{"id":11768,"date":"2021-05-13T08:00:56","date_gmt":"2021-05-13T13:00:56","guid":{"rendered":"https:\/\/admin.acceleratingscience.com\/materials\/?p=11768"},"modified":"2025-08-18T09:05:01","modified_gmt":"2025-08-18T14:05:01","slug":"how-gemology-tests-gemstones-for-authenticity","status":"publish","type":"post","link":"https:\/\/www.thermofisher.com\/blog\/materials\/how-gemology-tests-gemstones-for-authenticity\/","title":{"rendered":"How to Test Gemstones for Authenticity"},"content":{"rendered":"<p>Gemstones are a big business across the world. In 2018, <a href=\"https:\/\/africanminingmarket.com\/gemstones-market-is-expected-to-grow-at-a-cagr-of-5-over-2018-2026\/3811\/#:~:text=Gemstones%20Market%20is%20expected%20to%20grow%20at%20a,...%203%20Competition%20Analysis%3A%20Gemstones%20Market%20Players.%20\">$22 billion of gemstones were sold globally<\/a>, and the market continues to experience <a href=\"https:\/\/www.expertmarketresearch.com\/reports\/gemstones-market\">4.8 percent year-over-year growth<\/a>. X-ray fluorescence (EDXRF) is a valuable gemology tool used to determine the origin and authenticity of gemstones.<\/p>\n<p>As the demand for gemstone jewelry and ornaments continues, synthetic gemstones are driving part of this growth. How can you tell the difference between an authentic gemstone that forms naturally within the earth and a cheaper synthetic gemstone manufactured in a lab?<\/p>\n<p>To efficiently determine the authenticity of gemstones, gemology labs are turning to <a href=\"https:\/\/www.thermofisher.com\/uk\/en\/home\/industrial\/spectroscopy-elemental-isotope-analysis\/spectroscopy-elemental-isotope-analysis-learning-center\/elemental-structural-analysis-information\/xrf-academy.html?cid=7014z000000iIFR\">energy dispersive X-ray fluorescence<\/a> (EDXRF), a method widely used for the chemical analysis of materials. Using EDXRF, gemologists irradiate a gemstone sample with high-energy X-rays and collect the fluorescence radiation emitted to determine the elemental composition of the gemstone, including trace elements at different concentrations.<\/p>\n<p>EDXRF provides a fast, cost-effective, and non-destructive way to determine the authenticity of gemstones such as rubies, emeralds, and sapphires down to their location of origin\u2014whether that be Colombia, Brazil, Afghanistan, Zambia, Zimbabwe, or another country. By examining the presence of trace elements, researchers can distinguish between a valuable natural gemstone and a quasi-worthless one that\u2019s been synthetically manufactured.<\/p>\n<p>Using the <a href=\"https:\/\/www.thermofisher.com\/order\/catalog\/product\/IQLAAHGABMFAAWMACL?cid=7014z000000iIFR\">Thermo Scientific ARL QUANT\u2019X EDXRF Spectrometer<\/a>, for example, gemology labs can obtain compositional information about gemstones within minutes. By being mounted on a custom-made sample holder or placed in an XRF cup sealed with a 4-micron thick polypropylene film, gemstones can be analyzed without being damaged. The instrument is fitted with the latest-generation silicon drift detector, offering excellent sensitivity for the analysis of trace elements across the periodic table.\u00a0 Moreover, the compact footprint makes it easy to transport the spectrometer to wherever gemstone analyses are needed.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"wp-image-11769 aligncenter\" src=\"https:\/\/admin.acceleratingscience.com\/materials\/wp-content\/uploads\/sites\/7\/2021\/05\/gemstones.jpg\" alt=\"Various gemstones whose authenticity can be assessed with EDXRF gemology\" width=\"540\" height=\"367\" srcset=\"https:\/\/admin.acceleratingscience.com\/materials\/wp-content\/uploads\/sites\/7\/2021\/05\/gemstones.jpg 837w, https:\/\/admin.acceleratingscience.com\/materials\/wp-content\/uploads\/sites\/7\/2021\/05\/gemstones-300x204.jpg 300w, https:\/\/admin.acceleratingscience.com\/materials\/wp-content\/uploads\/sites\/7\/2021\/05\/gemstones-768x522.jpg 768w, https:\/\/admin.acceleratingscience.com\/materials\/wp-content\/uploads\/sites\/7\/2021\/05\/gemstones-96x65.jpg 96w\" sizes=\"auto, (max-width: 540px) 100vw, 540px\" \/><\/p>\n<p style=\"text-align: center\"><em>The Thermo Scientific ARL QUANT\u2019X EDXRF Spectrometer offers a fast, cost-effective, and non-destructive way to determine the authenticity and geographical origin of colored gemstones.