microvolume UV-Vis spectrophotometer. While some labs continue to use the original NanoDrop 1000, advancements have been made to UV-Vis systems to make them as efficient as possible for your specific needs. Learning about their differentiators makes upgrading to new models a seemingly time-consuming and difficult task. Luckily, we\u2019ve compiled seven key factors to simplify the process.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"wp-image-10976 aligncenter\" title=\"Thermo Scientific NanoDrop UV Vis Spectrophotometer\" src=\"https:\/\/admin.acceleratingscience.com\/materials\/wp-content\/uploads\/sites\/7\/2021\/02\/NanoDrop1000.jpg\" alt=\"Thermo Scientific NanoDrop UV Vis Spectrophotometer\" width=\"337\" height=\"300\" srcset=\"https:\/\/admin.acceleratingscience.com\/materials\/wp-content\/uploads\/sites\/7\/2021\/02\/NanoDrop1000.jpg 487w, https:\/\/admin.acceleratingscience.com\/materials\/wp-content\/uploads\/sites\/7\/2021\/02\/NanoDrop1000-300x267.jpg 300w\" sizes=\"auto, (max-width: 337px) 100vw, 337px\" \/><\/p>\n<h2 style=\"font-size: 50%;color: white;height: 5px\">UV Vis instrument selection criteria<\/h2>\n<p>First, determine if and how the following technological specifications impact your research:<\/p>\n<ol>\n<li><strong>Detection Limits<\/strong>: These limits influence how much you&#8217;ll need to dilute your sample, if at all, to conduct analysis. The wider the detection limits\u2019 dynamic range, the less time you\u2019ll spend measuring samples and the more time you\u2019ll spend deriving results from data.<\/li>\n<li><strong>Contaminant assessment and specificity<\/strong>: Ensure the instrument provides enough insight into the specific sample types you intend to use. Specifically, the spectrophotometer should be able to measure sample concentration and sample purity to ensure you\u2019re working with quality starting material before downstream activities begin.<\/li>\n<li><strong>Instrument flexibility<\/strong>: There can be any number of user scenarios in a lab \u2013 gloved hands, remote PC control, limited bench space, compliance requirements, etc. \u2013 and you\u2019ll want to ensure your instrument system accommodates them.<\/li>\n<li><strong>Data integrity and compliance needs<\/strong>: Ensuring the integrity of data is important to all labs but is a critical component for labs that need to comply with the US FDA\u2019s 21 CFR Part 11 code and similar regulations.<\/li>\n<\/ol>\n<p>Once you\u2019ve found a UV-Vis solution that fits your specific research needs, examine the factors that impact the reliability, longevity, and ROI of your system:<\/p>\n<ol start=\"5\">\n<li><strong>Serviceability and maintenance<\/strong>: Determine if the maintenance requirements and validation of the instrument system makes sense for your situation. Consider the simplicity (or difficulty) of routine calibration, simple diagnostics, whether the system is manufactured in compliance with ISO, and part availability.<\/li>\n<li><strong>Customer support<\/strong>: While often overlooked, system downtime is costly for any lab and it\u2019s important to ensure the manufacturer of the instrument you choose has timely service response and knowledgeable service personnel who are supported by online resources (application notes, software updates, manuals, etc.).<\/li>\n<li><strong>Company history and reputation<\/strong>: When spectrophotometers come from a long-time manufacturer, the manufacturer is likely familiar with your needs. A company\u2019s longevity also ensures they can support your system for years to come.<\/li>\n<\/ol>\n<p>For more detailed information about how these 7 factors influence your specific research considerations, visit our <a href=\"https:\/\/www.thermofisher.com\/us\/en\/home\/products-and-services\/promotions\/industrial\/7-considerations-purchasing-microvolume-uv-vis-instrument.html?cid=fl-NanoDrop7\">online purchasing guide<\/a>.<\/p>\n<p>To explore whether one of our NanoDrop Microvolume instruments might be the right fit for your lab, visit our <a href=\"https:\/\/www.thermofisher.com\/us\/en\/home\/industrial\/spectroscopy-elemental-isotope-analysis\/molecular-spectroscopy\/ultraviolet-visible-visible-spectrophotometry-uv-vis-vis\/uv-vis-vis-instruments\/nanodrop-microvolume-spectrophotometers\/nanodrop-products-guide.html\">online product guide<\/a>.<\/p>\n<p><em>Patrick Brown is the product marketing specialist for the Thermo Scientific NanoDrop Microvolume UV-Vis spectrophotometers.<\/em><\/p>\n<p><em>\/\/\/<\/em><\/p>\n<p><em>\u00a0<\/em><a href=\"https:\/\/www.thermofisher.com\/blog\/microscopy\/subscribe-to-accelerating-microscopy\/\">Subscribe now<\/a> to receive Accelerating Microscopy updates straight to your inbox.