{"id":11052,"date":"2021-03-11T10:00:53","date_gmt":"2021-03-11T16:00:53","guid":{"rendered":"https:\/\/admin.acceleratingscience.com\/materials\/?p=11052"},"modified":"2025-11-24T07:32:48","modified_gmt":"2025-11-24T13:32:48","slug":"x-ray-diffraction-analysis-of-polymers","status":"publish","type":"post","link":"https:\/\/www.thermofisher.com\/blog\/materials\/x-ray-diffraction-analysis-of-polymers\/","title":{"rendered":"X-ray Diffraction Analysis of Polymers"},"content":{"rendered":"<h2 style=\"color:white;font-size:50%;height:5px\">Crystallinity in polymers and plastics<\/h2>\n<p>Plastics, a type of polymer, are used in almost every industry, from packaging and electronics to construction. Specific applications\u2014like water bottle caps and cell phone covers\u2014require different properties.<\/p>\n<p>Properties are determined by the degree of crystallization and by the type of polymer. Polymers are composed of long molecular chains, which range from highly crystalline structures like a box of uncooked spaghetti to amorphous structures with highly entangled coils like cooked spaghetti in a strainer.<\/p>\n<p>The crystallinity of a polymer defines its optical, mechanical, thermal, and chemical properties\u2014all which are important for achieving desired qualities in various applications. For example, high crystalline polymers are rigid, have high melting points, and are less affected by solvent penetration, whereas amorphous polymers are softer and more pliable, don\u2019t melt as quickly when heated, and are more susceptible to solvent penetration.<\/p>\n<h2 style=\"color:white;font-size:50%;height:5px\">X-ray diffraction methods in polymer science<\/h2>\n<p>As scientists analyze the suitability of plastics for their products, X-ray diffraction (XRD) has become the go-to tool for identifying the type and crystallinity of polymer materials. The <a href=\"https:\/\/www.thermofisher.com\/order\/catalog\/product\/IQLAAHGABLFAQLMBIX\">Thermo Scientific ARL EQUINOX 100 Benchtop X-ray Diffractometer<\/a>, in particular, provides expedited data collection times compared to other options\u2014thanks to its unique, curved position sensitive (CPS) detector that measures all diffraction peaks simultaneously in real time.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-11053 aligncenter\" src=\"https:\/\/admin.acceleratingscience.com\/materials\/wp-content\/uploads\/sites\/7\/2021\/03\/spec-blog-3_11_21.png\" alt=\"Polymer crystallinity determined with X-ray diffraction\" title=\"Polymer crystallinity determined with X-ray diffraction\" width=\"1087\" height=\"473\" srcset=\"https:\/\/admin.acceleratingscience.com\/materials\/wp-content\/uploads\/sites\/7\/2021\/03\/spec-blog-3_11_21.png 1087w, https:\/\/admin.acceleratingscience.com\/materials\/wp-content\/uploads\/sites\/7\/2021\/03\/spec-blog-3_11_21-300x131.png 300w, https:\/\/admin.acceleratingscience.com\/materials\/wp-content\/uploads\/sites\/7\/2021\/03\/spec-blog-3_11_21-1024x446.png 1024w, https:\/\/admin.acceleratingscience.com\/materials\/wp-content\/uploads\/sites\/7\/2021\/03\/spec-blog-3_11_21-768x334.png 768w\" sizes=\"auto, (max-width: 1087px) 100vw, 1087px\" \/><\/p>\n<p style=\"text-align: center\"><em>Using the ARL EQUINOX 100 X-ray Diffractometer, the degree of polymer crystallinity can be identified in minutes.<\/em><\/p>\n<p><em>\u00a0<\/em>With the ARL EQUINOX 100, researchers can determine the quality of polymer products\u2014both in research labs and during the production process\u2014in less than 10 minutes! The ARL EQUINOX 100 uses a high flux X-ray source with very low power consumption that doesn\u2019t require an external water chiller or other peripheral equipment, making it the most energy efficient XRD solution available.<\/p>\n<p>The compact benchtop design offers high-quality data comparable to that obtained from a typical high-power, floor-standing instrument. Used together with MDI JADE 2010 software and the ICDD PDF4+ Organic database, researchers of all experience levels can quickly determine the type and crystallinity of polymer materials.<\/p>\n<p>The ARL EQUINOX 100 offers today\u2019s busy industrial labs a fast and convenient way to analyze polymer compounds, helping them speed analyses and lower costs as they ensure the quality of polymer products.