<\/em><\/p>\n<p>With the ARL QUANT\u2019X EDXRF Spectrometer, gemological labs can obtain measurements comparable to those of a Laser Ablation Inductively Coupled Plasma Mass Spectrometer\u2014a semi-destructive analysis technique often used as a reference for gemstone analysis\u2014without damaging their gemstone sample.<\/p>\n<p>As the market for gemstones continues to grow, EDXRF is an important technique for establishing the value of these precious stones. With the ARL QUANT\u2019X EDXRF Spectrometer, gemologists can quickly and non-destructively quantify their elemental composition, determining the authenticity and geographic origin of a wide variety of gemstones prized by cultures around the globe.<\/p>\n<p>To learn more, see our application note about <a href=\"https:\/\/assets.thermofisher.com\/TFS-Assets\/MSD\/Application-Notes\/XRF-AN41958-authenticity-gemstones-edxrf.pdf?cid=7014z000000iIFR\">determining the origin and authenticity of gemstones with ARL QUANT\u2019X EDXRF Spectrometer<\/a>.<\/p>\n<p><em>Pascal Lemberge is an Application Specialist for EDXRF at Thermo Fisher Scientific. <\/em><\/p>\n<p>\/\/<\/p>\n<p>Connect with an expert:\u00a0<a href=\"https:\/\/www.thermofisher.com\/uk\/en\/home\/global\/forms\/industrial\/spectroscopy-materials-analysis-inquiries.html?cid=7014z000000iIFR\">https:\/\/www.thermofisher.com\/us\/en\/home\/global\/forms\/industrial\/spectroscopy-materials-analysis-inquiries.html<\/a><\/p>\n","protected":false},"excerpt":{"rendered":"<p>Gemstones are a big business across the world. In 2018, $22 billion of gemstones were sold globally, and the market continues to experience 4.8 percent year-over-year growth. X-ray fluorescence (EDXRF) is a valuable gemology tool used to determine the origin and authenticity of gemstones. As the demand for gemstone jewelry and ornaments continues, synthetic gemstones<\/p>\n","protected":false},"author":42,"featured_media":11769,"comment_status":"open","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_monsterinsights_skip_tracking":false,"_genesis_hide_title":false,"_genesis_hide_breadcrumbs":false,"_genesis_hide_singular_image":false,"_genesis_hide_footer_widgets":false,"_genesis_custom_body_class":"","_genesis_custom_post_class":"","_genesis_layout":"","footnotes":""},"categories":[978,21,968],"tags":[947,951],"division":[],"class_list":{"0":"post-11768","1":"post","2":"type-post","3":"status-publish","4":"format-standard","5":"has-post-thumbnail","7":"category-fluorescence","8":"category-quality-control-and-assurance-verification","9":"category-spectroscopy-spectrometry","10":"tag-geology","11":"tag-mining","12":"entry"},"_selected_authors":[771],"_selected_reviewers":[],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v27.8 (Yoast SEO v27.8) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>X-Ray Fluorescence - EDXRF - Gemology - Advancing Materials<\/title>\n<meta name=\"description\" content=\"Energy dispersive X-ray fluorescence (EDXRF) is a valuable gemology tool used to determine the origin and authenticity of gemstones.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.thermofisher.com\/blog\/materials\/how-gemology-tests-gemstones-for-authenticity\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"How to Test Gemstones for Authenticity\" \/>\n<meta property=\"og:description\" content=\"Energy dispersive X-ray fluorescence (EDXRF) is a valuable gemology tool used to determine the origin and authenticity of gemstones.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.thermofisher.com\/blog\/materials\/how-gemology-tests-gemstones-for-authenticity\/\" \/>\n<meta property=\"og:site_name\" content=\"Advancing Materials\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/thermofisher\" \/>\n<meta property=\"article:published_time\" content=\"2021-05-13T13:00:56+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2025-08-18T14:05:01+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/admin.acceleratingscience.com\/materials\/wp-content\/uploads\/sites\/7\/2021\/05\/gemstones.