<\/p>\n<p>Speak with an expert: <a href=\"https:\/\/www.thermofisher.com\/blog\/microscopy\/speak-with-an-expert\/\">https:\/\/www.thermofisher.com\/blog\/microscopy\/speak-with-an-expert\/<\/a><\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Twenty years ago, molecular biologists were introduced to a breakthrough method for quantifying nucleic acid: our Thermo Scientific NanoDrop 1000, a microvolume UV-Vis spectrophotometer. While some labs continue to use the original NanoDrop 1000, advancements have been made to UV-Vis systems to make them as efficient as possible for your specific needs. Learning about their<\/p>\n","protected":false},"author":1299,"featured_media":10986,"comment_status":"open","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_monsterinsights_skip_tracking":false,"_genesis_hide_title":false,"_genesis_hide_breadcrumbs":false,"_genesis_hide_singular_image":false,"_genesis_hide_footer_widgets":false,"_genesis_custom_body_class":"","_genesis_custom_post_class":"","_genesis_layout":"","footnotes":""},"categories":[968,980],"tags":[],"division":[],"class_list":["post-10975","post","type-post","status-publish","format-standard","has-post-thumbnail","category-spectroscopy-spectrometry","category-uv-vis","entry"],"_selected_authors":"","_selected_reviewers":"","acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v27.8 (Yoast SEO v27.8) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>UV Vis - Choosing a UV Vis - UV Vis Detection Limit - Advancing Materials<\/title>\n<meta name=\"description\" content=\"Choose the right UV vis spectrophotometer based on instrument detection limits, flexibility, data integrity, serviceability, and more.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.thermofisher.com\/blog\/materials\/choosing-the-right-uv-vis\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Choosing the Right UV-Vis\" \/>\n<meta property=\"og:description\" content=\"Choose the right UV vis spectrophotometer based on instrument detection limits, flexibility, data integrity, serviceability, and more.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.thermofisher.com\/blog\/materials\/choosing-the-right-uv-vis\/\" \/>\n<meta property=\"og:site_name\" content=\"Advancing Materials\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/thermofisher\" \/>\n<meta property=\"article:published_time\" content=\"2021-02-16T20:00:25+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2021-05-28T23:06:10+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/admin.acceleratingscience.com\/materials\/wp-content\/uploads\/sites\/7\/2021\/02\/spec_preferred_uvvis.png\" \/>\n\t<meta property=\"og:image:width\" content=\"534\" \/>\n\t<meta property=\"og:image:height\" content=\"510\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/png\" \/>\n<meta name=\"author\" content=\"Patrick Brown\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:creator\" content=\"@thermofisher\" \/>\n<meta name=\"twitter:site\" content=\"@thermofisher\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Patrick Brown\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"2 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/materials\\\/choosing-the-right-uv-vis\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/materials\\\/choosing-the-right-uv-vis\\\/\"},\"author\":{\"name\":\"Patrick Brown\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/materials\\\/#\\\/schema\\\/person\\\/ffe76140402969b3c5d5b989b00bb3b7\"},\"headline\":\"Choosing the Right UV-Vis\",\"datePublished\":\"2021-02-16T20:00:25+00:00\",\"dateModified\":\"2021-05-28T23:06:10+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/materials\\\/choosing-the-right-uv-vis\\\/\"},\"wordCount\":485,\"commentCount\":0,\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/materials\\\/choosing-the-right-uv-vis\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/materials\\\/wp-content\\\/uploads\\\/sites\\\/7\\\/2021\\\/02\\\/spec_preferred_uvvis.png\",\"articleSection\":[\"Spectroscopy and Spectrometry\",\"UV Vis\"],\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/materials\\\/choosing-the-right-uv-vis\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/materials\\\/choosing-the-right-uv-vis\\\/\",\"url\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/materials\\\/choosing-the-right-uv-vis\\\/\",\"name\":\"UV Vis - Choosing a UV Vis - UV Vis Detection Limit - Advancing Materials\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/materials\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/materials\\\/choosing-the-right-uv-vis\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/materials\\\/choosing-the-right-uv-vis\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/materials\\\/wp-content\\\/uploads\\\/sites\\\/7\\\/2021\\\/02\\\/spec_preferred_uvvis.png\",\"datePublished\":\"2021-02-16T20:00:25+00:00\",\"dateModified\":\"2021-05-28T23:06:10+00:00\",\"author\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/materials\\\/#\\\/schema\\\/person\\\/ffe76140402969b3c5d5b989b00bb3b7\"},\"description\":\"Choose the right UV vis spectrophotometer based on instrument detection limits, flexibility, data integrity, serviceability, and more.