<\/p>\n<p>To learn more about how the ARL EQUINOX 100 Benchtop X-ray Diffractometer can be used for polymer research, please see our <a href=\"https:\/\/www.thermofisher.com\/us\/en\/home\/industrial\/spectroscopy-elemental-isotope-analysis\/materials-science-research\/polymer-analysis\/structural-analysis-polymers.html\">Structural Analysis of Polymers<\/a> webpage and download the <a href=\"https:\/\/www.thermofisher.com\/us\/en\/home\/global\/forms\/industrial\/scientific-poster-xrd-analysis-polymer-material.html\">Polymer Material Analysis poster.<\/a><\/p>\n<p><em>\u00a0<\/em><em>Dr. Simon Welzmiller is a Global Application Specialist XRD at Thermo Fisher Scientific.<\/em><\/p>\n<p><em>\u00a0<\/em>\/\/\/<\/p>\n<p><a href=\"http:\/\/www.acceleratingscience.com\/materials\/subscribe\/\">Subscribe now<\/a> to receive Advancing Materials updates straight to your inbox.<\/p>\n<p>Connect with an expert:\u00a0<a href=\"https:\/\/www.thermofisher.com\/us\/en\/home\/global\/forms\/industrial\/spectroscopy-materials-analysis-inquiries.html\">https:\/\/www.thermofisher.com\/us\/en\/home\/global\/forms\/industrial\/spectroscopy-materials-analysis-inquiries.html<\/a><\/p>\n","protected":false},"excerpt":{"rendered":"<p>Crystallinity in polymers and plastics Plastics, a type of polymer, are used in almost every industry, from packaging and electronics to construction. Specific applications\u2014like water bottle caps and cell phone covers\u2014require different properties. Properties are determined by the degree of crystallization and by the type of polymer. Polymers are composed of long molecular chains, which<\/p>\n","protected":false},"author":1282,"featured_media":11053,"comment_status":"open","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_monsterinsights_skip_tracking":false,"_genesis_hide_title":false,"_genesis_hide_breadcrumbs":false,"_genesis_hide_singular_image":false,"_genesis_hide_footer_widgets":false,"_genesis_custom_body_class":"","_genesis_custom_post_class":"","_genesis_layout":"","footnotes":""},"categories":[21,968,976],"tags":[955],"division":[],"class_list":["post-11052","post","type-post","status-publish","format-standard","has-post-thumbnail","category-quality-control-and-assurance-verification","category-spectroscopy-spectrometry","category-x-ray-diffraction","tag-polymer-plastics","entry"],"_selected_authors":[765],"_selected_reviewers":[],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v27.8 (Yoast SEO v27.8) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>X-ray Diffraction Analysis of Polymers - Advancing Materials<\/title>\n<meta name=\"description\" content=\"X-ray diffraction of polymers allows you to determine their crystallinity, defining the optical, mechanical, thermal, and chemical properties of plastics.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.thermofisher.com\/blog\/materials\/x-ray-diffraction-analysis-of-polymers\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"X-ray Diffraction Analysis of Polymers\" \/>\n<meta property=\"og:description\" content=\"X-ray diffraction of polymers allows you to determine their crystallinity, defining the optical, mechanical, thermal, and chemical properties of plastics.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.thermofisher.com\/blog\/materials\/x-ray-diffraction-analysis-of-polymers\/\" \/>\n<meta property=\"og:site_name\" content=\"Advancing Materials\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/thermofisher\" \/>\n<meta property=\"article:published_time\" content=\"2021-03-11T16:00:53+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2025-11-24T13:32:48+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/admin.acceleratingscience.com\/materials\/wp-content\/uploads\/sites\/7\/2021\/03\/spec-blog-3_11_21.png\" \/>\n\t<meta property=\"og:image:width\" content=\"1087\" \/>\n\t<meta property=\"og:image:height\" content=\"473\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/png\" \/>\n<meta name=\"author\" content=\"Simon Welzmiller\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:creator\" content=\"@thermofisher\" \/>\n<meta name=\"twitter:site\" content=\"@thermofisher\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Simon Welzmiller\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"3 