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"837\" \/>\n\t<meta property=\"og:image:height\" content=\"569\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"Pascal Lemberge\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:creator\" content=\"@thermofisher\" \/>\n<meta name=\"twitter:site\" content=\"@thermofisher\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Pascal Lemberge\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"3 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/materials\\\/how-gemology-tests-gemstones-for-authenticity\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/materials\\\/how-gemology-tests-gemstones-for-authenticity\\\/\"},\"author\":{\"name\":\"Pascal Lemberge\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/materials\\\/#\\\/schema\\\/person\\\/3f5303684ff2330e3dd813cf7fa60877\"},\"headline\":\"How to Test Gemstones for Authenticity\",\"datePublished\":\"2021-05-13T13:00:56+00:00\",\"dateModified\":\"2025-08-18T14:05:01+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/materials\\\/how-gemology-tests-gemstones-for-authenticity\\\/\"},\"wordCount\":466,\"commentCount\":1,\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/materials\\\/how-gemology-tests-gemstones-for-authenticity\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/materials\\\/wp-content\\\/uploads\\\/sites\\\/7\\\/2021\\\/05\\\/gemstones.jpg\",\"keywords\":[\"Geology\",\"Mining\"],\"articleSection\":[\"Fluorescence\",\"QA\\\/QC Verification\",\"Spectroscopy and Spectrometry\"],\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/materials\\\/how-gemology-tests-gemstones-for-authenticity\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/materials\\\/how-gemology-tests-gemstones-for-authenticity\\\/\",\"url\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/materials\\\/how-gemology-tests-gemstones-for-authenticity\\\/\",\"name\":\"X-Ray Fluorescence - EDXRF - Gemology - Advancing Materials\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/materials\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/materials\\\/how-gemology-tests-gemstones-for-authenticity\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/materials\\\/how-gemology-tests-gemstones-for-authenticity\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/materials\\\/wp-content\\\/uploads\\\/sites\\\/7\\\/2021\\\/05\\\/gemstones.jpg\",\"datePublished\":\"2021-05-13T13:00:56+00:00\",\"dateModified\":\"2025-08-18T14:05:01+00:00\",\"author\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/materials\\\/#\\\/schema\\\/person\\\/3f5303684ff2330e3dd813cf7fa60877\"},\"description\":\"Energy dispersive X-ray fluorescence (EDXRF) is a valuable gemology tool used to determine the origin and authenticity of gemstones.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/materials\\\/how-gemology-tests-gemstones-for-authenticity\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/materials\\\/how-gemology-tests-gemstones-for-authenticity\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/materials\\\/how-gemology-tests-gemstones-for-authenticity\\\/#primaryimage\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/materials\\\/wp-content\\\/uploads\\\/sites\\\/7\\\/2021\\\/05\\\/gemstones.jpg\",\"contentUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/materials\\\/wp-content\\\/uploads\\\/sites\\\/7\\\/2021\\\/05\\\/gemstones.jpg\",\"width\":837,\"height\":569},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/materials\\\/how-gemology-tests-gemstones-for-authenticity\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/materials\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"How to Test Gemstones for Authenticity\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/materials\\\/#website\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/materials\\\/\",\"name\":\"Advancing Materials\",\"description\":\"Spectroscopy, spectrometry, and materials science stories and solutions about advancing research and improving product development\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/materials\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/materials\\\/#\\\/schema\\\/person\\\/3f5303684ff2330e3dd813cf7fa60877\",\"name\":\"Pascal Lemberge\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/c1de52ece21eea3f24124b9a1ae87a1384f39f8afa5b6816b73a812a159a658a?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/c1de52ece21eea3f24124b9a1ae87a1384f39f8afa5b6816b73a812a159a658a?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/c1de52ece21eea3f24124b9a1ae87a1384f39f8afa5b6816b73a812a159a658a?s=96&d=mm&r=g\",\"caption\":\"Pascal Lemberge\"},\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/author\\\/pascal-lembergethermofisher-com\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"X-Ray Fluorescence - EDXRF - Gemology - Advancing Materials","description":"Energy dispersive X-ray fluorescence (EDXRF) is a valuable gemology tool used to determine the origin and authenticity of gemstones.