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/materials\\\/choosing-the-right-uv-vis\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/materials\\\/choosing-the-right-uv-vis\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/materials\\\/choosing-the-right-uv-vis\\\/#primaryimage\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/materials\\\/wp-content\\\/uploads\\\/sites\\\/7\\\/2021\\\/02\\\/spec_preferred_uvvis.png\",\"contentUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/materials\\\/wp-content\\\/uploads\\\/sites\\\/7\\\/2021\\\/02\\\/spec_preferred_uvvis.png\",\"width\":534,\"height\":510},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/materials\\\/choosing-the-right-uv-vis\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/materials\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Choosing the Right UV-Vis\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/materials\\\/#website\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/materials\\\/\",\"name\":\"Advancing Materials\",\"description\":\"Spectroscopy, spectrometry, and materials science stories and solutions about advancing research and improving product development\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/materials\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/materials\\\/#\\\/schema\\\/person\\\/ffe76140402969b3c5d5b989b00bb3b7\",\"name\":\"Patrick Brown\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/52238d742506f0bdc1a9f24444e70649148d5f42fcf8647ea0e94b34108f57a1?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/52238d742506f0bdc1a9f24444e70649148d5f42fcf8647ea0e94b34108f57a1?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/52238d742506f0bdc1a9f24444e70649148d5f42fcf8647ea0e94b34108f57a1?s=96&d=mm&r=g\",\"caption\":\"Patrick Brown\"},\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/author\\\/patrickbrown\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"UV Vis - Choosing a UV Vis - UV Vis Detection Limit - Advancing Materials","description":"Choose the right UV vis spectrophotometer based on instrument detection limits, flexibility, data integrity, serviceability, and more.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.thermofisher.com\/blog\/materials\/choosing-the-right-uv-vis\/","og_locale":"en_US","og_type":"article","og_title":"Choosing the Right UV-Vis","og_description":"Choose the right UV vis spectrophotometer based on instrument detection limits, flexibility, data integrity, serviceability, and more.","og_url":"https:\/\/www.thermofisher.com\/blog\/materials\/choosing-the-right-uv-vis\/","og_site_name":"Advancing Materials","article_publisher":"https:\/\/www.facebook.com\/thermofisher","article_published_time":"2021-02-16T20:00:25+00:00","article_modified_time":"2021-05-28T23:06:10+00:00","og_image":[{"width":534,"height":510,"url":"https:\/\/admin.acceleratingscience.com\/materials\/wp-content\/uploads\/sites\/7\/2021\/02\/spec_preferred_uvvis.png","type":"image\/png"}],"author":"Patrick Brown","twitter_card":"summary_large_image","twitter_creator":"@thermofisher","twitter_site":"@thermofisher","twitter_misc":{"Written by":"Patrick Brown","Est. reading time":"2 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.thermofisher.com\/blog\/materials\/choosing-the-right-uv-vis\/#article","isPartOf":{"@id":"https:\/\/www.thermofisher.com\/blog\/materials\/choosing-the-right-uv-vis\/"},"author":{"name":"Patrick Brown","@id":"https:\/\/admin.acceleratingscience.com\/materials\/#\/schema\/person\/ffe76140402969b3c5d5b989b00bb3b7"},"headline":"Choosing the Right UV-Vis","datePublished":"2021-02-16T20:00:25+00:00","dateModified":"2021-05-28T23:06:10+00:00","mainEntityOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/materials\/choosing-the-right-uv-vis\/"},"wordCount":485,"commentCount":0,"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/materials\/choosing-the-right-uv-vis\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/materials\/wp-content\/uploads\/sites\/7\/2021\/02\/spec_preferred_uvvis.png","articleSection":["Spectroscopy and Spectrometry","UV Vis"],"inLanguage":"en-US","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/www.thermofisher.com\/blog\/materials\/choosing-the-right-uv-vis\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/www.thermofisher.com\/blog\/materials\/choosing-the-right-uv-vis\/","url":"https:\/\/www.thermofisher.com\/blog\/materials\/choosing-the-right-uv-vis\/","name":"UV Vis - Choosing a UV Vis - UV Vis Detection Limit - Advancing