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/materials\\\/x-ray-diffraction-analysis-of-polymers\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/materials\\\/x-ray-diffraction-analysis-of-polymers\\\/\"},\"author\":{\"name\":\"Simon Welzmiller\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/materials\\\/#\\\/schema\\\/person\\\/555c8966d36194e6ed3174e82f86f7fc\"},\"headline\":\"X-ray Diffraction Analysis of Polymers\",\"datePublished\":\"2021-03-11T16:00:53+00:00\",\"dateModified\":\"2025-11-24T13:32:48+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/materials\\\/x-ray-diffraction-analysis-of-polymers\\\/\"},\"wordCount\":445,\"commentCount\":2,\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/materials\\\/x-ray-diffraction-analysis-of-polymers\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/materials\\\/wp-content\\\/uploads\\\/sites\\\/7\\\/2021\\\/03\\\/spec-blog-3_11_21.png\",\"keywords\":[\"Polymer\\\/Plastics\"],\"articleSection\":[\"QA\\\/QC Verification\",\"Spectroscopy and Spectrometry\",\"X-Ray Diffraction\"],\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/materials\\\/x-ray-diffraction-analysis-of-polymers\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/materials\\\/x-ray-diffraction-analysis-of-polymers\\\/\",\"url\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/materials\\\/x-ray-diffraction-analysis-of-polymers\\\/\",\"name\":\"X-ray Diffraction Analysis of Polymers - Advancing Materials\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/materials\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/materials\\\/x-ray-diffraction-analysis-of-polymers\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/materials\\\/x-ray-diffraction-analysis-of-polymers\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/materials\\\/wp-content\\\/uploads\\\/sites\\\/7\\\/2021\\\/03\\\/spec-blog-3_11_21.png\",\"datePublished\":\"2021-03-11T16:00:53+00:00\",\"dateModified\":\"2025-11-24T13:32:48+00:00\",\"author\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/materials\\\/#\\\/schema\\\/person\\\/555c8966d36194e6ed3174e82f86f7fc\"},\"description\":\"X-ray diffraction of polymers allows you to determine their crystallinity, defining the optical, mechanical, thermal, and chemical properties of plastics.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/materials\\\/x-ray-diffraction-analysis-of-polymers\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/materials\\\/x-ray-diffraction-analysis-of-polymers\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/materials\\\/x-ray-diffraction-analysis-of-polymers\\\/#primaryimage\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/materials\\\/wp-content\\\/uploads\\\/sites\\\/7\\\/2021\\\/03\\\/spec-blog-3_11_21.png\",\"contentUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/materials\\\/wp-content\\\/uploads\\\/sites\\\/7\\\/2021\\\/03\\\/spec-blog-3_11_21.png\",\"width\":1087,\"height\":473},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/materials\\\/x-ray-diffraction-analysis-of-polymers\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/materials\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"X-ray Diffraction Analysis of Polymers\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/materials\\\/#website\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/materials\\\/\",\"name\":\"Advancing Materials\",\"description\":\"Spectroscopy, spectrometry, and materials science stories and solutions about advancing research and improving product development\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/materials\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/materials\\\/#\\\/schema\\\/person\\\/555c8966d36194e6ed3174e82f86f7fc\",\"name\":\"Simon Welzmiller\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/f3807d72ee8db451b81791a2948ec570150a7b7e2abca73a355086de8f09fe4c?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/f3807d72ee8db451b81791a2948ec570150a7b7e2abca73a355086de8f09fe4c?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/f3807d72ee8db451b81791a2948ec570150a7b7e2abca73a355086de8f09fe4c?s=96&d=mm&r=g\",\"caption\":\"Simon Welzmiller\"},\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/author\\\/simonwelzmiller\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"X-ray Diffraction Analysis of Polymers - Advancing Materials","description":"X-ray diffraction of polymers allows you to determine their crystallinity, defining the optical, mechanical, thermal, and chemical properties of plastics.