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.thermofisher.com\/blog\/materials\/how-gemology-tests-gemstones-for-authenticity\/","og_locale":"en_US","og_type":"article","og_title":"How to Test Gemstones for Authenticity","og_description":"Energy dispersive X-ray fluorescence (EDXRF) is a valuable gemology tool used to determine the origin and authenticity of gemstones.","og_url":"https:\/\/www.thermofisher.com\/blog\/materials\/how-gemology-tests-gemstones-for-authenticity\/","og_site_name":"Advancing Materials","article_publisher":"https:\/\/www.facebook.com\/thermofisher","article_published_time":"2021-05-13T13:00:56+00:00","article_modified_time":"2025-08-18T14:05:01+00:00","og_image":[{"width":837,"height":569,"url":"https:\/\/admin.acceleratingscience.com\/materials\/wp-content\/uploads\/sites\/7\/2021\/05\/gemstones.jpg","type":"image\/jpeg"}],"author":"Pascal Lemberge","twitter_card":"summary_large_image","twitter_creator":"@thermofisher","twitter_site":"@thermofisher","twitter_misc":{"Written by":"Pascal Lemberge","Est. reading time":"3 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.thermofisher.com\/blog\/materials\/how-gemology-tests-gemstones-for-authenticity\/#article","isPartOf":{"@id":"https:\/\/www.thermofisher.com\/blog\/materials\/how-gemology-tests-gemstones-for-authenticity\/"},"author":{"name":"Pascal Lemberge","@id":"https:\/\/admin.acceleratingscience.com\/materials\/#\/schema\/person\/3f5303684ff2330e3dd813cf7fa60877"},"headline":"How to Test Gemstones for Authenticity","datePublished":"2021-05-13T13:00:56+00:00","dateModified":"2025-08-18T14:05:01+00:00","mainEntityOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/materials\/how-gemology-tests-gemstones-for-authenticity\/"},"wordCount":466,"commentCount":1,"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/materials\/how-gemology-tests-gemstones-for-authenticity\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/materials\/wp-content\/uploads\/sites\/7\/2021\/05\/gemstones.jpg","keywords":["Geology","Mining"],"articleSection":["Fluorescence","QA\/QC Verification","Spectroscopy and Spectrometry"],"inLanguage":"en-US","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/www.thermofisher.com\/blog\/materials\/how-gemology-tests-gemstones-for-authenticity\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/www.thermofisher.com\/blog\/materials\/how-gemology-tests-gemstones-for-authenticity\/","url":"https:\/\/www.thermofisher.com\/blog\/materials\/how-gemology-tests-gemstones-for-authenticity\/","name":"X-Ray Fluorescence - EDXRF - Gemology - Advancing Materials","isPartOf":{"@id":"https:\/\/admin.acceleratingscience.com\/materials\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/materials\/how-gemology-tests-gemstones-for-authenticity\/#primaryimage"},"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/materials\/how-gemology-tests-gemstones-for-authenticity\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/materials\/wp-content\/uploads\/sites\/7\/2021\/05\/gemstones.jpg","datePublished":"2021-05-13T13:00:56+00:00","dateModified":"2025-08-18T14:05:01+00:00","author":{"@id":"https:\/\/admin.acceleratingscience.com\/materials\/#\/schema\/person\/3f5303684ff2330e3dd813cf7fa60877"},"description":"Energy dispersive X-ray fluorescence (EDXRF) is a valuable gemology tool used to determine the origin and authenticity of gemstones.","breadcrumb":{"@id":"https:\/\/www.thermofisher.com\/blog\/materials\/how-gemology-tests-gemstones-for-authenticity\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.thermofisher.com\/blog\/materials\/how-gemology-tests-gemstones-for-authenticity\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.thermofisher.com\/blog\/materials\/how-gemology-tests-gemstones-for-authenticity\/#primaryimage","url":"https:\/\/admin.acceleratingscience.com\/materials\/wp-content\/uploads\/sites\/7\/2021\/05\/gemstones.jpg","contentUrl":"https:\/\/admin.acceleratingscience.com\/materials\/wp-content\/uploads\/sites\/7\/2021\/05\/gemstones.jpg","width":837,"height":569},{"@type":"BreadcrumbList","@id":"https:\/\/www.thermofisher.com\/blog\/materials\/how-gemology-tests-gemstones-for-authenticity\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/admin.acceleratingscience.com\/materials\/"},{"@type":"ListItem","position":2,"name":"How