Materials","isPartOf":{"@id":"https:\/\/admin.acceleratingscience.com\/materials\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/materials\/choosing-the-right-uv-vis\/#primaryimage"},"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/materials\/choosing-the-right-uv-vis\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/materials\/wp-content\/uploads\/sites\/7\/2021\/02\/spec_preferred_uvvis.png","datePublished":"2021-02-16T20:00:25+00:00","dateModified":"2021-05-28T23:06:10+00:00","author":{"@id":"https:\/\/admin.acceleratingscience.com\/materials\/#\/schema\/person\/ffe76140402969b3c5d5b989b00bb3b7"},"description":"Choose the right UV vis spectrophotometer based on instrument detection limits, flexibility, data integrity, serviceability, and more.","breadcrumb":{"@id":"https:\/\/www.thermofisher.com\/blog\/materials\/choosing-the-right-uv-vis\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.thermofisher.com\/blog\/materials\/choosing-the-right-uv-vis\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.thermofisher.com\/blog\/materials\/choosing-the-right-uv-vis\/#primaryimage","url":"https:\/\/admin.acceleratingscience.com\/materials\/wp-content\/uploads\/sites\/7\/2021\/02\/spec_preferred_uvvis.png","contentUrl":"https:\/\/admin.acceleratingscience.com\/materials\/wp-content\/uploads\/sites\/7\/2021\/02\/spec_preferred_uvvis.png","width":534,"height":510},{"@type":"BreadcrumbList","@id":"https:\/\/www.thermofisher.com\/blog\/materials\/choosing-the-right-uv-vis\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/admin.acceleratingscience.com\/materials\/"},{"@type":"ListItem","position":2,"name":"Choosing the Right UV-Vis"}]},{"@type":"WebSite","@id":"https:\/\/admin.acceleratingscience.com\/materials\/#website","url":"https:\/\/admin.acceleratingscience.com\/materials\/","name":"Advancing Materials","description":"Spectroscopy, spectrometry, and materials science stories and solutions about advancing research and improving product development","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/admin.acceleratingscience.com\/materials\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Person","@id":"https:\/\/admin.acceleratingscience.com\/materials\/#\/schema\/person\/ffe76140402969b3c5d5b989b00bb3b7","name":"Patrick Brown","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/secure.gravatar.com\/avatar\/52238d742506f0bdc1a9f24444e70649148d5f42fcf8647ea0e94b34108f57a1?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/52238d742506f0bdc1a9f24444e70649148d5f42fcf8647ea0e94b34108f57a1?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/52238d742506f0bdc1a9f24444e70649148d5f42fcf8647ea0e94b34108f57a1?s=96&d=mm&r=g","caption":"Patrick Brown"},"url":"https:\/\/admin.acceleratingscience.com\/author\/patrickbrown\/"}]}},"taxonomy_info":{"category":[{"value":968,"label":"Spectroscopy and Spectrometry"},{"value":980,"label":"UV Vis"}]},"featured_image_src_large":["https:\/\/admin.acceleratingscience.com\/materials\/wp-content\/uploads\/sites\/7\/2021\/02\/spec_preferred_uvvis.png",534,510,false],"author_info":{"display_name":"Patrick Brown","author_link":"https:\/\/admin.acceleratingscience.com\/author\/patrickbrown\/"},"comment_info":0,"category_info":[{"term_id":968,"name":"Spectroscopy and Spectrometry","slug":"spectroscopy-spectrometry","term_group":0,"term_taxonomy_id":968,"taxonomy":"category","description":"","parent":0,"count":222,"filter":"raw","meta":[],"cat_ID":968,"category_count":222,"category_description":"","cat_name":"Spectroscopy and Spectrometry","category_nicename":"spectroscopy-spectrometry","category_parent":0},{"term_id":980,"name":"UV Vis","slug":"uv-vis","term_group":0,"term_taxonomy_id":980,"taxonomy":"category","description":"","parent":968,"count":9,"filter":"raw","meta":[],"cat_ID":980,"category_count":9,"category_description":"","cat_name":"UV Vis","category_nicename":"uv-vis","category_parent":968}],"tag_info":false,"_links":{"self":[{"href":"https:\/\/www.thermofisher.com\/blog\/materials\/wp-json\/wp\/v2\/posts\/10975","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.thermofisher.com\/blog\/materials\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.thermofisher.com\/blog\/materials\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/materials\/wp-json\/wp\/v2\/users\/1299"}],"replies":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/materials\/wp-json\/wp\/v2\/comments?post=10975"}],"version-history":[{"count":0,"href":"https:\/\/www.thermofisher.com\/blog\/materials\/wp-json\/wp\/v2\/posts\/10975\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/materials\/wp-json\/wp\/v2\/media\/10986"}],"wp:attachment":[{"href":"https:\/\/www.thermofisher.com\/blog\/materials\/wp-json\/wp\/v2\/media?parent=10975"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/materials\/wp-json\/wp\/v2\/categories?post=10975"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/materials\/wp-json\/wp\/v2\/tags?post=10975"},{"taxonomy":"division","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/materials\/wp-json\/wp\/v2\/division?post=10975"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}