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.thermofisher.com\/blog\/materials\/x-ray-diffraction-analysis-of-polymers\/","og_locale":"en_US","og_type":"article","og_title":"X-ray Diffraction Analysis of Polymers","og_description":"X-ray diffraction of polymers allows you to determine their crystallinity, defining the optical, mechanical, thermal, and chemical properties of plastics.","og_url":"https:\/\/www.thermofisher.com\/blog\/materials\/x-ray-diffraction-analysis-of-polymers\/","og_site_name":"Advancing Materials","article_publisher":"https:\/\/www.facebook.com\/thermofisher","article_published_time":"2021-03-11T16:00:53+00:00","article_modified_time":"2025-11-24T13:32:48+00:00","og_image":[{"width":1087,"height":473,"url":"https:\/\/admin.acceleratingscience.com\/materials\/wp-content\/uploads\/sites\/7\/2021\/03\/spec-blog-3_11_21.png","type":"image\/png"}],"author":"Simon Welzmiller","twitter_card":"summary_large_image","twitter_creator":"@thermofisher","twitter_site":"@thermofisher","twitter_misc":{"Written by":"Simon Welzmiller","Est. reading time":"3 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.thermofisher.com\/blog\/materials\/x-ray-diffraction-analysis-of-polymers\/#article","isPartOf":{"@id":"https:\/\/www.thermofisher.com\/blog\/materials\/x-ray-diffraction-analysis-of-polymers\/"},"author":{"name":"Simon Welzmiller","@id":"https:\/\/admin.acceleratingscience.com\/materials\/#\/schema\/person\/555c8966d36194e6ed3174e82f86f7fc"},"headline":"X-ray Diffraction Analysis of Polymers","datePublished":"2021-03-11T16:00:53+00:00","dateModified":"2025-11-24T13:32:48+00:00","mainEntityOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/materials\/x-ray-diffraction-analysis-of-polymers\/"},"wordCount":445,"commentCount":2,"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/materials\/x-ray-diffraction-analysis-of-polymers\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/materials\/wp-content\/uploads\/sites\/7\/2021\/03\/spec-blog-3_11_21.png","keywords":["Polymer\/Plastics"],"articleSection":["QA\/QC Verification","Spectroscopy and Spectrometry","X-Ray Diffraction"],"inLanguage":"en-US","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/www.thermofisher.com\/blog\/materials\/x-ray-diffraction-analysis-of-polymers\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/www.thermofisher.com\/blog\/materials\/x-ray-diffraction-analysis-of-polymers\/","url":"https:\/\/www.thermofisher.com\/blog\/materials\/x-ray-diffraction-analysis-of-polymers\/","name":"X-ray Diffraction Analysis of Polymers - Advancing Materials","isPartOf":{"@id":"https:\/\/admin.acceleratingscience.com\/materials\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/materials\/x-ray-diffraction-analysis-of-polymers\/#primaryimage"},"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/materials\/x-ray-diffraction-analysis-of-polymers\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/materials\/wp-content\/uploads\/sites\/7\/2021\/03\/spec-blog-3_11_21.png","datePublished":"2021-03-11T16:00:53+00:00","dateModified":"2025-11-24T13:32:48+00:00","author":{"@id":"https:\/\/admin.acceleratingscience.com\/materials\/#\/schema\/person\/555c8966d36194e6ed3174e82f86f7fc"},"description":"X-ray diffraction of polymers allows you to determine their crystallinity, defining the optical, mechanical, thermal, and chemical properties of plastics.","breadcrumb":{"@id":"https:\/\/www.thermofisher.com\/blog\/materials\/x-ray-diffraction-analysis-of-polymers\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.thermofisher.com\/blog\/materials\/x-ray-diffraction-analysis-of-polymers\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.thermofisher.com\/blog\/materials\/x-ray-diffraction-analysis-of-polymers\/#primaryimage","url":"https:\/\/admin.acceleratingscience.com\/materials\/wp-content\/uploads\/sites\/7\/2021\/03\/spec-blog-3_11_21.png","contentUrl":"https:\/\/admin.acceleratingscience.com\/materials\/wp-content\/uploads\/sites\/7\/2021\/03\/spec-blog-3_11_21.png","width":1087,"height":473},{"@type":"BreadcrumbList","@id":"https:\/\/www.thermofisher.com\/blog\/materials\/x-ray-diffraction-analysis-of-polymers\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/admin.acceleratingscience.com\/materials\/"},{"@type":"ListItem","position":2,"name":"X-ray