to Test Gemstones for Authenticity"}]},{"@type":"WebSite","@id":"https:\/\/admin.acceleratingscience.com\/materials\/#website","url":"https:\/\/admin.acceleratingscience.com\/materials\/","name":"Advancing Materials","description":"Spectroscopy, spectrometry, and materials science stories and solutions about advancing research and improving product development","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/admin.acceleratingscience.com\/materials\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Person","@id":"https:\/\/admin.acceleratingscience.com\/materials\/#\/schema\/person\/3f5303684ff2330e3dd813cf7fa60877","name":"Pascal Lemberge","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/secure.gravatar.com\/avatar\/c1de52ece21eea3f24124b9a1ae87a1384f39f8afa5b6816b73a812a159a658a?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/c1de52ece21eea3f24124b9a1ae87a1384f39f8afa5b6816b73a812a159a658a?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/c1de52ece21eea3f24124b9a1ae87a1384f39f8afa5b6816b73a812a159a658a?s=96&d=mm&r=g","caption":"Pascal Lemberge"},"url":"https:\/\/admin.acceleratingscience.com\/author\/pascal-lembergethermofisher-com\/"}]}},"taxonomy_info":{"category":[{"value":978,"label":"Fluorescence"},{"value":21,"label":"QA\/QC Verification"},{"value":968,"label":"Spectroscopy and Spectrometry"}],"post_tag":[{"value":947,"label":"Geology"},{"value":951,"label":"Mining"}]},"featured_image_src_large":["https:\/\/admin.acceleratingscience.com\/materials\/wp-content\/uploads\/sites\/7\/2021\/05\/gemstones.jpg",760,517,false],"author_info":{"display_name":"Pascal Lemberge","author_link":"https:\/\/admin.acceleratingscience.com\/author\/pascal-lembergethermofisher-com\/"},"comment_info":1,"category_info":[{"term_id":978,"name":"Fluorescence","slug":"fluorescence","term_group":0,"term_taxonomy_id":978,"taxonomy":"category","description":"","parent":968,"count":28,"filter":"raw","meta":[],"cat_ID":978,"category_count":28,"category_description":"","cat_name":"Fluorescence","category_nicename":"fluorescence","category_parent":968},{"term_id":21,"name":"QA\/QC Verification","slug":"quality-control-and-assurance-verification","term_group":0,"term_taxonomy_id":21,"taxonomy":"category","description":"","parent":0,"count":132,"filter":"raw","meta":[],"cat_ID":21,"category_count":132,"category_description":"","cat_name":"QA\/QC Verification","category_nicename":"quality-control-and-assurance-verification","category_parent":0},{"term_id":968,"name":"Spectroscopy and Spectrometry","slug":"spectroscopy-spectrometry","term_group":0,"term_taxonomy_id":968,"taxonomy":"category","description":"","parent":0,"count":222,"filter":"raw","meta":[],"cat_ID":968,"category_count":222,"category_description":"","cat_name":"Spectroscopy and Spectrometry","category_nicename":"spectroscopy-spectrometry","category_parent":0}],"tag_info":[{"term_id":947,"name":"Geology","slug":"geology","term_group":0,"term_taxonomy_id":947,"taxonomy":"post_tag","description":"","parent":0,"count":4,"filter":"raw","meta":[]},{"term_id":951,"name":"Mining","slug":"mining","term_group":0,"term_taxonomy_id":951,"taxonomy":"post_tag","description":"","parent":0,"count":5,"filter":"raw","meta":[]}],"_links":{"self":[{"href":"https:\/\/www.thermofisher.com\/blog\/materials\/wp-json\/wp\/v2\/posts\/11768","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.thermofisher.com\/blog\/materials\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.thermofisher.com\/blog\/materials\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/materials\/wp-json\/wp\/v2\/users\/42"}],"replies":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/materials\/wp-json\/wp\/v2\/comments?post=11768"}],"version-history":[{"count":0,"href":"https:\/\/www.thermofisher.com\/blog\/materials\/wp-json\/wp\/v2\/posts\/11768\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/materials\/wp-json\/wp\/v2\/media\/11769"}],"wp:attachment":[{"href":"https:\/\/www.thermofisher.com\/blog\/materials\/wp-json\/wp\/v2\/media?parent=11768"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/materials\/wp-json\/wp\/v2\/categories?post=11768"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/materials\/wp-json\/wp\/v2\/tags?post=11768"},{"taxonomy":"division","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/materials\/wp-json\/wp\/v2\/division?post=11768"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}