Diffraction Analysis of Polymers"}]},{"@type":"WebSite","@id":"https:\/\/admin.acceleratingscience.com\/materials\/#website","url":"https:\/\/admin.acceleratingscience.com\/materials\/","name":"Advancing Materials","description":"Spectroscopy, spectrometry, and materials science stories and solutions about advancing research and improving product development","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/admin.acceleratingscience.com\/materials\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Person","@id":"https:\/\/admin.acceleratingscience.com\/materials\/#\/schema\/person\/555c8966d36194e6ed3174e82f86f7fc","name":"Simon Welzmiller","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/secure.gravatar.com\/avatar\/f3807d72ee8db451b81791a2948ec570150a7b7e2abca73a355086de8f09fe4c?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/f3807d72ee8db451b81791a2948ec570150a7b7e2abca73a355086de8f09fe4c?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/f3807d72ee8db451b81791a2948ec570150a7b7e2abca73a355086de8f09fe4c?s=96&d=mm&r=g","caption":"Simon Welzmiller"},"url":"https:\/\/admin.acceleratingscience.com\/author\/simonwelzmiller\/"}]}},"taxonomy_info":{"category":[{"value":21,"label":"QA\/QC Verification"},{"value":968,"label":"Spectroscopy and Spectrometry"},{"value":976,"label":"X-Ray Diffraction"}],"post_tag":[{"value":955,"label":"Polymer\/Plastics"}]},"featured_image_src_large":["https:\/\/admin.acceleratingscience.com\/materials\/wp-content\/uploads\/sites\/7\/2021\/03\/spec-blog-3_11_21-1024x446.png",760,331,true],"author_info":{"display_name":"Simon Welzmiller","author_link":"https:\/\/admin.acceleratingscience.com\/author\/simonwelzmiller\/"},"comment_info":2,"category_info":[{"term_id":21,"name":"QA\/QC Verification","slug":"quality-control-and-assurance-verification","term_group":0,"term_taxonomy_id":21,"taxonomy":"category","description":"","parent":0,"count":132,"filter":"raw","meta":[],"cat_ID":21,"category_count":132,"category_description":"","cat_name":"QA\/QC Verification","category_nicename":"quality-control-and-assurance-verification","category_parent":0},{"term_id":968,"name":"Spectroscopy and Spectrometry","slug":"spectroscopy-spectrometry","term_group":0,"term_taxonomy_id":968,"taxonomy":"category","description":"","parent":0,"count":222,"filter":"raw","meta":[],"cat_ID":968,"category_count":222,"category_description":"","cat_name":"Spectroscopy and Spectrometry","category_nicename":"spectroscopy-spectrometry","category_parent":0},{"term_id":976,"name":"X-Ray Diffraction","slug":"x-ray-diffraction","term_group":0,"term_taxonomy_id":976,"taxonomy":"category","description":"","parent":968,"count":23,"filter":"raw","meta":[],"cat_ID":976,"category_count":23,"category_description":"","cat_name":"X-Ray Diffraction","category_nicename":"x-ray-diffraction","category_parent":968}],"tag_info":[{"term_id":955,"name":"Polymer\/Plastics","slug":"polymer-plastics","term_group":0,"term_taxonomy_id":955,"taxonomy":"post_tag","description":"","parent":0,"count":221,"filter":"raw","meta":[]}],"_links":{"self":[{"href":"https:\/\/www.thermofisher.com\/blog\/materials\/wp-json\/wp\/v2\/posts\/11052","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.thermofisher.com\/blog\/materials\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.thermofisher.com\/blog\/materials\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/materials\/wp-json\/wp\/v2\/users\/1282"}],"replies":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/materials\/wp-json\/wp\/v2\/comments?post=11052"}],"version-history":[{"count":0,"href":"https:\/\/www.thermofisher.com\/blog\/materials\/wp-json\/wp\/v2\/posts\/11052\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/materials\/wp-json\/wp\/v2\/media\/11053"}],"wp:attachment":[{"href":"https:\/\/www.thermofisher.com\/blog\/materials\/wp-json\/wp\/v2\/media?parent=11052"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/materials\/wp-json\/wp\/v2\/categories?post=11052"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/materials\/wp-json\/wp\/v2\/tags?post=11052"},{"taxonomy":"division","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/materials\/wp-json\/wp\/v2\/division?post=11052"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}